FCC Warning

This equipment has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user’s guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

CE Mark Warning

This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

REVISION

User’s manual for PLANET Intelligent Media Converter Chassis

For ModelsWMC-1600R, WMC-1600R48

Rev 1.0 (Dec. 2002)

Part No. EM-WMCv1

Page 4 of the Planet Technology 170S8FS user manual — 1.2 Features
Page 4 · click to enlarge
Page 4

Chapter 1 Introduction

1.1 Briefing

The Intelligent Media Converter Chassis WMC-1600R series provides 16-slot and one management system in the 19”-rack chassis. The management function enable network administrator to monitor the media converter connection status and configure the converter via SNMP agent, Telnet and Web remotely or via RS-232 console port, yet eases the maintenance of media conversion.

The WMC-1600R series media converter chassis allows the connectivity of up to sixteen PLANET Smart Fast / Gigabit Ethernet Converter in one chassis. With the independent power supply on each slot of the WMC-1600R series, you can freely install or remove the converters without interrupting the rest of the networks. Moreover, it’s very flexible that each bay of the media converter chassis can be deployed with PLANET’s smart media converter family. Redundant power supply is also provided to enhance the reliability with option of either 100~240V AC power or -48V DC power.

1.2 Features

  • High quality 19” Rack-Mountable Chassis installation
  • Supports up to sixteen slide-in modular media converters hot-swappable
  • Two power slots for redundant power support with options of 100~240V AC or -48V DC
  • Reduce the effort of converter maintenance and management, diagnose the status at one
  • Two fans brings the air-flow for system cooling, and LED indicators for system and fan
  • Bay power isolation ensure each bay is electrically isolated from each other
  • Support PLANET smart series Fast Ethernet and Gigabit Ethernet Media Converter
  • One 10/100Mbps Fast Ethernet port and one RS-232 port for management
  • Configurable through console, Telnet and Web and SNMP
  • Provide the status of power, fan and converters with SNMP trap function for any chassis and

connectivity events.

time · status

Page 5 of the Planet Technology 170S8FS user manual — Chapter 1 Introduction
Page 5 · click to enlarge
Page 5
Page 5 of the Planet Technology 170S8FS user manual — Chapter 1 Introduction
Page 6 of the Planet Technology 170S8FS user manual — 2.3 Deciding How to Install the System
Page 6 · click to enlarge
Page 6

Chapter 2 UNPACKING AND INSTALL

This chapter provides unpacking and setup information for the Media Converter Chassis.

2.1 Unpacking

Open the box of the WMC-1600R and carefully unpack it. The box should contain the following items:

  • One Intelligent Media Converter Chassis with one power supply installed
  • One RS-232 Cable
  • One Power Cord
  • CD-ROM
  • Rack mounting Kit
  • This User’s Manual

If any item is found missing or damaged, please contact your local reseller for replacement.

2.2 Installation

The site where you place the chassis system may greatly affect its performance. When installing, take the following into your consideration:

As with any electric device, you should place the equipment where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:

- The ambient temperature should be between 32 and 104 degrees Fahrenheit (0 to 40

degrees Celsius).

- The relative humidity should be less than 90 percent, non?condensing.

- Surrounding electrical devices should not exceed the electromagnetic field (RFC)

standards for IEC 801?3, Level 2 (3V/M) field strength.

- Make sure that the equipment receives adequate ventilation at the rear. Do not block the

fan exhaust holes on the rear of the chassis.

- The power outlet should be within 1.8 meters of the chassis.

2.3 Deciding How to Install the System

We strongly suggest that you install the chassis first, as this is more convenient for you to install media converters into the chassis with ease. The accessories supplied in the product package include: rack-mount screws (8 pcs) and rack-mount brackets (2 pcs). This well-built chassis can be installed in the following ways:

Page 7 of the Planet Technology 170S8FS user manual — 2.3.2 Installing Media Converter
Page 7 · click to enlarge
Page 7

2.3.1 Mounted to 19-inch standard rack

Use the rack-mount brackets and screws to install the chassis into any EIA 19" standard rack.

1. Attach the brackets to each side of the chassis. Apply four screws to each side

and secure them tightly.

Planet Technology 170S8FS — 2.3.1 Mounted to 19-inch standard rack diagram (page 7)
Fig. 2 · 2.3.1 Mounted to 19-inch standard rack
2. Carefully position the chassis into the rack. Align the brackets to the side holes on the rack and use rack screws to secure the chassis with the rack.
Planet Technology 170S8FS — 2.3.1 Mounted to 19-inch standard rack diagram (page 7)
Fig. 3 · 2.3.1 Mounted to 19-inch standard rack
3. Proceed to the “Connecting to Power” section.

2.3.2 Installing Media Converter

The chassis is equipped with sixteen media converter carriers, each of which is fitted into bays of the chassis.

1. To install a media converter module onto the chassis, you have to unscrew the bay cover from the desired bay first.
2. Unscrew the hand screw counter clockwise by using hand or screwdriver and pull out the media converter out the carrier as shown below.
Planet Technology 170S8FS — 2.3.2 Installing Media Converter diagram (page 7)
Fig. 4 · 2.3.2 Installing Media Converter

Unscrew the hand screw counter clockwise by using hand or screwdriver and pull the media converter module out on the carrier

Page 8 of the Planet Technology 170S8FS user manual — 2.3.3 Connecting to Power (Power Supply)
Page 8 · click to enlarge
Page 8
3. Carefully slide in the module and fasten the hand screw clockwise by using hand or screwdriver until it is fully and firmly fitted into the slot of the chassis.
Planet Technology 170S8FS — 2.3.3 Connecting to Power (Power Supply) diagram (page 8)
Fig. 5 · 2.3.3 Connecting to Power (Power Supply)

Insert the media converter module into an available slot and fasten the hand screw clockwise by using hand or screwdriver.

2.3.3 Connecting to Power (Power Supply)

The chassis ships with only one power supply, and a second power supply option is at your discretion. When the chassis is equipped with two power supplies, you can have the following advanced performance.

The design of the power system is based on an idea of providing maximum flexibility and redundancy. In this way, you may remove any of the two power supplies without turning off the system.

During operation, both power supplies are switched on and share the current load. In case that one of them should fail, the other will instantaneously take 100% of the load without any loss. Similarly, if one power supply is removed from servicing, it can be switched off and removed while the chassis continues functioning.

The power of each converter bay comes from the two shared power supplies. Each bay is isolated from each other under a certain protection mechanism, so that it is free from any problem that might occur to the power supplies or faulty converter bay. This is the best solution to protect your investment in media converters.

Power Supply.

The chassis system is equipped with one power supply and allows one additional power supply for redundancy. For reliable operation, we suggest that you run the chassis system with two power supplies are in place.

1. Connect the supplied AC power cord to the back of the chassis.
2. Attach the plug into a standard AC outlet with a voltage range from 100~240

VAC.

3. Turn on the chassis system by flipping the switch beside the receptacle to ON

position. The LED on the front panel of power supply will come on then.

Hot Swappable – · Redundancy – · Protection System –

Page 9 of the Planet Technology 170S8FS user manual — 2.3.5 Power Notice:
Page 9 · click to enlarge
Page 9

2.3.4 Installing and Removing the Power Supply

To remove a power supply out the chassis, you have to loose the hand screw counter clockwise and pull out the power supply from the chassis.

To install a power supply to the chassis, you have to fasten the hand screw clockwise and slide in the power supply to the chassis.

Planet Technology 170S8FS — 2.3.4 Installing and Removing the Power Supply diagram (page 9)
Fig. 6 · 2.3.4 Installing and Removing the Power Supply

You can slide in and out the power supply from the bay, fasten or loose the hand screw clockwise or counter clockwise by using hand or screwdriver.

ber foot below the chassis!

2.3.5 Power Notice:

1.The device is a power-required device, it means, it will not work till it is powered. If your networks should active all the time, please consider using UPS (Uninterrupted Power Supply) for your device. It will prevent you from network data loss or network downtime.

2.In some area, installing a surge suppression device may also help to protect your switch from being damaged by unregulated surge or current to the media converter.

Page 10 of the Planet Technology 170S8FS user manual — 3.2 LED Indicators
Page 10 · click to enlarge
Page 10

Chapter 3 IDENTIFYING FRONT PANEL

This section identifies all the major components of the front panel. The front panel is shown, followed by a description of each panel feature. The indicator panel is described in detail in the next chapter.

3.1 Front Panel

The figure below shows the front panels of the Management Module.

The LED indicators of the Management Module include Power On, Power Fail, Fan Fail, MGM, Console and Link/ACT. The following shows the LED indicators for the Switch along with an explanation of each indicator.

  • LED Indicator Panel

Refer to the next section for detailed

Planet Technology 170S8FS — 3.1 Front Panel diagram (page 10)
Fig. 7 · 3.1 Front Panel

information.

  • Console Port (RS-232)

To configure the device through Terminal

Emulation Program via RS-232 serial

port.

  • 10/100Base-TX Port

To configure the device through

Web Browser or TELNET program via LAN

Ethernet.

3.2 LED Indicators

There are two powers at the rear and will indicate on the front panel the status of the power and fan:

PWR OnLights Greenwhen the power is inserted PWR FailLights Amberwhen the power is inserted and it is fail Fan FailLights Amberwhen the fan is fail to work MGMBlinks Greenwhen the device CPU is working Lights Amberwhen the CPU works fail ConsoleBlinks Greenwhen the data is transmitting Blinks Amberwhen transmitting the wrong data LNK/ACTLights Greenwhen link to networking Ethernet Blinks Greenwhen link is activity
Page 11 of the Planet Technology 170S8FS user manual — Chapter 3 IDENTIFYING FRONT PANEL
Page 11 · click to enlarge
Page 11
Page 11 of the Planet Technology 170S8FS user manual — Chapter 3 IDENTIFYING FRONT PANEL
Page 12 of the Planet Technology 170S8FS user manual — 4.1.2 TELNET program setting
Page 12 · click to enlarge
Page 12

Chapter 4 CONFIGURING THE SYSTEM

This chapter provides network managers and system administrators with information about how to configure the WMC-1600R via the Management interface.

4.1 Configure Through Terminal Emulator/TELNET Program

4.1.1 Console and Terminal Emulator program setting

The WMC-1600R can be accessible using a terminal or terminal emulator attached to the RS-232 serial port.

1.Locate correct DB9 serial port cable with female DB9 connector.

2.Attach the DB9 serial port female cable connector to the male DB9 serial port connector on the chassis system.

3.Attach the other end of the DB9 serial port cable to a remote the workstation.

4.By default, the Management Module uses the following serial port parameter values:

Bits per second 57600

The default Login name and password is both “root".

4.1.2 TELNET program setting

The WMC-1600R can be accessible using TELNET through LAN.

1. Run TELNET program.
2. Enter the IP address " 192.168.1.1 " (the factory-default IP address setting).
3. The default Login name and password is both " root ".
Show 4 more labels / short text on this page
Stop bits 1 · Data bits 8 · Parity NONE · Flow Control NONE
Page 13 of the Planet Technology 170S8FS user manual — 4.1.3.2 Configuration
Page 13 · click to enlarge
Page 13

4.1.3 Management Setting Through Terminal Emulator

There are three items in the Main Menu, System Function, Configuration and SNMP Configuration.

Planet Technology 170S8FS — 4.1.3 Management Setting Through Terminal Emulator diagram (page 13)
Fig. 8 · 4.1.3 Management Setting Through Terminal Emulator

4.1.3.1 System Function

There are three items in System Function menu, “Software Reboot, Factory Reset, and Image Update.

Planet Technology 170S8FS — 4.1.3.1 System Function diagram (page 13)
Fig. 9 · 4.1.3.1 System Function

4.1.3.1.1 Software Reboot

After configuring, it needs to reboot the software setting in order to run the device properly.

4.1.3.1.2 Factory Reset

This function is to set the device back to the default setting in case of the messy setting.

4.1.3.1.3 Image Update

Planet Technology 170S8FS — 4.1.3.1 System Function diagram (page 13)
Fig. 10 · 4.1.3.1 System Function

The section is to set the TFTP Server IP Address first, and the default address was set to “192.168.1.2”. The Image File can be updated by uploading the image file from the TFTP server.

agement module, please be sure that the image file is correct.

4.1.3.2 Configuration

To set the Software Reboot, Factory Reset and Image Update.

Planet Technology 170S8FS — 4.1.3.2 Configuration diagram (page 13)
Fig. 11 · 4.1.3.2 Configuration
Page 14 of the Planet Technology 170S8FS user manual — 4.1.3.2.1 General Configuration
Page 14 · click to enlarge
Page 14

There are four items in the Configuration menu, “General Configuration, System Configuration, Media Converter Chassis and Media Converters.

4.1.3.2.1 General Configuration

Planet Technology 170S8FS — 4.1.3.2.1 General Configuration diagram (page 14)
Fig. 12 · 4.1.3.2.1 General Configuration

Hardware revision: noted the version of the hardware.

BIOS revision: noted the version of the BIOS.

Firmware revision: noted the version of the firmware.

Change Password: the changing of the admit password.

Confirm Password: to confirm the setting of admit password.

System Name: to authorize the device system name.

Location: to show the device where it is located.

Refresh time: to set the refreshing time of the device through the web.

4.1.3.2.2 System Configuration

Planet Technology 170S8FS — 4.1.3.2.1 General Configuration diagram (page 14)
Fig. 13 · 4.1.3.2.1 General Configuration

MAC Address: will show out the MAC address of the device.

IP Address: to allocate an IP address for the device, the default IP is “192.168.1.1”.

Subnet Mask: to set the Subnet Mask, the default is “255.255.255.0”.

Default Gateway: to set the gateway address, the default is “192.168.1.254”.

save the setting.

Page 15 of the Planet Technology 170S8FS user manual — 4.1.3.2.3 Media Converter Chassis
Page 15 · click to enlarge
Page 15

4.1.3.2.3 Media Converter Chassis

Planet Technology 170S8FS — 4.1.3.2.3 Media Converter Chassis diagram (page 15)
Fig. 14 · 4.1.3.2.3 Media Converter Chassis

The screen will show out the power status of the WMC-1600R.

V stands for “yes” and X stands for “No”.

Plug in: indicates if Power 1 or 2 was plugged in or not.

Power Fail: indicates if the Power 1 or 2 is fail or not.

Fan Fail: indicates if the Fan 1 or 2 is fail or not.

4.1.3.2.4 Media Converters

Planet Technology 170S8FS — 4.1.3.2.3 Media Converter Chassis diagram (page 15)
Fig. 15 · 4.1.3.2.3 Media Converter Chassis

Indicates the Link, Duplex mode, Speed and Fail status of each media converter.

4.1.3.2.5 Media Converters Setting

Planet Technology 170S8FS — 4.1.3.2.3 Media Converter Chassis diagram (page 15)
Fig. 16 · 4.1.3.2.3 Media Converter Chassis

This screen is to set the Device function of LLCF and Link Enable; the Media 1 LLR function, Auto-Negotiation, Speed, Duplex Mode, Flow Control and Link Enable; the Media 2 LLR function, Auto-Negotiation, Duplex mode and Link Enable.

The “*” in the screen stands for N/A (not available), and the management interface will detect if the slot has the function in it and will let you set the function exist on the media converter slot.

Select the slot and press the space bar button to choose which function to open up.

Page 16 of the Planet Technology 170S8FS user manual — 4.1.3.2.6 Redundant Backup Setting
Page 16 · click to enlarge
Page 16

LLCF: Link Loss Carry Forward, “on” or “off”.

Enable: to enable the link of the Device, “on” or “off”.

LLR: Link Loss Return, “on” or “off”.

Auto: “A” for Auto-Negotiation or “F” for “forced Mode”.

Speed: to select the speed of the copper port, “10M”, “100M” or “1G”.

Dup: Duplex mode, “F” for Full Duplex or “H” for Half Duplex.

FC: Flow Control, “on” or “off”.

Enable: to enable the link of the Media 1, “on” or “off”.

LLR: Link Loss Return, “on” or “off”.

Auto: “A” for Auto-Negotiation or “F” for “forced Mode”.

Dup: Duplex mode, “F” for Full Duplex or “H” for Half Duplex.

Enable: to enable the link of the Media 1, “on” or “off”.

4.1.3.2.6 Redundant Backup Setting

Planet Technology 170S8FS — 4.1.3.2.6 Redundant Backup Setting diagram (page 16)
Fig. 17 · 4.1.3.2.6 Redundant Backup Setting

The redundant function is to change the master line to the slave line in case of the linking fails happen.

The Redundant functions were set fixed, the master slot is slot 1 (odd number slot) and the slave slot is slot 2 (even number slot), and there are eight redundant groups in all. The “Act” will indicate what slot is active.

When the slave slot is active, and we need to transfer again to the master slot, push on the restart button.

Show 4 more labels / short text on this page
Device · Media 1 · Media 2 · Converter
Page 17 of the Planet Technology 170S8FS user manual — 4.1.3.3 SNMP Configuration
Page 17 · click to enlarge
Page 17

4.1.3.3 SNMP Configuration

Planet Technology 170S8FS — 4.1.3.3 SNMP Configuration diagram (page 17)
Fig. 18 · 4.1.3.3 SNMP Configuration

Get Community Name: to get the device community name (default = public).

Set Community Name: to set the device community name (default = private).

Trap Community Name: to authorize the device trap community name (default = public).

Trap Host IP Address: to set the trap host IP address (same as monitoring station IP address).

Cold Start trap: to set the trap for rebooting the device (default = enable).

Warm Start trap: to set the trap when the device had been reset (default = enable).

Authentication Fail Trap: to set the warning trap when the community name of the device and workstation are different (default = enable).

Power Fail Trap: to set the Power Fail Trap (default = enable).

Fan Fail Trap: to set the fan fail trap (default = enable).

MC Plug-in Trap: to set the trap when a Media Converter module has been plugged in (default = enable).

MC Pullout Trap: to set the trap when the Media Converter module has been pulled out (default = enable).

MC Broken trap: to set the trap when the Media Converter module was broken (default = enable).

MC Link up trap: to set the trap when a linking is connected (default = enable).

MC Link down trap: to set the trap when a linking is disconnected (default = enable).

MC Active Slot Xchg trap: to set the trap when there is a redundant function activated (default = enable).

MC Active Slot Lose trap: to set the trap when the redundant function is fail (default = enable).

Page 18 of the Planet Technology 170S8FS user manual — 4.2 Management through Web browser
Page 18 · click to enlarge
Page 18

4.2 Management through Web browser

The WMC-1600R is accessible using a Web browser (IE explorer, Netscape Communications, etc.) to open up the chassis monitoring system. The default IP Address for the chassis system is “192.168.1.1”, and the default Login name and password is both “root”.

After enter its web interface, the Home Page will show out the page for general configuration. To set the management system, click on the left side menu, System Function and Configuration, the center screen will then show the status and configuration screen for the menu you clicked on the left side.

Planet Technology 170S8FS — 4.2 Management through Web browser diagram (page 18)
Fig. 19 · 4.2 Management through Web browser

Click on the Media Converter slot and it will appear a screen for you to monitor or control, depend on what media converter you are using.

Planet Technology 170S8FS — 4.2 Management through Web browser diagram (page 18)
Fig. 20 · 4.2 Management through Web browser
Page 19 of the Planet Technology 170S8FS user manual — 4.2.2.1 General Configuration
Page 19 · click to enlarge
Page 19

4.2.1 System Function

There are four items in System Function menu, “Software Reboot, Factory Reset, Image Update and Configuration Update.

4.2.1.1 Software Reboot

Reboot the management module in order to run the new setting properly.

4.2.1.2 Factory Reset

This function is to set the device back to the default setting in case of the messy setting.

4.2.1.3 Image Update

The section is to set the TFTP Server IP Address first, and the default address was set to “192.168.1.2”. The Image File can be updated by uploading the image file from the TFTP server.

agement interface, please be sure that the image file is correct.

4.2.1.4 Configuration Update

The section is explaining how to upload and download the configure setting of the management interface. The Configuration Upload is to restore a setting file to the management interface. The Configuration Download is to backup the setting from the management interface.

4.2.2 Configuration

There are five items in Configuration menu, General Configuration, System Configuration, SNMP Configuration, Location Setting and Redundant Backup Setting.

4.2.2.1 General Configuration

Planet Technology 170S8FS — 4.2.2.1 General Configuration diagram (page 19)
Fig. 21 · 4.2.2.1 General Configuration

Hardware revision: noted the version of the WMC-1600R.

BIOS revision: noted the version of the BIOS.

Firmware revision: noted the version of the firmware.

Change Password: the changing of the administrator password.

Confirm Password: to confirm the setting of administrator password.

Page 20 of the Planet Technology 170S8FS user manual — 4.2.2.3 SNMP Configuration
Page 20 · click to enlarge
Page 20

System Name: to authorize the device system name.

Location: to show the WMC-1600R where it is located.

Refresh time: to set the refreshing time of the device through the web.

save the setting.

4.2.2.2 System Configuration

Planet Technology 170S8FS — 4.2.2.2 System Configuration diagram (page 20)
Fig. 22 · 4.2.2.2 System Configuration

MAC Address: will show out the MAC address of the Management interface.

IP Address: to allocate an IP address for the Management interface, the default IP is “192.168.1.1”.

Subnet Mask: to set the Subnet Mask, the default is 255.255.255.0”.

Default Gateway: to set the gateway address, the default is “192.168.1.254”.

save the setting.

4.2.2.3 SNMP Configuration

Planet Technology 170S8FS — 4.2.2.3 SNMP Configuration diagram (page 20)
Fig. 23 · 4.2.2.3 SNMP Configuration

Get Community Name: to get the device community name (default = public).

Set Community Name: to set the device community name (default = private).

Trap Community Name: to authorize the device trap community name (default = public).

Trap Host IP Address: to set the trap host IP address (same as monitoring station IP address).

Cold Start trap: to set the trap for rebooting the device (default = enable).

Page 21 of the Planet Technology 170S8FS user manual — 4.2.2.4 Location Setting
Page 21 · click to enlarge
Page 21

Warm Start trap: to set the trap when the device had been reset (default = enable).

Authentication Fail Trap: to set the warning trap when the community name of the device and workstation are different (default = enable).

Power Fail Trap: to set the Power Fail Trap (default = enable).

Fan Fail Trap: to set the Fan fail trap (default = enable).

MC Plug-in Trap: to set the trap when a Media Converter Module has been plugged in (default = enable).

MC Pullout Trap: to set the trap when the Media Converter Module has been pulled out (default = enable).

MC Broken trap: to set the trap when the Media Converter Module was broken (default = enable).

MC Link up trap: to set the trap when a linking is connected (default = enable).

MC Link down trap: to set the trap when a linking is disconnected (default = enable).

MC Active Slot Xchg trap: to set the trap when there is a redundant function activated (default = enable).

MC Active Slot Lose trap: to set the trap when the redundant function is fail (default = enable).

4.2.2.4 Location Setting

Planet Technology 170S8FS — 4.2.2.4 Location Setting diagram (page 21)
Fig. 24 · 4.2.2.4 Location Setting

Assign each slot’s location or name in order to remember in where each slot was connected.

Page 22 of the Planet Technology 170S8FS user manual — 4.2.2.5 Redundant Backup Setting
Page 22 · click to enlarge
Page 22

4.2.2.5 Redundant Backup Setting

Planet Technology 170S8FS — 4.2.2.5 Redundant Backup Setting diagram (page 22)
Fig. 25 · 4.2.2.5 Redundant Backup Setting

The redundant function is to change the master line to the slave line in case of the linking fails happen.

The Redundant functions were set fixed, the master slot is slot 1(odd number slot) and the slave slot is slot 2(even number slot), and there are eight redundant groups in all. The “Act” will indicate what slot is active.

When the slave slot is active, and we need to transfer again to the master slot, we need to push on the restart button.

Page 23 of the Planet Technology 170S8FS user manual — 4.2.2.5 Redundant Backup Setting
Page 23 · click to enlarge
Page 23
Page 23 of the Planet Technology 170S8FS user manual — 4.2.2.5 Redundant Backup Setting
Page 24 of the Planet Technology 170S8FS user manual — Chapter 5 TECHNICAL SPECIFICATIONS
Page 24 · click to enlarge
Page 24

Chapter 5 TECHNICAL SPECIFICATIONS

Chassis System Capacity Sixteen bays for housing up to sixteen media converters Material Steel

One power supply provided, hot-swappable

*A second power supply for load-sharing is optional, also hot-

Cooling Two fans mounted together with the power supply or alone at

the rear Dimensions W415 mm × D 390mm × H89 mmStandard 19” size, 2 U Net Weight 7.2kg approx. (*Only one power supply included)

Fan Rated Voltage 12V DC Speed 3200 RPM +/- 250 RPM Air Delivery 42.5 CFM per min. Noise Level 36.5dB(A) Bearing System Precise ball bearing system Dimensions 80 × 80 × 25 mm

Power Supply Inputs 100 to 240 VAC, universal power supplyor -48V DC Power

Consumption 150 watts. (max.)

Temperature Operating:0°~40°C, Storage: -10°~50° C Humidity Operating:10% ~ 90%, Storage: 5% ~ 90% Overload

All outputs protected from short circuit condition, automatic

recovery Emissions FCC Class A, CE Mark Class A, VCCI Class A

Power · swappable · Protection

Page 25 of the Planet Technology 170S8FS user manual — Chapter 5 TECHNICAL SPECIFICATIONS
Page 25 · click to enlarge
Page 25

IEEE802.3 10Base-T Ethernet

IEEE802.3u 100 Base-TX Fast Ethernet

IEEE802.3x flow control Protocol CSMA/CD Data

Ethernet10Mbps (half duplex), 20Mbps (full duplex)Fast

Ethernet: 100Mbps (half duplex), 200Mbps (full duplex) LED Indicators Power On, Power Fail, Fan Fail, MGM, Console, LNK/ACT

Cable 10BaseT2-pair UTP Cat. 3,4,5; EIA/TIA568 100-ohm STP
100Base-TX2-pair UTP Cat. 5; EIA/TIA-568 100-ohm STP

Fixed Ports 1 x 10/100Base-TX port

1 x 9 pin RS-232 Console port Power

Consumption 3 watts. (Max.)

Temperature Operating: 0° ~ 50° C, Storage: -10° ~ 70° C Humidity Operating: 10% ~ 90%, Storage: 5% ~ 90% Emissions FCC Class A, CE Mark Class A, VCCI Class A

Management Module · Standards · Transfer Rate

Page 26 of the Planet Technology 170S8FS user manual — Part No.:EM-WMCv1
Page 26 · click to enlarge
Page 26

Part No.:EM-WMCv1

Ask about the Planet Technology 170S8FS

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Planet Technology 170S8FS

Be the first to ask — other owners or our team will answer.

Original document

Planet Technology 170S8FS manual PDF

26 pages·2.6 MB·Cable Box·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…