EN
Official user manual

Pico Communications 3000

26 pages·437 KB·Webcam·PDF·ENNLJA
Pico Communications 3000
Table of Contents 12 sections 2000 Series · 3000 Series · 5000 Series · PicoScope ® PC Oscilloscope Installation Guide · … ShowHide
Page 1 of the Pico Communications 3000 user manual — 2000 Series
Page 1 · click to enlarge
Page 1
Pico Communications 3000 — 2000 Series diagram (page 1)
Fig. 1 · 2000 Series

2000 Series

3000 Series

5000 Series

PicoScope ® PC Oscilloscope Installation Guide

Pico Communications 3000 — 2000 Series diagram (page 1)
Fig. 2 · 2000 Series
Page 2 of the Pico Communications 3000 user manual — PicoScope USB Oscilloscope
Page 2 · click to enlarge
Page 2
Pico Communications 3000 — PicoScope USB Oscilloscope diagram (page 2)
Fig. 3 · PicoScope USB Oscilloscope

PicoScope USB Oscilloscope

Installation guide

Installationsanweisung

Guía de instalación

Guide d’installation

Guida all’installazione

Page 3 of the Pico Communications 3000 user manual — PicoScope USB Oscilloscope
Page 3 · click to enlarge
Page 3

Issue record:

1. 18.8.05 For 2000 and 3000 series 2) 15.12.05 Fixed CD-ROM file name 3) 3.1.06 Fixed image background corruption 4) 11.5.07 New logo; updated for 5000 series; corrected international titles. Removed Win 98/ME/2000. Added Vista. 5) 25.6.07 New cover photos. Minor format changes inside. 6) 19.11.07 New address. Corrected PSU description in DE, ES, FR ,IT versions. 7) 12.3.08 Postcode correction. New email address. New WEEE symbol.

James House Colmworth Business Park

ST. NEOTS Cambridgeshire

PE19 8YP United Kingdom Tel+44 1480 396395 Fax: +44 1480 396296 Email: support@ picotech.com

Copyright © 2006-8 Pico Technology. All rights reserved.

Pico Technology · Eaton Socon

Page 6 of the Pico Communications 3000 user manual — 1 English
Page 6 · click to enlarge
Page 6

Pico Technology USB Oscilloscope Installation Guide

1 English

1.1 Introduction

Thank you for purchasing a Pico Technology USB Oscilloscope.

This guide explains how to install the software, including the product manual, from the CD-ROM supplied.

Once you have finished the installation, you will find that the product manual contains much more information about setting up and using the product and its software. The manual is installed in electronic format, but you can also print a paper copy from the PDF file on the CD-ROM.

1.2 Safety warnings

We strongly recommend that you read the general safety information below and also the product-specific safety warning in the product manual before using your product for the first time. If you do not use the equipment in the manner specified, then you may impair the protection provided. This could result in damage to your computer or injury to yourself or others.

The product manual is installed on your computer when you install the supplied software.

You can find the maximum input range and, where applicable, overload protection range in the product manual installed on your computer. Always operate the product within the specified input range. Operation outside the range of the overload protection is likely to cause permanent damage to the unit. Incorrect configuration or use on voltages outside the maximum input range can be hazardous.

Pico products are not designed for use with mains voltages. To measure mains, we recommend the use of a differential isolating probe such as the Pico Technology MI053, which is specifically designed for high-voltage measurements.

The unit contains no user-serviceable parts. Repair or calibration of the unit requires specialised test equipment and must be performed by Pico Technology or its authorised distributors.

Maximum input range · Mains voltages · Repairs

Page 7 of the Pico Communications 3000 user manual — 1 English
Page 7 · click to enlarge
Page 7

USB Oscilloscope Installation Guide Pico Technology

The ground of every product is connected directly to the ground of your computer through the USB cable supplied. This is done in order to minimise interference. Therefore, always use the supplied cable to attach the product to your computer.

As with most oscilloscopes, take care to avoid connecting the ground input of the product to anything which may be at some voltage other than ground. If in doubt, use a voltmeter to check that there is no significant AC or DC voltage between the oscilloscope ground and the point to which you intend to connect it. Failure to check may cause damage to the product or computer and could cause injury to yourself or others.

You should assume that the product does not have a protective safety earth.

1.3 Included with your PicoScope

  • Please check that your PicoScope PC Oscilloscope package contains the following items:
  • 1 PicoScope PC Oscilloscope
  • 2 Oscilloscope probes (5203/5204 oscilloscopes only)
  • 1 USB cable
  • 1 Pico Software CD
  • 1 Power adaptor (3204/3205/3206/5203/5204 oscilloscopes only) - 3204/3205/3206: UK, EU or US model selected at time of ordering - 5203/5204: universal model with UK, EU, US and AUS/NZ plugs
  • 1 Installation guide Some product packs and scope bundles may contain additional items.

1.4 System requirements

  • Please verify that your computer meets the following requirements.
  • Pentium or equivalent PC with at least 32 MB RAM, 10 MB disk space
  • Microsoft Windows XP SP2 or Vista
  • USB 1.1 compliant port minimum. USB 2.0 compliant port recommended. Free USB port on PC or powered USB hub. Will not work on a passive hub. For PicoScope 5000 Series PC Oscilloscopes, we recommend higher system specifications than these for best performance. Please see your PicoScope 5000 Series user guide, installed with your PicoScope software, for details.

Safety grounding

Page 8 of the Pico Communications 3000 user manual — 1 English
Page 8 · click to enlarge
Page 8

Pico Technology USB Oscilloscope Installation Guide

1.5 Installing the PicoScope software and manual

1) Do not connect the oscilloscope to the PC yet! 2) Insert the Pico CD into your CD-ROM drive. It should start automatically. (If it does not, follow the steps on the right.) 3) Click the “Install Application Software” button. 4) Follow the instructions on the screen to install PicoScope. 5) Restart the PC. 6) 5000 Series only: Fit the appropriate plug adaptor to the the power supply unit and plug the unit into a mains socket. Plug the lead from the power supply unit into the back of the oscilloscope. Switch on the mains power. 7) Connect the PC Oscilloscope to the PC (see connection drawing below). Ignore any warnings that appear such as “This device can perform faster” or “USB2 device connected to USB1 hub”. 8) The “New Hardware Found Wizard” will run. Follow the instructions, and if the wizard asks to connect to Windows Update, select “No”. If a warning about Windows Logo testing appears, click “Continue Anyway”. 9) With some products, the “New Hardware Found Wizard” will run twice. If this happens, repeat the previous step. 10) Click the Windows Start button, go to “Programs” and then “Pico Technology”, then select “PicoScope” to begin using the PC Oscilloscope. 11) If an oscilloscope probe is connected to the oscilloscope, you should see a small 50 Hz or 60 Hz mains signal in the oscilloscope window when you touch the probe tip with your finger.

To start the CD manually: 1) Click the Windows Start button and select “Run...” 2) Type d:\pico (where ‘d:’ is your CD-ROM drive) 3) Press the Enter key

Pico Communications 3000 — 1 English diagram (page 8)
Fig. 4 · 1 English

Key: 1) PicoScope PC Oscilloscope 2) PicoScope’s USB port 3) USB cable 4) PC 5) PC’s USB port

Page 9 of the Pico Communications 3000 user manual — 1 English
Page 9 · click to enlarge
Page 9

USB Oscilloscope Installation Guide Pico Technology

1.6 Free newsletter

Pico Technology sends out a free monthly newsletter by e-mail. This gives news of product launches, software upgrades and application notes; and hints and advice. We treat your e-mail details as confidential and will not pass them on to any third parties.

To subscribe visit:

www.picotech.com/maillist.html

1.7 Software updates / replacing lost software

The latest versions of all Pico software can be downloaded free of charge from our web site at:

www.picotech.com

If you require a new CD, please contact Pico Technology or your distributor. There may be a small charge for this service.

1.8 Writing your own software

The CD ROM contains all the manuals and drivers you will need to develop your own custom programs easily. Follow section 1.5 to install.

1.9 Input connections

The product manual installed with the software contains complete descriptions of input connections. Follow section 1.5 to install the software and the manual.

1.10 Specifications

The product manual that was installed with your Pico software contains the latest specifications for your PicoScope PC Oscilloscope. We recommend that you print a copy of the specification table and attach it inside the back cover of this guide for future reference.

1.11 Technical support

The Pico Technology technical support web site and users’ forum at:

www.picotech.com/support

contain regularly updated technical support information. Both the product manual and the web site contain phone, fax and e-mail contact information for our technical support team.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Pico Communications 3000

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Pico Communications 3000

Be the first to ask — other owners or our team will answer.

Original document

Pico Communications 3000 manual PDF

26 pages·437 KB·Webcam·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…