Fastrax
Dome Video Camera for Ceiling and Wall Mounting
EDC-141E, EDC-142E, EDC-143E, EDC-142E1, EDC-144E, EDC-142E2




to take appropriate corrective action at his/her own expense.
1.1 Features
The Fastrax II Keyboard Controller and the Fastrax II dome cameras make up the building blocks for any surveillance/security system. Using multiple Keyboard Controllers and multiple dome cameras, no place is too large for monitoring. Extensible and flexible architecture facilitates remote control functions for a variety of external switching devices such as multiplexers and DVRs.


up to 255 multiplexer
Alarm Input (up to 8)
up to 99 DVR
Alarm Output (up to 4)
up to 32 cameras
up to 3 Slave keyboards
Figure 1 - Typical System Configuration

Remove window Assemble bubble ring ass’y
Figure 2 - Assemble bubble ring ass’y

2.1 Package Contents
The package contains the following:
1x Fastrax II E (Dome Camera)
1x Instruction Manual (This Document)
3x Assembly Screws for Attaching Fastrax II E
Different version will not support alarm input and output.
The dome camera is for use in surface mounting applications and the mounting surface should be capable of supporting loads up to 10lb (4.5kg).
The dome camera’s base should be attached to a structural object, such as a hard wood, wall stud or ceiling rafter that supports the weight of the dome camera.

Align extruded tap in the base to the keyhole on the PCB in the body
Figure 3 - Installation


1 ~ 2 Alarm input
3 ~ 4 Alarm input
J-Box (Back) J-Box (Front)
Up to 128 Dome cameras including 32 alarm mode can be connected at DOME2 port.
DATA2 port should be connected in case that DOME2 port or DVR port are used.
Figure 4- Basic installation diagram
The dome camera must be installed by qualified service personnel in accordance with all local and federal electrical and building codes. The system should be installed according to Figures 4 through 9.

Power 24VAC Power 24VAC

BNC
BNC BNC
RS-485 (–) Pin No. 4 RS-485 (+) Pin No. 6
J-Box (Back) J-Box (Front)
Figure 5 - Single Multiplexer

Power 24VAC Power 24VAC

BNC
BNC
BNC
BNC
RS-485 (–) Pin No. 4 RS-485 (+) Pin No. 6
J-Box (Back) J-Box (Front)
Spot output of the first multiplexer to be connected to 16th input of the second multiplexer.
And first spot output of the 2nd multiplexer to be connected to the spot monitor. You will see tthe picture of the selected camera (1-31) on spot monitor by selecting camera No. + Cam.
Figure 6 - Two Multiplexer

Power 24VAC Power 24VAC

BNC
2nd Main Monitor Spot Monitor
Spot Monitor for Master K/B
BNC
BNC
RS-485 (–) Pin No. 4 RS-485 (+) Pin No. 6
J-Box (Back) J-Box (Front)
Spot output 1 of the first multiplexer to be connected to 16th input of the second multiplexer.
n: User, Spot out of nth to be connected to (17-n)th camera input of the 2nd multiplexer. nth spot out of the 2nd multiplexer to be connected to the nth spot monitor. Each user will see the picture of the selected camera (1 ~ (31-n)) on nth spot monitor of the Mux 2 by selecting camera No. + Cam.
Figure 7 - Two Multiplexer with Slave Keyboard Controller

Power 24VAC Power 24VAC

BNC
2nd Main Monitor Spot Monitor
Spot Monitor for Master K/B
BNC
BNC
RS-485 (–) Pin No. 4 RS-485 (+) Pin No. 6
J-Box (Back) J-Box (Front)
Spot output 1 of the first multiplexer to be connected to 16th input of the second multiplexer.
n: User, Spot out of nth to be connected to (17-n)th camera input of the 2nd multiplexer. nth spot out of the 2nd multiplexer to be connected to the nth spot monitor. Each user will see the picture of the selected camera (1 ~ (31-n)) on nth spot monitor of the Mux 2 by selecting camera No. + Cam.
Figure 8 - Two Multiplexer with Slave Keyboard Controller (method 2)


Addresses (ID) and protocol
Figure 9 - Layout of Switches
The device which is connected at end of line, whether it is a dome camera or keyboard controller, must have the cable for communication terminated by setting the appropriate DIP switch. Without proper termination, there is potential for control signal errors. Total length of the cable for communication should not exceed 1.2km.
Figure 10 - Setting Unit for Termination
Termination switches · selection switches


Figure 11 - Termination Diagram
To prevent damage, each dome camera must have a unique address (ID). When installing multiple dome cameras using a multiplexer, it is suggested that the dome camera address matches the multiplexer port number.
If you wan to set the address more than 999, you should connect the service provider.
Example: Port 1 = Dome 1, Port 2 = Dome 2 ... Port 16 = Dome 16. If more than 16 dome cameras are installed using two or more multiplexers, ID of the dome camera should be ID of MUX x No. of camera IN. (e.g. multiplexer ID= n, Camera IN= m then ID of Dome =16x(n-1)+m )
Refer to Figures 4-5 for setting the dome camera address (ID) and protocol selection.

Beyond ID 999, contact your service provider.
Figure 12 - Setting Address (ID) of Dome Camera

If a dome camera is to be installed with a Fastrax keyboard controller, select F2 protocol.
Consult service personnel if a dome camera is installed with device other than a keyboard controller.

D1 S4-1 Enable Disable Alarm D2 S4-2 PAL NTSC NTSC/PAL D3 S4-3 Endless D4 S4-4 RS-422 RS-485 RS-422/RS-485


Off Off Off Fastrax, Pelco D&P, Dynacolor, Ernitec &
Philips G3 Protocol (Default) Off Off On Reserved Off On Off Sensormatic RS-422 Off On On Reserved On Off Off Vicon Protocol On Off On Reserved On On Off Dynacolor On On On Reserved

Off Off Off 2400 bps Off Off On 4800 bps Off On Off 9600 bps (Default) Off On On 19200 bps On Off Off 38400 bps On Off On 57600 bps On On Off 115200 bps
Figure 13 – Protocol Selection Switches
Unless Baud rate match, universal protocol will not work.

Off Off Default cameras (Default) Off On Reserved On Off Reserved On On Reserved

The dome camera can be controlled remotely by an external device or control system, such as a control keyboard, using RS-485 half-duplex, RS-422 duplex or simplex serial communications signals. Connect Marked Rx+, Rx- to Tx+ and Tx- of the RS-485 control system.
If control system is RS-422, connect Rx+ (Tx+), Rx+ (Tx-) and Rx+, Rx- of the dome camera to Tx+, Tx- and Rx+, Rx- of the control device respectively.
Connect the video out (BNC) connector to the monitor or video input.
AL1 to 8 (Alarm In)
You can use external devices to signal the dome camera to react on events. Mechanical or electrical switches can be wired to the AL (Alarm In) and GND (Ground) connectors. See Chapter 3 - Program and Operation for configuring alarm input.
Connect the ground side of the Alarm input and/or alarm output to the GND connector.
NC(NO)1 TO 4 (Normal Close or Normal Open: Alarm Out)
The dome camera can activate external devices such as buzzers or lights. Connect the device to the NC(NO) (Alarm Out) and COM (Common) connectors. See Chapter 3 - Program and Operation for configuring alarm output.
Connect the power of 24VAC 850mA to the dome camera.
Use certified / Listed Class 2 power supply transformer only.
Once installed apply power to the dome camera. The dome camera will start a initializing sequence. When configuration is done, the following information is displayed on the keyboard controller’s LCD.
CHECK NO. : OK!
CHECK AAAA : OK!
CHECK 5555 : OK!
FASTRAX II E Vx.xxx
WAIT DOME SETTING.
INIT PAN ORGIN SET OK
INIT CAMERA SET OK
PRESET No.
CAMERA TITLE
TITLE
CAMERA ID
EMPTY DATA !
INFORMATION DISPLAY
COMMAND ON WORKING
T001 DOMEID:0001
ALARM:1 W_360.0,090.0
PAN & TILT DEGREE
ALARM DISPLAY
VIEW DIRECTION
GND (Ground) · CAMERA TYPE xxxx · OSD Position

3.1 Selecting Dome Camera
Before you program or operate a dome camera, you must select the dome camera by pressing the dome camera No. + CAM successively.
Example: Pressing 1, 0 and CAM key sequentially will select dome camera 10. The selected dome camera ID will be displayed on the LCD monitor of the keyboard controller.
You can call up the On-screen menu utility on your monitor by pressing MENU key on the keyboard controller, the following On-screen menu utility will appear:
AUTO SCAN PRESET TOUR PATTERN ALARM AREA TITLE PRIVACY ZONE CAMERA DOME SETUP EXIT(ESC TO EXIT)
MENU Call on On-screen menu utility
Go into the sub-menu items. Execute the command (exit) Change value. Navigate through the menu items.
Joystick left or right
Joystick up or down Navigate through the menu items.
Joystick down Finish editing title. Same effect as Enter key
Zoom handle twist Change value. Enter editing title mode at Preset menu.
CTRL + Joystick PTZ control of the selected camera
Action Function · ESC Escape (EXIT)

3.4 Auto Scan (First Item of the Main menu / Shortcut: Scan)
The Auto scan supports up to 8 programmed angles at user-programmable speeds. Follow these steps to program Auto Scan:
SCAN 01 : AUTOSCAN01 SPEED(MODE) : FAST VECTOR START ANGLE : 127.1, 027.7 X7 END ANGLE : 157.7, 080.7 X13 SCAN DIR. : CCW SWAP : OFF SAVE AND EXIT (ESC TO CANCEL)
HOLD DOWN CTRL KEY WHILE SELECT POSITION.
NORMAL1 (SLOWER) <––> NORMAL9 ( FASTER)
SLOW VECTOR, FAST VECTOR: Move from start point to end point including tilt and zoom simultaneously and linearly. In case of EDC-143E, EDC-142E1 and EDC-142E2, zoom is fixed at more wide angle and the zoom magnification information is not displayed.
position at a specific speed. (Pan only)
a. Before entering the Auto Scan menu, select a preset position as a starting point for Auto Scan.
Example: 2 + Prst and do step 1 to 4. Instead of step 5, just press the Ctrl/PGM key at the start angle position, the current position will be displayed as a start position.
b. Save and exit from the menu.
c. In normal mode, call a preset to be the end point of scan. Press 3 + Prst then press Scan key to enter the Auto Scan menu. Move the cursor position to END ANGLE. Just press Ctrl/PGM key at the end angle position. Do step 7.
Example: Preset 001>002>003>004>005>006, Auto Scan 01 starts at 002, ends at 003, Auto Scan 02 starts at 005, ends at 006. Tour 001, 002, A01, 004, A02.
1 2 2~3 4 5~6 1 2 2~3
Where : Quick move, ~ : Programmed speed by Auto Scan.

If you need to view specific locations routinely, you should program presets. A preset is a programmed video scene with automatic pan, tilt, zoom, focus and iris settings. Once programmed, entering the number and pressing a Preset button on your controller automatically calls up the preset. In addition, presets may be assigned to alarm actions or as the „home” position for the dome camera. As many as 240 presets, whose positions are saved in the dome’s non- volatile memory, may be programmed.
There are three pages of preset menu, each page can hold 80 presets. Pages can be scrolled by pushing the Joystick to the left or right on the first or last No. of Preset.
1234567890 1234567890 00 * * * ===== 01========== 02========== 03========== 04========== 05========== 06========== 07========== JOY-LEFT TO PREV. PAGE SAVE AND EXIT(ESC TO CANCEL)
: Current cursor position
Follow steps below to store the Preset positions:

Select a view to be stored (direction of the camera, zoom and focus), then press No. (1 to 240), and then press Pgm, Prst subsequently. The current view will be stored to the selected preset number if position is empty. If selected preset number is not empty, „PRESET EXISTING” message will be displayed on the monitor and ask to overwrite.
Example: 1, 0, 1 + Pgm + Prst will store current view as preset No. 101. In this case, focus and Iris mode will be programmed as Auto, dwell time will be set
to 3 sec.
There are 8 programmable Tours. Each Tour consists of up to 42 Preset positions, Patterns, Scans or other Tours (second-level). Using second-level Tours, it can be expanded to over 300 functions in a single Tour. However Tours in second level Tour will be ignored when called by a Tours. The following example illustrates this concept:
If Tour1 has Preset1 Preset2 Tour2 Tour3 and
Tour2 has Preset3 Preset4 Preset5 Tour4 and
Tour3 has Preset6 Pattern1 and
Tour4 has Preset7.
Tour1 executes as follows:
Preset1 Preset2 Preset3 Preset4 Preset5 Preset6 Pattern1
Preset1 ... (Repeat)
Tour2 executes as follows:
Preset3 Preset4 Preset5 Preset7 Preset3 ... Repeat
(Tour4 is still valid if called directly from Tour2.)
=== === 003 === A08 === T02 === 001 === T08 === SAVE AND EXIT (ESC TO CANCEL) PRESS FUNCTION KEY AND ROTATE JOYSTICK TO SELECT NUMBER.
Follow the steps below to program the Tours:

you can make the camera travel from a preset position to another preset position at a specific speed.
Example: Preset 001>002>003>004>005>006, Auto Scan 01 starts at preset 002, ends at preset 003, Auto Scan 02 starts at preset 005, ends at preset
006; Tour 001, 002, A01, 004, A02.
1 2 2~3 4 5~6, repeat
3.8 Pattern (Fourth 4 Item of the Main menu / Shortcut: Ptrn)
The Pattern feature records user control of the selected dome camera for up to 240 seconds. Up to four 4 patterns can be stored and played back by pressing No.+ Ptrn keys subsequently.
HOLD DOWN CTRL KEY WHILE RECORDING.
Follow steps below to program the Pattern:

3.9 Alarm (This menu shows on only specific model, Fifth Item of Main menu)
NO PRI PRS IN OUT HLD LATCH 01 1 001 OFF OFF 03 OFF 02 8 001 OFF OUT1 03 OFF 03 1 240 NO OUT1 03 OFF 04 2 001 NC OUT4 03 OFF 05 1 001 OFF OFF 03 OFF 06 8 001 OFF OUT1 03 OFF 07 1 240 NO OUT1 03 OFF 08 2 001 NC OUT4 03 OFF SAVE AND EXIT (ESC TO CANCEL)
PRI : Lower No. has higher priority, Equal priority alarms will be serviced repeatedly.
PRS : Stored preset number to be called by alarm.
OUT : OUT1~OUT4 - Relay out 1,2,3,4, OFF - No output.
LATCH : ON - Shows all alarms including past alarm, OFF - Shows activated alarms only.
There is one „0” PRIO which is the highest priority. „0” priority can choose Autoscan, Pattern or Tour. When responding „0” priority alarm, there is no respond other alarm until finishing „0” priority action
Enter a specific name on programmed angle between START and END. For the screen below, when the camera points at an angle between 124.3° to 359.5°, ABC will be displayed on the screen.
NO TITLE START END 01 ACB 124.3 359.5 02 xxxxxxxxxxxxxxxx ===== ===== 03 xxxxxxxxxxxxxxxx ===== ===== 04 xxxxxxxxxxxxxxxx ===== ===== 05 xxxxxxxxxxxxxxxx ===== ===== 06 xxxxxxxxxxxxxxxx ===== ===== 07 xxxxxxxxxxxxxxxx ===== ===== 08 xxxxxxxxxxxxxxxx ===== ===== SAVE AND EXIT (ESC TO CANCEL) HOLD DOWN CTRL KEY TO MOVE
PANNING AND SET AREA ANGLE.

Pages can be scrolled through by pushing the Joystick to the left or right on the first or last column of the menu. Pushing the Joystick to left on the „NO” column (01 ~ 08) of the menu to scroll to the previous page. Push the Joystick to right on the „END” column to go to the next page.
Hide up to 8 unwanted views in a camera.
NO TITLE METHOD 01 xxxxxxxxxxxxxxxx ON BLOCK 02 xxxxxxxxxxxxxxxx OFF V.OFF 03 xxxxxxxxxxxxxxxx NONE ==== 04 xxxxxxxxxxxxxxxx NONE ==== 05 xxxxxxxxxxxxxxxx NONE ==== 06 xxxxxxxxxxxxxxxx NONE ==== 07 xxxxxxxxxxxxxxxx NONE ==== 08 xxxxxxxxxxxxxxxx NONE ====

FOCUS CONTROL WB CONTROL AE CONTROL LINE LOCK CONTROL SHARPNESS : 9 BACK LIGHT : OFF DIGITAL ZOOM : OFF (2x/4x/ MAX) NIGHT SHOT CONTROL (optional) SAVE AND EXIT (ESC TO CANCEL)
SHARPNESS The higher the value, the more edges in the picture will be enhanced.
BACK LIGHT Objects in front of bright backgrounds will be clearer with BLC ON.
DIGITAL ZOOM OFF: Zoom range is limited to the optical.
2x : Zoom is extendable up to 2x of digital range.
4x : Zoom is extendable up to 4x of digital range.
NIGHT SHOT CONTROL (Not at EDC-142E1)
EDC-143E EDC-142E1 EDC-142E2
FOCUS SETUP
FOCUS SETUP
MODE : AUTO
MODE : AUTO/MANUAL
AF SENSITIVITY : HIGH
EXIT(ESC TO EXIT)
EXIT(ESC TO EXIT)
MODE: AUTO / MANUAL Use manual mode in normal use.
AF SENSITVITY: HIGH / LOW (only EDC-141E, EDP No. 74086; EDC-142E, EDP No. 74081; EDC-144E, EDP No. 74100)
HIGH: Use this option when shooting fast motion.
LOW: Offers better focus stability. In low luminance conditions, Auto Focus stops operation even when brightness changes, enabling stable
images of moving objects.

WB SETUP
MODE : MANUAL / AUTO / INDOOR / OUTDOOR / ONE PUSH / ATW RGAIN : 0 ~ 255 BGAIN : 0 ~ 255
Use the ATW mode for normal use.
RGAIN / BGAIN modes are controllable only in MANUAL Mode.
Push the Joystick to the right or left to change.
then holds that position until the next rotating the Joystick handle.
WB SETUP
Use the AUTO mode for normal use.
RGAIN / BGAIN modes are controllable only in MANUAL Mode.
Push the Joystick to the right or left to change.
WB SETUP
MODE : AWB / WAWB / INDOOR / OUTDOOR / MANUAL WAWB: Wide range auto white balance mode RGAIN : 0 ~ 255 BGAIN : 0 ~ 255
Use the AWB mode for normal use.
RGAIN / BGAIN modes are controllable only in MANUAL Mode.
Push the Joystick to the right or left to change.

AE SETUP
MODE : FULL AUTO SLOW SHUTTER : MANUAL IRIS : F2.4 GAIN : 0 DB BRIGHT : 14 SHUTTER : 1/60 EXIT (ESC TO EXIT)
MODE FULL AUTO / MANUAL / IRIS PRIO / SHUTTER PRIO / BRIGHT
SLOW SHUTTER AUTO / MANUAL – AUTO effects only FULL AUTO mode
IRIS : CLOSE / F22 / F19 / F16 / F14 / F11 / F9.6 / F8.0 / F6.8 / F5.6 / F4.8 / F4.0 / F3.4 / F2.8 / F2.4 / F2.0 / F1.6 / F1.4
AE SETUP
MODE : AE (DSS) SLOW SHUTTER : 1/4 IRIS : F2.4 GAIN : 0 DB WDR MODE : ON SHUTTER : AUTO EXIT (ESC TO EXIT)
MODE : SHUTTER PRIO / IRIS PRIO / AGC PRIO ) / AE (DARK) (IR Cut filter is automatically turned on and off more dark condition than AE (DARK) / AE (DSS) (automatic exposure without switching IR Cut filter)
IRIS : F1.6 / F2.2 / F3.2 / F4.4 / F6.4 / F8.8 / F12 / F17 / F24 / F34
WDR MODE : Wide Dynamic Range Technology uses two shutter speeds in alternative video fields - high and normal - every 60th (or 50th) of a second and combines two fields into one progressive scan frame. It allows every detail to be captured accurately even if one portion of an image is brillantly bright while other portions are dark.
SHUTTER : 1/2, 1/4, 1/8, 1/15, 1/30, 1/60, 1/120, 1/180, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000, 1/30000 (1/1.5, 1/3, 1/6, 1/12, 1/25, 1/50, 1/100, 1/150, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000, 1/30000)

AE SETUP
MODE : FULL AUTO SLOW SHUTTER : AUTO IRIS : F1.6 GAIN : 2DB BRIGHT : 30 SHUTTER : AUTO WDR MODE : ON EXIT (ESC TO EXIT)
IRIS : CLOSE / F1,6 / F2,0 / F2,8 / F4,0 / F5,6 / F8,0 / F11 / F16 / F22 / F32
BRIGHT : User can adjust brightness level (0 – +90). Level 30 is default.
SHUTTER : 1/1, 1/2, 1/3, 1/6, 1/10, 1/30, 1/60, 1/100, 1/125, 1/250, 1/500, 1/1.000, 1/2.000, 1/5.000, 1/10.000 (1/1, 1/2, 1/3, 1/6, 1/12, 1/25, 1/50, 1/100, 1/120, 1/250, 1/500, 1/1.000, 1/2.000, 1/4.000, 1/10.000)
WDR MODE : Wide Dynamic Range Technology uses two shutter speeds in alternative video fields - high and normal - every 60th (or 50th) of a second and combines two fields into one progressive scan frame. It allows every detail to be captured accurately even if one portion of an image is brillantly bright while other portions are dark.
MODE : INTERNAL / EXTERNAL. Adjusts phase of picture with other cameras in EXTERNAL mode.
EXIT (ESC TO EXIT)
The NIGHT SHOT option removes the IR cutoff filter of the camera and makes the camera sensitive to near infrared. This will set the BLACK & WHITE option to ON automatically.
AUTO: Camera goes in to B&W mode at low light.
The operator can enable NIGHT SHOT for all dome cameras at the same time. If the NIGHT SHOT mode is set to GLOBAL, „9 9 9„ + Enter/Glbl will turn Off the NIGHT SHOT mode „8 8 8” + Enter/Glbl will turn On the NIGHT SHOT mode.
LOCAL CONTROL: ON/OFF will enable and disable Night Shot mode of an individual camera.

CONFIGURATION MENU
LANGUAGE SETUP HOME FUNCTION SETUP OSD DISPLAY VIEW ANGLE SETUP INITIALIZE DATA ORIGIN OFFSET DOME RESET SYSTEM INFORMATION EXIT (ESC TO EXIT)
LANGUAGE : Select the language you want. * This setup displays more than 3.0 of the ROM version.
After a dome control menu item has been selected, follow the directions below to set the function.
HOME FUNCTION : NONE FUNCTION NUMBER : --- WATING TIME : 120SEC FUNCTION ENABLE : OFF SAVE AND EXIT (ESC TO CANCEL)
The Home function can be set so that the camera automatically goes to Preset, Tour, Pattern, Auto Scan after the keyboard controller has been idle for a amount of time. For example, if the Joystick controller is idle for 10 seconds, the camera goes to preset 1.
Follow these steps to program the Home position:

CAMERA TITLE : 8 CHARACTER CAN BE SET
VIEW DIRECTION : ON / OFF
DOME OSD DISPLAY : ON / OFF
AREA DISPLAY : ON / OFF
„ON” sets current direction as N(North) and the coordinate angle to 000. „OFF” hides the directional title. Every 90 degrees of clockwise rotation will change the title to E(East), S(South), W(West). If using the ON/OFF option frequently, it is recommended that you set „North” as a Preset. Recall the „North” Preset before enabling the directional title.
All display or title will disappear when DOME OSD DISPLAY sets OFF
If this option is enabled, the nearest area title will be displayed when the camera is moving whether by manual operation, Auto Scan, or Pattern. Select ON or OFF by pushing the Joystick to the right or to the left. The Dome camera’s OSD option will override this function (Dome camera’s OSD must be enabled).
FLIP: ON / OFF

When the dome camera is installed near wall, panning range could be programmed by user.
RIGHT LIMIT : 000.0 LEFT LIMIT : 000.0 ENABLE SWAP : RIGHT/LEFT SAVE AND EXIT (ESC TO CANCEL)
Allows the dome camera to automatically turn 180 degrees when the camera tilts to its lower position.
When camera reaches floor alone moving object, it will stop. Release the Joystick handle instantly and then pull down to run flip fucntion. The speed of following object will be same speed as previous.
This option is used to set the limit of the horizontal view angle so that the trim ring or ceiling does not obstruct the horizontal image when zooming out (wide angle).
ON: In some installations it is desirable for the dome camera to be able to see the above horizon. When this option is chosen, the dome will tilt up over the horizon (about -10 degrees). When the lens is zoomed out, you can see the ceiling line. But when the lens is zoomed in the viewing angle is narrower, and the ceiling line disappears.
Without Bubble: The tilt range of the camera is limited to see the horizon so the picture shows part of the ceiling line.
With Bubble: The tilt range of the camera is limited to see below the horizon (10 degrees). Over Angle is not sufficient enough to avoid ceiling obstructions, please adjust Origin Offset of tilt angle as described below.
FACTORY DEFAULT ERASE PROGRAMMED DATA EXIT (ESC TO EXIT)
Erase all stored data from the Flash-ROM of the selected dome camera. You will be asked to enter Yes or No. If you intend to erase all data then press the Menu key, otherwise press the ESC key to exit without erasing. The erased data includes all stored data (titles, presets, and tours ) except origin offset.
The offset value is still valid after all data is erased. The offset value can be zero only with default set of Offset origin menu.
function in Keyboard Configuration utility.) Data from the selected dome camera can be stored in the keyboard controller temporarily. If you want to save the data of all installed dome cameras, you need a special I/O interface and software for PC.
This feature is useful to align a replaced dome camera to the exactly same position as the previously installed dome camera.
Dome camera’s origin set and all data initialize option do not override offset values. Only the default set option in this menu will set the offset value to zero. This can be used to avoid ceiling obstructions.

This feature is used to re-calibrate the orientation of a selected dome camera. Origin offset value is not affected by this function. (Offset is still valid after origin set)
CAMERA TYPE : XXXXXXX H/W VERSION : V2.1 ROM VERSION : V2.11 PROTOCOL : F2E BAUDRATE : 9600BPS EXIT (ESC TO EXIT)
A Dome camera’s Setup menu provides essential information about the dome camera when service is required. When you view this screen, you can determine the camera type, ROM version. The information on this screen cannot be modified.
If problems occur, verify the installation of the camera with the instructions in this manual and with other operating equipment. Isolate the problem to the specific piece of equipment in the system and refer to the equipment manual for further information.
Verify that power is connected to all pieces of equipment in the system. Verify that the power switches are in the ON position. Check the video connections (see Figures 4).
Check that the BNC connectors are inserted properly. Check the voltage level of the dome camera. Check that 8 pin cable is connected to the Keyboard. Check 8 pin cable for Keyboard is proprietary. (Cable for video is shielded.) Check termination of Video.
Reset the cameras using the Dome configuration menus. Check that the dome cameras are inserted properly in the base. Check the voltage level of the dome camera. Camera number does not match the multiplexer number. Check the camera ID and insert the BNC cable into the proper input of the multiplexer. Picture is torn when switching Check Line Lock setting and adjust phase of L/L (see page 25).
Dome cameras lose their positions.
Problem Possible Solution · No video · Poor video quality

Alarm Actions The assigned responses for the dome camera when inputs change from normal to abnormal states. The dome may run a Preset, Pattern, or have no assigned action for each of the four dome inputs. The dome may also send alarm states to the host controller for processing. See also Input and Normal Input State. Areas Programmed start and end points of the dome’s field of view around its pan axis. Each area is a part of a circular viewing area that extends around the dome. The areas can be different sizes. Up to 16 areas can be programmed for the dome. Automatic Gain Control (AGC)
Allows for the amplification of the video signal in scenes with minimal ambient light. Many low-light scenes result in picture noise. As gain is increased, the picture noise is also amplified. When AGC is enabled, the value of the gain setting is based on feedback from the camera. When AGC is disabled, the camera uses the value set for the manual gain setting. The trade-off between picture level and noise may be adjusted when AGC is disabled. On-screen Menu The text overlay menu system used for setting dome features. The utility is accessed using a keystroke combination. The utility provides settings for camera functions, zoom, alarms, text display, and password protection. Flip Allows the dome to automatically turn 180 degrees when the camera tilts to its lower limit and stays in that position for a brief delay. When the dome flips (rotates), the camera starts moving upward as long as the tilt control is kept in the down position. Once the Joystick handle is released to neutral position, the tilt control returns to its normal operational mode. The flip feature is useful when you need to track someone who walks directly beneath of the dome and continues on the other side. Home Position The default position to which the dome camera returns after an assigned period of inactivity passes. The default position may be a Preset, Tour, Pattern, or No Action. Input Alarm A connection point on the dome camera that enables the system to monitor Input Devices. There are four inputs available for the dome camera. Input Devices External devices that provide information about the condition of system components that connect to the inputs on the dome camera. Typical input devices include door contacts, motion detectors and smoke detectors. IR Mode A feature of the camera that permits manual or automatic switching between colour and IR (black-and-white) operation. When IR mode is active, clearer images may be obtained under low-light conditions. Line Lock Allows you to phase lock the video with the AC power line. When line lock is enabled, it prevents vertical video rolling when switching multiple cameras to a single monitor. If text appears slightly tinted on colour monitors, disabling the line lock may prevent this problem. Name Information Relates to the display the dome name, the area where the dome is pointing, the name of the preset or pattern that is running, and alarm names. The display of each type of name setting can be enabled or disabled. When the display of camera or area title (name) is enabled, the information appears on the screen continuously. Preset, tour and pattern titles (names) appear only while they are active. Normal Input State Describes the expected state of a device connected to one of eight dome camera’s inputs. The normal state may be open or closed. When a device is not in its normal input state, an alarm is issued. North Position User-definable setting that may correspond to magnetic north or some well-known landmark. Used to approximate the camera dome's pointing direction when Direction Indicators are enabled. Low Shutter Setting used to improve the quality of video obtained in extreme low-light situations. When the Low Shutter setting is enabled, low- light information is collected over multiple fields based on the Shutter Limit setting. As a result, video may appear blurred or choppy in extreme low-light situations. This setting does not effect camera operation in normal lighting situations. See also Automatic Gain Control (AGC). Pattern A series of pan, tilt, zoom and focus movements from a single programmable dome. Up to 8 patterns may be programmed for the dome camera. Preset Programmed video scene, based on a specific pan, tilt, zoom, and focus settings. Up to 240 presets may be programmed for the dome camera. Privacy Zones This function maskes areas of the dome camera's viewing area. These masks prevent operators of the surveillance system from viewing these designated zones. The Privacy Zones move in relation to the dome camera’s pan/tilt position. In addition, the apparent size of the Privacy Zone adjusts automatically as the lens zooms in or out. Up to eight Privacy Zones may be established for a dome camera. Shutter Limit Setting used to define the maximum exposure time for the Open Shutter setting. The values for the setting range from 1/2 to 1/60. The default setting is 1/4. Vector Scan Move from start point to end point including tilt and zoom simultaneously and linearly. WDR Wide Dynamic Range Technology uses two shutter speeds in alternative video fields-high and normal- every 60th (or 50th) of a second and combines two fields into one progressive scan frame. It allows every detail to be captured accurately even if one portion of an image is brillantly. Whether at the high shutter speed or normal shutter speed, the progressive scan CCD provides a horizontal resolution of 470 lines. As a result, combined fields yield a frame of high-quality images. White balance Adjustments in the colour hue (red and blue) gains for a camera so that true white appears white in the image. It is normally com pensated for by the automatic gain control. In some lighting conditions, you may need to manually adjust the red and blue settings for optimal viewing. When Automatic White Balance is enabled, the camera measures the image and automatically adjusts the red and blue settings to balance white. When Automatic White Balance is disabled, the camera uses the values set for the red and blue settings to balance white.

Short Cut Key Function PRST Pop up preset setup menu TOUR Pop up guard Tour setup menu PTRN Pop up Pattern setup menu SCAN Pop up Auto Scan setup menu NO.+ PGM + PRST Store the current view at the selected number NO.+ PGM + TOUR Pop up tour setup menu at the selected number NO.+ PGM + SCAN Pop up auto scan setup menu at the selected number 1 ~ 4 + ON Turn On Relay 1 ~ 4 + OFF Turn Off Relay 10 + ON Night Shot on 10 + OFF Night Shot off 11 + ON BLC on 11 + OFF BLC off 12 + ON Digital Zoom on (According to digital zoom setting) 12 + OFF Digital Zoom off 13 + ON Dome OSD on 13 + OFF Dome OSD off 14 + ON Dome Area Title Display on 14 + OFF Dome Area Title Display off 15 + ON View Direction on 15 + OFF View Direction off 100 + ON Shutter speed auto 101 + ON Shutter speed 1/4 (PAL 1/3) sec 102 + ON Shutter speed 1/2 sec 103 + ON Shutter speed 1 sec 104 + ON WDR on 104 + OFF WDR off
Some function may not operate according to the model.

Model EDC-142E EDC-141E EDC-143E EDC-142E1 EDC-144E EDC-142E2 EDP 74081 74086 74091 74093 74100 74117 Imager 1/4” 752 (H) x 582 (V) pixels (Sony ExView Interline Transfer CCD) Sensitivity 1.0Lux at F1.4 (0.75Lux at F1.2)
0.7Lux at F1.4 (0.5Lux at F1.2);
3.0Lux at F1.6 (1.7Lux at F1.2); 0.2Lux at
1.0Lux at F1.4; 0.02Lux at 1sec. shutter speed
0.35Lux at F1.6 (0.2Lux at F1.2); 0.2Lux at
1.0Lux at F1.4; 0.02Lux at 1sec. shutter speed
0.05Lux at 1/3sec. shutter speed; 0.01Lux
1/3sec. shutter speed; 0.02Lux
1/3sec. shutter speed (F1.6);
at 1/3sec. shutter speed and IR cut filter
at 1/3sec. shutter speed and IR cut filter
0.02Lux at 1/3sec. shutter speed (colour)
0.01Lux at 1/3sec. shutter speed (b&w)
Horizontal resolution 480 TV lines Adresses – Up to 999 Dome ID’s Dynamic range (WDR) – 60db – Speed range at manual control (pan) 0.1° to 90°/sec., Turbo: 360°/sec.
Speed range at manual control (tilt) 0.1° to 90°/sec. (Proportional
0.5° to 90°/sec. (Proportional to the zoom position)
Preset speed Up to 380°/sec. pan Rotation range 360° (endless) Vertical tilt range -10° to +90° -4° ~ +90° Preset positioning 240 presets with 16-character labels each. 0.75sec. max. preset recall time Backlash 0.2° Patterns 4 patterns: 1x up to 240sec., or 3x up to 240sec. in total Tours Up to 8 User programmable guard tours with vector scan. Consisting of 42 presets and other functions with
individual dwell time (3 to 99sec.). Selectable fast or slow vector scan Autoscan 8 User programmable auto scans with selectable fast or slow vector scan, 9 selectable speeds Proportional pan and tilt – Continually decreases pan and tilt speeds in proportion to depth of zoom Auto flip function Rotates dome 180° at bottom of tilt travel Programmable park position Included Window blanking – 8 dynamic window blanking zones with user-defined four-sided shapes
8 areas 8 dynamic window blanking
and up to 16-character labels each
four-sided shapes and up to 16-character
Zones – 16 each with programmable text labels
16 each with programmable
in size) can be labelled with up to 16 characters
in size) can be labelled with up to 16 characters
each or set to
each or set to
video In/outdoor use Indoor/outdoor camera preferences IR cut filter – Motorized, switchable filter. Automatic function depend on the
– Motorized, switchable filter. Automatic function depend on the
amount of light. In removed filter position, the colour signal will be
amount of light. In removed filter position, the colour signal will be
switched OFF. Digital signal processing (DSP) Yes (DSP-3R) Signal-to-noise ratio 50dB Automatic gain control (AGC) Automatic (ON/OFF switchable) Shutter speed (AES/MES) Automatic/ manual: 1/50 to
switched OFF.
1/10,000 sec.
1/10,000 sec.
1/30,000sec.
1/10,000sec.
1/10,000sec.
1/10,000sec.

Model EDC-142E EDC-141E EDC-143E EDC-142E1 EDC-144E EDC-142E2 EDP 74081 74086 74091 74093 74100 74117 Shutter modes – High and Low Speed shutter – High and Low Speed shutter
Synchronization Internal/AC line lock, phase adjustment via remote control White balance Modes: Manual, Automatic, Indoor, Outdoor, ATW Video output 1Vp-p, CVBS, 75ohms, BNC Zoom range F1.4-3.0/4.1-73.8mm (18x optical,
F1.4/3.8- 83.6mm (22x optical, 12x digital zoom) Horizontal angle of view 48° (Wide); 2.7° (Tele end) 54° (Wide); 2.5° (Tele end)
12x digital zoom) F1.6/ 3.6~82.8mm (23 optical, 10x
F1.4/3.8- 83.6mm (22x optical, 12x digital zoom)
F1.6~F80/3.5 ~ 91mm (26x
optical, 12x digital zoom)
54.2° (Wide); 2.2° (Tele end) 52° (Wide); 2.4° (Tele end) Iris control Automatic (with manual override) Focus control Automatic with manual override Minimum object distance (MOD) 0.3m Menu driven set-up ON/OFF switchable Text display 16-character labels Menu languages English English, German, French, Spanish, Portuguese, Italian, Polish Alarm processing – Programmable alarm action with selectable priority levels Alarm inputs – 8, selectable between NO and NC Bubble 4.9” (125mm), clear acrylic plastic Control interfaces RS-422/RS-485,
52° (Wide); 2.4° (Tele end)
RS-422/RS-485, 9600Baud, 999 camera ID adresses selectable. Besides the keyboard control
9600Baud, 999 camera ID adres
via the eneo EDC-KBD(M) series, the control via matrix switchers and keyboards from Pelco
(D+P protocol), Ernitec, Philips G3, Sensormatic RS-422, (back channel via RS-422 is not
ses selectable. Besides the key board control via
activated), Vicon and Dynacolor is available.
the eneo EDC- KBD(M) series,
the control via matrix switchers
and keyboards from Pelco (D+P protocol), Ernitec,
etc. is available.
Keyboard control Direct mode control with Eneo EDC-KBD(M) keyboard series, or in conjunction with the eneo Triplex Multiplexer
series VBMT/VCMT-8000 and DVR series DLR(2) and DXR Auxiliary outputs – 4 relays with NO/NC contact, 24VDC/1A resistive Remote control Camera remote settings via keyboard Operation protection Available Backup Non-volatile back box memory stores all camera and site-specific dome settings Supply voltage 18 to 30VAC (24VAC nominal), 50/60Hz Power consumption Approx. 20watts Temperature range 0°C to +50°C Protection rating IP40 Housing Black plastic for indoor drop-ceiling mount Dimensions See drawing Weight 1.3kg 1.5kg
digital zoom)

EDP No. Description 74088 System Keyboard with 3-axis Joystick, 12VDC/230VAC 74092 System Keyboard with Joystick, 5” Monitor, 12VDC/230VAC 75201 Matrix, Multiplexer and Telemetry Keyboard with Joystick, RS-485 Control 74057 Flush Mount Dome Housing, Smoked Bubble, 4.9” 74078 Pendant Mount Outdoor Dome Housing, Tinted Bubble 6.8”, 24VAC 74077 Pendant Mount Indoor Dome Housing, Clear Bubble 6.8”, 24VAC 74076 Pendant Mount Outdoor Dome Housing, Clear Bubble 6.8”, 24VAC 74075 Pendant Mount Indoor Dome Housing, Tinted Bubble 6.8”, 24VAC 74082 Pendant Mount Indoor Dome Housing, Clear Bubble 6.8”, 230VAC 74083 Pendant Mount Indoor Dome Housing, Tinted Bubble 6.8”, 230VAC 74084 Pendant Mount Outdoor Dome Housing, Clear Bubble 6.8”, 230VAC 74085 Pendant Mount Outdoor Dome Housing, Tinted Bubble 6.8”, 230VAC 74089 Converter RS-232/RS-485, Repeater RS-485 74095 Protocol Converter BiPhase to RS-422, 12VDC 70449 Voltage Supply Unit 230V/24VAC-5A, IP66 74094 Coax Telemetry Board for VPT-41/42, EDC/EDMC series, assembled 70457 Camera Connection Box, 230VAC Input, 24VAC-100W, 12VDC-1A Output
R2.3
R5
eneo® is a registered trademark of Videor Technical E. Hartig GmbH Exclusive distribution through specialised trade channels only.
VIDEOR TECHNICAL E. Hartig GmbH Carl-Zeiss-Straße 8 · 63322 Rödermark/Germany Tel. +49 (0) 6074 / 888-0 · Fax +49 (0) 6074 / 888-100
Technical changes reserved.
© Copyright by VIDEOR TECHNICAL 02/2007
Accessories
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No video | Verify that power is connected to all pieces of equipment in the system. Verify that the power switches are in the ON position. Check the video connections (see Figures 4). | p.29 | |
| Poor video quality | Check that the BNC connectors are inserted properly. Check the voltage level of the dome camera. Check that 8 pin cable is connected to the Keyboard. Check 8 pin cable for Keyboard is proprietary. (Cable for video is shielded.) Check termination of Video. | p.29 | |
| Dome cameras lose their positions. | Reset the cameras using the Dome configuration menus. Check that the dome cameras are inserted properly in the base. Check the voltage level of the dome camera. | p.29 | |
| Camera number does not match the multiplexer number. | Check the camera ID and insert the BNC cable into the proper input of the multiplexer. | p.29 | |
| Picture is torn when switching | Check Line Lock setting and adjust phase of L/L (see page 25). | p.29 |
Owners and our team usually reply within a day — and your question helps the next person too.