EN
Philips logo
Official user manual

Philips Video Camera

34 pages·2.6 MB·Digital Camera·PDF·ENDEFRITNLJA
Philips Video Camera
Table of Contents 80 sections Installation and Operating Manual · Fastrax · Dome Video Camera for Ceiling and Wall Mounting · EDC-141E, EDC-142E, EDC-143E, EDC-142E1, EDC-144E, EDC-142E2 · … ShowHide
Installation and Operating Manualp.1Fastraxp.1Dome Video Camera for Ceiling and Wall Mountingp.1EDC-141E, EDC-142E, EDC-143E, EDC-142E1, EDC-144E, EDC-142E2p.1Safety Instructionsp.31. Introductionp.31.1 Featuresp.32. Installation and Configurationp.52.1 Package Contentsp.52.2 Basic Configuration of Fastrax II Dome Camera Systemp.6STP AWG #24p.6BNCp.62.2.1 Single Multiplexerp.7AWG #24p.7BNC BNCp.72.2.2 Single User with Two Multiplexerp.82.2.3 Two Multiplexer with Slave Keyboard Controllerp.92.2.4 Two Multiplexer with Slave Keyboard Controller (method 2)p.102.3 Setting Unit for Terminationp.112.4 Setting Address (ID) of Dome Camerap.122.5 Setting Protocol of Dome Camerap.132.6 Connectionp.142.7 Getting Startedp.14RAM TESTp.14CHECK NO. : OK!p.14CHECK AAAA : OK!p.14CHECK 5555 : OK!p.14INIT TILT ORGIN SET OKp.14INIT PAN ORGIN SET OKp.14INIT CAMERA SET OKp.14001 PRESETp.14CAMERA TITLEp.14TITLEp.14CAMERA IDp.14EMPTY DATA !p.14INFORMATION DISPLAYp.14COMMAND ON WORKINGp.14T001 DOMEID:0001p.14ALARM:1 W_360.0,090.0p.14PAN & TILT DEGREEp.14ALARM DISPLAYp.14VIEW DIRECTIONp.143. Program and Operationp.153.1 Selecting Dome Camerap.153.2 Accessing On-Screen Menu Utilityp.15DOME MENUp.153.3 How to control On-Screen Menu Utilityp.15AUTO SCAN SETUPp.16SPEED (MODE): NORMAL1~NOMAL9, SLOW VECTOR, FAST VECTORp.16NORMAL1 (SLOWER) <––> NORMAL9 ( FASTER)p.163.5 Preset (Second Item of the Main menu / Shortcut: Prst )p.17PRESET SETUPp.173.6 Shortcut of Preset Programp.183.7 Tour (THIRD ITEM OF THE MAIN MENU / SHORTCUT: Tour )p.18PATTERN SETUPp.19SAVE AND EXIT (ESC TO CANCEL)p.19ALARM SETUPp.203.10 Area Title (Sixth Item of Main menu)p.20AREA TITLE SETUPp.203.11 Privacy Zone (Seventh Item of Main menu)p.21PRIVACY ZONE SETUPp.213.12 Camera (Eighth Item of Main menu)p.22CAMERA SETUPp.22EDC-141E EDC-142E EDC-144Ep.22EDC-143E EDC-142E1 EDC-142E2p.22FOCUS SETUPp.22MODE : AUTOp.22MODE : AUTO/MANUALp.22AF SENSITIVITY : HIGHp.22EXIT(ESC TO EXIT)p.22WB SETUPp.23EDC-143Ep.23EDC-142E1 EDC-142E2p.23AE SETUPp.24EXIT (ESC TO EXIT)p.24LINE LOCK SETUPp.25PHASE : 0~255p.25NIGHT SHOT SETUPp.25MODE : MANUAL / AUTO / GLOBALp.253.13 Dome Setup (Ninth Item of Main menu)p.26
Page 1 of the Philips Video Camera user manual — Installation and Operating Manual
Page 1 · click to enlarge
Page 1

Installation and Operating Manual

Fastrax

Dome Video Camera for Ceiling and Wall Mounting

EDC-141E, EDC-142E, EDC-143E, EDC-142E1, EDC-144E, EDC-142E2

Philips Video Camera — Installation and Operating Manual diagram (page 1)
Fig. 1 · Installation and Operating Manual
Page 2 of the Philips Video Camera user manual — Installation and Operating Manual
Page 2 · click to enlarge
Page 2
Page 2 of the Philips Video Camera user manual — Installation and Operating Manual
Page 3 of the Philips Video Camera user manual — 1. Introduction
Page 3 · click to enlarge
Page 3

Safety Instructions

  • Read these safety instructions and the operation manual first before you install and commission the camera.
  • Keep the manual in a safe place for later reference.
  • Protect your camera from contamination with water and humidity to prevent it from permanent damage. Never switch the camera on when it gets wet. Have it checked at an authorized service center in this case.
  • Never operate the camera outside of the specifications as this may prevent the camera functioning.
  • Do not operate the cameras beyond their specified temperature, humidity or power ratings. Operate the camera only at a temperature range of -10°C to +50°C and at a humidity of max. 90%.
  • To disconnect the power cord of the unit, pull it out by the plug. Never pull the cord itself.
  • Pay attention when laying the connection cable and observe that the cable is not subject to heavy loads, kinks, or damage and no moisture can get in. Do not attempt to disassemble the camera board from the dome.
  • Do not attempt to disassemble the camera board from the dome.
  • The warranty becomes void if repairs are undertaken by unauthorized persons. Do not open the camera housing. Maintenance and repair have to be carried out only by authorized service centers.
  • Do not use strong or abrasive detergents when cleaning the dome. Use a dry cloth to clean the dome surface. In case the dirt is hard to remove, use a mild detergent and wipe gently.

to take appropriate corrective action at his/her own expense.

1. Introduction

1.1 Features

The Fastrax II Keyboard Controller and the Fastrax II dome cameras make up the building blocks for any surveillance/security system. Using multiple Keyboard Controllers and multiple dome cameras, no place is too large for monitoring. Extensible and flexible architecture facilitates remote control functions for a variety of external switching devices such as multiplexers and DVRs.

  • Built-in 18x (23x,25x, 22x, 26x) times optical power zoom camera with True Night Shot function
  • 240 Preset positions
  • 8 Tours consist of Preset, Pattern, Auto-Scan and Tour itself can be programmed over 300 functions and Preset location. While moving, each Preset scan can be watched in smooth Vector Scan mode.
  • 8 Auto Scan including vector scan (and 1 endless Auto Scan at EDC-144E)
  • 4 Pattern (240seconds)
  • 8 Privacy zone
  • 8 Alarm input / 4 Aux out (NC & NO)
  • Variable speed from 0.1°/sec to 90°/sec
  • Turbo speed is Max 360°/sec with Ctrl key pressed
  • Maximum speed is inversely proportional to the zoom ratio
  • Maximum speed is 380°/sec when preset command.
  • Programmable user preferences (alarm, preset, title, etc.)
  • Up to 999 selectable camera addresses
  • Built-in RS-485/422 receiver driver
  • Clear bubble with black liner (shelter) for concealing the camera
  • Optional Tinted Bubble, Indoor & Outdoor pendant housing with heater & blower, Indoor Flush Mount, Parapet mount & Roof Top mount
Page 4 of the Philips Video Camera user manual — Safety Instructions
Page 4 · click to enlarge
Page 4
Philips Video Camera — Safety Instructions diagram (page 4)
Fig. 2 · Safety Instructions

up to 255 multiplexer

Alarm Input (up to 8)

up to 99 DVR

Alarm Output (up to 4)

up to 32 cameras

up to 3 Slave keyboards

Figure 1 - Typical System Configuration

Philips Video Camera — Safety Instructions diagram (page 4)
Fig. 3 · Safety Instructions

Remove window Assemble bubble ring ass’y

Figure 2 - Assemble bubble ring ass’y

Show 10 more labels / short text on this page
<Sensor> · <Siren> · <Flashing light> · J-box · Master keyboard · push · bubble ring ass’y · remove camera window · screw · push
Page 5 of the Philips Video Camera user manual — 2. Installation and Configuration
Page 5 · click to enlarge
Page 5

2. Installation and Configuration

2.1 Package Contents

The package contains the following:

1x Fastrax II E (Dome Camera)

1x Instruction Manual (This Document)

3x Assembly Screws for Attaching Fastrax II E

Different version will not support alarm input and output.

The dome camera is for use in surface mounting applications and the mounting surface should be capable of supporting loads up to 10lb (4.5kg).

The dome camera’s base should be attached to a structural object, such as a hard wood, wall stud or ceiling rafter that supports the weight of the dome camera.

Philips Video Camera — 2. Installation and Configuration diagram (page 5)
Fig. 4 · 2. Installation and Configuration

Align extruded tap in the base to the keyhole on the PCB in the body

Figure 3 - Installation

Show 10 more labels / short text on this page
1x Bubble Ring · 3x Plastic Anchor · 1x 10Pin Connector · 2x 12Pin Connector · Cable entry · Surface (ceiling) · Lock Unlock · Base · Body · Lock
Page 6 of the Philips Video Camera user manual — BNC
Page 6 · click to enlarge
Page 6

2.2 Basic Configuration of Fastrax II Dome Camera System

Philips Video Camera — 2.2 Basic Configuration of Fastrax II Dome Camera System diagram (page 6)
Fig. 5 · 2.2 Basic Configuration of Fastrax II Dome Camera Sy…

STP AWG #24

1 ~ 2 Alarm input

BNC

3 ~ 4 Alarm input

RS-485 Half Duplex modeRX+, RX–
RS-422 Simplex mode(RX+), (RX–) Duplex mode: (TX+), (TX–), (RX+), (RX–)

BNC

J-Box (Back) J-Box (Front)

Up to 128 Dome cameras including 32 alarm mode can be connected at DOME2 port.

DATA2 port should be connected in case that DOME2 port or DVR port are used.

Figure 4- Basic installation diagram

The dome camera must be installed by qualified service personnel in accordance with all local and federal electrical and building codes. The system should be installed according to Figures 4 through 9.

Show 18 more labels / short text on this page
Power 24VAC · Alarm output · 1 ~ 4 · Power 24VAC · Sensor Alarm input · up to 8 · Dome1+ · Siren · Dome1– · Light Alarm output · Monitor · up to 4 · Alarm output · 5 ~ 8 · unshielded cable · unshielded cable · Rear · Keyboard controller
Page 7 of the Philips Video Camera user manual — AWG #24
Page 7 · click to enlarge
Page 7

2.2.1 Single Multiplexer

Power 24VAC Power 24VAC

Philips Video Camera — 2.2.1 Single Multiplexer diagram (page 7)
Fig. 6 · 2.2.1 Single Multiplexer

AWG #24

BNC

BNC BNC

RS-485 (–) Pin No. 4 RS-485 (+) Pin No. 6

J-Box (Back) J-Box (Front)

Figure 5 - Single Multiplexer

Show 6 more labels / short text on this page
Power 24VAC · Spot Monitor · Main Monitor · Multiplexer · Rear · Keyboard controller
Page 8 of the Philips Video Camera user manual — AWG #24
Page 8 · click to enlarge
Page 8

2.2.2 Single User with Two Multiplexer

Power 24VAC Power 24VAC

Philips Video Camera — 2.2.2 Single User with Two Multiplexer diagram (page 8)
Fig. 7 · 2.2.2 Single User with Two Multiplexer

AWG #24

BNC

BNC

BNC

BNC

RS-485 (–) Pin No. 4 RS-485 (+) Pin No. 6

J-Box (Back) J-Box (Front)

Spot output of the first multiplexer to be connected to 16th input of the second multiplexer.

And first spot output of the 2nd multiplexer to be connected to the spot monitor. You will see tthe picture of the selected camera (1-31) on spot monitor by selecting camera No. + Cam.

Figure 6 - Two Multiplexer

Show 8 more labels / short text on this page
Power 24VAC · 1st Main Monitor · Spot Monitor · 2nd Main Monitor · 1st Multiplexer · 2nd Multiplexer · Rear · Keyboard controller
Page 9 of the Philips Video Camera user manual — BNC
Page 9 · click to enlarge
Page 9

2.2.3 Two Multiplexer with Slave Keyboard Controller

Power 24VAC Power 24VAC

Philips Video Camera — 2.2.3 Two Multiplexer with Slave Keyboard Controller diagram (page 9)
Fig. 8 · 2.2.3 Two Multiplexer with Slave Keyboard Controller

AWG #24

BNC

2nd Main Monitor Spot Monitor

Spot Monitor for Master K/B

BNC

BNC

BNC

RS-485 (–) Pin No. 4 RS-485 (+) Pin No. 6

J-Box (Back) J-Box (Front)

Spot output 1 of the first multiplexer to be connected to 16th input of the second multiplexer.

n: User, Spot out of nth to be connected to (17-n)th camera input of the 2nd multiplexer. nth spot out of the 2nd multiplexer to be connected to the nth spot monitor. Each user will see the picture of the selected camera (1 ~ (31-n)) on nth spot monitor of the Mux 2 by selecting camera No. + Cam.

Figure 7 - Two Multiplexer with Slave Keyboard Controller

Show 9 more labels / short text on this page
Power 24VAC · 1st Main Monitor · for Slave K/B · 1st Multiplexer · 2nd Multiplexer · Rear · Rear · Keyboard controller Master · Keyboard controller Slave
Page 10 of the Philips Video Camera user manual — BNC
Page 10 · click to enlarge
Page 10

2.2.4 Two Multiplexer with Slave Keyboard Controller (method 2)

Power 24VAC Power 24VAC

Philips Video Camera — 2.2.4 Two Multiplexer with Slave Keyboard Controller (method 2) diagram (page 10)
Fig. 9 · 2.2.4 Two Multiplexer with Slave Keyboard Controller…

AWG #24

BNC

2nd Main Monitor Spot Monitor

Spot Monitor for Master K/B

BNC

BNC

BNC

RS-485 (–) Pin No. 4 RS-485 (+) Pin No. 6

J-Box (Back) J-Box (Front)

Spot output 1 of the first multiplexer to be connected to 16th input of the second multiplexer.

n: User, Spot out of nth to be connected to (17-n)th camera input of the 2nd multiplexer. nth spot out of the 2nd multiplexer to be connected to the nth spot monitor. Each user will see the picture of the selected camera (1 ~ (31-n)) on nth spot monitor of the Mux 2 by selecting camera No. + Cam.

Figure 8 - Two Multiplexer with Slave Keyboard Controller (method 2)

Show 9 more labels / short text on this page
Power 24VAC · 1st Main Monitor · for Slave K/B · 1st Multiplexer · 2nd Multiplexer · Rear · Rear · Keyboard controller Master · Keyboard controller Slave
Page 11 of the Philips Video Camera user manual — 2.3 Setting Unit for Termination
Page 11 · click to enlarge
Page 11
Philips Video Camera — 2.3 Setting Unit for Termination diagram (page 11)
Fig. 10 · 2.3 Setting Unit for Termination

Addresses (ID) and protocol

Figure 9 - Layout of Switches

2.3 Setting Unit for Termination

The device which is connected at end of line, whether it is a dome camera or keyboard controller, must have the cable for communication terminated by setting the appropriate DIP switch. Without proper termination, there is potential for control signal errors. Total length of the cable for communication should not exceed 1.2km.

SW112 TerminatedONON Not terminatedOFFOFF

Figure 10 - Setting Unit for Termination

Termination switches · selection switches

Page 12 of the Philips Video Camera user manual — 2.4 Setting Address (ID) of Dome Camera
Page 12 · click to enlarge
Page 12
Philips Video Camera — 2.4 Setting Address (ID) of Dome Camera diagram (page 12)
Fig. 11 · 2.4 Setting Address (ID) of Dome Camera

Figure 11 - Termination Diagram

2.4 Setting Address (ID) of Dome Camera

To prevent damage, each dome camera must have a unique address (ID). When installing multiple dome cameras using a multiplexer, it is suggested that the dome camera address matches the multiplexer port number.

If you wan to set the address more than 999, you should connect the service provider.

Example: Port 1 = Dome 1, Port 2 = Dome 2 ... Port 16 = Dome 16. If more than 16 dome cameras are installed using two or more multiplexers, ID of the dome camera should be ID of MUX x No. of camera IN. (e.g. multiplexer ID= n, Camera IN= m then ID of Dome =16x(n-1)+m )

Refer to Figures 4-5 for setting the dome camera address (ID) and protocol selection.

Philips Video Camera — 2.4 Setting Address (ID) of Dome Camera diagram (page 12)
Fig. 12 · 2.4 Setting Address (ID) of Dome Camera
Dome IDS3S2S1 1001 2002 ………… 999999

Beyond ID 999, contact your service provider.

Figure 12 - Setting Address (ID) of Dome Camera

Page 13 of the Philips Video Camera user manual — 2.5 Setting Protocol of Dome Camera
Page 13 · click to enlarge
Page 13

2.5 Setting Protocol of Dome Camera

If a dome camera is to be installed with a Fastrax keyboard controller, select F2 protocol.

Consult service personnel if a dome camera is installed with device other than a keyboard controller.

Philips Video Camera — 2.5 Setting Protocol of Dome Camera diagram (page 13)
Fig. 13 · 2.5 Setting Protocol of Dome Camera

D1 S4-1 Enable Disable Alarm D2 S4-2 PAL NTSC NTSC/PAL D3 S4-3 Endless D4 S4-4 RS-422 RS-485 RS-422/RS-485

Philips Video Camera — 2.5 Setting Protocol of Dome Camera diagram (page 13)
Fig. 14 · 2.5 Setting Protocol of Dome Camera
Philips Video Camera — 2.5 Setting Protocol of Dome Camera diagram (page 13)
Fig. 15 · 2.5 Setting Protocol of Dome Camera

Off Off Off Fastrax, Pelco D&P, Dynacolor, Ernitec &

Philips G3 Protocol (Default) Off Off On Reserved Off On Off Sensormatic RS-422 Off On On Reserved On Off Off Vicon Protocol On Off On Reserved On On Off Dynacolor On On On Reserved

Philips Video Camera — 2.5 Setting Protocol of Dome Camera diagram (page 13)
Fig. 16 · 2.5 Setting Protocol of Dome Camera

Off Off Off 2400 bps Off Off On 4800 bps Off On Off 9600 bps (Default) Off On On 19200 bps On Off Off 38400 bps On Off On 57600 bps On On Off 115200 bps

Figure 13 – Protocol Selection Switches

Unless Baud rate match, universal protocol will not work.

Philips Video Camera — 2.5 Setting Protocol of Dome Camera diagram (page 13)
Fig. 17 · 2.5 Setting Protocol of Dome Camera

Off Off Default cameras (Default) Off On Reserved On Off Reserved On On Reserved

Page 14 of the Philips Video Camera user manual — 001 PRESET
Page 14 · click to enlarge
Page 14

2.6 Connection

  • Connecting to the RS-485/-422

The dome camera can be controlled remotely by an external device or control system, such as a control keyboard, using RS-485 half-duplex, RS-422 duplex or simplex serial communications signals. Connect Marked Rx+, Rx- to Tx+ and Tx- of the RS-485 control system.

If control system is RS-422, connect Rx+ (Tx+), Rx+ (Tx-) and Rx+, Rx- of the dome camera to Tx+, Tx- and Rx+, Rx- of the control device respectively.

  • Connecting Video out connector

Connect the video out (BNC) connector to the monitor or video input.

  • Connecting Alarms

AL1 to 8 (Alarm In)

You can use external devices to signal the dome camera to react on events. Mechanical or electrical switches can be wired to the AL (Alarm In) and GND (Ground) connectors. See Chapter 3 - Program and Operation for configuring alarm input.

Connect the ground side of the Alarm input and/or alarm output to the GND connector.

NC(NO)1 TO 4 (Normal Close or Normal Open: Alarm Out)

The dome camera can activate external devices such as buzzers or lights. Connect the device to the NC(NO) (Alarm Out) and COM (Common) connectors. See Chapter 3 - Program and Operation for configuring alarm output.

  • Connecting the Power

Connect the power of 24VAC 850mA to the dome camera.

Use certified / Listed Class 2 power supply transformer only.

2.7 Getting Started

Once installed apply power to the dome camera. The dome camera will start a initializing sequence. When configuration is done, the following information is displayed on the keyboard controller’s LCD.

RAM TEST

CHECK NO. : OK!

CHECK AAAA : OK!

CHECK 5555 : OK!

FASTRAX II E Vx.xxx

WAIT DOME SETTING.

INIT TILT ORGIN SET OK

INIT PAN ORGIN SET OK

INIT CAMERA SET OK

PRESET No.

001 PRESET

CAMERA TITLE

TITLE

CAMERA ID

EMPTY DATA !

INFORMATION DISPLAY

COMMAND ON WORKING

T001 DOMEID:0001

ALARM:1 W_360.0,090.0

PAN & TILT DEGREE

ALARM DISPLAY

VIEW DIRECTION

GND (Ground) · CAMERA TYPE xxxx · OSD Position

Page 15 of the Philips Video Camera user manual — 3.3 How to control On-Screen Menu Utility
Page 15 · click to enlarge
Page 15

3. Program and Operation

3.1 Selecting Dome Camera

Before you program or operate a dome camera, you must select the dome camera by pressing the dome camera No. + CAM successively.

Example: Pressing 1, 0 and CAM key sequentially will select dome camera 10. The selected dome camera ID will be displayed on the LCD monitor of the keyboard controller.

3.2 Accessing On-Screen Menu Utility

You can call up the On-screen menu utility on your monitor by pressing MENU key on the keyboard controller, the following On-screen menu utility will appear:

DOME MENU

AUTO SCAN PRESET TOUR PATTERN ALARM AREA TITLE PRIVACY ZONE CAMERA DOME SETUP EXIT(ESC TO EXIT)

3.3 How to control On-Screen Menu Utility

MENU Call on On-screen menu utility

Go into the sub-menu items. Execute the command (exit) Change value. Navigate through the menu items.

Joystick left or right

Joystick up or down Navigate through the menu items.

Joystick down Finish editing title. Same effect as Enter key

Zoom handle twist Change value. Enter editing title mode at Preset menu.

CTRL + Joystick PTZ control of the selected camera

Action Function · ESC Escape (EXIT)

Page 16 of the Philips Video Camera user manual — SPEED (MODE): NORMAL1~NOMAL9, SLOW VECTOR, FAST VECTOR
Page 16 · click to enlarge
Page 16

3.4 Auto Scan (First Item of the Main menu / Shortcut: Scan)

The Auto scan supports up to 8 programmed angles at user-programmable speeds. Follow these steps to program Auto Scan:

AUTO SCAN SETUP

SCAN 01 : AUTOSCAN01 SPEED(MODE) : FAST VECTOR START ANGLE : 127.1, 027.7 X7 END ANGLE : 157.7, 080.7 X13 SCAN DIR. : CCW SWAP : OFF SAVE AND EXIT (ESC TO CANCEL)

HOLD DOWN CTRL KEY WHILE SELECT POSITION.

SPEED (MODE): NORMAL1~NOMAL9, SLOW VECTOR, FAST VECTOR

NORMAL1 (SLOWER) <––> NORMAL9 ( FASTER)

SLOW VECTOR, FAST VECTOR: Move from start point to end point including tilt and zoom simultaneously and linearly. In case of EDC-143E, EDC-142E1 and EDC-142E2, zoom is fixed at more wide angle and the zoom magnification information is not displayed.

1. Press the Scan key to enter Auto Scan menu directly. Or press the Menu key to display the main menu on the monitor. Scroll to Auto Scan and push the Joystick to the right.
2. Select an Auto Scan number by pushing the Joystick left or right.
3. Twist the Joystick to enter the title by scrolling through the alphanumeric characters and pushing the handle to the right or left to move to the next space. Press Enter key or push the Joystick down to finish title mode. Press HOME key in order to delete stored alphanumeric characters.
4. Push the Joystick downward to select „Speed” and set the speed by twisting the Ctrl/PGM keyclockwise or counterclockwise or moving the Joystick left and right to select the auto scan speed.
5. When finish entering the title and speed, select „START ANGLE” with the Joystick . Hold down the Ctrl/PGM key while selecting the start position and zoom using the Joystick . Current panning position will be displayed. Release Ctrl/PGM key to complete the selection of the start position.
6. Push the Joystick downward to select „END ANGLE.” Hold down the Ctrl/PGM key while moving the Joystick to select the end position and zoom. The end position angles should be larger than start position. Release the Ctrl/PGM key to complete the selection of the end position.
7. Select Save and Exit by pushing the Joystick to the right. Press ESC to exit the program without saving.

position at a specific speed. (Pan only)

a. Before entering the Auto Scan menu, select a preset position as a starting point for Auto Scan.

Example: 2 + Prst and do step 1 to 4. Instead of step 5, just press the Ctrl/PGM key at the start angle position, the current position will be displayed as a start position.

b. Save and exit from the menu.

c. In normal mode, call a preset to be the end point of scan. Press 3 + Prst then press Scan key to enter the Auto Scan menu. Move the cursor position to END ANGLE. Just press Ctrl/PGM key at the end angle position. Do step 7.

Example: Preset 001>002>003>004>005>006, Auto Scan 01 starts at 002, ends at 003, Auto Scan 02 starts at 005, ends at 006. Tour 001, 002, A01, 004, A02.

1 2 2~3 4 5~6 1 2 2~3

Where : Quick move, ~ : Programmed speed by Auto Scan.

Page 17 of the Philips Video Camera user manual — PRESET SETUP
Page 17 · click to enlarge
Page 17

3.5 Preset (Second Item of the Main menu / Shortcut: Prst )

If you need to view specific locations routinely, you should program presets. A preset is a programmed video scene with automatic pan, tilt, zoom, focus and iris settings. Once programmed, entering the number and pressing a Preset button on your controller automatically calls up the preset. In addition, presets may be assigned to alarm actions or as the „home” position for the dome camera. As many as 240 presets, whose positions are saved in the dome’s non- volatile memory, may be programmed.

There are three pages of preset menu, each page can hold 80 presets. Pages can be scrolled by pushing the Joystick to the left or right on the first or last No. of Preset.

PRESET SETUP

NO. 001xxxxxxxxxxxxxxxx FOCUS : AUTO/ MANUAL IRIS : AUTO/ MANUAL DWELL : 03~99 (Sec)

1234567890 1234567890 00 * * * ===== 01========== 02========== 03========== 04========== 05========== 06========== 07========== JOY-LEFT TO PREV. PAGE SAVE AND EXIT(ESC TO CANCEL)

x16 digits of title for preset label
=blank preset position
*position has the preset

: Current cursor position

Follow steps below to store the Preset positions:

1. Press Menu to display the main menu. Select the Preset option by using the Joystick to the right. (Press Prst to go directly to the Preset menu without going through the main menu.)
2. Select the blank preset position to be stored by pushing the Joystick up, down, right, or left.
3. The position, which is marked with * , already has the preset view assigned. To review the stored preset, press Prst key on the The camera will show the stored preset view.
4. After selecting a blank position, press and hold Ctrl/PGM , use the Joystick to control the direction of the camera and lens. ( Ctrl+Joystick )
5. After aiming the camera (view direction and lens control), release Ctrl/PGM . Then twist the Joystick handle or Press Tele or Wide Key to store the selected view. The position number will be displayed and the user will be prompted to enter a preset title.
6. Enter the title for the preset position using the Joystick . (Rotate handle clockwise and counterclockwise or press Tele or Wide Key to scroll through the alphanumeric characters, push the handle to right or left to select next or previous digit.)
7. When you are finished entering the title, push the Joystick downward. Set the focus by pushing the Joystick to the right or left. Set the IRIS value in the same manner as the focus.
8. Move to the DWELL setting by pushing the Joystick down. Twist the Joystick clockwise or counterclockwise to increase or decrease dwell time of the preset position.
9. To select the next page of presets, scroll the page by pushing the Joystick to the left on the first and last columns of the menu.
10. Repeat steps 2 through 7 for each additional preset position.
11. To edit the title of a stored preset, use the Joystick to position the cursor on the desired preset position. Press the Prst key to recall the stored preset. Twist the zoom handle clockwise to enter the preset title, focus and IRIS. Preset titles are useful with short cut preset programming. Refer to Shortcut programming below.
12. Select Save and Exit by pushing the Joystick to the right. Press ESC to exit the Preset menu without saving.
Page 18 of the Philips Video Camera user manual — 3.7 Tour (THIRD ITEM OF THE MAIN MENU / SHORTCUT: Tour )
Page 18 · click to enlarge
Page 18

3.6 Shortcut of Preset Program

Select a view to be stored (direction of the camera, zoom and focus), then press No. (1 to 240), and then press Pgm, Prst subsequently. The current view will be stored to the selected preset number if position is empty. If selected preset number is not empty, „PRESET EXISTING” message will be displayed on the monitor and ask to overwrite.

Example: 1, 0, 1 + Pgm + Prst will store current view as preset No. 101. In this case, focus and Iris mode will be programmed as Auto, dwell time will be set

to 3 sec.

3.7 Tour (THIRD ITEM OF THE MAIN MENU / SHORTCUT: Tour )

There are 8 programmable Tours. Each Tour consists of up to 42 Preset positions, Patterns, Scans or other Tours (second-level). Using second-level Tours, it can be expanded to over 300 functions in a single Tour. However Tours in second level Tour will be ignored when called by a Tours. The following example illustrates this concept:

If Tour1 has Preset1 Preset2 Tour2 Tour3 and

Tour2 has Preset3 Preset4 Preset5 Tour4 and

Tour3 has Preset6 Pattern1 and

Tour4 has Preset7.

Tour1 executes as follows:

Preset1 Preset2 Preset3 Preset4 Preset5 Preset6 Pattern1

Preset1 ... (Repeat)

Tour2 executes as follows:

Preset3 Preset4 Preset5 Preset7 Preset3 ... Repeat

(Tour4 is still valid if called directly from Tour2.)

GUARD TOUR SETUP TOUR 01xxxxxxxxxxxxxxxx SCAN TYPE : NORMAL DWELL : 03

=== === 003 === A08 === T02 === 001 === T08 === SAVE AND EXIT (ESC TO CANCEL) PRESS FUNCTION KEY AND ROTATE JOYSTICK TO SELECT NUMBER.

xxxxx16 digits of title for tour label
===blank preset position
SCAN TYPEMax (Normal)/ Slow V. Scan/ Fast V. Scan
DWELL03-99 Sec
3. Preset 003 (1~240)
A08Auto Scan 08 (1~8)
P01Pattern 01 (1~4)
T02Tour 02 (1~8)

Follow the steps below to program the Tours:

1. Press Menu to display the main menu on the monitor. Scroll to Tour and push the Joystick to the right to enter the Tour menu. Or just press the Tour key on the keyboard.
2. Choose an empty location to be programmed by pushing the Joystick up, down, right, or left.
3. To see a stored preset view, use the Joystick to move the cursor to a stored position. By pressing Prst key, the camera will move to the stored Preset view.
Page 19 of the Philips Video Camera user manual — SAVE AND EXIT (ESC TO CANCEL)
Page 19 · click to enlarge
Page 19
4. To add a stored preset as a Tour, twist the Zoom handle or press Zoom Key (Programmed preset will scroll). To remove a stored preset from the Tour, press the Home key, blank position mark (===) will be displayed. You can overwrite the programmed position.
5. To place functions other than preset, press Tour, Ptrn, or Scan for Tour, Pattern or Auto Scan respectively and the use zoom handle or key to select No.
6. Repeat Step 2 through 5 for each desired position. Each title will be displayed on top of the line.
7. Up to 36 Presets, Tours, Patterns Scans can be selected for a Tour. You can expand the Tour sequence by calling other programmed tours. Push the Joystick handle to right or left while the cursor is on the top of the line (TOUR 01) to select another page of the Tour menu. (TOUR 01)
8. You can enter a title for the selected Tour by twisting the Joystick while the cursor is on the top of the line (TOUR 01). Rotate the handle clockwise or counterclockwise to scroll through the alphanumeric characters. Push the handle to the right or left to select the next or previous digit.
9. Select Save and Exit by pushing the Joystick to the right. Press ESC to exit the program without saving.

you can make the camera travel from a preset position to another preset position at a specific speed.

Example: Preset 001>002>003>004>005>006, Auto Scan 01 starts at preset 002, ends at preset 003, Auto Scan 02 starts at preset 005, ends at preset

006; Tour 001, 002, A01, 004, A02.

1 2 2~3 4 5~6, repeat

whereQuick move, ~ : Programmed speed

3.8 Pattern (Fourth 4 Item of the Main menu / Shortcut: Ptrn)

The Pattern feature records user control of the selected dome camera for up to 240 seconds. Up to four 4 patterns can be stored and played back by pressing No.+ Ptrn keys subsequently.

PATTERN SETUP

NO. TITLE SEC 01xxxxxxxxxxxxxxxx 000 02: xxxxxxxxxxxxxxxx 041 03: xxxxxxxxxxxxxxxx 010 04: xxxxxxxxxxxxxxxx 020 TOTAL: 071

SAVE AND EXIT (ESC TO CANCEL)

HOLD DOWN CTRL KEY WHILE RECORDING.

Follow steps below to program the Pattern:

1. Press Menu key to display the main menu on the monitor.
2. Scroll down to PATTERN and push the Joystick to the right. Or simply press the Ptrn key rather than use the Main Menu.
3. Select the empty Pattern number to be programmed by pushing the Joystick up or down. If last column is not 000, a pattern has already been recorded. Patterns can be over written.
4. Press and hold down the Ctrl/PGM key while controlling the camera direction and zoom with the Joystick . Your controls will be automatically recorded until you release the Ctrl/PGM key. You can repeat this procedure until you have the pattern you want. Previously recorded patterns will be overwritten each time you do this.
5. Scroll down to the Save and Exit option and push the Joystick to the right to save and exit.
6. You can title the selected Pattern by twisting the Joystick . Rotate the handle clockwise or counterclockwise to scroll through the alphanumeric characters, push the handle to right or left to select next or previous space.
7. Pressing ESC will not save your information and exits to the previous mode.
7. Press the Home key at any programmed position to delete the programmed pattern.
Page 20 of the Philips Video Camera user manual — AREA TITLE SETUP
Page 20 · click to enlarge
Page 20

3.9 Alarm (This menu shows on only specific model, Fifth Item of Main menu)

ALARM SETUP

NO PRI PRS IN OUT HLD LATCH 01 1 001 OFF OFF 03 OFF 02 8 001 OFF OUT1 03 OFF 03 1 240 NO OUT1 03 OFF 04 2 001 NC OUT4 03 OFF 05 1 001 OFF OFF 03 OFF 06 8 001 OFF OUT1 03 OFF 07 1 240 NO OUT1 03 OFF 08 2 001 NC OUT4 03 OFF SAVE AND EXIT (ESC TO CANCEL)

NOAlarm input number

PRI : Lower No. has higher priority, Equal priority alarms will be serviced repeatedly.

PRS : Stored preset number to be called by alarm.

INNO/NC - normally open /Closed OFF - ignore

OUT : OUT1~OUT4 - Relay out 1,2,3,4, OFF - No output.

HLDAlarm will be held for programmed time (01 to 99 seconds)

LATCH : ON - Shows all alarms including past alarm, OFF - Shows activated alarms only.

There is one „0” PRIO which is the highest priority. „0” priority can choose Autoscan, Pattern or Tour. When responding „0” priority alarm, there is no respond other alarm until finishing „0” priority action

1. Press Menu to display the main menu on the monitor. Select the Alarm option by pushing the Joystick up or down and push to right to enter the detail menu.
2. Select the alarm input number by pushing the Joystick up or down and select the column you wish to setup. Selected position will be highlighted.
3. Select the Preset, Status of Input (NC/NO/OFF), and Output (OUT1~4/OFF) by pushing the Joystick to the right or to the left.
4. To increase or decrease the preset number or to change the status or output number, twist the Joystick clockwise or counterclockwise. In case of preset, programmed preset number will be scrolled.
5. Select the Save and Exit option by pushing the Joystick up or down. Save and exit the program by pushing the Joystick to the right. Press ESC to exit the program without saving.

3.10 Area Title (Sixth Item of Main menu)

Enter a specific name on programmed angle between START and END. For the screen below, when the camera points at an angle between 124.3° to 359.5°, ABC will be displayed on the screen.

AREA TITLE SETUP

NO TITLE START END 01 ACB 124.3 359.5 02 xxxxxxxxxxxxxxxx ===== ===== 03 xxxxxxxxxxxxxxxx ===== ===== 04 xxxxxxxxxxxxxxxx ===== ===== 05 xxxxxxxxxxxxxxxx ===== ===== 06 xxxxxxxxxxxxxxxx ===== ===== 07 xxxxxxxxxxxxxxxx ===== ===== 08 xxxxxxxxxxxxxxxx ===== ===== SAVE AND EXIT (ESC TO CANCEL) HOLD DOWN CTRL KEY TO MOVE

PANNING AND SET AREA ANGLE.

Page 21 of the Philips Video Camera user manual — SAVE AND EXIT (ESC TO CANCEL)
Page 21 · click to enlarge
Page 21

Pages can be scrolled through by pushing the Joystick to the left or right on the first or last column of the menu. Pushing the Joystick to left on the „NO” column (01 ~ 08) of the menu to scroll to the previous page. Push the Joystick to right on the „END” column to go to the next page.

1. Press Menu to display the main menu on the monitor. Select the Area Title option by pushing the Joystick up or down and push to right to enter the detail menu.
2. Select the area number by pushing the Joystick up or down. Select Start, End or number column to be set by pushing the handle to the right or left. The selected column will be highlighted.
3. To enter area title, select the number column and rotate the handle clockwise or counterclockwise. You can select alphanumeric characters by rotating the handle. Move to the next character by pushing the Joystick to the right. To finish entering the title, push the Joystick down.
4. To adjust panning limit, press the Ctrl/PGM key and hold down. Then use the Joystick to aim the desired direction. The end limit must be in an increasing direction. (Start < End).
5. When you press the Ctrl/PGM key, the current position of the pan will be displayed in the highlighted column. With this feature, you can easily set the next start point as the previous end point.
6. Select the Save and Exit option by pushing the Joystick up or down. Save and exit the program by pushing the Joystick to the right. Press ESC to exit the program without saving.
6. Pressing the Home key will delete programmed data. (Angles will be turned ==== immediately.)

3.11 Privacy Zone (Seventh Item of Main menu)

Hide up to 8 unwanted views in a camera.

PRIVACY ZONE SETUP

NO TITLE METHOD 01 xxxxxxxxxxxxxxxx ON BLOCK 02 xxxxxxxxxxxxxxxx OFF V.OFF 03 xxxxxxxxxxxxxxxx NONE ==== 04 xxxxxxxxxxxxxxxx NONE ==== 05 xxxxxxxxxxxxxxxx NONE ==== 06 xxxxxxxxxxxxxxxx NONE ==== 07 xxxxxxxxxxxxxxxx NONE ==== 08 xxxxxxxxxxxxxxxx NONE ====

SAVE AND EXIT (ESC TO CANCEL)

1. Press Menu to display the main menu on the monitor. Select the Privacy Zone option by pushing Joystick up or down and push to right to enter the detail menu.
2. Select the privacy zone number by pushing the Joystick up or down.
3. To enter the zone name, rotate the handle clockwise or counterclockwise. You can select alphanumeric characters by rotating the handle. Move to the next character position by pushing the Joystick to the right. To finish entering the title, push the Joystick down or press the Enter key.
4. To adjust the „marked” (privacy) area, press and hold down the Ctrl/PGM key and then use the Joystick (direction and zoom) until you get desired view. Release the key, the right column will be set to ON.
5. You can overwrite an existing zone. Use the Home key to delete the marked zone, or push the Joystick to the right or left to turn the stored zone On or Off.
6. Select the Save and Exit option by pushing the Joystick up or down. Save and exit the program by pushing the Joystick to the right. Press ESC to exit the program without saving.
6. Press the Home key to delete programmed privacy zone.
Page 22 of the Philips Video Camera user manual — EDC-141E EDC-142E EDC-144E
Page 22 · click to enlarge
Page 22

3.12 Camera (Eighth Item of Main menu)

CAMERA SETUP

FOCUS CONTROL WB CONTROL AE CONTROL LINE LOCK CONTROL SHARPNESS : 9 BACK LIGHT : OFF DIGITAL ZOOM : OFF (2x/4x/ MAX) NIGHT SHOT CONTROL (optional) SAVE AND EXIT (ESC TO CANCEL)

SHARPNESS The higher the value, the more edges in the picture will be enhanced.

EDC-141E, EDC-142E, EDC-144E0~15 EDC-143E: 0~63 EDC-142E1, EDC-142E2: 0 ~ 20

BACK LIGHT Objects in front of bright backgrounds will be clearer with BLC ON.

DIGITAL ZOOM OFF: Zoom range is limited to the optical.

2x : Zoom is extendable up to 2x of digital range.

4x : Zoom is extendable up to 4x of digital range.

MAXZoom is extendable Max digital Zoom range. EDC-142E1, EDC-142E2: OFF, MAX

NIGHT SHOT CONTROL (Not at EDC-142E1)

  • FOCUS CONTROL

EDC-141E EDC-142E EDC-144E

EDC-143E EDC-142E1 EDC-142E2

FOCUS SETUP

FOCUS SETUP

MODE : AUTO

MODE : AUTO/MANUAL

AF SENSITIVITY : HIGH

EXIT(ESC TO EXIT)

EXIT(ESC TO EXIT)

MODE: AUTO / MANUAL Use manual mode in normal use.

AF SENSITVITY: HIGH / LOW (only EDC-141E, EDP No. 74086; EDC-142E, EDP No. 74081; EDC-144E, EDP No. 74100)

HIGH: Use this option when shooting fast motion.

LOW: Offers better focus stability. In low luminance conditions, Auto Focus stops operation even when brightness changes, enabling stable

images of moving objects.

  • CAUTION: Avoid continuous, 24-hour use of the auto focus. This may cause the lens to malfunction, and it will shorten the lifespan of the lens.
Page 23 of the Philips Video Camera user manual — EDC-142E1 EDC-142E2
Page 23 · click to enlarge
Page 23
  • WB (white balance) CONTROL

EDC-141E EDC-142E EDC-144E

WB SETUP

MODEAUTO R GAIN : 210 B GAIN : 155 EXIT (ESC TO EXIT)

MODE : MANUAL / AUTO / INDOOR / OUTDOOR / ONE PUSH / ATW RGAIN : 0 ~ 255 BGAIN : 0 ~ 255

Use the ATW mode for normal use.

RGAIN / BGAIN modes are controllable only in MANUAL Mode.

Push the Joystick to the right or left to change.

then holds that position until the next rotating the Joystick handle.

EDC-143E

WB SETUP

MODEAUTO/MANUAL R GAIN : 133 B GAIN : 133 EXIT (ESC TO EXIT)
MODEMANUAL / AUTO RGAIN : 0 ~ 255 BGAIN : 0 ~ 255

Use the AUTO mode for normal use.

RGAIN / BGAIN modes are controllable only in MANUAL Mode.

Push the Joystick to the right or left to change.

EDC-142E1 EDC-142E2

WB SETUP

MODEAWB R GAIN : 85 B GAIN : 85 EXIT (ESC TO EXIT)

MODE : AWB / WAWB / INDOOR / OUTDOOR / MANUAL WAWB: Wide range auto white balance mode RGAIN : 0 ~ 255 BGAIN : 0 ~ 255

Use the AWB mode for normal use.

RGAIN / BGAIN modes are controllable only in MANUAL Mode.

Push the Joystick to the right or left to change.

Page 24 of the Philips Video Camera user manual — EXIT (ESC TO EXIT)
Page 24 · click to enlarge
Page 24
  • AE CONTROL

EDC-141E EDC-142E EDC-144E

AE SETUP

MODE : FULL AUTO SLOW SHUTTER : MANUAL IRIS : F2.4 GAIN : 0 DB BRIGHT : 14 SHUTTER : 1/60 EXIT (ESC TO EXIT)

MODE FULL AUTO / MANUAL / IRIS PRIO / SHUTTER PRIO / BRIGHT

SLOW SHUTTER AUTO / MANUAL – AUTO effects only FULL AUTO mode

IRIS : CLOSE / F22 / F19 / F16 / F14 / F11 / F9.6 / F8.0 / F6.8 / F5.6 / F4.8 / F4.0 / F3.4 / F2.8 / F2.4 / F2.0 / F1.6 / F1.4

GAIN0 / 2 / 4 / 6 ...... / 28 / -3dB
BRIGHT0, 1, 2, 3 ..... 29, 30, 31
SHUTTER1/1, 1/2, 1/4(3), 1/8(6). .. 1/4000, 1/6000, 1/10000

EXIT (ESC TO EXIT)

EDC-143E

AE SETUP

MODE : AE (DSS) SLOW SHUTTER : 1/4 IRIS : F2.4 GAIN : 0 DB WDR MODE : ON SHUTTER : AUTO EXIT (ESC TO EXIT)

MODE : SHUTTER PRIO / IRIS PRIO / AGC PRIO ) / AE (DARK) (IR Cut filter is automatically turned on and off more dark condition than AE (DARK) / AE (DSS) (automatic exposure without switching IR Cut filter)

SLOW SHUTTER1/60, 1/30, 1/15, 1/8, 1/4, 1/2 (1/50, 1/25, 1/12, 1/6, 1/3, 1/1.5)

IRIS : F1.6 / F2.2 / F3.2 / F4.4 / F6.4 / F8.8 / F12 / F17 / F24 / F34

GAIN0, 6, 12, 18, 24, 30dB

WDR MODE : Wide Dynamic Range Technology uses two shutter speeds in alternative video fields - high and normal - every 60th (or 50th) of a second and combines two fields into one progressive scan frame. It allows every detail to be captured accurately even if one portion of an image is brillantly bright while other portions are dark.

SHUTTER : 1/2, 1/4, 1/8, 1/15, 1/30, 1/60, 1/120, 1/180, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000, 1/30000 (1/1.5, 1/3, 1/6, 1/12, 1/25, 1/50, 1/100, 1/150, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000, 1/30000)

EXIT (ESC TO EXIT)

Page 25 of the Philips Video Camera user manual — EXIT (ESC TO EXIT)
Page 25 · click to enlarge
Page 25

EDC-142E1 EDC-142E2

AE SETUP

MODE : FULL AUTO SLOW SHUTTER : AUTO IRIS : F1.6 GAIN : 2DB BRIGHT : 30 SHUTTER : AUTO WDR MODE : ON EXIT (ESC TO EXIT)

MODEFULL AUTO / SHUTTER PRIO / IRIS PRIO / AGC / MANUAL
SLOW SHUTTERAUTO / OFF, ON (MANUAL, SHUTTER PRIO Mode)

IRIS : CLOSE / F1,6 / F2,0 / F2,8 / F4,0 / F5,6 / F8,0 / F11 / F16 / F22 / F32

GAINOFF, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20dB

BRIGHT : User can adjust brightness level (0 – +90). Level 30 is default.

SHUTTER : 1/1, 1/2, 1/3, 1/6, 1/10, 1/30, 1/60, 1/100, 1/125, 1/250, 1/500, 1/1.000, 1/2.000, 1/5.000, 1/10.000 (1/1, 1/2, 1/3, 1/6, 1/12, 1/25, 1/50, 1/100, 1/120, 1/250, 1/500, 1/1.000, 1/2.000, 1/4.000, 1/10.000)

WDR MODE : Wide Dynamic Range Technology uses two shutter speeds in alternative video fields - high and normal - every 60th (or 50th) of a second and combines two fields into one progressive scan frame. It allows every detail to be captured accurately even if one portion of an image is brillantly bright while other portions are dark.

EXIT (ESC TO EXIT)

  • LINE LOCK CONTROL

LINE LOCK SETUP

MODEINTERNAL PHASE : 125 EXIT (ESC TO EXIT)

MODE : INTERNAL / EXTERNAL. Adjusts phase of picture with other cameras in EXTERNAL mode.

PHASE : 0~255

EXIT (ESC TO EXIT)

  • NIGHT SHOT MENU (not at EDC-142E1 and EDC-142E)

The NIGHT SHOT option removes the IR cutoff filter of the camera and makes the camera sensitive to near infrared. This will set the BLACK & WHITE option to ON automatically.

NIGHT SHOT SETUP

MODEMANUAL LOCAL CONTROL : OFF EXIT (ESC TO EXIT)

MODE : MANUAL / AUTO / GLOBAL

AUTO: Camera goes in to B&W mode at low light.

GLOBALControlled by the keyboard

The operator can enable NIGHT SHOT for all dome cameras at the same time. If the NIGHT SHOT mode is set to GLOBAL, „9 9 9„ + Enter/Glbl will turn Off the NIGHT SHOT mode „8 8 8” + Enter/Glbl will turn On the NIGHT SHOT mode.

MANUALControlled by the local setting value

LOCAL CONTROL: ON/OFF will enable and disable Night Shot mode of an individual camera.

EXIT (ESC TO EXIT)

Page 26 of the Philips Video Camera user manual — FUNCTION ENABLE : ON / OFF
Page 26 · click to enlarge
Page 26

3.13 Dome Setup (Ninth Item of Main menu)

CONFIGURATION MENU

LANGUAGE SETUP HOME FUNCTION SETUP OSD DISPLAY VIEW ANGLE SETUP INITIALIZE DATA ORIGIN OFFSET DOME RESET SYSTEM INFORMATION EXIT (ESC TO EXIT)

  • LANGUAGE SETUP

LANGUAGE SETUP

LANGUAGEENGLISH SAVE AND EXIT (ESC TO EXIT)

LANGUAGE : Select the language you want. * This setup displays more than 3.0 of the ROM version.

  • HOME FUNCTION SETUP

After a dome control menu item has been selected, follow the directions below to set the function.

HOME FUNCTION SETUP

HOME FUNCTION : NONE FUNCTION NUMBER : --- WATING TIME : 120SEC FUNCTION ENABLE : OFF SAVE AND EXIT (ESC TO CANCEL)

HOME FUNCTIONNONE / PRESET / TOUR / PATTERN / AUTO SCAN
FUNCTION NUMBERxxx
WAITING TIME10~240 Seconds

FUNCTION ENABLE : ON / OFF

The Home function can be set so that the camera automatically goes to Preset, Tour, Pattern, Auto Scan after the keyboard controller has been idle for a amount of time. For example, if the Joystick controller is idle for 10 seconds, the camera goes to preset 1.

Follow these steps to program the Home position:

1. Press Menu to display the main menu on the monitor.
2. Select Home Function by pushing the Joystick to the right or to the left to scroll through the None, Tour, Pattern, Auto Scan and Preset functions.
3. Select Function Number by pushing the Joystick down, and push the Joystick to the right or to the left. The executable function number will scroll. Each function has maximum numbers. For example, you can have 240 Presets, 8 Tours, 4 Patterns and 8 Auto Scan options.
4. Select Function Time by pushing the Joystick down. Push the Joystick to the right or to the left to select from 10 to 240 seconds.
5. Select Function Enable by pushing the Joystick down. Turn the Home Enable ON or OFF by pushing the Joystick to the right or to the left.
Page 27 of the Philips Video Camera user manual — SAVE AND EXIT (ESC TO CANCEL)
Page 27 · click to enlarge
Page 27
  • OSD DISPLAY

OSD DISPLAY SETUP

CAMERA TITLEDOMEID VIEW DIRECTION : OFF DOME OSD DISPLAY : ON AREA DISPLAY : OFF

SAVE AND EXIT (ESC TO CANCEL)

CAMERA TITLE : 8 CHARACTER CAN BE SET

VIEW DIRECTION : ON / OFF

DOME OSD DISPLAY : ON / OFF

AREA DISPLAY : ON / OFF

  • VIEW DIRECTION

„ON” sets current direction as N(North) and the coordinate angle to 000. „OFF” hides the directional title. Every 90 degrees of clockwise rotation will change the title to E(East), S(South), W(West). If using the ON/OFF option frequently, it is recommended that you set „North” as a Preset. Recall the „North” Preset before enabling the directional title.

  • DOME OSD DISPLAY

All display or title will disappear when DOME OSD DISPLAY sets OFF

  • AREA DISPLAY

If this option is enabled, the nearest area title will be displayed when the camera is moving whether by manual operation, Auto Scan, or Pattern. Select ON or OFF by pushing the Joystick to the right or to the left. The Dome camera’s OSD option will override this function (Dome camera’s OSD must be enabled).

  • VIEW ANGLE SETUP

VIEW ANGLE SETUP

PANNING RANGE FLIPON TILT OVER ANGLE : W/O BUBBLE

SAVE AND EXIT (ESC TO CANCEL)

FLIP: ON / OFF

TILT OVER ANGLEw/o bubble, with bubble, ON
Page 28 of the Philips Video Camera user manual — INITIALIZE DATA
Page 28 · click to enlarge
Page 28
  • PANNING RANGE

When the dome camera is installed near wall, panning range could be programmed by user.

PANNING RANGE SETUP

RIGHT LIMIT : 000.0 LEFT LIMIT : 000.0 ENABLE SWAP : RIGHT/LEFT SAVE AND EXIT (ESC TO CANCEL)

  • FLIP

Allows the dome camera to automatically turn 180 degrees when the camera tilts to its lower position.

When camera reaches floor alone moving object, it will stop. Release the Joystick handle instantly and then pull down to run flip fucntion. The speed of following object will be same speed as previous.

  • TILT Over Angle

This option is used to set the limit of the horizontal view angle so that the trim ring or ceiling does not obstruct the horizontal image when zooming out (wide angle).

ON: In some installations it is desirable for the dome camera to be able to see the above horizon. When this option is chosen, the dome will tilt up over the horizon (about -10 degrees). When the lens is zoomed out, you can see the ceiling line. But when the lens is zoomed in the viewing angle is narrower, and the ceiling line disappears.

Without Bubble: The tilt range of the camera is limited to see the horizon so the picture shows part of the ceiling line.

With Bubble: The tilt range of the camera is limited to see below the horizon (10 degrees). Over Angle is not sufficient enough to avoid ceiling obstructions, please adjust Origin Offset of tilt angle as described below.

  • INITIALIZE DATA

INITIALIZE DATA

FACTORY DEFAULT ERASE PROGRAMMED DATA EXIT (ESC TO EXIT)

Erase all stored data from the Flash-ROM of the selected dome camera. You will be asked to enter Yes or No. If you intend to erase all data then press the Menu key, otherwise press the ESC key to exit without erasing. The erased data includes all stored data (titles, presets, and tours ) except origin offset.

The offset value is still valid after all data is erased. The offset value can be zero only with default set of Offset origin menu.

function in Keyboard Configuration utility.) Data from the selected dome camera can be stored in the keyboard controller temporarily. If you want to save the data of all installed dome cameras, you need a special I/O interface and software for PC.

  • ORIGIN OFFSET

This feature is useful to align a replaced dome camera to the exactly same position as the previously installed dome camera.

Dome camera’s origin set and all data initialize option do not override offset values. Only the default set option in this menu will set the offset value to zero. This can be used to avoid ceiling obstructions.

Page 29 of the Philips Video Camera user manual — 4. Troubleshooting
Page 29 · click to enlarge
Page 29
  • DOME RESET

This feature is used to re-calibrate the orientation of a selected dome camera. Origin offset value is not affected by this function. (Offset is still valid after origin set)

  • SYSTEM INFORMATION

SYSTEM INFORMATION

CAMERA TYPE : XXXXXXX H/W VERSION : V2.1 ROM VERSION : V2.11 PROTOCOL : F2E BAUDRATE : 9600BPS EXIT (ESC TO EXIT)

A Dome camera’s Setup menu provides essential information about the dome camera when service is required. When you view this screen, you can determine the camera type, ROM version. The information on this screen cannot be modified.

4. Troubleshooting

If problems occur, verify the installation of the camera with the instructions in this manual and with other operating equipment. Isolate the problem to the specific piece of equipment in the system and refer to the equipment manual for further information.

Verify that power is connected to all pieces of equipment in the system. Verify that the power switches are in the ON position. Check the video connections (see Figures 4).

Check that the BNC connectors are inserted properly. Check the voltage level of the dome camera. Check that 8 pin cable is connected to the Keyboard. Check 8 pin cable for Keyboard is proprietary. (Cable for video is shielded.) Check termination of Video.

Reset the cameras using the Dome configuration menus. Check that the dome cameras are inserted properly in the base. Check the voltage level of the dome camera. Camera number does not match the multiplexer number. Check the camera ID and insert the BNC cable into the proper input of the multiplexer. Picture is torn when switching Check Line Lock setting and adjust phase of L/L (see page 25).

Dome cameras lose their positions.

Problem Possible Solution · No video · Poor video quality

Page 30 of the Philips Video Camera user manual — 5. Glossary
Page 30 · click to enlarge
Page 30

5. Glossary

Alarm Actions The assigned responses for the dome camera when inputs change from normal to abnormal states. The dome may run a Preset, Pattern, or have no assigned action for each of the four dome inputs. The dome may also send alarm states to the host controller for processing. See also Input and Normal Input State. Areas Programmed start and end points of the dome’s field of view around its pan axis. Each area is a part of a circular viewing area that extends around the dome. The areas can be different sizes. Up to 16 areas can be programmed for the dome. Automatic Gain Control (AGC)

Allows for the amplification of the video signal in scenes with minimal ambient light. Many low-light scenes result in picture noise. As gain is increased, the picture noise is also amplified. When AGC is enabled, the value of the gain setting is based on feedback from the camera. When AGC is disabled, the camera uses the value set for the manual gain setting. The trade-off between picture level and noise may be adjusted when AGC is disabled. On-screen Menu The text overlay menu system used for setting dome features. The utility is accessed using a keystroke combination. The utility provides settings for camera functions, zoom, alarms, text display, and password protection. Flip Allows the dome to automatically turn 180 degrees when the camera tilts to its lower limit and stays in that position for a brief delay. When the dome flips (rotates), the camera starts moving upward as long as the tilt control is kept in the down position. Once the Joystick handle is released to neutral position, the tilt control returns to its normal operational mode. The flip feature is useful when you need to track someone who walks directly beneath of the dome and continues on the other side. Home Position The default position to which the dome camera returns after an assigned period of inactivity passes. The default position may be a Preset, Tour, Pattern, or No Action. Input Alarm A connection point on the dome camera that enables the system to monitor Input Devices. There are four inputs available for the dome camera. Input Devices External devices that provide information about the condition of system components that connect to the inputs on the dome camera. Typical input devices include door contacts, motion detectors and smoke detectors. IR Mode A feature of the camera that permits manual or automatic switching between colour and IR (black-and-white) operation. When IR mode is active, clearer images may be obtained under low-light conditions. Line Lock Allows you to phase lock the video with the AC power line. When line lock is enabled, it prevents vertical video rolling when switching multiple cameras to a single monitor. If text appears slightly tinted on colour monitors, disabling the line lock may prevent this problem. Name Information Relates to the display the dome name, the area where the dome is pointing, the name of the preset or pattern that is running, and alarm names. The display of each type of name setting can be enabled or disabled. When the display of camera or area title (name) is enabled, the information appears on the screen continuously. Preset, tour and pattern titles (names) appear only while they are active. Normal Input State Describes the expected state of a device connected to one of eight dome camera’s inputs. The normal state may be open or closed. When a device is not in its normal input state, an alarm is issued. North Position User-definable setting that may correspond to magnetic north or some well-known landmark. Used to approximate the camera dome's pointing direction when Direction Indicators are enabled. Low Shutter Setting used to improve the quality of video obtained in extreme low-light situations. When the Low Shutter setting is enabled, low- light information is collected over multiple fields based on the Shutter Limit setting. As a result, video may appear blurred or choppy in extreme low-light situations. This setting does not effect camera operation in normal lighting situations. See also Automatic Gain Control (AGC). Pattern A series of pan, tilt, zoom and focus movements from a single programmable dome. Up to 8 patterns may be programmed for the dome camera. Preset Programmed video scene, based on a specific pan, tilt, zoom, and focus settings. Up to 240 presets may be programmed for the dome camera. Privacy Zones This function maskes areas of the dome camera's viewing area. These masks prevent operators of the surveillance system from viewing these designated zones. The Privacy Zones move in relation to the dome camera’s pan/tilt position. In addition, the apparent size of the Privacy Zone adjusts automatically as the lens zooms in or out. Up to eight Privacy Zones may be established for a dome camera. Shutter Limit Setting used to define the maximum exposure time for the Open Shutter setting. The values for the setting range from 1/2 to 1/60. The default setting is 1/4. Vector Scan Move from start point to end point including tilt and zoom simultaneously and linearly. WDR Wide Dynamic Range Technology uses two shutter speeds in alternative video fields-high and normal- every 60th (or 50th) of a second and combines two fields into one progressive scan frame. It allows every detail to be captured accurately even if one portion of an image is brillantly. Whether at the high shutter speed or normal shutter speed, the progressive scan CCD provides a horizontal resolution of 470 lines. As a result, combined fields yield a frame of high-quality images. White balance Adjustments in the colour hue (red and blue) gains for a camera so that true white appears white in the image. It is normally com pensated for by the automatic gain control. In some lighting conditions, you may need to manually adjust the red and blue settings for optimal viewing. When Automatic White Balance is enabled, the camera measures the image and automatically adjusts the red and blue settings to balance white. When Automatic White Balance is disabled, the camera uses the values set for the red and blue settings to balance white.

Page 31 of the Philips Video Camera user manual — 6. Short Cut Key
Page 31 · click to enlarge
Page 31

6. Short Cut Key

Short Cut Key Function PRST Pop up preset setup menu TOUR Pop up guard Tour setup menu PTRN Pop up Pattern setup menu SCAN Pop up Auto Scan setup menu NO.+ PGM + PRST Store the current view at the selected number NO.+ PGM + TOUR Pop up tour setup menu at the selected number NO.+ PGM + SCAN Pop up auto scan setup menu at the selected number 1 ~ 4 + ON Turn On Relay 1 ~ 4 + OFF Turn Off Relay 10 + ON Night Shot on 10 + OFF Night Shot off 11 + ON BLC on 11 + OFF BLC off 12 + ON Digital Zoom on (According to digital zoom setting) 12 + OFF Digital Zoom off 13 + ON Dome OSD on 13 + OFF Dome OSD off 14 + ON Dome Area Title Display on 14 + OFF Dome Area Title Display off 15 + ON View Direction on 15 + OFF View Direction off 100 + ON Shutter speed auto 101 + ON Shutter speed 1/4 (PAL 1/3) sec 102 + ON Shutter speed 1/2 sec 103 + ON Shutter speed 1 sec 104 + ON WDR on 104 + OFF WDR off

Some function may not operate according to the model.

Page 32 of the Philips Video Camera user manual — 7. Specifications
Page 32 · click to enlarge
Page 32

7. Specifications

Model EDC-142E EDC-141E EDC-143E EDC-142E1 EDC-144E EDC-142E2 EDP 74081 74086 74091 74093 74100 74117 Imager 1/4” 752 (H) x 582 (V) pixels (Sony ExView Interline Transfer CCD) Sensitivity 1.0Lux at F1.4 (0.75Lux at F1.2)

0.7Lux at F1.4 (0.5Lux at F1.2);

3.0Lux at F1.6 (1.7Lux at F1.2); 0.2Lux at

1.0Lux at F1.4; 0.02Lux at 1sec. shutter speed

0.35Lux at F1.6 (0.2Lux at F1.2); 0.2Lux at

1.0Lux at F1.4; 0.02Lux at 1sec. shutter speed

0.05Lux at 1/3sec. shutter speed; 0.01Lux

1/3sec. shutter speed; 0.02Lux

1/3sec. shutter speed (F1.6);

at 1/3sec. shutter speed and IR cut filter

at 1/3sec. shutter speed and IR cut filter

0.02Lux at 1/3sec. shutter speed (colour)

0.01Lux at 1/3sec. shutter speed (b&w)

Horizontal resolution 480 TV lines Adresses – Up to 999 Dome ID’s Dynamic range (WDR) – 60db – Speed range at manual control (pan) 0.1° to 90°/sec., Turbo: 360°/sec.

0.5° to 90°/sec., Turbo380°/sec. (Proportional to the zoom position)

Speed range at manual control (tilt) 0.1° to 90°/sec. (Proportional

0.5° to 90°/sec. (Proportional to the zoom position)

Preset speed Up to 380°/sec. pan Rotation range 360° (endless) Vertical tilt range -10° to +90° -4° ~ +90° Preset positioning 240 presets with 16-character labels each. 0.75sec. max. preset recall time Backlash 0.2° Patterns 4 patterns: 1x up to 240sec., or 3x up to 240sec. in total Tours Up to 8 User programmable guard tours with vector scan. Consisting of 42 presets and other functions with

individual dwell time (3 to 99sec.). Selectable fast or slow vector scan Autoscan 8 User programmable auto scans with selectable fast or slow vector scan, 9 selectable speeds Proportional pan and tilt – Continually decreases pan and tilt speeds in proportion to depth of zoom Auto flip function Rotates dome 180° at bottom of tilt travel Programmable park position Included Window blanking – 8 dynamic window blanking zones with user-defined four-sided shapes

8 areas 8 dynamic window blanking

and up to 16-character labels each

four-sided shapes and up to 16-character

Zones – 16 each with programmable text labels

16 each with programmable

in size) can be labelled with up to 16 characters

in size) can be labelled with up to 16 characters

each or set to

each or set to

video In/outdoor use Indoor/outdoor camera preferences IR cut filter – Motorized, switchable filter. Automatic function depend on the

– Motorized, switchable filter. Automatic function depend on the

amount of light. In removed filter position, the colour signal will be

amount of light. In removed filter position, the colour signal will be

switched OFF. Digital signal processing (DSP) Yes (DSP-3R) Signal-to-noise ratio 50dB Automatic gain control (AGC) Automatic (ON/OFF switchable) Shutter speed (AES/MES) Automatic/ manual: 1/50 to

switched OFF.

Automatic/ manual1/1 to
Automatic/ manual1/1.5 to
Automatic/ manual1/1 to
Automatic/ manual1/3 to
Automatic/ manual1/1 to

1/10,000 sec.

1/10,000 sec.

1/30,000sec.

1/10,000sec.

1/10,000sec.

1/10,000sec.

Show 16 more labels / short text on this page
removed · removed · (Proportional · to the zoom · position) · to the zoom · position) · 8 areas · zones with user-defined · labels each · 16 areas (programmable · 16 areas (programmable · text labels · output blank · output blank · video
Page 33 of the Philips Video Camera user manual — 3.13 Dome Setup (Ninth Item of Main menu)
Page 33 · click to enlarge
Page 33

Model EDC-142E EDC-141E EDC-143E EDC-142E1 EDC-144E EDC-142E2 EDP 74081 74086 74091 74093 74100 74117 Shutter modes – High and Low Speed shutter – High and Low Speed shutter

Synchronization Internal/AC line lock, phase adjustment via remote control White balance Modes: Manual, Automatic, Indoor, Outdoor, ATW Video output 1Vp-p, CVBS, 75ohms, BNC Zoom range F1.4-3.0/4.1-73.8mm (18x optical,

F1.4/3.8- 83.6mm (22x optical, 12x digital zoom) Horizontal angle of view 48° (Wide); 2.7° (Tele end) 54° (Wide); 2.5° (Tele end)

12x digital zoom) F1.6/ 3.6~82.8mm (23 optical, 10x

F1.4/3.8- 83.6mm (22x optical, 12x digital zoom)

F1.6~F80/3.5 ~ 91mm (26x

optical, 12x digital zoom)

54.2° (Wide); 2.2° (Tele end) 52° (Wide); 2.4° (Tele end) Iris control Automatic (with manual override) Focus control Automatic with manual override Minimum object distance (MOD) 0.3m Menu driven set-up ON/OFF switchable Text display 16-character labels Menu languages English English, German, French, Spanish, Portuguese, Italian, Polish Alarm processing – Programmable alarm action with selectable priority levels Alarm inputs – 8, selectable between NO and NC Bubble 4.9” (125mm), clear acrylic plastic Control interfaces RS-422/RS-485,

52° (Wide); 2.4° (Tele end)

RS-422/RS-485, 9600Baud, 999 camera ID adresses selectable. Besides the keyboard control

9600Baud, 999 camera ID adres

via the eneo EDC-KBD(M) series, the control via matrix switchers and keyboards from Pelco

(D+P protocol), Ernitec, Philips G3, Sensormatic RS-422, (back channel via RS-422 is not

ses selectable. Besides the key board control via

activated), Vicon and Dynacolor is available.

the eneo EDC- KBD(M) series,

the control via matrix switchers

and keyboards from Pelco (D+P protocol), Ernitec,

etc. is available.

Keyboard control Direct mode control with Eneo EDC-KBD(M) keyboard series, or in conjunction with the eneo Triplex Multiplexer

series VBMT/VCMT-8000 and DVR series DLR(2) and DXR Auxiliary outputs – 4 relays with NO/NC contact, 24VDC/1A resistive Remote control Camera remote settings via keyboard Operation protection Available Backup Non-volatile back box memory stores all camera and site-specific dome settings Supply voltage 18 to 30VAC (24VAC nominal), 50/60Hz Power consumption Approx. 20watts Temperature range 0°C to +50°C Protection rating IP40 Housing Black plastic for indoor drop-ceiling mount Dimensions See drawing Weight 1.3kg 1.5kg

digital zoom)

Page 34 of the Philips Video Camera user manual — 8. Dimensional Drawings
Page 34 · click to enlarge
Page 34

EDP No. Description 74088 System Keyboard with 3-axis Joystick, 12VDC/230VAC 74092 System Keyboard with Joystick, 5” Monitor, 12VDC/230VAC 75201 Matrix, Multiplexer and Telemetry Keyboard with Joystick, RS-485 Control 74057 Flush Mount Dome Housing, Smoked Bubble, 4.9” 74078 Pendant Mount Outdoor Dome Housing, Tinted Bubble 6.8”, 24VAC 74077 Pendant Mount Indoor Dome Housing, Clear Bubble 6.8”, 24VAC 74076 Pendant Mount Outdoor Dome Housing, Clear Bubble 6.8”, 24VAC 74075 Pendant Mount Indoor Dome Housing, Tinted Bubble 6.8”, 24VAC 74082 Pendant Mount Indoor Dome Housing, Clear Bubble 6.8”, 230VAC 74083 Pendant Mount Indoor Dome Housing, Tinted Bubble 6.8”, 230VAC 74084 Pendant Mount Outdoor Dome Housing, Clear Bubble 6.8”, 230VAC 74085 Pendant Mount Outdoor Dome Housing, Tinted Bubble 6.8”, 230VAC 74089 Converter RS-232/RS-485, Repeater RS-485 74095 Protocol Converter BiPhase to RS-422, 12VDC 70449 Voltage Supply Unit 230V/24VAC-5A, IP66 74094 Coax Telemetry Board for VPT-41/42, EDC/EDMC series, assembled 70457 Camera Connection Box, 230VAC Input, 24VAC-100W, 12VDC-1A Output

8. Dimensional Drawings

R2.3

R5

Dimensionsmm

eneo® is a registered trademark of Videor Technical E. Hartig GmbH Exclusive distribution through specialised trade channels only.

VIDEOR TECHNICAL E. Hartig GmbH Carl-Zeiss-Straße 8 · 63322 Rödermark/Germany Tel. +49 (0) 6074 / 888-0 · Fax +49 (0) 6074 / 888-100

Technical changes reserved.

www.videortechnical.com

© Copyright by VIDEOR TECHNICAL 02/2007

Accessories

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
No videoVerify that power is connected to all pieces of equipment in the system. Verify that the power switches are in the ON position. Check the video connections (see Figures 4). p.29
Poor video qualityCheck that the BNC connectors are inserted properly. Check the voltage level of the dome camera. Check that 8 pin cable is connected to the Keyboard. Check 8 pin cable for Keyboard is proprietary. (Cable for video is shielded.) Check termination of Video. p.29
Dome cameras lose their positions.Reset the cameras using the Dome configuration menus. Check that the dome cameras are inserted properly in the base. Check the voltage level of the dome camera. p.29
Camera number does not match the multiplexer number.Check the camera ID and insert the BNC cable into the proper input of the multiplexer. p.29
Picture is torn when switchingCheck Line Lock setting and adjust phase of L/L (see page 25). p.29

Ask about the Philips Video Camera

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Philips Video Camera

Be the first to ask — other owners or our team will answer.

Original document

Philips Video Camera manual PDF

34 pages·2.6 MB·Digital Camera·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…