EN
Philips logo
Official user manual

Philips UDA1325

52 pages·246 KB·Computer Drive·PDF·ENDEFRITNLJA
Philips UDA1325
Table of Contents 76 sections FEATURES · General · Audio playback channel · Audio recording channel · … ShowHide
FEATURESp.2Generalp.2Audio playback channelp.2Audio recording channelp.2USB endpointsp.2Document referencesp.2APPLICATIONSp.3GENERAL DESCRIPTIONp.3ORDERING INFORMATIONp.3QUICK REFERENCE DATAp.4BLOCK DIAGRAMp.5PINNINGp.6FUNCTIONAL DESCRIPTIONp.9The Universal Serial Bus (USB)p.9The analog front-endp.9The USB processorp.9Bit clock recoveryp.9Philips Serial Interface Engine (PSIE)p.9Memory Management Unit (MMU) and integrated RAMp.10Audio Sample Redistribution (ASR)p.10The 80C51 microcontrollerp.10The Analog-to-Digital Interface (ADIF)p.10Programmable Gain Amplifier circuit (PGA)p.10The Analog-to-Digital Converter (ADC)p.10The Decimation Filter (DF)p.10The clock source of the analog-to-digital interfacep.11The Asynchronous Digital-to-Analog Converter (ADAC)p.12The Sample Frequency Generator (SFG)p.12First-In First-Out (FIFO) registersp.12The sound processing DSPp.12The upsampling filters and variable hold functionp.12The noise shaperp.12The Filter Stream DAC (FSDAC)p.12USB ENDPOINT DESCRIPTIONp.13CONTROLLING THE PLAYBACK FEATURESp.13Controlling the playback features of the ADACp.13Soft mute controlp.16Volume controlp.17Treble controlp.18Bass controlp.18De-emphasisp.19Filter characteristics playback channelp.20DSP extension port for enhanced playback audio processingp.21PORT DEFINITION 80C51p.23Port 1p.23Port 3p.23MEMORY AND REGISTER SPACE 80C51p.24Overview registersp.24Interruptsp.24Internal registersp.25START-UP BEHAVIOUR AND POWER MANAGEMENTp.28Start-up of the UDA1325p.28Power Managementp.28COMMAND SUMMARYp.30COMMAND DESCRIPTIONSp.31Command procedurep.31Initialization commandsp.31Data flow commandsp.32General commandsp.35I 2 C MASTER/SLAVE INTERFACEp.35Characteristics of the I 2 C-busp.35Programmer’s viewp.35S1CON registerp.35LIMITING VALUESp.37THERMAL CHARACTERISTICSp.37RECOMMENDED OPERATING CONDITIONSp.37DC CHARACTERISTICSp.38AC CHARACTERISTICSp.40APPLICATION INFORMATIONp.44PACKAGE OUTLINESp.47SOT270-1p.47SOT319-2p.48SOLDERINGp.49DEFINITIONSp.51LIFE SUPPORT APPLICATIONSp.51PURCHASE OF PHILIPS I 2 C COMPONENTSp.51
Page 1 of the Philips UDA1325 user manual — INTEGRATED CIRCUITS
Page 1 · click to enlarge
Page 1

INTEGRATED CIRCUITS

DATA SHEET

UDA1325 Universal Serial Bus (USB) CODEC

Preliminary specification File under Integrated Circuits, IC01

Page 2 of the Philips UDA1325 user manual — FEATURES
Page 2 · click to enlarge
Page 2

FEATURES

  • One isochronous input endpoint
  • Supports multiple audio data formats (8, 16 and 24 bits)
  • High Quality USB-compliant Audio/HID device
  • Supports 12 Mbits/s serial data transmission
  • Twelve selectable sample rates (4, 8, 16 or 32 kHz; 5.5125, 11.025, 22.05 or 44.1 kHz; 6, 12, 24 or 48 kHz) via analog PLL (APLL).
  • Fully USB Plug and Play operation
  • Supports ‘Bus-powered’ and ‘Self-powered’ operation
  • Selectable sample rate between 5 to 55 kHz via a second oscillator (optional)
  • 3.3 V power supply
  • Low power consumption with optional efficient power control
  • One slave 20-bit I 2 S digital stereo recording input, I 2 S and LSB justified serial formats
  • On-chip clock oscillator, only an external crystal is required.
  • Programmable Gain Amplifier for left and right channel
  • Low total harmonic distortion (typical 85 dB)
  • High signal-to-noise ratio (typical 90 dB)
  • One stereo Line/Microphone input.
  • One isochronous output endpoint
  • Supports multiple audio data formats (8, 16 and 24 bits)
  • Adaptive sample frequency support from 5 to 55 kHz
  • 2 control endpoints
  • One master 20-bit I 2 S digital stereo playback output, I 2 S and LSB justified serial formats
  • 2 interrupt endpoints
  • 1 isochronous data sink endpoint
  • One slave 20-bit I 2 S digital stereo playback input, I 2 S and LSB justified serial formats
  • 1 isochronous data source endpoint.
  • Selectable volume control for left and right channel
  • Soft mute control
  • “USB Specification”
  • Digital bass and treble tone control
  • “USB Device Class Definition for Audio Devices”
  • Selectable on-chip digital de-emphasis
  • “Device Class Definition for Human Interface Devices (HID)”
  • Low total harmonic distortion (typical 90 dB)
  • High signal-to-noise ratio (typical 95 dB)
  • “USB HID Usage Table”.
  • One stereo Line output.
  • “USB Common Class Specification”.
Show 5 more labels / short text on this page
Audio recording channel · General · Audio playback channel · USB endpoints · Document references
Page 3 of the Philips UDA1325 user manual — ORDERING INFORMATION
Page 3 · click to enlarge
Page 3

APPLICATIONS

All I2S inputs and I2S outputs support standard I2S-bus format and the LSB justified serial data format with word lengths of 16, 18 and 20 bits.

  • USB monitors
  • USB speakers

Via the digital I/O module with its I2S input and output, an external DSP can be used for adding extra sound processing features for the audio playback channel.

  • USB microphones
  • USB headsets
  • USB telephone/answering machines

The microcontroller is responsible for handling the high-level USB protocols, translating the incoming control requests and managing the user interface via general purpose pins and an I2C-bus.

  • USB links in consumer audio devices.

GENERAL DESCRIPTION

The ADAC enables the wide and continuous range of playback sampling frequencies. By means of a Sample Frequency Generator (SFG), the ADAC is able to reconstruct the average sample frequency from the incoming audio samples. The ADAC also performs the playback sound processing. The ADAC consists of a FIFO, an unique audio feature processing DSP, the SFG, digital filters, a variable hold register, a Noise Shaper (NS) and a Filter Stream DAC (FSDAC) with line output drivers. The audio information is applied to the ADAC via the USB processor or via the digital I2S input of the digital I/O module.

The UDA1325 is a single chip stereo USB codec incorporating bitstream converters designed for implementation in USB-compliant audio peripherals and multimedia audio applications. It contains a USB interface, an embedded microcontroller, an Analog-to-Digital Interface (ADIF) and an Asynchronous Digital-to-Analog Converter (ADAC).

The USB interface consists of an analog front-end and a USB processor. The analog front-end transforms the differential USB data into a digital data stream. The USB processor buffers the incoming and outgoing data from the analog front-end and handles all low-level USB protocols. The USB processor selects the relevant data from the universal serial bus, performs an extensive error detection and separates control information and audio information. The control information is made accessible to the microcontroller. At playback, the audio information becomes available at the digital I2S output of the digital I/O module or is fed directly to the ADAC. At recording, the audio information is delivered by the ADIF or by the digital I2S input of the I2S-bus interface.

The ADIF consists of an Programmable Gain Amplifier (PGA), an Analog-to-Digital Converter (ADC) and a Decimator Filter (DF). An Analog Phase Lock Loop (APLL) or oscillator is used for creating the clock signal of the ADIF. The clock frequency for the ADIF can be controlled via the microcontroller. Several clock frequencies are possible for sampling the analog input signal at different sampling rates.

The wide dynamic range of the bitstream conversion technique used in the UDA1325 for both the playback and recording channel guarantees a high audio sound quality.

ORDERING INFORMATION

TYPE NUMBERPACKAGE NAMEDESCRIPTIONVERSION UDA1325PSSDIP42plastic shrink dual in-line package; 42 leads (600 mil)SOT270-1 UDA1325HQFP64plastic quad flat package; 64 leads (lead length 1.95 mm); body 14 × 20 × 2.8 mmSOT319-2
Page 4 of the Philips UDA1325 user manual — QUICK REFERENCE DATA
Page 4 · click to enlarge
Page 4

QUICK REFERENCE DATA

SYMBOLPARAMETERCONDITIONSMIN.TYP.MAX.UNIT Supplies V DDEsupply voltage periphery4.755.05.25V V DDIsupply voltage core3.03.33.6V I DD(tot)total supply current−60tbfmA I DD(tot)(ps)total supply current in power-saving modenote 1−360−µA Dynamic performance DAC (THD + N)/Stotal harmonic distortion plus noise-to-signal ratiof = 44.1 kHz; R = 5 kΩ s L f = 1 kHz (0 dB) i f = 1 kHz (−60 dB) i−−90 0.0032 −30 3.2−80 0.01 −20 10dB % dB % S/Nsignal-to-noise ratio at bipolar zeroA-weighted at code 0000H9095−dBA V o(FS)(rms)full-scale output voltage (RMS value)V = 3.3 V DD−0.66−V Dynamic performance PGA and ADC (THD + N)/Stotal harmonic distortion plus noise-to-signal ratiof = 44.1 kHz; s PGA gain = 0 dB f = 1 kHz; (0 dB); i V = 1.0 V (RMS) i f = 1 kHz (−60 dB) i−−85 0.0056 −30 3.2−80 0.01 −20 10.0dB % dB % S/Nsignal-to-noise ratioV = 0.0 V i9095−dBA General characteristics f i(s)audio input sample frequency5−55kHz T amboperating ambient temperature02570°C
1. Exclusive the IDDE current which depends on the components connected to the I/O pins.
Page 5 of the Philips UDA1325 user manual — BLOCK DIAGRAM
Page 5 · click to enlarge
Page 5

BLOCK DIAGRAM

handbook, full pagewidthCLKD+D−P0.7 to P0.0P2.0 to P2.7 27 8 (9) 6 (8) 7, 5, 3, 64, 14, 16, 18, 20, 62, 60, 58, 56 22, 23, 29, 30 (10) 9 VDDI VSSX 24 (19) ( (1 11 2) 1 10 V VS SS SI ) 1 E XTAL1b 25 (20) ANALOG FRONT-END OSC (13) 12 VDDE X VT V DA D DL D A2 Xb 2 2 56 8 ( ( (2 2 31 2 9) ) 48 MHz TIMING ( (2 23 9) 3 32 VVV DSD DD AO ( 2 4 ) 3 3 S O 3 2 ) ) 8 1 XTAL2a 53 (40) XTAL1a 54 (41) OSC ANALOG USB-PROCESSOR (30) 39 VSSA1 VSSA3 55 (42) ADC PLL ( (3 33 5) 4 42 VV SD SD AA 22 ) 4 GP2/DO 63 (4) GP3/WSO 1 (5) GP4/BCKO 2 (6) GP1/DI 13 (14) DIGITAL I/O (17) 19 SCL GP0/BCKI 17 (16) MICRO- (18) 21 SDA GP5/WSI 15 (15) CONTROLLER PSEN 31 MUX FIFO DA 57 (1) SAMPLE AUDIO FEATURE WS 59 (2) I2S-BUS FREQUENCY PROCESSING DSP BCK 61 (3) INTERFACE GENERATOR DECIMATOR FILTER UPSAMPLE FILTERS (7) 4 SHTCB EA 48 TEST (26) 35 TC CONTROL ALE 50 BLOCK (27) 36 RTCB VARIABLE HOLD REGISTER VINL 43 (34) PGA LEFT 3rd-ORDER NOISE SHAPER Σ∆ ADC UDA1325 L DE AF CT − (25) 34 VOUTL VINR 47 (36) RIGHT + PGA Σ∆ ADC + (28) 37 VOUTR VRN 49 (37) REFERENCE VOLTAGE R DIG AH CT − VRP 51 (38) 45, 46 41 (32) 40 (31) n.c. Vref(AD) Vref(DA) MGM108 The pin numbers given in parenthesis refer to the SDIP42 version. Fig.1 Block diagram (QFP64 package).8 (9)
Philips UDA1325 — BLOCK DIAGRAM diagram (page 5)
Fig. 1
OSC 48 MHzTIMING OSC ADCANALOG PLL
Page 6 of the Philips UDA1325 user manual — PINNING
Page 6 · click to enlarge
Page 6

PINNING

SYMBOLPIN QFP64PIN SDIP42I/ODESCRIPTION GP3/WSO15I/Ogeneral purpose pin 3 or word select output GP4/BCKO26I/Ogeneral purpose pin 4 or bit clock output P0.53−I/OPort 0.5 of the microcontroller SHTCB47Ishift clock of the test control block (active HIGH) P0.65−I/OPort 0.6 of the microcontroller D−68I/Onegative data line of the differential data bus, conforms to the USB standard P0.77−I/OPort 0.7 of the microcontroller D+89I/Opositive data line of the differential data bus, conforms to the USB standard V DDI910−digital supply voltage for core V SSI1011−digital ground for core V SSE1112−digital ground for I/O pads V DDE1213−digital supply voltage for I/O pads GP1/DI1314I/Ogeneral purpose pin 1 or data input P2.014−I/OPort 2.0 of the microcontroller GP5/WSI1515I/Ogeneral purpose pin 5 or word select input P2.116−I/OPort 2.1 of the microcontroller GP0/BCKI1716I/Ogeneral purpose pin 0 or bit clock input P2.218−I/OPort 2.2 of the microcontroller SCL1917I/Oserial clock line I2C-bus P2.320−I/OPort 2.3 of the microcontroller SDA2118I/Oserial data line I2C-bus P2.422−I/OPort 2.4 of the microcontroller P2.523−I/OPort 2.5 of the microcontroller V SSX2419−crystal oscillator ground (48 MHz) XTAL1b2520Icrystal input (analog; 48 MHz) XTAL2b2621Ocrystal output (analog; 48 MHz) CLK27−O48 MHz clock output signal V DDX2822−supply crystal oscillator (48 MHz) P2.629−I/OPort 2.6 of the microcontroller P2.730−I/OPort 2.7 of the microcontroller PSEN31−I/Oprogram store enable (active LOW) V DDO3223−supply voltage for operational amplifier V SSO3324−operational amplifier ground VOUTL3425Ovoltage output left channel TC3526Itest control input (active HIGH) RTCB3627Iasynchronous reset input of the test control block (active HIGH) VOUTR3728Ovoltage output right channel
Page 7 of the Philips UDA1325 user manual — PINNING
Page 7 · click to enlarge
Page 7
SYMBOLPIN QFP64PIN SDIP42I/ODESCRIPTION V DDA13829−analog supply voltage 1 V SSA13930−analog ground 1 V ref(DA)4031Oreference voltage output DAC V ref(AD)4132Oreference voltage output ADC V DDA24233−analog supply voltage 2 VINL4334Iinput signal left channel PGA V SSA24435−analog ground 2 n.c.45−−not connected n.c.46−−not connected VINR4736Iinput signal right channel PGA EA48−−external access (active LOW) VRN4937Inegative reference input voltage ADC ALE50−−address latch enable (active HIGH) VRP5138Ipositive reference input voltage ADC V DDA35239−supply voltage for crystal oscillator and analog PLL XTAL2a5340Ocrystal output (analog; ADC) XTAL1a5441Icrystal input (analog; ADC) V SSA35542−crystal oscillator and analog PLL ground P0.056−I/OPort 0.0 of the microcontroller DA571Idata Input (digital) P0.158−I/OPort 0.1 of the microcontroller WS592Iword select Input (digital) P0.260−I/OPort 0.2 of the microcontroller BCK613Ibit clock Input (digital) P0.362−I/OPort 0.3 of the microcontroller GP2/DO634I/Ogeneral purpose pin 2 or data output P0.464−I/OPort 0.4 of the microcontroller
Page 8 of the Philips UDA1325 user manual — D +
Page 8 · click to enlarge
Page 8

GP2/DO

VSSA3

VDDA3

P0.4

P0.3

BCK

P0.2

WS

P0.1

DA

P0.0

GP3/WSO

VRP

GP4/BCKO

ALE

P0.5

VRN

SHTCB

EA

P0.6

VINR

D −

n.c.

P0.7

n.c.

D +

VSSA2

VDDI

VINL

VSSI

UDA1325H

VDDA2

VSSE

VDDE

GP1/DI

VSSA1

P2.0

VDDA1

GP5/WSI

VOUTR

P2.1

RTCB

GP0/BCKI

TC

P2.2

VOUTL

SCL

VSSO

P2.3

SDA

P2.4

P2.5

VSSX

CLK

VDDX

P2.6

P2.7

PSEN

VDDO

MGL349

Fig.2 Pin configuration (QFP64 package).

Show 7 more labels / short text on this page
handbook, full pagewidth · XTAL1a · XTAL2a · Vref(AD) · Vref(DA) · XTAL1b · XTAL2b
Page 9 of the Philips UDA1325 user manual — FUNCTIONAL DESCRIPTION
Page 9 · click to enlarge
Page 9

FUNCTIONAL DESCRIPTION

handbook, halfpage DA 142 VSSA3 WS 2 41 XTAL1a BCK 3 40 XTAL2a GP2/DO 4 39 VDDA3 GP3/WSO 5 38 VRP GP4/BCKO 6 37 VRN SHTCB 7 36 VINR D− 8 35 VSSA2 D+ 9 34 VINL VDDI 10 33 VDDA2 VSSI 11 UDA1325 32 Vref(AD) VSSE 12 31 Vref(DA) VDDE 13 30 VSSA1 GP1/DI 14 29 VDDA1 GP5/WSI 15 28 VOUTR GP0/BCKI 16 27 RTCB SCL 17 26 TC SDA 18 25 VOUTL VSSX 19 24 VSSO XTAL1b 20 23 VDDO XTAL2b 21 22 VDDX MGM106 Fig.3 Pin configuration (SDIP42 package).UDA1325

The Universal Serial Bus (USB)

Data and power is transferred via the USB over a 4-wire cable. The signalling occurs over two wires and point-to-point segments. The signals on each segment are differentially driven into a cable of 90 Ω intrinsic impedance. The differential receiver features input sensitivity of at least 200 mV and sufficient common mode rejection.

The analog front-end is an on-chip generic USB transceiver. It is designed to allow voltage levels up to VDD from standard or programmable logic to interface with the physical layer of the USB. It is capable of receiving and transmitting serial data at full speed (12 Mbits/s).

The USB processor forms the interface between the analog front-end, the ADIF, the ADAC and the microcontroller. The USB processor consists of:

  • A bit clock recovery circuit
  • The Philips Serial Interface Engine (PSIE)
  • The Memory Management Unit (MMU)
  • The Audio Sample Redistribution (ASR) module.

The bit clock recovery circuit recovers the clock from the incoming USB data stream using four times over-sampling principle. It is able to track jitter and frequency drift specified by the USB specification.

Philips Serial Interface Engine (PSIE)

The Philips SIE implements the full USB protocol layer. It translates the electrical USB signals into data bytes and control signals. Depending upon the USB device address and the USB endpoint address, the USB data is directed to the correct endpoint buffer. The data transfer could be of bulk, isochronous, control or interrupt type.

The functions of the PSIE include: synchronization pattern recognition, parallel/serial conversion, bit stuffing/de-stuffing, CRC checking/generation, PID verification/generation, address recognition and handshake evaluation/generation.

The amount of bytes/packet on all endpoints is limited by the PSIE hardware to 8 bytes/packet, except for both isochronous endpoints (336 bytes/packet).

The analog front-end · The USB processor · Bit clock recovery

Page 10 of the Philips UDA1325 user manual — Memory Management Unit (MMU) and integrated RAM
Page 10 · click to enlarge
Page 10

Memory Management Unit (MMU) and integrated RAM

The Analog-to-Digital Interface (ADIF)

The MMU and integrated RAM handle the temporary data storage of all USB packets that are received or sent over the bus.

The ADIF is used for sampling an analog input signal from a microphone or line input and sending the audio samples to the USB interface. The ADIF consists of a stereo Programmable Gain Amplifier (PGA), a stereo Analog-to-Digital Converter (ADC) and Decimation Filters (DFs). The sample frequency of the ADC is determined by the ADC clock (see Section “The clock source of the analog-to-digital interface”). The user can also select a digital serial input instead of an analog input. In this event the sample frequency is determined by the continuous WS clock with a range between 5 to 55 kHz. Digital serial input is possible with four formats (I2S-bus, 16, 18 or 20 bits LSB-justified).

The MMU and integrated RAM handle the differences between data rate of the USB and the application allowing the microcontroller to read and write USB packets at its own speed.

The audio data is transferred via an isochronous data sink endpoint or source endpoint and is stored directly into the RAM. Consequently, no handshaking mechanism is used.

Audio Sample Redistribution (ASR)

The ASR reads the audio samples from the MMU and integrated RAM and distributes these samples equidistant over a 1 ms frame period. The distributed audio samples are translated by the digital I/O module to standard I2S-bus format or 16, 18 or 20 bits LSB-justified I2S-bus format. The ASR generates the bit clock output (BCKO) and the Word Select Output signal (WSO) of the I2S output.

Programmable Gain Amplifier circuit (PGA)

This circuit can be used for a microphone or line input. The input audio signals can be amplified by seven different gains (−3 dB, 0 dB, 3 dB, 9 dB, 15 dB, 21 dB and 27 dB).

The gain settings are given in Table 17.

The Analog-to-Digital Converter (ADC)

The stereo ADC of the UDA1325 consists of two 3rd-order Sigma-Delta modulators. They have a modified Ritchie-coder architecture in a differential switched capacitor implementation. The oversampling ratio is 128. Both ADCs can be switched off in power saving mode (left and right separate). The ADC clock is generated by the analog PLL or the ADC oscillator.

The microcontroller receives the control information selected from the USB by the USB processor. It can be used for handling the high-level USB protocols and the user interfaces. The microcontroller does not handle the audio stream.

The major task of the software process that is mapped upon the microcontroller, is to control the different modules of the UDA1325 in such a way that it behaves as a USB device.

The Decimation Filter (DF)

The decimator filter converts the audio data from 128fs down to 1fs with a word width of 8, 16 or 24 bits. This data can be transmitted over the USB as mono or stereo in 1, 2 or 3 bytes/sample. The decimator filters are clocked by the ADC clock.

The embedded 80C51 microcontroller is compatible with the 80C51 family of microcontrollers described in the 80C51 family single-chip 8-bit microcontrollers of “Data Handbook IC20”, which should be read in conjunction with this data sheet.

The internal ROM size is 12 kbyte. The internal RAM size is 256 byte. A Watchdog Timer is not integrated.

The 80C51 microcontroller

Page 11 of the Philips UDA1325 user manual — The clock source of the analog-to-digital interface
Page 11 · click to enlarge
Page 11

The clock source of the analog-to-digital interface

The clock source of the ADIF is the analog PLL or the ADC oscillator. The preferred clock source can be selected. The ADC clock used for the ADC and decimation filters is obtained by dividing the clock signal coming from the analog PLL or from the ADC oscillator by a factor Q.

Using the analog PLL the user can select 3 basic APLL clock frequencies (see Table 1).

By connecting the appropriate crystal the user can choose any clock signal between 8.192 and 14.08 MHz via the ADC oscillator.

Table 1 The analog PLL clock output frequencies

FCODE (1 AND 0)APLL CLOCK FREQUENCY (MHz) 0011.2896 018.1920 1012.2880 1111.2896

The dividing factor Q can be selected via the microcontroller. With this dividing factor Q the user can select a range of ADC clock signals allowing several different sample frequencies (see Table 2).

Table 2 ADC clock frequencies and sample frequencies based upon using the APLL as a clock source

APLL CLOCK FREQUENCY (MHz)DIVIDE FACTOR QADC CLOCK FREQUENCY (MHz)SAMPLE FREQUENCY (kHz) 8.192014.09632 22.04816 41.0248 80.512 (not supported)4 (not supported) 11.289615.644844.1 22.822422.05 41.411211.025 80.70565.5125 12.288016.14448 23.07224 41.53612 80.7686

Table 3 ADC clock frequencies and sample frequencies based upon using the OSCAD as a clock source

OSCAD CLOCK FREQUENCY (MHz)DIVIDE FACTOR QADC CLOCK FREQUENCY (MHz)SAMPLE FREQUENCY (kHz) f (1) oscQ(2)f /(2Q) oscf /(256Q)(3) osc
1. The oscillator frequency (and therefore the crystal) of OSCAD must be between 8.192 and 14.08 MHz.
2. The Q factor can be 1, 2, 4 or 8.
3. Sample frequencies below 5 kHz and above 55 kHz are not supported.
Page 12 of the Philips UDA1325 user manual — The Asynchronous Digital-to-Analog Converter (ADAC)
Page 12 · click to enlarge
Page 12

The Asynchronous Digital-to-Analog Converter (ADAC)

Table 4 Frequency domains for audio processing by the DSP

The ADAC receives audio data from the USB processor or from the digital I/O-bus. The ADAC is able to reconstruct the sample clock from the rate at which the audio samples arrive and handles the audio sound processing. After the processing, the audio signal is upsampled, noise-shaped and converted to analog output voltages capable of driving a line output.

DOMAINSAMPLE FREQUENCY (kHz) 15 to 12 212 to 25 325 to 40 440 to 55

The ADAC consists of:

The upsampling filters and variable hold function

  • A Sample Frequency Generator (SFG)

After the audio feature processing DSP two upsampling filters and a variable hold function increase the oversampling rate to 128fs.

  • FIFO registers
  • An audio feature processing DSP
  • Two digital upsampling filters and a variable hold register

A 3rd-order noise shaper converts the oversampled data to a noise-shaped bitstream for the FSDAC. The in-band quantization noise is shifted to frequencies well above the audio band.

  • A digital Noise Shaper (NS)
  • A Filter Stream DAC (FSDAC) with integrated filter and line output drivers.

The Sample Frequency Generator (SFG)

The Filter Stream DAC (FSDAC)

The SFG controls the timing signals for the asynchronous digital-to-analog conversion. By means of a digital PLL, the SFG automatically recovers the applied sampling frequency and generates the accurate timing signals for the audio feature processing DSP and the upsampling filters.

The FSDAC is a semi-digital reconstruction filter that converts the 1-bit data stream of the noise shaper to an analog output voltage. The filter coefficients are implemented as current sources and are summed at virtual ground of the output operational amplifier. In this way very high signal-to-noise performance and low clock jitter sensitivity is achieved. A post filter is not needed because of the inherent filter function of the DAC. On-board amplifiers convert the FSDAC output current to an output voltage signal capable of driving a line output.

The lock time of the digital PLL can be chosen (see Table 8). While the digital PLL is not in lock, the ADAC is muted. As soon as the digital PLL is in lock, the mute is released as described in Section “Soft mute control”.

First-In First-Out (FIFO) registers

The FIFO registers are used to store the audio samples temporarily coming from the USB processor or from the digital I/O input. The use of a FIFO (in conjunction with the SFG) is necessary to remove all jitter present on the incoming audio signal.

The sound processing DSP

A DSP processes the sound features. The control and mapping of the sound features is explained in Section “Controlling the playback features of the ADAC”. Depending on the sampling rate (fs) the DSP knows four frequency domains in which the treble and bass are regulated. The domain is chosen automatically.

The noise shaper

Page 13 of the Philips UDA1325 user manual — A DDRESS MODE
Page 13 · click to enlarge
Page 13

USB ENDPOINT DESCRIPTION

The UDA1325 has following six endpoints:

  • USB control endpoint 0
  • USB control endpoint 1
  • USB status interrupt endpoint 1
  • USB status interrupt endpoint 2
  • Isochronous data sink endpoint
  • Isochronous data source endpoint.

Table 5 Endpoint description

ENDPOINT

ENDPOINT

INDEX ENDPOINT TYPE DIRECTION MAX. PACKET

NUMBER

SIZE (BYTES)

0 0 control (default) out 8

1 2 control out 8

2 4 interrupt in 8

3 5 interrupt in 8

4 6 isochronous out out 336

5 7 isochronous in in 336

CONTROLLING THE PLAYBACK FEATURES

Controlling the playback features of the ADAC

The exchange of control information between the microcontroller and the ADAC is accomplished through a serial hardware interface comprising the following pins:

L3_DATAmicrocontroller interface data line
L3_MODEmicrocontroller interface mode line

L3_CLK: microcontroller interface clock line.

See also the description of Port 3 of the 80C51 microcontroller.

Information transfer through the microcontroller bus is organized in accordance with the so-called ‘L3’ format, in which two different modes of operation can be distinguished; address mode and data transfer mode.

The address mode is required to select a device communicating via the L3-bus and to define the destination registers for the data transfer mode. Data transfer for the UDA1325 can only be in one direction, from microcontroller to ADAC to program its sound processing features and other functional features.

A DDRESS MODE

The address mode is used to select a device (in this case the ADAC) for subsequent data transfer and to define the destination registers. The address mode is characterized by L3_MODE being LOW and a burst of 8 pulses on L3_CLK, accompanied by 8 data bits on L3_DATA. Data bits 0 and 1 indicate the type of the subsequent data transfer as shown in Table 6.

1 in 8 · 3 in 8

Page 14 of the Philips UDA1325 user manual — P ROGRAMMING THE SOUND PROCESSING AND OTHER FEATURES
Page 14 · click to enlarge
Page 14

Table 6 Selection of data transfer type

BIT1 BIT0 DATA TRANSFER TYPE

0 0 audio feature registers (volume left, volume right, bass and treble)

0 1 not used

1 0 control registers

1 1 not used

Data bits 7 to 2 represent a 6-bit device address, with bit 7 being the MSB and bit 2 the LSB. The address of the ADAC is 000101 (bits 7 to 2). In the event that the ADAC receives a different address, it will deselect its microcontroller interface logic.

D ATA TRANSFER MODE

The selection preformed in the address mode remains active during subsequent data transfers, until the ADAC receives a new address command. The data transfer mode is characterized by L3_MODE being HIGH and a burst of 8 pulses on L3_CLK, accompanied by 8 data bits. All transfers are bitwise, i.e. they are based on groups of 8 bits. Data will be stored in the ADAC after the eight bit of a byte has been received. The principle of a multibyte transfer is illustrated in the figure below.

L3MODE

L3CLOCK

L3DATA

address data byte #1 data byte #2 MGD018

P ROGRAMMING THE SOUND PROCESSING AND OTHER FEATURES

The sound processing and other feature values are stored in independent registers. The first selection of the registers is achieved by the choice of data transfer type. This is performed in the address mode, bits 1 and 0 (see Table 6). The second selection is performed by bit 7 and/or bit 6 of the data byte depending of the selected data transfer type.

Data transfer type ‘audio feature registers’

When the data transfer type ‘audio feature registers’ is selected 4 audio feature registers can be selected depending on bits 7 and 6 of the data byte (see Table 7).

thalt · ndbook, full pagewidth · address

Page 15 of the Philips UDA1325 user manual — REGISTER
Page 15 · click to enlarge
Page 15

Table 7 ADAC audio feature registers

BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0 REGISTER

0 0 VR5 VR4 VR3 VR2 VR1 VR0 volume right

0 1 VL5 VL4 VL3 VL2 VL1 VL0 volume left

1 0 X BB4 BB3 BB2 BB1 BB0 bass

1 1 X TR4 TR3 TR2 TR1 TR0 treble

The sequence for controlling the ADAC audio feature registers via the L3-bus is given in the figure below.

DATA_TRANSFER_TYPE

DEVICE ADDRESS = $5

(L3_MODE = LOW)

L3_DATA

0 1 0 1

ADDRESS LEFT VOLUME; TREBLE

REGISTER

RIGHT VOLUME; BASS

(L3_MODE = HIGH)

L3_DATA

X X X X

L3_CLK

MGS270

Data transfer type ‘control registers’

When the data transfer type ‘control registers’ is selected 2 general control registers can be selected depending on bit 7 of the data byte (see Table 7).

The sequence for controlling the ADAC control registers via the L3-bus is given in the figure below.

DATA_TRANSFER_TYPE

DEVICE ADDRESS = $5

(L3_MODE = LOW)

L3_DATA

1 1 0 1

REGISTER

ADDRESS DATA OF THE CONTROL REGISTER

(L3_MODE = HIGH)

L3_DATA

X X X X

L3_CLK

MGS269

Show 10 more labels / short text on this page
dbook, full pagewidth · bit 0 · bit 7 · bit 0 · bit 7 · dbook, full pagewidth · bit 0 · bit 7 · bit 0 · bit 7
Page 16 of the Philips UDA1325 user manual — REGISTER BIT DESCRIPTION VALUE COMMENT
Page 16 · click to enlarge
Page 16

Table 8 ADAC general control registers

REGISTER BIT DESCRIPTION VALUE COMMENT

Control register 0 0 reset ADAC 0 = not reset 1 = reset

1 soft mute control 0 = not muted 1 = mutes

2 synchronous/asynchronous 0 = asynchronous 1 = synchronous select 0

3 channel manipulation 0 = L -> L, R -> R 1 = L -> R, R -> L

4 de-emphasis 0 = de-emphasis off 1 = de-emphasis on

6 and 5 audio mode 00 = flat mode 01 = min. mode 10 = min. mode 11 = max. mode

7 selecting bit 0

Control register 1 1 and 0 serial I2S-bus input format 00 = I2S-bus 01 = 16-bit LSB justified 10 = 18-bit LSB justified 11 = 20-bit LSB justified

3 and 2 digital PLL mode 00 = adaptive 01 = fix state 1 10 = fix state 2 11 = fix state 3

4 digital PLL lock mode 0 = adaptive 1 = fixed select 1

6 and 5 digital PLL lock speed 00 = lock after 512 samples 01 = lock after 2048 samples 10 = lock after 4096 samples 11 = lock after 16348 samples

7 selecting bit 1

When the mute (bit 1 of control register 0) is active for the playback channel, the value of the sample is decreased smoothly to zero following a raised cosine curve. There are 32 coefficients used to step down the value of the data, each one being used 32 times before stepping to the next. This amounts to a mute transition of 23 ms at fs = 44.1 kHz. When the mute is released, the samples are returned to the full level again following a raised cosine curve with the same coefficients being used in reversed order.

The mute, on the master channel is synchronized to the sample clock, so that operation always takes place on complete samples.

select 00 · select 00 · Soft mute control

Page 17 of the Philips UDA1325 user manual — Volume control
Page 17 · click to enlarge
Page 17

The volume of the UDA1325 can be controlled from 0 dB down to −60 dB (in steps of 1 dB). Below −60 dB the audio signal is muted (−∞dB). The setting of 0 dB is always referenced to the maximum available volume setting. Independant volume control of the left and right channel is possible (balance control).

Table 9 Volume settings right playback channel

VR5 VR4 VR3 VR2 VR1 VR0 VOLUME (dB)

0

0 1 0

0 1 0 −1

0 1 1 −2

0 0 0 1 0 0 −3

1 0 0 −59

1 0 1 −60

1 0 −∞

1 −∞

Table 10 Volume settings left playback channel

VL5 VL4 VL3 VL2 VL1 VL0 VOLUME (dB)

0

0 1 0

0 1 0 −1

0 1 1 −2

0 0 0 1 0 0 −3

1 0 0 −59

1 0 1 −60

1 0 −∞

1 −∞

Volume control

Page 18 of the Philips UDA1325 user manual — TR4 TR3 TR2 TR1 TR0
Page 18 · click to enlarge
Page 18

For the playback channel, treble can be regulated in three audio modes: minimum, flat and maximum mode. In flat mode the audio is not influenced. In minimum and maximum mode, the treble range is from 0 to 6 dB in steps of 2 dB. The programmable treble filter is implemented digitally and has a fixed corner frequency of 3000 Hz for the minimum mode and 1500 Hz for the maximum mode. Because of the exceptional amount of programmable gain, treble should be used with adequate prior attenuation, using volume control.

Table 11 Treble settings

TR4 TR3 TR2 TR1 TR0

FLAT SET MIN. SET MAX. SET

0

0 1 0 0 0

0 0 0 1 0

0 0 0 1 1 0 0 0

0 0 1 0 0 0 2 2

0 0 1 0 1 0 2 2

0 0 1 1 0 0 2 2

0 0 1 1 1 0 2 2

0 1 0 4 4

0 1 0 0 1 0 4 4

0 1 0 1 0 0 4 4

0 1 0 1 1 0 4 4

0 1 1 0 0 0 6 6

0 1 1 0 1 0 6 6

0 1 1 1 0 0 6 6

0 1 0 6 6

0 6 6

1 0 6 6

For the playback channel, bass can be regulated in three audio modes: minimum, flat and maximum mode. In flat mode the audio is not influenced. In minimum mode the bass range is from 0 to approximately 14 dB in steps of 1.5 dB. In maximum mode, the bass range is from 0 to approximately 24 dB in steps of 2 dB. The programmable bass filters are implemented digitally and have a fixed corner frequency of 100 Hz for the minimum mode and 75 Hz for the maximum mode. Because of the exceptional amount of programmable gain, bass should be used with adequate prior attenuation, using volume control.

Treble control · TREBLE (dB) · Bass control

Page 19 of the Philips UDA1325 user manual — BB4 BB3 BB2 BB1 BB0
Page 19 · click to enlarge
Page 19

Table 12 Bass boost settings

BB4 BB3 BB2 BB1 BB0

FLAT SET MIN. SET MAX. SET

0

0 1 0 0 0

0 0 0 1 0

0 0 0 1 1 0 0 0

0 0 1 0 0 0 1.1 1.7

0 0 1 0 1 0 1.1 1.7

0 0 1 1 0 0 2.4 3.6

0 0 1 1 1 0 2.4 3.6

0 1 0 3.7 5.4

0 1 0 0 1 0 3.7 5.4

0 1 0 1 0 0 5.2 7.4

0 1 0 1 1 0 5.2 7.4

0 1 1 0 0 0 6.8 9.4

0 1 1 0 1 0 6.8 9.4

0 1 1 1 0 0 8.4 11.3

0 1 0 8.4 11.3

1 0 10.2 13.3

1 0 0 0 1 0 10.2 13.3

1 0 0 1 0 0 11.9 15.2

1 0 0 1 1 0 11.9 15.2

1 0 1 0 0 0 13.7 17.3

1 0 1 0 1 0 13.7 17.3

1 0 1 1 0 0 13.7 19.2

1 0 1 1 1 0 13.7 19.2

1 1 0 13.7 21.2

1 1 0 0 1 0 13.7 21.2

1 1 0 1 0 0 13.7 23.2

1 1 0 1 1 0 13.7 23.2

0 13.7 23.2

1 0 13.7 23.2

De-emphasis is controlled by bit 4 of control register 0. The de-emphasis filter can be switched on or off. The digital de-emphasis filter is dimensioned to produce the de-emphasis frequency characteristics for the sample rate 44.1 kHz. De-emphasis is synchronized to the sample clock, so that operation always takes place on complete samples.

BASS (dB) · De-emphasis

Page 20 of the Philips UDA1325 user manual — MGM110
Page 20 · click to enlarge
Page 20

Filter characteristics playback channel

The overall filter characteristic of the UDA1325 in flat mode is given in Fig.4 (de-emphasis off). The overall filter characteristic of the UDA1325 includes the filter characteristics of the DSP in flat mode plus the filter characteristic of the FSDAC (fs = 44.1 kHz)

MGM110

f (kHz) 10 20 30 40 50 60 70 80 90 100 0 −160

Fig.4 Overall filter characteristics of the UDA1325.

Show 11 more labels / short text on this page
−0 · handbook, full pagewidth · −20 · volume · (dB) · −40 · −60 · −80 · −100 · −120 · −140
Page 21 of the Philips UDA1325 user manual — LEFT
Page 21 · click to enlarge
Page 21

DSP extension port for enhanced playback audio processing

An external DSP can be used for adding extra sound processing features via the I2S inputs and outputs of the digital I/O module. The UDA1325 supports the standard I2S-bus data protocol and the LSB-justified serial data input format with word lengths of 16, 18 and 20 bits. Using the 4-pin digital I/O option the UDA1325 device acts as a master, controlling the BCKO and WSO signals. Using the 6-pin digital I/O option GP2, GP3 and GP4 are output pins (master) and GP0, GP1 and GP5 are input pins (slave).

The period of the WSO signal is determined by the number of samples in the 1 ms frame of the USB. This implies that the WSO signal does not have a constant time period, but is jittery.

The characteristic timing of the I2S-bus signals is illustrated in Figs 5 and 6.

LEFT

WS

RIGHT

BCK

DATA

LSB MSB

MGK003

Fig.5 Timing of digital I/O input signals.

Show 7 more labels / short text on this page
handbook, full pagewidth · ts;WS · th;WS · tBCK(H) tBCK(L) · tf tr · Tcy ts;DAT · th;DAT
Page 22 of the Philips UDA1325 user manual — MSB B2 B3 B4
Page 22 · click to enlarge
Page 22

white to force landscape pages to be rotated correctly when browsing through the pdf in the Acrobat reader. white to force landscape pages to be ...

This text is here in white to force landscape pages to be rotated correctly when browsing through the pdf in the Acrobat reader.This text is here in

_white to force landscape pages to be rotated correctly when browsing through the pdf in the Acrobat reader.This text is here inThis text is here in

MGK002

2 15 16 1

MSB LSB B2 B15

2 15 16 17 18 1

MSB B2 B3 B4 LSB B17

2 15 16 17 18 19 20 1

MSB B2 B3 B4 B5 B6 LSB B19

RIGHT

RIGHT

RIGHT

MSB B2 MSB LSB LSB MSB B2

>=8 >=8

LSB-JUSTIFIED FORMAT 16 BITS

LSB-JUSTIFIED FORMAT 18 BITS

LSB-JUSTIFIED FORMAT 20 BITS

INPUT FORMAT I 2 S-BUS

Fig.6 Input formats.

MSB LSB B2

2 15 16 17 18 1

LSB B17

2 15 16 17 18 19 20 1

MSB B2 B3 B4 B5 B6 LSB B19

B15

WS LEFT RIGHT

3 2 1 3 2 1

MSB B2 B3 B4

LEFT

LEFT

LEFT

BCK

DATA

WS

BCK

DATA

WS

BCK

DATA

WS

BCK

DATA

book, full pagewidth · 15 16 1

Page 23 of the Philips UDA1325 user manual — 3.4 PSIE_MMU_READY
Page 23 · click to enlarge
Page 23

PORT DEFINITION 80C51

Table 13 Port 1 of the 80C51 microcontroller

8 BIT PORT 1

BIT FUNCTION LOW HIGH COMMENT

1.0 ADAC_error no error error

1.1 GP1 general purpose pins

1.2 GP2

1.3 GP3

1.4 GP4

1.5 GP5

1.6 SCL I2C-bus

1.7 SDA

Table 14 Port 3 of the 80C51 microcontroller

8 BIT PORT 3

BIT FUNCTION LOW HIGH COMMENT

3.0 ASR_error no error error

3.1 PSIE_MMU_SUSPEND no suspend suspend suspend input from USB interface during normal operation or input from restart circuit

3.2 GP0 (INT0_N) general purpose pin

3.3 PSIE_MMU_INT (INT1_N) interrupt input from USB interface during normal operation or input from restart circuit

3.4 PSIE_MMU_READY

3.5 L3_MODE

3.6 L3_CLK

3.7 L3_DATA

Port 1 · Port 3

Page 24 of the Philips UDA1325 user manual — I NTERRUPT E NABLE REGISTER (IE)
Page 24 · click to enlarge
Page 24

MEMORY AND REGISTER SPACE 80C51

ADDRESS REGISTER RESET VALUE

Table 15 Register location and recommended values

ADDRESS REGISTER RESET VALUE

0800h PGA gain 09

0801h ADIF control 5C

I2C registers (SIO1 registers)

1000h clock shop settings 00

1001h reset control and APLL settings 00

1002h IO selection register 01

1003h power control 00

2000h ASR settings 8B

4000h data register PSIE

4001h command register PSIE

The UDA1325 supports up to five (of maximal 7) interrupt sources. Each interrupt source corresponds to an interrupt vector in the CPU program memory address space:

Table 16 Special function register location

ADDRESS REGISTER RESET VALUE

Source 0vector 0003h external interrupt 0 (INT0_N)
Source 1vector 000Bh Timer 0 interrupt
Source 2vector 0013h external interrupt 1 (INT1_N)
Source 3vector 001Bh Timer 1 interrupt
Source 4vector 0023h UART interrupt (not present)
Source 5vector 002Bh Timer 2 interrupt (not present)

Source 6: vector 0033h I2C interrupt.

I NTERRUPT E NABLE REGISTER (IE)

Each interrupt source can be individually enabled or disabled by setting or clearing a bit in IE. This register also contains a global interrupt enable bit (EA) which can be cleared to disable all interrupts at once.

Timer 0 and Timer 1 registers

7 6 5 4 3 2 1 0

0

EX0 (vector 0003h)) ET0 (vector 000Bh)) EX1 (vector 0013h) ET1 (vector 001Bh) ES0 (n.a.) ET2 (n.a.) ES1 (vector 0033h) EA

Show 31 more labels / short text on this page
Overview registers · Port registers · after Power-on reset · 80h P0 FFh · 90h P1 FFh · A0h P2 FFh · B0h P3 FFh · D8h S1CON 00h · D9h S1STA · DAh S1DAT · DBh S1ADR · Interrupts · CPU registers · 81h SP · 82h DPL · 83h DPH · D0h PSW · E0h ACC · F0h B · Interrupt registers · A8h IE 00h · B8h IP 00h · 88h T01CON 00h · Power On Value · 89h T01MOD 00h · 8Ah T0L 00h · 8Bh T1L 00h · 8Ch T0h 00h · 8Dh T1h 00h · PCON registers · 87h PCON 00h
Page 25 of the Philips UDA1325 user manual — ADDRESS REGISTER COMMENTS BIT VALUE
Page 25 · click to enlarge
Page 25

Table 17 PGA gain registers

ADDRESS REGISTER COMMENTS BIT VALUE

0800h PGA gain register reserved 7 X

PGA input selection 6 0 (do not change it)

PGA gain right channel 5, 4 and 3 000 = −3 dB 001 = 0 dB 010 = 3 dB 011 = 9 dB 100 = 15 dB 101 = 21 dB 110 = 27 dB 111 = 27 dB

PGA gain left channel 2, 1 and 0 000 = −3 dB 001 = 0 dB 010 = 3 dB 011 = 9 dB 100 = 15 dB 101 = 21 dB 110 = 27 dB 111 = 27 dB

Table 18 ADIF control registers

ADDRESS REGISTER COMMENTS BIT VALUE

0801h ADIF control register reserved 7 X

number of bits per audio sample to be transmitted to the host

6 and 5 00 = reserved

01 = 8 bits audio samples

10 = 16 bits audio samples

11 = 24 bits audio samples

mono/stereo selection 4 0 = mono

selection audio input recording channel

3 0 = digital serial audio input

1 = analog input

selection high-pass filter of ADIF (DC-filter)

2 0 = high-pass filter off

1 = high-pass filter on

I2S-bus input serial input format recording channel

1 and 0 00 = I2S-bus

01 = 16-bit LSB justified

10 = 18-bit LSB justified

11 = 20-bit LSB justified

Internal registers · 1 = stereo

Page 26 of the Philips UDA1325 user manual — ADDRESS REGISTER COMMENTS BIT VALUE
Page 26 · click to enlarge
Page 26

Table 19 Clock shop register

ADDRESS REGISTER COMMENTS BIT VALUE

1000h clock shop settings selection ADC clock source 7 0 = ADC clock from APLL

1 = ADC clock from OSCAD

divide factor Q 6 and 5 00 = ADC clock divided-by-1

01 = ADC clock divided-by-2

10 = ADC clock divided-by-4

11 = ADC clock divided-by-8

clock ADAC 4 0 = enable 1 = disable

clock 48 MHz internal 3 0 = enable 1 = disable

clock recovered by PSIE 2 0 = enable 1 = disable

ADC clock 1 0 = enable 1 = disable

OSCAD oscillator 0 0 = power on 1 = power off

Table 20 Reset control and APLL register

ADDRESS REGISTER COMMENTS BIT VALUE

1001h reset control and APLL settings

fcode (1 and 0) clock frequency selection APLL

7 and 6 00 = 256 × 44.1 kHz 01 = 256 × 32 kHz 10 = 256 × 48 kHz 11 = 256 × 44.1 kHz

reset ADAC 4 0 = reset off 1 = reset on

reset MMU 3 0 = reset off 1 = reset on

reset digital I/O-interface 2 0 = reset off 1 = reset on

reset ADIF 1 0 = reset off 1 = reset on

reserved 5 X · reserved 0 X

Page 27 of the Philips UDA1325 user manual — ADDRESS REGISTER COMMENTS BIT VALUE
Page 27 · click to enlarge
Page 27

Table 21 I/O selection register

ADDRESS REGISTER COMMENTS BIT VALUE

1002h I/O selection register microcontroller control on 48 MHz oscillator 7 0 = UPC control disabled (48 MHz oscillator is enabled)

1 = UPC control enabled

audio format 6 and 5 00 = 4-pins I2S 01 = 6-pins I2S 10 = 3-pins I2S (only input) 11 = 3-pins I2S (only input)

GP4 I/O if BIT0 = 1 4 0 = output 1 = input

GP3 I/O if BIT0 = 1 3 0 = output 1 = input

GP2 I/O if BIT0 = 1 2 0 = output 1 = input

GP1 I/O if BIT0 = 1 1 0 = output 1 = input

GP4 to GP1 function 0 0 = I2S usage 1 = general purpose usage

Table 22 Power control register

ADDRESS REGISTER COMMENTS BIT VALUE

1003h power control register analog modules

suspend input selection for P3.1 of the microcontroller

7 0 = suspend from USB interface connected to P3.1 during normal operation 1 = suspend from restart circuit connected to P3.1 (e.g. after power-down)

interrupt input selection for P3.3 (INT1_N) of the microcontroller

6 0 = interrupt from USB interface connected to P3.3 during normal operation 1 = interrupt from restart circuit connected to P3.3 (e.g. after power-down)

power APLL 5 0 = power on 1 = power off

power FSDAC 4 0 = power on 1 = power off

power ADC left 3 0 = power on 1 = power off

power ADC right 2 0 = power on 1 = power off

power PGA left 1 0 = power on 1 = power off

power PGA right 0 0 = power on 1 = power off

Page 28 of the Philips UDA1325 user manual — START-UP BEHAVIOUR AND POWER MANAGEMENT
Page 28 · click to enlarge
Page 28

Table 23 ASR control register

ADDRESS REGISTER COMMENTS BIT VALUE

2000h ASR control register robust word clock 7 0 = off (not recommended) 1 = on (recommended)

serial I2S-bus output format digital I/O interface

6 and 5 00 = I2S-bus

01 = 16-bit LSB justified

10 = 18-bit LSB justified

11 = 20-bit LSB justified

phase inversion (on right mono output)

4 0 = mono phase inversal off

1 = mono phase inversal on

bits per sample modi 3 and 2 00 = reserved

01 = 8-bit audio

10 = 16-bit audio

11 = 24-bit audio

mono or stereo operation 1 0 = mono

ASR register start-up mode 0 0 = stop (e.g. at alternate setting with bandwidth equal to zero) 1 = go

START-UP BEHAVIOUR AND POWER MANAGEMENT

Start-up of the UDA1325

After power-on (of VDDA1), an internal Power-on reset signal becomes HIGH after a certain RC time. This RC time is created by using the internal resistor (2 × 50 kΩ) divider for creating the reference voltage for the FSDAC in combination with the capacitor connected externally to the VREFDA pin. The FSDAC and the internal resistor divider are supplied by VDDA1 and VSSA1. The RC time can be calculated using R = 25000 Ω and C = Cref.

During 20 ms after Power-on reset becomes HIGH the UDA1325 has to initiate the internal registers. During this initialisation, the user should prevent indicating the ‘connected’ status to the USB-host. This can be done by forcing the DP-line LOW (i.e. via one of the GP pins).

The total current drawn from the USB supply (for i.e. bus-powered operation of the UDA1325 application) must be less than 500 µA in suspend mode. In order to reach that low current target, the total power dissipation of the UDA1325 can be reduced by disabling all internal clocks and switching off all internal analog modules.

1 = stereo · Power Management

Page 29 of the Philips UDA1325 user manual — I N NORMAL OPERATION MODE
Page 29 · click to enlarge
Page 29

A T INITIALISATION TIME

  • Bit 7of the power control register (mux_ctrl_suspend) must be set to ‘1’, in order to connect the CLK_ON of the USB processor with P3.1 of the microcontroller
  • Bit 6 of the power control register (mux_ctrl_int1) must be set to ‘0’, in order to connect the PSIE_MMU_INT output pin of the USB processor with P3.3 (INT1_N) of the microcontroller
  • Bit 7of the I/O selection register must be set to ‘1’, in order to enable the power-on control of the 48 MHz crystal oscillator automatically by the microcontroller.

I N NORMAL OPERATION MODE

In normal operation working mode, a suspend can be initiated by the falling edge of the CLK_ON output signal of the USB processor. This falling edge comes about 2 ms after the rising edge of the PSIE_MMU_SUSPEND output signal of the USB processor. At this moment, several actions should be taken by the microcontroller:

  • All analog modules of the UDA1325 must be switched off; this can be done by setting bits 5 to 0 of the power control register to ‘1’ and bit 0 of the clock shop register to ‘1’
  • Bit 6 of the power control register (mux_ctrl_int1) must be set to ‘1’, in order to awake from power-down by the CLK_ON signal of the USB processor
  • Put all GP pins in the high or low state (depending of how they are used in the UDA1325 application)
  • Put the microcontroller in Power-down mode. This can be done via the PCON register of the microcontroller. This results in an automatically switching off the 48 MHz crystal oscillator and with that all internal clocks (if they are enabled).

On the rising edge of the CLK_ON output signal, the 48 MHz crystal oscillator will be switched on automatically and with that all internal clocks (if they are enabled). At the same time, a counter starts counting for 2048 clock cycles (170 µs). This time is necessary for stabilising the 48 MHz clock of the 48 MHz crystal oscillator.

When the counter reaches its end value (after 2048 cycles), a rising edge will be detected on the P3.3 (INT1_N) of the microcontroller. At this moment, following actions should be taken by the microcontroller:

  • The Power-down mode of the microcontroller must be switched off
  • Re-initialise all GP pins
  • All analog modules of the UDA1325 must be switched on; this can be done by setting bits 5 to 0 of the power control register to ‘0’ and bit 0 of the clock shop register to ‘0’
  • Bit 6 of the power control register (mux_ctrl_int1) must be set to ‘0’, in order to connect the PSIE_MMU_INT output pin of the USB processor again with P3.3 (INT1_N) of the microcontroller.

The UDA1325 is now back in its normal operation mode and can be put back in power reduction mode by the falling edge of the CLK_ON signal of the USB processor.

Page 30 of the Philips UDA1325 user manual — COMMAND SUMMARY
Page 30 · click to enlarge
Page 30

COMMAND SUMMARY

COMMAND NAME RECIPIENT CODING DATA PHASE

Set address/enable device D0h write 1 byte

Read address/enable device D0h read 1 byte

Set endpoint enable device D8h write 1 byte

Read endpoint enable device D8h read 1 byte

Set mode device F3h write 1 byte

Read interrupt register device F4h read 1 byte

Select endpoint control OUT 00h read 1 byte (optional)

control IN 01h read 1 byte (optional)

other endpoints 00h + endpoint index read 1 byte (optional)

Get endpoint status control OUT 40h read 1 byte

control IN 41h read 1 byte

other endpoints 40h + endpoint index read 1 byte

Set endpoint status control OUT 40h write 1 byte

control IN 41h write 1 byte

other endpoints 40h + endpoint index write 1 byte

Read buffer selected endpoint F0h read n bytes

Write buffer selected endpoint F0h write n bytes

Acknowledge setup selected endpoint F1h none

Clear buffer selected endpoint F2h none

Validate buffer selected endpoint FAh none

Read current frame number F5h read 1 or 2 bytes

Initialization commands · Data flow commands · General commands

Page 31 of the Philips UDA1325 user manual — S ET MODE
Page 31 · click to enlarge
Page 31

COMMAND DESCRIPTIONS

BIT DESCRIPTION

This chapter describes the commands that can be used by the microcontroller to control the USB processor. There are three basic types of commands:

Address the value written becomes the device address

Enable a ‘1’ enables this function

  • Initialization commands
  • Data flow commands

R EAD ADDRESS / ENABLE

  • General commands.

Command: D0h.

A command is represented by an 8 bit code. It can be followed by one or more data write cycles or one or more read cycles or a combination. The PSIE_MMU_READY output connected to Port 3.4 of the microcontroller indicates that the previous action (command write, data read or data write) has completed. A new action can only be initiated if PSIE_MMU_READY is TRUE. The data is valid from the moment PSIE_MMU_READY becomes TRUE.

Data: read 1 byte.

The read address/enable command is used to read the USB assigned address and the enable bit of the device. The format of the data phase is the same as for the set address/enable command.

S ET ENDPOINT ENABLE

Command: D8h.

The PSIE contains a number of interrupt registers, one for each endpoint. Every time a transition occurs, the interrupt flag for the involved endpoint is set. The PSIE_MMU_INT connected to Port 3.3 is an OR function of all interrupt registers.

Data: write 1 byte.

The set endpoint enable command is used to set the enable bits for the non default endpoints.

7 6 5 4 3 2 1 0

X 0

Initialization commands are used during the enumeration process of the USB network. They are used to set the USB assigned address, enable endpoints and select the configuration of the device.

If the enable bit is ‘1’, the non default endpoints are enabled, if ‘0’, the non default endpoints are disabled. The function then only responds to the default control endpoint.

S ET ADDRESS / ENABLE

Command: D0h.

After bus reset, the enable bit is set to ‘0’.

Data: write 1 byte.

The set address/enable command is used to set the USB assigned address and enable the function. The device always powers up disabled and should be enabled after a bus reset.

R EAD ENDPOINT ENABLE

Command: D8h.

Data: read 1 byte.

The read endpoint enable command is used to read the enable bit for the non default endpoints of the function. The format of the data phase is the same as for the set endpoint enable command.

0 1 2 3 4 5 6 7

0 Power On Value

S ET MODE

Command: F3h.

Data: write 1 byte.

Show 6 more labels / short text on this page
Table 24 · Command procedure · Power On Value · Initialization commands · Enable Reserved · Address Enable
Page 32 of the Philips UDA1325 user manual — R EAD INTERRUPT REGISTER
Page 32 · click to enlarge
Page 32

An interrupt is also generated after a bus reset. When the interrupt register consists of all zeros, and an interrupt was generated, there was a bus reset. The interrupt is cleared when the interrupt register is read.

7 6 5 4 3 2 1 0

Bus Reset 1 0 0 Reset value

T T F F T

IsoOut IsoIn IntIsoOut IntIsoIn ErrorDebugMode AlwaysPLLClock Reserved Reserved

7 6 5 4 3 2 1 0

0

Control OUT Control IN Endpoint 1 OUT Endpoint 1 IN Endpoint 2 IN Endpoint 3 IN Endpoint 4 OUT Endpoint 5 IN

Reset value: gives the value of the bits after Power-on reset. Bus reset: a ‘F’ indicates that the value of the bit is not changed during a bus reset. a ‘T’ indicates that during a bus reset, the bit is reset to its reset value.

S ELECT ENDPOINT

Command: 00h + endpoint index.

BIT DESCRIPTION

Data: optional read 1 byte.

IsoOut ISO out endpoint can be used

The select endpoint command initializes an internal pointer to the start of the selected buffer. Optionally, this command can be followed by a data read. Bit 0 is low if the buffer is empty and high if the buffer is full. There is one command for every endpoint.

IsoIn ISO in endpoint can be used

IntIsoOut allow interrupt from ISO out endpoint

IntIsoIn allow interrupt from ISO in endpoint

7 6 5 4 3 2 1 0

X 0

ErrorDebugMode Setting chip in debug mode

AlwaysPLLClock the PLL clock must keep on running

G ET ENDPOINT STATUS

Command: 40h + endpoint index.

Data flow commands are used to manage the data transmission between the USB endpoints and the host. Much of the data flow is initiated via the interrupt to the microcontroller. The microcontroller uses these commands to access the endpoint buffers and determine whether the endpoint buffers have valid data.

Data: read 1 byte.

The get endpoint status command is followed by one data read that returns the status of the last transaction of the selected endpoint. This command also resets the corresponding interrupt flag in the interrupt register, and clears the status, indicating that it was read. There is one command for every endpoint.

R EAD INTERRUPT REGISTER

Command: F4h.

7 6 5 4 3 2 1 0

Data: read 1 byte.

0

The read interrupt register command returns the value of the interrupt register. Every time a packet is received or transmitted, an interrupt will be generated and a flag specific to the physical endpoint will be set in the interrupt register. Reading the status of the endpoint will clear the flag.

Error Code Setup Packet Data 0/1 Packet Previous Status not Read

Show 8 more labels / short text on this page
Power On Value · Table 25 · Power On Value · Full/Empty · Reserved · Data flow commands · Power On Value · Data Receive/Transmit
Page 33 of the Philips UDA1325 user manual — BIT DESCRIPTION
Page 33 · click to enlarge
Page 33

Table 26 Error codes

S ET ENDPOINT STATUS

Command: 40h + endpoint index.

ERROR

CODE RESULT

Data: write 1 byte.

This command is used to stall or unstall an endpoint. Only the least significant bit has a meaning. When the stalled bit is equal to 1, the endpoint is stalled, when equal to 0, the endpoint is unstalled. There is one command for every endpoint.

0001 PID encoding error; bits 7 to 4 in the PID token are not the inversion of bits 3 to 0

0010 PID unknown; PID encoding is valid, but PID does not exist

0011 unexpected packet; packet is not of the type expected (token, data or acknowledge), or SETUP token received on non-control endpoint

A stalled control endpoint is automatically unstalled when it receives a SETUP token, regardless of the contents of the packet. If the endpoint should stay in stalled state, the microcontroller should restall it.

0100 token CRC error

When a stalled endpoint is unstalled, it is also re-initialized. This means that its buffer is flushed and the next DATA PID that will be sent or expected (depending on the direction of the endpoint) is DATA0.

0101 data CRC error

0110 time out error

1001 sent or received NAK

0 1 2 3 4 5 6 7

1010 sent stall, a token was received, but the endpoint was stalled

X Power On Value 0

1011 overflow error, the received data packet was larger then the buffer size of the selected endpoint

1100 sent empty packet (ISO only)

R EAD BUFFER

Command: F0h.

1110 error in sync

Data: read n bytes (max. 10).

1111 wrong data PID

The read buffer command is followed by a number of data reads, which returns the contents of the selected endpoint data buffer. After each read, the internal buffer pointer is incremented by 1.

BIT DESCRIPTION

Data receive/transmit a ‘1’ indicates data has been received or transmitted successfully

The buffer pointer is not reset to the buffer start by the read buffer command. This means that reading a buffer can be interrupted by any other command (except for select endpoint).

Error code see Table 26

Setup packet a ‘1’ indicates the last received packet had a SETUP token (this will always read ‘0’ for IN buffers)

Data 0/1 packet a ‘1’ indicates the last received packet had a DATA 1 PID

Previous status not read a ‘1’ indicates a second event occurred before the previous status was read

Show 6 more labels / short text on this page
0000 no error · 0111 babble error · 1000 unexpected end-of-packet · Stalled Reserved · 1101 bitstuff error · Table 27
Page 34 of the Philips UDA1325 user manual — A CKNOWLEDGE S ETUP
Page 34 · click to enlarge
Page 34

The data in the buffer are organized as follows:

acknowledged explicitly that it has seen the SETUP packet.

Byte 0transfer successful, number of data bytes (MSB)
Byte 1number of data bytes (LSB)

If the microcontroller is reading the data from a SETUP packet, and a new SETUP packet arrives, the device must accept this new SETUP packet. So the data, currently being read by the microcontroller, is overwritten with the new packet. On the arrival of the new packet, the commands validate buffer and clear buffer are disabled. If the microcontroller has finished reading the data from the buffer, it will try to clear the buffer. The device will ignore this command, so the new SETUP packet in the buffer is not cleared. The microcontroller will now detect the interrupt of the new SETUP packet and will start reading the new data in the buffer.

Byte 2data byte 0
Byte 3data byte 1
Byte 4data byte 2
Byte 5data byte 3
Byte 6data byte 4
Byte 7data byte 5
Byte 8data byte 6

Byte 9: data byte 7.

Bytes 0 and 1 indicate the number of bytes in the buffer. Byte 0 is the Most Significant Byte (MSB). Byte 1 is the Least Significant Byte (LSB). Only bits 1 and 0 of byte 0 are used in the number of bytes indication.

A SETUP token can be followed by an IN token. After the SETUP token, the microcontroller will start filling the IN buffer. A SETUP token will clear the IN buffer. This avoids the following problem: after a SETUP token, the microcontroller fills the IN buffer. If the SETUP token is followed by a SETUP token and shortly followed by an IN token, the device will send the contents of the IN buffer to the host. The IN buffer was filled after the first SETUP token. That is why after a SETUP token the IN buffer is cleared.

Bit 7 of byte 0 indicates if the transaction was successful (bit 7 is ‘1’ if the transaction was successful). Bits 6 to 2 of byte 0 are reserved.

W RITE BUFFER

Command: F0h.

If the microcontroller is still filling the buffer when the second SETUP token arrives, the SETUP token will clear the IN buffer. If the microcontroller has filled the IN buffer, it will validate the buffer. So clearing the IN buffer on receiving a SETUP token is not enough.

Data: write n bytes (max. 10).

The write buffer command is followed by a number of data writes, which load the endpoint buffer. After each write, the internal buffer pointer is incremented by 1.

The buffer pointer is not reset to the buffer start by the write buffer command. This means that writing a buffer can be interrupted by any other command (except for select endpoint).

If a SETUP token is received, the device will also disable the validate buffer command for the IN buffer. If the microcontroller needs to fill the buffer after a SETUP token, the command acknowledge setup command must be sent to enable the validate buffer command.

The data must be organized in the same way as described in the read buffer command. Bits 7 to 2 of byte 0 are reserved and must be filled with zeros.

C LEAR BUFFER

Command: F2h.

A CKNOWLEDGE S ETUP

Data: none.

Command: F1h.

When a packet is received completely, an internal endpoint buffer full flag is set. All subsequent packets will be refused by returning a NACK to the host. When the microcontroller has read the data, it should free the buffer by the clear buffer command. When the buffer is cleared, new packets will be accepted.

Data: none.

The arrival of a SETUP packet flushes the IN buffer and disables the validate buffer and clear buffer commands for both IN and OUT endpoints.

The microcontroller needs to re-enable these commands by the acknowledge setup command. This ensures that the last SETUP packet stays in the buffer and no packet can be sent back to the host until the microcontroller has

Page 35 of the Philips UDA1325 user manual — CR2 CR1 CR0 I 2 C BIT FREQUENCY
Page 35 · click to enlarge
Page 35

V ALIDATE BUFFER

Command: FAh.

The CPU can read from and write to this 8-bit SFR. Two bits are effected by the SIO1 hardware: the SI bit is set when a serial interrupt is requested, and the STO bit is cleared when a STOP condition is present on the I2C-bus. The STO bit is also cleared when ENS1 = ‘0’. Reset initializes S1CON to 00h.

Data: none.

When the microcontroller has written data into an IN buffer, it should set the buffer full flag by the validate buffer command. This indicates that the data in the buffer are valid and can be sent to the host when the next IN token is received.

7 6 5 4 3 2 1 0

0

CR0 CR1 AA SI STO STA ENS1 CR2

R EAD CURRENT FRAME NUMBER

Command: F5h.

Data: read 1 or 2 bytes.

This command is followed by one or two data reads and returns the frame number of the last successfully received SOF. The frame number is eleven bits wide. The frame number is returned least significant byte first. In case the user is only interested in the lower 8 bits of the frame number only the first byte needs to be read.

CR2, 1 AND 0 - THE CLOCK RATE BITS

These three bits determine the serial clock frequency when SIO1 is in a master mode.

The various serial rates are shown in Table 28.

I 2 C MASTER/SLAVE INTERFACE

Table 28 Serial clock rates (SCL line)

The I2C module implements a master/slave I2C-bus interface with integrated shift register, shift timing generation and slave address recognition. It is compliant to the I2C-bus specification IC20/Jan92. I2C standard mode (100 kHz SCL) and fast mode (400 kHz) are supported. Low speed mode and extended 10 bit addressing are unsupported.

CR2 CR1 CR0 I 2 C BIT FREQUENCY

0 0 0 1200

0 0 1 600

0 1 0 400

0 1 1 300

1 0 0 150

Characteristics of the I2C-bus

1 0 1 100

The I2C-bus is for 2-way, 2-line communication between different ICs or modules. The two lines are a serial data line (SDA) and a Serial Clock Line (SCL). Both lines must be connected to VDDE via a pull-up resistor.

1 1 0 75

1 1 1 3.9 ... 501

The timing definition of the I2C-bus is given in Fig.7.

When the CR bits are ‘111’, the maximum bit rate for the data transfer will be derived from the Timer 1 overflow rate divided by 2 (i.e. every time the Timer 1 overflows, the SCL signal will toggle).

For a detailed description of the I2C-bus protocol refer to Philips Integrated Circuits Data Handbook IC20, 8XC552.

The programmer’s view of the I2C library function is -with one exception- identical to that of the 8XC552 microcontroller. Only the bit rate frequency selection in S1CON and the handling of the Timer 1 overflow information deviates to accommodate 400 kHz operation.

Show 5 more labels / short text on this page
S1CON register · General commands · Power On Value · (kHz) · Programmer’s view
Page 36 of the Philips UDA1325 user manual — SDA
Page 36 · click to enlarge
Page 36

white to force landscape pages to be rotated correctly when browsing through the pdf in the Acrobat reader. white to force landscape pages to be ...

This text is here in white to force landscape pages to be rotated correctly when browsing through the pdf in the Acrobat reader.This text is here in

_white to force landscape pages to be rotated correctly when browsing through the pdf in the Acrobat reader.This text is here inThis text is here in

MBC611 P S Sr P

t SP t HD;STA

t SU;STA t SU;DAT

Fig.7 Definition of timing of the I2C-bus.

SDA

SCL

Show 9 more labels / short text on this page
tSU;STO · t f · handbook, full pagewidth · t HIGH · t HD;DAT · t r · t HD;STA · t LOW · t BUF
Page 37 of the Philips UDA1325 user manual — RECOMMENDED OPERATING CONDITIONS
Page 37 · click to enlarge
Page 37

LIMITING VALUES In accordance with the Absolute Maximum Rating System (IEC 134).

SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT

VI/O DC input/output voltage range −0.5 − VDDE V

IO output current VDDE = 5.0 V − − 4 mA

Tj junction temperature 0 − 125 °C

Tstg storage temperature −55 − +150 °C

Tamb operating ambient temperature 0 25 70 °C

Ves electrostatic handling note 1 −3000 − +3000 V

1. Equivalent to discharging a 100 pF capacitor through a 1.5 k Ω series resistor.
2. Equivalent to discharging a 200 pF capacitor through a 2.5 µ H series conductor.

THERMAL CHARACTERISTICS

SYMBOL PARAMETER CONDITIONS VALUE UNIT

Rth(j-a) thermal resistance from junction to ambient

UDA1325PS in free air 48 K/W

UDA1325H in free air 48 K/W

RECOMMENDED OPERATING CONDITIONS

SYMBOL PARAMETER MIN. TYP. MAX. UNIT

VDDE supply voltage periphery (I/O) 4.75 5.0 5.25 V

VDD supply voltage (core) 3.0 3.3 3.6 V

VI DC input voltage range

for D+ and D− 0.0 − VDD V

for VINL and VINR − 0.5VDD − V

for digital I/Os 0.0 − VDDE V

All digital I/Os · Temperature values · Electrostatic handling

Page 38 of the Philips UDA1325 user manual — 0.8 − 2.0 V
Page 38 · click to enlarge
Page 38

DC CHARACTERISTICS VDDE = 5.0 V; VDD = 3.3 V; Tamb = 25 °C; fosc = 48 MHz; fs = 44.1 kHz; unless otherwise specified.

SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT

VDDE digital supply voltage periphery 4.75 5.0 5.25 V

VDDI digital supply voltage core 3.0 3.3 3.6 V

VDDA1 analog supply voltage 1 3.0 3.3 3.6 V

VDDA2 analog supply voltage 2 3.0 3.3 3.6 V

VDDA3 analog supply voltage 3 3.0 3.3 3.6 V

VDDO operational amplifier supply voltage 3.0 3.3 3.6 V

VDDX crystal oscillator supply voltage 3.0 3.3 3.6 V

IDDE digital supply current periphery note 1 − 3.7 − mA

IDDI digital supply current core − 39.0 − mA

IDDA1 analog supply current 1 − 3.6 − mA

IDDA2 analog supply current 2 − 8.0 − mA

IDDA3 analog supply current 3 − 0.9 9.0(2) mA

IDDO operational amplifier supply current − 3.0 − mA

IDDX crystal oscillator supply current − 1.2 13.0(3) mA

Ptot total power dissipation − 200 − mW

Pps total power dissipation in power saving mode

Inputs/outputs D+ and D−

VI static DC input voltage −0.5 − VDDI V

VO(H) static DC output voltage HIGH RL = 15 kΩ connected to GND

2.8 − 3.6 V

VO(L) static DC output voltage LOW RL = 1.5 kΩ connected to VDD

− − 0.3 V

ILO high impedance data line output leakage current

− − 10 µA

VI(diff) differential input sensitivity 0.2 − − V

VCM(diff) differential common mode range 0.8 − 2.5 V

VSE(R)(th) single-ended receiver threshold voltage

0.8 − 2.0 V

CIN transceiver input capacitance pin to GND − − 20 pF

VIL LOW-level input voltage − − 0.3VDDE V

VIH HIGH-level input voltage 0.7VDDE − VDDE V

ILI input leakage current − − 1 µA

CI input capacitance − − 5 pF

Supplies · Digital input pins

Page 39 of the Philips UDA1325 user manual — − 11 − Ω
Page 39 · click to enlarge
Page 39

SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT

Vref(AD) reference voltage PGA and ADC − 0.5VDDA2 − V

Vref(ADC)(pos) positive reference voltage of the ADC

− V DDA2 − V

Vref(ADC)(neg) negative reference voltage of the ADC

− 0.0 − V

VI(PGA) DC input voltage VINL and VINR of the PGA

− 0.5V DDA2 − V

RI(PGA) DC input resistance at VINL and VINR of the PGA

− 12.5 − kΩ

Vref(DA) reference voltage DAC − 0.5VDDA1 − V

VO(CM) common mode output voltage − 0.5VDDA1 − V

RO(VOUT) output resistance at VOUTL and VOUTR

− 11 − Ω

RO(L) output load resistance 2.0 − − kΩ

CO(L) output load capacitance − − 50 pF

1. This value depends strongly on the application. The specified value is the typical value obtained using the application diagram as illustrated in Fig.8.
2. At start-up of the OSCAD oscillator.
3. At start-up of the OSC48 oscillator.
4. Exclusive the IDDE current which depends on the components connected to the I/O pins.

PGA and ADC · Filter stream DAC

Page 40 of the Philips UDA1325 user manual — SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
Page 40 · click to enlarge
Page 40

AC CHARACTERISTICS VDDE = 5.0 V; VDDI = 3.3 V; Tamb = 25 °C; fosc = 48 MHz; fs = 44.1 kHz; unless otherwise specified.

SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT

Driver characteristics D+ and D− (full-speed mode)

fo(s) audio sample output frequency 5 − 55 kHz

tr rise time CL = 50 pF 4 − 20 ns

tf fall time CL = 50 pF 4 − 20 ns

trf(m) rise/fall time matching (tr/tf) 90 − 110 %

Vcr output signal crossover voltage 1.3 − 2.0 V

Ro(drive) driver output resistance steady-state drive 28 − 43 Ω

Data source timings D+ and D− (full-speed mode)

fi(s) audio sample input frequency 5 − 55 kHz

ffs(D) full speed data rate 11.97 12.00 12.03 Mbits/s

tfr(D) frame interval 0.9995 1.0000 1.0005 ms

tJ1(diff) source differential jitter to next transition

−3.5 0.0 +3.5 ns

tJ2(diff) source differential jitter for paired transitions

−4.0 0.0 +4.0 ns

tW(EOP) source end of packet width 160 − 175 ns

tEOP(diff) differential to end of packet transition skew

−2.0 − +5.0 ns

tJR1 receiver data jitter tolerance to next transition

−18.5 0.0 +18.5 ns

tJR2 receiver data jitter tolerance for paired transitions

−9.0 0.0 +9.0 ns

tEOPR1 end of packet width at receiver must reject as end of packet

40 − − ns

tEOPR2 end of packet width at receiver must accept as end of packet

82 − − ns

Serial input/output data timing

fs system clock frequency − 12 − MHz

fi(WS) word selection input frequency 5 − 55 kHz

tr rise time − − 20 ns

tf fall time − − 20 ns

tBCK(H) bit clock HIGH time 55 − − ns

tBCK(L) bit clock LOW time 55 − − ns

ts;DAT data set-up time 10 − − ns

th;DAT data hold time 20 − − ns

ts;WS word selection set-up time 20 − − ns

th;WS word selection hold time 10 − − ns

Page 41 of the Philips UDA1325 user manual — SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
Page 41 · click to enlarge
Page 41

SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT

SDA and SCL lines for 100 kHz I2C devices

fSCL SCL clock frequency 0 − 100 kHz

tBUF bus free time between a STOP and START condition

4.7 − − µs

tHD;STA hold time (repeated) START condition

4.0 − − µs

tLOW LOW period of the SCL clock 4.7 − − µs

tHIGH HIGH period of the SCL clock 4.0 − − µs

tSU;STA set-up time for a repeated START condition

4.7 − − µs

tSU;STO set-up time for STOP condition 4.0 − − µs

tHD;DAT data hold time 5.0 − − µs

tSU;DAT data set-up time 250 − − ns

tr rise time of both SDA and SCL signals

− − 1000 ns

tf fall time of both SDA and SCL signals

− − 300 ns

CL(bus) capacitive load for each bus line − − 400 pF

Oscillator 1 (system clock)

fosc oscillator frequency − 48 − MHz

δ duty factor − 50 − %

gm transconductance 12.8 22.1 30.2 mS

Ro output resistance 0.6 1.1 2.3 kΩ

Ci(XTAL1a) parasitic input capacitance XTAL1a 4.5 4.8 5.2 pF

Ci(XTAL2a) parasitic input capacitance XTAL2a 4.1 4.6 5.0 pF

Istart start-up current 3.7 7.6 13.0 mA

Oscillator 2 (for ADC clock)

fosc oscillator frequency 8.192 − 14.08 MHz

δ duty cycle − 50 − %

gm transconductance 8.1 13.6 18.1 mA/V

Ro output resistance 1.3 2.0 4.0 kΩ

Ci(XTAL1b) parasitic input capacitance XTAL1b 5.0 5.4 5.7 pF

Ci(XTAL2b) parasitic input capacitance XTAL2b 4.1 4.6 5.0 pF

Istart start-up current 2.4 5.0 8.4 mA

Page 42 of the Philips UDA1325 user manual — SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
Page 42 · click to enlarge
Page 42

SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT

Analog PLL (for ADC clock)

fclk(PLL) PLL clock frequency 8.1920 11.2896 12.2880 MHz

δ duty factor − 50 − %

tstrt(PO) start-up time after power-on − − 10 ms

tsu(PO) power-on set-up-time note 1 25Cref(2) − − ms

Vi(FS)(rms) full-scale input voltage (RMS value) PGA gain = −3 dB − 1414(3) − mV

PGA gain = 0 dB − 1000 − mV

PGA gain = 3 dB − 708 − mV

PGA gain = 9 dB − 355 − mV

PGA gain = 15 dB − 178 − mV

PGA gain = 21 dB − 89 − mV

PGA gain = 27 dB − 44 − mV

Ci(PGA) input capacitance of the PGA − − 20 pF

(THD + N)/S total harmonic distortion plus noise-to-signal ratio

fs = 44.1 kHz at input signal of 1 kHz; PGA gain = 0 dB; note 4

Vi (0 dB) 1.0 V (RMS) − −85 −80 dB

− 0.0056 0.01 %

Vi (−60 dB) − −30 −20 dB

− 3.2 10.0 %

S/N signal to noise ratio Vi = 0.0 V 90 95 − dBA

αct crosstalk between channels PGA gain = 0 dB − 100 − dB

fs sample frequency (128fs) 0.640 − 7.04 MHz

OL digital output level PGA gain = 0 dB, Vi = 1 V (RMS)

− −2.0 − dBFS

Power-on reset · PGA and ADC

Page 43 of the Philips UDA1325 user manual — SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT
Page 43 · click to enlarge
Page 43

SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT

RES resolution 16 − − bits

Vo(FS)(rms) full-scale output voltage (RMS value)

VDD = 3.3 V − 0.66 − V

SVRR supply voltage ripple rejection at VDDA and VDDO

fripple = 1 kHz Vripple(p-p) = 0.1 V

− 60 − dB

∆Vo channel unbalance maximum volume − 0.03 − dB

αct crosstalk between channels RL = 5 kΩ − 95 − dB

(THD + N)/S total harmonic distortion plus noise-to-signal ratio

fs = 44.1 kHz; RL = 5 kΩ; note 5

at input signal of 1 kHz (0 dB) − −90 −80 dB

− 0.0032 0.01 %

at input signal of 1 kHz (−60 dB) − −30 −20 dB

− 3.2 10 %

S/N signal-to-noise ratio at bipolar zero A-weighting at code 0000H

90 95 − dB

1. Strongly depends on the external decoupling capacitor connected to V ref(DA) .
2. C ref in µ F.
3. Although a level of 1.414 V (RMS) would be required to optimal drive the ADC in this gain setting, this level can not be used. Due to the 3.3 V supply voltage input, signals of 1.17 V (RMS) and higher will result in clipping.
4. Measured with the APLL as ADC clock source.
5. Measured with I 2 S-bus input as digital source.

Filter stream DAC

Page 44 of the Philips UDA1325 user manual — APPLICATION INFORMATION
Page 44 · click to enlarge
Page 44

APPLICATION INFORMATION

Philips UDA1325 — APPLICATION INFORMATION diagram (page 44)
Fig. 2
Page 45 of the Philips UDA1325 user manual — APPLICATION INFORMATION
Page 45 · click to enlarge
Page 45
Philips UDA1325 — APPLICATION INFORMATION diagram (page 45)
Fig. 3
Page 46 of the Philips UDA1325 user manual — VUSB
Page 46 · click to enlarge
Page 46

white to force landscape pages to be rotated correctly when browsing through the pdf in the Acrobat reader. white to force landscape pages to be ...

This text is here in white to force landscape pages to be rotated correctly when browsing through the pdf in the Acrobat reader.This text is here in

_white to force landscape pages to be rotated correctly when browsing through the pdf in the Acrobat reader.This text is here inThis text is here in

MGS271

Philips UDA1325 — MGS271 diagram (page 46)
Fig. 4

16 GP0/BCKI

15 GP5/WSI

14 GP1/DI

3 BCK

2 WS

1 DA

8 D −

9 D +

36 VINR

34 VINL C22

47 µF (16 V)

47 µF (16 V)

18 pF (50 V)

R7

22 Ω

R16

22 Ω

1.5 kΩ

22 pF (63 V)

1.5 µH

18 pF (50 V)

R48

+ VC

10 nF (63 V)

12 pF (63 V)

12 pF (63 V)

22 pF (63 V)

BCKI

WSI

DI

BCK

WS

DA

ADC XTAL

10 nF (50 V)

VUSB

8 2 7 3 6 4 5

10 nF (50 V)

Show 15 more labels / short text on this page
(I2C-bus) · 21 XTAL2b · 20 XTAL1b · 40 XTAL2a · 41 XTAL1a · X1 48 MHz · recording · analog · input · playback · recording · digital · input · digital · input
Page 47 of the Philips UDA1325 user manual — PACKAGE OUTLINES
Page 47 · click to enlarge
Page 47

PACKAGE OUTLINES

SDIP42plastic shrink dual in-line package; 42 leads (600 mil) SOT270-1
Philips UDA1325 — PACKAGE OUTLINES diagram (page 47)
Fig. 5

UNIT b1 c E e MH L

1.3 0.8 0.53 0.40 0.32 0.23 38.9 38.4 14.0 13.7 3.2 2.9 0.18 1.778 15.24 15.80 15.24 17.15 15.90 1.73 5.08 0.51 4.0

Page 48 of the Philips UDA1325 user manual — SOT319-2
Page 48 · click to enlarge
Page 48

QFP64: plastic quad flat package; 64 leads (lead length 1.95 mm); body 14 x 20 x 2.8 mm SOT319-2

Philips UDA1325 — SOT319-2 diagram (page 48)
Fig. 6

UNIT A1 A2 A3 bp c E(1) e HE L Lp Z y w v θ

mm 0.25 0.05 2.90 2.65 0.25 0.50 0.35 0.25 0.14 14.1 13.9 1 18.2 17.6 1.2 0.8 7 0

Page 49 of the Philips UDA1325 user manual — R EFLOW SOLDERING
Page 49 · click to enlarge
Page 49

SOLDERING

Typical reflow peak temperatures range from 215 to 250 °C. The top-surface temperature of the packages should preferable be kept below 230 °C.

This text gives a very brief insight to a complex technology. A more in-depth account of soldering ICs can be found in our “Data Handbook IC26; Integrated Circuit Packages” (document order number 9398 652 90011).

W AVE SOLDERING

Conventional single wave soldering is not recommended for surface mount devices (SMDs) or printed-circuit boards with a high component density, as solder bridging and non-wetting can present major problems.

There is no soldering method that is ideal for all IC packages. Wave soldering is often preferred when through-hole and surface mount components are mixed on one printed-circuit board. However, wave soldering is not always suitable for surface mount ICs, or for printed-circuit boards with high population densities. In these situations reflow soldering is often used.

To overcome these problems the double-wave soldering method was specifically developed.

If wave soldering is used the following conditions must be observed for optimal results:

  • Use a double-wave soldering method comprising a turbulent wave with high upward pressure followed by a smooth laminar wave.

S OLDERING BY DIPPING OR BY SOLDER WAVE

  • For packages with leads on two sides and a pitch (e):

The maximum permissible temperature of the solder is 260 °C; solder at this temperature must not be in contact with the joints for more than 5 seconds. The total contact time of successive solder waves must not exceed 5 seconds.

– larger than or equal to 1.27 mm, the footprint

longitudinal axis is preferred to be parallel to the transport direction of the printed-circuit board;

– smaller than 1.27 mm, the footprint longitudinal axis

must be parallel to the transport direction of the printed-circuit board.

The device may be mounted up to the seating plane, but the temperature of the plastic body must not exceed the specified maximum storage temperature (Tstg(max)). If the printed-circuit board has been pre-heated, forced cooling may be necessary immediately after soldering to keep the temperature within the permissible limit.

The footprint must incorporate solder thieves at the downstream end.

  • For packages with leads on four sides, the footprint must be placed at a 45 ° angle to the transport direction of the printed-circuit board. The footprint must incorporate solder thieves downstream and at the side corners.

M ANUAL SOLDERING

Apply the soldering iron (24 V or less) to the lead(s) of the package, either below the seating plane or not more than 2 mm above it. If the temperature of the soldering iron bit is less than 300 °C it may remain in contact for up to 10 seconds. If the bit temperature is between 300 and 400 °C, contact may be up to 5 seconds.

During placement and before soldering, the package must be fixed with a droplet of adhesive. The adhesive can be applied by screen printing, pin transfer or syringe dispensing. The package can be soldered after the adhesive is cured.

Typical dwell time is 4 seconds at 250 °C. A mildly-activated flux will eliminate the need for removal of corrosive residues in most applications.

R EFLOW SOLDERING

M ANUAL SOLDERING

Reflow soldering requires solder paste (a suspension of fine solder particles, flux and binding agent) to be applied to the printed-circuit board by screen printing, stencilling or pressure-syringe dispensing before package placement.

Fix the component by first soldering two diagonally-opposite end leads. Use a low voltage (24 V or less) soldering iron applied to the flat part of the lead. Contact time must be limited to 10 seconds at up to 300 °C.

Several methods exist for reflowing; for example, infrared/convection heating in a conveyor type oven. Throughput times (preheating, soldering and cooling) vary between 100 and 200 seconds depending on heating method.

When using a dedicated tool, all other leads can be soldered in one operation within 2 to 5 seconds between 270 and 320 °C.

Introduction · Through-hole mount packages · Surface mount packages

Page 50 of the Philips UDA1325 user manual — SOLDERING METHOD
Page 50 · click to enlarge
Page 50

Suitability of IC packages for wave, reflow and dipping soldering methods

SOLDERING METHOD

MOUNTING PACKAGE

WAVE REFLOW (1) DIPPING

Through-hole mount DBS, DIP, HDIP, SDIP, SIL suitable(2) − suitable

Surface mount BGA, SQFP not suitable suitable −

HLQFP, HSQFP, HSOP, HTSSOP, SMS not suitable(3) suitable −

PLCC(4), SO, SOJ suitable suitable −

LQFP, QFP, TQFP not recommended(4)(5) suitable −

SSOP, TSSOP, VSO not recommended(6) suitable −

1. All surface mount (SMD) packages are moisture sensitive. Depending upon the moisture content, the maximum temperature (with respect to time) and body size of the package, there is a risk that internal or external package cracks may occur due to vaporization of the moisture in them (the so called popcorn effect). For details, refer to the Drypack information in the “Data Handbook IC26; Integrated Circuit Packages; Section: Packing Methods”.
2. For SDIP packages, the longitudinal axis must be parallel to the transport direction of the printed-circuit board.
3. These packages are not suitable for wave soldering as a solder joint between the printed-circuit board and heatsink (at bottom version) can not be achieved, and as solder may stick to the heatsink (on top version).
4. If wave soldering is considered, then the package must be placed at a 45 ° angle to the solder wave direction. The package footprint must incorporate solder thieves downstream and at the side corners.
5. Wave soldering is only suitable for LQFP, QFP and TQFP packages with a pitch (e) equal to or larger than 0.8 mm; it is definitely not suitable for packages with a pitch (e) equal to or smaller than 0.65 mm.
6. Wave soldering is only suitable for SSOP and TSSOP packages with a pitch (e) equal to or larger than 0.65 mm; it is definitely not suitable for packages with a pitch (e) equal to or smaller than 0.5 mm.
Page 51 of the Philips UDA1325 user manual — PURCHASE OF PHILIPS I 2 C COMPONENTS
Page 51 · click to enlarge
Page 51

DEFINITIONS

Objective specification This data sheet contains target or goal specifications for product development.

Preliminary specification This data sheet contains preliminary data; supplementary data may be published later.

Product specification This data sheet contains final product specifications.

Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability.

Where application information is given, it is advisory and does not form part of the specification.

LIFE SUPPORT APPLICATIONS

These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale.

PURCHASE OF PHILIPS I 2 C COMPONENTS

Purchase of Philips I2C components conveys a license under the Philips’ I2C patent to use the components in the I2C system provided the system conforms to the I2C specification defined by Philips. This specification can be ordered using the code 9398 393 40011.

Data sheet status · Limiting values · Application information

Page 52 of the Philips UDA1325 user manual — Philips Semiconductors – a worldwide company
Page 52 · click to enlarge
Page 52

Philips Semiconductors – a worldwide company

Argentina: see South America Australia: 34 Waterloo Road, NORTH RYDE, NSW 2113, Tel. +61 2 9805 4455, Fax. +61 2 9805 4466 Austria: Computerstr. 6, A-1101 WIEN, P.O. Box 213, Tel. +43 1 60 101 1248, Fax. +43 1 60 101 1210 Belarus: Hotel Minsk Business Center, Bld. 3, r. 1211, Volodarski Str. 6, 220050 MINSK, Tel. +375 172 20 0733, Fax. +375 172 20 0773 Belgium: see The Netherlands Brazil: see South America Bulgaria: Philips Bulgaria Ltd., Energoproject, 15th floor, 51 James Bourchier Blvd., 1407 SOFIA, Tel. +359 2 68 9211, Fax. +359 2 68 9102 Canada: PHILIPS SEMICONDUCTORS/COMPONENTS, Tel. +1 800 234 7381, Fax. +1 800 943 0087 China/Hong Kong: 501 Hong Kong Industrial Technology Centre, 72 Tat Chee Avenue, Kowloon Tong, HONG KONG, Tel. +852 2319 7888, Fax. +852 2319 7700 Colombia: see South America Czech Republic: see Austria Denmark: Sydhavnsgade 23, 1780 COPENHAGEN V, Tel. +45 33 29 3333, Fax. +45 33 29 3905 Finland: Sinikalliontie 3, FIN-02630 ESPOO, Tel. +358 9 615 800, Fax. +358 9 6158 0920 France: 51 Rue Carnot, BP317, 92156 SURESNES Cedex, Tel. +33 1 4099 6161, Fax. +33 1 4099 6427 Germany: Hammerbrookstraße 69, D-20097 HAMBURG, Tel. +49 40 2353 60, Fax. +49 40 2353 6300 Hungary: see Austria India: Philips INDIA Ltd, Band Box Building, 2nd floor, 254-D, Dr. Annie Besant Road, Worli, MUMBAI 400 025, Tel. +91 22 493 8541, Fax. +91 22 493 0966 Indonesia: PT Philips Development Corporation, Semiconductors Division, Gedung Philips, Jl. Buncit Raya Kav.99-100, JAKARTA 12510, Tel. +62 21 794 0040 ext. 2501, Fax. +62 21 794 0080 Ireland: Newstead, Clonskeagh, DUBLIN 14, Tel. +353 1 7640 000, Fax. +353 1 7640 200 Israel: RAPAC Electronics, 7 Kehilat Saloniki St, PO Box 18053, TEL AVIV 61180, Tel. +972 3 645 0444, Fax. +972 3 649 1007 Italy: PHILIPS SEMICONDUCTORS, Piazza IV Novembre 3, 20124 MILANO, Tel. +39 02 67 52 2531, Fax. +39 02 67 52 2557 Japan: Philips Bldg 13-37, Kohnan 2-chome, Minato-ku, TOKYO 108-8507, Tel. +81 3 3740 5130, Fax. +81 3 3740 5077 Korea: Philips House, 260-199 Itaewon-dong, Yongsan-ku, SEOUL, Tel. +82 2 709 1412, Fax. +82 2 709 1415 Malaysia: No. 76 Jalan Universiti, 46200 PETALING JAYA, SELANGOR, Tel. +60 3 750 5214, Fax. +60 3 757 4880 Mexico: 5900 Gateway East, Suite 200, EL PASO, TEXAS 79905, Tel. +9-5 800 234 7381, Fax +9-5 800 943 0087 Middle East: see Italy

Netherlands: Postbus 90050, 5600 PB EINDHOVEN, Bldg. VB, Tel. +31 40 27 82785, Fax. +31 40 27 88399 New Zealand: 2 Wagener Place, C.P.O. Box 1041, AUCKLAND, Tel. +64 9 849 4160, Fax. +64 9 849 7811 Norway: Box 1, Manglerud 0612, OSLO, Tel. +47 22 74 8000, Fax. +47 22 74 8341 Pakistan: see Singapore Philippines: Philips Semiconductors Philippines Inc., 106 Valero St. Salcedo Village, P.O. Box 2108 MCC, MAKATI, Metro MANILA, Tel. +63 2 816 6380, Fax. +63 2 817 3474 Poland: Ul. Lukiska 10, PL 04-123 WARSZAWA, Tel. +48 22 612 2831, Fax. +48 22 612 2327 Portugal: see Spain Romania: see Italy Russia: Philips Russia, Ul. Usatcheva 35A, 119048 MOSCOW, Tel. +7 095 755 6918, Fax. +7 095 755 6919 Singapore: Lorong 1, Toa Payoh, SINGAPORE 319762, Tel. +65 350 2538, Fax. +65 251 6500 Slovakia: see Austria Slovenia: see Italy South Africa: S.A. PHILIPS Pty Ltd., 195-215 Main Road Martindale, 2092 JOHANNESBURG, P.O. Box 58088 Newville 2114, Tel. +27 11 471 5401, Fax. +27 11 471 5398 South America: Al. Vicente Pinzon, 173, 6th floor, 04547-130 SÃO PAULO, SP, Brazil, Tel. +55 11 821 2333, Fax. +55 11 821 2382 Spain: Balmes 22, 08007 BARCELONA, Tel. +34 93 301 6312, Fax. +34 93 301 4107 Sweden: Kottbygatan 7, Akalla, S-16485 STOCKHOLM, Tel. +46 8 5985 2000, Fax. +46 8 5985 2745 Switzerland: Allmendstrasse 140, CH-8027 ZÜRICH, Tel. +41 1 488 2741 Fax. +41 1 488 3263 Taiwan: Philips Semiconductors, 6F, No. 96, Chien Kuo N. Rd., Sec. 1, TAIPEI, Taiwan Tel. +886 2 2134 2886, Fax. +886 2 2134 2874 Thailand: PHILIPS ELECTRONICS (THAILAND) Ltd., 209/2 Sanpavuth-Bangna Road Prakanong, BANGKOK 10260, Tel. +66 2 745 4090, Fax. +66 2 398 0793 Turkey: Yukari Dudullu, Org. San. Blg., 2.Cad. Nr. 28 81260 Umraniye, ISTANBUL, Tel. +90 216 522 1500, Fax. +90 216 522 1813 Ukraine: PHILIPS UKRAINE, 4 Patrice Lumumba str., Building B, Floor 7, 252042 KIEV, Tel. +380 44 264 2776, Fax. +380 44 268 0461 United Kingdom: Philips Semiconductors Ltd., 276 Bath Road, Hayes, MIDDLESEX UB3 5BX, Tel. +44 181 730 5000, Fax. +44 181 754 8421 United States: 811 East Arques Avenue, SUNNYVALE, CA 94088-3409, Tel. +1 800 234 7381, Fax. +1 800 943 0087 Uruguay: see South America Vietnam: see Singapore Yugoslavia: PHILIPS, Trg N. Pasica 5/v, 11000 BEOGRAD, Tel. +381 11 62 5344, Fax.+381 11 63 5777

For all other countries apply to: Philips Semiconductors, International Marketing & Sales Communications, Building BE-p, P.O. Box 218, 5600 MD EINDHOVEN, The Netherlands, Fax. +31 40 27 24825

Internethttp://www.semiconductors.philips.com

© Philips Electronics N.V. SCA

All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights.

Printed in The Netherlands 545002/750/01/pp52 Date of release: 1999 May 10 Document order number: 9397 750 02805

1999 64

Ask about the Philips UDA1325

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Philips UDA1325

Be the first to ask — other owners or our team will answer.

Original document

Philips UDA1325 manual PDF

52 pages·246 KB·Computer Drive·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…