Instruction for Use
A-Series Sensors M1191A M1191AL M1192A M1193A M1194A M1195A



philips



Three series of Philips reusable SpO2 sensors offer monitoring capability for a broad range of patient types as shown in the table below. Reference Specifications later in this IFU for sensor accuracy.
1These sensors have a Longer 3m (versus standard 2m) attached cable. 2These sensors extend compatibility to Philips brand OxiMax® compatible instruments. 3Preferred application sites for M1193A and M1195A sensors.

Intended Use Philips reusable SpO2 sensors are for multi-patient use, when continuous non-invasive arterial oxygen saturation and pulse rate monitoring are required.
Accessories Supplied with Sensors • M1627A Adult Wristband: Supplied only with adult finger sensors to secure sensor cable to back of adult patient’s hand and wrist.
Accessories Available for Separate Purchase • M1940A Adapter Cable: 8-pin (round female) to 12-pin (round male) adapter cable. Adapts 8-pin sensor connector to 12-pin instrument jack. Extends sensor cable length by 2m. DO NOT USE with M1191AL, M1191ANL, M1191BL sensors.



Be sure to read and understand all Warnings listed in your SpO2 monitoring instrument IFU, as well as all Warnings described in this sensor IFU. Use sensors only with validated Instruments and at a recommended patient application area.
Inspect Sensor for Damage • Inspect the sensor outside and inside. To check the inside, gently open the sensor cavity and check for splits on or next to the transparent silicone that covers the optical elements. Be sure there are no blisters on the silicone, and no liquid leaking from sensor optics.
Dispose Deteriorated Sensors Any sensor showing signs of physical or electrical deterioration or failure should be disinfected, decontaminated, and disposed of according to local laws regarding the disposal of hospital waste.
Move the sensor application site every 4 hours, or more often if circulation or skin integrity is compromised.


adult application · shown


The reusable sensors should be cleaned and disinfected, but never sterilized. Follow the procedure outlined below.
- Mild Detergent - Salt Solution (1%)
Metricide® 28 Cidex® Formula 7 Kohrsolin® (2%)
Metricide® Plus 30 Cidex® OPA Mucapur®-CD (1%)
Terralin® Liquid Cidex® Plus Isopropanol (70%) or Isopropanol Wipe (70%) Incidin® Liquid Omnicide® 28

Sensor Accuracy A-Series Sensors: For A-Series sensor SpO2 and Pulse Rate accuracy specifications, reference your Philips/Agilent/HP instrument’s Instructions for Use.
B-Series Sensors: SpO2 and Pulse Rate accuracy specifications for M1191B and M1191BL sensors are the same as indicated for M1191A and M1191AL sensors in your Philips/Agilent/HP instrument’s Instructions for Use.
Special Edition A-Series Sensors (AN-Series): SpO2 accuracy (functional saturation) for Special Edition A-Series sensors used in combination with M1020B or M3001A, Option A02, specified as the root-mean-square (RMS) difference between the measured values and the reference values, in the range 70 to 100% is: 2% for M1191ANL and M1192AN; 3% for M1193AN, M1194AN, and M1195AN.
Neonatal Applications: The claimed accuracy numbers for neonatal application are already increased by an additional 1% to account for affect on oximeter measurements due to fetal hemoglobin in neonatal blood, as predicted by the literature.
Light Emitting Diode Wavelength Ranges Wavelength ranges for the light emitting diodes used in these sensors are within 600nm-1000nm, with an optical output power of less than 15mW. Knowing the wavelength range can be useful to clinicians performing photodynamic therapy.
Measurement Validation The SpO2 accuracy has been validated in human studies against arterial blood sample reference measured with a CO-oximeter. In a controlled desaturation study, healthy adult volunteers with saturation levels between 70% and 100% SaO2 were studied. The population characteristics for those studies were: