Philips FMod-TCP BOX

58 pages·1.8 MB·Network Card·PDF·ENDEFRITNLJA
Philips FMod-TCP BOX
Table of Contents 7 sections Package and operating conditions · Overview · Quick start · Controlling the FMod-TCP BOX by TCP or UDP · … ShowHide
Page 1 of the Philips FMod-TCP BOX user manual — See page 10 for
Page 1 · click to enlarge
Page 1

See page 10 for

quick start

Ethernet Converter Device FMod-TCP BOX User Manual

Version 1.2

Philips FMod-TCP BOX — See page 10 for diagram (page 1)
Fig. 1 · See page 10 for
Philips FMod-TCP BOX — See page 10 for diagram (page 1)
Fig. 2 · See page 10 for
Page 2 of the Philips FMod-TCP BOX user manual — 2 / 58
Page 2 · click to enlarge
Page 2

2 / 58

Version: 1.2 Last revision: August 14th, 2006 Printed in Switzerland © Copyright 2003-2006 FiveCo Sàrl. All rights reserved. The contents of this manual may be modified by FiveCo without any warning.

Trademarks Windows® is a registered trademark of Microsoft Corporation. Ethernet® is a registered trademark of Xerox Corporation. Java® is a registered trademark of Sun Microsystem. Philips® is a registered trademark of Koninklijke Philips Electronics N.V. Borland® is a registered trademark of Borland Software Corporation. Warning This device is not intended to be used in medical, life-support or space products. Any failure of this device that may cause serious consequences should be prevented by implementation of backup systems. The user agrees that protection against consequences resulting from device system failure is the user's responsibility. Changes or modifications to this device not explicitly approved by FiveCo will void the user's authority to operate this device. Support Web page: http://www.fiveco.ch/section_motion/support_motion_E.htm e-mail: [email protected]

Page 4 of the Philips FMod-TCP BOX user manual — 4 / 58
Page 4 · click to enlarge
Page 4

4 / 58

RevisionDateAuthorNoteFirmware versionApplet versionWin32 app version 1.005.05.06AG- First versionSince 1.0Since 1.0Since 3.0 1.109.06.06AG- Update specifications - Text correctionsSince 1.0Since 1.0Since 3.0 1.214.08.06AG- I2C speed correction. - Warning register bits correction.Since 1.0Since 1.0Since 3.0
Page 5 of the Philips FMod-TCP BOX user manual — 3 A
Page 5 · click to enlarge
Page 5

5 / 58

1 Package and operating conditions

Starter Kit contents

The FMod-TCP BOX “Starter kit” should contain:

ƒ FMod-TCP BOX device ƒ RS232 DSub cable ƒ DIN 41651 40 lines cable ƒ CD-Rom with dedicated software and Java applet sample ƒ This manual

Absolute maximum rating

Damage may occur if the device is operated using values beyond those mentioned below; device operation is not guaranteed.

Parameter Conditions Min Typ Max Unit Supply voltage 0 24 33 V Supply current No device connected to extension connector.

Supply current Device(s) connected to extension connector.

Preliminary

3 A

Outputs 1, 2 current Relays. 1 A Outputs 1, 2 voltage Max voltage to GND. 50 V Outputs 3-14 current 0.5 A Outputs 15, 16 current 1 A Inputs voltage -15 28 V +5V output current Pin 17 on extension connector. 0.4 A Power output current Pin 40 on extension connector. 1 A Operating temperature 0 70 °C Storage temperature -40 120 °C All external pins are protected against destruction by ESD (2kV). The power supply input is protected against over and inverted voltage by a 33V Zener diode. The protection is guaranteed during 10ms within the following current values:

ƒ For inverted voltage: 100A (the internal polifuse will cut the supply). ƒ For over voltage: 3.25A max (the diode will be destroyed before the

fuse after 10ms!). Damages to the device due to over or inverted voltage are not covered by the warranty.

60 100 mA

Page 6 of the Philips FMod-TCP BOX user manual — Software operating principle
Page 6 · click to enlarge
Page 6

6 / 58

2 Overview

Applications

QtyTypeDescriptionPort 1RS232Up to 115200 bps with or without hardware flow controlTCP 8000 2RelaysCut up to 50V 1ATCP 8010 UDP 7010 1424V OutputsHigh side drivers 1624V InputsDigital 24V inputs or analog ±12 V 10 bits A/D 1I2C bus2 wires bus serial bus

Software operating principle

The operating principle for PC softwares that must exchange data with an FMod-TCP BOX device depends on which interface is used. In case of RS232 use, the operation is really simple. Any byte sent to port TCP #8000 will be redirected to the serial bus and any byte received from the serial bus will be redirected to the TCP connection. In the other cases (I/O, A/D and I2C), the software has to use a dedicated protocol layer on top of the TCP Layer (see chapter 4). This protocol is

Page 7 of the Philips FMod-TCP BOX user manual — Front view
Page 7 · click to enlarge
Page 7

7 / 58

"Question & Answer" oriented. The PC should send a Question, wait for the Answer and so on. To configure the device's parameters and to access I/O and A/D features, the protocol uses an Internal Registers Access routine (see chapter 4 and 7). The code samples available on the FiveCo's web site can help programmers get started with development.

Hardware description

Philips FMod-TCP BOX — Hardware description diagram (page 7)
Fig. 3 · Hardware description

12 – 32 VDC

Inputs, Outputs, I2C bus, Supply voltage, 5V and GND

Ethernet connector SOS button

Beware: Before connecting any cable to the device, shut down power supply!

Front view

Philips FMod-TCP BOX — Front view diagram (page 7)
Fig. 4 · Front view

RJ45 Ethernet connector SOS button

Power connector · RS232 connector · Dimensions in mm

Page 8 of the Philips FMod-TCP BOX user manual — A
Page 8 · click to enlarge
Page 8

8 / 58

GreenEverything is normal. RedThere is an error. See Warning register to know the source of the error. Red-Green blinkingThe device found another one with the same IP address on the network. Disable the other device and reboo t the FMod-TCP BOX.
Philips FMod-TCP BOX — 8 / 58 diagram (page 8)
Fig. 5

Left side

Philips FMod-TCP BOX — Left side diagram (page 8)
Fig. 6 · Left side

12 – 32 VDC

1Input 121Output 16 2Input 222Output 15 3Input 323Output 14 4Input 424Output 13 5Input 525Output 12 6Input 626Output 11 7Input 727Output 10 8Input 828Output 9 9Input 929Output 8 10Input 1030Output 7 11Input 1131Output 6 12Input 1232Output 5 13Input 1333Output 4 14Input 1434Output 3 15Input 1535Output 2 B (relay 2) 16Input 1636Output 2 A (relay 2) 17+5V37Output 1 B (relay 1) 18GND38Output 1 A (relay 1) 19I2C clock (SCL)39Supply GND 20I2C data (SDA)40Supply voltage (max 1A) a

aDo not supply the device throu s r connector.

gh thi pin. Use powe

Here are the equivalent electrical specif s of I/O pins (illustra black dots):

Inputs Outputs 3-16 Outputs 1-2

Preliminary

A

B

Show 6 more labels / short text on this page
1st pin · Power connector · ication ted by · Vpower · ~47kΩ · 2mA
Page 9 of the Philips FMod-TCP BOX user manual — SOS button
Page 9 · click to enlarge
Page 9

9 / 58

The I2C pins are provided through a Philips PCA9512 driver chip. 10kΩ pull

-ups are connected to A.

Rig

ht side

Standard RS232 DSub 9 connector

1NC6NC 2Receive data7Request To Send 3Transmit data8Clear To Send 4NC9NC 5GND

(male like on a computer)

The RS232 connector is the same as the ones found on any computer.

SOS button

A button is dedicated to restore default IP address or factory settings. There are tow possible scenarios:

ƒ If you press it while the device is running, the IP address will be

r l TC tions a have to send the Save Settings command to the device in order to save it into EEPROM.

estored as soon as al P connec re closed. Warning: you

and factory settings of all parameters will be restored AND saved into EEPROM. In this case, you do not need to send the Save Parameters command.

ƒ If the button is pressed during startup, the default IP address

SCL and SD

Page 10 of the Philips FMod-TCP BOX user manual — Changing IP address
Page 10 · click to enlarge
Page 10

10 / 58

3 Quick start

This section is intended to help users to quickly plug the module into their system and establish a connection between the computer and the device. You can find the device’s factory communication settings on the following label.

FMOD-TCP BOX INPUT(supply)5-32V DC, max 3A MAC: 00-50-C2-30-xx-xx / IP : 169.254.5.5

This device is not intended to be used in a medical, life-support or space product. Any failure of this device that may cause serious consequences should be prevented by implementation of backup systems. The user agrees that protection against consequences resulting from device system failure is the user's responsibility. [email protected] / www.fiveco.ch

The Ethernet MAC Address is fixed and cannot be changed. The IP Address can be changed. The complete procedure is described below. Note: If the device has already been configured and the IP address has been changed to an unknown value, you can retrieve an SOS IP address (the one on label) by pressing the “SOS button” during the normal operation of the device. (See section Erreur ! Source du renvoi introuvable.).

Changing IP address

To easily change the factory IP address, use the Win32 software provided on the CD-Rom.

1. Plug your new device on your PC network. 2. Start the Win32 application. 3. Click on "File->Easy change IP address". 4. The software will scan the network and display a list of all FiveCo's devices found. 5. Select the MAC address corresponding to your new device. 6. If you have more than one network adapter on your PC, the software will ask you to select the one which is connected to the same network as the FMod-TCP BOX. 7. The software will suggest a new IP address with the last byte left open. Choose a new IP (Not already used on your network!!) and click the "Change IP address" button. That’s it! The device has a new address and a new subnet mask (the same as your PC). They are automatically saved into EEPROM.

Page 11 of the Philips FMod-TCP BOX user manual — 11 / 58
Page 11 · click to enlarge
Page 11

11 / 58

You can now connect the device with the Win32 software or open its web page by typing its new IP address into a web browser. Notes:

ƒ The IP address won't be changed if a TCP connection exists with the

device. ƒ The protocol used to change the IP address is described later in this

manual.

Page 12 of the Philips FMod-TCP BOX user manual — RS232 (TCP # 8000 )
Page 12 · click to enlarge
Page 12

12 / 58

4 Controlling the FMod-TCP BOX by TCP or UDP

General Information

All the device's parameters (configuration registers) and features can be accessed through a TCP or UDP port. In addition, an HTTP-TCP port is available for web pages downloading and another TCP port for RS232 bus access. Those ports are:

ƒ TCP Port #80 for HTTP communication. ƒ TCP Port #8000 for RS232 transceiver. ƒ TCP Port #8010 to access I/O registers (see chapter 7) and I2C bus. ƒ UDP Port #7010 to access I/O registers (see chapter 7) and I2C bus. With regards to TCP connections, the device allows up to 4 simultaneous connections. These ports are described below.

RS232 (TCP # 8000 )

The RS232 bus of the microcontroller is accessible through the TCP port number 8000. The module acts simply as a transceiver for this port. Any byte sent from the network (ex: TCP-IP from a PC) to the module will be sent to the other side’s RS232 bus, and vice versa. Thus there is no particular protocol dedicated to this feature. See later chapters to know how to change parameters such as baud rate and hardware flow control. Note: This port supports only one user at a time. RS232 fixed settings: No parity / 1 Start Bit / 8 Data Bits / 1 Stop Bit Important note about baud rate greater than 9600bds: Common TCP/IP stacks (on PC, Unix station …) use a delay of 200ms for the acknowledgement of the TCP received data packets. This is done to reduce traffic on the network because TCP allows the acknowledgement of several packets at one time. Unfortunately, the FMod-TCP BOX device needs this acknowledgement to remove the data from its internal RS232 receive buffer (if no acknowledge is received from the PC, the module will resend those data).

Page 13 of the Philips FMod-TCP BOX user manual — 13 / 58
Page 13 · click to enlarge
Page 13

13 / 58

So, with speeds greater than 9600bds, the buffer may be filled faster than data can be sent by TCP and part of those will be lost if no RS232 hardware flow control is used between the FMod-TCP BOX and the RS232 device (CTS and RTS lines). If you cannot use hardware flow control on RS232 bus and you have to get more than 2048 bytes at one time, the solution is to reduce the TCP acknowledgement delay on your computer. For WindowsTM 2000/XP users, you can add/change the following value in the registry. BEWARE: improperly changes done in the Windows registry can results in a system crash! Such changes are the user’s full responsibility!

Entry: HKey_Local_Machine\SYSTEM\CurrentControlSet\Services\ Tcpip\Parameters\Interfaces\Interface-name Key: TcpDelAckTicks Value: DWORD with value 0x00 The interface-name is the registry name (32 digits number) of your Ethernet card which you use to access the module. The following web page describes this feature in details: http://www.microsoft.com/resources/documentation/Windows/2000/server/reskit/en- us/regentry/58801.asp?frame=true

Device parameters and I/O, A/D and I2C features (TCP # 8010 or UDP # 7010)

The main TCP port number 8010 or UDP port number 7010 can be used to change some important parameters of the module:

ƒ TCP timeout value ƒ IP address ƒ Subnet mask ƒ Module name ƒ Baud rate and flow control ƒ I2C speed The user should use the Win32 application enclosed in the package or the default java applet loaded in the module to change those parameters. If the user wants to change the parameters by himself, the protocol is defined below. This port is also used to access Inputs and Outputs value, A/D conversion result registers (see page 34 for a complete description of those registers) and I2C bus. The I2C feature is described after “registers access feature”. The last feature accessible through this port is the "Easy IP config" that is used in the "Quick start" chapter of this document.

Page 14 of the Philips FMod-TCP BOX user manual — Registers access feature
Page 14 · click to enlarge
Page 14

14 / 58

Registers access feature

TCP/IP works in big endian: most significant byte first, followed by least significant byte. The access to the data is done through an easy (6 byte header) protocol over TCP. Structure of each packet:

1. Function ID (2 bytes), 2. Transaction ID (2 bytes) 3. Length of the parameters (2 bytes) 4. Parameters (X byte) 5. Checksum (2 bytes) (described later in this chapter) The user (sender) defines the values of the Transaction IDs himself. The module that receives a command sends back an answer (for every command). The answer contains the same Transaction ID as the corresponding command sent. The user is also able to check execution of each command. Read register(s) command:
Philips FMod-TCP BOX — Registers access feature diagram (page 14)
Fig. 7 · Registers access feature

Byte# Number of bits Example 0x00 Read (0x0021) 16 bits 0x0021 0x02 TransactionID 16 bits 0x1B34 0x04 Number of registers to read (X)

0x06 X * Registers Addresses X * 8 bits 0x02 0x06+X Checksum 16 bits 0x…

The maximum number of registers that can be read at one time is almost 30. The answer sequence should not be greater than 180 bytes. If the number of registers is too big, the FMod-TCP BOX will answer only with the value of some of them. The module answers with the following sequence:

Philips FMod-TCP BOX — Registers access feature diagram (page 14)
Fig. 8 · Registers access feature

Byte# Number of bits Example 0x00 Read Answer (0x0023) 16 bits 0x0023 0x02 TransactionID (same as demand)

0x04 Number of bytes in answer 16 bits 0x0019 0x06 Register address 8 bits 0x02 … Register value 8—128 bits (16B) 0x12345

The two previous entries are replicated for every register that has been asked for reading

… Checksum 16 bits 0x…

Page 15 of the Philips FMod-TCP BOX user manual — I2C feature
Page 15 · click to enlarge
Page 15

15 / 58

Write register(s) command:

Philips FMod-TCP BOX — 15 / 58 diagram (page 15)
Fig. 9

Byte# Number of bits Example 0x00 Write (0x0022) 16 bits 0x0022 0x02 TransactionID 16 bits 0x1B34 0x04 Number of bytes in command

0x06 Register Addresses 8 bits 0x02 0x07 Register value 8 — 64 bits 0x1234

The two previous entries are replicated for every register that has been asked for reading

The max length of this sequence is 180 bytes. The module answers with the following sequence:

Philips FMod-TCP BOX — 15 / 58 diagram (page 15)
Fig. 10

Byte# Number of bits Example 0x00 Write Answer (0x0024) 16 bits 0x0024 0x02 TransactionID (same as demand)

0x04 0x0000 16 bits 0x0000 0x06 Checksum 16 bits 0x…

I2C feature

The Inter-IC bus, commonly known as the I²C bus, is a control bus that provides the communications link between integrated circuits in a system. Developed by Philips in the early 1980’s, this simple two-wire bus has become the de facto worldwide standard for system control, finding its way into everything from temperature sensors and voltage level translators to EEPROMs, general-purpose I/O, A/D and D/A converters, CODECs, and microprocessors of all kinds. You can find the I2C’s specifications on the Philips web site at the following link: http://www.semiconductors.philips.com/ The I2C protocol can access a device by three different manners:

ƒ Write (Start, AddW, Byte1, Byte2, …, Stop)

St AddW A Bytes to W A Sp ƒ Read (Start, AddR, Byte1, Byte2, …, Stop)

St AddR A Bytes to R nA Sp ƒ Read After Write (Start, AddW, ByteW1, ByteW2, …, ReStart,

AddR, ByteR1, ByteR2, …Stop)

St AddW A Bytes to W R A AddR A Bytes to R nA Sp

Page 16 of the Philips FMod-TCP BOX user manual — 16 / 58
Page 16 · click to enlarge
Page 16

16 / 58

To be able to do all of these 3 sequences, use this command:

Byte# Number of bits Example 0x00 I2CRWwithAck (0x0007) 16 bits 0x0007 0x02 TransactionID 16 bits 0x1B34 0x04 LengthOfParameters (X + 3) 16 bits 0x0005 0x06 7 bits Address (bit 7 = 0) 8 bits 0x28 0x07 X (number of bytes to write) 8 bits 0x02 0x08 xBytes X bytes 0xAF1D …. Y (number of bytes to read) 8 bits 0x05 The four previous entries can be replicated to access the same or other I2C slaves within this command sequence. Checksum 16 bits 0x… If X = 0, the Read method is used. If Y = 0, the Write method is used. If X & Y ≠ 0, the Read after Write method is used. The answer sequence is the following one:

Philips FMod-TCP BOX — 16 / 58 diagram (page 16)
Fig. 11

Byte# Number of bits Example 0x00 I2CReadAnswer (0x0008) 16 bits 0x0008 0x02 TransactionID (same as demand)

0x04 Number of bytes in answer 16 bits 0x0005 0x06 Answer bytes Y bytes 0x1A25… … Ack state of the I2C com. 1 byte 0x87 If the same or other I2C slave have been accessed in the command, the answer bytes and ack state is added here. … Checksum 16 bits 0x… The "Ack state" byte is composed of the following bits:

0 Address ack in write sequence 0 = No answer to this address 1 = ack received 1 Bytes written ack (each byte was acked) 0 = Bytes not acknowledged 1 = ack received 2 Address ack in read sequence 0 = No answer to this address 1 = ack received 3-6 Reserved - 7 Must be always 1 1 The user can use these bits to check for the presence of his I2C devices and monitor hardware issues.

Philips FMod-TCP BOX — 16 / 58 diagram (page 16)
Fig. 12
Page 17 of the Philips FMod-TCP BOX user manual — I2C speed change (advanced features)
Page 17 · click to enlarge
Page 17

17 / 58

Note that the max length of those sequences is 180 bytes. Pay close attention to building sequences that do not exceed this and not to ask too much byte in answer ! The FMod-TCP BOX translates automatically those sequences to I2C sequences. It is mandatory that the sequence has to be transmitted within one TCP packet. Otherwise, the FMod-TCP BOX will ignore it.

I2C Bus scanning

The following command allows user to ask an I2C bus scanning to list which addresses answer with an acknowledge. I2C scan command:

Byte# Number of bits Example 0x00 I2CScan (0x0005) 16 bits 0x0005 0x02 TransactionID 16 bits 0x2001 0x04 Number of addresses to scan 16 bits 0x0001 0x08 X Addresses X bytes 0x1A Checksum 16 bits 0x… The FMod-TCP BOX answers with the following sequence:

Philips FMod-TCP BOX — I2C Bus scanning diagram (page 17)
Fig. 13 · I2C Bus scanning
Philips FMod-TCP BOX — I2C Bus scanning diagram (page 17)
Fig. 14 · I2C Bus scanning

Byte# Number of bits Example 0x00 I2CScanAnswer (0x0006) 16 bits 0x0006 0x02 TransactionID (same as demand)

0x04 Number of valid addresses 16 bits 0x0001 0x06 Valid addresses list n bytes 0x1A Checksum 16 bits 0x… Note: If there is no address in the I2C Scan command, the FMod-TCP BOX will scan all addresses between 1 and 127!

I2C speed change (advanced features)

The I2C bus speed can be changed at any time by changing the content of the I2CSPD parameter. Beware:

1. Do not change I2C speed if it is not mandatory. Speed greater than 100kHz are not supported by all I2C slaves. 2. Do not change I2C speed during I2C communication.
Page 18 of the Philips FMod-TCP BOX user manual — 18 / 58
Page 18 · click to enlarge
Page 18

18 / 58

3. The I2C controller does not match all I2C specifications at speed higher than 100kHz. This feature will therefore not work with all I2C slaves. The value of the I2CSPD parameter must be computed with the following formula:

1 2 10 2

wanted CSpeed I CSPD I

The I2C speed cannot be saved in EEPROM.

7 − =

Page 19 of the Philips FMod-TCP BOX user manual — Easy IP address config (UDP # 7010)
Page 19 · click to enlarge
Page 19

19 / 58

Easy IP address config (UDP # 7010)

A really useful feature of the UDP port #7010 is the "Easy IP config" one. The user who wants to design his own software can use this feature to do a "quick start/install" method. Indeed, since this protocol uses a broadcast UDP packet, even if the device is not in the same subnet, it should receive its new IP address and subnet mask. Procedure: Send a UDP broadcast message (using a local or direct broadcast IP address) to your network (inside which the FMod-TCP BOX is connected) with the following command:

Philips FMod-TCP BOX — Easy IP address config (UDP # 7010) diagram (page 19)
Fig. 15 · Easy IP address config (UDP # 7010)

Byte# Number of bits Example 0x00 Change IP fct (0x002A) 16 bits 0x002A 0x02 TransactionID 16 bits 0x0000 0x04 Length of params (0x000E) 16 bits 0x000E 0x06 FMod-TCP BOX Mac Address 6 bytes 0x0050C2308101 0x0C FMod-TCP BOX new IP Address

0x14 Checksum 16 bits 0x… If the FMod-TCP BOX recognizes its MAC address, it will answer this command with a simple acknowledges and change its IP address and subnet mask IF NO TCP CONNECTION IS MADE TO THE DEVICE.

Byte# Number of bits Example 0x00 Change IP fct ack (0x002B) 16 bits 0x002B 0x02 TransactionID 16 bits 0x0000 0x04 Length of params (0x0000) 16 bits 0x0000 0x14 Checksum 16 bits 0x…

Philips FMod-TCP BOX — Easy IP address config (UDP # 7010) diagram (page 19)
Fig. 16 · Easy IP address config (UDP # 7010)
Page 20 of the Philips FMod-TCP BOX user manual — Checksum calculation
Page 20 · click to enlarge
Page 20

20 / 58

Checksum calculation

This checksum is the same as the IP checksum. Definition: sum of 1’s complement of all 16 bits words of whole message (FiveCo packet) except checksum bytes. Note: all values are unsigned! Sequence: 1. Clear accumulator Loop x. Only if last word is not made of two bytes, the data byte is the upper byte (big endian) 2. Compute 1’s complement of each 16bits word, result is 16bits 3. Convert last result from 16 bits to 32 bits, result is 32bits: 0x0000+last result 4. Add last result to the 32 bits accumulator Try the Loop 5. Convert accumulator in two 16bits words 6. Add those two 16bits words, result is 16bits word. 7. If an overflow occurs with the last addition (Carry), add 1 to the last result. 8. Last result is the final result Example (in hexadecimal): !0x0021 (0XFFDE) Æ 0x0000FFDE (Read) +!0x1234 (0xEDCB) Æ 0x0001EDA9 (TransID) +!0x0003 (0xFFFC) Æ 0x0002EDA5 (3 reg to read) +!0x0A10 (0XF5EF) Æ 0x0003E394 (reg 0A,10,02) +!0x02(00)(0XFDFF) Æ 0x0004E193 Note that in this case a last 00 is implicitly used. (02 Æ 02 00).

0x0004 + 0xE193 = 0xE197, (carry=0) 0

xE197 + carry = 0xE197

Checksum = 0xE197

Page 21 of the Philips FMod-TCP BOX user manual — 21 / 58
Page 21 · click to enlarge
Page 21

21 / 58

Here is an example of a checksum calculation function in C: int RetCheckSum(Byte* ByteTab, int Size) { // This function returns the calculated checksum unsigned int Sum=0; bool AddHighByte=true; unsigned int ChecksumCalculated; for(int i=0;i>16)&0xFFFF)

+(ChecksumCalculated&0xFFFF); return ChecksumCalculated; } This function needs a Byte array (ByteTab) containing the command sequence and this array’s length (Size) as input, it returns the checksum as an int.

Page 22 of the Philips FMod-TCP BOX user manual — Overview
Page 22 · click to enlarge
Page 22

22 / 58

5 Java Applet

A specific Java Applet is provided with the module to control any of its ports without having to write any specific code.

Overview

To connect to the http server on the device, simply open your web browser and type the IP address of the module. Example with default address: “http://169.254.5.5” The applet is downloaded from the device to your computer and runs as a local process (on your computer). You need to use an internet web browser that is compatible with Java 1.1. Please note that on an MSWindowsTM based computer, a few seconds delay can occur when you download the applet due to an MSWindowsTM NetBios issue. The navigation through the four panels of the applet is done through the menu bar:

Philips FMod-TCP BOX — Overview diagram (page 22)
Fig. 17 · Overview
Page 23 of the Philips FMod-TCP BOX user manual — Main Config
Page 23 · click to enlarge
Page 23

23 / 58

Main Config

  • The Main panel shows the general information related to the device.
  • The first part allows the user to change the main settings of the device. Don't forget to use the "Save user parameters" button to make changes permanent!
  • The second part allows the user to save/restore user and factory parameters and to read the actual configuration of the device if it has been modified by another application.
Philips FMod-TCP BOX — Main Config diagram (page 23)
Fig. 18 · Main Config
Page 24 of the Philips FMod-TCP BOX user manual — Test A/D and I/Os
Page 24 · click to enlarge
Page 24

24 / 58

Test A/D and I/Os

This page can be used to access Inputs state and voltage and change Outputs state. The Inputs state and voltage are regularly updated automatically (20 kHz). You can change the low to high threshold of the inputs between 0 and 24V. This page display also the device supply voltage and warnings (Too low/high supply voltage, Outputs driver over current or temperature).

Philips FMod-TCP BOX — Test A/D and I/Os diagram (page 24)
Fig. 19 · Test A/D and I/Os
Page 25 of the Philips FMod-TCP BOX user manual — Test RS232
Page 25 · click to enlarge
Page 25

25 / 58

Test RS232

This page can be used to access RS232 bus. If you click on the "Connect to RS232 TCP Port" you can send ASCII data to RS232 bus and receive data from it (only ASCII is visible in this application).

Philips FMod-TCP BOX — Test RS232 diagram (page 25)
Fig. 20 · Test RS232

You can check "Add LF", "Add CR" and/or "Add Null" boxes to add a Line Feed, a Carriage Return and/or a Null Byte at the end of the ASCII chain sent to the device.

Page 26 of the Philips FMod-TCP BOX user manual — Test I2C
Page 26 · click to enlarge
Page 26

26 / 58

Test I2C

This page can be used to access I2C bus. The panel is divided in two parts:

ƒ The part on the right allows scanning the I2C bus to find available

slave devices. ƒ The part on the left allows sending a read or a write command to a

device on the I2C bus.

Philips FMod-TCP BOX — Test I2C diagram (page 26)
Fig. 21 · Test I2C

You should first check if you want a read or a write. Then you have to write hex data to write to the device in the "Hex data to write" field (if you

Page 27 of the Philips FMod-TCP BOX user manual — 27 / 58
Page 27 · click to enlarge
Page 27

27 / 58

checked the "Read" box, the FMod-TCP BOX will use the read after write I2C feature). After writing the I2C address (7bits hexa) and the number of bytes to read (if applicable), click on the "Send" button. The answer is displayed in hex in the "Data received" field.

Page 28 of the Philips FMod-TCP BOX user manual — Overview
Page 28 · click to enlarge
Page 28

28 / 58

6 Win32 Application

A specific application is provided with the module to control any of its ports without having to write a specific code.

Overview

Philips FMod-TCP BOX — Overview diagram (page 28)
Fig. 22 · Overview

IP address of the module Open or close TCP port

To open a TCP port on the module, the user has to set the correct IP address of the module, to choose the correct TCP port in the list and to click on the "Open" button. To close the port, simply click on the "Close" button. The status bar displays the status of the connection:

ƒ Connected ƒ Disconnected ƒ Error of connection (if connection was not established within 30s) Note: If you forgot the IP address of the module, you can use the "Scan network" feature of the "Connection" menu.

Show 4 more labels / short text on this page
TCP port number · Depends on port · Connection · status
Page 29 of the Philips FMod-TCP BOX user manual — 29 / 58
Page 29 · click to enlarge
Page 29

29 / 58

Philips FMod-TCP BOX — 29 / 58 diagram (page 29)
Fig. 23

This application uses the IP address of your computer and its subnet mask to find the scan broadcast address. When you click on scan, a broadcast message will be sent to all devices in your subnet and answers will be listed. WARNING: it only works with devices in your subnet! How does it work? When you click "Scan", the software simply sends a "Read registers" command to a broadcast address on UDP port number 7010 (see chapter about main port at page 13). The broadcast address depends on the network subnet mask present on your PC.

Page 30 of the Philips FMod-TCP BOX user manual — RS232 interface
Page 30 · click to enlarge
Page 30

30 / 58

RS232 interface

Philips FMod-TCP BOX — RS232 interface diagram (page 30)
Fig. 24 · RS232 interface

chain to send Send ASCII, Hex, or Decimal chain

Bytes received from RS232

The RS232 interface is easy to use. Just write the ASCII, HEX or decimal string in the dedicated text box and click corresponding "Send" button. The received bytes are displayed into the "Data received" boxes (same data but different representation).

Page 31 of the Philips FMod-TCP BOX user manual — “Load web files” interface
Page 31 · click to enlarge
Page 31

31 / 58

“Load web files” interface

Philips FMod-TCP BOX — “Load web files” interface diagram (page 31)
Fig. 25 · “Load web files” interface

File(s) list operations List of files to load

Number of bytes in list

Create file for factory upload

Load files into module

This option allows users to load their personal web files (html, java, jpeg, gif, txt …) into the flash memory. A maximum of 44kB is available for that application. An example of pages and Default Java Applet code is available on the Starter Kit CDRom or on the FiveCo's web page. For factory web upload, the user can save a single file yourname.web. See FMod-TCP BOX_WebPageUploading manual on the FiveCo web site.

Page 32 of the Philips FMod-TCP BOX user manual — Main port interface
Page 32 · click to enlarge
Page 32

32 / 58

Main port interface

Philips FMod-TCP BOX — Main port interface diagram (page 32)
Fig. 26 · Main port interface

Change RS232 baud rate Outputs state and flow control

Inputs state and voltage Change IP address of the module

Change subnet mask of the module Scan I2C bus

Number of bytes to read from I2C

Change module name Hex data to write to

Bytes received from I2C I2C operation

I2C Address The configuration interface allows the user to change the device’s settings. RS232 baud rate: The user can change the RS232 baud rate and enable or

disable the hardware flow control (CTS/RTS). TCP timeout: The user can change the number of seconds allowed before TCP port is disconnected. This feature avoids the problems due to the crash of a TCP client (PC). IP address: The user can change the IP address of the module. Subnet mask: The user can change the subnet mask of the module. MAC address: Mac address of the module (cannot be changed). Name: Module name. The Inputs state and voltage are simply obtained with a click on the corresponding “Read” button. The Outputs state and the analog threshold are send to the device with a click on the corresponding "Write" button.

Change disconnection timeout · Module MAC address

Page 33 of the Philips FMod-TCP BOX user manual — 33 / 58
Page 33 · click to enlarge
Page 33

33 / 58

The I2C interface is an easy way to test the I2C connection between the module and the user's electronic. The user has to choose between an I2C Read or Write operation. In Write mode, the bytes (in hexadecimal like 41 42 45 separated by spaces!) must be written in the dedicated line and the I2C address in the dedicated Address space (in hexadecimal or in decimal). Then click "Send". In Read mode, the steps are the same except that the user must specify how many bytes have to be read. Data to write is optional (only used for ReadAfterWrite I2C method).

Page 34 of the Philips FMod-TCP BOX user manual — RAM RUNNING
Page 34 · click to enlarge
Page 34

34 / 58

7 Registers management

Memory Organization

The user must know that a new register value sent through the communication port is loaded to the running parameters in RAM and used for the current process. All these parameters are lost upon power-down. It is required to save them to “User Parameters” or “Factory Parameters” with the corresponding function.

NON VOLATILE DATA.

EEPROM EEPROM ROM USER Parameters

5 1 2 3 4

VOLATILE DATA.

RAM RUNNING

WRITE

READ

PROCESSES

(TCP/UDP) [Web page or Software]

Action Number and description: 1 SaveUserParameters (0x03) function During standard power-up or calling 2 RestoreUserParameters (0x04) function 3 RestoreFactoryParameters (0x05) function SaveFactoryParameters (0x06) function + 1 4 [For integrators engineers only] 5 By setting “SOS Jumper” after power-up 3 5 + + 1 By setting “SOS Jumper” during power-up

Show 6 more labels / short text on this page
FACTORY Parameters · SOS IP address · Saved · Saved · Parameters · Communication port
Page 35 of the Philips FMod-TCP BOX user manual — Full Register Description
Page 35 · click to enlarge
Page 35

35 / 58

Full Register Description

List of registers

Address Bytes Name General Information

0x00 (00) 4 TYPE 0x01 (01) 4 VERSION 0x02 (02) 0 (fct) RESETCPU 0x03 (03) 0 (fct) SAVEUSERPARAMETERS 0x04 (04) 0 (fct) RESTOREUSERPARAMETERS 0x05 (05) 0 (fct) RESTOREFACTORYPARAMETERS 0x06 (06) 0 (fct) SAVEFACTORYPARAMETERS 0x07 (07) 4 VOLTAGE 0x08 (08) 4 WARNINGS Communication

0x10 (16) 4 COMOPTIONS 0x11 (17) 6 ETHERNETMAC 0x12 (18) 4 IPADDRESS 0x13 (19) 4 SUBNETMASK 0x14 (20) 1 TCPTIMEOUT 0x15 (21) 16 MODULENAME 0x16 (22) 1 RS232CONFIG 0x18 (24) 1 I2CSPD 0x1A (26) 1 TCPCONNECTIONSOPENED I/Os and AD

0x20 (32) 4 ANALOGINPUTSTHRESHOLD 0x21 (33) 2 OUTPUTS 0x23 (35) 2 INPUTS Analog voltage at inputs

0x30 (48) 4 INPUTVOLTAGE0VALUE 0x31 (49) 4 INPUTVOLTAGE1VALUE 0x32 (50) 4 INPUTVOLTAGE2VALUE 0x33 (51) 4 INPUTVOLTAGE3VALUE 0x34 (52) 4 INPUTVOLTAGE4VALUE 0x35 (53) 4 INPUTVOLTAGE5VALUE 0x36 (54) 4 INPUTVOLTAGE6VALUE 0x37 (55) 4 INPUTVOLTAGE7VALUE 0x38 (56) 4 INPUTVOLTAGE8VALUE 0x39 (57) 4 INPUTVOLTAGE9VALUE 0x3A (58) 4 INPUTVOLTAGE10VALUE 0x3B (59) 4 INPUTVOLTAGE11VALUE 0x3C (60) 4 INPUTVOLTAGE12VALUE 0x3D (61) 4 INPUTVOLTAGE13VALUE 0x3E (62) 4 INPUTVOLTAGE14VALUE 0x3F (63) 4 INPUTVOLTAGE15VALUE

Page 36 of the Philips FMod-TCP BOX user manual — TYPE
Page 36 · click to enlarge
Page 36

36 / 58

TYPE

Register Address Register Name Function Read/Write Control

0x00 TYPE Product ID Read only

Register Size Register structure

4 Bytes Unsigned Int 16bits (HH-HL) TYPE Unsigned Int 16bits (LH-LL) MODEL

Description: Product identifier composed with a Type and Model number. It defines which kind of peripheral it is. Normally different modules TYPE are not software compatible.

ExampleTYPE = 0x00080000 means Type =8 (FMod-TCP BOX), Model = 0
Page 37 of the Philips FMod-TCP BOX user manual — VERSION
Page 37 · click to enlarge
Page 37

37 / 58

VERSION

Register Address Register Name Function Read/Write Control

0x01 VERSION Software ID Read only

Register Size Register structure

4 Bytes Unsigned Int 16bits (HH-HL) Version Unsigned Int 16bits (LH-LL) Revision

Description: Firmware identifier composed with a Version and Revision number. Same Version with different Revision is backward compatible.

Example: Firmware 0x0001000A = Version 1, Revision 10 is compatible with all earlier revisions of the same version (ver 1.0 to 1.9). However, it has new functionalities (which are deactivated by default) or code optimizations.

Page 38 of the Philips FMod-TCP BOX user manual — RESET CPU
Page 38 · click to enlarge
Page 38

38 / 58

RESET CPU

Function Address Function Name Function Read/Write Control

0x02 RESETCPU Restart processor Write only

0 Byte none none

Description: Reboots the device. The communication will be lost.

Page 39 of the Philips FMod-TCP BOX user manual — SAVE USER PARAMETERS
Page 39 · click to enlarge
Page 39

39 / 58

SAVE USER PARAMETERS

Function Address Function Name Function Read/Write Control

0x03 SAVEUSERPARAMETERS Saves all in EEPROM Write only

0 Byte none none

DescriptionSaves the following parameters to user EEPROM space:

ƒ 0x12 IPADDRESS ƒ 0x13 SUBNETMASK ƒ 0x14 TCPTIMEOUT ƒ 0x15 MODULENAME ƒ 0x16 RS232CONFIG

Page 40 of the Philips FMod-TCP BOX user manual — RESTORE USER PARAMETERS
Page 40 · click to enlarge
Page 40

40 / 58

RESTORE USER PARAMETERS

Function Address Function Name Function Read/Write Control

0x04 RESTOREUSERPARAMETERS Restores saved values Write only

0 Byte none none

DescriptionRestores the following parameters from user EEPROM space:

ƒ 0x12 IPADDRESS ƒ 0x13 SUBNETMASK ƒ 0x14 TCPTIMEOUT ƒ 0x15 MODULENAME ƒ 0x16 RS232CONFIG

Page 41 of the Philips FMod-TCP BOX user manual — RESTORE FACTORY PARAMETERS
Page 41 · click to enlarge
Page 41

41 / 58

RESTORE FACTORY PARAMETERS

Function Address Function Name Function Read/Write Control

0x05 RESTOREFACTORYPARAMETERS Factory default Write only

0 Byte none none

DescriptionRestores the following parameters from factory EEPROM space:

ƒ 0x12 IPADDRESS ƒ 0x13 SUBNETMASK ƒ 0x14 TCPTIMEOUT ƒ 0x15 MODULENAME ƒ 0x16 RS232CONFIG

Page 42 of the Philips FMod-TCP BOX user manual — SAVE FACTORY PARAMETERS
Page 42 · click to enlarge
Page 42

42 / 58

SAVE FACTORY PARAMETERS

Function Address Function Name Function Read/Write Control

0x06 SAVEFACTORYPARAMETERS Save factory default Write only

0 Byte none none

DescriptionSaves the following parameters to factory EEPROM space:

ƒ 0x12 IPADDRESS ƒ 0x13 SUBNETMASK ƒ 0x14 TCPTIMEOUT ƒ 0x15 MODULENAME ƒ 0x16 RS232CONFIG

Page 43 of the Philips FMod-TCP BOX user manual — VOLTAGE
Page 43 · click to enlarge
Page 43

43 / 58

VOLTAGE

Register Address Register Name Function Read/Write Control

0x07 VOLTAGE Power input voltage Read only

4 Bytes Signed (2’s cplt) Int 16 (HH-HL) +16 bits fixed point (LH-LL) Volt

DescriptionInput Voltage
LimitsMax 0x7FFFFFFxx = 32’767.996 Min 0x000000xx = 0.0 Step 0x000001xx = 0.004
ExampleWhen read 0x00234567 = 2311527 , Voltage = 35.27 (2311527/655636)

Information: Over 32 V (0x00200000) the overvoltage warning bit is set and the overvoltage protection diode should increase power current. Below 12 V (0x000C0000) the undervolatge warning bit is set. Below effective 6.5 V (0x00068000), this value has no meaning.

Active: Each time the processor is running.

Page 44 of the Philips FMod-TCP BOX user manual — WARNING
Page 44 · click to enlarge
Page 44

44 / 58

WARNING

Register Address Register Name Function Read/Write Control

0x08 WARNING Bit to bit state R/W

4 Byte Unsigned Int 32 bits , each bit independent none

Description: Each information/warning/error is contained in 2 bits: the first one (from LSB to MSB) shows the actual state, the next one shows if this state appeared previously. Only the bits that show the past states can be cleared by writing 0x00000000 to WARNING register.

Bits when set 0-1 Over-temperature occurred on outputs stage. 2-3 Over-current occurred on outputs stage. 4-5 Under-voltage of the power input. 6-7 Over-voltage of the power input. Other bits are reserved. If any warning bit is set, the LED on the SOS button will become red.

Default valuebits 31 -> 0 0x00000000

Active: Each time the processor is running.

Page 45 of the Philips FMod-TCP BOX user manual — COM OPTIONS
Page 45 · click to enlarge
Page 45

45 / 58

COM OPTIONS

Register Address Register Name Function Read/Write Control

0x10 COMOPTIONS Communication options Read/Write

4 Bytes 32 individual bits none

Description: This register is reserved for future use.

Page 46 of the Philips FMod-TCP BOX user manual — ETHERNET MAC
Page 46 · click to enlarge
Page 46

46 / 58

ETHERNET MAC

Register Address Register Name Function Read/Write Control

0x11 ETHERNETMAC Hardware network ID Read only

6 Bytes 6 x Unsigned Bytes none

Description: A standard hardware unique identifier (worldwide) for each device on an Ethernet network.

Page 47 of the Philips FMod-TCP BOX user manual — IP ADDRESS
Page 47 · click to enlarge
Page 47

47 / 58

IP ADDRESS

Register Address Register Name Function Read/Write Control

0x12 IPADDRESS IP network ID Read/Write

4 Bytes 4 x Unsigned Bytes none

Description: Network identifier used for TCP/IP and UDP/IP. The values 255 (0xFF) and 0 (0x00) are reserved for broadcast and network addresses and should not be used in this register.

Default value169.254.5.5

Example: For the IP=192.168.16.14 (0xC0, 0xA8, 0x10, 0x0E), write 0xC0A8100E to IPADDRESS.

Page 48 of the Philips FMod-TCP BOX user manual — SUBNET MASK
Page 48 · click to enlarge
Page 48

48 / 58

SUBNET MASK

Register Address Register Name Function Read/Write Control

0x13 SUBNETMASK IP subnet mask Read/Write

4 Bytes 4 x Unsigned Bytes none

Description: Network IP subnet mask used for TCP/IP and UDP/IP.

Notes: The module will change for a new subnet mask only when all of its communications ports are closed. Do not forget to use a SAVEUSERPARAMETERS command. If you do not want to use subnets, use the following subnet mask when IP address byte 0 is: >0 and 127 and 191 and

Default value255.255.0.0

Example: For the IP=10.2.6.45 and subnet mask = 255.255.0.0: IP address class = A Æ netID = 10, subNetID = 2 and hostID = 6.45

Page 49 of the Philips FMod-TCP BOX user manual — TCP TIMEOUT
Page 49 · click to enlarge
Page 49

49 / 58

TCP TIMEOUT

Register Address Register Name Function Read/Write Control

0x14 TCPTIMEOUT Timeout for TCP connection Read/Write

1 Byte Unsigned Int 8 bits sec

Description: The TCP timeout is a value (in seconds) after which the user will be disconnected if the device has not been accessed in the meantime. If the value is 0, the TCP timeout is deactivated. In this case however, if the client crashes during connection, the communication will never be closed on the module’s side! Because a maximum of 4 communications are allowed at the same time on the module, one of them will be blocked. If the client crashes four times, all of the 4 communications will be blocked and the module will have to be reset! The timeout for each TCP/IP connection is reloaded when there is traffic through the port.

Default value30
LimitationsMax value: 255
Page 50 of the Philips FMod-TCP BOX user manual — MODULE NAME
Page 50 · click to enlarge
Page 50

50 / 58

MODULE NAME

Register Address Register Name Function Read/Write Control

0x15 MODULENAME Module’s ASCII name Read/Write

16 Bytes 16 (only) x Unsigned Bytes (CHAR) none

Description: Name and/or description of the module.

Example: For the name “Hello Module”; extend to 16 byte the name: “Hello Module”+5x space=16 Byte. So write 0x48656C6C 6F204D6F 64756C65 20202020.

Page 51 of the Philips FMod-TCP BOX user manual — RS232 CONFIG
Page 51 · click to enlarge
Page 51

51 / 58

RS232 CONFIG

Register Address Register Name Function Read/Write Control

RS232 baud rate and flow control configuration

1 Byte Unsigned Int 8 bits none

Description: RS232 baud rate and flow control configuration.

Bits 0-2 Baud rate configuration : 0 : 4800 bds 1 : 9600 bps (default) 2 : 19200 bps 3 : 38400 bps 4 : 57600 bps 5 : 115200 bps 6 : 115200 bps 7 : 115200 bps Bits 3-6 Reserved Bit 7 Hardware flow control bit (0 = disabled, 1 = enabled)

Default value1 (9600 bps without flow control)

0x16 RS232CONFIG · Read/Write

Page 52 of the Philips FMod-TCP BOX user manual — I2C SPeeD
Page 52 · click to enlarge
Page 52

52 / 58

I2C SPeeD

Register Address Register Name Function Read/Write Control

0x18 I2CSPD I2C speed setting Read/Write

1 Byte Unsigned Int 8 bits none

Description: I2C speed setting between ~39kHz and 400kHz. The value of this parameter must be computed with the following formula based on the wanted speed:

1 2 10 2

wanted CSpeed I CSPD I

Default value99 (100kHz)
ExamplesMost common speeds: 100kHz : I2CSPD = 99 400kHz : I2CSPD = 24

7 − =

Page 53 of the Philips FMod-TCP BOX user manual — TCP CONNECTIONS OPENED
Page 53 · click to enlarge
Page 53

53 / 58

TCP CONNECTIONS OPENED

Register Address Register Name Function Read/Write Control

Number of TCP connections that are opened

1 Byte Unsigned Int 8 bits none

Description: Number of users connected to the device using TCP. Value can be 0 to 4.

0x1A TCPCONNECTIONSOPENED · Read only

Page 54 of the Philips FMod-TCP BOX user manual — ANALOG INPUTS THRESHOLD
Page 54 · click to enlarge
Page 54

54 / 58

ANALOG INPUTS THRESHOLD

Register Address Register Name Function Read/Write Control

AD converter threshold on inputs

4 Bytes Signed (2’s cplt) Int 16 (HH-HL) +16 bits fixed point (LH-LL) Volt

Description: Defines the threshold used by the AD converter on inputs pins to define input state as low or high (0 or 1).

Default6.0 V

Example: If your inputs use 5V TTL signals, set this value between 1 and 4 V.

0x20 ANALOGINPUTSTHRESHOLD · Read/Write

Page 55 of the Philips FMod-TCP BOX user manual — INPUTS
Page 55 · click to enlarge
Page 55

55 / 58

INPUTS

Register Address Register Name Function Read/Write Control

0x21 INPUTS 16 inputs states Read only

2 Bytes Unsigned Int 16 bits, each bit independent none

Description: Show digital state of each inputs pin. The state is defined by comparing actual input voltage with the ANALOG INPUTS THRESHOLD.

Bit 0 INPUT #1 Bit 1 INPUT #2 Bit 2 INPUT #3 Bit 3 INPUT #4 Bit 4 INPUT #5 Bit 5 INPUT #6 Bit 6 INPUT #7 Bit 7 INPUT #8 Bit 8 INPUT #9 Bit 9 INPUT #10 Bit 10 INPUT #11 Bit 11 INPUT #12 Bit 12 INPUT #13 Bit 13 INPUT #14 Bit 14 INPUT #15 Bit 15 INPUT #16

Example: b'0000 0000 0000 0111' Æ Inputs number 1, 2 and 3 are high and others are low.

Page 56 of the Philips FMod-TCP BOX user manual — OUTPUTS
Page 56 · click to enlarge
Page 56

56 / 58

OUTPUTS

Register Address Register Name Function Read/Write Control

0x23 OUTPUTS Sets outputs states Read/Write

2 Bytes Unsigned Int 16 bits, each bit independent none

Description: Controls the state of each of the output pins.

Bit 0 OUTPUT#1 (Relay A) Bit 1 OUTPUT#2 (Relay B) Bit 2 OUTPUT#3 Bit 3 OUTPUT#4 Bit 4 OUTPUT#5 Bit 5 OUTPUT#6 Bit 6 OUTPUT#7 Bit 7 OUTPUT#8 Bit 8 OUTPUT#9 Bit 9 OUTPUT#10 Bit 10 OUTPUT#11 Bit 11 OUTPUT#12 Bit 12 OUTPUT#13 Bit 13 OUTPUT#14 Bit 14 OUTPUT#15 Bit 15 OUTPUT#16

Example: b'0000 0000 0000 0111' Æ Outputs number 1, 2 and 3 are high and others are low.

Page 57 of the Philips FMod-TCP BOX user manual — INPUT VOLTAGE x VALUE
Page 57 · click to enlarge
Page 57

57 / 58

INPUT VOLTAGE x VALUE

Registers Addresses Register Name Function Read/Write Control

0x30 to 0x3F INPUTVOLTAGExVALUE Last INPUTVx A/D conversion result Read only

4 Bytes Signed (2’s cplt) Int 16 (HH-HL) +16 bits fixed point (LH-LL) Volt

Description: Voltage value of the 16 inputs pins between -12V and 12V. This value saturates at ~ -15.5V and 24V.

Page 58 of the Philips FMod-TCP BOX user manual — 58 / 58
Page 58 · click to enlarge
Page 58

58 / 58

Contact address : FiveCo - Innovative Engineering PSE-C CH-1015 Lausanne Switzerland Tel: +41 21 693 86 71 Fax: +41 21 693 86 70 www.fiveco.ch [email protected]

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Philips FMod-TCP BOX

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Philips FMod-TCP BOX

Be the first to ask — other owners or our team will answer.

Original document

Philips FMod-TCP BOX manual PDF

58 pages·1.8 MB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…