Instruction/ maintenance manual of the product CS-1754 ATEN Technology
Go to page of 68
PS/2 – USB KVM Switch CS-1754 CS-1758 User Manual www.aten.com.
CS-1754 / CS-1758 User Manual ii FCC Information This is an FCC Class A product. In a domestic environment this product may cause radio interference in which cas e the user may be required to tak e adequate measures.
CS-1754 / CS-1758 User Manual iii User Information Online Registration Be sure to register your product at our online support center: International – http :/ /supp ort.
CS-1754 / CS-1758 User Manual iv Package Content s 1 CS-1754 or CS-1758 KVM Switch 1 Firmware Upgrade Cable 1 Power Adapter 1 Rack Mount Kit 1 User Manual 1 Quick Start Guide Check to make sure that all the comp onents are present and that nothing got damaged in shipping .
CS-1754 / CS-1758 User Manual v Content s FCC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii RoHS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CS-1754 / CS-1758 User Manual vi 4. OSD Operation OSD Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 OSD Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CS-1754 / CS-1758 User Manual vii About this Manual This User Manual is provided to help you get the most from your c/c system. It covers all aspects of installation, configurati on and op erati on. An overview of the information fou nd in th e manual is provided below.
CS-1754 / CS-1758 User Manual viii Conventions This manual uses the following conven tio ns: Product Information For information abo ut all ATEN produ cts and how they can help you connect without limits, vi si t ATEN on the Web or co ntact an ATEN Authorized Reseller.
1 Chapter 1 Introduction Overview The CS-1754 and CS-175 8 USB KVM (Key b oard, Vi deo, Mouse) Swit ches are control units that allow access an d control of up to 4 (CS-1754) or 8 (CS- 1758) computers from a single USB keyb oard , USB mouse, and monitor console.
CS-1754 / CS-1758 User Manual 2 Features Dual function KVM-USB switch One console controls 4 (CS-1754) or 8 (CS-1758) com put ers Cascadable to three levels for con trol of up to 512 compu.
1. Introduction 3 Hardware Requirement s Console A VGA, SVGA, or Multisync monitor capable of the highest resolution that you will be using on any com puter in the in stallation. A USB mouse A USB keyboard Computers The following equipm ent must be installed on each computer: A VGA, SVGA or Multisync card.
CS-1754 / CS-1758 User Manual 4 CS-1754 / CS-1758 Front View 4 3 1 & 2 4 3 1 & 2.
1. Introduction 5 No. Component Description 1 Port Selection Switches Press a switch to access the computer attached to its corresponding port. Pressing buttons 1 and 2 simultaneously for 2 seconds performs a keyboard and mouse reset.
CS-1754 / CS-1758 User Manual 6 CS-1754 / CS-1758 Rear View F/W UPGRADE NORMAL RECOVER 1 3 2 4 5 F/W UPGRADE NORMAL RECOVER 1 23 4 5.
1. Introduction 7 No. Component Description 1 Firmware Upgrade Port The Firmware Upgrade Cable th at transfers the firmware upgrade data from the administrator's computer to the switch (see page 43 ), plugs into this RJ-1 1 connector .
CS-1754 / CS-1758 User Manual 8 This Page Intentionally Left Blank.
9 Chapter 2 Inst allation S t acking and Rack Mounting St acking Switches can be stacked one on top of th e other using the stacking brackets that come already attached to the unit: 1. Important safety in formation rega rding the placement of this device is provided on page 49.
CS-1754 / CS-1758 User Manual 10 Rack Mounting The CS-1754 / CS-1758 can be mount ed in a 1U sy stem rack. To rack mount the unit, do the follow ing: 1. Remove the stacking brackets by unsc rewing them from the unit , as shown in the diagram, below: 2.
2. Installation 11 Single St ag e Inst allation Refer to the installation diagrams on the follow ing pag e as you perform the following steps. The numbers in the diagrams correspond to the steps: 1. Plug your USB keyboard, USB mouse, monitor, microphone and speakers into the Console Ports located on the un it's rear pan el.
CS-1754 / CS-1758 User Manual 12 Single Stage Inst allation Di agram F/W UPGRADE NORMAL RECOVER 1 1 2 4 3.
2. Installation 13 USB Cable Connection PS/2 Cable Connection 3 3.
CS-1754 / CS-1758 User Manual 14 T wo S t ag e Inst allation To control even more comp uters, up to four / eig ht additional Master View CS- 1754/CS-1758 un its can be cascaded from the KVM ports of the First Stage unit. The cascaded Master Views that co nnect back to the First Stage unit are considered Second Stage units.
2. Installation 15 6. For each Second Stage unit, plug the power adapter cable into its Power Jack, then plug the power adapter into an AC source. 7. Plug the First Stage unit's power adap ter cable into its Power Jack, then plug the power adapter into an AC source.
CS-1754 / CS-1758 User Manual 16 Three St age Inst allation The procedures for setting up a three stage installation are essentially the same as for a two stage instal lation. With a three stag e setup, as many as 64 (CS-1754) or 512 (CS-1758) computers can be controlled in a complete installation.
2. Installation 17 Three St age Inst allation Diag ram F/W UPGRADE NORMAL RECOVER NORMAL RECOVER.
CS-1754 / CS-1758 User Manual 18 This Page Intentionally Left Blank.
19 Chapter 3 Basic Operation Hot Plugging The CS-1754 / CS-1758 support s hot plugging – components can be removed and added back into the inst allation by unplugging and replu gging their cables without having to shut the switch dow n.
CS-1754 / CS-1758 User Manual 20 Powering Off and Rest arting If it becomes necessary to Power Off one of the switches , before starting it back up you must do the following: 1.
3. Basic Operation 21 Port ID Numbering Each KVM Port on a CS-1754 / CS-17 58 installation is assigned a un ique Port ID . You can directly access any computer on any level of the installation by spec.
CS-1754 / CS-1758 User Manual 22 Port Selection The CS-1754 / CS-1758 provides three met hods to ob tain instant access to any computer in your installation: Manual, OSD (On Screen Display), and H otkey. Manual Simply press the appropriate Port S election Switch on the CS-1754 / CS-1758's front panel.
23 Chapter 4 OSD Operation OSD Overview The On Screen Display (OSD) is used to han dle all computer control and switching procedures. All procedures st art from the OSD Main Screen.
CS-1754 / CS-1758 User Manual 24 Please note the following: The diagram depicts the administrator's Main Screen. The user Main Screen does not show the F4 ADM function. OSD always starts in Li st view , with the hi ghlight bar at the same position it was in the last time it was closed.
4. OSD Operation 25 OSD Main Screen Headings OSD Functions OSD functions are used to configure and control th e OSD. For exam ple, you can: rapidly switch to any port; scan selected ports only; limit the list you wish to view; designate a port as a Quick Vi ew Port; create or edit a port name; or make OSD setting adjustments.
CS-1754 / CS-1758 User Manual 26 F1 GOTO GOTO allows you to switch directly to a port eit her by keying in the port's Name , or its Port ID . T o use the Name method, ke y in 1 ; key in the port's N ame; then press [Enter] . T o use the Port ID method, key in 2 ; key in the Port ID ; then press [Enter] .
4. OSD Operation 27 F3 SET This function allows the administrato r and each user to set up their own working environment. A separate profile for each is stored by the OSD and is activated according to the Username that was provided during Login. To change a setting: 1.
CS-1754 / CS-1758 User Manual 28 (Continued from previous page.) Setting Functio n PORT ID DISPLA Y MODE Selects how the Port ID is displayed: the Port Number alone ( PORT NUMBER ); the Port Name alone ( PORT NAME ); or the Port Number plus the Port Name ( PORT NUMBER + PORT NAME ).
4. OSD Operation 29 F4 ADM F4 is an administrator only fun ction. It allows the administrator to configure and control the overall operation of th e OSD. To change a setting doubl e click it; or use the Up and Down Arrow Keys to move the highligh t bar to it then press [Enter] .
CS-1754 / CS-1758 User Manual 30 (Continued from previous page.) (Continues on next page.) Setting Functio n EDIT PORT NAMES T o help remember which computer is attached to a particular port, every port can be given a name. This function allo ws the administrator to create, modify , or delete port names.
4. OSD Operation 31 (Continued from previous page.) Setting Function SET QUICK VIEW PORTS This function lets the administrator select which Ports to include as Quick View ports. Note: Only the Ports currently chosen for the LIST view on the main OSD screen (see F2 LIST , page 26), show up here.
CS-1754 / CS-1758 User Manual 32 F7 SCAN The SCAN function allows you to automa tical ly switch among the available computers at regular intervals so that you can monitor their activi ty without having to take the trouble of switching manu ally.
4. OSD Operation 33 F8 LOUT LOUT (Log out) logs you out of OSD cont rol of the co mputers, and blanks the Console screen. After using this function you must log in all over again to regain access to the OSD.
CS-1754 / CS-1758 User Manual 34 This Page Intentionally Left Blank.
35 Chapter 5 Hotkey Operation The CS-1754 / CS-175 8 's hotkey function m akes it convenient to control your KVM installation from the keyb oard . Note: The hotkey function must be enabled to use ho tkey op erations. See HOTKEY COMMAND MODE , page 28, for details.
CS-1754 / CS-1758 User Manual 36 Hotkey Port Access Hotkey Port Access allows you to sel ect which computer has the KVM focus. The CS-1754 / CS-1758 provides the follow ing Hotkey Port Access features.
5. Hotkey Operation 37 While you are in Auto Scan Mode, you can pause the scanning in order to keep the focus on a particular computer by pressing P , or with a Left Click of the mouse. During the time that Auto Scanning is paused, the Command Line displays: Auto Scan: Paused.
CS-1754 / CS-1758 User Manual 38 Plat form Setup The CS-1754 / CS-1758's default port sett ings are fo r a PC Compatible operating platform. You can modify the platform setting for each port by bringing the KVM focus to the port you want to change and usin g the hotkey combinations shown in the table below.
5. Hotkey Operation 39 Hotkey Summary T able Note: The brackets indicate the keys you should press. Simply press the indicated keys – do not type the brackets. [Num Lock] + [-] [Port ID] [Enter] Switches the KVM focus to the computer that corresponds to that Port ID [A] Invokes Auto Scan Mode.
CS-1754 / CS-1758 User Manual 40 This Page Intentionally Left Blank.
41 Chapter 6 Keyboard Emulation Mac Keyboard The PC compatible (101/104 key) keyboard can emu late the functions of the Mac keyboard. The emulation mappings are listed in the table below. Note: When using key combinations, press and release the first key (Ctrl), then press and release the activation key .
CS-1754 / CS-1758 User Manual 42 Sun Keyboard The PC compatible (101/104 key) keyboard can emul ate the fu ncti ons of the Sun keyboard when t he Control key [Ctrl] is used in conjunction with other keys. The corresponding function s are shown in the table below.
43 Chapter 7 The Firmware Upgrade Utility The Windows-based Firmware Upgrade Uti lit y (FWUpg rade.exe) provides a smooth, automated process for u pgrading the KVM switch's firmware. New firmware upgrad e packages are posted on our web site as new firmware revisions become available.
CS-1754 / CS-1758 User Manual 44 (Continued from previous page.) 4. Shut down all of the computers on your KVM installation. 5. From your KV M swi t ch console, bring up the OSD (see page 23) and select the F4 ADM function. 6. Scroll down to FIRMW ARE UPGRADE.
7. The Firmware Upgrade Utility 45 3. Click Next to co ntinue. The Firmware Upgrade U tility main screen appears. The devices capable of be ing upgraded are listed in the Device List panel: The Utility inspects your installation. All th e devices capable of being upgraded by the package are listed in the Device List panel.
CS-1754 / CS-1758 User Manual 46 5. After you have made your devi ce selection(s), Click Next to perform the upgrade. If you enabled Check Firmware V ersion , the Utility compar es the device's firmware level with that of the upgrad e files.
7. The Firmware Upgrade Utility 47 Upgrade Succeeded After the upgrade has completed, a screen appears to inform you that the procedure was successful: Click Finish to close the Firmwa re Upgrade Utility. Upgrade Failed If the upgrade failed to complete succe ssfully a dialog box appears asking if you want to retry.
CS-1754 / CS-1758 User Manual 48 Firmware Upgrade Recovery There are basically three conditions th at call for firmware upgrade recovery: When you invoke Firmware Upgrad e Mode (see Preparation , page 43), but decide not to pro ceed with the upgrade.
49 Appendix Safety Instructions General Read all of these instructions. Save them for future reference. Follow all warnings and instructions marked on the dev ice. Do not place the device on any unstable su rf ace (cart, stand, table, etc.
CS-1754 / CS-1758 User Manual 50 T o help protect y our system from sudden, transient increases and decreases in electrical power , use a su rge suppressor , line conditioner , or un-interruptible power supply (U PS). Position system cables and power cable s carefully; Be sure that nothing rests on any cables.
51 Rack Mounting Before working on the rack, ma ke su re that the stabilizer s are secured to the rack, extended to the floor , and that the full w eight of the rack rests on the floor . Install front and side stabilizers on a single rack or front stabilizers for joined multiple ra cks before work ing on the rack.
CS-1754 / CS-1758 User Manual 52 T echnical Support International North America When you contact u s, please have the followin g information ready beforehand: Product model number, serial number , and date of purchase. Y our computer configuration, includin g operatin g system, revision level, expansion cards, and software.
53 CS-1754 / CS-1758 Connection T ables The following tables indicate the relationshi p between the number of Master View units and the number of computers that they control: CS-1758 MVs Computers MVs.
CS-1754 / CS-1758 User Manual 54 CS-1754 OSD Factory Default Settings The factory default se ttings are as follows: MVs Computers MVs Comput ers MVs Computers MVs Compute rs 1 1 – 4 7 19 – 22 13 3.
55 Administrator Login Failure If you are unable to perform an Admini strator login (because the Username and Password information has become corrupted, or you have forgotte n it, for example), you can clear the login info rmation with the following procedure: 1.
CS-1754 / CS-1758 User Manual 56 Specifications Function CS-1754 CS-1758 Computer Connections Direct 4 8 Max 64 (via Cascade) 512 (via Cascade) Port Selection OSD; Hotkey; Pushbutt on Connectors Conso.
57 T roubleshooting Symptom Possible Cause Action Erratic Behavior Unit not re ceiving enough power Use a DC 5V power adapter if you are not already using one. If you are already using a power adapter , check that it matches the system specifications (DC 5V) and that it is plugged in and functioning properly .
CS-1754 / CS-1758 User Manual 58 Limited W arranty IN NO EVENT SHALL THE DIRECT VENDOR'S LIABILI TY EXCE ED THE PRICE PAID FOR THE PRODUCT FROM DIRE CT, INDIRECT, SPECIAL, I NCIDENTAL, OR CONSEQUENTIAL DAMAGES RESUL TING FRO M THE USE OF THE PRODUCT, DISK, OR ITS DOCUMENTATION.
59 Index A Activate Beeper, 30 ADM, 29 Administrator functions, 29 Administrator Login Failure, 55 Auto Scan Mode exit, 32 Auto Scanning, 32 Scan Durati on, 28 B Beeper Activate, 30 C Clear the Nam e .
CS-1754 / CS-1758 User Manual 60 O Online Registration, iii OSD Factory Default Settings, 54 Functions, 2 5 Hotkey, 27 Logout, 33 Main Screen Headings, 25 Overview, 23 P Password, 29 Pause, 32 Port ID.
An important point after buying a device ATEN Technology CS-1754 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought ATEN Technology CS-1754 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data ATEN Technology CS-1754 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, ATEN Technology CS-1754 you will learn all the available features of the product, as well as information on its operation. The information that you get ATEN Technology CS-1754 will certainly help you make a decision on the purchase.
If you already are a holder of ATEN Technology CS-1754, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime ATEN Technology CS-1754.
However, one of the most important roles played by the user manual is to help in solving problems with ATEN Technology CS-1754. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device ATEN Technology CS-1754 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center