Instruction/ maintenance manual of the product ACS-1714 ATEN Technology
Go to page of 24
User Manual ACS-1712 ACS-1714 2001-07-05.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Subpart J of Part 15 of the FCC Rul es. The se limits are designed to provide reasonable protection against harmful interf erence in a residential installation.
Packing List The complete Master View ACS-1712 / ACS-1714 package consists of: M One ACS-1712 or ACS-1714 KVM Switch M One Power Adapter M One User Manual Check to make sure that the unit was not damaged in shipping. If you encounter a problem, contact your dealer.
Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Hardware Requirements .
Overview The Master View ACS-1712 and ACS-1714 represent a revolutionary new direction in KVM (Keyboard, Video, Mouse) Switches. The ACS-1712 and ACS-1714 are dual function two and four Port KVM Switches combined with 2 Port USB Hubs.
Features M Dual Function KVM-USB Switch M One Console Controls 2 (ACS-1712 ) or 4 (ACS-1714 ) Computers and Two Additional USB Devices M USB Keyboard and Mouse M Independent Switching of KVM and Additional USB Ports - Cont rol one Computer while Printing From a Second Computer at the Same Time M Fully Compliant with the USB 1.
Hardware Requirements Console M A VGA, SVGA, or Mult isync monitor capable of the highest resolut ion that you will be using on any computer in the installation. M A USB style mouse M A USB style keyboard Computer The following equipment must be installed on each computer: M A VGA, SVGA or Multisync card.
Introduction Front View* 1. Port Selection Switch es M Press a switch to access the computer attached to the corresponding port. M Pressing Buttons 1 and 2 simultaneously for 2 seconds starts Auto Scan Mode . See p. 14 for details. 2. Port LEDs The Port LEDs are built into the Port Selection Swit ches.
Rear View* 1. Power Jack The power adapter cable plugs in here. 2. Console Port Section M The two type A USB connectors (upper row) are for USB peripherals (printers, scanners, etc. ), to plug int o. M The HDB-15 female connector is for your monitor to plug into.
Installation Before you Begin 1. Make sure that power to all the devices you will be connecting up have been turned off. You must unplug the power cords of any computers that have the Keyboard Power On function. Otherwise, the switch will still receive power from the computer.
Operation Hot Plugging The Master View ACS-1712 / ACS-1714 supports USB hot plugging - components can be removed and added back into the installation by unplugging their cables from the CPU ports without the need to shut the unit down.
Port Selection The Master View ACS-1712 / ACS-1714 provides three methods to obtain instant access to any computer on your installation: Manual; Hotkey ; and OSD. M Manual Simply press the appropriate Port Selection Switch on the Master View’s front panel.
Port ID Numbering CPU ID Numbering Each CPU port on a Master View installation is assigned a single digit number (1 or 2 for the ACS-1712; 1 to 4 for the ACS-1714). The Port ID of a computer is derived from the CPU Port number it is connect ed to. For example, a computer connected to CPU Port 3 has a Port ID of 3.
Hotkey Summary Table Combination Action [Ctrl] + [Ctrl] Invokes OS D (Default) [Scroll Lock] + [S croll Lock] Invokes OSD (A lternate Method) [Ctrl]+[Shi ft]+[Alt]+[1] Switches ac cess to the computer that c orresponds to Port ID number 1. [Ctrl]+[Shi ft]+[Alt]+[2] Switches ac cess to the computer that c orresponds to Port ID number 2.
OSD Operation OSD Overview On Screen Display (OSD), provides a menu driven interface to handle the computer switching procedure. Although Hotkey swit ching st ill works, using OSD is a great deal more convenient. All operations start from the OSD Main Menu.
OSD Navigation M [Esc] cancels the current selection, or dismisses the current menu and moves back to the menu one level above. If you are at the highest menu level, it deactivates OSD. M To activate a CPU port, use the F1 and F4 keys to move the CPU Port Highlight Bar through the list.
OSD Main Menu Headings Heading Explanation PN This column lists the Port ID numbers for all the CPU ports on the installation. The s implest method to acces s a particular computer is move the Highlight Bar to its corresponding port, then press [Enter].
F5-F8 PREV USB / NEXT USB M Pressing [F5] Switches access to the USB peripherals from the currently active computer to the Previous one on the installation. If you are at the first computer, you cycle back to the last one. Move the Highlight Bar to the port you want then press [Enter].
F10 SET UP Pressing [F10] brings up the OSD configuration menu. To change a setting: 1. Move the highlight bar through the list using the Up and Down Arrow keys ( ↑↓ ), then press [Enter]. 2. On the submenu that appears, move the highlight bar to the choice you want and press [Enter].
Setting Function SET PASSWORD Allows you to s et a password in order to control access to the console. S ee O SD Secur ity (p. 17) for password setting details. SET SCAN DURATION Determines how long the displ ay dwells on each port as it cycles through the selected ports i n Auto Scan Mode.
OSD Security In order to prevent unauthorized access to the computers, the OSD provides a password security feature. If a password has been set, the OSD will request that the user specify it before allowing entry. To set a password: 1. Press [F10] to bring up the SET UP configuration menu.
Appendix Troubleshooting Symptom Possible Cause Action Erratic behavior. Unit not recei ving enough power under self-powered operation. Use the Power Adapter that was supplied with the unit to provide external power. Pressing Hotkeys gets no response.
Specifications Function ACS-1712 ACS-1714 Computer Connections 2 4 CPU Port Selec t ion Front Panel Switc hes; Hotkeys; OSD USB Port Sel e ction Hotkeys; OSD LEDs On Line 2 (Orange) 4 (Orange) Selecte.
Limited Warranty IN NO EVENT SHALL THE DIRECT VENDO R’S LI ABI LITY EXCEED THE PRICE PAID FOR THE PRODUCT FRO M THE DIRECT , INDI RECT , SPECI AL, INCIDENTAL OR CONSEQUENT IAL DAMAG ES RESULTING FRO M THE USE OF THE PRODUCT, DISK OR ITS DOCUMENTAT ION.
An important point after buying a device ATEN Technology ACS-1714 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought ATEN Technology ACS-1714 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data ATEN Technology ACS-1714 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, ATEN Technology ACS-1714 you will learn all the available features of the product, as well as information on its operation. The information that you get ATEN Technology ACS-1714 will certainly help you make a decision on the purchase.
If you already are a holder of ATEN Technology ACS-1714, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime ATEN Technology ACS-1714.
However, one of the most important roles played by the user manual is to help in solving problems with ATEN Technology ACS-1714. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device ATEN Technology ACS-1714 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center