Instruction/ maintenance manual of the product CS-128A ATEN
Go to page of 30
8 Port K VM Switc h User Manual CS-128A.
.
Packing List The compl ete Maste r View Pro package co nsists of: w One CS-128A KVM Switch w One Power Adapter w One User Ma nual Check to m ake sure that the u nit was not damaged in shipping.
Contents O v e r v i e w... ............ ......... ......... ............ ......... ........ 1 F e a t u r e s ....... ......... ......... ............ ......... ......... ........ 2 H a r d w a r eR e q i r e m e n t s ....... ......... ............ .
Overview The Master Vie w CS-128A KVM Switch is a control unit that allows access to multiple computers from a single console (keyboard, monitor, and mouse). Before the develop ment of the Master View, the only way to control multiple compute r configurations from a single co nsole was through a complex and costly network system.
Features w Cascadabl e To Thre e Levels - Control Up to 512 co mputers F rom a Singl e Console w No Software Required - Computer Selec tion via Front Panel Switches, Hot Keys, or OSD (On Sc reen Displ.
Hardware Reqireme nts Console w A VGA, SVGA, or Multisync monitor capable of the highes t resolution that you will be using on any computer in the installation . w A PS/2 st yle mouse w A PS/2 style keyboard PC w The following equ ipment must be installed on ea ch computer: w A VGA, SVGA or Multis ync card.
Introductio n Front View 1. Port LE Ds On Line: Lights ORANGE to indicate that the computer attached to the corresponding port is up and running. If the LED is flashing, it indicates that th e Port is being used for Casc ading to a nother Master Vi ew switch .
Rear View: 1. Power Jac k The unit is desig ned to be n on-powered (no e xternal powe r required). It gets its power from the computers it con nects to. Generally spe aking, the only time that external power is require d is when you daisy chain it, or if opera- tion become s erratic because the unit isn’t obtaining enough power from the computer.
Install ation Before you Begin 1. Make su re that power to all the devices you will b e connecting up have b een turned off. You must unplug the powe r cords of any compute rs that have the Keyboard Pow er On function. Otherwise, the switc h will receive power from the com puter.
4. Turn on the power to the compute rs. Note: If you choose t o use externa l power, the CS-128A must be plu gged in and receiv ing power before turning on the power to the c omputers. Two Stage Ins tallation To control eve n more computers, up to eight ad ditional CS-128A units ca n be cascaded from the CP U port s of t he Firs t Stag e unit.
Three Stage Ins tallat ion The procedure s for setting up a three stage inst allation are e ssentially the same as fo r a two stag e instal lation. With a three sta ge setup, as ma ny as 512 computers can be controlled in a comple te installation.
4. Repe at steps 1 - 3 for any other Third Stage units you wish to connec t. 5. For each T hird Sta ge unit , plug th e power adapt er cable in to the Maste r View’s Power J ack; plug t he power adapt er into an AC sou rce. 6. Pl ug in the pow er adapte rs for all the Sec ond Stage M aster Vie w units.
Operation Hot Plugging The Master Vie w CS-128A supports ho t plugging - components can be removed an d added back into the insta llation by unplugging their cables from the CPU ports without the need to shut the unit down.
Powering Of f and Restar ting If it becomes nec essary to Power Off one of th e Master View units, before starting it back up you must do the following: 1.
Port Selection The Master Vie w CS-128A provides thre e methods to obtain insta nt access to any computer in your installation : Manual; Hotkey ; and OSD (On Screen Display). w Manual Simply press the appropriate Port Selec tion Switch on the Master View’s front panel.
Port ID Numbering ID Numbering Overview Each CPU Port o n a Master View insta llation is assigned a unique Port ID. You can direc tly acces s any comput er on any leve l of the inst allati on by spe cifying the Port ID of the C PU Port that the computer is conne cted to - either with the Hotkey port selection method, or from the OSD.
Port Key In Examp les 1. To ac cess a computer attached to Port 3 of a Single Stage installation, key in 3 for the Port ID, as follows: [Ctrl]+[Alt]+[Shift] 3 [Enter] 2.
OSD Operation OSD Overview OSD (On Screen Display), provide s a menu driven in terface to handle the compute r switching procedure . Although Hotkey switching still works, using OSD is a grea t deal m.
OSD Men u Navigation w [Esc] can cels the current selec tion, or dismisses the c urrent menu and moves back to the menu one leve l above. If you are at the highest menu level, it dea ctivat es OSD. w Use the Up a nd Down Arrow Keys or clic k on the Up and Down Triangle symbols ( st ) to m ove up or down through the list one line at a time.
OSD Main M enu Headin gs Heading E xplanat ion PN This col umn lists t he Port ID number s (Station Numbe r - Port Number) for all the CPU P orts on the instal lation. The s implest method to ac cess a particul ar compu ter is move the Highl ight Bar to it, then pr ess [Ente r].
w F2 Scan: Pressing [F2] i nitiate s Quick View Scanning , in whi ch the OSD cycl es through all the ports th at are currently selecte d in the List view (see F3 , below), and displa ys each one for the a mount of time specified with the Se t Scan Duration setting unde r the F6 SET function (see p.
Move the Highlight Ba r to the choice you wa nt, then press [Enter]. An icon appears before the choice to indica te that it is the currently selected one. Note: 1. Yo u can ac cess any port on a ny list by usin g the Navig ation Keys then pressing [Enter].
w F6 Set: Pressing [F6] brings up th e OSD configuration m enu. To chang e a setting : 1. Move the highlight bar to the choice you want, then press [Enter]. 2. On the submenu that appears next, move the highlight bar to the choice you want a nd press [Enter].
Settin g Functio n SET PASSWORD Allows you to set a password in order to control access to: Clearin g the Name Li st; Restori ng Default V alues ; and Locking /Unlocking t he Console . See the OSD Security Features s ection, bel ow, for passwo rd setting detai ls.
Factory D efault Sett ings The factory default settings are a s follows: Setting Def ault Displa y Duration Alway s On Displa y Mode The Port Numb er plus the Port Name Scan Dur ation 3 Secon ds OSD Sec urit y In order to preve nt unauthorized a ccess to the computers, the OSD provides a password se curity feat ure.
Appendix Master View - Com puter Connect ion Table The foll owing t able indi cates t he relatio nship b etween th e number of Mas ter View Units and the numbe r of computers that they control: MVs Co.
Troubles hooting Sympto m Possibl e Cause Act ion Erratic behavio r. Unit not r eceiving enough power und er self- powered operati on. Use the Power Ada pter that was supplie d with the unit to pr ovide exter nal power. Pressing Hot Keys get s no respons e.
Specifications Funct ion Spe cifi catio n Computer Connecti ons Direct 8 Max 512 (via Daisy Chain ) Port Sele ction Front Pa nel Switc hes Hot Keys On Screen Display LEDs On Lin e Port 8 (Orang e) Sele cted Port 8 (Green) Console Connector s Keyboa rd 1 x 6 pin mini-DIN fem ale Mouse 1 x 6 pin mini-DIN fem ale Vide o 1 x HDB-15 female (s td.
Federal Com municatio ns Commission Stat ement This dev ice comp lies with Pa rt 15 of the FC C Rule s. Operati on is subject to the following two conditions: (1) this device may not cause harmful interferenc e, and (2) this device must accept any interfe rence received, including interference t hat may ca use undesire d operation.
An important point after buying a device ATEN CS-128A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought ATEN CS-128A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data ATEN CS-128A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, ATEN CS-128A you will learn all the available features of the product, as well as information on its operation. The information that you get ATEN CS-128A will certainly help you make a decision on the purchase.
If you already are a holder of ATEN CS-128A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime ATEN CS-128A.
However, one of the most important roles played by the user manual is to help in solving problems with ATEN CS-128A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device ATEN CS-128A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center