Manual
0150-0241 Phillips ProBridge


© 2004 GE Security
All Rights Reserved.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Any GE Security software supplied with GE Security products is proprietary and furnished under license and can be used or copied only in accordance with the terms of such license.
This document contains proprietary information that is protected by copyright. No part of this document may be reproduced or transmitted in any form or by any means without the prior written permission of GE Security.
The information contained in this document is subject to change without notice. GE Security in keeping pace with technological advances, is a company of product innovation. Therefore, it is difficult to ensure that all information provided is entirely accurate and up-to-date. GE Security accepts no responsibility for inaccuracies or omissions and specifically disclaims any liabilities, losses, or risks, personal or otherwise, incurred as a consequence, directly or indirectly, of the use or application of any of the contents of this document.
You are cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
For the latest product specifications, visit GE Security online at www. GE-Security.com or contact your sales representative.
For technical support before and after installation, call 800-469-1676.
Technical support is available 24 hours a day, 7 days a week.
Tech Support 541-740-3589 (all other times)
Main 800-343-3358 or 541-754-9133
0150-0241B / May 2004
Main 541-754-7162



The Kalatel CBR-PB2-PHILIPS is a specific ProBridge unit for interfacing the DVMRe family of digital video multiplex/recorders and providing local keyboard control via a CBR-KB3 or KTD-405 keypad to a Philips AutoDome.
(1) CBR-PB2-PHILIPS ProBridge. This product includes:
The CBR-PB2-PHILIPS is compatible with all Kalatel DVMRe digital video multiplex/recorders equipped with RS-485 network capabilities except installations with a CBR-KB1 Keypad.
Compatible units include the Kalatel DVMRe digital video units and various Kalatel Multiplexer models (Simplex, Triplex, Matrix). Please check the specifications of the particular Kalatel product for RS-485 network support.
Power: Ensure that the installation site’s AC power is stable and within the rated voltage of the external power supply. If the site’s AC power is likely to have spikes or dips, use power line conditioning or an Uninterruptible Power Supply.

Temperature: Observe the unit’s ambient temperature specifications when choosing a location for the unit. Extremes of heat or cold beyond the specified operating temperature limits may cause the unit to fail. Do not install this unit on top of other hot equipment.
Moisture: Do not expose the unit to rain or moisture. Moisture can damage internal components. Do not install this unit near sources of water.
RS485 Limitations: Total length of the RS-485 network is limited to 3000’.
The ProBridge is furnished with a power supply (110 or 240 VAC). Do not use any other power supply with this product. The manufacturer accepts no responsibility for damage caused by the use of any other power supply.
Make sure installation is complete and all connections are made before applying power to the unit.
4310-0007 120VAC Power Supply
4310-0008 220VAC Power Supply

Carefully and completely read the manuals for each piece of equipment before attempting to install and connect this equipment.
Before you start connecting other optional accessory equipment to your system, make sure that all, power, video, VCR, and monitor connections are completed, and everything is working correctly.
Wire the telemetry equipment according to that unit’s installation instruction. Use the internal diagnostic testing capabilities of the telemetry receiver to verify that the power and connections to the lens and motors are correct, and function properly.
Using the Diagram on the following page, connect the equipment in the following order:
Please note, that whenever the ProBridge is used with a KTD-405 the KB3 PTZ Protocol option in the KTD-405 menu must be set to YES. See Supervisor Programming in the KTD-405 manual.

This drawing depicts one Philips AutoDome connected via an RS485/422 network to a Kalatel DVMReTriplex unit, that provides remote PTZ control over Ethernet via WaveReader software, and a CBR-KB3 or KTD-405 keypad.

AUX 2 A U X 1 A U X 3 AUX 4

Part Number : 4310-0034B Communication Type: RS-485 Connector Type: RJ45 ,RJ45 Cable Required: 5 Foot RJ45 to RJ45 Triplex RS485 Cable (Supplied). Connects ProBridge to Triplex and CBR-KB3 or KTD-405 keypad.

RJ45 RJ45 Connector Connector


Connector Type: RJ-45 ,DB9F Cable Required: 6 Foot RJ-45 to DB9F RS232 Cable (Supplied). Connects ProBridge to Philips Data Converter Unit.

RJ-45 Connector · DB-9F Connector

If you are unable to verify control of the PTZ camera, please do the following:

The unit ships from the factory with the correct settings for most applications and should not require the installer to open the unit and change the jumper settings. However, for trouble shooting purposes we have included the default jumper settings.
Place the ProBridge unit face down. Using a small Phillips screwdriver, carefully remove the screws located near each corner of the unit. Once the screws have been removed, lift the cover to detach.

With the cover removed, orient the unit as shown here. There are two sets of configurable jumpers. One set, located on the left side of the board, controls how the unit communicates (JP2, JP3, JP4 and JP5). The other set, located at the bottom of the board (P6, twelve pin header) determines specific configuration elements for equipment interfacing.

ProBridge Circuit Board

The default jumper settings are listed below:



All specifications are subject to change without notice. Kalatel believes that all specifications are correct, however no liability is assumed for omissions or errors.


The Philips ProBridge (CBR-PB2-PHILIPS) is not an addressable device and requires no user settings. The device simply acts as an interpreter, translating the remote telemetry commands into a format useable by the P/T/Z controller.
Each camera input, whether a fixed camera or a Pan/Tilt/Zoom (P/T/Z) unit, is connected to a Kalatel unit input. The Kalatel unit has an RS-485 network address, and so does the P/T/Z camera receiver. This address determines when the telemetry receiver responds to commands sent over the RS-485 data line. Consult the PTZ installation manual for specific instructions on setting these addresses.

The CBR-PB2-PHILIPS can be used in conjunction with multiple Kalatel units, and/or keypads controlling the domes and the Kalatel units. Since the ProBridge unit is a terminated device, care should be used when using this unit in a mixed application.
The RS-485 network is a multi-drop wiring configuration of maximum length 3,000 feet (1000 meters). RJ45 cable and RJ45 connectors are used for most hookups (see the installation/connection diagram). Some equipment manufactured by Kalatel may use flying leads, terminal blocks, or other types of connections.
Most units have looping RS-485 network connectors. Either socket can be used. Do not use third-party RS-485 equipment without first consulting Kalatel Technical Support for information on compatibility with other Kalatel equipment.


The Philips AutoDome can be addressed from 1 to 9998. The CBR-PB2- PHILIPS ProBridge can control camera addresses from 1 to 9998, however the CBR-KB3 keyboard can control cameras from 1 to 1024. WaveReader software can only control cameras from 1 to 8160.



Philips AutoDome Addresses are calculated as follows:
Philips AutoDome Address = Camera Address + 32 X (Network Address – 1)
Set the switches on the LTC8780 as follows:
S101: Switches 1, 3, and 4 set to OFF. Switch 2 set to ON.
S102: Switches 1 –3 set on ON, switch 4 set to OFF.
See Philips LTC8780 manual for details.
Keyboards (CBR-KB3/J and KTD-405) are typically used to provide initial configuration of the Philips AutoDome for setting addresses and presets.

In some specific cases keyboards may be used in conjunction with the CBR-PB2-PHILIPS units where multiple Kalatel units are being controlled via one or more local Keyboard. Available keyboards are only involved when an RS-485 is configured with CBR-KB2/J, CBR-KB3/J and KTD-405 Keyboards. Please contact Technical Support for additional instructions concerning these special installations.

ALT Key Shift Key Aux Keys

The remote keyboard has 8 AUX function keys that can be assigned to do some Philips AutoDome features as follows:
Aux2 On/Off Auto Pan
Aux3 On/Off Continuous Playback A Start/Stop
Aux4 On/Off Continuous Playback B Start/Stop
Aux5 On/Off Record Sequence A
Aux6 On/Off Record Sequence B
Aux7 Momentary Preset Tour Start. Move Joystick to stop.
Aux8 Momentary Start Advanced Menu Mode.
The Philips AutoDome can store up to 99 preset operations (1-99). With the remote keyboard, the number of presets that can be set up is 32 (1-32). With WaveReader, the number of presets that can be set up is 16 (1-16).

To set a new Preset position:
To clear an existing Preset position:
To set a new Preset position:

If the unit requires factory service, contact the dealer who supplied the unit to you for the correct procedures on returning the unit to the factory or the nearest factory service center. If the dealer is not available, contact the manufacturer of the unit as detailed below and request a Return Material Authorization number (RMA). The unit’s serial number must be provided before an RMA number can be issued. Units returned to the factory for service must have freight and insurance prepaid, and must show the RMA number clearly on all shipping documents. The failure symptoms must be clearly described by the operator and enclosed with the unit together with a copy of the original supplier’s invoice. Failure to comply with these instructions will delay service of the unit, and may result in the unit not being accepted by the Repair Center.
3050 Red Hill Ave.
Costa Mesa, CA 92626
United States of America
For warranty information, see the following page.
GE Security warrants all of its equipment for three years from the date of purchase. This warranty covers any defects in materials and workmanship. Equipment failures that are due to improper installation, modification, abuse, or acts of nature will not be covered by this warranty. The repair department will evaluate all equipment returned for repair to determine warranty coverage. The Tech Support Manager will resolve any questions that may arise during evaluation to make a final determination.
The warranty specifically covers any defects in material and workmanship and does not cover equipment that has been abused, damaged, or modified.
For all warranty repairs, GE Security will cover all costs, including parts, labor, and shipping. Repaired equipment will be returned via the same method of shipment in which it was received. If a customer requests a faster return shipment, the difference will be charged.
For all non-warranty repairs, the customer will be billed for parts, labor, and shipping. Labor will be billed in half-hour increments.
GE Security

Note: Customers requesting an estimate prior to repair will be notified by phone. If they cannot be reached, they will be notified by fax. If we are unable to reach the contact person for repair authorization after one phone attempt and two fax attempts, the equipment will be returned without being repaired. We will hold equipment no longer than two weeks.
When an advance replacement is required, we will send the customer replacement equipment from our stock and receive the returned product in exchange. The received equipment will be evaluated and the repair department will determine whether it is a warranty replacement. If it is non-warranty, see our repair policy above for details. The following guidelines will be used for all advance replacements:
If you have questions about this policy, please contact GE Security’s RMA Department at 800-469-1676.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.