4 KEG COOLER 10 KEG COOLER
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
4”

Tools Required
The Cam Lock Fastening Method
This utility cooler utilizes the cam-lock fastening method. (See illustration on below.)
Insert the cam lock wrench into the lock before the panels are pushed together. Turn the handle Cam Hole counterclockwise as far as it will go to fully cock the cam. Note: The cam must be fully cocked to assure proper locking. The panels should then be pushed together tightly and locked by turning the wrench clockwise.
Some panels have been protected with a strip- pable film to prevent surface damage. Remove this film before assembly. It is very difficult to remove it from the panel edges after panels have been joined together. Note: Do not store panels with protective film in sunlight or high temperature areas for an extended period of time.
Plugs are provided to insert in cam-lock holes after final assembly.
Placing the Utility Cooler
This utility cooler should not be installed tight against any building or adjacent cooler wall. A minimum of two inches must be provided for air circulation. Shims for leveling the floor must also be incorporated into overall height and clearance requirements.
Remote Units: A minimum four inch clearance is required between the top of the utility cooler and the ceiling of the building in which it is being installed.
Self-contained Units: Sufficient clearance above the cooler must be allowed for ceiling panel and condensing unit installation. For ventilation requirements, see page 7.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Preparing the Floor
Assembly
Snap a chalk line on the building floor to establish cooler location. Place floor panel(s) on the floor and check for level. A level floor is essential to ensure that vertical panels will be plumb. If shimming is required to level the sections, the shims must extend under the entire section, not just the edges. Shims should be used at each end, at all wall seams, and at each floor seam. They should not be spaced further than 24 inches apart.

SEAL COOLER TO FLOOR AFTER UNIT IS LEVEL AND
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.





Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.





Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Electrical Requirements
There should be nothing on or around the machin- ery compartment area which will restrict the flow of room temperature air to the condenser or over the compressor.
The package unit must be installed so that the wir- ing conforms to, and is in accordance with National and Local Electrical Codes. (See Condensing Unit Data Plate for Electrical Specifications.
Starting The Cooler
Inspect the machinery compartment every 60 days. A heavy accumulation of dirt and/or grease on the front of the condensing unit (radiator) must be cleaned off with a stiff brush or vacuum cleaner. Be careful not to bend the aluminum fins on the con- densing unit.
Allow the empty utility cooler to operate 24 hours for a settling-out period before use.
The temperature control is located on the evapo- rator housing. It is factory adjusted to maintain a temperature of approximately 34° F. cut out and 40° F. cut in. Cut out temperatures lower than 34°F. are not advisable as excessive frost may accumu- late on the evaporator.
This Utility Cooler is fully warranted against defects in both material and workmanship for a period of one (1) year from date of sale. Defective parts must be returned to Perlick freight prepaid. All parts found to be defective upon inspection will be replaced on a no-charge basis, F.O.B. our factory. Perlick is not responsible for parts damaged by alteration, unauthorized service, accident or abuse. All costs incident to replacement, including labor, refrigerant, and/or loss of sales are incidental to this warranty and must be borne by the user.
If excessive frost does accumulate, the unit is operating at too cold a temperature. To defrost the evaporator, turn off the electrical power to the con- densing unit or turn the control to a warmer posi- tion to allow the fan motor to defrost it. The control should then be reset to a temperature that will not ice up the evaporator. A plastic drain hose should be attached to the drain pan of the evaporator and routed through the wall panel. A receptacle should be provided for accumulated condensing water or connect to a building drain facility.
Air-cooled units must be furnished with sufficent ventilation to maintain their efficiency. The table at right indicates the minimum room size/cubic footage, only the space above the condensing unit can be used. When the room size is below minimum, some type of forced ventilation must be provided.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.


How to Order Replacement Parts Contact your local Perlick dealer to order replacement parts.
Be prepared to provide the model and serial num- ber of the cooler. The serial number is printed on a label which is attached to the inside wall, adjacent to the evaporator housing.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

COMPRESSOR
TERMINALS
GREEN
BROWN
R S
WHITE
RELAY
OVERLOAD
FAN
GREEN
BLACK
WHITE
SWITCH
LIGHT
GREEN
WHITE
BLACK
WHITE
BLACK
(ELECTRONIC) THERMOSTAT (4 MIN. “ON” DELAY)
BROWN
WHITE
EVAPORATOR FAN MOTORS
(ALTERNATE) THERMOSTAT
BLACK
(STANDARD)
BROWN
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

M
FAN CONDENSER
RELAY
GREEN
BROWN
WHITE
YELLOW
OVERLOAD
BLUE
RED
S
R
COMPRESSOR
TERMINALS
GREEN
BLACK
WHITE
SWITCH
LIGHT
GREEN
WHITE
BLACK
WHITE
BROWN
(ELECTRONIC) THERMOSTAT (4 MIN. “ON” DELAY)
BLACK
WHITE
EVAPORATOR FAN MOTORS
(ALTERNATE) THERMOSTAT
BLACK BROWN
(STANDARD)
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.