TOP VIEW
19 7/8” [505] OPENING
27 1/2” [699] OPENING
2 1/16” [52] CORD EXIT
FRONT VIEW END VIEW BACK VIEW
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Installing Casters (Portable Models Only)
I Casters* .
Attach four casters to the cabinet bottom; rigid casters at the rear and swivel casters on the front. Use the supplied 1/4”- 20 x 3/4” hex head self- tapping machine screws. Placing the Cabinet
I Faucet Standard.
I Faucet Head Assembly.
I Spanner Wrench for Faucet.
I Black Connector Hose 3⁄16” x 3’.
I 5⁄16” Air Hose.
Push the cabinet into place using rollers when necessary. Important: Proper air flow around the condensing unit is necessary for efficient operation. Never obstruct the air flow in and out of the condensing unit. Leveling the Cabinet
I Bag of Miscellaneous Parts.
I #2 Phillips Screwdriver.
I Spanner Wrench (included).
I 10” Crescent Wrench.
When the cabinet is in place, check installation with carpenter’s level. When perfectly level, accumulated water will drain out. A slight pitch to the drain side will not harm the cabinet. Water may accumulate if cabinet is pitched to the opposite side. Installing the Faucet and Dispensing Head
I 9/16” Allen Wrench.
I 5/16” and 3/8” Hex Socket.
Portable Model No plumbing connections are required. Condensate from the cooling coil is automatically evaporated. Drain pan waste is accumulated in the plastic bottle installed inside the cabinet. Underbar Model Features a floor drain with a 3⁄4” female pipe thread connection for disposal of both condensate and drip pan waste. Remove bottom 1” NPS or side 3⁄4” drain plug attach male pipe to create external drain.
Before you begin: Wash dispensing head and faucet. Flush beer, dispensing head and faucet lines with fresh water.
I Apply RTV around the base of the dispensing
head to seal it to the top. Align the dispensing head over the five holes on the cabinet top and use the five stainless steel #10-32 x 13⁄4” Phillips pan head stainless steel machine screws to secure standard to cabinet top. Wipe off excess RTV to complete the seal. I Attach faucet to standard using spanner
The cabinet must be connected to a separately fused power source (see electrical specification plate) and grounded in accordance with National and Local Electrical Codes. Caution: Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate. Uncrating and Inspection
wrench to tighten coupling. Attach faucet handle to faucet. I Insert flexible plastic air hose six to seven
inches into bottom of faucet standard. Secure hose with tie wrap (supplied).
Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transportation company. Perlick is not responsible for damage in transit.
To avoid compressor damage, after returning cabinet to an upright position, let unit stand for 24 hours before plugging it in and running the unit.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Connecting the Regulator to the CO 2 Cylinder
I Place one brown leather washer into black beer
I Remove blue plug from regulator fitting.
line connector hose on hex nut side. Screw connector to stainless steel beverage line on faucet standard. Tighten with a wrench, but do not over tighten. I Make sure lever handle on the keg coupler is in
with wrench until vertically straight. Be sure that shut-off valve (black lever) on regulator is in the OFF (horizontal) position. I Place a screw clamp over end of red air line
the UP (untapped) position. Place one brown leather washer into wing nut end of black beer line connector hose and thread onto top of keg coupler. Hand tighten. I Place clamp on one end of red air line. Push
and push onto regulator tailpiece. Tighten clamp with a screwdriver.
end over air valve located inside cabinet. Tighten clamp with screwdriver. Turn shut-off valve to OFF (horizontal) position. I Place clamp on the other end of red air line and
HAND VALVE
CO2 PRESSURE GAUGE
PSI 10 50
PERLICK
push over tailpiece on coupler. Tighten clamp with screwdriver. CAUTION: Do not use keg coupler as a handle to lift keg.
Tapping a Single Valve Keg (Sankey) :

REGULATOR ADJUSTING SCREW
SHUT-OFF VALVE (BLACK LEVER IN CLOSED POSITION)
Single Valve Keg Coupler
Adjusting the CO 2 Gas Flow
DOWN
I Turn regulator adjusting screw counterclockwise
until it turns freely. I Turn hand valve counterclockwise on CO2
cylinder to the fully open position. I Turn regulator adjusting screw clockwise until
I Be sure beer faucet is in closed position.
desired pressure is reached (approximately 12-15 lbs.). Tighten stop nut on adjusting screw. I Open shut-off valve on bottom of regulator.
I Align keg lugs with lug openings on bottom
of coupler. I Turn clockwise 1⁄4 turn. Pull handle out and
down. Keg is now tapped. I Open shut-off valve on air distributor located
when untapping keg.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

or dirt before attaching regulator. I Store CO2 cylinder and regulator assembly
Dilute a small amount of liquid dishwashing soap and rub the soapy mixture around each connection. If bubbles appear, tighten connection.
upright. I Allow only properly trained and experienced
personnel to handle high pressure gas. NEVER...
I Connect cylinder directly to a keg without a
I Turn CO2 hand valve clockwise until seated and
regulator (reducing valve). I Drop or throw regulator or CO2 cylinder.
close shut-off valve on regulator. I Unscrew regulator from cylinder fitting.
I Transport CO2 cylinder in a closed vehicle.
I Apply oil to a regulator.
I Replace carbonic washer (Part No. 157F2P),
if needed and reattach regulator to filled cylinder. I Turn CO2 hand valve counterclockwise until
I Shut off CO2 cylinder when not in use. You will
not save gas by doing so! I Allow untrained, inexperienced personnel to
fully open. Turn regulator shut-off valve to open position. I Adjust CO2 gas flow as required, turning
handle high pressure gas.
Failure to heed this warning could result in personal injury or death.
clockwise for higher pressure.
ALWAYS...
I Connect a regulator (reducing valve) to
CO2 cylinder. I Secure cylinder in upright position whether in
storage or in use. I Keep cylinder away from heat. Rupture disc
vents at 122° F. maximum. I Ventilate room after high pressure gas leakage.
I Check the last DOT test date on cylinder neck
before filling. If more than five years old, the cylinder must be retested to DOT specifications. I Be sure CO2 cylinder outlet fitting is free of dust
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

At temperatures lower than 30° F., beer will freeze. When beer freezes, the alcohol in the beer may separate and cause the beer to be cloudy with an “off” taste.
One of the most common causes of dispensing problems is improper temperature. Draft beer should be stored at a temperature between 32° and 38°. At warmer temperatures, beer will foam.
Draft beer is not pasteurized and must be kept cool at all times.
Adjusting the temperature
The Partymaster Dispenser is equipped with a heavy-duty refrigeration system designed to automatically maintain a storage temperature of 36-41 degrees F. The control is factory set at 38 degrees F.
The temperature control is inside the cabinet on the right-hand side of the evaporator fan panel assembly. You will need a screwdriver to turn the adjusting screw. Make small adjustments until the desired temperature is achieved.
I Colder Temperatures:
Turn the adjusting screw clockwise (to the right). I Warmer Temperatures:
Turn the adjusting screw counterclockwise (to the left). In normal operation the condensing unit will turn on and off, depending on the cooling load required. The condenser fan motor turns off and on with the condensing unit. The evaporator fan motor runs continuously. The fan motors are lifetime lubricated and will require no oiling. NOTE: Cabinet Temperatures lower than 34° will not allow for proper defrosting of the evaporator coil. If defrosting is necessary, turn the control knob to the OFF position until coil is defrosted.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

The entire beer system, to include the faucet, flexible beer line and tapping devices must be cleaned at regular intervals. We recommend flushing the entire system with fresh water immediately after a keg has been emptied. Once each month the system should be cleaned chemically. It is recommended that you purchase Perlick’s Pump Type Sterilizer, as shown below. It is equipped with an adapter that attaches directly to the faucet shank in lieu of the faucet. It is also available with a slip coupling for those who choose to clean their faucets in place.
I Beer Stone:
All beer contains calcium which is present from the grains used in the brewing process. it is an important natural material in draft systems in that as it oxidizes it coats the internal parts of the beer lines and equipment. This thin coat of beer stone helps prevent the beer from picking up strong metallic or plastic flavors as it flows through the system. The beer stone will continue to build if the system is not cleaned properly or regularly and can cause drawing problems if it begins to flake off. Beer stone is present if one can see a brownish color on the faucet or inner wall of the beer line, or tobacco- like flakes in the beer.

Cleaning the draft beer system will help to eliminate the build-up of the following materials:
Use a mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Never use a scouring pad or abrasive cleanser. NOTE: An industrial strength, commercial cleaner can be used to clean the outside of painted cabinets.
I Bacteria:
Beer is an excellent food for bacteria (none of which is harmful). Proper conditions may begin the growth of bacteria in draft beer and on the beer faucet. By regular cleaning, we prevent this bacterial buildup and maintain the quality of the draft beer. Greenish or yel- lowish colored material on the faucet may indicate bacterial growth.
Use a long handled, stiff brush to clean the dirt from the front surface of the condenser. Keeping the condenser free from dust and dirt will ensure effi- cient operation. CAUTION: Do not bend the fins while brushing the front of the condenser.
No. 887P
I Yeast:
All domestic draft beers contain a small amount of yeast which remains in the beer from the fermentation process. When the temperature of draft beer exceeds 50° a process of secondary fermentation may take place. The beer faucet may exhibit a white colored substance (yeast build up) if not cleaned on a regular basis.
The condenser (located behind the back cover) should be inspected every 30 days and cleaned, if necessary. Failure to keep the condenser clean will cause a loss in condensing unit efficiency.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.


Start with a clean glass. Place the glass at a 45° angle, one inch below faucet. Do not let the glass touch the faucet. Open the faucet all the way.
reached half full, gradually bring the glass to the upright
Let the remaining beer run straight down the middle of the glass. This ensures proper release of CO2 by producing a 3⁄4” to 1” foam head.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

I Cloudy Beer:
I Wild Beer :
Dispensed beer has either too much foam or is all foam. CAUSES:
I Dirty glass.
I Dirty faucet or beer line.
I Frozen or nearly frozen beer.
I Beer has been dispensed improperly.
I Old beer.
Solution: See pouring instructions on page 8. I Regulator pressure is set too high.
I Beer that has not been refrigerated for a
long period of time.
I Warm keg temperature.
Solution: Keg must be colder than 40°. Target temperature is between 36° and 38° F. I Cabinet door is opened and closed
frequently and temperature is warmer than 38° F. Solution: Adjust temperature to between 36° and 38° F. I Kinks, dents or obstructions in the line.
I Beer foam is 25% liquid beer and 75% CO2
gas. Don’t waste it! I Most people prefer beer stored at 38° F.
I Using oddly shaped glasses. Frosted,
I Beer lines and faucets require regular cleaning
waxed or styrofoam containers may cause foaming. I Dispenser has been turned off for a
(see cleaning instructions on page 7). I A fully-charged 4.2 lb. CO2 cylinder will
dispense approximately 51⁄2 to 61⁄2 half barrels. I CO2 gas gives beer its sparkling effervescence.
long period of time. I Faucet is bad, dirty or in a worn condition.
It also gives beer its creamy head of foam.
I Regulator malfunction.
Foamy head disappears quickly; beer lacks brewery fresh flavor. CAUSES:
I Dirty glassware.
I CO2 pressure is too low, due to leak or
pressure setting. I CO2 is turned off at night.
I Cooler is too cold.
I CO2 leak or defective (sticking)
check valve. I Sluggish CO2 regulator.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

9 12 8 10
16 16A
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Item Part No. No. Description 1 32499 Probe assembly 2 F40184 Probe body 3 31080-2P Ball 4 43641-1 Ball retainer 5 31087-2P Probe washer 6 31089 “O” Ring - 3-per assembly 7 43061 Body 8 23682-2P Check valve 9 157R2P Washer 10 206B-1 Tailpiece 11 2026 Coupling nut 12 31088-2P Bottom seal washer 13 31084-1 Retaining screw 14 43002A Yoke assembly w/lock 15 43001A Yoke assembly standard 16 32474-1 Wrench
8 9 10 11
Part No. Description 157L2P Beer line connector gasket 57F2P CO2 tank washer 1392R Red air hose 529 Beer hose 2928D Twin gauge CO2 regulator
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
16 5 12


Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.