EN
Perlick logo
Official user manual

Perlick DP32

12 pages·517 KB·Beverage Dispenser·PDF·ENDEFRITNLJA
Perlick DP32
Table of Contents 76 sections INSTALLATION AND OPERATION INSTRUCTIONS DIRECT DRAW DISPENSER - SELF-CONTAINED MODELS · DS Series · IMPORTANT INFORMATION · Table of Contents · … ShowHide
INSTALLATION AND OPERATION INSTRUCTIONS DIRECT DRAW DISPENSER - SELF-CONTAINED MODELSp.1DS Seriesp.1IMPORTANT INFORMATIONp.1Table of Contentsp.1SPECIFICATIONSp.2NOTE “B”p.2KEGp.218 3/4” [476] BACK LINER TO INSIDE OFp.231 1/4” [794] DOOR HEIGHT 27 7/16”p.2KEG KEGp.2DOOR SILLp.2[697] DOOR OPENINGp.219 7/8” [505] DOOR OPENINGp.2NOTE “A”p.2R23 1/2”p.2Preparing the Cabinet for Use – Direct Draw Dispensers Self-Containedp.3Parts Listp.3Suggested Tools Requiredp.3Plumbingp.3Uncrating and Inspectionp.3Placing the Cabinetp.3Electricalp.3Leveling the Cabinetp.3Installing Casters or Legs (Optional)p.3WARNING!p.3Installing the Faucet and Dispensing Headp.3Installation and Tapping – Direct Draw Dispensers Self-Containedp.4Connecting the Keg Coupler (when Supplied by Perlick)p.4Tapping a Single Valve Keg (Sankey) :p.4of the cabinet. Important: Be sure to close this valvep.4Connecting the Regulator to the CO 2 Cylinderp.5Replacing CO 2 Gas Cylinderp.5REGULATOR FITTINGp.5HAND VALVEp.5CO2 PRESSURE GAUGEp.5Proper CO 2 Handlingp.5PSI 10 50p.5PERLICKp.5CO2 GAS DRUMp.5FITTING FOR RED AIR HOSEp.5REGULATOR ADJUSTING SCREWp.5SHUT-OFF VALVE (BLACK LEVER IN CLOSED POSITION)p.5Adjusting the CO 2 Gas Flowp.5CO 2 Leak Testp.5Draft Beer Information – Direct Draw Dispensers Self-Containedp.6Temperaturep.6Refrigeration and Temperature Controlp.6Adjusting the temperaturep.6COLDERp.6COLDp.6OFFp.6Cleaning the Beer System – Direct Draw Dispensers Self-Containedp.7Cleaning the Cabinetp.7Cleaning the Condenserp.7Pouring a Perfect Glass of Beer – Direct Draw Dispensersp.8Trouble Shooting – Direct Draw Dispensers Self-Containedp.9I Cloudy Beer:p.9Beer Service Problemsp.9Beer in glass appears hazy, not clear. C AUSES :p.9I Wild Beer:p.9Beer and CO 2 Factsp.9I Flat Beer:p.9Replacement Parts – Direct Draw Dispensers Self-Containedp.10For Single Valve Keg Coupler (Series D)p.11Miscellaneousp.11Wiring Diagram – Direct Draw Dispensers Self-Containedp.12CAPPED NOT USEDp.12EVAPORATOR FAN EVAPORATOR FANp.12BLACKp.12WHITEp.12THERMOSTATp.12REDp.12GREENp.12POWER CONNECTIONp.12CONDENSING UNITp.12JUNCTION BOXp.12
Page 1 of the Perlick DP32 user manual — Table of Contents
Page 1 · Contents
Contents

Contents

INSTALLATION AND OPERATION INSTRUCTIONS DIRECT DRAW DISPENSER - SELF-CONTAINED MODELSp.1DS Seriesp.1IMPORTANT INFORMATIONp.1Table of Contentsp.1SPECIFICATIONSp.2NOTE “B”p.2KEGp.218 3/4” [476] BACK LINER TO INSIDE OFp.231 1/4” [794] DOOR HEIGHT 27 7/16”p.2KEG KEGp.2DOOR SILLp.2[697] DOOR OPENINGp.219 7/8” [505] DOOR OPENINGp.2NOTE “A”p.2R23 1/2”p.2Preparing the Cabinet for Use – Direct Draw Dispensers Self-Containedp.3Parts Listp.3Suggested Tools Requiredp.3Plumbingp.3Uncrating and Inspectionp.3Placing the Cabinetp.3Electricalp.3Leveling the Cabinetp.3Installing Casters or Legs (Optional)p.3WARNING!p.3Installing the Faucet and Dispensing Headp.3Installation and Tapping – Direct Draw Dispensers Self-Containedp.4Connecting the Keg Coupler (when Supplied by Perlick)p.4Tapping a Single Valve Keg (Sankey) :p.4of the cabinet. Important: Be sure to close this valvep.4Connecting the Regulator to the CO 2 Cylinderp.5Replacing CO 2 Gas Cylinderp.5REGULATOR FITTINGp.5HAND VALVEp.5CO2 PRESSURE GAUGEp.5Proper CO 2 Handlingp.5PSI 10 50p.5PERLICKp.5CO2 GAS DRUMp.5FITTING FOR RED AIR HOSEp.5REGULATOR ADJUSTING SCREWp.5SHUT-OFF VALVE (BLACK LEVER IN CLOSED POSITION)p.5Adjusting the CO 2 Gas Flowp.5CO 2 Leak Testp.5Draft Beer Information – Direct Draw Dispensers Self-Containedp.6Temperaturep.6Refrigeration and Temperature Controlp.6Adjusting the temperaturep.6COLDERp.6COLDp.6OFFp.6Cleaning the Beer System – Direct Draw Dispensers Self-Containedp.7Cleaning the Cabinetp.7Cleaning the Condenserp.7Pouring a Perfect Glass of Beer – Direct Draw Dispensersp.8Trouble Shooting – Direct Draw Dispensers Self-Containedp.9I Cloudy Beer:p.9Beer Service Problemsp.9Beer in glass appears hazy, not clear. C AUSES :p.9I Wild Beer:p.9Beer and CO 2 Factsp.9I Flat Beer:p.9Replacement Parts – Direct Draw Dispensers Self-Containedp.10For Single Valve Keg Coupler (Series D)p.11Miscellaneousp.11Wiring Diagram – Direct Draw Dispensers Self-Containedp.12CAPPED NOT USEDp.12EVAPORATOR FAN EVAPORATOR FANp.12BLACKp.12WHITEp.12THERMOSTATp.12REDp.12GREENp.12POWER CONNECTIONp.12CONDENSING UNITp.12JUNCTION BOXp.12
Page 2 of the Perlick DP32 user manual — NOTE “B”
Page 2 · click to enlarge
Page 2

Installation and Operating Instructions Sizes and Specifications, Direct Draw Dispensers - Self-Contained

DOOR FINISH MODEL NUMBERS BLACKDS60BDS72BDS84B STAINLESS STEELDS60SDS72SDS84S

SPECIFICATIONS

KEG CAPACITY2 Keg3 Keg4 Keg NUMBER OF DOORS223 CABINET DIMENSIONSLength Ins. (mm) 60” (1524)72” (1829)84” (2134) Depth Ins. (mm) 243/4” (629)243/4” (629)243/4” (629) Height Ins. (mm) 341/2” (876)341/2” (876)341/2” (876) NO. OF DISPENSING HEADS 112 NO. FAUCETS222 CONDENSER UNIT H.P.1/41/31/3 RUNNING LOAD - AMPS5.97.57.5 SHIP WT lbs. (kg)385 [175]425 [193]500 [227] INTERIORDoor sill: High strength polyethylene. Door pan and ceiling: High strength polystyrene. Floor pan: Satinless steel. Walls: Galvanized steel. EXTERIORAll Models: The top is 20 gauge stainless steel. The back, front and sides are stainless steel. Bottom is 18 gauge galvanized steel. Black Models: Doors and grilles are black vinyl coated steel. Stainless Models: Doors and grilles are stainless steel. REFRIGERATIONR-134a capillary tube-type. Aluminum fin and copper tube evaporator, epoxy coated coil. Forced air into dispensing head. Adjustable temperature control. Self-defrosting. Pull-out condensing unit for service and cleaning. VENTILATIONFront ventilated. ELECTRICAL115 Volt, 60 Hz., 1 Phase AC. Furnished with three prong, six foot NEMA5-15P cord. Contact Perlick for other voltage/frequency requirements. PLUMBING3/4” NPT drain exits out right end or 1” NPS out bottom. Evaporator condensate has been plumbed to a condensate pan located in the compressor housing. INSULATIONFoamed-in-place polyurethane; 2” walls, 11/2” top and floor. OPTIONAL ACCESSORIES• Optional Dispensing Heads • Leg Set • Keg Couplers • Caster Sets • Shelf Kit • Faucet Locks

84” [2134] 4 KEG 72” [1829] 3 KEG 60” [1219] 2 KEG

68” [1726] 4 KEG 56” [1492] 3 KEG 44” [1118] 2 KEG

NOTE “B”

KEG

18 3/4” [476] BACK LINER TO INSIDE OF

31 1/4” [794] DOOR HEIGHT 27 7/16”

KEG KEG

DOOR SILL

[697] DOOR OPENING

19 7/8” [505] DOOR OPENING

NOTE “A”

R23 1/2”

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Show 10 more labels / short text on this page
10 9/16” [268] · 4 1/4” [107] · 12 11/16” [322] · 3 1/8” [79] · 6 5/16” [161] · 24 3/4” [629] · 34 1/2” [876] · 1 1/8” [29] · 23 1/2” [597] · 3 11/16” [94]
Page 3 of the Perlick DP32 user manual — Installing the Faucet and Dispensing Head
Page 3 · click to enlarge
Page 3

Preparing the Cabinet for Use – Direct Draw Dispensers Self-Contained

Parts List

I Apply RTV around the base of the dispensing

I Faucet Standard.

head to seal it to the top. Align the dispensing head over the holes on the cabinet top and use screws provided to secure standard to cabinet top. Wipe off excess RTV to complete the seal. I Attach faucet to standard using spanner

I Faucet Head Assembly.

I Black Connector Hose 3⁄16” x 3’.

I 5⁄16” Air Hose.

I Spanner Wrench.

wrench to tighten coupling. Attach faucet handle to faucet. I Insert flexible plastic air hose six to seven

I Bag of Miscellaneous Parts.

Suggested Tools Required

I #2 Phillips Screwdriver.

inches into bottom of faucet standard. Secure hose with tie wrap (supplied).

I Spanner Wrench (included).

I #10 Crescent Wrench.

Plumbing

I 9/16” Allen Wrench.

The floor drain in the right rear corner is equipped with a 3/4” female pipe thread connection with side or bottom access for beer drainer waste.

I 5/16” & 3/8” Nut driver.

I Power driver.

I Remove either side or bottom drain plug with an

Uncrating and Inspection

allen wrench and attach a 3/4” male pipe (provided by plumber) to an external drain connection. Evaporator condensate has been plumbed to a condensate pan located in the compressor housing. CAUTION: Do not overtighten drain fitting as it may damage the threads.

Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transportation company. Perlick is not responsible for damage in transit.

Placing the Cabinet

Push the cabinet into place using rollers when necessary. Important: Proper air flow around the condensing unit is necessary for efficient operation. Never obstruct the air flow in and out of the condensing unit.

sleeve on the side of the cabinet in the machinery compartment. Connect this line to the pressure supply with a hose and fitting.

Electrical

Leveling the Cabinet

The cabinet must be connected to a separately fused power source (see electrical specification plate) and grounded in accordance with National and Local Electrical Codes. Caution: Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate.

When the cabinet is in place, check installation with a carpenter’s level. A slight pitch to the drain side is desired. Water may accumulate if the cabinet is pitched to the opposite side.

Installing Casters or Legs (Optional)

Attach casters to the cabinet bottom in the holes provided. Use supplied 1/4”- 20 x 3/4” hex head self-tapping machine screws. Use power driver if available.

WARNING!

To avoid compressor damage,after returning cabinet to an upright position, let unit stand for 24 hours before plugging it in and running the unit.

Installing the Faucet and Dispensing Head

Before you begin: Wash tapping devices and faucet. Flush beer, tapping device and faucet lines with fresh water.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 4 of the Perlick DP32 user manual — of the cabinet. Important: Be sure to close this valve
Page 4 · click to enlarge
Page 4

Installation and Tapping – Direct Draw Dispensers Self-Contained

Connecting the Keg Coupler (when Supplied by Perlick)

Tapping a Single Valve Keg (Sankey) :

Perlick DP32 — Connecting the Keg Coupler (when Supplied by Perlick) diagram (page 4)
Fig. 1 · Connecting the Keg Coupler (when Supplied by Perlick…

I Place one brown leather washer into black beer

line connector hose on hex nut side. Screw connector to stainless steel beverage line on faucet standard. Tighten with a wrench, but do not over tighten. I Make sure lever handle on the keg coupler is in

Single Valve Keg Coupler

the UP (untapped) position. Place one brown leather washer into wing nut end of black beer line connector hose and thread onto top of keg coupler. Hand tighten. I Place clamp on one end of red air line. Push

end over air valve located inside cabinet. Tighten clamp with screwdriver. Turn shut-off valve to OFF (horizontal) position. I Place clamp on the other end of red air line and

I Be sure beer faucet is in closed position.

I Align keg lugs with lug openings on bottom

push over tailpiece on coupler. Tighten clamp with screwdriver. CAUTION: Do not use keg coupler as a handle to lift keg.

of coupler. I Turn clockwise 1⁄4 turn. Pull handle out and

down. Keg is now tapped. I Open shut-off valve on air divider located inside

of the cabinet. Important: Be sure to close this valve

when untapping keg.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Step 1 · Step 3 · Step 2

Page 5 of the Perlick DP32 user manual — CO 2 Leak Test
Page 5 · click to enlarge
Page 5

Installation and Tapping – Direct Draw Dispensers Self-Contained

Connecting the Regulator to the CO 2 Cylinder

Replacing CO 2 Gas Cylinder

I Turn CO2 hand valve clockwise until seated and

I Remove blue plug from regulator fitting.

close shut-off valve on regulator. I Unscrew regulator from cylinder fitting.

(NoteDo not remove the carbonic washer). I Screw regulator onto gas cylinder valve. Tighten

I Replace carbonic washer (Part No. 157F2P),

with wrench until vertically straight. Be sure that shut-off valve (black lever) on regulator is in the OFF (horizontal) position. I Place a screw clamp over end of red air line

if needed and reattach regulator to filled cylinder. I Turn CO2 hand valve counterclockwise until

fully open. Turn regulator shut-off valve to open position. I Adjust CO2 gas flow as required, turning

and push onto regulator tailpiece. Tighten clamp with a screwdriver.

clockwise for higher pressure.

REGULATOR FITTING

HAND VALVE

CO2 PRESSURE GAUGE

Proper CO 2 Handling

ALWAYS...

PSI 10 50

PERLICK

I Connect a regulator (reducing valve) to

CO2 cylinder. I Secure cylinder in upright position whether in

storage or in use. I Keep cylinder away from heat. Rupture disc

CO2 GAS DRUM

vents at 122° F. maximum. I Ventilate room after high pressure gas leakage.

I Check the last DOT test date on cylinder neck

FITTING FOR RED AIR HOSE

before filling. If more than five years old, the cylinder must be retested to DOT specifications. I Be sure CO2 cylinder outlet fitting is free of dust

REGULATOR ADJUSTING SCREW

SHUT-OFF VALVE (BLACK LEVER IN CLOSED POSITION)

or dirt before attaching regulator. I Store CO2 cylinder and regulator assembly

Adjusting the CO 2 Gas Flow

upright. I Allow only properly trained and experienced

I Turn regulator adjusting screw counterclockwise

personnel to handle high pressure gas. NEVER...

until it turns freely. I Turn hand valve counterclockwise on CO2

I Connect cylinder directly to a keg without a

cylinder to the fully open position. I Turn regulator adjusting screw clockwise until

regulator (reducing valve). I Drop or throw regulator or CO2 cylinder.

desired pressure is reached (approximately 12-15 lbs.). Tighten stop nut on adjusting screw. I Open shut-off valve on bottom of regulator.

I Transport CO2 cylinder in a closed vehicle.

I Apply oil to a regulator.

I Shut off CO2 cylinder when not in use. You will

not save gas by doing so! I Allow untrained, inexperienced personnel to

CO 2 Leak Test

handle high pressure gas. Failure to heed this warning could result in personal injury or death.

Dilute a small amount of liquid dishwashing soap and rub the soapy mixture around each connection. If bubbles appear, tighten connection.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

20 40 30

Page 6 of the Perlick DP32 user manual — COLD
Page 6 · click to enlarge
Page 6

Draft Beer Information – Direct Draw Dispensers Self-Contained

Temperature

At temperatures lower than 30° F., beer will freeze. When beer freezes, the alcohol in the beer may separate and cause the beer to be cloudy with an “off” taste.

One of the most common causes of dispensing problems is improper temperature. Draft beer should be stored at a temperature between 32° and 38°. At warmer temperatures, beer will foam.

Refrigeration and Temperature Control

Adjusting the temperature

The Direct Draw Dispenser is equipped with a heavy-duty refrigeration system designed to automatically maintain a storage temperature of 36-41 degrees F. The control is factory set at 38 degrees F.

The temperature control is inside the cabinet on the right-hand side of the evaporator fan panel assembly. You will need a screwdriver to turn the adjusting screw. Make small adjustments until the desired temperature is achieved.

I Colder Temperatures:

Turn the adjusting screw clockwise (to the right). I Warmer Temperatures:

COLDER

Turn the adjusting screw counterclockwise (to the left). The condenser fan motor turns off and on with the condensing unit. The evaporator fan motor runs continuously. The fan motors are lifetime lubricated and will require no oiling. NOTE: Cabinet Temperatures lower than 34° will not allow for proper defrosting of the evaporator coil. If defrosting is necessary, turn the control knob to the OFF position until coil is defrosted.

COLD

OFF

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 7 of the Perlick DP32 user manual — Cleaning the Condenser
Page 7 · click to enlarge
Page 7

Cleaning the Beer System – Direct Draw Dispensers Self-Contained

The entire beer system, to include the faucet, flexible beer line and tapping devices must be cleaned at regular intervals. We recommend flushing the entire system with fresh water immediately after a keg has been emptied. Once each month the system should be cleaned chemically. It is recommended that you purchase Perlick’s Pump Type Cleaning Kit. It is equipped with an adapter that attaches directly to the faucet shank, jar with pump, cleaning solution, faucet brush and spanner wrench.

I Beer Stone:

All beer contains calcium which is present from the grains used in the brewing process. it is an important natural material in draft systems in that as it oxidizes it coats the internal parts of the beer lines and equipment. This thin coat of beer stone helps prevent the beer from picking up strong metallic or plastic flavors as it flows through the system. The beer stone will continue to build if the system is not cleaned properly or regularly and can cause drawing problems if it begins to flake off. Beer stone is present if one can see a brownish color on the faucet or inner wall of the beer line, or tobacco- like flakes in the beer.

Cleaning the draft beer system will help to eliminate the buildup of the following materials:

I Bacteria:

Beer is an excellent food for bacteria (none of which is harmful). Proper conditions may begin the growth of bacteria in draft beer and on the beer faucet. By regular cleaning, we prevent this bacterial buildup and maintain the quality of the draft beer. Greenish or yellowish colored material on the faucet may indicate bacterial growth.

Cleaning the Cabinet

Use a mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Never use a scouring pad or abrasive cleanser. NOTE: An industrial strength, commercial cleaner can be used to clean the outside of painted cabinets.

I Yeast:

All domestic draft beers contain a small amount of yeast which remains in the beer from the fermentation process. When the temperature of draft beer exceeds 50° a process of secondary fermentation may take place. The beer faucet may exhibit a white colored substance (yeast build up) if not cleaned on a regular basis.

Cleaning the Condenser

Use a long handled, stiff brush to clean the dirt from the front surface of the condenser. Keeping the condenser free from dust and dirt will ensure effi- cient operation. CAUTION: Do not bend the fins while brushing the front of the condenser.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 8 of the Perlick DP32 user manual — Pouring a Perfect Glass of Beer – Direct Draw Dispensers
Page 8 · click to enlarge
Page 8
Perlick DP32 — Pouring a Perfect Glass of Beer – Direct Draw Dispensers diagram (page 8)
Fig. 2 · Pouring a Perfect Glass of Beer – Direct Draw Dispen…

Pouring a Perfect Glass of Beer – Direct Draw Dispensers

Start with a clean glass. Place the glass at a 45° angle, one inch below faucet. Do not let the glass touch the faucet. Open the faucet all the way.

reached half full, gradually bring the glass to the upright

Let the remaining beer run straight down the middle of the glass. This ensures proper release of CO2 by producing a 3⁄4” to 1” foam head.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 9 of the Perlick DP32 user manual — I Flat Beer:
Page 9 · click to enlarge
Page 9

Trouble Shooting – Direct Draw Dispensers Self-Contained

I Cloudy Beer:

Beer Service Problems

Beer in glass appears hazy, not clear. C AUSES :

I Wild Beer:

Dispensed beer has either too much foam or is all foam. CAUSES:

I Dirty glass.

I Dirty faucet or beer line.

I Frozen or nearly frozen beer.

I Beer has been dispensed improperly.

I Old beer.

Solution: See pouring instructions on page 8. I Regulator pressure is set too high.

I Beer that has not been refrigerated for a

long period of time.

I Warm keg temperature.

Beer and CO 2 Facts

Solution: Keg must be colder than 40°. Target temperature is between 36° and 38° F. I Cabinet door is opened and closed

Keg SizeNo. of GallonsNo. of Oz.No. of CasesNo. of 12Oz. ServingsFull Keg Weight Quarter73⁄49923.44510587 lbs. Half151⁄21,9846.889210161 lbs.

frequently and temperature is warmer than 38° F. Solution: Adjust temperature to between 36° and 38° F. I Kinks, dents or obstructions in the line.

I Beer foam is 25% liquid beer and 75% CO2

gas. Don’t waste it! I Most people prefer beer stored at 38° F.

I Using oddly shaped glasses. Frosted,

I Beer lines and faucets require regular cleaning

waxed or styrofoam containers may cause foaming. I Dispenser has been turned off for a

(see cleaning instructions on page 7). I A fully-charged 4.2 lb. CO2 cylinder will

dispense approximately 51⁄2 to 61⁄2 half barrels. I CO2 gas gives beer its sparkling effervescence.

long period of time. I Faucet is bad, dirty or in a worn condition.

It also gives beer its creamy head of foam.

I Regulator malfunction.

I Flat Beer:

Foamy head disappears quickly; beer lacks brewery fresh flavor. CAUSES:

I Dirty glassware.

I CO2 pressure is too low, due to leak or

pressure setting. I CO2 is turned off at night.

I Cooler is too cold.

I CO2 leak or defective (sticking)

check valve. I Sluggish CO2 regulator.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 10 of the Perlick DP32 user manual — Replacement Parts – Direct Draw Dispensers Self-Contained
Page 10 · click to enlarge
Page 10

Replacement Parts – Direct Draw Dispensers Self-Contained

MODEL NOS.DS60BDS72BDS84B DS60SDS72SDS84S Condensing Units Condensing unit 115 volt, 60 hz.C22647C22646 C22646 Condensing unit515301063515301062515301062 Compressor513200314513200003513200003 Fan motor assembly215315009215315009215315009 Condenser coil153520191535201915352019 Terminal board219101538219101538219101538 Overload protectorMRT20AGK5590MRT22AGK5590MRT22AGK5590 Relay213516192135161921351619 Capacitor135565291355653213556532 Evaproator Assembly Self Contained complete65555-165555-265555-2 Evaporator coilC17511-1EPC17511-2EPC17511-2EP Liquid & Suction line650846508565085 Fan blade576995769957699 Fan motorC15239AC15239AC15239A Evaporator fan guard655576555765557 Temperature control612836128361283 Bulb clampC6634C6634C6634 Wire harness, compressor bottom655606556065560 Wire harness, evaporator655616556165561 Lock637626376236762 Space, lock63761-163761-163761-1 Lock rail65432-24SS65432-24SS65432-24SS Grille rail65432-12SS65432-12SS65432-12SS Condenser pan65565-165565-165565-1 Condenser end panel66215-1SS66215-1SS66215-1SS Grille, black66210-1266210-1266210-12 Grille, SS66210-12SS66210-12SS66210-12SS Condenser housing back65435-12SS65435-12SS65435-12SS Evaporator, liquid & suction line cover65576-1L65576-4L65576-2L Evaporator pan65526-165526-265526-2 Door sill65500-165500-165500-1 Door handle bracket65189-165189-165189-1 Door handleC31409-1C31409-1C31409-1 Door gasket66237-466237-466237-4 Cabinet hinge65436-LBRT65436-LBRT65436-LBRT Cabinet hinge65436-LBRB65436-LBRB65436-LBRB Hinge pin63679-163679-163679-1 Hinge assembly, cabinet left side65505L65505L65505L Hinge assembly, cabinet right side65505R65505R65505R *Replacement doorRD-NL2RD-NL2RD-NL2

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 11 of the Perlick DP32 user manual — Miscellaneous
Page 11 · click to enlarge
Page 11

Replacement Parts – Direct Draw Dispensers Self-Contained

For Single Valve Keg Coupler (Series D)

Item Part No. No. Description 1 32499 Probe assembly 2 F40184 Probe body 3 31080-2P Ball 4 43641-1 Ball retainer 5 31087-2P Probe washer 6 31089 “O” Ring - 3-per assembly 7 43061 Body 8 23682-2P Check valve 9 157R2P Washer 10 206B-1 Tailpiece 11 2026 Coupling nut 12 31088-2P Bottom seal washer 13 31084-1 Retaining screw 14 43002A Yoke assembly w/lock 15 43001A Yoke assembly standard 16 32474-1 Wrench

8 9 10 11

Miscellaneous

Part No. Description 157L2P Beer line connector gasket 57F2P CO2 tank washer 1392R Red air hose 529 Beer hose 2928D Twin gauge CO2 regulator

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

16 5 12

Page 12 of the Perlick DP32 user manual — CAPPED NOT USED
Page 12 · click to enlarge
Page 12

Wiring Diagram – Direct Draw Dispensers Self-Contained

DS Series 2, 3 and 4 Keg Coolers

CAPPED NOT USED

EVAPORATOR FAN EVAPORATOR FAN

BLACK

WHITE

THERMOSTAT

BLACK

BLACK

WHITE

RED

GREEN

POWER CONNECTION

CONDENSING UNIT

BLACK

WHITE

GREEN

JUNCTION BOX

  • 8300 West Good Hope Road
  • Milwaukee, WI 53223
  • Phone 414-353-7060
  • Fax 414-353-7069 Toll Free 800-558-5592
  • E-Mail: Perlick@<a href="http://Perlick.com" rel="nofollow noopener" target="_blank">Perlick.com</a>
  • <a href="http://www.Perlick.com" rel="nofollow noopener" target="_blank">www.Perlick.com</a>

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Perlick DP32

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Perlick DP32

Be the first to ask — other owners or our team will answer.

Original document

Perlick DP32 manual PDF

12 pages·517 KB·Beverage Dispenser·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…