Page 2 of the Perlick DC90ACLT user manual — *
Page 2 · click to enlarge
Page 2

Installation and Operating Instructions Specifications, ArctiCold Draft Dispenser

*

Model Nos.DC90ACLT keg capacity2 Keg CABINET Dimensions Including BumpersLength Inches. (mm)923/4” (2311) Depth Inches. (mm)261/2” (673) Height Inches. (mm)5513/16” (1354) condensing unit H.P.1/3 HP Ship wt lbs. (kg)805 (366) InteriorDoor sill: High strength polyethylene. Door pan and ceiling: High impact polystyrene. Walls and Floor pan: Stainless steel. exteriorStainless steel top and doors. Choice of stainless steel or galvanized back and sides. Bottom galvanized. RefrigerationR-134a expansion valve system. Epoxy coated aluminum fin and copper tube evaporator, coil. Digital temperature control. Self-defrosting. glycol mixture1/3 propylene glycol to 2/3 distilled water. VentilationAll sides of unit must be unobstructed to ensure adequate ventilation. PlumbingEvaporator condensate and beer waste is pre-plumbed to a waste tank located in the CO2 compartment. electricalUnit is furnished with 3-prong (NEMA) 5-15 plug, 9 foot long power cord that requires a dedicated 15 amp circuit of 115 volt, 60Hz, 1 phase AC electricity. Disconnect power cord before servicing. InsulationFoamed-in-place environmentally friendly polyurethane; 2” walls, 11/2” top and floor. OPTIONS & ACCESSORIESOptions: • Two single faucet dispensing heads or one dual faucet head. Accessories: • Keg couplers • Regulators • Faucet locks

* This product is intended for the storage of non-potentially hazardous canned and bottled products only.

Perlick DC90ACLT — * diagram (page 2)
Fig. 1

18 3/4” [476] BACK OF LINER TO INSIDE OF DOOR PAN

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 3 of the Perlick DC90ACLT user manual — Electrical
Page 3 · click to enlarge
Page 3

Preparing the Cabinet for Use – ArctiCold Draft Dispenser

Uncrating and Inspection

CABINET

Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately. Perlick is not responsible for damage in transit.

HOLE DRAIN TUBE

ACCESS

FROM DRAINER

DUMP TANK CO 2 CYLINDER ACCESS DOOR

Ensure that the unit is on a level surface and that the brakes on the casters are engaged. It is impor- tant that the unit is unobstructed on all sides to provide adequate ventilation for the refrigeration decks. Blocking the ventilation louvers may damage the compressor and void the warranty. Remove the bottom front grille to access the machine compartment. Connect the power cord to a separate dedicated circuit as described in the electrical section of this manual. Turn on the rocker switch labeled “circulating pump” and check for glycol leaks. Next, turn on the rocker switch labeled “condensing unit”. The flash chill heat exchangers and evaporator coil circuit will pull down to operating temperature in less than 1 hour in most conditions.

CHAIN FOR

SECURING CO 2 CYLINDER

REMOVABLE

DUMP TANK CO2 TANK (Must Be Secured

Electrical

The power cord is a 15 amp cord that requires 115 VAC, 60Hz, and 1 phase electricity. Refer to the wiring diagram included in this manual for a detailed schematic. WARNING: Always disconnect power cord before servicing.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

When Moving · Cabinet)

Page 4 of the Perlick DC90ACLT user manual — Tapping a Single Valve Keg (Sankey)
Page 4 · click to enlarge
Page 4

Installation and Tapping ArctiCold Draft Dispenser

Tapping a Single Valve Keg (Sankey)

  • Be sure beer faucet is in closed position.
  • Align keg lugs with lug openings on bottom of coupler.
  • T urn clockwise 1 ⁄ 4 turn. Pull handle out and down. Keg is now tapped.
  • Open shut-off valve on CO 2 distributor located inside of the cabinet.
Perlick DC90ACLT — Tapping a Single Valve Keg (Sankey) diagram (page 4)
Fig. 2 · Tapping a Single Valve Keg (Sankey)
Perlick DC90ACLT — Tapping a Single Valve Keg (Sankey) diagram (page 4)
Fig. 3 · Tapping a Single Valve Keg (Sankey)
Perlick DC90ACLT — Tapping a Single Valve Keg (Sankey) diagram (page 4)
Fig. 4 · Tapping a Single Valve Keg (Sankey)
  • Plug in top refrigeration deck, (15-amp plug), and allow condensing unit to cycle at least once, (circulation pump will run continuously), before tapping the keg.
  • Couple beer keg to system. Beer temperature in keg should not exceed 42°F.
  • Apply 14-17 PSIG carbon dioxide gas .
  • Open faucet and pour for approximately 15 seconds.
  • Close faucet and wait for at least 15 minutes to allow beer system to “pack”.
  • You are now ready to tap beer.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 5 of the Perlick DC90ACLT user manual — CO 2 Leak Test
Page 5 · click to enlarge
Page 5

Installation and Tapping ArctiCold Draft Dispenser

Connecting the Regulator to the CO 2 Cylinder

Replacing CO 2 Gas Cylinder

  • Turn CO 2 hand valve clockwise until seated and close shut-off valve on regulator.
  • Unscrew regulator from cylinder fitting.
  • Replace carbonic washer (Part No. 157F2P), if needed and reattach regulator to filled cylinder.
  • Turn CO 2 hand valve counterclockwise until fully open. Turn regulator shut-off valve to open position.
  • Adjust CO 2 gas flow as required, turning clock wise for higher pressure.
  • Remove blue plug from regulator fitting. (Note: Do not remove the carbonic washer).
  • Screw regulator onto gas cylinder valve. Tighten with wrench until vertically straight. Be sure that shut-off valve ( black lever ) on regulator is in the OFF ( horizontal ) position.
  • Place a screw clamp over end of red air line and push onto regulator tailpiece. Tighten clamp with a screwdriver.

CO2 PRESSURE GAUGE

Perlick DC90ACLT — CO2 PRESSURE GAUGE diagram (page 5)
Fig. 5

Proper CO 2 Handling

  • always ...
  • Connect a regulator (reducing valve) to CO 2 cylinder.
  • Secure cylinder in upright position whether in storage or in use.
  • Keep cylinder away from heat. Rupture disc vents at 122° F. maximum.
  • Ventilate room after high pressure gas leakage.
  • Check the last DOT test date on cylinder neck before filling. If more than five years old, the cylinder must be retested to DOT specifications.
  • Be sure CO 2 cylinder outlet fitting is free of dust or dirt before attaching regulator.
  • Store CO 2 cylinder and regulator assembly upright.
  • Allow only properly trained and experienced personnel to handle high pressure gas.

CO2 GAS DRUM

SHUT-OFF VALVE (BLACK LEVER IN CLOSED POSITION)

Adjusting the CO 2 Gas Flow

  • Turn regulator adjusting screw counterclockwise until it turns freely.
  • Turn hand valve counterclockwise on CO 2 cylinder to the fully open position.
  • Turn regulator adjusting screw clockwise until desired pressure is reached (approximately 12-15 lbs.). The desired pressure may vary based on location/elevation. Tighten stop nut on adjusting screw.
  • Open shut-off valve on bottom of regulator.
  • never ...
  • Connect cylinder directly to a keg without a regulator (reducing valve).
  • Drop or throw regulator or CO 2 cylinder.
  • Transport CO 2 cylinder in a closed vehicle.
  • Apply oil to a regulator.
  • Shut off CO 2 cylinder when not in use. You will not save gas by doing so!
  • Allow untrained, inexperienced personnel to handle high pressure gas. Failure to heed this warning could result in personal injury or death.

CO 2 Leak Test

Dilute a small amount of liquid dish washing soap and rub the soapy mixture around each connec- tion. If bubbles appear, tighten connection.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 6 of the Perlick DC90ACLT user manual — Cleaning the Cabinet
Page 6 · click to enlarge
Page 6

Cleaning the Beer System ArctiCold Draft Dispenser

The entire beer system, to include the faucet, flexible beer line and tapping devices must be cleaned at regular intervals. We recommend flushing the entire system with fresh water immediately after a keg has been emptied. Every two weeks or before each use the system should be cleaned chemically.

fermentation process. When the temperature of draft beer exceeds 50° a process of secondary fermentation may take place. The beer faucet may exhibit a white colored substance (yeast build up) if not cleaned on a regular basis.

  • Beer Stone: All beer contains calcium which is present from the grains used in the brewing process. It is an important natural material in draft systems in that as it oxidizes it coats the internal parts of the beer lines and equipment. The beer stone will continue to build if the system is not cleaned properly or regularly and can cause drawing problems if it begins to flake off. Beer stone is present if one can see a brownish color on the faucet or inner wall of the beer line, or tobaccolike flakes in the beer.

It is recommended that you purchase Perlick’s Pump Type Cleaning Kit. It is equipped with an adapter that attaches directly to the faucet shank, jar with pump, cleaning solution, faucet brush and spanner wrench.

Cleaning the draft beer system will help to eliminate the buildup of the following materials:

  • Bacteria: Beer is an excellent food for bacteria (none of which is harmful). Proper conditions may begin the growth of bacteria in draft beer and on the beer faucet. By regular cleaning, we prevent this bacterial buildup and maintain the quality of the draft beer. Greenish or yellowish colored material on the faucet may indicate bacterial growth.

Cleaning the Cabinet

Use a mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Never use a scouring pad or abrasive cleanser. Note: An industrial strength, commercial cleaner can be used to clean the outside of painted cabinets.

  • Yeast: All domestic draft beers contain a small amount of yeast which remains in the beer from the

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 7 of the Perlick DC90ACLT user manual — ➠
Page 7 · click to enlarge
Page 7

Pouring a Perfect Glass of Beer ArctiCold Draft Dispenser

Perlick DC90ACLT — Pouring a Perfect Glass of Beer ArctiCold Draft Dispenser diagram (page 7)
Fig. 6 · Pouring a Perfect Glass of Beer ArctiCold Draft Disp…

Start with a clean glass. Place the glass at a 45° angle, one inch below faucet. Do not let the glass touch the faucet. Open the faucet all the way.

reached half full, gradually bring the glass to the upright

➠

Perlick DC90ACLT — ➠ diagram (page 7)
Fig. 7

Let the remaining beer run straight down the middle of the glass. This ensures proper release of CO2 by producing a 3⁄4” to 1” foam head.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 8 of the Perlick DC90ACLT user manual — Wiring Diagrams ArctiCold Draft Dispenser
Page 8 · click to enlarge
Page 8

Wiring Diagrams ArctiCold Draft Dispenser

Perlick DC90ACLT — Wiring Diagrams ArctiCold Draft Dispenser diagram (page 8)
Fig. 8 · Wiring Diagrams ArctiCold Draft Dispenser

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 9 of the Perlick DC90ACLT user manual — PUMP
Page 9 · click to enlarge
Page 9

Glycol Loop Diagrams ArctiCold Draft Dispenser

PUMP

TUBE

TUBE

IN TUBE

IN TUBE

REFRIG. DECK

CABINET

GLYCOL

TANK

HEAT EXCHANGER

EVAPORATOR

FIN COIL

FLASH CHILL/FIN COIL CIRCUIT

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 10 of the Perlick DC90ACLT user manual — Glycol Level
Page 10 · click to enlarge
Page 10

Preventative Maintenance ArcticCold Draft Dispenser

Cleaning the Condenser

Pump Motors

The condensing coil should be inspected before each operation and cleaned if necessary. The condensing coil can be accessed by removing the louvered cover located on the customer side of the cabinet. The coil can be adequately cleaned with a vacuum, stiff bristled brush, or forced air. Please use care to ensure that the fins of the condenser are not bent or damaged.

Sleeve-bearing pump motors should be oiled at least once per year, (see figure A).

Casters

The casters should be greased at least once every 6 months. This may be required more often if the unit is used in dusty environments. There is a grease fitting located on each caster.

Glycol Level

The glycol system should be checked before each operation to ensure an adequate level. The glycol reservoir can be accessed by removing the lou- vered cover on the refrigeration deck. The reservoir is located at the right rear of the deck, (see figure A). Remove the sponge insulation and unscrew the cover. While using a mirror, ensure the glycol level is at the visible seam inside the reservoir located approximately 2" below the threads. Contact the Perlick Corporation for proper glycol solution if needed.

43 1/16” 53 3/8”

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Show 4 more labels / short text on this page
92 3/4” · 26 1/2” · 24 3/4” · 91”
Page 11 of the Perlick DC90ACLT user manual — Preventative Maintenance ArcticCold Draft Dispenser
Page 11 · click to enlarge
Page 11

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 12 of the Perlick DC90ACLT user manual — Preventative Maintenance ArcticCold Draft Dispenser
Page 12 · click to enlarge
Page 12
  • 8300 West Good Hope Road
  • Milwaukee, WI 53223
  • Phone 414-353-7060
  • Fax 414-353-7069 Toll Free 800-558-5592
  • E-Mail: Perlick@<a href="http://Perlick.com" rel="nofollow noopener" target="_blank">Perlick.com</a>
  • <a href="http://www.Perlick.com" rel="nofollow noopener" target="_blank">www.Perlick.com</a>

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Perlick DC90ACLT

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Perlick DC90ACLT

Be the first to ask — other owners or our team will answer.

Original document

Perlick DC90ACLT manual PDF

12 pages·951 KB·Beverage Dispenser·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…