EN
Pentax logo
Official user manual

Pentax QL-17

28 pages·1012 KB·Digital Camera·PDF·ENDEFRITNLJA
Pentax QL-17
Table of Contents 18 sections How to Use Your · 17/19 · Mercury Battery Loading · Battery Checking I n case of Canonet GUI 17 · … ShowHide
Page 1 of the Pentax QL-17 user manual — How to Use Your
Page 1 · click to enlarge
Page 1
Pentax QL-17 — How to Use Your diagram (page 1)
Fig. 1 · How to Use Your

How to Use Your

17/19

English Edition

Page 2 of the Pentax QL-17 user manual — How to Use Your
Page 2 · click to enlarge
Page 2
Pentax QL-17 — How to Use Your diagram (page 2)
Fig. 2 · How to Use Your

Focusing Lever Selftimer Lever Shutter Speed Ring AUTOMATIC/MANUAL Aperture Ring ASA Film Speed Indicator Window Automatic EE Mark

Flash Socket Safety Cover Film Rewind Crank Film Plane Indicator Accessory Shoe

Frame Counter Shutter Release Button Cable Release Socket Film Advance Lever

Focusing Ring Viewfinder Window

Page 3 of the Pentax QL-17 user manual — How to Use Your
Page 3 · click to enlarge
Page 3
Pentax QL-17 — How to Use Your diagram (page 3)
Fig. 3 · How to Use Your

Blue Lamp Battery Check Button Viewfinder Eyepiece Film Transport Indicator Film Wound-up Indicator Mercury Battery Compartment Tripod Socket

Film Rewind Button Bulb Exposure Setting Lever Film Speed Setting Lever Simple Exposure Symbols

* Exclusive to G-III 17 model. 2

Page 4 of the Pentax QL-17 user manual — Mercury Battery Loading
Page 4 · click to enlarge
Page 4
Pentax QL-17 — Mercury Battery Loading diagram (page 4)
Fig. 4 · Mercury Battery Loading

Mercury Battery Loading

Before using your Canonet G-III, load it with the mercury battery.

Insert the battery on the tab in the compartment. • Be sure the mercury battery is inserted only in the correct direction.

Replacing Battery When replacing the mercury bat- tery, open the cover of the mer- cury battery compartment and pull out the tab. The battery can then be easily removed. • When the camera will not be used for long period, remove the battery.

To open cover of the battery com- partment, insert fingernail in open slot, sliding cover in direction of arrow. By using a slight pull out- ward, the cover will hinge open.

  • A 1.3v M20 (#625) mercury battery should be used—equivalent to Mallory PX-625, Eveready EPX625. Press cover to close.
Page 5 of the Pentax QL-17 user manual — Battery Checking I n case of Canonet GUI 17
Page 5 · click to enlarge
Page 5
Pentax QL-17 — Battery Checking I n case of Canonet GUI 17 diagram (page 5)
Fig. 5 · Battery Checking I n case of Canonet GUI 17

Battery Checking I n case of Canonet GUI 17

! n case of Canonet G-IH 19

Turn the automatic/manual aperture ring,

In case of Canonet G-III 19 Look through the viewfinder; then press the battery check button. If the exposure indicator inside the viewfinder positions in the blue zone, the battery has sufficient power. Otherwise, it should be replaced.

releasing it from " A " position, and set it for manual control of aperture. In this case, any f/stop can be set.

In case of Canonet G-III 17 Press the battery check button (colored red). If the blue lamp lights up, the battery has sufficient power. Otherwise, the battery should be replaced.

  • The battery check button will not light up at temperatures of -15°C(5°F) or under. Camera will work, however, if the battery has sufficient power.
  • The Canonet G-III 17 has no blue zone.
Page 6 of the Pentax QL-17 user manual — Film Loading
Page 6 · click to enlarge
Page 6
Pentax QL-17 — Film Loading diagram (page 6)
Fig. 6 · Film Loading

Film Loading

Canon's Exclusive Quick-Loading (QL) mecha- nism in the Canonet G-III accepts any standard 35mm film roll in cartridge. When loading new film, always avoid direct sun- light.

Open the cover fully. When the back cover is opened, the QL cover opens simultaneously. Face the film cartridge as illustrated in line drawing inside back cover, and insert it into the cartridge compartment. Push crank back to its normal position.

To release the latch of the back cover, raise the film rewind crank, and pull it all the 5 way up.

Page 7 of the Pentax QL-17 user manual — Close the back cover completely. 6
Page 7 · click to enlarge
Page 7
Pentax QL-17 — Close the back cover completely. 6 diagram (page 7)
Fig. 7 · Close the back cover completely. 6

Lay the tip of the film leader above the "amber" film set mark.

Bring down the QL cover to hold the film in place by closing the back cover.

Look through the sprocket window to see if the film is correctly engaged with the sprocket,

The QL cover automatically opens and closes with the back cover, Do not touch the QL cover.

if the film is sagging, turn the film rewind crank clockwise.

Close the back cover completely. 6

Page 8 of the Pentax QL-17 user manual — Pre-Settings
Page 8 · click to enlarge
Page 8
Pentax QL-17 — Pre-Settings diagram (page 8)
Fig. 8 · Pre-Settings

Pre-Settings

Wind the film advance lever three or four times until it stops. The first frame is now automatically in position.

Checking Correct Film Loading The film is properly loaded and advanced if the film transport indicator flickers when you wind the film advance lever.

Checking Proper Winding Film (GIII 17) The film is wound up if the color of the film wound-up indicator turns red. The indicator turns white when the shutter is released. 7

Page 9 of the Pentax QL-17 user manual — Pre-Settings
Page 9 · click to enlarge
Page 9
Pentax QL-17 — Pre-Settings diagram (page 9)
Fig. 9 · Pre-Settings

Film Speed Setting Immediately after loading film, be sure to set the ASA film speed scale in the proper position by pressing the notched film speed setting lever with your fingernail, matching the proper film speed number with the index of the ASA film speed indicator window.

less sensitive. The ASA 200 film is better for shooting at low light level, than the ASA 100 film.

The higher the film speed number, the more sensitive the film; the lower it is, the

Page 10 of the Pentax QL-17 user manual — Automatic Electric Eye Photography
Page 10 · click to enlarge
Page 10
Pentax QL-17 — Automatic Electric Eye Photography diagram (page 10)
Fig. 10 · Automatic Electric Eye Photography

Automatic Electric Eye Photography

For Automatic Electric Eye photography, set the aperture ring at "A" position.

Shutter Speed Adjustment Turn the shutter speed ring, and match the film speed setting lever with the simple

The EE mechanism is fully coupled to the ASA film speed, the shutter speed and the aperture.

exposure symbol of either sunny ,cloudy

or indoor .With ASA 100 film for example, the shutter speeds are set at 1/500

sec. for sunny ,1/125 sec. for cloudy

and 1/30 sec. for indoor

Page 11 of the Pentax QL-17 user manual — Automatic Electric Eye Photography
Page 11 · click to enlarge
Page 11
Pentax QL-17 — Automatic Electric Eye Photography diagram (page 11)
Fig. 11 · Automatic Electric Eye Photography

While looking through the viewfinder, turn the focusing lever. The subject is in focus when the double image merges into one precise image in the center of the viewfinder.

Out of focus In focus

Focusing

Page 12 of the Pentax QL-17 user manual — Automatic Electric Eye Photography
Page 12 · click to enlarge
Page 12
Pentax QL-17 — Automatic Electric Eye Photography diagram (page 12)
Fig. 12 · Automatic Electric Eye Photography

Checking the Exposure Indicator Point the camera at the subject and check the position of the exposure indicator inside the viewfinder. Press the shutter button if the indicator is inside the proper exposure range.

  • If the indicator points to the under exposure warning mark, turn the shutter speed ring clockwise until the indicator moves to the proper exposure range, or use Canolite D or other flash units.
  • If the indicator points to the over exposure warning mark, turn the shutter speed ring counterclockwise until the indicator moves to the proper exposure range, or use an ND filter.
  • The shutter cannot be released if the exposure indicator is either over or under 11 the exposure warning mark.
Page 13 of the Pentax QL-17 user manual — Automatic Electric Eye Photography
Page 13 · click to enlarge
Page 13
Pentax QL-17 — Automatic Electric Eye Photography diagram (page 13)
Fig. 13 · Automatic Electric Eye Photography

Compose the Picture within the Frame. The field-of-view which will appear on the film can be seen within the rectangular frame.

Press the Shutter Button gently to snap picture.

Page 14 of the Pentax QL-17 user manual — Automatic Flash Photography—Using Canolite D
Page 14 · click to enlarge
Page 14
Pentax QL-17 — Automatic Flash Photography—Using Canolite D diagram (page 14)
Fig. 14 · Automatic Flash Photography—Using Canolite D

Automatic Flash Photography—Using Canolite D

The Canolite D is an optional electronic flash unit with direct contact exclusively designed for the Canonet G-III. There is absolutely no necessity for worrying about guide numbers. Night or indoor photography is now as easy as daylight photography using the 'Canolite D.

By simply attaching the Canolite D, the camera, while set at "A", is switched over to the automatic flash control circuit, and the proper f/stop corresponding to the shoot- ing distance is automatically set.

Page 15 of the Pentax QL-17 user manual — Automatic Flash Photography—Using Canolite D
Page 15 · click to enlarge
Page 15
Pentax QL-17 — Automatic Flash Photography—Using Canolite D diagram (page 15)
Fig. 15 · Automatic Flash Photography—Using Canolite D
  • Power Source: Two 1.5v alkaline AA batteries.
  • Size: 26 x 57 x 82 mm (1" x 2-1/4" x 3-1/4")
  • Weight: 115 grams (4 oz.)

Check the Exposure Indicator in the View- finder.

  • When it is within the proper exposure range, press the shutter release button.
Page 16 of the Pentax QL-17 user manual — Automatic Flash Photography—Using Canolite D
Page 16 · click to enlarge
Page 16
Pentax QL-17 — Automatic Flash Photography—Using Canolite D diagram (page 16)
Fig. 16 · Automatic Flash Photography—Using Canolite D
  • If the exposure indicator is within the red mark, the subject is too far or too close. Adjust focusing distance until indicator shows the proper exposure.
Page 17 of the Pentax QL-17 user manual — Automatic Flash Photography—Using Canolite D
Page 17 · click to enlarge
Page 17
Pentax QL-17 — Automatic Flash Photography—Using Canolite D diagram (page 17)
Fig. 17 · Automatic Flash Photography—Using Canolite D

Press the Shutter Button gently to snap picture.

B With the Canolite D, any shutter speed can be used.

Page 18 of the Pentax QL-17 user manual — Using Conventional Flash Units
Page 18 · click to enlarge
Page 18
Pentax QL-17 — Using Conventional Flash Units diagram (page 18)
Fig. 18 · Using Conventional Flash Units

Using Conventional Flash Units

The Canonet G-III has a socket for con- ventional type flash untis. Attach flash unit to the accessory shoe of the camera, and connect the cord of the flash unit to the flash socket of the camera.

Select correct blue number (14, 20, 28)* engraved on the aperture ring, matching with guide number of flash unit. With flash unit, set shutter speed at 1/30 sec. With electronic flash unit, any shutter speed can be used.

Page 19 of the Pentax QL-17 user manual — Using Conventional Flash Units
Page 19 · click to enlarge
Page 19
Pentax QL-17 — Using Conventional Flash Units diagram (page 19)
Fig. 19 · Using Conventional Flash Units
  • Do not use flash bulb (or unit) with following types of film because it does not couple properly.
  • In flash photography using a conventional electronic flash unit or flash bulb when the proper f/stop is set according to the guide number, there is a heavy drain on the mercury battery. Therefore, be sure to return the aperture ring to "A" position after shooting.

Flash bulb of guide number 14 with ASA 25 film, guide number 20 with ASA 800, and guide number 28 with ASA 400 or higher speeds,,

  • When the subject is too far or too close, shutter button cannot be depressed.
Page 20 of the Pentax QL-17 user manual — Manual Control of Aperture
Page 20 · click to enlarge
Page 20
Pentax QL-17 — Manual Control of Aperture diagram (page 20)
Fig. 20 · Manual Control of Aperture

Manual Control of Aperture

For manual control of aperture, release aper- ture ring from "A" position. The shutter speed and f/stop can be freely set for achiev- ing specialized technical effects. With the Canonet G-III, special effects in high key or low key can be obtained in the same manner as with high-grade cameras.

  • In manual exposure control, the position of the exposure indicator i s in the upper red mark.
Page 21 of the Pentax QL-17 user manual — Using Self-timer
Page 21 · click to enlarge
Page 21
Pentax QL-17 — Using Self-timer diagram (page 21)
Fig. 21 · Using Self-timer

Using Self-timer

The Canonet G-III has a built-in self-timer. To operate the self-timer, turn the self-timer lever in the direction of the arrow until it stops. The shutter will be released approxi- mately 10 seconds after the shutter button has been pressed.

  • The self-timer also operates when taking pictures with flash units.
  • If the self-timer lever is set, do not return it to normal position. It is automatically returned, after the picture is snapped.
Page 22 of the Pentax QL-17 user manual — Bulb Exposure
Page 22 · click to enlarge
Page 22
Pentax QL-17 — Bulb Exposure diagram (page 22)
Fig. 22 · Bulb Exposure

Bulb Exposure

Bulb exposure is used when taking pictures with long time exposures.

Set the shutter speed ring at "B" position, at the same time, pressing down on the bulb setting lever.

Release the aperture ring manually from "A" to the desired f/stop.

Page 23 of the Pentax QL-17 user manual — Bulb Exposure
Page 23 · click to enlarge
Page 23
Pentax QL-17 — Bulb Exposure diagram (page 23)
Fig. 23 · Bulb Exposure

Press the shutter button gently. The shutter will remain open as long as the shutter button is pressed and will close when the shutter button is released.

  • When an extended time exposure is being made, use the Canon Release, and tripod, to avoid blurred pictures.
Page 24 of the Pentax QL-17 user manual — Film Rewinding
Page 24 · click to enlarge
Page 24
Pentax QL-17 — Film Rewinding diagram (page 24)
Fig. 24 · Film Rewinding

Film Rewinding

When the film reaches the end, and the film advance lever stops, rewind the film into the cartridge as soon as possible. Be sure not to open the back cover before rewinding. Otherwise, the entire roll will be exposed, and ruined since the film will be exposed within the camera.

Raise the film rewind crank, turning it in the direction of the arrow, until the film is completely rewound in the cartridge.

To rewind, press in the rewind button.

Page 25 of the Pentax QL-17 user manual — Film Rewinding
Page 25 · click to enlarge
Page 25
Pentax QL-17 — Film Rewinding diagram (page 25)
Fig. 25 · Film Rewinding

Watch the film transport indicator, and stop rewinding when red and white lines cease to flicker.

Film Removing Open the back cover by pulling up the rewind crank fully, and remove the film cartridge.

Page 26 of the Pentax QL-17 user manual — Canonet G-III 19
Page 26 · click to enlarge
Page 26
Pentax QL-17 — Technical Data diagram (page 26)
Fig. 26 · Technical Data

Technical Data

Canolite D : Exclusive electronic flash unit designed for use with Canonet G-III with direct contact for cordless type. When per- forming flash photography, it is not necessary to worry about guide numbers or to calculate f/stops, Automatic setting of proper f/stop is possible as the EE circuit is coupled to the shooting distance. Canolite D is powered by two 1.5v alkaline AA batteries. Flash-Auto Mechanism for Other Flash Units :

CanonetG-III 17 Type : 35mm lens shutter type camera with Electric Eye. Picture Size : 24mm X 36mm Lens : Canon Lens 40mm F1.7. 6-element 4- component construction, with four newly designed glasses. Spectra coated in am- ber and purple. Viewfinder : Viewfinder combined with range-

Aperture openings coupled to shooting dis- tance at guide numbers 14, 20, 28 (m) with ASA 100. Shutter button is locked when it is outside the coupling range. Film Loading : Canon-developed QL (Quick Loading) mechanism. Accepts any stand- ard 35mm film in cartridge. Film Advance : Single-stroke 127°. Film trans-

finder, bright frame with automatic paral- lax correction, aperture scale, exposure in- dicator and over/under exposure warning marks. EE Mechanism : Built-in exposure meter with CdS cell for fully automatic exposure con- trol. Shutter speed priority system. ASA 25 to 800 (DIN 15 to 30). With ASA 100 film, EV 3.5 (f/1.7 at 1/4 sec.)-EV 17 (f/16 at 1 /500 sec.). Powered by one 1.3v M 20 ( # 625) mercury battery. Battery checker built in. Manual Control of Aperture : Possible at any desired f/stop by releasing EE mechanism. Shutter : Between-the-shutter. Shutter speeds

port and wound-up indicators built in. Frame Counter : Resets automatically. Size : 120 X 75 X 60mm (4-3/4" X 3" X 2-3/8") Weight : 620 grams (1 Ib. 5-7/8 oz.).

Canonet G-III 19

Similar to G-III 17 with the following ex- ceptions. Lens: Canon Lens 45mm F 1.9 5-element 4-component construction. Spectra coated in amber, purple and magenta. EE Mechanism : With ASA 100 film, EV 3.8 (f/1.9at1/4sec.)-EV17(f/16at1/500sec). SSI With no film wound-up indicator and blue

from 1/4 to 1/500 sec. and B. Automatically sets aperture, self-cocking combined film/ shutter wind, self-timer, X synchronization. Flash Contact : Accessory shoe with direct contact exclusive for Canolite D and con- ventional flash socket.

lamp built in. Subject to alterations.

Page 27 of the Pentax QL-17 user manual — Accessories
Page 27 · click to enlarge
Page 27
Pentax QL-17 — Accessories diagram (page 27)
Fig. 27 · Accessories

Accessories

Lens Hood 4 Canolite D Flash J-3 Canon Release 30 Canon Release 50

  • Filter 48 mm (Y1, Y3, O1, G1, R1, UV, ND-4, ND-8 Skylight, CCA 4, 8, 12, CCB 4, 8, 12)
  • Gadget Bag IV
  • Hard Case for Canonet G-III
Page 28 of the Pentax QL-17 user manual — Canon
Page 28 · click to enlarge
Page 28
Pentax QL-17 — Canon diagram (page 28)
Fig. 28 · Canon

Canon

PUB. TIE1003L 0 2 7 5 M 0 5 PRINTED IN T A I W A N R.O.C.

Ask about the Pentax QL-17

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Pentax QL-17

Be the first to ask — other owners or our team will answer.

Original document

Pentax QL-17 manual PDF

28 pages·1012 KB·Digital Camera·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…