PLP-602
PLP-601R Automatic Self-leveling Laser
PLP-602R Automatic Self-leveling Laser
PENTAX Industrial Instruments Co.,Ltd. 2-5-2 Higashi-Oizumi / Nerima-ku,Tokyo 178-0063,Japan Tel.+81 3 5905 1222 / Fax +81 3 5905 1225
Total Construction Solutions · Automatic Self-leveling Laser · Automatic Self-leveling Laser



The following items are intended to prevent possible injury to the user or other people and/or damage to the instrument. These safety precautions are important to the safe operation of this product and should be observed at all times.
Items indicated by this indication are precautions which, if ignored, could result in death or serious injury.



The instrument should not be stored or used in extreme temperatures or job on a place subject to rapid change of temperature. (Refer to the ambient temperature range) The instrument may not function properly if used out of the ambient temperature range.


Put into the carrying for storage and place in a dry area not subject to vibration, dust or high moisture.

When storage and usage temperatures are widely different, leave the instrument in the case until it can adjust to the surrounding temperature.


The detector (option) may react to the Laser beam and further react to the Fluorescent lamp, Site lamp, modulated light or an electric wave (in or near the airport etc.) and so correct measurement is sometimes not performed near these places. In these cases, please measure again after stopping or cutting these modulated light or wave etc.

The instrument should be transported or carried carefully to avoid impact or vibration.


The instrument should be stored in the carrying case and packed with cushioning material and handled with care as ‘Fragile’.

Check the ‘check and adjustment of the datumpoint’of page 35 in this manual and be sure to check to see if error exists before the instrument is used. After the instrument has been stored a long time or it has suffered an impact or vibration, be sure to check to see if trouble exists before use. If any trouble exists, adjust or have it repaired.


Be sure to observe the items in the instruction manual for proper use of the instrument.

Please replace attached batteries with new ones before you work because their voltage may be low.


The instrument (PLP-601 / PLP-602 /PLP-601R / PLP-602R)
D type battery (PLP-601 / PLP-602)
Charger (PLP-601R / PLP-602R)
Rechargeable Ni-MH battery built in the body (PLP-601R / PLP-602R)




LCD Display Illumination Switch
Buzzer Switch Accuracy Switch

Gently set down the carrying case so that its cover is upward. Unlatch and open the case while pushing the latch lock. Remember how the instrument is placed in the case before removing it.

Set down the carrying case and open the cover Gently put the instrument into the case Close the case and secure the latch
Latch

Turn the detaching knob for battery cap counterclockwise and remove the cap from the instrument. Insert 4 pcs D type batteries into the battery box according to its (+) and (-) marks. (PLP-601 / PLP-602) While holding the instrument with one hand,push the battery cap into the battery box and attach it by turning the knob clockwise.

LS6 Detector Slide the battery cover while pushing its mark and remove it. Insert the accumulated dry battery into the battery holder according to its (+) and (-) marks. Slide the battery cover to reinsert it.
Accumulated Dry Battery (6F22)
Rear View of LS6
Battery Cover

Remaining battery display lamp
Off level display lamp
BATTERY
MODE
CHECK POWER
ON ON
OFF OFF
2.2 Role of keys
(1) Power supply key
Pushing power supply key begins the automatic self-leveling. The off level display lamp blinks in red during activating the leveling. The blink interval becomes longer gradually as the leveling comes near to completion. The color of the off level display lamp turns to green when the leveling is completed, a rotor begins to rotate and then a laser beam is emitted horizontally. The lamp (green) is turned of about 5 seconds later after the leveling completion.
Off level display lamp
MANU MANU AL AL MODE MODE
BATTER TERY Y CHECK CHECK PO POWER WER
OFF OFF

Off level display lamp
The consumption status of a battery can be confirmed by the remaining battery display lamp when the battery check key is pressed after turning on the power supply. The remaining battery display lamp is turned off about 15 seconds later after the battery check key is pressed.
MANU MANU AL AL MODE MODE
BATTER TERY Y CHECK CHECK PO POWER WER
OFF OFF
Remaining battery display lamp
Turning on 3 green lamps
Workable enough.
Turning on 2 green lamps
Remaining capacity is little. Prepare the spare battery.
Turning on 1 green lamp
Battery is to be replaced.
Blink of 1 red lamp
Replace the battery.
Turning on 1 red lamp
Battery check key

When the Auto/manual change key is being pressed for more than 2 seconds, the manual mode display lamp is turned on in red. The automatic self-leveling begins and the automatic self-leveling function stops after completion of automatic leveling. During the manual mode, the laser beam is emitted even if the instrument is tilted largely (out of correction area). When the Auto/manual change key is pressed again, the manual mode display lamp is turned off, the manual mode is reset and returns to normal function.
Manual mode display lamp
MANU MANU AL AL MODE MODE
BATTER TERY Y CHECK CHECK PO POWER WER
OFF OFF
Auto/manual change key

Manual mode display lamp
Push the power supply key while pushing the Auto/Manual change key. Manual mode display lamp and off level display lamp blink in red a few seconds and tell that the rotation is switched to 600 rpm. The switched rotation speeds is memorized even if power supply is turned off.
Off level display lamp
MANU MANU AL AL MODE MODE
BATTER TERY Y CHECK CHECK PO POWER WER
OFF OFF
Turn off the power supply and then push the power supply key while pressing the battery check key to return to 300 rpm.
MANU MANU AL AL MODE MODE
BATTER TERY Y CHECK CHECK PO POWER WER
OFF OFF
Auto/manual change key · Battery check · Power supply key

Off level display lamp turns on in red as warning display and rotation of rotor and emission of laser beam stop under following situation.
Off level display lamp
MANU MANU AL AL MODE MODE
BATTER TERY Y CHECK CHECK PO POWER WER
OFF OFF
(1) When the instrument is tilted more than ± 5.7° (± 10%) then
power supply is turned on Turn off the power supply and install the instrument horizontally (within ± 5.7°) and turn on the power supply again. (2) When some shock is added to the instrument while at work
Turn off the power supply and turn on the power supply again. • If the work is to be continued, perform this procedure after resetting the laser beam at the “reference mark”.
(3) When, status that the automatic self-leveling function does not
become stable continues for about 3’after power supply is turned on Turn off the power supply and turn on the power supply again. But warning is displayed farther, change the setting place of instrument or stop the construction machines which may be the cause of vibraton.

[Arranging the tripod] Prepare the normal tripod for Level instrument. The dome head type and elevation type tripod for Level instrument can be used.
[Selection of the place to set up the tripod] Be sure to select a place where the job will not be interrupted and the instrument can be set to have almost same distance to each point to be measured.

Nearly horizontal · Extraction

[Setting up the tripod] For an extension tripod, adjust the legs to a suitable length and secure the leg clamps. Spread the legs to a proper extent for the tripod head to be nearly level and push them into the ground. Should the tripod head be off level, adjust it by expanding the legs accordingly.

[Mounting on the tripod] Mount the instrument on the tripod head and while supporting the instrument with one hand, secure it using the tripod center screw.

Instrument · Tripod head · Center screw

[Installing the rod adapter LA6] LS6 detector Mount the instrument on the rod adapter so that the guide pin of the rod adapter is inserted into the guide hole in the back of the detector. Tighten the attaching screw of the rod adapter into the detector.
Rod Adapter · Fixing screw · Detector

[Starting the operation] Press the power supply key. Automatic self-leveling function works and leveling begins automatically.When leveling is completed, the rotor begins to rotate and emits invisible laser beam.
display lamp Off level display lamp
MANU MANUAL AL MODE MODE Auto/Manual
BATTER TERY Y CHECK CHECK PO POWER WER
OFF OFF
Manual mode · change key · Power supply key

[Power switch] Push the power switch to turn on the power to the detector. Pushing the power switch again turns off the power.

[Selecting the reference level detecting accuracy] Push the detection accuracy selection switch to select the needed detection accuracy.
High accuracy detection: To be selected for detecting the reference level with accuracy.
Low accuracy detection: To be selected if high accuracy is not needed or when stable reference level cannot be obtained due to slight vibration at job site.
High accuracy · Low accuracy

[ON or OFF of the beam reception buzzer] Push the beam reception buzzer switch to select either the buzzer sounding or silenced.

[Illuminating the display] Push the illumination switch to illuminate the display. Pushing the switch again turns off the illumination.


[Detecting the reference level] At the measuring point, set the position of the detector nearly to the height of the beam emitting aperture of the instrument. Position the detector where the buzzer sound (or the beam reception display appears) by directing the detecting display nearly toward the instrument and moving the detector up and down. Move the detector up and down again according to the beam reception display (or the buzzer) and obtain the reference level.
Move the detector down as it is positioned high. The buzzer sound beeps at short intervals.
This is the reference position. The buzzer sound beeps continuously.
Move the detector up as it is positioned low. The buzzer sounds lasting beeps intermittently.

[Direct marking] After the reference level has been detected, mark a line along the detector’s index, or its top or bottom end.
[Plain rod marking] After the reference level has been detected, mark a line along the plain rod’s top or bottom end.
[Plain rod marking] After the reference level has been detected, mark a line along the plain rod’s top or bottom end.

[Reading the staff] After the reference level has been detected, read the staff, using the index on the rod adapter.


[Stains on the main body] Brush dust off and wipe off moisture with tissue paper. Clean off any stains with a soft, dry cloth. Excessive stains should be removed with a soft cloth soaked in a water diluted neutral detergent and squeezed dry. Do not use benzine, thinner, gasoline or chemicals.

[Stains on the glass surface] Brush dust off. Gently wipe off stains with a silicone cloth or a cleaning cloth for eye glass lenses. Excessive stains should be wiped off with soft cotton cloth impregnated with a cleaning liquid for eye glass lenses.


[Handling the battery] If the instrument is not to be used for a long time, be sure to remove the batteries from the instrument and the detector and store them.

leakage

[Check] Set up the instrument on the tripod halfway between two walls or pillars about 40m away so that the ‘X side’of the instrument faces the ‘Wall A’and level it. Operate the instrument and turn on the power to the detector.(use the detection accuracy initially set.) Mark the reference point detected for both walls. (A,B) Arrange a pair of target plates (with the same scale) and fix them to the walls (A and B) so that the center values of the target plates coincide with the reference point marks. Loosen the center screw of the tripod to turn the instrument 180 for the ‘X side’to face the ‘Wall B’and tighten the center lock screw again for the instrument to be leveled again.

Over view · X side · (Keypad)

Read the target plates on the walls (A,B) to detect the reference points. If the readings of the target plates differ less than ± 5 mm, the instrument needs not to be adjusted. If more than ± 5 mm, proceed to the following (Adjustment) procedure.
Appr. 20m Appr. 20m
Wall A Wall B X side in 1 X side in 5
Target · Detector

Rotor Display Content Checking point
Display lamps are Battery capacity Replace with fresh not turned on. is low. batteries or charge battery Incorrect battery Check the polarity insertion. of the batteries.
Lamp turns on. Instrument’s tilt Turn off the power exceeds auto leveling supply and reset the area.(± 5.7°) instrument level Instrument is tilt (± 5.7°) and turn on largely by any cause. again. After power supply Turn off the power turns on, unstable supply and turn on state of auto again. self-leveling function Turn off the power continues supply and turn on approx.3 min. again. NOTE*
Lamp & lamp Defect of instrument Turn off the power blink mutually itself. supply and turn on again.If the lamps blink farther, instrument need to be repaired.
* NOTE: • When the operation is continued, set the laser beam on the reference mark and perform it.
Manual mode display lamp:
Off level display lamp:
BATTER TERY Y CHECK CHECK PO POWER WER
OFF OFF
Does not rotate

Rotor Display Content Checking point
Can rotate Cannot detect Battery capacity Replace with fresh is low. battery. Incorrect battery Check the polarity insertion. of the batteries.
Can rotate Battery indicator Battery capacity Replace with fresh blinks is low. battery.
Detector LS6

Operation time: 24 hours on manganese battery (PLP-601/PLP-602) 48 hours on alkaline battery (PLP-601/PLP-602) 18 hours on Rechargeable Ni-MH battery (PLP-601R/PLP602R)
Auto power off: Power supply: Approx.10 min.

To assure compliance with the Safety Standard 21 CFR, Chapter I. Subchapter J.The U.S. bureau of Radiological Health requires the following information to be provided to the user:
diode radiating at 635nm ± 15 nm. B. Radiant power
This laser product is designed and built to radiate a maximum average radiant power of 10µ W as scanning beam during functional operation.The user may be subject to this radiation as a scanned beam while the rotor is rotating until such time that the instrument is turned off. • For a period of less than 10 seconds during the operation the user may be subjected to this radiation.
‘This laser product conforms to the provisions of 21 CFR 1040.10 and 1040.11.For a class 2 laser product.’ Located on the surface of the base of top-handle. B. Caurion Label
‘Laser beam, do not look into the laser beam source directly.’ Located near to exit aperture, facing upward.







PENTAX Industrial Instruments Co.,Ltd.
2-5-2 Higashi-Oizumi Nerima-ku,Tokyo 178-0063,Japan
Tel.+81 3 5905 1222 Fax +81 3 5905 1225 E-mail:international@piic.pentax.co.jp Website:www.pentax.co.jp/piic/survey

Member symbol of the Japan Surveying Instruments Manufacturers’ Association representing the high quality surveying products.
Printed in Belgium · Total Surveying Solutions
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.