Instruction/ maintenance manual of the product WCSI-4 Pelco
Go to page of 12
WCS1-4 Environmental Power Supply C561M-D (11/03) ® INST ALLA TION/OPERA TION.
2 C561M-D (11/03) IMPORT ANT SAFEGUARDS AND W ARNINGS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Installation should be done only by qualified service personnel and conform to all local codes.
C561M-D (11/03) 3 DESCRIPTION The WCS1-4 is a mutliple power supply designed for indoor or outdoor applications and is ideal for use with cameras, domes, and integrated positioning systems such as Spectra ® and Esprit ® . The WCS1-4 is capable of powering up to four units and can handle pan/tilt, heater , blower , and camera operation.
4 C561M-D (11/03) INST ALLA TION MOUNTING INSTRUCTIONS To mount the power supply directly to a wallboard, wall, or concrete refer to Figures 1 through 3 and do the following: 1. Remove the retaining screw from the door latch of the WCS1-4 power supply .
C561M-D (11/03) 5 FUSE INST ALLA TION The WCS1-4 power supply is shipped from the factory with a 1.6-amp fuse installed for 100/120 V AC input power . T o use input power of 230 VAC, change the 1.
6 C561M-D (11/03) OUTPUT WIRING To install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do the following: 1. Refer to T able A and determine the output connection needed for your camera, dome, or positioning system.
C561M-D (11/03) 7 CABLE CONNECTIONS AND REQUIREMENTS Table A. Wiring Distances The following are the recommended maximum distances to wire the WCS1-4 to a Spectra III or Esprit positioning system. To determine the correct voltage tap: 1. Pick the unit type.
8 C561M-D (11/03) MAINTENANCE There are no user -serviceable parts except for the fuse. If the transformer in the WCS1-4 does not work properly , the entire environmental power supply needs to be returned to the factory for repair . Refer to the Wa rranty and Return Information for instructions on returning the WCS1-4.
C561M-D (11/03) 9 SPECIFICA TIONS ELECTRICAL Input V oltage: Selectable 100, 120, 230 V AC, 50/60 Hz via the Primary Line Input connector strip Output V oltage/Power: Selectable 24 V AC (T ap A), 26 VAC (T ap B), or 28 VAC (T ap C) at 100 V A via the Secondary Output T ap’ s connector strip Fusing: One fuse.
10 C561M-D (11/03) Figure 5. WCS1-4 Dimension Drawing NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES. 6.50 (16.51) 5.63 (14.30) 4.50 (11.
C561M-D (11/03) 11 W ARRANTY AND RETURN INFORMA TION W ARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.
An important point after buying a device Pelco WCSI-4 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco WCSI-4 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco WCSI-4 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco WCSI-4 you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco WCSI-4 will certainly help you make a decision on the purchase.
If you already are a holder of Pelco WCSI-4, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco WCSI-4.
However, one of the most important roles played by the user manual is to help in solving problems with Pelco WCSI-4. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco WCSI-4 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center