Instruction/ maintenance manual of the product CM8500 Pelco
Go to page of 16
® PELCO • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • (800) 289-9100 or (1-559) 292-1981 FAX (800) 289-9150 or (1-559) 292-3827 Breakout Panels for V A6000 Series Switcher and CM8500 Matrix S.
T ABLE OF CONTENTS Section Page 1.0 W ARNINGS ........................................................................................................................................ 1 2.0 SCOPE ........................................................
Pelco Manual C842M (9/96) 1 INSTALLATION/OPERATION MANUAL BREAKOUT PANELS FOR VA6000 SERIES SWITCHER AND CM8500 MATRIX SYSTEM 1.0 W ARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes.
2 Pelco Manual C842M (9/96) 2.0 SCOPE The information contained within this manual covers the installation and operation of the Alarm Breakout Panels for the V A6000 Series Switcher and the Alarm, W iretron and Relay Breakout Panels for the CM8500 Matrix system.
Pelco Manual C842M (9/96) 3 ALARM BREAKOUT P ANEL (PCB9000617) Mounting Plate J1 J2 Keyed connectors PCB Layout 25-PIN Cable 15-PIN Cable CABLE ASSEMBLIES WIRING SCHEMA TIC Figure 1.
4 Pelco Manual C842M (9/96) Figure 2. Installation Configuration and Pin Mapping for 4/8 Alarm Inputs-V A6000 Alarm Breakout Panel Alarm Pin-outs 1-8/V A6000 Rear Panel Connector ALM # 15-Pin Female Conn.
Pelco Manual C842M (9/96) 5 Figure 3. Installation Configuration and Pin Mapping for 12/20 Alarm Inputs-V A6000 Alarm Breakout Panel Alarm Pin-outs 1-16/CM8500 Rear Panel-P4 ALM # 25-Pin Female Conn.
6 Pelco Manual C842M (9/96) WIRING SCHEMA TIC CABLE ASSEMBL Y PCB LA YOUT ALARM BREAKOUT P ANEL (PCB9000582) Mounting Plate Figure 4. Alarm Breakout Panel Assembly Information–CM8500 Series.
Pelco Manual C842M (9/96) 7 Alarm Pin-outs 1-16/CM8500 Rear Panel-P4 ALM # Pin Number Alarm Com The table below lists the pin-out relationship between the alarm panel header , J1, and P4 on the CM8500 for the first 16 alarms. The pattern serves equally well for alarms 17-32: P4 becomes P3 and the listed alarms go from 17-32 instead of 1-16.
8 Pelco Manual C842M (9/96) Figure 6. Wiretron Breakout Panel Assembly Information–CM8500 Series WIRING SCHEMA TIC RIBBON CABLE WIRETRON BREAKOUT P ANEL (PCB9000583) Mounting Plate.
Pelco Manual C842M (9/96) 9 The table below lists the pin-out relationship between the wiretron panel header , J1, and P5 on the CM8500 for the first 16 wire control positions. The pin mappings serve equally well for wire controls 17-32: P5 becomes P6 and the listed WIR numbers go from 17-32 instead of 1-16.
10 Pelco Manual C842M (9/96) Figure 8. Wiretron Breakout Panel Assembly Information–CM8500 Series WIRING SCHEMA TIC Mounting Plate RELA Y BREAKOUT P ANEL (PCB9000581) PCB LA YOUT RIBBON CABLE ASSEMB.
Pelco Manual C842M (9/96) 11 Figure 10. Rack Panel Mounting Plate Dimensions Figure 9. Installation Configuration for the CM8500 Wiretron Breakout Panel.
12 Pelco Manual C842M (9/96) 1 ... ... 1 1 ... 2 ... 2 ... ... 3 3 4 ... ... 4 2 ... 5 ... 5 ... ... 6 6 7 ... ... 7 3 ... 8 ... 8 ... ... 9 9 10 ... ... 10 4 ... 1 1 ... 1 1 ... ... 12 12 13. ... ... 13 5 ... 14 ... 14 ... ... 15 15 16 ... ... 16 6 .
Pelco Manual C842M (9/96) 13 5.0 MODELS VA6008-APNL-2 VA6000 alarm breakout panel for up to 8 alarm inputs; 2-foot (.609 m) interconnecting ribbon cable supplied. VA6008-APNL-10 Same as VA6008-APNL-2, ex- cept 10-foot (3.048 m) intercon- necting ribbon cable.
14 Pelco Manual C842M (9/96) Pelco 3500 Pelco Way, Clovis, CA 93612-5699 (559) 292-1981 • (800) 289-9100 FAX (800) 289-9150 or (559) 292-3827 International customers call 1-559-292-1981 or FAX 1-559-348-1120 (Product specifications subject to change without notice.
An important point after buying a device Pelco CM8500 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco CM8500 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco CM8500 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco CM8500 you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco CM8500 will certainly help you make a decision on the purchase.
If you already are a holder of Pelco CM8500, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco CM8500.
However, one of the most important roles played by the user manual is to help in solving problems with Pelco CM8500. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco CM8500 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center