Instruction/ maintenance manual of the product C613M-A (5/05) Pelco
Go to page of 28
® Endura ™ SP04-140 Dual-Input V ideo Encoder INSTALLATION C613M-A (5/05).
2 C613M-A (5/05) Contents Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description .
C613M-A (5/05) 3 List of Illustrations 1 Product Serial Number Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2 SP04-140 Desktop Placement .
4 C613M-A (5/05) Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
C613M-A (5/05) 5 Description The SP04-140 is a special version of the single-input NET5301T video encoder . It is a high-performance, dual-stream, dual-input video encoding unit. Its main function is to convert live analog video from two cameras into dual MPEG-4 video streams.
6 C613M-A (5/05) PRODUCT SERIAL NUMBER LABEL PLACEMENT Product serial number labels help Pelco’ s Product Support identify your system and its factory configuration in case the SP04-140 or its components require service. A label citing your product’ s serial number is attached to the bottom panel of the SP04-140.
C613M-A (5/05) 7 Equipment Placement and Rack Mounting The SP04-140 can be placed on a flat surface, such as a desktop; mounted to a wall; or mounted into an equipment rack. DESKTOP MOUNTING To place the SP04-140 on a flat surface, such as a desktop: 1.
8 C613M-A (5/05) W ALL MOUNTING The SP04-140 can be mounted to a wall using the optional WM5001-4U wall mount system. Y ou can mount up to four SP04-140, NET5301T , and NET5301R units, in any combination, in a fully expanded WM5001-4U (one WM5001-4U with up to three WM5001-4UEXP expansion units).
C613M-A (5/05) 9 RACK MOUNTING Any combination of SP04-140, NET5301T , and NET5301R units can be mounted together in the optional RK5000PS-5U rack mount kit, up to 12 units. Each unit plugs directly into a power connector in the rack and is powered by the rack.
10 C613M-A (5/05) PELCO BADGE ORIENTATION The Pelco badge on the front panel of the SP04-140 can be rotated in quarter turns. If you install the unit on a flat surface, the Pelco badge will be turned the wrong way . To rotate the Pelco badge: 1. Use the Pelco badge rotation sticker that came with the unit.
C613M-A (5/05) 11 Connections Familiarize yourself with the SP04-140 rear panel before connecting any equipment to the unit. Figure 8. SP04-140 Rear Panel CONNECTING V IDEO INPUTS The SP04-140 offers two analog video inputs.
12 C613M-A (5/05) Before installing the SP04-140, make sure the distance from the unit to the video device is less than the maximum distance for the coaxial cable.
C613M-A (5/05) 13 CONNECTING AUDIO The SP04-140 supports half-duplex, bidirectional audio (one direction at a time). It transmits audio and video signals simultaneously . This lets you control a loudspeaker or other audio equipment, such as a door intercom system, at the monitored location.
14 C613M-A (5/05) CONNECTING A PTZ DEVICE, RELAY , AND ALARMS The SP04-140 incorporates a 16-pin terminal block to support the following: • PTZ device, such as a dome camera, using the Pelco D proto.
C613M-A (5/05) 15 CONNECTING A PTZ DEVICE (PELCO D PROTOCOL) NOTE: To connect a Coaxitron PTZ device, refer to Connecting Video Inputs The SP04-140 supports camera control using Pelco D protocol (RS-422) for a PTZ device. Y ou can connect only one serial PTZ device to a video encoder .
16 C613M-A (5/05) Refer to T able C when installing the PTZ device. It lists the serial port settings that the SP04-140 supports. T able C. Serial Port Options and Defaults CONNECTING A RELAY DEVICE The SP04-140 has an output for triggering an external device.
C613M-A (5/05) 17 CONNECTING ALARMS The SP04-140 offers three alarm inputs for external signaling devices, such as door contacts or motion detectors. Each encoder supports either all normally open or all normally closed devices. If your installation requires mixed devices, install another SP04-140, NET5301T , or a NET5301R video decoder .
18 C613M-A (5/05) Figure 15 illustrates the wiring configuration for supervised alarm inputs. Figure 15. Supervised Alarm Input Wiring Unsupervised Alarms When an alarm is configured as an unsupervised alarm, the SP04-140 only triggers an alarm when the normal alarm state (open or closed) changes.
C613M-A (5/05) 19 Alarm Connections Figure 18 shows how to wire the video encoder to an alarm (refer to T able B for the specific connector pin assignments). Figure 18. Connecting Alarms CONNECTING POWER The SP04-140 video encoder is designed to operate from either a 12 VDC or a 24 V AC power supply .
20 C613M-A (5/05) Use T able E to help identify the necessary wire gauge and maximum cable distance. This table applies to two-conductor solid copper wire. (Reduce distance by 10% for stranded copper wire.) These maximum distances are based on a maximum allowable voltage drop of 10%.
C613M-A (5/05) 21 Operation Refer to the WS5000 operation manual for details on how to access and configure the SP04-140 video encoder . FRONT PANEL INDICATORS Figure 20. SP04-140 Front Panel Pelco badge (power) The Pelco badge glows blue when the unit has power .
22 C613M-A (5/05) CONFIGURATION/RESET BUTTON Use the recessed configuration/reset button at the top of the front panel to access the following modes: T able F . Configuration/Reset Button Functions and Indicators To access one of these modes: 1. Use a probe or paper clip to press and hold the configuration/reset button .
C613M-A (5/05) 23 T roubleshooting If the following instructions fail to solve your problem, contact Pelco Product Support at 1-800-289-9100 or 1-559-292-1981 for assistance. Access the properties windows for the SP04-140 video encoder on the WS5050 workstation (refer to the WS5000 operation manual).
24 C613M-A (5/05) Specifications MODEL NUMBER SP04-140 Dual-input network video server that encodes video, audio, and control data for transmission over an IP network SUPPLIED ACCESSORIES Mating Conn.
C613M-A (5/05) 25 VIDEO ACTIVITY DETECTION Zones 3 plus background zone Zone T ypes Any shape, user -definable in 16 x 16 pixel blocks Sensitivity Adjustable AUXILIARY INTERF ACES Serial Pelco D (RS-.
26 C613M-A (5/05) ST ANDARDS/ORGANIZA TIONS • Pelco is a member of the MPEG-4 Industry Forum • Pelco is a member of the Universal Plug and Play (UPnP) Forum • Pelco is a member of the Universal .
PRODUCT WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
® W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
An important point after buying a device Pelco C613M-A (5/05) (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco C613M-A (5/05) yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco C613M-A (5/05) - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco C613M-A (5/05) you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco C613M-A (5/05) will certainly help you make a decision on the purchase.
If you already are a holder of Pelco C613M-A (5/05), but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco C613M-A (5/05).
However, one of the most important roles played by the user manual is to help in solving problems with Pelco C613M-A (5/05). Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco C613M-A (5/05) along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center