Instruction/ maintenance manual of the product C561M-F Pelco
Go to page of 12
INST ALLA TION/OPERA TION WCS1-4 Environmental Power Supply C561M-F (8/06).
2 C561M-F (8/06) Important Safeguards and W arnings 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Installation should be done only by qualified serv ice personnel and conform to all local codes.
C561M-F (8/06) 3 Description The WCS1-4 is a single power supply designed for indoor or outdoor applicatio ns and is ideal for use with cameras, domes, and integrated positioning systems such as Spectra ® and Esprit ® . The WCS1-4 power supply has one fused output and is capable of handling up to 4 amps (100 VA) of total load.
4 C561M-F (8/06) Installation MOUNTING INSTRUCTIONS T o mount the power supply directly to a wallboard, wall, or concre te refer to Figure 1 through 3 and do the following: 1. Remove the retaining screw from the door latch of the WCS1-4 power supply .
C561M-F (8/06) 5 FUSE INSTALLATION The WCS1-4 power supply is shipped from the fa ctory with a 1.6-amp fuse installed for 100/120 V AC input power . T o use input power of 240 V AC, c hange the 1.
6 C561M-F (8/06) OUTPUT WIRING T o install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do the following: 1. Refer to T able A and determine the output connection needed for your camera, dome, or positioning system.
C561M-F (8/06) 7 CABLE CONNECTIONS AND REQUIREMENTS T able A. Wiring Distances The following are the recommended maximum distances to wire the WCS1-4 to a Spectra III or Esprit positioning system. T o determine the correct voltage tap: 1. Pick the unit type.
8 C561M-F (8/06) Maintenance There are no user -serviceable parts except for the fuse. If the transformer in the WCS1-4 does not work properly , the entire environment al power supply needs to be retu rn ed to the factory for repair . Refer to the W arranty and Return Information for instructions on returning the WCS1-4.
C561M-F (8/06) 9 Specifications ELECTRICAL Input V oltage Selectable 100, 120, 240 VAC, 50/60 Hz via the Primary Line Input connector strip Output V oltage/Power Selectable 24 VAC (T ap A), 26 VAC (T ap B), or 28 V AC (T ap C) at 100 VA via the Secondary Output T ap’ s connector strip Fusing One fuse.
10 C561M-F (8/06) Figure 5. WCS1-4 D imensi on Draw ing The materials used in the manufacture of this document and its compo nents are compliant to the requirements of Directive 2002/95/EC.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, witho ut charge, any mer c handise proved defective in ma terial or wo rkmanship for a period of one year after th e date of shipment.
W orldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
An important point after buying a device Pelco C561M-F (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco C561M-F yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco C561M-F - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco C561M-F you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco C561M-F will certainly help you make a decision on the purchase.
If you already are a holder of Pelco C561M-F, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco C561M-F.
However, one of the most important roles played by the user manual is to help in solving problems with Pelco C561M-F. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco C561M-F along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center