EN
Peerless Industries logo
Official user manual

Peerless Industries SUA746PU

29 pages·1.4 MB·TV Mount·PDF·ENDEITNLJA
Peerless Industries SUA746PU
Table of Contents 13 sections ISSUED: 10-24-11 SHEET #: 095-9364-1 · WALL CONSTRUCTION HARDWARE REQUIRED · Table of Contents · Installation to Single Wood Stud Wall · … ShowHide
Page 1 of the Peerless Industries SUA746PU user manual — ISSUED: 10-24-11 SHEET #: 095-9364-1
Page 1 · click to enlarge
Page 1
Installation and AssemblyPeerless Ultra-Thin Articulating Mount for 32" to 46"* Flat Panel Displays
ModelSUA746PU
Peerless Industries SUA746PU — ISSUED: 10-24-11 SHEET #: 095-9364-1 diagram (page 1)
Fig. 1
  • *Display Compatibility Requirements
  • Depth of display must be less than 2".
  • The depth of this mount (1.27") may not provide suffi cient space for proper ventilation on some displays. Please refer to the manufacturer's requirements for mounting your display before installation.
  • The display must have a fl at mounting surface, or the mounting holes need to be on the furthest back surface of the display.
  • Input/Output connection must be properly oriented to accommodate mounting 1.27" from the wall.

Max UL Load Capacity:

60 lb (27.2 kg)

  • 2300 White Oak Circle
  • Aurora, Il 60502
  • (800) 865-2112
  • Fax: (800) 359-6500
  • <a href="http://www.peerlessmounts.com" rel="nofollow noopener" target="_blank">www.peerlessmounts.com</a>

ISSUED: 10-24-11 SHEET #: 095-9364-1

Page 4 of the Peerless Industries SUA746PU user manual — Installation to Single Wood Stud Wall
Page 4 · click to enlarge
Page 4

Installation to Single Wood Stud Wall

  • Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
  • Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder is highly recommended.
  • Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).

Use a stud fi nder to locate the edges of the stud. Use of an edge-to-edge stud fi nder is highly recommended. Based on their edges, draw a vertical line down the stud’s center. Measure 4.8" (122 mm) left or right from stud's center to determine center of display mounting plate. Place wall arm (A) on wall as template, level, and mark the center of two mounting holes. Top mounting hole will be 6.66" above the center of display mounting plate as shown in fi gure 1.1.

Drill two 5/32" dia. holes to a minimum depth of 2.5". Secure wall arm (A) to wall with two wood screws (C) as shown in fi gure 1.2. For cable management option, install cable anchor (I) to bottom mounting hole with wood screw (C). NOTE: Be sure arrow is pointing up when mounting wall arm (A) to wall as shown in fi gure 1.1. Level, then tighten all fasteners.

Insert two fastener caps (H) into wall plate mounting holes.

Peerless Industries SUA746PU — Installation to Single Wood Stud Wall diagram (page 4)
Fig. 2 · Installation to Single Wood Stud Wall
Page 5 of the Peerless Industries SUA746PU user manual — INCORRECT CORRECT
Page 5 · click to enlarge
Page 5

Installation to Solid Concrete or Cinder Block

  • When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
  • Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
  • Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

Place wall arm (A) on wall as template, level, and mark the center of two mounting holes. Top mounting hole will be 6.66" above the center of display mounting plate as shown in fi gure 1.1 on page 4. Drill two 5/16" dia. holes to a minimum depth of 2.5". Insert anchors (D) into holes fl ush with wall as shown. Secure wall arm (A) to wall with two wood screws (C) as shown in fi gure 1.3. For cable management option, install cable anchor (I) to bottom mounting hole with wood screw (C). NOTE: Be sure arrow is pointing up when mounting wall arm assembly (A) to wall as shown in fi gure 1.1. Level, then tighten all fasteners.

D

Drill holes and insert anchors (D).

D

Place plate (A) over anchors (D) and secure with screws (C).

Insert two fastener caps (H) into wall plate mounting holes.

  • Tighten screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.

Tighten all fasteners.

  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Always attach concrete expansion anchors directly to load-bearing concrete.

SOLID CONCRETE CINDER BLOCK

  • Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other fi nishing material. If mounting to concrete surfaces covered with a fi nishing surface is unavoidable (not evaluated by UL), the fi nishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).

D

C H

INCORRECT CORRECT

CUTAWAY VIEW

wa platll econcretewa platll econcrete plaster/ dry wallplaster/ dry wall

concrete surface

Page 6 of the Peerless Industries SUA746PU user manual — Installing Adapter Brackets to Display
Page 6 · click to enlarge
Page 6

Installing Adapter Brackets to Display

Peerless Industries SUA746PU — Installing Adapter Brackets to Display diagram (page 6)
Fig. 3 · Installing Adapter Brackets to Display
  • Tighten screws so display brackets are fi rmly attached to display. Do not tighten with excessive force. Overtightening can cause stress damage to screws, greatly reducing their holding power and possibly causing screw heads to become detached. Tighten to 40 in.
  • lb (4.5 N.M.) maximum torque.
  • If screws don't get three complete turns in the display inserts or if screws bottom out and bracket is still not tightly secured, damage may occur to display or product may fail.

To prevent scratching the display, set a cloth on a fl at, level surface that will support the weight of the display. Place display face side down. If display has obstructions on the back, remove them to allow the adapter brackets to be attached. Place adapter brackets (B) on back of display, align to holes, and center vertically on back of display as shown below. Attach the adapter brackets to the back of the display using the appropriate combination of screws, washers, and spacers, if required, as shown in steps 2-1 or 2-2.

Verify that all holes are properly aligned, and then tighten screws using allen wrench (G).

Peerless Industries SUA746PU — Installing Adapter Brackets to Display diagram (page 6)
Fig. 4 · Installing Adapter Brackets to Display
Page 7 of the Peerless Industries SUA746PU user manual — For Flat Back Display
Page 7 · click to enlarge
Page 7

For Flat Back Display

2-1 Begin with the shortest length screw, hand thread through washer, adapter bracket and spacer, if required, into display as shown below. If screw cannot make three full turns into the display and fi t snug into place, select a longer length screw from the baffl ed fastener pack. Repeat for remaining mounting holes, level brackets and tighten screws.

Peerless Industries SUA746PU — For Flat Back Display diagram (page 7)
Fig. 5 · For Flat Back Display
esscus u ll pg eh w tur atash ns in for r

If you have any questions, please call Peerless customer care at 1-800-865-2112.

Page 8 of the Peerless Industries SUA746PU user manual — Mounting and Removing Flat Panel Display
Page 8 · click to enlarge
Page 8

Mounting and Removing Flat Panel Display

WARNING • Always use an assistant or mechanical lifting equipment to safely lift and position the fl at panel displa • Be careful not to pinch fi ngers when opening and closing mount from the wall. • DO NOT operate or tilt arm assembly when safety latches are in unlocked position. Product may fail injury or damage to display. • Do not tighten safety/security screw (E) with excessive force. Overtightening can cause screw head t damaged making it diffi cult to remove. Tighten screws to 15 in•lb (1.7 N.M.) maximum torque.ys. and may cause o become Wall arm assembly (A) must be in closed position to Rotate safety latch with fl athead sc 3 hang display. install safety/security screw (E) thr into adapter bracket with phillips sc Rotate safety latch with fl athead screwdriver into to adapter plate as shown in detail unlocked position as shown in detail 1. DETAIL 1 SAFETY LATCH Hook adapter brackets (B) onto the center of wall arm assembly (A) adapter plate as shown in fi gure 3.1. B B DE A SAFETY DET LATCH fi g. 3.1
Page 9 of the Peerless Industries SUA746PU user manual — Roll Adjustment
Page 9 · click to enlarge
Page 9

Roll Adjustment

Peerless Industries SUA746PU — Roll Adjustment diagram (page 9)
Fig. 6 · Roll Adjustment

Adapter plate may be rolled +/- 5°. Roll locking screw may be tightened or loosened using 4 mm allen wrench (G). NOTE: Do not remove roll locking screw.

  • Do not tighten joint screws. Doing so may cause damage to screws, greatly reducing their holding power.

Cables may be routed using cable clip (J).

Slip cable clip (J) onto bottom of center joint as shown in fi gure 5.1 and secure cables to cable clip using cable tie (K) as shown in fi gure 5.2.

Secure cables to cable anchor (I) using cable tie (K) as shown below.

© 2011, Peerless Industries, Inc. All rights reserved. All other brand and product names are trademarks or registered trademarks of their respective owners.

Peerless Industries, Inc.

2300 White Oak Circle Aurora, Il 60502 www.peerlessmounts.com

Ask about the Peerless Industries SUA746PU

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Peerless Industries SUA746PU

Be the first to ask — other owners or our team will answer.

Original document

Peerless Industries SUA746PU manual PDF

29 pages·1.4 MB·TV Mount·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…