EN
Peerless Industries logo
Official user manual

Peerless Industries SA771PU

70 pages·11.7 MB·TV Mount·PDF·ENITNLJA
Peerless Industries SA771PU
Table of Contents 60 sections Models: SA771PU · ISSUED: 10-30-09 SHEET #: 095-9299-11 03-22-12 · WALL CONSTRUCTION HARDWARE REQUIRED · Table of Contents · … ShowHide
Page 1 of the Peerless Industries SA771PU user manual — ISSUED: 10-30-09 SHEET #: 095-9299-11 03-22-12
Page 1 · click to enlarge
Page 1
Installation and AssemblyUniversal Articulating Arm Wall Mount for 37" to 71" Flat Panel Displays

Models: SA771PU

Peerless Industries SA771PU — Models: SA771PU diagram (page 1)
Fig. 1 · Models: SA771PU
Max UL Load Capacity200 lb (90.7 kg)
  • 2300 White Oak Circle
  • Aurora, Il 60502
  • (800) 865-2112
  • Fax: (800)359-6500
  • <a href="http://www.peerless-av.com" rel="nofollow noopener" target="_blank">www.peerless-av.com</a>

ISSUED: 10-30-09 SHEET #: 095-9299-11 03-22-12

Page 3 of the Peerless Industries SA771PU user manual — E G F
Page 3 · click to enlarge
Page 3

Before you begin, make sure all parts shown are included with your product.

Peerless Industries SA771PU — Parts List diagram (page 3)
Fig. 2 · Parts List

Parts List

SA771PU Description Qty. Part # A wall arm assembly 1 095-P1994 B universal adapter bracket 1 095-P1635-1 C wood screws 4 520-1243 D concrete anchors 4 590-0321 E M10 x 15 mm socket head screw 2 520-9262 F wall plate cover 2 590-1325 G cable ties 16 590-1168 H 6 mm allen wrench 1 560-9716 I 5 mm allen wrench 1 560-9640 J rear cable cover 4 590-P1326 K front cable cover 4 590-P1327 L Panasonic extension bracket 2 095-P1623 M Sharp extension bracket 2 095-P1622 N 1/4-20 self tapping screws 4 520-1633 O M10 x 15 phillips screws 4 520-1305 P 5/32" allen wrench 1 560-9646

Parts may appear slightly different than illustrated.

B C D

Peerless Industries SA771PU — B C D diagram (page 3)
Fig. 3

E G F

Peerless Industries SA771PU — E G F diagram (page 3)
Fig. 4
Page 4 of the Peerless Industries SA771PU user manual — Parts List
Page 4 · click to enlarge
Page 4
Peerless Industries SA771PU — Parts List diagram (page 4)
Fig. 5 · Parts List
Page 5 of the Peerless Industries SA771PU user manual — 1/4-20 X 17 MM SCREWS WALL PLATE
Page 5 · click to enlarge
Page 5

Optional Horizontal Adjustment of Wall Arm on Wall Plate

Determine desired location of display center detailed in step 2.

Measure the distance from the center of wall arm (A) to desired display center. Loosen four 1/4-20 x 17 mm screws using 5 mm allen wrench (I). Slide wall arm assembly 4-1/2" to the left or right as shown in fi gure 1.1. NOTE: Align bevels (dots) of slide plate with bevels (dots) of wall plate rails as shown in detail 1 then retighten 1/4-20 x 17 mm screws.

Do not adjust arm while display is attached.

Skip to page 6 for Wood Stud Installation. Skip to page 7 for Concrete and Cinder Block Installation.

1/4-20 X 17 MM SCREWS WALL PLATE

Peerless Industries SA771PU — 1/4-20 X 17 MM SCREWS WALL PLATE diagram (page 5)
Fig. 6
Page 6 of the Peerless Industries SA771PU user manual — CS = CENTER OF DISPLAY
Page 6 · click to enlarge
Page 6

Installation to Double-Stud Wall

  • Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
  • Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder is highly recommended.
  • Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).

Use a stud fi nder to locate the edges of the studs and draw a vertical line down the center of each stud. Determine and mark the desired display center on the wall. Place wall plate template (wall arm) on wall with top mounting slots 9" (229 mm) above desired display center as shown in fi gure 2.1. Level wall plate template (wall arm) on wall and mark center of four mounting holes making sure that the mounting holes are on the stud centerlines. Drill four 3/16" (5 mm) dia. pilot holes to a depth of 3" (76 mm). Attach wall arm (A) to wall using four wood screws (C) as shown in fi g. 2.2.

Level wall plate then tighten all fasteners.

Peerless Industries SA771PU — Installation to Double-Stud Wall diagram (page 6)
Fig. 7 · Installation to Double-Stud Wall

WOOD STUD

Peerless Industries SA771PU — WOOD STUD diagram (page 6)
Fig. 8

CS = CENTER OF DISPLAY

Page 7 of the Peerless Industries SA771PU user manual — SOLID CONCRETE
Page 7 · click to enlarge
Page 7

Installation to Solid Concrete or Cinder Block

  • When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
  • Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
  • Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

Determine and mark the desired display center on the wall. Place wall plate template (wall arm) on wall with top mounting slots 9" (229 mm) above desired display center as shown in fi gure 2.1 on page 6. Level wall plate template (wall arm) on wall and mark center of four mounting holes making sure that the mounting holes. Drill four 3/8" (10 mm) dia. pilot holes to a depth of 3" (76 mm). Insert anchors (D) into holes fl ush with wall as shown (right). Place wall arm over anchors and secure with 5/16 x 3" screws (C). Level, then tighten all fasteners.

D

Drill holes and insert anchors (D).

D C

Place plate (A) over anchors (D) and secure with screws (C).

  • Tighten screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Always attach concrete expansion anchors directly to load-bearing concrete.

Tighten all fasteners.

  • Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other fi nishing material. If mounting to concrete surfaces covered with a fi nishing surface is unavoidable (not evaluated by UL), the fi nishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).

SOLID CONCRETE

CINDER BLOCK

D

INCORRECT CORRECT

CUTAWAY VIEW

Show 6 more labels / short text on this page
concrete surface · concrete concrete · wall plate · wall plate · plaster/ dry wall · plaster/ dry wall
Page 8 of the Peerless Industries SA771PU user manual — SLOT
Page 8 · click to enlarge
Page 8

Installing Extension Brackets to Universal Adapter Brackets

Skip to step 3-1 on page 9 if not installing exten- sion brackets.

Peerless Industries SA771PU — Installing Extension Brackets to Universal Adapter Brackets diagram (page 8)
Fig. 9 · Installing Extension Brackets to Universal Adapter B…

Remove four 1/4-20 self-tapping screws to detach display brackets from universal adapter bracket (B) using 5 mm allen wrench (I) as shown.

1/4-20 SELFTAPPING SCREWS

HOLES

For 65" Panasonic Display:

SLOTS

Attach Panasonic extension brackets (L) through holes indicated to universal adapter bracket (B) with four 1/4-20 self-tapping screws using 5 mm allen wrench (I) as shown. Then secure with 1/4-20 self-tapping screws (N) through slots indicated.

N

SLOTS

HOLES

For 65" Sharp Display:

HOLE

M

Attach Sharp extension brackets (M) through holes indicated to universal adapter bracket (B) with two M5 fl athead screws using 5 mm allen wrench (I) as shown. Then secure with two 1/4-20 self-tapping screws (N) through slots indicated.

SLOT

N

Page 9 of the Peerless Industries SA771PU user manual — Installing Adapter Brackets to Display
Page 9 · click to enlarge
Page 9

Installing Adapter Brackets to Display

Peerless Industries SA771PU — Installing Adapter Brackets to Display diagram (page 9)
Fig. 10 · Installing Adapter Brackets to Display

Remove four 1/4-20 x .6" screws using 5 mm allen wrench (I) and loosen two 1/4-20 x 1.25" screws 1/2 turn to allow for display bracket adjustment.

To prevent scratching the display, set a cloth on a fl at, level surface that will support the weight of the display. Place display face side down and refer to display manufacturers instructions for removing obstructions from the back of the display. Adjust display brackets to align with display mounting holes.

Measure horizontal mounting hole pattern and choose fi xed stop-position from chart below.

Peerless Industries SA771PU — Installing Adapter Brackets to Display diagram (page 9)
Fig. 11 · Installing Adapter Brackets to Display
horizontal mounting hole pattern fixed stop-position 10-3/4" - 16-1/16" (273 - 408 mm)#1 15-1/16" - 21-9/16" (383 - 548 mm)#2 20-7/16" - 27-9/16" (519 - 700 mm)#3 26-1/16" - 32-9/16" (661 - 827 mm)#4
Page 10 of the Peerless Industries SA771PU user manual — DISPLAY BRACKETS
Page 10 · click to enlarge
Page 10
  • Tighten screws so display brackets are fi rmly attached to display. Do not tighten with excessive force. Overtightening can cause stress damage to screws, greatly reducing their holding power and possibly causing screw heads to become detached. Tighten to 40 in.
  • lb (4.5 N.M.) maximum torque.
  • If screws don't get three complete turns in the display inserts or if screws bottom out and bracket is still not tightly secured, damage may occur to display or product may fail.

Select the screws from the baffl ed fastener pack that best fi t your display and secure to display following step 3-4 or 3-5 on page 11.

Verify that all holes are properly aligned, then tighten screws using a phillips screwdriver.

CENTER DISPLAY BRACKETS VERTICALLY ON BACK OF DISPLAY

DISPLAY

Peerless Industries SA771PU — CENTER DISPLAY BRACKETS VERTICALLY ON BACK OF DISPLAY diagram (page 10)
Fig. 12

DISPLAY BRACKETS

Y Y

"Y" dimensions should be equal. NOTE: "X" dimensions should be equal.

Page 11 of the Peerless Industries SA771PU user manual — DISPLAY
Page 11 · click to enlarge
Page 11

For Flat Back Display

Begin with the shortest length screw, hand thread screw through multi-washer and display brackets (B) into display as shown below. Screw must make at least three full turns into the mounting hole and fi t snug into place. Do not over tighten. If screw cannot make three full turns into the display, select a longer length screw from the baffl ed fastener pack. Repeat for remaining mounting holes, level display brackets and tighten screws. NOTE: Spacers may not be used, depending upon the type of display.

DISPLAY

MULTI-WASHER

SCREW

Skip to step 3-6.

B

For Bump-out or Recessed Back Display

Begin with the longest length screw, hand thread screw through multi-washer, display brackets (B) and spacer in that order into display as shown below. Screw must make at least three full turns into the mounting hole and fi t snug into place. Do not over tighten. If screw cannot make three full turns into the display, select a shorter length screw from the baffl ed fastener pack. Repeat for remaining mounting holes, level display brackets and tighten screws.

DISPLAY

MULTI-WASHER SPACER

SCREW

B

3-6 1/4-20 x 1.25" SCREWS

Center display brackets horizontally and vertically on back of display. Tighten two 1/4-20 x 1.25" screws. Reinstall four 1/4-20 x .6" screws using 5 mm allen wrench (I) into appropriate fi xed-stop position from chart on page 9.

1/4-20 x .6" SCREWS

Page 12 of the Peerless Industries SA771PU user manual — VESA 200 x 200 or VESA 200 x 100 Mounting Pattern
Page 12 · click to enlarge
Page 12

VESA 200 x 200 or VESA 200 x 100 Mounting Pattern

Peerless Industries SA771PU — VESA 200 x 200 or VESA 200 x 100 Mounting Pattern diagram (page 12)
Fig. 13 · VESA 200 x 200 or VESA 200 x 100 Mounting Pattern

Remove four 1/4-20 x .6" screws using 5 mm allen wrench (I) and loosen two 1/4-20 x 1.25" screws 1/2 turn to allow for display bracket adjustment.

Remove four 1/4-20 self tapping screws to detach display brackets from outer mount holes of universal adapter bracket (B) using 5 mm allen wrench (I) as shown in fi gure 4.1. Reinstall four 1/4-20 self tapping screws to secure display brackets to inner set of mounting holes on universal adapter bracket (B) as shown in fi gure 4.2.

Peerless Industries SA771PU — VESA 200 x 200 or VESA 200 x 100 Mounting Pattern diagram (page 12)
Fig. 14 · VESA 200 x 200 or VESA 200 x 100 Mounting Pattern
Peerless Industries SA771PU — VESA 200 x 200 or VESA 200 x 100 Mounting Pattern diagram (page 12)
Fig. 15 · VESA 200 x 200 or VESA 200 x 100 Mounting Pattern

To prevent scratching the display, set a cloth on a fl at, level surface that will support the weight of the display. Place display face side down and place universal adapter bracket (B) onto display.

Peerless Industries SA771PU — VESA 200 x 200 or VESA 200 x 100 Mounting Pattern diagram (page 12)
Fig. 16 · VESA 200 x 200 or VESA 200 x 100 Mounting Pattern
Page 13 of the Peerless Industries SA771PU user manual — FIXED STOP POSITION #1 WITH
Page 13 · click to enlarge
Page 13

VESA 200 x 200 or VESA 200 x 100 Mounting Pattern (Continued)

4-2 SCREW

Align one display bracket with one set of display mounting holes.

Peerless Industries SA771PU — VESA 200 x 200 or VESA 200 x 100 Mounting Pattern (Continued) diagram (page 13)
Fig. 17 · VESA 200 x 200 or VESA 200 x 100 Mounting Pattern (C…

Begin with the shortest length screw, hand thread screw through multi-washer and display brackets into display as shown. Screw must make at least three full turns into the mounting hole and fi t snug into place. Do not over tighten. If screw cannot make three full turns into the display, select a longer length screw from the baffl ed fastener pack. Center display brackets vertically and tighten screws.

Slide universal adapter bracket to the opposite side and align second display bracket with second set of display mounting holes.

Peerless Industries SA771PU — VESA 200 x 200 or VESA 200 x 100 Mounting Pattern (Continued) diagram (page 13)
Fig. 18 · VESA 200 x 200 or VESA 200 x 100 Mounting Pattern (C…

Hand thread screws through multi-washer, display bracket, and spacer if used, into display as shown. Tighten all screws.

Tighten two 1/4-20 x 1.25" screws. Reinstall four 1/4-20 x .6" screws using 5 mm allen wrench (I) into fi xed-stop position 1 as shown in fi gure 4.4. 4-4

Center display brackets horizontally on back of display as shown in fi gure 4.3.

Peerless Industries SA771PU — VESA 200 x 200 or VESA 200 x 100 Mounting Pattern (Continued) diagram (page 13)
Fig. 19 · VESA 200 x 200 or VESA 200 x 100 Mounting Pattern (C…
Peerless Industries SA771PU — VESA 200 x 200 or VESA 200 x 100 Mounting Pattern (Continued) diagram (page 13)
Fig. 20 · VESA 200 x 200 or VESA 200 x 100 Mounting Pattern (C…

1/4-20 x .6" SCREWS fi g. 4.3

FIXED STOP POSITION #1 WITH

Page 14 of the Peerless Industries SA771PU user manual — Mounting Flat Panel Display
Page 14 · click to enlarge
Page 14
Peerless Industries SA771PU — Mounting Flat Panel Display diagram (page 14)
Fig. 21 · Mounting Flat Panel Display
  • Do not lift more weight than you can handle. Use additional man power or mechanical lifting equipment to safely handle placement of the display.
  • Do not tighten screws with excessive force. Overtightening can cause damage to mount. Tighten M10 x 15 mm screws ( E ) to 40 in.
  • lb (4.52 N.M.) maximum torque.

Mounting Flat Panel Display

5 For Universal Adapter Bracket: Hook M10 x 15 mm screws into keyslots of wall arm adapter plate (A) as shown fi gure 5.2.

For Dedicated PLP Plate (not evaluated by UL): Refer to PLP model instruction sheet for attachment of dedicated PLP plate to display. Install two M10 x 15 mm screws (provided with dedicated PLP plate) into top two holes of dedicated PLP plate leaving 1/4" of exposed thread as shown in fi gure 5.1.

Peerless Industries SA771PU — Mounting Flat Panel Display diagram (page 14)
Fig. 22 · Mounting Flat Panel Display

Insert two M10 x 15 mm screws (E) into bottom holes of adapter plate as shown in fi gure 5.3 or 5.4. Tighten all fasteners with 6 mm allen wrench (H). 5-1

Page 15 of the Peerless Industries SA771PU user manual — M8 X 40 MM
Page 15 · click to enlarge
Page 15

Adjustment of Flat Panel Display

  • M10 x 15 mm screws ( E ) must be securly tightened before changing orientation of wall arm assembly ( A ). Failure to lock adapter bracket can cause display to come off of mount.

FOR PORTRAIT OR LANDSCAPE DISPLAY ORIENTATION: Remove two M5 x 12mm screws, one M5 x 6mm screw and rotation block from top of tilt head as shown in top view and rear view. Gently grasp sides of display and rotate display into portrait or landscape position as shown in fi gure 6.1 and reinstall rotation block with two M5 x 12mm screws and one M5 x 6mm screw. NOTE: M5 x 6mm screw required in landscape orientation only.

ROTATION BLOCK

M5 X 6MM SCREWS

M5 X 12MM SCREWS

TOP VIEW

SCREWS M5 X 6MM

M5 X 12MM

SCREWS

ROTATION

BLOCK

REAR VIEW

TILT Adjustment: Adjust tension knob on side of mount to desired tension to enable tilt adjustment and balance your display size and weight. Push or pull from top or bottom of display to adjust tilt as shown. The tilt can be adjusted to a maximum of 10° forward or 5° backward. Retighten tension knob. NOTE: For larger displays, tension screw on opposite side of mount may need to be tightened using 5/32" allen wrench (P).

TENSION KNOB

ROLL Adjustment: Rotate display 5° clockwise or counter-clockwise, level display then tighten M5 x 10 mm roll screws using 5 mm allen wrench (I) as shown in detail 2.

M5 X 10 MM

FOR VERTICAL HEIGHT ADJUSTMENT: Tighten or loosen M8 x 40 mm screw to achieve ± 1" of vertical height adjustment as shown in detail 2.

SCREWS

CAUTION

  • Do not tighten screws with excessive force.
  • Be careful not to pinch fi ngers when opening and closing mount from the wall.

M8 X 40 MM

SCREW

DETAIL 2

Page 16 of the Peerless Industries SA771PU user manual — Cable Management
Page 16 · click to enlarge
Page 16

Cable Management

Peerless Industries SA771PU — Cable Management diagram (page 16)
Fig. 23 · Cable Management

Run power cable through top or bottom of arm (A) and signal cable(s) through other side of arm in order to avoid interference with the signal. Lock cables into place by snapping cable covers (J & K) onto mount as shown. Display may have to be moved for easy access.

Optional: If additional cable management is required route cable ties (G) through slots of arm (A) as shown in detail 3.

Peerless Industries SA771PU — Cable Management diagram (page 16)
Fig. 24 · Cable Management

Snap wall plate covers (F) to top and bottom of wall plate rails as shown. 9

Page 17 of the Peerless Industries SA771PU user manual — Arm Tension Adjustment
Page 17 · click to enlarge
Page 17

Arm Tension Adjustment

Peerless Industries SA771PU — Arm Tension Adjustment diagram (page 17)
Fig. 25 · Arm Tension Adjustment
  • Do not remove screw or loosen screw until it is no longer engaged with the mount. Doing so may cause the display to fall.
  • If screws become loose over time, tighten screws as necessary. Tighten screws to 50 in
  • lbs (5.6 N.m.) maximum torque.
  • If more or less tension is desired in the arm pivot points, do the following:
  • To increase tension, turn socket screw clockwise with 5 mm allen wrench ( I ). NOTE: Tighten screws to 50 in
  • lbs (5.6 N.m.) maximum torque.
  • To reduce tension, turn socket screw counter-clockwise with 5 mm allen wrench ( I ). NOTE: Do not turn more than half a turn.
Peerless Industries SA771PU — Arm Tension Adjustment diagram (page 17)
Fig. 26 · Arm Tension Adjustment

© 2012, Peerless Industries, Inc. All rights reserved. All other brand and product names are trademarks or registered trademarks of their respective owners.

Page 18 of the Peerless Industries SA771PU user manual — PUBLICADO: 10-30-09 HOJA #: 095-9299-11 03-22-12
Page 18 · click to enlarge
Page 18
Instalación y montajeSoportes de pared de brazo articulador para pantallas planas de 37" a 71"

Modelos: SA771PU

Peerless Industries SA771PU — Modelos: SA771PU diagram (page 18)
Fig. 27 · Modelos: SA771PU

Máxima Capacidad de Carga para UL: 200 lb (90.7 kg)

  • 2300 White Oak Circle
  • Aurora, Il 60502
  • (800) 865-2112
  • Fax: (800)359-6500
  • <a href="http://www.peerless-av.com" rel="nofollow noopener" target="_blank">www.peerless-av.com</a>

PUBLICADO: 10-30-09 HOJA #: 095-9299-11 03-22-12

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Peerless Industries SA771PU

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.