EN
Peerless Industries logo
Official user manual

Peerless Industries SA730P-S

29 pages·2.2 MB·TV Mount·PDF·EN
Peerless Industries SA730P-S
Table of Contents 30 sections Installation and Assembly: Articulating Wall Arm for 10" - 24" LCD screens · Models: SA730P, SA730P-S, D-LA-100, D-LA-100S · © U L US C · ISSUED: 05-09-05 SHEET #: 095-9224-9 12-05-09 · … ShowHide
Page 1 of the Peerless Industries SA730P-S user manual — ISSUED: 05-09-05 SHEET #: 095-9224-9 12-05-09
Page 1 · click to enlarge
Page 1

Installation and Assembly: Articulating Wall Arm for 10" - 24" LCD screens

Models: SA730P, SA730P-S, D-LA-100, D-LA-100S

Peerless Industries SA730P-S — Models: SA730P, SA730P-S, D-LA-100, D-LA-100S diagram (page 1)
Fig. 1 · Models: SA730P, SA730P-S, D-LA-100, D-LA-100S
  • Features:
  • Fits 10" - 24" LCD screens
  • Pivots and articulates in all directions, even around corners and cabinets
  • Frees up space by folding flat against the wall
  • Keeps electronic wires routed internally to reduce clutter Max UL Load Capacity: 25 lb (11.3 kg)

© U L US C

  • 3215 W. North Ave.
  • Melrose Park, IL
  • (800) 865-2112 or (708) 865-8870
  • Fax: (708) 865-2941
  • <a href="http://www.peerlessmounts.com" rel="nofollow noopener" target="_blank">www.peerlessmounts.com</a>

ISSUED: 05-09-05 SHEET #: 095-9224-9 12-05-09

Page 3 of the Peerless Industries SA730P-S user manual — B
Page 3 · click to enlarge
Page 3

Before you begin, make sure all parts shown are included with your product.

Parts List

D-LA-100S SA730P-S Description Qty. Part # Part # A wall arm assembly 1 095-P1639 095-4639 B concrete anchor 2 590-0320 590-0320 C #14 x 2.5" flat head wood screw 2 520-1202 520-2165 D M4 x 12 mm phillips screw 4 504-9013 504-2013 E M4 x 20 mm phillips screw 4 504-9020 504-2014 F retaining spacer 4 590-5005 590-5003 G 5 mm allen wrench 2 560-9640 560-9640 H plastic covers 2 590-P1322 590-4322 I fastener caps 2 590-1324 590-4324 J 8-32 x 1/4" phillips screw 2 520-1622 520-2622 K cable tie anchors 2 590-1290 590-1290 L cable ties 8 560-1756 560-1756 M #3 screwdriver bit (not shown) 1 560-0209 560-0209 N cord management clip 2 590-1264 590-2164

D-LA-100 SA730P

Parts may appear slightly different than illustrated.

B

E A

D

F

H

G

J

K

N

Page 4 of the Peerless Industries SA730P-S user manual — Installation to Wood Stud Wall
Page 4 · click to enlarge
Page 4

Installation to Wood Stud Wall

  • Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
  • Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is highly recommended.
  • Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations (not evaluated by UL).

Using a stud finder, locate and mark the edges of the wood stud used in mounting this product. Use of an "edge to edge" stud finder is highly recommended. Use a level to draw a vertical line down the center of the stud. Use wall plate as template to mark center of holes along the vertical line. The top mounting hole should be located 3.25" (83 mm) above the desired screen center as shown in figure 1.1. Drill two 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Attach wall arm assembly (A) to wall with two #14 x 2.5" flat head wood screws (C) using #3 phillips screwdrive bit (M) as shown in figure 1.2.

Insert two fastener caps (I) into wall plate mounting holes.

Peerless Industries SA730P-S — Installation to Wood Stud Wall diagram (page 4)
Fig. 2 · Installation to Wood Stud Wall
Page 5 of the Peerless Industries SA730P-S user manual — WALL PLATE
Page 5 · click to enlarge
Page 5

Installation to Solid Concrete and Cinder Block

  • When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
  • Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
  • Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

1 Use a level to draw a vertical line on mounting surface. Level and use wall plate as template to mark center of holes. The top mounting hole should be located 3.25" (83 mm) above the desired screen center as shown in figure 1.1 on page 4. Drill two 5/16" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (B) in holes flush with wall as shown right. Place wall arm (A) over anchors and secure with two #14 x 2.5" flat head wood screws (C) using #3 phillips screwdrive bit (M) as shown in figures 1.3. Make sure wall arm is level, and tighten all fasteners.

B

Drill holes and insert anchors (B).

A

B C

Place plate (A) over anchors (B) and secure with screws (C).

Insert two fastener caps (I) into wall plate mounting holes.

  • Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.

Tighten all fasteners.

  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Always attach concrete expansion anchors directly to load-bearing concrete.

SOLID CONCRETE

CINDER BLOCK

  • Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing material. If mounting to concrete surfaces covered with a finishing surface is unavoidable (not evaluated by UL), the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).

B

WALL PLATE

INCORRECT CORRECT

A

CUTAWAY VIEW

wa platll econcretew plaall teconcrete plaster/ dry wallplaster/ dry wall
Peerless Industries SA730P-S — WALL PLATE diagram (page 5)
Fig. 3

concrete surface

Page 6 of the Peerless Industries SA730P-S user manual — ADAPTER PLATE
Page 6 · click to enlarge
Page 6
  • If screws don't get three complete turns in the screen inserts or if screws bottom out and bracket is still not tightly secured, damage may occur to screen or product may fail.

Insert two M4 x 12 mm screws (D) into top two holes of screen, leaving approximately 1/4" of exposed thread. Hook screws onto keyslots of adapter plate as indicated in figures 2.1 and 2.2.

*For screens with a hole pattern in a pocket, spacers (F) go between adapter plate and screen.

*Note: If hole pattern is in a pocket, insert two M4 x 20 mm screws (E) with two retaining spacers (F) into top two holes of screen as indicated right.

F

D

FOR VESA ® 75 MOUNTING PATTERN:

FOR VESA 100 MOUNTING PATTERN:

Insert one M4 screw (D or E) through bottom hole of adapter plate as shown in figure 3.1.

ADAPTER PLATE

D or E

1/4"

Page 7 of the Peerless Industries SA730P-S user manual — CORD
Page 7 · click to enlarge
Page 7

Cord Management

Route cords through center of cord management clip (N). Next, attach cord management clip (N) to adapter plate using M4 screw (D or E) as shown in detail 1. Tighten all four fasteners.

DETAIL 1

D or E

N

Cords may also be routed using cable ties (L).

Attach cable tie anchor (K) to top or bottom of wall arm (A) using 1/4" phillips screw (J) as shown in figure 4.1.

Secure cords to top or bottom of wall arm (A) using cable ties (L) as shown in figure 4.2.

J

L K

CORD

A

Page 8 of the Peerless Industries SA730P-S user manual — Cord Management
Page 8 · click to enlarge
Page 8

Cords may also be routed using plastic covers (H).

Route cords inside arm slots of wall arm (A). Lock cords into place by snapping cord corvers onto mount as shown in figure 4.3. NOTE: Be sure arrow on inside of plastic covers (H) point toward screen as shown in detail 2.

Peerless Industries SA730P-S — Cord Management diagram (page 8)
Fig. 4 · Cord Management

Cables may also be secured to slot at bottom of wall plate using a cable tie (L) as shown below.

Page 9 of the Peerless Industries SA730P-S user manual — SOCKET SCREW
Page 9 · click to enlarge
Page 9

If more or less tension is desired in tilt mechanism, remove snap caps as shown in detail 3. Insert a flat head screw- driver into slot and pry cap away from tilt mechanism. To adjust tilt, tighten or loosen socket screw no more than half a turn using 5 mm allen wrench (G). To adjust roll, tighten or loosen 10-32 nylock nut.

WARNING • Do not remove screw or loosen screw until it is no longer engaged with the mount. Doing so may cause the scre to fall. • If screws become loose over time, tighten screws as necessary. Tighten screws to 50 in. • lb (5.6 N.M.) maximum torque.en YL

SOCKET SCREW

SLOT

DETAIL 3

Tension Adjustment

If more or less tension is desired in the arm pivot points, do the following:

  • To increase tension, turn tension screw(s) clockwise using 5 mm allen wrenchs ( G ). NOTE: Tighten screws to 50 in.
  • lb (5.6 N.M.) maximum torque.
  • To reduce tension, turn tension screw(s) couter-clockwise using 5 mm allen wrenchs ( G ). NOTE: Do not loosen more than half a turn.

SOCKET SCREW

SOCKET SCREW

© 2009 Peerless Industries, Inc. All rights reserved. Peerless is a registered trademark of Peerless Industries, Inc. All other brand and product names are trademarks or registered trademarks of their respective owners.

Ask about the Peerless Industries SA730P-S

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Peerless Industries SA730P-S

Be the first to ask — other owners or our team will answer.

Original document

Peerless Industries SA730P-S manual PDF

29 pages·2.2 MB·TV Mount·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…