EN
Peerless Industries logo
Official user manual

Peerless Industries PT660

34 pages·3.7 MB·TV Mount·PDF·ENITNLJA
Peerless Industries PT660
Table of Contents 34 sections Model: PT660, PWS421/BK · © U L US C · ISSUED: 02-05-09 SHEET #: 202-9272-4 04-12-10 · WALL CONSTRUCTION HARDWARE REQUIRED · … ShowHide
Page 1 of the Peerless Industries PT660 user manual — ISSUED: 02-05-09 SHEET #: 202-9272-4 04-12-10
Page 1 · click to enlarge
Page 1

Installation and Assembly: Universal Tilt Wall Mounts for 37" - 60" (94 - 152 cm) Flat Panel Screens

Model: PT660, PWS421/BK

© U L US C

D

:

Max Load Capacity200 lb (90.7kg)
Peerless Industries PT660 — D diagram (page 1)
Fig. 1
  • Features:
  • Universal mount fi ts screens with mounting hole patterns up to 29.06" W x 17.67" H (738 mm W x 449 mm H)
  • Screen held only 2.5" (64 mm) from wall for a discreet installation
  • Open wall plate design allows for greater wall and an array of cable management options
  • Universal tilt brackets easily hook onto the wall plate for fast installation
  • Adjustable up to 15° of forward tilt and up to -5° backward tilt for optimal viewing angle
  • One-touch tilt for effortless adjustment
  • Pre-tensioned universal tilt bracket allows for tilt angle adjustment in one easy motion.
  • Easy locking handle locks the screen position into place without the use of tools
  • Optional IncreLok feature offers fi xed tilts at -5°, 0°, 5°, 10°, 15° increments
  • Includes Sorted-For-You™ fastener packs for installation to wood studs, concrete and cinder block
  • Optional horizontal adjustment of up to 8" (203 mm) (depending on screen model) for perfect screen placement

ISSUED: 02-05-09 SHEET #: 202-9272-4 04-12-10

Page 4 of the Peerless Industries PT660 user manual — fi g. 1.2
Page 4 · click to enlarge
Page 4

Installation to Double Wood Stud Wall

  • Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
  • Tighten wood screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder is highly recommended.
  • Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations (not UL approved).

Use a stud fi nder to locate the edges of the studs. Use of an edge-to-edge stud fi nder is highly recommended. Based on their edges, draw a vertical line down each stud’s center. Place wall plate on wall as a template. The top mounting slots should be 2.5" (64 mm) above the desired screen center as shown in fi gure 1.1. Level plate, and mark the center of the four mounting holes. Make sure that the mounting holes are on the stud centerlines. Drill four 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Make sure that the wall plate is level, secure it using four #14 x 2.5" wood screws (DD) as shown in fi gure 1.2.

Skip to step 2.

Peerless Industries PT660 — Installation to Double Wood Stud Wall diagram (page 4)
Fig. 2 · Installation to Double Wood Stud Wall
Peerless Industries PT660 — Installation to Double Wood Stud Wall diagram (page 4)
Fig. 3 · Installation to Double Wood Stud Wall

fi g. 1.2

Page 5 of the Peerless Industries PT660 user manual — INCORRECT CORRECT
Page 5 · click to enlarge
Page 5

Installation to Solid Concrete or Cinder Block

  • When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifi cations. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
  • Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
  • Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components.

Make sure that wall plate (AA) is level, use it as a template to mark four mounting holes. The top mounting hole should be 2.5" (64 mm) above the desired screen center as shown in fi gure 1.1 on page 4. Drill four 5/16" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (EE) in holes fl ush with wall as shown (right). Place wall plate over anchors and secure with #14 x 2.5" screws (DD). Level, then tighten all fasteners.

EE

Drill holes and insert anchors (EE).

EE DD

  • Tighten screws so that wall plate is fi rmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.

Place plate (AA) over anchors (EE) and secure with screws (DD).

  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Always attach concrete expansion anchors directly to load-bearing concrete.
  • Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other fi nishing material. If mounting to concrete surfaces covered with a fi nishing surface is unavoidable (not evaluated by UL), the fi nishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).

Tighten all fasteners.

solid concrete cinder block

EE

INCORRECT CORRECT

CUTAWAY VIEW

DD

Show 6 more labels / short text on this page
concrete surface · concrete concrete · wall plate · wall plate · plaster/ dry wall · plaster/ dry wall
Page 6 of the Peerless Industries PT660 user manual — HANDLES FACE OUT
Page 6 · click to enlarge
Page 6

Attaching Tilt Brackets to Screen using Baffl ed Fastener Pack

Peerless Industries PT660 — Attaching Tilt Brackets to Screen using Baffl ed Fastener Pack diagram (page 6)
Fig. 4 · Attaching Tilt Brackets to Screen using Baffl ed Fast…
  • Tighten screws so adapter brackets are fi rmly attached. Do not tighten with excessive force. Overtightening can cause stress damage to screws, greatly reducing their holding power and possibly causing screw heads to become detached. Tighten to 40 in.
  • lb (4.5 N.M.) maximum torque.
  • If screws don't get three complete turns in the screen inserts or if screws bottom out and bracket is still not tightly secured, damage may occur to screen or product may fail.

To prevent scratching the screen, set a cloth on a fl at, level surface that will support the weight of the screen. Place screen face side down. Refer to screen manufacturers instructions or customer service, for removing any knobs, base, cover or screw(s) on the back of the screen to prepare mounting. These need to be removed to allow the tilt brackets to be attached. Select the small, medium, large or extra large screws from the baffl ed fastener pack then attach tilt brackets to screen following fi gure 2.1 or 2.2.

Peerless Industries PT660 — Attaching Tilt Brackets to Screen using Baffl ed Fastener Pack diagram (page 6)
Fig. 5 · Attaching Tilt Brackets to Screen using Baffl ed Fast…

HANDLES FACE OUT

BB

Peerless Industries PT660 — HANDLES FACE OUT diagram (page 6)
Fig. 6
  • The number of fasteners used will vary, depending upon the type of screen.
  • Multi-washers and spacers may not be used, depending upon the type of screen.
  • Use the corresponding hole in the multi-washer that matches your screw size as shown.
Page 7 of the Peerless Industries PT660 user manual — For Bump-out or Recessed Back Screen
Page 7 · click to enlarge
Page 7

For Flat Back Screen

Begin with the shortest length screw, hand thread through multi-washer and tilt bracket into screen as shown below. Screw must make at least three full turns into the mounting hole and fi t snug into place. Do not over tighten. If screw cannot make three full turns into the screen, select a longer length screw from the baffl ed fastener pack. Repeat for remaining mounting holes, level brackets and tighten screws.

Peerless Industries PT660 — For Flat Back Screen diagram (page 7)
Fig. 7 · For Flat Back Screen

For Bump-out or Recessed Back Screen

Begin with longer length screw, hand thread through multi-washer, tilt bracket and spacer in that order into screen as shown below. Screw must make at least three full turns into the mounting hole and fi t snug into place. Do not over tighten. If screw cannot make three full turns into the screen, select a longer length screw from the baffl ed fastener pack. Repeat for remaining mounting holes, level brackets and tighten screws.

Peerless Industries PT660 — For Bump-out or Recessed Back Screen diagram (page 7)
Fig. 8 · For Bump-out or Recessed Back Screen
Page 8 of the Peerless Industries PT660 user manual — fi g 4.1
Page 8 · click to enlarge
Page 8

Mounting and Removing Flat Panel Screen

BB &

  • Always use an assistant or mechanical lifting equipment to safely lift and position the fl at panel screen.
  • Do not tighten screws with excessive force. Overtightening can cause damage to mount. Tighten screws to 40 in.
  • lb (4.5 N.M.) maximum torque.

DETAIL 1

  • Be careful not to pinch fi ngers when pushing screen from the bottom.

RATCHET

HANDLE AA

Tension Adjustment of Ratchet Handle: Adjust tension in tilt brackets (BB & CC) by rotating ratchet handle. NOTE: If obstruction prevents ratchet handle from rotating, pull handle out while turning will allow handle to reposition without tightening. Release and turn handle to tighten or loosen.

SAFETY SCREW

BB &

CROSS SECTION

fi g 3.1

Mounting Screen: Ratchet handle must be in the up or down position or interference will occur while hooking tilt brackets to wall plate (AA). Slowly hook tilt brackets (BB & CC) onto wall plate (AA) and swing screen down as shown in fi g. 3.1. Tilt bracket hooks must fully engage wall plate as shown in detail 1. Using phillips screw driver, turn safety screws on tilt brackets (BB & CC) clockwise till screw tip securely contacts wall plate as shown in cross section.

Screen Adjustment: Screen can be adjusted horizontally by loosening safety screws on tilt brackets (BB & CC) three full turns with phillips screw driver. Adjust screen as shown in fi g. 3.2. Tighten safety screws on tilt brackets till screw tip securely contacts wall plate as shown in cross section.

fi g 3.2

Removing Screen: To remove screen from mount, loosen safety screws, swing screen away from mount, and lift screen off of mount.

Adjusting the Tilt Angle of the Flat Panel Screen

IncreLok™ TILT LOCKING SCREW

LOCATOR

HOLE

For preset tilt angles use Increlok™ and for custom tilt angle use ratchet handle.

INCRELOK™: The screen can be locked into a pre-set tilt position of -5°, 0°, 5°, 10° or 15°. Use locator hole to fi nd tilt position hole and tilt screen to align holes. Tighten IncreLok™ tilt locking screws on both tilt brackets to lock tilt as shown in detail 2.

RATCHET

HANDLE TILT POSITION

HOLES

DETAIL 2

Ratchet Handle: Loosen ratchet handle (refer to step 3 for tension adjustment of handle). Push or pull from top or bottom of screen to adjust tilt as shown in fi g. 4.1. The tilt can be adjusted to a maximum of 15° forward or 5° backward.

fi g 4.1

© 2009, Peerless Industries, Inc. All rights reserved. All other brand and product names are trademarks or registered trademarks of their respective owners.

Peerless Industries, Inc.

3215 W. North Ave. Melrose Park, IL 60160 www.peerlessmounts.com

Ask about the Peerless Industries PT660

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Peerless Industries PT660

Be the first to ask — other owners or our team will answer.

Original document

Peerless Industries PT660 manual PDF

34 pages·3.7 MB·TV Mount·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…