Page 1 of the Peerless Industries PFT640 user manual — Installation and Assembly:
Page 1 · click to enlarge
Page 1
Peerless Industries PFT640 — Installation and Assembly: diagram (page 1)
Fig. 1 · Installation and Assembly:

Installation and Assembly:

Paramount™ Flat and Tilt Wall Mount for LCD and Plasma Flat Panel Screens

Peerless Industries PFT640 — Installation and Assembly: diagram (page 1)
Fig. 2 · Installation and Assembly:

Product is UL rated for screen size range and load capacity per chart below

Model#Screen size rangeMax UL Load Capacity PFT64023" - 46"100 lb (45 kg) PFT66037" - 60"175 lb (79 kg)
  • Features:
  • Built-in flat and fixed-tilt feature
  • Incremental tilt of 0°, 2°, 5° and 10°

Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.

  • 3215 W. North Ave.
  • Melrose Park, IL 60160
  • (800) 865-2112 or (708) 865-8870
  • Fax: (708) 865-2941
  • <a href="http://www.peerlessmounts.com" rel="nofollow noopener" target="_blank">www.peerlessmounts.com</a>
Page 3 of the Peerless Industries PFT640 user manual — B C
Page 3 · click to enlarge
Page 3

Before you begin, make sure all parts shown are included with your product.

Parts may appear slightly different than illustrated.

Peerless Industries PFT640 — B C diagram (page 3)
Fig. 3

PFT640 PFT660 Description Qty. Part # Part # A wall plate 1 201-P1300 201-P1311 B vertical bracket 2 201-0370 201-0371 C #14 x 2.5" wood screw 4 5S1-015-C03 6 5S1-015-C03 D alligator® anchor 4 590-0097 6 590-0097

B C

D

Adapter Bracket Fasteners

M5 x 12 mm

M6 x 12 mm

M4 x 12 mm

M6 x 20 mm

M4 x 25 mm

M5 x 25 mm

M6 x 25 mm

M6 x 30 mm

I.D. 5.6 mm

I.D. 6.5 mm

M8 x 16 mm

M8 x 25 mm

M8 x 40 mm

I.D. 5.1 mm

I.D. 8.7 mm

Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.

Show 17 more labels / short text on this page
520-1027 · 520-1128 · 504-9013 · 520-9402 · 504-1015 · 520-9543 · 520-1208 · 510-9109 · 540-1057 · 540-1058 · 520-9257 · 520-1031 · multi-washer · 580-1036 · 520-1136 · 540-1040 · 540-1059
Page 4 of the Peerless Industries PFT640 user manual — fig. 1.1 C
Page 4 · click to enlarge
Page 4

Installation to Double Wood Stud Wall

  • Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
  • Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is highly recommended.
  • Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations.

Wall plate (A) can be mounted to two studs that are 16" apart. Use a stud finder to locate the edges of the studs. Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical line down each stud’s center. Place wall plate on wall as a template. The top mounting slots should be located above the desired screen center as shown in figure 1.1. Note: Screen tilt will determine wall plate location. Level plate, and mark the center of the two mounting holes. Make sure that the mounting holes are on the stud centerlines. Drill two 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Make sure that the wall plate is level, secure it using two #14 x 2.5" wood screws (C) as shown in figure 1.2.

Skip to step 2 on page 7.

Peerless Industries PFT640 — Installation to Double Wood Stud Wall diagram (page 4)
Fig. 4 · Installation to Double Wood Stud Wall
Peerless Industries PFT640 — Installation to Double Wood Stud Wall diagram (page 4)
Fig. 5 · Installation to Double Wood Stud Wall
TiltX Distance 0°5.8" (147 mm) 2°2.8" (71 mm) 5°5.8" (147 mm) 10°2.8" (71 mm)

fig. 1.1 C

Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.

Page 5 of the Peerless Industries PFT640 user manual — Installation to Triple Wood Stud Wall
Page 5 · click to enlarge
Page 5

Installation to Triple Wood Stud Wall

  • Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.
  • Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is highly recommended.
  • Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers are responsible to provide hardware for other types of mounting situations.

1 Wall plate (A) can be mounted to three studs that are 16" apart. Use a stud finder to locate the edges of the studs. Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical line down each stud’s center. Place wall plate on wall as a template. The top mounting slots should be located above the desired screen center as shown in figure 1.3. Note: Screen tilt will determine wall plate location. Level plate, and mark the center of the six mounting holes. Make sure that the mounting holes are on the stud centerlines. Drill six 5/32" (4 mm) dia. holes 2-1/2" (65 mm) deep. Make sure that the wall plate is level, secure it using six #14 x 2.5" wood screws (C) as shown in figure 1.4.

Skip to step 2 on page 7.

Peerless Industries PFT640 — Installation to Triple Wood Stud Wall diagram (page 5)
Fig. 6 · Installation to Triple Wood Stud Wall
TiltX Distance 0°9" (229 mm) 2°6" (152 mm) 5°9" (229 mm) 10°6" (152 mm)

Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.

Page 6 of the Peerless Industries PFT640 user manual — INCORRECT CORRECT
Page 6 · click to enlarge
Page 6

Installation to Solid Concrete or Cinder Block

  • When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
  • Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
  • Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

Make sure that wall plate (A) is level, use it as a template to mark two mounting holes. The top mounting hole should be above the desired screen center as shown in figure 1.1 on page 4 or figure 1.3 on page 5. NOTE: Screen tilt will determine wall plate location. Drill two 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (D) in holes flush with wall as shown (right). Place wall plate over anchors and secure with #14 x 2.5" screws (C). Level, then tighten all fasteners.

solid concrete cinder block

D

PFT640 WALLPLATE

s o lid c D C A PFT660 WALLPLATEk c lo b r e d in c te re c n o 1 Drill holes and insert anchors (D) 2 Place plate (A) over anchors (D) 3 Tighten all fasteners.concrete surface D . A C D and secure with screws (C).
  • Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
  • Never tighten in excess of 80 in.
  • lb (9 N.M.).
  • Always attach concrete anchors directly to loadbearing concrete.
  • Never attach concrete anchors to concrete covered with plaster, drywall, or other finishing material. If mounting to concrete surfaces covered with a finishing surface is unavoidable, the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8", custom fasteners must be supplied by installer (not UL approved).

INCORRECT CORRECT

CUTAWAY VIEW

Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.

Show 5 more labels / short text on this page
concrete wall plate · wall plate · concrete · plaster/ dry wall · plaster/ dry wall
Page 7 of the Peerless Industries PFT640 user manual — Installing Vertical Brackets
Page 7 · click to enlarge
Page 7

Installing Vertical Brackets

Peerless Industries PFT640 — Installing Vertical Brackets diagram (page 7)
Fig. 7 · Installing Vertical Brackets
  • Tighten screws so adapter brackets are firmly attached. Do not tighten with excessive force. Overtightening can cause stress damage to screws, greatly reducing their holding power and possibly causing screw heads to become detached. Tighten to 40 in.
  • lb (4.5 N.M.) maximum torque.
  • If screws don't get three complete turns in the screen inserts or if screws bottom out and bracket is still not tightly secured, damage may occur to screen or product may fail.

To prevent scratching the screen, set a cloth on a flat, level surface that will support the weight of the screen. Place screen face side down. If screen has knobs on the back, remove them to allow the adapter brackets to be attached. Place vertical brackets (B) on back of screen. Align to holes, and center on back of screen as shown in figure 2.1. Attach the vertical brackets to the back of the screen using the appropriate combination of screws, multi-washers, and spacers as shown in figure 2.3. NOTE: Be sure to attach vertical brackets with wall support brackets positioned at the bottom of screen as shown in figure 2.1.

Verify that all holes are properly aligned, and then tighten screws using a phillips screwdriver.

Peerless Industries PFT640 — Installing Vertical Brackets diagram (page 7)
Fig. 8 · Installing Vertical Brackets
Peerless Industries PFT640 — Installing Vertical Brackets diagram (page 7)
Fig. 9 · Installing Vertical Brackets
  • Always use multi-washers when attaching vertical brackets ( B ) to your screen.
  • Use the corresponding hole in the multiwasher that matches your screw size as shown in figure 2.2.
  • Spacers may not be used, depending upon the type of screen.

Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.

Page 8 of the Peerless Industries PFT640 user manual — For Flat Back Screen
Page 8 · click to enlarge
Page 8

For Flat Back Screen

If you have any questions, please call Peerless customer care at 1-800-865-2112 or visit our website at www.peerlessmounts.com/1 for PFT640 models or www.peerlessmounts.com/6 for PFT660 models, to locate your screen compatibility chart.

Begin with the shortest length screw, hand thread through multi-washer and adapter bracket into screen as shown below. Screw must make at least three full turns into the mounting hole and fit snug into place. Do not over tighten. If screw cannot make three full turns into the screen, select a longer length screw from the baffled fastener pack. Repeat for remaining mounting holes, level brackets and tighten screws.

fig. 2.3 SCREEN MULTI-WASHER SCREW ADAPTER BRACKET (B) If you have any questions, please call Peerless customer care at 1-800-865- If you ha ve any questions,pl r Recessed Back Sc ny questions, please call P ssmounts.com/1 for PFT compatibility chart. nger length screw, hand th own below. Screw must mreen eerless customer care at 1-800-865-2112 or visit 640 models or www.peerlessmounts.com/6 for read through multi-washer, adapter bracket and s ake at least three full turns into the mounting hol
havfig. 2.4 SCREEN MULTI-WASHER SPACER SCREW ADAPTER BRACKET (B) e any questions, please call Peerless customer care at 1-800-865- e anyquestions, pleas
Peerless Industries PFT640 — For Flat Back Screen diagram (page 8)
Fig. 10 · For Flat Back Screen

Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.

Page 9 of the Peerless Industries PFT640 user manual — REMOVE WALL SUPPORT BRACKETS AND SCREWS
Page 9 · click to enlarge
Page 9
Peerless Industries PFT640 — Mounting Flat Panel Screen diagram (page 9)
Fig. 11 · Mounting Flat Panel Screen
Peerless Industries PFT640 — Mounting Flat Panel Screen diagram (page 9)
Fig. 12 · Mounting Flat Panel Screen
  • Always use an assistant or mechanical lifting equipment to safely lift and position the plasma television.
  • Be careful not to pinch fingers when pushing screen from the bottom.

Mounting Flat Panel Screen

To Mount Screen With No Tilt or 2° Tilt

Hook vertical brackets (B) onto wall plate (A) using top hooks for no tilt and bottom hooks for 2° tilt as shown in figure 3.3. Hooks of vertical brackets must be engaged securely onto wall plate as shown in detail 1, then slowly swing screen toward wall as shown in figure 3.1. Screen can be adjusted horizontally if desired as shown in figure 3.4.

Peerless Industries PFT640 — To Mount Screen With No Tilt or 2° Tilt diagram (page 9)
Fig. 13 · To Mount Screen With No Tilt or 2° Tilt

REMOVE WALL SUPPORT BRACKETS AND SCREWS

FOR 5° OR 10° TILT

To Mount Screen With 5° or 10° Tilt

Remove wall support brackets and screws from vertical brackets as shown in figure 3.2. Hook vertical brackets (B) onto wall plate (A) using top hooks for 5° tilt and bottom hooks for 10° tilt as shown in figure 3.3. Hooks of vertical brackets must be engaged securely onto wall plate as shown in detail 1, then slowly swing screen toward wall as shown in figure 3.1.

Peerless Industries PFT640 — REMOVE WALL SUPPORT BRACKETS AND SCREWS diagram (page 9)
Fig. 14

Screen can be adjusted horizontally if desired as shown in figure 3.4.

To remove screen from mount, slowly swing bottom of screen away from wall and slightly push top of screen toward wall to disengage hooks on vertical brackets (B) from wall plate (A). Lift screen off of wall plate as shown in figure 4.1.

Visit the Peerless Web Site at www.peerlessmounts.com For customer care call 1-800-865-2112 or 708-865-8870.

© 2008, Peerless Industries, Inc. All rights reserved. All other brand and product names are trademarks or registered trademarks of their respective owners.

Ask about the Peerless Industries PFT640

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Peerless Industries PFT640

Be the first to ask — other owners or our team will answer.

Original document

Peerless Industries PFT640 manual PDF

27 pages·563 KB·TV Mount·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…