Instruction/ maintenance manual of the product Monarch 9876 Paxar
Go to page of 38
Operating & Maintenance Instr uctions Operating & Maintenance Instr uctions Monar ch 9876™ Mobile W ork Station (MWS™) ™ TC9876OI Rev . AJ 12/07 ©2007 Paxar Americas, Inc.
Each product and program carries a respective written warranty , the only warranty on which the customer can rely . Paxar reserves the right to make changes in the product, the programs, and their availability at any time and without notice.
T ABLE OF CONTENTS GETTING ST ARTED ................................................... 1-1 Using this Manual ............................................... 1-1 Safety Precautions ....................................... 1-1 Audience .................
POWER OPTIONS ..................................................... 4-1 Standard or Symbol 24VDC ....................................... 4-1 24VDC/115V AC Power Inverter .................................... 4-3 AC/DC Output (Power Inverter) ..........
GETTING ST ARTED 1 Use the Monarch ® 9876 ™ Mobile W ork Station ™ (MWS ™ ) for mobile printing. Using This Manual Following is a summary of the contents of this manual. Chapter Contents 1 Getting Started Contains information about the batteries and MWS.
Audience This manual is designed for the person using the MWS for mobile printing applications. After you receive the MWS, you should have all the necessary parts, including the batteries and charger . Check inside ALL packaging material . Make sure you do not throw away any pieces.
ABOUT THE MWS 2 The Mobile W ork Station ships mostly assembled. This chapter explains the different options and how to assemble any special options, such as the hanging folders.
Handle Options There are different handle configurations and each option is pictured below . Y ou can have one or two curv ed handles. 2 - 2 About the MWS One Curved Handle T wo Curved Handles.
Shelf Options Y ou can have one or two shelv es. T o collapse the shelf, lif t the shelf from the sides and allow it to swing down. T o extend the shelf, lift the shelf until the rear lip slides down onto the top of the support brace and locks in place.
About the Doors The MWS has combinations of doors and solid panels that do not open. The doors should already be attached to the MWS. Use water or a glass and surface cleaner to clean the doors/panel. Do not use solvents on these doors/panel. A solvent will damage the door/panel.
Attaching the Hanging Folders Follow the steps below to att ach the hanging folders to the MWS. Doors must be installed before you can use the hanging folder option. Y ou must attach the bottom folder to the MWS first. 1. Remove the following items from their p ackaging: (2) hanging folders (4) Philips screws 2.
Connecting the Power Cord Make sure to set the proper voltage on the charger voltage selector switch on the right side of the charger (115V in U.S. or 230V International). Incorrect voltage selection can result in charger failu re. Connect the charger's power cord to the power inlet.
Connecting a Printer Contact your Monarch Representative for instructions on attaching a Monarch® printer to the MWS. Using other Monarch® Printers Contact your Monarch Representative for instructions on connecting Monarch® 9462 ™ and Monarch® 9465 ™ chargers to the MWS.
2-8 About the MWS.
CHARGING THE BA TTERIES 3 This chapter describes how to u charge the Mobile W ork Station’s batteries u change the fuses. The battery charger is a fully automatic, maintenance-free charger . Make sure the voltage selector switch (located on the back o f the charger) is set for the proper voltage (115V o r 220V).
Important Charging Information WARNING DANGER! RISK OF ELECTRICAL AND FIRE HAZARD. CERT AIN ACTIONS MA Y RESUL T IN DEA TH, SERIOUS INJURY , SHOCK, OR BURNS. u Do not disassemble the battery charger . u Do not operate the charger if it has been damaged in any way .
About the Battery Charger u Store the charger in a dry area not subject to prolonged sub-zero temperatures. u The battery charger is “intelligent;” it monitors the batteries condition and does not overcharge the batteries. It is recommended to leave the battery charger plugged in and charging when the Station is not in use.
Battery Life If you leave the battery charger plugged in and constantly charging when the MWS is not in use , the battery life is maximized for the application. The charger will not overcharge the batteries. The MWS has signal lights to indicate the battery status as follows.
F requency of Charging/R un- Time Guidelines The following information is approximate and should be used for reference. Many factors effect an individual battery’ s performance: u the presence of au.
Changing F uses There are two fuses for the MWS: one connecting the batteries and one from BA T2 to the terminal block. Depending on the power option selected when you ordered the MWS, the size of the fuses varies. See Chapter 4, “Power Options,” for more information.
POWER OPTIONS 4 Y our MWS was ordered with one of these power options: u Standard 24VDC u Symbol 24VDC u 24VDC/115V AC (uses the power inverter for AC power . The power inverter is only 115V .) u AC/DC Output with the power inverter . The power inverter is only 115V .
Check the wiring for your batteries and charger . Make sure the ground wire is att ached using one M5 screw with two M4 nut s and M4 washers as shown. Keep the Mobile Work S tation’ s power switch ON when continuously operating the MWS and/or printer(s).
24VDC/115V AC Power Inverter The AC power inverter is only 1 15V . The AC power inverter uses battery power , so the batteries may require more frequent charging. WARNING Remove ALL fuses from the cables before connecting ANY cables to the batteries or switch.
Make sure the ground wires are att ached using one M5 screw with two M4 nuts and M4 washers as shown. WARNING This equipment contains components which can produce arcs or sparks.
AC/DC Output (Power Inv erter) Uses the power inverter for AC power , along with the standard 24VDC for a Paxar/Monarch printer . The power inverter is only 1 15V . The AC power inverter uses battery power , which may require more frequent charging of the batteries.
Check the connections between the inverter ’s cables, the batteries and the inverter ’s switch as follows: heavy-gauge red cable assembly to positive (+) on BA T2 heavy-gauge black cable to negati.
WARNING Y ou may observe a spark when you make this connection since current flows to charge capacitors in the power inverter . Do not make this connection in the presence of Flammable fumes. Explosion or fire may result. Operation of the inverter without a proper ground connection may result in an electrical safety hazard.
Using the Remote Switch The Mobile Work S tation’ s On/Off switch should be used as a remote switch to turn the inverter ON or OFF . T o do this: 1. On the inverter ’s front p anel, set the ON/OFF/REMO switch to OFF or REMO. 2. Make sure the switch on the electrical panel is OFF .
T o conserve the battery , make sure the Mobile W ork S tation’s power switch is turned OFF when not in use OR when charging the batteries. For optimal (shortest) charging time, turn of f the MWS and printer while charging. u If you need to finish a batch, you can print while charging, as long as the batteries are not too depleted.
4- 10 P ower Options.
SPECIFICA TIONS A Utility Cart Height Approximately 42 inches (1067 mm) depending on selected options Width 23 inches (584 mm) Length 28 inches (711 mm) W eight Approximately 150 lbs (68 kg) depending.
Charger Input 117V AC 60Hz, 320V A (V olt Amps) Output 24 V olts, 8 Amps DC u Electronic reverse polarity and short circuit-shutdown u Low voltage start (total battery voltage must be greater than 1V to charge) u AC input fuse in AC input connector Use only NRTL -listed accessories (National Recognized T esting Lab).
WIRING DIAGRAMS B This appendix contains wiring diagrams for the various power options: u Standard 24VDC u Symbol 24VDC u WM 24VDC (DC/DC Converter) u 24VDC/115V AC P ower Inverter WARNING Only qualified service personnel may install or replace the two 12-volt sealed lead acid batteries used to power the printer on the Station.
Standard 24VDC B - 2 Wiring Diagrams G L N 124589 126523 126523 126491 or 126803.
Symbol 24VDC Wiring Diagrams B-3 G L N 126471 126763 126762 126679 126678 126769 126768 126769 126490 126490 126679 126679 126473 126761 126575 126624 126759 126523 126523 126491 or 126803.
WM 24VDC (DC/DC Converter) B - 4 Wiring Diagrams BATTERY JUMPER CONNECT 30 AMP FUSED (F2) P ART# 124845 SWITCH #124828 P ART# 124930 PRINTER & RELAY PWR HARNESS "PRT PWR" BATTERY STA TUS.
24VDC/115VAC P ower Inverter Wiring Diagrams B-5 126767 126766 126765 126764 126764 126764 126764 126763 126678 126490 126473 125584 126759 126679 126679 126761 126681 126762 126575 126624 126523 1265.
Visit www .paxar .com for sales, service, supplies, information, and telephone numbers for our locations throughout the world. TOLL FREE: 1-800-543-6650 (In the U.
An important point after buying a device Paxar Monarch 9876 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Paxar Monarch 9876 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Paxar Monarch 9876 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Paxar Monarch 9876 you will learn all the available features of the product, as well as information on its operation. The information that you get Paxar Monarch 9876 will certainly help you make a decision on the purchase.
If you already are a holder of Paxar Monarch 9876, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Paxar Monarch 9876.
However, one of the most important roles played by the user manual is to help in solving problems with Paxar Monarch 9876. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Paxar Monarch 9876 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center