User Manual

For Quick · Start Installation

Patton Electronics Company, Inc.
7622 Rickenbacker Drive Gaithersburg, MD 20879 USA
Trademark Statement The term ForeSight is a trademark of Patton Electronics Company. All other trade- marks presented in this document are the property of their respective owners.
Copyright © 2012, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Elec- tronics assumes no liability for errors that may appear in this document.
Warranty Information The software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license. For information about the license, go to www.patton.com.
Patton Electronics warrants all NMS components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If the product fails to perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warran- ties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

1 Introduction 15
2 Discovering Your Network 24
3 Configuring Alarms and Clocking 46
4 Configuring and Managing Devices 57
5 Configuring the 2616RC Card 67
6 Configuring the 3096RC Card 83
7 Configuring the 3196RC Card 105
8 Configuring the 6511RC Card 126
9 Configuring Chassis 139
10 Contacting Patton for assistance 143


1 Logging in to the application client 17 2 FS6300 Schedule Tasks window 22 3 Add Backup Policy 22 4 Policy Details 23 5 Policy Scheduler 23 6 Tools > Discovery Administration 25 7 SetUp(F) > 6300 Container Definition 25 8 Add Container 26 9 Modify Container 27 10 View Containers 28 11 Tools > Multiple Card Configuration 29 12 Multiple Card Configuration > Card Parameters 29 13 Container IDs in the NMS 30 14 Set Initial Parameters 31 15 Discovery Window 32 16 Network Discovery tab 33 17 Set Discovery Interval 34 18 Configure Discovery for SNMP Devices 35 19 SetUp > Add Device 36 20 Add SNMP Device 36 21 Stop Discovery in progress 37 22 Re-Discover Already Discovered 38 23 Re-Discover Cards 38 24 Schedule Re-Discovery for Regular Intervals 39 25 Schedule Re-Discovery for Specific Dates 40 26 Schedule Re-Discovery for Days of the Week 41 27 Tools > Multiple Card Configuration 42 28 Multiple Card Configuration > Card Parameters 42 29 Multiple Card Configuration > Record Current Configuration 43 30 Tools > Firmware Upgrade 44 31 Firmware Upgrade window 45 32 Alarm Trap Manager 47 33 View Alarm Details 48 34 Modify Alarm Details 49 35 Alarm Summary View options (Tabular, Graphical, and Pie Chart) 50 36 Example: Custom Alarm View for Critical Alarms 51 37 Example: Custom Alarm View for Specific Card 51 38 Alarm Custom Views 52 39 Chassis Menu > Chassis Clocking Sync 53 40 Modify System Clocking 53 41 Card Menu > Card System Clocking 54 42 View System Clocking 55 43 Modify System Clocking 55 44 Add SNMP Device window 58 45 Network Maps 59 46 Container IDs in the NMS 59 47 Record Current Configuration 60

FS6300 NMS User Manual
48 Hard Reset 60 49 Set Factory Default Configuration 61 50 Card Events and Alerts 62 51 FS6300 Export Card Configuration window 63 52 Export Complete 63 53 Import Card Configuration 64 54 Successful Import 64 55 Modify System Log 65 56 Set System Card Alarm Status 65 57 2616RC Configuration Menu 68 58 2616RC Front Panel LEDs 69 59 Modify 2616RC Card System Parameters 70 60 Modify 2616RC Ethernet Parameters 71 61 2616RC IP Overview 72 62 Add a New Route for 2616RC 73 63 Modifying a Route for 2616RC 73 64 PPP Link Configuration 74 65 PPP Default Packet Settings 76 66 T1/E1 Link Configuration window 78 67 T1/E1 Test Settings 80 68 T1/E1 Channel Assignment 81 69 2616RC T1/E1 Reports 82 70 2616RC T1/E1 Port Map 82 71 3096RC Configuration Menu 84 72 3096RC Front Panel LEDs 85 73 Modify Card System Parameters 86 74 Modify Ethernet Parameters 87 75 3096RC G.SHDSL window 88 76 3096RC Edit G.SHDSL Configuration 89 77 3096RC Edit CO Options 90 78 3096RC Line Provision Tool 91 79 3096RC G.SHDSL Reports 92 80 3096RC IP Overview 93 81 Add a New Route for 3096RC 94 82 Modifying a Route for 3096RC 94 83 PPP Link Configuration 95 84 PPP Default Packet Settings 97 85 T1/E1 Link Configuration window 99 86 T1/E1 Test Settings 101 87 T1/E1 Channel Assignment 102 88 3096RC T1/E1 Reports 103 89 3096RC T1/E1 Port Map 103 90 3096RC G.SHDSL Port Map 104 91 3196RC Configuration Menu 106 92 3196RC Front Panel LEDs 107 93 Modify Card System Parameters 108 94 Modify Ethernet Parameters 109 95 3196RC iDSL window 110 96 3196RC Edit iDSL Configuration 111 97 3196RC Modify iDSL Alarm Thresholds 113 98 3196RC iDSL Reports 113


1 Troubleshooting messages 19 2 FS6300 NMS Backup Policy Properties 23

The Patton ForeSight 6300 NMS User Manual helps you configure basic operations for the FS6300 Network Management System (NMS). For more detailed information about configuring advanced features, see the ForeSight 6300 NMS Administrator’s Reference Guide.
This guide is intended for the following users:
This guide contains the following chapters and appendices:
For best results, read the contents of this guide before you install the NMS.


FS6300 NMS User Manual 1 • Introduction
This chapter introduces you to the features and benefits of the FS6300 NMS. It also includes basic information about logging in and out of the system, and working with the main toolbars and menus.
The following are user tasks you will encounter when working with the FS6300 NMS:
Overview 16

FS6300 NMS User Manual 1 • Introduction
To start the server, from the /opt/FS6300/Server/<release #> directory, double-click on the WebNM- SLauncher.sh file to open the launcher. To start and stop the server, in the splash screen window, right-click on the Start 6300 NMS Server icon and select Run. To initialize the database, right-click on the Reintialize 6300 NMS icon and select Run, then acknowledge the confirmation request in the pop-up window.
The NMS Windows Remote Application Client (WRAC) is the primary client for the FS6300 NMS. It is rec- ommended that you use the WRAC. You can launch the WRAC by double-clicking on the WebNM- SLauncher.bat icon on the desktop. In the resulting splash screen window, right-click on the client icon and select Run. Then, enter the authentication information in the FS6300 NMS Authentication dialog box.
The FS6300 NMS Authentication box is displayed to provide an authenticated access to the FS6300 NMS. Enter a valid user name and password to access the Application Client.

Figure 1. Logging in to the application client
The splash screen with a progress bar is shown before the Application Client is completely opened.
Bringing up the NMS Server from Linux 17

FS6300 NMS User Manual 1 • Introduction
Configuring your password before connecting to the client When you log on to the Application Client for the first time, a Password Confirmation dialog box is displayed (only if this has been enabled by your administrator). If you do not see this dialog box, then ignore this section and perform the steps explained in the next section, “Configuring your password from the client” on page 18 .
To configure your password before connecting to the client:
The new password is assigned to you and you are connected to the Application Client. You need to use this new password from the subsequent login.
Configuring your password from the client 1. After logging into the client, select Security Administration from the Tools menu. Select the user from the users list, and click Edit in the Menu bar. Select Change Password. The Password Configurator window is displayed.
Logging into the Application Client 18
Configuring Your Password

FS6300 NMS User Manual 1 • Introduction
Troubleshooting Table 1 lists the messages that are displayed in certain situations during the login process.
Table 1. Troubleshooting messages
Message Why am I getting this? What do I do?
You are logged in for the first time; would you like to reuse the existing password or configure a new pass- word? (See “Configuring your pass- word before connecting to the client” on page 18).
This pop-up message is displayed when you log on to the Application Client for the first time (only if this has been enabled by your administrator).
Refer to “Configuring your password before connecting to the client” on page 18 for the procedure.
Your password has expired. Would you like to reuse the old password or configure a New password?
Your password has expired. • You can either set a new password or retain the old password.
This User account has Expired. Please contact the Administrator for further details
Your user account has expired. The user account is created by your sys- tem administrator.
Contact your system administrator to renew your user account.
This User account is Disabled. Please contact the Administrator for further details
Contact your system administrator to enable your user account.
Logging into the Application Client 19

FS6300 NMS User Manual 1 • Introduction
Table 1. Troubleshooting messages
Message Why am I getting this? What do I do?
Connection lost to the FS6300 NMS server at <host>. Do you want to shut- down the client?
This message is displayed if the con- nection between the client and server is lost due to network problems or if the server is shut down abruptly.
[Lock Screen dialog box] Please enter your password to unlock the client
This dialog box is displayed when the Application Client is idle for more than a specific period, that is, when there is no interaction between the user and the Application Client (no mouse or keyboard events).
FS6300 NMS Application Client has been terminated
Bring up/reopen the client again.
Logging into the Application Client 20

FS6300 NMS User Manual 1 • Introduction
The following menu items are always available at the top of the main window of the NMS:
Additionally, some options in the menu tree have other toolbars at the top related to their function in the net- work:
Also, right-clicking on a device in the main window will display a menu of options available for that specific device.
To log out, perform any of the following procedures:
A Confirmation Message dialog box is displayed. Click Yes to quit the client.
Using the NMS Menus 21

FS6300 NMS User Manual 1 • Introduction
The FS6300 NMS provides a tool for backing up the database. You may also create a policy to backup the database automatically based on a schedule.
Creating a backup file of the database 1. Click Tools > Schedule Tasks in the main window. In the FS6300-Schedule Tasks window, select the radio button for Database Backup.

Figure 2. FS6300 Schedule Tasks window
Scheduling a policy to backup the database The 6300 NMS Backup policy automatically backups the system to reduce the load on the server.

Figure 3. Add Backup Policy
Backing Up the Database 22

FS6300 NMS User Manual 1 • Introduction

Figure 4. Policy Details
Table 2. FS6300 NMS Backup Policy Properties
groupname Specify the name of the group to which the policy belongs. If default is specified, the policy does not belong to any group. (You can execute different policies at the same time by associating them with a common group name).
name Displays the name of the backup policy. This field cannot be edited.
BackUpClassNames Specify the class name implementing the backup interface.
Status Specify whether the status of the policy is Enabled or Disabled. The policy can be executed only when it is Enabled.

Figure 5. Policy Scheduler
Backing Up the Database 23
Property Description


FS6300 NMS User Manual 2 • Discovering Your Network
The Discovery process is the most important step in working with the NMS. This chapter describes how to add containers before discovering your network, how to schedule rediscovery processes, and how to add a device manually to the system.
To open the Discovery window, click on Tools > Discovery Administration at the top of the screen.

Figure 6. Tools > Discovery Administration
Containers are unique identification details about the Geographical Areas, Network Nodes, and Chassis in your network. You may pre-define and create a master list of containers before initial discovery of your net- work, or you may define containers while configuring multiple cards.
Pre-Defining Containers Before Initial Discovery Before starting discovery, you may create a master list of pre-defined details for the Geographical Areas, Nodes, and Chassis in your network. When you configure multiple cards later, you can refer to your master list of con- tainers. To reach the Container Definition window, click on SetUp(F) > 6300 Container Definition at the top of the screen.

Figure 7. SetUp(F) > 6300 Container Definition
Overview 25

FS6300 NMS User Manual 2 • Discovering Your Network
Adding Pre-Defined Containers To add containers in the NMS:

Figure 8. Add Container
is added to the system. However, the Name may be modified at any time.
– Node Name (NN): Add nodes in the network to a Geographical Area. You may also add details such as
system manager and system location.
– Chassis Label: The Chassis ID must be numerical, but the Label Name is optional.
Defining Containers 26

FS6300 NMS User Manual 2 • Discovering Your Network
Modifying Pre-Defined Containers To modify pre-defined containers:

Figure 9. Modify Container
Defining Containers 27

FS6300 NMS User Manual 2 • Discovering Your Network
Viewing and Deleting Containers To view or delete containers:

Figure 10. View Containers
Defining Containers 28

FS6300 NMS User Manual 2 • Discovering Your Network
Defining Containers During Multiple Card Configuration You may wish to define containers after all of the chassis in your network have been discovered. In this case, you may add IDs, details, and labels during the multiple card configuration process. To reach the Multiple Card Configuration. window, click on Tools > Multiple Card Configuration. at the top of the screen.

Figure 11. Tools > Multiple Card Configuration

Figure 12. Multiple Card Configuration > Card Parameters
– Geographical Area ID (This is permanent and cannot be modified).
Defining Containers 29

FS6300 NMS User Manual 2 • Discovering Your Network
– Geographical Area Name (Descriptive name of the geographical area)
– Node ID (This is permanent and cannot be modified).
– Node Name (Descriptive name of the node)
– Chassis ID (This is permanent and cannot be modified).
– Chassis Label (Descriptive label for the chassis)
– System Manager (Name of the person managing this subnet on the network)
– System Location (Description of where the system is located)
– Chassis Type (Choose a chassis type from the drop-down menu)
If the same CH ID exists on cards in a different chassis unit but with the same subnet address, an alert is dis- played asking if the cards need to be merged into one unit.
If the same CH ID exists on cards in a different chassis unit and with different subnet address, an alert is dis- played that Chassis ID already exists.
This is to ensure uniqueness of Chassis IDs in the NMS.
The following details are also checked when modifying containers during multiple card configuration:
The NMS also verifies containers to prevent duplication of ID and name for the Network Node.
figure 13 shows a visual representation of container IDs in the NMS.
subnet of GA1-NN1-<CH2> or GA1-NN1-CH2
NN 1 NN 2 CHASSIS 1 NN 3 CHASSIS 1
(Can be represented as)
NMS
CHASSIS 1 CHASSIS 2
NN 1 NN 5 CHASSIS 1 CHASSIS 2 CHASSIS 3 CHASSIS 4
Figure 13. Container IDs in the NMS
Defining Containers 30

FS6300 NMS User Manual 2 • Discovering Your Network
The Initial Discovery process is the first discovery process that is started as soon as the FS6300 NMS server loads.
To set initial discovery parameters:

Figure 14. Set Initial Parameters
– Discovery Interval: Interval (in seconds) between the discovery of any two devices in the network.
– Rediscovery Interval: Interval (in hours) between two complete discoveries of a network.
– SNMP Timeout: Threshold value, in seconds, for all the SNMP requests.
– SNMP Retries: Number of SNMP retries for discovery, status polling, and data collection.
Configuring Initial Discovery Parameters 31

FS6300 NMS User Manual 2 • Discovering Your Network
Before starting the Discovery process, at least one node must be deployed, powered up, and connected to the network.
Enabling AutoDiscovery To start Discovery:

Figure 15. Discovery Window
Starting the Discovery Process 32

FS6300 NMS User Manual 2 • Discovering Your Network
Configuring Discovery of Specific Networks 4. Click on the Network Discovery tab at the top of the Discovery Administration window.

Figure 16. Network Discovery tab
It is very important that you do not attempt to configure any parameter during the Discovery process. Attempting to do so could corrupt the data being collected during Discovery.
When the NMS has collected enough information to identify the node, the node will be listed in the Nodes table (under Network Database). As more information is collected through the Discovery process, entries will appear in the FS6300 Geographical Areas section (under Network Maps).
Starting the Discovery Process 33

FS6300 NMS User Manual 2 • Discovering Your Network
When the Discovery process is complete, the spinning wheel icon is replaced with a blue box containing a white checkmark. Once Discovery is complete, a new subnet can be entered into the Network Discovery win- dow (Tools > Discovery Administration).
You can set the wait time between discovering devices by configuring the Discovery Interval.
To set the discovery interval:

Figure 17. Set Discovery Interval
Setting Discovery Interval 34

FS6300 NMS User Manual 2 • Discovering Your Network
SNMPdevices may not be discovered through the default discovery process. To enable discovery of SNMP devices:

Figure 18. Configure Discovery for SNMP Devices
Configuring Discovery of SNMP Devices 35

FS6300 NMS User Manual 2 • Discovering Your Network
To add a single device to the NMS database:

Figure 19. SetUp > Add Device

Figure 20. Add SNMP Device
Enter information for the following fields:
– Device IP Address: Enter the IP address of the device you want to add.
– SNMP Password: Enter the password to access the device.
– Process Add SNMP Device request in the background: Select this box if you want continue with other
operations in the NMS while the discovery process for the device runs in the background.
Adding a Device Manually 36

FS6300 NMS User Manual 2 • Discovering Your Network
You may want to stop a discovery cycle that is already in process to add or modify a network or set of devices.
To stop/restart a discovery in progress:

Figure 21. Stop Discovery in progress
Stopping/Restarting a Discovery Process 37

FS6300 NMS User Manual 2 • Discovering Your Network
By default, the rediscovery process discovers only devices that were not discovered previously. It does not redis- cover the already discovered devices. To rediscover already discovered devices:

Figure 22. Re-Discover Already Discovered
You should re-discover cards after changing a card’s configuration, or if you have added a new chassis or devices to the network. To manually re-discover cards:

Figure 23. Re-Discover Cards
Re-Discovering Already Discovered Devices 38

FS6300 NMS User Manual 2 • Discovering Your Network
You can configure and schedule how often the network goes through the re-discovery process. The rediscovery process can also be configured to run at a specific hour on a specified date of the month or specified day of the week.
You can set the Rediscovery Interval using one of the following options:
Regular Interval To schedule re-discovery for a regular interval (for example, every 24 hours):

Figure 24. Schedule Re-Discovery for Regular Intervals
Scheduling Rediscovery 39

FS6300 NMS User Manual 2 • Discovering Your Network
Specific Dates To set rediscovery on specific dates:

Figure 25. Schedule Re-Discovery for Specific Dates
– All Dates: Select the radio button for All. Re-Discovery will occur every day.
– Specific Dates: Select the radio button for Specific. Then, click on all of the dates in the month that you
want re-discovery to occur. For example, if you select 5 and 15, then the rediscovery will take place on the 5th and 15th of every month.
– All Hours: Select the radio button for All for re-discovery to occur every hour on the specified date(s).
– Specific Hours: Select the radio button for Specific. Then, click on all of the hours that you want re-dis-
covery to take place on the specified date(s).
Scheduling Rediscovery 40

FS6300 NMS User Manual 2 • Discovering Your Network
Days of the Week To set re-discovery on specific days:

Figure 26. Schedule Re-Discovery for Days of the Week
– All Days: Select the radio button for All. Re-Discovery will occur every day.
– Specific Days: Select the radio button for Specific. Then, click on all of the days of the week that you
want re-discovery to occur. For example, if you select MON TUES WED, the re-discovery occurs only on those days, every week.
– All Hours: Select the radio button for All for re-discovery to occur every hour on the specified day(s).
– Specific Hours: Select the radio button for Specific. Then, click on all of the hours that you want re-dis-
covery to take place on the specified day(s).
Scheduling Rediscovery 41

FS6300 NMS User Manual 2 • Discovering Your Network
If you have separate subnets that are supposed to be in the same Geographical Area but in a specifically named Node and Chassis, you will want to update the subnet information so that is displayed as it actually is located in the network.
Updating the Configuration To configure multiple cards:
Figure 27. Tools > Multiple Card Configuration

Figure 28. Multiple Card Configuration > Card Parameters
Configuring Multiple Cards 42

FS6300 NMS User Manual 2 • Discovering Your Network
– Geographical Area ID (Integer that identies the geographical area)
– Geographical Area Name (Descriptive name of the geographical area)
– Network Node ID (Integer used to identify the node on the network)
– Network Node Name (Descriptive name of the node)
– Chassis ID (Integer used to identify the chassis on the network)
– Chassis Name (Descriptive label for the chassis)
– System Manager (Name of the person managing this subnet on the network)
– System Location (Description of where the system is located)
– Chassis Type (Choose a chassis type from the drop-down menu)
Saving the Configuration To save the information to non-volatile memory:

Figure 29. Multiple Card Configuration > Record Current Configuration
Configuring Multiple Cards 43

FS6300 NMS User Manual 2 • Discovering Your Network
Forcing Discovery for Selected Cards Though the cards have the updated information saved, the NMS will not display the changes until the cards have been re-discovered. To re-discover specific cards and not the entire subnet, see “Re-Discovering Cards Manually” on page 38.
The FS6300 NMS supports the following Patton models:
Supported Rack Cards Supported CPE Devices
3096RC 3086
2616RC 1082 (C/D/I/F)
The rack cards must have the following minimum firmware version installed in order to operate properly:
Card Minimum Firmware Version Required
6511 6511RC-1.2.9.img
3196RC 3196RC-1.3.9.img
3096RC 3096RC-1.5.16.img
2616RC 2616RC-1.3.9.img
To update the firmware for a rack card:

Figure 30. Tools > Firmware Upgrade
6511 3201 · Upgrading Firmware 44

FS6300 NMS User Manual 2 • Discovering Your Network

Figure 31. Firmware Upgrade window
Note The NMS will upgrade the cards in the same order that they are listed in the table. In a daisy-chain topology, when the upstream card(s) are being upgraded, all “downstream” cards will be temporarily unavail- able and will not respond to an SNMP ping request. However, the other cards will be accessible as soon as the upgrade is completed for the upstream card.
Upgrading Firmware 45


FS6300 NMS User Manual 3 • Configuring Alarms and Clocking
Before you can receive alarm indications, you must first configure the alarms and clocking for the NMS. When you discover your network for the first time, there will be alarms because the synchronization clocking has not been fully configured yet.
In order to configure alarms, you need to configure the IP address of the NMS server which traps the alarm reports from each of the cards in the network. By default, the Alarm Trap IP address is 0.0.0.0, so no alarms are detected by the NMS.
You can configure the Alarm Trap Manager in two different ways, by right-clicking on a network node in the Geographical Areas section, or by right-clicking on a card in the Chassis section.
Configuring Alarms through the Network Node To configure the IP address for the Alarm Trap field for each card:

Figure 32. Alarm Trap Manager
Introduction 47

FS6300 NMS User Manual 3 • Configuring Alarms and Clocking
Configuring Alarms through a Card in the Chassis To configure the IP address for the Alarm Trap field for each card:

Figure 33. View Alarm Details
Alarm System Overview: The Alarm System Overview window shows the entire alarm system, including the following information for each alarm:
– Time Since Alarm
– Count– the number of times this alarm has occurred since being cleared
Configuring the Alarm Trap Manager 48
– Alarm Name · – Alarm Severity

FS6300 NMS User Manual 3 • Configuring Alarms and Clocking

Figure 34. Modify Alarm Details
Modify Parameters: Configure the FS6300 Alarm Parameters through the Modify Parameters window.
– Alarm Syslog Priority
– Board Temperature Threshold
– Current Board Temperature
– Alarm Trap Managers 1-4
Configuring the Alarm Trap Manager 49

FS6300 NMS User Manual 3 • Configuring Alarms and Clocking
Alarm Indications The following are symbols that appear on a card or node icon when the NMS receives an alarm:

Alarms are propagated up to the next level throughout the Network Maps section in the menu tree.The Chassis icon indicates an alarm alert if one or more of the cards have an alarm. On the Geographical Area level, a network node will also display alarm alerts if a card in a chassis has an alarm.
Viewing a Summary of Alarms To view a summary of all systems with an alarm, click on Failed Systems (under Network Maps) in the menu tree on the left side of the screen. The Failed Systems map shows all the cards that have alarm alerts.
The Alarm Summary View window always appears in the bottom left corner of the screen under the main menu tree. It offers a quick glance at the status of alarms that are currently occurring in the system. You can change how the Alarm Summary View is displayed by clicking on the icons in the Alarm Summary View win- dow. There are three different view options:



Figure 35. Alarm Summary View options (Tabular, Graphical, and Pie Chart)
Viewing Alarms 50

FS6300 NMS User Manual 3 • Configuring Alarms and Clocking
Managing Alarm Custom Views The NMS provides the ability to create custom views for specific alarms. Use custom views to display all alarms in a certain state or to view all alarms from one card or network.
Adding an Alarm Custom View 1. From the menu tree on the left side of the screen, select Alarms under Fault Management.


Viewing Alarms 51

FS6300 NMS User Manual 3 • Configuring Alarms and Clocking

Figure 38. Alarm Custom Views
Modifying an Alarm Custom View To modify an existing custom view:
Deleting an Alarm Custom View To remove an existing custom view:
Viewing Alarms 52

FS6300 NMS User Manual 3 • Configuring Alarms and Clocking
To configure clocking synchronization for a chassis:

Figure 39. Chassis Menu > Chassis Clocking Sync
The Chassis Clocking Synchronization window displays.

Figure 40. Modify System Clocking
Configuring Clocking Synchronization 53

FS6300 NMS User Manual 3 • Configuring Alarms and Clocking
Refreshing the alarms after configuring clocking After you have configured clocking for the chassis, you can refresh the alarms that occurred before clocking was configured. To refresh the alarms for a card:
All of the alarms that were related to clocking should be cleared. (Other alarms not related to clocking may still be present). The next step after configuring clocking synchronization is to configure clocking options for the card system, including Clock Fallback and Clock Auto Recover.
In addition to setting a clock to Master, Secondary, or Slave, you must also select the source for clocking and determine whether to enable or disable Clock Fallback and Clock Auto Recover. To configure card system clocking:

Figure 41. Card Menu > Card System Clocking
The System Clocking window displays.
Configuring Card System Clocking 54

FS6300 NMS User Manual 3 • Configuring Alarms and Clocking

Figure 42. View System Clocking

Figure 43. Modify System Clocking
Configuring Card System Clocking 55

FS6300 NMS User Manual 3 • Configuring Alarms and Clocking
Main Reference and Fallback Reference The Main Reference and Fallback Reference parameters define a primary and secondary (fallback) reference for the card system clock source (and for all blades in the chassis when the card’s clocking mode is defined as mas- ter). The card will use the fallback reference if and only if the main reference becomes unavailable.
When defining the main and fallback clocking sources, you can select a WAN port or the card’s internal clock pulse oscillator. The card will use the main reference as its system clocking source unless the main reference fails or is disconnected.
When the main reference becomes unavailable, the card will switch to the fallback reference as its system clock- ing source. Both parameters will be defined from the same set of possible values. For the fallback reference to serve its purpose, however, you must define it by selecting a value different from the main reference. You must also enable the card’s fallback mechanism (see below). For the card’s main and secondary clocking references, you can choose:
– • wan(602)—Clocking derived from the network clock received at the WAN interface.
– • internal(200)—Uses the card’s internal free-running oscillator for the clock source.
Clock Fallback Select to enable or disable the card’s fallback feature. The fallback feature, when enabled, allows the card to switch to a secondary clock as follows:
– Enable - Master or secondary mode—The card, upon failure of the primary reference clock source, will
switch to the selected fallback reference clock source.
– Disable - Slave Mode—The card defaults (fallback feature options are not accessible to user) to system
for both main reference and fallback reference—since the slave cards do not provide clock to the chassis, they receive clock from the system clocking bus provided by a master or secondary card.
Clock Auto Recover Select to enable or disable the clock auto recover feature. The Auto Recovery Feature , when enabled, will cause a card (in master or secondary mode), which is operating on fallback reference clock due to a failure of the pri- mary reference clock, to switch back to primary reference clock when it becomes available.
When disabled, the card, operating on fallback reference clock, will not switch back to primary reference clock, even if the primary reference becomes available.
Click Submit to commit your changes. You will need to record the current configuration to save your changes to the card’s volatile memory. (See “Record the current configuration” on page 60).
Configuring Card System Clocking 56


FS6300 NMS User Manual 4 • Configuring and Managing Devices
Devices can be individually configured and monitored through the FS6300 NMS. The NMS organizes devices by geographical area in the Network Maps section of the menu tree, where device-specific menus can be viewed by right-clicking on a device. Devices can also be monitored through the Network Database section of the menu tree.
This chapter describes what information you can find and configure about specific devices through the Net- work Maps and Network Database sections of the FS6300 NMS.
To add individual devices to the FS6300 NMS:

Figure 44. Add SNMP Device window
Introduction 58

FS6300 NMS User Manual 4 • Configuring and Managing Devices
The Network Maps section of the NMS shows a map of the devices located on the network at various levels.

Figure 45. Network Maps
Geographical Areas Click on a Geographical Area in the main menu tree to view a map of Network Nodes in the NMS.
Right-click on the icon of a Network Node in the main window to view a pull-down menu of options.
Nodes Click on a Network Node in the main menu tree to view a map of Chassis in that node.
Right-click on the icon of a Chassis in the main window to view a pull-down menu of options..
Chassis Click on a Chassis in the main menu tree to view a map of Devices in that chassis.
Right-click on the icon of a Device in the main window to view a pull-down menu of options..
Slots/Devices Click on a Device in the main menu tree to view a map of Ports in that device.
Right-click on the icon of a Port in the main window to view a pull-down menu of options.
Ports/Interfaces Right-click on a port to configure its link or set it to be managed or unmanaged.
subnet of GA1-NN1-<CH2> or GA1-NN1-CH2
NN 1 NN 2 CHASSIS 1 NN 3 CHASSIS 1
(Can be represented as)
NMS
CHASSIS 1 CHASSIS 2
GA 2
NN 1 NN 5 CHASSIS 1 CHASSIS 2 CHASSIS 3 CHASSIS 4
Figure 46. Container IDs in the NMS
Working with Network Maps 59

FS6300 NMS User Manual 4 • Configuring and Managing Devices
Operators may want to reboot a device or save the current configuration to memory, in case problems arise in the system. To reach the Operator Actions menu, right-click on the Device icon and select Operator Action.
Record the current configuration To save the current configuration of a device to memory:

Figure 47. Record Current Configuration
Reboot the device To reboot a chassis or card:

Figure 48. Hard Reset
Managing Operator Actions 60

FS6300 NMS User Manual 4 • Configuring and Managing Devices
The Hard Reset process will reset ALL of the system’s values to the original factory settings. After resetting these values, the sys- tem will continue to function the same until the system is reboo- ted.
Set the factory default configuration To set the factory default configuration for a device:

Figure 49. Set Factory Default Configuration
The Hard Reset process will reset ALL of the system’s values to the original factory settings. After resetting these values, the sys- tem will continue to function the same until the system is reboo- ted.
Managing Operator Actions 61

FS6300 NMS User Manual 4 • Configuring and Managing Devices
See the following chapters for detailed information on configuring specific cards:
The following sections include procedures that are the same for all cards:
Viewing Events and Alerts Events are occurrences in the network, such as the discovery of an element, status update of an element, or a filure of an element. Alarms/Alerts are a result of events in the network and they represent failures that require immediate attention.
To view a color-coded chart that shows the amount of alarms and severity of alarms for the card, select Events and Alerts from the card’s configuration menu.

Figure 50. Card Events and Alerts
Configuring Cards 62

FS6300 NMS User Manual 4 • Configuring and Managing Devices
Exporting the Configuration To save a card configuration:

Figure 51. FS6300 Export Card Configuration window
The window displays a “COMPLETED” status message after the system successfully exports the configuration file. Exported files are on the NMS in the directory: /opt/FS6300/Server/<nms version>/ExportedFiles/Device- Config/<card type>.

Figure 52. Export Complete
Configuring Cards 63

FS6300 NMS User Manual 4 • Configuring and Managing Devices
Importing the Configuration To load a configuration file for a card:

Figure 53. Import Card Configuration

Figure 54. Successful Import
Configuring Cards 64

FS6300 NMS User Manual 4 • Configuring and Managing Devices
Viewing/Modifying System Log Configuration Select System Log from the card’s configuration menu to view and modify syslog information. If you only want to view the syslog configuration, click on View SystemLog Configuration in the System Log window. To configure the syslog information, click on Modify SystemLog Configuration in the menu tree in the Syslog window.

Figure 55. Modify System Log
Changing Alarm Status To change the alarm status of a card:

Figure 56. Set System Card Alarm Status
Configuring Cards 65

FS6300 NMS User Manual 4 • Configuring and Managing Devices
Viewing LEDs To view the real-time LEDs of a chassis or card:
Configuring Cards 66


The Patton Model 2616RC is a digital cross-connect with 16 T1/E1 ports. There are several ways to reach the configuration menu for the 2616RC card:
The best way to reach the configuration menu for a card is to select the card’s chassis in the menu tree, then right-click on the card’s icon in the main window.
The following options are available in the pull-down menu for the 2616RC card:

Figure 57. 2616RC Configuration Menu
Introduction 68

Click on Card Front Panel GUI to view the front panel of the card in real-time.

Figure 58. 2616RC Front Panel LEDs
Click on Card System Configuration to configure system parameters. You can also view the system status, eth- ernet status, system parameters, SNMP and HTTP Parameters, and system status details.
Modify System Parameters If you only want to view the system parameters, click on View System Parameters in the Card System Config- uration window.
To configure the card system, click on Modify System Parameters in the menu tree in the Card System Con- figuration window (see Figure 57 on page 68).
Viewing the Front Panel 69


Figure 59. Modify 2616RC Card System Parameters
View System Status Click on View System Status in the Card System Configuration window to see an overview of the physical sta- tus of the card and the system status. View System Status shows information about the handle switches, front/ rear LEDs, alarm and clock LEDs, and the board temperature.
View System Status Details Click on View System Status Details in the Card System Configuration window to see information on CPU statistics, Message Block statistics, Memory statistics, Manufacturer details, and the Enclosure System temper- ature.
View Ethernet Status Click on View Ethernet Status in the Card System Configuration window to see the LEDs and speeds of the card’s Ethernet ports.
View SNMP and HTTP Parameters Click on View SNMP and HTTP Parameters in the Card System Configuration window to see the SNMP version and passwords.
Configuring the Card System 70

Click on Ethernet Overview to configure Ethernet settings. You can also view Ethernet statistics.
Modify Ethernet Parameters If you only want to view the Ethernet parameters, click on View Ethernet Parameters in the Ethernet Over- view window.
To configure the Ethernet settings, click on Modify Ethernet Parameters in the menu tree in the Ethernet Overview window (see Figure 60).

Figure 60. Modify 2616RC Ethernet Parameters
View Ethernet Statistics Click on View Ethernet Statistics in the Ethernet Overview window to view statistics for the Ethernet ports on the device, such as errors and frame stats.
Configuring Ethernet Settings 71

You may configure a host and routes for the 2616RC through the FS6300 NMS. The IP Overview window shows details for routing destinations, and includes information for gateway, cost, interface, protocol, and state of each route.

Figure 61. 2616RC IP Overview
The table in the IP Overview window shows a list of defined routes for the 2616RC, and includes the follow- ing information for each entry:
– local(1)—Added by the DACS to support an interface.
– user(2)—Added by an administrator on the IP Routing Information table or via SNMP managemen
tools.
– rip(4)—Learned via reception of RIP packet.
– icmp(5)—Learned via reception of ICMP packet
Configuring IP Routing 72

Add Routes To add an IP route to the 2616RC:

Figure 62. Add a New Route for 2616RC
Modify Routes To modify an existing IP route for the 2616RC:

Figure 63. Modifying a Route for 2616RC
Configuring IP Routing 73

Click on PPP Configuration to view PPP links for the card. You may also modify the link configuration and default packet settings for PPP links.
Modify PPP Link Configuration To configure PPP links for the card:

Figure 64. PPP Link Configuration
– PPP Protocol: The desired kind of PPP protocol.
– Authentication Technique: The login technique to use for authentication.
Configuring PPP 74

– Authentication Side: The side of the link which will be authenticating.
side if the remote machine is authenticating.
– MRU: The setting for Maximum Receive Unit (MRU), used for the PPP negotiation.
– IP Address: The IP address that will be used for the PPP link.
– IP Mask: The IP mask that will be used for the PPP link.
– IP Compression: Set whether Van Jacobson (vj-tcp(2)) header compression is used or not (none(1)).
– IP Force Next Hop: The IP address of the interface, which should be the next hop for the packets—fast
the PPP negotiations will desire link compression but may disable the compression due the other end of the link not accepting link compression. When disabled the PPP negotiations will force no compression on the PPP link.
– Allow Magic Number Negotiation: Determines if magic number negotiation should be done.
Reference Guide for more information on IP filtering.
routing · Configuring PPP 75

Modify Default Packet Settings You may modify the default PPP settings that each PPP link will take when first initialized. See “Modify PPP Link Configuration” on page 74 for modifying settings for individual links.
To modify default packet settings for PPP links:

Figure 65. PPP Default Packet Settings
– Authentication Technique: The login technique to use for authentication.
– Authentication Side: The side of the link which will be authenticating.
side if the remote machine is authenticating.
– MRU: The setting for Maximum Receive Unit (MRU), used for the PPP negotiation.
Configuring PPP 76

the PPP negotiations will desire link compression but may disable the compression due the other end of the link not accepting link compression. When disabled the PPP negotiations will force no compression on the PPP link.
– Allow Magic Number Negotiation: Determines if magic number negotiation should be done.
– Compression: If none(1), then the local node will not attempt to negotiate any IP compression option.
Otherwise, the local node will attempt to negotiate compression mode. Changing this option will have effect when the link restarts.
Configuring PPP 77

Click on T1E1 Port Configuration to view T1/E1 links for the card. Select an entry in the table to configure line interfaces, test settings, and channel assignments for T1/E1 ports.
View Configuration In the T1-E1 Port Configuration window for the selected link, click on View Configuration. If there are alarms for the link, click on Alarms Present to view the alarm details for the link.
Modify Line Interface Settings

Figure 66. T1/E1 Link Configuration window
– Circuit ID: The transmission vendor’s circuit identifier, for the purpose of facilitating troubleshooting.
– Line Type: the type of DS1 Line implemented on this circuit. The type of circuit affects the number of
bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. Select fromt he following values:
Configuring the T1/E1 Ports 78

– Line Coding: The type of Zero Code Suppression used on the link.
equalization set for more. Short haul signals require less equalization.
– Receiver Sensitivity: The minimum voltage at which the WAN port will sense that the signal is avail-
able. This variable is only used if the Receiver Equalization is set to ON.
– Yellow Alarm Format: The standard used to transmit and identify the Yellow Alarm.
– Fdl: implementation of FDL is being used, if any. FDL applies only to T1 circuits.
If one of the E1 line types has been selected, set Fdl to dsx1Fdl-none(8).
Configuring the T1/E1 Ports 79


Figure 67. T1/E1 Test Settings
– Force Yellow Alarm: The standard used to transmit and identify the Yellow Alarm.
– Loopback Configuration: The loopback configuration of the DS1 interface.
– Send Code: The type of code is being sent across the DS1 interface by the device.
– Error Injection: Force an output error to see if the other end detects it.
Configuring the T1/E1 Ports 80
Modify Test Settings


Figure 68. T1/E1 Channel Assignment
In the Modify Channel Assignment section of the T1/E1 Link Configuration window, you can change selected DS0 channels to carry in-band management information over Frame Relay or PPP links. You can use the buttons at the top of the window to modify all 30 timeslots at once. Or, you can use the 30 drop-down menus to modify selected timeslots individually. Click Submit to apply your changes for individual links.
View Line Status There are two types of line status statistics that you may view in the T1/E1 Link Configuration window – Near End Line Status and Far End Line Status.
Configuring the T1/E1 Ports 81
Modify Channel Assignments

Click on T1E1 Reports from the card’s configuration menu to view and print different reports about the activ- ity, line interface settings, and test settings of T1/E1 links on the 2616RC card.
Click the Print button to send the report to a printer on your network.
Click the Export to Excel button to send the report to Microsoft Excel to save in a spreadsheet.

Figure 69. 2616RC T1/E1 Reports
Click on Display T1E1 Map Layer from the card’s configuration menu to show a map of all the T1/E1 ports on the card. Right-click on a port in the map to configure its link. See “Configuring the T1/E1 Ports” on page 78 for more details.

Figure 70. 2616RC T1/E1 Port Map
Viewing T1/E1 Reports 82


The Patton Model 3096RC is a G.SHDSL TDM Concentrator with 16 G.SHDSL ports. There are several ways to reach the configuration menu for the 3096RC card:
The best way to reach the configuration menu for a card is to select the card in the main menu tree, then right- click on the card’s icon in the main window.
The following options are available in the pull-down menu for the 3096RC card:

Figure 71. 3096RC Configuration Menu
Introduction 84

Click on Card Front Panel GUI to view the front panel of the card in real-time.

Figure 72. 3096RC Front Panel LEDs
Click on Card System Configuration to configure system parameters. You can also view the system status, eth- ernet status, system parameters, SNMP and HTTP Parameters, and system status details.
Modify System Parameters If you only want to view the system parameters, click on View System Parameters in the Card System Config- uration window.
To configure the card system, click on Modify System Parameters in the menu tree in the Card System Con- figuration window (see Figure 71 on page 84).
Viewing the Front Panel 85

Figure 73. Modify Card System Parameters
View System Status Click on View System Status in the Card System Configuration window to see an overview of the physical sta- tus of the card and the system status. View System Status shows information about the handle switches, front/ rear LEDs, alarm and clock LEDs, and the board temperature.
View System Status Details Click on View System Status Details in the Card System Configuration window to see information on CPU statistics, Message Block statistics, Memory statistics, Manufacturer details, and the Enclosure System temper- ature.
View Ethernet Status Click on View Ethernet Status in the Card System Configuration window to see the LEDs and speeds of the card’s Ethernet ports.
View SNMP and HTTP Parameters Click on View SNMP and HTTP Parameters in the Card System Configuration window to see the SNMP version and passwords.
Configuring the Card System 86

Click on Ethernet Overview to configure Ethernet settings. You can also view Ethernet statistics.
Modify Ethernet Parameters If you only want to view the Ethernet parameters, click on View Ethernet Parameters in the Ethernet Over- view window.
To configure the Ethernet settings, click on Modify Ethernet Parameters in the menu tree in the Ethernet Overview window (see Figure 74).

Figure 74. Modify Ethernet Parameters
View Ethernet Statistics Click on View Ethernet Statistics in the Ethernet Overview window to view statistics for the Ethernet ports on the device, such as errors and frame stats.
Configuring Ethernet Settings 87

Click on G.SHDSL Port Configuration in the pull-down menu to bring up the G.SHDSL window. The G.SHDSL window shows the number of G.SHDSL ports available, linked ports, failed ports, training ports, ports in test mode, and ports downloaded.

Figure 75. 3096RC G.SHDSL window
Activating/Deactivating All Ports Click the Activate All Ports button to train all of the G.SHDSL ports on the card.
Click the Deactivate All Ports button to turn off all of the G.SHDSL ports on the card.
Configuring G.SHDSL Ports 88

Configuring Individual Ports To configure an individual port, click on the port in the table to bring up the Port Configuration window. From the port Configuration window, you can edit the port’s configuration, view port information, edit CO/ CPE options, and edit the line rate.
Click on Edit Configuration in the menu tree of the Port Configuration window. Circuit ID, Desired State, and Test Mode are configurable.

Figure 76. 3096RC Edit G.SHDSL Configuration
View Port Information Click on Fifo Info and DataPath Info in the menu tree of the Port Configuration window to view Fifo and Data Path errors and up times.
Configuring G.SHDSL Ports 89
Edit Configuration

Edit CO/CPE Options Click on CO Options or CPE Options in the menu tree of the Port Configuration window to view the line provision rate, clock mode, payload rate, I-bits, annex type, transmit power, and EOC status.

Figure 77. 3096RC Edit CO Options
To edit the CO/CPE options for a port:
– Payload Rate: Select a rate fromt he drop-down menu. See “Determine Best Payload Rate” on page 91.
– Annex Type: Select Annex-A for North America or Annex-B for outside North America.
– Transmit Power: Select a value between +1–6dB to -1–6dB from the drop-down menu.
– Enable EOC: Select Yes (to enable EOC) or No (to disable EOC) from the drop-down menu.
Configuring G.SHDSL Ports 90

Determine Best Payload Rate Click on Line Provision in the menu tree of the Port Configuration window to determine the best payload rate for the port. The Line Provision tool works by resolving line length and line quality. The CO interprets line probe messages from the CPE and calculates a worst-case payload value. The worst-case value determines the highest payload rate the CO and CPE can acheive without errors.

Figure 78. 3096RC Line Provision Tool
Click the Calculate Best Line Rate button to determine the best payload rate.
A status message will display when the tool is finished. Click OK.
Configuring G.SHDSL Ports 91

Click on G.SHDSL Report to view different reports about port details, CO/CPE details, data path, and Fifo information for the G.SHDSL ports on the 3096RC card.
Click the Print button to send the report to a printer on your network.
Click the Export to Excel button to send the report to Microsoft Excel to save in a spreadsheet.

Figure 79. 3096RC G.SHDSL Reports
Viewing G.SHDSL Reports 92

ou may configure a host and routes for the 3096RC through the FS6300 NMS. The IP Overview window shows details for routing destinations, and includes information for gateway, cost, interface, protocol, and state of each route.
Figure 80. 3096RC IP Overview
The table in the IP Overview window shows a list of defined routes for the 3096RC, and includes the follow- ing information for each entry:
– local(1)—Added by the DACS to support an interface.
– user(2)—Added by an administrator on the IP Routing Information table or via SNMP managemen
tools.
– rip(4)—Learned via reception of RIP packet.
– icmp(5)—Learned via reception of ICMP packet
Configuring IP Routing 93

Add Routes To add an IP route to the 3096RC:
Figure 81. Add a New Route for 3096RC
Modify Routes To modify an existing IP route for the 3096RC:
Figure 82. Modifying a Route for 3096RC
Configuring IP Routing 94

Click on PPP Configuration to view PPP links for the card. You may also modify the link configuration and default packet settings for PPP links.
Modify PPP Link Configuration To configure PPP links for the card:
Figure 83. PPP Link Configuration
– PPP Protocol: The desired kind of PPP protocol.
– Authentication Technique: The login technique to use for authentication.
Configuring PPP 95

– Authentication Side: The side of the link which will be authenticating.
side if the remote machine is authenticating.
– MRU: The setting for Maximum Receive Unit (MRU), used for the PPP negotiation.
– IP Address: The IP address that will be used for the PPP link.
– IP Mask: The IP mask that will be used for the PPP link.
– IP Compression: Set whether Van Jacobson (vj-tcp(2)) header compression is used or not (none(1)).
– IP Force Next Hop: The IP address of the interface, which should be the next hop for the packets—fast
the PPP negotiations will desire link compression but may disable the compression due the other end of the link not accepting link compression. When disabled the PPP negotiations will force no compression on the PPP link.
– Allow Magic Number Negotiation: Determines if magic number negotiation should be done.
tor’s Reference Guide for more information on IP filtering.
routing · Configuring PPP 96

Modify Default Packet Settings You may modify the default PPP settings that each PPP link will take when first initialized. See “Modify PPP Link Configuration” on page 95 for modifying settings for individual links.
To modify default packet settings for PPP links:
Figure 84. PPP Default Packet Settings
– Authentication Technique: The login technique to use for authentication.
– Authentication Side: The side of the link which will be authenticating.
side if the remote machine is authenticating.
– MRU: The setting for Maximum Receive Unit (MRU), used for the PPP negotiation.
Configuring PPP 97

the PPP negotiations will desire link compression but may disable the compression due the other end of the link not accepting link compression. When disabled the PPP negotiations will force no compression on the PPP link.
– Allow Magic Number Negotiation: Determines if magic number negotiation should be done.
– Compression: If none(1), then the local node will not attempt to negotiate any IP compression option.
Otherwise, the local node will attempt to negotiate compression mode. Changing this option will have effect when the link restarts.
Configuring PPP 98

Click on T1E1 Port Configuration to view T1/E1 links for the card. Select an entry in the table to configure line interfaces, test settings, and channel assignments for T1/E1 ports.
View Configuration In the T1-E1 Port Configuration window for the selected link, click on View Configuration. If there are alarms for the link, click on Alarms Present to view the alarm details for the link.
Modify Line Interface Settings
Figure 85. T1/E1 Link Configuration window
– Circuit ID: The transmission vendor’s circuit identifier, for the purpose of facilitating troubleshooting.
– Line Type: the type of DS1 Line implemented on this circuit. The type of circuit affects the number of
bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. Select fromt he following values:
Configuring the T1/E1 Ports 99

– Line Coding: The type of Zero Code Suppression used on the link.
equalization set for more. Short haul signals require less equalization.
– Receiver Sensitivity: The minimum voltage at which the WAN port will sense that the signal is avail-
able. This variable is only used if the Receiver Equalization is set to ON.
– Yellow Alarm Format: The standard used to transmit and identify the Yellow Alarm.
– Fdl: implementation of FDL is being used, if any. FDL applies only to T1 circuits.
If one of the E1 line types has been selected, set Fdl to dsx1Fdl-none(8).
Configuring the T1/E1 Ports 100

Figure 86. T1/E1 Test Settings
– Force Yellow Alarm: The standard used to transmit and identify the Yellow Alarm.
– Loopback Configuration: The loopback configuration of the DS1 interface.
– Send Code: The type of code is being sent across the DS1 interface by the device.
– Error Injection: Force an output error to see if the other end detects it.
Configuring the T1/E1 Ports 101
Modify Test Settings

Figure 87. T1/E1 Channel Assignment
In the Modify Channel Assignment section of the T1/E1 Link Configuration window, you can change selected DS0 channels to carry in-band management information over Frame Relay or PPP links. You can use the buttons at the top of the window to modify all 30 timeslots at once. Or, you can use the 30 drop-down menus to modify selected timeslots individually. Click Submit to apply your changes for individual links.
View Line Status There are two types of line status statistics that you may view in the T1/E1 Link Configuration window – Near End Line Status and Far End Line Status.
Configuring the T1/E1 Ports 102
Modify Channel Assignments

Click on T1E1 Reports to view and print different reports about the activity, line interface settings, and test settings of T1/E1 links on the 3096RC card.
Click the Print button to send the report to a printer on your network.
Click the Export to Excel button to send the report to Microsoft Excel to save in a spreadsheet.

Figure 88. 3096RC T1/E1 Reports
Click on Display T1E1 Map Layer to show a map of all the T1/E1 ports on the card. Right-click on a port in the map to configure its link. See “Configuring the T1/E1 Ports” on page 99 for more details.

Figure 89. 3096RC T1/E1 Port Map
Viewing T1/E1 Reports 103

Click on Display G.SHDSL Map Layer to show a map of all the G.SHDSL ports on the card. Right-click on a port in the map to configure its link. See “Configuring G.SHDSL Ports” on page 88 for more details.

Figure 90. 3096RC G.SHDSL Port Map
Viewing the G.SHDSL Map Layer 104


The Patton Model 3196RC is a TDM concentrator with 16 iDSL ports. There are several ways to reach the configuration menu for the 3196RC card:
The best way to reach the configuration menu for a card is to select the card in the main menu tree, then right- click on the card’s icon in the main window.
The following options are available in the pull-down menu for the 3196RC card:

Figure 91. 3196RC Configuration Menu
Introduction 106

Click on Card Front Panel GUI to view the front panel of the card in real-time.

Figure 92. 3196RC Front Panel LEDs
Click on Card System Configuration to configure system parameters. You can also view the system status, eth- ernet status, system parameters, SNMP and HTTP Parameters, and system status details.
Modify System Parameters If you only want to view the system parameters, click on View System Parameters in the Card System Config- uration window.
To configure the card system, click on Modify System Parameters in the menu tree in the Card System Con- figuration window (see Figure 93 on page 108).
Viewing the Front Panel 107

Figure 93. Modify Card System Parameters
View System Status Click on View System Status in the Card System Configuration window to see an overview of the physical sta- tus of the card and the system status. View System Status shows information about the handle switches, front/ rear LEDs, alarm and clock LEDs, and the board temperature.
View System Status Details Click on View System Status Details in the Card System Configuration window to see information on CPU statistics, Message Block statistics, Memory statistics, Manufacturer details, and the Enclosure System temper- ature.
View Ethernet Status Click on View Ethernet Status in the Card System Configuration window to see the LEDs and speeds of the card’s Ethernet ports.
View SNMP and HTTP Parameters Click on View SNMP and HTTP Parameters in the Card System Configuration window to see the SNMP version and passwords.
Configuring the Card System 108

Click on Ethernet Overview to configure Ethernet settings. You can also view Ethernet statistics.
Modify Ethernet Parameters If you only want to view the Ethernet parameters, click on View Ethernet Parameters in the Ethernet Over- view window.
To configure the Ethernet settings, click on Modify Ethernet Parameters in the menu tree in the Ethernet Overview window (see Figure 94).
Figure 94. Modify Ethernet Parameters
View Ethernet Statistics Click on View Ethernet Statistics in the Ethernet Overview window to view statistics for the Ethernet ports on the device, such as errors and frame stats.
Configuring Ethernet Settings 109

Click on iDSL Port Configuration in the pull-down menu to bring up the iDSL window. The iDSL window shows the number of iDSL ports available, linked ports, failed ports, training ports, and ports in test mode.

Figure 95. 3196RC iDSL window
Activating/Deactivating All Ports Click the Activate All Ports button to train all of the iDSL ports on the card.
Click the Deactivate All Ports button to turn off all of the iDSL ports on the card.
Configuring iDSL Ports 110

Configuring Individual Ports To configure an individual port, click on the port in the table to bring up the Port Configuration window. From the Port Configuration window, you can edit the port’s configuration, view port information, edit CPE options, and modify alarm thresholds.
Click on Edit Configuration in the menu tree of the Port Configuration window. Circuit ID, Desired State, Test Mode and Test Pattern are configurable.

Figure 96. 3196RC Edit iDSL Configuration
Configuring iDSL Ports 111
Edit Configuration

View Port Information Click on iDSL Port Status and Statistics in the menu tree of the Port Configuration window to view erros and up times for the selected port.
Edit CPE Options Click on Modify CPE Information in the menu tree of the Port Configuration window to edit the options for the CPE, such as the serial rate, DTE test mode, and front panel switches.
To edit the CPE options for a port:
rate19-2k(0) for serial rate of 19200 bps
rate32k(1) for serial rate of 32000 bps
rate56k(1) for serial rate of 56000 bps
rate64k(1) for serial rate of 64000 bps
rate128k(1) for serial rate of 128000 bps
rate144k(1) for serial rate of 144000 bps
– Front Panel Switches: Disable or enable front panel switches for the CPE.
– DTE Test Mode: Enable or disable the CPE from initiating and responding to test patterns.
– User ID: Enter a new User ID for the remote CPE.
Configuring iDSL Ports 112

Modify iDSL Alarm Thresholds You may modify the number of errored seconds and unavailable seconds for which an alarm condition will be triggered for a selected iDSL port on the 3196RC.
To modify the iDSL alarm threshold:

Figure 97. 3196RC Modify iDSL Alarm Thresholds
– Errored Seconds Alarm Threshold (per interval)—Enter a number of errored seconds that will trigger
an alarm.
– Severely Errored Seconds Alarm Threshold (per interval) - Enter a number of errored seconds that will
trigger an alarm.
– Unavailable Seconds Alarm Threshold (per interval) - Enter a number of unavailable seconds that will
trigger an alarm.
Click on iDSL Report to view different reports about port details, status, statistics, alarm threshold, and CPE details for the iDSL ports on the 3196RC card. Click the Print button to send the report to a printer on your network. Click the Export to Excel button to send the report to Microsoft Excel to save in a spreadsheet.

Figure 98. 3196RC iDSL Reports
Viewing iDSL Reports 113

ou may configure a host and routes for the 3196RC through the FS6300 NMS. The IP Overview window shows details for routing destinations, and includes information for gateway, cost, interface, protocol, and state of each route.
Figure 99. 3196RC IP Overview
The table in the IP Overview window shows a list of defined routes for the 3196RC, and includes the follow- ing information for each entry:
– local(1)—Added by the DACS to support an interface.
– user(2)—Added by an administrator on the IP Routing Information table or via SNMP managemen
tools.
– rip(4)—Learned via reception of RIP packet.
– icmp(5)—Learned via reception of ICMP packet
Configuring IP Routing 114

Add Routes To add an IP route to the 3196RC:
Figure 100. Add a New Route for 3196RC
Modify Routes To modify an existing IP route for the 3196RC:
Figure 101. Modifying a Route for 3196RC
Configuring IP Routing 115

Click on PPP Configuration to view PPP links for the card. You may also modify the link configuration and default packet settings for PPP links.
Modify PPP Link Configuration To configure PPP links for the card:
Figure 102. PPP Link Configuration
– PPP Protocol: The desired kind of PPP protocol.
– Authentication Technique: The login technique to use for authentication.
Configuring PPP 116

– Authentication Side: The side of the link which will be authenticating.
side if the remote machine is authenticating.
– MRU: The setting for Maximum Receive Unit (MRU), used for the PPP negotiation.
– IP Address: The IP address that will be used for the PPP link.
– IP Mask: The IP mask that will be used for the PPP link.
– IP Compression: Set whether Van Jacobson (vj-tcp(2)) header compression is used or not (none(1)).
– IP Force Next Hop: The IP address of the interface, which should be the next hop for the packets—fast
the PPP negotiations will desire link compression but may disable the compression due the other end of the link not accepting link compression. When disabled the PPP negotiations will force no compression on the PPP link.
– Allow Magic Number Negotiation: Determines if magic number negotiation should be done.
tor’s Reference Guide for more information on IP filtering.
routing · Configuring PPP 117

Modify Default Packet Settings You may modify the default PPP settings that each PPP link will take when first initialized. See “Modify PPP Link Configuration” on page 116 for modifying settings for individual links.
To modify default packet settings for PPP links:
Figure 103. PPP Default Packet Settings
– Authentication Technique: The login technique to use for authentication.
– Authentication Side: The side of the link which will be authenticating.
side if the remote machine is authenticating.
– MRU: The setting for Maximum Receive Unit (MRU), used for the PPP negotiation.
Configuring PPP 118

the PPP negotiations will desire link compression but may disable the compression due the other end of the link not accepting link compression. When disabled the PPP negotiations will force no compression on the PPP link.
– Allow Magic Number Negotiation: Determines if magic number negotiation should be done.
– Compression: If none(1), then the local node will not attempt to negotiate any IP compression option.
Otherwise, the local node will attempt to negotiate compression mode. Changing this option will have effect when the link restarts.
Configuring PPP 119

Click on T1E1 Port Configuration to view T1/E1 links for the card. Select an entry in the table to configure line interfaces, test settings, and channel assignments for T1/E1 ports.
View Configuration In the T1-E1 Port Configuration window for the selected link, click on View Configuration. If there are alarms for the link, click on Alarms Present to view the alarm details for the link.
Modify Line Interface Settings
Figure 104. T1/E1 Link Configuration window
– Circuit ID: The transmission vendor’s circuit identifier, for the purpose of facilitating troubleshooting.
– Line Type: the type of DS1 Line implemented on this circuit. The type of circuit affects the number of
bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. Select fromt he following values:
Configuring the T1/E1 Ports 120

– Line Coding: The type of Zero Code Suppression used on the link.
equalization set for more. Short haul signals require less equalization.
– Receiver Sensitivity: The minimum voltage at which the WAN port will sense that the signal is avail-
able. This variable is only used if the Receiver Equalization is set to ON.
– Yellow Alarm Format: The standard used to transmit and identify the Yellow Alarm.
– Fdl: implementation of FDL is being used, if any. FDL applies only to T1 circuits.
If one of the E1 line types has been selected, set Fdl to dsx1Fdl-none(8).
Configuring the T1/E1 Ports 121

Figure 105. T1/E1 Test Settings
– Force Yellow Alarm: The standard used to transmit and identify the Yellow Alarm.
– Loopback Configuration: The loopback configuration of the DS1 interface.
– Send Code: The type of code is being sent across the DS1 interface by the device.
– Error Injection: Force an output error to see if the other end detects it.
Configuring the T1/E1 Ports 122
Modify Test Settings

Figure 106. T1/E1 Channel Assignment
In the Modify Channel Assignment section of the T1/E1 Link Configuration window, you can change selected DS0 channels to carry in-band management information over Frame Relay or PPP links. You can use the buttons at the top of the window to modify all 30 timeslots at once. Or, you can use the 30 drop-down menus to modify selected timeslots individually. Click Submit to apply your changes for individual links.
View Line Status There are two types of line status statistics that you may view in the T1/E1 Link Configuration window – Near End Line Status and Far End Line Status.
Configuring the T1/E1 Ports 123
Modify Channel Assignments

Click on T1E1 Reports to view and print different reports about the activity, line interface settings, and test settings of T1/E1 links on the 3196RC card.
Click the Print button to send the report to a printer on your network.
Click the Export to Excel button to send the report to Microsoft Excel to save in a spreadsheet.
Figure 107. 3196RC T1/E1 Reports
Click on Display T1E1 Map Layer to show a map of all the T1/E1 ports on the card. Right-click on a port in the map to configure its link. See “Configuring the T1/E1 Ports” on page 120 for more details.

Figure 108. 3196RC T1/E1 Port Map
Viewing T1/E1 Reports 124

Click on Display iDSL Map Layer to show a map of all the iDSL ports on the card. Right-click on a port in the map to configure its link. See “Configuring iDSL Ports” on page 110 for more details.

Figure 109. 3196RC iDSL Port Map
Viewing the iDSL Map Layer 125


The Patton Model 6511RC is a matrix switch with Gigabit Ethernet. There are several ways to reach the con- figuration menu for the 6511RC card:
The best way to reach the configuration menu for a card is to select the card in the main menu tree, then right- click on the card’s icon in the main window.
The following options are available in the pull-down menu for the 6511RC card:

Figure 110. 6511RC Configuration Menu
Introduction 127

Click on Card Front Panel GUI to view the front panel of the card in real-time.

Figure 111. 6511RC Front Panel LEDs
Click on Card System Configuration to configure system parameters. You can also view the system status, eth- ernet status, system parameters, SNMP and HTTP Parameters, and system status details.
Modify System Parameters If you only want to view the system parameters, click on View System Parameters in the Card System Config- uration window.
To configure the card system, click on Modify System Parameters in the menu tree in the Card System Con- figuration window (see Figure 112 on page 129).
Viewing the Front Panel 128

Figure 112. Modify Card System Parameters
View System Status Click on View System Status in the Card System Configuration window to see an overview of the physical sta- tus of the card and the system status. View System Status shows information about the handle switches, front/ rear LEDs, alarm and clock LEDs, and the board temperature.
View System Status Details Click on View System Status Details in the Card System Configuration window to see information on CPU statistics, Message Block statistics, Memory statistics, Manufacturer details, and the Enclosure System temper- ature.
View Ethernet Status Click on View Ethernet Status in the Card System Configuration window to see the LEDs and speeds of the card’s Ethernet ports.
View SNMP and HTTP Parameters Click on View SNMP and HTTP Parameters in the Card System Configuration window to see the SNMP version and passwords.
Configuring the Card System 129

Click on Ethernet Overview to configure Ethernet settings. You can also view Ethernet statistics.
Modify Ethernet Parameters If you only want to view the Ethernet parameters, click on View Ethernet Parameters in the Ethernet Over- view window.
To configure the Ethernet settings, click on Modify Ethernet Parameters in the menu tree in the Ethernet Overview window (see Figure 113).
Figure 113. Modify Ethernet Parameters
View Ethernet Statistics Click on View Ethernet Statistics in the Ethernet Overview window to view statistics for the Ethernet ports on the device, such as errors and frame stats.
Configuring Ethernet Settings 130

Click on E1 Link to configure the line interface, alarm status, DS0 settings, and test settings.
Edit Line Interface Settings Click on Line Interface (under Current Configuration) in the menu tree for the E1 Link window, then select the links you want to edit from the TUG3, TUG2, and TU drop-down menus. Make the desired changes, then click Submit.
View Alarm Status Click on Alarm Status (under Current Configuration) in the menu tree for the E1 Link window, then select the links you want to view alarms for from the TUG3, TUG2, and TU drop-down menus.
View Line Statistics You can view Current, Past, and Total Line Statistics for a link. Navigate to Near End Line Statistics > Cur- rent, Near End Line Statistics > History, or Near End Line Statistics > Totals in the menu tree for the E1 Link window, then select the links you want to view from the TUG3, TUG2, and TU drop-down menus.
Configure DS0 Settings Click on DS0 Configuration > Details in the menu tree for the E1 Link window, then select the links you want to configure from the TUG3, TUG2, and TU drop-down menus (see Figure 114 on page 131).

Figure 114. 6511RC DS0 Details
If you only want to enable or disable a few DS0 numbers, select the status from the drop-down menu for each DS0 number you want to change, then click Selective Modify.
If you want to activate all DS0 numbers, click Enable All. If you want to deactivate all DS0 numbers, click Disable All. A status emssage will display. Click OK.
Configuring E1 Links 131

Edit Test Settings Click on Test Configuration in the menu tree for the E1 Link window, then select the links you want to con- figure from the TUG3, TUG2, and TU drop-down menus. Test Configuration > Overview shows informa- tion for SDH, including test settings, line parameters, and test parameters.
Click on Test Configuration > Modify to configure test parameters (see Figure 115 on page 132).

Figure 115. 6511RC E1 Link Test Settings
– dsx1NoLoop(1)—Not in the loopback state. A device that is not capable of performing a loopback on
the interface shall always return this as its value.
– dsx1PayloadLoop(2)—The received signal at this interface is looped through the device. Typically the
received signal is looped back for retransmission after it has passed through the device's framing func- tion.
– dsx1LineLoop(3)—The received signal at this interface does not go through the device (minimum pen-
etration) but is looped back out.
– dsx1OtherLoop(4)—Loopbacks that are not defined here.
Configuring E1 Links 132

ou may configure a host and routes for the 6511RC through the FS6300 NMS. The IP Overview window shows details for routing destinations, and includes information for gateway, cost, interface, protocol, and state of each route.
Figure 116. 6511RC IP Overview
The table in the IP Overview window shows a list of defined routes for the 6511RC, and includes the follow- ing information for each entry:
– local(1)—Added by the DACS to support an interface.
– user(2)—Added by an administrator on the IP Routing Information table or via SNMP managemen
tools.
– rip(4)—Learned via reception of RIP packet.
– icmp(5)—Learned via reception of ICMP packet
Configuring IP Routing 133

Adding Routes To add an IP route to the 6511RC:
Figure 117. Add a New Route for 6511RC
Modifying Routes To modify an existing IP route for the 6511RC:
Figure 118. Modifying a Route for 6511RC
Configuring IP Routing 134

Click on SDH Configuration to bring up the SDH Configuration window to view and modify SDH inter- faces and paths.
Configuring SDH Interfaces To configure SDH interfaces:

Figure 119. 6511RC SDH Interface Configuration
Configuring SDH 135

– sonetNoLoop(0)—Not in the loopback state. The 6511RC WAN interface has not initiated or is not
under a diagnostic loop.
– sonetFacilityLoop(1)—The received signal at this interface is looped back out through the transmitter
section in the return direction.
– sonetTerminalLoop(2)—The signal that is about to be transmitted is connected to the associated
incoming receiver.
– • sonetOtherLoop(3)—Data arriving at the 6511RC H.110 interface is looped back to the originating
device.
Configuring SDH Paths To configure SDH paths:

Figure 120. 6511RC SDH Path Configuration
Configuring SDH 136

Configuring SDH Mapper The SDH Mapper allows you to configure the E1 payload timing with regard to SDH timing.To configure the SDH Mapper:

Figure 121. 6511RC SDH Mapper Configuration
Viewing Alarm Status To view SDH alarms, click on Alarm Status in the menu tree of the SDH Configuration window. Hover the mouse pointer over an LED (Section, Line, or Path) to view the alarm status.
Viewing Statistics To view SDH statistics, click on Near End Statistics or Far End Statistics in the menu tree of the SDH Con- figuration window. Click on an LED in the Current column to edit the Stats Refresh Rate. Click on an LED in the History column to view past details.
Configuring SDH 137

Click on Display E1 Link VC(#) to show a map of all the E1 links on a TUG. To edit a link, right-click on the E1 link icon that you want to edit and select E1 Port Link Configuration. (See “Configuring E1 Links” on page 131).

Figure 122. 6511RC E1 Link Map
Viewing E1Link Layers 138


FS6300 NMS User Manual 9 • Configuring Chassis
To configure a chassis, navigate to Network Maps > Geographical Area > Network Node in the menu tree on the left side of the screen. Right-click on a chassis icon in the main window to display the configuration menu for the chassis.
The following options are available in the pull-down menu for a chassis:

Figure 123. Chassis Configuration Menu
Introduction 140

FS6300 NMS User Manual 9 • Configuring Chassis
Click on Chassis Unit GUI to view the front panels of all of the cards in the chassis in real-time.

Figure 124. Chassis LEDs
Viewing the Chassis LEDs 141

FS6300 NMS User Manual 9 • Configuring Chassis
Click on Display Card Layer to view a map of all of the cards in the chassis. Right-click on a card to configure to view it’s configuration menu.

Figure 125. Chassis Card Layer Map
Viewing the Card Layer Map 142


FS6300 NMS User Manual 10 • Contacting Patton for assistance
This chapter contains the following information:
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.
Patton support headquarters in the USA • Online support: available at www.patton.com
Alternate Patton support for Europe, Middle East, and Africa (EMEA) • Online support: available at www.patton-inalp.com
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship- ment. All of our products are backed by a comprehensive warranty program.
Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod- uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work- manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.
Introduction 144

FS6300 NMS User Manual 10 • Contacting Patton for assistance
Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro- phes may require replacement.
Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.
Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.
RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.
Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.
Warranty Service and Returned Merchandise Authorizations (RMAs) 145