EN
Patton electronic logo
Official user manual

Patton electronic 1001MC

288 pages·10.4 MB·Card Game·PDF·ENDEFRITNLJA
Patton electronic 1001MC
Table of Contents 780 sections Contents · About this guide · Audience · Structure · … ShowHide
Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 1 of the Patton electronic 1001MC user manual — 07M1001MC
Page 1 · click to enlarge
Page 1

Model 1001MC

NetLink™

SNMP Management Card

Operations Guide

Patton electronic 1001MC — Model 1001MC diagram (page 1)
Fig. 1 · Model 1001MC

Sales Office:

Technical Support:

E-mail:

support@patton.com

WWW:

www.patton.com

Document Number:

022021U Rev. F

Part Number:

07M1001MC

Revised:

+1 (301) 975-1000 · +1 (301) 975-1007 · May 19, 2008

Page 2 of the Patton electronic 1001MC user manual
Page 2 · click to enlarge
Page 2

Patton Electronics Company, Inc.

7622 Rickenbacker Drive Gaithersburg, MD 20879 USA

tel+1 (301) 975-1000 fax: +1 (301) 869-9293 support: +1 (301) 975-1007
urlwww.patton.com e-mail: support@ patton.com

Copyright © 2008, Patton Electronics Company. All rights reserved.

are trademarks of Patton Electronics Company. All other trademarks presented in this document are the property of their respective owners.

The information contained in this document is not designed or intended for use as critical components in human life-support systems, equipment used in hazardous environments, or nuclear control systems. Patton Electronics Company disclaims any express or implied warranty of fitness for such uses.

The information in this document is subject to change without notice. Patton Elec- tronics assumes no liability for errors that may appear in this document.

Any software described in this document is furnished under license and may be used or copied only in accordance with the terms of such license.

Show 8 more labels / short text on this page
Copyright Statement · Trademark Statement · The terms · NetLink · , · KiloModem · , and · MegaLink-I
Page 3 of the Patton electronic 1001MC user manual — Table of Contents
Page 3 · Contents
Contents

Contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 6 of the Patton electronic 1001MC user manual — Structure
Page 6 · click to enlarge
Page 6

About this guide

This guide describes installing and operating a Patton Electronics 1001MC NetLink™ SNMP Management Card. This section describes the following:

  • Who should use this guide (see “Audience” )
  • How this document is organized (see “Structure” )
  • Typographical conventions and terms used in this guide (see “Typographical conventions used in this document” on page 7)

Audience

This guide is intended for use by qualified systems administrators and network engineers to configure and manage the Patton Electronics Model 1001MC and NetLink™ modems. Knowledge of basic networking con- cepts is assumed

Structure

This guide contains the following chapters:

  • Chapter 1 (on page 10) introduces the Model 1001MC and provides an overview of the management window
  • Chapter 2 (on page 15) describes how to install the Model 1001MC
  • Chapter 3 (on page 36) describes how to boot the Model 1001MC, install cables, set up the address range for NetLink modems, log into the HTTP/HTML administration pages, and save HTTP/HTML object changes
  • Chapter 4 (on page 47) describes how to manage a 1092ARC NetLink modem
  • Chapter 5 (on page 67) describes how to manage a 1094ARC NetLink modem
  • Chapter 6 (on page 89) describes how to manage a 1095RC NetLink modem
  • Chapter 7 (on page 129) describes how to manage a 2701RC NetLink modem
  • Chapter 8 (on page 167) describes how to manage a 2707RC NetLink modem
  • Chapter 9 (on page 187) describes how to manage a 3088RC G.SHDSL NTU rack card
  • Chapter 10 (on page 220) is the 1001MC-NMS HTTP/HTML web page reference
  • Chapter 11 (on page 276) contains troubleshooting and maintenance information
  • Chapter 12 (on page 286) contains information on contacting Patton technical support for assistance
Page 7 of the Patton electronic 1001MC user manual — Typographical conventions used in this document
Page 7 · click to enlarge
Page 7

Model 1001MC Operations Guide

Typographical conventions used in this document

This section describes the typographical conventions and terms used in this guide.

The procedures described in this manual use the following text conventions:

Table 1. Text conventions

ConventionMeaning Garamond blue typeIndicates a cross-reference hyperlink that points to a figure, graphic, table, or section heading. Clicking on the hyperlink jumps you to the reference. When you have finished reviewing the reference, click on the Go to Previous View button in the Adobe® Acrobat® Reader toolbar to return to your starting point. Futura bold typeIndicates the names of menu bar options. Italicized Futura typeIndicates the names of options on pull-down menus. Futura typeIndicates the names of fields or windows. Garamond bold typeIndicates the names of command buttons that execute an action. < >Angle brackets indicate function and keyboard keys, such as <SHIFT>, <CTRL>, <C>, and so on. Are you ready?All system messages and prompts appear in the Courier font as the system would display them. % dir *.*Bold Courier font indicates where the operator must type a response or command

About this guide · General conventions

Page 8 of the Patton electronic 1001MC user manual — Technical support
Page 8 · click to enlarge
Page 8

Model 1001MC Operations Guide

The following conventions are used when describing mouse actions:

Table 2. Mouse conventions

ConventionMeaning Left mouse buttonThis button refers to the primary or leftmost mouse button (unless you have changed the default configuration). Right mouse buttonThis button refers the secondary or rightmost mouse button (unless you have changed the default configuration) PointThis word means to move the mouse in such a way that the tip of the pointing arrow on the screen ends up resting at the desired location. ClickMeans to quickly press and release the left or right mouse button (as instructed in the procedure). Make sure you do not move the mouse pointer while clicking a mouse button. Double-click means to press and release the same mouse button two times quickly DragThis word means to point the arrow and then hold down the left or right mouse button (as instructed in the procedure) as you move the mouse to a new location. When you have moved the mouse pointer to the desired location, you can release the mouse button.

Additional References

The Patton Electronics website (www.patton.com) provides 1001MC and NetLink modem application notes, which includes FAQ, startup notes, and test setups.

Use a web browser to find online copies of the following requests for comments (RFC) documents:

  • RFC 1643,

Definitions of Managed Objects for the Ethernet-like Interface Types

  • RFC 1155,

Structure and Identification of Management Information for TCP/IP-based Internets

  • RFC 1213,

Management Information Base for Network Management of TCP/IP-based Internets: MIB-II

  • RFC 1389,

RIP Version 2 MIB Extension

  • RFC 1643,

Definitions of Managed Objects for the Ethernet-like Interface Types

Technical support

Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.

  • Online support—available at

www.patton.com

  • E-mail support—e-mail sent to

support@patton.com

will be answered within 1 business day

  • Telephone support—standard telephone support is available Monday through Friday, from 8:00 A.M. to 5:00 P.M. EST (8:00 to 17:00 UTC-5), Monday through Friday by calling
Show 5 more labels / short text on this page
About this guide · Mouse conventions · RFCs · +1 (301) 975-1007 · Additional References
Page 9 of the Patton electronic 1001MC user manual — Service
Page 9 · click to enlarge
Page 9

Model 1001MC Operations Guide

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Services at:

  • Tel:
  • E-mail:

support@patton.com

  • URL:

http://www.patton.com

Packages received without an RMA number will not be accepted.

Show 5 more labels / short text on this page
About this guide · Service · +1 · (301) 975-1007 · Technical support
Page 10 of the Patton electronic 1001MC user manual — Chapter 1
Page 10 · click to enlarge
Page 10

Chapter 1

Introduction

Introduction 11 Model 1001MC management overview 14

Chapter contents

Page 11 of the Patton electronic 1001MC user manual — Introduction
Page 11 · click to enlarge
Page 11

Model 1001MC Operations Guide

Introduction

The Model 1001MC NetLink™ SNMP Management Card (see figure 1) enables an SNMP workstation to configure and monitor multiple Patton NetLink cards racks and their connected standalone units.

Patton electronic 1001MC — Introduction diagram (page 11)
Fig. 2 · Introduction

Figure 1. Model 1001MC NetLink Management Card

The management card has the following features:

  • Connects to the SNMP workstation via a 10Base-T Ethernet (RJ-45) connection
  • Uses a standard web browser (Internet Explorer or Netscape Navigator, for example) to configure the HTTP/HTML management screens.
  • Supports generic network management software and MIB walking tools
  • Functions as an SNMP proxy agent for Patton NetLink rack cards and their remote standalone units
  • FLASH upgradeable through FTP connection
  • User selectable traps on a per-card basis
  • Compatible with the following rack cards:

- Model 1092ARC KiloModem™ 2 or 4-wire Baseband Modem with 2B1Q Encoding

- Model 1094ARC NetLink 1.152-Mbps HDSL Modem

- Model 1095RC NetLink 2-wire, 2-Mbps mDSL Modem

- Model 2701RC G.703/G.704 Network Termination Unit (NTU)

- Model 2707RC G.703 NTU

- Model 2710RC T1/FT1 CSU/DSU

- Model 2715RC G.703/G.704 NTU

1 • Introduction · Introduction

Page 12 of the Patton electronic 1001MC user manual — Introduction
Page 12 · click to enlarge
Page 12

Model 1001MC Operations Guide

- Model 3088RC G.SHDSL V.35 - M34

- Model 3088RC G.SHDSL X.21 - DB15

- Model 3088RC G.SHDSL E1 - Dual BNC & RJ-45

- Model 3088RC G.SHDSL Ethernet BR - RJ-45

Your specific model of 1001MC may not support all of the models listed above.

The 1001MC front and rear cards (see figure 2) install into the Model 1001R14/16 NetLink Rack Chassis (see figure 3). The rack chassis accepts up to 15 cards and a 90–264 VAC or -12/-24/-48 VDC power supply module (redundant power supply configurations can be created by replacing two rack cards with a second power supply).

Patton electronic 1001MC — Introduction diagram (page 12)
Fig. 3 · Introduction

Figure 2. Model 1001MC front and rear cards

1 • Introduction · Introduction

Page 13 of the Patton electronic 1001MC user manual — Introduction
Page 13 · click to enlarge
Page 13

Model 1001MC Operations Guide

Patton electronic 1001MC — Introduction diagram (page 13)
Fig. 4 · Introduction

Figure 3. Model 1001R14/16 Rack Chassis with power supply

1 • Introduction · Introduction

Page 14 of the Patton electronic 1001MC user manual — Model 1001MC management overview
Page 14 · click to enlarge
Page 14

Model 1001MC Operations Guide

Model 1001MC management overview

The Model 1001MC uses a 10Base-T Ethernet port to connect to a local LAN (or to any location in the world via the Internet). Management can be performed using any SNMP station or web browser with the internal HTTP/HTML management screens. As shown in figure 4, the Model 1001MC can manage multiple racks of Patton NetLink modems using a daisy-chain configuration and a 1001CC in each additionally managed rack.

Patton electronic 1001MC — Model 1001MC management overview diagram (page 14)
Fig. 5 · Model 1001MC management overview

Figure 4. Network management through a network using a 10Base-T connection to Model 1001MC

Model 1001MC management overview

1 • Introduction

Page 15 of the Patton electronic 1001MC user manual — Table of contents
Page 15 · click to enlarge
Page 15

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 16 of the Patton electronic 1001MC user manual — Table of contents
Page 16 · click to enlarge
Page 16

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 17 of the Patton electronic 1001MC user manual — Introduction
Page 17 · click to enlarge
Page 17

Model 1001MC Operations Guide 2 • Hardware installation

Introduction

Model 1001MC installation consists of the following:

  • Installing the front and rear cards into the rack chassis (see section “Installing the Model 1001MC into the rack chassis” on page 18)
  • Configuring and installing the NetLink modem cards (see section “Installing NetLink modem cards” on page 19)
  • Installing the NetLink power supply (or supplies) (see section “Installing the power supplies” on page 31)
  • Verifying that the 1001MC functions normally when power is applied (see section “Verifying 1001MC functioning” on page 31)
  • Installing the interface cables (see section “Connecting the cables” on page 32)

When you finish installing the 1001MC, go to chapter 3, “Getting started” on page 36.

Before you install… Before installing and configuring your Model 1001MC, make sure you have the following items at hand:

  • A VT100 terminal or a VT100 terminal emulator for connection to the RS-232 configuration port
  • A null modem or a null modem cable to connect your VT100 terminal to the Model 1001MC
  • An Ethernet connection to your local LAN
  • A locally connected workstation (e.g. PC) that you can use to ping the 1001MC
  • An IP address for the Model 1001MC
  • The network address space and netmask
  • The IP address for the default gateway of your LAN

Checking the contents… Verify that the shipping container holds the following items:

  • 1001MC front and rear cards
  • 1001MC CD-ROM that includes this manual

Introduction 17

Page 18 of the Patton electronic 1001MC user manual — Installing the Model 1001MC into the rack chassis
Page 18 · click to enlarge
Page 18

Model 1001MC Operations Guide 2 • Hardware installation

Patton electronic 1001MC — Installing the Model 1001MC into the rack chassis diagram (page 18)
Fig. 6 · Installing the Model 1001MC into the rack chassis

Figure 5. Rack chassis slot layout (rear view)

Installing the Model 1001MC into the rack chassis

The Model 1001MC consists of a front rack card and a rear input/output (I/O) card (see figure 2 on page 12). The two cards meet inside the rack chassis and plug into each other by way of mating 50-pin card edge connec- tors. Do the following to install the Model 1001MC cards into the rack chassis:

Patton electronic 1001MC — Installing the Model 1001MC into the rack chassis diagram (page 18)
Fig. 7 · Installing the Model 1001MC into the rack chassis

There are no user-serviceable parts in the power supply section. Voltage set- ting changes and fuse replacement should only be performed by qualified ser- vice personnel. Contact Patton Electronics Technical support at (301) 975-1007 for more information.

1. Slide the rear I/O card into rear chassis slot 14 (see figure 5 ) along the metal guide rails.
2. Secure the rear card using the captive fasteners.

Installing the Model 1001MC into the rack chassis 18

Page 19 of the Patton electronic 1001MC user manual — Installing NetLink modem cards
Page 19 · click to enlarge
Page 19

Model 1001MC Operations Guide 2 • Hardware installation

3. Slide the front rack card into the front chassis slot 14 (see figure 6 ) until it meets the rear card receptacle. When that happens, push the front card gently but firmly into the card-edge receptacle of the rear card, it should click into place.
Patton electronic 1001MC — Installing NetLink modem cards diagram (page 19)
Fig. 8 · Installing NetLink modem cards

Figure 6. Rack chassis slot layout (front view)

4. Secure the front rack card using the captive fasteners.

Installing NetLink modem cards

This section contains hardware installation information that affects the following NetLink modems:

  • Model 1092ARC (see section “Hardware setup for a Model 1092ARC” )
  • Model 1094ARC (see section “Hardware setup for a Model 1094ARC” on page 22)
  • Model 1095RC (see section “Hardware setup for a Model 1095RC” on page 24)
  • Model 2701RC (see section “Hardware setup for a Model 2701RC” on page 26)
  • Model 2707RC (see section “Hardware setup for a Model 2707RC” on page 28)
  • Model 2710RC (see section “Hardware setup for a Model 2710RC” on page 29)
  • Model 2715RC (see section “Hardware setup for a Model 2715RC” on page 29)
  • Model 2088RC (see section “Hardware setup for a Model 3088RC” on page 29)

Hardware setup for a Model 1092ARC The following must be done to configure your Model 1092ARC hardware for use with the Model 1001MC network management station:

  • Connect frame ground to signal ground (see section “Configuring frame ground” )
  • Set the system address (see section “Setting the 1092ARC system address” on page 20)

When you are finished, install the Model 1092ARC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.

Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 1092ARC rear I/O card must have frame ground (GND) connected to signal GND through a

Installing NetLink modem cards 19

Page 20 of the Patton electronic 1001MC user manual — Setting the 1092ARC system address
Page 20 · click to enlarge
Page 20

Model 1001MC Operations Guide 2 • Hardware installation

100-ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.

Setting the 1092ARC system address The manual that was shipped with the 1092ARC defines switch S2 as Address. This switch sets the address of the modem in the NetLink system. Each card in the chassis is given a unique address through the setting of switch S2.

Polling overview. The Model 1001MC sends poll messages along the internal bus looking for cards installed in the system. Once a card is found it is placed online and communication with the management station can begin.

If the address of the NetLink modem is not configured or does not match the address range of the rack that it is installed in, the Model 1001MC may not recognize the card. The address range that is polled is determined by the configuration of the system. The system administrator must make sure that the software configuration within the Model 1001MC matches the hardware configuration of the system.

Polling rack #1 and daisy-chained racks. The Model 1001MC uses the number of power supplies in the sys- tem to determine what the address range of the individual racks will be. The number of power supplies installed in each rack is entered on the Modem Information page. If the system is set for two power supplies installed, the 1001MC will automatically set the number of slots available (displayed on the Modem Informa- tion page) in the chassis to 13. If the system is set for a single power supply installed, the 1001MC will auto- matically set the number of slots available in the chassis to 15.

Using this information, the Model 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15

The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. In a redundant power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 14.

The daisy chained racks are set up in the same manner with 13 addresses being available in a redundant system and 15 addresses being available in single supply system. When you disable a rack the addresses are still set aside for that rack space. If a power supply is removed, the addressing will not change unless you make the change through the 1001MC web pages. This allows easy service of the power supplies.

If the address is 0 (all ON position), then the unit will run completely from its DIP-switch configuration. This can be useful for testing circuits independently of the management system. If an address is placed on the switch, the unit will boot from its stored flash configuration and begin looking for poll commands from the Model 1001MC.

Switch S2 allows an 8 bit address to be assigned to a link. The following rules apply to setting the address. Bit S2-8 is the least significant bit. A bit set to ON is considered a 0. A bit set to OFF is considered a 1. Patton Electronics suggests that you set your addresses starting with address 1 at the far left of your rack (farthest away

Installing NetLink modem cards 20

Page 21 of the Patton electronic 1001MC user manual — Setting the 1092ARC system address
Page 21 · click to enlarge
Page 21

Model 1001MC Operations Guide 2 • Hardware installation

from the power supplies) and increment the numbers by one as you go from left to right. Setting the addresses in this manner will make configuration easier as you start using the web page management. An example of this is shown below.

1. 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - NMS - PS2 - PS1

Table 3 shows the bit setting to configure the address. Table 4 shows examples of address settings.

Table 3. Bit setting to configure the address

Patton electronic 1001MC — Setting the 1092ARC system address diagram (page 21)
Fig. 9 · Setting the 1092ARC system address

0 ON 1 ON ON ON OFF 2 ON ON OFF ON 3 ON ON OFF OFF 4 ON OFF ON ON 5 ON OFF ON OFF 6 ON OFF OFF ON 7 ON OFF OFF ON 8 OFF ON ON ON 9 OFF ON ON OFF A OFF ON OFF ON B OFF ON OFF OFF C OFF OFF ON ON D OFF OFF ON OFF E OFF OFF OFF ON F OFF

Address in Hex (Dec.) S2-7 S2-6 S2-5 S2-4 S2-3 S2-2 S2-1

0x01 (1) ON OFF 0x02 (2) ON OFF ON 0x10 (16) ON ON OFF ON 0x35 (53) ON OFF OFF ON OFF ON OFF

Installing NetLink modem cards 21

Page 22 of the Patton electronic 1001MC user manual — Hardware setup for a Model 1094ARC
Page 22 · click to enlarge
Page 22

Model 1001MC Operations Guide 2 • Hardware installation

Hardware setup for a Model 1094ARC The following must be done to configure your Model 1094ARC hardware for use with the Model 1001MC network management station:

  • Connect frame ground to signal ground (see section “Configuring frame ground” )
  • Set the system address (see section “Setting the 1094ARC system address” )

When you are finished, install the Model 1094ARC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.

Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 1094ARC rear I/O card must have frame ground (GND) connected to signal GND through a 100-ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.

Setting the 1094ARC system address The manual that was shipped with the 1094RC defines switch S1 as Address. This switch sets the address of the modem in the NetLink system. Each card in the chassis is given a unique address through the setting of switch S1.

Polling overview. The Model 1001MC sends poll messages along the internal bus looking for cards installed in the system. Once a card is found it is placed online and communication with the management station can begin.

If the address of the NetLink modem is not configured or does not match the address range of the rack that it is installed in, the Model 1001MC may not recognize the card. The address range that is polled is determined by the configuration of the system. The system administrator must make sure that the software configuration within the Model 1001MC matches the hardware configuration of the system.

Polling rack #1 and daisy-chained racks. The Model 1001MC uses the number of power supplies in the sys- tem to determine what the address range of the individual racks will be. The number of power supplies installed in each rack is entered on the Modem Information page. If the system is set for two power supplies installed, the 1001MC will automatically set the number of slots available (displayed on the Modem Informa- tion page) in the chassis to 13. If the system is set for a single power supply installed, the 1001MC will auto- matically set the number of slots available in the chassis to 15.

Using this information, the Model 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15

The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. In a redundant power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from

Installing NetLink modem cards 22

Page 23 of the Patton electronic 1001MC user manual — S1-2 (S1-6)
Page 23 · click to enlarge
Page 23

Model 1001MC Operations Guide 2 • Hardware installation

address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 14.

The daisy chained racks are set up in the same manner with 13 addresses being available in a redundant system and 15 addresses being available in single supply system. When you disable a rack the addresses are still set aside for that rack space. If a power supply is removed, the addressing will not change unless you make the change through the 1001MC web pages. This allows easy service of the power supplies.

If the address is 0 (all ON position), then the unit will run completely from its DIP-switch configuration. This can be useful for testing circuits independently of the management system. If an address is placed on the switch, the unit will boot from its stored flash configuration and begin looking for poll commands from the Model 1001MC.

Switch S1 allows an 8 bit address to be assigned to a link. The following rules apply to setting the address. Bit S1-8 is the least significant bit. A bit set to ON is considered a 0. A bit set to OFF is considered a 1. Patton Electronics suggests that you set your addresses starting with address 1 at the far left of your rack (farthest away from the power supplies) and increment the numbers by one as you go from left to right. Setting the addresses in this manner will make configuration easier as you start using the web page management. An example of this is shown below.

1. 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - NMS - PS2 - PS1

Table 5 shows the bit setting to configure the address. Table 6 shows examples of address settings.

Table 5. Bit setting to configure the address

Upper (Lower) Nibble S1-1 (S1-5)

S1-2 (S1-6)

S1-3 (S1-7)

S1-4 (S1-8)

0 ON 1 ON ON ON OFF 2 ON ON OFF ON 3 ON ON OFF OFF 4 ON OFF ON ON 5 ON OFF ON OFF

6 ON OFF OFF ON 7 ON OFF OFF ON 8 OFF ON ON ON 9 OFF ON ON OFF A OFF ON OFF ON B OFF ON OFF OFF C OFF OFF ON ON D OFF OFF ON OFF E OFF OFF OFF ON F OFF

Installing NetLink modem cards 23

Page 24 of the Patton electronic 1001MC user manual — Hardware setup for a Model 1095RC
Page 24 · click to enlarge
Page 24

Model 1001MC Operations Guide 2 • Hardware installation

Table 6. Examples of address settings

Address in Hex (Dec.) S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 S1-8

0x01 (1) ON OFF 0x02 (2) ON OFF ON 0x10(16) ON ON ON OFF ON 0xB5(181) OFF ON OFF OFF ON OFF ON OFF

Hardware setup for a Model 1095RC The following must be done to configure your Model 1095RC hardware for use with the Model 1001MC net- work management station:

  • Connect frame ground to signal ground (see section “Configuring frame ground” )
  • Set the system address (see section “Setting the 1094ARC system address” )

When you are finished, install the Model 1095RC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.

Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 1095RC rear I/O card must have frame ground (GND) connected to signal GND through a 100- ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.

Setting the 1095RC system address The manual that was shipped with the 1095RC defines switch S1 as Address. This switch sets the address of the modem in the NetLink system. Each card in the chassis is given a unique address through the setting of switch S1.

Polling overview. The Model 1001MC sends poll messages along the internal bus looking for cards installed in the system. Once a card is found it is placed online and communication with the management station can begin.

If the address of the NetLink modem is not configured or does not match the address range of the rack that it is installed in, the Model 1001MC may not recognize the card. The address range that is polled is determined by the configuration of the system. The system administrator must make sure that the software configuration within the Model 1001MC matches the hardware configuration of the system.

Polling rack #1 and daisy-chained racks. The Model 1001MC uses the number of power supplies in the sys- tem to determine what the address range of the individual racks will be. The number of power supplies installed in each rack is entered on the Modem Information page. If the system is set for two power supplies installed, the 1001MC will automatically set the number of slots available (displayed on the Modem Informa- tion page) in the chassis to 13. If the system is set for a single power supply installed, the 1001MC will auto- matically set the number of slots available in the chassis to 15.

Installing NetLink modem cards 24

Page 25 of the Patton electronic 1001MC user manual — Hardware setup for a Model 1095RC
Page 25 · click to enlarge
Page 25

Model 1001MC Operations Guide 2 • Hardware installation

Using this information, the Model 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15

The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. In a redundant power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 14.

The daisy chained racks are set up in the same manner with 13 addresses being available in a redundant system and 15 addresses being available in single supply system. When you disable a rack the addresses are still set aside for that rack space. If a power supply is removed, the addressing will not change unless you make the change through the 1001MC web pages. This allows easy service of the power supplies.

If the address is 0 (all ON position), then the unit will run completely from its DIP-switch configuration. This can be useful for testing circuits independently of the management system. If an address is placed on the switch, the unit will boot from its stored flash configuration and begin looking for poll commands from the Model 1001MC.

Switch S1 allows an 8 bit address to be assigned to a link. The following rules apply to setting the address. Bit S1-8 is the least significant bit. A bit set to ON is considered a 0. A bit set to OFF is considered a 1. Patton Electronics suggests that you set your addresses starting with address 1 at the far left of your rack (farthest away from the power supplies) and increment the numbers by one as you go from left to right. Setting the addresses in this manner will make configuration easier as you start using the web page management. An example of this is shown below.

1. 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - NMS - PS2 - PS1

Installing NetLink modem cards 25

Page 26 of the Patton electronic 1001MC user manual — Hardware setup for a Model 2701RC
Page 26 · click to enlarge
Page 26

Model 1001MC Operations Guide 2 • Hardware installation

Table 7 shows the bit setting to configure the address. Table 8 shows examples of address settings.

Table 7. Bit setting to configure the address

Patton electronic 1001MC — Hardware setup for a Model 2701RC diagram (page 26)
Fig. 10 · Hardware setup for a Model 2701RC

0 ON 1 ON ON ON OFF 2 ON ON OFF ON 3 ON ON OFF OFF 4 ON OFF ON ON 5 ON OFF ON OFF 6 ON OFF OFF ON 7 ON OFF OFF ON 8 OFF ON ON ON 9 OFF ON ON OFF A OFF ON OFF ON B OFF ON OFF OFF C OFF OFF ON ON D OFF OFF ON OFF E OFF OFF OFF ON F OFF

Address in Hex (Dec.) S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 S1-8

0x01 (1) ON OFF 0x02 (2) ON OFF ON 0x10(16) ON ON ON OFF ON 0xB5(181) OFF ON OFF OFF ON OFF ON OFF

Hardware setup for a Model 2701RC The following must be done to configure your Model 2701RC hardware for use with the Model 1001MC net- work management station:

  • Connect frame ground to signal ground (see section “Configuring frame ground” )
  • Set the system address (see section “Setting the 2701RC system address” )

When you are finished, install the Model 2701RC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.

Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 2701RC rear I/O card must have frame ground (GND) connected to signal GND through a 100- ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.

Installing NetLink modem cards 26

Page 27 of the Patton electronic 1001MC user manual — Setting the 2701RC system address
Page 27 · click to enlarge
Page 27

Model 1001MC Operations Guide 2 • Hardware installation

Setting the 2701RC system address The manual that was shipped with your NetLink-E1 unit specifies switch S3 for the card address in the NetLink System. Each card in the chassis is given a unique address through the setting of switch S3.

Polling overview. The Model 1001MC sends “poll” messages along the internal bus looking for cards installed in the system. Once a card is found it is placed “online” and communication with the management station can begin.

If the address of the NetLink modem is not configured or does not match the address range of the rack that it is installed in, the Model 1001MC may not recognize the card. The address range that is polled is determined by the configuration of the system. The system administrator must make sure that the software configuration within the Model 1001MC matches the hardware configuration of the system.

Polling rack #1 and daisy-chained racks. The Model 1001MC uses the number of power supplies in the sys- tem to determine what the address range of the individual racks will be. The number of power supplies installed in each rack is entered on the Modem Information page. If the system is set for two power supplies installed, the 1001MC will automatically set the number of slots available (displayed on the Modem Informa- tion page) in the chassis to 13. If the system is set for a single power supply installed, the 1001MC will auto- matically set the number of slots available in the chassis to 15.

Using this information, the Model 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15

The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. In a redundant power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 14.

The daisy chained racks are set up in the same manner with 13 addresses being available in a redundant system and 15 addresses being available in single supply system. When you disable a rack the addresses are still set aside for that rack space. If a power supply is removed, the addressing will not change unless you make the change through the 1001MC web pages. This allows easy service of the power supplies.

The 2701RCs are shipped to use DIP switch configuration as default. Software configuration can be enabled through either the VT-100 screens or through the 1001MC NMS. To use the NMS, switch S2-7 must be set to the “OFF” position, otherwise the VT-100 port is active.

Switch S3 allows a decimal address to be assigned to a link. The following rules apply to setting the address:

  • S3-1 is the LSB and S3-8 is the MSB
  • Patton Electronics suggests that you set your addresses starting with address 1 at the far left of your rack (farthest away from the power supplies) and increment the numbers by one as you go from left to right. Setting the addresses in this manner will make configuration easier as you start using the web page management. An example of this is below.

Installing NetLink modem cards 27

Page 28 of the Patton electronic 1001MC user manual — Hardware setup for a Model 2707RC
Page 28 · click to enlarge
Page 28

Model 1001MC Operations Guide 2 • Hardware installation

1. 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - NMS - PS2 - PS1

Figure 7 shows the bit setting to configure the address. Table 9 shows examples of address settings.

Patton electronic 1001MC — Hardware setup for a Model 2707RC diagram (page 28)
Fig. 11 · Hardware setup for a Model 2707RC

Figure 7. Bit setting to configure the address

Table 9. Examples of address settings

Patton electronic 1001MC — Hardware setup for a Model 2707RC diagram (page 28)
Fig. 12 · Hardware setup for a Model 2707RC

Hex Address (Decimal Address) S3-8 S3-7 S3-6 S3-5 S3-4 S3-3 S3-2 S3-1

0x01 (1) ON OFF 0x02 (2) ON OFF ON 0x10(16) ON ON ON OFF ON 0xB5(181) OFF ON OFF OFF ON OFF ON OFF

Hardware setup for a Model 2707RC The following must be done to configure your Model 2707RC hardware for use with the Model 1001MC net- work management station:

  • Connect frame ground to signal ground (see section “Configuring frame ground” )

When you are finished, install the Model 2707RC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.

Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 2707RC rear I/O card must have frame ground (GND) connected to signal GND through a 100- ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.

Installing NetLink modem cards 28

Page 29 of the Patton electronic 1001MC user manual — Hardware setup for a Model 2710RC
Page 29 · click to enlarge
Page 29

Model 1001MC Operations Guide 2 • Hardware installation

Hardware setup for a Model 2710RC The following must be done to configure your Model 2710RC hardware for use with the Model 1001MC net- work management station:

  • Connect frame ground to signal ground (see section “Configuring frame ground” )

When you are finished, install the Model 2710RC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.

Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 2710RC rear I/O card must have frame ground (GND) connected to signal GND through a 100- ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.

Hardware setup for a Model 2715RC The following must be done to configure your Model 2715RC hardware for use with the Model 1001MC net- work management station:

  • Connect frame ground to signal ground (see section “Configuring frame ground” )

When you are finished, install the Model 2715RC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.

Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 2715RC rear I/O card must have frame ground (GND) connected to signal GND through a 100- ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.

Hardware setup for a Model 3088RC The following must be done to configure your Model 3088RC hardware for use with the Model 1001MC net- work management station:

  • Connect frame ground to signal ground (see section “Configuring frame ground” )
  • Set the system address (see section “Setting the 2701RC system address” )

When you are finished, install the Model 3088RC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.

Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 3088RC rear I/O card must have frame ground (GND) connected to signal GND through a 100- ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.

Setting the 3088RC system address The manual that was shipped with your NetLink-E1 unit specifies switch S3 for the card address in the NetLink System. Each card in the chassis is given a unique address through the setting of switch S3.

Installing NetLink modem cards 29

Page 30 of the Patton electronic 1001MC user manual — Hardware setup for a Model 2710RC
Page 30 · click to enlarge
Page 30

Model 1001MC Operations Guide 2 • Hardware installation

Polling overview. The Model 1001MC sends “poll” messages along the internal bus looking for cards installed in the system. Once a card is found it is placed “online” and communication with the management station can begin.

If the address of the NetLink modem is not configured or does not match the address range of the rack that it is installed in, the Model 1001MC may not recognize the card. The address range that is polled is determined by the configuration of the system. The system administrator must make sure that the software configuration within the Model 1001MC matches the hardware configuration of the system.

Polling rack #1 and daisy-chained racks. The Model 1001MC uses the number of power supplies in the sys- tem to determine what the address range of the individual racks will be. The number of power supplies installed in each rack is entered on the Modem Information page. If the system is set for two power supplies installed, the 1001MC will automatically set the number of slots available (displayed on the Modem Informa- tion page) in the chassis to 13. If the system is set for a single power supply installed, the 1001MC will auto- matically set the number of slots available in the chassis to 15.

Using this information, the Model 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15

The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. In a redundant power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 14.

The daisy chained racks are set up in the same manner with 13 addresses being available in a redundant system and 15 addresses being available in single supply system. When you disable a rack the addresses are still set aside for that rack space. If a power supply is removed, the addressing will not change unless you make the change through the 1001MC web pages. This allows easy service of the power supplies.

Switch S3 allows a decimal address to be assigned to a link. The following rules apply to setting the address:

  • S3-1 is the LSB and S3-8 is the MSB
  • Patton Electronics suggests that you set your addresses starting with address 1 at the far left of your rack (farthest away from the power supplies) and increment the numbers by one as you go from left to right. Setting the addresses in this manner will make configuration easier as you start using the web page management. An example of this is below.
1. 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - NMS - PS2 - PS1

Installing NetLink modem cards 30

Page 31 of the Patton electronic 1001MC user manual — Verifying 1001MC functioning
Page 31 · click to enlarge
Page 31

Model 1001MC Operations Guide 2 • Hardware installation

Figure 7 shows the bit setting to configure the address. Table 9 shows examples of address settings.

Patton electronic 1001MC — Installing the power supplies diagram (page 31)
Fig. 13 · Installing the power supplies

Figure 8. Bit setting to configure the address

Table 10. Examples of address settings

Patton electronic 1001MC — Installing the power supplies diagram (page 31)
Fig. 14 · Installing the power supplies

Hex Address (Decimal Address) S3-8 S3-7 S3-6 S3-5 S3-4 S3-3 S3-2 S3-1

0x01 (1) ON OFF 0x02 (2) ON OFF ON 0x10(16) ON ON ON OFF ON 0xB5(181) OFF ON OFF OFF ON OFF ON OFF

Installing the power supplies

Refer to the installation manual that came with the power supply (or supplies) to install the supply and rear power entry module into the rack chassis.

Verifying 1001MC functioning

1. Apply power to the rack system, verify that the green Power LED on the Model 1001MC front card illuminates.
2. Turn off power to the rack system, verify that the green Power LED on the Model 1001MC front card extinguishes.

Installing the power supplies 31

Page 32 of the Patton electronic 1001MC user manual — Connecting the cables
Page 32 · click to enlarge
Page 32

Model 1001MC Operations Guide 2 • Hardware installation

Connecting the cables

Installing 1001MC rear I/O card cables takes place in the following order:

Patton electronic 1001MC — Connecting the cables diagram (page 32)
Fig. 15 · Connecting the cables

Do not work on the system or connect or disconnect cables during periods of lightning activity.

1. Installing the 10Base-T Ethernet cable onto the 10Base-T port (see figure 9 ) (see “Installing the Ethernet cable” on page 32).
2. Installing the cable onto the RS-232 configuration/daisy-chain port (see figure 9 ) (see “Installing the RS232 configuration/daisy-chain port cable” on page 34).
Patton electronic 1001MC — Connecting the cables diagram (page 32)
Fig. 16 · Connecting the cables

Figure 9. Rear I/O card ports

Installing the Ethernet cable The RJ-45 Ethernet jack on the rear I/O card of the Model 1001MC is designed to connect directly to a 10Base-T network. Figure 10 shows the RJ-45 jack pin-out diagram. Refer to the following sections when con- structing Ethernet cables to connect to the Patton Model 1001MC.

Patton electronic 1001MC — Connecting the cables diagram (page 32)
Fig. 17 · Connecting the cables

Figure 10. 1001MC 10Base-T Ethernet port pin-out diagram

Connecting the cables 32

Page 33 of the Patton electronic 1001MC user manual — Connecting a 10Base-T hub to the 1001MC
Page 33 · click to enlarge
Page 33

Model 1001MC Operations Guide 2 • Hardware installation

Connecting a 10Base-T hub to the 1001MC The Ethernet 10Base-T port on the rear of the 1001MC connects directly to a 10Base-T hub or repeater using RJ-45 unshielded twisted-pair cable that is wired straight-through (see figure 11).

Patton electronic 1001MC — Connecting a 10Base-T hub to the 1001MC diagram (page 33)
Fig. 18 · Connecting a 10Base-T hub to the 1001MC

Figure 11. Hub wiring diagram

Connecting a 10Base-T workstation to the 1001MC The 10Base-T port on the 1001MC connected to a workstation by means of a cross-connect cable. Refer to figure 12 to build a cross-connect cable that connects between the 10Base-T port on a workstation’s NIC and the 1001MC’s 10Base-T port.

Patton electronic 1001MC — Connecting a 10Base-T hub to the 1001MC diagram (page 33)
Fig. 19 · Connecting a 10Base-T hub to the 1001MC

Figure 12. Workstation wiring diagram

Connecting the cables 33

Page 34 of the Patton electronic 1001MC user manual — LED indicators
Page 34 · click to enlarge
Page 34

Model 1001MC Operations Guide 2 • Hardware installation

Installing the RS-232 configuration/daisy-chain port cable The DB-25 connector is a DTE-configured RS-232 port that is used to set up your IP address, subnet mask, and default configuration. After the system is set up, the configuration port can be used to connect to a Model 1001CC in a separate rack if you are daisy-chaining multiple racks.

Patton electronic 1001MC — Installing the RS-232 configuration/daisy-chain port cable diagram (page 34)
Fig. 20 · Installing the RS-232 configuration/daisy-chain port…

Figure 13. RS-232 DTE configuration port

Using personal computer communications software (Procomm, Windows Terminal, BitCom, PC Anywhere, etc.), set the configuration of your communications software to the following parameters:

  • Data Rate : 19,200 bps
  • Async. Character Format : 8 Data Bits, 1 Stop Bit, No Parity
  • Terminal Emulation : VT-100 (or similar) terminal emulation

LED indicators

The 1001MC front card has status LEDs (see figure 14) that display at-a-glance the current operational status of the 1001MC.

Patton electronic 1001MC — LED indicators diagram (page 34)
Fig. 21 · LED indicators

Figure 14. Front card LEDs

LED indicators 34

Page 35 of the Patton electronic 1001MC user manual — Where to go next
Page 35 · click to enlarge
Page 35

Model 1001MC Operations Guide 2 • Hardware installation

Ethernet LED indicators The Ethernet LEDs convey transmit and receive data activity as well as the status of the link (see table 11).

Table 11. Ethernet LED indicators

LED Color Function Description

LI Green Twisted pair link indication On = Connected to active LAN Off = Not connected to active LAN TD Yellow/Green Transmit data from 1001MC

Yellow = Idle condition Green = Toggles yellow/green with activity RD Yellow/Green Receive data at 1001MC from LAN Yellow = Idle condition

Green = Toggles yellow/green with activity

Power LED indicator The power LED shows the power status of the Model 1001MC (see table 12).

Table 12. Power LED indicator

LED Color Function Description

Power Green Power status On = Power is ON Off = Power is OFF

Table 13. Poll LED indicator

LED Color Function Description

Poll Yellow Heartbeat Toggles when packet TX is on the backplane bus

Table 14. Fault LED indicator

LED Color Function Description

Fault Red Fault condition On = Signals hardware fault Off = No hardware fault

Where to go next

Congratulations, you have finished installing the Model 1001MC! Now go to chapter 3, “Getting started” on page 36.

Where to go next 35

Show 4 more labels / short text on this page
to LAN · Heartbeat LED indicator · Fault LED indicator · PPP LED indicator
Page 36 of the Patton electronic 1001MC user manual — Table of contents
Page 36 · click to enlarge
Page 36

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 37 of the Patton electronic 1001MC user manual — Booting the Model 1001MC
Page 37 · click to enlarge
Page 37

Model 1001MC Operations Guide 3 • Getting started

Introduction

To complete this section you will need the following:

  • a VT-100 terminal or terminal emulator
  • a null-modem cable
  • an IP address for your box
  • a subnet mask for your box
  • the IP address of the default gateway for your LAN

Booting the Model 1001MC

1. Using personal computer communications software (Procomm, Windows Terminal, BitCom, PC Anywhere, etc.), set the configuration of your communications software to the following parameters:
– Data rate19,200 bps
– Async. character format8 data bits, 1 stop bit, no parity
– Terminal emulationVT-100 (or similar) terminal emulation
2. Connect the RS-232/V.24 port of the terminal to the rear panel RS-232 configuration port of the 1001MC through a null-modem. The RS-232 port is configured as data terminal equipment (DTE).
3. Apply power to the rack system. The Model 1001MC will begin a series of diagnostic tests to exercise the internal sub-systems in the unit. You must halt the power up sequence in order to enter a new IP address, mask, and default gateway into the box. Press the b key three times when you see the following:

DRAM:Configure Complete

FLASH:Configure Complete

Boot Version May 11 1999 14:44:24

Valid operational code, Hit ‘b’ three times to stop operational boot

Validating operation code · Introduction 37

Page 38 of the Patton electronic 1001MC user manual — IP:209.49.110.188
Page 38 · click to enlarge
Page 38

Model 1001MC Operations Guide 3 • Getting started

5. After pressing the b key three times the system will display the following:

Timer Started May 11 1999 14:44:24

Address00.a0.ba.00.01.71

IP:192.168.200.1

Mask:255.255.255.0

Gateway:209.49.110.1

Change IP settings (y/n)?

4. Type Y to change the IP address. You will be prompted to enter a new IP address, mask, and default gateway as follows:

IP:209.49.110.188

Mask:255.255.255.0

Gateway:209.49.110.1

Change IP settings (y/n)? y

User Set IP:209.49.110.188

User Set Mask:255.255.255.0

User Set Gateway:209.49.110.1

IP:209.49.110.188

Mask:255.255.255.0

Gateway:209.49.110.1

Save these settings (y/n)? Y

5. After entering the information, the system will prompt you to save the IP settings. Type Y to save the new settings.
6. The Model 1001MC will prompt you for changes to the hardware revision that your unit requires as follows:

Current Hardware Revision B

Change Hardware Revision (y/n)? n

Booting the Model 1001MC 38

Show 8 more labels / short text on this page
Timer installed · Clock installed · Trying the console · ---Ethernet Hardware--- · ---Current IP settings--- · ---Current IP settings--- · ---Settings to save--- · ---Hardware Initialization---
Page 39 of the Patton electronic 1001MC user manual — Installing the Model 1001MC RS-232 daisy-chain port cable
Page 39 · click to enlarge
Page 39

Model 1001MC Operations Guide 3 • Getting started

Are you sure you want to erase current configuration (y/n)?y

If y is entered, the current configuration will be erased and the factory default configuration will be restored.

Are you sure you want to erase current configuration (y/n)?n

If n is entered, the boot sequence will continue without any changes to configuration.

7. Turn power off and on again reboot the system with the new settings. After your system reboots, log into the box using a standard web browser from your network.
8. Disconnect the cable from the rear panel RS-232 configuration port of the 1001MC.
9. If you are installing a daisy-chain cable to the RS-232 configuration port of the 1001MC, go to section “Installing the Model 1001MC RS-232 daisy-chain port cable” . Otherwise, go to section “Setting the address range for your NetLink modems” .

Installing the Model 1001MC RS-232 daisy-chain port cable

Using the Model 1001MC RS-232 Daisy Chain Port and an EIA-510 cable, your Model 1001MC can man- age up to seven additional racks. Each daisy chained rack must have a Model 1001CC Controller Card installed. The Model 1001MC—in combination with the Model 1001CC—can control up to 120 NetLink rack card modems and their remote CPE devices. This section describes how to connect your Model 1001MC to additional racks.

Installing the Model 1001MC RS-232 daisy-chain port cable 39

Page 40 of the Patton electronic 1001MC user manual — Setting the address range for your NetLink modems
Page 40 · click to enlarge
Page 40

Model 1001MC Operations Guide 3 • Getting started

Patton electronic 1001MC — Setting the address range for your NetLink modems diagram (page 40)
Fig. 22 · Setting the address range for your NetLink modems

Figure 15. Configuring a daisy-chain network

Setting the address range for your NetLink modems The Model 1001MC polls the system looking for NetLink modems. If the address of the NetLink modem is not configured or does not match the rack that it is installed in, the Model 1001MC may not find the card. The address range that is polled is determined by the configuration of the system. The system administrator must make sure that the software configuration within the Model 1001MC matches the hardware configura- tion of the system.

The Model 1001MC uses the number of power supplies in the system to determine what the address range of the individual racks will be. The number of power supplies installed in each rack is entered on the Modem Information page. If the system is set for two power supplies installed, the 1001MC will automatically set the number of slots available (displayed on the Modem Information page) in the chassis to 13. If the system is set for a single power supply installed, the 1001MC will automatically set the number of slots available in the chassis to 15.

Using this information, the Model 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15

Installing the Model 1001MC RS-232 daisy-chain port cable 40

Page 41 of the Patton electronic 1001MC user manual — Introduction to the internal HTTP/HTML management pages
Page 41 · click to enlarge
Page 41

Model 1001MC Operations Guide 3 • Getting started

The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. in a redundant power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 14.

The daisy-chained racks are setup in the same manner with 13 addresses being available in a redundant system and 15 addresses being available in single supply system. When you disable a rack the addresses are still set aside for that rack space. If a power supply is removed, the addressing will not change unless you make the change through the 1001MC web pages. This allows easy service of the power supplies.

Introduction to the internal HTTP/HTML management pages

This section explains how to configure the internal HTTP/HTML management pages to manage your Patton NetLink System. The system can also be managed by using an SNMP Network Management Station using a standard SNMP software package or MIB walking tool.

Logging into the HTTP/HTML administration pages To log into the HTTP/HTML administration pages, you must enter the 4-octet Internet protocol (IP) address—in the format http://your.server.ip.address (for example, http://201.168.15.12)—as the universal resource locator (URL) into a World-Wide Web (WWW) browser. After you enter the IP address, the 1001MC will prompt for your user name and password as shown in figure 16.

Patton electronic 1001MC — Introduction to the internal HTTP/HTML management pages diagram (page 41)
Fig. 23 · Introduction to the internal HTTP/HTML management pa…

Figure 16. 1001MC login window

The Model 1001MC has two levels of password protection:

  • superuser —The superuser password level lets you view statistics and make configuration changes to the system. To log in as a superuser, type the word superuser , all lower case, as the username and password
  • monitor —The monitor level password enables you to view statistics, but it will not let you make any configuration changes. To log into the system at the monitor level, type monitor , all lower case, for the username and password.

Introduction to the internal HTTP/HTML management pages 41

Page 42 of the Patton electronic 1001MC user manual — Saving HTTP/HTML object changes
Page 42 · click to enlarge
Page 42

Model 1001MC Operations Guide 3 • Getting started

HTTP/HTML and SNMP object format In this document, we shall describe the variables found on each of the internal HTTP/HTML pages. This description will include brief definitions of the Patton Enterprise MIB or SNMP MIB II object identifiers wherever applicable. The format of the variables will resemble figure 17.

Patton electronic 1001MC — HTTP/HTML and SNMP object format diagram (page 42)
Fig. 24 · HTTP/HTML and SNMP object format

Figure 17. HTTP/HTML and SNMP object format

Saving HTTP/HTML object changes

Sometimes you will need to save changes that you have made in the HTTP/HTML pages. Do the following to make changes to read/write variables:

1. Select the appropriate Modify screen.
2. Make changes to the desired parameter.
3. Click on the Submit button.
4. Return to the HOME screen.
5. Click on the Record Current Configuration button.

Help screens The Model 1001MC web pages have built-in help screens that enable you to get information about the vari- ables that are being described. Each web page contains several headings that describe the section that is being defined. Some of the headings are hyperlinks to the help screen for that page. The new window will automati- cally scroll to the help area that was requested. You may also scroll through this page to view help information about other sections of the page. In some cases, the headings for the tables will be shown as hyperlinks, these hyperlinks, work the same as was previously discussed, showing the help screen for that column of the table.

HTTP/HTML web page navigation This section describes how to navigate the internal HTTP/HTML web pages on the Model 1001MC. The diagram below shows how all of the web pages are linked together. Following figure 18, there is a brief descrip- tion of each page. For more detailed information about each web page, refer to chapter 10, “HTTP/HTML web page reference” on page 220.

Saving HTTP/HTML object changes 42

Page 43 of the Patton electronic 1001MC user manual — HTTP/HTML and SNMP object format
Page 43 · click to enlarge
Page 43

Model 1001MC Operations Guide 3 • Getting started

Patton electronic 1001MC — HTTP/HTML and SNMP object format diagram (page 43)
Fig. 25 · HTTP/HTML and SNMP object format

Figure 18. 1001MC command map

Saving HTTP/HTML object changes 43

Page 44 of the Patton electronic 1001MC user manual — Home
Page 44 · click to enlarge
Page 44

Model 1001MC Operations Guide 3 • Getting started

After logging in, the system displays the HOME page (see figure 19).

Patton electronic 1001MC — Home diagram (page 44)
Fig. 26 · Home

Figure 19. HOME page

Home The HOME page displays a quick overview of the system including; error and warning indications, software information, box names, number of modems installed, and so on.

On the left side of the HOME page is the Navigation View. The list on the left side of the screen allows you to navigate to any page from this point. The navigation page will always be available to you so you can change from one page to the next.

The Record Current Configuration button lets you store configuration changes made to the box.

The Hard Reset button forces the 1001MC to perform a reset. This will not reset the individual cards in the rack only the 1001MC. If you would like to perform a hardware reset on the individual cards, refer to the Slot Configuration page. For more information, refer to section “HOME” on page 228.

About 1001MC The About 1001MC page gives a more in-depth overview of the system that presented on the HOME page. This page also provides contact information about Patton Electronics. For more information, refer to section “About 1001MC” on page 231.

Saving HTTP/HTML object changes 44

Page 45 of the Patton electronic 1001MC user manual — Configure Cards
Page 45 · click to enlarge
Page 45

Model 1001MC Operations Guide 3 • Getting started

Configure Cards Clicking on the Configure Cards hyperlink displays the System Level Information page. This page is the starting point for the configuration and management of your Patton NetLink modems. This page enables you to quickly identify potential problems and view statistics on a per-rack basis. You can also disable racks from this level. For more information, refer to section “” on page 249.

The Download page enables you to perform software upgrades on the NetLink rack card modems installed in the system. New software for the modems can be obtained from Patton Electronics and uploaded into the 1001MC system via a file-transfer protocol (FTP) connection. For more information, refer to section “Down- load” on page 249.

System Log The System Log page displays Syslog messages. Syslog messaging is a reporting tool used in the Model 1001MC to log run-time operations. There are several levels of messages and you can set the system to report only messages above a certain level. For more information, refer to section “System Log” on page 251.

SNMP The SNMP web page enables you to download the Patton Enterprise MIBs for the Model 1001MC. These MIBs are required if you plan to manage the system using a network management station (NMS) instead of the web page manager. For more information, refer to section “SNMP” on page 258.

System Config The System Config web page is where Model 1095RC rack cards can be configured globally by templates you create. If you use this capability, you have the option to globally configure some or all Model 1095RC modems in multiple racks, or those in just one rack. For more information, refer to section “System Config” on page 259.

Help The Help Menu page provides hyperlinks to help pages located within the 1001MC. For more information, refer to section “Help” on page 275.

Saving HTTP/HTML object changes 45

Download

Page 46 of the Patton electronic 1001MC user manual — Where to go next…
Page 46 · click to enlarge
Page 46

Model 1001MC Operations Guide 3 • Getting started

Where to go next…

Refer to the following chapters as appropriate to manage the modem rack cards installed in your Model 1001 rack chassis:

  • Chapter 4, “Model 1092ARC management” on page 47
  • Chapter 5, “Model 1094ARC management” on page 67
  • Chapter 6, “Model 1095RC management” on page 89
  • Chapter 7, “Model 2701RC management” on page 129
  • Chapter 8, “Model 2707RC management” on page 167
  • Chapter 9, “Model 3088RC management” on page 187

For more detailed information about Model 1001MC management web pages, refer to chapter 10, “HTTP/HTML web page reference” on page 220.

Where to go next… 46

Page 47 of the Patton electronic 1001MC user manual — Table of contents
Page 47 · click to enlarge
Page 47

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 48 of the Patton electronic 1001MC user manual — Table of contents
Page 48 · click to enlarge
Page 48

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 49 of the Patton electronic 1001MC user manual — Configuration and management
Page 49 · click to enlarge
Page 49

Model 1001MC Operations Guide 4 • Model 1092ARC management

Introduction

This chapter describes managing a Model 1092ARC NetLink iDSL modem using the Model 1001MC NetLink-NMS internal HTTP/HTML web engine and a standard web browser. This chapter is meant to be used in addition to the manual that came with your unit.

NetLink-NMS description Specifically designed for use in the Patton NetLink system, when the NetLink iDSL is coupled with the Model 1001MC NetLink-NMS and the Patton Model 1001 rack system, the modem is fully SNMP manageable. SNMP management can be performed on both the local and remote units using a standard SNMP network man- agement station (NMS) or by using a standard web browser and the Model 1001MC’s built-in web server. You can view and change configuration variables, view statistical variables, and view error and warning indications.

Configuration and management

This section describes the configuration and management of your NetLink iDSL modems using a Model 1001MC NetLink-NMS with built in HTTP/HTML web server. If you plan to manage your units using a standard network management station you can download the Patton Enterprise MIBs either through the SNMP web page on the Model 1001MC or obtain them from the Patton web site at www.patton.com.

The following pages are used to configure and manage the Model 1092ARC:

  • Modem Information page: This page displays a list of the cards that are installed in your system and a quick view of any errors or warnings associated with your modems (see section “Displaying the Modem Information page” on page 50)
  • Model 1092 Configuration Slot page: This page (along with the Model 1092 Configuration—Next Configuration page) enables you to make configuration changes to the Model 1092A and the remote CPE box (see section “Displaying the Model 1092 Configuration Slot page” on page 52)
  • Model 1092 Configuration—Next Configuration page: This page (along with the Model 1092 Configuration Slot page) enables you to update configuration of modems installed in the system (see “Displaying the Model 1092 Configuration—Next Configuration page” on page 54)
  • Slot Configuration page: This page can be used to set slot-specific information related to the system and how the system treats the slot in the case of errors or warnings (see section “Displaying the Model 1092 Configuration Slot page” on page 52)

Introduction 49

Page 50 of the Patton electronic 1001MC user manual — Displaying the Modem Information page
Page 50 · click to enlarge
Page 50

Model 1001MC Operations Guide 4 • Model 1092ARC management

Displaying the Modem Information page The Modem Information page (see figure 20) displays the cards installed in the system and a quick view of any errors or warnings associated with your modems.

Patton electronic 1001MC — Displaying the Modem Information page diagram (page 50)
Fig. 27 · Displaying the Modem Information page

Figure 20. Modem Information page for the Model 1092ARC

Starting from the HOME page, to access the Modem Information page for the 1092ARC, click on the following links: Configure Cards > View Rack 1. Figure 21 on page 51 shows the web page navigation required to get to this area of the system. For more information about items on the Modem Information page, see “Displaying the Slot Configuration page” on page 56.

Configuration and management 50

Page 51 of the Patton electronic 1001MC user manual — Displaying the Modem Information page
Page 51 · click to enlarge
Page 51

Model 1001MC Operations Guide 4 • Model 1092ARC management

Patton electronic 1001MC — Displaying the Modem Information page diagram (page 51)
Fig. 28 · Displaying the Modem Information page

Figure 21. Web page navigation to Modem Information page

Configuration and management 51

Page 52 of the Patton electronic 1001MC user manual — Displaying the Model 1092 Configuration Slot page
Page 52 · click to enlarge
Page 52

Model 1001MC Operations Guide 4 • Model 1092ARC management

Displaying the Model 1092 Configuration Slot page The Model 1092 Configuration Slot page (see figure 22) enables you to make configuration changes to the Model 1092A and the remote CPE box. When the page displays, the unit is set to the onLine state and the cur- rent configuration is displayed.

Patton electronic 1001MC — Displaying the Model 1092 Configuration Slot page diagram (page 52)
Fig. 29 · Displaying the Model 1092 Configuration Slot page

Figure 22. Model 1092 Configuration Slot page

Starting from the HOME page, to access the Model 1092 Configuration Slot page for the 1092ARC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 1092ARC you wish to manage (in the example shown in figure 22, the 1092ARC was installed in slot 11). Figure 23 on page 53 shows the web page navigation required to get to this area of the system.

Configuration and management 52

Page 53 of the Patton electronic 1001MC user manual — Making configuration changes to your 1092ARC NetLink modem
Page 53 · click to enlarge
Page 53

Model 1001MC Operations Guide 4 • Model 1092ARC management

Patton electronic 1001MC — Making configuration changes to your 1092ARC NetLink modem diagram (page 53)
Fig. 30 · Making configuration changes to your 1092ARC NetLink…

Figure 23. Web page navigation to Model 1092 Configuration Slot page

Making configuration changes to your 1092ARC NetLink modem Do use the following to make configuration changes to your NetLink modem.

1. With the Model 1092 Configuration Slot page displayed, change the Input Mode (see figure 22 ) to superVisoryMode . The Modify Configuration hyperlink will appear.
2. Click on the Modify Configuration hyperlink to display the Model 1092A Next Configuration page.
3. Make your configuration changes or select the Set Default Configuration button.
4. Select the Submit Query button to place the changes into the 1001MC’s temporary memory. If you decide that you do not want your changes implemented, you can select the Clear Changes button.
5. Select the Back hyperlink to return to the Model 1092 Configuration Slot page.
6. Change the Input Mode back to onLine and select the Submit Query button. When the unit returns to the online state, the 1092A will begin implementing the configuration changes.

For more information about items on the Model 1092 Configuration Slot page, see “Model 1092 Configura- tion Slot page MIB variables description” on page 61.

Configuration and management 53

Page 54 of the Patton electronic 1001MC user manual — Displaying the Model 1092 Configuration—Next Configuration page
Page 54 · click to enlarge
Page 54

Model 1001MC Operations Guide 4 • Model 1092ARC management

Displaying the Model 1092 Configuration—Next Configuration page The Model 1092 Configuration—Next Configuration page (see figure 24) enables you to make configuration changes to the Model 1092A and the remote CPE box. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Patton electronic 1001MC — Displaying the Model 1092 Configuration—Next Configuration page diagram (page 54)
Fig. 31 · Displaying the Model 1092 Configuration—Next Configu…

Figure 24. Model 1092 Configuration—Next Configuration page

Starting from the HOME page, to access the Model 1092 Configuration—Next Configuration page for the 1092ARC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 1092ARC you wish to manage > Modify Configuration (you first have to change input mode from onLine to superVisory- Mode. Figure 25 on page 55 shows the web page navigation required to get to this area of the system.

For more information about items on the Model 1092 Configuration—Next Configuration page, see “Model 1092 Configuration—Next Configuration page MIB variables description” on page 63.

Configuration and management 54

Page 55 of the Patton electronic 1001MC user manual — Displaying the Model 1092 Configuration—Next Configuration page
Page 55 · click to enlarge
Page 55

Model 1001MC Operations Guide 4 • Model 1092ARC management

Patton electronic 1001MC — Displaying the Model 1092 Configuration—Next Configuration page diagram (page 55)
Fig. 32 · Displaying the Model 1092 Configuration—Next Configu…

Figure 25. Web page navigation to Model 1092 Configuration—Next Configuration page

Configuration and management 55

Page 56 of the Patton electronic 1001MC user manual — Displaying the Slot Configuration page
Page 56 · click to enlarge
Page 56

Model 1001MC Operations Guide 4 • Model 1092ARC management

Displaying the Slot Configuration page The Slot Configuration page (see figure 26) is used to set slot-specific information related to the system and how the system treats that slot in the case of errors or warnings.

Patton electronic 1001MC — Displaying the Slot Configuration page diagram (page 56)
Fig. 33 · Displaying the Slot Configuration page

Figure 26. Slot Configuration page

Starting from the HOME page, to access the Slot Configuration page for the 1092ARC, click on the following links: Configure Cards > View Rack 1 > Card_Address for the 1092ARC you wish to manage (in the example shown in figure 26, the 1092ARC was installed in slot 1). Figure 27 on page 57 shows the web page navigation required to get to this area of the system.

Configuration and management 56

Page 57 of the Patton electronic 1001MC user manual — Modem Information page MIB variables description
Page 57 · click to enlarge
Page 57

Model 1001MC Operations Guide 4 • Model 1092ARC management

Patton electronic 1001MC — Modem Information page MIB variables description diagram (page 57)
Fig. 34 · Modem Information page MIB variables description

Figure 27. Web page navigation to Slot Configuration page

For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description” on page 65.

Modem Information page MIB variables description

This section describes the MIB variables that are available on the Modem Information page.

Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.

Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.

Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.

If you want to protect all Model 1095RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the pop-up menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.

Modem Information page MIB variables description 57

Rack Protection Mode

Page 58 of the Patton electronic 1001MC user manual — Submit button
Page 58 · click to enlarge
Page 58

Model 1001MC Operations Guide 4 • Model 1092ARC management

Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.

Power Supply 1 Status Displays the current status of power supply 1 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Power Supply 2 Status Displays the current status of power supply 2 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.

Card Address (nmsSlotID) This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the Model 1092ARC Configuration Slot page. This page can be used to set slot-specific information about the card.

Line Status The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:

  • startup(1)
  • dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data.

Modem Information page MIB variables description 58

Page 59 of the Patton electronic 1001MC user manual — Warnings (warningCount)
Page 59 · click to enlarge
Page 59

Model 1001MC Operations Guide 4 • Model 1092ARC management

  • testMode(3)

Warnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more infor- mation on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warning for the slot can be erased in the Slot Configuration page.

Errors (errorCount) This field displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page.

Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.

Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration page for the NetLink modem and its remote unit. The model code information is passed to the Model 1001MC after the card is placed online. The Model 1001MC is auto- sensing, meaning that when a card is found or lost, the information will automatically be updated in the sys- tem. You are not required to setup the Model Code information for each slot. When a card is removed from the system, the Model Code will be erased and an error or warning will be displayed for the slot (this depends on the settings in the Slot Configuration page)

Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, you ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.

Remote Model Code (remoteModelCode) This column displays the model code of the Customer Premise NetLink modem at the far end of the link. This information is communicated from the CP box over the link to the CO Rack Card unit. The NetLink mDSL

Modem Information page MIB variables description 59

Page 60 of the Patton electronic 1001MC user manual — Protected
Page 60 · click to enlarge
Page 60

Model 1001MC Operations Guide 4 • Model 1092ARC management

rack card will then update the Model 1001MC. For this reason this information will not be available until after the link is made between the two modems.

You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed within the Configure Cards page or from the Slot Configuration page. After clicking the Sub- mit Query button to input the string to the management system, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards web page or from the Slot Configuration page.

Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Modem Information page MIB variables description 60

Protected

Page 61 of the Patton electronic 1001MC user manual — Model 1092 Configuration Slot page MIB variables description
Page 61 · click to enlarge
Page 61

Model 1001MC Operations Guide 4 • Model 1092ARC management

Model 1092 Configuration Slot page MIB variables description

This section describes the MIB variables that are available on the Model 1092 Configuration Slot page.

Model 1092A Model 1092 Configuration Slot (nmsSlotID) Displays the address of the NetLink iDSL modem. The address is defined by the DIP-switch setting of S1 on the rack card. The remote standalone unit has no address specified, but uses that address of the rack card that it is connected to.

Line Status (lineStatusiDSL) Displays the status of the line. There are three possible values that can be displayed:

  • startup(1)
  • dataMode(2)
  • testMode(3)

When the line status is dataMode(2), the units are linked-up and ready to send data.

Processor Mode (processorModeiDSL) Displays the status of the processor running on the NetLink-iDSL. There are four values that are significant to you:

  • normal(0)—When the processor is in normal(0) mode, the NetLink iDSL modem is monitoring itself and sending the status information to the Model 1001MC
  • internalProcessing(1)—When the processor is in the internalProcessing(1) mode, it is either busy downloading code to the internal DSP or setting the data pump.
  • negotiating(2)—When the processor is in the negotiating(2) mode, the card was just brought online and the NetLink-iDSL is setting up the configuration parameters within the Model 1001MC
  • lineDown(3)

At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the NetLink-iDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set- ting of the card.

Input Mode (mode1092A) The following settings are available:

  • onLine(0)
  • superVisoryMode1)

To make configuration changes to the NetLink-iDSL modems, you must first set this bit to superVisoryMode1). When the Input Mode is set to superVisoryMode1), the Modify Configuration hyperlink will appear on the web page next to the Refresh Current Page hyperlink. Select the Modify Configuration hyperlink. The Model 1092A Configuration—Next Configuration page will appear (see section “Model 1092 Configuration—Next Configuration page MIB variables description” on page 63 for more information). After making configuration changes to the NetLink-iDSL modems in the Model 1092A Update Configuration page, return to this page and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has completed and will cause it to copy the new configuration into the NetLink-iDSL

Model 1092 Configuration Slot page MIB variables description 61

Page 62 of the Patton electronic 1001MC user manual — Model 1092 Configuration Slot page Configuration Status table description
Page 62 · click to enlarge
Page 62

Model 1001MC Operations Guide 4 • Model 1092ARC management

configuration space. If this is not done, the NetLink-iDSL will not recognize the configuration changes that were made.

Model 1092 Configuration Slot page Configuration Status table description The Configuration Status table shows the configuration for the set of units. There are columns for the local and remote units. If a field is highlighted in yellow, it signifies one of two possible conditions:

  • At start up, the Model 1001MC will display a default configuration for the card and all fields will be highlighted in yellow, notifying you that the information has not been verified. During the negotiation phase, the NetLink-iDSL modem will update the configuration in the Model 1001MC with its last set of stored parameters. As these fields are updated in the Model 1001MC, the yellow highlighting will disappear, signifying that the information has been updated. After the local and remote units are linked, the units will begin updating the remote information in the table, and Line Status set to datamode(2).
  • If a rack card is installed in the rack without a customer premise unit connected, the remote information will be left as either none or highlighted in yellow, notifying you that the information has not been verified.

The following sections define the MIB variables that are shown in the Configuration Status table.

Model Code (localModelCode/remoteModelCode) These variables display the local and remote models codes for the units that were found in the specified address.

DTE rate (dteRateiDSL) This variable displays the DTE rate for the link. Because the NetLink-iDSL modems are symmetrical (same rate in both direction), there is only one MIB variable that defines the DTE rate.

Clock Mode (Local-Remote) This variable defines the clock mode for the NetLink modems. The display shows the Local clock mode (rack card) and then the remote clock mode.

TM From DTE (dteTMiDSL/remotedteTMiDSL) These MIB variables define whether you would like the modems to accept test mode requests from the DTE that is connected. In normal applications this should be set to disable(1). When the application is using rear cards or interface modules that do not have loop back ability from the DTE, such as the IM2RC/IA Ethernet rear card, this variable must be set to disable(1). In most situations, if a DTE test mode is required, it should be enable only during the time that the test is needed.

HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL) These read-only variables notify you that the specified unit has been placed into a test mode through the hard- ware. This could have been done either through the front panel switches or from the DTE (if the TM from DTE is enabled). When a test mode is displayed, the field will be highlighted in blue to give you quick notification.

SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL) These variables notify you that the specified unit has been placed into a test mode through the management station. The management can place a unit into a test mode within the Model 1092A Update Configuration page explained in more detail below.

Model 1092 Configuration Slot page MIB variables description 62

Page 63 of the Patton electronic 1001MC user manual — Model 1092 Configuration—Next Configuration page MIB variables description
Page 63 · click to enlarge
Page 63

Model 1001MC Operations Guide 4 • Model 1092ARC management

Software Rev (softVersioniDSL/remotesoftversioniDSL) These read-only MIB variables display the current version of code that is running in the NetLink-iDSL modems. Check the Download page to see if the Model 1001MC has a newer version of code available for downloading. Through the download web page, you can update the software that is running in the NetLink- iDSL rack card. You can also update the software in the NetLink stand alone unit through the front panel con- trol port on the unit.

Model 1092 Configuration—Next Configuration page MIB variables description

The Model 1092 Configuration—Next Configuration page enables you to update the configuration of the 1092ARC NetLink-iDSL modems that are installed in the system. After making changes to the configuration on this page, select Back to return to the Model 1092 Configuration Slot page, then select onLine as the Input Mode, and finally, select Submit Query to send the new information to the Model 1001MC over the network.

The following sections describes the MIB variables that are available on the Model 1092 Configuration—Next Configuration page.

Card Address (nmsSlotID) Displays the address of the selected NetLink-iDSL modem.

Line Status (lineStatusiDSL) This variable displays the status of the line. There are three possible values that can be displayed:

  • startup(1)
  • dataMode(2)—In this mode, the units are linked-up and ready to send data
  • testMode(3)

Processor Mode (processorModeiDSL) This variable displays the status of the processor running on the NetLink-iDSL. There are four values that are significant to you:

  • normal(0)—When the processor is in normal(0) mode, the NetLink - iDSL modem is monitoring itself and sending the status information to the Model 1001MC
  • internalProcessing(1)—When the processor is in the internalProcessing(1) mode, it is either busy downloading code to the internal DSP or setting the data pump.
  • negotiating(2)—When the processor is in the negotiating(2) mode, the card was just brought online and the NetLink-iDSL is setting up the configuration parameters within the Model 1001MC.
  • lineDown(3).

Model 1092 Configuration—Next Configuration page MIB variables description 63

Page 64 of the Patton electronic 1001MC user manual — Local Software Rev (softVersioniDSL)
Page 64 · click to enlarge
Page 64

Model 1001MC Operations Guide 4 • Model 1092ARC management

At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the NetLink-iDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set- ting of the card.

Local Software Rev (softVersioniDSL) These read-only MIB variable displays the current version of code that is running in the NetLink-iDSL rack card modem. You should check the download web page to see if the Model 1001MC has a newer version of code available for downloading. Through the download web page, you can update the software that is running in the NetLink-iDSL rack card.

Remote Software Rev (remotesoftversioniDSL) These read-only MIB variable displays the current version of code that is running in the NetLink-iDSL Cus- tomer Premise modem. You can update the software in the NetLink stand alone unit through the front panel control port on the unit. For more information regarding software downloads for standalone units, visit the Patton Electronics web site at www.patton.com.

Next Configuration table This table shows the configurable MIB variables for the set of units. There are column for the local and remote units. In some cases a single variable applies to both the local and remote unit. In this case, a single configura- tion field is made available in the Local column and the Remote column is made a read-only field. After changes are made, select the Submit Query button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model 1092 Configuration page.

The following sections explain the MIB variables that are shown in the Next Configuration table.

DTE rate (dteRateiDSL) This variable displays the DTE rate for the link. Because the NetLink-iDSL modems are symmetrical (same rate in both direction), there is only MIB variable that defines the DTE rate. The Customer Premise box will automatically update its' configuration to the DTE rate that is set here.

Clock Mode (Local-Remote) This variable defines the clock mode for the NetLink modems. The display shows the Local clock mode (rack card) and then the remote clock mode as a single variable in the Local column. The Remote column displays a read only field showing the remote units clocking mode. This was done to avoid an illegal configuration of the NetLink-iDSL modems. For instance, both units CAN NOT be set to internal clock. The options list all pos- sible clocking combinations.

TM From DTE (dteTMiDSL/remotedteTMiDSL) These MIB variables define whether you would like the modems to accept test mode requests from the DTE that is connected. In normal applications this should be set to disable(1). When the application is using rear cards or interface modules that do not have loop back ability from the DTE, such as the IM2RC/IA Ethernet rear card, this variable must be set to disable(1). In most situations, if a DTE test mode is required, it should be enable only during the time that the test is needed.

Test Mode (testModeSetiDSL/remotetestModeSetiDSL) These variables allow you to place the NetLink-iDSL rack card into test modes. For more information on the test modes, please see the NetLink-iDSL Test Modes section below.

Model 1092 Configuration—Next Configuration page MIB variables description 64

Page 65 of the Patton electronic 1001MC user manual — Slot Configuration page MIB variables description
Page 65 · click to enlarge
Page 65

Model 1001MC Operations Guide 4 • Model 1092ARC management

Submit Query button After making configuration changes, select the Back link, then select onLine, and finally, select Submit Query. This will submit all the configuration information to the Model 1001MC. After this, the information is stored in volatile RAM until you place the Input Mode to onLine(0). This will tell the 1001MC to copy all of the configuration information into the NetLink-iDSL configuration space.

Clear Changes Once configuration changes have been made and you have selected the Submit Query button, if you decide not to implement these changes, select the Clear Changes button. This will set the configuration back to the settings that were there when this page was entered.

Set Default Configuration Selecting this button will place the default configuration into the Next Configuration table.

Slot Configuration page MIB variables description

This section describes the MIB variables that are available on the Slot Configuration page. From the Modem Information page, the address column creates a list of hyperlinks to the Slot Configuration page associated with the specified address. The Slot Configuration page can be used to set slot-specific information related to the sys- tem and how the system treats the slot in the case of errors and warning.

Card Address (nmsSlotID) Displays the address of the card.

Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.

View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).

Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within this page.

Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, the User ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within this page.

Slot Configuration page MIB variables description 65

Card Identification Information

Page 66 of the Patton electronic 1001MC user manual — Local Circuit ID (localCircuitID)
Page 66 · click to enlarge
Page 66

Model 1001MC Operations Guide 4 • Model 1092ARC management

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.

Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warning) associated with the specified slot.

Hardware Reset (resetStatus) Selecting this push button will force the associated modem to perform a hardware reset.

Card Lost Indication (cardLostIndication) This variable allows you to choose what type of indication will be made if a modem is removed from the man- agement system. Three choices are available:

  • Error
  • Warning
  • None

Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. Three choices are available:

  • Error
  • Warning
  • None

Slot Configuration page MIB variables description 66

Alarm Information

Page 67 of the Patton electronic 1001MC user manual — Table of contents
Page 67 · click to enlarge
Page 67

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 68 of the Patton electronic 1001MC user manual — Table of contents
Page 68 · click to enlarge
Page 68

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 69 of the Patton electronic 1001MC user manual — Configuration and management
Page 69 · click to enlarge
Page 69

Model 1001MC Operations Guide 5 • Model 1094ARC management

Introduction

This chapter describes managing a Model 1094ARC NetLink HDSL modem using the Model 1001MC NetLink-NMS internal HTTP/HTML web engine and a standard web browser. This chapter is meant to be used in addition to the manual that came with your unit.

NetLink-NMS description Specifically designed for use in the Patton NetLink system, when the NetLink HDSL is coupled with the Model 1001MC NetLink-NMS and the Patton Model 1001 rack system, the modem is fully SNMP manageable. SNMP management can be performed on both the local and remote units using a standard SNMP network man- agement station (NMS) or by using a standard web browser and the Model 1001MC's built-in web server. You can view and change configuration variables, view statistical variables, and view error and warning indications.

Configuration and management

This section describes the configuration and management of your NetLink HDSL modems using a Model 1001MC NetLink-NMS with built in HTTP/HTML web server. If you plan to manage your units using a standard network management station you can download the Patton Enterprise MIBs either through the SNMP web page on the Model 1001MC or obtain them from the Patton web site at www.patton.com.

The following pages are used to configure and manage the Model 1094ARC:

  • Modem Information page: This page displays a list of the cards that are installed in your system and a quick view of any errors or warnings associated with your modems (see section “Displaying the Modem Information page” on page 70)
  • Model 1094 Configuration Slot page: This page (along with the Model 1094 Configuration—Next Configuration page) enables you to make configuration changes to the Model 1094A and the remote CPE box (see section “Displaying the Model 1094 Configuration Slot page” on page 72)
  • Model 1094 Configuration—Next Configuration page: This page (along with the Model 1094 Configuration Slot page) enables you to update configuration of modems installed in the system (see “Displaying the Model 1094 Configuration—Next Configuration page” on page 74)
  • Slot Configuration page: This page can be used to set slot-specific information related to the system and how the system treats the slot in the case of errors or warnings (see section “Displaying the Model 1094 Configuration Slot page” on page 72)
  • Download page: This page is where you can download the latest version of 1001MC and 1094ARC software (see section “Displaying the Download page” on page 77)

Introduction 69

Page 70 of the Patton electronic 1001MC user manual — Displaying the Modem Information page
Page 70 · click to enlarge
Page 70

Model 1001MC Operations Guide 5 • Model 1094ARC management

Displaying the Modem Information page The Modem Information page (see figure 28) displays the cards installed in the system and a quick view of any errors or warnings associated with your modems.

Patton electronic 1001MC — Displaying the Modem Information page diagram (page 70)
Fig. 35 · Displaying the Modem Information page

Figure 28. Modem Information page for the Model 1094ARC

Starting from the HOME page, to access the Modem Information page for the 1094ARC, click on the following links: Configure Cards > View Rack 1. Figure 29 on page 71 shows the web page navigation required to get to this area of the system. For more information about items on the Modem Information page, see “Displaying the Slot Configuration page” on page 76.

Configuration and management 70

Page 71 of the Patton electronic 1001MC user manual — Displaying the Modem Information page
Page 71 · click to enlarge
Page 71

Model 1001MC Operations Guide 5 • Model 1094ARC management

Patton electronic 1001MC — Displaying the Modem Information page diagram (page 71)
Fig. 36 · Displaying the Modem Information page

Figure 29. Web page navigation to Modem Information page

Configuration and management 71

Page 72 of the Patton electronic 1001MC user manual — Displaying the Model 1094 Configuration Slot page
Page 72 · click to enlarge
Page 72

Model 1001MC Operations Guide 5 • Model 1094ARC management

Displaying the Model 1094 Configuration Slot page The Model 1094 Configuration Slot page (see figure 30) enables you to make configuration changes to the Model 1094A and the remote CPE box. When the page displays, the unit is set to the onLine state and the cur- rent configuration is displayed.

Patton electronic 1001MC — Displaying the Model 1094 Configuration Slot page diagram (page 72)
Fig. 37 · Displaying the Model 1094 Configuration Slot page

Figure 30. Model 1094 Configuration Slot page

Starting from the HOME page, to access the Model 1094 Configuration Slot page for the 1094ARC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 1094ARC you wish to manage (in the example shown in figure 30, the 1094ARC was installed in slot 11). Figure 31 on page 73 shows the web page navigation required to get to this area of the system.

Configuration and management 72

Page 73 of the Patton electronic 1001MC user manual — Making configuration changes to your 1094ARC NetLink modem
Page 73 · click to enlarge
Page 73

Model 1001MC Operations Guide 5 • Model 1094ARC management

Patton electronic 1001MC — Making configuration changes to your 1094ARC NetLink modem diagram (page 73)
Fig. 38 · Making configuration changes to your 1094ARC NetLink…

Figure 31. Web page navigation to Model 1094 Configuration Slot page

Making configuration changes to your 1094ARC NetLink modem Do use the following to make configuration changes to your NetLink modem.

1. With the Model 1094 Configuration Slot page displayed, change the Input Mode (see figure 30 ) to superVisoryMode . The Modify Configuration hyperlink will appear.
2. Click on the Modify Configuration hyperlink to display the Model 1094A Next Configuration page.
3. Make your configuration changes or select the Set Default Configuration button.
4. Select the Submit Query button to place the changes into the 1001MC’s temporary memory. If you decide that you do not want your changes implemented, you can select the Clear Changes button.
5. Select the Back hyperlink to return to the Model 1094 Configuration Slot page.
6. Change the Input Mode back to onLine and select the Submit Query button. When the unit returns to the online state, the 1094A will begin implementing the configuration changes.

For more information about items on the Model 1094 Configuration Slot page, see “Model 1094 Configura- tion Slot page MIB variables description” on page 81.

Configuration and management 73

Page 74 of the Patton electronic 1001MC user manual — Displaying the Model 1094 Configuration—Next Configuration page
Page 74 · click to enlarge
Page 74

Model 1001MC Operations Guide 5 • Model 1094ARC management

Displaying the Model 1094 Configuration—Next Configuration page The Model 1094 Configuration—Next Configuration page (see figure 32) enables you to make configuration changes to the Model 1094A and the remote CPE box. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Patton electronic 1001MC — Displaying the Model 1094 Configuration—Next Configuration page diagram (page 74)
Fig. 39 · Displaying the Model 1094 Configuration—Next Configu…

Figure 32. Model 1094 Configuration—Next Configuration page

Starting from the HOME page, to access the Model 1094 Configuration—Next Configuration page for the 1094ARC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 1094ARC you wish to manage > Modify Configuration (you first have to change input mode from onLine to superVisory- Mode. Figure 33 on page 75 shows the web page navigation required to get to this area of the system.

For more information about items on the Model 1094 Configuration—Next Configuration page, see “Model 1094 Configuration—Next Configuration page MIB variables description” on page 84.

Configuration and management 74

Page 75 of the Patton electronic 1001MC user manual — Displaying the Model 1094 Configuration—Next Configuration page
Page 75 · click to enlarge
Page 75

Model 1001MC Operations Guide 5 • Model 1094ARC management

Patton electronic 1001MC — Displaying the Model 1094 Configuration—Next Configuration page diagram (page 75)
Fig. 40 · Displaying the Model 1094 Configuration—Next Configu…

Figure 33. Web page navigation to Model 1094 Configuration—Next Configuration page

Configuration and management 75

Page 76 of the Patton electronic 1001MC user manual — Displaying the Slot Configuration page
Page 76 · click to enlarge
Page 76

Model 1001MC Operations Guide 5 • Model 1094ARC management

Displaying the Slot Configuration page The Slot Configuration page (see figure 34) is used to set slot-specific information related to the system and how the system treats that slot in the case of errors or warnings.

Patton electronic 1001MC — Displaying the Slot Configuration page diagram (page 76)
Fig. 41 · Displaying the Slot Configuration page

Figure 34. Slot Configuration page

Starting from the HOME page, to access the Slot Configuration page for the 1094ARC, click on the following links: Configure Cards > View Rack 1 > Card_Address for the 1094ARC you wish to manage (in the example shown in figure 34, the 1094ARC was installed in slot 1). Figure 35 on page 77 shows the web page navigation required to get to this area of the system.

Configuration and management 76

Page 77 of the Patton electronic 1001MC user manual — Displaying the Download page
Page 77 · click to enlarge
Page 77

Model 1001MC Operations Guide 5 • Model 1094ARC management

Patton electronic 1001MC — Displaying the Download page diagram (page 77)
Fig. 42 · Displaying the Download page

Figure 35. Web page navigation to Slot Configuration page

For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description” on page 86.

Displaying the Download page The Download page (see figure 36) is where you can download the latest version of 1001MC and 1094ARC software.

Patton electronic 1001MC — Displaying the Download page diagram (page 77)
Fig. 43 · Displaying the Download page

Figure 36. Download page

Configuration and management 77

Page 78 of the Patton electronic 1001MC user manual — Modem Information page MIB variables description
Page 78 · click to enlarge
Page 78

Model 1001MC Operations Guide 5 • Model 1094ARC management

Starting from the HOME page, to access the Download page for the 1094ARC, click on the Download link. Figure 37 shows the web page navigation required to get to this area of the system.

Patton electronic 1001MC — Modem Information page MIB variables description diagram (page 78)
Fig. 44 · Modem Information page MIB variables description

Figure 37. Web page navigation to Download page

For more information about items on the Slot Configuration page, see “Using the Download page to upgrade 1094ARC software” on page 87.

Modem Information page MIB variables description

This section describes the MIB variables that are available on the Modem Information page.

Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.

Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.

Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.

Rack Protection Mode If you want to protect all Model 1095RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the pop-up menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.

Modem Information page MIB variables description 78

Page 79 of the Patton electronic 1001MC user manual — Submit button
Page 79 · click to enlarge
Page 79

Model 1001MC Operations Guide 5 • Model 1094ARC management

Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.

Power Supply 1 Status Displays the current status of power supply 1 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Power Supply 2 Status Displays the current status of power supply 2 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.

Card Address (nmsSlotID) This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the Model 1095 Configuration Slot page. This page can be used to set slot-specific information about the card.

Line Status The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:

  • startup(1)
  • dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data.

Modem Information page MIB variables description 79

Page 80 of the Patton electronic 1001MC user manual — Warnings (warningCount)
Page 80 · click to enlarge
Page 80

Model 1001MC Operations Guide 5 • Model 1094ARC management

  • testMode(3)

Warnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more infor- mation on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warning for the slot can be erased in the Slot Configuration page.

Errors (errorCount) This field displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page.

Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.

Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration page for the NetLink modem and its remote unit. The model code information is passed to the Model 1001MC after the card is placed online. The Model 1001MC is auto- sensing, meaning that when a card is found or lost, the information will automatically be updated in the sys- tem. You are not required to setup the Model Code information for each slot. When a card is removed from the system, the Model Code will be erased and an error or warning will be displayed for the slot (this depends on the settings in the Slot Configuration page)

Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, you ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.

Remote Model Code (remoteModelCode) This column displays the model code of the Customer Premise NetLink modem at the far end of the link. This information is communicated from the CP box over the link to the CO Rack Card unit. The NetLink mDSL

Modem Information page MIB variables description 80

Page 81 of the Patton electronic 1001MC user manual — Model 1094 Configuration Slot page MIB variables description
Page 81 · click to enlarge
Page 81

Model 1001MC Operations Guide 5 • Model 1094ARC management

rack card will then update the Model 1001MC. For this reason this information will not be available until after the link is made between the two modems.

Protected You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed within the Configure Cards page or from the Slot Configuration page. After clicking the Sub- mit Query button to input the string to the management system, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards web page or from the Slot Configuration page.

Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Model 1094 Configuration Slot page MIB variables description

This section describes the MIB variables that are available on the Model 1094 Configuration Slot page.

Model 1094A Model 1094 Configuration Slot (nmsSlotID) Displays the address of the NetLink HDSL modem. The address is defined by the DIP-switch setting of S1 on the rack card. The remote standalone unit has no address specified, but uses that address of the rack card that it is connected to.

Model 1094 Configuration Slot page MIB variables description 81

Page 82 of the Patton electronic 1001MC user manual — Line Status (lineStatus1094)
Page 82 · click to enlarge
Page 82

Model 1001MC Operations Guide 5 • Model 1094ARC management

Line Status (lineStatus1094) Displays the status of the line. There are three possible values that can be displayed:

  • startup(1)
  • dataMode(2)
  • testMode(3)

When the line status is dataMode(2), the units are linked-up and ready to send data.

Processor Mode (processorMode1094) Displays the status of the processor running on the NetLink-HDSL. There are four values that are significant to you:

  • normal(0)—When the processor is in normal(0) mode, the NetLink HDSL modem is monitoring itself and sending the status information to the Model 1001MC
  • internalProcessing(1)—When the processor is in the internalProcessing(1) mode, it is either busy downloading code to the internal DSP or setting the data pump.
  • negotiating(2)—When the processor is in the negotiating(2) mode, the card was just brought online and the NetLink-HDSL is setting up the configuration parameters within the Model 1001MC
  • lineDown(3)

At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the NetLink-HDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set- ting of the card.

Input Mode (mode1094) The following settings are available:

  • onLine(0)
  • superVisoryMode1)

To make configuration changes to the NetLink-HDSL modems, you must first set this bit to superVisoryMode1). When the Input Mode is set to superVisoryMode1), the Modify Configuration hyperlink will appear on the web page next to the Refresh Current Page hyperlink. Select the Modify Configuration hyperlink. The Model 1094A Configuration—Next Configuration page will appear (see section “Model 1094 Configuration—Next Configuration page MIB variables description” on page 84 for more information). After making configuration changes to the NetLink-HDSL modems in the Model 1094A Update Configuration page, return to this page and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has completed and will cause it to copy the new configuration into the NetLink-HDSL configuration space. If this is not done, the NetLink-HDSL will not recognize the configura- tion changes that were made.

Model 1094 Configuration Slot page Configuration Status table description The Configuration Status table shows the configuration for the set of units. There are columns for the local and remote units. If a field is highlighted in yellow, it signifies one of two possible conditions:

  • At start up, the Model 1001MC will display a default configuration for the card and all fields will be highlighted in yellow, notifying you that the information has not been verified. During the negotiation phase,

Model 1094 Configuration Slot page MIB variables description 82

Page 83 of the Patton electronic 1001MC user manual — Model Code (localModelCode/remoteModelCode)
Page 83 · click to enlarge
Page 83

Model 1001MC Operations Guide 5 • Model 1094ARC management

the NetLink-HDSL modem will update the configuration in the Model 1001MC with its last set of stored parameters. As these fields are updated in the Model 1001MC, the yellow highlighting will disappear, signi- fying that the information has been updated. After the local and remote units are linked, the units will begin updating the remote information in the table, and Line Status set to datamode(2).

  • If a rack card is installed in the rack without a customer premise unit connected, the remote information will be left as either none or highlighted in yellow, notifying you that the information has not been verified.

The following sections define the MIB variables that are shown in the Configuration Status table.

Model Code (localModelCode/remoteModelCode) These variables display the local and remote models codes for the units that were found in the specified address.

DTE rate (dteRate1094) This variable displays the DTE rate for the link. Because the NetLink-HDSL modems are symmetrical (same rate in both direction), there is only one MIB variable that defines the DTE rate.

Clock Mode (Local-Remote) This variable defines the clock mode for the NetLink modems. The display shows the Local clock mode (rack card) and then the remote clock mode.

TM From DTE (dteTM1094/remotedteTM1094) These MIB variables define whether you would like the modems to accept test mode requests from the DTE that is connected. In normal applications this should be set to disable(1). When the application is using rear cards or interface modules that do not have loop back ability from the DTE, such as the IM2RC/IA Ethernet rear card, this variable must be set to disable(1). In most situations, if a DTE test mode is required, it should be enable only during the time that the test is needed.

HW Test Mode (testModeInd1094/remotetestModeInd1094) These read-only variables notify you that the specified unit has been placed into a test mode through the hard- ware. This could have been done either through the front panel switches or from the DTE (if the TM from DTE is enabled). When a test mode is displayed, the field will be highlighted in blue to give you quick notification.

SW Test Mode (testModeSet1094/remotetestModeSet1094) These variables notify you that the specified unit has been placed into a test mode through the management station. The management can place a unit into a test mode within the Model 1094A Update Configuration page explained in more detail below.

Software Rev (softVersion1094/remotesoftversion1094) These read-only MIB variables display the current version of code that is running in the NetLink-HDSL modems. Check the Download page to see if the Model 1001MC has a newer version of code available for downloading. Through the download web page, you can update the software that is running in the NetLink- HDSL rack card. You can also update the software in the NetLink stand alone unit through the front panel control port on the unit.

Model 1094 Configuration Slot page MIB variables description 83

Page 84 of the Patton electronic 1001MC user manual — Model 1094 Configuration—Next Configuration page MIB variables description
Page 84 · click to enlarge
Page 84

Model 1001MC Operations Guide 5 • Model 1094ARC management

Model 1094 Configuration—Next Configuration page MIB variables description

The Model 1094 Configuration—Next Configuration page enables you to update the configuration of the 1094ARC NetLink-HDSL modems that are installed in the system. After making changes to the configuration on this page, select Back to return to the Model 1094 Configuration Slot page, then select onLine as the Input Mode, and finally, select Submit Query to send the new information to the Model 1001MC over the network.

The following sections describes the MIB variables that are available on the Model 1094 Configuration—Next Configuration page.

Card Address (nmsSlotID) Displays the address of the selected NetLink-HDSL modem.

Line Status (lineStatus1094) This variable displays the status of the line. There are three possible values that can be displayed:

  • startup(1)
  • dataMode(2)—In this mode, the units are linked-up and ready to send data
  • testMode(3)

Processor Mode (processorMode1094) This variable displays the status of the processor running on the NetLink-HDSL. There are four values that are significant to you:

  • normal(0)—When the processor is in normal(0) mode, the NetLink - HDSL modem is monitoring itself and sending the status information to the Model 1001MC
  • internalProcessing(1)—When the processor is in the internalProcessing(1) mode, it is either busy downloading code to the internal DSP or setting the data pump.
  • negotiating(2)—When the processor is in the negotiating(2) mode, the card was just brought online and the NetLink-HDSL is setting up the configuration parameters within the Model 1001MC.
  • lineDown(3).

At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the NetLink-HDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set- ting of the card.

Local Software Rev (softVersion1094) These read-only MIB variable displays the current version of code that is running in the NetLink-HDSL rack card modem. You should check the download web page to see if the Model 1001MC has a newer version of code available for downloading. Through the download web page, you can update the software that is running in the NetLink-HDSL rack card.

Model 1094 Configuration—Next Configuration page MIB variables description 84

Page 85 of the Patton electronic 1001MC user manual — Remote Software Rev (remotesoftversion1094)
Page 85 · click to enlarge
Page 85

Model 1001MC Operations Guide 5 • Model 1094ARC management

Remote Software Rev (remotesoftversion1094) These read-only MIB variable displays the current version of code that is running in the NetLink-HDSL Cus- tomer Premise modem. You can update the software in the NetLink stand alone unit through the front panel control port on the unit. For more information regarding software downloads for standalone units, visit the Patton Electronics web site at www.patton.com.

Next Configuration table This table shows the configurable MIB variables for the set of units. There are column for the local and remote units. In some cases a single variable applies to both the local and remote unit. In this case, a single configura- tion field is made available in the Local column and the Remote column is made a read-only field. After changes are made, select the Submit Query button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model 1094 Configuration page.

The following sections explain the MIB variables that are shown in the Next Configuration table.

DTE rate (dteRate1094) This variable displays the DTE rate for the link. Because the NetLink-HDSL modems are symmetrical (same rate in both direction), there is only MIB variable that defines the DTE rate. The Customer Premise box will automatically update its' configuration to the DTE rate that is set here.

Clock Mode (Local-Remote) This variable defines the clock mode for the NetLink modems. The display shows the Local clock mode (rack card) and then the remote clock mode as a single variable in the Local column. The Remote column displays a read only field showing the remote units clocking mode. This was done to avoid an illegal configuration of the NetLink-HDSL modems. For instance, both units CAN NOT be set to internal clock. The options list all pos- sible clocking combinations.

Tx Data Sample Point (txdEdge1095/remotetxdEdge1095) This variable defines the sampling point that is used by the NetLink-mDSL modems to read data from the DTE. In most situations it should always be set to normal(0). In high speed applications, there are situations that would require an inverted(1) sampling point.

TM From DTE (dteTM1094/remotedteTM1094) These MIB variables define whether you would like the modems to accept test mode requests from the DTE that is connected. In normal applications this should be set to disable(1). When the application is using rear cards or interface modules that do not have loop back ability from the DTE, such as the IM2RC/IA Ethernet rear card, this variable must be set to disable(1). In most situations, if a DTE test mode is required, it should be enable only during the time that the test is needed.

Test Mode (testModeSet1094/remotetestModeSet1094) These variables allow you to place the NetLink-HDSL rack card into test modes. For more information on the test modes, please see the NetLink-HDSL Test Modes section below.

Submit Query button After making configuration changes, select the Back link, then select onLine, and finally, select Submit Query. This will submit all the configuration information to the Model 1001MC. After this, the information is stored

Model 1094 Configuration—Next Configuration page MIB variables description 85

Page 86 of the Patton electronic 1001MC user manual — Slot Configuration page MIB variables description
Page 86 · click to enlarge
Page 86

Model 1001MC Operations Guide 5 • Model 1094ARC management

in volatile RAM until you place the Input Mode to onLine(0). This will tell the 1001MC to copy all of the configuration information into the NetLink-HDSL configuration space.

Clear Changes Once configuration changes have been made and you have selected the Submit Query button, if you decide not to implement these changes, select the Clear Changes button. This will set the configuration back to the settings that were there when this page was entered.

Set Default Configuration Selecting this button will place the default configuration into the Next Configuration table.

Slot Configuration page MIB variables description

This section describes the MIB variables that are available on the Slot Configuration page. From the Modem Information page, the address column creates a list of hyperlinks to the Slot Configuration page associated with the specified address. The Slot Configuration page can be used to set slot-specific information related to the sys- tem and how the system treats the slot in the case of errors and warning.

Card Address (nmsSlotID) Displays the address of the card.

Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.

View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).

Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within this page.

Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, the User ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within this page.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.

Slot Configuration page MIB variables description 86

Card Identification Information

Page 87 of the Patton electronic 1001MC user manual — Using the Download page to upgrade 1094ARC software
Page 87 · click to enlarge
Page 87

Model 1001MC Operations Guide 5 • Model 1094ARC management

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.

Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warning) associated with the specified slot.

Hardware Reset (resetStatus) Selecting this push button will force the associated modem to perform a hardware reset.

Card Lost Indication (cardLostIndication) This variable allows you to choose what type of indication will be made if a modem is removed from the man- agement system. Three choices are available:

  • Error
  • Warning
  • None

Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. Three choices are available:

  • Error
  • Warning
  • None

Using the Download page to upgrade 1094ARC software

Do the following to download new software into your NetLink modem:

1. Remove the card that you wish to upgrade from the rack chassis.
2. Make a note of the settings of DIP switches S2-6 and S2-7.
3. Set DIP switches S2-6 and S2-7 to the OFF position.

Using the Download page to upgrade 1094ARC software 87

Alarm Information

Page 88 of the Patton electronic 1001MC user manual — Remote Circuit ID (remoteCircuitID)
Page 88 · click to enlarge
Page 88

Model 1001MC Operations Guide 5 • Model 1094ARC management

4. Click on the Download 1094ARC Software button (see figure 38 ).
Patton electronic 1001MC — Remote Circuit ID (remoteCircuitID) diagram (page 88)
Fig. 45 · Remote Circuit ID (remoteCircuitID)

Figure 38. Download 1094ARC software button

5. Select the View Status hyperlink (see figure 39 )
Patton electronic 1001MC — Remote Circuit ID (remoteCircuitID) diagram (page 88)
Fig. 46 · Remote Circuit ID (remoteCircuitID)

Figure 39. View Status link location

6. Slide the card into the chassis. You will see the download status updated in the window as the download progresses.
7. When the download is complete, remove the card from the rack and return DIP switches S2-6 and S-7 to their original positions.
8. Return to the modem configuration page and verify the proper configuration for your modem.

Congratulation! The software has been successfully upgraded.

Using the Download page to upgrade 1094ARC software 88

Page 89 of the Patton electronic 1001MC user manual — Table of contents
Page 89 · click to enlarge
Page 89

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 90 of the Patton electronic 1001MC user manual — Table of contents
Page 90 · click to enlarge
Page 90

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 91 of the Patton electronic 1001MC user manual — Table of contents
Page 91 · click to enlarge
Page 91

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 92 of the Patton electronic 1001MC user manual — Configuration and management
Page 92 · click to enlarge
Page 92

Introduction

This chapter describes managing a Model 1095RC NetLink mDSL modem using the Model 1001MC NetLink-NMS internal HTTP/HTML web engine and a standard web browser. This chapter is meant to be used in addition to the manual that came with your unit.

NetLink-NMS description Specifically designed for use in the Patton NetLink system, when the NetLink mDSL is coupled with the Model 1001MC NetLink-NMS and the Patton Model 1001 rack system, the modem is fully SNMP manageable. SNMP management can be performed on both the local and remote units using a standard SNMP network man- agement station (NMS) or by using a standard web browser and the Model 1001MC's built-in web server. You can view and change configuration variables, view statistical variables, and view error and warning indications.

Configuration and management

This section describes the configuration and management of your NetLink mDSL modems using a Model 1001MC NetLink-NMS with built in HTTP/HTML web server. If you plan to manage your units using a standard network management station you can download the Patton Enterprise MIBs either through the SNMP web page on the Model 1001MC or obtain them from the Patton web site at www.patton.com.

The following pages are used to configure and manage the Model 1095RC:

  • Global Configuration Menu page: Model 1095RC rack cards can be configured globally by templates you create. If you use this capability, you have the option to globally configure some or all Model 1095RC modems in multiple racks, or those in just one rack (see section “Displaying the Global Configuration Menu page” on page 93).
  • Modem Information page: This page displays a list of the cards that are installed in your system and a quick view of any errors or warnings associated with your modems (see section “Displaying the Modem Information page” on page 94).
  • Model 1095 Configuration Slot page: This page (along with the Model 1095 Configuration—Next Configuration page) enables you to make configuration changes to the Model 1095RC and the remote CPE box (see section “Displaying the Model 1095 Configuration Slot page” on page 95).
  • Model 1095 Configuration—Next Configuration page: This page (along with the Model 1095 Configuration Slot page) enables you to update configuration of modems installed in the system (see “Displaying the Model 1095 Configuration—Next Configuration page” on page 97).
  • Slot Configuration page: This page can be used to set slot-specific information related to the system and how the system treats the slot in the case of errors or warnings (see section “Displaying the Model 1095 Configuration Slot page” on page 95).
  • Download page: This page is where you can download the latest version of 1001MC and 1095RC software (see section “Displaying the Download page” on page 100).

Introduction 92

Page 93 of the Patton electronic 1001MC user manual — Displaying the Global Configuration Menu page
Page 93 · click to enlarge
Page 93

Displaying the Global Configuration Menu page The Global Configuration Menu page (see figure 40) is where you can create templates that can globally config- ure the Model 1095RC. With this capability, you can globally configure some or all Model 1095RC modems in multiple racks, or just one rack.

Patton electronic 1001MC — Displaying the Global Configuration Menu page diagram (page 93)
Fig. 47 · Displaying the Global Configuration Menu page

Figure 40. Global Configuration Menu page for the Model 1095RC

Starting from the HOME page, to access the Modem Information page for the 1095RC, click on the System Con- fig link. Figure 41 shows the web page navigation required to get to this area of the system. For more informa- tion about items on the Global Configuration Menu page, see “Creating and modifying global configuration templates” on page 113.

Patton electronic 1001MC — Displaying the Global Configuration Menu page diagram (page 93)
Fig. 48 · Displaying the Global Configuration Menu page

Figure 41. Web page navigation to Global Configuration Menu page

Configuration and management 93

Page 94 of the Patton electronic 1001MC user manual — Displaying the Modem Information page
Page 94 · click to enlarge
Page 94

Displaying the Modem Information page The Modem Information page (see figure 42) displays the cards installed in the system and a quick view of any errors or warnings associated with your modems.

Patton electronic 1001MC — Displaying the Modem Information page diagram (page 94)
Fig. 49 · Displaying the Modem Information page

Figure 42. Modem Information page for the Model 1095RC

Starting from the HOME page, to access the Modem Information page for the 1095RC, click on the following links: Configure Cards > View Rack 1. Figure 43 shows the web page navigation required to get to this area of the system. For more information about items on the Modem Information page, see “Displaying the Slot Con- figuration page” on page 99.

Patton electronic 1001MC — Displaying the Modem Information page diagram (page 94)
Fig. 50 · Displaying the Modem Information page

Figure 43. Web page navigation to Modem Information page

Configuration and management 94

Page 95 of the Patton electronic 1001MC user manual — Displaying the Model 1095 Configuration Slot page
Page 95 · click to enlarge
Page 95

Displaying the Model 1095 Configuration Slot page The Model 1095 Configuration Slot page (see figure 44) enables you to make configuration changes to the Model 1095RC and the remote CPE box. When the page displays, the unit is set to the onLine state and the cur- rent configuration is displayed.

Patton electronic 1001MC — Displaying the Model 1095 Configuration Slot page diagram (page 95)
Fig. 51 · Displaying the Model 1095 Configuration Slot page

Figure 44. Model 1095 Configuration Slot page

Starting from the HOME page, to access the Model 1095 Configuration Slot page for the 1095RC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 1095RC you wish to manage (in the example shown in figure 44, the 1095RC was installed in slot 11). Figure 45 on page 96 shows the web page navigation required to get to this area of the system.

Configuration and management 95

Page 96 of the Patton electronic 1001MC user manual — Making configuration changes to your 1095RC NetLink modem
Page 96 · click to enlarge
Page 96
Patton electronic 1001MC — Making configuration changes to your 1095RC NetLink modem diagram (page 96)
Fig. 52 · Making configuration changes to your 1095RC NetLink…

Figure 45. Web page navigation to Model 1095 Configuration Slot page

Making configuration changes to your 1095RC NetLink modem Do use the following to make configuration changes to your NetLink modem.

1. With the Model 1095 Configuration Slot page displayed, change the Input Mode (see figure 44 ) to superVisoryMode . The Modify Configuration hyperlink will appear.
2. Click on the Modify Configuration hyperlink to display the Model 1095RC Next Configuration page.
3. Make your configuration changes or select the Set Default Configuration button.
4. Select the Submit Query button to place the changes into the 1001MC’s temporary memory. If you decide that you do not want your changes implemented, you can select the Clear Changes button.
5. Select the Back hyperlink to return to the Model 1095 Configuration Slot page.
6. Change the Input Mode back to onLine and select the Submit Query button. When the unit returns to the online state, the 1095RC will begin implementing the configuration changes.

For more information about items on the Model 1095 Configuration Slot page, see “After submitting the remote circuit ID information, you must click on the Record Current Configuration button located on the HOME page to store the configuration changes into memory (see “HOME” on page 228 for more informa- tion).” on page 104.

Configuration and management 96

Page 97 of the Patton electronic 1001MC user manual — Displaying the Model 1095 Configuration—Next Configuration page
Page 97 · click to enlarge
Page 97

Displaying the Model 1095 Configuration—Next Configuration page The Model 1095 Configuration—Next Configuration page (see figure 46) enables you to make configuration changes to the Model 1095RC and the remote CPE box. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Patton electronic 1001MC — Displaying the Model 1095 Configuration—Next Configuration page diagram (page 97)
Fig. 53 · Displaying the Model 1095 Configuration—Next Configu…

Figure 46. Model 1095 Configuration—Next Configuration page

Starting from the HOME page, to access the Model 1095 Configuration—Next Configuration page for the 1095RC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 1095RC you wish to manage > Modify Configuration (you first have to change input mode from onLine to superVisoryMode. Figure 47 on page 98 shows the web page navigation required to get to this area of the system.

For more information about items on the Model 1095 Configuration—Next Configuration page, see “Model 1095 Configuration—Next Configuration page MIB variables description” on page 107.

Configuration and management 97

Page 98 of the Patton electronic 1001MC user manual — Displaying the Model 1095 Configuration—Next Configuration page
Page 98 · click to enlarge
Page 98
Patton electronic 1001MC — Displaying the Model 1095 Configuration—Next Configuration page diagram (page 98)
Fig. 54 · Displaying the Model 1095 Configuration—Next Configu…

Figure 47. Web page navigation to Model 1095 Configuration—Next Configuration page

Configuration and management 98

Page 99 of the Patton electronic 1001MC user manual — Displaying the Slot Configuration page
Page 99 · click to enlarge
Page 99

Displaying the Slot Configuration page The Slot Configuration page (see figure 48) is used to set slot-specific information related to the system and how the system treats that slot in the case of errors or warnings.

Patton electronic 1001MC — Displaying the Slot Configuration page diagram (page 99)
Fig. 55 · Displaying the Slot Configuration page

Figure 48. Slot Configuration page

Starting from the HOME page, to access the Slot Configuration page for the 1095RC, click on the following links: Configure Cards > View Rack 1 > Card_Address for the 1095RC you wish to manage (in the example shown in figure 48, the 1095RC was installed in slot 1). Figure 49 on page 100 shows the web page navigation required to get to this area of the system.

Configuration and management 99

Page 100 of the Patton electronic 1001MC user manual — Displaying the Download page
Page 100 · click to enlarge
Page 100
Patton electronic 1001MC — Displaying the Download page diagram (page 100)
Fig. 56 · Displaying the Download page

Figure 49. Web page navigation to Slot Configuration page

For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description” on page 110.

Displaying the Download page The Download page (see figure 50) is where you can download the latest version of 1001MC and 1095RC software.

Figure 50. Download page

Configuration and management 100

Page 101 of the Patton electronic 1001MC user manual — Modem Information page MIB variables description
Page 101 · click to enlarge
Page 101

Starting from the HOME page, to access the Download page for the 1095RC, click on the Download link. Figure 51 shows the web page navigation required to get to this area of the system.

Patton electronic 1001MC — Modem Information page MIB variables description diagram (page 101)
Fig. 57 · Modem Information page MIB variables description

Figure 51. Web page navigation to Download page

For more information about items on the Download page, see “Using the Download page to upgrade 1095RC software” on page 111.

Modem Information page MIB variables description

This section describes the MIB variables that are available on the Modem Information page.

Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.

Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.

Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.

Rack Protection Mode If you want to protect all Model 1095RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the pop-up menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.

Modem Information page MIB variables description 101

Page 102 of the Patton electronic 1001MC user manual — Submit button
Page 102 · click to enlarge
Page 102

Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.

Power Supply 1 Status Displays the current status of power supply 1 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Power Supply 2 Status Displays the current status of power supply 2 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.

Card Address (nmsSlotID) This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the Model 1095 Configuration Slot page. This page can be used to set slot-specific information about the card.

Line Status The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:

  • startup(1)
  • dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data.

Modem Information page MIB variables description 102

Page 103 of the Patton electronic 1001MC user manual — Warnings (warningCount)
Page 103 · click to enlarge
Page 103
  • testMode(3)

Warnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more infor- mation on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warning for the slot can be erased in the Slot Configuration page.

Errors (errorCount) This field displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page.

Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.

Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration page for the NetLink modem and its remote unit. The model code information is passed to the Model 1001MC after the card is placed online. The Model 1001MC is auto- sensing, meaning that when a card is found or lost, the information will automatically be updated in the sys- tem. You are not required to setup the Model Code information for each slot. When a card is removed from the system, the Model Code will be erased and an error or warning will be displayed for the slot (this depends on the settings in the Slot Configuration page)

Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, you ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.

Remote Model Code (remoteModelCode) This column displays the model code of the Customer Premise NetLink modem at the far end of the link. This information is communicated from the CP box over the link to the CO Rack Card unit. The NetLink mDSL

Modem Information page MIB variables description 103

Page 104 of the Patton electronic 1001MC user manual — Model 1095 Configuration Slot page MIB variables description
Page 104 · click to enlarge
Page 104

rack card will then update the Model 1001MC. For this reason this information will not be available until after the link is made between the two modems.

Protected You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed within the Configure Cards page or from the Slot Configuration page. After clicking the Sub- mit Query button to input the string to the management system, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards web page or from the Slot Configuration page.

Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Model 1095 Configuration Slot page MIB variables description

This section describes the MIB variables that are available on the Model 1095 Configuration Slot page.

Model 1095RC Model 1095 Configuration Slot (nmsSlotID) Displays the address of the NetLink mDSL modem. The address is defined by the DIP-switch setting of S1 on the rack card. The remote standalone unit has no address specified, but uses that address of the rack card that it is connected to.

Model 1095 Configuration Slot page MIB variables description 104

Page 105 of the Patton electronic 1001MC user manual — Line Status (lineStatus1095)
Page 105 · click to enlarge
Page 105

Line Status (lineStatus1095) Displays the status of the line. There are three possible values that can be displayed:

  • startup(1)
  • dataMode(2)
  • testMode(3)

When the line status is dataMode(2), the units are linked-up and ready to send data.

Processor Mode (processorMode1095) Displays the status of the processor running on the NetLink-mDSL. There are four values that are significant to you:

  • normal(0)—When the processor is in normal(0) mode, the NetLink mDSL modem is monitoring itself and sending the status information to the Model 1001MC
  • internalProcessing(1)—When the processor is in the internalProcessing(1) mode, it is either busy downloading code to the internal DSP or setting the data pump.
  • negotiating(2)—When the processor is in the negotiating(2) mode, the card was just brought online and the NetLink-mDSL is setting up the configuration parameters within the Model 1001MC
  • lineDown(3)

At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the NetLink-mDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set- ting of the card.

Previous Card button Click the Previous Card button to display the rack card configuration in the next occupied slot (in descend- ing order).

Refresh Current Page button Clicking the Refresh Current Page button displays updated configuration information.

Next Card button Click the Next Card button to display the rack card configuration in the next occupied slot (in descending order).

View Rack X hyperlink Click on this link to display the Modem Information Rack X page. The Modem Information Rack page displays an overview of the NetLink rack that is being managed. For more information, refer to section “Modem Informa- tion Rack X” on page 239.

Model 1095 Configuration Slot page MIB variables description 105

Page 106 of the Patton electronic 1001MC user manual — Input Mode (mode1095)
Page 106 · click to enlarge
Page 106

Input Mode (mode1095) The following settings are available:

  • onLine(0)
  • superVisoryMode1)

To make configuration changes to the NetLink-mDSL modems, you must first set this bit to superVisoryMode1). When the Input Mode is set to superVisoryMode1), the Modify Configuration hyperlink will appear on the web page next to the Refresh Current Page hyperlink. Select the Modify Configuration hyperlink. The Model 1095RC Configuration—Next Configuration page will appear (see section “Model 1095 Configuration—Next Configuration page MIB variables description” on page 107 for more information). After making configuration changes to the NetLink-mDSL modems in the Model 1095RC Update Configura- tion page, return to this page and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has completed and will cause it to copy the new configuration into the NetLink-mDSL configuration space. If this is not done, the NetLink-mDSL will not recognize the configura- tion changes that were made.

Model 1095 Configuration Slot page Configuration Status table description The Configuration Status table shows the configuration for the set of units. There are columns for the local and remote units. If a field is highlighted in yellow, it signifies one of two possible conditions:

  • At start up, the Model 1001MC will display a default configuration for the card and all fields will be highlighted in yellow, notifying you that the information has not been verified. During the negotiation phase, the NetLink-mDSL modem will update the configuration in the Model 1001MC with its last set of stored parameters. As these fields are updated in the Model 1001MC, the yellow highlighting will disappear, signifying that the information has been updated. After the local and remote units are linked, the units will begin updating the remote information in the table, and Line Status set to datamode(2).
  • If a rack card is installed in the rack without a customer premise unit connected, the remote information will be left as either none or highlighted in yellow, notifying you that the information has not been verified.

The following sections define the MIB variables that are shown in the Configuration Status table.

Model Code (localModelCode/remoteModelCode) These variables display the local and remote models codes for the units that were found in the specified address.

DTE rate (dteRate1095) This variable displays the DTE rate for the link. Because the NetLink-mDSL modems are symmetrical (same rate in both direction), there is only one MIB variable that defines the DTE rate.

Clock Mode (Local-Remote) This variable defines the clock mode for the NetLink modems. The display shows the Local clock mode (rack card) and then the remote clock mode.

Tx Data Sample Point (txdEdge1095/remotetxdEdge1095) This variable defines the sampling point that is used by the NetLink-mDSL modems to read data from the DTE. In most situations it should always be set to normal(0). In high speed applications, there are situations that would require an inverted(1) sampling point.

Model 1095 Configuration Slot page MIB variables description 106

Page 107 of the Patton electronic 1001MC user manual — Model 1095 Configuration—Next Configuration page MIB variables description
Page 107 · click to enlarge
Page 107

TM From DTE (dteTM1095/remotedteTM1095) These MIB variables define whether you would like the modems to accept test mode requests from the DTE that is connected. In normal applications this should be set to disable(1). When the application is using rear cards or interface modules that do not have loop back ability from the DTE, such as the IM2RC/IA Ethernet rear card, this variable must be set to disable(1). In most situations, if a DTE test mode is required, it should be enable only during the time that the test is needed.

Framing Mode This bit defines the mode of operation of the interface. For standard serial interfaces Framing Mode should be set to normal(3). Please refer to the user manual that came with the Model 1095RC for more information.

Note Framing mode was introduced into the Model 1095RC modems at software revision 2.2.0. If you have a modem with a software revision earlier than this it will ignore the framing mode bit. On the 1001MC web page the bit will always be highlighted in yellow showing that the bit is not being updated. Contact Patton Electronics for software upgrades for your units if you require this feature.

HW Test Mode (testModeInd1095/remotetestModeInd1095) These read-only variables notify you that the specified unit has been placed into a test mode through the hard- ware. This could have been done either through the front panel switches or from the DTE (if the TM from DTE is enabled). When a test mode is displayed, the field will be highlighted in blue to give you quick notification.

SW Test Mode (testModeSet1095/remotetestModeSet1095) These variables notify you that the specified unit has been placed into a test mode through the management station. The management can place a unit into a test mode within the Model 1095RC Update Configuration page explained in more detail below.

Software Rev (softVersion1095/remotesoftversion1095) These read-only MIB variables display the current version of code that is running in the NetLink-mDSL modems. Check the Download page to see if the Model 1001MC has a newer version of code available for downloading. Through the download web page, you can update the software that is running in the NetLink- mDSL rack card. You can also update the software in the NetLink stand alone unit through the front panel control port on the unit.

Model 1095 Configuration—Next Configuration page MIB variables description

The Model 1095 Configuration—Next Configuration page enables you to update the configuration of the 1095RC NetLink-mDSL modems that are installed in the system. After making changes to the configuration on this page, select Back to return to the Model 1095 Configuration Slot page, then select onLine as the Input Mode, and finally, select Submit Query to send the new information to the Model 1001MC over the network.

Model 1095 Configuration—Next Configuration page MIB variables description 107

Page 108 of the Patton electronic 1001MC user manual — Card Address (nmsSlotID)
Page 108 · click to enlarge
Page 108

The following sections describes the MIB variables that are available on the Model 1095 Configuration—Next Configuration page.

Card Address (nmsSlotID) Displays the address of the selected NetLink-mDSL modem.

Line Status (lineStatus1095) This variable displays the status of the line. There are three possible values that can be displayed:

  • startup(1)
  • dataMode(2)—In this mode, the units are linked-up and ready to send data
  • testMode(3)

Processor Mode (processorMode1095) This variable displays the status of the processor running on the NetLink-mDSL. There are four values that are significant to you:

  • normal(0)—When the processor is in normal(0) mode, the NetLink - mDSL modem is monitoring itself and sending the status information to the Model 1001MC
  • internalProcessing(1)—When the processor is in the internalProcessing(1) mode, it is either busy downloading code to the internal DSP or setting the data pump.
  • negotiating(2)—When the processor is in the negotiating(2) mode, the card was just brought online and the NetLink-mDSL is setting up the configuration parameters within the Model 1001MC.
  • lineDown(3).

At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the NetLink-mDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set- ting of the card.

Local Software Rev (softVersion1095) These read-only MIB variable displays the current version of code that is running in the NetLink-mDSL rack card modem. You should check the download web page to see if the Model 1001MC has a newer version of code available for downloading. Through the download web page, you can update the software that is running in the NetLink-mDSL rack card.

Remote Software Rev (remotesoftversion1095) These read-only MIB variable displays the current version of code that is running in the NetLink-mDSL Cus- tomer Premise modem. You can update the software in the NetLink stand alone unit through the front panel control port on the unit. For more information regarding software downloads for standalone units, visit the Patton Electronics web site at www.patton.com.

Back… hyperlink After making modifications, click the Back hyperlink, thereby returning the unit to onLine mode to implement the changes.

Model 1095 Configuration—Next Configuration page MIB variables description 108

Page 109 of the Patton electronic 1001MC user manual — Next Configuration table
Page 109 · click to enlarge
Page 109

Next Configuration table This table shows the configurable MIB variables for the set of units. There are column for the local and remote units. In some cases a single variable applies to both the local and remote unit. In this case, a single configura- tion field is made available in the Local column and the Remote column is made a read-only field. After changes are made, select the Submit Query button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model 1095 Configuration page.

The following sections explain the MIB variables that are shown in the Next Configuration table.

DTE rate (dteRate1095) This variable displays the DTE rate for the link. Because the NetLink-mDSL modems are symmetrical (same rate in both direction), there is only MIB variable that defines the DTE rate. The Customer Premise box will automatically update its' configuration to the DTE rate that is set here.

Clock Mode (Local-Remote) This variable defines the clock mode for the NetLink modems. The display shows the Local clock mode (rack card) and then the remote clock mode as a single variable in the Local column. The Remote column displays a read only field showing the remote units clocking mode. This was done to avoid an illegal configuration of the NetLink-mDSL modems. For instance, both units CAN NOT be set to internal clock. The options list all pos- sible clocking combinations.

Tx Data Sample Point (txdEdge1095/remotetxdEdge1095) This variable defines the sampling point that is used by the NetLink-mDSL modems to read data from the DTE. In most situations it should always be set to normal(0). In high speed applications, there are situations that would require an inverted(1) sampling point.

TM From DTE (dteTM1095/remotedteTM1095) These MIB variables define whether you would like the modems to accept test mode requests from the DTE that is connected. In normal applications this should be set to disable(1). When the application is using rear cards or interface modules that do not have loop back ability from the DTE, such as the IM2RC/IA Ethernet rear card, this variable must be set to disable(1). In most situations, if a DTE test mode is required, it should be enable only during the time that the test is needed.

Framing Mode This bit defines the mode of operation of the interface. The following options are available:

  • normal(3)
  • slotted(1)

For standard serial interfaces Framing Mode should be set to normal(3). Please refer to the user manual that came with the Model 1095RC for more information.

Note Framing mode was introduced into the Model 1095RC modems at software revision 2.2.0. If you have a modem with a software revision earlier than this it will ignore the framing mode bit. On the 1001MC web page the bit will always be highlighted in yellow showing that the bit is not being updated. Contact Patton Electronics for software upgrades for your units if you require this feature.

Model 1095 Configuration—Next Configuration page MIB variables description 109

Page 110 of the Patton electronic 1001MC user manual — Slot Configuration page MIB variables description
Page 110 · click to enlarge
Page 110

Test Mode (testModeSet1095/remotetestModeSet1095) These variables allow you to place the NetLink-mDSL rack card into test modes. For more information on the test modes, please see the NetLink-mDSL Test Modes section below.

Submit Query button After making configuration changes, select the Back link, then select onLine, and finally, select Submit Query. This will submit all the configuration information to the Model 1001MC. After this, the information is stored in volatile RAM until you place the Input Mode to onLine(0). This will tell the 1001MC to copy all of the configuration information into the NetLink-mDSL configuration space.

Clear Changes Once configuration changes have been made and you have selected the Submit Query button, if you decide not to implement these changes, select the Clear Changes button. This will set the configuration back to the settings that were there when this page was entered.

Set Default Configuration Selecting this button will place the default configuration into the Next Configuration table.

Slot Configuration page MIB variables description

This section describes the MIB variables that are available on the Slot Configuration page. From the Modem Information page, the address column creates a list of hyperlinks to the Slot Configuration page associated with the specified address. The Slot Configuration page can be used to set slot-specific information related to the sys- tem and how the system treats the slot in the case of errors and warning.

Card Address (nmsSlotID) Displays the address of the card.

Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.

View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).

Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within this page.

Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, the User ID will move to the new slot making it

Slot Configuration page MIB variables description 110

Card Identification Information

Page 111 of the Patton electronic 1001MC user manual — Using the Download page to upgrade 1095RC software
Page 111 · click to enlarge
Page 111

useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within this page.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.

Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warning) associated with the specified slot.

Hardware Reset (resetStatus) Selecting this push button will force the associated modem to perform a hardware reset.

Card Lost Indication (cardLostIndication) This variable allows you to choose what type of indication will be made if a modem is removed from the man- agement system. Three choices are available:

  • Error
  • Warning
  • None

Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. Three choices are available:

  • Error
  • Warning
  • None

Using the Download page to upgrade 1095RC software

Do the following to download new software into your NetLink modem:

1. Remove the card that you wish to upgrade from the rack chassis.
2. Make a note of the settings of DIP switches S2-6 and S2-7.
3. Set DIP switches S2-6 and S2-7 to the OFF position.

Using the Download page to upgrade 1095RC software 111

Alarm Information

Page 112 of the Patton electronic 1001MC user manual — Local Circuit ID (localCircuitID)
Page 112 · click to enlarge
Page 112
4. If you are upgrading Model 1095RC software, click on the Download 1095RC Software button (see figure 52 ). Otherwise, go to step 8 to download the latest version of the 1095RC Key software.
Patton electronic 1001MC — Local Circuit ID (localCircuitID) diagram (page 112)
Fig. 58 · Local Circuit ID (localCircuitID)

Figure 52. Download 1095RC software button

5. Select the View Status hyperlink (see figure 53 ).

Figure 53. View Status link location

6. Slide the card into the chassis. You will see the download status updated in the window as the download progresses.
7. When the download is complete, if you are also going to download the latest 1095RC Key software go to step 8. Otherwise, go to step 12.
8. Remove the card from the rack chassis.
9. Click on the Download 1095RC Key button to download the 1095RC Key software.
10. Select the View Status hyperlink (see figure 53 ).
11. Slide the card into the chassis. You will see the download status updated in the window as the download progresses.
12. Remove the card from the rack and return DIP switches S2-6 and S-7 to their original positions.
13. Return to the modem configuration page and verify the proper configuration for your modem.

Congratulation! The software has been successfully upgraded.

Using the Download page to upgrade 1095RC software 112

Page 113 of the Patton electronic 1001MC user manual — Creating and modifying global configuration templates
Page 113 · click to enlarge
Page 113

Creating and modifying global configuration templates

Model 1095RC rack cards can be configured globally by templates you create. If you use this capability, you have the option to globally configure some or all Model 1095RC modems in multiple racks, or those in just one rack.

This section contains the following information to help you configure and use templates:

  • Protecting individual Model 1001 racks and 1095RC rack cards from global modification—You may not want all racks or modems to be modified when you apply the global template, so section “Protecting Model 1001 racks and Model 1095RC modems from global modification” describes how to protect individual 1001 racks and 1095RC modems from being globally configured.
  • Creating a template (see section “Creating a template” on page 117)
  • Modifying a template (see section “Modifying a template” on page 121)
  • Deleting a template (see section “” on page 125)
  • Applying a template (see section

Protecting Model 1001 racks and Model 1095RC modems from global modification This section describes how to protect 1001 racks and 1095RC modem cards from being modified when a glo- bal modification is applied. This is useful if you are setting all but a few cards to the same configuration.

Select the appropriate option from following configuration choices:

  • Protect a Model 1001 rack (see section “Protecting a Model 1001 rack from global configuration” on page 114)
  • Protect a Model 1095RC rack card (see section “Protecting a Model 1095RC rack card from global configuration” on page 116)

Creating and modifying global configuration templates 113

Page 114 of the Patton electronic 1001MC user manual — Protecting a Model 1001 rack from global configuration
Page 114 · click to enlarge
Page 114

Protecting a Model 1001 rack from global configuration Do the following to protect a Model 1001 rack:

1. Starting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 54 . Figure 55 on page 115 shows the web page navigation required to get to this area of the system.
Patton electronic 1001MC — Protecting a Model 1001 rack from global configuration diagram (page 114)
Fig. 59 · Protecting a Model 1001 rack from global configurati…

Figure 54. System Level Information page

Creating and modifying global configuration templates 114

Page 115 of the Patton electronic 1001MC user manual — Protecting a Model 1001 rack from global configuration
Page 115 · click to enlarge
Page 115
Patton electronic 1001MC — Protecting a Model 1001 rack from global configuration diagram (page 115)
Fig. 60 · Protecting a Model 1001 rack from global configurati…

Figure 55. Web page navigation to System Level Information page

2. Use the Rack Protection Mode pop-up menu (see figure 54 ) to select protected(1) .
3. Click the Apply Protection button.

The rack is now protected.

Creating and modifying global configuration templates 115

Page 116 of the Patton electronic 1001MC user manual — Protecting a Model 1095RC rack card from global configuration
Page 116 · click to enlarge
Page 116

Protecting a Model 1095RC rack card from global configuration Do the following to protect a single Model 1095RC rack card:

1. Starting from the HOME page, click on the following links: Configure Cards > View Rack 1 (choose the rack you want to protect, in the example shown in figure 56 , rack 1 was selected). Figure 57 shows the web page navigation required to get to this area of the system.
Patton electronic 1001MC — Protecting a Model 1095RC rack card from global configuration diagram (page 116)
Fig. 61 · Protecting a Model 1095RC rack card from global conf…

Figure 56. Modem Information Rack 1 page

Patton electronic 1001MC — Protecting a Model 1095RC rack card from global configuration diagram (page 116)
Fig. 62 · Protecting a Model 1095RC rack card from global conf…

Figure 57. Web page navigation to Modem Information Rack 1 page

Creating and modifying global configuration templates 116

Page 117 of the Patton electronic 1001MC user manual — Creating a template
Page 117 · click to enlarge
Page 117
2. Locate the card address (see figure 56 on page 116) of the Model 1095RC you want to protect.
3. Set the Protected pop-up menu (see figure 56 on page 116) to protected(1) .
4. Click the Submit button.

The rack card is now protected.

Creating a template This section describes how to create a global configuration template. The Patton Model 1095 enables the Model 1001MC system administrator to configure the units for a wide variety of applications. Due to the many different applications that are supported, care must be taken when setting the configuration of your modems. There are several illegal combinations of variables that could cause problems with the modems if implemented incorrectly. Be sure to read the following information before creating a template:

  • Configuration rules—Things to keep in mind when creating a template (see section “Configuration rules” on page 117)
  • Notes on clock mode settings (see section “Notes on clock mode settings” on page 118)
  • Notes on framing mode settings (see section “Notes on framing mode settings” on page 118)
  • Illegal configuration messages (see section “Illegal configuration messages” on page 118)

After reviewing the rules and notes, go to section “Procedure for creating a template” on page 119 to learn how to create a template.

Configuration rules Keep in mind the following when creating a template:

  • If you have an IM2RC/K G.703/G.704 Rear Card installed with a 1095RC in your rack, the unit must have the Local Clock Mode set to external and the Framing Mode set to slotted .
  • If you have an IM1/K G.703/G.704 Quick Connect Module installed with your 1095 at the remote site, the units must have the Clock Mode set to external-external and the Framing Mode for both the local and remote units must be set to slotted .
  • If you have any other interface connected to your 1095RC or your 1095 modems, the Framing Mode must be set to normal .
  • The system administrator should only set the Clock Mode to external-external(4) if there is an IM2RC/K installed in the 1095RC at the rack and an IM1/K installed in the 1095 standalone unit at the remote site.
  • When setting a unit for the external clock mode, the unit must have an external clock source in order to make a link. When using either an IM2RC/K or an IM1/K, the K module will always provide the external clock for the unit, so it is not necessary to have a G.703/G.704 link available. When using any other type of serial interface, make sure that an external clock is provided by the DTE equipment or the modems will not link.

Creating and modifying global configuration templates 117

Page 118 of the Patton electronic 1001MC user manual — Notes on clock mode settings
Page 118 · click to enlarge
Page 118
  • internal-receiveRecover(0)
  • external-receiveRecover(1)

There are special situations which would require the use of the external-external(4) clock mode setting. This setting should only be used when the application has an IM2RC/K and a 1095RC in the rack system and a IM1/K and a 1095 standalone at the remote site. If you are using any other interface cards do not use the exter- nal-external(4) configuration.

Notes on framing mode settings The Framing Mode Setting notifies the card of the type of interface it will be connected to. When you are using an IM2RC/K with a 1095RC rack card, the system administrator should set the Local Clock Mode to external (either external-receiveRecover(1) or external-external(4)) and the Local Framing Mode to slotted. When you are using an IM1/K and a 1095 standalone at the remote site, the system administrator should set the Clock Mode to external-external(4) and the Remote Framing Mode to slotted.

Illegal configuration messages If you are receiving an invalid configuration indication after creating a configuration, it is resulting from an illegal combination of variables. In most cases, the cause of the problem has to do with the Framing Mode vari- able. Patton DSL modems should only be set to the slotted mode when you are using an IM2RC/K with the 1095RC or an IM1/K with the 1095 standalone unit. Also, if you are using a IM2RC/K or IM1/K interface card, the 1095/1095RC must always be set to the external clock mode. Review the table below for a list of valid configurations that can be used with the 1095/1095RC.

Local Clock Mode Local Framing Mode Remote Clock Mode Remote Framing Mode

Internal Normal Receive Recover Normal External Normal Receive Recover Normal

Externala Slotted Receive Recover Normal

Externala Slotted Externala

Slotted Receive Recover Normal Internal Normal Receive Recover Normal External Normal

a. Denotes a unit that must have an IM2RC/K or IM1/K installed.

Creating and modifying global configuration templates 118

Page 119 of the Patton electronic 1001MC user manual — Procedure for creating a template
Page 119 · click to enlarge
Page 119

Procedure for creating a template

Patton electronic 1001MC — Procedure for creating a template diagram (page 119)
Fig. 63 · Procedure for creating a template

Figure 58. Global Configuration Menu page

Do the following to create a template:

1. Click in the Model 1095 Configuration text box (see figure 58 ) and type a short name (10 characters or less) for the new template, then click the Create Configuration button.

The Model 1095 Global Configuration window displays (see figure 59).

Patton electronic 1001MC — Procedure for creating a template diagram (page 119)
Fig. 64 · Procedure for creating a template

Figure 59. Model 1095 Global Configuration page

Creating and modifying global configuration templates 119

Page 120 of the Patton electronic 1001MC user manual — Procedure for creating a template
Page 120 · click to enlarge
Page 120
2. Use the Local DTE Rate pop-up menu to select local DTE rate. You have the following choices:

– rate64k(3) – rate640k(12) – rate1280k(22) – rate1856k(32)

– rate128k(4) – rate704k(13) – rate1344k(23) – rate1920k(33)

– rate192k(5) – rate768k(14) – rate1408k(24) – rate1984k(34)

– rate256k(6) – rate832k(15) – rate1472k(25) – rate2048k(35)

– rate320k(7) – rate896k(16) – rate1536k(26) – rate2112k(36)

– rate384k(8) – rate960k(17) – rate1600k(28) – rate2176k(37)

– rate448k(9) – rate1024k(18) – rate1664k(29) – rate2240k(38)

– rate512k(10) – rate1088k(19) – rate1728k(30) – rate2304k(39)

– rate576k(11) – rate1216k(21) – rate1792k(31)

3. Use the Local Clock Mode (Local-Remote) pop-up menu to select the clock mode. You have the following choices:
4. Use the Local Tx Data Sample Point pop-up menu to select the local transmit data sample point. You have the following choices:
5. Use the Remote Tx Data Sample Point pop-up menu to select the remote transmit data sample point. You have the following choices:
6. Configure the Local TM from DTE pop-up menu using the following choices:
7. Configure the Remote TM from DTE pop-up menu using the following choices:
8. Configure the Local Framing Mode pop-up menu using the following choices:

Creating and modifying global configuration templates 120

Show 14 more labels / short text on this page
– internal-receiveRecover(0) · – external-receiveRecover(1) · – receiveRecover-internal(2) · – receiveRecover-external(3) · – external-external(4) · – normal(0) · – inverted(1) · – normal(0) · – inverted(1) · – disabled(0) · – enabled(1) · – disabled(0) · – enabled(1) · – slotted(0)
Page 121 of the Patton electronic 1001MC user manual — Modifying a template
Page 121 · click to enlarge
Page 121
9. Configure the Remote Framing Mode pop-up menu using the following choices:
10. When you have finished setting the configuration, click on the Submit button to save the changes.

Refer to section “Applying a template” on page 125 to activate the template.

Modifying a template This section describes how to modify a global configuration template. The Patton Model 1095 enables the Model 1001MC system administrator to configure the units for a wide variety of applications. Due to the many different applications that are supported, care must be taken when setting the configuration of your modems. There are several illegal combinations of variables that could cause problems with the modems if implemented incorrectly. Be sure to read the following information before creating a template:

  • Configuration rules—Things to keep in mind when creating a template (see section “Configuration rules” on page 121)
  • Notes on clock mode settings (see section “Notes on clock mode settings” on page 122)
  • Notes on framing mode settings (see section “Notes on framing mode settings” on page 122)
  • Illegal configuration messages (see section “Illegal configuration messages” on page 122)

After reviewing the rules and notes, go to section “Procedure for modifying a template” on page 123 to learn how to modify a template.

Configuration rules Keep in mind the following when modifying a template:

  • If you have an IM2RC/K G.703/G.704 Rear Card installed with a 1095RC in your rack, the unit must have the Local Clock Mode set to external and the Framing Mode set to slotted .
  • If you have an IM1/K G.703/G.704 Quick Connect Module installed with your 1095 at the remote site, the units must have the Clock Mode set to external-external and the Framing Mode for both the local and remote units must be set to slotted .
  • If you have any other interface connected to your 1095RC or your 1095 modems, the Framing Mode must be set to normal .
  • The system administrator should only set the Clock Mode to external-external(4) if there is an IM2RC/K installed in the 1095RC at the rack and an IM1/K installed in the 1095 standalone unit at the remote site.
  • When setting a unit for the external clock mode, the unit must have an external clock source in order to make a link. When using either an IM2RC/K or an IM1/K, the K module will always provide the external clock for

Creating and modifying global configuration templates 121

– normal(3) · – slotted(0) · – normal(3)

Page 122 of the Patton electronic 1001MC user manual — Notes on clock mode settings
Page 122 · click to enlarge
Page 122

the unit, so it is not necessary to have a G.703/G.704 link available. When using any other type of serial inter- face, make sure that an external clock is provided by the DTE equipment or the modems will not link.

  • internal-receiveRecover(0)
  • external-receiveRecover(1)

There are special situations which would require the use of the external-external(4) clock mode setting. This setting should only be used when the application has an IM2RC/K and a 1095RC in the rack system and a IM1/K and a 1095 standalone at the remote site. If you are using any other interface cards do not use the exter- nal-external(4) configuration.

Notes on framing mode settings The Framing Mode Setting notifies the card of the type of interface it will be connected to. When you are using an IM2RC/K with a 1095RC rack card, the system administrator should set the Local Clock Mode to external (either external-receiveRecover(1) or external-external(4)) and the Local Framing Mode to slotted. When you are using an IM1/K and a 1095 standalone at the remote site, the system administrator should set the Clock Mode to external-external(4) and the Remote Framing Mode to slotted.

Illegal configuration messages If you are receiving an invalid configuration indication after creating a configuration, it is resulting from an illegal combination of variables. In most cases, the cause of the problem has to do with the Framing Mode vari- able. Patton DSL modems should only be set to the slotted mode when you are using an IM2RC/K with the 1095RC or an IM1/K with the 1095 standalone unit. Also, if you are using a IM2RC/K or IM1/K interface card, the 1095/1095RC must always be set to the external clock mode. Review the table below for a list of valid configurations that can be used with the 1095/1095RC.

Local Clock Mode Local Framing Mode Remote Clock Mode Remote Framing Mode

Internal Normal Receive Recover Normal External Normal Receive Recover Normal

Externala Slotted Receive Recover Normal

Externala Slotted Externala

Slotted Receive Recover Normal Internal Normal Receive Recover Normal External Normal

a. Denotes a unit that must have an IM2RC/K or IM1/K installed.

Creating and modifying global configuration templates 122

Page 123 of the Patton electronic 1001MC user manual — Procedure for modifying a template
Page 123 · click to enlarge
Page 123

Procedure for modifying a template

Figure 60. Global Configuration Menu page

Do the following to modify a template:

1. Select a template from the Modify Configuration pop-up menu (see figure 58 ), then click the Modify Configuration button.

The Model 1095 Global Configuration window displays (see figure 59).

Figure 61. Model 1095 Global Configuration page

Creating and modifying global configuration templates 123

Page 124 of the Patton electronic 1001MC user manual — Procedure for modifying a template
Page 124 · click to enlarge
Page 124
2. Use the Local DTE Rate pop-up menu to select local DTE rate. You have the following choices:

– rate64k(3) – rate640k(12) – rate1280k(22) – rate1856k(32)

– rate128k(4) – rate704k(13) – rate1344k(23) – rate1920k(33)

– rate192k(5) – rate768k(14) – rate1408k(24) – rate1984k(34)

– rate256k(6) – rate832k(15) – rate1472k(25) – rate2048k(35)

– rate320k(7) – rate896k(16) – rate1536k(26) – rate2112k(36)

– rate384k(8) – rate960k(17) – rate1600k(28) – rate2176k(37)

– rate448k(9) – rate1024k(18) – rate1664k(29) – rate2240k(38)

– rate512k(10) – rate1088k(19) – rate1728k(30) – rate2304k(39)

– rate576k(11) – rate1216k(21) – rate1792k(31)

3. Use the Local Clock Mode (Local-Remote) pop-up menu to select the clock mode. You have the following choices:
4. Use the Local Tx Data Sample Point pop-up menu to select the local transmit data sample point. You have the following choices:
5. Use the Remote Tx Data Sample Point pop-up menu to select the remote transmit data sample point. You have the following choices:
6. Configure the Local TM from DTE pop-up menu using the following choices:
7. Configure the Remote TM from DTE pop-up menu using the following choices:
8. Configure the Local Framing Mode pop-up menu using the following choices:

Creating and modifying global configuration templates 124

Show 14 more labels / short text on this page
– internal-receiveRecover(0) · – external-receiveRecover(1) · – receiveRecover-internal(2) · – receiveRecover-external(3) · – external-external(4) · – normal(0) · – inverted(1) · – normal(0) · – inverted(1) · – disabled(0) · – enabled(1) · – disabled(0) · – enabled(1) · – slotted(0)
Page 125 of the Patton electronic 1001MC user manual — Deleting a template
Page 125 · click to enlarge
Page 125
9. Configure the Remote Framing Mode pop-up menu using the following choices:
10. When you have finished setting the configuration, click on the Submit button to save the changes.

Refer to section “Applying a template” on page 125 to activate the template.

Figure 62. Global Configuration Menu page

Deleting a template Do the following to delete a template:

1. Select a template from the Delete Configuration pop-up menu (see figure 62 ).
2. Click the Delete Configuration button.

Applying a template This section describes how to apply a global configuration to all Model 1095RC rack cards other than those that meet one of the following exceptions:

  • Model 1095RC rack cards installed in Model 1001 racks that have had the Rack Protection Mode option set to protected(1) will not be configured if a global template is applied (see section “Protecting a Model 1001 rack from global configuration” on page 114 for more information.

Creating and modifying global configuration templates 125

– normal(3) · – slotted(0) · – normal(3)

Page 126 of the Patton electronic 1001MC user manual — Configure all Model 1095RC rack cards in all Model 1001 racks
Page 126 · click to enlarge
Page 126
  • Model 1095RC rack cards that have had the Protected option set to protected(1) will not be configured if a global template is applied (see section “Protecting a Model 1095RC rack card from global configuration” on page 116 for more information.

Select the appropriate option from following configuration choices:

  • Globally configure all Model 1095RC rack cards in all Model 1001 racks (see section “Configure all Model 1095RC rack cards in all Model 1001 racks” on page 126)
  • Globally configure all Model 1095RC rack card in one Model 1001 rack (see section “Configure all Model 1095RC rack cards in one Model 1001 rack” on page 128)

Configure all Model 1095RC rack cards in all Model 1001 racks Do the following to apply global configuration to all Model 1095RC rack cards in all Model 1001 racks:

1. Starting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 63 . Figure 64 shows the web page navigation required to get to this area of the system.
Patton electronic 1001MC — Configure all Model 1095RC rack cards in all Model 1001 racks diagram (page 126)
Fig. 65 · Configure all Model 1095RC rack cards in all Model 1…

Figure 63. System Level Information page

Creating and modifying global configuration templates 126

Page 127 of the Patton electronic 1001MC user manual — Configure all Model 1095RC rack cards in all Model 1001 racks
Page 127 · click to enlarge
Page 127
Patton electronic 1001MC — Configure all Model 1095RC rack cards in all Model 1001 racks diagram (page 127)
Fig. 66 · Configure all Model 1095RC rack cards in all Model 1…

Figure 64. Web page navigation to System Level Information page

2. Use the Apply System Configuration pop-up menu (see figure 63 ) to select the template you want to apply.
3. Click the Apply Configuration button.

The template has been applied.

Creating and modifying global configuration templates 127

Page 128 of the Patton electronic 1001MC user manual — Configure all Model 1095RC rack cards in one Model 1001 rack
Page 128 · click to enlarge
Page 128

Configure all Model 1095RC rack cards in one Model 1001 rack Do the following to apply global configuration to all Model 1095RC rack cards installed in one Model 1001 rack:

1. Starting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 65 . Figure 64 on page 127 shows the web page navigation required to get to this area of the system.
Patton electronic 1001MC — Configure all Model 1095RC rack cards in one Model 1001 rack diagram (page 128)
Fig. 67 · Configure all Model 1095RC rack cards in one Model 1…

Figure 65. System Level Information page

2. Locate the rack section of the System Level Information page that you will configure (in figure 65 , Rack 1 Top Level is being modified).
3. Use the Apply Rack Configuration pop-up menu (see figure 65 ) to select the template you want to apply.
4. Click the Apply Configuration button.

The template has been applied.

Creating and modifying global configuration templates 128

Page 129 of the Patton electronic 1001MC user manual — Table of contents
Page 129 · click to enlarge
Page 129

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 130 of the Patton electronic 1001MC user manual — Table of contents
Page 130 · click to enlarge
Page 130

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 131 of the Patton electronic 1001MC user manual — Table of contents
Page 131 · click to enlarge
Page 131

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 132 of the Patton electronic 1001MC user manual — Configuration and management
Page 132 · click to enlarge
Page 132

Introduction

This chapter describes managing a Model 2701RC NetLink-G.703/G.704 network termination unit (NTU) using the Model 1001MC NetLink-NMS internal HTTP/HTML web engine and a standard web browser. This chapter is meant to be used in addition to the manual that came with your unit.

NetLink-NMS description Specifically designed for use in the Patton NetLink system, when the NetLink-G.703/G.704 NTU is coupled with the Model 1001MC NetLink-NMS and the Patton Model 1001 rack system, the modem is fully SNMP manageable. SNMP management can be performed on both the local and remote units using a standard SNMP network management station (NMS) or by using a standard web browser and the Model 1001MC's built-in web server. You can view and change configuration variables, view statistical variables, and view error and warning indications.

Configuration and management

This section describes the configuration and management of your NetLink G.703/G.704 NTUs using a Model 1001MC NetLink-NMS with built in HTTP/HTML web server. If you plan to manage your units using a standard network management station you can download the Patton Enterprise MIBs either through the SNMP web page on the Model 1001MC or obtain them from the Patton web site at www.patton.com.

The following pages are used to configure and manage the Model 2701RC:

  • Modem Information Rack X page: This page displays a list of the cards that are installed in your system and a quick view of any errors or warnings associated with your modems (see section “Displaying the Modem Information page” on page 133)
  • Model 2701 Configuration Slot X page: This page (along with the Model 2701 Configuration page) enables you to make configuration changes to the Model 2701RC and the remote CPE box (see section “Displaying the Model 2701RC Configuration Slot page” on page 135)
  • Model 2701 Configuration page: This page (along with the Model 2701 Configuration Slot page) enables you to update configuration of modems installed in the system (see “Displaying the Model 2701 Configuration page” on page 137)
  • Slot Configuration Page : This page can be used to set slot-specific information related to the system and how the system treats the slot in the case of errors or warnings (see section “Displaying the Model 2701RC Configuration Slot page” on page 135)

Introduction 132

Page 133 of the Patton electronic 1001MC user manual — Displaying the Modem Information page
Page 133 · click to enlarge
Page 133

Displaying the Modem Information page The Modem Information page (see figure 66) displays the cards installed in the system and a quick view of any errors or warnings associated with your modems.

Patton electronic 1001MC — Displaying the Modem Information page diagram (page 133)
Fig. 68 · Displaying the Modem Information page

Figure 66. Modem Information page for the Model 2701RC

Starting from the HOME page, to access the Modem Information Rack X page for the 2701RC, click on the fol- lowing links: Home (menu) > Configure Cards (menu) > View Rack [rack number]. Figure 67 on page 134 shows the web page navigation required to get to this area of the system. For more information about items on the Modem Information Rack X page, see “Displaying the Slot Configuration Page” on page 139.

Configuration and management 133

Page 134 of the Patton electronic 1001MC user manual — Displaying the Modem Information page
Page 134 · click to enlarge
Page 134
Patton electronic 1001MC — Displaying the Modem Information page diagram (page 134)
Fig. 69 · Displaying the Modem Information page

Figure 67. Web page navigation to Modem Information page

Configuration and management 134

Page 135 of the Patton electronic 1001MC user manual — Displaying the Model 2701RC Configuration Slot page
Page 135 · click to enlarge
Page 135

Displaying the Model 2701RC Configuration Slot page The Model 2701RC Configuration Slot page (see figure 68) enables you to make configuration changes to the Model 2701RC and the remote NTU. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Patton electronic 1001MC — Displaying the Model 2701RC Configuration Slot page diagram (page 135)
Fig. 70 · Displaying the Model 2701RC Configuration Slot page

Figure 68. Model 2701RC Configuration Slot page

Starting from the HOME page, to access the Model 2701RC Configuration Slot page for the 2701RC, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > model2701RC-xxx(x) (in the Local Model Code column) for the 2701RC you wish to manage (in the example shown in figure 68, the 2701RC was installed in slot 4). Figure 69 on page 136 shows the web page navigation required to get to this area of the system.

Configuration and management 135

Page 136 of the Patton electronic 1001MC user manual — Making configuration changes to your 2701RC NetLink NTU
Page 136 · click to enlarge
Page 136
Patton electronic 1001MC — Making configuration changes to your 2701RC NetLink NTU diagram (page 136)
Fig. 71 · Making configuration changes to your 2701RC NetLink…

Figure 69. Web page navigation to Model 2701RC Configuration Slot page

Making configuration changes to your 2701RC NetLink NTU Do use the following to make configuration changes to your NetLink NTU.

1. With the Model 2701 Configuration Slot page displayed, change the Input Mode (see figure 68 ) to superVisoryMode . The Modify Configuration hyperlink will appear.
2. Click on the Modify Configuration hyperlink to display the Model 2701RC Configuration page.
3. Make your configuration changes or select the Set Default Configuration button.
4. Select the Submit Query button to place the changes into the 1001MC’s temporary memory. If you decide that you do not want your changes implemented, you can select the Clear Changes button.
5. Select the Back hyperlink to return to the Model 2701 Configuration Slot page.
6. Change the Input Mode back to onLine and select the Submit Query button. When the unit returns to the online state, the 2701RC will begin implementing the configuration changes.

For more information about items on the Model 2701 Configuration Slot page, see “Model 2701RC Config- uration Slot X page MIB variables description” on page 143.

Configuration and management 136

Page 137 of the Patton electronic 1001MC user manual — Displaying the Model 2701 Configuration page
Page 137 · click to enlarge
Page 137

Displaying the Model 2701 Configuration page The Model 2701 Configuration page (see figure 70) enables you to make configuration changes to the Model 2701RC and the remote CPE box.

Patton electronic 1001MC — Displaying the Model 2701 Configuration page diagram (page 137)
Fig. 72 · Displaying the Model 2701 Configuration page

Figure 70. Model 2701 Configuration page

Starting from the HOME page, to access the Model 2701 Configuration page for the 2701RC, click on the fol- lowing links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > model2701RC-xxx(x) (in the Local Model Code column) for the 2701RC you wish to manage > Modify Configuration (you first have to change input mode from onLine to superVisoryMode. Figure 71 on page 138 shows the web page navigation required to get to this area of the system.

For more information about items on the Model 2701 Configuration page, see “Model 2701 Configuration page MIB variables description” on page 149.

Configuration and management 137

Page 138 of the Patton electronic 1001MC user manual — Displaying the Model 2701 Configuration page
Page 138 · click to enlarge
Page 138
Patton electronic 1001MC — Displaying the Model 2701 Configuration page diagram (page 138)
Fig. 73 · Displaying the Model 2701 Configuration page

Figure 71. Web page navigation to Model 2701 Configuration page

Configuration and management 138

Page 139 of the Patton electronic 1001MC user manual — Displaying the Slot Configuration Page
Page 139 · click to enlarge
Page 139

Displaying the Slot Configuration Page The Slot Configuration Page (see figure 72) is used to set slot-specific information related to the system and how the system treats that slot in the case of errors or warnings.

Patton electronic 1001MC — Displaying the Slot Configuration Page diagram (page 139)
Fig. 74 · Displaying the Slot Configuration Page

Figure 72. Slot Configuration Page

Starting from the HOME page, to access the Slot Configuration page for the 2701RC, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > X in the Card_Address column for the 2701RC you wish to manage (in the example shown in figure 72, the 2701RC was installed in slot 4). Figure 73 on page 140 shows the web page navigation required to get to this area of the system.

Configuration and management 139

Page 140 of the Patton electronic 1001MC user manual — Modem Information Rack X page MIB variables description
Page 140 · click to enlarge
Page 140
Patton electronic 1001MC — Modem Information Rack X page MIB variables description diagram (page 140)
Fig. 75 · Modem Information Rack X page MIB variables descript…

Figure 73. Web page navigation to Slot Configuration Page

For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description” on page 153.

Modem Information Rack X page MIB variables description

This section describes the MIB variables that are available on the Modem Information Rack X page. Starting from the HOME page, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number].

Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.

Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.

Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.

Rack Protection Mode (rackXProtected) If you want to protect all Model 2701RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the drop-down menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.

Modem Information Rack X page MIB variables description 140

Page 141 of the Patton electronic 1001MC user manual — Submit button
Page 141 · click to enlarge
Page 141

Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.

Power Supply 1 Status (rackXPower1Down) Displays the current status of power supply 1 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Power Supply 2 Status (rackXPower2Down) Displays the current status of power supply 2 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.

Card Address (nmsSlotID) This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the Model 1095 Configuration Slot page. This page can be used to set slot-specific information about the card.

Line Status (lineStatus) The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:

  • startup(1)
  • dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data.

Modem Information Rack X page MIB variables description 141

Page 142 of the Patton electronic 1001MC user manual — Warnings (warningCount)
Page 142 · click to enlarge
Page 142
  • testMode(3)

Warnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more infor- mation on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warning for the slot can be erased in the Slot Configuration page.

Errors (errorCount) This field displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page.

Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.

Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration page for the NetLink modem and its remote unit. The model code information is passed to the Model 1001MC after the card is placed online. The Model 1001MC is auto- sensing, meaning that when a card is found or lost, the information will automatically be updated in the sys- tem. You are not required to setup the Model Code information for each slot. When a card is removed from the system, the Model Code will be erased and an error or warning will be displayed for the slot (this depends on the settings in the Slot Configuration page)

Remote User Id (remoteUserID)

Remote Model Code (remoteModelCode)

Modem Information Rack X page MIB variables description 142

Page 143 of the Patton electronic 1001MC user manual — Model 2701RC Configuration Slot X page MIB variables description
Page 143 · click to enlarge
Page 143

Protected (disableGlobalConfig) You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed within the Configure Cards page or from the Slot Configuration page. After clicking the Sub- mit Query button to input the string to the management system, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards web page or from the Slot Configuration page.

Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Model 2701RC Configuration Slot X page MIB variables description

This section describes the MIB variables that are available on the Model 2701RC Configuration Slot X page. (See figure 68 on page 135). Starting from the HOME page, click on the following links: Home (menu) > Config- ure Cards (menu) > View Rack [rack number] > model2701RC-xxx(x) (in the Local Model Code column).

Model 2701RC Configuration Slot (nmsSlotID) Displays the address of the NetLink E1-G.703/G.704 NTU. The address is defined by the DIP-switch setting of S3 and S4 on the rack card.

Model 2701RC Configuration Slot X page MIB variables description 143

Page 144 of the Patton electronic 1001MC user manual — Line Status (lineStatus)
Page 144 · click to enlarge
Page 144

Line Status (lineStatus) Displays the status of the line. There are three possible values that can be displayed:

  • linedown(1)
  • dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data
  • testMode(3)

Alarm counters For the four alarm counters, you may choose to do numerous actions upon detecting errors: nothing, incre- ment the counter upon each occurrences of the error, send an SNMP trap, or send a Syslog message. The choice is determined by configuring the Line Down Indicator on the Slot Configuration Page. The following table clarifies what the parameter will do.

Send a Syslog message Increment the Alarm Counter

on the web page Send an SNMP trap

None ✔ Warning ✔ ✔ Error ✔ ✔ ✔

LOS (losAlarm) Displays the number of times Loss of Sync on the E1 line is detected. It is incremented when synchronization to the E1 stream is lost. This number is accumulating in the 1001MC.

  • none —Only Syslog message will be sent
  • warning —Syslog message will be sent beginning with “box\box.c: Warning:” and web page warning counter will be incremented
  • error —Syslog message will be sent beginning with “box\box.c: Error:”, the web page error counter will be incremented, and an SNMP trap message will be sent

Model 2701RC Configuration Slot X page MIB variables description 144

Page 145 of the Patton electronic 1001MC user manual — AIS (aisAlarm)
Page 145 · click to enlarge
Page 145

AIS (aisAlarm) Displays the number of times an Alarm Indication Signal on the E1 line is detected. This should be set when an unframed all ones code is received at RPOSI and RNEGI. This number is accumulating in the 1001MC.

  • none —Only Syslog message will be sent
  • warning —Syslog message will be sent beginning with “box\box.c: Warning:” and web page warning counter will be incremented
  • error —Syslog message will be sent beginning with “box\box.c: Error:”, the web page error counter will be incremented, and an SNMP trap message will be sent

Flap Count (lineDownCnt) Displays the number of times the E1 line has been up and then becomes down. This should be set when the E1 line is up and becomes down. This number is accumulating in the 1001MC.

  • none —Only Syslog message will be sent
  • warning —Syslog message will be sent beginning with “box\box.c: Warning:” and web page warning counter will be incremented
  • error —Syslog message will be sent beginning with “box\box.c: Error:”, the web page error counter will be incremented, and an SNMP trap message will be sent

CRC4 Error (crc4Error) Displays the number of CRC4 errors received by the E1 interface. This is an error counter that records word errors in the CRC4. The counter is disabled during loss of sync. This number is accumulating in the 1001MC.

  • none —Only Syslog message will be sent
  • warning —Syslog message will be sent beginning with “box\box.c: Warning:” and web page warning counter will be incremented
  • error —Syslog message will be sent beginning with “box\box.c: Error:”, the web page error counter will be incremented, and an SNMP trap message will be sent

The Clear Counter button This button clears all alarm counters.

Model 2701RC Configuration Slot X page MIB variables description 145

Page 146 of the Patton electronic 1001MC user manual — CRC4 Error Alarm Threshold (crc4Threshold)
Page 146 · click to enlarge
Page 146

CRC4 Error Alarm Threshold (crc4Threshold) The valid setting for the threshold is 0 to 255. By setting a threshold, the CRC4 Alarm counter will not issue the error/warning, Syslog, and SNMP Trap message unless the accumulating CRC4 Error Counter is greater than the threshold. The Record Current Configuration button will store the setting of the alarm threshold.

Input Mode (mode2701RC) The following settings are available:

  • onLine(0)
  • superVisoryMode(1)

To make configuration changes to the NetLink-E1 NTUs, you must first set this bit to superVisoryMode(1). When the Input Mode is set to superVisoryMode1), the Modify Configuration hyperlink will appear. Select the Modify Configuration hyperlink. The Model 2701 Configuration page will appear (see section “Model 2701 Configuration page MIB variables description” on page 149 for more information). After making config- uration changes to the NetLink-E1 NTUs in the Model 2701RC Configuration page, return to this page by clicking on the Back… hyperlink and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has completed and will cause it to copy the new configuration into the NetLink-E1 NTU configuration space. If this is not done, the NetLink-E1 NTU will not recognize the config- uration changes that were made.

Model 2701 Configuration Slot page Configuration Status table description The Configuration Status table shows the configuration for the set of units. There are columns for the local and remote units. If a field is highlighted in yellow, it signifies one of two possible conditions:

  • At start up, the Model 1001MC will display a default configuration for the card and all fields will be highlighted in yellow, notifying you that the information has not been verified. During the negotiation phase, the NetLink-E1 NTU modem will update the configuration in the Model 1001MC with its last set of stored parameters. As these fields are updated in the Model 1001MC, the yellow highlighting will disappear, signifying that the information has been updated. After the local and remote units are linked, the units will begin updating the remote information in the table, and Line Status set to datamode(2).
  • If a rack card is installed in the rack without a customer premise unit connected, the remote information will be left as either none or highlighted in yellow, notifying you that the information has not been verified.

The following sections define the MIB variables that are shown in the Configuration Status table.

Configuration Status (configStatus2701RC) This is the title of the status table and displays the configuration status of the rack card. The following status can be displayed:

  • Negotiating(0)—The 1001MC is receiving the rack card’s configuration for the first time
  • Static(1)—The 1001MC is showing the updated and correct configuration for the 2701RC
  • ImplementingChanges(2)—The 1001MC is updating configuration changes to the 2701RC.

Local Model Code (localModelCode/remoteModelCode) These variables display the local and remote models codes for the units that were found in the specified address.

Model 2701RC Configuration Slot X page MIB variables description 146

Page 147 of the Patton electronic 1001MC user manual — Line Format (lineFormat)
Page 147 · click to enlarge
Page 147

Line Format (lineFormat) The following status variables can be displayed:

  • unframe-G703(0)—Sets the line format to G.703 unframed
  • frame-G704(1)—Sets the line format to framed G.704

Clock Mode (clockMode2701RC) This variable defines the clock mode for the NetLink-E1 modems. The following status variables can be dis- played:

  • network-CLK(0)
  • internal-CLK(1)
  • external-CLK(2)

DTE Rate (dteRate2701RC) This variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of acti- vated channels.

Line Coding (lineCoding2701RC) The following status variables can be displayed:

  • AMI line coding
  • HDB3 line coding.

CRC4 Framing (crc) This displays if CRC-4 framing is enabled or disabled.

CAS Multiframing (casMF) This displays if CAS multiframing is enabled or disabled.

Line Build Out (lineBuildOut) This displays the selected line build out: either 75 ohm or 120 ohm.

Tx Clock Timing (txClock) This displays whether the serial transmit data coming from the DTE is clocked in using the DCE provided transmit clock or DTE provided external clock.

SW/HW Test Mode (testModeSetInd) This displays any test mode invoked from the toggle switches, DTE test mode lines, or from the web manage- ment page. This option will be highlighted in blue if the unit is in test mode. In the status of the parameter, SW means initiated via the web management page or HW means initiated from the toggle switches or DTE test mode interface signals on the remote standalone unit.

  • off(1)
  • pat(2)
  • pate(3)

Model 2701RC Configuration Slot X page MIB variables description 147

Page 148 of the Patton electronic 1001MC user manual — SW Test Mode (testModeSet2701RC)
Page 148 · click to enlarge
Page 148
  • lal(4)
  • lalWithpat(5)
  • lalWithpate(6)
  • rdl-v54(7)
  • rdl-v54Withpat(8)
  • rdl-v54Withpate(9)
  • rdl-csu(10)
  • rdl-csuWithpat(11)
  • rdl-csuWithpate(12)
  • rdl-remote(13)

SW Test Mode (testModeSet2701RC) This displays any test mode invoked through the NMS. See next configuration for information about invoking test modes through the NMS. This option will be highlighted in blue if the unit is in test mode.

  • off(1)-No test mode in process
  • pat(2)—Pattern generator (511) turned on
  • pate(3)—HPattern generator with errors (511/E) turned on
  • lal(4)—Local loopback test
  • lalWithpat(5)—Local loopback test with (511) pattern generator
  • lalWithpate(6)—Local loopback test with (511/E) pattern generator with errors
  • rdl-v54(7)—Remote loopback test from V54
  • rdl-Withpat(8)—Remote loopback test with 511 from V54
  • rdl-Withpate(9)—Remote loopback test with errors (511E) from V54

RDL Response (v54Loop) This displays if the unit will respond to a V.54 loop up command (enabled) or if the unit will ignore a V.54 loop up command (disabled).

FP Switches (frntSwitch) This displays if the front panel toggle switches used for loopbacks and pattern generators are enabled or disabled.

Pattern Select (patternSelect) This displays the pattern (511, 2047, QRSS) that is used when the pattern generator and detector are turned on.

Loop Time Out (loopTo) This displays the amount of time that the unit responding to a Remote Loop command will remain in test mode when the RL test mode is invoked. If the unit is not taken out of test mode by the menu within this time

Model 2701RC Configuration Slot X page MIB variables description 148

Page 149 of the Patton electronic 1001MC user manual — Model 2701 Configuration page MIB variables description
Page 149 · click to enlarge
Page 149

period, the unit will automatically time out and return to normal data mode. The timeout does not apply for loops selected via the front panel switches.

RDL type (rdlType) This displays the selected remote loopback type that will be used when initiating a remote loopback. The two loopback types are CSU and RDL.

Configuration Type (configType) This displays if the 2701RC is using the DIP switch control or software control for its configuration.

TM from DTE (testModeDTE) This displays if the 2701RC responds to the LL and RDL signals coming from the DTE.

Software Version (softVersion2701RC) This displays the software version of code in the 2701RC.

Reset button Software reset the E-carrier function card on its next poll from 1001MC.

Model 2701 Configuration page MIB variables description

The Model 2701 Configuration page enables you to update the configuration of the 2701RC NetLink-E1 NTU modems that are installed in the system. After making changes to the configuration on this page, select Back to return to the Model 2701 Configuration Slot page, then select onLine as the Input Mode, and finally, select Sub- mit Query to send the new information to the Model 1001MC over the network. Starting from the HOME page, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > model2701RC- xxx(x) (in the Local Model Code column) > change input mode to Supervisory > Modify Configuration.

The following sections describes the MIB variables that are available on the Model 2701 Configuration—Con- figuration page.

Line Status (lineStatus2701RC) This variable displays the status of the line. There are three possible values that can be displayed:

  • startup(1)
  • dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data
  • testMode(3)

Software Version (softVersion2701RC) This read-only MIB variable displays the current version of code that is running in the NetLink-E1 rack card modem.

Model 2701 Configuration page MIB variables description 149

Page 150 of the Patton electronic 1001MC user manual — Configuration Type (configType)
Page 150 · click to enlarge
Page 150

Configuration Type (configType) This displays if the 2701RC is using the DIP switch control or software control for its configuration.

Channel Assignment (dsoEnableCh1…dsoEnableCh31) If the 2701RC is operating in G.704 channelized mode, a configurable Channel Assignment table appears. When line format is set to frame-G704(1), individual channels can be either enabled(1) or disabled(0). These options cannot be accessed if line format is set to frame-G703(0).

Unit Configuration table This table shows the configurable MIB variables for the set of units. After changes are made, select the Submit Query button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model 2701 Configuration page.

The following sections explain the MIB variables that are shown in the Unit Configuration table.

Line Format (lineFormat) This option is used to set the line format to the following:

  • frame-G703(0)—G.703 unframed
  • frame-G704(1)—framed G.704

Clock Mode (clockMode2701RC) This variable defines the clock mode for the NetLink-E1 modems. The following options are available:

  • network-CLK(0)
  • internal-CLK(1)
  • external-CLK(2).

DTE Rate (dteRate2701RC) This read-only variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of activated channels.

Line Coding (lineCoding2701RC) This variable is used to select the G.703 line coding. The following options are available:

  • code-HDB3(0)—HDB3
  • code-AMI(1)—AMI

Model 2701 Configuration page MIB variables description 150

Page 151 of the Patton electronic 1001MC user manual — CRC4 Framing (crc)
Page 151 · click to enlarge
Page 151

CRC4 Framing (crc) This variable is used to enable or disable CRC-4 framing. The following options are available:

  • disable(0)
  • enable(1)

CAS Multiframing (casMF) This variable is used to enable or disable CAS multiframing. The following options are available:

  • disable(0)
  • enable(1)

Line Build Out (lineBuildOut) This is used to select the line build out. The following options are available:

  • lbo-75ohm(0)—75 ohm
  • lbo-120ohm(1)—120 ohm

Tx Clock Timing (txClock) The following options are available:

  • external(0)—serial transmit data coming from the DTE is clocked in using the DTE provided external clock
  • internal(1)—serial transmit data coming from the DTE is clocked in using the DCE provided transmit clock

H/W Test Mode (testModeSetInd) This read-only variable displays any test mode invoked from the toggle switches and DTE test mode lines. If the unit is in a test mode, this option will be highlighted in blue.

  • off(1)
  • pat(2)
  • pate(3)
  • lal(4)
  • lalWithpat(5)
  • lalWithpate(6)
  • rdl-v54(7)
  • rdl-v54Withpat(8)
  • rdl-v54Withpate(9)
  • rdl-csu(10)
  • rdl-csuWithpat(11)

Model 2701 Configuration page MIB variables description 151

Page 152 of the Patton electronic 1001MC user manual — Software Test Mode (testModeSet2701RC)
Page 152 · click to enlarge
Page 152
  • rdl-csuWithpate(12)
  • rdl-remote(13)

Software Test Mode (testModeSet2701RC) This is used to invoke test modes through the NMS. Available options are:

  • off(1)-No test mode in process
  • pat(2)—Pattern generator (511) turned on
  • pate(3)—HPattern generator with errors (511/E) turned on
  • lal(4)—Local loopback test
  • lalWithpat(5)—Local loopback test with (511) pattern generator
  • lalWithpate(6)—Local loopback test with (511/E) pattern generator with errors
  • rdl(7)—Remote loopback test from V54
  • rdl-Withpat(8)—Remote loopback test with 511 from V54
  • rdl-Withpate(9)—Remote loopback test with errors (511E) from V54

RDL Response(v54Loop) The following options are available:

  • enabled(1)—The unit will respond to a V.54 loop up command
  • disabled(0)—The unit will ignore a V.54 loop up command

FP Switches (frntSwitch) This selects if the front panel toggle switches used for loopbacks and pattern generators are:

  • enabled(1)
  • disabled(0).

Pattern Select (patternSelect) The following options are available:

  • qrss(0)—QRSS is the pattern that is used when the pattern generator and detector are turned on
  • five11(1)—511 is the pattern that is used when the pattern generator and detector are turned on
  • two047(2)—2047 is the pattern that is used when the pattern generator and detector are turned on

Loop Timeout (loopTo) This selects the amount of time that the unit will remain in test mode when the remote test mode is invoked. If the responding unit is not taken out of test mode within this time period, the unit will automatically time out and return to normal data mode.

Model 2701 Configuration page MIB variables description 152

Page 153 of the Patton electronic 1001MC user manual — Slot Configuration page MIB variables description
Page 153 · click to enlarge
Page 153

RDL Type (rdlType) This displays the selected remote loopback type that will be used when initiating a remote loopback. Available options are:

  • csu(1)
  • v54(2)

Config Type (configType) The following options are available:

  • switch-config(0)—The 2701RC is using the DIP switch control for its configuration
  • software-config(1)—The 2701RC is using the software control for its configuration

Test Mode from DTE (testModeDTE) When enabled, the 2701RC will respond to LL and RDL signals coming from the DTE.

Slot Configuration page MIB variables description

This section describes the MIB variables that are available on the Slot Configuration page. From the Modem Infor- mation page, the address column creates a list of hyperlinks to the Slot Configuration page associated with the spec- ified address. The Slot Configuration page can be used to set slot-specific information related to the system and how the system treats the slot in the case of errors and warning. Starting from the HOME page, click on the follow- ing links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > X (in the Card Address column).

Card Address (nmsSlotID) Displays the address of the card.

Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.

View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).

Local User Id (localUserID) User supplied string that defines the NetLink NTU installed in the rack. The string is stored in non-volatile flash within the NetLink NTU and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within this page.

Slot Configuration page MIB variables description 153

Card Identification Information

Page 154 of the Patton electronic 1001MC user manual — Remote User Id (remoteUserID)
Page 154 · click to enlarge
Page 154

Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non- volatile flash within the CP unit. If the unit is moved, the User ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within this page.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.

Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warning) associated with the specified slot.

Hardware Reset (resetStatus) Selecting this push button will force the associated modem to perform a hardware reset.

Card Lost Indication (cardLostIndication) This variable allows you to choose what type of indication will be made if a modem is removed from the man- agement system. Three choices are available:

  • None(0)
  • Warning(1)
  • Error(2)

Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. Three choices are available:

  • None(0)
  • Warning(1)
  • Error(2)

Slot Configuration page MIB variables description 154

Alarm Information

Page 155 of the Patton electronic 1001MC user manual — Creating and modifying global configuration templates
Page 155 · click to enlarge
Page 155

Creating and modifying global configuration templates

Model 2701RC rack cards can be configured globally by templates you create. If you use this capability, you have the option to globally configure some or all Model 2701RC NTUs in multiple racks, or those in just one rack.

This section contains the following information to help you configure and use templates:

  • Protecting individual Model 1001 racks and 2701RC rack cards from global modification—You may not want all racks or NTUs to be modified when you apply the global template, so section “Protecting Model 1001 racks and Model 2701RC NTUs from global modification” describes how to protect individual 1001 racks and 2701RC NTUs from being globally configured.
  • Creating a template (see section “Creating a template” on page 158)
  • Modifying a template (see section “Modifying a template” on page 163)
  • Deleting a template (see section “Deleting a template” on page 164)
  • Applying a template (see section “Applying a template” on page 164)

Protecting Model 1001 racks and Model 2701RC NTUs from global modification This section describes how to protect 1001 racks and 2701RC NTU cards from being modified when a global modification is applied. This is useful if you are setting all but a few cards to the same configuration. You may protect an entire rack or only selected individual rack cards.

  • To protect an entire Model 1001 rack, see the section “Protecting an entire Model 1001 rack from global configuration” on page ….
  • To protect a selected Model 2701RC rack card, see section “Protecting a Model 2701RC rack card from global configuration” on page ….

Protecting an entire Model 1001 rack from global configuration Do the following to protect a Model 1001 rack:

Creating and modifying global configuration templates 155

Page 156 of the Patton electronic 1001MC user manual — Creating and modifying global configuration templates
Page 156 · click to enlarge
Page 156
1. Starting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 74 .
Patton electronic 1001MC — Creating and modifying global configuration templates diagram (page 156)
Fig. 76 · Creating and modifying global configuration template…

Figure 74. System Level Information page

2. Use the Rack Protection Mode pop-up menu (see figure 74 ) to select protected(1).

Creating and modifying global configuration templates 156

Page 157 of the Patton electronic 1001MC user manual — Protecting a selected Model 2701RC rack card from global configuration
Page 157 · click to enlarge
Page 157
3. Click the Apply Protection button.

The rack is now protected.

Protecting a selected Model 2701RC rack card from global configuration Do the following to protect a single Model 2701RC rack card:

1. Starting from the HOME page, click on the following links: Configure Cards > View Rack 1 (choose the rack you want to protect, in the example shown in figure 75 , rack 1 was selected). Figure 75 shows the web page navigation required to get to this area of the system.

Figure 75. NTU Information Rack 1 page

2. Locate the card address (see figure 55 on page 119) of the Model 2701RC you want to protect.
3. Set the Protected pop-up menu (see figure 55 on page 119) to protected(1).
4. Click the Submit button.

The rack card is now protected.

Creating and modifying global configuration templates 157

Page 158 of the Patton electronic 1001MC user manual — Creating a template
Page 158 · click to enlarge
Page 158

Creating a template This section describes how to create a global configuration template.

Patton electronic 1001MC — Creating a template diagram (page 158)
Fig. 77 · Creating a template

Figure 76. Global Configuration Menu page

Do the following to create a template:

1. In the Create New Configuration section, type a short name (10 characters or less) in the text box named Model 2701RC/2707RC Configuration: ( see figure 76 ). Clicking on the Create Configuration button, creates the new template and displays the Model 2701RC Global Configuration window with two parts.

Creating and modifying global configuration templates 158

Page 159 of the Patton electronic 1001MC user manual — Creating a template
Page 159 · click to enlarge
Page 159

The first table is the Channel Assignment section for activating the DS0 time slots you need (see figure 77). The two options for each channel are:

Patton electronic 1001MC — Creating a template diagram (page 159)
Fig. 78 · Creating a template

Figure 77. Channel Assignment table

Creating and modifying global configuration templates 159

– Active(0) · – Inactive(1)

Page 160 of the Patton electronic 1001MC user manual — Creating a template
Page 160 · click to enlarge
Page 160

The second part is the Unit Configuration section (see figure 78) for the configuration of the E1 link parame- ters. There are 16 configurable parameters. What follows is a description of them with the available options for each.

Patton electronic 1001MC — Creating a template diagram (page 160)
Fig. 79 · Creating a template

Figure 78. Unit Configuration section of the web management table

  • Line Format

- frame-G703(0)—This is called either Clear Channel or Transparent mode. The DTE Rate is always

2.408 Mbps and the Channel Assignment table does not affect the configuration when this option is cho- sen.

- frame-G704(1)—This is channelized mode. When selected, the Channel Assignment table directly

determines the DTE Rate.

  • DTE Rate

– There are no configurable options for this parameter, however it is affected by two configurable parame-

ters: the Line Format and the Channel Assignment table.

  • CRC Framing—Is applicable when the “frame-G704(1)” Line Format is chosen.
  • Line Build Out—This selects the electrical characteristics for the types of electrical connections, un-balanced 75-Ohm coaxial cable or balanced 120-Ohm twisted pair cable.

- lbo-75Ohm(0), when using dual coaxial connections

- lbo-120Ohm(1), when using twisted pair as the transmission medium

  • V54 Loop, enables or disables the 2701RC’s ability to respond to a V.54 remote loop initiation pattern
  • Pattern Loop

Creating and modifying global configuration templates 160

Show 4 more labels / short text on this page
- disabled(0) · - enabled(1) · - disabled(0) · - enabled(1)
Page 161 of the Patton electronic 1001MC user manual — Creating a template
Page 161 · click to enlarge
Page 161

- five11(1)—The 511-bit length pseudo-random test pattern

- two047(2)—The 2047-bit length pseudo-random test pattern

  • Loop Timeout, determines the length of the in-band loop test. If the test is not of indefinite length, it will automatically terminate the loop session.

- no-time-out(9)—the loop runs indefinitely and must be turned off manually by the user.

  • Config Type

- Switch-config(0)—The 2701RC gets its configuration from the DIP switches on the card

- Software-config(1)—The 2701RC gets its configuration via the software configuration and not the DIP

switches.

  • Clock Mode, this selects the source of the clock used for the Transmit signal on the E1 channel. Please note the difference from “Tx Clock Timing” described below.

- network-CLK(0)—derived from the received signal from the network

- internal-CLK(1)—driven by the internal oscillator in the 2701RC NTU

- external-CLK(2)—provided by DTE External Transmit Clock signal

  • Line Coding, the two commonly used types of line coding on E1 circuits

- code-AMI(1)—primarily in legacy equipment

  • CAS Multi Framing, refers to an E1 circuit which is using bit-oriented signaling in the multi-frame made of 16 x 256-bit frames

Creating and modifying global configuration templates 161

Show 13 more labels / short text on this page
- qrss(0)—Quasi-random-signal-source · - time-out-5min(0)—5 minutes · - time-out-10min(1)—10 minutes · - time-out-15min(2)—15 minutes · - time-out-30min(3)—30 minutes · - time-out-45min(4)—45 minutes · - time-out-60min(5)—60 minutes · - time-out-90min(6)—90 minutes · - time-out-120min(7)—120 minutes · - time-out-180min(8)—180 minutes · - code-HDB3(0)—most common · - Disabled(0) · - Enabled(1)
Page 162 of the Patton electronic 1001MC user manual — Creating a template
Page 162 · click to enlarge
Page 162
  • Tx Clock Timing, this selects the source of the DTE Transmit Clock signal. Note that Clock Mode above is for the transmitted E1 signal.

- external(0)—Use only when the Clock Mode is set to external-CLK(2).

- internal(1)—Use when the Clock Mode is set to either internal-CLK(1) or networtk-CLK(0).

  • FP Switch (Front Panel

- disabled (0)—disables the toggle switches on the front panel of the 2701RC rack card

- enabled(1)—enables the ability to use the front panel toggle switches

  • In Band Loops, the two in-band loops are the CSU loop and the V.54 loop.

- disabled(0)—neither loop can be enabled.

- enabled(1)—one of the in-band loops can be enabled depending on the selection of the RDL Type.

  • RDL Type

- csu(1)—Selects the in-band loop which is initiated as the standard CSU loopback.

- v54(2)—functions as defined by the V.54 remote Loopback.

  • Test Mode DTE, refers to the initiation of loopbacks via one of the DTE signals.

- disabled(0)—no loopbacks can be initiated by a DTE signal

- enabled(1)—Loopbacks can be initiated by a DTE signal.

Refer to section “Applying a template” on page 164 to activate the template.

Creating and modifying global configuration templates 162

Page 163 of the Patton electronic 1001MC user manual — Modifying a template
Page 163 · click to enlarge
Page 163

Modifying a template This section describes how to modify a global configuration template.

Patton electronic 1001MC — Modifying a template diagram (page 163)
Fig. 80 · Modifying a template

Figure 79. Global Configuration Menu page

Do the following to modify a template:

1. Select a template from the Modify Configuration pop-up menu (see figure 79 ), then click the Modify Configuration button.

Creating and modifying global configuration templates 163

Page 164 of the Patton electronic 1001MC user manual — Deleting a template
Page 164 · click to enlarge
Page 164
Patton electronic 1001MC — Deleting a template diagram (page 164)
Fig. 81 · Deleting a template

Figure 80. Model 2701RC Global Configuration page

2. Change the parameters requiring modification (see figure 80 ). When you have finished changing the configuration, click on the Submit button to save the changes.

Refer to section “Applying a template” on page 164 to activate the template.

Deleting a template Do the following to delete a template:

1. Select a template from the Delete Configuration pop-up menu (see figure 79 on page 163).
2. Click the Delete Configuration button.

Applying a template This section describes how to apply a global configuration to all Model 2701RC rack cards. Model 2701RC cards which will not be configured to the selected Global Configuration are:

  • Those installed in a Model 1001 rack that has the entire rack set to be protected(1)
  • Those that are individually set to protected(1) mode

Instructions for protecting either an entire rack or individual 2701RC cards are given earlier in this chapter.

Creating and modifying global configuration templates 164

Page 165 of the Patton electronic 1001MC user manual — To configure all Model 2701RC rack cards in all Model 1001 racks
Page 165 · click to enlarge
Page 165

The template can be applied to:

  • All 2701RC NTUs in ALL Model 1001 racks
  • All 2701RC NTUs in just ONE Model 1001 rack

To configure all Model 2701RC rack cards in all Model 1001 racks Complete the following steps.

1. Starting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 81 .
Patton electronic 1001MC — To configure all Model 2701RC rack cards in all Model 1001 racks diagram (page 165)
Fig. 82 · To configure all Model 2701RC rack cards in all Mode…

Figure 81. System Level Information page—System Overview section

2. Use the Apply 2701Rc System Configuration pop-up menu (see figure 81 ) to select the template you want to apply.
3. Click the Apply Configuration button.

The template has been applied.

Creating and modifying global configuration templates 165

Page 166 of the Patton electronic 1001MC user manual — To configure all Model 2701RC rack cards in just one Model 1001 rack
Page 166 · click to enlarge
Page 166

To configure all Model 2701RC rack cards in just one Model 1001 rack Complete the following steps:

1. Starting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 82 .
Patton electronic 1001MC — To configure all Model 2701RC rack cards in just one Model 1001 rack diagram (page 166)
Fig. 83 · To configure all Model 2701RC rack cards in just one…

Figure 82. System Level Information page—Rack section

2. Locate the rack section of the System Level Information page that you will configure (in figure 82 , Rack 1Top Level is being modified).
3. Use the Apply Rack Configuration pop-up menu (see figure 82 ) to select the template you want to apply.
4. Click the Apply Configuration button.

The template has been applied.

Creating and modifying global configuration templates 166

Page 167 of the Patton electronic 1001MC user manual — Table of contents
Page 167 · click to enlarge
Page 167

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 168 of the Patton electronic 1001MC user manual — Table of contents
Page 168 · click to enlarge
Page 168

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 169 of the Patton electronic 1001MC user manual — Configuration and management
Page 169 · click to enlarge
Page 169

Introduction

This chapter describes managing a Model 2707RC NetLink-G.703 network termination unit (NTU) using the Model 1001MC NetLink-NMS internal HTTP/HTML web engine and a standard web browser. This chapter is meant to be used in addition to the manual that came with your unit.

NetLink-NMS description Specifically designed for use in the Patton NetLink system, when the NetLink-G.703 NTU is coupled with the Model 1001MC NetLink-NMS and the Patton Model 1001 rack system, the modem is fully SNMP manageable. SNMP management can be performed on both the local and remote units using a standard SNMP network man- agement station (NMS) or by using a standard web browser and the Model 1001MC's built-in web server. You can view and change configuration variables, view statistical variables, and view error and warning indications.

Configuration and management

This section describes the configuration and management of your NetLink G.703 NTUs using a Model 1001MC NetLink-NMS with built in HTTP/HTML web server. If you plan to manage your units using a standard network management station you can download the Patton Enterprise MIBs either through the SNMP web page on the Model 1001MC or obtain them from the Patton web site at www.patton.com.

The following pages are used to configure and manage the Model 2707RC:

  • Modem Information Rack X page: This page displays a list of the cards that are installed in your system and a quick view of any errors or warnings associated with your modems (see section “Displaying the Modem Information page” on page 170)
  • Model 2707RC Configuration Slot page: This page (along with the Model 2707RC Configuration—Configuration page) enables you to make configuration changes to the Model 2707RC and the remote CPE box (see section “Displaying the Model 2707RC Configuration Slot page” on page 172)
  • Model 2707RC Configuration—Next Configuration page: This page (along with the Model 2707RC Configuration Slot page) enables you to update configuration of modems installed in the system (see “Displaying the Model 2707RC Configuration—Configuration page” on page 174)
  • Slot Configuration page: This page can be used to set slot-specific information related to the system and how the system treats the slot in the case of errors or warnings (see section “Displaying the Model 2707RC Configuration Slot page” on page 172)

Introduction 169

Page 170 of the Patton electronic 1001MC user manual — Displaying the Modem Information page
Page 170 · click to enlarge
Page 170

Displaying the Modem Information page The Modem Information page (see figure 83) displays the cards installed in the system and a quick view of any errors or warnings associated with your modems.

Patton electronic 1001MC — Displaying the Modem Information page diagram (page 170)
Fig. 84 · Displaying the Modem Information page

Figure 83. Modem Information page for the Model 2707RC

Starting from the HOME page, to access the Modem Information page for the 2707RC, click on the following links: Configure Cards > View Rack 1. Figure 84 on page 171 shows the web page navigation required to get to this area of the system. For more information about items on the Modem Information page, see “Displaying the Slot Configuration page” on page 176.

Configuration and management 170

Page 171 of the Patton electronic 1001MC user manual — Displaying the Modem Information page
Page 171 · click to enlarge
Page 171
Patton electronic 1001MC — Displaying the Modem Information page diagram (page 171)
Fig. 85 · Displaying the Modem Information page

Figure 84. Web page navigation to Modem Information page

Configuration and management 171

Page 172 of the Patton electronic 1001MC user manual — Displaying the Model 2707RC Configuration Slot page
Page 172 · click to enlarge
Page 172

Displaying the Model 2707RC Configuration Slot page The Model 2707RC Configuration Slot page (see figure 85) enables you to make configuration changes to the Model 2707RC and the remote NTU. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Patton electronic 1001MC — Displaying the Model 2707RC Configuration Slot page diagram (page 172)
Fig. 86 · Displaying the Model 2707RC Configuration Slot page

Figure 85. Model 2707RC Configuration Slot page

Starting from the HOME page, to access the Model 2707RC Configuration Slot page for the 2707RC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 2707RC you wish to manage (in the example shown in figure 85, the 2707RC was installed in slot 1). Figure 86 on page 173 shows the web page navigation required to get to this area of the system.

Configuration and management 172

Page 173 of the Patton electronic 1001MC user manual — Making configuration changes to your 2707RC NetLink NTU
Page 173 · click to enlarge
Page 173
Patton electronic 1001MC — Making configuration changes to your 2707RC NetLink NTU diagram (page 173)
Fig. 87 · Making configuration changes to your 2707RC NetLink…

Figure 86. Web page navigation to Model 2707RC Configuration Slot page

Making configuration changes to your 2707RC NetLink NTU Do use the following to make configuration changes to your NetLink NTU.

1. With the Model 2707RC Configuration Slot page displayed, change the Input Mode (see figure 85 ) to superVisoryMode . The Modify Configuration hyperlink will appear.
2. Click on the Modify Configuration hyperlink to display the Model 2707RC Configuration page.
3. Make your configuration changes or select the Set Default Configuration button.
4. Select the Submit Query button to place the changes into the 1001MC’s temporary memory. If you decide that you do not want your changes implemented, you can select the Clear Changes button.
5. Select the Back hyperlink to return to the Model 2707RC Configuration Slot page.
6. Change the Input Mode back to onLine and select the Submit Query button. When the unit returns to the online state, the 2707RC will begin implementing the configuration changes.

For more information about items on the Model 2707RC Configuration Slot page, see “Model 2707RC Con- figuration Slot page MIB variables description” on page 181.

Configuration and management 173

Page 174 of the Patton electronic 1001MC user manual — Displaying the Model 2707RC Configuration—Configuration page
Page 174 · click to enlarge
Page 174

Displaying the Model 2707RC Configuration—Configuration page The Model 2707RC Configuration—Configuration page (see figure 87) enables you to make configuration changes to the Model 2707RC and the remote CPE box. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Patton electronic 1001MC — Displaying the Model 2707RC Configuration—Configuration page diagram (page 174)
Fig. 88 · Displaying the Model 2707RC Configuration—Configurat…

Figure 87. Model 2707RC Configuration—Configuration page

Starting from the HOME page, to access the Model 2707RC Configuration—Configuration page for the 2707RC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 2707RC you wish to manage > Modify Configuration (you first have to change input mode from onLine to superVisoryMode. Figure 88 on page 175 shows the web page navigation required to get to this area of the system.

For more information about items on the Model 2707RC Configuration—Configuration page, see “Model 2707RC Configuration—Configuration page MIB variables description” on page 183.

Configuration and management 174

Page 175 of the Patton electronic 1001MC user manual — Displaying the Model 2707RC Configuration—Configuration page
Page 175 · click to enlarge
Page 175
Patton electronic 1001MC — Displaying the Model 2707RC Configuration—Configuration page diagram (page 175)
Fig. 89 · Displaying the Model 2707RC Configuration—Configurat…

Figure 88. Web page navigation to Model 2707RC Configuration—Next Configuration page

Configuration and management 175

Page 176 of the Patton electronic 1001MC user manual — Displaying the Slot Configuration page
Page 176 · click to enlarge
Page 176

Displaying the Slot Configuration page The Slot Configuration page (see figure 89) is used to set slot-specific information related to the system and how the system treats that slot in the case of errors or warnings.

Patton electronic 1001MC — Displaying the Slot Configuration page diagram (page 176)
Fig. 90 · Displaying the Slot Configuration page

Figure 89. Slot Configuration page

Starting from the HOME page, to access the Slot Configuration page for the 2707RC, click on the following links: Configure Cards > View Rack 1 > Card_Address for the 2707RC you wish to manage (in the example shown in figure 89, the 2707RC was installed in slot 1). Figure 90 on page 177 shows the web page navigation required to get to this area of the system.

Configuration and management 176

Page 177 of the Patton electronic 1001MC user manual — Modem Information page MIB variables description
Page 177 · click to enlarge
Page 177
Patton electronic 1001MC — Modem Information page MIB variables description diagram (page 177)
Fig. 91 · Modem Information page MIB variables description

Figure 90. Web page navigation to Slot Configuration page

For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description” on page 185.

Modem Information page MIB variables description

This section describes the MIB variables that are available on the Modem Information page.

Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.

Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.

Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.

Rack Protection Mode If you want to protect all Model 2707RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the pop-up menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.

Modem Information page MIB variables description 177

Page 178 of the Patton electronic 1001MC user manual — Submit button
Page 178 · click to enlarge
Page 178

Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.

Power Supply 1 Status Displays the current status of power supply 1 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Power Supply 2 Status Displays the current status of power supply 2 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.

Card Address (nmsSlotID) This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the Model 2707RC Configuration Slot page. This page can be used to set slot-specific information about the card.

Line Status The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:

  • startup(1)
  • dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data.
  • testMode(3)

Modem Information page MIB variables description 178

Page 179 of the Patton electronic 1001MC user manual — Warnings (warningCount)
Page 179 · click to enlarge
Page 179

Warnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more infor- mation on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warning for the slot can be erased in the Slot Configuration page.

Errors (errorCount) This field displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page.

Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.

Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration page for the NetLink modem and its remote unit. The model code information is passed to the Model 1001MC after the card is placed online. The Model 1001MC is auto- sensing, meaning that when a card is found or lost, the information will automatically be updated in the sys- tem. You are not required to setup the Model Code information for each slot. When a card is removed from the system, the Model Code will be erased and an error or warning will be displayed for the slot (this depends on the settings in the Slot Configuration page)

Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, you ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.

Remote Model Code (remoteModelCode) This column displays the model code of the Customer Premise NetLink modem at the far end of the link. This information is communicated from the CP box over the link to the CO Rack Card unit. The NetLink mDSL

Modem Information page MIB variables description 179

Page 180 of the Patton electronic 1001MC user manual — Protected
Page 180 · click to enlarge
Page 180

rack card will then update the Model 1001MC. For this reason this information will not be available until after the link is made between the two modems.

Protected You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed within the Configure Cards page or from the Slot Configuration page. After clicking the Sub- mit Query button to input the string to the management system, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards web page or from the Slot Configuration page.

Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Modem Information page MIB variables description 180

Page 181 of the Patton electronic 1001MC user manual — Model 2707RC Configuration Slot page MIB variables description
Page 181 · click to enlarge
Page 181

Model 2707RC Configuration Slot page MIB variables description

This section describes the MIB variables that are available on the Model 2707RC Configuration Slot page.

Model 2707RC Configuration Slot (nmsSlotID) Displays the address of the NetLink E1-G.703 NTU. The address is defined by the DIP-switch setting of S3 and S4 on the rack card.

Line Status (lineStatus) Displays the status of the line. There are three possible values that can be displayed:

  • linedown(1)
  • dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data
  • testMode(3)

Input Mode (mode2707RC) The following settings are available:

  • onLine(0)
  • superVisoryMode(1)

To make configuration changes to the NetLink-E1 NTUs, you must first set this bit to superVisoryMode(1). When the Input Mode is set to superVisoryMode(1), the Modify Configuration hyperlink will appear on the web page next to the Refresh Current Page hyperlink. Select the Modify Configuration hyperlink. The Model 2707RC Configuration—Configuration page will appear (see section “Model 2707RC Configuration—Con- figuration page MIB variables description” on page 183 for more information). After making configuration changes to the NetLink-E1 NTUs in the Model 2707RC Configuration page, return to this page and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has com- pleted and will cause it to copy the new configuration into the NetLink-E1 NTU configuration space. If this is not done, the NetLink-E1 NTU will not recognize the configuration changes that were made.

Model 2707RC Configuration Slot X page Configuration Status table description The Configuration Status table shows the configuration for the 2707RC card. If a field is highlighted in yellow, it signifies one of two possible conditions:

  • At start up, the Model 1001MC will display a default configuration for the card and all fields will be highlighted in yellow, notifying you that the information has not been verified. During the negotiation phase, the NetLink-E1 NTU modem will update the configuration in the Model 1001MC with its last set of stored parameters. As these fields are updated in the Model 1001MC, the yellow highlighting will disappear, signifying that the information has been updated. After the local and remote units are linked, the units will begin updating the remote information in the table, and Line Status set to datamode(2).
  • If a rack card is installed in the rack without a customer premise unit connected, the remote information will be left as either none or highlighted in yellow, notifying you that the information has not been verified.

The following sections define the MIB variables that are shown in the Configuration Status table.

Model 2707RC Configuration Slot page MIB variables description 181

Page 182 of the Patton electronic 1001MC user manual — Configuration Status (configStatus2707RC)
Page 182 · click to enlarge
Page 182

Configuration Status (configStatus2707RC) Displays the configuration status of the rack card. The following status can be displayed:

  • Negotiating(0)—The 1001MC is receiving the rack card’s configuration for the first time
  • Static(1)—The 1001MC is showing the updated and correct configuration for the 2707RC
  • ImplementingChanges(2)—The 1001MC is updating configuration changes to the 2707RC.

Model Code (localModelCode/remoteModelCode) These variables display the local and remote models codes for the units that were found in the specified address.

Line Format (lineFormat) The following status variable can be displayed:

  • unframe-G703(0)—Sets the line format to G.703 unframed

Clock Mode (clockMode2707RC) This variable defines the clock mode for the NetLink-E1 modems. The following status variables can be dis- played:

  • network-CLK(0)
  • internal-CLK(1)
  • external-CLK(2)

DTE rate (dteRate2707RC) This variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of acti- vated channels.

Line Coding (lineCoding2707RC) The following status variables can be displayed:

  • AMI line coding
  • HDB3 line coding.

Line Build Out (lineBuildOut) This displays the selected line build out: either 75 ohm or 120 ohm.

FP Switches (frntSwitch) This displays if the front panel toggle switches used for loopbacks and pattern generators are enabled or disabled.

H/W Test mode (testModeSetInd) This displays any test mode invoked from the toggle switches and DTE test mode lines. This option will be highlighted in blue if the unit is in test mode.

S/W Test mode (testModeSet2707RC) This displays any test mode invoked through the NMS. See next configuration for information about invoking test modes through the NMS. This option will be highlighted in blue if the unit is in test mode.

Model 2707RC Configuration Slot page MIB variables description 182

Page 183 of the Patton electronic 1001MC user manual — Model 2707RC Configuration—Configuration page MIB variables description
Page 183 · click to enlarge
Page 183

Loop Time Out (loopTo) This displays the amount of time that the unit responding to a Remote Loop command will remain in test mode when the RL test mode is invoked. If the unit is not taken out of test mode by the menu within this time period, the unit will automatically time out and return to normal data mode. The timeout does not apply for loops selected via the front panel switches.

TM from DTE (testModeDTE) This displays if the 2707RC responds to the LL and RDL signals coming from the DTE.

Configuration Type (configType) This displays if the 2707RC is using the DIP switch control or software control for its configuration.

Software Version (softVersion2707RC) This displays the software version of code in the 2707RC.

Model 2707RC Configuration—Configuration page MIB variables description

The Model 2707RC Configuration—Configuration page enables you to update the configuration of the 2707RC NetLink-E1 NTU modems that are installed in the system. After making changes to the configuration on this page, select Back to return to the Model 2707RC Configuration Slot page, then select onLine as the Input Mode, and finally, select Submit Query to send the new information to the Model 1001MC over the net- work.

The following sections describes the MIB variables that are available on the Model 2707RC Configuration— Configuration page.

Line Status (lineStatus2707RC) This variable displays the status of the line. There are three possible values that can be displayed:

  • lineDown(1)
  • dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data
  • testMode(3)

Software Version (softVersion2707RC) This read-only MIB variable displays the current version of code that is running in the NetLink-E1 rack card modem.

Configuration Type (configType) This displays if the 2707RC is using the DIP switch control or software control for its configuration.

Model 2707RC Configuration—Configuration page MIB variables description 183

Page 184 of the Patton electronic 1001MC user manual — Unit Configuration table
Page 184 · click to enlarge
Page 184

Unit Configuration table This table shows the configurable MIB variables for the 2707RC card. After changes are made, select the Sub- mit Query button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model 2707RC Configuration page.

The following sections explain the MIB variables that are shown in the Unit Configuration table.

Line Format (lineFormat) This option should be set to G.703 unframed: frame-G703(0).

Clock Mode (clockMode2707RC) This variable defines the clock mode for the NetLink-E1 modems. The following options are available:

  • network-CLK(0)
  • internal-CLK(1)
  • external-CLK(2).

DTE Rate (dteRate2707RC) This read-only variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of activated channels.

Line Coding (lineCoding2707RC) This variable is used to select the G.703 line coding. The following options are available:

  • code-HDB3(0)—HDB3
  • code-AMI(1)—AMI

Line Build Out (lineBuildOut) This is used to select the line build out. The following options are available:

  • lbo-75ohm(0)—75 ohm
  • lbo-120ohm(1)—120 ohm

FP Switches (frntSwitch) This selects if the front panel toggle switches used for loopbacks and pattern generators are enabled(1) or dis- abled(0).

H/W Test mode (testModeSetInd) This read-only variable displays any test mode invoked from the toggle switches and DTE test mode lines. If the unit is in a test mode, this option will be highlighted in blue.

S/W Test mode (testModeSet2707RC) This is used to invoke test modes through the NMS. The only valid options for the 2707RC are:

  • off(0)
  • lal(4)—Local loopback

Model 2707RC Configuration—Configuration page MIB variables description 184

Page 185 of the Patton electronic 1001MC user manual — Slot Configuration page MIB variables description
Page 185 · click to enlarge
Page 185

Loop Timeout (loopTo) This selects the amount of time that the unit will remain in test mode when the remote test mode is invoked. If the responding unit is not taken out of test mode within this time period, the unit will automatically time out and return to normal data mode.

Test Mode from DTE (testModeDTE) When enabled, the 2707RC will respond to the LL signal coming from the DTE.

Config Type (configType) The following options are available:

  • switch-config(0)—The 2707RC is using the DIP switch control for its configuration
  • software-config(1)—The 2707RC is using the software control for its configuration

User Id (UserID) Displays the user-supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.

Slot Configuration page MIB variables description

This section describes the MIB variables that are available on the Slot Configuration page. From the Modem Information page, the address column creates a list of hyperlinks to the Slot Configuration page associated with the specified address. The Slot Configuration page can be used to set slot-specific information related to the sys- tem and how the system treats the slot in the case of errors and warning.

Card Address (nmsSlotID) Displays the address of the card.

Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.

View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).

Local User Id (localUserID) User supplied string that defines the NetLink NTU installed in the rack. The string is stored in non-volatile flash within the NetLink NTU and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within this page.

Slot Configuration page MIB variables description 185

Card Identification Information

Page 186 of the Patton electronic 1001MC user manual — Remote User Id (remoteUserID)
Page 186 · click to enlarge
Page 186

Remote User Id (remoteUserID) This feature is not supported by the Model 2707RC NTU.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.

Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warning) associated with the specified slot.

Hardware Reset (resetStatus) Selecting this push button will force the associated modem to perform a hardware reset.

Card Lost Indication (cardLostIndication) This variable allows you to choose what type of indication will be made if a modem is removed from the man- agement system. Three choices are available:

  • Error(2)
  • Warning(1)
  • None(0)

Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. Three choices are available:

  • Error(2)
  • Warning(1)
  • None(0)

Slot Configuration page MIB variables description 186

Alarm Information

Page 187 of the Patton electronic 1001MC user manual — Table of contents
Page 187 · click to enlarge
Page 187

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 188 of the Patton electronic 1001MC user manual — Table of contents
Page 188 · click to enlarge
Page 188

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 189 of the Patton electronic 1001MC user manual — Table of contents
Page 189 · click to enlarge
Page 189

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 190 of the Patton electronic 1001MC user manual — Configuration and management
Page 190 · click to enlarge
Page 190

Introduction

This chapter describes managing a Model 3088RC NetLink-G.SHDSL network termination unit (NTU) using the Model 1001MC NetLink-NMS internal HTTP/HTML web engine and a standard web browser. This chapter is meant to be used in addition to the manual that came with your unit.

NetLink-NMS description Specifically designed for use in the Patton NetLink system, when the NetLink-G.SHDSL NTU is coupled with the Model 1001MC NetLink-NMS and the Patton Model 1001 rack system, the modem is fully SNMP manage- able. SNMP management can be performed on both the local and remote units using a standard SNMP network management station (NMS) or by using a standard web browser and the Model 1001MC's built-in web server. You can view and change configuration variables, view statistical variables, and view error and warning indica- tions.

Configuration and management

This section describes the configuration and management of your NetLink G.SHDSL NTUs using a Model 1001MC NetLink-NMS with built in HTTP/HTML web server. If you plan to manage your units using a standard network management station you can download the Patton Enterprise MIBs either through the SNMP web page on the Model 1001MC or obtain them from the Patton web site at www.patton.com.

The following pages are used to configure and manage the Model 3088RC:

  • Modem Information Rack X page: This page displays a list of the cards that are installed in your system and a quick view of any errors or warnings associated with your modems (see section “Displaying the Modem Information page” on page 191)
  • Model 3088RC Configuration Slot X page: This page (along with the Model 3088RC Configuration page) enables you to make configuration changes to the Model 3088RC and the remote CPE box (see section “Displaying the Model 3088RC Configuration Slot page” on page 193)
  • Model 3088RC Configuration page: This page (along with the Model 3088RC Configuration Slot page) enables you to update configuration of modems installed in the system (see “Displaying the Model 3088RC Configuration page” on page 195)
  • Slot Configuration Page : This page can be used to set slot-specific information related to the system and how the system treats the slot in the case of errors or warnings (see section “Displaying the Model 3088RC Configuration Slot page” on page 193)

Introduction 190

Page 191 of the Patton electronic 1001MC user manual — Displaying the Modem Information page
Page 191 · click to enlarge
Page 191

Displaying the Modem Information page The Modem Information page (see figure 91) displays the cards installed in the system and a quick view of any errors or warnings associated with your modems.

Patton electronic 1001MC — Displaying the Modem Information page diagram (page 191)
Fig. 92 · Displaying the Modem Information page

Figure 91. Modem Information page for the Model 3088RC

Starting from the HOME page, to access the Modem Information Rack X page for the 3088RC, click on the fol- lowing links: Home (menu) > Configure Cards (menu) > View Rack [rack number]. Figure 92 on page 192 shows the web page navigation required to get to this area of the system. For more information about items on the Modem Information Rack X page, see “Displaying the Slot Configuration Page” on page 197.

Configuration and management 191

Page 192 of the Patton electronic 1001MC user manual — Displaying the Modem Information page
Page 192 · click to enlarge
Page 192
Patton electronic 1001MC — Displaying the Modem Information page diagram (page 192)
Fig. 93 · Displaying the Modem Information page

Figure 92. Web page navigation to Modem Information page

Configuration and management 192

Page 193 of the Patton electronic 1001MC user manual — Displaying the Model 3088RC Configuration Slot page
Page 193 · click to enlarge
Page 193

Displaying the Model 3088RC Configuration Slot page The Model 3088RC Configuration Slot page (see figure 93) enables you to make configuration changes to the Model 3088RC and the remote NTU. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Patton electronic 1001MC — Displaying the Model 3088RC Configuration Slot page diagram (page 193)
Fig. 94 · Displaying the Model 3088RC Configuration Slot page

Figure 93. Model 3088RC Configuration Slot page

Starting from the HOME page, to access the Model 3088RC Configuration Slot page for the 3088RC, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > model3088RC-xxx(x) (in the Local Model Code column) for the 3088RC you wish to manage (in the example shown in figure 93, the 3088RC was installed in slot 4). Figure 94 on page 194 shows the web page navigation required to get to this area of the system.

Configuration and management 193

Page 194 of the Patton electronic 1001MC user manual — Making configuration changes to your 3088RC NetLink NTU
Page 194 · click to enlarge
Page 194
Patton electronic 1001MC — Making configuration changes to your 3088RC NetLink NTU diagram (page 194)
Fig. 95 · Making configuration changes to your 3088RC NetLink…

Figure 94. Web page navigation to Model 3088RC Configuration Slot page

Making configuration changes to your 3088RC NetLink NTU Do use the following to make configuration changes to your NetLink NTU.

1. With the Model 3088RC Configuration Slot page displayed, change the Input Mode (see figure 93 ) to superVisoryMode . The Modify Configuration hyperlink will appear.
2. Click on the Modify Configuration hyperlink to display the Model 3088RC Configuration page.
3. Make your configuration changes or select the Set Default Configuration button.
4. Select the Submit Query button to place the changes into the 1001MC’s temporary memory. If you decide that you do not want your changes implemented, you can select the Clear Changes button.
5. Select the Back hyperlink to return to the Model 3088RC Configuration Slot page.
6. Change the Input Mode back to onLine and select the Submit Query button. When the unit returns to the online state, the 3088RC will begin implementing the configuration changes.

For more information about items on the Model 3088RC Configuration Slot page, see “Model 3088RC Con- figuration Slot X page MIB variables description” on page 201.

Configuration and management 194

Page 195 of the Patton electronic 1001MC user manual — Displaying the Model 3088RC Configuration page
Page 195 · click to enlarge
Page 195

Displaying the Model 3088RC Configuration page The Model 3088RC Configuration page (see figure 95) enables you to make configuration changes to the Model 3088RC and the remote CPE box.

Patton electronic 1001MC — Displaying the Model 3088RC Configuration page diagram (page 195)
Fig. 96 · Displaying the Model 3088RC Configuration page

Figure 95. Model 3088RC Configuration page

Starting from the HOME page, to access the Model 3088RC Configuration page for the 3088RC, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > model3088RC-xxx(x) (in the Local Model Code column) for the 3088RC you wish to manage > Modify Configuration (you first have to change input mode from onLine to superVisoryMode. Figure 96 on page 196 shows the web page navigation required to get to this area of the system.

For more information about items on the Model 3088RC Configuration page, see “Model 3088RC Configu- ration page MIB variables description” on page 206.

Configuration and management 195

Page 196 of the Patton electronic 1001MC user manual — Displaying the Model 3088RC Configuration page
Page 196 · click to enlarge
Page 196
Patton electronic 1001MC — Displaying the Model 3088RC Configuration page diagram (page 196)
Fig. 97 · Displaying the Model 3088RC Configuration page

Figure 96. Web page navigation to Model 3088RC Configuration page

Configuration and management 196

Page 197 of the Patton electronic 1001MC user manual — Displaying the Slot Configuration Page
Page 197 · click to enlarge
Page 197

Displaying the Slot Configuration Page The Slot Configuration Page (see figure 97) is used to set slot-specific information related to the system and how the system treats that slot in the case of errors or warnings.

Patton electronic 1001MC — Displaying the Slot Configuration Page diagram (page 197)
Fig. 98 · Displaying the Slot Configuration Page

Figure 97. Slot Configuration Page

Starting from the HOME page, to access the Slot Configuration page for the 3088RC, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > X in the Card_Address column for the 3088RC you wish to manage (in the example shown in figure 97, the 3088RC was installed in slot 4). Figure 98 on page 198 shows the web page navigation required to get to this area of the system.

Configuration and management 197

Page 198 of the Patton electronic 1001MC user manual — Modem Information Rack X page MIB variables description
Page 198 · click to enlarge
Page 198
Patton electronic 1001MC — Modem Information Rack X page MIB variables description diagram (page 198)
Fig. 99 · Modem Information Rack X page MIB variables descript…

Figure 98. Web page navigation to Slot Configuration Page

For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description” on page 209.

Modem Information Rack X page MIB variables description

This section describes the MIB variables that are available on the Modem Information Rack X page. Starting from the HOME page, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number].

Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.

Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.

Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.

Rack Protection Mode (rackXProtected) If you want to protect all Model 3088RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the drop-down menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.

Modem Information Rack X page MIB variables description 198

Page 199 of the Patton electronic 1001MC user manual — Submit button
Page 199 · click to enlarge
Page 199

Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.

Power Supply 1 Status (rackXPower1Down) Displays the current status of power supply 1 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Power Supply 2 Status (rackXPower2Down) Displays the current status of power supply 2 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.

Card Address (nmsSlotID) This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the Model 1095 Configuration Slot page. This page can be used to set slot-specific information about the card.

Line Status (lineStatus) The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:

  • startup(1)
  • dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data.

Modem Information Rack X page MIB variables description 199

Page 200 of the Patton electronic 1001MC user manual — Warnings (warningCount)
Page 200 · click to enlarge
Page 200
  • testMode(3)

Warnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more infor- mation on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warning for the slot can be erased in the Slot Configuration page.

Errors (errorCount) This field displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page.

Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.

Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration page for the NetLink modem and its remote unit. The model code information is passed to the Model 1001MC after the card is placed online. The Model 1001MC is auto- sensing, meaning that when a card is found or lost, the information will automatically be updated in the sys- tem. You are not required to setup the Model Code information for each slot. When a card is removed from the system, the Model Code will be erased and an error or warning will be displayed for the slot (this depends on the settings in the Slot Configuration page)

Remote User Id (remoteUserID)

Remote Model Code (remoteModelCode)

Modem Information Rack X page MIB variables description 200

Page 201 of the Patton electronic 1001MC user manual — Model 3088RC Configuration Slot X page MIB variables description
Page 201 · click to enlarge
Page 201

Protected (disableGlobalConfig) You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed within the Configure Cards page or from the Slot Configuration page. After clicking the Sub- mit Query button to input the string to the management system, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards web page or from the Slot Configuration page.

Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Model 3088RC Configuration Slot X page MIB variables description

This section describes the MIB variables that are available on the Model 3088RC Configuration Slot X page. (See figure 93 on page 193). Starting from the HOME page, click on the following links: Home (menu) > Config- ure Cards (menu) > View Rack [rack number] > model3088RC-xxx(x) (in the Local Model Code column).

Model 3088RC Configuration Slot (nmsSlotID) Displays the address of the NetLink E1-G.SHDSL NTU. The address is defined by the DIP-switch setting of S3 and S4 on the rack card.

Model 3088RC Configuration Slot X page MIB variables description 201

Page 202 of the Patton electronic 1001MC user manual — Line Status (lineStatus)
Page 202 · click to enlarge
Page 202

Line Status (lineStatus) Displays the status of the line. There are three possible values that can be displayed:

  • linedown(1)
  • dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data
  • testMode(3)

Alarm counters For the four alarm counters, you may choose to do numerous actions upon detecting errors: nothing, incre- ment the counter upon each occurrences of the error, send an SNMP trap, or send a Syslog message. The choice is determined by configuring the Line Down Indicator on the Slot Configuration Page. The following table clarifies what the parameter will do.

Send a Syslog message Increment the Alarm Counter

on the web page Send an SNMP trap

None ✔ Warning ✔ ✔ Error ✔ ✔ ✔

LOS (losAlarm) Displays the number of times Loss of Sync on the E1 line is detected. It is incremented when synchronization to the E1 stream is lost. This number is accumulating in the 1001MC.

  • none —Only Syslog message will be sent
  • warning —Syslog message will be sent beginning with “box\box.c: Warning:” and web page warning counter will be incremented
  • error —Syslog message will be sent beginning with “box\box.c: Error:”, the web page error counter will be incremented, and an SNMP trap message will be sent

Model 3088RC Configuration Slot X page MIB variables description 202

Page 203 of the Patton electronic 1001MC user manual — AIS (aisAlarm)
Page 203 · click to enlarge
Page 203

AIS (aisAlarm) Displays the number of times an Alarm Indication Signal on the E1 line is detected. This should be set when an unframed all ones code is received at RPOSI and RNEGI. This number is accumulating in the 1001MC.

  • none —Only Syslog message will be sent
  • warning —Syslog message will be sent beginning with “box\box.c: Warning:” and web page warning counter will be incremented
  • error —Syslog message will be sent beginning with “box\box.c: Error:”, the web page error counter will be incremented, and an SNMP trap message will be sent

Flap Count (lineDownCnt) Displays the number of times the E1 line has been up and then becomes down. This should be set when the E1 line is up and becomes down. This number is accumulating in the 1001MC.

  • none —Only Syslog message will be sent
  • warning —Syslog message will be sent beginning with “box\box.c: Warning:” and web page warning counter will be incremented
  • error —Syslog message will be sent beginning with “box\box.c: Error:”, the web page error counter will be incremented, and an SNMP trap message will be sent

CRC4 Error (crc4Error) Displays the number of CRC4 errors received by the E1 interface. This is an error counter that records word errors in the CRC4. The counter is disabled during loss of sync. This number is accumulating in the 1001MC.

  • none —Only Syslog message will be sent
  • warning —Syslog message will be sent beginning with “box\box.c: Warning:” and web page warning counter will be incremented
  • error —Syslog message will be sent beginning with “box\box.c: Error:”, the web page error counter will be incremented, and an SNMP trap message will be sent

The Clear Counter button This button clears all alarm counters.

Model 3088RC Configuration Slot X page MIB variables description 203

Page 204 of the Patton electronic 1001MC user manual — CRC4 Error Alarm Threshold (crc4Threshold)
Page 204 · click to enlarge
Page 204

CRC4 Error Alarm Threshold (crc4Threshold) The valid setting for the threshold is 0 to 255. By setting a threshold, the CRC4 Alarm counter will not issue the error/warning, Syslog, and SNMP Trap message unless the accumulating CRC4 Error Counter is greater than the threshold. The Record Current Configuration button will store the setting of the alarm threshold.

Input Mode (mode3088RC) The following settings are available:

  • onLine(0)
  • superVisoryMode(1)

To make configuration changes to the NetLink-E1 NTUs, you must first set this bit to superVisoryMode(1). When the Input Mode is set to superVisoryMode1), the Modify Configuration hyperlink will appear. Select the Modify Configuration hyperlink. The Model 3088RC Configuration page will appear (see section “Model 3088RC Configuration page MIB variables description” on page 206 for more information). After making configuration changes to the NetLink-E1 NTUs in the Model 3088RC Configuration page, return to this page by clicking on the Back… hyperlink and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has completed and will cause it to copy the new configuration into the NetLink-E1 NTU configuration space. If this is not done, the NetLink-E1 NTU will not recognize the config- uration changes that were made.

Model 3088RC Configuration Slot page Configuration Status table description The Configuration Status table shows the configuration for the set of units. There are columns for the local and remote units. If a field is highlighted in yellow, it signifies one of two possible conditions:

  • At start up, the Model 1001MC will display a default configuration for the card and all fields will be highlighted in yellow, notifying you that the information has not been verified. During the negotiation phase, the NetLink-E1 NTU modem will update the configuration in the Model 1001MC with its last set of stored parameters. As these fields are updated in the Model 1001MC, the yellow highlighting will disappear, signifying that the information has been updated. After the local and remote units are linked, the units will begin updating the remote information in the table, and Line Status set to datamode(2).
  • If a rack card is installed in the rack without a customer premise unit connected, the remote information will be left as either none or highlighted in yellow, notifying you that the information has not been verified.

The following sections define the MIB variables that are shown in the Configuration Status table.

Configuration Status (configStatus3088RC) This is the title of the status table and displays the configuration status of the rack card. The following status can be displayed:

  • Negotiating(0)—The 1001MC is receiving the rack card’s configuration for the first time
  • Static(1)—The 1001MC is showing the updated and correct configuration for the 3088RC
  • ImplementingChanges(2)—The 1001MC is updating configuration changes to the 3088RC.

Local Model Code (localModelCode/remoteModelCode) These variables display the local and remote models codes for the units that were found in the specified address.

Model 3088RC Configuration Slot X page MIB variables description 204

Page 205 of the Patton electronic 1001MC user manual — DTE Rate (dteRate3088RC)
Page 205 · click to enlarge
Page 205

DTE Rate (dteRate3088RC) This variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of acti- vated channels.

Clock Mode (clockMode3088RC) This variable defines the clock mode for the NetLink-E1 modems. The following status variables can be dis- played:

  • network-CLK(0)
  • internal-CLK(1)
  • external-CLK(2)

TX Clock Invert (tcClockInvert3088RC) • enable(0)

  • disable(1)

DSL Link Enable (dslLinkEnable3088RC) • enable(0)

  • disable(1)

Line Probe (lineProbe3088RC) Enables or disables the Line Probe feature to negotiate the optimal rate for current line conditions

  • enable(0)
  • disable(1)

Annex Type (annexType3088RC) Sets the DSL annex type

  • annexA(0)
  • annexB(1)

SW Test Mode (testModeSet3088RC) This displays any test mode invoked through the NMS. See next configuration for information about invoking test modes through the NMS. This option will be highlighted in blue if the unit is in test mode.

  • none(0)-No test mode in process
  • lal(1)-Local loopback test
  • rdl(2)-Remote loopback

Front Panel Switches (frontPannelSwitches3088RC) • This variable allows or disallows the front panel switches to cause the unit to go into test mode.

  • enable(0)
  • disable(1)

Model 3088RC Configuration Slot X page MIB variables description 205

Page 206 of the Patton electronic 1001MC user manual — Model 3088RC Configuration page MIB variables description
Page 206 · click to enlarge
Page 206

Response to Test Mode (responseToTestMode3088RC) This variable allows or disallows test modes to be initiated front both the front panel or from the remote unit.

  • enable(0)
  • disable(1)

Software Version (softVersion3088RC) This displays the software version of code in the 3088RC.

Reset button Software reset the E-carrier function card on its next poll from 1001MC.

Model 3088RC Configuration page MIB variables description

The Model 3088RC Configuration page enables you to update the configuration of the 3088RC NetLink-E1 NTU modems that are installed in the system. After making changes to the configuration on this page, select Back to return to the Model 3088RC Configuration Slot page, then select onLine as the Input Mode, and finally, select Submit Query to send the new information to the Model 1001MC over the network. Starting from the HOME page, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > model3088RC-xxx(x) (in the Local Model Code column) > change input mode to Supervisory > Modify Configura- tion.

The following sections describes the MIB variables that are available on the Model 3088RC Configuration— Configuration page.

DSL Link State (lineStatus3088) This variable displays the status of the line. There are three possible values that can be displayed:

  • success(1) -When the line status is dataMode(2), the units are linked-up and ready to send data
  • deactivated (2)
  • in-progress (3)

DSL Link State (dSLSyncState3088) This variable displays the status of the line. There are three possible values that can be displayed:

  • acquiring-sync (1)
  • in-sync (2)
  • losing-sync (3)

Software Version (softVersion3088RC) This read-only MIB variable displays the current version of code that is running in the NetLink-E1 rack card modem.

Model 3088RC Configuration page MIB variables description 206

Page 207 of the Patton electronic 1001MC user manual — Configuration Type (configType)
Page 207 · click to enlarge
Page 207

Configuration Type (configType) This displays if the 3088RC is using the DIP switch control or software control for its configuration.

Unit Configuration table This table shows the configurable MIB variables for the set of units. After changes are made, select the Submit Query button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model 3088RC Configuration page.

The following sections explain the MIB variables that are shown in the Unit Configuration table.

Clock Mode (clockMode3088RC) This variable defines the clock mode for the NetLink-E1 modems. The following options are available:

  • network-CLK(0)
  • internal-CLK(1)
  • external-CLK(2).

DTE Rate (dteRate3088RC) This read-only variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of activated channels.

TX Clock Invert (tcClockInvert3088RC) • enable(0)

  • disable(1)

DSL Link Enable (dslLinkEnable3088RC) • enable(0)

  • disable(1)

Line Probe (lineProbe3088RC) Enables or disables the Line Probe feature to negotiate the optimal rate for current line conditions

  • enable(0)
  • disable(1)

Line Coding (lineCoding3088RC) This variable is used to select the G.703 line coding. The following options are available:

  • code-HDB3(0)—HDB3
  • code-AMI(1)—AMI

Line Build Out (lineBuildOut) This is used to select the line build out. The following options are available:

  • lbo-75ohm(0)—75 ohm
  • lbo-120ohm(1)—120 ohm

Model 3088RC Configuration page MIB variables description 207

Page 208 of the Patton electronic 1001MC user manual — Tx Clock Timing (txClock)
Page 208 · click to enlarge
Page 208

Tx Clock Timing (txClock) The following options are available:

  • external(0)—serial transmit data coming from the DTE is clocked in using the DTE provided external clock
  • internal(1)—serial transmit data coming from the DTE is clocked in using the DCE provided transmit clock

Model 3088RC Configuration page MIB variables description 208

Page 209 of the Patton electronic 1001MC user manual — Slot Configuration page MIB variables description
Page 209 · click to enlarge
Page 209

Software Test Mode (testModeSet3088RC) This is used to invoke test modes through the NMS. Available options are:

  • lal(4)—Local loopback test
  • rdl(7)—Remote loopback test from V54

RDL Response(v54Loop) The following options are available:

  • enabled(1)—The unit will respond to a V.54 loop up command
  • disabled(0)—The unit will ignore a V.54 loop up command

FP Switches (frntSwitch) This selects if the front panel toggle switches used for loopbacks and pattern generators are:

  • enabled(1)
  • disabled(0).

Slot Configuration page MIB variables description

This section describes the MIB variables that are available on the Slot Configuration page. From the Modem Infor- mation page, the address column creates a list of hyperlinks to the Slot Configuration page associated with the spec- ified address. The Slot Configuration page can be used to set slot-specific information related to the system and how the system treats the slot in the case of errors and warning. Starting from the HOME page, click on the follow- ing links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > X (in the Card Address column).

Card Address (nmsSlotID) Displays the address of the card.

Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.

View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).

Local User Id (localUserID) User supplied string that defines the NetLink NTU installed in the rack. The string is stored in non-volatile flash within the NetLink NTU and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within this page.

Slot Configuration page MIB variables description 209

Card Identification Information

Page 210 of the Patton electronic 1001MC user manual — Remote User Id (remoteUserID)
Page 210 · click to enlarge
Page 210

Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non- volatile flash within the CP unit. If the unit is moved, the User ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within this page.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.

Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warning) associated with the specified slot.

Hardware Reset (resetStatus) Selecting this push button will force the associated modem to perform a hardware reset.

Card Lost Indication (cardLostIndication) This variable allows you to choose what type of indication will be made if a modem is removed from the man- agement system. Three choices are available:

  • None(0)
  • Warning(1)
  • Error(2)

Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. Three choices are available:

  • None(0)
  • Warning(1)
  • Error(2)

Slot Configuration page MIB variables description 210

Alarm Information

Page 211 of the Patton electronic 1001MC user manual — Creating and modifying global configuration templates
Page 211 · click to enlarge
Page 211

Creating and modifying global configuration templates

Model 3088RC rack cards can be configured globally by templates you create. If you use this capability, you have the option to globally configure some or all Model 3088RC NTUs in multiple racks, or those in just one rack.

This section contains the following information to help you configure and use templates:

  • Protecting individual Model 1001 racks and 3088RC rack cards from global modification—You may not want all racks or NTUs to be modified when you apply the global template, so section “Protecting Model 1001 racks and Model 3088RC NTUs from global modification” describes how to protect individual 1001 racks and 3088RC NTUs from being globally configured.
  • Creating a template (see section “Creating a template” on page 214)
  • Modifying a template (see section “Modifying a template” on page 216)
  • Deleting a template (see section “Deleting a template” on page 217)
  • Applying a template (see section “Applying a template” on page 217)

Protecting Model 1001 racks and Model 3088RC NTUs from global modification This section describes how to protect 1001 racks and 3088RC NTU cards from being modified when a global modification is applied. This is useful if you are setting all but a few cards to the same configuration. You may protect an entire rack or only selected individual rack cards.

  • To protect an entire Model 1001 rack, see the section “Protecting an entire Model 1001 rack from global configuration” on page ….
  • To protect a selected Model 3088RC rack card, see section “Protecting a Model 3088RC rack card from global configuration” on page ….

Protecting an entire Model 1001 rack from global configuration Do the following to protect a Model 1001 rack:

Creating and modifying global configuration templates 211

Page 212 of the Patton electronic 1001MC user manual — Creating and modifying global configuration templates
Page 212 · click to enlarge
Page 212
1. Starting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 99 .
Patton electronic 1001MC — Creating and modifying global configuration templates diagram (page 212)
Fig. 100 · Creating and modifying global configuration template…

Figure 99. System Level Information page

2. Use the Rack Protection Mode pop-up menu (see figure 99 ) to select protected(1).

Creating and modifying global configuration templates 212

Page 213 of the Patton electronic 1001MC user manual — Protecting a selected Model 3088RC rack card from global configuration
Page 213 · click to enlarge
Page 213
3. Click the Apply Protection button.

The rack is now protected.

Protecting a selected Model 3088RC rack card from global configuration Do the following to protect a single Model 3088RC rack card:

1. Starting from the HOME page, click on the following links: Configure Cards > View Rack 1 (choose the rack you want to protect, in the example, rack 1 was selected).
2. Locate the card address (see figure 55 on page 119) of the Model 3088RC you want to protect.
3. Set the Protected pop-up menu (see figure 55 on page 119) to protected(1).
4. Click the Submit button.

The rack card is now protected.

Creating and modifying global configuration templates 213

Page 214 of the Patton electronic 1001MC user manual — Creating a template
Page 214 · click to enlarge
Page 214

Creating a template This section describes how to create a global configuration template.

Patton electronic 1001MC — Creating a template diagram (page 214)
Fig. 101 · Creating a template

Figure 100. Global Configuration Menu page

Do the following to create a template:

1. In the Create New Configuration section, type a short name (10 characters or less) in the text box named Model 3088RC/2707RC Configuration: ( see figure 100 ). Clicking on the Create Configuration button, creates the new template and displays the Model 3088RC Global Configuration window.

Creating and modifying global configuration templates 214

Page 215 of the Patton electronic 1001MC user manual — Creating a template
Page 215 · click to enlarge
Page 215

Figure 101 is the Unit Configuration section (see figure 101) for the configuring E1 link parameters. There are 16 configurable parameters. What follows is a description of them with the available options for each.

Patton electronic 1001MC — Creating a template diagram (page 215)
Fig. 102 · Creating a template

Figure 101. Unit Configuration section of the web management table

  • DTE Rate Use the dropdown menu to select an available DTE rate
  • Clock Mode , this selects the source of the clock used for the Transmit signal on the E1 channel. Please note the difference from “Tx Clock Timing” described below.

- network-CLK(0)—derived from the received signal from the network

- internal-CLK(1)—driven by the internal oscillator in the 3088RC NTU

- external-CLK(2)—provided by DTE External Transmit Clock signal

  • DSL Link Enable (dslLinkEnable3088RC)
  • Line Probe (lineProbe3088RC) Enables or disables the Line Probe feature to negotiate the optimal rate for current line conditions
  • Annex Type (annexType3088RC) Sets the DSL annex type

Creating and modifying global configuration templates 215

Show 6 more labels / short text on this page
- enable(0) · - disable(1) · - enable(0) · - disable(1) · - annexA(0) · - annexB(1)
Page 216 of the Patton electronic 1001MC user manual — Modifying a template
Page 216 · click to enlarge
Page 216
  • SW Test Mode (testModeSet3088RC) This displays any test mode invoked through the NMS. See next configuration for information about invoking test modes through the NMS. This option will be highlighted in blue if the unit is in test mode.

- none(0)-No test mode in process

- lal(1)-Local loopback test

  • FP Switch (Front Panel)

- disabled (0)—disables the toggle switches on the front panel of the 3088RC rack card

- enabled(1)—enables the ability to use the front panel toggle switches

  • Response to Test Mode , refers to the initiation of loopbacks via one of the DTE signals.

- disabled(0)—no loopbacks can be initiated by a DTE signal

- enabled(1)—Loopbacks can be initiated by a DTE signal.

Refer to section “Applying a template” on page 217 to activate the template.

Modifying a template This section describes how to modify a global configuration template.

Patton electronic 1001MC — Modifying a template diagram (page 216)
Fig. 103 · Modifying a template

Figure 102. Global Configuration Menu page

Do the following to modify a template:

Creating and modifying global configuration templates 216

- rdl(2)-Remote loopback

Page 217 of the Patton electronic 1001MC user manual — Deleting a template
Page 217 · click to enlarge
Page 217
1. Select a template from the Modify Configuration pop-up menu (see figure 102 ), then click the Modify Configuration button.
2. Change the parameters requiring modification (see figure 103 ). When you have finished changing the configuration, click on the Submit button to save the changes.

Refer to section “Applying a template” on page 217 to activate the template.

Deleting a template Do the following to delete a template:

1. Select a template from the Delete Configuration pop-up menu (see figure 102 on page 216).
2. Click the Delete Configuration button.

Applying a template This section describes how to apply a global configuration to all Model 3088RC rack cards. Model 3088RC cards which will not be configured to the selected Global Configuration are:

  • Those installed in a Model 1001 rack that has the entire rack set to be protected(1)
  • Those that are individually set to protected(1) mode

Instructions for protecting either an entire rack or individual 3088RC cards are given earlier in this chapter.

The template can be applied to:

  • All 3088RC NTUs in ALL Model 1001 racks
  • All 3088RC NTUs in just ONE Model 1001 rack

To configure all Model 3088RC rack cards in all Model 1001 racks Complete the following steps.

1. Starting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 103 .

Creating and modifying global configuration templates 217

Page 218 of the Patton electronic 1001MC user manual — Deleting a template
Page 218 · click to enlarge
Page 218
Patton electronic 1001MC — Deleting a template diagram (page 218)
Fig. 104 · Deleting a template

Figure 103. System Level Information page—System Overview section

2. Use the Apply 3088RC System Configuration pop-up menu (see figure 103 ) to select the template you want to apply.
3. Click the Apply Configuration button.

The template has been applied.

Creating and modifying global configuration templates 218

Page 219 of the Patton electronic 1001MC user manual — To configure all Model 3088RC rack cards in just one Model 1001 rack
Page 219 · click to enlarge
Page 219

To configure all Model 3088RC rack cards in just one Model 1001 rack Complete the following steps:

1. Starting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 104 .
Patton electronic 1001MC — To configure all Model 3088RC rack cards in just one Model 1001 rack diagram (page 219)
Fig. 105 · To configure all Model 3088RC rack cards in just one…

Figure 104. System Level Information page—Rack section

2. Locate the rack section of the System Level Information page that you will configure (in figure 104 , Rack 1Top Level is being modified).
3. Use the Apply Rack Configuration pop-up menu (see figure 104 ) to select the template you want to apply.
4. Click the Apply Configuration button.

The template has been applied.

Creating and modifying global configuration templates 219

Page 220 of the Patton electronic 1001MC user manual — Table of contents
Page 220 · click to enlarge
Page 220

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 221 of the Patton electronic 1001MC user manual — Table of contents
Page 221 · click to enlarge
Page 221

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 222 of the Patton electronic 1001MC user manual — Table of contents
Page 222 · click to enlarge
Page 222

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 223 of the Patton electronic 1001MC user manual — Table of contents
Page 223 · click to enlarge
Page 223

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 224 of the Patton electronic 1001MC user manual — Introduction
Page 224 · click to enlarge
Page 224

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Introduction

This section describes how to navigate the internal HTTP/HTML web pages on the Model 1001MC. The diagram below shows how all of the web pages are linked together. Following figure 105, there is a brief description of each page.

Patton electronic 1001MC — Introduction diagram (page 224)
Fig. 106 · Introduction

Figure 105. 1001MC command map

Figure 106. 1001MC login window

Login After typing the IP address into your web browser as the URL, the Model 1001MC will present the login screen (see figure 106). The Model 1001MC has two levels of password protection, superuser and monitor. The Model 1001MC has two levels of password protection:

  • superuser —The superuser password level lets you view statistics and make configuration changes to the system. To log in as a superuser, type the word superuser , all lower case, as the username and password

Introduction 224

Page 225 of the Patton electronic 1001MC user manual — HOME
Page 225 · click to enlarge
Page 225

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

  • monitor —The monitor level password enables you to view statistics, but it will not let you make any configuration changes. To log into the system at the monitor level, type monitor , all lower case, for the username and password.

After logging in, the system displays the HOME page (see figure 107).

Figure 107. HOME page

HOME The HOME page displays a quick overview of the system including; error and warning indications, software information, box names, number of modems installed, and so on.

On the left side of the HOME page is the Navigation View. The list on the left side of the screen allows you to navigate to any page from this point. The navigation page will always be available to you so you can change from one page to the next.

The Record Current Configuration button lets you store configuration changes made to the box.

Introduction 225

Page 226 of the Patton electronic 1001MC user manual — About 1001MC
Page 226 · click to enlarge
Page 226

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

The Hard Reset button forces the 1001MC to perform a reset. This will not reset the individual cards in the rack only the 1001MC. If you would like to perform a hardware reset on the individual cards, refer to the Slot Configuration page.

See section “HOME” on page 228 for more information.

About 1001MC The About 1001MC page gives a more in-depth overview of the system that presented on the HOME page. This page also provides contact information about Patton Electronics. See section “About 1001MC” on page 231 for more information.

Import/Export The Import/Export function enables you to make a backup (or export) copy of the 1001MC rack’s configura- tion parameters. By exporting the configurations,l the saved files can quickly be loaded, or imported, into a replacement 1001MC rack—greatly speeding up the installation process should a rack need to be replaced. Additionally, you may have multiple racks requiring the same configuration. This simplifies and accelerates the installation.

Patton electronic 1001MC — About 1001MC diagram (page 226)
Fig. 107 · About 1001MC

Figure 108. The Import/Export web management page.

Configure Cards Clicking on the Configure Cards hyperlink displays the System Level Information page. This page is the starting point for the configuration and management of your Patton NetLink modems. This page enables you to quickly identify potential problems and view statistics on a per-rack basis. You can also disable racks from this level. For more information, see section “System Level Information” on page 235.

Introduction 226

Page 227 of the Patton electronic 1001MC user manual — Modem Information Page
Page 227 · click to enlarge
Page 227

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

From this page, you can select a View Rack hyperlink that will display the Modem Information Page for the selected rack.

Modem Information Page The Modem Information Page consists of a table that displays top level information about the cards installed in the selected rack. These items include; model codes, user IDs, errors and warning, and circuit IDs. This page also allows you to gain information about the number of cards and power supplies in the rack. (See section “Modem Information Rack X” on page 239 for more information).

From this page there are two hyperlinks that can be selected that will give you detailed information about a specific modem. These are the Slot Configuration hyperlink, shown as the address of the card in the table, and the Modem Statistics hyperlink, shown as the local model code.

Slot Configuration. The Slot Configuration page enables you to enter information about the modem installed. From the page, you can change the User IDs, Circuit IDs, and the Error and Warning Indications. From this page, you can also clear errors and warning and perform a hardware reset on the modem installed in the rack (see section “Slot Configuration” on page 243 for more information).

Modem Statistics. The Modem Statistics page shows the current configuration and statistical state of the local and remote modem installed at the selected address. From this page, you can place the card into the superVisoryMode. Once the card is in this mode, the web page will display a hyperlink that will allow you to enter the Modem Configuration Page.

Modem Configuration Page. The Modem Configuration page allows you to change the configuration of the local and remote modems installed at the selected address. This page can also be used to place the cards into test modes. Once the configuration has been setup, submit the changes, then return to the Modem Statistics page to place the modem into the onLine state.

System Information You can navigate to the System Information page by selecting the hyperlink along the left side of any page. The System Information page enables you to setup the IP information, box information, and password information for the system. It is recommended that you change your passwords immediately after installing your Model 1001MC to ensure security for your network (see section “System Information” on page 246 for more information).

Download The Download page enables you to perform software upgrades on the 1001MC itself, and the 1094ARC and 1095RC NetLink rack card modems installed in the system. New software can be obtained from Patton Electron- ics via a file-transfer protocol (FTP) connection (see section “Download” on page 249 for more information).

System Log The System Log page displays Syslog messages. Syslog messaging is a reporting tool used in the Model 1001MC to log run-time operations. There are several levels of messages and you can set the system to report only messages above a certain level. From this page, you can reach the Syslog—Modify, Modify—Volatile Memory, and Mod- ify—Non-Volatile Memory web pages. See section “System Log” on page 251 for more information about the System Log page.

Introduction 227

Page 228 of the Patton electronic 1001MC user manual — HOME 228
Page 228 · click to enlarge
Page 228

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Syslog—Modify The Syslog—Modify web page allows you to setup the configuration for the Syslog messaging system. You can set variables such as the IP address of a Syslog Daemon and priority levels for each of the messaging facilities (see section “System Log—Modify” on page 252 for more information).

Syslog—Volatile Memory The Syslog—Volatile Memory page displays Syslog messages that have been sent to the Volatile Memory sec- tion of the messaging system. The messages stored here will be lost if the system is re-booted (see section “Sys- tem Log—Volatile Memory” on page 256 for more information).

Syslog—Non-Volatile Memory The Syslog—Non-Volatile Memory page displays Syslog messages that have been sent to the Non-Volatile Memory section of the messaging system. The messages stored here will be stored in Flash memory and will be available if the system is re-booted or power is lost (see section “System Log—Non-Volatile Memory” on page 257 for more information).

SNMP The SNMP web page enables you to download the Patton Enterprise MIBs for the Model 1001MC. These MIBs are required if you plan to manage the system using a network management station (NMS) instead of the web page manager.

HOME

The HOME page is the first HTTP/HTML screen that you will reach after you log into the Model 1001MC (see figure 107 on page 225). From the HOME page you may monitor the current system status, save any sys- tem changes or reset the system without powering off the rack system.

Patton electronic 1001MC — HOME diagram (page 228)
Fig. 108

Figure 109. Box information

There are six system variables which describe information about the 1001MC. These variables are shown in figure 109, and are described in the following sections.

Software Version (boxSoftwareVersion) This variable defines the version of the software currently running in the Model 1001MC. The Model 1001MC can be software upgraded using an FTP download.

Software Date Code (boxDateCode) This variable defines the date and time the software was compiled.

HOME 228

Box information

Page 229 of the Patton electronic 1001MC user manual — HOME 229
Page 229 · click to enlarge
Page 229

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Box Name (boxName) This variable displays a user defined string that represents the name of the box. This variable can be changed by the user in the System Info web page.

Box Contact (boxContact) This variable displays a user defined string that represents the contact for the box. You can change this variable in the System Info web page.

Box Location (boxLocation) This variable displays a user defined string that represents the location of the box. You can change this variable in the System Info web page.

Running Since Last Boot (boxUpTime) This variable tells you how long the Model 1001MC has been running since it was last reset.

Patton electronic 1001MC — Box Name (boxName) diagram (page 229)
Fig. 109 · Box Name (boxName)

Figure 110. Operating status variables

Operating status variables There are four system variables which describe the immediate operating status of the NetLink modems installed in the rack. These variables are shown in figure 110 and are described in the following sections.

Total System Slots Available (totalConfigSlots) This read-only variable defines the largest address that the system will POLL (address 1 to totalConfigSlots). Any NetLink modem with an address outside of this range will not be found by the Model 1001MC.

Total Active Slots (totalActiveSlots) This read-only variable defines the number of NetLink modems currently installed in the system. As the Model 1001MC brings the modems online this number is incremented. After a card is removed from the system, this number is decrement.

Total System Warnings (boxWarningNumber) This variable defines the number of warnings that are currently outstanding in the system. This number includes warnings that have been generated from the NetLink modems as well as the Model 1001MC itself. If this number is greater than zero, this field will be highlighted in yellow to notify you that the warning exists. Warnings are cleared through the Configure Cards web page for the system, or the Slot Configuration page for the individual modems. You can view the System Log page to examine the source of the warnings.

Total System Errors (boxErrorNumber) This variable defines the number of errors that are currently outstanding in the system. This number includes errors that have been generated from the NetLink modems as well as the Model 1001MC itself. If this number is greater than zero, this field will be highlighted in red to notify you that the errors exists. Errors are cleared

HOME 229

Page 230 of the Patton electronic 1001MC user manual — HOME 230
Page 230 · click to enlarge
Page 230

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

through the Configure Cards web page for the system, or the Slot Configuration page for the individual modems. You can view the System Log page to examine the source of the warnings.

Patton electronic 1001MC — Immediate Actions diagram (page 230)
Fig. 110 · Immediate Actions

Figure 111. Immediate actions

Immediate Actions There are several immediate actions which can be executed on the Model 1001MC, when in superuser mode (see figure 111), which will cause the box to act according to the following:

  • Record Current Configuration —Selecting the Record Current Configuration button causes the current configuration to be stored in Flash memory. Any changes made to the Model 1001MC configuration are stored in non-volatile RAM first. This allows you to set the box up with a working configuration before making the configuration permanent. Changes become permanent when you select Record Current Configuration . You will lose all changes not stored to Flash the next time the 1001MC is re-booted unless you store them.
  • Hard Reset —Clicking the Hard Reset button causes the 1001MC to restart. When you select Hard Reset , the 1001MC confirms that you want to execute this command. Then, the 1001MC will re-initialize the interfaces, and re-load configuration parameters from Flash.

HOME 230

Page 231 of the Patton electronic 1001MC user manual — About 1001MC
Page 231 · click to enlarge
Page 231

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Patton electronic 1001MC — About 1001MC diagram (page 231)
Fig. 111 · About 1001MC

Figure 112. About 1001MC

About 1001MC

The About 1001MC link displays system information and the following Patton Electronics Company contact information:

Patton Electronics Co. 7622 Rickenbacker Drive Gaithersburg, Maryland 20879, U.S.A.

Phone+1 (301) 975-1000
Fax+1 (301) 869-9293
E-mailsupport@ patton.com
WWWwww.patton.com

About 1001MC 231

Page 232 of the Patton electronic 1001MC user manual — About 1001MC
Page 232 · click to enlarge
Page 232

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Patton electronic 1001MC — About 1001MC diagram (page 232)
Fig. 112 · About 1001MC

Figure 113. System Level Information page

About 1001MC 232

Page 233 of the Patton electronic 1001MC user manual — Import Export
Page 233 · click to enlarge
Page 233

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Import Export

The Import/Export function enables you to make a backup (or export) copy of your Model 1001MC’s configura- tion parameters. By exporting the configurations, the saved files can quickly be loaded, or imported, into a replace- ment Model 1001MC—greatly speeding up the installation process should the Model 1001MC need replacing.

To import or export a configuration, click on Import/Export under the Configuration Menu to display the Import/Export main window (see figure 114).

Figure 114. Import/Export main window

Export Configuration · Import Export 233

Page 234 of the Patton electronic 1001MC user manual — Import Export
Page 234 · click to enlarge
Page 234

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

To export the flash configuration, click on the Export Flash link on the Import/Export main page. The Model 1001MC will display text configuration information resembling that shown in figure 115.

Patton electronic 1001MC — Import Export diagram (page 234)
Fig. 113 · Import Export

Figure 115. Typical access server flash memory configuration data

To save the displayed data as a text file, select the Save option on your browser (see figure 116). For example, under Netscape, select File > Save As. A dialog box will display enabling you to save the contents of the export parameters to a text file. Select the location where you want the file stored, type a file name, and click Save.

Patton electronic 1001MC — Import Export diagram (page 234)
Fig. 114 · Import Export

Figure 116. Saving the access server flash memory configuration data as a text file

Import Export 234

Page 235 of the Patton electronic 1001MC user manual — System Level Information
Page 235 · click to enlarge
Page 235

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Import Configuration To import a configuration file into the access server, type the complete path and filename for the configuration file you wish to load or click on the Browse… button to select the desired file, then click on the Submit Query button (see figure 114 on page 233).

Upon successfully importing the file, the access server will display Configuration Load Complete, indicating that the new operating parameters have been loaded into flash memory.

Click on HOME under the Configuration Menu, then click on the Hard Reset button under Immediate Actions.

System Level Information

Clicking the Configure Cards hyperlink on the HOME page displays the System Level Information page. Figure 113 displays a portion of the information page for the NetLink system being managed. The System Level Information page contains statistical information about the entire system and explains how that information is broken down among the racks. Each rack can be enabled or disabled from this level. When a rack is disabled, the 1001MC stops polling the addresses contained in the specified rack. The 1001MC’s ability to stop polling is use- ful when installing less than eight racks or when taking cards offline in order to perform servicing. The modems installed in the system will continue to operate at the last setting provided. This page also allows you to clear alarms on a per-rack or system basis. Each rack view also contains a View Rack hyperlink to the Modem Informa- tion page (see section “Modem Information Rack X” on page 239 for more information). The following sections describe the variables contained within the System Level Information page.

System Overview This section of the System Level Information window (see figure 113 on page 232) does the following:

  • Displays status information compiled from all Model 1001 racks in the system
  • Provides several test patterns for use when running diagnostics in system test mode
  • Enables you to apply global system configurations to Model 1095RC, 2701RC, and 2707RC rack cards installed in the system

Apply System Configuration If you are applying a global configuration to all Model 1095RC, 2701RC, and 2707RC rack cards in the sys- tem, select the desired template from the pop-up menu, then click the Apply Configuration button. For more information about the system configuration feature (including how to protect rack cards and racks from being modified), refer to section “System Config” on page 259.

System Level Information 235

Page 236 of the Patton electronic 1001MC user manual — Apply System Test Mode
Page 236 · click to enlarge
Page 236

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Apply System Test Mode If you are going to be running in system test mode, select one of the following test patterns from the pop-up menu, then click the Apply Test Mode button.

  • off(0)
  • five11(2)—511 is the pattern that is used when the pattern generator and detector are turned on
  • five11er(3)—511 with errors is the pattern that is used when the pattern generator and detector are turned on
  • lal(4)—Local loopback
  • lalWith511(5)—Local loopback with pattern generator set to output 511 pattern
  • lalWith511er(6)—Local loopback with pattern generator set to output 511 pattern with errors
  • rdl(7)—Remote digital loopback
  • rdlWith511(8)—Remote digital loopback with pattern generator set to output 511 pattern
  • rdlWith511er(9)—Remote digital loopback with pattern generator set to output 511 pattern with errors

Total Slots Available (totalConfigSlots) Displays the number of configurable slots available in the system.

Total Cards Installed (totalActiveSlots) Displays the number of cards the system has found.

Power Supplies Installed (boxPowerSupplies) Displays the number of power supplies installed in the system.

Total System Warnings (boxWarningNumber) Displays the number of warnings that have been generated by the system.

Total System Errors (boxErrorNumber) Displays the number of errors that have been generated by the system.

Clear All System Alarms (clearAlarms) Click on this button to clear alarms for the entire system.

Rack X Top Level The following variables are used by each rack in the system. Replace the X shown in the variable name with the appropriate rack number to label the specific variable name (i.e. rack2Enable).

System Level Information 236

Page 237 of the Patton electronic 1001MC user manual — Rack X Enable (rackXEnable)
Page 237 · click to enlarge
Page 237

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Rack X Enable (rackXEnable) This is where you can enable or disable a rack for use by the system. You will almost always want to have the rack enabled, but it can be useful to disable a rack if:

  • Your system configuration has fewer rack cards than will fill the number of installed racks, in which case all un-installed racks should be disabled. The 1001MC will not poll the address range for a rack that is disabled, so this will shorten the time needed to poll the system.
  • You would like to remove cards from the rack without generating an alarm. Disabling the rack prevents it from sending alarms to the 1001MC.

View Rack X hyperlink Click on this link to display the Modem Information Rack X page. The Modem Information Rack page displays an overview of the NetLink rack that is being managed. For more information, refer to section “Modem Informa- tion Rack X” on page 239.

Address Range Displays the addresses (in groups of 15) that will be polled for the defined rack (for example, the address range for rack 1 would be 1-15, rack 2 would be 16-30, and so on).

Total Slots Available (rackXSlotsAvailable) Displays the number of slots available for the rack (based on the number of power supplies installed in the rack).

Total Cards Installed (rackXCardsInstalled) Displays the number of cards that the system has found.

Power Supplies Installed (rackXPowerSupplies) Displays the number of power supplies installed in the rack (this value determines the addressing range for the rack).

Total Errors (rackXErrorNumber) Displays the number of errors that have been reported by the system for this rack.

Total Warnings (rackXWarningNumber) Displays the number of warnings that have been reported by the system for this rack.

Apply Rack Configuration If you are applying a global configuration to Model 1095RC, 2701RC, and 2707RC rack cards installed in the rack, select the desired template from the pop-up menu, then click the Apply Configuration button. For more information about the system configuration feature (including how to protect rack cards from being modified), refer to section “System Config” on page 259.

System Level Information 237

Page 238 of the Patton electronic 1001MC user manual — Apply Test Mode
Page 238 · click to enlarge
Page 238

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Apply Test Mode If you are going to be running in test mode, select one of the following test patterns from the pop-up menu, then click the Apply Test Mode button.

  • off(0)
  • five11(2)—511 is the pattern that is used when the pattern generator and detector are turned on
  • five11er(3)—511 with errors is the pattern that is used when the pattern generator and detector are turned on
  • lal(4)—Local loopback
  • lalWith511(5)—Local loopback with pattern generator set to output 511 pattern
  • lalWith511er(6)—Local loopback with pattern generator set to output 511 pattern with errors
  • rdl(7)—Remote digital loopback
  • rdlWith511(8)—Remote digital loopback with pattern generator set to output 511 pattern
  • rdlWith511er(9)—Remote digital loopback with pattern generator set to output 511 pattern with errors

Rack Protection Mode If you want to protect all Model 1095RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the pop-up menu, then click the Apply Protection button. For more information about the system configuration feature, refer to section “System Config” on page 259.

Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms reported by the system for this rack.

System Level Information 238

Page 239 of the Patton electronic 1001MC user manual — Modem Information Rack X
Page 239 · click to enlarge
Page 239

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Modem Information Rack X

The Modem Information Rack X page displays an overview of the NetLink rack that is being managed. This page will display statistical information, such as errors and warnings on a per-card basis, and identification information, such as model codes and user IDs. Figure 117 shows the Modem Information page, a description of each variable follows.

Patton electronic 1001MC — Modem Information Rack X diagram (page 239)
Fig. 115 · Modem Information Rack X

Figure 117. Modem Information page

Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.

Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.

Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.

Modem Information Rack X 239

Page 240 of the Patton electronic 1001MC user manual — Rack Protection Mode
Page 240 · click to enlarge
Page 240

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Rack Protection Mode If you want to protect all Model 1095RC, 2701RC, and 2707RC rack cards installed in the current rack from being globally configured, select protected(1) from the pop-up menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.

Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.

Power Supply 1 Status Displays the current status of power supply 1 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Power Supply 2 Status Displays the current status of power supply 2 as one of the following:

  • available(0)—The power supply is working normally.
  • down(1)—If the status is shown as down , it means the 1001MC is unable to detect the power supply. This status listing will also be highlighted in red.
  • notInstalled(2)—The power supply has not been installed.

Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.

Card Address (nmsSlotID) Defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is setup using the DIP-switches on the card. For more information about setting the address of a card, please refer to the appropriate NMS version of the manual for the specific NetLink modem. The address is also a hyperlink to the Slot Configuration page (see section “Slot Configuration” on page 243 for more informa- tion). This page can be used to set slot specific information about the card.

Modem Information Rack X 240

Page 241 of the Patton electronic 1001MC user manual — Line Status
Page 241 · click to enlarge
Page 241

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Line Status The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:

  • startup(1)
  • dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data.
  • testMode(3)

Warnings (warningCount) Displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more information on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warnings for the slot can be erased in the Slot Configuration page (see section “Slot Configuration” on page 243 for more information).

Errors (errorCount) Displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page (see section “Slot Configuration” on page 243 for more information).

Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page (see section “Slot Configuration” on page 243 for more information).

Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration of the NetLink modem and its remote unit. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page (see section “Slot Configu- ration” on page 243 for more information)

Remote User Id (remoteUserID) User supplied string that defines the unit at the end of the link. The string is stored in non-volatile flash within the unit. If the unit is moved, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page (see section “Slot Configuration” on page 243 for more information).

Modem Information Rack X 241

Page 242 of the Patton electronic 1001MC user manual — Remote Model Code (remoteModelCode)
Page 242 · click to enlarge
Page 242

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Remote Model Code (remoteModelCode) This column displays the model code of the NetLink modem at the far end of the link.

Protected You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards page or from the Slot Configuration page (see section “Slot Config- uration” on page 243 for more information). After you have set the local circuit ID, if you are finished making changes to the current rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards page or from the Slot Configuration page (see section “Slot Config- uration” on page 243 for more information).

Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.

Modem Information Rack X 242

Page 243 of the Patton electronic 1001MC user manual — Slot Configuration
Page 243 · click to enlarge
Page 243

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Slot Configuration

The Slot Configuration page (see figure 118) enables you to make slot specific configuration changes that are not product specific. The following sections describe each variable.

Figure 118. Slot Configuration Page

Card Address (nmsSlotID) Displays the address of the card.

Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.

View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).

Local User Id (localUserID) 10-byte user-supplied string that defines the NetLink modem installed in the rack. The string is stored in non- volatile Flash within the NetLink modem. If the address of the modem is changed, the User ID will move to the new slot.

Card Identification Information · Slot Configuration 243

Page 244 of the Patton electronic 1001MC user manual — Remote User Id (remoteUserID)
Page 244 · click to enlarge
Page 244

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

To configure the local user ID, type the ID into the Local User ID text box, then click the Submit button {located next to the Remote User ID text box) to save the changes.

Clear Local ID button. If you want to delete the local ID information, click on the Clear Local ID button, then click on the Submit button.

Remote User Id (remoteUserID) 10-byte user supplied string that defines the remotely connected modem. The string is stored in non-volatile Flash within the NetLink modem.

To configure the remote user ID, type the ID into the Remote User ID text box, then click the Submit button {located next to the Remote User ID text box) to save the changes.

Clear Remote ID button. If you want to delete the remote ID information, click on the Clear Remote ID button, then click on the Submit button.

Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile Flash within the Model 1001MC.

To configure the local circuit ID, type the ID into the Local Circuit ID text box, then click the Submit button {located next to the Local Circuit ID text box) to save the changes.

Clear Local Circuit ID button. If you want to delete the local circuit ID information, click on the Clear Local Circuit ID button, then click on the Submit button.

Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile Flash within the Model 1001MC.

Slot Configuration 244

Page 245 of the Patton electronic 1001MC user manual — Alarm Information
Page 245 · click to enlarge
Page 245

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

To configure the remote circuit ID, type the ID into the Remote Circuit ID text box, then click the Submit but- ton {located next to the Remote Circuit ID text box) to save the changes.

Clear Remote Circuit ID button. If you want to delete the remote circuit ID information, click on the Clear Remote Circuit ID button, then click on the Submit button.

Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warnings) associated with the specified slot.

Hardware Reset (resetStatus) Selecting this button will force the current rack card modem to perform a hardware reset.

Card Lost Indication (cardLostIndication) This variable lets you choose what type of indication will be made if a modem is removed from the manage- ment system. The following options are available:

  • none(0)
  • warning(1)—If a card lost situation occurs, it will be displayed in yellow highlighting as a warning on the HOME , System Level Information , and Modem Information Rack pages.
  • error(2)—If a card lost situation occurs, it will be displayed in red highlighting as an error on the HOME , System Level Information , and Modem Information Rack pages

Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. The following options are available:

  • none(0)
  • warning(1)—If a line down situation occurs, it will be displayed in yellow highlighting as a warning on the HOME , System Level Information , and Modem Information Rack pages.
  • error(2)—If a line down situation occurs, it will be displayed in red highlighting as an error on the HOME , System Level Information , and Modem Information Rack pages

Alarm Information · Slot Configuration 245

Page 246 of the Patton electronic 1001MC user manual — System Information
Page 246 · click to enlarge
Page 246

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

System Information

The System Information page (see figure 119) displays the current setting for the system. This page allows you to setup parameters defining password protection and the network address. A description of each variable follows figure 119.

Patton electronic 1001MC — System Information diagram (page 246)
Fig. 116 · System Information

Figure 119. System Information

IP Address (boxIpAddress) Displays the IP address of the box.

IP Mask (boxIpMask) Displays the IP mask of the box.

Current Gateway (boxGateway) Displays the current gateway for the network.

Current System Information · System Information 246

Page 247 of the Patton electronic 1001MC user manual — Modifying the IP addressing
Page 247 · click to enlarge
Page 247

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Modifying the IP addressing

IP Address (boxIpAddress) This parameter defines the IP address of the box. Type the address into the text box, then, if you have no other IP addressing entries to make, click the Submit button.

IP Mask (boxIpMask) This parameter defines the IP mask of the box. Type the address into the text box, then, if you have no other IP addressing entries to make, click the Submit button.

Gateway (boxGateway) This parameter defines the current gateway for the network. Type the address into the text box, then, if you have no other IP addressing entries to make, click the Submit button.

Box Location (boxLocation) User defined string that represents the location of the box. This variable is displayed on the HOME page.

Type the box location into the text box, then, if you have no other box contact entries to make, click the Sub- mit button.

Box Name (boxName) User defined string that represents the name of the box. This variable is displayed on the HOME page.

Type the box name into the text box, then, if you have no other box contact entries to make, click the Submit button.

Box Contact (boxContact) User defined string that represents the contact for the box. This variable is displayed on the HOME page.

Type the box contact information into the text box, then, if you have no other box contact entries to make, click the Submit button.

SNMP and HTTP Password Information

Superuser Password (boxSnmpMasterPassword) This password will allow full access rights to the box (read-write). Change the password by typing the new password into the Superuser Password and Superuser Password Verification fields, then click the Submit button.

Box Contact Information · System Information 247

Page 248 of the Patton electronic 1001MC user manual — User Password (boxSnmpMonitorPassword)
Page 248 · click to enlarge
Page 248

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

User Password (boxSnmpMonitorPassword) This password will allow monitor access rights to the box (read-only). Change the password by typing the new password into the User Password and User Password Verification fields, then selecting the Submit button.

Background Information (boxBackgroundFlag) The Model 1001MC contains a background image that can be used while viewing the web pages. You can choose to enable or disable the background image, then click on the Submit button to apply the change.

Web Page Refresh Rate (BoxWebRefreshRate) The user may choose to refresh certain web configuration pages at various rates or no automatic refresh. The following pages are refreshed at the rate selected:

  • 1095RC configuration page
  • 1094RC configuration page
  • 2701RC configuration page
  • 2707RC configuration page
  • iDSL configuration page
  • Rack view page

The user’s selection of auto refresh rates are:

  • none(0)—no auto refresh. The user must refresh the web page manually
  • rate5sec(5)—5 seconds between auto refreshing
  • rate10sec(10)—10 seconds
  • rate15sec(15)—15 seconds
  • rate30sec(30)—30 seconds
  • rate1min(60)—1 minute
  • rate2min(120)—2 minutes
  • rate3min(180)—3 minutes
  • rate5min(300)—5 minutes

System Information 248

Page 249 of the Patton electronic 1001MC user manual — Download
Page 249 · click to enlarge
Page 249

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Web Background Enabled (boxBackgroundFlag) The Model 1001MC contains a background image that can be used while viewing the web pages. You can choose to enable or disable the background image, then click on the Submit button to apply the change. The two options are:

  • disableGraphics(0)—there is no background image. The background is white.
  • enableGraphics(1)—the background image is visible.

Figure 120. Download page

Download

The Model 1001MC has the facilities to download new Flash software into itself and the following NetLink modems:

  • 1094ARC (see section “Using the Download page to upgrade 1094ARC software” on page 87 for information on upgrading the Flash software)
  • 1095RC (see section “Using the Download page to upgrade 1095RC software” on page 111 for information on upgrading the Flash software)

Upgrading 1001MC software via FTP download This section describes how to upgrade the Flash memory in the Model 1001MC. You will need the following:

  • PC with FTP utility installed.

Download 249

Page 250 of the Patton electronic 1001MC user manual — Web Background Enabled (boxBackgroundFlag)
Page 250 · click to enlarge
Page 250

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

  • 1001MC with access to the LAN.
1. At the C:\> DOS prompt on the PC, type the following:

ftp where <IP ADDRESS> is the IP address of the 1001MC.

The 1001MC will respond with the following:

Connected to

220 Code download service ready

User ( < IP ADDRESS > (none)):

2. To download 1001MC operational code enter the username as KillImage (1001MC commands are casesensitive so type it exactly as shown).

The 1001MC will respond with the following:

331 User name okay, need password.

Password:

3. Enter the superuser password for the box—the default password is superuser , but it may have been changed by the system administrator, in which case, use the new password.

The 1001MC will respond with the following:

230 User logged in, proceed.

4. The type of file being downloaded needs to be specified, type the following at the prompt:

FTP> “type image” The 1001MC will respond with the following:

200 Command okay.

5. Send the file by typing the following:FTP> “send ” where is the full filename of the file to be downloaded, including the directory (for example: c:\temp\1001MC.img ).

The 1001MC will respond with the following:

Response: 200 Command okay.

150 File status okay; about to open data connection.

226 Closing data connection.

Connection closed by remote host.

There will be a few second delay after the data connection is opened while the file is being transferred, then the connected will be closed. The 1001MC will automatically install the new software.

Download 250

Page 251 of the Patton electronic 1001MC user manual — System Log
Page 251 · click to enlarge
Page 251

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Patton electronic 1001MC — System Log diagram (page 251)
Fig. 117 · System Log

Figure 121. System Log

System Log

The System Log page (see figure 121) displays an overview of the system logging functions. The system log is a messaging system that stores information about the system as it is running. The following hyperlinks are avail- able for modifying and viewing system log messages:

  • System Log—Modify : This page enables you to modify the system log parameters. You can choose which messages will be sent to the available message logging functions (see section “System Log—Modify” on page 252 for more information).
  • System Log—Volatile Memory : This page contains a log of messages that have been sent to the RAM storage area using the Min Priority for RAM variable in the Syslog Modify page. Messages stored here will be lost if the box reboots (see “System Log—Volatile Memory” on page 256 for more information).
  • System Log—Non-Volatile Memory : This page contains a log of messages that have been sent to the Flash storage are using the Min Priority for Flash Storage variable in the Syslog Modify page. Messages stored here will be saved even if the box reboots (see “System Log—Non-Volatile Memory” on page 257 for more information).

System Log 251

Page 252 of the Patton electronic 1001MC user manual — System Log—Modify
Page 252 · click to enlarge
Page 252

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Patton electronic 1001MC — System Log—Modify diagram (page 252)
Fig. 118 · System Log—Modify

Figure 122. System Log—Modify

System Log—Modify

The System Log—Modify page (see figure 122) allows you to modify the system log parameters. You can choose which messages will be sent to the available message logging functions.

Syslog Daemon IP Address (syslogDaemonIP) The Model 1001MC can send messages over a network to a Syslog Daemon. This variable specifies the IP address that will be running the Syslog Daemon. Type the IP address into the text box, then click the Submit button.

Daemons · System Log—Modify 252

Page 253 of the Patton electronic 1001MC user manual — SNMP Trap Daemon IP Address (syslogTrapIP)
Page 253 · click to enlarge
Page 253

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

SNMP Trap Daemon IP Address (syslogTrapIP) SNMP traps are generated for line down, line up, card lost, power supply 1 fail, and power supply 2 fail events. The specific trap numbers are as follows:

Trap Description Specific Trap Number

TRAP_ID_POWER_ONE_FAIL 1 TRAP_ID_POWER_TWO_FAIL 2 TRAP_ID_CARD_LOST 3 TRAP_ID_LINE_UP 4 TRAP_ID_LINE_DOWN 5

The Trap IP address is assigned on the System Log page. If the IP address is assigned, SNMP traps will be sent to that IP address. For line up and line down traps, Line down indication has to be set to error(2) on the Slot Configuration page for each card (see section “Slot Configuration” on page 243).

The line up, line down, and card lost trap messages will include the box name, rack number, card number in that rack, and local circuit ID in the trap string followed by a description of the trap. For example, the string in a line up trap will resemble: Model 1001MC Demo, Rack Number: 1, Card Number: 12, Local Circuit ID: Test Circuit, Line Up Addr: 12.

Type the IP address into the text box, then click the Submit button.

Min Priority for SysLog Daemon Specify the minimum priority for a message that will be sent to the SysLog Daemon. The following options are available:

  • priorityVerbose(5)
  • priorityDebug(10)
  • priorityInfo(20)
  • priorityOddity(40)
  • priorityService(60)
  • prioritySystem(80)
  • priorityDisable(1000)

For most situations, set the outputs that are being used to prioritySystem(80). For unused output mechanisms, set the priority to priorityDisable(1000). Select the priority setting from the pop-up menu, then click the Sub- mit button.

Priority · System Log—Modify 253

Page 254 of the Patton electronic 1001MC user manual — Min Priority for Flash Storage
Page 254 · click to enlarge
Page 254

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Min Priority for Flash Storage Specify the minimum priority for a message that will be sent to Flash storage. The following options are available:

  • priorityVerbose(5)
  • priorityDebug(10)
  • priorityInfo(20)
  • priorityOddity(40)
  • priorityService(60)
  • prioritySystem(80)
  • priorityDisable(1000)

For most situations, set the outputs that are being used to prioritySystem(80). For unused output mechanisms, set the priority to priorityDisable(1000). Select the priority setting from the pop-up menu, then click the Sub- mit button.

Min Priority for RAM Specify the minimum priority for a message that will be sent to RAM. The following options are available:

  • priorityVerbose(5)
  • priorityDebug(10)
  • priorityInfo(20)
  • priorityOddity(40)
  • priorityService(60)
  • prioritySystem(80)
  • priorityDisable(1000)

For most situations, set the outputs that are being used to prioritySystem(80). For unused output mechanisms, set the priority to priorityDisable(1000). Select the priority setting from the pop-up menu, then click the Sub- mit button.

System Log—Modify 254

Page 255 of the Patton electronic 1001MC user manual — Unix Facility
Page 255 · click to enlarge
Page 255

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

uration changes into memory (see “HOME” on page 228 for more information).

Unix Facility Specify the minimum priority for a message that will be sent to Flash storage. The following options are available:

  • disable(0)
  • user(1)
  • mail(2)
  • daemon(3)
  • auth(4)
  • syslog(5)
  • lpr(6)
  • news(7)
  • uucp(8)
  • cron(9)
  • authpriv(10)
  • ftp(11)
  • local0(16)
  • local1(17)
  • local2(18)
  • local3(19)
  • local4(20)
  • local5(21)
  • local6(22)
  • local7(23)

Select the facility setting from the pop-up menu, then click the Submit button.

System Log—Modify 255

Page 256 of the Patton electronic 1001MC user manual — System Log—Volatile Memory
Page 256 · click to enlarge
Page 256

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Maintain Flash Storage (syslogFlashClear) This variable is used to notify you about the status of the flash storage area. The following options are available:

  • syslogFlashOK(0)
  • syslogFlashFull(1)—If the flash storage area is full this variable will read syslogFlashFull
  • syslogFlashClear(2)—The flash storage area can be erased by setting this variable to syslogFlashClear and selecting the Submit Query button

System Log—Volatile Memory

The System Log—Volatile Memory page (see figure 123) contains a log of messages that have been sent to the RAM storage area using the Min Priority for RAM variable in the Syslog Modify page. Messages stored here will be lost if the box reboots.

Patton electronic 1001MC — System Log—Volatile Memory diagram (page 256)
Fig. 119 · System Log—Volatile Memory

Figure 123. System Log—Volatile Memory

System Log—Volatile Memory 256

Maintenance

Page 257 of the Patton electronic 1001MC user manual — System Log—Non-Volatile Memory
Page 257 · click to enlarge
Page 257

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

System Log—Non-Volatile Memory

The System Log—Volatile Memory page (see figure 124) contains a log of messages that have been sent to the flash storage are using the Min Priority for Flash Storage variable in the Syslog Modify page. Messages stored here will be saved even if the box reboots. This page will show warnings highlighted in yellow and errors high- lighted in red. When an error or warning is displayed somewhere in the web pages, this page will give a descrip- tion of the error/warning. All information on this page is read-only except a single push button at the top of the page which is described in more detail below.

Patton electronic 1001MC — System Log—Non-Volatile Memory diagram (page 257)
Fig. 120 · System Log—Non-Volatile Memory

Figure 124. System Log—Non-Volatile Memory

Erase Flash Messages (syslogFlashClear) Clicking on this button clears messages listed on the page. This function can also be performed from the Sys- log Modify page.

System Log—Non-Volatile Memory 257

Page 258 of the Patton electronic 1001MC user manual — SNMP 258
Page 258 · click to enlarge
Page 258

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

SNMP

The SNMP Support Page (see figure 125) is where you can download the MIBs used by the 1001MC. You will need the MIBs if you will be using an SNMP Network Management Station and a standard SNMP software package or MIB walking tool to manage your Patton NetLink System instead of the built-in NetLink-NMS HTTP/HTML management pages.

Patton electronic 1001MC — SNMP diagram (page 258)
Fig. 121

Figure 125. SNMP Support Page

The following options are available:

  • corporate mib—Click on this link to download the corporate MIB file (corporat.mib)
  • products mib—Click on this link to download the products MIB file (product.mib)
  • 1001MC Products Mibs Page—Click on this link to view (and download) the product-specific MIBs used by the 1001MC

SNMP 258

Page 259 of the Patton electronic 1001MC user manual — System Config
Page 259 · click to enlarge
Page 259

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

System Config

Model 1095RC, 2701RC, and 2707RC rack cards can be configured globally by templates you create. If you use this capability, you have the option to globally configure some or all Model 1095RC, 2701RC, and 2707RC modems in multiple racks, or those in just one rack.

This section contains the following information to help you configure and use templates:

  • Protecting individual Model 1001 racks and 1095RC rack cards from global modification—You may not want all racks or modems to be modified when you apply the global template, so section “Protecting Model 1001 racks and Model 1095RC modems from global modification” describes how to protect individual 1001 racks and 1095RC modems from being globally configured.
  • Creating a template (see section “Creating a template” on page 263)
  • Modifying a template (see section “Modifying a template” on page 267)
  • Deleting a template (see section “Deleting a template” on page 271)
  • Applying a template (see section “Applying a template” on page 271)

Protecting Model 1001 racks and Model 1095RC modems from global modification This section describes how to protect 1001 racks and 1095RC modem cards from being modified when a glo- bal modification is applied. This is useful if you are setting all but a few cards to the same configuration.

Select the appropriate option from following configuration choices:

  • Protect a Model 1001 rack (see section “Protecting a Model 1001 rack from global configuration” on page 260)
  • Protect a Model 1095RC rack card (see section “Protecting a Model 1095RC rack card from global configuration” on page 262)

System Config 259

Page 260 of the Patton electronic 1001MC user manual — Protecting a Model 1001 rack from global configuration
Page 260 · click to enlarge
Page 260

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Protecting a Model 1001 rack from global configuration Do the following to protect a Model 1001 rack:

1. Starting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 126 . Figure 127 on page 261 shows the web page navigation required to get to this area of the system.

Figure 126. System Level Information page

System Config 260

Page 261 of the Patton electronic 1001MC user manual — Protecting a Model 1001 rack from global configuration
Page 261 · click to enlarge
Page 261

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Patton electronic 1001MC — Protecting a Model 1001 rack from global configuration diagram (page 261)
Fig. 122 · Protecting a Model 1001 rack from global configurati…

Figure 127. Web page navigation to System Level Information page

2. Use the Rack Protection Mode pop-up menu (see figure 126 ) to select protected(1) .
3. Click the Apply Protection button.

The rack is now protected.

System Config 261

Page 262 of the Patton electronic 1001MC user manual — Protecting a Model 1095RC rack card from global configuration
Page 262 · click to enlarge
Page 262

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Protecting a Model 1095RC rack card from global configuration Do the following to protect a single Model 1095RC rack card:

1. Starting from the HOME page, click on the following links: Configure Cards > View Rack 1 (choose the rack you want to protect, in the example shown in figure 128 , rack 1 was selected). Figure 129 shows the web page navigation required to get to this area of the system.
Patton electronic 1001MC — Protecting a Model 1095RC rack card from global configuration diagram (page 262)
Fig. 123 · Protecting a Model 1095RC rack card from global conf…

Figure 128. Modem Information Rack 1 page

Patton electronic 1001MC — Protecting a Model 1095RC rack card from global configuration diagram (page 262)
Fig. 124 · Protecting a Model 1095RC rack card from global conf…

Figure 129. Web page navigation to Modem Information Rack 1 page

System Config 262

Page 263 of the Patton electronic 1001MC user manual — Creating a template
Page 263 · click to enlarge
Page 263

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

2. Locate the card address (see figure 128 on page 262) of the Model 1095RC you want to protect.
3. Set the Protected pop-up menu (see figure 128 on page 262) to protected(1) .
4. Click the Submit button.

The rack card is now protected.

Creating a template This section describes how to create a global configuration template. The Patton Model 1095 enables the Model 1001MC system administrator to configure the units for a wide variety of applications. Due to the many different applications that are supported, care must be taken when setting the configuration of your modems. There are several illegal combinations of variables that could cause problems with the modems if implemented incorrectly. Be sure to read the following information before creating a template:

  • Configuration rules—Things to keep in mind when creating a template (see section “Configuration rules” on page 263)
  • Notes on clock mode settings (see section “Notes on clock mode settings” on page 264)
  • Notes on framing mode settings (see section “Notes on framing mode settings” on page 264)
  • Illegal configuration messages (see section “Illegal configuration messages” on page 264)

After reviewing the rules and notes, go to section “Procedure for creating a template” on page 265 to learn how to create a template.

Configuration rules Keep in mind the following when creating a template:

  • If you have an IM2RC/K G.703/G.704 Rear Card installed with a 1095RC in your rack, the unit must have the Local Clock Mode set to external and the Framing Mode set to slotted .
  • If you have an IM1/K G.703/G.704 Quick Connect Module installed with your 1095 at the remote site, the units must have the Clock Mode set to external-external and the Framing Mode for both the local and remote units must be set to slotted .
  • If you have any other interface connected to your 1095RC or your 1095 modems, the Framing Mode must be set to normal .
  • The system administrator should only set the Clock Mode to external-external(4) if there is an IM2RC/K installed in the 1095RC at the rack and an IM1/K installed in the 1095 standalone unit at the remote site.
  • When setting a unit for the external clock mode, the unit must have an external clock source in order to make a link. When using either an IM2RC/K or an IM1/K, the K module will always provide the external clock for the unit, so it is not necessary to have a G.703/G.704 link available. When using any other type of serial interface, make sure that an external clock is provided by the DTE equipment or the modems will not link.

System Config 263

Page 264 of the Patton electronic 1001MC user manual — Notes on clock mode settings
Page 264 · click to enlarge
Page 264

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

  • internal-receiveRecover(0)
  • external-receiveRecover(1)

There are special situations which would require the use of the external-external(4) clock mode setting. This setting should only be used when the application has an IM2RC/K and a 1095RC in the rack system and a IM1/K and a 1095 standalone at the remote site. If you are using any other interface cards do not use the exter- nal-external(4) configuration.

Notes on framing mode settings The Framing Mode Setting notifies the card of the type of interface it will be connected to. When you are using an IM2RC/K with a 1095RC rack card, the system administrator should set the Local Clock Mode to external (either external-receiveRecover(1) or external-external(4)) and the Local Framing Mode to slotted. When you are using an IM1/K and a 1095 standalone at the remote site, the system administrator should set the Clock Mode to external-external(4) and the Remote Framing Mode to slotted.

Illegal configuration messages If you are receiving an invalid configuration indication after creating a configuration, it is resulting from an illegal combination of variables. In most cases, the cause of the problem has to do with the Framing Mode vari- able. Patton DSL modems should only be set to the slotted mode when you are using an IM2RC/K with the 1095RC or an IM1/K with the 1095 standalone unit. Also, if you are using a IM2RC/K or IM1/K interface card, the 1095/1095RC must always be set to the external clock mode. Review the table below for a list of valid configurations that can be used with the 1095/1095RC.

Local Clock Mode Local Framing Mode Remote Clock Mode Remote Framing Mode

Internal Normal Receive Recover Normal External Normal Receive Recover Normal

Externala Slotted Receive Recover Normal

Externala Slotted Externala

Slotted Receive Recover Normal Internal Normal Receive Recover Normal External Normal

a. Denotes a unit that must have an IM2RC/K or IM1/K installed.

System Config 264

Page 265 of the Patton electronic 1001MC user manual — Procedure for creating a template
Page 265 · click to enlarge
Page 265

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Procedure for creating a template

Figure 130. Global Configuration Menu page

Do the following to create a template:

1. Click in the Model 1095 Configuration text box (see figure 130 ) and type a short name (10 characters or less) for the new template, then click the Create Configuration button.

The Model 1095 Global Configuration window displays (see figure 131).

Figure 131. Model 1095 Global Configuration page

System Config 265

Page 266 of the Patton electronic 1001MC user manual — Procedure for creating a template
Page 266 · click to enlarge
Page 266

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

2. Use the Local DTE Rate pop-up menu to select local DTE rate. You have the following choices:

– rate64k(3) – rate640k(12) – rate1280k(22) – rate1856k(32)

– rate128k(4) – rate704k(13) – rate1344k(23) – rate1920k(33)

– rate192k(5) – rate768k(14) – rate1408k(24) – rate1984k(34)

– rate256k(6) – rate832k(15) – rate1472k(25) – rate2048k(35)

– rate320k(7) – rate896k(16) – rate1536k(26) – rate2112k(36)

– rate384k(8) – rate960k(17) – rate1600k(28) – rate2176k(37)

– rate448k(9) – rate1024k(18) – rate1664k(29) – rate2240k(38)

– rate512k(10) – rate1088k(19) – rate1728k(30) – rate2304k(39)

– rate576k(11) – rate1216k(21) – rate1792k(31)

3. Use the Local Clock Mode (Local-Remote) pop-up menu to select the clock mode. You have the following choices:
4. Use the Local Tx Data Sample Point pop-up menu to select the local transmit data sample point. You have the following choices:
5. Use the Remote Tx Data Sample Point pop-up menu to select the remote transmit data sample point. You have the following choices:
6. Configure the Local TM from DTE pop-up menu using the following choices:
7. Configure the Remote TM from DTE pop-up menu using the following choices:
8. Configure the Local Framing Mode pop-up menu using the following choices:
Show 15 more labels / short text on this page
– internal-receiveRecover(0) · – external-receiveRecover(1) · – receiveRecover-internal(2) · – receiveRecover-external(3) · – external-external(4) · – normal(0) · – inverted(1) · – normal(0) · – inverted(1) · – disabled(0) · – enabled(1) · – disabled(0) · – enabled(1) · – slotted(0) · System Config 266
Page 267 of the Patton electronic 1001MC user manual — Modifying a template
Page 267 · click to enlarge
Page 267

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

9. Configure the Remote Framing Mode pop-up menu using the following choices:
10. When you have finished setting the configuration, click on the Submit button to save the changes.

Refer to section “Applying a template” on page 271 to activate the template.

Modifying a template This section describes how to modify a global configuration template. The Patton Model 1095 enables the Model 1001MC system administrator to configure the units for a wide variety of applications. Due to the many different applications that are supported, care must be taken when setting the configuration of your modems. There are several illegal combinations of variables that could cause problems with the modems if implemented incorrectly. Be sure to read the following information before creating a template:

  • Configuration rules—Things to keep in mind when creating a template (see section “Configuration rules” on page 267)
  • Notes on clock mode settings (see section “Notes on clock mode settings” on page 268)
  • Notes on framing mode settings (see section “Notes on framing mode settings” on page 268)
  • Illegal configuration messages (see section “Illegal configuration messages” on page 268)

After reviewing the rules and notes, go to section “Procedure for modifying a template” on page 269 to learn how to modify a template.

Configuration rules Keep in mind the following when modifying a template:

  • If you have an IM2RC/K G.703/G.704 Rear Card installed with a 1095RC in your rack, the unit must have the Local Clock Mode set to external and the Framing Mode set to slotted .
  • If you have an IM1/K G.703/G.704 Quick Connect Module installed with your 1095 at the remote site, the units must have the Clock Mode set to external-external and the Framing Mode for both the local and remote units must be set to slotted .
  • If you have any other interface connected to your 1095RC or your 1095 modems, the Framing Mode must be set to normal .
  • The system administrator should only set the Clock Mode to external-external(4) if there is an IM2RC/K installed in the 1095RC at the rack and an IM1/K installed in the 1095 standalone unit at the remote site.
  • When setting a unit for the external clock mode, the unit must have an external clock source in order to make a link. When using either an IM2RC/K or an IM1/K, the K module will always provide the external clock for
Show 4 more labels / short text on this page
– normal(3) · – slotted(0) · – normal(3) · System Config 267
Page 268 of the Patton electronic 1001MC user manual — Notes on clock mode settings
Page 268 · click to enlarge
Page 268

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

the unit, so it is not necessary to have a G.703/G.704 link available. When using any other type of serial inter- face, make sure that an external clock is provided by the DTE equipment or the modems will not link.

  • internal-receiveRecover(0)
  • external-receiveRecover(1)

There are special situations which would require the use of the external-external(4) clock mode setting. This setting should only be used when the application has an IM2RC/K and a 1095RC in the rack system and a IM1/K and a 1095 standalone at the remote site. If you are using any other interface cards do not use the exter- nal-external(4) configuration.

Notes on framing mode settings The Framing Mode Setting notifies the card of the type of interface it will be connected to. When you are using an IM2RC/K with a 1095RC rack card, the system administrator should set the Local Clock Mode to external (either external-receiveRecover(1) or external-external(4)) and the Local Framing Mode to slotted. When you are using an IM1/K and a 1095 standalone at the remote site, the system administrator should set the Clock Mode to external-external(4) and the Remote Framing Mode to slotted.

Illegal configuration messages If you are receiving an invalid configuration indication after creating a configuration, it is resulting from an illegal combination of variables. In most cases, the cause of the problem has to do with the Framing Mode vari- able. Patton DSL modems should only be set to the slotted mode when you are using an IM2RC/K with the 1095RC or an IM1/K with the 1095 standalone unit. Also, if you are using a IM2RC/K or IM1/K interface card, the 1095/1095RC must always be set to the external clock mode. Review the table below for a list of valid configurations that can be used with the 1095/1095RC.

Local Clock Mode Local Framing Mode Remote Clock Mode Remote Framing Mode

Internal Normal Receive Recover Normal External Normal Receive Recover Normal

Externala Slotted Receive Recover Normal

Externala Slotted Externala

Slotted Receive Recover Normal Internal Normal Receive Recover Normal External Normal

a. Denotes a unit that must have an IM2RC/K or IM1/K installed.

System Config 268

Page 269 of the Patton electronic 1001MC user manual — Procedure for modifying a template
Page 269 · click to enlarge
Page 269

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Procedure for modifying a template

Figure 132. Global Configuration Menu page

Do the following to modify a template:

1. Select a template from the Modify Configuration pop-up menu (see figure 130 ), then click the Modify Configuration button.

The Model 1095 Global Configuration window displays (see figure 131).

Figure 133. Model 1095 Global Configuration page

System Config 269

Page 270 of the Patton electronic 1001MC user manual — Procedure for modifying a template
Page 270 · click to enlarge
Page 270

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

2. Use the Local DTE Rate pop-up menu to select local DTE rate. You have the following choices:

– rate64k(3) – rate640k(12) – rate1280k(22) – rate1856k(32)

– rate128k(4) – rate704k(13) – rate1344k(23) – rate1920k(33)

– rate192k(5) – rate768k(14) – rate1408k(24) – rate1984k(34)

– rate256k(6) – rate832k(15) – rate1472k(25) – rate2048k(35)

– rate320k(7) – rate896k(16) – rate1536k(26) – rate2112k(36)

– rate384k(8) – rate960k(17) – rate1600k(28) – rate2176k(37)

– rate448k(9) – rate1024k(18) – rate1664k(29) – rate2240k(38)

– rate512k(10) – rate1088k(19) – rate1728k(30) – rate2304k(39)

– rate576k(11) – rate1216k(21) – rate1792k(31)

3. Use the Local Clock Mode (Local-Remote) pop-up menu to select the clock mode. You have the following choices:
4. Use the Local Tx Data Sample Point pop-up menu to select the local transmit data sample point. You have the following choices:
5. Use the Remote Tx Data Sample Point pop-up menu to select the remote transmit data sample point. You have the following choices:
6. Configure the Local TM from DTE pop-up menu using the following choices:
7. Configure the Remote TM from DTE pop-up menu using the following choices:
8. Configure the Local Framing Mode pop-up menu using the following choices:
Show 15 more labels / short text on this page
– internal-receiveRecover(0) · – external-receiveRecover(1) · – receiveRecover-internal(2) · – receiveRecover-external(3) · – external-external(4) · – normal(0) · – inverted(1) · – normal(0) · – inverted(1) · – disabled(0) · – enabled(1) · – disabled(0) · – enabled(1) · – slotted(0) · System Config 270
Page 271 of the Patton electronic 1001MC user manual — Deleting a template
Page 271 · click to enlarge
Page 271

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

9. Configure the Remote Framing Mode pop-up menu using the following choices:
10. When you have finished setting the configuration, click on the Submit button to save the changes.

Refer to section “Applying a template” on page 271 to activate the template.

Figure 134. Global Configuration Menu page

Deleting a template Do the following to delete a template:

1. Select a template from the Delete Configuration pop-up menu (see figure 134 ).
2. Click the Delete Configuration button.

Applying a template This section describes how to apply a global configuration to all Model 1095RC rack cards other than those that meet one of the following exceptions:

  • Model 1095RC rack cards installed in Model 1001 racks that have had the Rack Protection Mode option set to protected(1) will not be configured if a global template is applied (see section “Protecting a Model 1001 rack from global configuration” on page 260 for more information.
Show 4 more labels / short text on this page
– normal(3) · – slotted(0) · – normal(3) · System Config 271
Page 272 of the Patton electronic 1001MC user manual — Configure all Model 1095RC rack cards in all Model 1001 racks
Page 272 · click to enlarge
Page 272

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

  • Model 1095RC rack cards that have had the Protected option set to protected(1) will not be configured if a global template is applied (see section “Protecting a Model 1095RC rack card from global configuration” on page 262 for more information.

Select the appropriate option from following configuration choices:

  • Globally configure all Model 1095RC rack cards in all Model 1001 racks (see section “Configure all Model 1095RC rack cards in all Model 1001 racks” on page 272)
  • Globally configure all Model 1095RC rack card in one Model 1001 rack (see section “Configure all Model 1095RC rack cards in one Model 1001 rack” on page 274)

Configure all Model 1095RC rack cards in all Model 1001 racks Do the following to apply global configuration to all Model 1095RC rack cards in all Model 1001 racks:

1. Starting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 135 . Figure 136 shows the web page navigation required to get to this area of the system.

Figure 135. System Level Information page

System Config 272

Page 273 of the Patton electronic 1001MC user manual — Configure all Model 1095RC rack cards in all Model 1001 racks
Page 273 · click to enlarge
Page 273

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Patton electronic 1001MC — Configure all Model 1095RC rack cards in all Model 1001 racks diagram (page 273)
Fig. 125 · Configure all Model 1095RC rack cards in all Model 1…

Figure 136. Web page navigation to System Level Information page

2. Use the Apply System Configuration pop-up menu (see figure 135 ) to select the template you want to apply.
3. Click the Apply Configuration button.

The template has been applied.

System Config 273

Page 274 of the Patton electronic 1001MC user manual — Configure all Model 1095RC rack cards in one Model 1001 rack
Page 274 · click to enlarge
Page 274

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Configure all Model 1095RC rack cards in one Model 1001 rack Do the following to apply global configuration to all Model 1095RC rack cards installed in one Model 1001 rack:

1. Starting from the HOME page, click on the Configure Cards link to display the System Level Information page see figure 137 . Figure 136 on page 273 shows the web page navigation required to get to this area of the system.
Patton electronic 1001MC — Configure all Model 1095RC rack cards in one Model 1001 rack diagram (page 274)
Fig. 126 · Configure all Model 1095RC rack cards in one Model 1…

Figure 137. System Level Information page

2. Locate the rack section of the System Level Information page that you will configure (in figure 137 , Rack 1 Top Level is being modified).
3. Use the Apply Rack Configuration pop-up menu (see figure 137 ) to select the template you want to apply.
4. Click the Apply Configuration button.

The template has been applied.

System Config 274

Page 275 of the Patton electronic 1001MC user manual — Help
Page 275 · click to enlarge
Page 275

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Help

The Help Menu page (see figure 138) provides hyperlinks to help pages located within the 1001MC. Applica- tions notes are also available on the Model 1001MC CD-ROM or by contacting Patton Electronics Technical Support.

Patton electronic 1001MC — Help diagram (page 275)
Fig. 127 · Help

Figure 138. Global Configuration Menu page

The following hyperlinks are available:

  • configuration_info—This link displays information about setting the configuration for the cards in your system. It provides helpful hints to aid in the proper configuration of your system.
  • rack_help—This link displays information about the rack level configuration. It includes information on how to set up each rack for use by the system.
  • system_help—This link displays information about the system level configuration. It includes information on how to set your IP address, IP mask, and Gateway.
  • about—This link displays information about the system including the software revision of the box, total errors, total warning, and tech support contact information.

Help 275

Page 276 of the Patton electronic 1001MC user manual — Table of contents
Page 276 · click to enlarge
Page 276

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 277 of the Patton electronic 1001MC user manual — Troubleshooting the 1001MC rack card
Page 277 · click to enlarge
Page 277

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance

Introduction

This chapter describes troubleshooting and fault analysis that can be performed by the operator. This section contains the following sections to help you troubleshoot the 1001MC rack card and NetLink rack cards:

  • Troubleshooting the 100MC rack card (see page 277 )
  • Troubleshooting network malfunctions (see page 278 )
  • Running test mode diagnostics (see page 282 )
  • Replacing a 1001MC rack card (see page 284 )

If you require more help, refer to chapter 12, “Contacting Patton for assistance” on page 286.

Troubleshooting the 1001MC rack card

Refer to table 15 for 1001MC LED locations and definitions, then refer to table 16 on page 278 for a list of common symptoms and suggested remedies.

Table 15. LED indicators

Patton electronic 1001MC — Troubleshooting the 1001MC rack card diagram (page 277)
Fig. 128 · Troubleshooting the 1001MC rack card

Power Green Power status On = Power is ON Off = Power is OFF LI Green Ethernet: Twisted- pair link indication

On = Connected to active LAN Off = Not connected to active LAN TD Yellow/

Yellow = Idle condition Green = Toggles yellow/green with activity RD Yellow/

Yellow = Idle condition Green = Toggles yellow/green with activity

Toggles when packet TX is on the backplane bus Fault Red Fault condition On = Signals hardware fault Off = No hardware fault

Introduction 277

Page 278 of the Patton electronic 1001MC user manual — Troubleshooting network malfunctions
Page 278 · click to enlarge
Page 278

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance

Table 16. Symptoms and remedies

Power LED (green) is not lit

  • Verify that power is being supplied to the Model 1001MC
  • Verify that at least one chassis power supply module is installed in the 1001 rack chassis and functioning normally
  • Replace the 1001MC (see section “Replacing the Model 1001MC” on page 284)

Fault LED (red) is lit The 1001MC has detected a hardware fault, do the following: TBD.

LI LED (green) is not lit A valid Ethernet link has not been detected, do the following: TBD.

Troubleshooting network malfunctions

Using the Model 1001MC to troubleshoot a network problem generally involves the following steps:

1. Receiving notification that there is a problem.
2. Verifying that the problem exists.
3. Checking the Home , About 1001MC , or System Level Information pages to see if errors or warnings are listed (see section “Checking 1001MC web pages for warnings or errors” ).
4. Reviewing the System Log: Non-Volatile Memory page for information on what may have caused the problem (see section “Using the System Log to check for network problems” on page 282).
5. Checking rack card LEDs to see if one is displaying a fault condition (refer to the user manual that came with each rack card for information on using front-panel LEDs to troubleshoot problems).
6. Performing diagnostics tests with an external analyzer to isolate the problem (see section “1001MC test mode diagnostics” on page 282).

If you require more help, refer to chapter 12, “Contacting Patton for assistance” on page 286.

Checking 1001MC web pages for warnings or errors Do the following:

1. After verifying the existence of a network problem, check one of the following 1001MC web pages to see if errors or warnings are listed:

– Home page (see figure 139 on page 279)

– About 1001MC page (see figure 140 on page 279)

– System Level Information page (see figure 141 on page 280)

2. If no warnings or errors are listed, check rack card front-panel LEDs to see if one is displaying a fault con- dition (refer to the user manual that came with each rack card for information on using front-panel LEDs to troubleshoot problems). Otherwise, (if you are not already at the System Level Information page) go to the HOME page and click on the Configure Cards link to display the System Level Information page. Look at the Top Level rack information for each rack to see if any are also showing warnings or errors (see figure 141 on page 280).

Troubleshooting network malfunctions 278

Problem Corrective Action

Page 279 of the Patton electronic 1001MC user manual — Troubleshooting network malfunctions
Page 279 · click to enlarge
Page 279

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance

3. If no Top Level racks are showing warnings or errors, go to section “Using the System Log to check for net- work problems” on page 282 to review the System Log: Non-Volatile Memory page for information on what may have caused the problem. Otherwise, click on the View Rack X link (where X is the number of the rack showing warnings or errors, in the example shown in figure 141 on page 280, you would click on View Rack 1).

Patton electronic 1001MC — Troubleshooting network malfunctions diagram (page 279)
Fig. 129 · Troubleshooting network malfunctions

Figure 139. Home page displaying warnings and errors

Patton electronic 1001MC — Troubleshooting network malfunctions diagram (page 279)
Fig. 130 · Troubleshooting network malfunctions

Figure 140. About 1001MC page displaying warnings and errors

Troubleshooting network malfunctions 279

Page 280 of the Patton electronic 1001MC user manual — Troubleshooting network malfunctions
Page 280 · click to enlarge
Page 280

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance

Patton electronic 1001MC — Troubleshooting network malfunctions diagram (page 280)
Fig. 131 · Troubleshooting network malfunctions

Figure 141. System Level Information page displaying warnings and errors

Troubleshooting network malfunctions 280

Page 281 of the Patton electronic 1001MC user manual — Troubleshooting network malfunctions
Page 281 · click to enlarge
Page 281

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance

4. Make a note of which rack cards or power supplies are showing errors or warnings (see figure 142 ). Then go to section “Using the System Log to check for network problems” on page 282 to review the System Log: Non-Volatile Memory page for information on what may have caused the problem.
Patton electronic 1001MC — Troubleshooting network malfunctions diagram (page 281)
Fig. 132 · Troubleshooting network malfunctions

Figure 142. Modem Information Rack page displaying errors

Troubleshooting network malfunctions 281

Page 282 of the Patton electronic 1001MC user manual — 1001MC test mode diagnostics
Page 282 · click to enlarge
Page 282

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance

Using the System Log to check for network problems The System Log (see figure 143) is a messaging system that stores information about the system as it is running. Do the following to display the System Log: Non-Volatile Memory page for help in troubleshooting a problem:

1. From the HOME page, click on the System Log, then Non-Volatile Memory... links to display the System Log: Non-Volatile Memory page (see figure 143 ).
Patton electronic 1001MC — Using the System Log to check for network problems diagram (page 282)
Fig. 133 · Using the System Log to check for network problems
Figure 143. System LogNon-Volatile Memory page displaying warnings and errors
2. Examine the page for error or warning are entries (warnings are highlighted in yellow and errors are highlighted in red).

If you are able to determine the cause of the problem by using the System Log, apply appropriate remedies to resolve the situation. (If the remedy includes replacing a NetLink modem, refer to the user manual that came with the rack card for the procedure on replacing the defective rack card.)

Otherwise, check rack card LEDs in the malfunctioning rack to see if one is displaying a fault condition (refer to the user manual that came with each rack card for information on using front-panel LEDs to troubleshoot problems).

If you are still unable to determine the source of the problem, refer to section “1001MC test mode diagnostics” for information on performing diagnostics tests to isolate the problem.

1001MC test mode diagnostics

The Model 1001MC provides the following diagnostics tests and loops that are very helpful when troubleshoot- ing NetLink modems connections:

  • five11 (511)—When this test is applied, it causes the V.52 bit error rate (BER) test pattern generator builtinto the NetLink modem to output (using a mathematical polynomial) a psuedo-random bit pattern of 511 bits. The receiving NetLink modem decodes the received bits using the same polynomial. If the received

1001MC test mode diagnostics 282

Page 283 of the Patton electronic 1001MC user manual — Using the System Log to check for network problems
Page 283 · click to enlarge
Page 283

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance

bits match the agreed aupon pseudo-random pattern, then the NetLink modems and the communication link are functioning properly.

  • five11er (511 with errors)—After successfully concluding a five11 test, use the five11er test (which randomly adds errors to the 511 bit pattern to verify that the receiving modem detects the errors.
  • lal (local loopback)—The local loopback test checks the operation of the local NetLink modem. Any data sent to the local NetLink modem in this test mode will be echoed (returned) back to the originating device (i.e., characters typed on the keyboard of a terminal will appear on the terminal screen) (see figure 144 ).
Patton electronic 1001MC — Using the System Log to check for network problems diagram (page 283)
Fig. 134 · Using the System Log to check for network problems

Figure 144. Local loopback diagram

  • lalWith511 (local loopback with 511)—This test functions the same way as the lal test, but it adds a 511 pattern from the BER generator.
  • lalWith511er (local loopback with 511 and errors)—This test functions the same way as the lalWith511 test, but it adds a 511 pattern from the BER generator that includes errors to verify that the modems can detect the errors.
  • rdl (remote loopback)—The remote loopback test checks the performance of the local and remote NetLink modems. Any data sent to the remote NetLink modem in this test mode will be echoed (returned) back to the originating device (i.e., characters typed on the keyboard of a terminal will appear on the terminal screen) (see figure 145 ).
Patton electronic 1001MC — Using the System Log to check for network problems diagram (page 283)
Fig. 135 · Using the System Log to check for network problems

Figure 145. Remote loopback diagram

  • rdlWith511 (remote loopback with 511)—This test functions the same way as the rdl test, but it adds a 511 pattern from the BER generator.

1001MC test mode diagnostics 283

Page 284 of the Patton electronic 1001MC user manual — Maintenance
Page 284 · click to enlarge
Page 284

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance

  • rdlWith511er (remote loopback with 511 and errors)—This test functions the same way as the rdlWith511 test, but it adds a 511 pattern from the BER generator that includes errors to verify that the modems can detect the errors.

Table 17. Model 1001MC test mode diagnostics supported by NetLink modem rack cards

five11 five11er lal lalWith511 lalWith511er rdl rdlWith511 rdlWith511er

1092ARC ✔ 1094ARC ✔ 1095RC ✔ 2701RC ✔ 2707RC ✔

Running test mode diagnotics Test mode diagnostics can be performed as follows:

  • On the entire system—To test the entire system, go to the System Level Information page and locate the System Overview section. Select the desired test from the Apply System Test Mode pop-up menu, then click on the Apply Test Mode button to initiate the test.
  • On an individual rack—To test a rack, go to the System Level Information page and locate the Top Level rack section for the rack you will be testing. Select the desired test from the Apply Test Mode pop-up menu, then click on the Apply Test Mode button to initiate the test.

Maintenance

Periodic maintenance Consult the rack chassis user manual for information on preventative maintenance (such as cleaning the chassis air cooling vents to remove accumulated dust).

Calibration The Model 1001MC requires no calibration.

Replacing the Model 1001MC If you isolate a problem to the Model 1001MC, replace the front and rear cards as follows.

1. Remove the replacement Model 1001MC front and rear cards from their shipping container and place them near the chassis in which the malfunctioning Model 1001MC is located.

Maintenance 284

Page 285 of the Patton electronic 1001MC user manual — Running test mode diagnotics
Page 285 · click to enlarge
Page 285

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance

2. Disconnect from the malfunctioning Model 1001MC and label the 10Base-T Ethernet cable and RS-232 configuration/daisy-chain cable (if installed).
3. Loosen the captive fasteners located on the front card until it is not longer attached to the rack chassis, when that happens, remove the malfunctioning Model 1001MC by pulling the card gently but firmly from its slot in the chassis. Place the removed card in the container the replacement Model 1001MC came in so you can return the defective Model 1001MC for repair.
4. Loosen the captive fasteners located on the rear card until it is not longer attached to the rack chassis, then remove the card and place it in the container with the front card.
5. Slide the replacement rear I/O card into rear chassis slot 14 along the metal guide rails.
6. Secure the rear card using the captive fasteners.
7. Slide the front rack card into the front chassis slot 14 until it meets the rear card receptacle. When that happens, push the front card gently bur firmly into the card-edge receptacle of the rear card, it should click into place.
8. Secure the front rack card using the captive fasteners.
9. Verify that the green POWER LED on the Model 1001MC front card illuminates.
10. Verify that the LI LED is lit, indicating that the Ethernet connection is nominal.

The Model 1001MC is operational.

Maintenance 285

Page 286 of the Patton electronic 1001MC user manual — Table of contents
Page 286 · click to enlarge
Page 286

Table of contents

Contentsp.3About this guidep.6Audiencep.6Structurep.6Typographical conventions used in this documentp.7General conventionsp.7Mouse conventionsp.8Additional Referencesp.8RFCsp.8Technical supportp.8Servicep.9Chapter 1 Introductionp.10Introductionp.11Model 1001MC management overviewp.14Chapter 2 Hardware installationp.15Introductionp.17Before you install…p.17Checking the contents…p.17Installing the Model 1001MC into the rack chassisp.18Installing NetLink modem cardsp.19Hardware setup for a Model 1092ARCp.19Configuring frame groundp.19Setting the 1092ARC system addressp.20Hardware setup for a Model 1094ARCp.22Configuring frame groundp.22Setting the 1094ARC system addressp.22Hardware setup for a Model 1095RCp.24Configuring frame groundp.24Setting the 1095RC system addressp.24Hardware setup for a Model 2701RCp.26Configuring frame groundp.26Setting the 2701RC system addressp.27Hardware setup for a Model 2707RCp.28Configuring frame groundp.28Hardware setup for a Model 2710RCp.29Configuring frame groundp.29Hardware setup for a Model 2715RCp.29Configuring frame groundp.29Hardware setup for a Model 3088RCp.29Configuring frame groundp.29Setting the 3088RC system addressp.29Installing the power suppliesp.31Verifying 1001MC functioningp.31Connecting the cablesp.32Installing the Ethernet cablep.32Connecting a 10Base-T hub to the 1001MCp.33Connecting a 10Base-T workstation to the 1001MCp.33Installing the RS-232 configuration/daisy-chain port cablep.34LED indicatorsp.34Ethernet LED indicatorsp.35Power LED indicatorp.35Heartbeat LED indicatorp.35Fault LED indicatorp.35PPP LED indicatorp.35Where to go nextp.35Chapter 3 Getting startedp.36Introductionp.37Booting the Model 1001MCp.37Installing the Model 1001MC RS-232 daisy-chain port cablep.39Setting the address range for your NetLink modemsp.40Introduction to the internal HTTP/HTML management pagesp.41Logging into the HTTP/HTML administration pagesp.41HTTP/HTML and SNMP object formatp.42Saving HTTP/HTML object changesp.42Help screensp.42HTTP/HTML web page navigationp.42Homep.44About 1001MCp.44Configure Cardsp.45Downloadp.45System Logp.45SNMPp.45System Configp.45Helpp.45Where to go next…p.46Chapter 4 Model 1092ARC managementp.47Introductionp.49NetLink-NMS descriptionp.49Configuration and managementp.49Displaying the Modem Information pagep.50Displaying the Model 1092 Configuration Slot pagep.52Making configuration changes to your 1092ARC NetLink modemp.53Displaying the Model 1092 Configuration—Next Configuration pagep.54Displaying the Slot Configuration pagep.56Modem Information page MIB variables descriptionp.57Slots Available (totalConfigSlots)p.57Modems Installed (rackXCardsInstalled)p.57Number of Power Supplies (rackXPowerSupplies)p.57Rack Protection Modep.57Submit buttonp.58Power Supply 1 Statusp.58Power Supply 2 Statusp.58Clear Rack X Alarms (clearAlarms)p.58Card Address (nmsSlotID)p.58Line Statusp.58Warnings (warningCount)p.59Errors (errorCount)p.59Local User Id (localUserID)p.59Local Model Code (localModelCode)p.59Remote User Id (remoteUserID)p.59Remote Model Code (remoteModelCode)p.59Protectedp.60Local Circuit ID (localCircuitID)p.60Remote Circuit ID (remoteCircuitID)p.60Submit buttonp.60Model 1092 Configuration Slot page MIB variables descriptionp.61Model 1092A Model 1092 Configuration Slot (nmsSlotID)p.61Line Status (lineStatusiDSL)p.61Processor Mode (processorModeiDSL)p.61Input Mode (mode1092A)p.61Model 1092 Configuration Slot page Configuration Status table descriptionp.62Model Code (localModelCode/remoteModelCode)p.62DTE rate (dteRateiDSL)p.62Clock Mode (Local-Remote)p.62TM From DTE (dteTMiDSL/remotedteTMiDSL)p.62HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL)p.62SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.62Software Rev (softVersioniDSL/remotesoftversioniDSL)p.63Model 1092 Configuration—Next Configuration page MIB variablesdescriptionp.63Card Address (nmsSlotID)p.63Line Status (lineStatusiDSL)p.63Processor Mode (processorModeiDSL)p.63Local Software Rev (softVersioniDSL)p.64Remote Software Rev (remotesoftversioniDSL)p.64Next Configuration tablep.64DTE rate (dteRateiDSL)p.64Clock Mode (Local-Remote)p.64TM From DTE (dteTMiDSL/remotedteTMiDSL)p.64Test Mode (testModeSetiDSL/remotetestModeSetiDSL)p.64Submit Query buttonp.65Clear Changesp.65Set Default Configurationp.65Slot Configuration page MIB variables descriptionp.65Card Address (nmsSlotID)p.65Local Model Code (localModelCode)p.65View Rack X hyperlinkp.65Card Identification Informationp.65Local User Id (localUserID)p.65Remote User Id (remoteUserID)p.65Local Circuit ID (localCircuitID)p.66Remote Circuit ID (remoteCircuitID)p.66Alarm Informationp.66Clear Slot Alarms (resetStatus)p.66Hardware Reset (resetStatus)p.66Card Lost Indication (cardLostIndication)p.66Line Down Indication (lineDownIndication)p.66Chapter 5 Model 1094ARC managementp.67Introductionp.69NetLink-NMS descriptionp.69Configuration and managementp.69Displaying the Modem Information pagep.70Displaying the Model 1094 Configuration Slot pagep.72Making configuration changes to your 1094ARC NetLink modemp.73Displaying the Model 1094 Configuration—Next Configuration pagep.74Displaying the Slot Configuration pagep.76Displaying the Download pagep.77Modem Information page MIB variables descriptionp.78Slots Available (totalConfigSlots)p.78Modems Installed (rackXCardsInstalled)p.78Number of Power Supplies (rackXPowerSupplies)p.78Rack Protection Modep.78Submit buttonp.79Power Supply 1 Statusp.79Power Supply 2 Statusp.79Clear Rack X Alarms (clearAlarms)p.79Card Address (nmsSlotID)p.79Line Statusp.79Warnings (warningCount)p.80Errors (errorCount)p.80Local User Id (localUserID)p.80Local Model Code (localModelCode)p.80Remote User Id (remoteUserID)p.80Remote Model Code (remoteModelCode)p.80Protectedp.81Local Circuit ID (localCircuitID)p.81Remote Circuit ID (remoteCircuitID)p.81Submit buttonp.81Model 1094 Configuration Slot page MIB variables descriptionp.81Model 1094A Model 1094 Configuration Slot (nmsSlotID)p.81Line Status (lineStatus1094)p.82Processor Mode (processorMode1094)p.82Input Mode (mode1094)p.82Model 1094 Configuration Slot page Configuration Status table descriptionp.82Model Code (localModelCode/remoteModelCode)p.83DTE rate (dteRate1094)p.83Clock Mode (Local-Remote)p.83TM From DTE (dteTM1094/remotedteTM1094)p.83HW Test Mode (testModeInd1094/remotetestModeInd1094)p.83SW Test Mode (testModeSet1094/remotetestModeSet1094)p.83Software Rev (softVersion1094/remotesoftversion1094)p.83Model 1094 Configuration—Next Configuration page MIB variablesdescriptionp.84Card Address (nmsSlotID)p.84Line Status (lineStatus1094)p.84Processor Mode (processorMode1094)p.84Local Software Rev (softVersion1094)p.84Remote Software Rev (remotesoftversion1094)p.85Next Configuration tablep.85DTE rate (dteRate1094)p.85Clock Mode (Local-Remote)p.85Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.85TM From DTE (dteTM1094/remotedteTM1094)p.85Test Mode (testModeSet1094/remotetestModeSet1094)p.85Submit Query buttonp.85Clear Changesp.86Set Default Configurationp.86Slot Configuration page MIB variables descriptionp.86Card Address (nmsSlotID)p.86Local Model Code (localModelCode)p.86View Rack X hyperlinkp.86Card Identification Informationp.86Local User Id (localUserID)p.86Remote User Id (remoteUserID)p.86Local Circuit ID (localCircuitID)p.86Remote Circuit ID (remoteCircuitID)p.87Alarm Informationp.87Clear Slot Alarms (resetStatus)p.87Hardware Reset (resetStatus)p.87Card Lost Indication (cardLostIndication)p.87Line Down Indication (lineDownIndication)p.87Using the Download page to upgrade 1094ARC softwarep.87Chapter 6 Model 1095RC managementp.89Introductionp.92NetLink-NMS descriptionp.92Configuration and managementp.92Displaying the Global Configuration Menu pagep.93Displaying the Modem Information pagep.94Displaying the Model 1095 Configuration Slot pagep.95Making configuration changes to your 1095RC NetLink modemp.96Displaying the Model 1095 Configuration—Next Configuration pagep.97Displaying the Slot Configuration pagep.99Displaying the Download pagep.100Modem Information page MIB variables descriptionp.101Slots Available (totalConfigSlots)p.101Modems Installed (rackXCardsInstalled)p.101Number of Power Supplies (rackXPowerSupplies)p.101Rack Protection Modep.101Submit buttonp.102Power Supply 1 Statusp.102Power Supply 2 Statusp.102Clear Rack X Alarms (clearAlarms)p.102Card Address (nmsSlotID)p.102Line Statusp.102Warnings (warningCount)p.103Errors (errorCount)p.103Local User Id (localUserID)p.103Local Model Code (localModelCode)p.103Remote User Id (remoteUserID)p.103Remote Model Code (remoteModelCode)p.103Protectedp.104Local Circuit ID (localCircuitID)p.104Remote Circuit ID (remoteCircuitID)p.104Submit buttonp.104Model 1095 Configuration Slot page MIB variables descriptionp.104Model 1095RC Model 1095 Configuration Slot (nmsSlotID)p.104Line Status (lineStatus1095)p.105Processor Mode (processorMode1095)p.105Previous Card buttonp.105Refresh Current Page buttonp.105Next Card buttonp.105View Rack X hyperlinkp.105Input Mode (mode1095)p.106Model 1095 Configuration Slot page Configuration Status table descriptionp.106Model Code (localModelCode/remoteModelCode)p.106DTE rate (dteRate1095)p.106Clock Mode (Local-Remote)p.106Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.106TM From DTE (dteTM1095/remotedteTM1095)p.107Framing Modep.107HW Test Mode (testModeInd1095/remotetestModeInd1095)p.107SW Test Mode (testModeSet1095/remotetestModeSet1095)p.107Software Rev (softVersion1095/remotesoftversion1095)p.107Model 1095 Configuration—Next Configuration page MIB variablesdescriptionp.107Card Address (nmsSlotID)p.108Line Status (lineStatus1095)p.108Processor Mode (processorMode1095)p.108Local Software Rev (softVersion1095)p.108Remote Software Rev (remotesoftversion1095)p.108Back… hyperlinkp.108Next Configuration tablep.109DTE rate (dteRate1095)p.109Clock Mode (Local-Remote)p.109Tx Data Sample Point (txdEdge1095/remotetxdEdge1095)p.109TM From DTE (dteTM1095/remotedteTM1095)p.109Framing Modep.109Test Mode (testModeSet1095/remotetestModeSet1095)p.110Submit Query buttonp.110Clear Changesp.110Set Default Configurationp.110Slot Configuration page MIB variables descriptionp.110Card Address (nmsSlotID)p.110Local Model Code (localModelCode)p.110View Rack X hyperlinkp.110Card Identification Informationp.110Local User Id (localUserID)p.110Remote User Id (remoteUserID)p.110Local Circuit ID (localCircuitID)p.111Remote Circuit ID (remoteCircuitID)p.111Alarm Informationp.111Clear Slot Alarms (resetStatus)p.111Hardware Reset (resetStatus)p.111Card Lost Indication (cardLostIndication)p.111Line Down Indication (lineDownIndication)p.111Using the Download page to upgrade 1095RC softwarep.111Creating and modifying global configuration templatesp.113Protecting Model 1001 racks and Model 1095RC modems from global modificationp.113Protecting a Model 1001 rack from global configurationp.114Protecting a Model 1095RC rack card from global configurationp.116Creating a templatep.117Configuration rulesp.117Notes on clock mode settingsp.118Notes on framing mode settingsp.118Illegal configuration messagesp.118Procedure for creating a templatep.119Modifying a templatep.121Configuration rulesp.121Notes on clock mode settingsp.122Notes on framing mode settingsp.122Illegal configuration messagesp.122Procedure for modifying a templatep.123Deleting a templatep.125Applying a templatep.125Configure all Model 1095RC rack cards in all Model 1001 racksp.126Configure all Model 1095RC rack cards in one Model 1001 rackp.128Chapter 7 Model 2701RC managementp.129Introductionp.132NetLink-NMS descriptionp.132Configuration and managementp.132Displaying the Modem Information pagep.133Displaying the Model 2701RC Configuration Slot pagep.135Making configuration changes to your 2701RC NetLink NTUp.136Displaying the Model 2701 Configuration pagep.137Displaying the Slot Configuration Pagep.139Modem Information Rack X page MIB variables descriptionp.140Slots Available (totalConfigSlots)p.140Modems Installed (rackXCardsInstalled)p.140Number of Power Supplies (rackXPowerSupplies)p.140Rack Protection Mode (rackXProtected)p.140Submit buttonp.141Power Supply 1 Status (rackXPower1Down)p.141Power Supply 2 Status (rackXPower2Down)p.141Clear Rack X Alarms (clearAlarms)p.141Card Address (nmsSlotID)p.141Line Status (lineStatus)p.141Warnings (warningCount)p.142Errors (errorCount)p.142Local User Id (localUserID)p.142Local Model Code (localModelCode)p.142Remote User Id (remoteUserID)p.142Remote Model Code (remoteModelCode)p.142Protected (disableGlobalConfig)p.143Local Circuit ID (localCircuitID)p.143Remote Circuit ID (remoteCircuitID)p.143Submit buttonp.143Model 2701RC Configuration Slot X page MIB variables descriptionp.143Model 2701RC Configuration Slot (nmsSlotID)p.143Line Status (lineStatus)p.144Alarm countersp.144LOS (losAlarm)p.144AIS (aisAlarm)p.145Flap Count (lineDownCnt)p.145CRC4 Error (crc4Error)p.145The Clear Counter buttonp.145CRC4 Error Alarm Threshold (crc4Threshold)p.146Input Mode (mode2701RC)p.146Model 2701 Configuration Slot page Configuration Status table descriptionp.146Configuration Status (configStatus2701RC)p.146Local Model Code (localModelCode/remoteModelCode)p.146Line Format (lineFormat)p.147Clock Mode (clockMode2701RC)p.147DTE Rate (dteRate2701RC)p.147Line Coding (lineCoding2701RC)p.147CRC4 Framing (crc)p.147CAS Multiframing (casMF)p.147Line Build Out (lineBuildOut)p.147Tx Clock Timing (txClock)p.147SW/HW Test Mode (testModeSetInd)p.147SW Test Mode (testModeSet2701RC)p.148RDL Response (v54Loop)p.148FP Switches (frntSwitch)p.148Pattern Select (patternSelect)p.148Loop Time Out (loopTo)p.148RDL type (rdlType)p.149Configuration Type (configType)p.149TM from DTE (testModeDTE)p.149Software Version (softVersion2701RC)p.149Reset buttonp.149Model 2701 Configuration page MIB variablesdescriptionp.149Line Status (lineStatus2701RC)p.149Software Version (softVersion2701RC)p.149Configuration Type (configType)p.150Channel Assignment (dsoEnableCh1…dsoEnableCh31)p.150Unit Configuration tablep.150Line Format (lineFormat)p.150Clock Mode (clockMode2701RC)p.150DTE Rate (dteRate2701RC)p.150Line Coding (lineCoding2701RC)p.150CRC4 Framing (crc)p.151CAS Multiframing (casMF)p.151Line Build Out (lineBuildOut)p.151Tx Clock Timing (txClock)p.151H/W Test Mode (testModeSetInd)p.151Software Test Mode (testModeSet2701RC)p.152RDL Response(v54Loop)p.152FP Switches (frntSwitch)p.152Pattern Select (patternSelect)p.152Loop Timeout (loopTo)p.152RDL Type (rdlType)p.153Config Type (configType)p.153Test Mode from DTE (testModeDTE)p.153Slot Configuration page MIB variables descriptionp.153Card Address (nmsSlotID)p.153Local Model Code (localModelCode)p.153View Rack X hyperlinkp.153Card Identification Informationp.153Local User Id (localUserID)p.153Remote User Id (remoteUserID)p.154Local Circuit ID (localCircuitID)p.154Remote Circuit ID (remoteCircuitID)p.154Alarm Informationp.154Clear Slot Alarms (resetStatus)p.154Hardware Reset (resetStatus)p.154Card Lost Indication (cardLostIndication)p.154Line Down Indication (lineDownIndication)p.154Creating and modifying global configuration templatesp.155Protecting Model 1001 racks and Model 2701RC NTUs from global modificationp.155Protecting an entire Model 1001 rack from global configurationp.155Protecting a selected Model 2701RC rack card from global configurationp.157Creating a templatep.158Modifying a templatep.163Deleting a templatep.164Applying a templatep.164To configure all Model 2701RC rack cards in all Model 1001 racksp.165To configure all Model 2701RC rack cards in just one Model 1001 rackp.166Chapter 8 Model 2707RC managementp.167Introductionp.169NetLink-NMS descriptionp.169Configuration and managementp.169Displaying the Modem Information pagep.170Displaying the Model 2707RC Configuration Slot pagep.172Making configuration changes to your 2707RC NetLink NTUp.173Displaying the Model 2707RC Configuration—Configuration pagep.174Displaying the Slot Configuration pagep.176Modem Information page MIB variables descriptionp.177Slots Available (totalConfigSlots)p.177Modems Installed (rackXCardsInstalled)p.177Number of Power Supplies (rackXPowerSupplies)p.177Rack Protection Modep.177Submit buttonp.178Power Supply 1 Statusp.178Power Supply 2 Statusp.178Clear Rack X Alarms (clearAlarms)p.178Card Address (nmsSlotID)p.178Line Statusp.178Warnings (warningCount)p.179Errors (errorCount)p.179Local User Id (localUserID)p.179Local Model Code (localModelCode)p.179Remote User Id (remoteUserID)p.179Remote Model Code (remoteModelCode)p.179Protectedp.180Local Circuit ID (localCircuitID)p.180Remote Circuit ID (remoteCircuitID)p.180Submit buttonp.180Model 2707RC Configuration Slot page MIB variables descriptionp.181Model 2707RC Configuration Slot (nmsSlotID)p.181Line Status (lineStatus)p.181Input Mode (mode2707RC)p.181Model 2707RC Configuration Slot X page Configuration Status table descriptionp.181Configuration Status (configStatus2707RC)p.182Model Code (localModelCode/remoteModelCode)p.182Line Format (lineFormat)p.182Clock Mode (clockMode2707RC)p.182DTE rate (dteRate2707RC)p.182Line Coding (lineCoding2707RC)p.182Line Build Out (lineBuildOut)p.182FP Switches (frntSwitch)p.182H/W Test mode (testModeSetInd)p.182S/W Test mode (testModeSet2707RC)p.182Loop Time Out (loopTo)p.183TM from DTE (testModeDTE)p.183Configuration Type (configType)p.183Software Version (softVersion2707RC)p.183Model 2707RC Configuration—Configuration page MIB variablesdescriptionp.183Line Status (lineStatus2707RC)p.183Software Version (softVersion2707RC)p.183Configuration Type (configType)p.183Unit Configuration tablep.184Line Format (lineFormat)p.184Clock Mode (clockMode2707RC)p.184DTE Rate (dteRate2707RC)p.184Line Coding (lineCoding2707RC)p.184Line Build Out (lineBuildOut)p.184FP Switches (frntSwitch)p.184H/W Test mode (testModeSetInd)p.184S/W Test mode (testModeSet2707RC)p.184Loop Timeout (loopTo)p.185Test Mode from DTE (testModeDTE)p.185Config Type (configType)p.185User Id (UserID)p.185Slot Configuration page MIB variables descriptionp.185Card Address (nmsSlotID)p.185Local Model Code (localModelCode)p.185View Rack X hyperlinkp.185Card Identification Informationp.185Local User Id (localUserID)p.185Remote User Id (remoteUserID)p.186Local Circuit ID (localCircuitID)p.186Remote Circuit ID (remoteCircuitID)p.186Alarm Informationp.186Clear Slot Alarms (resetStatus)p.186Hardware Reset (resetStatus)p.186Card Lost Indication (cardLostIndication)p.186Line Down Indication (lineDownIndication)p.186Chapter 9 Model 3088RC managementp.187Introductionp.190NetLink-NMS descriptionp.190Configuration and managementp.190Displaying the Modem Information pagep.191Displaying the Model 3088RC Configuration Slot pagep.193Making configuration changes to your 3088RC NetLink NTUp.194Displaying the Model 3088RC Configuration pagep.195Displaying the Slot Configuration Pagep.197Modem Information Rack X page MIB variables descriptionp.198Slots Available (totalConfigSlots)p.198Modems Installed (rackXCardsInstalled)p.198Number of Power Supplies (rackXPowerSupplies)p.198Rack Protection Mode (rackXProtected)p.198Submit buttonp.199Power Supply 1 Status (rackXPower1Down)p.199Power Supply 2 Status (rackXPower2Down)p.199Clear Rack X Alarms (clearAlarms)p.199Card Address (nmsSlotID)p.199Line Status (lineStatus)p.199Warnings (warningCount)p.200Errors (errorCount)p.200Local User Id (localUserID)p.200Local Model Code (localModelCode)p.200Remote User Id (remoteUserID)p.200Remote Model Code (remoteModelCode)p.200Protected (disableGlobalConfig)p.201Local Circuit ID (localCircuitID)p.201Remote Circuit ID (remoteCircuitID)p.201Submit buttonp.201Model 3088RC Configuration Slot X page MIB variables descriptionp.201Model 3088RC Configuration Slot (nmsSlotID)p.201Line Status (lineStatus)p.202Alarm countersp.202LOS (losAlarm)p.202AIS (aisAlarm)p.203Flap Count (lineDownCnt)p.203CRC4 Error (crc4Error)p.203The Clear Counter buttonp.203CRC4 Error Alarm Threshold (crc4Threshold)p.204Input Mode (mode3088RC)p.204Model 3088RC Configuration Slot page Configuration Status table descriptionp.204Configuration Status (configStatus3088RC)p.204Local Model Code (localModelCode/remoteModelCode)p.204DTE Rate (dteRate3088RC)p.205Clock Mode (clockMode3088RC)p.205TX Clock Invert (tcClockInvert3088RC)p.205DSL Link Enable (dslLinkEnable3088RC)p.205Line Probe (lineProbe3088RC)p.205Annex Type (annexType3088RC)p.205SW Test Mode (testModeSet3088RC)p.205Front Panel Switches (frontPannelSwitches3088RC)p.205Response to Test Mode (responseToTestMode3088RC)p.206Software Version (softVersion3088RC)p.206Reset buttonp.206Model 3088RC Configuration page MIB variablesdescriptionp.206DSL Link State (lineStatus3088)p.206DSL Link State (dSLSyncState3088)p.206Software Version (softVersion3088RC)p.206Configuration Type (configType)p.207Unit Configuration tablep.207Clock Mode (clockMode3088RC)p.207DTE Rate (dteRate3088RC)p.207TX Clock Invert (tcClockInvert3088RC)p.207DSL Link Enable (dslLinkEnable3088RC)p.207Line Probe (lineProbe3088RC)p.207Line Coding (lineCoding3088RC)p.207Line Build Out (lineBuildOut)p.207Tx Clock Timing (txClock)p.208Software Test Mode (testModeSet3088RC)p.209RDL Response(v54Loop)p.209FP Switches (frntSwitch)p.209Slot Configuration page MIB variables descriptionp.209Card Address (nmsSlotID)p.209Local Model Code (localModelCode)p.209View Rack X hyperlinkp.209Card Identification Informationp.209Local User Id (localUserID)p.209Remote User Id (remoteUserID)p.210Local Circuit ID (localCircuitID)p.210Remote Circuit ID (remoteCircuitID)p.210Alarm Informationp.210Clear Slot Alarms (resetStatus)p.210Hardware Reset (resetStatus)p.210Card Lost Indication (cardLostIndication)p.210Line Down Indication (lineDownIndication)p.210Creating and modifying global configuration templatesp.211Protecting Model 1001 racks and Model 3088RC NTUs from global modificationp.211Protecting an entire Model 1001 rack from global configurationp.211Protecting a selected Model 3088RC rack card from global configurationp.213Creating a templatep.214Modifying a templatep.216Deleting a templatep.217Applying a templatep.217To configure all Model 3088RC rack cards in all Model 1001 racksp.217To configure all Model 3088RC rack cards in just one Model 1001 rackp.219Chapter 10 HTTP/HTML web page referencep.220Introductionp.224Loginp.224HOMEp.225About 1001MCp.226Import/Exportp.226Configure Cardsp.226Modem Information Pagep.227System Informationp.227Downloadp.227System Logp.227Syslog—Modifyp.228Syslog—Volatile Memoryp.228Syslog—Non-Volatile Memoryp.228SNMPp.228HOMEp.228Box informationp.228Software Version (boxSoftwareVersion)p.228Software Date Code (boxDateCode)p.228Box Name (boxName)p.229Box Contact (boxContact)p.229Box Location (boxLocation)p.229Running Since Last Boot (boxUpTime)p.229Operating status variablesp.229Total System Slots Available (totalConfigSlots)p.229Total Active Slots (totalActiveSlots)p.229Total System Warnings (boxWarningNumber)p.229Total System Errors (boxErrorNumber)p.229Immediate Actionsp.230About 1001MCp.231Import Exportp.233Export Configurationp.233Import Configurationp.235System Level Informationp.235System Overviewp.235Apply System Configurationp.235Apply System Test Modep.236Total Slots Available (totalConfigSlots)p.236Total Cards Installed (totalActiveSlots)p.236Power Supplies Installed (boxPowerSupplies)p.236Total System Warnings (boxWarningNumber)p.236Total System Errors (boxErrorNumber)p.236Clear All System Alarms (clearAlarms)p.236Rack X Top Levelp.236Rack X Enable (rackXEnable)p.237View Rack X hyperlinkp.237Address Rangep.237Total Slots Available (rackXSlotsAvailable)p.237Total Cards Installed (rackXCardsInstalled)p.237Power Supplies Installed (rackXPowerSupplies)p.237Total Errors (rackXErrorNumber)p.237Total Warnings (rackXWarningNumber)p.237Apply Rack Configurationp.237Apply Test Modep.238Rack Protection Modep.238Clear Rack X Alarms (clearAlarms)p.238Modem Information Rack Xp.239Slots Available (totalConfigSlots)p.239Modems Installed (rackXCardsInstalled)p.239Number of Power Supplies (rackXPowerSupplies)p.239Rack Protection Modep.240Submit buttonp.240Power Supply 1 Statusp.240Power Supply 2 Statusp.240Clear Rack X Alarms (clearAlarms)p.240Card Address (nmsSlotID)p.240Line Statusp.241Warnings (warningCount)p.241Errors (errorCount)p.241Local User Id (localUserID)p.241Local Model Code (localModelCode)p.241Remote User Id (remoteUserID)p.241Remote Model Code (remoteModelCode)p.242Protectedp.242Local Circuit ID (localCircuitID)p.242Remote Circuit ID (remoteCircuitID)p.242Submit buttonp.242Slot Configurationp.243Card Address (nmsSlotID)p.243Local Model Code (localModelCode)p.243View Rack X hyperlinkp.243Card Identification Informationp.243Local User Id (localUserID)p.243Remote User Id (remoteUserID)p.244Local Circuit ID (localCircuitID)p.244Remote Circuit ID (remoteCircuitID)p.244Alarm Informationp.245Clear Slot Alarms (resetStatus)p.245Hardware Reset (resetStatus)p.245Card Lost Indication (cardLostIndication)p.245Line Down Indication (lineDownIndication)p.245System Informationp.246Current System Informationp.246IP Address (boxIpAddress)p.246IP Mask (boxIpMask)p.246Current Gateway (boxGateway)p.246Modifying the IP addressingp.247IP Address (boxIpAddress)p.247IP Mask (boxIpMask)p.247Gateway (boxGateway)p.247Box Contact Informationp.247Box Location (boxLocation)p.247Box Name (boxName)p.247Box Contact (boxContact)p.247SNMP and HTTP Password Informationp.247Superuser Password (boxSnmpMasterPassword)p.247User Password (boxSnmpMonitorPassword)p.248Background Information (boxBackgroundFlag)p.248Web Page Refresh Rate (BoxWebRefreshRate)p.248Web Background Enabled (boxBackgroundFlag)p.249Downloadp.249Upgrading 1001MC software via FTP downloadp.249System Logp.251System Log—Modifyp.252Daemonsp.252Syslog Daemon IP Address (syslogDaemonIP)p.252SNMP Trap Daemon IP Address (syslogTrapIP)p.253Priorityp.253Min Priority for SysLog Daemonp.253Min Priority for Flash Storagep.254Min Priority for RAMp.254Unix Facilityp.255Maintenancep.256Maintain Flash Storage (syslogFlashClear)p.256System Log—Volatile Memoryp.256System Log—Non-Volatile Memoryp.257Erase Flash Messages (syslogFlashClear)p.257SNMPp.258System Configp.259Protecting Model 1001 racks and Model 1095RC modems from global modificationp.259Protecting a Model 1001 rack from global configurationp.260Protecting a Model 1095RC rack card from global configurationp.262Creating a templatep.263Configuration rulesp.263Notes on clock mode settingsp.264Notes on framing mode settingsp.264Illegal configuration messagesp.264Procedure for creating a templatep.265Modifying a templatep.267Configuration rulesp.267Notes on clock mode settingsp.268Notes on framing mode settingsp.268Illegal configuration messagesp.268Procedure for modifying a templatep.269Deleting a templatep.271Applying a templatep.271Configure all Model 1095RC rack cards in all Model 1001 racksp.272Configure all Model 1095RC rack cards in one Model 1001 rackp.274Helpp.275Chapter 11 Troubleshooting and maintenancep.276Introductionp.277Troubleshooting the 1001MC rack cardp.277Troubleshooting network malfunctionsp.278Checking 1001MC web pages for warnings or errorsp.278Using the System Log to check for network problemsp.2821001MC test mode diagnosticsp.282Running test mode diagnoticsp.284Maintenancep.284Periodic maintenancep.284Calibrationp.284Replacing the Model 1001MCp.284Chapter 12 Contacting Patton for assistancep.286Introductionp.287Contact informationp.287Warranty Service and Returned Merchandise Authorizations (RMAs)p.287Warranty coveragep.287Out-of-warranty servicep.287Returns for creditp.287Return for credit policyp.288RMA numbersp.288Shipping instructionsp.288
Page 287 of the Patton electronic 1001MC user manual — Warranty Service and Returned Merchandise Authorizations (RMAs)
Page 287 · click to enlarge
Page 287

Model 1001MC Operations Guide 12 • Contacting Patton for assistance

Introduction

This chapter contains the following information:

  • “Contact information”—describes how to contact Patton technical support for assistance.
  • “Warranty Service and Returned Merchandise Authorizations (RMAs)”—contains information about the RAS warranty and obtaining a return merchandise authorization (RMA).

Contact information

Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.

  • Online support—available at <a href="http://www.patton.com" rel="nofollow noopener" target="_blank">www.patton.com</a> .
  • E-mail support—e-mail sent to support@<a href="http://patton.com" rel="nofollow noopener" target="_blank">patton.com</a> will be answered within 1 business day
  • Telephone support—standard telephone support is available Monday through Friday, from 8:00 A.M. to 5:00 P.M. EST (8:00 to 17:00 UTC-5), Monday through Friday by calling +1 (301) 975-1007

Warranty Service and Returned Merchandise Authorizations (RMAs)

Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship- ment. All of our products are backed by a comprehensive warranty program.

Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod- uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work- manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.

Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or elephants may require replacement.

Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.

Introduction 287

Page 288 of the Patton electronic 1001MC user manual — Return for credit policy
Page 288 · click to enlarge
Page 288

Model 1001MC Operations Guide 12 • Contacting Patton for assistance

Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.

  • 30 to 120 days: We will add a 20% restocking charge (crediting your account with 80% of the purchase price).
  • Over 120 days: Products will be accepted for repairs only.

RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:

  • Completing a request on the RMA Request page in the Support section at <a href="http://www.patton.com" rel="nofollow noopener" target="_blank">www.patton.com</a>
  • By calling +1 (301) 975-1000 and speaking to a Technical Support Engineer
  • By sending an e-mail to returns@<a href="http://patton.com" rel="nofollow noopener" target="_blank">patton.com</a>

All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.

Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:

Patton Electronics Company RMA#xxxx 7622 Rickenbacker Dr. Gaithersburg, MD 20879-4773 USA

Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.

Warranty Service and Returned Merchandise Authorizations (RMAs) 288

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Power LED (green) is not lit• Verify that power is being supplied to the Model 1001MC • Verify that at least one chassis power supply module is installed in the 1001 rack chassis and functioning normally • Replace the 1001MC (see section “Replacing the Model 1001MC” on page 284) p.278
Fault LED (red) is litThe 1001MC has detected a hardware fault, do the following: TBD. p.278
LI LED (green) is not litA valid Ethernet link has not been detected, do the following: TBD. p.278

Ask about the Patton electronic 1001MC

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 1001MC

Be the first to ask — other owners or our team will answer.

Original document

Patton electronic 1001MC manual PDF

288 pages·10.4 MB·Card Game·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…