NetLink™
SNMP Management Card
Operations Guide

Sales Office:
Technical Support:
E-mail:
support@patton.com
Document Number:
022021U Rev. F
Part Number:
Revised:
+1 (301) 975-1000 · +1 (301) 975-1007 · May 19, 2008

Patton Electronics Company, Inc.
7622 Rickenbacker Drive Gaithersburg, MD 20879 USA
Copyright © 2008, Patton Electronics Company. All rights reserved.
are trademarks of Patton Electronics Company. All other trademarks presented in this document are the property of their respective owners.
The information contained in this document is not designed or intended for use as critical components in human life-support systems, equipment used in hazardous environments, or nuclear control systems. Patton Electronics Company disclaims any express or implied warranty of fitness for such uses.
The information in this document is subject to change without notice. Patton Elec- tronics assumes no liability for errors that may appear in this document.
Any software described in this document is furnished under license and may be used or copied only in accordance with the terms of such license.


This guide describes installing and operating a Patton Electronics 1001MC NetLink™ SNMP Management Card. This section describes the following:
This guide is intended for use by qualified systems administrators and network engineers to configure and manage the Patton Electronics Model 1001MC and NetLink™ modems. Knowledge of basic networking con- cepts is assumed
This guide contains the following chapters:

Model 1001MC Operations Guide
This section describes the typographical conventions and terms used in this guide.
The procedures described in this manual use the following text conventions:
Table 1. Text conventions
About this guide · General conventions

Model 1001MC Operations Guide
The following conventions are used when describing mouse actions:
Table 2. Mouse conventions
The Patton Electronics website (www.patton.com) provides 1001MC and NetLink modem application notes, which includes FAQ, startup notes, and test setups.
Use a web browser to find online copies of the following requests for comments (RFC) documents:
Definitions of Managed Objects for the Ethernet-like Interface Types
Structure and Identification of Management Information for TCP/IP-based Internets
Management Information Base for Network Management of TCP/IP-based Internets: MIB-II
RIP Version 2 MIB Extension
Definitions of Managed Objects for the Ethernet-like Interface Types
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.
support@patton.com
will be answered within 1 business day

Model 1001MC Operations Guide
All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Services at:
support@patton.com
Packages received without an RMA number will not be accepted.

Introduction
Introduction 11 Model 1001MC management overview 14
Chapter contents

Model 1001MC Operations Guide
The Model 1001MC NetLink™ SNMP Management Card (see figure 1) enables an SNMP workstation to configure and monitor multiple Patton NetLink cards racks and their connected standalone units.

Figure 1. Model 1001MC NetLink Management Card
The management card has the following features:
- Model 1092ARC KiloModem™ 2 or 4-wire Baseband Modem with 2B1Q Encoding
- Model 1094ARC NetLink 1.152-Mbps HDSL Modem
- Model 1095RC NetLink 2-wire, 2-Mbps mDSL Modem
- Model 2701RC G.703/G.704 Network Termination Unit (NTU)
- Model 2707RC G.703 NTU
- Model 2710RC T1/FT1 CSU/DSU
- Model 2715RC G.703/G.704 NTU
1 • Introduction · Introduction

Model 1001MC Operations Guide
- Model 3088RC G.SHDSL V.35 - M34
- Model 3088RC G.SHDSL X.21 - DB15
- Model 3088RC G.SHDSL E1 - Dual BNC & RJ-45
- Model 3088RC G.SHDSL Ethernet BR - RJ-45
Your specific model of 1001MC may not support all of the models listed above.
The 1001MC front and rear cards (see figure 2) install into the Model 1001R14/16 NetLink Rack Chassis (see figure 3). The rack chassis accepts up to 15 cards and a 90–264 VAC or -12/-24/-48 VDC power supply module (redundant power supply configurations can be created by replacing two rack cards with a second power supply).

Figure 2. Model 1001MC front and rear cards
1 • Introduction · Introduction

Model 1001MC Operations Guide

Figure 3. Model 1001R14/16 Rack Chassis with power supply
1 • Introduction · Introduction

Model 1001MC Operations Guide
The Model 1001MC uses a 10Base-T Ethernet port to connect to a local LAN (or to any location in the world via the Internet). Management can be performed using any SNMP station or web browser with the internal HTTP/HTML management screens. As shown in figure 4, the Model 1001MC can manage multiple racks of Patton NetLink modems using a daisy-chain configuration and a 1001CC in each additionally managed rack.

Figure 4. Network management through a network using a 10Base-T connection to Model 1001MC
Model 1001MC management overview
1 • Introduction



Model 1001MC Operations Guide 2 • Hardware installation
Model 1001MC installation consists of the following:
When you finish installing the 1001MC, go to chapter 3, “Getting started” on page 36.
Before you install… Before installing and configuring your Model 1001MC, make sure you have the following items at hand:
Checking the contents… Verify that the shipping container holds the following items:
Introduction 17

Model 1001MC Operations Guide 2 • Hardware installation

Figure 5. Rack chassis slot layout (rear view)
The Model 1001MC consists of a front rack card and a rear input/output (I/O) card (see figure 2 on page 12). The two cards meet inside the rack chassis and plug into each other by way of mating 50-pin card edge connec- tors. Do the following to install the Model 1001MC cards into the rack chassis:

There are no user-serviceable parts in the power supply section. Voltage set- ting changes and fuse replacement should only be performed by qualified ser- vice personnel. Contact Patton Electronics Technical support at (301) 975-1007 for more information.
Installing the Model 1001MC into the rack chassis 18

Model 1001MC Operations Guide 2 • Hardware installation

Figure 6. Rack chassis slot layout (front view)
This section contains hardware installation information that affects the following NetLink modems:
Hardware setup for a Model 1092ARC The following must be done to configure your Model 1092ARC hardware for use with the Model 1001MC network management station:
When you are finished, install the Model 1092ARC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.
Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 1092ARC rear I/O card must have frame ground (GND) connected to signal GND through a
Installing NetLink modem cards 19

Model 1001MC Operations Guide 2 • Hardware installation
100-ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.
Setting the 1092ARC system address The manual that was shipped with the 1092ARC defines switch S2 as Address. This switch sets the address of the modem in the NetLink system. Each card in the chassis is given a unique address through the setting of switch S2.
Polling overview. The Model 1001MC sends poll messages along the internal bus looking for cards installed in the system. Once a card is found it is placed online and communication with the management station can begin.
If the address of the NetLink modem is not configured or does not match the address range of the rack that it is installed in, the Model 1001MC may not recognize the card. The address range that is polled is determined by the configuration of the system. The system administrator must make sure that the software configuration within the Model 1001MC matches the hardware configuration of the system.
Polling rack #1 and daisy-chained racks. The Model 1001MC uses the number of power supplies in the sys- tem to determine what the address range of the individual racks will be. The number of power supplies installed in each rack is entered on the Modem Information page. If the system is set for two power supplies installed, the 1001MC will automatically set the number of slots available (displayed on the Modem Informa- tion page) in the chassis to 13. If the system is set for a single power supply installed, the 1001MC will auto- matically set the number of slots available in the chassis to 15.
Using this information, the Model 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15
The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. In a redundant power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 14.
The daisy chained racks are set up in the same manner with 13 addresses being available in a redundant system and 15 addresses being available in single supply system. When you disable a rack the addresses are still set aside for that rack space. If a power supply is removed, the addressing will not change unless you make the change through the 1001MC web pages. This allows easy service of the power supplies.
If the address is 0 (all ON position), then the unit will run completely from its DIP-switch configuration. This can be useful for testing circuits independently of the management system. If an address is placed on the switch, the unit will boot from its stored flash configuration and begin looking for poll commands from the Model 1001MC.
Switch S2 allows an 8 bit address to be assigned to a link. The following rules apply to setting the address. Bit S2-8 is the least significant bit. A bit set to ON is considered a 0. A bit set to OFF is considered a 1. Patton Electronics suggests that you set your addresses starting with address 1 at the far left of your rack (farthest away
Installing NetLink modem cards 20

Model 1001MC Operations Guide 2 • Hardware installation
from the power supplies) and increment the numbers by one as you go from left to right. Setting the addresses in this manner will make configuration easier as you start using the web page management. An example of this is shown below.
Table 3 shows the bit setting to configure the address. Table 4 shows examples of address settings.
Table 3. Bit setting to configure the address

0 ON 1 ON ON ON OFF 2 ON ON OFF ON 3 ON ON OFF OFF 4 ON OFF ON ON 5 ON OFF ON OFF 6 ON OFF OFF ON 7 ON OFF OFF ON 8 OFF ON ON ON 9 OFF ON ON OFF A OFF ON OFF ON B OFF ON OFF OFF C OFF OFF ON ON D OFF OFF ON OFF E OFF OFF OFF ON F OFF
Address in Hex (Dec.) S2-7 S2-6 S2-5 S2-4 S2-3 S2-2 S2-1
0x01 (1) ON OFF 0x02 (2) ON OFF ON 0x10 (16) ON ON OFF ON 0x35 (53) ON OFF OFF ON OFF ON OFF
Installing NetLink modem cards 21

Model 1001MC Operations Guide 2 • Hardware installation
Hardware setup for a Model 1094ARC The following must be done to configure your Model 1094ARC hardware for use with the Model 1001MC network management station:
When you are finished, install the Model 1094ARC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.
Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 1094ARC rear I/O card must have frame ground (GND) connected to signal GND through a 100-ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.
Setting the 1094ARC system address The manual that was shipped with the 1094RC defines switch S1 as Address. This switch sets the address of the modem in the NetLink system. Each card in the chassis is given a unique address through the setting of switch S1.
Polling overview. The Model 1001MC sends poll messages along the internal bus looking for cards installed in the system. Once a card is found it is placed online and communication with the management station can begin.
If the address of the NetLink modem is not configured or does not match the address range of the rack that it is installed in, the Model 1001MC may not recognize the card. The address range that is polled is determined by the configuration of the system. The system administrator must make sure that the software configuration within the Model 1001MC matches the hardware configuration of the system.
Polling rack #1 and daisy-chained racks. The Model 1001MC uses the number of power supplies in the sys- tem to determine what the address range of the individual racks will be. The number of power supplies installed in each rack is entered on the Modem Information page. If the system is set for two power supplies installed, the 1001MC will automatically set the number of slots available (displayed on the Modem Informa- tion page) in the chassis to 13. If the system is set for a single power supply installed, the 1001MC will auto- matically set the number of slots available in the chassis to 15.
Using this information, the Model 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15
The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. In a redundant power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from
Installing NetLink modem cards 22

Model 1001MC Operations Guide 2 • Hardware installation
address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 14.
The daisy chained racks are set up in the same manner with 13 addresses being available in a redundant system and 15 addresses being available in single supply system. When you disable a rack the addresses are still set aside for that rack space. If a power supply is removed, the addressing will not change unless you make the change through the 1001MC web pages. This allows easy service of the power supplies.
If the address is 0 (all ON position), then the unit will run completely from its DIP-switch configuration. This can be useful for testing circuits independently of the management system. If an address is placed on the switch, the unit will boot from its stored flash configuration and begin looking for poll commands from the Model 1001MC.
Switch S1 allows an 8 bit address to be assigned to a link. The following rules apply to setting the address. Bit S1-8 is the least significant bit. A bit set to ON is considered a 0. A bit set to OFF is considered a 1. Patton Electronics suggests that you set your addresses starting with address 1 at the far left of your rack (farthest away from the power supplies) and increment the numbers by one as you go from left to right. Setting the addresses in this manner will make configuration easier as you start using the web page management. An example of this is shown below.
Table 5 shows the bit setting to configure the address. Table 6 shows examples of address settings.
Table 5. Bit setting to configure the address
Upper (Lower) Nibble S1-1 (S1-5)
S1-3 (S1-7)
S1-4 (S1-8)
0 ON 1 ON ON ON OFF 2 ON ON OFF ON 3 ON ON OFF OFF 4 ON OFF ON ON 5 ON OFF ON OFF
6 ON OFF OFF ON 7 ON OFF OFF ON 8 OFF ON ON ON 9 OFF ON ON OFF A OFF ON OFF ON B OFF ON OFF OFF C OFF OFF ON ON D OFF OFF ON OFF E OFF OFF OFF ON F OFF
Installing NetLink modem cards 23

Model 1001MC Operations Guide 2 • Hardware installation
Table 6. Examples of address settings
Address in Hex (Dec.) S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 S1-8
0x01 (1) ON OFF 0x02 (2) ON OFF ON 0x10(16) ON ON ON OFF ON 0xB5(181) OFF ON OFF OFF ON OFF ON OFF
Hardware setup for a Model 1095RC The following must be done to configure your Model 1095RC hardware for use with the Model 1001MC net- work management station:
When you are finished, install the Model 1095RC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.
Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 1095RC rear I/O card must have frame ground (GND) connected to signal GND through a 100- ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.
Setting the 1095RC system address The manual that was shipped with the 1095RC defines switch S1 as Address. This switch sets the address of the modem in the NetLink system. Each card in the chassis is given a unique address through the setting of switch S1.
Polling overview. The Model 1001MC sends poll messages along the internal bus looking for cards installed in the system. Once a card is found it is placed online and communication with the management station can begin.
If the address of the NetLink modem is not configured or does not match the address range of the rack that it is installed in, the Model 1001MC may not recognize the card. The address range that is polled is determined by the configuration of the system. The system administrator must make sure that the software configuration within the Model 1001MC matches the hardware configuration of the system.
Polling rack #1 and daisy-chained racks. The Model 1001MC uses the number of power supplies in the sys- tem to determine what the address range of the individual racks will be. The number of power supplies installed in each rack is entered on the Modem Information page. If the system is set for two power supplies installed, the 1001MC will automatically set the number of slots available (displayed on the Modem Informa- tion page) in the chassis to 13. If the system is set for a single power supply installed, the 1001MC will auto- matically set the number of slots available in the chassis to 15.
Installing NetLink modem cards 24

Model 1001MC Operations Guide 2 • Hardware installation
Using this information, the Model 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15
The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. In a redundant power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 14.
The daisy chained racks are set up in the same manner with 13 addresses being available in a redundant system and 15 addresses being available in single supply system. When you disable a rack the addresses are still set aside for that rack space. If a power supply is removed, the addressing will not change unless you make the change through the 1001MC web pages. This allows easy service of the power supplies.
If the address is 0 (all ON position), then the unit will run completely from its DIP-switch configuration. This can be useful for testing circuits independently of the management system. If an address is placed on the switch, the unit will boot from its stored flash configuration and begin looking for poll commands from the Model 1001MC.
Switch S1 allows an 8 bit address to be assigned to a link. The following rules apply to setting the address. Bit S1-8 is the least significant bit. A bit set to ON is considered a 0. A bit set to OFF is considered a 1. Patton Electronics suggests that you set your addresses starting with address 1 at the far left of your rack (farthest away from the power supplies) and increment the numbers by one as you go from left to right. Setting the addresses in this manner will make configuration easier as you start using the web page management. An example of this is shown below.
Installing NetLink modem cards 25

Model 1001MC Operations Guide 2 • Hardware installation
Table 7 shows the bit setting to configure the address. Table 8 shows examples of address settings.
Table 7. Bit setting to configure the address

0 ON 1 ON ON ON OFF 2 ON ON OFF ON 3 ON ON OFF OFF 4 ON OFF ON ON 5 ON OFF ON OFF 6 ON OFF OFF ON 7 ON OFF OFF ON 8 OFF ON ON ON 9 OFF ON ON OFF A OFF ON OFF ON B OFF ON OFF OFF C OFF OFF ON ON D OFF OFF ON OFF E OFF OFF OFF ON F OFF
Address in Hex (Dec.) S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 S1-8
0x01 (1) ON OFF 0x02 (2) ON OFF ON 0x10(16) ON ON ON OFF ON 0xB5(181) OFF ON OFF OFF ON OFF ON OFF
Hardware setup for a Model 2701RC The following must be done to configure your Model 2701RC hardware for use with the Model 1001MC net- work management station:
When you are finished, install the Model 2701RC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.
Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 2701RC rear I/O card must have frame ground (GND) connected to signal GND through a 100- ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.
Installing NetLink modem cards 26

Model 1001MC Operations Guide 2 • Hardware installation
Setting the 2701RC system address The manual that was shipped with your NetLink-E1 unit specifies switch S3 for the card address in the NetLink System. Each card in the chassis is given a unique address through the setting of switch S3.
Polling overview. The Model 1001MC sends “poll” messages along the internal bus looking for cards installed in the system. Once a card is found it is placed “online” and communication with the management station can begin.
If the address of the NetLink modem is not configured or does not match the address range of the rack that it is installed in, the Model 1001MC may not recognize the card. The address range that is polled is determined by the configuration of the system. The system administrator must make sure that the software configuration within the Model 1001MC matches the hardware configuration of the system.
Polling rack #1 and daisy-chained racks. The Model 1001MC uses the number of power supplies in the sys- tem to determine what the address range of the individual racks will be. The number of power supplies installed in each rack is entered on the Modem Information page. If the system is set for two power supplies installed, the 1001MC will automatically set the number of slots available (displayed on the Modem Informa- tion page) in the chassis to 13. If the system is set for a single power supply installed, the 1001MC will auto- matically set the number of slots available in the chassis to 15.
Using this information, the Model 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15
The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. In a redundant power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 14.
The daisy chained racks are set up in the same manner with 13 addresses being available in a redundant system and 15 addresses being available in single supply system. When you disable a rack the addresses are still set aside for that rack space. If a power supply is removed, the addressing will not change unless you make the change through the 1001MC web pages. This allows easy service of the power supplies.
The 2701RCs are shipped to use DIP switch configuration as default. Software configuration can be enabled through either the VT-100 screens or through the 1001MC NMS. To use the NMS, switch S2-7 must be set to the “OFF” position, otherwise the VT-100 port is active.
Switch S3 allows a decimal address to be assigned to a link. The following rules apply to setting the address:
Installing NetLink modem cards 27

Model 1001MC Operations Guide 2 • Hardware installation
Figure 7 shows the bit setting to configure the address. Table 9 shows examples of address settings.

Figure 7. Bit setting to configure the address
Table 9. Examples of address settings

Hex Address (Decimal Address) S3-8 S3-7 S3-6 S3-5 S3-4 S3-3 S3-2 S3-1
0x01 (1) ON OFF 0x02 (2) ON OFF ON 0x10(16) ON ON ON OFF ON 0xB5(181) OFF ON OFF OFF ON OFF ON OFF
Hardware setup for a Model 2707RC The following must be done to configure your Model 2707RC hardware for use with the Model 1001MC net- work management station:
When you are finished, install the Model 2707RC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.
Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 2707RC rear I/O card must have frame ground (GND) connected to signal GND through a 100- ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.
Installing NetLink modem cards 28

Model 1001MC Operations Guide 2 • Hardware installation
Hardware setup for a Model 2710RC The following must be done to configure your Model 2710RC hardware for use with the Model 1001MC net- work management station:
When you are finished, install the Model 2710RC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.
Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 2710RC rear I/O card must have frame ground (GND) connected to signal GND through a 100- ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.
Hardware setup for a Model 2715RC The following must be done to configure your Model 2715RC hardware for use with the Model 1001MC net- work management station:
When you are finished, install the Model 2715RC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.
Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 2715RC rear I/O card must have frame ground (GND) connected to signal GND through a 100- ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.
Hardware setup for a Model 3088RC The following must be done to configure your Model 3088RC hardware for use with the Model 1001MC net- work management station:
When you are finished, install the Model 3088RC front card and rear I/O card using the installation proce- dures in the manual that came with the modem.
Configuring frame ground The Model 1001MC uses an internal bus to communicate with the NetLink modems installed in your system. The Model 3088RC rear I/O card must have frame ground (GND) connected to signal GND through a 100- ohm resistor. This is done by configuring a jumper on the modem’s rear I/O card. Refer to the installation manual that came with the rack card for more information on this jumper setting.
Setting the 3088RC system address The manual that was shipped with your NetLink-E1 unit specifies switch S3 for the card address in the NetLink System. Each card in the chassis is given a unique address through the setting of switch S3.
Installing NetLink modem cards 29

Model 1001MC Operations Guide 2 • Hardware installation
Polling overview. The Model 1001MC sends “poll” messages along the internal bus looking for cards installed in the system. Once a card is found it is placed “online” and communication with the management station can begin.
If the address of the NetLink modem is not configured or does not match the address range of the rack that it is installed in, the Model 1001MC may not recognize the card. The address range that is polled is determined by the configuration of the system. The system administrator must make sure that the software configuration within the Model 1001MC matches the hardware configuration of the system.
Polling rack #1 and daisy-chained racks. The Model 1001MC uses the number of power supplies in the sys- tem to determine what the address range of the individual racks will be. The number of power supplies installed in each rack is entered on the Modem Information page. If the system is set for two power supplies installed, the 1001MC will automatically set the number of slots available (displayed on the Modem Informa- tion page) in the chassis to 13. If the system is set for a single power supply installed, the 1001MC will auto- matically set the number of slots available in the chassis to 15.
Using this information, the Model 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15
The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. In a redundant power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 14.
The daisy chained racks are set up in the same manner with 13 addresses being available in a redundant system and 15 addresses being available in single supply system. When you disable a rack the addresses are still set aside for that rack space. If a power supply is removed, the addressing will not change unless you make the change through the 1001MC web pages. This allows easy service of the power supplies.
Switch S3 allows a decimal address to be assigned to a link. The following rules apply to setting the address:
Installing NetLink modem cards 30

Model 1001MC Operations Guide 2 • Hardware installation
Figure 7 shows the bit setting to configure the address. Table 9 shows examples of address settings.

Figure 8. Bit setting to configure the address
Table 10. Examples of address settings

Hex Address (Decimal Address) S3-8 S3-7 S3-6 S3-5 S3-4 S3-3 S3-2 S3-1
0x01 (1) ON OFF 0x02 (2) ON OFF ON 0x10(16) ON ON ON OFF ON 0xB5(181) OFF ON OFF OFF ON OFF ON OFF
Refer to the installation manual that came with the power supply (or supplies) to install the supply and rear power entry module into the rack chassis.
Installing the power supplies 31

Model 1001MC Operations Guide 2 • Hardware installation
Installing 1001MC rear I/O card cables takes place in the following order:

Do not work on the system or connect or disconnect cables during periods of lightning activity.

Figure 9. Rear I/O card ports
Installing the Ethernet cable The RJ-45 Ethernet jack on the rear I/O card of the Model 1001MC is designed to connect directly to a 10Base-T network. Figure 10 shows the RJ-45 jack pin-out diagram. Refer to the following sections when con- structing Ethernet cables to connect to the Patton Model 1001MC.

Figure 10. 1001MC 10Base-T Ethernet port pin-out diagram
Connecting the cables 32

Model 1001MC Operations Guide 2 • Hardware installation
Connecting a 10Base-T hub to the 1001MC The Ethernet 10Base-T port on the rear of the 1001MC connects directly to a 10Base-T hub or repeater using RJ-45 unshielded twisted-pair cable that is wired straight-through (see figure 11).

Figure 11. Hub wiring diagram
Connecting a 10Base-T workstation to the 1001MC The 10Base-T port on the 1001MC connected to a workstation by means of a cross-connect cable. Refer to figure 12 to build a cross-connect cable that connects between the 10Base-T port on a workstation’s NIC and the 1001MC’s 10Base-T port.

Figure 12. Workstation wiring diagram
Connecting the cables 33

Model 1001MC Operations Guide 2 • Hardware installation
Installing the RS-232 configuration/daisy-chain port cable The DB-25 connector is a DTE-configured RS-232 port that is used to set up your IP address, subnet mask, and default configuration. After the system is set up, the configuration port can be used to connect to a Model 1001CC in a separate rack if you are daisy-chaining multiple racks.

Figure 13. RS-232 DTE configuration port
Using personal computer communications software (Procomm, Windows Terminal, BitCom, PC Anywhere, etc.), set the configuration of your communications software to the following parameters:
The 1001MC front card has status LEDs (see figure 14) that display at-a-glance the current operational status of the 1001MC.

Figure 14. Front card LEDs
LED indicators 34

Model 1001MC Operations Guide 2 • Hardware installation
Ethernet LED indicators The Ethernet LEDs convey transmit and receive data activity as well as the status of the link (see table 11).
Table 11. Ethernet LED indicators
LED Color Function Description
LI Green Twisted pair link indication On = Connected to active LAN Off = Not connected to active LAN TD Yellow/Green Transmit data from 1001MC
Yellow = Idle condition Green = Toggles yellow/green with activity RD Yellow/Green Receive data at 1001MC from LAN Yellow = Idle condition
Green = Toggles yellow/green with activity
Power LED indicator The power LED shows the power status of the Model 1001MC (see table 12).
Table 12. Power LED indicator
LED Color Function Description
Power Green Power status On = Power is ON Off = Power is OFF
Table 13. Poll LED indicator
LED Color Function Description
Poll Yellow Heartbeat Toggles when packet TX is on the backplane bus
Table 14. Fault LED indicator
LED Color Function Description
Fault Red Fault condition On = Signals hardware fault Off = No hardware fault
Congratulations, you have finished installing the Model 1001MC! Now go to chapter 3, “Getting started” on page 36.
Where to go next 35


Model 1001MC Operations Guide 3 • Getting started
To complete this section you will need the following:
DRAM:Configure Complete
FLASH:Configure Complete
Boot Version May 11 1999 14:44:24
Valid operational code, Hit ‘b’ three times to stop operational boot
Validating operation code · Introduction 37

Model 1001MC Operations Guide 3 • Getting started
Timer Started May 11 1999 14:44:24
Mask:255.255.255.0
Gateway:209.49.110.1
Change IP settings (y/n)?
Mask:255.255.255.0
Gateway:209.49.110.1
Change IP settings (y/n)? y
User Set IP:209.49.110.188
User Set Mask:255.255.255.0
User Set Gateway:209.49.110.1
Mask:255.255.255.0
Gateway:209.49.110.1
Save these settings (y/n)? Y
Current Hardware Revision B
Change Hardware Revision (y/n)? n
Booting the Model 1001MC 38

Model 1001MC Operations Guide 3 • Getting started
Are you sure you want to erase current configuration (y/n)?y
If y is entered, the current configuration will be erased and the factory default configuration will be restored.
Are you sure you want to erase current configuration (y/n)?n
If n is entered, the boot sequence will continue without any changes to configuration.
Using the Model 1001MC RS-232 Daisy Chain Port and an EIA-510 cable, your Model 1001MC can man- age up to seven additional racks. Each daisy chained rack must have a Model 1001CC Controller Card installed. The Model 1001MC—in combination with the Model 1001CC—can control up to 120 NetLink rack card modems and their remote CPE devices. This section describes how to connect your Model 1001MC to additional racks.
Installing the Model 1001MC RS-232 daisy-chain port cable 39

Model 1001MC Operations Guide 3 • Getting started

Figure 15. Configuring a daisy-chain network
Setting the address range for your NetLink modems The Model 1001MC polls the system looking for NetLink modems. If the address of the NetLink modem is not configured or does not match the rack that it is installed in, the Model 1001MC may not find the card. The address range that is polled is determined by the configuration of the system. The system administrator must make sure that the software configuration within the Model 1001MC matches the hardware configura- tion of the system.
The Model 1001MC uses the number of power supplies in the system to determine what the address range of the individual racks will be. The number of power supplies installed in each rack is entered on the Modem Information page. If the system is set for two power supplies installed, the 1001MC will automatically set the number of slots available (displayed on the Modem Information page) in the chassis to 13. If the system is set for a single power supply installed, the 1001MC will automatically set the number of slots available in the chassis to 15.
Using this information, the Model 1001MC will poll the specified address range in each rack. Thus, in a single power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 15
Installing the Model 1001MC RS-232 daisy-chain port cable 40

Model 1001MC Operations Guide 3 • Getting started
The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 16. in a redundant power supply system, the address range for rack #1 (the rack with the 1001MC installed) will be from address 1 to address 13. The 1001MC will then begin polling rack #2 on the daisy chain port starting from address 14.
The daisy-chained racks are setup in the same manner with 13 addresses being available in a redundant system and 15 addresses being available in single supply system. When you disable a rack the addresses are still set aside for that rack space. If a power supply is removed, the addressing will not change unless you make the change through the 1001MC web pages. This allows easy service of the power supplies.
This section explains how to configure the internal HTTP/HTML management pages to manage your Patton NetLink System. The system can also be managed by using an SNMP Network Management Station using a standard SNMP software package or MIB walking tool.
Logging into the HTTP/HTML administration pages To log into the HTTP/HTML administration pages, you must enter the 4-octet Internet protocol (IP) address—in the format http://your.server.ip.address (for example, http://201.168.15.12)—as the universal resource locator (URL) into a World-Wide Web (WWW) browser. After you enter the IP address, the 1001MC will prompt for your user name and password as shown in figure 16.

Figure 16. 1001MC login window
The Model 1001MC has two levels of password protection:
Introduction to the internal HTTP/HTML management pages 41

Model 1001MC Operations Guide 3 • Getting started
HTTP/HTML and SNMP object format In this document, we shall describe the variables found on each of the internal HTTP/HTML pages. This description will include brief definitions of the Patton Enterprise MIB or SNMP MIB II object identifiers wherever applicable. The format of the variables will resemble figure 17.

Figure 17. HTTP/HTML and SNMP object format
Sometimes you will need to save changes that you have made in the HTTP/HTML pages. Do the following to make changes to read/write variables:
Help screens The Model 1001MC web pages have built-in help screens that enable you to get information about the vari- ables that are being described. Each web page contains several headings that describe the section that is being defined. Some of the headings are hyperlinks to the help screen for that page. The new window will automati- cally scroll to the help area that was requested. You may also scroll through this page to view help information about other sections of the page. In some cases, the headings for the tables will be shown as hyperlinks, these hyperlinks, work the same as was previously discussed, showing the help screen for that column of the table.
HTTP/HTML web page navigation This section describes how to navigate the internal HTTP/HTML web pages on the Model 1001MC. The diagram below shows how all of the web pages are linked together. Following figure 18, there is a brief descrip- tion of each page. For more detailed information about each web page, refer to chapter 10, “HTTP/HTML web page reference” on page 220.
Saving HTTP/HTML object changes 42

Model 1001MC Operations Guide 3 • Getting started

Figure 18. 1001MC command map
Saving HTTP/HTML object changes 43

Model 1001MC Operations Guide 3 • Getting started
After logging in, the system displays the HOME page (see figure 19).

Figure 19. HOME page
Home The HOME page displays a quick overview of the system including; error and warning indications, software information, box names, number of modems installed, and so on.
On the left side of the HOME page is the Navigation View. The list on the left side of the screen allows you to navigate to any page from this point. The navigation page will always be available to you so you can change from one page to the next.
The Record Current Configuration button lets you store configuration changes made to the box.
The Hard Reset button forces the 1001MC to perform a reset. This will not reset the individual cards in the rack only the 1001MC. If you would like to perform a hardware reset on the individual cards, refer to the Slot Configuration page. For more information, refer to section “HOME” on page 228.
About 1001MC The About 1001MC page gives a more in-depth overview of the system that presented on the HOME page. This page also provides contact information about Patton Electronics. For more information, refer to section “About 1001MC” on page 231.
Saving HTTP/HTML object changes 44

Model 1001MC Operations Guide 3 • Getting started
Configure Cards Clicking on the Configure Cards hyperlink displays the System Level Information page. This page is the starting point for the configuration and management of your Patton NetLink modems. This page enables you to quickly identify potential problems and view statistics on a per-rack basis. You can also disable racks from this level. For more information, refer to section “” on page 249.
The Download page enables you to perform software upgrades on the NetLink rack card modems installed in the system. New software for the modems can be obtained from Patton Electronics and uploaded into the 1001MC system via a file-transfer protocol (FTP) connection. For more information, refer to section “Down- load” on page 249.
System Log The System Log page displays Syslog messages. Syslog messaging is a reporting tool used in the Model 1001MC to log run-time operations. There are several levels of messages and you can set the system to report only messages above a certain level. For more information, refer to section “System Log” on page 251.
SNMP The SNMP web page enables you to download the Patton Enterprise MIBs for the Model 1001MC. These MIBs are required if you plan to manage the system using a network management station (NMS) instead of the web page manager. For more information, refer to section “SNMP” on page 258.
System Config The System Config web page is where Model 1095RC rack cards can be configured globally by templates you create. If you use this capability, you have the option to globally configure some or all Model 1095RC modems in multiple racks, or those in just one rack. For more information, refer to section “System Config” on page 259.
Help The Help Menu page provides hyperlinks to help pages located within the 1001MC. For more information, refer to section “Help” on page 275.
Saving HTTP/HTML object changes 45
Download

Model 1001MC Operations Guide 3 • Getting started
Refer to the following chapters as appropriate to manage the modem rack cards installed in your Model 1001 rack chassis:
For more detailed information about Model 1001MC management web pages, refer to chapter 10, “HTTP/HTML web page reference” on page 220.
Where to go next… 46



Model 1001MC Operations Guide 4 • Model 1092ARC management
This chapter describes managing a Model 1092ARC NetLink iDSL modem using the Model 1001MC NetLink-NMS internal HTTP/HTML web engine and a standard web browser. This chapter is meant to be used in addition to the manual that came with your unit.
NetLink-NMS description Specifically designed for use in the Patton NetLink system, when the NetLink iDSL is coupled with the Model 1001MC NetLink-NMS and the Patton Model 1001 rack system, the modem is fully SNMP manageable. SNMP management can be performed on both the local and remote units using a standard SNMP network man- agement station (NMS) or by using a standard web browser and the Model 1001MC’s built-in web server. You can view and change configuration variables, view statistical variables, and view error and warning indications.
This section describes the configuration and management of your NetLink iDSL modems using a Model 1001MC NetLink-NMS with built in HTTP/HTML web server. If you plan to manage your units using a standard network management station you can download the Patton Enterprise MIBs either through the SNMP web page on the Model 1001MC or obtain them from the Patton web site at www.patton.com.
The following pages are used to configure and manage the Model 1092ARC:
Introduction 49

Model 1001MC Operations Guide 4 • Model 1092ARC management
Displaying the Modem Information page The Modem Information page (see figure 20) displays the cards installed in the system and a quick view of any errors or warnings associated with your modems.

Figure 20. Modem Information page for the Model 1092ARC
Starting from the HOME page, to access the Modem Information page for the 1092ARC, click on the following links: Configure Cards > View Rack 1. Figure 21 on page 51 shows the web page navigation required to get to this area of the system. For more information about items on the Modem Information page, see “Displaying the Slot Configuration page” on page 56.
Configuration and management 50

Model 1001MC Operations Guide 4 • Model 1092ARC management

Figure 21. Web page navigation to Modem Information page
Configuration and management 51

Model 1001MC Operations Guide 4 • Model 1092ARC management
Displaying the Model 1092 Configuration Slot page The Model 1092 Configuration Slot page (see figure 22) enables you to make configuration changes to the Model 1092A and the remote CPE box. When the page displays, the unit is set to the onLine state and the cur- rent configuration is displayed.

Figure 22. Model 1092 Configuration Slot page
Starting from the HOME page, to access the Model 1092 Configuration Slot page for the 1092ARC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 1092ARC you wish to manage (in the example shown in figure 22, the 1092ARC was installed in slot 11). Figure 23 on page 53 shows the web page navigation required to get to this area of the system.
Configuration and management 52

Model 1001MC Operations Guide 4 • Model 1092ARC management

Figure 23. Web page navigation to Model 1092 Configuration Slot page
Making configuration changes to your 1092ARC NetLink modem Do use the following to make configuration changes to your NetLink modem.
For more information about items on the Model 1092 Configuration Slot page, see “Model 1092 Configura- tion Slot page MIB variables description” on page 61.
Configuration and management 53

Model 1001MC Operations Guide 4 • Model 1092ARC management
Displaying the Model 1092 Configuration—Next Configuration page The Model 1092 Configuration—Next Configuration page (see figure 24) enables you to make configuration changes to the Model 1092A and the remote CPE box. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Figure 24. Model 1092 Configuration—Next Configuration page
Starting from the HOME page, to access the Model 1092 Configuration—Next Configuration page for the 1092ARC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 1092ARC you wish to manage > Modify Configuration (you first have to change input mode from onLine to superVisory- Mode. Figure 25 on page 55 shows the web page navigation required to get to this area of the system.
For more information about items on the Model 1092 Configuration—Next Configuration page, see “Model 1092 Configuration—Next Configuration page MIB variables description” on page 63.
Configuration and management 54

Model 1001MC Operations Guide 4 • Model 1092ARC management

Figure 25. Web page navigation to Model 1092 Configuration—Next Configuration page
Configuration and management 55

Model 1001MC Operations Guide 4 • Model 1092ARC management
Displaying the Slot Configuration page The Slot Configuration page (see figure 26) is used to set slot-specific information related to the system and how the system treats that slot in the case of errors or warnings.

Figure 26. Slot Configuration page
Starting from the HOME page, to access the Slot Configuration page for the 1092ARC, click on the following links: Configure Cards > View Rack 1 > Card_Address for the 1092ARC you wish to manage (in the example shown in figure 26, the 1092ARC was installed in slot 1). Figure 27 on page 57 shows the web page navigation required to get to this area of the system.
Configuration and management 56

Model 1001MC Operations Guide 4 • Model 1092ARC management

Figure 27. Web page navigation to Slot Configuration page
For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description” on page 65.
This section describes the MIB variables that are available on the Modem Information page.
Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.
Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.
Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.
If you want to protect all Model 1095RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the pop-up menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.
Modem Information page MIB variables description 57
Rack Protection Mode

Model 1001MC Operations Guide 4 • Model 1092ARC management
Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.
Power Supply 1 Status Displays the current status of power supply 1 as one of the following:
Power Supply 2 Status Displays the current status of power supply 2 as one of the following:
Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.
Card Address (nmsSlotID) This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the Model 1092ARC Configuration Slot page. This page can be used to set slot-specific information about the card.
Line Status The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:
Modem Information page MIB variables description 58

Model 1001MC Operations Guide 4 • Model 1092ARC management
Warnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more infor- mation on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warning for the slot can be erased in the Slot Configuration page.
Errors (errorCount) This field displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page.
Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.
Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration page for the NetLink modem and its remote unit. The model code information is passed to the Model 1001MC after the card is placed online. The Model 1001MC is auto- sensing, meaning that when a card is found or lost, the information will automatically be updated in the sys- tem. You are not required to setup the Model Code information for each slot. When a card is removed from the system, the Model Code will be erased and an error or warning will be displayed for the slot (this depends on the settings in the Slot Configuration page)
Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, you ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.
Remote Model Code (remoteModelCode) This column displays the model code of the Customer Premise NetLink modem at the far end of the link. This information is communicated from the CP box over the link to the CO Rack Card unit. The NetLink mDSL
Modem Information page MIB variables description 59

Model 1001MC Operations Guide 4 • Model 1092ARC management
rack card will then update the Model 1001MC. For this reason this information will not be available until after the link is made between the two modems.
You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed within the Configure Cards page or from the Slot Configuration page. After clicking the Sub- mit Query button to input the string to the management system, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards web page or from the Slot Configuration page.
Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
Modem Information page MIB variables description 60
Protected

Model 1001MC Operations Guide 4 • Model 1092ARC management
This section describes the MIB variables that are available on the Model 1092 Configuration Slot page.
Model 1092A Model 1092 Configuration Slot (nmsSlotID) Displays the address of the NetLink iDSL modem. The address is defined by the DIP-switch setting of S1 on the rack card. The remote standalone unit has no address specified, but uses that address of the rack card that it is connected to.
Line Status (lineStatusiDSL) Displays the status of the line. There are three possible values that can be displayed:
When the line status is dataMode(2), the units are linked-up and ready to send data.
Processor Mode (processorModeiDSL) Displays the status of the processor running on the NetLink-iDSL. There are four values that are significant to you:
At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the NetLink-iDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set- ting of the card.
Input Mode (mode1092A) The following settings are available:
To make configuration changes to the NetLink-iDSL modems, you must first set this bit to superVisoryMode1). When the Input Mode is set to superVisoryMode1), the Modify Configuration hyperlink will appear on the web page next to the Refresh Current Page hyperlink. Select the Modify Configuration hyperlink. The Model 1092A Configuration—Next Configuration page will appear (see section “Model 1092 Configuration—Next Configuration page MIB variables description” on page 63 for more information). After making configuration changes to the NetLink-iDSL modems in the Model 1092A Update Configuration page, return to this page and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has completed and will cause it to copy the new configuration into the NetLink-iDSL
Model 1092 Configuration Slot page MIB variables description 61

Model 1001MC Operations Guide 4 • Model 1092ARC management
configuration space. If this is not done, the NetLink-iDSL will not recognize the configuration changes that were made.
Model 1092 Configuration Slot page Configuration Status table description The Configuration Status table shows the configuration for the set of units. There are columns for the local and remote units. If a field is highlighted in yellow, it signifies one of two possible conditions:
The following sections define the MIB variables that are shown in the Configuration Status table.
Model Code (localModelCode/remoteModelCode) These variables display the local and remote models codes for the units that were found in the specified address.
DTE rate (dteRateiDSL) This variable displays the DTE rate for the link. Because the NetLink-iDSL modems are symmetrical (same rate in both direction), there is only one MIB variable that defines the DTE rate.
Clock Mode (Local-Remote) This variable defines the clock mode for the NetLink modems. The display shows the Local clock mode (rack card) and then the remote clock mode.
TM From DTE (dteTMiDSL/remotedteTMiDSL) These MIB variables define whether you would like the modems to accept test mode requests from the DTE that is connected. In normal applications this should be set to disable(1). When the application is using rear cards or interface modules that do not have loop back ability from the DTE, such as the IM2RC/IA Ethernet rear card, this variable must be set to disable(1). In most situations, if a DTE test mode is required, it should be enable only during the time that the test is needed.
HW Test Mode (testModeIndiDSL/remotetestModeIndiDSL) These read-only variables notify you that the specified unit has been placed into a test mode through the hard- ware. This could have been done either through the front panel switches or from the DTE (if the TM from DTE is enabled). When a test mode is displayed, the field will be highlighted in blue to give you quick notification.
SW Test Mode (testModeSetiDSL/remotetestModeSetiDSL) These variables notify you that the specified unit has been placed into a test mode through the management station. The management can place a unit into a test mode within the Model 1092A Update Configuration page explained in more detail below.
Model 1092 Configuration Slot page MIB variables description 62

Model 1001MC Operations Guide 4 • Model 1092ARC management
Software Rev (softVersioniDSL/remotesoftversioniDSL) These read-only MIB variables display the current version of code that is running in the NetLink-iDSL modems. Check the Download page to see if the Model 1001MC has a newer version of code available for downloading. Through the download web page, you can update the software that is running in the NetLink- iDSL rack card. You can also update the software in the NetLink stand alone unit through the front panel con- trol port on the unit.
The Model 1092 Configuration—Next Configuration page enables you to update the configuration of the 1092ARC NetLink-iDSL modems that are installed in the system. After making changes to the configuration on this page, select Back to return to the Model 1092 Configuration Slot page, then select onLine as the Input Mode, and finally, select Submit Query to send the new information to the Model 1001MC over the network.
The following sections describes the MIB variables that are available on the Model 1092 Configuration—Next Configuration page.
Card Address (nmsSlotID) Displays the address of the selected NetLink-iDSL modem.
Line Status (lineStatusiDSL) This variable displays the status of the line. There are three possible values that can be displayed:
Processor Mode (processorModeiDSL) This variable displays the status of the processor running on the NetLink-iDSL. There are four values that are significant to you:
Model 1092 Configuration—Next Configuration page MIB variables description 63

Model 1001MC Operations Guide 4 • Model 1092ARC management
At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the NetLink-iDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set- ting of the card.
Local Software Rev (softVersioniDSL) These read-only MIB variable displays the current version of code that is running in the NetLink-iDSL rack card modem. You should check the download web page to see if the Model 1001MC has a newer version of code available for downloading. Through the download web page, you can update the software that is running in the NetLink-iDSL rack card.
Remote Software Rev (remotesoftversioniDSL) These read-only MIB variable displays the current version of code that is running in the NetLink-iDSL Cus- tomer Premise modem. You can update the software in the NetLink stand alone unit through the front panel control port on the unit. For more information regarding software downloads for standalone units, visit the Patton Electronics web site at www.patton.com.
Next Configuration table This table shows the configurable MIB variables for the set of units. There are column for the local and remote units. In some cases a single variable applies to both the local and remote unit. In this case, a single configura- tion field is made available in the Local column and the Remote column is made a read-only field. After changes are made, select the Submit Query button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model 1092 Configuration page.
The following sections explain the MIB variables that are shown in the Next Configuration table.
DTE rate (dteRateiDSL) This variable displays the DTE rate for the link. Because the NetLink-iDSL modems are symmetrical (same rate in both direction), there is only MIB variable that defines the DTE rate. The Customer Premise box will automatically update its' configuration to the DTE rate that is set here.
Clock Mode (Local-Remote) This variable defines the clock mode for the NetLink modems. The display shows the Local clock mode (rack card) and then the remote clock mode as a single variable in the Local column. The Remote column displays a read only field showing the remote units clocking mode. This was done to avoid an illegal configuration of the NetLink-iDSL modems. For instance, both units CAN NOT be set to internal clock. The options list all pos- sible clocking combinations.
TM From DTE (dteTMiDSL/remotedteTMiDSL) These MIB variables define whether you would like the modems to accept test mode requests from the DTE that is connected. In normal applications this should be set to disable(1). When the application is using rear cards or interface modules that do not have loop back ability from the DTE, such as the IM2RC/IA Ethernet rear card, this variable must be set to disable(1). In most situations, if a DTE test mode is required, it should be enable only during the time that the test is needed.
Test Mode (testModeSetiDSL/remotetestModeSetiDSL) These variables allow you to place the NetLink-iDSL rack card into test modes. For more information on the test modes, please see the NetLink-iDSL Test Modes section below.
Model 1092 Configuration—Next Configuration page MIB variables description 64

Model 1001MC Operations Guide 4 • Model 1092ARC management
Submit Query button After making configuration changes, select the Back link, then select onLine, and finally, select Submit Query. This will submit all the configuration information to the Model 1001MC. After this, the information is stored in volatile RAM until you place the Input Mode to onLine(0). This will tell the 1001MC to copy all of the configuration information into the NetLink-iDSL configuration space.
Clear Changes Once configuration changes have been made and you have selected the Submit Query button, if you decide not to implement these changes, select the Clear Changes button. This will set the configuration back to the settings that were there when this page was entered.
Set Default Configuration Selecting this button will place the default configuration into the Next Configuration table.
This section describes the MIB variables that are available on the Slot Configuration page. From the Modem Information page, the address column creates a list of hyperlinks to the Slot Configuration page associated with the specified address. The Slot Configuration page can be used to set slot-specific information related to the sys- tem and how the system treats the slot in the case of errors and warning.
Card Address (nmsSlotID) Displays the address of the card.
Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.
View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).
Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within this page.
Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, the User ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within this page.
Slot Configuration page MIB variables description 65
Card Identification Information

Model 1001MC Operations Guide 4 • Model 1092ARC management
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warning) associated with the specified slot.
Hardware Reset (resetStatus) Selecting this push button will force the associated modem to perform a hardware reset.
Card Lost Indication (cardLostIndication) This variable allows you to choose what type of indication will be made if a modem is removed from the man- agement system. Three choices are available:
Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. Three choices are available:
Slot Configuration page MIB variables description 66
Alarm Information



Model 1001MC Operations Guide 5 • Model 1094ARC management
This chapter describes managing a Model 1094ARC NetLink HDSL modem using the Model 1001MC NetLink-NMS internal HTTP/HTML web engine and a standard web browser. This chapter is meant to be used in addition to the manual that came with your unit.
NetLink-NMS description Specifically designed for use in the Patton NetLink system, when the NetLink HDSL is coupled with the Model 1001MC NetLink-NMS and the Patton Model 1001 rack system, the modem is fully SNMP manageable. SNMP management can be performed on both the local and remote units using a standard SNMP network man- agement station (NMS) or by using a standard web browser and the Model 1001MC's built-in web server. You can view and change configuration variables, view statistical variables, and view error and warning indications.
This section describes the configuration and management of your NetLink HDSL modems using a Model 1001MC NetLink-NMS with built in HTTP/HTML web server. If you plan to manage your units using a standard network management station you can download the Patton Enterprise MIBs either through the SNMP web page on the Model 1001MC or obtain them from the Patton web site at www.patton.com.
The following pages are used to configure and manage the Model 1094ARC:
Introduction 69

Model 1001MC Operations Guide 5 • Model 1094ARC management
Displaying the Modem Information page The Modem Information page (see figure 28) displays the cards installed in the system and a quick view of any errors or warnings associated with your modems.

Figure 28. Modem Information page for the Model 1094ARC
Starting from the HOME page, to access the Modem Information page for the 1094ARC, click on the following links: Configure Cards > View Rack 1. Figure 29 on page 71 shows the web page navigation required to get to this area of the system. For more information about items on the Modem Information page, see “Displaying the Slot Configuration page” on page 76.
Configuration and management 70

Model 1001MC Operations Guide 5 • Model 1094ARC management

Figure 29. Web page navigation to Modem Information page
Configuration and management 71

Model 1001MC Operations Guide 5 • Model 1094ARC management
Displaying the Model 1094 Configuration Slot page The Model 1094 Configuration Slot page (see figure 30) enables you to make configuration changes to the Model 1094A and the remote CPE box. When the page displays, the unit is set to the onLine state and the cur- rent configuration is displayed.

Figure 30. Model 1094 Configuration Slot page
Starting from the HOME page, to access the Model 1094 Configuration Slot page for the 1094ARC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 1094ARC you wish to manage (in the example shown in figure 30, the 1094ARC was installed in slot 11). Figure 31 on page 73 shows the web page navigation required to get to this area of the system.
Configuration and management 72

Model 1001MC Operations Guide 5 • Model 1094ARC management

Figure 31. Web page navigation to Model 1094 Configuration Slot page
Making configuration changes to your 1094ARC NetLink modem Do use the following to make configuration changes to your NetLink modem.
For more information about items on the Model 1094 Configuration Slot page, see “Model 1094 Configura- tion Slot page MIB variables description” on page 81.
Configuration and management 73

Model 1001MC Operations Guide 5 • Model 1094ARC management
Displaying the Model 1094 Configuration—Next Configuration page The Model 1094 Configuration—Next Configuration page (see figure 32) enables you to make configuration changes to the Model 1094A and the remote CPE box. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Figure 32. Model 1094 Configuration—Next Configuration page
Starting from the HOME page, to access the Model 1094 Configuration—Next Configuration page for the 1094ARC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 1094ARC you wish to manage > Modify Configuration (you first have to change input mode from onLine to superVisory- Mode. Figure 33 on page 75 shows the web page navigation required to get to this area of the system.
For more information about items on the Model 1094 Configuration—Next Configuration page, see “Model 1094 Configuration—Next Configuration page MIB variables description” on page 84.
Configuration and management 74

Model 1001MC Operations Guide 5 • Model 1094ARC management

Figure 33. Web page navigation to Model 1094 Configuration—Next Configuration page
Configuration and management 75

Model 1001MC Operations Guide 5 • Model 1094ARC management
Displaying the Slot Configuration page The Slot Configuration page (see figure 34) is used to set slot-specific information related to the system and how the system treats that slot in the case of errors or warnings.

Figure 34. Slot Configuration page
Starting from the HOME page, to access the Slot Configuration page for the 1094ARC, click on the following links: Configure Cards > View Rack 1 > Card_Address for the 1094ARC you wish to manage (in the example shown in figure 34, the 1094ARC was installed in slot 1). Figure 35 on page 77 shows the web page navigation required to get to this area of the system.
Configuration and management 76

Model 1001MC Operations Guide 5 • Model 1094ARC management

Figure 35. Web page navigation to Slot Configuration page
For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description” on page 86.
Displaying the Download page The Download page (see figure 36) is where you can download the latest version of 1001MC and 1094ARC software.

Figure 36. Download page
Configuration and management 77

Model 1001MC Operations Guide 5 • Model 1094ARC management
Starting from the HOME page, to access the Download page for the 1094ARC, click on the Download link. Figure 37 shows the web page navigation required to get to this area of the system.

Figure 37. Web page navigation to Download page
For more information about items on the Slot Configuration page, see “Using the Download page to upgrade 1094ARC software” on page 87.
This section describes the MIB variables that are available on the Modem Information page.
Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.
Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.
Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.
Rack Protection Mode If you want to protect all Model 1095RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the pop-up menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.
Modem Information page MIB variables description 78

Model 1001MC Operations Guide 5 • Model 1094ARC management
Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.
Power Supply 1 Status Displays the current status of power supply 1 as one of the following:
Power Supply 2 Status Displays the current status of power supply 2 as one of the following:
Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.
Card Address (nmsSlotID) This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the Model 1095 Configuration Slot page. This page can be used to set slot-specific information about the card.
Line Status The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:
Modem Information page MIB variables description 79

Model 1001MC Operations Guide 5 • Model 1094ARC management
Warnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more infor- mation on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warning for the slot can be erased in the Slot Configuration page.
Errors (errorCount) This field displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page.
Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.
Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration page for the NetLink modem and its remote unit. The model code information is passed to the Model 1001MC after the card is placed online. The Model 1001MC is auto- sensing, meaning that when a card is found or lost, the information will automatically be updated in the sys- tem. You are not required to setup the Model Code information for each slot. When a card is removed from the system, the Model Code will be erased and an error or warning will be displayed for the slot (this depends on the settings in the Slot Configuration page)
Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, you ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.
Remote Model Code (remoteModelCode) This column displays the model code of the Customer Premise NetLink modem at the far end of the link. This information is communicated from the CP box over the link to the CO Rack Card unit. The NetLink mDSL
Modem Information page MIB variables description 80

Model 1001MC Operations Guide 5 • Model 1094ARC management
rack card will then update the Model 1001MC. For this reason this information will not be available until after the link is made between the two modems.
Protected You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed within the Configure Cards page or from the Slot Configuration page. After clicking the Sub- mit Query button to input the string to the management system, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards web page or from the Slot Configuration page.
Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
This section describes the MIB variables that are available on the Model 1094 Configuration Slot page.
Model 1094A Model 1094 Configuration Slot (nmsSlotID) Displays the address of the NetLink HDSL modem. The address is defined by the DIP-switch setting of S1 on the rack card. The remote standalone unit has no address specified, but uses that address of the rack card that it is connected to.
Model 1094 Configuration Slot page MIB variables description 81

Model 1001MC Operations Guide 5 • Model 1094ARC management
Line Status (lineStatus1094) Displays the status of the line. There are three possible values that can be displayed:
When the line status is dataMode(2), the units are linked-up and ready to send data.
Processor Mode (processorMode1094) Displays the status of the processor running on the NetLink-HDSL. There are four values that are significant to you:
At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the NetLink-HDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set- ting of the card.
Input Mode (mode1094) The following settings are available:
To make configuration changes to the NetLink-HDSL modems, you must first set this bit to superVisoryMode1). When the Input Mode is set to superVisoryMode1), the Modify Configuration hyperlink will appear on the web page next to the Refresh Current Page hyperlink. Select the Modify Configuration hyperlink. The Model 1094A Configuration—Next Configuration page will appear (see section “Model 1094 Configuration—Next Configuration page MIB variables description” on page 84 for more information). After making configuration changes to the NetLink-HDSL modems in the Model 1094A Update Configuration page, return to this page and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has completed and will cause it to copy the new configuration into the NetLink-HDSL configuration space. If this is not done, the NetLink-HDSL will not recognize the configura- tion changes that were made.
Model 1094 Configuration Slot page Configuration Status table description The Configuration Status table shows the configuration for the set of units. There are columns for the local and remote units. If a field is highlighted in yellow, it signifies one of two possible conditions:
Model 1094 Configuration Slot page MIB variables description 82

Model 1001MC Operations Guide 5 • Model 1094ARC management
the NetLink-HDSL modem will update the configuration in the Model 1001MC with its last set of stored parameters. As these fields are updated in the Model 1001MC, the yellow highlighting will disappear, signi- fying that the information has been updated. After the local and remote units are linked, the units will begin updating the remote information in the table, and Line Status set to datamode(2).
The following sections define the MIB variables that are shown in the Configuration Status table.
Model Code (localModelCode/remoteModelCode) These variables display the local and remote models codes for the units that were found in the specified address.
DTE rate (dteRate1094) This variable displays the DTE rate for the link. Because the NetLink-HDSL modems are symmetrical (same rate in both direction), there is only one MIB variable that defines the DTE rate.
Clock Mode (Local-Remote) This variable defines the clock mode for the NetLink modems. The display shows the Local clock mode (rack card) and then the remote clock mode.
TM From DTE (dteTM1094/remotedteTM1094) These MIB variables define whether you would like the modems to accept test mode requests from the DTE that is connected. In normal applications this should be set to disable(1). When the application is using rear cards or interface modules that do not have loop back ability from the DTE, such as the IM2RC/IA Ethernet rear card, this variable must be set to disable(1). In most situations, if a DTE test mode is required, it should be enable only during the time that the test is needed.
HW Test Mode (testModeInd1094/remotetestModeInd1094) These read-only variables notify you that the specified unit has been placed into a test mode through the hard- ware. This could have been done either through the front panel switches or from the DTE (if the TM from DTE is enabled). When a test mode is displayed, the field will be highlighted in blue to give you quick notification.
SW Test Mode (testModeSet1094/remotetestModeSet1094) These variables notify you that the specified unit has been placed into a test mode through the management station. The management can place a unit into a test mode within the Model 1094A Update Configuration page explained in more detail below.
Software Rev (softVersion1094/remotesoftversion1094) These read-only MIB variables display the current version of code that is running in the NetLink-HDSL modems. Check the Download page to see if the Model 1001MC has a newer version of code available for downloading. Through the download web page, you can update the software that is running in the NetLink- HDSL rack card. You can also update the software in the NetLink stand alone unit through the front panel control port on the unit.
Model 1094 Configuration Slot page MIB variables description 83

Model 1001MC Operations Guide 5 • Model 1094ARC management
The Model 1094 Configuration—Next Configuration page enables you to update the configuration of the 1094ARC NetLink-HDSL modems that are installed in the system. After making changes to the configuration on this page, select Back to return to the Model 1094 Configuration Slot page, then select onLine as the Input Mode, and finally, select Submit Query to send the new information to the Model 1001MC over the network.
The following sections describes the MIB variables that are available on the Model 1094 Configuration—Next Configuration page.
Card Address (nmsSlotID) Displays the address of the selected NetLink-HDSL modem.
Line Status (lineStatus1094) This variable displays the status of the line. There are three possible values that can be displayed:
Processor Mode (processorMode1094) This variable displays the status of the processor running on the NetLink-HDSL. There are four values that are significant to you:
At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the NetLink-HDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set- ting of the card.
Local Software Rev (softVersion1094) These read-only MIB variable displays the current version of code that is running in the NetLink-HDSL rack card modem. You should check the download web page to see if the Model 1001MC has a newer version of code available for downloading. Through the download web page, you can update the software that is running in the NetLink-HDSL rack card.
Model 1094 Configuration—Next Configuration page MIB variables description 84

Model 1001MC Operations Guide 5 • Model 1094ARC management
Remote Software Rev (remotesoftversion1094) These read-only MIB variable displays the current version of code that is running in the NetLink-HDSL Cus- tomer Premise modem. You can update the software in the NetLink stand alone unit through the front panel control port on the unit. For more information regarding software downloads for standalone units, visit the Patton Electronics web site at www.patton.com.
Next Configuration table This table shows the configurable MIB variables for the set of units. There are column for the local and remote units. In some cases a single variable applies to both the local and remote unit. In this case, a single configura- tion field is made available in the Local column and the Remote column is made a read-only field. After changes are made, select the Submit Query button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model 1094 Configuration page.
The following sections explain the MIB variables that are shown in the Next Configuration table.
DTE rate (dteRate1094) This variable displays the DTE rate for the link. Because the NetLink-HDSL modems are symmetrical (same rate in both direction), there is only MIB variable that defines the DTE rate. The Customer Premise box will automatically update its' configuration to the DTE rate that is set here.
Clock Mode (Local-Remote) This variable defines the clock mode for the NetLink modems. The display shows the Local clock mode (rack card) and then the remote clock mode as a single variable in the Local column. The Remote column displays a read only field showing the remote units clocking mode. This was done to avoid an illegal configuration of the NetLink-HDSL modems. For instance, both units CAN NOT be set to internal clock. The options list all pos- sible clocking combinations.
Tx Data Sample Point (txdEdge1095/remotetxdEdge1095) This variable defines the sampling point that is used by the NetLink-mDSL modems to read data from the DTE. In most situations it should always be set to normal(0). In high speed applications, there are situations that would require an inverted(1) sampling point.
TM From DTE (dteTM1094/remotedteTM1094) These MIB variables define whether you would like the modems to accept test mode requests from the DTE that is connected. In normal applications this should be set to disable(1). When the application is using rear cards or interface modules that do not have loop back ability from the DTE, such as the IM2RC/IA Ethernet rear card, this variable must be set to disable(1). In most situations, if a DTE test mode is required, it should be enable only during the time that the test is needed.
Test Mode (testModeSet1094/remotetestModeSet1094) These variables allow you to place the NetLink-HDSL rack card into test modes. For more information on the test modes, please see the NetLink-HDSL Test Modes section below.
Submit Query button After making configuration changes, select the Back link, then select onLine, and finally, select Submit Query. This will submit all the configuration information to the Model 1001MC. After this, the information is stored
Model 1094 Configuration—Next Configuration page MIB variables description 85

Model 1001MC Operations Guide 5 • Model 1094ARC management
in volatile RAM until you place the Input Mode to onLine(0). This will tell the 1001MC to copy all of the configuration information into the NetLink-HDSL configuration space.
Clear Changes Once configuration changes have been made and you have selected the Submit Query button, if you decide not to implement these changes, select the Clear Changes button. This will set the configuration back to the settings that were there when this page was entered.
Set Default Configuration Selecting this button will place the default configuration into the Next Configuration table.
This section describes the MIB variables that are available on the Slot Configuration page. From the Modem Information page, the address column creates a list of hyperlinks to the Slot Configuration page associated with the specified address. The Slot Configuration page can be used to set slot-specific information related to the sys- tem and how the system treats the slot in the case of errors and warning.
Card Address (nmsSlotID) Displays the address of the card.
Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.
View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).
Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within this page.
Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, the User ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within this page.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Slot Configuration page MIB variables description 86
Card Identification Information

Model 1001MC Operations Guide 5 • Model 1094ARC management
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warning) associated with the specified slot.
Hardware Reset (resetStatus) Selecting this push button will force the associated modem to perform a hardware reset.
Card Lost Indication (cardLostIndication) This variable allows you to choose what type of indication will be made if a modem is removed from the man- agement system. Three choices are available:
Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. Three choices are available:
Do the following to download new software into your NetLink modem:
Using the Download page to upgrade 1094ARC software 87
Alarm Information

Model 1001MC Operations Guide 5 • Model 1094ARC management

Figure 38. Download 1094ARC software button

Figure 39. View Status link location
Congratulation! The software has been successfully upgraded.
Using the Download page to upgrade 1094ARC software 88




This chapter describes managing a Model 1095RC NetLink mDSL modem using the Model 1001MC NetLink-NMS internal HTTP/HTML web engine and a standard web browser. This chapter is meant to be used in addition to the manual that came with your unit.
NetLink-NMS description Specifically designed for use in the Patton NetLink system, when the NetLink mDSL is coupled with the Model 1001MC NetLink-NMS and the Patton Model 1001 rack system, the modem is fully SNMP manageable. SNMP management can be performed on both the local and remote units using a standard SNMP network man- agement station (NMS) or by using a standard web browser and the Model 1001MC's built-in web server. You can view and change configuration variables, view statistical variables, and view error and warning indications.
This section describes the configuration and management of your NetLink mDSL modems using a Model 1001MC NetLink-NMS with built in HTTP/HTML web server. If you plan to manage your units using a standard network management station you can download the Patton Enterprise MIBs either through the SNMP web page on the Model 1001MC or obtain them from the Patton web site at www.patton.com.
The following pages are used to configure and manage the Model 1095RC:
Introduction 92

Displaying the Global Configuration Menu page The Global Configuration Menu page (see figure 40) is where you can create templates that can globally config- ure the Model 1095RC. With this capability, you can globally configure some or all Model 1095RC modems in multiple racks, or just one rack.

Figure 40. Global Configuration Menu page for the Model 1095RC
Starting from the HOME page, to access the Modem Information page for the 1095RC, click on the System Con- fig link. Figure 41 shows the web page navigation required to get to this area of the system. For more informa- tion about items on the Global Configuration Menu page, see “Creating and modifying global configuration templates” on page 113.

Figure 41. Web page navigation to Global Configuration Menu page
Configuration and management 93

Displaying the Modem Information page The Modem Information page (see figure 42) displays the cards installed in the system and a quick view of any errors or warnings associated with your modems.

Figure 42. Modem Information page for the Model 1095RC
Starting from the HOME page, to access the Modem Information page for the 1095RC, click on the following links: Configure Cards > View Rack 1. Figure 43 shows the web page navigation required to get to this area of the system. For more information about items on the Modem Information page, see “Displaying the Slot Con- figuration page” on page 99.

Figure 43. Web page navigation to Modem Information page
Configuration and management 94

Displaying the Model 1095 Configuration Slot page The Model 1095 Configuration Slot page (see figure 44) enables you to make configuration changes to the Model 1095RC and the remote CPE box. When the page displays, the unit is set to the onLine state and the cur- rent configuration is displayed.

Figure 44. Model 1095 Configuration Slot page
Starting from the HOME page, to access the Model 1095 Configuration Slot page for the 1095RC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 1095RC you wish to manage (in the example shown in figure 44, the 1095RC was installed in slot 11). Figure 45 on page 96 shows the web page navigation required to get to this area of the system.
Configuration and management 95


Figure 45. Web page navigation to Model 1095 Configuration Slot page
Making configuration changes to your 1095RC NetLink modem Do use the following to make configuration changes to your NetLink modem.
For more information about items on the Model 1095 Configuration Slot page, see “After submitting the remote circuit ID information, you must click on the Record Current Configuration button located on the HOME page to store the configuration changes into memory (see “HOME” on page 228 for more informa- tion).” on page 104.
Configuration and management 96

Displaying the Model 1095 Configuration—Next Configuration page The Model 1095 Configuration—Next Configuration page (see figure 46) enables you to make configuration changes to the Model 1095RC and the remote CPE box. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Figure 46. Model 1095 Configuration—Next Configuration page
Starting from the HOME page, to access the Model 1095 Configuration—Next Configuration page for the 1095RC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 1095RC you wish to manage > Modify Configuration (you first have to change input mode from onLine to superVisoryMode. Figure 47 on page 98 shows the web page navigation required to get to this area of the system.
For more information about items on the Model 1095 Configuration—Next Configuration page, see “Model 1095 Configuration—Next Configuration page MIB variables description” on page 107.
Configuration and management 97


Figure 47. Web page navigation to Model 1095 Configuration—Next Configuration page
Configuration and management 98

Displaying the Slot Configuration page The Slot Configuration page (see figure 48) is used to set slot-specific information related to the system and how the system treats that slot in the case of errors or warnings.

Figure 48. Slot Configuration page
Starting from the HOME page, to access the Slot Configuration page for the 1095RC, click on the following links: Configure Cards > View Rack 1 > Card_Address for the 1095RC you wish to manage (in the example shown in figure 48, the 1095RC was installed in slot 1). Figure 49 on page 100 shows the web page navigation required to get to this area of the system.
Configuration and management 99


Figure 49. Web page navigation to Slot Configuration page
For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description” on page 110.
Displaying the Download page The Download page (see figure 50) is where you can download the latest version of 1001MC and 1095RC software.
Figure 50. Download page
Configuration and management 100

Starting from the HOME page, to access the Download page for the 1095RC, click on the Download link. Figure 51 shows the web page navigation required to get to this area of the system.

Figure 51. Web page navigation to Download page
For more information about items on the Download page, see “Using the Download page to upgrade 1095RC software” on page 111.
This section describes the MIB variables that are available on the Modem Information page.
Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.
Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.
Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.
Rack Protection Mode If you want to protect all Model 1095RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the pop-up menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.
Modem Information page MIB variables description 101

Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.
Power Supply 1 Status Displays the current status of power supply 1 as one of the following:
Power Supply 2 Status Displays the current status of power supply 2 as one of the following:
Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.
Card Address (nmsSlotID) This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the Model 1095 Configuration Slot page. This page can be used to set slot-specific information about the card.
Line Status The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:
Modem Information page MIB variables description 102

Warnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more infor- mation on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warning for the slot can be erased in the Slot Configuration page.
Errors (errorCount) This field displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page.
Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.
Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration page for the NetLink modem and its remote unit. The model code information is passed to the Model 1001MC after the card is placed online. The Model 1001MC is auto- sensing, meaning that when a card is found or lost, the information will automatically be updated in the sys- tem. You are not required to setup the Model Code information for each slot. When a card is removed from the system, the Model Code will be erased and an error or warning will be displayed for the slot (this depends on the settings in the Slot Configuration page)
Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, you ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.
Remote Model Code (remoteModelCode) This column displays the model code of the Customer Premise NetLink modem at the far end of the link. This information is communicated from the CP box over the link to the CO Rack Card unit. The NetLink mDSL
Modem Information page MIB variables description 103

rack card will then update the Model 1001MC. For this reason this information will not be available until after the link is made between the two modems.
Protected You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed within the Configure Cards page or from the Slot Configuration page. After clicking the Sub- mit Query button to input the string to the management system, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards web page or from the Slot Configuration page.
Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
This section describes the MIB variables that are available on the Model 1095 Configuration Slot page.
Model 1095RC Model 1095 Configuration Slot (nmsSlotID) Displays the address of the NetLink mDSL modem. The address is defined by the DIP-switch setting of S1 on the rack card. The remote standalone unit has no address specified, but uses that address of the rack card that it is connected to.
Model 1095 Configuration Slot page MIB variables description 104

Line Status (lineStatus1095) Displays the status of the line. There are three possible values that can be displayed:
When the line status is dataMode(2), the units are linked-up and ready to send data.
Processor Mode (processorMode1095) Displays the status of the processor running on the NetLink-mDSL. There are four values that are significant to you:
At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the NetLink-mDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set- ting of the card.
Previous Card button Click the Previous Card button to display the rack card configuration in the next occupied slot (in descend- ing order).
Refresh Current Page button Clicking the Refresh Current Page button displays updated configuration information.
Next Card button Click the Next Card button to display the rack card configuration in the next occupied slot (in descending order).
View Rack X hyperlink Click on this link to display the Modem Information Rack X page. The Modem Information Rack page displays an overview of the NetLink rack that is being managed. For more information, refer to section “Modem Informa- tion Rack X” on page 239.
Model 1095 Configuration Slot page MIB variables description 105

Input Mode (mode1095) The following settings are available:
To make configuration changes to the NetLink-mDSL modems, you must first set this bit to superVisoryMode1). When the Input Mode is set to superVisoryMode1), the Modify Configuration hyperlink will appear on the web page next to the Refresh Current Page hyperlink. Select the Modify Configuration hyperlink. The Model 1095RC Configuration—Next Configuration page will appear (see section “Model 1095 Configuration—Next Configuration page MIB variables description” on page 107 for more information). After making configuration changes to the NetLink-mDSL modems in the Model 1095RC Update Configura- tion page, return to this page and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has completed and will cause it to copy the new configuration into the NetLink-mDSL configuration space. If this is not done, the NetLink-mDSL will not recognize the configura- tion changes that were made.
Model 1095 Configuration Slot page Configuration Status table description The Configuration Status table shows the configuration for the set of units. There are columns for the local and remote units. If a field is highlighted in yellow, it signifies one of two possible conditions:
The following sections define the MIB variables that are shown in the Configuration Status table.
Model Code (localModelCode/remoteModelCode) These variables display the local and remote models codes for the units that were found in the specified address.
DTE rate (dteRate1095) This variable displays the DTE rate for the link. Because the NetLink-mDSL modems are symmetrical (same rate in both direction), there is only one MIB variable that defines the DTE rate.
Clock Mode (Local-Remote) This variable defines the clock mode for the NetLink modems. The display shows the Local clock mode (rack card) and then the remote clock mode.
Tx Data Sample Point (txdEdge1095/remotetxdEdge1095) This variable defines the sampling point that is used by the NetLink-mDSL modems to read data from the DTE. In most situations it should always be set to normal(0). In high speed applications, there are situations that would require an inverted(1) sampling point.
Model 1095 Configuration Slot page MIB variables description 106

TM From DTE (dteTM1095/remotedteTM1095) These MIB variables define whether you would like the modems to accept test mode requests from the DTE that is connected. In normal applications this should be set to disable(1). When the application is using rear cards or interface modules that do not have loop back ability from the DTE, such as the IM2RC/IA Ethernet rear card, this variable must be set to disable(1). In most situations, if a DTE test mode is required, it should be enable only during the time that the test is needed.
Framing Mode This bit defines the mode of operation of the interface. For standard serial interfaces Framing Mode should be set to normal(3). Please refer to the user manual that came with the Model 1095RC for more information.
Note Framing mode was introduced into the Model 1095RC modems at software revision 2.2.0. If you have a modem with a software revision earlier than this it will ignore the framing mode bit. On the 1001MC web page the bit will always be highlighted in yellow showing that the bit is not being updated. Contact Patton Electronics for software upgrades for your units if you require this feature.
HW Test Mode (testModeInd1095/remotetestModeInd1095) These read-only variables notify you that the specified unit has been placed into a test mode through the hard- ware. This could have been done either through the front panel switches or from the DTE (if the TM from DTE is enabled). When a test mode is displayed, the field will be highlighted in blue to give you quick notification.
SW Test Mode (testModeSet1095/remotetestModeSet1095) These variables notify you that the specified unit has been placed into a test mode through the management station. The management can place a unit into a test mode within the Model 1095RC Update Configuration page explained in more detail below.
Software Rev (softVersion1095/remotesoftversion1095) These read-only MIB variables display the current version of code that is running in the NetLink-mDSL modems. Check the Download page to see if the Model 1001MC has a newer version of code available for downloading. Through the download web page, you can update the software that is running in the NetLink- mDSL rack card. You can also update the software in the NetLink stand alone unit through the front panel control port on the unit.
The Model 1095 Configuration—Next Configuration page enables you to update the configuration of the 1095RC NetLink-mDSL modems that are installed in the system. After making changes to the configuration on this page, select Back to return to the Model 1095 Configuration Slot page, then select onLine as the Input Mode, and finally, select Submit Query to send the new information to the Model 1001MC over the network.
Model 1095 Configuration—Next Configuration page MIB variables description 107

The following sections describes the MIB variables that are available on the Model 1095 Configuration—Next Configuration page.
Card Address (nmsSlotID) Displays the address of the selected NetLink-mDSL modem.
Line Status (lineStatus1095) This variable displays the status of the line. There are three possible values that can be displayed:
Processor Mode (processorMode1095) This variable displays the status of the processor running on the NetLink-mDSL. There are four values that are significant to you:
At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As the NetLink-mDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set- ting of the card.
Local Software Rev (softVersion1095) These read-only MIB variable displays the current version of code that is running in the NetLink-mDSL rack card modem. You should check the download web page to see if the Model 1001MC has a newer version of code available for downloading. Through the download web page, you can update the software that is running in the NetLink-mDSL rack card.
Remote Software Rev (remotesoftversion1095) These read-only MIB variable displays the current version of code that is running in the NetLink-mDSL Cus- tomer Premise modem. You can update the software in the NetLink stand alone unit through the front panel control port on the unit. For more information regarding software downloads for standalone units, visit the Patton Electronics web site at www.patton.com.
Back… hyperlink After making modifications, click the Back hyperlink, thereby returning the unit to onLine mode to implement the changes.
Model 1095 Configuration—Next Configuration page MIB variables description 108

Next Configuration table This table shows the configurable MIB variables for the set of units. There are column for the local and remote units. In some cases a single variable applies to both the local and remote unit. In this case, a single configura- tion field is made available in the Local column and the Remote column is made a read-only field. After changes are made, select the Submit Query button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model 1095 Configuration page.
The following sections explain the MIB variables that are shown in the Next Configuration table.
DTE rate (dteRate1095) This variable displays the DTE rate for the link. Because the NetLink-mDSL modems are symmetrical (same rate in both direction), there is only MIB variable that defines the DTE rate. The Customer Premise box will automatically update its' configuration to the DTE rate that is set here.
Clock Mode (Local-Remote) This variable defines the clock mode for the NetLink modems. The display shows the Local clock mode (rack card) and then the remote clock mode as a single variable in the Local column. The Remote column displays a read only field showing the remote units clocking mode. This was done to avoid an illegal configuration of the NetLink-mDSL modems. For instance, both units CAN NOT be set to internal clock. The options list all pos- sible clocking combinations.
Tx Data Sample Point (txdEdge1095/remotetxdEdge1095) This variable defines the sampling point that is used by the NetLink-mDSL modems to read data from the DTE. In most situations it should always be set to normal(0). In high speed applications, there are situations that would require an inverted(1) sampling point.
TM From DTE (dteTM1095/remotedteTM1095) These MIB variables define whether you would like the modems to accept test mode requests from the DTE that is connected. In normal applications this should be set to disable(1). When the application is using rear cards or interface modules that do not have loop back ability from the DTE, such as the IM2RC/IA Ethernet rear card, this variable must be set to disable(1). In most situations, if a DTE test mode is required, it should be enable only during the time that the test is needed.
Framing Mode This bit defines the mode of operation of the interface. The following options are available:
For standard serial interfaces Framing Mode should be set to normal(3). Please refer to the user manual that came with the Model 1095RC for more information.
Note Framing mode was introduced into the Model 1095RC modems at software revision 2.2.0. If you have a modem with a software revision earlier than this it will ignore the framing mode bit. On the 1001MC web page the bit will always be highlighted in yellow showing that the bit is not being updated. Contact Patton Electronics for software upgrades for your units if you require this feature.
Model 1095 Configuration—Next Configuration page MIB variables description 109

Test Mode (testModeSet1095/remotetestModeSet1095) These variables allow you to place the NetLink-mDSL rack card into test modes. For more information on the test modes, please see the NetLink-mDSL Test Modes section below.
Submit Query button After making configuration changes, select the Back link, then select onLine, and finally, select Submit Query. This will submit all the configuration information to the Model 1001MC. After this, the information is stored in volatile RAM until you place the Input Mode to onLine(0). This will tell the 1001MC to copy all of the configuration information into the NetLink-mDSL configuration space.
Clear Changes Once configuration changes have been made and you have selected the Submit Query button, if you decide not to implement these changes, select the Clear Changes button. This will set the configuration back to the settings that were there when this page was entered.
Set Default Configuration Selecting this button will place the default configuration into the Next Configuration table.
This section describes the MIB variables that are available on the Slot Configuration page. From the Modem Information page, the address column creates a list of hyperlinks to the Slot Configuration page associated with the specified address. The Slot Configuration page can be used to set slot-specific information related to the sys- tem and how the system treats the slot in the case of errors and warning.
Card Address (nmsSlotID) Displays the address of the card.
Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.
View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).
Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within this page.
Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, the User ID will move to the new slot making it
Slot Configuration page MIB variables description 110
Card Identification Information

useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within this page.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warning) associated with the specified slot.
Hardware Reset (resetStatus) Selecting this push button will force the associated modem to perform a hardware reset.
Card Lost Indication (cardLostIndication) This variable allows you to choose what type of indication will be made if a modem is removed from the man- agement system. Three choices are available:
Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. Three choices are available:
Do the following to download new software into your NetLink modem:
Using the Download page to upgrade 1095RC software 111
Alarm Information


Figure 52. Download 1095RC software button
Figure 53. View Status link location
Congratulation! The software has been successfully upgraded.
Using the Download page to upgrade 1095RC software 112

Model 1095RC rack cards can be configured globally by templates you create. If you use this capability, you have the option to globally configure some or all Model 1095RC modems in multiple racks, or those in just one rack.
This section contains the following information to help you configure and use templates:
Protecting Model 1001 racks and Model 1095RC modems from global modification This section describes how to protect 1001 racks and 1095RC modem cards from being modified when a glo- bal modification is applied. This is useful if you are setting all but a few cards to the same configuration.
Select the appropriate option from following configuration choices:
Creating and modifying global configuration templates 113

Protecting a Model 1001 rack from global configuration Do the following to protect a Model 1001 rack:

Figure 54. System Level Information page
Creating and modifying global configuration templates 114


Figure 55. Web page navigation to System Level Information page
The rack is now protected.
Creating and modifying global configuration templates 115

Protecting a Model 1095RC rack card from global configuration Do the following to protect a single Model 1095RC rack card:

Figure 56. Modem Information Rack 1 page

Figure 57. Web page navigation to Modem Information Rack 1 page
Creating and modifying global configuration templates 116

The rack card is now protected.
Creating a template This section describes how to create a global configuration template. The Patton Model 1095 enables the Model 1001MC system administrator to configure the units for a wide variety of applications. Due to the many different applications that are supported, care must be taken when setting the configuration of your modems. There are several illegal combinations of variables that could cause problems with the modems if implemented incorrectly. Be sure to read the following information before creating a template:
After reviewing the rules and notes, go to section “Procedure for creating a template” on page 119 to learn how to create a template.
Configuration rules Keep in mind the following when creating a template:
Creating and modifying global configuration templates 117

There are special situations which would require the use of the external-external(4) clock mode setting. This setting should only be used when the application has an IM2RC/K and a 1095RC in the rack system and a IM1/K and a 1095 standalone at the remote site. If you are using any other interface cards do not use the exter- nal-external(4) configuration.
Notes on framing mode settings The Framing Mode Setting notifies the card of the type of interface it will be connected to. When you are using an IM2RC/K with a 1095RC rack card, the system administrator should set the Local Clock Mode to external (either external-receiveRecover(1) or external-external(4)) and the Local Framing Mode to slotted. When you are using an IM1/K and a 1095 standalone at the remote site, the system administrator should set the Clock Mode to external-external(4) and the Remote Framing Mode to slotted.
Illegal configuration messages If you are receiving an invalid configuration indication after creating a configuration, it is resulting from an illegal combination of variables. In most cases, the cause of the problem has to do with the Framing Mode vari- able. Patton DSL modems should only be set to the slotted mode when you are using an IM2RC/K with the 1095RC or an IM1/K with the 1095 standalone unit. Also, if you are using a IM2RC/K or IM1/K interface card, the 1095/1095RC must always be set to the external clock mode. Review the table below for a list of valid configurations that can be used with the 1095/1095RC.
Local Clock Mode Local Framing Mode Remote Clock Mode Remote Framing Mode
Internal Normal Receive Recover Normal External Normal Receive Recover Normal
Externala Slotted Receive Recover Normal
Externala Slotted Externala
Slotted Receive Recover Normal Internal Normal Receive Recover Normal External Normal
a. Denotes a unit that must have an IM2RC/K or IM1/K installed.
Creating and modifying global configuration templates 118

Procedure for creating a template

Figure 58. Global Configuration Menu page
Do the following to create a template:
The Model 1095 Global Configuration window displays (see figure 59).

Figure 59. Model 1095 Global Configuration page
Creating and modifying global configuration templates 119

– rate64k(3) – rate640k(12) – rate1280k(22) – rate1856k(32)
– rate128k(4) – rate704k(13) – rate1344k(23) – rate1920k(33)
– rate192k(5) – rate768k(14) – rate1408k(24) – rate1984k(34)
– rate256k(6) – rate832k(15) – rate1472k(25) – rate2048k(35)
– rate320k(7) – rate896k(16) – rate1536k(26) – rate2112k(36)
– rate384k(8) – rate960k(17) – rate1600k(28) – rate2176k(37)
– rate448k(9) – rate1024k(18) – rate1664k(29) – rate2240k(38)
– rate512k(10) – rate1088k(19) – rate1728k(30) – rate2304k(39)
– rate576k(11) – rate1216k(21) – rate1792k(31)
Creating and modifying global configuration templates 120

Refer to section “Applying a template” on page 125 to activate the template.
Modifying a template This section describes how to modify a global configuration template. The Patton Model 1095 enables the Model 1001MC system administrator to configure the units for a wide variety of applications. Due to the many different applications that are supported, care must be taken when setting the configuration of your modems. There are several illegal combinations of variables that could cause problems with the modems if implemented incorrectly. Be sure to read the following information before creating a template:
After reviewing the rules and notes, go to section “Procedure for modifying a template” on page 123 to learn how to modify a template.
Configuration rules Keep in mind the following when modifying a template:
Creating and modifying global configuration templates 121
– normal(3) · – slotted(0) · – normal(3)

the unit, so it is not necessary to have a G.703/G.704 link available. When using any other type of serial inter- face, make sure that an external clock is provided by the DTE equipment or the modems will not link.
There are special situations which would require the use of the external-external(4) clock mode setting. This setting should only be used when the application has an IM2RC/K and a 1095RC in the rack system and a IM1/K and a 1095 standalone at the remote site. If you are using any other interface cards do not use the exter- nal-external(4) configuration.
Notes on framing mode settings The Framing Mode Setting notifies the card of the type of interface it will be connected to. When you are using an IM2RC/K with a 1095RC rack card, the system administrator should set the Local Clock Mode to external (either external-receiveRecover(1) or external-external(4)) and the Local Framing Mode to slotted. When you are using an IM1/K and a 1095 standalone at the remote site, the system administrator should set the Clock Mode to external-external(4) and the Remote Framing Mode to slotted.
Illegal configuration messages If you are receiving an invalid configuration indication after creating a configuration, it is resulting from an illegal combination of variables. In most cases, the cause of the problem has to do with the Framing Mode vari- able. Patton DSL modems should only be set to the slotted mode when you are using an IM2RC/K with the 1095RC or an IM1/K with the 1095 standalone unit. Also, if you are using a IM2RC/K or IM1/K interface card, the 1095/1095RC must always be set to the external clock mode. Review the table below for a list of valid configurations that can be used with the 1095/1095RC.
Local Clock Mode Local Framing Mode Remote Clock Mode Remote Framing Mode
Internal Normal Receive Recover Normal External Normal Receive Recover Normal
Externala Slotted Receive Recover Normal
Externala Slotted Externala
Slotted Receive Recover Normal Internal Normal Receive Recover Normal External Normal
a. Denotes a unit that must have an IM2RC/K or IM1/K installed.
Creating and modifying global configuration templates 122

Procedure for modifying a template
Figure 60. Global Configuration Menu page
Do the following to modify a template:
The Model 1095 Global Configuration window displays (see figure 59).
Figure 61. Model 1095 Global Configuration page
Creating and modifying global configuration templates 123

– rate64k(3) – rate640k(12) – rate1280k(22) – rate1856k(32)
– rate128k(4) – rate704k(13) – rate1344k(23) – rate1920k(33)
– rate192k(5) – rate768k(14) – rate1408k(24) – rate1984k(34)
– rate256k(6) – rate832k(15) – rate1472k(25) – rate2048k(35)
– rate320k(7) – rate896k(16) – rate1536k(26) – rate2112k(36)
– rate384k(8) – rate960k(17) – rate1600k(28) – rate2176k(37)
– rate448k(9) – rate1024k(18) – rate1664k(29) – rate2240k(38)
– rate512k(10) – rate1088k(19) – rate1728k(30) – rate2304k(39)
– rate576k(11) – rate1216k(21) – rate1792k(31)
Creating and modifying global configuration templates 124

Refer to section “Applying a template” on page 125 to activate the template.
Figure 62. Global Configuration Menu page
Deleting a template Do the following to delete a template:
Applying a template This section describes how to apply a global configuration to all Model 1095RC rack cards other than those that meet one of the following exceptions:
Creating and modifying global configuration templates 125
– normal(3) · – slotted(0) · – normal(3)

Select the appropriate option from following configuration choices:
Configure all Model 1095RC rack cards in all Model 1001 racks Do the following to apply global configuration to all Model 1095RC rack cards in all Model 1001 racks:

Figure 63. System Level Information page
Creating and modifying global configuration templates 126


Figure 64. Web page navigation to System Level Information page
The template has been applied.
Creating and modifying global configuration templates 127

Configure all Model 1095RC rack cards in one Model 1001 rack Do the following to apply global configuration to all Model 1095RC rack cards installed in one Model 1001 rack:

Figure 65. System Level Information page
The template has been applied.
Creating and modifying global configuration templates 128




This chapter describes managing a Model 2701RC NetLink-G.703/G.704 network termination unit (NTU) using the Model 1001MC NetLink-NMS internal HTTP/HTML web engine and a standard web browser. This chapter is meant to be used in addition to the manual that came with your unit.
NetLink-NMS description Specifically designed for use in the Patton NetLink system, when the NetLink-G.703/G.704 NTU is coupled with the Model 1001MC NetLink-NMS and the Patton Model 1001 rack system, the modem is fully SNMP manageable. SNMP management can be performed on both the local and remote units using a standard SNMP network management station (NMS) or by using a standard web browser and the Model 1001MC's built-in web server. You can view and change configuration variables, view statistical variables, and view error and warning indications.
This section describes the configuration and management of your NetLink G.703/G.704 NTUs using a Model 1001MC NetLink-NMS with built in HTTP/HTML web server. If you plan to manage your units using a standard network management station you can download the Patton Enterprise MIBs either through the SNMP web page on the Model 1001MC or obtain them from the Patton web site at www.patton.com.
The following pages are used to configure and manage the Model 2701RC:
Introduction 132

Displaying the Modem Information page The Modem Information page (see figure 66) displays the cards installed in the system and a quick view of any errors or warnings associated with your modems.

Figure 66. Modem Information page for the Model 2701RC
Starting from the HOME page, to access the Modem Information Rack X page for the 2701RC, click on the fol- lowing links: Home (menu) > Configure Cards (menu) > View Rack [rack number]. Figure 67 on page 134 shows the web page navigation required to get to this area of the system. For more information about items on the Modem Information Rack X page, see “Displaying the Slot Configuration Page” on page 139.
Configuration and management 133


Figure 67. Web page navigation to Modem Information page
Configuration and management 134

Displaying the Model 2701RC Configuration Slot page The Model 2701RC Configuration Slot page (see figure 68) enables you to make configuration changes to the Model 2701RC and the remote NTU. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Figure 68. Model 2701RC Configuration Slot page
Starting from the HOME page, to access the Model 2701RC Configuration Slot page for the 2701RC, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > model2701RC-xxx(x) (in the Local Model Code column) for the 2701RC you wish to manage (in the example shown in figure 68, the 2701RC was installed in slot 4). Figure 69 on page 136 shows the web page navigation required to get to this area of the system.
Configuration and management 135


Figure 69. Web page navigation to Model 2701RC Configuration Slot page
Making configuration changes to your 2701RC NetLink NTU Do use the following to make configuration changes to your NetLink NTU.
For more information about items on the Model 2701 Configuration Slot page, see “Model 2701RC Config- uration Slot X page MIB variables description” on page 143.
Configuration and management 136

Displaying the Model 2701 Configuration page The Model 2701 Configuration page (see figure 70) enables you to make configuration changes to the Model 2701RC and the remote CPE box.

Figure 70. Model 2701 Configuration page
Starting from the HOME page, to access the Model 2701 Configuration page for the 2701RC, click on the fol- lowing links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > model2701RC-xxx(x) (in the Local Model Code column) for the 2701RC you wish to manage > Modify Configuration (you first have to change input mode from onLine to superVisoryMode. Figure 71 on page 138 shows the web page navigation required to get to this area of the system.
For more information about items on the Model 2701 Configuration page, see “Model 2701 Configuration page MIB variables description” on page 149.
Configuration and management 137


Figure 71. Web page navigation to Model 2701 Configuration page
Configuration and management 138

Displaying the Slot Configuration Page The Slot Configuration Page (see figure 72) is used to set slot-specific information related to the system and how the system treats that slot in the case of errors or warnings.

Figure 72. Slot Configuration Page
Starting from the HOME page, to access the Slot Configuration page for the 2701RC, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > X in the Card_Address column for the 2701RC you wish to manage (in the example shown in figure 72, the 2701RC was installed in slot 4). Figure 73 on page 140 shows the web page navigation required to get to this area of the system.
Configuration and management 139


Figure 73. Web page navigation to Slot Configuration Page
For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description” on page 153.
This section describes the MIB variables that are available on the Modem Information Rack X page. Starting from the HOME page, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number].
Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.
Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.
Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.
Rack Protection Mode (rackXProtected) If you want to protect all Model 2701RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the drop-down menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.
Modem Information Rack X page MIB variables description 140

Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.
Power Supply 1 Status (rackXPower1Down) Displays the current status of power supply 1 as one of the following:
Power Supply 2 Status (rackXPower2Down) Displays the current status of power supply 2 as one of the following:
Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.
Card Address (nmsSlotID) This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the Model 1095 Configuration Slot page. This page can be used to set slot-specific information about the card.
Line Status (lineStatus) The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:
Modem Information Rack X page MIB variables description 141

Warnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more infor- mation on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warning for the slot can be erased in the Slot Configuration page.
Errors (errorCount) This field displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page.
Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.
Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration page for the NetLink modem and its remote unit. The model code information is passed to the Model 1001MC after the card is placed online. The Model 1001MC is auto- sensing, meaning that when a card is found or lost, the information will automatically be updated in the sys- tem. You are not required to setup the Model Code information for each slot. When a card is removed from the system, the Model Code will be erased and an error or warning will be displayed for the slot (this depends on the settings in the Slot Configuration page)
Remote User Id (remoteUserID)
Remote Model Code (remoteModelCode)
Modem Information Rack X page MIB variables description 142

Protected (disableGlobalConfig) You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed within the Configure Cards page or from the Slot Configuration page. After clicking the Sub- mit Query button to input the string to the management system, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards web page or from the Slot Configuration page.
Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
This section describes the MIB variables that are available on the Model 2701RC Configuration Slot X page. (See figure 68 on page 135). Starting from the HOME page, click on the following links: Home (menu) > Config- ure Cards (menu) > View Rack [rack number] > model2701RC-xxx(x) (in the Local Model Code column).
Model 2701RC Configuration Slot (nmsSlotID) Displays the address of the NetLink E1-G.703/G.704 NTU. The address is defined by the DIP-switch setting of S3 and S4 on the rack card.
Model 2701RC Configuration Slot X page MIB variables description 143

Line Status (lineStatus) Displays the status of the line. There are three possible values that can be displayed:
Alarm counters For the four alarm counters, you may choose to do numerous actions upon detecting errors: nothing, incre- ment the counter upon each occurrences of the error, send an SNMP trap, or send a Syslog message. The choice is determined by configuring the Line Down Indicator on the Slot Configuration Page. The following table clarifies what the parameter will do.
Send a Syslog message Increment the Alarm Counter
on the web page Send an SNMP trap
None ✔ Warning ✔ ✔ Error ✔ ✔ ✔
LOS (losAlarm) Displays the number of times Loss of Sync on the E1 line is detected. It is incremented when synchronization to the E1 stream is lost. This number is accumulating in the 1001MC.
Model 2701RC Configuration Slot X page MIB variables description 144

AIS (aisAlarm) Displays the number of times an Alarm Indication Signal on the E1 line is detected. This should be set when an unframed all ones code is received at RPOSI and RNEGI. This number is accumulating in the 1001MC.
Flap Count (lineDownCnt) Displays the number of times the E1 line has been up and then becomes down. This should be set when the E1 line is up and becomes down. This number is accumulating in the 1001MC.
CRC4 Error (crc4Error) Displays the number of CRC4 errors received by the E1 interface. This is an error counter that records word errors in the CRC4. The counter is disabled during loss of sync. This number is accumulating in the 1001MC.
The Clear Counter button This button clears all alarm counters.
Model 2701RC Configuration Slot X page MIB variables description 145

CRC4 Error Alarm Threshold (crc4Threshold) The valid setting for the threshold is 0 to 255. By setting a threshold, the CRC4 Alarm counter will not issue the error/warning, Syslog, and SNMP Trap message unless the accumulating CRC4 Error Counter is greater than the threshold. The Record Current Configuration button will store the setting of the alarm threshold.
Input Mode (mode2701RC) The following settings are available:
To make configuration changes to the NetLink-E1 NTUs, you must first set this bit to superVisoryMode(1). When the Input Mode is set to superVisoryMode1), the Modify Configuration hyperlink will appear. Select the Modify Configuration hyperlink. The Model 2701 Configuration page will appear (see section “Model 2701 Configuration page MIB variables description” on page 149 for more information). After making config- uration changes to the NetLink-E1 NTUs in the Model 2701RC Configuration page, return to this page by clicking on the Back… hyperlink and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has completed and will cause it to copy the new configuration into the NetLink-E1 NTU configuration space. If this is not done, the NetLink-E1 NTU will not recognize the config- uration changes that were made.
Model 2701 Configuration Slot page Configuration Status table description The Configuration Status table shows the configuration for the set of units. There are columns for the local and remote units. If a field is highlighted in yellow, it signifies one of two possible conditions:
The following sections define the MIB variables that are shown in the Configuration Status table.
Configuration Status (configStatus2701RC) This is the title of the status table and displays the configuration status of the rack card. The following status can be displayed:
Local Model Code (localModelCode/remoteModelCode) These variables display the local and remote models codes for the units that were found in the specified address.
Model 2701RC Configuration Slot X page MIB variables description 146

Line Format (lineFormat) The following status variables can be displayed:
Clock Mode (clockMode2701RC) This variable defines the clock mode for the NetLink-E1 modems. The following status variables can be dis- played:
DTE Rate (dteRate2701RC) This variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of acti- vated channels.
Line Coding (lineCoding2701RC) The following status variables can be displayed:
CRC4 Framing (crc) This displays if CRC-4 framing is enabled or disabled.
CAS Multiframing (casMF) This displays if CAS multiframing is enabled or disabled.
Line Build Out (lineBuildOut) This displays the selected line build out: either 75 ohm or 120 ohm.
Tx Clock Timing (txClock) This displays whether the serial transmit data coming from the DTE is clocked in using the DCE provided transmit clock or DTE provided external clock.
SW/HW Test Mode (testModeSetInd) This displays any test mode invoked from the toggle switches, DTE test mode lines, or from the web manage- ment page. This option will be highlighted in blue if the unit is in test mode. In the status of the parameter, SW means initiated via the web management page or HW means initiated from the toggle switches or DTE test mode interface signals on the remote standalone unit.
Model 2701RC Configuration Slot X page MIB variables description 147

SW Test Mode (testModeSet2701RC) This displays any test mode invoked through the NMS. See next configuration for information about invoking test modes through the NMS. This option will be highlighted in blue if the unit is in test mode.
RDL Response (v54Loop) This displays if the unit will respond to a V.54 loop up command (enabled) or if the unit will ignore a V.54 loop up command (disabled).
FP Switches (frntSwitch) This displays if the front panel toggle switches used for loopbacks and pattern generators are enabled or disabled.
Pattern Select (patternSelect) This displays the pattern (511, 2047, QRSS) that is used when the pattern generator and detector are turned on.
Loop Time Out (loopTo) This displays the amount of time that the unit responding to a Remote Loop command will remain in test mode when the RL test mode is invoked. If the unit is not taken out of test mode by the menu within this time
Model 2701RC Configuration Slot X page MIB variables description 148

period, the unit will automatically time out and return to normal data mode. The timeout does not apply for loops selected via the front panel switches.
RDL type (rdlType) This displays the selected remote loopback type that will be used when initiating a remote loopback. The two loopback types are CSU and RDL.
Configuration Type (configType) This displays if the 2701RC is using the DIP switch control or software control for its configuration.
TM from DTE (testModeDTE) This displays if the 2701RC responds to the LL and RDL signals coming from the DTE.
Software Version (softVersion2701RC) This displays the software version of code in the 2701RC.
Reset button Software reset the E-carrier function card on its next poll from 1001MC.
The Model 2701 Configuration page enables you to update the configuration of the 2701RC NetLink-E1 NTU modems that are installed in the system. After making changes to the configuration on this page, select Back to return to the Model 2701 Configuration Slot page, then select onLine as the Input Mode, and finally, select Sub- mit Query to send the new information to the Model 1001MC over the network. Starting from the HOME page, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > model2701RC- xxx(x) (in the Local Model Code column) > change input mode to Supervisory > Modify Configuration.
The following sections describes the MIB variables that are available on the Model 2701 Configuration—Con- figuration page.
Line Status (lineStatus2701RC) This variable displays the status of the line. There are three possible values that can be displayed:
Software Version (softVersion2701RC) This read-only MIB variable displays the current version of code that is running in the NetLink-E1 rack card modem.
Model 2701 Configuration page MIB variables description 149

Configuration Type (configType) This displays if the 2701RC is using the DIP switch control or software control for its configuration.
Channel Assignment (dsoEnableCh1…dsoEnableCh31) If the 2701RC is operating in G.704 channelized mode, a configurable Channel Assignment table appears. When line format is set to frame-G704(1), individual channels can be either enabled(1) or disabled(0). These options cannot be accessed if line format is set to frame-G703(0).
Unit Configuration table This table shows the configurable MIB variables for the set of units. After changes are made, select the Submit Query button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model 2701 Configuration page.
The following sections explain the MIB variables that are shown in the Unit Configuration table.
Line Format (lineFormat) This option is used to set the line format to the following:
Clock Mode (clockMode2701RC) This variable defines the clock mode for the NetLink-E1 modems. The following options are available:
DTE Rate (dteRate2701RC) This read-only variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of activated channels.
Line Coding (lineCoding2701RC) This variable is used to select the G.703 line coding. The following options are available:
Model 2701 Configuration page MIB variables description 150

CRC4 Framing (crc) This variable is used to enable or disable CRC-4 framing. The following options are available:
CAS Multiframing (casMF) This variable is used to enable or disable CAS multiframing. The following options are available:
Line Build Out (lineBuildOut) This is used to select the line build out. The following options are available:
Tx Clock Timing (txClock) The following options are available:
H/W Test Mode (testModeSetInd) This read-only variable displays any test mode invoked from the toggle switches and DTE test mode lines. If the unit is in a test mode, this option will be highlighted in blue.
Model 2701 Configuration page MIB variables description 151

Software Test Mode (testModeSet2701RC) This is used to invoke test modes through the NMS. Available options are:
RDL Response(v54Loop) The following options are available:
FP Switches (frntSwitch) This selects if the front panel toggle switches used for loopbacks and pattern generators are:
Pattern Select (patternSelect) The following options are available:
Loop Timeout (loopTo) This selects the amount of time that the unit will remain in test mode when the remote test mode is invoked. If the responding unit is not taken out of test mode within this time period, the unit will automatically time out and return to normal data mode.
Model 2701 Configuration page MIB variables description 152

RDL Type (rdlType) This displays the selected remote loopback type that will be used when initiating a remote loopback. Available options are:
Config Type (configType) The following options are available:
Test Mode from DTE (testModeDTE) When enabled, the 2701RC will respond to LL and RDL signals coming from the DTE.
This section describes the MIB variables that are available on the Slot Configuration page. From the Modem Infor- mation page, the address column creates a list of hyperlinks to the Slot Configuration page associated with the spec- ified address. The Slot Configuration page can be used to set slot-specific information related to the system and how the system treats the slot in the case of errors and warning. Starting from the HOME page, click on the follow- ing links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > X (in the Card Address column).
Card Address (nmsSlotID) Displays the address of the card.
Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.
View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).
Local User Id (localUserID) User supplied string that defines the NetLink NTU installed in the rack. The string is stored in non-volatile flash within the NetLink NTU and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within this page.
Slot Configuration page MIB variables description 153
Card Identification Information

Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non- volatile flash within the CP unit. If the unit is moved, the User ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within this page.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warning) associated with the specified slot.
Hardware Reset (resetStatus) Selecting this push button will force the associated modem to perform a hardware reset.
Card Lost Indication (cardLostIndication) This variable allows you to choose what type of indication will be made if a modem is removed from the man- agement system. Three choices are available:
Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. Three choices are available:
Slot Configuration page MIB variables description 154
Alarm Information

Model 2701RC rack cards can be configured globally by templates you create. If you use this capability, you have the option to globally configure some or all Model 2701RC NTUs in multiple racks, or those in just one rack.
This section contains the following information to help you configure and use templates:
Protecting Model 1001 racks and Model 2701RC NTUs from global modification This section describes how to protect 1001 racks and 2701RC NTU cards from being modified when a global modification is applied. This is useful if you are setting all but a few cards to the same configuration. You may protect an entire rack or only selected individual rack cards.
Protecting an entire Model 1001 rack from global configuration Do the following to protect a Model 1001 rack:
Creating and modifying global configuration templates 155


Figure 74. System Level Information page
Creating and modifying global configuration templates 156

The rack is now protected.
Protecting a selected Model 2701RC rack card from global configuration Do the following to protect a single Model 2701RC rack card:
Figure 75. NTU Information Rack 1 page
The rack card is now protected.
Creating and modifying global configuration templates 157

Creating a template This section describes how to create a global configuration template.

Figure 76. Global Configuration Menu page
Do the following to create a template:
Creating and modifying global configuration templates 158

The first table is the Channel Assignment section for activating the DS0 time slots you need (see figure 77). The two options for each channel are:

Figure 77. Channel Assignment table
Creating and modifying global configuration templates 159
– Active(0) · – Inactive(1)

The second part is the Unit Configuration section (see figure 78) for the configuration of the E1 link parame- ters. There are 16 configurable parameters. What follows is a description of them with the available options for each.

Figure 78. Unit Configuration section of the web management table
- frame-G703(0)—This is called either Clear Channel or Transparent mode. The DTE Rate is always
2.408 Mbps and the Channel Assignment table does not affect the configuration when this option is cho- sen.
- frame-G704(1)—This is channelized mode. When selected, the Channel Assignment table directly
determines the DTE Rate.
– There are no configurable options for this parameter, however it is affected by two configurable parame-
ters: the Line Format and the Channel Assignment table.
- lbo-75Ohm(0), when using dual coaxial connections
- lbo-120Ohm(1), when using twisted pair as the transmission medium
Creating and modifying global configuration templates 160

- five11(1)—The 511-bit length pseudo-random test pattern
- two047(2)—The 2047-bit length pseudo-random test pattern
- no-time-out(9)—the loop runs indefinitely and must be turned off manually by the user.
- Switch-config(0)—The 2701RC gets its configuration from the DIP switches on the card
- Software-config(1)—The 2701RC gets its configuration via the software configuration and not the DIP
switches.
- network-CLK(0)—derived from the received signal from the network
- internal-CLK(1)—driven by the internal oscillator in the 2701RC NTU
- external-CLK(2)—provided by DTE External Transmit Clock signal
- code-AMI(1)—primarily in legacy equipment
Creating and modifying global configuration templates 161

- external(0)—Use only when the Clock Mode is set to external-CLK(2).
- internal(1)—Use when the Clock Mode is set to either internal-CLK(1) or networtk-CLK(0).
- disabled (0)—disables the toggle switches on the front panel of the 2701RC rack card
- enabled(1)—enables the ability to use the front panel toggle switches
- disabled(0)—neither loop can be enabled.
- enabled(1)—one of the in-band loops can be enabled depending on the selection of the RDL Type.
- csu(1)—Selects the in-band loop which is initiated as the standard CSU loopback.
- v54(2)—functions as defined by the V.54 remote Loopback.
- disabled(0)—no loopbacks can be initiated by a DTE signal
- enabled(1)—Loopbacks can be initiated by a DTE signal.
Refer to section “Applying a template” on page 164 to activate the template.
Creating and modifying global configuration templates 162

Modifying a template This section describes how to modify a global configuration template.

Figure 79. Global Configuration Menu page
Do the following to modify a template:
Creating and modifying global configuration templates 163


Figure 80. Model 2701RC Global Configuration page
Refer to section “Applying a template” on page 164 to activate the template.
Deleting a template Do the following to delete a template:
Applying a template This section describes how to apply a global configuration to all Model 2701RC rack cards. Model 2701RC cards which will not be configured to the selected Global Configuration are:
Instructions for protecting either an entire rack or individual 2701RC cards are given earlier in this chapter.
Creating and modifying global configuration templates 164

The template can be applied to:
To configure all Model 2701RC rack cards in all Model 1001 racks Complete the following steps.

Figure 81. System Level Information page—System Overview section
The template has been applied.
Creating and modifying global configuration templates 165

To configure all Model 2701RC rack cards in just one Model 1001 rack Complete the following steps:

Figure 82. System Level Information page—Rack section
The template has been applied.
Creating and modifying global configuration templates 166



This chapter describes managing a Model 2707RC NetLink-G.703 network termination unit (NTU) using the Model 1001MC NetLink-NMS internal HTTP/HTML web engine and a standard web browser. This chapter is meant to be used in addition to the manual that came with your unit.
NetLink-NMS description Specifically designed for use in the Patton NetLink system, when the NetLink-G.703 NTU is coupled with the Model 1001MC NetLink-NMS and the Patton Model 1001 rack system, the modem is fully SNMP manageable. SNMP management can be performed on both the local and remote units using a standard SNMP network man- agement station (NMS) or by using a standard web browser and the Model 1001MC's built-in web server. You can view and change configuration variables, view statistical variables, and view error and warning indications.
This section describes the configuration and management of your NetLink G.703 NTUs using a Model 1001MC NetLink-NMS with built in HTTP/HTML web server. If you plan to manage your units using a standard network management station you can download the Patton Enterprise MIBs either through the SNMP web page on the Model 1001MC or obtain them from the Patton web site at www.patton.com.
The following pages are used to configure and manage the Model 2707RC:
Introduction 169

Displaying the Modem Information page The Modem Information page (see figure 83) displays the cards installed in the system and a quick view of any errors or warnings associated with your modems.

Figure 83. Modem Information page for the Model 2707RC
Starting from the HOME page, to access the Modem Information page for the 2707RC, click on the following links: Configure Cards > View Rack 1. Figure 84 on page 171 shows the web page navigation required to get to this area of the system. For more information about items on the Modem Information page, see “Displaying the Slot Configuration page” on page 176.
Configuration and management 170


Figure 84. Web page navigation to Modem Information page
Configuration and management 171

Displaying the Model 2707RC Configuration Slot page The Model 2707RC Configuration Slot page (see figure 85) enables you to make configuration changes to the Model 2707RC and the remote NTU. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Figure 85. Model 2707RC Configuration Slot page
Starting from the HOME page, to access the Model 2707RC Configuration Slot page for the 2707RC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 2707RC you wish to manage (in the example shown in figure 85, the 2707RC was installed in slot 1). Figure 86 on page 173 shows the web page navigation required to get to this area of the system.
Configuration and management 172


Figure 86. Web page navigation to Model 2707RC Configuration Slot page
Making configuration changes to your 2707RC NetLink NTU Do use the following to make configuration changes to your NetLink NTU.
For more information about items on the Model 2707RC Configuration Slot page, see “Model 2707RC Con- figuration Slot page MIB variables description” on page 181.
Configuration and management 173

Displaying the Model 2707RC Configuration—Configuration page The Model 2707RC Configuration—Configuration page (see figure 87) enables you to make configuration changes to the Model 2707RC and the remote CPE box. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Figure 87. Model 2707RC Configuration—Configuration page
Starting from the HOME page, to access the Model 2707RC Configuration—Configuration page for the 2707RC, click on the following links: Configure Cards > View Rack 1 > Local_Model_Code for the 2707RC you wish to manage > Modify Configuration (you first have to change input mode from onLine to superVisoryMode. Figure 88 on page 175 shows the web page navigation required to get to this area of the system.
For more information about items on the Model 2707RC Configuration—Configuration page, see “Model 2707RC Configuration—Configuration page MIB variables description” on page 183.
Configuration and management 174


Figure 88. Web page navigation to Model 2707RC Configuration—Next Configuration page
Configuration and management 175

Displaying the Slot Configuration page The Slot Configuration page (see figure 89) is used to set slot-specific information related to the system and how the system treats that slot in the case of errors or warnings.

Figure 89. Slot Configuration page
Starting from the HOME page, to access the Slot Configuration page for the 2707RC, click on the following links: Configure Cards > View Rack 1 > Card_Address for the 2707RC you wish to manage (in the example shown in figure 89, the 2707RC was installed in slot 1). Figure 90 on page 177 shows the web page navigation required to get to this area of the system.
Configuration and management 176


Figure 90. Web page navigation to Slot Configuration page
For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description” on page 185.
This section describes the MIB variables that are available on the Modem Information page.
Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.
Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.
Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.
Rack Protection Mode If you want to protect all Model 2707RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the pop-up menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.
Modem Information page MIB variables description 177

Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.
Power Supply 1 Status Displays the current status of power supply 1 as one of the following:
Power Supply 2 Status Displays the current status of power supply 2 as one of the following:
Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.
Card Address (nmsSlotID) This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the Model 2707RC Configuration Slot page. This page can be used to set slot-specific information about the card.
Line Status The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:
Modem Information page MIB variables description 178

Warnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more infor- mation on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warning for the slot can be erased in the Slot Configuration page.
Errors (errorCount) This field displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page.
Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.
Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration page for the NetLink modem and its remote unit. The model code information is passed to the Model 1001MC after the card is placed online. The Model 1001MC is auto- sensing, meaning that when a card is found or lost, the information will automatically be updated in the sys- tem. You are not required to setup the Model Code information for each slot. When a card is removed from the system, the Model Code will be erased and an error or warning will be displayed for the slot (this depends on the settings in the Slot Configuration page)
Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non-volatile flash within the CP unit. If the unit is moved, you ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.
Remote Model Code (remoteModelCode) This column displays the model code of the Customer Premise NetLink modem at the far end of the link. This information is communicated from the CP box over the link to the CO Rack Card unit. The NetLink mDSL
Modem Information page MIB variables description 179

rack card will then update the Model 1001MC. For this reason this information will not be available until after the link is made between the two modems.
Protected You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed within the Configure Cards page or from the Slot Configuration page. After clicking the Sub- mit Query button to input the string to the management system, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards web page or from the Slot Configuration page.
Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
Modem Information page MIB variables description 180

This section describes the MIB variables that are available on the Model 2707RC Configuration Slot page.
Model 2707RC Configuration Slot (nmsSlotID) Displays the address of the NetLink E1-G.703 NTU. The address is defined by the DIP-switch setting of S3 and S4 on the rack card.
Line Status (lineStatus) Displays the status of the line. There are three possible values that can be displayed:
Input Mode (mode2707RC) The following settings are available:
To make configuration changes to the NetLink-E1 NTUs, you must first set this bit to superVisoryMode(1). When the Input Mode is set to superVisoryMode(1), the Modify Configuration hyperlink will appear on the web page next to the Refresh Current Page hyperlink. Select the Modify Configuration hyperlink. The Model 2707RC Configuration—Configuration page will appear (see section “Model 2707RC Configuration—Con- figuration page MIB variables description” on page 183 for more information). After making configuration changes to the NetLink-E1 NTUs in the Model 2707RC Configuration page, return to this page and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has com- pleted and will cause it to copy the new configuration into the NetLink-E1 NTU configuration space. If this is not done, the NetLink-E1 NTU will not recognize the configuration changes that were made.
Model 2707RC Configuration Slot X page Configuration Status table description The Configuration Status table shows the configuration for the 2707RC card. If a field is highlighted in yellow, it signifies one of two possible conditions:
The following sections define the MIB variables that are shown in the Configuration Status table.
Model 2707RC Configuration Slot page MIB variables description 181

Configuration Status (configStatus2707RC) Displays the configuration status of the rack card. The following status can be displayed:
Model Code (localModelCode/remoteModelCode) These variables display the local and remote models codes for the units that were found in the specified address.
Line Format (lineFormat) The following status variable can be displayed:
Clock Mode (clockMode2707RC) This variable defines the clock mode for the NetLink-E1 modems. The following status variables can be dis- played:
DTE rate (dteRate2707RC) This variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of acti- vated channels.
Line Coding (lineCoding2707RC) The following status variables can be displayed:
Line Build Out (lineBuildOut) This displays the selected line build out: either 75 ohm or 120 ohm.
FP Switches (frntSwitch) This displays if the front panel toggle switches used for loopbacks and pattern generators are enabled or disabled.
H/W Test mode (testModeSetInd) This displays any test mode invoked from the toggle switches and DTE test mode lines. This option will be highlighted in blue if the unit is in test mode.
S/W Test mode (testModeSet2707RC) This displays any test mode invoked through the NMS. See next configuration for information about invoking test modes through the NMS. This option will be highlighted in blue if the unit is in test mode.
Model 2707RC Configuration Slot page MIB variables description 182

Loop Time Out (loopTo) This displays the amount of time that the unit responding to a Remote Loop command will remain in test mode when the RL test mode is invoked. If the unit is not taken out of test mode by the menu within this time period, the unit will automatically time out and return to normal data mode. The timeout does not apply for loops selected via the front panel switches.
TM from DTE (testModeDTE) This displays if the 2707RC responds to the LL and RDL signals coming from the DTE.
Configuration Type (configType) This displays if the 2707RC is using the DIP switch control or software control for its configuration.
Software Version (softVersion2707RC) This displays the software version of code in the 2707RC.
The Model 2707RC Configuration—Configuration page enables you to update the configuration of the 2707RC NetLink-E1 NTU modems that are installed in the system. After making changes to the configuration on this page, select Back to return to the Model 2707RC Configuration Slot page, then select onLine as the Input Mode, and finally, select Submit Query to send the new information to the Model 1001MC over the net- work.
The following sections describes the MIB variables that are available on the Model 2707RC Configuration— Configuration page.
Line Status (lineStatus2707RC) This variable displays the status of the line. There are three possible values that can be displayed:
Software Version (softVersion2707RC) This read-only MIB variable displays the current version of code that is running in the NetLink-E1 rack card modem.
Configuration Type (configType) This displays if the 2707RC is using the DIP switch control or software control for its configuration.
Model 2707RC Configuration—Configuration page MIB variables description 183

Unit Configuration table This table shows the configurable MIB variables for the 2707RC card. After changes are made, select the Sub- mit Query button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model 2707RC Configuration page.
The following sections explain the MIB variables that are shown in the Unit Configuration table.
Line Format (lineFormat) This option should be set to G.703 unframed: frame-G703(0).
Clock Mode (clockMode2707RC) This variable defines the clock mode for the NetLink-E1 modems. The following options are available:
DTE Rate (dteRate2707RC) This read-only variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of activated channels.
Line Coding (lineCoding2707RC) This variable is used to select the G.703 line coding. The following options are available:
Line Build Out (lineBuildOut) This is used to select the line build out. The following options are available:
FP Switches (frntSwitch) This selects if the front panel toggle switches used for loopbacks and pattern generators are enabled(1) or dis- abled(0).
H/W Test mode (testModeSetInd) This read-only variable displays any test mode invoked from the toggle switches and DTE test mode lines. If the unit is in a test mode, this option will be highlighted in blue.
S/W Test mode (testModeSet2707RC) This is used to invoke test modes through the NMS. The only valid options for the 2707RC are:
Model 2707RC Configuration—Configuration page MIB variables description 184

Loop Timeout (loopTo) This selects the amount of time that the unit will remain in test mode when the remote test mode is invoked. If the responding unit is not taken out of test mode within this time period, the unit will automatically time out and return to normal data mode.
Test Mode from DTE (testModeDTE) When enabled, the 2707RC will respond to the LL signal coming from the DTE.
Config Type (configType) The following options are available:
User Id (UserID) Displays the user-supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.
This section describes the MIB variables that are available on the Slot Configuration page. From the Modem Information page, the address column creates a list of hyperlinks to the Slot Configuration page associated with the specified address. The Slot Configuration page can be used to set slot-specific information related to the sys- tem and how the system treats the slot in the case of errors and warning.
Card Address (nmsSlotID) Displays the address of the card.
Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.
View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).
Local User Id (localUserID) User supplied string that defines the NetLink NTU installed in the rack. The string is stored in non-volatile flash within the NetLink NTU and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within this page.
Slot Configuration page MIB variables description 185
Card Identification Information

Remote User Id (remoteUserID) This feature is not supported by the Model 2707RC NTU.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warning) associated with the specified slot.
Hardware Reset (resetStatus) Selecting this push button will force the associated modem to perform a hardware reset.
Card Lost Indication (cardLostIndication) This variable allows you to choose what type of indication will be made if a modem is removed from the man- agement system. Three choices are available:
Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. Three choices are available:
Slot Configuration page MIB variables description 186
Alarm Information




This chapter describes managing a Model 3088RC NetLink-G.SHDSL network termination unit (NTU) using the Model 1001MC NetLink-NMS internal HTTP/HTML web engine and a standard web browser. This chapter is meant to be used in addition to the manual that came with your unit.
NetLink-NMS description Specifically designed for use in the Patton NetLink system, when the NetLink-G.SHDSL NTU is coupled with the Model 1001MC NetLink-NMS and the Patton Model 1001 rack system, the modem is fully SNMP manage- able. SNMP management can be performed on both the local and remote units using a standard SNMP network management station (NMS) or by using a standard web browser and the Model 1001MC's built-in web server. You can view and change configuration variables, view statistical variables, and view error and warning indica- tions.
This section describes the configuration and management of your NetLink G.SHDSL NTUs using a Model 1001MC NetLink-NMS with built in HTTP/HTML web server. If you plan to manage your units using a standard network management station you can download the Patton Enterprise MIBs either through the SNMP web page on the Model 1001MC or obtain them from the Patton web site at www.patton.com.
The following pages are used to configure and manage the Model 3088RC:
Introduction 190

Displaying the Modem Information page The Modem Information page (see figure 91) displays the cards installed in the system and a quick view of any errors or warnings associated with your modems.

Figure 91. Modem Information page for the Model 3088RC
Starting from the HOME page, to access the Modem Information Rack X page for the 3088RC, click on the fol- lowing links: Home (menu) > Configure Cards (menu) > View Rack [rack number]. Figure 92 on page 192 shows the web page navigation required to get to this area of the system. For more information about items on the Modem Information Rack X page, see “Displaying the Slot Configuration Page” on page 197.
Configuration and management 191


Figure 92. Web page navigation to Modem Information page
Configuration and management 192

Displaying the Model 3088RC Configuration Slot page The Model 3088RC Configuration Slot page (see figure 93) enables you to make configuration changes to the Model 3088RC and the remote NTU. When the page displays, the unit is set to the onLine state and the current configuration is displayed.

Figure 93. Model 3088RC Configuration Slot page
Starting from the HOME page, to access the Model 3088RC Configuration Slot page for the 3088RC, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > model3088RC-xxx(x) (in the Local Model Code column) for the 3088RC you wish to manage (in the example shown in figure 93, the 3088RC was installed in slot 4). Figure 94 on page 194 shows the web page navigation required to get to this area of the system.
Configuration and management 193


Figure 94. Web page navigation to Model 3088RC Configuration Slot page
Making configuration changes to your 3088RC NetLink NTU Do use the following to make configuration changes to your NetLink NTU.
For more information about items on the Model 3088RC Configuration Slot page, see “Model 3088RC Con- figuration Slot X page MIB variables description” on page 201.
Configuration and management 194

Displaying the Model 3088RC Configuration page The Model 3088RC Configuration page (see figure 95) enables you to make configuration changes to the Model 3088RC and the remote CPE box.

Figure 95. Model 3088RC Configuration page
Starting from the HOME page, to access the Model 3088RC Configuration page for the 3088RC, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > model3088RC-xxx(x) (in the Local Model Code column) for the 3088RC you wish to manage > Modify Configuration (you first have to change input mode from onLine to superVisoryMode. Figure 96 on page 196 shows the web page navigation required to get to this area of the system.
For more information about items on the Model 3088RC Configuration page, see “Model 3088RC Configu- ration page MIB variables description” on page 206.
Configuration and management 195


Figure 96. Web page navigation to Model 3088RC Configuration page
Configuration and management 196

Displaying the Slot Configuration Page The Slot Configuration Page (see figure 97) is used to set slot-specific information related to the system and how the system treats that slot in the case of errors or warnings.

Figure 97. Slot Configuration Page
Starting from the HOME page, to access the Slot Configuration page for the 3088RC, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > X in the Card_Address column for the 3088RC you wish to manage (in the example shown in figure 97, the 3088RC was installed in slot 4). Figure 98 on page 198 shows the web page navigation required to get to this area of the system.
Configuration and management 197


Figure 98. Web page navigation to Slot Configuration Page
For more information about items on the Slot Configuration page, see “Slot Configuration page MIB variables description” on page 209.
This section describes the MIB variables that are available on the Modem Information Rack X page. Starting from the HOME page, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number].
Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.
Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.
Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.
Rack Protection Mode (rackXProtected) If you want to protect all Model 3088RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the drop-down menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.
Modem Information Rack X page MIB variables description 198

Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.
Power Supply 1 Status (rackXPower1Down) Displays the current status of power supply 1 as one of the following:
Power Supply 2 Status (rackXPower2Down) Displays the current status of power supply 2 as one of the following:
Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.
Card Address (nmsSlotID) This variable defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is set up using the DIP-switches on the card. The address is also a hyperlink to the Model 1095 Configuration Slot page. This page can be used to set slot-specific information about the card.
Line Status (lineStatus) The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:
Modem Information Rack X page MIB variables description 199

Warnings (warningCount) This field displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more infor- mation on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warning for the slot can be erased in the Slot Configuration page.
Errors (errorCount) This field displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page.
Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page.
Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration page for the NetLink modem and its remote unit. The model code information is passed to the Model 1001MC after the card is placed online. The Model 1001MC is auto- sensing, meaning that when a card is found or lost, the information will automatically be updated in the sys- tem. You are not required to setup the Model Code information for each slot. When a card is removed from the system, the Model Code will be erased and an error or warning will be displayed for the slot (this depends on the settings in the Slot Configuration page)
Remote User Id (remoteUserID)
Remote Model Code (remoteModelCode)
Modem Information Rack X page MIB variables description 200

Protected (disableGlobalConfig) You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed within the Configure Cards page or from the Slot Configuration page. After clicking the Sub- mit Query button to input the string to the management system, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards web page or from the Slot Configuration page.
Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
This section describes the MIB variables that are available on the Model 3088RC Configuration Slot X page. (See figure 93 on page 193). Starting from the HOME page, click on the following links: Home (menu) > Config- ure Cards (menu) > View Rack [rack number] > model3088RC-xxx(x) (in the Local Model Code column).
Model 3088RC Configuration Slot (nmsSlotID) Displays the address of the NetLink E1-G.SHDSL NTU. The address is defined by the DIP-switch setting of S3 and S4 on the rack card.
Model 3088RC Configuration Slot X page MIB variables description 201

Line Status (lineStatus) Displays the status of the line. There are three possible values that can be displayed:
Alarm counters For the four alarm counters, you may choose to do numerous actions upon detecting errors: nothing, incre- ment the counter upon each occurrences of the error, send an SNMP trap, or send a Syslog message. The choice is determined by configuring the Line Down Indicator on the Slot Configuration Page. The following table clarifies what the parameter will do.
Send a Syslog message Increment the Alarm Counter
on the web page Send an SNMP trap
None ✔ Warning ✔ ✔ Error ✔ ✔ ✔
LOS (losAlarm) Displays the number of times Loss of Sync on the E1 line is detected. It is incremented when synchronization to the E1 stream is lost. This number is accumulating in the 1001MC.
Model 3088RC Configuration Slot X page MIB variables description 202

AIS (aisAlarm) Displays the number of times an Alarm Indication Signal on the E1 line is detected. This should be set when an unframed all ones code is received at RPOSI and RNEGI. This number is accumulating in the 1001MC.
Flap Count (lineDownCnt) Displays the number of times the E1 line has been up and then becomes down. This should be set when the E1 line is up and becomes down. This number is accumulating in the 1001MC.
CRC4 Error (crc4Error) Displays the number of CRC4 errors received by the E1 interface. This is an error counter that records word errors in the CRC4. The counter is disabled during loss of sync. This number is accumulating in the 1001MC.
The Clear Counter button This button clears all alarm counters.
Model 3088RC Configuration Slot X page MIB variables description 203

CRC4 Error Alarm Threshold (crc4Threshold) The valid setting for the threshold is 0 to 255. By setting a threshold, the CRC4 Alarm counter will not issue the error/warning, Syslog, and SNMP Trap message unless the accumulating CRC4 Error Counter is greater than the threshold. The Record Current Configuration button will store the setting of the alarm threshold.
Input Mode (mode3088RC) The following settings are available:
To make configuration changes to the NetLink-E1 NTUs, you must first set this bit to superVisoryMode(1). When the Input Mode is set to superVisoryMode1), the Modify Configuration hyperlink will appear. Select the Modify Configuration hyperlink. The Model 3088RC Configuration page will appear (see section “Model 3088RC Configuration page MIB variables description” on page 206 for more information). After making configuration changes to the NetLink-E1 NTUs in the Model 3088RC Configuration page, return to this page by clicking on the Back… hyperlink and place the Input Mode variable back to onLine(0). This will notify the Model 1001MC that the configuration has completed and will cause it to copy the new configuration into the NetLink-E1 NTU configuration space. If this is not done, the NetLink-E1 NTU will not recognize the config- uration changes that were made.
Model 3088RC Configuration Slot page Configuration Status table description The Configuration Status table shows the configuration for the set of units. There are columns for the local and remote units. If a field is highlighted in yellow, it signifies one of two possible conditions:
The following sections define the MIB variables that are shown in the Configuration Status table.
Configuration Status (configStatus3088RC) This is the title of the status table and displays the configuration status of the rack card. The following status can be displayed:
Local Model Code (localModelCode/remoteModelCode) These variables display the local and remote models codes for the units that were found in the specified address.
Model 3088RC Configuration Slot X page MIB variables description 204

DTE Rate (dteRate3088RC) This variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of acti- vated channels.
Clock Mode (clockMode3088RC) This variable defines the clock mode for the NetLink-E1 modems. The following status variables can be dis- played:
TX Clock Invert (tcClockInvert3088RC) • enable(0)
DSL Link Enable (dslLinkEnable3088RC) • enable(0)
Line Probe (lineProbe3088RC) Enables or disables the Line Probe feature to negotiate the optimal rate for current line conditions
Annex Type (annexType3088RC) Sets the DSL annex type
SW Test Mode (testModeSet3088RC) This displays any test mode invoked through the NMS. See next configuration for information about invoking test modes through the NMS. This option will be highlighted in blue if the unit is in test mode.
Front Panel Switches (frontPannelSwitches3088RC) • This variable allows or disallows the front panel switches to cause the unit to go into test mode.
Model 3088RC Configuration Slot X page MIB variables description 205

Response to Test Mode (responseToTestMode3088RC) This variable allows or disallows test modes to be initiated front both the front panel or from the remote unit.
Software Version (softVersion3088RC) This displays the software version of code in the 3088RC.
Reset button Software reset the E-carrier function card on its next poll from 1001MC.
The Model 3088RC Configuration page enables you to update the configuration of the 3088RC NetLink-E1 NTU modems that are installed in the system. After making changes to the configuration on this page, select Back to return to the Model 3088RC Configuration Slot page, then select onLine as the Input Mode, and finally, select Submit Query to send the new information to the Model 1001MC over the network. Starting from the HOME page, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > model3088RC-xxx(x) (in the Local Model Code column) > change input mode to Supervisory > Modify Configura- tion.
The following sections describes the MIB variables that are available on the Model 3088RC Configuration— Configuration page.
DSL Link State (lineStatus3088) This variable displays the status of the line. There are three possible values that can be displayed:
DSL Link State (dSLSyncState3088) This variable displays the status of the line. There are three possible values that can be displayed:
Software Version (softVersion3088RC) This read-only MIB variable displays the current version of code that is running in the NetLink-E1 rack card modem.
Model 3088RC Configuration page MIB variables description 206

Configuration Type (configType) This displays if the 3088RC is using the DIP switch control or software control for its configuration.
Unit Configuration table This table shows the configurable MIB variables for the set of units. After changes are made, select the Submit Query button at the bottom of the table and then place the Input Mode back to onLine(0) in the Model 3088RC Configuration page.
The following sections explain the MIB variables that are shown in the Unit Configuration table.
Clock Mode (clockMode3088RC) This variable defines the clock mode for the NetLink-E1 modems. The following options are available:
DTE Rate (dteRate3088RC) This read-only variable displays the DTE rate for the link. This is the Nx64 kbps data rate selected by the number of activated channels.
TX Clock Invert (tcClockInvert3088RC) • enable(0)
DSL Link Enable (dslLinkEnable3088RC) • enable(0)
Line Probe (lineProbe3088RC) Enables or disables the Line Probe feature to negotiate the optimal rate for current line conditions
Line Coding (lineCoding3088RC) This variable is used to select the G.703 line coding. The following options are available:
Line Build Out (lineBuildOut) This is used to select the line build out. The following options are available:
Model 3088RC Configuration page MIB variables description 207

Tx Clock Timing (txClock) The following options are available:
Model 3088RC Configuration page MIB variables description 208

Software Test Mode (testModeSet3088RC) This is used to invoke test modes through the NMS. Available options are:
RDL Response(v54Loop) The following options are available:
FP Switches (frntSwitch) This selects if the front panel toggle switches used for loopbacks and pattern generators are:
This section describes the MIB variables that are available on the Slot Configuration page. From the Modem Infor- mation page, the address column creates a list of hyperlinks to the Slot Configuration page associated with the spec- ified address. The Slot Configuration page can be used to set slot-specific information related to the system and how the system treats the slot in the case of errors and warning. Starting from the HOME page, click on the follow- ing links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > X (in the Card Address column).
Card Address (nmsSlotID) Displays the address of the card.
Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.
View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).
Local User Id (localUserID) User supplied string that defines the NetLink NTU installed in the rack. The string is stored in non-volatile flash within the NetLink NTU and is useful for hardware identification. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within this page.
Slot Configuration page MIB variables description 209
Card Identification Information

Remote User Id (remoteUserID) User supplied string that defines the Customer Premise box at the far end of the link. The string is stored in non- volatile flash within the CP unit. If the unit is moved, the User ID will move to the new slot making it useful for hardware identification. The string can be up to 10 bytes long and can be changed or reset within this page.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warning) associated with the specified slot.
Hardware Reset (resetStatus) Selecting this push button will force the associated modem to perform a hardware reset.
Card Lost Indication (cardLostIndication) This variable allows you to choose what type of indication will be made if a modem is removed from the man- agement system. Three choices are available:
Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. Three choices are available:
Slot Configuration page MIB variables description 210
Alarm Information

Model 3088RC rack cards can be configured globally by templates you create. If you use this capability, you have the option to globally configure some or all Model 3088RC NTUs in multiple racks, or those in just one rack.
This section contains the following information to help you configure and use templates:
Protecting Model 1001 racks and Model 3088RC NTUs from global modification This section describes how to protect 1001 racks and 3088RC NTU cards from being modified when a global modification is applied. This is useful if you are setting all but a few cards to the same configuration. You may protect an entire rack or only selected individual rack cards.
Protecting an entire Model 1001 rack from global configuration Do the following to protect a Model 1001 rack:
Creating and modifying global configuration templates 211


Figure 99. System Level Information page
Creating and modifying global configuration templates 212

The rack is now protected.
Protecting a selected Model 3088RC rack card from global configuration Do the following to protect a single Model 3088RC rack card:
The rack card is now protected.
Creating and modifying global configuration templates 213

Creating a template This section describes how to create a global configuration template.

Figure 100. Global Configuration Menu page
Do the following to create a template:
Creating and modifying global configuration templates 214

Figure 101 is the Unit Configuration section (see figure 101) for the configuring E1 link parameters. There are 16 configurable parameters. What follows is a description of them with the available options for each.

Figure 101. Unit Configuration section of the web management table
- network-CLK(0)—derived from the received signal from the network
- internal-CLK(1)—driven by the internal oscillator in the 3088RC NTU
- external-CLK(2)—provided by DTE External Transmit Clock signal
Creating and modifying global configuration templates 215

- none(0)-No test mode in process
- lal(1)-Local loopback test
- disabled (0)—disables the toggle switches on the front panel of the 3088RC rack card
- enabled(1)—enables the ability to use the front panel toggle switches
- disabled(0)—no loopbacks can be initiated by a DTE signal
- enabled(1)—Loopbacks can be initiated by a DTE signal.
Refer to section “Applying a template” on page 217 to activate the template.
Modifying a template This section describes how to modify a global configuration template.

Figure 102. Global Configuration Menu page
Do the following to modify a template:
Creating and modifying global configuration templates 216
- rdl(2)-Remote loopback

Refer to section “Applying a template” on page 217 to activate the template.
Deleting a template Do the following to delete a template:
Applying a template This section describes how to apply a global configuration to all Model 3088RC rack cards. Model 3088RC cards which will not be configured to the selected Global Configuration are:
Instructions for protecting either an entire rack or individual 3088RC cards are given earlier in this chapter.
The template can be applied to:
To configure all Model 3088RC rack cards in all Model 1001 racks Complete the following steps.
Creating and modifying global configuration templates 217


Figure 103. System Level Information page—System Overview section
The template has been applied.
Creating and modifying global configuration templates 218

To configure all Model 3088RC rack cards in just one Model 1001 rack Complete the following steps:

Figure 104. System Level Information page—Rack section
The template has been applied.
Creating and modifying global configuration templates 219





Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
This section describes how to navigate the internal HTTP/HTML web pages on the Model 1001MC. The diagram below shows how all of the web pages are linked together. Following figure 105, there is a brief description of each page.

Figure 105. 1001MC command map
Figure 106. 1001MC login window
Login After typing the IP address into your web browser as the URL, the Model 1001MC will present the login screen (see figure 106). The Model 1001MC has two levels of password protection, superuser and monitor. The Model 1001MC has two levels of password protection:
Introduction 224

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
After logging in, the system displays the HOME page (see figure 107).
Figure 107. HOME page
HOME The HOME page displays a quick overview of the system including; error and warning indications, software information, box names, number of modems installed, and so on.
On the left side of the HOME page is the Navigation View. The list on the left side of the screen allows you to navigate to any page from this point. The navigation page will always be available to you so you can change from one page to the next.
The Record Current Configuration button lets you store configuration changes made to the box.
Introduction 225

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
The Hard Reset button forces the 1001MC to perform a reset. This will not reset the individual cards in the rack only the 1001MC. If you would like to perform a hardware reset on the individual cards, refer to the Slot Configuration page.
See section “HOME” on page 228 for more information.
About 1001MC The About 1001MC page gives a more in-depth overview of the system that presented on the HOME page. This page also provides contact information about Patton Electronics. See section “About 1001MC” on page 231 for more information.
Import/Export The Import/Export function enables you to make a backup (or export) copy of the 1001MC rack’s configura- tion parameters. By exporting the configurations,l the saved files can quickly be loaded, or imported, into a replacement 1001MC rack—greatly speeding up the installation process should a rack need to be replaced. Additionally, you may have multiple racks requiring the same configuration. This simplifies and accelerates the installation.

Figure 108. The Import/Export web management page.
Configure Cards Clicking on the Configure Cards hyperlink displays the System Level Information page. This page is the starting point for the configuration and management of your Patton NetLink modems. This page enables you to quickly identify potential problems and view statistics on a per-rack basis. You can also disable racks from this level. For more information, see section “System Level Information” on page 235.
Introduction 226

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
From this page, you can select a View Rack hyperlink that will display the Modem Information Page for the selected rack.
Modem Information Page The Modem Information Page consists of a table that displays top level information about the cards installed in the selected rack. These items include; model codes, user IDs, errors and warning, and circuit IDs. This page also allows you to gain information about the number of cards and power supplies in the rack. (See section “Modem Information Rack X” on page 239 for more information).
From this page there are two hyperlinks that can be selected that will give you detailed information about a specific modem. These are the Slot Configuration hyperlink, shown as the address of the card in the table, and the Modem Statistics hyperlink, shown as the local model code.
Slot Configuration. The Slot Configuration page enables you to enter information about the modem installed. From the page, you can change the User IDs, Circuit IDs, and the Error and Warning Indications. From this page, you can also clear errors and warning and perform a hardware reset on the modem installed in the rack (see section “Slot Configuration” on page 243 for more information).
Modem Statistics. The Modem Statistics page shows the current configuration and statistical state of the local and remote modem installed at the selected address. From this page, you can place the card into the superVisoryMode. Once the card is in this mode, the web page will display a hyperlink that will allow you to enter the Modem Configuration Page.
Modem Configuration Page. The Modem Configuration page allows you to change the configuration of the local and remote modems installed at the selected address. This page can also be used to place the cards into test modes. Once the configuration has been setup, submit the changes, then return to the Modem Statistics page to place the modem into the onLine state.
System Information You can navigate to the System Information page by selecting the hyperlink along the left side of any page. The System Information page enables you to setup the IP information, box information, and password information for the system. It is recommended that you change your passwords immediately after installing your Model 1001MC to ensure security for your network (see section “System Information” on page 246 for more information).
Download The Download page enables you to perform software upgrades on the 1001MC itself, and the 1094ARC and 1095RC NetLink rack card modems installed in the system. New software can be obtained from Patton Electron- ics via a file-transfer protocol (FTP) connection (see section “Download” on page 249 for more information).
System Log The System Log page displays Syslog messages. Syslog messaging is a reporting tool used in the Model 1001MC to log run-time operations. There are several levels of messages and you can set the system to report only messages above a certain level. From this page, you can reach the Syslog—Modify, Modify—Volatile Memory, and Mod- ify—Non-Volatile Memory web pages. See section “System Log” on page 251 for more information about the System Log page.
Introduction 227

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Syslog—Modify The Syslog—Modify web page allows you to setup the configuration for the Syslog messaging system. You can set variables such as the IP address of a Syslog Daemon and priority levels for each of the messaging facilities (see section “System Log—Modify” on page 252 for more information).
Syslog—Volatile Memory The Syslog—Volatile Memory page displays Syslog messages that have been sent to the Volatile Memory sec- tion of the messaging system. The messages stored here will be lost if the system is re-booted (see section “Sys- tem Log—Volatile Memory” on page 256 for more information).
Syslog—Non-Volatile Memory The Syslog—Non-Volatile Memory page displays Syslog messages that have been sent to the Non-Volatile Memory section of the messaging system. The messages stored here will be stored in Flash memory and will be available if the system is re-booted or power is lost (see section “System Log—Non-Volatile Memory” on page 257 for more information).
SNMP The SNMP web page enables you to download the Patton Enterprise MIBs for the Model 1001MC. These MIBs are required if you plan to manage the system using a network management station (NMS) instead of the web page manager.
The HOME page is the first HTTP/HTML screen that you will reach after you log into the Model 1001MC (see figure 107 on page 225). From the HOME page you may monitor the current system status, save any sys- tem changes or reset the system without powering off the rack system.

Figure 109. Box information
There are six system variables which describe information about the 1001MC. These variables are shown in figure 109, and are described in the following sections.
Software Version (boxSoftwareVersion) This variable defines the version of the software currently running in the Model 1001MC. The Model 1001MC can be software upgraded using an FTP download.
Software Date Code (boxDateCode) This variable defines the date and time the software was compiled.
Box information

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Box Name (boxName) This variable displays a user defined string that represents the name of the box. This variable can be changed by the user in the System Info web page.
Box Contact (boxContact) This variable displays a user defined string that represents the contact for the box. You can change this variable in the System Info web page.
Box Location (boxLocation) This variable displays a user defined string that represents the location of the box. You can change this variable in the System Info web page.
Running Since Last Boot (boxUpTime) This variable tells you how long the Model 1001MC has been running since it was last reset.

Figure 110. Operating status variables
Operating status variables There are four system variables which describe the immediate operating status of the NetLink modems installed in the rack. These variables are shown in figure 110 and are described in the following sections.
Total System Slots Available (totalConfigSlots) This read-only variable defines the largest address that the system will POLL (address 1 to totalConfigSlots). Any NetLink modem with an address outside of this range will not be found by the Model 1001MC.
Total Active Slots (totalActiveSlots) This read-only variable defines the number of NetLink modems currently installed in the system. As the Model 1001MC brings the modems online this number is incremented. After a card is removed from the system, this number is decrement.
Total System Warnings (boxWarningNumber) This variable defines the number of warnings that are currently outstanding in the system. This number includes warnings that have been generated from the NetLink modems as well as the Model 1001MC itself. If this number is greater than zero, this field will be highlighted in yellow to notify you that the warning exists. Warnings are cleared through the Configure Cards web page for the system, or the Slot Configuration page for the individual modems. You can view the System Log page to examine the source of the warnings.
Total System Errors (boxErrorNumber) This variable defines the number of errors that are currently outstanding in the system. This number includes errors that have been generated from the NetLink modems as well as the Model 1001MC itself. If this number is greater than zero, this field will be highlighted in red to notify you that the errors exists. Errors are cleared

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
through the Configure Cards web page for the system, or the Slot Configuration page for the individual modems. You can view the System Log page to examine the source of the warnings.

Figure 111. Immediate actions
Immediate Actions There are several immediate actions which can be executed on the Model 1001MC, when in superuser mode (see figure 111), which will cause the box to act according to the following:

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Figure 112. About 1001MC
The About 1001MC link displays system information and the following Patton Electronics Company contact information:
Patton Electronics Co. 7622 Rickenbacker Drive Gaithersburg, Maryland 20879, U.S.A.
About 1001MC 231

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Figure 113. System Level Information page
About 1001MC 232

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
The Import/Export function enables you to make a backup (or export) copy of your Model 1001MC’s configura- tion parameters. By exporting the configurations, the saved files can quickly be loaded, or imported, into a replace- ment Model 1001MC—greatly speeding up the installation process should the Model 1001MC need replacing.
To import or export a configuration, click on Import/Export under the Configuration Menu to display the Import/Export main window (see figure 114).
Figure 114. Import/Export main window
Export Configuration · Import Export 233

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
To export the flash configuration, click on the Export Flash link on the Import/Export main page. The Model 1001MC will display text configuration information resembling that shown in figure 115.

Figure 115. Typical access server flash memory configuration data
To save the displayed data as a text file, select the Save option on your browser (see figure 116). For example, under Netscape, select File > Save As. A dialog box will display enabling you to save the contents of the export parameters to a text file. Select the location where you want the file stored, type a file name, and click Save.

Figure 116. Saving the access server flash memory configuration data as a text file
Import Export 234

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Import Configuration To import a configuration file into the access server, type the complete path and filename for the configuration file you wish to load or click on the Browse… button to select the desired file, then click on the Submit Query button (see figure 114 on page 233).
Upon successfully importing the file, the access server will display Configuration Load Complete, indicating that the new operating parameters have been loaded into flash memory.
Click on HOME under the Configuration Menu, then click on the Hard Reset button under Immediate Actions.
Clicking the Configure Cards hyperlink on the HOME page displays the System Level Information page. Figure 113 displays a portion of the information page for the NetLink system being managed. The System Level Information page contains statistical information about the entire system and explains how that information is broken down among the racks. Each rack can be enabled or disabled from this level. When a rack is disabled, the 1001MC stops polling the addresses contained in the specified rack. The 1001MC’s ability to stop polling is use- ful when installing less than eight racks or when taking cards offline in order to perform servicing. The modems installed in the system will continue to operate at the last setting provided. This page also allows you to clear alarms on a per-rack or system basis. Each rack view also contains a View Rack hyperlink to the Modem Informa- tion page (see section “Modem Information Rack X” on page 239 for more information). The following sections describe the variables contained within the System Level Information page.
System Overview This section of the System Level Information window (see figure 113 on page 232) does the following:
Apply System Configuration If you are applying a global configuration to all Model 1095RC, 2701RC, and 2707RC rack cards in the sys- tem, select the desired template from the pop-up menu, then click the Apply Configuration button. For more information about the system configuration feature (including how to protect rack cards and racks from being modified), refer to section “System Config” on page 259.
System Level Information 235

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Apply System Test Mode If you are going to be running in system test mode, select one of the following test patterns from the pop-up menu, then click the Apply Test Mode button.
Total Slots Available (totalConfigSlots) Displays the number of configurable slots available in the system.
Total Cards Installed (totalActiveSlots) Displays the number of cards the system has found.
Power Supplies Installed (boxPowerSupplies) Displays the number of power supplies installed in the system.
Total System Warnings (boxWarningNumber) Displays the number of warnings that have been generated by the system.
Total System Errors (boxErrorNumber) Displays the number of errors that have been generated by the system.
Clear All System Alarms (clearAlarms) Click on this button to clear alarms for the entire system.
Rack X Top Level The following variables are used by each rack in the system. Replace the X shown in the variable name with the appropriate rack number to label the specific variable name (i.e. rack2Enable).
System Level Information 236

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Rack X Enable (rackXEnable) This is where you can enable or disable a rack for use by the system. You will almost always want to have the rack enabled, but it can be useful to disable a rack if:
View Rack X hyperlink Click on this link to display the Modem Information Rack X page. The Modem Information Rack page displays an overview of the NetLink rack that is being managed. For more information, refer to section “Modem Informa- tion Rack X” on page 239.
Address Range Displays the addresses (in groups of 15) that will be polled for the defined rack (for example, the address range for rack 1 would be 1-15, rack 2 would be 16-30, and so on).
Total Slots Available (rackXSlotsAvailable) Displays the number of slots available for the rack (based on the number of power supplies installed in the rack).
Total Cards Installed (rackXCardsInstalled) Displays the number of cards that the system has found.
Power Supplies Installed (rackXPowerSupplies) Displays the number of power supplies installed in the rack (this value determines the addressing range for the rack).
Total Errors (rackXErrorNumber) Displays the number of errors that have been reported by the system for this rack.
Total Warnings (rackXWarningNumber) Displays the number of warnings that have been reported by the system for this rack.
Apply Rack Configuration If you are applying a global configuration to Model 1095RC, 2701RC, and 2707RC rack cards installed in the rack, select the desired template from the pop-up menu, then click the Apply Configuration button. For more information about the system configuration feature (including how to protect rack cards from being modified), refer to section “System Config” on page 259.
System Level Information 237

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Apply Test Mode If you are going to be running in test mode, select one of the following test patterns from the pop-up menu, then click the Apply Test Mode button.
Rack Protection Mode If you want to protect all Model 1095RC rack cards installed in the current rack from being globally config- ured, select protected(1) from the pop-up menu, then click the Apply Protection button. For more information about the system configuration feature, refer to section “System Config” on page 259.
Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms reported by the system for this rack.
System Level Information 238

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
The Modem Information Rack X page displays an overview of the NetLink rack that is being managed. This page will display statistical information, such as errors and warnings on a per-card basis, and identification information, such as model codes and user IDs. Figure 117 shows the Modem Information page, a description of each variable follows.

Figure 117. Modem Information page
Slots Available (totalConfigSlots) Displays the number of configurable slots available in the rack.
Modems Installed (rackXCardsInstalled) Displays the number of modem cards installed in the rack that the system has found.
Number of Power Supplies (rackXPowerSupplies) This is where you specify the number of power supplies installed in the rack (this value determines the addressing range for the rack). In the case of a redundant power supply system, you should set this variable to 2, this will inform the Model 1001MC that there should be 2 power supplies in the system.
Modem Information Rack X 239

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Rack Protection Mode If you want to protect all Model 1095RC, 2701RC, and 2707RC rack cards installed in the current rack from being globally configured, select protected(1) from the pop-up menu, then click the Submit button. For more information about the system configuration feature, refer to section “System Config” on page 259.
Submit button After you have defined the number of power supplies installed in the rack and the rack protection mode, click on the Submit button to save the changes.
Power Supply 1 Status Displays the current status of power supply 1 as one of the following:
Power Supply 2 Status Displays the current status of power supply 2 as one of the following:
Clear Rack X Alarms (clearAlarms) Click on this button to clear alarms for the current rack.
Card Address (nmsSlotID) Defines the address of the card. The Model 1001MC will poll the cards using the addresses listed in the Card Address column. If a modem is found with the same address, it will be displayed in that row. The address of the card is setup using the DIP-switches on the card. For more information about setting the address of a card, please refer to the appropriate NMS version of the manual for the specific NetLink modem. The address is also a hyperlink to the Slot Configuration page (see section “Slot Configuration” on page 243 for more informa- tion). This page can be used to set slot specific information about the card.
Modem Information Rack X 240

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Line Status The line status column on each View Rack page shows the current line status of each card. Keep in mind that the more cards the 1001MC is managing, the longer it will take for the line status field to update. Displays the status of the line. The following values can be displayed:
Warnings (warningCount) Displays the warnings that are associated with each modem installed in the system. When warnings are present, this field will be highlighted in yellow and the number of warnings will be listed. For more information on the cause of the warning, you should view the System Log. Warnings will be highlighted in yellow in the log. The warnings for the slot can be erased in the Slot Configuration page (see section “Slot Configuration” on page 243 for more information).
Errors (errorCount) Displays the errors that are associated with each modem installed in the system. When errors are present, this field will be highlighted in red and the number of errors will be listed. For more information on the cause of the error, you should view the System Log. Errors will be highlighted in red in the log. The errors for the slot can be erased in the Slot Configuration page (see section “Slot Configuration” on page 243 for more information).
Local User Id (localUserID) User supplied string that defines the NetLink modem installed in the rack. The string is stored in non-volatile flash within the NetLink modem. If the address of the modem is changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page (see section “Slot Configuration” on page 243 for more information).
Local Model Code (localModelCode) This column displays the model code of the NetLink modem installed at the specified address. The Model Code is also a hyperlink into the configuration of the NetLink modem and its remote unit. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page (see section “Slot Configu- ration” on page 243 for more information)
Remote User Id (remoteUserID) User supplied string that defines the unit at the end of the link. The string is stored in non-volatile flash within the unit. If the unit is moved, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or reset within the Slot Configuration page (see section “Slot Configuration” on page 243 for more information).
Modem Information Rack X 241

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Remote Model Code (remoteModelCode) This column displays the model code of the NetLink modem at the far end of the link.
Protected You can protect individual rack cards from being globally configured by setting the pop-up menu from nor- mal(0) to protected(1). After you have set the protection option, if you are finished making changes to the cur- rent rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards page or from the Slot Configuration page (see section “Slot Config- uration” on page 243 for more information). After you have set the local circuit ID, if you are finished making changes to the current rack card, click on the Submit button (located at the right side of the rack card’s row in the table) to save the changes.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string can be changed from the Configure Cards page or from the Slot Configuration page (see section “Slot Config- uration” on page 243 for more information).
Submit button Click the Submit button to input the changes to the management system. After clicking the Submit button, you are required to select the Record Current Configuration button on the Model 1001MC button on the Model 1001MC HOME page. This will store the information into flash making it available after a re-boot or power cycle.
Modem Information Rack X 242

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
The Slot Configuration page (see figure 118) enables you to make slot specific configuration changes that are not product specific. The following sections describe each variable.
Figure 118. Slot Configuration Page
Card Address (nmsSlotID) Displays the address of the card.
Local Model Code (localModelCode) Displays the model code of the NetLink modem installed at the specified address.
View Rack X hyperlink Click on the View Rack X link to display the Modem Information Rack X window (see section “Modem Infor- mation Rack X” on page 239 for more information).
Local User Id (localUserID) 10-byte user-supplied string that defines the NetLink modem installed in the rack. The string is stored in non- volatile Flash within the NetLink modem. If the address of the modem is changed, the User ID will move to the new slot.
Card Identification Information · Slot Configuration 243

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
To configure the local user ID, type the ID into the Local User ID text box, then click the Submit button {located next to the Remote User ID text box) to save the changes.
Clear Local ID button. If you want to delete the local ID information, click on the Clear Local ID button, then click on the Submit button.
Remote User Id (remoteUserID) 10-byte user supplied string that defines the remotely connected modem. The string is stored in non-volatile Flash within the NetLink modem.
To configure the remote user ID, type the ID into the Remote User ID text box, then click the Submit button {located next to the Remote User ID text box) to save the changes.
Clear Remote ID button. If you want to delete the remote ID information, click on the Clear Remote ID button, then click on the Submit button.
Local Circuit ID (localCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile Flash within the Model 1001MC.
To configure the local circuit ID, type the ID into the Local Circuit ID text box, then click the Submit button {located next to the Local Circuit ID text box) to save the changes.
Clear Local Circuit ID button. If you want to delete the local circuit ID information, click on the Clear Local Circuit ID button, then click on the Submit button.
Remote Circuit ID (remoteCircuitID) The circuit ID is a 40-byte string that is stored in non-volatile Flash within the Model 1001MC.
Slot Configuration 244

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
To configure the remote circuit ID, type the ID into the Remote Circuit ID text box, then click the Submit but- ton {located next to the Remote Circuit ID text box) to save the changes.
Clear Remote Circuit ID button. If you want to delete the remote circuit ID information, click on the Clear Remote Circuit ID button, then click on the Submit button.
Clear Slot Alarms (resetStatus) Selecting this push button erases the alarms (errors and warnings) associated with the specified slot.
Hardware Reset (resetStatus) Selecting this button will force the current rack card modem to perform a hardware reset.
Card Lost Indication (cardLostIndication) This variable lets you choose what type of indication will be made if a modem is removed from the manage- ment system. The following options are available:
Line Down Indication (lineDownIndication) This variable allows you to choose what type of indication will be made if a modem reports a line down sce- nario. The following options are available:
Alarm Information · Slot Configuration 245

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
The System Information page (see figure 119) displays the current setting for the system. This page allows you to setup parameters defining password protection and the network address. A description of each variable follows figure 119.

Figure 119. System Information
IP Address (boxIpAddress) Displays the IP address of the box.
IP Mask (boxIpMask) Displays the IP mask of the box.
Current Gateway (boxGateway) Displays the current gateway for the network.
Current System Information · System Information 246

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Modifying the IP addressing
IP Address (boxIpAddress) This parameter defines the IP address of the box. Type the address into the text box, then, if you have no other IP addressing entries to make, click the Submit button.
IP Mask (boxIpMask) This parameter defines the IP mask of the box. Type the address into the text box, then, if you have no other IP addressing entries to make, click the Submit button.
Gateway (boxGateway) This parameter defines the current gateway for the network. Type the address into the text box, then, if you have no other IP addressing entries to make, click the Submit button.
Box Location (boxLocation) User defined string that represents the location of the box. This variable is displayed on the HOME page.
Type the box location into the text box, then, if you have no other box contact entries to make, click the Sub- mit button.
Box Name (boxName) User defined string that represents the name of the box. This variable is displayed on the HOME page.
Type the box name into the text box, then, if you have no other box contact entries to make, click the Submit button.
Box Contact (boxContact) User defined string that represents the contact for the box. This variable is displayed on the HOME page.
Type the box contact information into the text box, then, if you have no other box contact entries to make, click the Submit button.
SNMP and HTTP Password Information
Superuser Password (boxSnmpMasterPassword) This password will allow full access rights to the box (read-write). Change the password by typing the new password into the Superuser Password and Superuser Password Verification fields, then click the Submit button.
Box Contact Information · System Information 247

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
User Password (boxSnmpMonitorPassword) This password will allow monitor access rights to the box (read-only). Change the password by typing the new password into the User Password and User Password Verification fields, then selecting the Submit button.
Background Information (boxBackgroundFlag) The Model 1001MC contains a background image that can be used while viewing the web pages. You can choose to enable or disable the background image, then click on the Submit button to apply the change.
Web Page Refresh Rate (BoxWebRefreshRate) The user may choose to refresh certain web configuration pages at various rates or no automatic refresh. The following pages are refreshed at the rate selected:
The user’s selection of auto refresh rates are:
System Information 248

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Web Background Enabled (boxBackgroundFlag) The Model 1001MC contains a background image that can be used while viewing the web pages. You can choose to enable or disable the background image, then click on the Submit button to apply the change. The two options are:
Figure 120. Download page
The Model 1001MC has the facilities to download new Flash software into itself and the following NetLink modems:
Upgrading 1001MC software via FTP download This section describes how to upgrade the Flash memory in the Model 1001MC. You will need the following:
Download 249

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
ftp where <IP ADDRESS> is the IP address of the 1001MC.
The 1001MC will respond with the following:
Connected to
220 Code download service ready
User ( < IP ADDRESS > (none)):
The 1001MC will respond with the following:
331 User name okay, need password.
Password:
The 1001MC will respond with the following:
230 User logged in, proceed.
FTP> “type image” The 1001MC will respond with the following:
200 Command okay.
The 1001MC will respond with the following:
Response: 200 Command okay.
150 File status okay; about to open data connection.
226 Closing data connection.
Connection closed by remote host.
There will be a few second delay after the data connection is opened while the file is being transferred, then the connected will be closed. The 1001MC will automatically install the new software.
Download 250

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Figure 121. System Log
The System Log page (see figure 121) displays an overview of the system logging functions. The system log is a messaging system that stores information about the system as it is running. The following hyperlinks are avail- able for modifying and viewing system log messages:
System Log 251

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Figure 122. System Log—Modify
The System Log—Modify page (see figure 122) allows you to modify the system log parameters. You can choose which messages will be sent to the available message logging functions.
Syslog Daemon IP Address (syslogDaemonIP) The Model 1001MC can send messages over a network to a Syslog Daemon. This variable specifies the IP address that will be running the Syslog Daemon. Type the IP address into the text box, then click the Submit button.
Daemons · System Log—Modify 252

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
SNMP Trap Daemon IP Address (syslogTrapIP) SNMP traps are generated for line down, line up, card lost, power supply 1 fail, and power supply 2 fail events. The specific trap numbers are as follows:
Trap Description Specific Trap Number
TRAP_ID_POWER_ONE_FAIL 1 TRAP_ID_POWER_TWO_FAIL 2 TRAP_ID_CARD_LOST 3 TRAP_ID_LINE_UP 4 TRAP_ID_LINE_DOWN 5
The Trap IP address is assigned on the System Log page. If the IP address is assigned, SNMP traps will be sent to that IP address. For line up and line down traps, Line down indication has to be set to error(2) on the Slot Configuration page for each card (see section “Slot Configuration” on page 243).
The line up, line down, and card lost trap messages will include the box name, rack number, card number in that rack, and local circuit ID in the trap string followed by a description of the trap. For example, the string in a line up trap will resemble: Model 1001MC Demo, Rack Number: 1, Card Number: 12, Local Circuit ID: Test Circuit, Line Up Addr: 12.
Type the IP address into the text box, then click the Submit button.
Min Priority for SysLog Daemon Specify the minimum priority for a message that will be sent to the SysLog Daemon. The following options are available:
For most situations, set the outputs that are being used to prioritySystem(80). For unused output mechanisms, set the priority to priorityDisable(1000). Select the priority setting from the pop-up menu, then click the Sub- mit button.
Priority · System Log—Modify 253

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Min Priority for Flash Storage Specify the minimum priority for a message that will be sent to Flash storage. The following options are available:
For most situations, set the outputs that are being used to prioritySystem(80). For unused output mechanisms, set the priority to priorityDisable(1000). Select the priority setting from the pop-up menu, then click the Sub- mit button.
Min Priority for RAM Specify the minimum priority for a message that will be sent to RAM. The following options are available:
For most situations, set the outputs that are being used to prioritySystem(80). For unused output mechanisms, set the priority to priorityDisable(1000). Select the priority setting from the pop-up menu, then click the Sub- mit button.
System Log—Modify 254

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
uration changes into memory (see “HOME” on page 228 for more information).
Unix Facility Specify the minimum priority for a message that will be sent to Flash storage. The following options are available:
Select the facility setting from the pop-up menu, then click the Submit button.
System Log—Modify 255

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Maintain Flash Storage (syslogFlashClear) This variable is used to notify you about the status of the flash storage area. The following options are available:
The System Log—Volatile Memory page (see figure 123) contains a log of messages that have been sent to the RAM storage area using the Min Priority for RAM variable in the Syslog Modify page. Messages stored here will be lost if the box reboots.

Figure 123. System Log—Volatile Memory
System Log—Volatile Memory 256
Maintenance

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
The System Log—Volatile Memory page (see figure 124) contains a log of messages that have been sent to the flash storage are using the Min Priority for Flash Storage variable in the Syslog Modify page. Messages stored here will be saved even if the box reboots. This page will show warnings highlighted in yellow and errors high- lighted in red. When an error or warning is displayed somewhere in the web pages, this page will give a descrip- tion of the error/warning. All information on this page is read-only except a single push button at the top of the page which is described in more detail below.

Figure 124. System Log—Non-Volatile Memory
Erase Flash Messages (syslogFlashClear) Clicking on this button clears messages listed on the page. This function can also be performed from the Sys- log Modify page.
System Log—Non-Volatile Memory 257

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
The SNMP Support Page (see figure 125) is where you can download the MIBs used by the 1001MC. You will need the MIBs if you will be using an SNMP Network Management Station and a standard SNMP software package or MIB walking tool to manage your Patton NetLink System instead of the built-in NetLink-NMS HTTP/HTML management pages.

Figure 125. SNMP Support Page
The following options are available:

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Model 1095RC, 2701RC, and 2707RC rack cards can be configured globally by templates you create. If you use this capability, you have the option to globally configure some or all Model 1095RC, 2701RC, and 2707RC modems in multiple racks, or those in just one rack.
This section contains the following information to help you configure and use templates:
Protecting Model 1001 racks and Model 1095RC modems from global modification This section describes how to protect 1001 racks and 1095RC modem cards from being modified when a glo- bal modification is applied. This is useful if you are setting all but a few cards to the same configuration.
Select the appropriate option from following configuration choices:
System Config 259

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Protecting a Model 1001 rack from global configuration Do the following to protect a Model 1001 rack:
Figure 126. System Level Information page
System Config 260

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Figure 127. Web page navigation to System Level Information page
The rack is now protected.
System Config 261

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Protecting a Model 1095RC rack card from global configuration Do the following to protect a single Model 1095RC rack card:

Figure 128. Modem Information Rack 1 page

Figure 129. Web page navigation to Modem Information Rack 1 page
System Config 262

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
The rack card is now protected.
Creating a template This section describes how to create a global configuration template. The Patton Model 1095 enables the Model 1001MC system administrator to configure the units for a wide variety of applications. Due to the many different applications that are supported, care must be taken when setting the configuration of your modems. There are several illegal combinations of variables that could cause problems with the modems if implemented incorrectly. Be sure to read the following information before creating a template:
After reviewing the rules and notes, go to section “Procedure for creating a template” on page 265 to learn how to create a template.
Configuration rules Keep in mind the following when creating a template:
System Config 263

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
There are special situations which would require the use of the external-external(4) clock mode setting. This setting should only be used when the application has an IM2RC/K and a 1095RC in the rack system and a IM1/K and a 1095 standalone at the remote site. If you are using any other interface cards do not use the exter- nal-external(4) configuration.
Notes on framing mode settings The Framing Mode Setting notifies the card of the type of interface it will be connected to. When you are using an IM2RC/K with a 1095RC rack card, the system administrator should set the Local Clock Mode to external (either external-receiveRecover(1) or external-external(4)) and the Local Framing Mode to slotted. When you are using an IM1/K and a 1095 standalone at the remote site, the system administrator should set the Clock Mode to external-external(4) and the Remote Framing Mode to slotted.
Illegal configuration messages If you are receiving an invalid configuration indication after creating a configuration, it is resulting from an illegal combination of variables. In most cases, the cause of the problem has to do with the Framing Mode vari- able. Patton DSL modems should only be set to the slotted mode when you are using an IM2RC/K with the 1095RC or an IM1/K with the 1095 standalone unit. Also, if you are using a IM2RC/K or IM1/K interface card, the 1095/1095RC must always be set to the external clock mode. Review the table below for a list of valid configurations that can be used with the 1095/1095RC.
Local Clock Mode Local Framing Mode Remote Clock Mode Remote Framing Mode
Internal Normal Receive Recover Normal External Normal Receive Recover Normal
Externala Slotted Receive Recover Normal
Externala Slotted Externala
Slotted Receive Recover Normal Internal Normal Receive Recover Normal External Normal
a. Denotes a unit that must have an IM2RC/K or IM1/K installed.
System Config 264

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Procedure for creating a template
Figure 130. Global Configuration Menu page
Do the following to create a template:
The Model 1095 Global Configuration window displays (see figure 131).
Figure 131. Model 1095 Global Configuration page
System Config 265

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
– rate64k(3) – rate640k(12) – rate1280k(22) – rate1856k(32)
– rate128k(4) – rate704k(13) – rate1344k(23) – rate1920k(33)
– rate192k(5) – rate768k(14) – rate1408k(24) – rate1984k(34)
– rate256k(6) – rate832k(15) – rate1472k(25) – rate2048k(35)
– rate320k(7) – rate896k(16) – rate1536k(26) – rate2112k(36)
– rate384k(8) – rate960k(17) – rate1600k(28) – rate2176k(37)
– rate448k(9) – rate1024k(18) – rate1664k(29) – rate2240k(38)
– rate512k(10) – rate1088k(19) – rate1728k(30) – rate2304k(39)
– rate576k(11) – rate1216k(21) – rate1792k(31)

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Refer to section “Applying a template” on page 271 to activate the template.
Modifying a template This section describes how to modify a global configuration template. The Patton Model 1095 enables the Model 1001MC system administrator to configure the units for a wide variety of applications. Due to the many different applications that are supported, care must be taken when setting the configuration of your modems. There are several illegal combinations of variables that could cause problems with the modems if implemented incorrectly. Be sure to read the following information before creating a template:
After reviewing the rules and notes, go to section “Procedure for modifying a template” on page 269 to learn how to modify a template.
Configuration rules Keep in mind the following when modifying a template:

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
the unit, so it is not necessary to have a G.703/G.704 link available. When using any other type of serial inter- face, make sure that an external clock is provided by the DTE equipment or the modems will not link.
There are special situations which would require the use of the external-external(4) clock mode setting. This setting should only be used when the application has an IM2RC/K and a 1095RC in the rack system and a IM1/K and a 1095 standalone at the remote site. If you are using any other interface cards do not use the exter- nal-external(4) configuration.
Notes on framing mode settings The Framing Mode Setting notifies the card of the type of interface it will be connected to. When you are using an IM2RC/K with a 1095RC rack card, the system administrator should set the Local Clock Mode to external (either external-receiveRecover(1) or external-external(4)) and the Local Framing Mode to slotted. When you are using an IM1/K and a 1095 standalone at the remote site, the system administrator should set the Clock Mode to external-external(4) and the Remote Framing Mode to slotted.
Illegal configuration messages If you are receiving an invalid configuration indication after creating a configuration, it is resulting from an illegal combination of variables. In most cases, the cause of the problem has to do with the Framing Mode vari- able. Patton DSL modems should only be set to the slotted mode when you are using an IM2RC/K with the 1095RC or an IM1/K with the 1095 standalone unit. Also, if you are using a IM2RC/K or IM1/K interface card, the 1095/1095RC must always be set to the external clock mode. Review the table below for a list of valid configurations that can be used with the 1095/1095RC.
Local Clock Mode Local Framing Mode Remote Clock Mode Remote Framing Mode
Internal Normal Receive Recover Normal External Normal Receive Recover Normal
Externala Slotted Receive Recover Normal
Externala Slotted Externala
Slotted Receive Recover Normal Internal Normal Receive Recover Normal External Normal
a. Denotes a unit that must have an IM2RC/K or IM1/K installed.
System Config 268

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Procedure for modifying a template
Figure 132. Global Configuration Menu page
Do the following to modify a template:
The Model 1095 Global Configuration window displays (see figure 131).
Figure 133. Model 1095 Global Configuration page
System Config 269

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
– rate64k(3) – rate640k(12) – rate1280k(22) – rate1856k(32)
– rate128k(4) – rate704k(13) – rate1344k(23) – rate1920k(33)
– rate192k(5) – rate768k(14) – rate1408k(24) – rate1984k(34)
– rate256k(6) – rate832k(15) – rate1472k(25) – rate2048k(35)
– rate320k(7) – rate896k(16) – rate1536k(26) – rate2112k(36)
– rate384k(8) – rate960k(17) – rate1600k(28) – rate2176k(37)
– rate448k(9) – rate1024k(18) – rate1664k(29) – rate2240k(38)
– rate512k(10) – rate1088k(19) – rate1728k(30) – rate2304k(39)
– rate576k(11) – rate1216k(21) – rate1792k(31)

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Refer to section “Applying a template” on page 271 to activate the template.
Figure 134. Global Configuration Menu page
Deleting a template Do the following to delete a template:
Applying a template This section describes how to apply a global configuration to all Model 1095RC rack cards other than those that meet one of the following exceptions:

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Select the appropriate option from following configuration choices:
Configure all Model 1095RC rack cards in all Model 1001 racks Do the following to apply global configuration to all Model 1095RC rack cards in all Model 1001 racks:
Figure 135. System Level Information page
System Config 272

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference

Figure 136. Web page navigation to System Level Information page
The template has been applied.
System Config 273

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
Configure all Model 1095RC rack cards in one Model 1001 rack Do the following to apply global configuration to all Model 1095RC rack cards installed in one Model 1001 rack:

Figure 137. System Level Information page
The template has been applied.
System Config 274

Model 1001MC Operations Guide 10 • HTTP/HTML web page reference
The Help Menu page (see figure 138) provides hyperlinks to help pages located within the 1001MC. Applica- tions notes are also available on the Model 1001MC CD-ROM or by contacting Patton Electronics Technical Support.

Figure 138. Global Configuration Menu page
The following hyperlinks are available:
Help 275


Model 1001MC Operations Guide 11 • Troubleshooting and maintenance
This chapter describes troubleshooting and fault analysis that can be performed by the operator. This section contains the following sections to help you troubleshoot the 1001MC rack card and NetLink rack cards:
If you require more help, refer to chapter 12, “Contacting Patton for assistance” on page 286.
Refer to table 15 for 1001MC LED locations and definitions, then refer to table 16 on page 278 for a list of common symptoms and suggested remedies.
Table 15. LED indicators

Power Green Power status On = Power is ON Off = Power is OFF LI Green Ethernet: Twisted- pair link indication
On = Connected to active LAN Off = Not connected to active LAN TD Yellow/
Yellow = Idle condition Green = Toggles yellow/green with activity RD Yellow/
Yellow = Idle condition Green = Toggles yellow/green with activity
Toggles when packet TX is on the backplane bus Fault Red Fault condition On = Signals hardware fault Off = No hardware fault
Introduction 277

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance
Table 16. Symptoms and remedies
Power LED (green) is not lit
Fault LED (red) is lit The 1001MC has detected a hardware fault, do the following: TBD.
LI LED (green) is not lit A valid Ethernet link has not been detected, do the following: TBD.
Using the Model 1001MC to troubleshoot a network problem generally involves the following steps:
If you require more help, refer to chapter 12, “Contacting Patton for assistance” on page 286.
Checking 1001MC web pages for warnings or errors Do the following:
– Home page (see figure 139 on page 279)
– About 1001MC page (see figure 140 on page 279)
– System Level Information page (see figure 141 on page 280)
2. If no warnings or errors are listed, check rack card front-panel LEDs to see if one is displaying a fault con- dition (refer to the user manual that came with each rack card for information on using front-panel LEDs to troubleshoot problems). Otherwise, (if you are not already at the System Level Information page) go to the HOME page and click on the Configure Cards link to display the System Level Information page. Look at the Top Level rack information for each rack to see if any are also showing warnings or errors (see figure 141 on page 280).
Troubleshooting network malfunctions 278
Problem Corrective Action

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance
3. If no Top Level racks are showing warnings or errors, go to section “Using the System Log to check for net- work problems” on page 282 to review the System Log: Non-Volatile Memory page for information on what may have caused the problem. Otherwise, click on the View Rack X link (where X is the number of the rack showing warnings or errors, in the example shown in figure 141 on page 280, you would click on View Rack 1).

Figure 139. Home page displaying warnings and errors

Figure 140. About 1001MC page displaying warnings and errors
Troubleshooting network malfunctions 279

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance

Figure 141. System Level Information page displaying warnings and errors
Troubleshooting network malfunctions 280

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance

Figure 142. Modem Information Rack page displaying errors
Troubleshooting network malfunctions 281

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance
Using the System Log to check for network problems The System Log (see figure 143) is a messaging system that stores information about the system as it is running. Do the following to display the System Log: Non-Volatile Memory page for help in troubleshooting a problem:

If you are able to determine the cause of the problem by using the System Log, apply appropriate remedies to resolve the situation. (If the remedy includes replacing a NetLink modem, refer to the user manual that came with the rack card for the procedure on replacing the defective rack card.)
Otherwise, check rack card LEDs in the malfunctioning rack to see if one is displaying a fault condition (refer to the user manual that came with each rack card for information on using front-panel LEDs to troubleshoot problems).
If you are still unable to determine the source of the problem, refer to section “1001MC test mode diagnostics” for information on performing diagnostics tests to isolate the problem.
The Model 1001MC provides the following diagnostics tests and loops that are very helpful when troubleshoot- ing NetLink modems connections:
1001MC test mode diagnostics 282

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance
bits match the agreed aupon pseudo-random pattern, then the NetLink modems and the communication link are functioning properly.

Figure 144. Local loopback diagram

Figure 145. Remote loopback diagram
1001MC test mode diagnostics 283

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance
Table 17. Model 1001MC test mode diagnostics supported by NetLink modem rack cards
five11 five11er lal lalWith511 lalWith511er rdl rdlWith511 rdlWith511er
1092ARC ✔ 1094ARC ✔ 1095RC ✔ 2701RC ✔ 2707RC ✔
Running test mode diagnotics Test mode diagnostics can be performed as follows:
Periodic maintenance Consult the rack chassis user manual for information on preventative maintenance (such as cleaning the chassis air cooling vents to remove accumulated dust).
Calibration The Model 1001MC requires no calibration.
Replacing the Model 1001MC If you isolate a problem to the Model 1001MC, replace the front and rear cards as follows.
Maintenance 284

Model 1001MC Operations Guide 11 • Troubleshooting and maintenance
The Model 1001MC is operational.
Maintenance 285


Model 1001MC Operations Guide 12 • Contacting Patton for assistance
This chapter contains the following information:
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship- ment. All of our products are backed by a comprehensive warranty program.
Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod- uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work- manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.
Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or elephants may require replacement.
Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.
Introduction 287

Model 1001MC Operations Guide 12 • Contacting Patton for assistance
Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.
RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.
Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.
Warranty Service and Returned Merchandise Authorizations (RMAs) 288
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Power LED (green) is not lit | • Verify that power is being supplied to the Model 1001MC • Verify that at least one chassis power supply module is installed in the 1001 rack chassis and functioning normally • Replace the 1001MC (see section “Replacing the Model 1001MC” on page 284) | p.278 | |
| Fault LED (red) is lit | The 1001MC has detected a hardware fault, do the following: TBD. | p.278 | |
| LI LED (green) is not lit | A valid Ethernet link has not been detected, do the following: TBD. | p.278 |