ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS, YOU MAY USE THE SOFTWARE AND/OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT. BY USING THE PARADYNE PRODUCT YOU SHOW YOUR ACCEPTANCE OF THE TERMS OF THIS LICENSE AGREEMENT.
IN THE EVENT THAT YOU DO NOT AGREE WITH ANY OF THE TERMS OF THIS LICENSE AGREEMENT, PROMPTLY RETURN THE UNUSED PRODUCT IN ITS ORIGINAL PACKAGING AND YOUR SALES RECEIPT OR INVOICE TO THE LOCATION WHERE YOU OBTAINED THE PARADYNE PRODUCT OR THE LOCATION FROM WHICH IT WAS SHIPPED TO YOU, AS APPLICABLE, AND YOU WILL RECEIVE A REFUND OR CREDIT FOR THE PARADYNE PRODUCT PURCHASED BY YOU.
The terms and conditions of this License Agreement (the “Agreement”) will apply to the software and/or firmware (individually or collectively the “Software”) incorporated into the Paradyne product (the “Product”) purchased by you and any derivatives obtained from the Software, including any copy of either. If you have executed a separate written agreement covering the Software supplied to you under this purchase, such separate written agreement shall govern.
Paradyne Corporation (“Paradyne”) grants to you, and you (“Licensee”) agree to accept a personal, non-transferable, non-exclusive, right (without the right to sublicense) to use the Software, solely as it is intended and solely as incorporated in the Product purchased from Paradyne or its authorized distributor or reseller under the following terms and conditions:
a. Any warranty that the Software is error-free, will operate uninterrupted in your operating environment, or is compatible with any equipment or software configurations; and

b. ANY AND ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT.
Some states or other jurisdictions do not allow the exclusion of implied warranties on limitations on how long an implied warranty lasts, so the above limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from one state or jurisdiction to another.
Complete documentation for Paradyne products is available at www.paradyne.com. Select Support → Technical Manuals. Select:
Command Line Interface for 4000E and 12000E BACs, Micro DSLAMs, and Network Extenders User's Guide (Document Number CLI-A2-GB20)
Network Management System User's Guide (Document Number NMS-A2-GB20)
SNMP for 12000/4000 BLCs and Micro DSLAMs User's Guide (Document Number SNMP-A2-GB20)
To order a paper copy of a Paradyne document, or to speak with a sales representative, please call 1-727-530-2000.

HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from damage due to electrostatic discharge (ESD) during normal operation. When performing installation procedures, however, take proper static control precautions to prevent damage to equipment. If you are not sure of the proper static control precautions, contact your nearest sales or service representative.
The following components should be included in your package:
4 – Rubber Pads
2 – Rack Mount Brackets
10 – #6 Phillips Bracket Screws
4 – #10 Phillips Rack Screws
4 – #12 Phillips Rack Screws
1 – DB9 Socket to RJ45 Plug Adapter
If there is visible damage, do not attempt to connect the device. Contact your sales representative.
In choosing a location for the installation of this product:
Select a restricted access area where admittance is limited to trained and authorized service personnel.
Ensure that the internal temperature of a rack containing this equipment will not exceed the maximum recommended ambient temperature of 149° F (65° C).
Place the chassis such that connecting cables will not become a tripping hazard or pull loose from the chassis.
Do not block power supply vents or otherwise restrict airflow when installing this equipment.
Ensure that installation of this equipment in a rack will not cause the rack to become top-heavy or unstable.
Do not overload the electrical branch circuit of the power source for this equipment.
For tabletop use, attach the enclosed rubber feet to the bottom of the chassis.
For rack installation, attach the enclosed rack mount brackets to the sides of the chassis with the screws provided.

An SMD2000-24T does not require installation of an Uplink Interface Module (UIM) for operational purposes. A UIM offers additional upstream network ports to supplement the two T1 uplink ports already provided. You may wish to install a UIM if your network requires an Ethernet uplink connection or if you require an additional E1 or T1 backhaul. The SMD2000-24T supports the following 1-port UIMs only:
UIM-T1
UIM-10/100
C AUTION :
Disconnect all power sources from the SMD2000 before installing a UIM.
To install a UIM:




If a slot cover is removed from Port 1 or Port 2, it must be replaced with a UIM. Do not operate the SMD2000-24T with an open UIM port.



UIM Side View · Standoffs


To install the SMD2000-24T on a table, desk, shelf, or remote cabinet:

Bottom of Chassis

To install the SMD2000-24T in a rack:



Turn your DC power source off until you have completed connection of the SMD2000-24T as described below.
Do not operate your SMD2000-24T without a ground connection.
To connect the SMD2000-24T to power:





The two terminal blocks on the SMD2000-24T are independent feeds. Chassis power is supplied by only one terminal block at a time; the second supply is merely backup. Likewise, the two terminal blocks do not load-share. Each terminal block must be supplied with the adequate amperage to run the chassis.





Be sure to attach the positive lead to the positive terminal and the nagative lead to the negative terminal as indicated on your SMD2000-24T terminal block labels.
Positive (Return) Lead · Negative (Batt) Lead


To connect the SHDSL cable to the SMD2000-24T RJ21 connector:
No configuration is necessary for the SMD2000-24T to operate at default settings. However, if you wish to run subscriber lines at settings other than the SMD2000-24T defaults, configure the subscriber lines prior to connection. Parameter settings may be changed using the Command Line Interface (CLI), Simple Network Management Protocol (SNMP), or the web-based management system. SHDSL Parameter Defaults on page 15 lists the device defaults. Product Documentation Online on page 3 lists the user interface manuals.





A primary feature of the SMD2000-24T is its capability to support multiple loop bonded SHDSL connections. However, it is equally capable of supporting up to 24 single line connections, as well as combinations of both single and loop bonded connections.
Multiple SHDSL ports (consecutive or not) may be connected with a single remote SHDSL modem as long as the remote modem is also loop bonding capable. Refer to Product to Product SDSL Loop Bonding Compatibility, (Document Number COMP-A2-GK42), for a complete list of SDSL loop bonding capable products.

The speed and data passing capability of multiple SHDSL lines, as used for one network connection, is cumulative. For example, loop bonding three SHDSL lines for one network connection nets three times the speed and data passing capability of a single-line SHDSL connection. Additionally, use of multiple SHDSL lines for one connection provides automatic backup should one or more lines in the bonded group experience problems or become disabled.
Upon connection, all ports in a bonded group will automatically default to the configurations of the lowest numbered port of the group. Hence, the lowest numbered port of the group should be configured prior to connection if you intend to run the group with parameter settings other than the defaults.
A single line SHDSL subscriber connection may be established with any standard SHDSL subscriber equipment.
The LK (link) LED for each port connected with a remote modem will flash green to indicate a connection has been established. An ACT LED flashing amber indicates SHDSL activity. Link establishment time between the SMD2000-24T and remote SHDSL modems can vary from one to five minutes depending on the quality, gauge, and length of the copper cable pairs being used.

If any of the cable distances are greater than the configured bandwidth will support, the units may not link up or, if they do achieve link, traffic quality may be affected (for example, packets may be dropped).

To connect the SMD2000-24T to T1 service:
No configuration is necessary for the SMD2000-24T to operate at default settings. However, if you wish to run uplinks at settings other than the SMD2000-24T defaults, configure the uplinks prior to connection. Parameter settings may be changed using the Command Line Interface (CLI), Simple Network Management Protocol (SNMP), or the web-based management system. T1 Uplink Parameter Defaults on page 15 lists the device defaults for the T1 uplinks. Product Documentation Online on page 3 lists the user interface manuals.

Using two T1 lines for one uplink connection nets twice the speed and data passing capability of a single-line T1 connection. Additionally, use of a second T1 line provides automatic backup should one of the lines experience problems or become disabled.
A single line T1 uplink connection may be established between T1 Port 1 or T1 Port 2 and any standard T1 provider equipment.


Table 1. SHDSL Defaults
Parameter Default
Circuit Identification n/a (no default)
IP Range 1 0.0.0.0 – 255.255.255.255
IP Range 2 0.0.0.0 – 0.0.0.0
VLAN Priority 0 (none)
VLAN Range 0 - 0 (off)
Table 2. T1 Defaults
Parameter Default
Frame Type Extended Super Frame (ESF)
Line Attenuation 0 dB
Line Code Bipolar with 8 Zero Substitution (B8ZS)
Speed* n/a (T1 uplink speed is determined via communication with the remote T1 provider equipment to which the SMD2000-24T is connected)
* Speed and timing are non-configurable parameters for the SMD2000-24T T1 uplink ports.

No configuration is necessary for an SMD2000-24T to operate at default settings.
Parameter Default
IP Address 192.168.254.252
Subnet Mask 255.255.255.0
Gateway 0.0.0.0
Inband Management VLAN ID 0 (off)
TFTP (Trivial File Transfer Protocol) on
Management IP Address Filter Range 0.0.0.0 – 255.255.255.255 (all)
Uplink DSLAM Interconnection 1 (neither/off)
Table 4. Username and Password Defaults
Username/Passwords
Access Username*
Password*
read only general Password
* Usernames and passwords are case sensitive.
Community String
Access Community String*
* Community strings are case sensitive.

Configuration backup is inherent in the SMD2000-24T. Default parameters remain in place unless changed using the CLI, web management system, or SNMP.
Parameter configurations are automatically recorded in both Random Access Memory (RAM) and Non-Volatile Random Access Memory (NVRAM).
Data stored only in RAM, such as traffic statistics and link up/down time, will be erased if the SMD2000-24T loses power.
Data stored in NVRAM, such as management and port parameter configurations, will remain intact (even if the SMD2000-24T loses power) unless deliberately cleared or reconfigured.
SMD2000-24T management and port configurations can be uploaded to a local file on your PC or local network via the Trivial File Transfer Protocol (TFTP) GET command. Configuration files can also be downloaded from a local file to an SMD2000-24T with a TFTP PUT command. Refer to your TFTP program’s help for further instructions.
An SMD2000-24T backup file records all management and port configurations.
Item Data Needed for Backup Example
Host Name DSLAM_IP Address (xxx.xxx.xxx.xxx) 193.166.254.98
NVR_BACKUP.BIN.[superuser password] nvr_backup.bin.Password
user preference smd4_backup.bin
Remote Filename · Local Filename

An SMD2000-24T template file records all management and port configurations except IP Address.
Item Data Needed for Backup Example
Host Name DSLAM_IP Address (xxx.xxx.xxx.xxx)
193.166.254.98
NVR_CFG.BIN.[superuser password]
nvr_cfg.bin.Password
user preference smd2000_template.bin
A SHDSL port configuration file records all of one port's configurations except Circuit ID.
Item Data Needed for Backup Example
Host Name DSLAM_IP Address (xxx.xxx.xxx.xxx)
193.166.254.98
NVR_PORTCFG.BIN.[superus er password].[1][port]
nvr_portcfg.bin.Password.[1][4]
user preference shdsl_servicelevel4_template.bin
A previously saved port configuration file can be downloaded to multiple ports on your SMD2000-24T simultaneously by entering the port value [port] as:
A comma separated list:
nvr_portcfg.bin.Password.[1][4,6,8]
A dash indicated range:
nvr_portcfg.bin.Password.[1][6-12]
Or using the keyword "all"
nvr_portcfg.bin.Password.[1][all]

The reset button is a small, unmarked button just to the right of the T1 uplink LEDs on the chassis faceplate. The button is recessed and you need a paper clip, mechanical pencil, or similar tool to press it.

A system reset will clear all statistical data (stored in RAM) and restart the SMD2000-24T. It will not clear NVRAM; management settings and port configurations will remain unchanged.
To perform a system reset, press the Reset Button for one second. The reset takes approximately one minute to complete.
A system clear will erase both RAM and NVRAM and restart the SMD2000-24T, restoring all management and port configurations to their original default settings. To clear the system, press the Reset Button for one second, release, and, within five [5] seconds, press the Reset Button again for one second.
After the first pressing of the Reset Button, the passage of five seconds is indicated by the successive flashing of the SHDSL Link (LK) LEDs for Ports 1-5; if you do not press the Reset Button a second time within the allotted five seconds, the SMD2000-24T will perform a system reset (see System Reset, above), rather than a system clear. The clear takes approximately one minute to complete.

Clearing NVRAM to restore original default settings includes restoring the default IP Address, Subnet Mask and Gateway. Additionally, Inband Management will revert to its original default setting (OFF) and you will be required to establish a direct PC to SMD2000-24T connection for any subsequent configurations. Refer to the
Reset Button

Command Line Interface for 4000E and 12000E BACs, Micro DSLAMs, and Network Extenders User's Guide (Document Number CLI-A2-GB20) or the Network Management System User's Guide (Document Number NMS-A2-GB20) for further information.
For purposes of the following descriptions, a pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid, less constant rate.
State Indication Additional Information
Solid green SMD2000-24T is receiving power
Both power terminals are connected.
SMD2000-24T is receiving power
One of the two power terminals is connected.
No power If the SMD2000-24T is not receiving power, none of the LEDs will be illuminated.
FAN Solid green All four fans are fully functional
Fan failure At least one of the four chassis fans is not functioning properly.
Total fan failure None of the four chassis fans is functioning properly.

State Indication Additional Information
LNK (10/100 Ethernet Manage- ment Link)
100 Mbps management connection is established and active
Traffic is flowing at 100 Mbps.
Solid green 100 Mbps management connection is established
No current traffic flow.
10 Mbps management connection is established and active
Traffic is flowing at 10 Mbps.
10 Mbps management connection is established
No current traffic flow.
No management connection NOTE: The LNK LED pertains only to direct connections between the SMD2000-24T and your PC; it does not pertain to remote network access of the SMD2000-24T.
T1 uplink connection is established and active
The uplink port has received valid data from the remote T1 provider equipment within the last second.
Solid green T1 uplink connection is established
A T1 uplink connection exists and the port may be transmitting but it has not received any data from the remote T1 provider equipment within the last second.
Red Alarm: The T1 uplink's incoming connection has been lost; no data is being received.
If the T1 uplink's outgoing connection has also been lost then the remote T1 provider equipment is in Red Alarm as well.

State Indication Additional Information
T1 uplink connection is operational
An established T1 uplink connection has no alarm indications and is operational UNLESS the T1 LK LED remains unlit as well, in which case the T1 uplink connection is in Red Alarm.
Yellow Alarm: The T1 uplink's outgoing connection has been lost; no data is being transmitted.
The remote T1 provider equipment has lost its incoming connection and is in Red Alarm.
Blue Alarm: An indirect connection has been lost; the T1 uplink port may no longer be receiving data from the remote T1 provider equipment.
The remote T1 provider equipment has lost a connection with an intermediate device and is in Red or Yellow Alarm.
SHDSL connection is established and active
The port has received valid data from the remote SHDSL modem within the last second.
Solid green Problematic SHDSL connection
A connection exists but there is indication of a problem with the SHDSL line.
SHDSL connection is established and active
Traffic is flowing.
Heavy traffic The port is receiving unusually large amounts of data from, and/or transmitting unusually large amounts of data to, the remote SHDSL modem.
No activity A link may exist but no data is being transmitted to the remote SHDSL modem.


Table 11. Ethernet RJ45 Connection
Pin Connection

Table 12. T1 RJ48C Pin Assignments
Pin Function
Pin 1 Rx Ring
Pin 2 Rx Tip
Pin 3 not used
Pin 4 Tx Ring
Pin 5 Tx Tip
Pin 6 not used
Pin 7 not used
Pin 8 not used

To connect the COM port to the DB9 serial port of a PC, use an adapter wired as shown:


Pin 8-Pin Modular Port Direction PC RS232 Serial Port Pin
1 Transmit Data TxD → RxD Receive Data 2
2 Data Set Ready DSR ← RTS Request to Send 7
4 Receive Data RxD ← TxD Transmit Data 3
5 Ground GND ↔ GND Ground 5
6 Data Terminal Ready DTR → CTS Clear to Send 8
Pins not shown are unused.

Specification Criteria
Bandwidth and Distance Capabilities – SHDSL Ports
Default is 272 kbps at up to 20,200 ft (6,157 m)
Maximum distance is up to 24,000 ft (18,000 m) at 144 kbps
Maximum bandwidth is 2320 kbps at up to 11,300 ft (3,444 m)
Bandwidth and Distance Capabilities – T1 Uplinks
Maximum bandwidth is 1,536 kbps with all 24 timeslots
Maximum distance is 5,000 ft (1,524 m)
Interfaces 24 SHDSL ports (1 RJ21 50-pin Telco)
2 fixed RJ48C T1 uplink ports
1 RJ45 10/100BaseT management interface
1 RJ45 RS-232 COM port
2 Uplink Interface Module (UIM) slots supporting 10/100BaseT, E1, and T1
1 amp minimum / 1.6 amp maximum (Actual power draw depends on chassis configuration)
Size 1.75" High x 17" Wide x 14" Deep (4.4 cm High x 43.2 cm Wide x 35.6 cm Deep)
Weight 12.5 lbs (5.73 kg)
CE Marking · Power –48V DC

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation.
If the equipment includes a ferrite choke or chokes, they must be installed as described in the installation instructions.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
This equipment complies with Part 68 of the FCC rules and the requirements adopted by the Administrative Council for Terminal Attachments (ACTA). On the bottom of the network extender is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.
The T1 network connections should be made using a Universal Service Order Code (USOC) type RJ48C jack. The Service Order Code 6.0F should be specified to the telephone company when ordering the T1 line. In addition, the proper Facility Interface Code must be specified to the Telephone Company. The network extender can be configured to support any of the following framing format and line signaling techniques. The network extender's configuration must correspond to the T1 line's parameters.
04DU9-BN 1.544 Mbps superframe format (SF) without line power
04DU9-DN 1.544 Mbps SF and B8ZS without line power
04DU9-1KN 1.544 Mbps ANSI ESF without line power
04DU9-1SN 1.544 Mbps ANSI ESF and B8ZS without line power

A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. See installation instructions for details.
If the network extender causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.
If trouble is experienced with this equipment, please contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
Internet: Visit the Paradyne World Wide Web site at www.paradyne.com (Be sure to register your warranty at www.paradyne.com/warranty)
Telephone: Call our automated system to receive current information by fax or to speak with a company representative.
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340
If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved.
The customer may make no repairs to the equipment.
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.
When the product is marked with the CE mark on the equipment label, a supporting Declaration of Conformity may be downloaded from the Paradyne World Wide Web site at www.paradyne.com. Select Library → Technical Manuals → CE Declarations of Conformity.


This is a Class A product based on the standard of the Voluntary Control Council for interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
Class A ITE

9. In addition, since the equipment is to be used with telecommunications circuits, take the following precautions: — Never install telephone wiring during a lightning storm. — Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. — Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. — Use caution when installing or modifying telephone lines. — Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. — Do not use the telephone to report a gas leak in the vicinity of the leak.
Copyright 2005 Paradyne Corporation. Printed in U.S.A.

Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.)
Telephone: Call our automated system to receive current information by fax or to speak with a company representative.
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340