Contentsp.3About This Guidep.7Purpose and Intended Audiencep.7Document Organizationp.7Product-Related Documentsp.8Conventions Usedp.10Configuration Proceduresp.11Configuration Menup.12Configuration Option Areasp.13Accessing and Displaying Configuration Optionsp.14Changing Configuration Optionsp.15Saving Configuration Optionsp.16Basic Configurationp.17Using the Easy Install Featurep.18Using RIP with FrameSaver SLV CSU/DSUsp.27Entering System Information and Setting the System Clockp.28Setting Up Auto-Configurationp.29Selecting a Frame Relay Discovery Modep.30Automatically Removing a Circuitp.32Configuration Optionsp.33Configuration Option Tablesp.33Configuring the Overall Systemp.35Configuring Frame Relay and LMI for the System (CSU/DSUs)p.35Configuring PPP Optionsp.39Configuring Class of Service Definitionsp.40Code Point Definitionsp.42Configuring Service Level Verification Optionsp.43Configuring General System Optionsp.46Configuring Physical Interfacesp.49Configuring the Network Interfacep.49T1 Network Interfacep.50T3 Network Interfacep.54DDS Network Interfacep.55IDSL Network Interfacep.57SDSL Network Interfacep.58SHDSL Network Interfacep.59Synchronous Network Interfacep.60HSSI Network Interfacep.62Configuring a User Data Port (CSU/DSUs)p.63V.35 Data Port Physical Interfacep.63EIA-530-A/X.21/V.35 Data Port Physical Interfacep.68HSSI Data Port Physical Interfacep.70Configuring the T3 User Port (9520-ILM)p.73Configuring the DSX-1 Interface (9126, 9128)p.74Configuring the ISDN DBM Interface (9126, 9128, 9626)p.76Setting Up ISDN Link Profiles (9126, 9128, 9626)p.80Assigning Time Slots/Cross Connectionsp.82Assigning Time Slots to the Network Interfacep.83Assigning DSX-1 Time Slots to the Network Interfacep.84Assigning a Synchronous Data Port to Network or DSX-1 Time Slotsp.90Clearing Assignmentsp.91Configuring Frame Relay for an Interfacep.92Configuring PPP for an Interfacep.95Manually Configuring DLCI Recordsp.96Configuring Circuit Records for the Network Interfacep.100Configuring ATM for the Network Interfacep.103Configuring PVC Connectionsp.104Configuring the IP Path Listp.108Setting Up Management and Communication Optionsp.109Configuring Node IP Informationp.110Configuring Management PVCsp.114Configuring General SNMP Managementp.120Configuring Telnet and/or FTP Session Supportp.121Configuring SNMP NMS Securityp.124Configuring SNMP Traps and Trap Dial-Outp.125Configuring Ethernet Managementp.131Configuring the Communication Portp.133Configuring the Modem Portp.137Configuring the Criteria for Automatic Backupp.141Feature-Specific Configurationp.143Setting Up an External Modemp.144Setting Up an Internal Modemp.145Setting Up Call Directories for Trap Dial-Outp.145Setting Up to Use the Modem PassThru Featurep.146Setting Up Dial Backupp.147Setting Up the DBM Physical Interfacep.147Setting Up Automatic Backup Configurationp.148Modifying ISDN Link Profilesp.151Restricting Automatic Backup and Configuring Backup Timersp.152Configuring the DBM Interface to Send SNMP Trapsp.153Assigning DLCIs to a Backup Groupp.153PVC Backup Over the Network Interfacep.154Setting Up Back-to-Back Operationp.154Changing Operating Modep.154Indexp.157Numericsp.157Ap.157Bp.157Cp.157Dp.158Ep.159Fp.160Gp.160Hp.160Ip.160Kp.160Lp.160Mp.161Np.161Op.162Pp.162Qp.163Rp.163Sp.163Tp.164Up.164Vp.164Wp.165Xp.165
Page 1 of the Paradyne 9623 user manual — Document No. 9000-A2-GB31-00
Page 1 · click to enlarge
Page 1

FrameSaver ® SLV

Configuration Reference

Document No. 9000-A2-GB31-00

December 2002

Page 2 of the Paradyne 9623 user manual — Patent Notification
Page 2 · click to enlarge
Page 2

Copyright © 2002 Paradyne Corporation. All rights reserved. Printed in U.S.A.

Notice

This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773.

Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.

Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual.

Warranty, Sales, Service, and Training Information

Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:

Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.)

Telephone: Call our automated system to receive current information by fax or to speak with a company representative.

— Within the U.S.A., call 1-800-870-2221

— Outside the U.S.A., call 1-727-530-2340

Document Feedback

We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.

Trademarks

ACCULINK, COMSPHERE, FrameSaver, Hotwire, MVL, NextEDGE, OpenLane, and Performance Wizard are registered trademarks of Paradyne Corporation. GranDSLAM, GrandVIEW, ReachDSL, and TruePut are trademarks of Paradyne Corporation. All other products and services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners.

Patent Notification

FrameSaver products are protected by U.S. Patents: 5,550,700 and 5,654,966. Other patents are pending.

A December 2002 9000-A2-GB31-00

Page 3 of the Paradyne 9623 user manual — Table of Contents
Page 3 · Contents
Contents

Contents

Contentsp.3About This Guidep.7Purpose and Intended Audiencep.7Document Organizationp.7Product-Related Documentsp.8Conventions Usedp.10Configuration Proceduresp.11Configuration Menup.12Configuration Option Areasp.13Accessing and Displaying Configuration Optionsp.14Changing Configuration Optionsp.15Saving Configuration Optionsp.16Basic Configurationp.17Using the Easy Install Featurep.18Using RIP with FrameSaver SLV CSU/DSUsp.27Entering System Information and Setting the System Clockp.28Setting Up Auto-Configurationp.29Selecting a Frame Relay Discovery Modep.30Automatically Removing a Circuitp.32Configuration Optionsp.33Configuration Option Tablesp.33Configuring the Overall Systemp.35Configuring Frame Relay and LMI for the System (CSU/DSUs)p.35Configuring PPP Optionsp.39Configuring Class of Service Definitionsp.40Code Point Definitionsp.42Configuring Service Level Verification Optionsp.43Configuring General System Optionsp.46Configuring Physical Interfacesp.49Configuring the Network Interfacep.49T1 Network Interfacep.50T3 Network Interfacep.54DDS Network Interfacep.55IDSL Network Interfacep.57SDSL Network Interfacep.58SHDSL Network Interfacep.59Synchronous Network Interfacep.60HSSI Network Interfacep.62Configuring a User Data Port (CSU/DSUs)p.63V.35 Data Port Physical Interfacep.63EIA-530-A/X.21/V.35 Data Port Physical Interfacep.68HSSI Data Port Physical Interfacep.70Configuring the T3 User Port (9520-ILM)p.73Configuring the DSX-1 Interface (9126, 9128)p.74Configuring the ISDN DBM Interface (9126, 9128, 9626)p.76Setting Up ISDN Link Profiles (9126, 9128, 9626)p.80Assigning Time Slots/Cross Connectionsp.82Assigning Time Slots to the Network Interfacep.83Assigning DSX-1 Time Slots to the Network Interfacep.84Assigning a Synchronous Data Port to Network or DSX-1 Time Slotsp.90Clearing Assignmentsp.91Configuring Frame Relay for an Interfacep.92Configuring PPP for an Interfacep.95Manually Configuring DLCI Recordsp.96Configuring Circuit Records for the Network Interfacep.100Configuring ATM for the Network Interfacep.103Configuring PVC Connectionsp.104Configuring the IP Path Listp.108Setting Up Management and Communication Optionsp.109Configuring Node IP Informationp.110Configuring Management PVCsp.114Configuring General SNMP Managementp.120Configuring Telnet and/or FTP Session Supportp.121Configuring SNMP NMS Securityp.124Configuring SNMP Traps and Trap Dial-Outp.125Configuring Ethernet Managementp.131Configuring the Communication Portp.133Configuring the Modem Portp.137Configuring the Criteria for Automatic Backupp.141Feature-Specific Configurationp.143Setting Up an External Modemp.144Setting Up an Internal Modemp.145Setting Up Call Directories for Trap Dial-Outp.145Setting Up to Use the Modem PassThru Featurep.146Setting Up Dial Backupp.147Setting Up the DBM Physical Interfacep.147Setting Up Automatic Backup Configurationp.148Modifying ISDN Link Profilesp.151Restricting Automatic Backup and Configuring Backup Timersp.152Configuring the DBM Interface to Send SNMP Trapsp.153Assigning DLCIs to a Backup Groupp.153PVC Backup Over the Network Interfacep.154Setting Up Back-to-Back Operationp.154Changing Operating Modep.154Indexp.157Numericsp.157Ap.157Bp.157Cp.157Dp.158Ep.159Fp.160Gp.160Hp.160Ip.160Kp.160Lp.160Mp.161Np.161Op.162Pp.162Qp.163Rp.163Sp.163Tp.164Up.164Vp.164Wp.165Xp.165
Page 7 of the Paradyne 9623 user manual — Document Organization
Page 7 · click to enlarge
Page 7

About This Guide

Purpose and Intended Audience

This document lists and describes the configuration options of the following FrameSaver SLV CSU/DSUs and routers running firmware release 2.1 or above: 9123, 9126, 9128 standalone, 9128 carrier-mount, 9520, 9520-ILM, 9623, 9626, 9720, 9783, 9788, 9820-2M, 9820-8M, and 9820-45M.

Features introduced in firmware release 2.1 are described in this manual but may not be available in all models.

Document Organization

SectionDescription Chapter 1, Configuration ProceduresShows how to access and save configuration options. Chapter 2, Basic ConfigurationDescribes the Easy Install screens, how to set up RIP, and using Auto-Configuration. Chapter 3, Configuration OptionsDescribes configuration options for CSU/DSUs and routers. Chapter 4, Feature-Specific ConfigurationProvides procedures for setting up internal and external modems, Data Backup Modules (DBMs), and back-to-back operation. IndexLists key terms, acronyms, concepts, and sections.

A master glossary of terms and acronyms used in Paradyne documents is available on the World Wide Web at www.paradyne.com. Select Support → Technical Manuals →Technical Glossary.

9000-A2-GB31-00 December 2002 v

Page 8 of the Paradyne 9623 user manual — Product-Related Documents
Page 8 · click to enlarge
Page 8

Product-Related Documents

Complete Paradyne documentation for this product is available at www.paradyne.com. Select Support →Technical Manuals →FrameSaver Frame Relay Devices.

Document NumberDocument Title The FrameSaver SLV reference library contains: 9000-A2-GB30FrameSaver SLV Technical Description Describes the features, interfaces, and cables for FrameSaver SLV CSU/DSUs and routers. 9000-A2-GB31FrameSaver SLV Configuration Reference Lists and describes the configuration options available for FrameSaver SLV CSU/DSUs and routers. 9000-A2-GB32FrameSaver SLV SNMP Reference Describes MIB details, SNMP traps, and RMON data collection used for FrameSaver SLV CSU/DSUs and routers. 9000-A2-GB33FrameSaver SLV Operations Guide Explains how to operate and troubleshoot FrameSaver SLV CSU/DSUs and routers. 9000-A2-GB34FrameSaver SLV Router Command Line Interface Describes special configuration procedures and the command line interface for FrameSaver SLV routers. Other FrameSaver model-specific documentation includes: 9000-A2-GN19FrameSaver SLV ISDN Installation Instructions 9000-A2-GN1D9000 Series Access Carrier Installation Instructions 9123-A2-GN10FrameSaver FLEX 9123 Installation Instructions 9126-A2-GN11FrameSaver SLV 9126 1-Slot Unit Installation Instructions 9126-A2-GN12FrameSaver SLV 9126 Router Installation Instructions 9128-A2-GN10FrameSaver SLV 9128 1-Slot Housing-to-9000 Series Access Carrier Upgrade Instructions 9128-A2-GN11FrameSaver SLV 9128 Network Access Module (NAM) Installation Instructions 9128-A2-GN12FrameSaver SLV 9128 1-Slot Unit Installation Instruction 9520-A2-GN10FrameSaver SLV 9520 Installation Instructions 9520-A2-GN11FrameSaver SLV 9520-ILM Installation Instructions 9623-A2-GN10FrameSaver FLEX 9623 Installation Instruction 9626-A2-GN10FrameSaver SLV 9626 Installation Instructions 9783-A2-GN10Framesaver DSL 9783 CSU/DSU Installation Instructions

vi December 2002 9000-A2-GB31-00

About This Guide

Page 9 of the Paradyne 9623 user manual — Product-Related Documents
Page 9 · click to enlarge
Page 9
Document NumberDocument Title 9783-A2-GN11FrameSaver DSL 9783 Router Installation Instructions 9788-A2-GN10Framesaver DSL 9788 CSU/DSU Installation Instructions 9788-A2-GN11Framesaver DSL 9788 Router Installation Instructions 9820-A2-GN10FrameSaver SLV, Models 9820-2M and 9820-8M, Installation Instructions 9820-A2-GN11FrameSaver SLV, Model 9820-45M, Installation Instructions

To order a paper copy of this or any of the above documents:

Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)

Outside the U.S.A., call 1-727-530-8623

9000-A2-GB31-00 December 2002 vii

About This Guide

Page 10 of the Paradyne 9623 user manual — Conventions Used
Page 10 · click to enlarge
Page 10

Conventions Used

Convention UsedWhen Used ItalicTo indicate variable information (for example, DLCI nnnn, where nnnn denotes a 4-digit number). Menu sequence:To provide an abbreviated method for indicating the selections to be made from a menu or selections from within a menu before performing a procedural step. For example, Main Menu →Status →System and Test Status indicates that you should select Status from the Main Menu, then select System and Test Status. (Path:)To provide a check point that coincides with the menu path shown at the top of the screen. Always shown within parentheses so you can verify that you are referencing the correct table (e.g., Path: main/config/alarm). Brackets [ ]To indicate multiple selection choices when more than one selection is available (e.g., Performance Statistics→Status→[Network/Port-1]). Text highlighted in blueTo indicate a hyperlink to additional information when viewing this manual online. Click on the highlighted text.

viii December 2002 9000-A2-GB31-00

About This Guide

Page 11 of the Paradyne 9623 user manual — Configuration Procedures
Page 11 · click to enlarge
Page 11

Configuration Procedures

This chapter includes the following:

Configuration Option Areas

Accessing and Displaying Configuration Options

Changing Configuration Options

Saving Configuration Options

Configuration Menu

Page 12 of the Paradyne 9623 user manual — CONFIGURATION EDIT/DISPLAY
Page 12 · click to enlarge
Page 12
1. Configuration Procedures

Configuration Menu

Configuration option settings determine how the FrameSaver unit operates. Use the FrameSaver unit’s Configuration Edit/Display menu to display or change configuration option settings.

Configuration options available depend on the model and its features. The Configuration Edit/Display menu shown below is for a FrameSaver SLV 9128 with the optional ISDN backup feature.

Configuration Menu Example

main/config 9128-II Device NameNode A 11/01/2002 09:32

CONFIGURATION EDIT/DISPLAY

System Network DSX-1 Data Ports ISDN Time Slot Assignment PVC Connections Management and Communication Auto Backup Criteria

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Changing an Auto-Configuration setting can also change the FrameSaver unit’s configuration. See Setting Up Auto-Configuration in Chapter 2, Basic Configuration, for additional information.

Save

Page 13 of the Paradyne 9623 user manual — Configuration Option Area Description
Page 13 · click to enlarge
Page 13
1. Configuration Procedures

Configuration Option Areas

The FrameSaver unit arrives with configured factory default settings, which are located in the Factory Default Configuration option area. You can find the default settings for configuration options in the Configuration Option Tables in Chapter 3, Configuration Options.

If the factory default settings do not support your network’s configuration, you can customize the configuration options to better suit your application.

Four configuration option storage areas are available.

Configuration Option Area Description

Current Configuration The currently active set of configuration options.

Customer Configuration An alternate set of configuration options that you can set up and store for future use.

Scratchpad Configuration An alternate configuration area for temporary use. The Scratchpad configuration is reset to the factory default settings when the unit is powered off and on.

Default Factory Configuration A read-only configuration area containing the factory default set of configuration options.

You can load and edit default factory configuration settings, but you can save changes only to the Current, Customer, or Scratchpad configuration option areas.

Page 14 of the Paradyne 9623 user manual — NOTE:
Page 14 · click to enlarge
Page 14
1. Configuration Procedures

Accessing and Displaying Configuration Options

To access and display configuration options, load (copy) the applicable configuration option set into the edit area.

Procedure

To load a set of configuration options for editing:

1. From the Main Menu, press the down arrow key so the cursor is on Configuration.
2. Press Enter to display the Configuration menu. The Load Configuration From: menu appears.

NOTE:

Loading a configuration with many DLCIs from a unit’s Customer or Scratchpad configuration option area may take time. Allow a minute or more for the file to be loaded.

3. Select the configuration option area from which you want to load configuration options and press Enter (Current Configuration, Customer Configuration, Scratchpad Configuration, or Default Factory Configuration).

The selected set of configuration options is loaded into the configuration edit area and the Configuration Edit/Display menu appears.

This sequence of steps would be shown as the menu selection sequence:

Main Menu→Configuration

Page 15 of the Paradyne 9623 user manual — NOTES:
Page 15 · click to enlarge
Page 15
1. Configuration Procedures

Changing Configuration Options

Procedure

To change configuration option settings:

1. From the Configuration Edit/Display menu, select a set of configuration options and press Enter.
For exampleConfiguration → PVC Connections
2. Select the configuration options that are applicable to your network, and make appropriate changes to the setting(s). See the FrameSaver SLV Operations Guide for additional information.

When creating new PVC connections or management PVCs, some configuration options will be blank. For a valid setting to appear, Tab to the configuration option and press the spacebar.

3. Repeat Steps 1 and 2 until all changes are complete.

NOTES:

— Only Security Access Level 1 users can change configuration options.

— Security Access Level 2 users can only view configuration options and run tests.

— Security Access Level 3 users can only view configuration options; they cannot change configuration options or run tests.

Page 16 of the Paradyne 9623 user manual — NOTE:
Page 16 · click to enlarge
Page 16
1. Configuration Procedures

Saving Configuration Options

When changes to the configuration options are complete, use the Save function key to save your changes to either the Current, Customer, or Scratchpad configuration areas. Note that the Scratchpad configuration is reset to the factory default settings when the unit is powered off and on.

Procedure

To save the configuration option changes:

1. Press Ctrl-a to switch to the function key area at the bottom of the screen.
2. Type s or S to select the Save function and press Enter.

The Save Configuration To: screen appears.

NOTE:

If you try to exit the Configuration menu without saving changes, a Save Configuration screen appears requiring a Yes or No response.

— If you select No, the Main Menu screen reappears and the changes are not saved.

— If you select Yes, the Save Configuration To: screen appears.

3. Select the configuration option area to which you want to save your changes (normally the Current Configuration) and press Enter.

When Save is complete, Command Complete appears in the message area at the bottom of the screen.

NOTE:

There are other methods of changing configurations, like SNMP and Auto-Configuration. Since multiple sessions can be active at the same time, the last change made overwrites any previous or current changes being made. For instance:

— Saving your configuration changes would cause configuration changes made via another method to be lost.

— If you are making changes and someone else makes changes and saves them, your changes would be lost.

Page 17 of the Paradyne 9623 user manual — Basic Configuration
Page 17 · click to enlarge
Page 17

Basic Configuration

This chapter includes the following:

Using the Easy Install Feature on page 2-2

Using RIP with FrameSaver SLV CSU/DSUs on page 2-11

Entering System Information and Setting the System Clock on page 2-12

Setting Up Auto-Configuration on page 2-13

— Selecting a Frame Relay Discovery Mode

— Automatically Removing a Circuit

Page 18 of the Paradyne 9623 user manual — Easy Install Screen Example – T3 Interface
Page 18 · click to enlarge
Page 18
2. Basic Configuration

Using the Easy Install Feature

The Easy Install feature provides a straightforward installation menu that requires minimal configuration to get the FrameSaver unit up and running quickly, and to set up remote configuration and management via Telnet access from the NOC (Network Operations Center).

Main Menu→Easy Install

Easy Install Screen Example – T1 Interface

main/easy_install 9126 Device NameNode A 11/01/2002 02:01 EASY INSTALL
Service TypeFrame Relay

Node IP Address: 000.000.000.000 Clear Node Subnet Mask: 000.000.000.000 Clear TS Access: DLCI 980 Create a Dedicated Network Management Link Ethernet Management Options Screen Time Slot Assignment Screen

Network 1 Line Framing Format: ESF Network 1 Line Build Out (LBO): 0.0 Network 1 Line Coding Format: B8ZS DS0 Base rate (Kbps) Nx64

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Easy Install Screen Example – T3 Interface

main/easy_install 9520-ILM Device NameWasau 11/01/2002 12:01 EASY INSTALL
Node IP Address010.102.070.014 Clear Node Subnet Mask: 255.255.255.000 Clear TS Access: None

Create a Dedicated Network Management Link Ethernet Port Options Screen

Network 1 Line Build Out(LBO)Short Port 1 Line Build Out(LBO): Short

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

Save

Page 19 of the Paradyne 9623 user manual — EASY INSTALL
Page 19 · click to enlarge
Page 19
2. Basic Configuration

Easy Install Screen Example – DDS Interface

main/easy_install 9623-SLV Device NameNode A 11/01/2002 02:03 EASY INSTALL

Service Type: Frame Relay Node IP Address: 000.000.000.000 Clear Node Subnet Mask: 000.000.000.000 Clear TS Access: DLCI 980

Create a Dedicated Network Management Link Ethernet Port Options Screen

Transmit Timing: Receive DDS Line Rate (Kbps): Initialize From Network Network Initiated DCLM: V.54 & ANSI DSU Latching Loopback (64KCC): Enable Require DSU Latching Loopback Preamble: Enable

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

Easy Install Screen Example – DSL Interface

main/easy_install 9783 Device NameNode A 09/06/2002 04:02

EASY INSTALL

DSLAM TypeParadyne
Node IP Address000.000.000.000 Clear Node Subnet Mask: 000.000.000.000 Clear TS Access: VPI,VCI 0 , 35

Create a Dedicated Network Management Link Ethernet Management Options Screen

Network 1 DSL Line Rate (Kbps) AutoRate Network 1 FRF.8 Encapsulation Mode Transparent

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

To remotely access the FrameSaver unit in Frame Relay mode, use the Dedicated Network Management Link that was created during installation, using the Node IP Address that was entered for the unit.

See the installation instructions shipped with your unit for additional information and installation procedures.

Save

Page 20 of the Paradyne 9623 user manual — Table 2-1. Easy Install Configuration Options (1 of 7)
Page 20 · click to enlarge
Page 20
2. Basic Configuration

The menu structure and selections, and the features and functions of the FrameSaver unit, are changed based upon the type of service being used.

Table 2-1, Easy Install Configuration Options, describes the entries on the Easy Install screens.

Table 2-1. Easy Install Configuration Options (1 of 7)

Possible SettingsFrame Relay, Leased Line, PPP Default Setting: [Depends on model]

Specifies the type of service to which the unit is to be connected.

Frame Relay – Frame Relay-aware mode, for connection to a frame relay service. This is the default operational mode, and it is used to configure the FrameSaver unit in frame relay mode so that frame relay parameters and SLV functionality can be set up.

If a 9123 unit is set to Leased Line, then changed to Frame Relay, Time Slot Discovery is temporarily suspended until LMI communication is reestablished, and all frame relay-related configuration options previously set up are restored, except for the Sync Data Port Assignments. In this case, all port assignments set to S1Port-1 are converted to FrameRly1 assignments on the Frame Relay Network 1 Assignment timeslot assignment screen.

Leased Line – Leased-line mode, for connection to a standard leased-line service. This mode provides a simple and straightforward screen to guide the installer during initial installation, and to set up remote access to the unit.

When operating in leased-line mode, no frame relay-related statuses, performance statistics, tests, configuration options, or control features are available; only physical layer functions are available.

If the unit is set to Frame Relay then changed to Leased Line, all frame relay-related screens and features are filtered so they are transparent to the user. All frame relay links, DLCIs. and PVCs are preserved. For 9123 units, all Frame Relay Network 1 FrameRly1 time slot assignments are converted to S1Port-1 on the Sync Data Port Assignments screen.

PPP – Point-to-Point Protocol mode. A single PPP circuit exists between Port1 and Net1.

Changing to or from PPP mode causes a reset.

Service Type

Page 21 of the Paradyne 9623 user manual — NOTES:
Page 21 · click to enlarge
Page 21
2. Basic Configuration

Table 2-1. Easy Install Configuration Options (2 of 7)

Possible SettingsParadyne, Alcatel (NewBridge), PairGain, Nokia Default Setting: Paradyne

Ensures interoperability with non-Paradyne DSLAMs, not just the Hotwire GranDSLAM. This option is only available from the Easy Install screen.

NOTES:

– The default is set before the unit is shipped, based upon the CLEC customer

ordering the unit. If you change the default, you must Save the change for it to take effect, which will reset the unit. – When the default is changed, the default settings for other configuration options

change.

Paradyne – The FrameSaver device is used with a Hotwire GranDSLAM.

Alcatel (NewBridge) – The FrameSaver device is used with Alcatel’s NewBridge DSLAM.

PairGain – The FrameSaver device is used with PairGain’s DSLAM.

Nokia – The FrameSaver device is used with Nokia’s DSLAM.

Possible Settings001.000.000.000–126.255.255.255, 128.000.000.000–223.255.255.255, Clear Default Setting: Clear (000.000.000.000)

Specifies the IP address needed to access the node. Since an IP address is not bound to a particular port, it can be used for remote access via a management PVC.

001.000.000.000 – 223.255.255.255 – Shows the IP address for the node, which can be viewed or edited. The first octet of the address cannot be decimal 0 or 127, or greater than 223.

Clear – Fills the node IP address with zeros.

Possible Settings000.000.000.000 – 255.255.255.255, Clear Default Setting: 000.000.000.000

Specifies the IP address subnet mask that is needed to access the node. Since the subnet mask is not bound to a particular port, it can be used with the Node IP address for remote access via a management PVC.

000.000.000.000 – 255.255.255.255 – Shows the subnet mask for the node, which can be viewed or edited.

Clear – Fills the node subnet mask with zeros. When the node’s subnet mask is all zeros, the IP protocol creates a default subnet mask based upon the IP address class (Class A: 255.000.000.000, Class B: 255.255.000.000, or Class C: 255.255.255.000).

DSLAM Type (9783) · Node IP Address · Node Subnet Mask

Page 22 of the Paradyne 9623 user manual — Table 2-1. Easy Install Configuration Options (3 of 7)
Page 22 · click to enlarge
Page 22
2. Basic Configuration

Table 2-1. Easy Install Configuration Options (3 of 7)

Possible SettingsNone, DLCI, VPI,VCI, DLCI_on_VPI,VCI Default Setting: [Depends on model]

Specifies the type of Virtual Circuit (VC) by which special troubleshooting (TS) access is provided to service providers.

Display Conditions – This setting does not appear if Service Type is PPP.

None – No special troubleshooting link is defined.

DLCI – (Models whose network interface does not support ATM.) Allows the user to select a frame relay DLCI to be designated for special troubleshooting access.

VPI,VCI – (Models whose network interface supports ATM.) Specifies an ATM VC on a specific ATM VPI,VCI for TS access. It specifies the VPI and VCI on the network interface for service provider troubleshooting. ATM data is presumed to be encapsulated according to RFC 1483. VPI 0,VCI 35 is the default management path between the FrameSaver device and the DSLAM. The VPI and VCI are entered separately.

– VPI range is 0–15. – VCI range is 32–255.

DLCI_on_VPI,VCI – (Models whose network interface supports ATM.) Specifies a frame relay DLCI VC on a specific ATM VPI,VCI for TS access. DLCI range is 16–1007. ATM data is presumed to be encapsulated according to RFC 1490.

Create a Dedicated Network Management Link

Possible Settings16 – 1007 Default Setting: Initially blank

Enter a DLCI number and (for units that support ATM) VPI,VCI for a dedicated network management PVC.

Display Conditions – This setting does not appear if Service Type is PPP.

16. 1007 – Specifies the DLCI number be used.

Ethernet Management Options Screen

For units with an Ethernet port, provides a link to the Ethernet Management Options Screen. Press Enter and the screen appears. After configuring Ethernet options, press the Esc key to return to the Easy Install screen.

Time Slot Assignment Screen (9123, 9126, 9128)

For units with a T1 network interface, provides a link to the timeslot assignment screen appropriate to the Service Type. Press Enter and:

If Service Type is Frame Relay, the Network 1 Frame Relay Assignments screen

appears.

If Service type is Leased Line, the Sync Data Port Assignments screen appears.

After configuring timeslots, press the Esc key to return to the Easy Install screen.

TS Access

Page 23 of the Paradyne 9623 user manual — Table 2-1. Easy Install Configuration Options (4 of 7)
Page 23 · click to enlarge
Page 23
2. Basic Configuration

Table 2-1. Easy Install Configuration Options (4 of 7)

Network 1 Line Framing Format (9123, 9126, 9128)

Possible SettingsD4, ESF Default Setting: ESF

For units with a T1 network interface, specifies the framing format for transmitted and received signals on the T1 network interface.

D4 – Uses D4 framing format.

ESF – Uses Extended Superframe framing format.

Network 1 Line Coding Format (9123, 9126, 9128)

Possible SettingsAMI, B8ZS Default Setting: B8ZS

For units with a T1 network interface, specifies the line coding format for the network interface.

AMI – Uses Alternate Mark Inversion (AMI) line coding format.

B8ZS – Uses Bipolar 8 Zero Substitution (B8ZS) line coding format.

Network 1 Line Build Out (9123, 9126, 9128)

Possible Settings0.0, –7.5, –15, –22.5 Default Setting: 0.0

For units with a T1 network interface, specifies the line build out for the signal transmitted to the network.

0.0, –7.5, –15, –22.5 – Specifies line build out in dB.

Network 1 Line Build Out (9520, 9520-ILM)

Possible SettingsShort, Long Default Setting: Short

For units with a T3 network interface, specifies whether a line equalization filter is activated to simulate a longer cable.

Short – The equalization filter is activated. Use this option for network cables less than 100 feet long.

Long – The equalization filter is not activated. Use this option for network cables 100 feet or longer.

Port 1 Line Build Out (9520-ILM)

Possible SettingsShort, Long Default Setting: Short

For units with a T3 data port interface, specifies whether a line equalization filter is activated to simulate a longer cable.

Short – The equalization filter is activated. Use this option for DTE cables less than 100 feet long.

Long – The equalization filter is not activated. Use this option for DTE cables 100 feet or longer.

Page 24 of the Paradyne 9623 user manual — Table 2-1. Easy Install Configuration Options (5 of 7)
Page 24 · click to enlarge
Page 24
2. Basic Configuration

Table 2-1. Easy Install Configuration Options (5 of 7)

DS0 Base Rate (9123, 9126, 9128)

Possible SettingsNx64 , Nx56 Default Setting: Nx64

Selects the base rate for the DS0s allocated to frame relay on the network interface.

Nx64 – The base rate is 64 Kbps.

Nx56 – The base rate is 56 Kbps.

Network 1 Port Type (9820-2M, 9820-8M)

Possible SettingsE530, V.35, X.21 Default Setting: V.35

Selects the type of port to be used for the network data port.

E530 – The port is configured as an EIA-530-A-compatible DTE. An EIA-530 compatible DCE can be directly connected to the DB25 connector for this port on the rear of the FrameSaver unit.

V.35 – The port is configured as a V.35-compatible DTE. A V.35-compatible DCE can be connected to the DB25 connector for this port using an adapter cable on the rear of the FrameSaver unit.

X.21 – The port is configured as a V.11/X.21-compatible DTE. A V.11/X.21-compatible DCE can be connected to the DB25 connector for this port using an adapter cable on the rear of the FrameSaver unit.

Network 1 DSL Line Rate Mode (9720, 9783, 9788)

Possible SettingsHunt (9783) , AutoRate, Fixed Default Setting: AutoRate

Specifies the mode to be used for rate selection.

Hunt – (9783 only.) The unit attempts to train at rate specified by Network 1 DSL Line Rate. If that fails, the unit attempts to train at the next higher rate, and, if unsuccessful, cycles through all the rates until training is successful or the unit is reset.

AutoRate – The unit automatically detects the line rate from the network interface.

Fixed – The unit uses the line rate specified by Network 1 DSL Line Rate.

Page 25 of the Paradyne 9623 user manual — Table 2-1. Easy Install Configuration Options (6 of 7)
Page 25 · click to enlarge
Page 25
2. Basic Configuration

Table 2-1. Easy Install Configuration Options (6 of 7)

Network 1 DSL Line Rate (9783)

Possible Settings:

– If DSLAM Type is set to Paradyne, or if DSLAM Type is set to Nokia and Network 1

DSL Line Rate Mode is set to Fixed: 144, 192, 208, 256, 272, 384, 400, 512, 528,

768, 784, 1024, 1152, 1168, 1536, 1552, 2320 – If DSLAM Type is set to Alcatel (NewBridge): 208, 400, 784, 1168, 1552, 2320

– If DSLAM Type is set to Nokia and Network 1 DSL Line Rate Mode is set to Hunt:

192, 384, 768, 1152, 1536

– If DSLAM Type is set to PairGain: 144, 192, 208, 256, 272, 384, 400, 512, 528,

768, 784, 1024, 1152, 1168, 1536, 1552, 2320

Default Setting:

– If DSLAM Type is set to Alcatel (NewBridge) and Network 1 DSL Line Rate Mode is

set to Hunt: 208 – If DSLAM Type is set to Nokia and Network 1 DSL Line Rate Mode is set to Hunt:

384. If DSLAM Type is set to PairGain and Network 1 DSL Line Rate Mode set to Fixed:
784. (If DSLAM Type is set to Paradyne, Network 1 DSL Line Rate Mode is set to

AutoRate and Network 1 DSL Line Rate does not appear)

Determines whether the rate on the DSL interface is set to a specific value or automatically detected using the Conexant AutoBaud algorithm.

144. 2320 – Sets the DSL line rate in kbps.

Network 1 DSL Line Rate (9788)

Possible Settings:

– If PSD Mask is Symmetric: 200, 264, 328, 392, 456, 520, 584, 648, 712, 776, 784,

840, 904, 968, 1032, 1096, 1160, 1224, 1288, 1352, 1416, 1480, 1544, 1552, 1608, 1672, 1736, 1800, 1864, 1928, 1992, 2056, 2120, 2184, 2248, 2312 – If PSD Mask is Asymmetric and Region Setting is Annex A: 776, 784, 1544, 1552

– If PSD Mask is Asymmetric and Region Setting is Annex B: 2056, 2312

Default Setting[None]

Determines the rate on the DSL network interface. Valid rates, and the rates presented on the screen, depend on the values of Region Setting and PSD Mask on the Network Physical Interface Options screen. If a change to another configuration option renders the selected DSL Line Rate invalid, the line rate is set to AutoRate.

Display Conditions – Network 1 DSL Line Rate does not appear if Network 1 DSL Line Rate Mode is set to AutoRate.

200. 2312 – The DSL line rate is set to the specified rate in kbps.

Network 1 Operating Rate (9720)

Possible SettingsAutoRate, 64, 128, 144
Default SettingAutoRate

Determines the rate on the IDSL network interface.

AutoRate – The unit automatically detects the line rate from the network interface.

64, 128, 144 – The IDSL line rate is set to the specified rate in kbps.

Page 26 of the Paradyne 9623 user manual — – 9520: HSSI – 9788, 9820-2M, 9820-8M: V.35
Page 26 · click to enlarge
Page 26
2. Basic Configuration

Table 2-1. Easy Install Configuration Options (7 of 7)

Network 1 Channel (9720)

Possible SettingsB1, B2 Default Setting: B1

Specifies the B channel used for data transfer when the line rate is 64 kbps.

Display Conditions – Network 1 Channel appears only when Network 1 Operating Rate is set to 64.

B1 – The B1 channel is used for data transfer.

B2 – The B2 channel is used for data transfer.

Port-1 Port Type (9520, 9788, 9820-2M, 9820-8M)

Possible SettingsE530, V.35, X.21, HSSI Default Setting:

– 9520: HSSI – 9788, 9820-2M, 9820-8M: V.35

Specifies the port type of the data port.

E530 – The port is configured as an EIA-530-A-compatible DCE. An EIA-530-A- compatible DTE may be directly connected to the DB25 connector for the port.

V.35 – The port is configured as a V.35-compatible DCE. A V.35-compatible DTE may be connected to the port using a DB25-to-MS34 adapter.

X.21 – The port is configured as an X.21-compatible DCE. An X.21-compatible DTE may be connected to the port using a DB25-to-DB15 adapter.

HSSI – The port is configured as a HSSI-compatible DCE. A HSSI-compatible DTE may be directly connected to the DB25 connector for the port.

Port 1 Port Rate (9520)

Possible Settings (HSSI)7456, 11184, 17250, 25875, 44736, 51750 Default Setting (HSSI): 51750

Possible Settings (V.35): 512, 1025, 1537, 2050, 2562, 3074, 3587, 4099, 4611, 5124, 5636, 6149, 6661, 7073, 7685, 8197 Default Setting (V.35): 6149

Selects the clock rate in Kbps for the user data port.

Network 1 FRF.8 Encapsulation Mode (9783 and 9788)

Possible SettingsTranslational, Transparent Default Setting: Transparent

Specifies the type of FRF.8 upper-layer protocol encapsulation used on the link for each pair of interoperable Frame Relay and ATM PVCs.

Translational – Encapsulated data is translated (RFC 1490 to RFC 1483). FrameSaver multiplexing and SLV communications are not supported in this mode.

Transparent – Encapsulated data is forwarded without being translated.

Page 27 of the Paradyne 9623 user manual — Procedure
Page 27 · click to enlarge
Page 27
2. Basic Configuration

Using RIP with FrameSaver SLV CSU/DSUs

Using the system’s standard Routing Information Protocol (RIP) feature, routing information is passed to the router over the management PVC, so the router can learn routes to FrameSaver devices. Node IP information should be set up (see Using the Easy Install Feature on page 2-2).

Procedure

To set up your router and FrameSaver SLV CSU/DSU so that the router can learn routes to FrameSaver devices:

1. Configure the router to receive RIP.

For example, if using a Cisco router, you would use the commands config-t, router RIP, int serialx, IP RIP Receive version 1, then ctl-z WR.

2. Create a Standard DLCI for the user data port.

Configuration→Data Ports→DLCI Records

3. Create a Management PVC using the user data port DLCI just configured.

Configuration→Management and Communication→Management PVCs

4. Set Primary Link RIP to Standard_Out, and Save the configuration.

Refer to Table 3-26, DLCI Record Options, and Table 3-32, Management PVC Options, in Chapter 3, Configuration Options, for configuration information.

Page 28 of the Paradyne 9623 user manual — NOTE:
Page 28 · click to enlarge
Page 28
2. Basic Configuration

Entering System Information and Setting the System Clock

Select System Information to set up or display the general SNMP name for the unit, its location, and a contact for the unit, as well as to set the system clock.

Main Menu→Control→System Information

The following information is available for viewing. Save any entries or changes.

If the selection is . . . Enter the . . .

Device Name Unique name for device identification of up to 20 characters.

System Name SNMP system name; can be up to 255 characters.

System Location System’s physical location; can be up to 255 characters.

System Contact Name and how to contact the system person; can be up to 255 characters.

Date Current date in the month/day/year format (mm/dd/yyyy).

Time Current time in the hours:minutes format (hh:mm).

NOTE:

To clear existing information, place the cursor in the Clear field (Tab to the Clear field) and press Enter.

See the FrameSaver SLV Operations Guide to set up and administer logins.

Page 29 of the Paradyne 9623 user manual — AUTO-CONFIGURATION
Page 29 · click to enlarge
Page 29
2. Basic Configuration

Setting Up Auto-Configuration

The auto-configuration feature is available in frame relay mode on all models except those with DSL interfaces. It allows you to select a method of automatic configuration and connection of DLCIs within the FrameSaver unit, as well as to automatically remove DLCIs and connections that are no longer supported by the network service provider.

Main Menu→Auto-Configuration

Auto-Configuration Screen Example

main/auto-configuration 9128-II Device Name: Node A 8/18/2000 23:32

AUTO-CONFIGURATION

Frame Relay Discovery Mode1MPort Automatic Circuit Removal: Enable Automatic Backup Configuration: Single_Site_Backup

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

This feature also maintains associated DLCI option settings when Standard LMI is used on the network interface.

If an ISDN DBM is not installed, Automatic Backup Configuration does not appear (see Setting Up Automatic Backup Configuration in Chapter 4, Feature-Specific Configuration) for additional information).

Save

Page 30 of the Paradyne 9623 user manual — Discovery Mode Configuration Description
Page 30 · click to enlarge
Page 30
2. Basic Configuration

Selecting a Frame Relay Discovery Mode

When a Frame Relay Discovery Mode is active, the FrameSaver unit “discovers” network DLCIs from the network LMI status response message. It configures a network DLCI and a user data port DLCI, and automatically connects them to create a PVC.

Main Menu→Auto-Configuration→Frame Relay Discovery Mode

Automatically configured network DLCIs are multiplexed, and each automatically configured port DLCI carries the same DLCI Number as its corresponding network DLCI. These are the same DLCI numbers that would have been available had the FrameSaver unit not been inserted in the link, between your equipment and the network.

NOTE:

A local Management PVC (e.g., the PVC between the router and the FrameSaver unit’s user data port) must be configured manually.

The following will occur when a Frame Relay Discovery Mode is selected:

Discovery Mode Configuration Description

1MPort Auto-configuration is enabled on Port-1.

A management DLCI is configured.

A multiplexed network DLCI containing two embedded

DLCIs (EDLCIs) is configured for Port-1 user data and management data.

A PVC connection is configured between the network

and port DLCIs.

1Port Auto-configuration is enabled on Port-1.

No management DLCI is configured.

A multiplexed network DLCI is configured for Port-1 user

data.

A PVC connection is configured between the network

and port DLCIs.

1PPort Auto-Configuration is enabled on Port-1.

A Port-1 DLCI is created for each network DLCI and

automatically cross-connected to it.

Payload management is configured for the network

DLCI and assigned the Node IP Address.

Auto-configuration is enabled on both Port-1 and Port-2.

A multiplexed network DLCI containing three EDLCIs is

(only applies to models with multiple data ports)

configured for Port-1 customer data, Port-2 customer data, and management data.

PVC connections are configured between the network

and port DLCIs.

A management PVC is configured on the network

interface.

2MPorts

Page 31 of the Paradyne 9623 user manual — NOTE:
Page 31 · click to enlarge
Page 31
2. Basic Configuration

Discovery Mode Configuration Description

NetOnly Auto-configuration of a network DLCI only; no Port-1 or

PVC connections are configured.

No Port-1, PVC connection, or management DLCI is

configured.

Disable No frame relay discovery or automatic configuration

takes place.

The FrameSaver unit will be configured manually.

NOTE:

If the default setting (1MPort or 1PPort) is not the setting required for your application, change the Frame Relay Discovery Mode before connecting the network cable or editing discovered option settings. Otherwise, the FrameSaver unit will start discovering DLCIs as soon as it powers up.

If this occurs, you can recover by deleting the discovered DLCIs. If only a local management PVC between the router and the FrameSaver unit has been configured, simply select the desired Frame Relay Discovery Mode and Save the change.

The default discovery mode, depending on model, is 1MPort or 1PPort.

When 1MPort mode is active, the unit creates for each DLCI discovered on the network a multiplexed network interface DLCI (which contains two EDLCIs: one for Port-1 data and the other for management), a standard Port-1 DLCI (with the same number as the network interface DLCI), and a Management PVC, then cross-connects them. When LMI is active on the network interface and PVC status information (with provisioned DLCI numbers) is next received from the network, the unit automatically saves the settings to the Current Configuration area.

When 1PPort mode is active, the unit uses the Network DLCI values obtained from the Network LMI status response message to automatically configure for each DLCI a corresponding DLCI for Port 1 having the same numeric value as the Network DLCI, and automatically cross connects them. The DLCIs created on the network side are IP Enabled (not standard or multiplexed) DLCIs. In addition, payload management is configured for the network DLCI and assigned the Node IP Address.

Configuration options set by selecting a discovery mode can be manually modified, refined, or deleted at any time using the Configuration menus. No previously discovered and configured DLCIs or cross-connections will be removed unless authorized or Automatic Circuit Removal is enabled (see Automatically Removing a Circuit on page 2-16). Additional discovered DLCIs will be configured according to the current Frame Relay Discovery Mode setting. Selecting or changing the setting will not affect IP Addresses or Subnet Masks.

NOTE:

When auto-configuration creates a multiplexed DLCI, but a standard DLCI is needed, change the DLCI to standard from the network DLCI Records screen:

Configuration→Network→DLCI Records

Page 32 of the Paradyne 9623 user manual — Automatically Removing a Circuit
Page 32 · click to enlarge
Page 32
2. Basic Configuration

When a Frame Relay Discovery Mode is changed and saved, the Saving will cause Auto-Configuration to update and Restart. Are you sure? prompt appears. No is the default for this prompt.

If Yes (y) is entered, the Delete All DLCIs and PVC Connections? prompt appears. No is the default for this prompt.

— If Yes is entered, all multiplexed DLCIs and PVC Connections are deleted, except for Management PVCs with the user data port as the primary destination and the Management PVC that is designated as TS Management Link.

— If No is entered, previously discovered and auto-configured option settings will not be removed, but configuration updates due to LMI response messages are performed according to the just saved mode setting.

If No (n) is entered, or if you exit the screen without responding to the prompt, no Auto-Configuration updates are performed and updates due to LMI response messages are performed according to the previously saved setting.

Automatically Removing a Circuit

Using the automatic circuit removal feature, which comes enabled, network DLCIs and PVCs can be automatically removed from the unit’s configuration when the network service provider no longer supports them. Automatic deletion is based upon information from a LMI full status response on an active frame relay link.

When this feature is set to:

Enable – The following will be automatically removed from the unit’s configuration:

— Unsupported network DLCIs and PVC connections that include multiplexed network DLCIs.

— Standard network DLCIs that are Payload Managed or IP Enabled.

— Unsupported standard network DLCIs that are not configured as the primary destination in a management PVC.

— Non-management PVCs in which unsupported standard network DLCIs are included.

— DLCIs not included in three consecutive LMI full status response messages.

— LMI status responses that indicate a Deleted status for the DLCI.

All configured options relating to the deleted circuits are also deleted and they revert to their default settings.

A DLCI will not be deleted if the physical interface or frame relay link is down, or if the DLCI is used for the TS Management Link.

Disable – Unused network DLCIs, PVC connections, and management PVCs must be manually removed.

If the model has ISDN backup capability, ISDN Link Profiles associated with the deleted records and alternate destinations will be deleted, as well.

Page 33 of the Paradyne 9623 user manual — Configuration Option Tables
Page 33 · click to enlarge
Page 33

This chapter includes the following:

Configuring the Overall System on page 3-3

Configuring Physical Interfaces on page 3-17

Assigning Time Slots/Cross Connections on page 3-50

Configuring PPP for an Interface on page 3-63

Manually Configuring DLCI Records on page 3-64

Configuring Circuit Records for the Network Interface on page 3-68

Configuring ATM for the Network Interface on page 3-71

Configuring PVC Connections on page 3-72

Configuring the IP Path List on page 3-76

Setting Up Management and Communication Options on page 3-77

Configuring the Criteria for Automatic Backup on page 3-109

Configuration Option Tables

Configuration option descriptions contained in this chapter are in menu order, even though this may not be the order in which you access each when configuring the unit.

The following configuration option tables are included:

Table 3-1, System Frame Relay and LMI Options

Table 3-2, PPP Options

Table 3-3, Class of Service Definitions

Table 3-4, Code Point Definitions

Table 3-5, Service Level Verification Options

Table 3-6, General System Options

Table 3-7, T1 Network Physical Interface Options

Page 34 of the Paradyne 9623 user manual — Configuration Options
Page 34 · click to enlarge
Page 34

Table 3-8, T3 Network Physical Interface Options

Table 3-9, DDS Network Physical Interface Options

Table 3-10, IDSL Network Physical Interface Options

Table 3-11, SDSL Network Physical Interface Options

Table 3-12, SHDSL Network Physical Interface Options

Table 3-13, Synchronous Network Data Port Physical Interface Options

Table 3-14, HSSI Network Data Port Physical Interface Options

Table 3-15, V.35 Data Port Physical Interface Options

Table 3-16, EIA-530-A/X.21/V.35 Data Port Physical Interface Options

Table 3-17, HSSI Data Port Physical Interface Options

Table 3-18, T3 User Port Physical Interface Options

Table 3-19, DSX-1 Physical Interface Options

Table 3-20, ISDN BRI DBM Physical Interface Options (9126, 9626)

Table 3-21, ISDN PRI DBM Physical Interface Options (9128)

Table 3-22, ISDN Link Profile Options

Table 3-23, Signaling and Trunk Conditioning Values

Table 3-24, Interface Frame Relay Options

Table 3-25, Interface PPP Options

Table 3-26, DLCI Record Options

Table 3-27, Circuit Records Options

Table 3-28, Network ATM Options

Table 3-29, PVC Connection Options

Table 3-30, IP Path List

Table 3-31, Node IP Options

Table 3-32, Management PVC Options

Table 3-33, General SNMP Management Options

Table 3-34, Telnet and FTP Session Options

Table 3-35, SNMP NMS Security Options

Table 3-36, SNMP Traps and Trap Dial-Out Options

Table 3-37, Ethernet Management Options

Table 3-38, Communication Port Options

Table 3-39, Modem Port Options

Table 3-40, Auto Backup Criteria Options

Page 35 of the Paradyne 9623 user manual — Table 3-1. System Frame Relay and LMI Options (1 of 4)
Page 35 · click to enlarge
Page 35

Configuring the Overall System

The System menu options are explained in the following sections:

Configuring Frame Relay and LMI for the System (CSU/DSUs)

Configuring PPP Options

Configuring Class of Service Definitions

Configuring Service Level Verification Options

Configuring General System Options

Configuring Frame Relay and LMI for the System (CSU/DSUs)

Select Frame Relay and LMI from the System menu to display or change the Frame Relay and LMI options for the entire system (see Table 3-1, System Frame Relay and LMI Options). The option appears only when Service Type is Frame Relay.

Main Menu→Configuration→System →Frame Relay and LMI

See Configuring PPP for an Interface on page 3-63 to set an interface’s frame relay options.

Table 3-1. System Frame Relay and LMI Options (1 of 4)

Possible Settings: Independent, Net1-FR1_Follows_Port-1, Net1-FR1_Follows_Port-2, Net1-FR1_Follows_Rtr-S0, Port-1_Follows_Net1-FR1, Port-2_Follows_Net1-FR1, Rtr-S0_Follows_Net1-FR1, All_Ports_Follow_Net1-FR1, Port-1_Codependent_with_Net1-FR1, Port-2_Codependent_with_Net1-FR1, Rtr-S0_Codependent_with_Net1-FR1,

Default SettingIndependent

Configures the device to allow the state of the LMI to be passed from one interface to another, determining how the unit will handle a change in the LMI state. Sometimes referred to as LMI pass-through.

Display Conditions – Port-n options are available on CSU/DSUs and Rtr-S0 options are available on FrameSaver SLV Routers. Port-2 options are available on units with two data ports.

Independent – Handles the LMI state of each interface separately so that the LMI state of one interface has no effect on the LMI state of another interface. Provides LMI Spoofing. This is the recommended setting when backup is configured, and for Network Service Providers (NSPs).

LMI Behavior

Page 36 of the Paradyne 9623 user manual — Table 3-1. System Frame Relay and LMI Options (2 of 4)
Page 36 · click to enlarge
Page 36

Table 3-1. System Frame Relay and LMI Options (2 of 4)

Net1-FR1_Follows_Port-1 – Brings LMI down on the network interface when LMI on Port-1 goes down, disabling the network interface and deasserting its control leads. When LMI on Port-1 comes back up, the network interface is reenabled. The LMI state on the network interface has no effect on the LMI state on Port-1. That is, the network interface’s LMI follows Port-1’s LMI. Used at central sites, this setting is useful when the remote site router on the other end of the PVC connection can initiate recovery via a redundant central site when there is a catastrophic central site LAN or router failure. Not recommended for NSPs.

Net1-FR1_Follows_Port-2 – Reacts like the Net1-FR1_Follows_Port-1 selection, but for Port-2 instead.

Rtr-S0_Follows_Port-1 – Brings LMI down on the network interface when LMI on Rtr-S0 goes down, disabling the network interface and deasserting its control leads. When LMI on Rtr-S0 comes back up, the network interface is reenabled. The LMI state on the network interface has no effect on the LMI state on Rtr-S0. That is, the network interface’s LMI follows Rtr-S0’s LMI.

Port-1_Follows_Net1-FR1 – Brings LMI down on Port-1 when LMI on the network interface goes down, disabling Port 1 and deasserting its control leads. When LMI on the network interface comes back up, Port-1 is reenabled and its control leads are reasserted. The LMI state on Port-1 has no effect on the LMI state on the network interface. That is, Port-1’s LMI follows the network interface’s LMI. This setting is useful if the router connected to Port-1 is used to initiate recovery when network failures are detected.

Port-2_Follows_Net1-FR1 – Reacts like the Port-1_Follows_Net1-FR1 selection, but for Port-2 instead.

Rtr-S0_Follows_Net1-FR1 – Brings LMI down on Rtr-S0 when LMI on the network interface goes down, disabling Rtr-S0. When LMI on the network interface comes back up, Rtr-S0 is reenabled. The LMI state on Rtr-S0 has no effect on the LMI state on the network interface. That is, Rtr-S0’s LMI follows the network interface’s LMI.

All_Ports_Follow_Net1-FR1 – Brings LMI down on all user data ports when LMI on the network interface goes down, disabling all ports and deasserting their control leads. Allows LMI to come back up and reenables the ports when LMI comes up on the network. That is, LMI on each port follows the network interface’s LMI. The state of LMI on the port will not affect the state of LMI on the network interface.

Port-1_Codependent_with_Net1-FR1 – Brings LMI down on the network interface when LMI on Port-1 goes down (or LMI down on Port-1 when LMI on the network interface goes down), and allows LMI to come back up when LMI comes back on the other interface. That is, the LMI state for one interface is dependent on the other. Use this setting when backup is through the router instead of the unit. It is not recommended since it makes fault isolation more difficult.

Port-2_Codependent_with_Net1-FR1 – Reacts like the Port-1_Codependent_with_Net1-FR1 selection, but for Port-2 instead. The state of LMI on the network interface will not affect the state of LMI on Port-1.

Rtr-S0_Codependent_with_Net1-FR1 – Brings LMI down on the network interface when LMI on Rtr-S0 goes down (or LMI down on Rtr-S0 when LMI on the network interface goes down), and allows LMI to come back up when LMI comes back on the other interface. That is, the LMI state for one interface is dependent on the other.

LMI Behavior (continued)

Page 37 of the Paradyne 9623 user manual — Table 3-1. System Frame Relay and LMI Options (3 of 4)
Page 37 · click to enlarge
Page 37

Table 3-1. System Frame Relay and LMI Options (3 of 4)

LMI Behavior (9783 and 9788)

Possible SettingsIndependent, Net1-FR1_Follows_Port-1, Port-1_Follows_Net1-FR1, Port-1_Codependent_with_Net1-FR1
Default SettingPort-1_Codependent_with_Net1-FR1

For units that support ATM, configures the state of LMI on Port-1 and the state of the ATM link on the network interface to be passed from one interface to another.

Independent – Handles the state of each interface separately so that the LMI state of Port-1 has no effect on the state of the ATM link on the network interface, and vice versa.

Net1-FR1_Follows_Port-1 – Brings down VCs cross-connected to Port-1 on the network interface when LMI on Port-1 goes down, and sends F5 OAM cells on all network VCs cross-connected to Port-1 DLCIs to alert the network and far-end device that frame relay data can not be delivered through the device. When LMI on Port-1 comes back up, the network VCs are also re-enabled. This setting is useful at a central site when the remote site router on the other end of the PVC connection can initiate recovery via a redundant central site when there is a catastrophic central site LAN or router failure. Not recommended for NSPs.

Port-1_Follows_Net1-FR1 – Brings down LMI on Port-1 when there is a physical failure or ATM failure on the network interface. When the alarm on the network interface is cleared, Port-1 is re-enabled and its control leads are reasserted. This setting is useful if the router connected to Port-1 is used to initiate recovery when network failures are detected.

Port-1_Codependent_with_Net1-FR1 – The LMI state for Port 1 and the Net1-FR1 interface are dependent on each other. If the LMI is down on either interface, the system will bring the LMI down on the other interface. When the LMI is up on either interface, the system will bring the LMI up on the other interface. When Port-1 LMI goes down, in addition to bringing down the internal network frame relay link, the unit also sends F5 OAM cells on all network VCs cross-connected to Port-1 DLCIs to alert the network and far-end device that frame relay data can not be delivered through the device. Use this setting when backup is through the router instead of the unit. Note that when the router is disconnected, the NSP cannot access the unit using multiplexed VCs.

LMI Error Event (N2)

Possible Settings1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Default Setting: 3

Configures the LMI-defined N2 parameter, which sets the number of errors that can occur on the LMI link before an error is reported. Applies to both the user and network sides of a UNI.

1. 10 – Specifies the maximum number of errors.

LMI Clearing Event (N3)

Possible Settings1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Default Setting: 1

Configures the LMI-defined N3 parameter, which sets the number of error-free messages that must be received before clearing an error event. Applies to both the user and network sides of a UNI.

1. 10 – Specifies how many error-free messages it will take to clear the error event.
Page 38 of the Paradyne 9623 user manual — Table 3-1. System Frame Relay and LMI Options (4 of 4)
Page 38 · click to enlarge
Page 38

Table 3-1. System Frame Relay and LMI Options (4 of 4)

LMI Status Enquiry (N1)

Possible Settings1, 2, 3, 4, . . . 255 Default Setting: 6

Configures the LMI-defined N1 parameter, which sets the number of status enquiry polling cycles that the user side of the LMI initiates before a full status enquiry is initiated. Applies to the user side of a UNI only.

1. 255 – Specifies the number of status enquiry polling cycles that can be initiated before a full status enquiry is initiated.
Possible Settings5, 10, 15, 20, 25, 30 Default Setting: 10

Configures the LMI-defined T1 parameter, which sets the number of seconds between the initiation of status enquiry messages on the user side of the LMI. Applies to the user side of a UNI only.

5. 30 – Specifies the number of seconds between the initiation of status enquiry messages in increments of 5.

LMI Inbound Heartbeat (T2)

Possible Settings5, 10, 15, 20, 25, 30 Default Setting: 15

Configures the LMI-defined T2 parameter, which sets the number of seconds between the receipt of status enquiry messages on the network side of the LMI. Applies to the network side of a UNI only.

5. 30 – Specifies the number of seconds between the receipt of status enquiry messages in increments of 5.

LMI N4 Measurement Period (T3)

Possible Settings5, 10, 15, 20, 25, 30 Default Setting: 20

Configures the LMI-defined T3 parameter, which is the time interval (in seconds) that the network side of the LMI uses to measure the maximum number of status enquiry messages that have been received (N4) from the user side.

5. 30 – Specifies the interval of time in increments of 5.

LMI Heartbeat (T1)

Page 39 of the Paradyne 9623 user manual — Table 3-2. PPP Options
Page 39 · click to enlarge
Page 39

Configuring PPP Options

PPP options are selected from the System menu (see Table 3-2, PPP Options). The option appears only when Service Type is PPP.

Main Menu→Configuration→System→PPP

Table 3-2. PPP Options

PPP

Possible SettingsIndependent, Port-1_Follows_Net Default Setting: Independent

Allows you to pass the state of PPP from one interface to the other.

Independent – The state of PPP on one interface does not affect the state of the other.

Port-1_Follows_Net – The state of PPP on Port 1 depends on the state of PPP on the Network 1 interface. If PPP is down on Network 1, the system brings down PPP on the Port 1 interface and disables the port, causing the DSR, CD, and CSR control leads to be deasserted. If PPP is up on Network 1, the system enables Port 1 and asserts the control leads.

Page 40 of the Paradyne 9623 user manual — Field Setting After RfcCodePoints Selected
Page 40 · click to enlarge
Page 40

Configuring Class of Service Definitions

Select Class of Service Definitions from the System menu to display or change the Class of Service definitions to be used with latency, availability, and throughput measurements of IP traffic on IP Enabled circuits.

Main Menu→Configuration→System →Class of Service Definitions

The Class of Service Definitions screen appears.

Procedure

To create a new Class of Service definition:

1. To manually assign definition names and code points, proceed to Step 4
2. To automatically create Class of Service names and associate them with code points according to RFCs 2474, 2497, and 2498, select RfcCodePoints. The following settings are established:

Field Setting After RfcCodePoints Selected

Class of Service Name 1 – NewCtrl 2 – Expd Fwd 3 – AFClass4 4 – AFClass3 5 – AFClass2 6 – AFClass1 7 – Default

Measure Latency & Availability 1 – N 2 – Y 3 – Y 4 – Y 5 – Y 6 – Y 7 – Y

Code Points 1 (NetwCtrl) – 110000, 111000 2 (Expd Fwd) – 101110 3 (AFClass4) – 100010, 100100, 100110 4 (AFClass3) – 011010, 011100, 011110 5 (AFClass2) – 010010, 010100, 010110 6 (AFClass1) – 001010, 001100, 001110 7 (Default) – 000000

3. If these settings are satisfactory, proceed to Step 10 .
4. Type a name of up to 8 characters into one of the Name fields next to IDs 1–6.
5. To unassign all code points by inserting blank names, select ClrAllCodePoints. To assign all Code Points to a Class of Service name of Default, select DefaultCodePoints.
6. Select PgDn or PgUp. The Code Point Assignment screen appears.
7. For any Code Point you want to assign to the name, type the name you selected in Step 4 into the Name field to the right of the Code Point.
Page 41 of the Paradyne 9623 user manual — Table 3-3. Class of Service Definitions
Page 41 · click to enlarge
Page 41
8. Select Save, then select PgDn or PgUp. The Class of Service Definitions page reappears. In the Code Points Assigned column next to your selected name there is now a Y for Yes.
9. If latency and availability should be measured for the selected name, change the N in the Measure Latency & Availability column to Y.
10. Select Save.

To configure these options, Service Type on the Easy Install screen must be set to Frame Relay.

Table 3-3. Class of Service Definitions

Class of Svc Name

Possible SettingsASCII Text Entry Default Setting:
For IDs 2–7blank For ID 1: Default

Specifies a name to identify a Class of Service definition.

ASCII Text Entry – Enter a unique name for the definition (maximum length 8 characters).

Measure Latency & Availability

Possible SettingsN, Y Default Setting:
For IDs 2–7N For ID 1: Y

Determines whether latency and availability are measured for this Class of Service ID.

Display Conditions – This option is set to N and is read-only until the class of service is defined and code points are assigned to it.

N – Latency and availability are not measured for this Class of Service ID.

Y – Latency and availability are measured for this Class of Service ID.

Possible SettingsY, N Default Setting:
For IDs 2–7N For ID 1: Y

This read-only field shows whether a Code Point has been assigned to this Class of Service ID on the Code Point Definitions screen.

N – No Code Point is assigned to this ID.

Y – At least one Code Point is assigned to this ID.

Code Points Assigned

Page 42 of the Paradyne 9623 user manual — ID
Page 42 · click to enlarge
Page 42

Code Point Definitions

Select Class of Service Definitions from the System menu, then PgDn or PgUp, to display or change the Code Point definitions for a Class of Service ID. See Configuring Class of Service Definitions on page 3-8 for instructions.

Table 3-4. Code Point Definitions

Possible Settings: 000000–111111 Default Setting: None.

This read-only field shows the possible Code Points. Code Points are described in RFC 2474.

ID

Possible Settings1–7 Default Setting: 1

This read-only field shows the ID associated with the Name field. If you change a name in a Name field on this screen and select Save, the ID changes to match the name.

Possible SettingsASCII Text Default Setting: Default

The Name field specifies the Class of Service to which you want to assign the Code Point.

ASCII Text – Specifies one of the Class of Service Names entered on the Class of Service Definitions screen.

Code Pnt · Name

Page 43 of the Paradyne 9623 user manual — Table 3-5. Service Level Verification Options (1 of 3)
Page 43 · click to enlarge
Page 43

Configuring Service Level Verification Options

SLV options are selected from the System menu (see Table 3-5, Service Level Verification Options).

Main Menu→Configuration→System→Service Level Verification

Table 3-5. Service Level Verification Options (1 of 3)

SLV Sample Interval (secs)

Possible Settings10 – 3600 Default Setting: 60

Sets the inband communications interval between FrameSaver SLV devices. Inband communications are used to pass frames that calculate latency, as well as transmission success and other SLV information.

10. 3600 – Sets the SLV Sample Interval (secs) in seconds.
Available SettingsTributary, Controller, None Default Setting: Tributary

Determines the role the unit plays in maintaining synchronization of user history data collection and storage between FrameSaver devices.

Tributary – Uses network timing received from incoming SLV communications and provides network-based synchronization information to other devices in the network.

Controller – Uses its own internal time-of-day clock and provides synchronization information to other devices in the network based upon its own clock.

None – Incoming timing information is ignored and no timing information is sent out. This setting should only be used when network synchronization is not desirable, or when a single unit connects multiple networks or network segments.

Available SettingsStandard, COS 1–COS 7 Default Setting:
If SLV Feature is enabledStandard If SLV Feature is disabled: COS 1

Determines the type of SLV measurements to which these other SLV options apply:

SLV Timeout Error Event Threshold

SLV Timeout Clearing Event Threshold

SLV Round Trip Latency Error Threshold

SLV Latency Clearing Event Threshold

SLV Packet Size

Standard – The options selected apply to standard FrameSaver SLV measurements, utlizing an EDLCI for FrameSaver-to-FrameSaver communication. This option is not available if the SLV Feature is disabed or if Service Type is PPP.

COS 1–COS 7 – The options selected apply to this Class of Service. Different settings may be saved for each Class of Service.

SLV Synchronization Role · SLV Type

Page 44 of the Paradyne 9623 user manual — Table 3-5. Service Level Verification Options (2 of 3)
Page 44 · click to enlarge
Page 44

Table 3-5. Service Level Verification Options (2 of 3)

Possible SettingsEnable, Disable Default Setting: Disable

Determines whether communication of Frame and Data Delivery Ratios (FDR/DDR) between FrameSaver SLV devices is enabled. To use this capability, both ends of all PVCs must be FrameSaver SLV devices. If some of the units are FrameSaver 9124s or 9624s, they must be running software version 1.2 or higher.

Display Conditions – This option appears only if SLV Type is Standard and Service Type is not PPP.

Enable – An extra byte for FDR/DDR statistics collection is included with each frame, which is used at the receiving end to determine the amount of data dropped by the network.

Disable – Extra byte is not included.

DLCI Down on SLV Timeout

Available SettingsEnable, Disable Default Setting: Disable

Determines whether missed SLV packets will be monitored along with the LMI status to determine the status of PVC connections to remote FrameSaver units.

Display Conditions – This option appears only if SLV Type is Standard and Service Type is not PPP.

Enable – After the configured threshold for missed SLV packets has been exceeded, causing the DLCI’s status to turn Inactive, an alarm and SNMP trap are generated, and a Health and Status message created.

Disable – Missed SLV packets are monitored, but the DLCI is not declared down.

SLV Timeout Error Event Threshold

Available Settings1, 2, 3, 4 . . . 20 Default Setting: 3

Specifies the number of consecutive missed SLV communications that must be detected before a DLCI Inactive status is declared.

1–20 – Sets the limit for these error events.

SLV Timeout Clearing Event Threshold

Available Settings1, 2, 3, 4 . . . 20 Default Setting: 1

Specifies the number of consecutive SLV messages that must be received before the DLCI Inactive status is cleared.

1. 20 – Sets the limit for the clearing event.

SLV Delivery Ratio

Page 45 of the Paradyne 9623 user manual — Table 3-5. Service Level Verification Options (3 of 3)
Page 45 · click to enlarge
Page 45

Table 3-5. Service Level Verification Options (3 of 3)

SLV Round Trip Latency Error Threshold (ms)

Available Settings50, 51, 52, . . . 10000 Default Setting: 10000

Specifies the number of milliseconds that must be exceeded before an SLV Latency Threshold alarm event is declared and backup, if configured, is initiated for a DLCI.

If SLV Type is Standard, the latency applies to a multiplexed DLCI.

If SLV Type is a Class of Service (COS 1 – COS 7), the latency applies to the COS on an IP Enabled path.

50–10000 – Sets the limit for these error events.

SLV Latency Clearing Event Threshold

Available Settings1, 2, 3, 4 . . . 20 Default Setting: 2

Specifies the number of consecutive SLV latency measurements below the error threshold that must be received before the error status is cleared.

1. 20 – Sets the limit for the clearing event.

SLV Packet Size (bytes)

Available Settings64 – 2048 Default Setting: 64

Sets the size of packets, in bytes, that will be used for SLV communications. SLV packets are used to track latency and other SLV-related variables.

When the packet size is changed, a new round trip and average latency calculation must be performed, so these measurements will not appear on the SLV Performance Statistics screen until a new sampling interval has occurred.

64. 2048 – Sets the packet size for SLV communications.
Page 46 of the Paradyne 9623 user manual — Table 3-6. General System Options (1 of 3)
Page 46 · click to enlarge
Page 46

Configuring General System Options

Select General from the System menu to configure the general system configuration options (see Table 3-6, General System Options).

Main Menu→Configuration→System→General

Table 3-6. General System Options (1 of 3)

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether or not loopback and pattern tests have a duration after which they are terminated automatically.

Enable – All Loopback and Pattern tests have a timeout. This setting is recommended when the FrameSaver unit is managed remotely through an in-band data stream. If the FrameSaver unit is accidently commanded to execute a disruptive test on the interface providing the management access, control can be regained after the timeout expires, terminating the test.

Disable – Loopback and pattern tests must be manually terminated.

Possible Settings1 – 120 Default Setting: 10

Specifies the maximum duration of the tests.

Display Conditions – This option only appears when Test Timeout is set to Enable.

1. 120 – Sets the Test Timeout period in minutes (inclusive).
Possible SettingsNet1, DSX, Internal, DBM Default Setting: Net1

Allows you to select the primary clock source for the unit. The source selected provides all of the timing within the FrameSaver unit and the clocks for all of the external interfaces. Failure of the clock specified by this configuration option results in automatic fallback to the Secondary Clock Source configuration option setting.

Net1 – The primary clock is derived from the Network1 T1 interface.

DSX – The primary clock for the unit is derived from the DSX-1 interface. This setting only appears if the DSX-1 interface is enabled (see Configuring the T3 User Port (9520-ILM) on page 3-41).

Internal – The primary clock is the internal clock.

DBM – The primary clock is derived from the DBM. This selection only appears if the DBM is installed and enabled.

Test Timeout · Test Duration (min) · Primary Clock Source

Page 47 of the Paradyne 9623 user manual — Table 3-6. General System Options (2 of 3)
Page 47 · click to enlarge
Page 47

Table 3-6. General System Options (2 of 3)

Possible SettingsNet1, DSX, Internal, DBM Default Setting: Internal

Provides a secondary clock source when the primary clock source fails. The source selected for this configuration option provides all of the timing within the unit and the clocks for all of the external interfaces.

The clock source will switch back to primary when the primary clock source returns and is stable for 10 seconds. If the secondary clock source fails, the clock source will switch to internal. The clock source will switch back to primary when the primary clock source returns and is stable for 10 seconds.

Net1 – The secondary clock is derived from the Network1 T1 interface.

DSX – The secondary clock for the unit is derived from the DSX-1 interface. This setting only appears if the DSX-1 interface is enabled.

Internal – The secondary clock is the internal clock.

DBM – The secondary clock is derived from the DBM. This selection only appears if the DBM is installed and enabled.

Secondary Clock Source

Page 48 of the Paradyne 9623 user manual — Table 3-6. General System Options (3 of 3)
Page 48 · click to enlarge
Page 48

Table 3-6. General System Options (3 of 3)

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether an alarm condition for the unit will activate the system alarm relay. The alarm relay is deactivated when the condition causing the alarm is corrected. If more than one alarm condition is present, the alarm relay remains active until all alarm conditions are cleared.

You can also deactivate an alarm via the System Alarm Relay Cut-Off selection from the Control menu; however, the alarm itself is not cleared. When another alarm condition is detected, the alarm is reactivated again, requiring another manual deactivation of the alarm relay.

Display Conditions – This option only appears for a FrameSaver SLV 9128 installed in the 9000 Series Access Carrier.

Alarm conditions are:

Alarm Indication Signal (AIS) received at the Network, DSX-1, or PRI interface

Continuous Loss of Signal (LOS) condition at the Network, DSX-1, or PRI interface

DBM Download Required

DBM BRI Card Failed

Ethernet Link Down

Excessive Error Rate (EER) detected at the Network or PRI interface

Internal Modem Failed

ISDN Network Failure

Network Communication Link Down

Out of Frame (OOF) at Network, DSX-1, or PRI

Primary or Secondary Clock Failure

Power Supply/Fan Failure

SLV Latency Exceeded

Suboptimal (Maximum) Link Rate Cannot be Achieved

Two Level-1 Users Accessing Device

Yellow Alarm Signal on the Network, DSX-1, or PRI interface

Enable – Activates alarm conditions on the system alarm relay when an alarm condition occurs.

Disable – Does not activate the system alarm relay when an alarm condition occurs.

Show 9 more labels / short text on this page
System Alarm Relay · CTS Down · Device Fail · DLCI Down · DTR Down · LMI Down · RTS Down · Self-Test Failure · SLV Timeout
Page 49 of the Paradyne 9623 user manual — Configuring the Network Interface
Page 49 · click to enlarge
Page 49

Configuring Physical Interfaces

Characteristics for physical interfaces are explained in the following sections:

Configuring the Network Interface

Configuring a User Data Port (CSU/DSUs)

Configuring the T3 User Port (9520-ILM)

Configuring the DSX-1 Interface (9126, 9128)

Configuring the ISDN DBM Interface (9126, 9128, 9626)

Configuring the Network Interface

When configuring the physical characteristics for the network interface, select Physical from the Network menu.

Main Menu→Configuration→Network→Physical

See:

Table 3-7, T1 Network Physical Interface Options (9123, 9126, 9128)

Table 3-8, T3 Network Physical Interface Options (9520, 9520-ILM)

Table 3-9, DDS Network Physical Interface Options (9623, 9626)

Table 3-10, IDSL Network Physical Interface Options (9720)

Table 3-11, SDSL Network Physical Interface Options (9783, 9783 Router)

Table 3-12, SHDSL Network Physical Interface Options (9788, 9788 Router)

Table 3-13, Synchronous Network Data Port Physical Interface Options (9820-2M, 9820-8M)

Table 3-14, HSSI Network Data Port Physical Interface Options (9820-45M)

Page 50 of the Paradyne 9623 user manual — Table 3-7. T1 Network Physical Interface Options (1 of 4)
Page 50 · click to enlarge
Page 50

T1 Network Interface

FrameSaver Models 9123, 9126, and 9128 have a T1 network interface.

Table 3-7. T1 Network Physical Interface Options (1 of 4)

Possible SettingsD4, ESF Default Setting: ESF

Specifies the framing format for transmitted and received signals on the T1 network interface.

D4 – Uses D4 framing format.

ESF – Uses Extended Superframe framing format.

Possible SettingsAMI, B8ZS Default Setting: B8ZS

Specifies the line coding format for the network interface.

AMI – Uses Alternate Mark Inversion (AMI) line coding format.

B8ZS – Uses Bipolar 8 Zero Substitution (B8ZS) line coding format.

Possible Settings0.0, –7.5, –15, –22.5 Default Setting: 0.0

Specifies the line build out for the signal transmitted to the network.

0.0, –7.5, –15, –22.5 – Specifies line build out in dB.

Possible Settings62411, Disable Default Setting: 62411

Determines the type of bit insertion to provide ones density requirements for data transmitted to the network.

Display Conditions – This option does not appear when Line Coding Format is set to B8ZS.

62411 – Inserts a one in the data after 15 consecutive zeros are received or the density of ones falls below 12.5%. This setting complies with AT&T TR 62411, but is not recommended for frame relay data because it inserts errors in the data traffic.

Disable – Disables bit stuffing. Ones density is not enforced on data sent to the network.

Show 4 more labels / short text on this page
Line Framing Format · Line Coding Format · Line Build Out · Bit Stuffing
Page 51 of the Paradyne 9623 user manual — Table 3-7. T1 Network Physical Interface Options (2 of 4)
Page 51 · click to enlarge
Page 51

Table 3-7. T1 Network Physical Interface Options (2 of 4)

Possible SettingsSystem, Interface Default Setting: System

Allows transmit timing to be selected from either the system master clock source or from the currently selected interface.

System – Transmit timing is derived from the current system clock source (see Table 3-6, General System Options).

Interface – Transmit timing is derived from this interface.

Possible SettingsEnable, Disable Default Setting: Enable

Allows the initiation and termination of the line loopback (LLB) to be controlled by the receipt of LLB-Actuate and LLB-Release commands from the network.

Enable – LLB is controlled by LLB-Actuate and LLB-Release commands. Receiving a LLB-Actuate command causes the FrameSaver unit to enter a line loopback (provided an LLB can be performed in the FrameSaver unit’s current state). Receiving an LLB-Release command terminates the LLB.

Disable – The FrameSaver unit ignores the LLB-Actuate and LLB-Release commands.

Possible SettingsEnable, Disable Default Setting: Enable

Allows the initiation and termination of the payload loopback (PLB) to be controlled by the receipt of PLB-Actuate and PLB-Release commands from the network.

Display Conditions – This option only appears when Line Framing Format is set to ESF.

Enable – PLB is controlled by PLB-Actuate and PLB-Release commands. Receiving a PLB-Actuate command causes the system to enter a payload loopback (provided a PLB can be performed in the unit’s current state). Receiving a PLB-Release command terminates the PLB.

Disable – The FrameSaver unit ignores the PLB-Actuate and PLB-Release commands.

Transmit Timing · Network Initiated LLB · Network Initiated PLB

Page 52 of the Paradyne 9623 user manual — Table 3-7. T1 Network Physical Interface Options (3 of 4)
Page 52 · click to enlarge
Page 52

Table 3-7. T1 Network Physical Interface Options (3 of 4)

Possible SettingsDisable, V.54_&_ANSI Default Setting: V.54_&_ANSI

Allows the initiation and termination of the Data Channel Loopback (DCLB V.54 Loop 2) to be controlled by the receipt of a DCLB-actuate or DCLB-release sequence (either V.54 or FT1-ANSI compliant) from the network on the DS0s used for the network frame relay link. When enabled and a DCLB-activate sequence is received, the unit initiates a DCLB on the network interface. When a DCLB-release sequence is received, the DCLB is stopped.

Disable – DCLB-actuate and DCLB-release sequences are ignored.

V.54_&_ANSI – DCLB-actuate and DCLB-release sequences that comply with either V.54 or ANSI T1.403, Annex B standard will be recognized and will control initiation and termination of a DCLB for the network frame relay link. The actuate and release sequences do not need to match (for example, a DCLB started with a V.54 actuate sequence can be stopped with an FT1 release sequence).

ANSI Performance Report Messages

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether ANSI T1.403 compliance performance report messages (PRMs) are generated and sent to the network over the ESF facility data link every second.

Display Conditions – This option only appears when Line Framing Format is set to ESF.

Enable – Generates and sends PRMs.

Disable – Does not generate and send PRMs.

Network Initiated DCLB

Page 53 of the Paradyne 9623 user manual — Table 3-7. T1 Network Physical Interface Options (4 of 4)
Page 53 · click to enlarge
Page 53

Table 3-7. T1 Network Physical Interface Options (4 of 4)

Excessive Error Rate Threshold

Possible Settings10E-4, 10E-5, 10E-6, 10E-7, 10E-8, 10E-9 Default Setting: 10E-4

Sets the error rate threshold that determines when an EER condition is declared. The excessive error rate is determined by the ratio of the number of CRC6 errors to the total number of bits received over a set period of time.

Display Conditions – This option only appears when Line Framing Format is set to ESF.

10E-4 – Declares an EER if more than 1,535 CRC6 errors are detected in a 10 second period. Clears when fewer than 1,536 CRC6 errors are detected within the same time period.

10E-5 – Declares an EER if more than 921 CRC6 errors are detected in a 60 second period or a 10-4 condition occurs. Clears when fewer than 922 CRC6 errors are detected within the same time period.

10E-6 – Declares an EER if more than 92 CRC6 errors are detected in a 60 second period or a 10-5 or 10-4 condition occurs. Clears when fewer than 93 CRC6 errors are detected within the same time period.

10E-7 – Declares an EER if more than 9 CRC6 errors are detected in a 60 second period or a 10-6, or 10-5, or 10-4 condition occurs. Clears when fewer than 10 CRC6 errors are detected within the same time period.

10E-8 – Declares an EER if more than 41 CRC6 errors are detected in three 15 minute intervals or a 10-7, 10-6, 10-5, 10-4 condition occurs. Clears when fewer than 42 CRC6 errors are detected within the same time period.

10E-9 – Declares an EER if more than 4 CRC6 errors are detected in three 15 minute intervals or a 10-8, 10-7, 10-6, 10-5, or 10-4 condition occurs. Clears when fewer than 5 CRC6 errors are detected within the same time period.

Possible SettingsASCII Text Entry , Clear Default Setting: blank

Identifies the transmission vendor’s circuit information to facilitate troubleshooting.

ASCII Text Entry – Edit or display circuit identifier information (maximum 255 characters).

Clear – Removes the circuit identifier information.

Circuit Identifier

Page 54 of the Paradyne 9623 user manual — Table 3-8. T3 Network Physical Interface Options
Page 54 · click to enlarge
Page 54

T3 Network Interface

FrameSaver Models 9520 and 9520-ILM have a T3 network interface.

Table 3-8. T3 Network Physical Interface Options

Possible SettingsASCII Text Entry , Clear Default Setting: blank

Identifies the transmission vendor’s circuit information to facilitate troubleshooting.

ASCII Text Entry – Edit or display circuit identifier information (maximum 255 characters).

Clear – Removes the circuit identifier information.

Possible SettingsShort, Long Default Setting: Short

Specifies the line build out for the signal transmitted to the network.

Short – Activates an equalization filter to simulate a longer cable. Use this option for a network cable less than 100 feet.

Long – The equalization filter is bypassed. Use this option for a network cable 100 feet or longer.

Possible SettingsEnable, Disable Default Setting: Enable

Allows the initiation and termination of the line loopback (LLB) to be controlled by the receipt of LLB-Actuate and LLB-Release commands from the network.

Enable – LLB is controlled by LLB-Actuate and LLB-Release commands. Receiving a LLB-Actuate command causes the FrameSaver unit to enter a line loopback (provided an LLB can be performed in the FrameSaver unit’s current state). Receiving an LLB-Release command terminates the LLB.

Disable – The FrameSaver unit ignores the LLB-Actuate and LLB-Release commands.

Circuit Identifier · Line Build Out · Network Initiated LLB

Page 55 of the Paradyne 9623 user manual — Table 3-9. DDS Network Physical Interface Options (1 of 2)
Page 55 · click to enlarge
Page 55

DDS Network Interface

FrameSaver Models 9623 and 9626 have a DDS network interface.

Table 3-9. DDS Network Physical Interface Options (1 of 2)

Possible SettingsInternal, Receive Default Setting: Receive

Specifies the unit’s timing source based upon how the unit will be used. When the unit is connected to a DDS (Digital Data Service) network for standard operation, timing is provided by the network. In a LADS, or LDM, application (local area data set/limited distance modem), where local and remote FrameSaver units are directly connected, one of the units provides timing for both units.

Internal – Timing for the unit and its attached LADS partner is derived from the unit’s internal clock. Use this setting when the unit will be used as a LADS primary timing unit, where the FrameSaver unit establishes overall timing for the two interconnected units.

Receive – Timing for the unit is derived from the network Received signal. Use this setting for standard DDS operation, or when the unit will be used as a LADS secondary timing unit. See DDS Line Rate (Kbps).

Possible SettingsAuto_On_No_Signal, Initialize_From_Network, 56, 64CC Default Setting: Auto_On_No_Signal

Configures the network interface’s line speed to match the Digital Data Service’s (DDS’s) line speed. This is the rate at which data is transmitted over the DDS line.

Display Conditions – This option only appears when Transmit Timing is set to Receive.

Auto_On_No_Signal – Automatically detects the line rate on the network interface whenever a No Signal alarm is declared, the unit is reset, or the line rate is changed to Auto_On_No_Signal and saved, then changes the unit’s operating rate to match the network’s. It may take up to 15 seconds each time automatic rate detection and adjustment occurs.

Initialize_From_Network – Automatically detects the line rate on the network interface once, then changes the unit’s operating rate to match the network’s. Automatic rate detection and adjustment, or Autobaud, will not occur again unless the line rate is changed to Initialize_From_Network or Auto_On_No_Signal and saved. It may take up to 15 seconds for automatic rate detection and adjustment to occur.

56. Forces the line rate to 56 Kbps.

64CC – Forces the line rate to 64 Kbps Clear Channel (72 Kbps on the line).

Transmit Timing · DDS Line Rate

Page 56 of the Paradyne 9623 user manual — Table 3-9. DDS Network Physical Interface Options (2 of 2)
Page 56 · click to enlarge
Page 56

Table 3-9. DDS Network Physical Interface Options (2 of 2)

Possible SettingsDisable, V.54_&_ANSI Default Setting: V.54_&_ANSI

Allows the initiation and termination of the Data Channel Loopback (DCLB V.54 loop 2) to be controlled by the receipt of a DCLB-actuate or DCLB-release sequence (either V.54 or FT1-ANSI compliant) from the network or a far-end FrameSaver device. When enabled and a DCLB-activate sequence is received, the unit initiates a DCLB on the network interface. When a DCLB-release sequence is received, the DCLB is stopped.

Disable – DCLB-actuate and DCLB-release sequences are ignored.

V.54_&_ANSI – DCLB-actuate and DCLB-release sequences that comply with either V.54 or ANSI T1.403, Annex B standard will be recognized and will control initiation and termination of a DCLB for this frame relay link. The actuate and release sequences do not need to match (for example, a DCLB started with a V.54 actuate sequence can be stopped with an FT1 release sequence).

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether the FrameSaver unit responds to the DSU Latching Loopback sequence sent by the network, as specified by TR62310.

Enable – Responds to DSU latching loopback commands. The unit remains in loopback until the network receives the loopback release sequence.

Disable – Does not respond to the DSU loopback commands, or terminates the latching loopback test if it is active.

Require DSU Latching Loopback Preamble

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether the FrameSaver unit requires the ANSI or FRF proposed preamble for the network-initiated DSU Latching Loopback when detecting the loopback sequence.

Display Conditions – This option only applies when the unit is operating on a standard DDS 64KCC circuit and DSU Latching Loopback (64KCC) is enabled.

Enable – Does not respond to the DSU Latching Loopback commands unless the preamble is received.

Disable – Responds to DSU Latching Loopback commands, whether or not the preamble is received.

Network Initiated DCLB · DSU Latching Loopback

Page 57 of the Paradyne 9623 user manual — Table 3-10. IDSL Network Physical Interface Options
Page 57 · click to enlarge
Page 57

IDSL Network Interface

FrameSaver Model 9720 has an IDSL network interface.

Table 3-10. IDSL Network Physical Interface Options

Possible SettingsAutoRate, 64, 128, 144 Default Setting: AutoRate

Specifies the IDSL line rate.

AutoRate – The line rate is automatically detected when the frame relay LMI is brought up on one or both channels.

64. The line rate is 64 kbps. One B channel is used for the data transfer, and automatic rate detection is disabled.
128. The line rate is 128 kbps. Both B channels are used for the data transfer, and automatic rate detection is disabled.
144. The line rate is 144 kbps. Both B channels are used for the data transfer, and automatic rate detection is disabled.
Possible SettingsB1, B2 Default Setting: B1

Specifies the B channel used for data transfer when the line rate is 64 kbps.

Display Conditions – Channel appears only when Operating Rate is set to 64.

B1 – The B1 channel is used for data transfer.

B2 – The B2 channel is used for data transfer.

Operating Rate · Channel

Page 58 of the Paradyne 9623 user manual — Table 3-11. SDSL Network Physical Interface Options
Page 58 · click to enlarge
Page 58

SDSL Network Interface

The FrameSaver DSL 9783 CSU/DSU and Router have an SDSL network interface.

Table 3-11. SDSL Network Physical Interface Options

Possible SettingsHunt, AutoRate, Fixed Default Setting: AutoRate

Specifies the mode to be used for rate selection.

Hunt – The unit attempts to train at rate specified by DSL Line Rate. If that fails, the unit attempts to train at the next higher rate, and, if unsuccessful, cycles through all the rates until training is successful or the unit is reset.

AutoRate – The unit automatically detects the line rate from the network interface.

Fixed – The unit uses the line rate specified by DSL Line Rate.

DSL Line Rate (Kbps)

Possible Settings:

– If DSLAM Type is set to Paradyne, or if DSLAM Type is set to Nokia and Line Rate

Mode is set to Fixed: 144, 192, 208, 256, 272, 384, 400, 512, 528, 768, 784, 1024, 1152, 1168, 1536, 1552, 2320

– If DSLAM Type is set to Alcatel (NewBridge): 208, 400, 784, 1168, 1552, 2320 – If DSLAM Type is set to Nokia and Line Rate Mode is set to Hunt: 192, 384, 768,

1152, 1536 – If DSLAM Type is set to PairGain: 144, 192, 208, 256, 272, 384, 400, 512, 528,

768, 784, 1024, 1152, 1168, 1536, 1552, 2320

Default Setting:

– If DSLAM Type is set to Alcatel (NewBridge) and Line Rate Mode is set to Hunt: 208 – If DSLAM Type is set to Nokia and Line Rate Mode is set to Hunt: 384

– If DSLAM Type is set to PairGain and Line Rate Mode is set to Fixed: 784 – (If DSLAM Type is set to Paradyne, Line Rate Mode is set to AutoRate and DSL

Line Rate does not appear)

Determines the rate on the DSL network interface (if Line Rate Mode is Fixed), or the rate the device will first use to attempt to train (if Line Rate Mode is Hunt).

Display Conditions – DSL Line Rate does not appear if DSL Line Rate Mode is set to AutoRate.

144. 2320 – The DSL line rate is set to the specified rate in Kbps.

SNR Margin Alarm Threshold (dB)

Possible Settings: –5, –4, –3, –2, –1, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Default Setting: 3

Specifies the level in decibels at which a Signal to Noise Ratio (SNR) margin alarm condition is declared.

–5 – 10 – Specifies the threshold level in dB.

Line Rate Mode

Page 59 of the Paradyne 9623 user manual — Table 3-12. SHDSL Network Physical Interface Options (1 of 2)
Page 59 · click to enlarge
Page 59

SHDSL Network Interface

The FrameSaver DSL 9788 CSU/DSU and Router have an SHDSL network interface.

Table 3-12. SHDSL Network Physical Interface Options (1 of 2)

Possible SettingsAutoRate, Fixed Default Setting: AutoRate

Specifies the mode to be used for rate selection.

AutoRate – The unit automatically detects the line rate from the network interface.

Fixed – The unit uses the line rate specified by DSL Line Rate.

DSL Line Rate (Kbps)

Possible Settings:

– If PSD Mask is Symmetric: 200, 264, 328, 392, 456, 520, 584, 648, 712, 776, 784,

840, 904, 968, 1032, 1096, 1160, 1224, 1288, 1352, 1416, 1480, 1544, 1552, 1608, 1672, 1736, 1800, 1864, 1928, 1992, 2056, 2120, 2184, 2248, 2312 – If PSD Mask is Asymmetric (available in future release) and Region is Annex A:

776, 784, 1544, 1552 – If PSD Mask is Asymmetric (available in future release) and Region is Annex B:

Default Setting[Depends on settings of Line Rate Mode, PSD Mask, and Region]

Determines the rate on the DSL network interface. Valid rates, and the rates presented on the screen, depend on the values of Region and PSD Mask. If a change to another configuration option renders the selected DSL Line Rate invalid, the Line Rate Mode is set to AutoRate.

Display Conditions – DSL Line Rate does not appear if DSL Line Rate Mode is set to AutoRate.

200. 2312 – The DSL line rate is set to the specified rate in Kbps.
Possible SettingsAnnex A, Annex B Default Setting: [Depends on model]

Determines the annex of the G.991.2 recommendation that the unit will conform to. The value of Region in part determines what DSL Line Rates are available. If a change in the Region renders the current DSL Line Rate invalid, the Line Rate Mode is set to AutoRate.

Annex A – The unit conforms to Annex A (for North America).

Annex B – The unit conforms to Annex B (for Europe).

Line Rate Mode · 2056, 2312 · Region

Page 60 of the Paradyne 9623 user manual — Table 3-13. Synchronous Network Data Port Physical Interface Options (1 of 2)
Page 60 · click to enlarge
Page 60

Table 3-12. SHDSL Network Physical Interface Options (2 of 2)

Possible SettingsSymmetric Default Setting: Symmetric

Read-only. Specifies the Power Spectral Density (PSD) mask the unit will use. The value of PSD Mask in part determines what DSL Line Rates are available. If a change in the PSD Mask setting (available in a future release) renders the current DSL Line Rate invalid, the Line Rate Mode is set to AutoRate.

Asymmetric – (Future use.) The unit uses the asymmetric PSD mask.

Symmetric – The unit uses the symmetric PSD mask.

Synchronous Network Interface

FrameSaver Models 9820-2M and 9820-8M have an EIA-530-A network interface.

Table 3-13. Synchronous Network Data Port Physical Interface Options (1 of 2)

Possible SettingsE530, V.35, X.21 Default Setting: V.35

Selects the type of port to be used for the network data port.

E530 – The port is configured as an EIA-530-A-compatible DTE. An EIA-530-A-compatible DCE can be directly connected to the DB25 connector for this port on the rear of the FrameSaver unit.

V.35 – The port is configured as a V.35-compatible DTE. A V.35-compatible DCE can be connected to the DB25 connector for this port using an adapter cable on the rear of the FrameSaver unit.

X.21 – The port is configured as a V.11/X.21-compatible DTE. A V.11/X.21-compatible DCE can be connected to the DB25 connector for this port using an adapter cable on the rear of the FrameSaver unit.

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether the internal clock (used for timing data transmitted to the DCE) will be phase-inverted with respect to the clock received at the interface. This option is useful when long cable lengths between the FrameSaver device and the DCE are causing errors.

Enable – The internal clock used to transmit data to the DCE is phase inverted with respect to the clock supplied by the DCE to this port.

Disable – The internal clock is not inverted (normal).

PSD Mask · Port Type · Invert Internal Clock

Page 61 of the Paradyne 9623 user manual — Table 3-13. Synchronous Network Data Port Physical Interface Options (2 of 2)
Page 61 · click to enlarge
Page 61

Table 3-13. Synchronous Network Data Port Physical Interface Options (2 of 2)

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether the state of the DCE Ready (DSR) circuit on the network data port will be used to determine when valid data communication is possible with the unit. When this condition is detected, an alarm is generated, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

Display Conditions – This option does not appear when Port Type is set to X.21. The signal is assumed to be asserted.

Enable – Interchange circuit CC (ITU/CCITT 107) – DSR is monitored to determine when valid data is being sent from the DCE.

Disable – DSR is not monitored. DSR is assumed to be asserted and data is transmitted, regardless of the actual state of the lead.

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether the state of the Clear to Send (CTS) circuit on the network data port will be used to determine when valid data communication is possible with the unit. When this condition is detected, an alarm is generated, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

Display Conditions – This option does not appear when Port Type is set to X.21. The signal is assumed to be asserted.

Enable – Interchange circuit CB (ITU/CCITT 106) – CTS is monitored to determine whether data should be transmitted to the DCE.

Disable – CTS is not monitored. CTS is assumed to be asserted and data is transmitted, regardless of the actual state of the lead.

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether the state of the Received Line Signal Detector (RLSD) circuit on the network data port will be used to determine when valid data communication is possible with the unit. When this condition is detected, an alarm is generated, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

If Port Type is set to X.21, the Indication interchange circuit is monitored instead of RLSD.

Enable – Interchange circuit CF (ITU/CCITT 109) – RLSD is monitored to determine when valid data communication is possible with the DCE.

Disable – RLSD is not monitored. RLSD is assumed to be asserted and data is transmitted, regardless of the actual state of the lead.

Monitor DSR · Monitor CTS · Monitor RLSD

Page 62 of the Paradyne 9623 user manual — Table 3-14. HSSI Network Data Port Physical Interface Options
Page 62 · click to enlarge
Page 62

HSSI Network Interface

FrameSaver Model 9820-45M has a HSSI network interface.

Table 3-14. HSSI Network Data Port Physical Interface Options

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether the state of the DCE Ready (DSR) circuit on the network data port will be used to determine when valid data communication is possible with the unit. When this condition is detected, an alarm is generated, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

Enable – Interchange circuit CC (ITU/CCITT 107) – DSR is monitored to determine when valid data is being sent from the DCE.

Disable – DSR is not monitored. DSR is assumed to be asserted and data is transmitted, regardless of the actual state of the lead.

Monitor DSR

Page 63 of the Paradyne 9623 user manual — Table 3-15. V.35 Data Port Physical Interface Options (1 of 6)
Page 63 · click to enlarge
Page 63

Configuring a User Data Port (CSU/DSUs)

Select Physical from the Data Ports menu to display or change the physical characteristics of the data port connected to the DTE.

Main Menu→Configuration→Data Ports→Physical

See:

Table 3-15, V.35 Data Port Physical Interface Options

Table 3-16, EIA-530-A/X.21/V.35 Data Port Physical Interface Options

Table 3-17, HSSI Data Port Physical Interface Options

V.35 Data Port Physical Interface

FrameSaver Models 9123, 9126, 9623, 9626, and 9783 have a V.35 data port. The Model 9128 standalone and carrier-mounted units have two V.35 data ports.

Table 3-15. V.35 Data Port Physical Interface Options (1 of 6)

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether the data port is being used and can be configured.

Enable – The port is active, and can be used to transmit and receive data.

Disable – The port is not active. When the port is disabled, the following will occur:

No alarms or traps configured for the port will be generated.

LED for the port will be held in an Off state.

No – The operation is canceled. (Pressing either the Esc or Ctrl-a key also acts as a No.)

Yes – Port status is disabled.

Port Type (9788, 9820-2M, 9820-8M)

Possible SettingsE530, V.35, X.21 Default Setting: V.35

Specifies the port type of the data port.

E530 – The port is configured as an EIA-530-A-compatible DCE. An EIA-530-A- compatible DTE may be directly connected to the DB25 connector for the port.

V.35 – The port is configured as a V.35-compatible DCE. A V.35-compatible DTE may be connected to the port using a DB25-to-MS34 adapter.

X.21 – The port is configured as an X.21-compatible DCE. An X.21-compatible DTE may be connected to the port using a DB25-to-DB15 adapter.

Port Status

Page 64 of the Paradyne 9623 user manual — Table 3-15. V.35 Data Port Physical Interface Options (2 of 6)
Page 64 · click to enlarge
Page 64

Table 3-15. V.35 Data Port Physical Interface Options (2 of 6)

Possible SettingsFrame Relay, Synchronous Data

Default Setting: Frame Relay when the port supports frame relay. Synchronous Data when the port only supports synchronous data.

Determines how the data port will be used.

Display Conditions – This option only appears for user data on Port-2, and only when Service Type is Frame Relay.

Frame Relay – The port is configured for frame relay traffic. Frame relay links, DLCis, and PVC connections can be configured on this port.

Synchronous Data – The port is configured for standard TDM data, and can be cross-connected to a time slot on a T1 interface.

No alarms or traps configured for the port will be generated.

The LED for the port will be held in an Off state.

Existing cross-connect assignments associated with the port are cleared.

Max Port Rate (9128)

Possible Settings1536, 2048 Default Setting: 1536

Specifies the maximum clock rate for a user data port. The data rate for this port is limited to the rate specified by this option so that the maximum rate supported by an attached DTE is not exceeded.

Display Conditions – This option only appears when the Port Use is set to Frame Relay or PPP, the port rate is not otherwise configurable, and the selected port is Port-2.

1536 – The maximum port rate for the port is 1536 Kbps.

2048 – The maximum port rate for the port is 2048 Kbps.

Port Base Rate (9128)

Possible SettingsNx64, Nx56 Default Setting: Nx64

Specifies the base rate for the data port, which is a multiple (from 1 to 24) of the base rate specified by this option. N is a number from 1 to 24.

Display Conditions – This option only appears when Port Use is set to Synchronous Data.

Nx64 – The base rate for the port is 64 Kbps.

Nx56 – The base rate for the port is 56 Kbps.

Port Use (9128)

Page 65 of the Paradyne 9623 user manual — Table 3-15. V.35 Data Port Physical Interface Options (3 of 6)
Page 65 · click to enlarge
Page 65

Table 3-15. V.35 Data Port Physical Interface Options (3 of 6)

Possible SettingsAuto, Enable, Disable Default Setting: Auto

Determines whether the clock supplied by the FrameSaver unit on interchange circuit DB (ITU 114) – Transmit Signal Element Timing (DCE Source) TXC is phase inverted with respect to the clock used to time the incoming Transmitted Data (TD).

Auto – The port checks the clock supplied by the DCE on TXC on this port. If necessary, the port automatically phase inverts the clock with respect to the transmitted data.

Enable – Phase inverts the TXC clock. Use this setting when long cable lengths between the FrameSaver unit and the DTE are causing data errors.

Disable – Does not phase invert the TXC clock.

Possible SettingsInternal, External Default Setting: Internal

Determines whether the DTE’s transmitted data is clocked into the FrameSaver unit by its internal transmit clock or by the external clock provided by the DTE.

Internal – The FrameSaver unit uses the interchange circuit DB (ITU 114) – Transmit Signal Element Timing (TXC) (DCE source) for timing the incoming data.

External – The DTE provides the clock for the transmitted data, and the FrameSaver unit uses the interchange circuit DA (ITU 113) – Transmit Signal Element Timing (XTXC) (DTE source) for timing the incoming data.

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether the state of the Request To Send (RTS) circuits on the user data port will be used to determine when valid data communication is possible with the DTE. When this condition is detected, CTS is deasserted, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

Enable – Interchange circuit CA (ITU 105) – RTS is monitored to determine when valid data communication is possible with the DTE.

Disable – RTS is not monitored. RTS is assumed to be asserted and data is being transmitted, regardless of the state of the lead.

Invert Transmit Clock · Transmit Clock Source · Monitor RTS

Page 66 of the Paradyne 9623 user manual — Table 3-15. V.35 Data Port Physical Interface Options (4 of 6)
Page 66 · click to enlarge
Page 66

Table 3-15. V.35 Data Port Physical Interface Options (4 of 6)

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether the state of the DTE Ready (DTR) circuit on the user data port will be used to determine when valid data communication is possible with the DTE. When this condition is detected, an alarm is generated, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

Enable – Interchange circuit CD (ITU 108/1/2) – DTR is monitored to determine whether data should be transmitted to the DTE.

Disable – DTR is not monitored. DTR is assumed to be asserted and data is being transmitted, regardless of the state of the lead.

Port (DTE) Initiated Loopbacks

Possible Settings:

For Port-1, or Port-2 when Port Use is set to Frame Relay: Disable, Local For Port-2 when Port Use is set to Synchronous Data: Disable, DTPLB, DCLB, Both

Default SettingDisable
Possible SettingsLocal , Disable Default Setting: Disable

For Port-1, or Port-2 (9128 only) when Port Use is set to Frame Relay:

Allows a local external DTE Loopback to be started or stopped via the data terminal equipment attached to the port’s interchange lead LL (ITU 141), as specified by V.54.

Disable – The DTE attached to the port cannot control the local external DTE Loopback.

Local – The DTE attached to the port controls the local external DTE Loopback.

For Port-2 (9128 only) when Port Use is set to Synchronous Data:

Allows local Data Terminal Loopbacks (DTPLBs) and remote Data Channel Loopbacks (DCLBs) to be controlled by the DTE connected to this port.

Disable – The DTE attached to the port cannot control Local Data Terminal Loopbacks (DTPLBs) and remote Data Channel Loopbacks (DCLBs).

DTPLB – The DTE attached to the port controls DTPLBs via circuit LL – CCITT 141, as specified by V.54. The port remains in loopback as long as the circuit stays on.

DCLB – The DTE attached to the port controls DCLBs via circuit RL – CCITT 140, as specified by V.54. The far-end equipment must support inband V.54 loopbacks.

Both – The DTE attached to the port controls both local DTPLBs and remote DCLBs.

Monitor DTR

Page 67 of the Paradyne 9623 user manual — Table 3-15. V.35 Data Port Physical Interface Options (5 of 6)
Page 67 · click to enlarge
Page 67

Table 3-15. V.35 Data Port Physical Interface Options (5 of 6)

Invert Transmit and Receive Data (9128)

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether transmitted and received data for the synchronous data port is logically inverted before being transmitted or after being received from the network. Use this configuration option for applications where data is being transported using HDLC protocol, whereby inverting the data ensures that the ones density requirements for the network are met.

Display Conditions – This option only appears for Port-2 on a FrameSaver SLV 9128, when Port Use is set to Synchronous Data.

Enable – Inverts the transmitted and received data for the port.

Disable – Does not invert the transmitted and received data for the port.

Action on Network Yellow Alarm (9128)

Possible SettingsNone, Halt Default Setting: Halt

Specifies the action to take on the synchronous data port when a yellow alarm is received on the network interface. A yellow alarm indicates a problem with the signal being transmitted to the network.

Display Conditions – This option only appears for Port-2 on a FrameSaver SLV 9128, when Port Use is set to Synchronous Data.

None – No action taken when a yellow alarm is received.

Halt – Halts the transmission of data received on the synchronous data port and all ones are sent on circuit BB (ITU 104) – Receive Data (RD) and circuit CB (ITU 106) – Clear-to-Send (CTS) is deasserted to the port when a yellow alarm is received.

Page 68 of the Paradyne 9623 user manual — Table 3-16. EIA-530-A/X.21/V.35 Data Port Physical Interface Options (1 of 3)
Page 68 · click to enlarge
Page 68

Table 3-15. V.35 Data Port Physical Interface Options (6 of 6)

Network Initiated Data Channel Loopback (9128)

Possible SettingsDisable, V.54, ANSI_FT1, V.54_&_ANSI Default Setting: Disable

Allows the initiation and termination of the Data Channel Loopback (V.54 Loop 2) to be controlled by the receipt of a DCLB-actuate and DCLB-release sequence (either V.54, or FT1 [ANSI] compliant sequences) from the network or far end unit. When this configuration is enabled (V.54, FT1, or Both), receiving a DCLB-actuate sequence on a particular port causes the unit to initiate a DCLB on that port (provided that a DCLB can be performed based on the current state of the port and unit). Receiving a DCLB-release sequence terminates the DCLB.

Display Conditions – This option only appears for Port-2 on a FrameSaver SLV 9128, when Port Use is set to Synchronous Data.

Disable – Ignores the DCLB-actuate and DCLB-release for the port.

V.54 – DCLB-actuate and DCLB-release sequences that comply with the V.54 standard for “inter-DCE signaling for point-to-point circuits” are recognized and will control the initiation and termination of a DCLB (V.54 Loop 2) for the port.

ANSI_FT1 – DCLB-actuate and DCLB-release sequences that comply with either the ANSI.403, Annex B standard for “in-band signaling for fractional T1 (FT1) channel loopbacks” are recognized and will control the initiation and termination of a DCLB for the port.

V.54_&_ANSI – DCLB-actuate and DCLB-release sequences that comply with either the ANSI or V.54 standard are recognized and will control the initiation and termination of a DCLB for the port.

EIA-530-A/X.21/V.35 Data Port Physical Interface

FrameSaver Models 9788, 9820-2M, and 9820-8M have an EIA-530-A data port that can be adapted for use as an X.21 or V.35 data port.

Table 3-16. EIA-530-A/X.21/V.35 Data Port Physical Interface Options (1 of 3)

Possible SettingsE530, V.35, X.21 Default Setting: V.35

Specifies the port type of the data port.

E530 – The port is configured as an EIA-530-A-compatible DCE. An EIA-530-A- compatible DTE may be directly connected to the DB25 connector for the port.

V.35 – The port is configured as a V.35-compatible DCE. A V.35-compatible DTE may be connected to the port using a DB25-to-MS34 adapter.

X.21 – The port is configured as an X.21-compatible DCE. An X.21-compatible DTE may be connected to the port using a DB25-to-DB15 adapter.

Port Type

Page 69 of the Paradyne 9623 user manual — Table 3-16. EIA-530-A/X.21/V.35 Data Port Physical Interface Options (2 of 3)
Page 69 · click to enlarge
Page 69

Table 3-16. EIA-530-A/X.21/V.35 Data Port Physical Interface Options (2 of 3)

Possible SettingsInternal, External Default Setting: Internal

Determines whether the DTE’s transmitted data is clocked into the FrameSaver unit by its internal transmit clock or by the external clock provided by the DTE.

Internal – The FrameSaver unit uses the interchange circuit DB (ITU 114) – Transmit Signal Element Timing (TXC) (DCE source) for timing the incoming data.

External – The DTE provides the clock for the transmitted data, and the FrameSaver unit uses the interchange circuit DA (ITU 113) – Transmit Signal Element Timing (XTXC) (DTE source) for timing the incoming data.

Possible SettingsAuto, Enable, Disable Default Setting: Auto

Determines whether the clock supplied by the FrameSaver unit on interchange circuit DB (ITU 114) – Transmit Signal Element Timing (DCE Source) TXC is phase inverted with respect to the clock used to time the incoming Transmitted Data (TD).

Auto – The port will check the clock supplied by the DCE on TXC on this port. If necessary, the port will automatically phase invert the clock with respect to the transmitted data.

Enable – Phase inverts the TXC clock. Use this setting when long cable lengths between the FrameSaver unit and the DTE are causing data errors.

Disable – Does not phase invert the TXC clock.

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether the state of the DTE Ready (DTR) circuit on the user data port will be used to determine when valid data communication is possible with the DTE. When the DTR off condition is detected, an alarm is generated, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

Enable – Interchange circuit CD (ITU 108/1/2) – DTR is monitored to determine when valid data is sent from the DTE.

Disable – DTR is not monitored. DTR is assumed to be asserted and data is being transmitted, regardless of the state of the lead.

Transmit Clock Source · Invert Transmit Clock · Monitor DTR

Page 70 of the Paradyne 9623 user manual — Table 3-17. HSSI Data Port Physical Interface Options (1 of 3)
Page 70 · click to enlarge
Page 70

Table 3-16. EIA-530-A/X.21/V.35 Data Port Physical Interface Options (3 of 3)

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether the state of the Request To Send (RTS) circuits on the user data port will be used to determine when valid data communication is possible with the DTE. When the RTS off condition is detected, CTS is deasserted, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

Enable – Interchange circuit CA (ITU 105) – RTS is monitored to determine when valid data communication is possible with the DTE.

Disable – RTS is not monitored. RTS is assumed to be asserted and data is being transmitted, regardless of the state of the lead.

Port (DTE) Initiated Loopbacks (9520)

Possible SettingsLocal , Disable Default Setting: Disable

Allows a local external DTE Loopback to be started or stopped via the port’s attached data terminal equipment using the port’s interchange lead LL (ITU 141) for V.35, or LA (ITU 143) for HSSI.

Local – The DTE attached to the port controls the local external DTE Loopback.

Disable – The DTE attached to the port cannot control the local external DTE Loopback.

HSSI Data Port Physical Interface

FrameSaver Model 9520 has two HSSI data ports, and Model 9820-45M has one.

Table 3-17. HSSI Data Port Physical Interface Options (1 of 3)

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether the data port is being used and can be configured.

Enable – The port is active, and can be used to transmit and receive data.

Disable – The port is not active. When the port is disabled, the following will occur:

No alarms or traps configured for the port will be generated.

LED for the port will be held in an Off state.

No – The operation is canceled. (Pressing either the Esc or Ctrl-a key also acts as a No.)

Yes – Port status is disabled.

Monitor RTS · Port Status

Page 71 of the Paradyne 9623 user manual — Table 3-17. HSSI Data Port Physical Interface Options (2 of 3)
Page 71 · click to enlarge
Page 71

Table 3-17. HSSI Data Port Physical Interface Options (2 of 3)

Possible SettingsHSSI, V.35 Default Setting: HSSI

Specifies the port type of the data port.

V.35 – The port is configured as a V.35-compatible DCE. A V.35-compatible DTE may be connected to the port using a DB25-to-MS34 adapter.

HSSI – The port is configured as a HSSI-compatible DCE. A HSSI-compatible DTE may be directly connected to the DB25 connector for the port.

Possible Settings (HSSI)7456, 11184, 17250, 25875, 44736, 51750 Default Setting (HSSI): 51750

Possible Settings (V.35): 512, 1025, 1537, 2050, 2562, 3074, 3587, 4099, 4611, 5124, 5636, 6149, 6661, 7073, 7685, 8197 Default Setting (V.35): 6149

Selects the clock rate in kbps for the user data port.

Transmit Clock Source (9520)

Possible SettingsInternal, External Default Setting: Internal

Determines whether the DTE’s transmitted data is clocked into the FrameSaver unit by its internal transmit clock or by the external clock provided by the DTE.

Display Conditions – This option does not appear when Port Type is set to HSSI.

Internal – The FrameSaver unit uses the interchange circuit DB (ITU 114) – Transmit Signal Element Timing (TXC) (DCE source) for timing the incoming data.

External – The DTE provides the clock for the transmitted data, and the FrameSaver unit uses the interchange circuit DA (ITU 113) – Transmit Signal Element Timing (XTXC) (DTE source) for timing the incoming data.

Invert Transmit Clock (9520)

Possible SettingsAuto, Enable, Disable Default Setting: Auto

Determines whether the clock supplied by the FrameSaver unit on interchange circuit DB (ITU 114) – Transmit Signal Element Timing (DCE Source) TXC is phase inverted with respect to the clock used to time the incoming Transmitted Data (TD).

Display Conditions – This option does not appear when Port Type is set to HSSI.

Auto – The port will check the clock supplied by the DCE on TXC on this port. If necessary, the port will automatically phase invert the clock with respect to the transmitted data.

Enable – Phase inverts the TXC clock. Use this setting when long cable lengths between the FrameSaver unit and the DTE are causing data errors.

Disable – Does not phase invert the TXC clock.

Port Type (9520) · Port Rate (9520)

Page 72 of the Paradyne 9623 user manual — Table 3-17. HSSI Data Port Physical Interface Options (3 of 3)
Page 72 · click to enlarge
Page 72

Table 3-17. HSSI Data Port Physical Interface Options (3 of 3)

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether the state of the DTE Ready (DTR) circuit on the user data port will be used to determine when valid data communication is possible with the DTE. When the DTR off condition is detected, an alarm is generated, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

Enable – Interchange circuit CD (ITU 108/1/2) – DTR is monitored to determine when valid data is sent from the DTE.

Disable – DTR is not monitored. DTR is assumed to be asserted and data is being transmitted, regardless of the state of the lead.

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether the state of the Request To Send (RTS) circuits on the user data port will be used to determine when valid data communication is possible with the DTE. When the RTS off condition is detected, CTS is deasserted, LMI is declared down, and no further transfer of frame relay data can occur on this interface.

Display Conditions – This option does not appear when Port Type is set to HSSI.

Enable – Interchange circuit CA (ITU 105) – RTS is monitored to determine when valid data communication is possible with the DTE.

Disable – RTS is not monitored. RTS is assumed to be asserted and data is being transmitted, regardless of the state of the lead.

Port (DTE) Initiated Loopbacks

Possible SettingsLocal , Disable Default Setting: Disable

Allows a local external DTE Loopback to be started or stopped via the port’s attached data terminal equipment using the port’s interchange lead LL (ITU 141) for V.35 (9520 only), or LA (ITU 143) for HSSI.

Local – The DTE attached to the port controls the local external DTE Loopback.

Disable – The DTE attached to the port cannot control the local external DTE Loopback.

Monitor DTR · Monitor RTS (9520)

Page 73 of the Paradyne 9623 user manual — Table 3-18. T3 User Port Physical Interface Options
Page 73 · click to enlarge
Page 73

Configuring the T3 User Port (9520-ILM)

Select Physical to display or change the physical characteristics of the user data port connected to the DTE (see Table 3-18, T3 User Port Physical Interface Options).

Main Menu→Configuration→T3 User Ports→Physical

Table 3-18. T3 User Port Physical Interface Options

Possible SettingsShort, Long Default Setting: Short

Specifies whether a line equalization filter is activated to simulate a longer cable.

Short – The equalization filter is activated. Use this option for DTE cables less than 100 feet long.

Long – The equalization filter is not activated. Use this option for DTE cables 100 feet or longer.

Line Build Out

Page 74 of the Paradyne 9623 user manual — Table 3-19. DSX-1 Physical Interface Options (1 of 2)
Page 74 · click to enlarge
Page 74

Configuring the DSX-1 Interface (9126, 9128)

Select DSX-1 to display or change the physical configuration options when a DSX-1 interface is installed (see Table 3-19, DSX-1 Physical Interface Options).

Main Menu→Configuration→DSX-1

Table 3-19. DSX-1 Physical Interface Options (1 of 2)

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether the DSX-1 interface selected is available for use.

Enable – The interface is available.

Disable – The interface is not available for use. If there are time slots assigned to the DSX-1 interface when you attempt to disable it, the message This action will clear all DSX-1 Cross Connections. Are You Sure? No appears. If you select:

No – The operation is cancelled.

Yes – The following occurs:

All existing DSX-1 interface cross-connect assignments are cleared.

Alarms or traps associated with the DSX-1 interface are not generated.

LEDs associated with the DSX-1 interface are held in an “off’’ state.

Possible SettingsD4, ESF Default Setting: ESF

Specifies the framing format for transmitted and received signals on the DSX-1 interface.

D4 – Uses D4 framing format.

ESF – Uses Extended Superframe (ESF) framing format.

Possible SettingsAMI, B8ZS Default Setting: B8ZS

Specifies the line coding format for the DSX-1 interface.

AMI – Uses Alternate Mark Inversion (AMI) line coding format.

B8ZS – Uses Bipolar 8 Zero Substitution (B8ZS) line coding format.

Interface Status · Line Framing Format · Line Coding Format

Page 75 of the Paradyne 9623 user manual — Table 3-19. DSX-1 Physical Interface Options (2 of 2)
Page 75 · click to enlarge
Page 75

Table 3-19. DSX-1 Physical Interface Options (2 of 2)

Possible Settings0–133, 133–266, 266–399, 399–533, 533–655 Default Setting: 0–133

Permits a standard DSX signal to be delivered over a distance of up to 655 feet.

0–133 – Equalization on the DSX-1 side allows up to 133 feet of cable between the FrameSaver unit and the DTE.

133–266 – Equalization on the DSX-1 side allows up to 266 feet of cable between the FrameSaver unit and the DTE.

266–399 – Equalization on the DSX-1 side allows up to 399 feet of cable between the FrameSaver unit and the DTE.

399–533 – Equalization on the DSX-1 side allows up to 533 feet of cable between the FrameSaver unit and the DTE.

533–655 – Equalization on the DSX-1 side allows up to 655 feet of cable between the FrameSaver unit and the DTE.

Send All Ones on DSX-1 Failure

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether action is taken when a valid signal cannot be recovered for the DSX-1 (LOS, continuous OOF, or AIS).

Enable – Sends all ones on the DS0 channels allocated to the DSX-1 interface in the event of an LOS, AIS, or continuous OOS condition on the DSX-1 interface.

Disable – No action is taken when a signal fails on the DSX-1 interface. The data received is passed through the network interface channels unchanged.

Line Equalization

Page 76 of the Paradyne 9623 user manual — Table 3-20. ISDN BRI DBM Physical Interface Options (9126, 9626)
Page 76 · click to enlarge
Page 76

Configuring the ISDN DBM Interface (9126, 9128, 9626)

For models with ISDN backup capability, select Physical from the ISDN menu to configure the physical characteristics for DBM Interface.

Main Menu→Configuration→ISDN→Physical

When configuring a BRI DBM, refer to Table 3-20, ISDN BRI DBM Physical Interface Options (9126, 9626).

When configuring a PRI DBM, refer to Table 3-21, ISDN PRI DBM Physical Interface Options (9128).

Table 3-20. ISDN BRI DBM Physical Interface Options (9126, 9626)

Possible SettingsEnable, Disable Default Setting: Disable

Determines whether the ISDN interface is available for use.

Enable – The ISDN interface is enabled.

Disable – The ISDN interface cannot be configured, nor can it transmit or receive data. No PVC connections or frame relay DLCIs will be deleted. Disabling the ISDN interface results in the following:

All currently connected ISDN calls are terminated.

Alarms or traps associated with this interface are not generated or displayed.

Service Profile ID (SPID) 1 or 2

Possible Settings3 – 20 digits Default Setting: Clear

Specifies the SPID number assigned by the ISDN service provider for Bearer channel 1 (B1) and Bearer channel 2 (B2). SPID numbers are used by the switch to identify which ISDN services the DBM can access. All blanks is a valid setting.

3. 20 digits – You can enter a SPID number, or you can leave blanks. If a nondigit/ numeric is entered, an Invalid Character ( x ) message appears at the bottom of the screen. If fewer than three digits/numerics are entered, an Invalid – SPID must be at least 3 digits message appears at the bottom of the screen.

Clear – Clears the SPID field so it can be reentered.

Local Phone Number 1 or 2

Possible Settings10 digits Default Setting: Clear

Provides the telephone number associated with Bearer channel 1 (B1) and 2 (B2). All blanks is a valid setting.

10 digits – Enter the telephone number, up to 10 digits. If a nondigit/numeric is entered, an Invalid Character (x) message appears at the bottom of the screen.

Clear – Clears the phone number field so it can be reentered.

Interface Status

Page 77 of the Paradyne 9623 user manual — Table 3-21. ISDN PRI DBM Physical Interface Options (9128) (1 of 3)
Page 77 · click to enlarge
Page 77

Refer to the Table 3-21 when configuring a PRI DBM.

Table 3-21. ISDN PRI DBM Physical Interface Options (9128) (1 of 3)

Possible SettingsEnable, Disable Default Setting: Disable

Determines whether the ISDN interface is available for use.

Enable – The ISDN interface is enabled.

Disable – The ISDN interface cannot be configured, nor can it transmit or receive data. No PVC connections or frame relay DLCIs will be deleted. Disabling the ISDN interface results in the following:

All currently connected ISDN calls are terminated.

Alarms or traps associated with this interface are not generated or displayed.

LEDs associated with this interface are held in an “off" state. Specifically, the

DSX/PRI LEDs are held off if they represent the PRI status.

Possible SettingsNI-2, ATT_4ESS, ATT_5ESS Default Setting: NI-2

Specifies type of ISDN switch provided by the server.

NI-2 – The DBM will communicate with a service provider supporting the National ISDN-2 switching standard.

ATT_4ESS – The DBM will communicate with a service provider supporting the ATT 4ESS switching standard.

ATT_5ESS – The DBM will communicate with a service provider supporting the ATT 5ESS switching standard.

Possible Settings10 digits Default Setting: Clear

Provides the telephone number associated with all Bearer channels. All blanks is a valid setting.

10 digits – Where you enter the telephone number, up to 10 digits. If a nondigit/numeric is entered, an Invalid Character (x) message appears at the bottom of the screen.

Clear – Clears the phone number field so it can be reentered.

Possible SettingsD4, ESF Default Setting: ESF

Specifies the framing format for transmitted and received signals on the ISDN interface.

D4 – Uses D4 framing format.

ESF – Uses Extended Superframe framing format.

Show 4 more labels / short text on this page
Interface Status · Switch Type · Local Phone Number · Line Framing Format
Page 78 of the Paradyne 9623 user manual — Table 3-21. ISDN PRI DBM Physical Interface Options (9128) (2 of 3)
Page 78 · click to enlarge
Page 78

Table 3-21. ISDN PRI DBM Physical Interface Options (9128) (2 of 3)

Line Build Out (LBO)

Possible Settings0.0, –7.5, –15, –22.5 Default Setting: 0.0

Specifies the line build out for the signal transmitted to the ISDN.

0.0, –7.5, –15, –22.5 – Specifies line build out in dB.

Possible SettingsEnable, Disable Default Setting: Enable

Allows the initiation and termination of the line loopback (LLB) to be controlled by the receipt of LLB-Actuate and LLB-Release commands from the ISDN.

Enable – LLB is controlled by LLB-Actuate and LLB-Release commands. Receiving a LLB-Actuate command causes the system to enter a line loopback (provided an LLB can be performed in the system’s current state). Receiving an LLB-Release command terminates the LLB.

Disable – The system ignores the LLB-Actuate and LLB-Release commands.

Possible SettingsEnable, Disable Default Setting: Enable

Allows the initiation and termination of the payload loopback (PLB) to be controlled by the receipt of PLB-Actuate and PLB-Release commands from the ISDN.

Display Conditions – This option only appears when Line Framing Format is set to ESF.

Enable – PLB is controlled by PLB-Actuate and PLB-Release commands. Receiving a PLB-Actuate command causes the system to enter a payload loopback (provided a PLB can be performed in the system’s current state). Receiving a PLB-Release command terminates the PLB.

Disable – The system ignores the PLB-Actuate and PLB-Release commands.

ANSI Performance Report Messages

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether ANSI T1.403 compliance performance report messages (PRMs) are generated and sent to the ISDN over the ESF facility data link every second.

Display Conditions – This option only appears when Line Framing Format is set to ESF.

Enable – Generates and sends PRMs.

Disable – Does not generate and send PRMs.

Network Initiated LLB · Network Initiated PLB

Page 79 of the Paradyne 9623 user manual — Table 3-21. ISDN PRI DBM Physical Interface Options (9128) (3 of 3)
Page 79 · click to enlarge
Page 79

Table 3-21. ISDN PRI DBM Physical Interface Options (9128) (3 of 3)

Excessive Error Rate Threshold

Possible Settings10E-4, 10E-5, 10E-6, 10E-7, 10E-8, 10E-9 Default Setting: 10E-4

Sets the error rate threshold that determines when an EER condition is declared. The excessive error rate is determined by the ratio of the number of CRC6 errors to the total number of bits received over a set period of time.

Display Conditions – This option only appears when Line Framing Format is set to ESF.

10E-4 – Declares an EER if more than 1,535 CRC6 errors are detected in a 10 second period. Clears when fewer than 1,536 CRC6 errors are detected within the same time period.

10E-5 – Declares an EER if more than 921 CRC6 errors are detected in a 60 second period or a 10- 4 condition occurs. Clears when fewer than 922 CRC6 errors are detected within the same time period.

10E-6 – Declares an EER if more than 92 CRC6 errors are detected in a 60 second period or a 10- 5 or 10- 4 condition occurs. Clears when fewer than 93 CRC6 errors are detected within the same time period.

10E-7 – Declares an EER if more than 9 CRC6 errors are detected in a 60 second period or a 10- 6, or 10- 5, or 10- 4 condition occurs. Clears when fewer than 10 CRC6 errors are detected within the same time period.

10E-8 – Declares an EER if more than 41 CRC6 errors are detected in three 15 minute intervals or a 10-7, 10- 6, 10- 5, 10- 4 condition occurs. Clears when fewer than 42 CRC6 errors are detected within the same time period.

10E-9 – Declares an EER if more than 4 CRC6 errors are detected in three 15 minute intervals or a 10- 8, 10-7, 10- 6, 10- 5, or 10- 4 condition occurs. Clears when fewer than 5 CRC6 errors are detected within the same time period.

Possible SettingsASCII Text Entry , Clear Default Setting: blank

Identifies the transmission vendor’s circuit information to facilitate troubleshooting.

ASCII Text Entry – Assigns a name to identify the circuit (maximum 255 characters).

Clear – Removes the circuit identifier information.

Circuit Identifier

Page 80 of the Paradyne 9623 user manual — Table 3-22. ISDN Link Profile Options (1 of 3)
Page 80 · click to enlarge
Page 80

Setting Up ISDN Link Profiles (9126, 9128, 9626)

For models with ISDN backup capability, select ISDN Link Profiles from the ISDN menu to set up the ISDN Link Profiles (see Table 3-22, ISDN Link Profile Options).

Main Menu→Configuration→ISDN→ISDN Link Profiles

Table 3-22. ISDN Link Profile Options (1 of 3)

Possible Settings: ASCII Text Entry, HQ_Site Default Setting: HQ_Site for first link; blank for all others

Assigns the name to the ISDN link profile. It is generally the backup destination for a frame relay link. Each profile must have a unique link name. If the link name field is blank, the link profile will be deleted. Use ASCII text, 8 characters maximum.

ASCII Text Entry – Assigns a name to identify the ISDN link (maximum 255 characters).

HQ_Site – The link name configured in the remote site unit (originating a backup call) for the central site unit (answering a backup call). One link has a default value of HQ_Site to allow for Automatic Backup Configuration.

Possible SettingsAuto, Disable Default Setting: Auto

Determines whether the ISDN frame relay link is in or out of service.

Auto – The link is configured to be in service when needed. Packets will be transmitted and received on the interface, and the LMI for a PVC connection will become active when the link is required. If this profile is configured as the alternate link and the primary link or DLCI fails, the unit dials the Outbound Phone Number, or the Alternate Outbound Phone Number if the first call was unsuccessful. The unit also answers calls from Inbound Call IDs associated with this link. This link profile becomes active when:

This profile is configured as the alternate link and there is a failure of a primary link

or DLCI.

Source or Primary Destination DLCIs are configured on this link.

When the primary link recovers, the call is automatically disconnected.

Disable – The frame relay link is out of service. No data will be transmitted or received on the interface. If there is are any active calls when disabled, the calls are ended and no calls will be answered or originated using this profile.

Link Name · Link Status

Page 81 of the Paradyne 9623 user manual — NOTES:
Page 81 · click to enlarge
Page 81

Table 3-22. ISDN Link Profile Options (2 of 3)

Possible Settings: 0 – 9, *, #, space, _, –, (, or ) Default Setting: none

Specifies the primary phone number to call (the ISDN Called Party Identifier) for the Link Profile. Up to 18 valid characters can be entered. Each Outbound Phone Number must be unique. If not, the Outbound Phone Number is Not Unique message appears and you must enter another phone number.

Currently active calls are not effected when this number is changed.

Inbound Calling ID 1 or 2

Possible Settings0 – 9 Default Setting: none

Specifies the local phone number of a remote device from which that the unit will accept calls (the ISDN Calling Party Identifier). Up to 18 digits can be entered. Each Inbound Calling ID must be unique. If not, the Inbound Calling ID n is Not Unique message appears and you must enter another phone number.

For remote devices with a PRI DBM, only one Inbound Calling ID is required. Inbound Calling ID 2 is provided to identify incoming calls from a second phone number assigned to a remote device with a BRI DBM.

NOTES:

– Inbound Calling ID 2 is only useful when multiple local phone numbers are

programmed at the originating site (e.g., a 2B+D BRI location).

– For every originating (outbound) phone number entered, an answering (inbound)

phone number must be entered at the far end, and vice versa.

Currently active calls are not effected when this number is changed.

0. 9 – Specifies the numbers in the remote device’s local phone number.

Maximum Link Rate (Kbps)

Possible Settings:

For a BRI DBM64 , 128 For a PRI DBM: 64 – 1472
Default Setting64

Specifies the maximum rate that will be attempted for the frame relay link when it is activated. The actual rate achieved on the link depends upon the number of successful calls placed or answered, and the negotiated rate on each call.

64. An individual frame relay link is formed and a single call is placed using a B-channel when the link is activated.
128.. . 1472 – A constituent link is configured for each multiple of 64 Kbps in the specified bandwidth. This bundle of constituent links will function as a single frame relay multilink. When the multilink aggregate link is activated, calls will be placed or answered on as many constituent links as possible based upon available B-channels.

Outbound Phone Number

Page 82 of the Paradyne 9623 user manual — NOTE:
Page 82 · click to enlarge
Page 82

Table 3-22. ISDN Link Profile Options (3 of 3)

Possible SettingsCaller ID , Proprietary Default Setting: Caller ID

Specifies the method used to identify callers.

Caller ID – Incoming calls will only be answered and the frame relay link on this Link Profile will only be activated when the Caller ID received from the switch matches one of the configured Inbound Calling IDs.

Proprietary – Incoming calls will always be answered, even when no Caller ID is provided by the switch, provided the following conditions are met:

Link Status is set to Auto (the default).

At least one ISDN Link Profile is enabled.

When using the Proprietary method, the unit queries the originating unit for its Local Phone Number. If the returned phone number matches one of the configured Inbound Calling IDs, the call is accepted. If the queried unit does not respond with its phone number within five seconds, the unit drops the call.

Alternate Outbound Phone Number

Possible Settings: 0 – 9, *, #, space, _, –, (, or ) Default Setting: none

Specifies an alternate phone number to call (the ISDN Called Party Identifier) when a call using the primary Outbound Phone Number was unsuccessful. Up to 18 valid characters can be entered. Each Outbound Phone Number must be unique. If not, the Alt Outbound Phone Number is Not Unique message appears and you must enter another phone number.

Currently active calls are not effected when this number is changed.

Assigning Time Slots/Cross Connections

The Time Slot Assignment/Cross Connect feature provides an easy method of assigning time slots for frame relay data and creating cross-connections to the synchronous data interface. The system allows you to assign DS0s on the T1 network interface and between the user data port and network interface in order to share the T1 network.

You can also clear cross-connection assignments for the system, or for a selected slot or interface.

NOTE:

Although it is not required, it is suggested that you progress through each screen in order, from top to bottom.

Caller Identification Method

Page 83 of the Paradyne 9623 user manual — Value Meaning
Page 83 · click to enlarge
Page 83

Assigning Time Slots to the Network Interface

Before assigning network time slots for use by frame relay traffic, configure the Network physical and Frame Relay options (if needed), then allow Time Slot Discovery to autodetect and assign the appropriate time slots to frame relay.

If there are multiple Frame Relay data links on the network interface, or if Time Slot Discovery is not currently active, you can manually assign time slots on the network interface for frame relay traffic using the Frame Relay Network Assignments screen. This screen is read-only when Time Slot Discovery is set to Enable for the network interface.

Link Layer Network Time Slot Assignment Screen Example

main/config/tslot_assign/frame_relay 9128-II Device Name: Node A 11/05/2002 13:03

LINK LAYER NETWORK 1 ASSIGNMENT Time Slot Discovery: Disable

N01 N02 N03 N04 N05 N06 N07 N08 Available

N09 N10 N11 N12 N13 N14 N15 N16 Available Available FrameRly1

N17 N18 N19 N20 N21 N22 N23 N24 FrameRly1

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Save PgDn PgUp ClearAll DSXAssign

Value Meaning

Specifies whether the time slots used for frame relay traffic should be discovered from the network interface upon detection of an LMI failure. This option allows additional time slots to be added without manually reconfiguring the device.

Ntt This field represents time slot tt of the selected network interface.

Assigned The time slot is already assigned to something other than frame relay, so it is unavailable. Assigned time slots cannot be modified from this screen.

Available The time slot is currently unassigned.

FrameRly1 The time slot is assigned to frame relay service, link 1.

FrameRly2 The time slot is assigned to frame relay service, link 2.

PPP The time slot is assigned to the network interface.

Time Slot Discovery

Page 84 of the Paradyne 9623 user manual — Value Meaning
Page 84 · click to enlarge
Page 84

For easy movement between screens, select the DSXAssign function key to go directly to the DSX-1 to Network Assignments screen.

Time Slot Assignment Rule:

Valid network time slots are either Available or contain a Frame Relay Link 1 assignment.

Procedure

1. Follow this menu selection sequence:

Main Menu→Configuration→Time Slot Assignment → Link Layer Network Assignments

The Frame Relay Network Assignments screen appears. This screen contains a matrix of the current assignment status of all time slots on the network interface.

2. Enable or disable Time Slot Discovery.

— When enabled, the unit examines all time slots not cross-connected to other ports to determine which time slots are being used by the network for frame relay traffic. These time slots are set to FrameRly1. This is the factory default.

— When disabled, time slot assignments must be manually configured.

3. If Time Slot Discovery is disabled, assign network time slots for use by frame relay service, link 1, by typing FrameRly1 in the selected Network field.
4. Repeat Step 3 until all desired time slots are assigned.
5. Save the configuration.

Assigning DSX-1 Time Slots to the Network Interface

DSX-1 time slots are assigned by channel allocation, where you specify individual time slots. The DSX-1 interface must be enabled to assign DSX-1 time slots to the network interface (see Table 3-19, DSX-1 Physical Interface Options).

Value Meaning

Ntt It represents time slot tt of the selected network interface.

Assigned The time slot is already assigned to something other than a DSX-1 time slot, so it is unavailable. Assigned time slots cannot be modified from this screen.

Available The time slot is currently unassigned.

DSX-1/tt Slot tt of the DSX-1 interface is assigned to the network interface time slot identified right above it (Ntt).

Page 85 of the Paradyne 9623 user manual — Time Slot Assignment Rules:
Page 85 · click to enlarge
Page 85

DSX-1 to Network Time Slot Assignment Screen Example (Page 1)

main/config/tslot_assign/dsx 9128-II Device Name: Node A 5/26/1999 23:32

DSX-1 TO NETWORK 1 ASSIGNMENTS Page 1 of 2

N01 N02 N03 N04 N05 N06 N07 N08 DSX-1/01 DSX-1/02 DSX-1/03 DSX-1/04 Assigned

N09 N10 N11 N12 N13 N14 N15 N16 DSX-1/09 DSX-1/01 Available

N17 N18 N19 N20 N21 N22 N23 N24 Available

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Save PgDn PgUp ClearAll FrAssign

Page 2 of 2 is for defining signaling assignments and trunk conditioning for each DSX-1 interface time slot. See DSX-1 Signaling Assignments and Trunk Conditioning (Page 2) on page 3-54 for an example of this screen.

For easy movement between screens, select the FrAssign function key to go directly to the Frame Relay Network Assignments screen.

Time Slot Assignment Rules:

Valid Network time slots are either Available or contain a DSX-1 time slot assignment.

Valid DSX-1 time slots are those that are unassigned, including the currently assigned time slot.

Order of display is as follows:

— Available is the first selection.

— Then, from the lowest DSX-1 interface to the highest DSX-1 interface.

— Then the lowest available time slot number to the highest available time slot number.

For example, if the cursor is on a field with the Available value under assigned time slot Ntt, pressing the Spacebar causes this field’s values to cycle through all valid DSX-1 time slots, starting with Ds-p/yy, assuming it is unassigned. If Ds-p/tt is already assigned, the next valid time slot in the order described above is displayed.

Page 86 of the Paradyne 9623 user manual — DSX-1 to Network Time Slot Assignment Screen Example (Page 2)
Page 86 · click to enlarge
Page 86

Procedure

1. Follow this menu selection sequence:

Configuration→Time Slot Assignment→DSX-to-Network Assignments

The DSX-1 to Network Assignments screen appears. This screen contains a matrix of the current cross-connect status of all time slots on the network interface.

2. Move the cursor to the next time slot that can be edited (underlined). Use the spacebar or type in the desired time slot to display its time slot assignment.
3. Repeat Step 2 until all desired time slots are assigned.
4. Save the configuration.

DSX-1 Signaling Assignments and Trunk Conditioning (Page 2)

The second page of the DSX-1 to Network Assignments screen allows you to define the signaling assignments and trunk conditioning for each time slot on the DSX-1 interface. You can specify whether robbed bit signaling information is being passed within a given DS0, and the value of the signaling bits that will be transmitted for that DS0 to the other cross-connected T1 network interface if a Carrier Group Alarm (CGA) occurs on a T1 network interface.

DSX-1 to Network Time Slot Assignment Screen Example (Page 2)

main/config/tslot_assign/dsx 9128-II Device Name: Node A 5/26/2000 23:32

DSX-1 TO NETWORK 1 ASSIGNMENTS Page 2 of 2 SIGNALING AND TRUNK CONDITIONING

Network 1 Side DSX-1 Side Network 1 Side DSX-1 Side

Net1/01 E&M-busy - DSX-1/01 E&M-busy Net1/02 E&M-busy - DSX-1/01 E&M-busy Net1/03 E&M-busy - DSX-1/03 E&M-busy Net1/04 E&M-busy - DSX-1/04 E&M-busy Net1/09 None - DSX-1/09 None Net1/10 None - DSX-1/10 None

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Save PgDn PgUp ClearAll VocAssign FrAssign

For easy movement between screens, select the FrAssign function key to go directly to the Frame Relay Network Assignments screen or the DSXAssign function key to go to the DSX-1 to Network Assignments screen.

Page 87 of the Paradyne 9623 user manual — RBS
Page 87 · click to enlarge
Page 87

Only those DSX-1-to-Network assignments from page 1 are displayed on this page, from left to right and top to bottom in ascending order, by network and time slot.

When a CGA condition (LOS, OOF, or AIS) is declared for a T1 interface, the signaling bits being transmitted to the other T1 interface for the DS0 are forced to idle for two seconds (except for user-defined patterns which are transmitted immediately). This drops any call in progress. The signaling bits are then forced to the selected state (Busy or Idle), and remain in this state until the CGA condition clears. At this point, the received signaling bits from the T1 interface which formerly had the CGA condition are passed through to the other T1 interface.

NOTE:

Trunk conditioning will only occur on DS0s that are cross-connected to another T1 interface. All other DS0s remain unaffected by trunk conditioning.

Enter one of the values shown in Table 3-23, Signaling and Trunk Conditioning Values, in each of the fields on both the Network side and the DSX-1 side. Although you can choose any value for the DSX-1 side, the default value displayed is based on a typical setting that would be used with the corresponding Network side value. Typical pairs of values are shown in the table below. If you change the Network side value, the DSX side value is changed to the corresponding default value.

Table 3-23. Signaling and Trunk Conditioning Values (1 of 3)

Network Side Meanings DSX-1 Side

None No signaling used on this DS0. Use this setting if there is no voice signaling information being passed on this DS0 (clear channel).

RBS (default) Robbed Bit Signaling is used on this DS0, but no trunk conditioning. Signaling bits will be passed to the T1 interface to which this DS0 is cross-connected when this T1 interface is not in CGA, but the signaling bits will be all ones when CGA is present.

RBS

The following values configure the cross-connect for RBS, as well as perform the trunk conditioning. Although ABCD signaling bits for each setting are described, only AB bits are transmitted when the cross-connected T1 network interface is using D4 framing.

None

Page 88 of the Paradyne 9623 user manual — Table 3-23. Signaling and Trunk Conditioning Values (2 of 3)
Page 88 · click to enlarge
Page 88

Table 3-23. Signaling and Trunk Conditioning Values (2 of 3)

Network Side Meanings DSX-1 Side

E&M-idle The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the idle state for an E&M interface (ABCD = 0000).

E&M-busy The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the busy state for an E&M interface (ABCD = 1111).

FXOg-idle The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the idle state for an FXO Ground-Start interface (ABCD = 1111).

FXOg-busy The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the busy state for an FXO Ground-Start interface (ABCD = 0101).

FXOl-idle The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the idle state for an FXO Loop-Start interface (ABCD = 0101).

FXOl-busy The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the busy state for an FXO Loop-Start interface (ABCD = 0101).

FXSg-idle The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the idle state for an FXS Ground-Start interface (ABCD = 0101).

FXSg-busy The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the busy state for an FXS Ground-Start interface (ABCD = 1111).

FXSl-idle The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the idle state for an FXS Loop-Start interface (ABCD = 0101).

FXSl-busy The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the busy state for an FXS Loop-Start interface (ABCD = 1111).

FXOD-idle The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the idle state for an FXODN interface (ABCD = 0000).

FXOD-busy The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the busy state for an FXODN interface (ABCD = 1111).

FXSD-idle The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the idle state for an FXSDN interface (ABCD = 0000).

FXSD-busy The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the busy state for an FXSDN interface (ABCD = 1111).

Show 14 more labels / short text on this page
E&M idle · E&M busy · FXSg-idle · FXSg-busy · FXSl-idle · FXSl-busy · FXOg-idle · FXOg-busy · FXOl-idle · FXOl-busy · FXSD-idle · FXSD-busy · FXOD-idle · FXOD-busy
Page 89 of the Paradyne 9623 user manual — Table 3-23. Signaling and Trunk Conditioning Values (3 of 3)
Page 89 · click to enlarge
Page 89

Table 3-23. Signaling and Trunk Conditioning Values (3 of 3)

Network Side Meanings DSX-1 Side

PLAR3idle The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the idle state for a PLAR D3 interface (ABCD = 0000).

PLAR3busy The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the busy state for an PLAR D3 interface (ABCD = 1111).

PLAR4idle The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the idle state for a PLAR D4 interface (ABCD = 1111).

PLAR4busy The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the busy state for an PLAR D4 interface (ABCD = 0000).

DPO-idle The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the idle state for a DPO interface (ABCD = 0000).

DPO-busy The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the busy state for a DPO interface (ABCD = 1111).

DPT-idle The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the idle state for a DPT interface (ABCD = 0000).

DPT-busy The signaling bits transmitted to the cross-connected T1 interface during a CGA represent the busy state for a DPT interface (ABCD = 1111).

USER-xxxx The signaling bits transmitted to the cross-connected T1 interface during a CGA represent a user-defined pattern of ABCD = xxxx.

* xxxx is the same value on both the Network and the DSX-1 sides.

Show 9 more labels / short text on this page
PLAR3idle · PLAR3busy · PLAR4idle · PLAR4busy · DPT-idle · DPT-busy · DPO-idle · DPO-busy · USER-xxxx*
Page 90 of the Paradyne 9623 user manual — Value Meaning
Page 90 · click to enlarge
Page 90

Assigning a Synchronous Data Port to Network or DSX-1 Time Slots

For a FrameSaver SLV unit with two data ports, another assignment screen is available. Use the Sync Data Port Assignment screen to view the status of:

All DS0 assignments on the Network interface

All DS0 assignments on the DSX-1 interface

Then, you can a assign synchronous data port to:

Network interface time slots

DSX-1 interface time slots

Synchronous Data Port Assignment Screen Example

main/config/tslot_assign/sync_data/net 9128-II Device Name: Node A 5/26/2000 23:32

SYNC DATA PORT ASSIGNMENT

Assign ToNet1

N01 N02 N03 N04 N05 N06 N07 N08 Assigned Port-2 Port-1 Assigned

N09 N10 N11 N12 N13 N14 N15 N16 Assigned Port-2 Port-1 Available

N17 N18 N19 N20 N21 N22 N23 N24 Available

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Save ClearAll DSXAssign FrAssign

Value Meaning

Assign To Specifies either Net1 (network) or DSX1-1 (DSX-1) time slots.

This field represents time slot tt of the network interface.

This field represents time slot tt of the DSX-1 interface.

Assigned The time slot is already assigned to a network or DSX-1 time slot. Assigned time slots cannot be modified from this screen.

Available The time slot is currently unassigned.

Port-2 For a FrameSaver SLV unit with two data ports, synchronous data Port-2 is assigned to the time slot.

Ntt · Dtt

Page 91 of the Paradyne 9623 user manual — Clearing Assignments
Page 91 · click to enlarge
Page 91

For easy movement between screens, select the FrAssign function key to go directly to the Frame Relay Network Assignments screen or the DSXAssign function key to go to the DSX-1 to Network Assignments screen.

Time Slot Assignment Rules:

To assign a synchronous data port to network or DSX-1 time slots, Port-2’s Port Use option must be set for Synchronous Data (see Table 3-15, V.35 Data Port Physical Interface Options).

If the DSX-1 interface is disabled, only Net1 is available for synchronous data port assignment (see the Interface Status option in Table 3-19, DSX-1 Physical Interface Options).

Procedure

1. Select one of the following menu selection sequences:

Main Menu→Configuration→Time Slot Assignment → Sync Data Port Assignments or

Main Menu→Easy Install→Time Slot Assignment Screen

2. Select an interface in the Assign To field. A matrix of the current cross-connect status of all time slots on the selected interface appears.
3. Move the cursor to the next time slot that can be edited (underlined). Use the spacebar or type in the desired time slot to display its time slot assignment.
4. Repeat Step 3 until the synchronous data port is assigned to all desired time slots.
5. Save the configuration.

Clearing Assignments

Clearing assignments sets all time slots to Unassgn (unassigned).

Main Menu→Configuration→Time Slot Assignment→Clear Assignments

Page 92 of the Paradyne 9623 user manual — Table 3-24. Interface Frame Relay Options (1 of 3)
Page 92 · click to enlarge
Page 92

Configuring Frame Relay for an Interface

Select Frame Relay from the interface’s menu to display or change the Frame Relay options for an individual interface (see Table 3-25, Interface PPP Options). Frame Relay is not an option on the Network menu unless Service Type is Frame Relay.

Main Menu→Configuration→[Network/Data/T3 User Ports] →Frame Relay

See Configuring PPP for an Interface on page 3-63, for additional information.

Table 3-24. Interface Frame Relay Options (1 of 3)

Possible SettingsInitialize_From_Net1FR1 , Initialize_From_Interface, Auto_On_LMI_Fail, Standard, Annex-A, Annex-D

Default Setting:

For a user data port link: Initialize_From_Interface For a network link: Auto_On_LMI_Fail

Specifies either the LMI protocol supported on the frame relay interface or the discovery source for the LMI protocol.

Initialize_From_Net1FR1 – The LMI type supported on this frame relay link will be configured to match the LMI protocol initially discovered on the primary Network frame relay link (Net1FR1). LMI Protocol is set to None internally, but once a protocol has become active or is set on the primary Network link, the protocol will be set to the same value on this link (Standard, Annex-A or Annex-D). The protocol will not be updated based on changes to Net1FR1 after being set initially.

Display Conditions – This option value only appears for a user data port.

Initialize_From_Interface – The LMI type supported on this frame relay link will be configured to match the LMI protocol discovered from the attached Network line or DTE device. Once a protocol has become active, the protocol will be set to the protocol discovered (Standard, Annex-A or Annex-D) on the frame relay link. The protocol will not be updated after being initially discovered. Frame relay links on user data ports discover the LMI protocol from an attached device via LMI status polls. Frame relay links on the network interface discover LMI protocol by sending polls to an attached Network line and “listening” for correct poll response messages.

Auto_On_LMI_Fail – The LMI type supported on this frame relay link will be configured to match the LMI protocol discovered from the attached Network line or the DTE device whenever an LMI Link Down failure occurs. This option is available for frame relay links on the Port and network interfaces. Frame relay links on user data ports discover the LMI protocol from LMI status polls by attached DTE devices. Frame relay links on the network interface discover LMI protocol by sending polls to an attached Network line and “listening” for correct poll response messages.

Standard – Supports Standard LMI and the Stratacom enhancements to the Standard LMI.

Annex-A – Supports LMI as specified by Q.933, Annex A.

Annex-D – Supports LMI as specified by ANSI T1.617, Annex D.

LMI Protocol

Page 93 of the Paradyne 9623 user manual — Table 3-24. Interface Frame Relay Options (2 of 3)
Page 93 · click to enlarge
Page 93

Table 3-24. Interface Frame Relay Options (2 of 3)

Possible SettingsEnable, Disable Default Setting: Disable

Determines whether or not CIR (Committed Information Rate) and EIR (Excess Information Rate) will be enforced by the unit on frames being sent on network frame relay links.

Enable – CIR and EIR are enforced.

Frames that exceed CIR will be marked Discard Eligible (DE). These frames are

counted in the Above CIR but within EIR category until this category is full. Once full, additional frames are counted as being in the Within CIR category.

Frames in excess of EIR will be discarded.

For CSU/DSUs only, DE frames received from the external router are credited as

frames transmitted above CIR. They are credited as frames transmitted between CIR and EIR until that count reaches its limit, at which point they are counted as frames transmitted above EIR.

Disable – CIR and EIR are not enforced.

Possible SettingsSystem , Custom Default Setting: System

Allows you to use the system LMI options, or to set specific LMI options for this interface.

System – Use system LMI options (see Table 3-1, System Frame Relay and LMI Options).

Custom – Use the following options in this table to configure LMI parameters.

Frame Relay DS0s Base Rate

Possible SettingsNx64 , Nx56 Default Setting: Nx64

Selects the base rate for the DS0s allocated to frame relay on the network interface.

Nx64 – The base rate is 64 Kbps.

Nx56 – The base rate is 56 Kbps.

LMI Error Event (N2)

Possible Settings1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Default Setting: 3

Configures the LMI-defined N2 parameter, which sets the number of errors that can occur on the LMI link before an error is reported. Applies to both the user and network sides of a UNI.

1. 10 – Specifies the maximum number of errors.

Traffic Policing · LMI Parameters

Page 94 of the Paradyne 9623 user manual — Table 3-24. Interface Frame Relay Options (3 of 3)
Page 94 · click to enlarge
Page 94

Table 3-24. Interface Frame Relay Options (3 of 3)

LMI Clearing Event (N3)

Possible Settings1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Default Setting: 1

Configures the LMI-defined N3 parameter, which sets the number of error-free messages that must be received before clearing an error event. Applies to both the user and network sides of a UNI.

1. 10 – Specifies how many error-free messages it will take to clear the error event.

LMI Status Enquiry (N1)

Possible Settings1, 2, 3, 4, . . . 255 Default Setting: 6

Configures the LMI-defined N1 parameter, which sets the number of status enquiry polling cycles that the user side of the LMI initiates before a full status enquiry is initiated. Applies to the user side of a UNI only.

1. 255 – Specifies the number of status enquiry polling cycles that can be initiated before a full status enquiry is initiated.
Possible Settings5, 10, 15, 20, 25, 30 Default Setting: 10

Configures the LMI-defined T1 parameter, which sets the number of seconds between the initiation of status enquiry messages on the user side of the LMI. Applies to the user side of a UNI only.

5. 30 – Specifies the number of seconds between the initiation of status enquiry messages in increments of 5.

LMI Inbound Heartbeat (T2)

Possible Settings5, 10, 15, 20, 25, 30 Default Setting: 15

Configures the LMI-defined T2 parameter, which sets the number of seconds between the receipt of status enquiry messages on the network side of the LMI. Applies to the network side of a UNI only.

5. 30 – Specifies the number of seconds between the receipt of status enquiry messages in increments of 5.

LMI N4 Measurement Period (T3)

Possible Settings5, 10, 15, 20, 25, 30 Default Setting: 20

Configures the LMI-defined T3 parameter, which is the time interval (in seconds) that the network side of the LMI uses to measure the maximum number of status enquiry messages that have been received (N4) from the user side.

5. 30 – Specifies the interval of time in increments of 5.

LMI Heartbeat (T1)

Page 95 of the Paradyne 9623 user manual — Table 3-25. Interface PPP Options
Page 95 · click to enlarge
Page 95

Configuring PPP for an Interface

Select PPP from the interface’s menu to display or change the PPP options for an individual interface (see Table 3-25, Interface PPP Options). PPP is not an option on the Network or Data Ports menus unless Service Type is PPP.

Main Menu→Configuration→[Network/Data Ports] →PPP

Table 3-25. Interface PPP Options

Possible SettingsStandard, IP Enabled

Default Setting:

For a user data port link: Standard For a network link: IP Enabled

Specifies the type of PPP circuit configured on the interface.

Standard – The circuit operates normally, supporting neither Payload Management nor IP Enabled characteristics. This option value only appears for a user data port.

IP Enabled – The circuit is IP Enabled. This option is read-only for the network interface.

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether Link Control Protocol (LCP) echo requests are generated on the circuit.

Enable – LCP Echo-Request codes are generated on the circuit, and Echo-Reply codes are generated for Echo-Requests received from the remote end.

Disable – LCP Echo-Request codes are not generated on the circuit, but Echo-Reply codes are generated for Echo-Requests received from the remote end.

Possible SettingsNx64 , Nx56 Default Setting: Nx64

Selects the base rate for the DS0s allocated to PPP on the network interface.

Display Conditions – This option appears only for network interfaces that support DS0s.

Nx64 – The base rate is 64 Kbps.

Nx56 – The base rate is 56 Kbps.

Circuit Type · Keep Alive · DS0 Base Rate

Page 96 of the Paradyne 9623 user manual — Table 3-26. DLCI Record Options (1 of 4)
Page 96 · click to enlarge
Page 96

Manually Configuring DLCI Records

The Auto-Configuration feature automatically configures DLCI Records and their PVC Connections. DLCI Records can also be created manually (see Table 3-26, DLCI Record Options).

Main Menu →Configuration →[Network/Data Port/ISDN/Virtual Router Ports] →DLCI Records

Available paths to DLCI Records Options depend on the Service Type and FrameSaver model:

DLCI Records is not an option on the Network menu unless Service Type is Frame Relay

Data Port is available only on CSU/DSUs

ISDN is available only when the FrameSaver unit has an ISDN DBM installed

Virtual Router Ports is available only on the FrameSaver SLV Router

Typically, DLCI Records only need to be configured when building Management PVCs between the NOC and the central site unit; the unit automatically configures non-management DLCI Records and PVC Connections.

Table 3-26. DLCI Record Options (1 of 4)

Possible Settings: 16 – 1007 Default Setting: Initially blank; no default.

Specifies the number for the DLCI in the DLCI record. The parameter determines which DLCI record is used for transferring data on a particular frame relay interface. DLCI numbers range from 0to1023. However, the numbers 0 – 15 and 1008 – 1023 are reserved. Entry of an invalid number results in the error message Value Out of Range (16–1007). If the DLCI number is part of a connection, this field is read-only.

– The DLCI number entered must be unique for the interface. – Changing settings for this configuration option causes the FrameSaver unit to abort

any active frame relay tests.

16. 1007 – Specifies the DLCI number (inclusive).

DLCI Number

Page 97 of the Paradyne 9623 user manual — Table 3-26. DLCI Record Options (2 of 4)
Page 97 · click to enlarge
Page 97

Table 3-26. DLCI Record Options (2 of 4)

Possible SettingsStandard, Multiplexed, IP Enabled Default Setting:
For user data port DLCIsStandard For network interface DLCIs: Multiplexed

Specifies whether the DLCI is standard or multiplexed. This field is read-only when the selected DLCI is used in a PVC or Management link connection and the DLCI Type is Standard.

Display Conditions – This option does not appear for a user data port or a virtual router port, and it cannot be changed if the DLCI is specified as the TS Access Management Link.

Standard – Supports standard DLCIs as specified by the Frame Relay Standards. Use this setting when a non-FrameSaver unit is at the other end.

Multiplexed – Enables multiplexing of multiple connections into a single DLCI. Allows a single PVC through the frame relay network to carry multiple DLCIs as long as these connections are between the same two endpoints (proprietary). Do not select Multiplexed unless there are FrameSaver units at both ends of the connection.

IP Enabled – Enables connection to one or more endpoints through a Layer 3 network. A Payload Management PVC is created as well as the IP Enabled DLCI.

Possible Settings:

For 9123, 9126, 9128: 0 – 1536000 For 9520, 9520-ILM: 0 – 44210000 For 9623, 9626: 0 – 64000 For 9820-2M: 0 – 2048000 For 9820-8M: 0 – 8192000 For 9820-45M: 0 – 44210000

Default Setting0

Determines the data rate for the DLCI that the network commits to accept and carry without discarding frames; the CIR in bits per second. Entry of an invalid rate causes the error message Value Out of Range (0 – x), where x = the maximum line rate available on the port.

0. maximum – Specifies the network-committed data rate.
Possible Settings1 – 65535 Default Setting: Read Only

Displays the DLCI’s calculated value of its committed rate measurement interval (Tc) in milliseconds. This value is calculated based upon the settings for the Committed Burst Size Bc (Bits) and CIR (bps) options.

DLCI Type · CIR (bps) · Tc

Page 98 of the Paradyne 9623 user manual — Table 3-26. DLCI Record Options (3 of 4)
Page 98 · click to enlarge
Page 98

Table 3-26. DLCI Record Options (3 of 4)

Committed Burst Size Bc (Bits)

Possible SettingsCIR, Other Default Setting: CIR

Specifies whether the DLCI’s committed burst size will follow the CIR, or whether it will be entered independently. This value is the maximum amount of data that the service provider has agreed to accept during the committed rate measurement interval (Tc).

CIR – Uses the value in the CIR (bps) option as the committed burst size (Bc). The Bc and excess burst size (Be) options are updated when a CIR update is received from the network switch.

Other – Allows you to specify the committed burst size for the DLCI. When Other is selected, the Bc and Be values must be manually entered and maintained, as well.

Possible Settings:

For 9123, 9126, 9128: 0 – 1536000 For 9520, 9520-ILM: 0 – 44210000 For 9623, 9626: 0 – 64000 For 9820-2M: 0 – 2048000 For 9820-8M: 0 – 8192000 For 9820-45M: 0 – 44210000

Default Setting0

Allows you to display or change the DLCI’s committed burst size.

Display Conditions – This option only appears when Committed Burst Size is set to Other.

0. maximum – Specifies the DLCI’s committed burst size.

Excess Burst Size (Bits)

Specifies the maximum amount of data in bits that the network may accept beyond the CIR without discarding frames.

Possible Settings:

For 9123, 9126, 9128: 0 – 1536000 For 9520, 9520-ILM: 0 – 44210000 For 9623, 9626: 0 – 64000 For 9820-2M: 0 – 2048000 For 9820-8M: 0 – 8192000 For 9820-45M: 0 – 44210000

Default Setting[Maximum]

Allows you to display or change the DLCI’s excess burst size.

0. maximum – Specifies the DLCI’s excess burst size.

Bc · Be

Page 99 of the Paradyne 9623 user manual — Table 3-26. DLCI Record Options (4 of 4)
Page 99 · click to enlarge
Page 99

Table 3-26. DLCI Record Options (4 of 4)

Possible SettingsLow, Medium, High Default Setting: High

Specifies the relative priority for data received on the DLCI from an attached device (also known as quality of service). All data on Port 1 is cut-through, as long as there is no higher-priority data queued from another user port. The DLCI priority set for an interface applies to data coming into that interface. For example, the priority set for DLCIs on Port 1 applies to data coming into Port 1 from the attached equipment (such as a router).

Display Conditions – This option is not available for the network interface or, if the model has ISDN backup capability, an ISDN DBM interface.

Low – Data configured for the DLCI has low priority.

Medium – Data configured for the DLCI has medium priority.

High – Data configured for the DLCI has high priority.

Possible SettingsLow, Medium, High Default Setting: Medium

Specifies the relative priority for management traffic sent on management PVCs on this DLCI to the network.

Display Conditions – This option is not available on a user data port or a virtual router port.

Low – Management data configured for the DLCI has low priority.

Medium – Management data configured for the DLCI has medium priority.

High – Management data configured for the DLCI has high priority.

Possible SettingsA, B, C, . . . Z, None Default Setting: None

Assigns DLCIs to a backup group so backup does not take place unless all DLCIs in the group are no longer operational or latency has been exceeded. Backup is terminated when one DLCI in the group is operational again. This feature reduces backup charges when redundant PVCs have been configured.

Display Conditions – This option is not available on a user data port, a virtual router port, or an ISDN DBM interface.

A – Z – Specifies the designation for this group of DLCIs. Only DLCIs in a PVC will be considered part of a Backup Group.

None – No Backup Groups have been set up.

DLCI Priority · Outbound Management Priority · Backup Group

Page 100 of the Paradyne 9623 user manual — NOTES:
Page 100 · click to enlarge
Page 100

Configuring Circuit Records for the Network Interface

For Models 9783 and 9788, circuit records can be created or modified and PVCs can be created based on existing DLCIs using the Network Circuit Records screen.

Main Menu →Configuration →Network →Circuit Records

If any DLCI records exist, you may enter a DLCI number at the bottom of the screen to display, copy from, or modify a DLCI record.

Select CreatePVC to create a new PVC based on an existing DLCI record.

Table 3-27. Circuit Records Options (1 of 3)

Possible Settings16 – 1007 Default Setting: Initially blank

Specifies the number for the DLCI in the DLCI record. The parameter determines which DLCI record is used for transferring data on a particular frame relay interface. DLCI numbers range from 0–1023 with numbers 0–15 and 1008–1023 reserved. Entry of an invalid number results in the error message Value Out of Range (16–1007). If the DLCI number is part of a connection, this field is read-only.

NOTES:

– If a DLCI number is not entered, the DLCI record is not created. – The DLCI number entered must be unique for the interface.

– Changing this setting causes the FrameSaver unit to abort any active frame relay

tests.

16. 1007 – Specifies the DLCI number.

Possible Settings:

– For the VPI0 – 15
– For the VCI32 – 255
Default SettingInitially blank

Specifies the VPI and VCI. Entry of an invalid number results in the error message Value Out of Range (0 – 15) for the VPI, and Value Out of Range (32 – 255) for the VCI. The VPI/VCI must be unique on the ATM link.

0. 15 – Specifies the VPI.
32. 255 – Specifies the VCI.

DLCI Number · VPI,VCI Number

Page 101 of the Paradyne 9623 user manual — Table 3-27. Circuit Records Options (2 of 3)
Page 101 · click to enlarge
Page 101

Table 3-27. Circuit Records Options (2 of 3)

Possible SettingsStandard, Multiplexed, IP Enabled Default Setting: Multiplexed

Specifies whether the DLCI is standard, multiplexed, or IP Enabled. This field is read-only when the selected DLCI is used in a PVC or Management link connection and the DLCI Type is Standard.

Display Conditions – This option cannot be changed if the DLCI is specified as the TS Access Management Link. It is not applicable when FRF.8 Encapsulation Mode is set to Translational (see Table 3-28, Network ATM Options).

Standard – Supports standard DLCIs as specified by the Frame Relay Standards. Use this setting when a non-FrameSaver unit is at the other end.

Multiplexed – Enables multiplexing of multiple connections into a single DLCI. Allows a single PVC through the frame relay network to carry multiple DLCIs as long as these connections are between the same two endpoints (proprietary). Do not select Multiplexed unless there are FrameSaver units at both ends of the connection.

IP Enabled – Enables connection to one or more endpoints through a Layer 3 network. A Payload Management PVC is created as well as the IP Enabled DLCI.

Possible Settings:

– 97830 – 2320000 – 9788: 0 – 2312000
Default Setting0

Determines the data rate in bits per second for the DLCI that the network commits to accept and carry without discarding frames. Entry of an invalid rate causes the error message Value Out of Range (0 – x), where x is the maximum line rate available on the port.

0. maximum – Specifies the network-committed data rate.
Possible Settings1 – 65535 Default Setting: Read-Only

Displays the DLCI’s calculated value of its committed rate measurement interval (Tc) in milliseconds based on the CIR (bps) and Committed Burst Size Bc (Bits) settings.

Committed Burst Size Bc (Bits)

Possible SettingsCIR, Other Default Setting: CIR

Specifies whether the DLCI’s committed burst size uses the CIR setting or is entered independently. This value is the maximum amount of data that the service provider has agreed to accept during the committed rate measurement interval (Tc).

CIR – Uses the value in the CIR (bps) option as the committed burst size (Bc). The Bc and excess burst size (Be) options are updated when a CIR update is received from the network switch.

Other – Allows you to specify the committed burst size for the DLCI. When Other is selected, the Bc and Be values must be manually entered and maintained.

DLCI Type · CIR (bps) · Tc

Page 102 of the Paradyne 9623 user manual — Table 3-27. Circuit Records Options (3 of 3)
Page 102 · click to enlarge
Page 102

Table 3-27. Circuit Records Options (3 of 3)

Possible Settings:

– 97830 – 2320000 – 9788: 0 – 2312000
Default Setting0

Allows you to display or change the DLCI’s committed burst size.

Display Conditions – This option appears only when Committed Burst Size is set to Other.

0. maximum – Specifies the DLCI’s committed burst size.

Excess Burst Size Be (Bits)

Possible Settings:

– 97830 – 2320000 – 9788: 0 – 2312000

Default Setting:

– 97832320000
– 97882312000

Specifies the maximum amount of data in bits that the network may accept beyond the CIR without discarding frames.

Display Conditions – This option appears only when Committed Burst Size is set to Other.

0. maximum – Specifies the DLCI’s committed burst size.
Possible SettingsLow, Medium, High Default Setting: Medium

Specifies the relative priority for management traffic sent on management PVCs on this DLCI to the network.

Low – Management data configured for the DLCI has low priority.

Medium – Management data configured for the DLCI has medium priority.

High – Management data configured for the DLCI has high priority.

Bc · Outbound Management Priority

Page 103 of the Paradyne 9623 user manual — ILMI
Page 103 · click to enlarge
Page 103

Configuring ATM for the Network Interface

For Models 9783 and 9788, select ATM from the Network menu to display or change ATM option settings (see Table 3-28, Network ATM Options).

Main Menu→Configuration→Network →ATM

Table 3-28. Network ATM Options

Possible SettingsEnable, Disable

Default Setting:

– 9783 – If DSLAM Type is set to Paradyne: Enable

– 9783 – If DSLAM Type is set to a non-Paradyne DSLAM: Disable – 9788: Enable

Specifies whether the 48-byte information field of ATM cells is scrambled/descrambled per ANSI T1.646 on this ATM link.

Enable – Activates scrambling/descrambling of transmitted or received ATM cells.

Disable – No scrambling/descrambling is performed.

Cell Delineation Error Event Threshold

Possible Settings1 – 1000 Default Setting: 10

Specifies the number of OCD (Out of Cell Delineation) events that must occur in a one-minute interval for an LCD (Loss of Cell Delineation) alarm to be declared.

1. 1000 – Specifies the LCD alarm threshold.

FRF.8 Encapsulation Mode

Possible SettingsTranslational, Transparent Default Setting: Transparent

Specifies the type of FRF.8 upper-layer protocol encapsulation used on the link for each pair of interoperable Frame Relay and ATM PVCs.

Translational – Encapsulated data is translated (RFC 1490 to RFC 1483). FrameSaver multiplexing and SLV communications are not supported in this mode.

Transparent – Encapsulated data is forwarded without being translated.

ILMI

Possible SettingsEnable, Disable Default Setting: Enable

Specifies the state of the Integrated Local Management Interface (ILMI). ILMI can be used in support of hybrid management, allowing access to the endpoint from a DSL provider’s Network Operation Center using the same management PVC that is used to manage the DSLAM.

Enable – The ILMI channel is enabled. SNMP traffic, embedded in the ATM cells, is supported.

Disable – The ILMI channel is disabled.

Cell Payload Scrambling

Page 104 of the Paradyne 9623 user manual — Table 3-29. PVC Connection Options (1 of 4)
Page 104 · click to enlarge
Page 104

Configuring PVC Connections

The Auto-Configuration feature automatically configures PVC Connections and their DLCI Records. PVC Connections can also be created manually (see Table 3-29, PVC Connection Options).

Main Menu→Configuration→PVC Connections

From this screen, you can go directly to the Management PVC screen by selecting the MgmtPVCs function key for easy movement between screens.

Quick removal of unused DLCIs (and ISDN Link Profiles, except for HQ_Site, if the model has an ISDN DBM installed) included in an existing PVC Connection is also available when the Delete function key is selected and you respond Yes to the Remove otherwise unused components associated with the deleted PVC? prompt.

Table 3-29. PVC Connection Options (1 of 4)

Possible Settings: Port-n, ISDN Link Name, Net1-FR1, Rtr-S0 Default Setting: Initially blank; no default.

Specifies the frame relay interface that starts a PVC connection; the from end of a from-to link. The only valid settings for this configuration option are frame relay interfaces that have at least one DLCI or EDLCI defined that are not part of a PVC connection or management link. For example, if Port-1 has no DLCIs defined, Port-1 would not appear as a valid setting.

Net1-FR1 – Specifies that the network interface be used in the connection.

ISDN Link Name – For units with ISDN backup capability, specifies the ISDN link of the DBM as the source link. This can be any nonnull link name configured on an ISDN frame relay link.

Port-n – For CSU/DSUs, specifies that the frame relay link on the user data port be used in the connection.

Rtr-S0 – For FrameSaver routers, specifies that the frame relay link on the virtual router port be used in the connection.

Clear All – Clears all Link and DLCI settings, and suppresses EDLCIs.

Possible Settings: 16 – 1007 Default Setting: Initially blank; no default.

Specifies the source DLCI for a frame relay interface. The DLCI must be defined and cannot be part of a PVC connection or management link. For multiplexed DLCIs, at least one EDLCI must be unconnected for the DLCI to be a valid selection.

16. 1007 – Specifies the DLCI number.

Source Link · Source DLCI

Page 105 of the Paradyne 9623 user manual — NOTES:
Page 105 · click to enlarge
Page 105

Table 3-29. PVC Connection Options (2 of 4)

Possible Settings: 0 – 62 Default Setting: Initially blank; no default.

Specifies the source Embedded Data Link Connection Identifier (EDLCI) for a frame relay interface when a multiplexed DLCI record is selected as one end of a connection.

Display Conditions – This option only appears when Source DLCI contains a multiplexed DLCI record number.

0. 62 – Specifies the EDLCI number.

Possible Settings: Net1-FR1, ISDN Link Name, Rtr-S0 Default Setting: Initially blank; no default.

Specifies the frame relay interface used as the primary destination link; the to end of a from-to link. The only valid settings for this configuration option are frame relay interfaces that have at least one DLCI or EDLCI defined which are not part of a PVC connection or management link. For example, if the network interface has no DLCIs defined, Net1-FR1 would not appear as a valid setting.

Net1-FR1 – Specifies the Network interface as the destination link.

ISDN Link Name – For units with ISDN backup capability, specifies the ISDN link of the DBM as the destination of the connection. This can be any nonnull link name configured on an ISDN frame relay link.

Rtr-S0 – For FrameSaver routers, specifies the virtual router port as the destination link.

Possible Settings: 16 – 1007 Default Setting: Initially blank; no default.

Specifies the primary destination DLCI for a frame relay interface. The DLCI must be defined and cannot be part of a PVC connection or management link. For multiplexed DLCIs, at least one EDLCI must be unconnected for the DLCI to be a valid selection.

NOTES:

– Primary Destination DLCI has no value if Primary Destination Link contains no

value.

– When an ISDN DBM is installed and the DLCI assigned to the PVC is in a Backup

Group (see Table 3-26, DLCI Record Options), the letter designation assigned to the group of DLCIs appears next to the primary destination DLCI number on the Management PVCs Options screen.

16. 1007 – Specifies the DLCI number.

Source EDLCI · Primary Destination Link · Primary Destination DLCI

Page 106 of the Paradyne 9623 user manual — Table 3-29. PVC Connection Options (3 of 4)
Page 106 · click to enlarge
Page 106

Table 3-29. PVC Connection Options (3 of 4)

Possible Settings: 0 – 62 Default Setting: Initially blank; no default.

Specifies the primary destination Embedded Data Link Connection Identifier (EDLCI) for a frame relay interface when a multiplexed DLCI record is selected as one end of a connection.

Display Conditions – This option only appears when the Primary Destination DLCI contains a multiplexed DLCI record number. For a DLCI that is:

– IP Enabled, IP appears in this field

– Payload Managed (but not IP Enabled), PM appears in this field

0. 62 – Specifies the EDLCI number.

Possible Settings: Net1-FR1, ISDN Link Name Default Setting: Initially blank; no default.

Specifies the frame relay interface used as the alternate destination link; the to end of a from-to link that is used for backup when the primary destination link or DLCI is out of service. The only valid settings for this configuration option are frame relay interfaces that have at least one DLCI or EDLCI defined which are not part of a PVC connection or management link. For example, if ISDN Link Name has no DLCIs defined, the ISDN link name would not appear as a valid setting.

Net1-FR1 – Specifies the Network interface as the destination link.

ISDN Link Name – Specifies the ISDN link of the DBM as the destination of the connection. This can be any non-null link name configured on an ISDN frame relay link on an installed DBM.

Clear Alternate – Clears the Alternate Destination Link and Alternate Destination DLCI settings, and suppresses Alternate Destination EDLCI.

Possible Settings: 16 – 1007 Default Setting: Initially blank; no default.

Specifies the alternate destination Data Link Connection Identifier (DLCI) for a frame relay interface used for backup. The DLCI must be defined and cannot be part of a PVC connection or management link. For multiplexed DLCIs, at least one EDLCI must be unconnected for the DLCI to be a valid selection.

Display Conditions – This option does not appear when the Alternate Destination Link contains no value.

16. 1007 – Specifies the DLCI number.

Primary Destination EDLCI · Alternate Destination Link · Alternate Destination DLCI

Page 107 of the Paradyne 9623 user manual — Table 3-29. PVC Connection Options (4 of 4)
Page 107 · click to enlarge
Page 107

Table 3-29. PVC Connection Options (4 of 4)

Possible Settings: 0 – 62 Default Setting: Initially blank; no default.

Specifies the alternate destination Embedded Data Link Connection Identifier (EDLCI) for a frame relay interface when a multiplexed DLCI record is selected as one end of a backup connection.

Display Conditions – This option only appears when the Alternate Destination DLCI contains a multiplexed DLCI record number.

0. 62 – Specifies the EDLCI number.

Alternate Destination EDLCI

Page 108 of the Paradyne 9623 user manual — FWD
Page 108 · click to enlarge
Page 108

Configuring the IP Path List

Select IP Path List (Static) from the Configuration Edit/Display menu to display or change the list of static path IP addresses explicitly defined in the unit.

Main Menu→Configuration→IP Path List (Static)

The IP Path List (Static) screen appears, showing any existing static paths. Paths discovered as SLV packets are received from other FrameSaver units are not shown. To view the entire current IP Path List, use the IP Path Connection Status screen. See the FrameSaver SLV Operations Guide for more information.

Procedure

To add a static path:

1. Select New. The following prompt appears:

Enter IP Address (press ESC to abort): FWD: No

2. Enter the IP address of a static path and select a forwarding option of No or Yes using the spacebar.
3. Press enter. Select Save.

Table 3-30. IP Path List

Possible Settings: 000.000.000.001 – 126.255.255.255, 128.000.000.000 – 223.255.255.255 Default Setting: Initially blank; no default.

Specifies the address of a FrameSaver or other device at the other end of a path.

000.000.000.001 – 126.255.255.255, 128.000.000.000 – 223.255.255.255 – Specifies the address of a device.

FWD

Possible SettingsNo, Yes Default Setting: No

Determines whether this path list item is sent to all other addresses in the list that represent FrameSaver devices.

No – The IP address associated with this path list item is not distributed.

Yes – The IP address associated with this path list entry is distributed to devices in the list.

IP Address

Page 109 of the Paradyne 9623 user manual — Setting Up Management and Communication Options
Page 109 · click to enlarge
Page 109

Setting Up Management and Communication Options

Management and Communications options are explained in the following sections:

Configuring Node IP Information

Configuring Management PVCs

Configuring General SNMP Management

Configuring Telnet and/or FTP Session Support

Configuring SNMP NMS Securitys

Configuring SNMP Traps and Trap Dial-Out

Configuring Ethernet Management

Configuring the Communication Port

Configuring the Modem Port

Configuring the Criteria for Automatic Backup

Page 110 of the Paradyne 9623 user manual — Table 3-31. Node IP Options (1 of 4)
Page 110 · click to enlarge
Page 110

Configuring Node IP Information

Select Node IP to display, add, or change the information necessary to support general IP communications for the node (see Table 3-31, Node IP Options). When deploying units to remote sites, minimally configure the Node IP Address and Subnet Mask.

Main Menu→Configuration→Management and Communication→Node IP

This set of configuration options includes a Troubleshooting (TS) Management Access Link feature to help service providers isolate device problems within their networks. This feature allows Telnet or FTP access to the unit on this link. Troubleshooting over this link is essentially transparent to customer operations. No alarms or SNMP traps are generated to create nuisance alarms for the customer.

TS_Access_Management_Link is initially disabled in most models, but the link can be enabled at any time. Any valid network Management PVC created on a standard DLCI can be used. When enabled, a troubleshooting link can be accessed any time the service provider requests access. An assigned security level can also control access.

When a DLCI has been defined as the troubleshooting management link, the link is identified in the status field at the bottom of the Management PVC Entry screen with the Note: This PVC has been designated as the TS Access Management Link message.

NOTE:

The unit may come from the factory with a TS Management PVC already set up (e.g., 980).

Table 3-31. Node IP Options (1 of 4)

Possible Settings001.000.000.000 – 223.255.255.255, Clear Default Setting: Clear (000.000.000.000)

Specifies the IP address needed to access the node. Since an IP address is not bound to a particular port, it can be used for remote access via a management PVC.

001.000.000.000 – 223.255.255.255 – Shows the IP address for the node, which can be viewed or edited.

Clear – Fills the node IP address with zeros.

Node IP Address

Page 111 of the Paradyne 9623 user manual — Table 3-31. Node IP Options (2 of 4)
Page 111 · click to enlarge
Page 111

Table 3-31. Node IP Options (2 of 4)

Possible Settings000.000.000.000 – 255.255.255.255, Clear Default Setting: 000.000.000.000

Specifies the subnet mask needed to access the node. Since the subnet mask is not bound to a particular port, it can be used for remote access via a management PVC.

000.000.000.000 – 255.255.255.255 – Shows the subnet mask for the node, which can be viewed or edited.

Clear – Fills the node subnet mask with zeros. When the node’s subnet mask is all zeros, the IP protocol creates a default subnet mask based upon the class of the IP address: Class A: 255.000.000.000, Class B: 255.255.000.000, or Class C: 255.255.255.000.

Possible SettingsNone, Modem, COM, Ethernet, PVCname Default Setting: None

Specifies an IP destination to route data that does not have a specifically defined route.

Examples:

If the default IP network is connected to the communications port, select COM.

If the default IP network is connected to a far-end device over the management PVC

named London for the remote device located in the London office, select the PVC name London (as defined by the Name configuration option, Table 3-32, Management PVC Options). NOTE: If the link to the IP destination selected as the default route becomes disabled or down, the unrouteable data will be discarded. Make sure that the link selected is operational, and if that link goes down, change the default destination. CAUTION: Use care when configuring a default route to an interface that has a subnet route configured at a remote end where the NMS, router, LAN adapter, terminal server, etc. is connected. Communicating with an unknown IP address on the subnet will cause temporary routing loops, which will last 16 iterations times the retry count.

None – No default network destination is specified. Unrouteable data will be discarded. This is the recommended setting.

Modem – Specifies that the default destination is connected to the modem port. Only appears when the modem port Use option is set to Net Link.

COM – Specifies that the default destination is connected to the COM port. Only appears when Port Use is set to Net Link (see Table 3-38, Communication Port Options).

Ethernet – For the FrameSaver SLV 9126 or 9128, specifies that the default destination is connected to the Ethernet port. Only appears when the Ethernet port’s Interface Status option is enabled. When selected, the Default Gateway Address must also be configured (see Table 3-37, Ethernet Management Options).

PVCname – Specifies a name for the management PVC. Only appears when a management PVC name is defined for the node. For example, when the network is connected to a remote device located in the London office, London can be specified as the PVC name, which is the link between the local FrameSaver unit and the one located in London. London would appear as one of the available selections.

Node Subnet Mask · Default IP Destination

Page 112 of the Paradyne 9623 user manual — Table 3-31. Node IP Options (3 of 4)
Page 112 · click to enlarge
Page 112

Table 3-31. Node IP Options (3 of 4)

Possible Settings90 – 1500 Default Setting: 1500

Specifies the Maximum Transmission Unit (MTU) for management traffic transmitted on standard DLCIs, EDLCIs, IP tunnels, and Payload Management circuits.

90. 1500 – Specifies the MTU size.

TS Access Management Link

Available SettingsNone, PVCname Default Setting: None

Specifies a troubleshooting management link for the special needs of network service providers.

If the setting is changed from the management PVC name to None, the Delete the Management PVC PVCname and the associated DLCI Record? prompt appears. If you select:

No – The link designation is removed and the option is set to None.

Yes – The link designation is removed and the option is set to None, and the link

and its DLCI will be deleted.

Display Conditions – This option appears only when Service Type is Frame Relay.

None – Disables or does not specify a TS Access Management Link.

PVCname – Specifies the name of the TS Management PVC. This selection only appears when a dedicated management PVC has been defined on the network frame relay link as a DLCI with DLCI Type set to Standard.

TS Management Link Access Level

Available SettingsLevel-1, Level-2 , Level-3 Default Setting: Level-1

Specifies the highest access level allowed when accessing the unit via a Telnet or FTP session when the service provider is using the TS Access Management Link.

Display Conditions – This option only appears when:

Service Type on the Easy Install screen is set to Frame Relay.

TS Access Management Link is set to a PVC name.

Session Access Level, Login Required, or FTP Login Required option settings (see Table 3-34, Telnet and FTP Session Options).

– Telnet and FTP sessions on this link are affected by the Telnet Session, Inactivity

Timeout, Disconnect Time and FTP Session option settings.

Level-1 – Allows Telnet or FTP access by network service providers with the capability to view unit information, change configuration options, and run tests. This is the highest access level allowed. Use this setting when downloading files.

Level-2 – Allows Telnet or FTP access by network service providers with the capability to view unit information and run tests only; they cannot change configuration options.

Level-3 – Allows Telnet access by network service providers with the capability to view unit information only; they cannot change configuration options or run tests.

Management MTU Size

Page 113 of the Paradyne 9623 user manual — Table 3-31. Node IP Options (4 of 4)
Page 113 · click to enlarge
Page 113

Table 3-31. Node IP Options (4 of 4)

TS Management SNMP Validation

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether validation of community strings and IP addresses is performed for this management link.

Display Conditions – This option only appears when:

Service Type on the Easy Install screen is set to Frame Relay.

TS Access Management Link is set to a PVC name.

Enable – Validation of community strings and IP addresses is performed on SNMP traffic.

Disable – No validation of community strings and IP addresses is performed.

Page 114 of the Paradyne 9623 user manual — Table 3-32. Management PVC Options (1 of 6)
Page 114 · click to enlarge
Page 114

Configuring Management PVCs

Select Management PVCs to define inband management links by adding or changing Management PVCs (see Table 3-32, Management PVC Options). First, DLCI records must have been configured for the interface where the Management PVC will reside. See Manually Configuring DLCI Records on page 3-64 for additional information.

Main Menu→Configuration→Management and Communication→ Management PVCs

Select New or Modify to add or change Management PVCs.

When you select New, the configuration option field is blank.

When you select Modify, the values displayed for all fields are based on the PVC ID number that you specified.

These options do not apply when the Management PVC is designated as a TS Management Link (see Configuring Node IP Information on page 3-78 for additional information).

From this screen, you can go directly to the PVC Connections screen by selecting the PVCConn function key for easy movement between screens.

Select the Delete function key, a Management PVC ID#, and respond Yes to the Remove otherwise unused components associated with the deleted PVC? prompt for quick removal of unused DLCIs. If the Management PVC selected is defined as a trap Initial Route Destination, a Default IP Destination, or a TS Access Management Link, an ... Are You Sure? prompt is displayed to warn you.

An IP Enabled circuit is identified by IP in the EDLCI or Type field of the Management PVCs Options screen. It may be viewed and modified, but not created or deleted. IP Enabled PVCs are created when an IP Enabled DLCI is created on the network interface, and deleted when the DLCI is deleted or changed to Standard.

A payload management circuit is identified by PM in the EDLCI or Type field of the Management PVCs Options screen. If a payload management management circuit is deleted, the associated PVC remains standard, even if was a multiplexed PVC (automatically converted to standard) when it the management circuit was created.

If an existing PVC with an associated payload managed management circuit is deleted, then the payload management circuit is also deleted.

Table 3-32. Management PVC Options (1 of 6)

Possible Settings: ASCII Text Entry Default Setting: Initially blank; no default.

Specifies a unique name for the management PVC as referenced on screens (e.g., Tampa for Tampa, Florida).

ASCII Text Entry – Enter a unique name for the management PVC (maximum length 8 characters).

Name

Page 115 of the Paradyne 9623 user manual — Table 3-32. Management PVC Options (2 of 6)
Page 115 · click to enlarge
Page 115

Table 3-32. Management PVC Options (2 of 6)

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether the PVC is payload managed.

Display Conditions – This is a read-only field set to Enabled if the PVC is IP Enabled.

Enable – The network PVC created will be monitored for the presence of IP frames containing the IP address specified in the Intf IP Address field. When such a frame is identified, it is extracted from the data stream and sent to the management stack.

Disable – A normal management PVC is created using the specified DLCI or EDLCI.

Possible SettingsNode-IP-Address, Special ( nnn . nnn . nnn . nnn ) Default Setting: Node-IP-Address

Specifies the IP address needed to access the unit via this management PVC, providing connectivity to an external IP network through the frame relay network.

Node-IP-Address – Uses the IP address contained in the Node IP Address (see Table 3-31, Node IP Options).

Special (001.000.000.000 – 223.255.255.255) – Allows you to display/edit an IP address for the unit’s management PVC when the IP address for this interface is different from the node’s IP address.

Possible Settings: Node-Subnet-Mask, Calculate, Special (nnn.nnn.nnn.nnn) Default Setting: Node-Subnet-Mask

Specifies the subnet mask needed to access the unit when the management PVC is providing connectivity to an external IP network (through frame relay) that requires a specific subnet mask for the interface.

Node-Subnet-Mask – Uses the Interface IP Subnet contained in the Node-Subnet Mask configuration option (see Table 3-31, Node IP Options).

Calculate – Calculates the subnet mask created by the IP protocol based on the class of the IP address (Class A: 255.000.000.000, Class B: 255.255.000.000, or Class C: 255.255.255.000). Cannot be displayed or edited.

Special (000.000.000.000 – 255.255.255.255) – Allows you to edit/display the subnet mask for the management PVC when the subnet mask is different for this interface. A text field displays where you can enter the subnet mask for this unit’s management PVC.

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether frames (packets) sent on a management PVC have the Discard Eligible (DE) bit set. This bit is used by the network to prioritize which frames to discard first during periods of network congestion. This allows management traffic to be viewed as lower priority than customer data.

Enable – Sets the DE bit to one on all frames sent on the management PVC.

Disable – Sets the DE bit to zero on all frames sent on the management PVC. This is the recommended setting, particularly for NSPs providing a managed network service.

Show 4 more labels / short text on this page
Payload Managed · Intf IP Address · Intf Subnet Mask · Set DE
Page 116 of the Paradyne 9623 user manual — NOTES:
Page 116 · click to enlarge
Page 116

Table 3-32. Management PVC Options (3 of 6)

Possible Settings: Net1-FR1, Port-n, Rtr-S0, ISDN Link Name, Clear Default Setting: Initially blank; no default.

Specifies the frame relay interface to use for this management PVC. The interface selected must have at least one DLCI (or DLCI with EDLCI) defined, which is not part of a PVC connection or already assigned as a management PVC.

Display Conditions – The Port-1 setting does not appear if the PVC is IP Enabled or Payload Managed is enabled.

Net1-FR1 – Specifies the network interface as the source link for the connection.

Port-n – Specifies the frame relay link on the user data port as the destination link for the connection.

Rtr-S0 – For FrameSaver routers, specifies that the vertual router port be used in the connection.

ISDN Link Name – For units with ISDN backup capability, specifies the ISDN link on the DBM to be used in the connection. This can be any nonnull link name configured on an ISDN frame relay link on an installed DBM.

Clear – Clears the link and the DLCI field, and suppresses the EDLCI field if the DLCI was multiplexed.

Possible Settings: 16 – 1007 Default Setting: Initially blank; no default.

Specifies the DLCI number used for the management PVC after the frame relay interface is selected.

The DLCI must be defined for the link (i.e., has a DLCI record), and it must not be part of a PVC connection or already assigned as a management PVC. For multiplexed DLCIs, at least one EDLCI must be unconfigured for the DLCI.

NOTES:

– DLCI cannot be entered if the Link field is blank. – Clearing the Link also clears the DLCI.

– When an ISDN DBM is installed and the DLCI assigned to the PVC is in a Backup

Group (see Table 3-26, DLCI Record Options), the letter designation assigned to the group of DLCIs appears next to the primary destination DLCI number on the Management PVCs Options screen.

16. 1007 – Specifies the DLCI number (inclusive).

Primary Link · Primary DLCI

Page 117 of the Paradyne 9623 user manual — Table 3-32. Management PVC Options (4 of 6)
Page 117 · click to enlarge
Page 117

Table 3-32. Management PVC Options (4 of 6)

Possible Settings: 0 – 62 Default Setting: Initially blank; no default.

Specifies the EDLCI number used for a management PVC when a multiplexed DLCI is selected. EDLCIs identify individual connections within multiplexed DLCIs that are unique to those DLCIs.

Use a unique EDLCI to identify an individual connection within a multiplexed DLCI. Use 0 to identify the primary EDLCI. Use 1 – 62 to identify secondary EDLCIs. Use the primary EDLCI for customer data, which has a higher utilization rate than management data, with slightly less line overhead.

Display Conditions – This option does not appear if the DLCI field does not reference a multiplexed DLCI, if the PVC is IP Enabled, or if Payload Managed is enabled.

0. 62 – Specifies the EDLCI number (inclusive).
Possible SettingsNone, Proprietary, Standard_out Default Setting:
For multiplexed DLCIsProprietary For nonmultiplexed DLCIs: Standard_out

Specifies which Routing Information Protocol (RIP) is used to enable routing of management between FrameSaver units and attached equipment.

Display Conditions – This option does not appear if the PVC is IP Enabled or Payload Managed is enabled.

None – Does not use a routing protocol.

Proprietary – Uses a proprietary variant of RIP version 1 to communicate routing information between FrameSaver units. A FrameSaver unit must be on the other end of the link. This is the factory default for management PVCs configured on multiplexed DLCIs (see Table 3-26, DLCI Record Options).

Proprietary-In – Like Proprietary, except that only local routes are passed to the far end.

Standard_out – The device will send standard RIP messages to communicate routing information only about FrameSaver devices in the network. This is the factory default for management PVCs configured on standard DLCIs.

Primary EDLCI · Primary Link RIP

Page 118 of the Paradyne 9623 user manual — Table 3-32. Management PVC Options (5 of 6)
Page 118 · click to enlarge
Page 118

Table 3-32. Management PVC Options (5 of 6)

Possible Settings: Net1-FR1, Port-n, ISDN Link Name, Clear Default Setting: Initially blank; no default.

Specifies the frame relay interface to use for this management PVC as the alternate link. The interface selected must have at least one DLCI (or DLCI with EDLCI) defined, which is not part of a PVC connection or already assigned as a management PVC.

Display Conditions – This option does not appear unless ISDN backup is available, and does not appear if Payload Managed is enabled.

Net1-FR1 – Specifies the Network interface as the frame relay link.

Port-n – Specifies the frame relay link on the user data port as the alternate destination link for the connection.

ISDN Link Name – For units with ISDN backup capability, specifies the ISDN link of the DBM to be used in the connection. This can be any nonnull link name configured on an ISDN frame relay link on an installed DBM.

Clear – Clears the link and the DLCI field, and suppresses the EDLCI field if the DLCI was multiplexed.

Possible Settings: 16 – 1007 Default Setting: Initially blank; no default.

Specifies the alternate DLCI number to be used for the management PVC after the frame relay interface is selected.

The DLCI must be defined for the link (i.e., has a DLCI record), and it must not be part of a PVC connection or already assigned as a management PVC. For multiplexed DLCIs, at least one EDLCI must be unconfigured for the DLCI.

Display Conditions – This option does not appear if Payload Managed is enabled. The DLCI cannot be entered if the Link field is blank.

16. 1007 – Specifies the DLCI number (inclusive).

Possible Settings: 0 – 62 Default Setting: Initially blank; no default.

Specifies the alternate EDLCI number used for a management PVC when a multiplexed DLCI is selected for the frame relay link. EDLCIs identify individual connections within multiplexed DLCIs that are unique to those DLCIs.

Use a unique EDLCI to identify an individual connection within a multiplexed DLCI. Use 0 to identify the primary EDLCI. Use 1 – 62 to identify secondary EDLCIs. Use the primary EDLCI for customer data, which has a higher utilization rate than management data, with slightly less line overhead.

Display Conditions – This option does not appear unless ISDN backup is available and the DLCI field does not reference a multiplexed DLCI. This option does not appear if Payload Managed is enabled.

0. 62 – Specifies the EDLCI number (inclusive).

Alternate Link · Alternate DLCI · Alternate EDLCI

Page 119 of the Paradyne 9623 user manual — Table 3-32. Management PVC Options (6 of 6)
Page 119 · click to enlarge
Page 119

Table 3-32. Management PVC Options (6 of 6)

Possible SettingsRouted Default Setting: Routed

This read-only field specifies that the IP encapsulation used is RFC 1490/RFC 2427 routed Network Level Protocol IDentifier (NLPID) encapsulation, and not SubNetwork Access Protocol (SNAP) encapsulation.

Display Conditions – This option appears only if the PVC is IP Enabled or Payload Managed is enabled.

Routed – IP encapsulation is routed NLPID.

Encapsulation

Page 120 of the Paradyne 9623 user manual — Table 3-33. General SNMP Management Options (1 of 2)
Page 120 · click to enlarge
Page 120

Configuring General SNMP Management

Select General SNMP Management to add, change, or delete the information needed to allow the FrameSaver unit to be managed as an SNMP agent by the NMS supporting the SNMP protocols (see Table 3-33, General SNMP Management Options).

Main Menu→Configuration→Management and Communication→ General SNMP Management

You must have Level-1 access to display or configure these options.

Table 3-33. General SNMP Management Options (1 of 2)

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether the FrameSaver unit can be managed as an SNMP agent by an SNMP-compatible NMS.

Enable – Can be managed as an SNMP agent.

Disable – Cannot be managed as an SNMP agent. The FrameSaver unit will not respond to SNMP messages nor send SNMP traps.

Possible SettingsASCII text entry , Clear Default Setting: Public in ASCII text field

Specifies the first of two names that are allowed to access the objects in the FrameSaver unit’s MIB. The community name must be supplied by an external SNMP manager whenever the manager tries to access an object in the MIB.

ASCII text entry – Adds to or changes Community Name 1 (maximum 255 characters).

Clear – Clears Community Name 1.

Possible SettingsRead, Read/Write Default Setting: Read/Write

Specifies the type of access allowed to the objects in the MIB. This is the type of access allowed for external SNMP managers accessing MIB objects using Community Name 1.

Read – Allows read-only access (SNMP Get command). This includes all objects specified as either read-only or read/write in the MIB RFCs.

Read/Write – Allows read and write access (SNMP get and set commands).

Possible SettingsASCII text entry , Clear Default Setting: Clear

Specifies the second of two names that are allowed to access the objects in the FrameSaver unit’s MIB. The community name must be supplied by an external SNMP manager whenever the manager tries to access an object in the MIB.

ASCII text entry – Adds to or changes Community Name 2 (maximum 255 characters).

Clear – Clears Community Name 2.

Show 4 more labels / short text on this page
SNMP Management · Community Name 1 · Name 1 Access · Community Name 2
Page 121 of the Paradyne 9623 user manual — Configuring Telnet and/or FTP Session Support
Page 121 · click to enlarge
Page 121

Table 3-33. General SNMP Management Options (2 of 2)

Possible SettingsRead, Read/Write Default Setting: Read

Specifies the type of access allowed to the objects in the MIB. This is the type of access allowed for external SNMP managers accessing MIB objects using Community Name 2.

Read – Allows read-only access (SNMP Get command). This includes all objects specified as either read-only or read/write in the MIB RFCs.

Read/Write – Allows read and write access (SNMP get and set commands).

Configuring Telnet and/or FTP Session Support

Telnet and FTP options control whether a Telnet or FTP (File Transport Protocol) session is allowed through an interconnected IP network and the access security applicable to the session. Two Telnet sessions can be active at a time (see Table 3-34, Telnet and FTP Session Options).

Main Menu→Configuration→Management and Communication→ Telnet and FTP Session

When a TS Access Management Link has been set up and activated, the following options have no effect upon the PVC:

Telnet Login Required

Session Access Level

FTP Login Required

Name 2 Access

Page 122 of the Paradyne 9623 user manual — Table 3-34. Telnet and FTP Session Options (1 of 2)
Page 122 · click to enlarge
Page 122

Table 3-34. Telnet and FTP Session Options (1 of 2)

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether the FrameSaver unit will respond to a session request from a Telnet client on an interconnected IP network.

Enable – Allows Telnet sessions between the FrameSaver unit and Telnet client.

Disable – Does not allow Telnet sessions.

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether a user ID and password (referred to as the login) are required to access the menu-driven user interface via a Telnet session. If required, the login used is the same login used for an menu-driven user interface session. This option does not affect the TS Access Management Link.

Enable – Requires a login to access a Telnet session.

Disable – Does not require a login.

Possible SettingsLevel-1, Level-2, Level-3 Default Setting: Level-1

Specifies the highest security level allowed when accessing the menu-driven user interface via a Telnet session. If a login is required for the session, the effective access level is also determined by the user’s access level. When a login is not required, the effective access level is determined by this option. This option does not affect the TS Access Management Link.

Level-1 – Allows Telnet access by users with Login ID access levels of 1, 2, and 3, with the capability to view system information, change configuration options, and run tests. This is the highest access level allowed.

CAUTION: Before changing the session access level to Level-2 or 3, make sure that the COM port’s Port Access Level is set to Level-1 and that at least one Login ID is set to Level-1. Otherwise, access will be lost. If this occurs, you must reset the unit to the factory defaults and begin the configuration process again. A reset is required if the Communication Port’s Port Use option is set to Net Link (see Table 3-6, General System Options).

Level-2 – Allows Telnet access by users with Login ID access levels of 1, 2, and 3, with the capability to view system information and run tests only; they cannot change configuration options.

Level-3 – Allows Telnet access by users with Login ID access levels of 1, 2, and 3, with the capability to view system information only; they cannot change configuration options or run tests.

Telnet Session · Telnet Login Required · Session Access Level

Page 123 of the Paradyne 9623 user manual — Table 3-34. Telnet and FTP Session Options (2 of 2)
Page 123 · click to enlarge
Page 123

Table 3-34. Telnet and FTP Session Options (2 of 2)

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether a Telnet session is disconnected after a specified period of keyboard inactivity.

Enable – Terminates the session after the Disconnect Time expires.

Disable – Does not terminate Telnet session during inactivity.

Possible Settings1 – 60 Default Setting: 10

Sets the amount of keyboard inactive time allowed before a user session is disconnected.

Display Conditions – This option does not appear when Inactivity Timeout is disabled.

1. 60 – Up to an hour can be set.
Possible SettingsEnable, Disable Default Setting: Enable

Determines whether the system responds as a server when an FTP (file transfer protocol) client on an interconnected IP network requests an FTP session. This option must be enabled when downloading files.

Enable – Allows an FTP session between the system and an FTP client.

Disable – Does not allow FTP sessions.

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether a login ID and password are required for an FTP session. If required, the login used is the same login used for a menu-driven user interface session. This option does not affect the TS Access Management Link.

Enable – User is prompted for a login ID and password.

Disable – No login is required for an FTP session.

FTP Max Transfer Rate (Kbps)

Possible Settings1 – 1536 Default Setting: 1536

Sets the maximum receive (or send) rate of file transfer to the system via management PVCs. This option allows new software and configuration files to be downloaded using selected bandwidth without interfering with normal operation. Using this option, new software and configuration files can be downloaded quickly using the default settings, or at a slower rate over an extended period of time by selecting a slower speed. Based upon TCP flow control, the FTP server in the system throttles bandwidth to match this setting.

1. 1536 – Sets the download line speed from 1 kilobits per second to the maximum management speed.
Show 4 more labels / short text on this page
Inactivity Timeout · Disconnect Time (Minutes) · FTP Session · FTP Login Required
Page 124 of the Paradyne 9623 user manual — Table 3-35. SNMP NMS Security Options (1 of 2)
Page 124 · click to enlarge
Page 124

Configuring SNMP NMS Security

Select SNMP NMS Security from the Management and Communication menu to display, add, or change SNMP security configuration options for the FrameSaver unit to set up trap managers (see Table 3-35, SNMP NMS Security Options).

Main Menu→Configuration→Management and Communication→ SNMP NMS Security

A table is displayed consisting of the network management systems identified by IP address that are allowed to access the FrameSaver unit by SNMP.

Table 3-35. SNMP NMS Security Options (1 of 2)

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether security checks are performed on the IP address of SNMP management systems attempting to access the node. Only allows access when the sending manager’s IP address is listed on the SNMP NMS Security Options screen.

Enable – Performs security checks.

Disable – Does not perform security checks.

Possible Settings1 – 10 Default Setting: 1

Specifies the number of SNMP management systems that are authorized to send SNMP messages to the FrameSaver unit. An IP address must be configured for each management system allowed to send messages. Configure IP addresses in the NMS n IP Address configuration option.

1. 10 – Specifies the number of authorized SNMP managers.

NMS n IP Address

Possible Settings001.000.000.000 – 223.255.255.255, Clear Default Setting: Clear (000.000.000.000)

Provides the IP address of an SNMP manager that is authorized to send SNMP messages to the unit. If an SNMP message is received from an unauthorized NMS and its IP address cannot be matched here, access is denied and an authenticationFailure trap is generated. If a match is found, the type of access (read-only or read/write) is determined by the corresponding Access Type.

Display Conditions – This option appears for each trap manager specified in the Number of Trap Managers configuration option.

001.000.000.000 – 223.255.255.255 – Adds to or changes the NMS IP address.

Clear – Fills the NMS IP address with zeros.

NMS IP Validation · Number of Managers

Page 125 of the Paradyne 9623 user manual — Table 3-36. SNMP Traps and Trap Dial-Out Options (1 of 6)
Page 125 · click to enlarge
Page 125

Table 3-35. SNMP NMS Security Options (2 of 2)

Possible SettingsRead, Read/Write Default Setting: Read

Specifies the type of access allowed for an authorized NMS when IP address validation is performed.

Display Conditions – This option appears for each trap manager specified in the Number of Trap Managers configuration option.

Read – Allows read-only access (SNMP Get command) to the MIB objects. This includes all objects specified as either read-only or read/write in the MIB RFCs.

Read/Write – Allows read and write access (SNMP Get and Set commands) to the MIB objects. However, access for all read-only objects is specified as read-only.

Configuring SNMP Traps and Trap Dial-Out

Select SNMP Traps from the Management and Communication menu to configure SNMP traps and dial-out when a trap is generated (see Table 3-36, SNMP Traps and Trap Dial-Out Options).

Main Menu→Configuration→Management and Communication→ SNMP Traps

See the FrameSaver SLV SNMP Reference for trap format standards and special trap features, including RMON-specific traps, and the default settings that will generate RMON-specific SNMP traps.

Table 3-36. SNMP Traps and Trap Dial-Out Options (1 of 6)

Possible SettingsEnable, Disable Default Setting: Disable

Determines whether the FrameSaver unit sends trap messages to the currently configured SNMP trap manager(s).

Enable – Sends trap messages.

Disable – Does not send trap messages.

Number of Trap Managers

Possible Settings1 – 6 Default Setting: 1

Specifies the number of SNMP management systems that will receive SNMP trap messages from the FrameSaver unit. An NMS IP Address must be configured in the NMS n IP Address configuration option for each trap manager to receive trap messages.

1. 6 – Specifies the number of trap managers (inclusive).

Access Type · SNMP Traps

Page 126 of the Paradyne 9623 user manual — Table 3-36. SNMP Traps and Trap Dial-Out Options (2 of 6)
Page 126 · click to enlarge
Page 126

Table 3-36. SNMP Traps and Trap Dial-Out Options (2 of 6)

NMS n IP Address

Possible Settings001.000.000.000 – 223.255.255.255, Clear Default Setting: Clear (000.000.000.000)

Specifies the IP address that identifies the SNMP manager(s) to receive SNMP traps.

Display Conditions – This option appears for each trap manager specified in the Number of Trap Managers configuration option.

001.000.000.000 – 223.255.255.255 – Adds to or changes the IP address for the trap manager.

Clear – Fills the NMS IP address with zeros.

Possible SettingsAutoRoute, Modem, COM, Ethernet, PVCname Default Setting: AutoRoute

Specifies the initial route used to reach the specified Trap Manager. When proprietary RIP is active, only one unit in the network needs to specify an interface or management link as the initial destination. All other units can use the default setting.

Display Conditions – This option appears for each trap manager specified in the Number of Trap Managers configuration option.

AutoRoute – Uses proprietary RIP from other FrameSaver devices to learn the route for sending traps to the specified Trap Manager, or the Default IP Destination when no route is available in the routing table (see Table 3-31, Node IP Options).

Modem – Uses the Modem port. This selection only appears if the Modem Port Use configuration option is set to Net Link (see Table 3-39, Modem Port Options).

COM – Uses the COM port. This selection is only available when Port Use is set to Net Link (see Table 3-38, Communication Port Options).

Ethernet – For the FrameSaver SLV 9126 or 9128, uses the Ethernet port. Only appears when the Ethernet port’s Interface Status option is enabled (see Table 3-37, Ethernet Management Options).

PVCname – Uses the defined management linkname (the name given the Management PVC). This selection only appears when at least one Management PVC is defined for the node.

Possible SettingsDisable, Warm, AuthFail, Both Default Setting: Both

Determines whether SNMP trap messages for warmStart and/or authenticationFailure events are sent to the currently configured trap manager(s). An authenticationFailure trap indicates that the unit is the addressee of an SNMP protocol message, or an incoming ISDN call is not properly authenticated.

Disable – Does not send trap messages for these events.

Warm – Sends trap messages for warmStart events only.

AuthFail – Sends trap messages for authenticationFailure events only.

Both – Sends trap messages for both warmStart and authenticationFailure events.

Initial Route Destination · General Traps

Page 127 of the Paradyne 9623 user manual — Table 3-36. SNMP Traps and Trap Dial-Out Options (3 of 6)
Page 127 · click to enlarge
Page 127

Table 3-36. SNMP Traps and Trap Dial-Out Options (3 of 6)

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether trap messages for enterpriseSpecific events are sent to the currently configured trap manager(s).

Enable – Sends trap messages for enterpriseSpecific events.

Disable – Does not send trap messages for enterpriseSpecific events.

Possible SettingsDisable, Up, Down, Both Default Setting: Both

Determines whether SNMP linkDown or linkUp traps are sent to the currently configured trap manager(s). A linkDown trap indicates that the unit recognizes a failure in one of the interfaces. A linkUp trap indicates that the unit recognizes that one of its interfaces is active.

Use the Link Traps Interface and the DLCI Traps on Interfaces configuration options to specify which interface will monitor linkUp and linkDown traps messages.

Disable – Does not send linkDown or linkUp trap messages.

Up – Sends trap messages for linkUp events only.

Down – Sends trap messages for linkDown events only.

Both – Sends trap messages for linkUp and linkDown events.

Possible SettingsNetwork, DSX-1, T1s, Ports, DBM, All Default Setting: All

Specifies which interfaces will generate linkUp, linkDown, and enterpriseSpecific trap messages. These traps are not supported on the COM port or Modem port.

Network – Generates these trap messages on the network interface only.

DSX-1 – For applicable T1 FrameSaver units, generates these trap messages on the DSX-1 interface only.

T1s – For applicable T1 FrameSaver units, generates these trap messages for linkUp, linkDown, and enterpriseSpecific events on both the T1 network and DSX-1 interfaces.

Ports – Generates these trap messages for linkUp, linkDown, and enterpriseSpecific events on a user data port only.

DBM – For units with an ISDN DBM installed, generates these trap messages for linkUp, linkDown, and enterpriseSpecific events on the DBM only.

All – Generates these trap messages for linkUp and enterpriseSpecific events on all interfaces, except for the COM port or modem port, that are applicable to the FrameSaver model.

Enterprise Specific Traps · Link Traps · Link Traps Interfaces

Page 128 of the Paradyne 9623 user manual — Table 3-36. SNMP Traps and Trap Dial-Out Options (4 of 6)
Page 128 · click to enlarge
Page 128

Table 3-36. SNMP Traps and Trap Dial-Out Options (4 of 6)

DLCI Traps on Interfaces – Interface Selection Field

Possible SettingsNetwork, Ports, DBM, All, None Default Setting: All

Specifies which interfaces will generate linkUp and linkDown trap messages for individual DLCIs. These traps are only supported on the frame relay interfaces.

Network – Generates these trap messages on DLCIs for the network interface only.

Ports – Generates these trap messages for DLCIs on a user data port only.

DBM – For units with an ISDN DBM installed, generates trap messages on DLCIs for the DBM only.

All – Generates these trap messages on all frame relay interfaces.

None – No DLCI trap messages are generated.

DLCI Traps on Interfaces – Filter Selection Field

Possible SettingsNormal, Filter Default Setting: Normal

Controls whether the traps on the interfaces specified in the DLCI Traps on Interfaces configuration option are sent regardless of their cause.

Normal – Generates trap messages specified by DLCI Traps on Interfaces regardless of cause.

Filter – Prevents traps from being generated for the interfaces specified by DLCI Traps on Interfaces if their cause is the loss of the interface connection or LMI.

Possible SettingsEnable, Disable Default Setting: Enable

Specifies whether remote monitoring traps are sent to the currently configured trap manager(s). RMON traps are typically sent as a result of the Alarms and Events Groups of RMON1 when a selected variable’s configured threshold is exceeded.

Enable – Sends trap messages when set thresholds are exceeded.

Disable – Does not send trap messages when set thresholds are exceeded.

ISDN Dial Control Traps

Possible SettingsEnable, Disable Default Setting: Disable

Controls whether dialCtlPeerCallSetup and dialCtlPeerCallInformation events send trap messages to the currently configured SNMP trap manager(s). Use this feature when peer-to-peer (nearest neighbor) calling is desired.

Display Conditions – This option only appears when an ISDN DBM is installed.

Enable – Sends trap messages.

Disable – Does not send trap messages.

RMON Traps

Page 129 of the Paradyne 9623 user manual — Table 3-36. SNMP Traps and Trap Dial-Out Options (5 of 6)
Page 129 · click to enlarge
Page 129

Table 3-36. SNMP Traps and Trap Dial-Out Options (5 of 6)

Possible SettingsEnable, Disable Default Setting: Disable

Controls whether SNMP trap messages initiate a call automatically. If the call cannot be completed and the Call Retry option is set to Enable, the SNMP trap message is held (queued) until the call completes to either the Alarm or alternate directory.

Enable – Automatically calls the phone number contained in the Control menu’s Modem Call Directories, Directory Number A (Alarm).

Disable – Automatic calls will not be initiated. Traps sent to the modem are held until a dial-in connection is established.

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether the internal modem disconnects after the SNMP trap message has been sent. This configuration option only applies to modem connections initiated as a result of sending the SNMP trap message.

Enable – Disconnects the call after sending an SNMP trap message(s).

Disable – Does not disconnect the call and holds the line until it is disconnected manually or by the remote modem. This allows the NMS to poll the FrameSaver unit for more information after receiving an SNMP trap.

Possible SettingsEnable, Disable Default Setting: Disable

Controls whether an incomplete call (busy, no answer, etc.) is retried when an SNMP trap message is sent to the modem port.

If an Alternate Dial-Out Directory is specified, the alarm directory’s telephone number is called first. If the call cannot be completed, then the alternate directory’s telephone number is called (see the Control menu’s Modem Call Directories).

Enable – Attempts to retry the call, up to one time per SNMP trap message, with a delay between the retry. The delay is specified by the Dial-Out Delay Time (Min) configuration option.

Disable – Does not retry an incomplete call.

Dial-Out Delay TIme (Min)

Possible Settings1 – 10 Default Setting: 5

Specifies the amount of time between call retries when an SNMP trap message is sent; the wait between call attempts (see the Call Retry option).

1. 10 – Sets the number of minutes for the delay between call retry attempts.

Trap Dial-Out · Trap Disconnect · Call Retry

Page 130 of the Paradyne 9623 user manual — Table 3-36. SNMP Traps and Trap Dial-Out Options (6 of 6)
Page 130 · click to enlarge
Page 130

Table 3-36. SNMP Traps and Trap Dial-Out Options (6 of 6)

Possible SettingsNone, 1 – 5 Default Setting: None

Specifies whether an incomplete call (busy, or no answer, etc.) resulting from an attempt to send an SNMP trap message is retried using an alternate telephone number. Up to 5 alternate call directories can be set up, but only one at a time can be used.

When Call Retry is enabled, the alarm directory’s telephone number is called first. If the call cannot be completed after one additional try, then the specified alternate directory’s telephone number is called.

None – Does not dial-out using one of the alternate directory telephone numbers.

1. 5 – Specifies the call directory containing the telephone number to call if a call cannot be completed using the telephone number in the alarm directory (Directory Number A in the Control menu’s Modem Call Directories), inclusive.
Possible SettingsEnable, Disable Default Setting: Enable

Determines whether a Latency Threshold Alarm causes the generation of a Latency Threshold Exceeded Trap.

Enable – Sends trap messages for Latency Threshold Alarm events.

Disable – Does not send trap messages for Latency Threshold Alarm events.

IP SLV Availability Traps

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether a Path Unavailability condition causes the generation of an IP SLV Availability Trap.

Enable – Sends trap messages for Path Unavailability events.

Disable – Does not send trap messages for Path Unavailability events.

Alternate Dial-Out Directory · Latency Traps

Page 131 of the Paradyne 9623 user manual — Table 3-37. Ethernet Management Options (1 of 2)
Page 131 · click to enlarge
Page 131

Configuring Ethernet Management

Select Ethernet Management from the Management and Communication menu, or Ethernet Management Options Screen from the Easy Install screen, to configure the Ethernet port (see Table 3-37, Ethernet Management Options).

Main Menu→Configuration→Management and Communication→ Ethernet Management

Main Menu→Easy Install→Ethernet Management Options Screen

Table 3-37. Ethernet Management Options (1 of 2)

Possible SettingsEnable, Disable Default Setting: Disable

Determines whether the Ethernet port is being used and can be configured.

Enable – The port is active. It can receive Version 2 or IEEE 802.3 MAC frames and transmit Version 2 MAC frames only. When the Ethernet port is enabled, the Would you like to set the Node’s IP Destination to Ethernet? prompt is displayed.

If you select Yes, the Default IP Destination (see Table 3-31, Node IP Options) is

automatically changed to Ethernet, so the Ethernet port’s Default Gateway Address is used for packets that do not have a route. This is required when the NMS is on a different subnet than the unit.

If you select No, the COM port or a PVC will be used for packets without a route.

Disable – The port is not active. When the port is disabled, the following will occur:

No alarms or traps configured for the port will be generated.

All port uses that refer to the Ethernet port, like the Default IP Destination and Initial

Route Destination, will be reset to their default values (see Table 3-31, Node IP Options, and Table 3-36, SNMP Traps and Trap Dial-Out Options).

Possible Settings001.000.000.000 – 223.255.255.255, Clear Default Setting: Clear (000.000.000.000)

Specifies the IP address needed to access the Ethernet port.

001.000.000.000 – 223.255.255.255 – Shows the IP address for the port, which can be viewed or edited.

Clear – Fills the IP address with zeros.

Possible Settings000.000.000.000 – 255.255.255.255, Clear Default Setting: 000.000.000.000

Specifies the subnet mask associated with the IP address that is needed to access the Ethernet port.

000.000.000.000 – 255.255.255.255 – Set the Ethernet port’s subnet mask. The range for each byte is 000 to 255.

Clear – Fills the subnet mask associated with the IP address with zeros.

Interface Status · IP Address · Subnet Mask

Page 132 of the Paradyne 9623 user manual — Table 3-37. Ethernet Management Options (2 of 2)
Page 132 · click to enlarge
Page 132

Table 3-37. Ethernet Management Options (2 of 2)

Possible Settings001.000.000.000 – 223.255.255.255, Clear Default Setting: Clear (000.000.000.000)

Specifies the IP address for the port’s default gateway. It is used for packets that do not have a route.

001.000.000.000 – 223.255.255.255 – Shows the IP address for the port, which can be viewed or edited (i.e., a router on the LAN).

Clear – Fills the default gateway’s IP address with zeros.

Possible SettingsEnable, Disable Default Setting: Disable

Determines whether the FrameSaver unit will use the Proxy ARP (Address Resolution Protocol) technique, acting as the gateway to other FrameSaver devices in its management network when there is an ARP request for a device not on the Ethernet.

Enable – Proxy ARP is enabled on the port so the FrameSaver unit will act as an agent for or gateway to other units in its management network. Using this technique, the FrameSaver unit returns its own MAC (Media Access Control) address in response to ARP requests when it recognizes that the destination IP address is in its subnet, but the device sending the ARP request is in another network. Packets sent to the FrameSaver unit’s gateway address are forwarded to the appropriate device.

Disable – The Proxy ARP technique will not be used by the unit; it will not act as an agent for other devices in its network.

Default Gateway Address · Proxy ARP

Page 133 of the Paradyne 9623 user manual — Table 3-38. Communication Port Options (1 of 5)
Page 133 · click to enlarge
Page 133

Configuring the Communication Port

Select Communication Port from the Management and Communication menu to display or change the communication port configuration options (see Table 3-38, Communication Port Options).

Main Menu→Configuration→Management and Communication→ Communication Port

Table 3-38. Communication Port Options (1 of 5)

Possible SettingsTerminal, Net Link, Modem PassThru Default Setting: Terminal

Assigns a specific use to the COM port.

Terminal – The COM port is used for the asynchronous terminal connection.

Net Link – The COM port is the network communications link to the IP network or IP device port. You cannot change Port Use to Net Link when the Modem PassThru feature is enabled. When you try, the Cannot change Port Use – Modem PassThru is enabled message is displayed.

Modem PassThru – Available to the FrameSaver SLV 9626 only, the COM port is connected to the router’s auxiliary (AUX) or console port so the router can be accessed via a dial-up connection to the unit. When this feature is active, a logical connection between the unit’s modem and COM ports is made, and data received over the modem port is transmitted out the COM port to the router’s AUX or console port. When an escape sequence (minus, minus, minus, with a minimum of 50 ms between each) is detected, the FrameSaver unit switches back to normal user interface operation.

Possible Settings9.6, 14.4, 19.2, 28.8, 38.4, 57.6, 115.2 Default Setting: 19.2

Specifies the rate for the COM port in kilobits per second.

9.6 – 115.2 Kbps – Sets the communication port speed.

Possible Settings7, 8 Default Setting: 8

Specifies the number of bits needed to represent one character.

7. Sets the character length to seven bits.
8. Sets the character length to eight bits. Use this setting if using the COM port as the network communication link.

Port Use · Data Rate (Kbps) · Character Length

Page 134 of the Paradyne 9623 user manual — Table 3-38. Communication Port Options (2 of 5)
Page 134 · click to enlarge
Page 134

Table 3-38. Communication Port Options (2 of 5)

Possible SettingsNone, Even, Odd Default Setting: None

Provides a method of checking the accuracy of binary numbers for the COM port. A parity bit is added to the data to make the “1” bits of each character add up to either an odd or even number. Each character of transmitted data is approved as error-free if the “1” bits add up to an odd or even number as specified by this configuration option.

None – Provides no parity.

Even – Makes the sum of all 1 bits and its corresponding parity bit always even.

Odd – Makes the sum of all 1 bits and its corresponding parity bit always odd.

Possible Settings1, 2 Default Setting: 1

Determines the number of stop bits used for the COM port.

1. Provides one stop bit.
2. Provides two stop bits.
Possible SettingsDisable, DTR Default Setting: Disable

Specifies whether DTR is used.

Display Conditions – This option does not apply to the FrameSaver SLV Router.

Disable – Treats control leads as standard operation.

DTR – Ignores DTR. This may be necessary when connecting to some PAD devices.

Possible SettingsEnable, Disable Default Setting: Disable

Determines whether a user ID and password (referred to as the login) is required in order to log on to the asynchronous terminal connected to the COM port.

Display Conditions – This option only appears when Port Use is set to Terminal.

Enable – Requires a login to access the menu-driven user interface.

Disable – Does not requires a login.

Show 4 more labels / short text on this page
Parity · Stop Bits · Ignore Control Leads · Login Required
Page 135 of the Paradyne 9623 user manual — Table 3-38. Communication Port Options (3 of 5)
Page 135 · click to enlarge
Page 135

Table 3-38. Communication Port Options (3 of 5)

Possible SettingsLevel-1, Level-2, Level-3 Default Setting: Level-1

Specifies level of user access privilege for an asynchronous terminal connected to the COM port. If a login is required for the port, the effective access level is determined by the user’s access level. When a login is not required, the effective access level is determined by this option.

Display Conditions – This option only appears when Port Use is set to Terminal.

Level-1 – Allows full access and control of the device including monitoring, diagnostics, and configuration. The user can add, change, and display configuration options, and perform device testing.

CAUTION: Before changing the communication port’s access level to Level-2 or 3, make sure that either Telnet Session Access Level or the Modem Port’s Port Access Level is set top Level-1 and at least one Login ID is set to Level-1. Otherwise, access will be lost. If this occurs, you must reset the unit to the factory defaults and begin the configuration process again.

Level-2 – Allows limited access and control of the device. The user can monitor and perform diagnostics, display status and configuration option information.

Level-3 – Allows limited access with monitoring control only. The user can monitor and display status and configuration screens only.

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether a user session is disconnected after a specified time of inactivity (no keyboard activity).

Display Conditions – This option only appears when Port Use is set to Terminal.

Enable – Disconnects user session after the specified time of inactivity.

Disable – Does not disconnect user session.

Possible Settings1 – 60 Default Setting: 10

Specifies the number of minutes of inactivity that can elapse before the session is disconnected.

Display Conditions – This option only appears when Port Use is set to Terminal.

1. 60 – Sets the time from 1 to 60 minutes (inclusive).

Port Access Level · Inactivity Timeout · Disconnect Time (Minutes)

Page 136 of the Paradyne 9623 user manual — RIP
Page 136 · click to enlarge
Page 136

Table 3-38. Communication Port Options (4 of 5)

Possible Settings001.000.000.000 – 223.255.255.255, Clear Default Setting: Clear (000.000.000.000)

Specifies a unique IP address for accessing the unit via the COM port. Only in effect when the COM port is configured as a network communication link (Port Use option is set to Net Link).

Display Conditions – This option only appears when Port Use is set to Net Link.

001.000.000.000 – 223.255.255.255 – Shows the IP address for the COM port, which you can view or edit.

Clear – Clears the IP address for the COM port and fills the address with zeros. When the IP Address is all zeros, the COM port uses the Node IP Address if one has been configured.

Possible Settings000.000.000.000 – 255.255.255.255, Clear Default Setting: 000.000.000.000

Specifies the subnet mask needed to access the unit. Only in effect when the COM port is configured as a network communication link (Port Use option is set to Net Link).

Display Conditions – This option only appears when Port Use is set to Net Link.

000.000.000.000 – 255.255.255.255 – Shows the subnet mask for the COM port, which you can view or edit.

Clear – Clears the subnet mask for the COM port and fills the address with zeros. When the node subnet mask is all zeros, the IP protocol creates a default subnet mask based upon the class of the IP address: Class A: 255.000.000.000, Class B: 255.255.000.000, or Class C: 255.255.255.000.

RIP

Possible SettingsNone, Standard_out Default Setting: None

Specifies which Routing Information Protocol (RIP) is used to enable routing of management data between devices.

Display Conditions – This option only appears when Port Use is set to Net Link.

None – No routing is used.

Standard_out – The device will send standard RIP messages to communicate routing information about other FrameSaver units in the network. Standard RIP messages received on this link are ignored.

To create this management interface, make sure that Node or COM port IP Information has been set up (see Configuring Node IP Information on page 3-78).

IP Address · Subnet Mask

Page 137 of the Paradyne 9623 user manual — Table 3-39. Modem Port Options (1 of 4)
Page 137 · click to enlarge
Page 137

Table 3-38. Communication Port Options (5 of 5)

Possible SettingsPPP, SLIP Default Setting: PPP

Specifies the link-layer protocol to be used. Only in effect when the COM port is configured as a network communication link (Port Use option is set to Net Link).

Display Conditions – This option only appears when Port Use is set to Net Link.

PPP – Point-to-Point Protocol.

SLIP – Serial-Line Internet Protocol.

Configuring the Modem Port

Select Modem Port from the Management and Communication menu to configure the modem port (seeTable 3-39, Modem Port Options).

Main Menu→Configuration→Management and Communication→ Modem Port

Table 3-39. Modem Port Options (1 of 4)

Possible SettingsTerminal, Net Link Default Setting: Terminal

Assigns a specific use to the modem port.

Terminal – The modem port is used for the asynchronous terminal connection.

Net Link – The modem port is a network communications link to the IP network. You cannot change Port Use to Net Link when the Modem PassThru feature is enabled. When you try, the Cannot change Port Use – Modem PassThru is enabled message is displayed. See the FrameSaver SLV Operations Guide for more information about Modem PassThru operation.

Possible SettingsEnable, Disable Default Setting: Enable

Controls whether external devices can dial-in to the system through the internal modem. This allows dial-in access by a remote terminal when Port Use is set to Terminal. When Port Use is set to Net Link, Dial-In Access must be set to Enable to allow an external NMS to dial in to the device.

Enable – Dial-in access is allowed. Incoming calls are answered.

Disable – Dial-in access is not allowed. Incoming calls are not answered. You cannot disable Dial-In Access when the Modem PassThru feature is enabled. When you try, the Cannot change Dial-In Access when Modem PassThru is enabled message is displayed. See the FrameSaver SLV Operations Guide for more information about Modem PassThru operation.

Link Protocol · Port Use · Dial-In Access

Page 138 of the Paradyne 9623 user manual — Table 3-39. Modem Port Options (2 of 4)
Page 138 · click to enlarge
Page 138

Table 3-39. Modem Port Options (2 of 4)

Possible SettingsEnable, Disable Default Setting: Disable

Determines whether a user ID and password (referred to as the login) is required in order to log on to the asynchronous terminal connected to the modem port.

Display Conditions – This option only appears when Port Use is set to Terminal.

Enable – Requires a login to access the menu-driven user interface.

Disable – Does not require a login.

Possible SettingsLevel-1, Level-2, Level-3 Default Setting: Level-1

Specifies the level of user access privilege for an asynchronous terminal connected to the modem port.

Display Conditions – This option only appears when Port Use is set to Terminal.

Level-1 – Allows full access and control of the device including monitoring, diagnostics, and configuration. The user can add, change, and display configuration options, save, and perform device testing. If Login Required is set to Enable, the effective access level is determined by the user’s access level. Otherwise, the access level is 1.

CAUTION: Before changing the modem port’s access level to Level-2 or 3, make sure that either Telnet Session Access Level or the communications port’s Port Access Level is set to Level-1 and at least one Login ID are set to Level-1. Otherwise, access will be lost. If this occurs, you must reset the unit to the factory defaults and begin the configuration process again.

Level-2 – Allows limited access and control of the device. The user can monitor and perform diagnostics, display status and configuration option information. If Login Required is set to Enable, the effective access level is 2 for User ID access levels of 1 or 2. User IDs set to access Level-3 have only Level-3 access.

Level-3 – Allows limited access with monitoring control only. The user can only display and monitor status and configuration screens. If Login Required is set to Enable, the effective access level is 3 for all user IDs.

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether a user session is disconnected after a specified time of inactivity (no keyboard activity).

Display Conditions – This option only appears when Port Use is set to Terminal.

Enable – Disconnects the user session after the specified time of inactivity.

Disable – Does not disconnect the user session.

Login Required · Port Access Level · Inactivity Timeout

Page 139 of the Paradyne 9623 user manual — Table 3-39. Modem Port Options (3 of 4)
Page 139 · click to enlarge
Page 139

Table 3-39. Modem Port Options (3 of 4)

Possible Settings1 – 60 Default Setting: 10

Determines the amount of lapsed time before disconnecting a user session in minutes.

Display Conditions – This option only appears when:

Port Use is set to Terminal.

Inactivity Timeout is set to Enable.

1. 60 – Sets the number of minutes allowed before the modem disconnects.
Possible Settings001.000.000.000 – 223.255.255.255, Clear Default Setting: Clear (000.000.000.000)

Specifies a unique IP address for accessing the system via the modem port. This option is only in effect when the modem port is configured as a network communication link.

Display Conditions – This option only appears when Port Use is set to Net Link.

001.000.000.000 – 223.255.255.255 – Shows the IP address for the modem port, which you can view or edit.

Clear – Clears the IP address for the modem port and fills the address with zeros (i.e., 000.000.000.000). When the IP Address is all zeros, the modem port uses the Node IP Address if one has been configured.

Possible Settings000.000.000.000 – 255.255.255.255, Clear Default Setting: 000.000.000.000

Specifies the subnet mask needed to access the system. This option is only in effect when the modem port is configured as a network communication link.

Display Conditions – This option only appears when Port Use is set to Net Link.

000.000.000.000 – 255.255.255.255 – Shows the subnet mask for the modem port, which you can view or edit.

Clear – Clears the subnet mask for the COM port and fills the address with zeros. When the node subnet mask is all zeros, the IP protocol creates a default subnet mask based upon the class of the IP address: Class A: 255.000.000.000, Class B: 255.255.000.000, or Class C: 255.255.255.000.

Possible SettingsPPP, SLIP Default Setting: PPP

Specifies the link-layer protocol to be used. This option is only in effect when the modem port is configured as a network communication link.

Display Conditions – This option only appears when Port Use is set to Net Link.

PPP – Point-to-Point Protocol.

SLIP – Serial-Line Internet Protocol.

Show 4 more labels / short text on this page
Disconnect Time (Minutes) · IP Address · Subnet Mask · Link Protocol
Page 140 of the Paradyne 9623 user manual — Table 3-39. Modem Port Options (4 of 4)
Page 140 · click to enlarge
Page 140

Table 3-39. Modem Port Options (4 of 4)

Possible Settings001.000.000.000 – 223.255.255.255, Clear Default Setting: Clear (000.000.000.000)

Specifies the alternate IP address for the modem port. If this configuration option is not configured (i.e., it is zero), the modem port’s primary IP address is used when the alternate telephone directory is used for dial-out traps.

Display Conditions – This option only appears when Port Use is set to Net Link.

001.000.000.000 – 223.255.255.255 – Shows the modem’s alternate IP address, which you can view or edit.

Clear – Clears the alternate IP address for the modem port and fills the address with zeros.

Possible Settings000.000.000.000 – 255.255.255.255, Clear Default Setting: 000.000.000.000

Specifies the alternate subnet mask needed to access the unit. Only in effect when the modem port is configured as a network communication link.

Display Conditions – This option only appears when Port Use is set to Net Link.

000.000.000.000 – 255.255.255.255 – Shows the subnet mask for the modem port, which you can view or edit.

Clear – Clears the subnet mask for the modem port and fills the address with zeros. When the node subnet mask is all zeros, the IP protocol creates a default subnet mask based upon the class of the IP address: Class A: 255.000.000.000, Class B: 255.255.000.000, or Class C: 255.255.255.000.

Alternate IP Address · Alternate Subnet Mask

Page 141 of the Paradyne 9623 user manual — Table 3-40. Auto Backup Criteria Options (1 of 2)
Page 141 · click to enlarge
Page 141

Configuring the Criteria for Automatic Backup

For units with an ISDN DBM, follow this menu selection sequence to specify whether and when automatic backup is allowed, and to configure timers that will control and terminate backup, or set delays (see Table 3-40, Auto Backup Criteria Options).

Main Menu→Configuration→Auto Backup Criteria

Table 3-40. Auto Backup Criteria Options (1 of 2)

Possible SettingsEnable, Disable Default Setting: Disable

Determines whether backup for the access unit is automatically performed when the primary physical link or LMI, or a DLCI on a PVC connection fails, or when latency is exceeded.

When enabled, the access unit automatically enables the Alternate Link configuration option, and establishes an alternate DLCI and EDLCI, rerouting traffic over the backup interface. (See Table 3-32, Management PVC Options, to configure the alternate DLCI and alternate EDLCI.)

Enable – Reroutes traffic over the backup (alternate) interface.

Disable – Does not reroute traffic over the backup interface.

DLCI Down Backup Activation Delay (sec)

Possible Settings0 – 3600 Default Setting: 0

Specifies the number of seconds the unit will wait once a DLCI is declared down before it initiates backup. A DLCI is declared down when the DLCI changes to Inactive status in an LMI response, or when there is an LMI or physical link failure. When a delay is configured, the unit is more tolerant of network glitches, or repeated short outages, before going into backup, minimizing bouncing between network and backup services.

0. 3600 – Specifies the amount of time for the delay.

DLCI Down Backup Activation Transition Threshold

Possible Settings1 – 10 Default Setting: 1

Specifies how many times a primary destination DLCI transitions up or down during the DLCI Down Backup Activation Delay period before the unit initiates backup, provided the DLCI is active when the delay period ends.

1. 10 – Specifies the number of transitions allowed between Active and Inactive status.

Backup Restoration Delay (sec)

Possible Settings0 – 3600 Default Setting: 0

Specifies the number of seconds the unit will wait after all backup alarm conditions have cleared for a primary destination DLCI before the backup connection is terminated.

0. 3600 – Specifies the amount of time for the delay.

Auto Backup

Page 142 of the Paradyne 9623 user manual — Table 3-40. Auto Backup Criteria Options (2 of 2)
Page 142 · click to enlarge
Page 142

Table 3-40. Auto Backup Criteria Options (2 of 2)

When Auto Backup Allowed

Possible SettingsAlways, Restrict Default Setting: Always

Determines when backup for the access unit is allowed to occur.

Always – No restrictions on backup.

Restrict – Backup is restricted to the day and time selected in the following configuration options. Use this selection when the importance of the data that you are backing up is day/time dependent.

Backup AllowedDay From nn:nn
Possible Settings00:00 – 23:00, None Default Setting: 00:00

Specifies the time that Auto Backup can begin for a selected day of the week in increments of 1 hour. Day is Monday through Sunday.

00:00 – 23:00 – Specifies the time of day that Auto Backup will start for this particular day.

None – Auto Backup cannot occur on this day.

Backup AllowedDay To nn:nn
Possible Settings00:00 – 24:00 Default Setting: 24:00

Specifies the time that Auto Backup must end occurring for the selected day of the week in increments of 1 hour.

Display Conditions – This option only appears if a start time was specified.

00:00 – 24:00 – Specifies the time of day that Auto Backup will stop for this particular day.

Page 143 of the Paradyne 9623 user manual — Feature-Specific Configuration
Page 143 · click to enlarge
Page 143

Feature-Specific Configuration

This chapter includes the following:

Setting Up an External Modem on page 4-2

Setting Up an Internal Modem on page 4-3

— Setting Up Call Directories for Trap Dial-Out

— Setting Up to Use the Modem PassThru Feature

Setting Up Dial Backup on page 4-5

— Setting Up the DBM Physical Interface

— Setting Up Automatic Backup Configuration

— Modifying ISDN Link Profiles

— Restricting Automatic Backup and Configuring Backup Timers

— Configuring the DBM Interface to Send SNMP Traps

— Assigning DLCIs to a Backup Group

PVC Backup Over the Network Interface on page 4-12

Setting Up Back-to-Back Operation on page 4-12

— Changing Operating Mode

Page 144 of the Paradyne 9623 user manual — AT &C0 &D2 &S0 &R1 \D0 S0=1
Page 144 · click to enlarge
Page 144
4. Feature-Specific Configuration

Setting Up an External Modem

A standard EIA-232-D crossover cable can be used to connect the COM port to an external modem. The external modem must be configured so it is compatible with the FrameSaver unit.

Procedure

To configure an external modem:

1. Connect the crossover cable to the external modem.
2. Enable auto-answer on your modem, and configure it to use the following LSD, DSR, CTS, RTS, and DTR control leads.

See the table below for AT D0 command strings. Use the following command string:

AT &C0 &D2 &S0 &R1 \D0 S0=1

AT Command String To configure the modem to . . .

&C0 Force LSD on.

&D2 Drop the connection when the unit drops DTR.

&S0 Force DSR on.

&R1 Ignore RTS.

\D0 Force CTS on.

S0=1 Automatically answer incoming calls.

Page 145 of the Paradyne 9623 user manual — Procedure
Page 145 · click to enlarge
Page 145
4. Feature-Specific Configuration

Setting Up an Internal Modem

Models 9126, 9128, 9520, 9520-ILM, 9626, and 9820-45M have an internal modem for dial-in access to the menu-driven user interface, as well as dial-out capability when an SNMP trap is generated. When the modem will be used to dial out, Modem Directory phone numbers need to be set up. Otherwise, simply configure or change dial-in access to the unit.

The modem port is already configured for connection to an asynchronous terminal and dial-in access, with Port Use set to Terminal. However, additional changes may be needed (see Table 3-39, Modem Port Options, in Chapter 3, Configuration Options).

Main Menu→Configuration→Management and Communication→ Modem Port

For dial-in access to the menu-driven user interface via Telnet, make sure Port Use is set to Net Link, the IP address and subnet mask are entered if they are different from the node’s, and that the Link Protocol is correct.

For dial-in access to the router connected to the unit’s COM port, make sure the Communication Port’s Port Use option is set to Modem PassThru.

See Setting Up Call Directories for Trap Dial-Out on page 4-3, when trap dial-out is desired. See Setting Up to Use the Modem PassThru Feature on page 4-4, if this feature is desired. See the FrameSaver SLV Operations Guide for additional information.

Setting Up Call Directories for Trap Dial-Out

Procedure

1. Set up directory phone numbers.

Main Menu→Control→Modem Call Directories

2. Select Directory Number A (for Alarm).
3. Enter the phone number(s).

Valid characters include . . . For . . .

ASCII text Entering the phone number.

Space, underscore ( _ ), and dash (–)

Readability characters.

Comma (,) Readability character for a 2-second pause.

B Blind dialing.

P Pulse dialing, unless B is specified.

T Tone dialing, unless B is specified.

W Wait for dial tone.

Page 146 of the Paradyne 9623 user manual — Procedure
Page 146 · click to enlarge
Page 146
4. Feature-Specific Configuration
4. Save the phone number(s).

Setting Up to Use the Modem PassThru Feature

Dial-in access to the router is possible via the Modem PassThru feature, also known as the Router Assist feature. The FrameSaver unit’s COM port must be connected to the router’s auxiliary (AUX) or console port, and the COM port must be configured for this use.

When this feature is set up and active, a logical connection between the unit’s modem and COM ports is made, and data received over the modem port is transmitted out the COM port to the router’s AUX or console port. When an escape sequence (minus, minus, minus, with a minimum of 50 ms between each) is detected, the FrameSaver unit switches back to normal user interface operation.

See the FrameSaver SLV Technical Description for cable information.

Procedure

1. Configure the COM port to use Modem PassThru.

Main Menu→Configuration→Management and Communication→ Communication Port

2. Set Port Use to Modem PassThru.
3. Save the configuration.
Page 147 of the Paradyne 9623 user manual — Procedure
Page 147 · click to enlarge
Page 147
4. Feature-Specific Configuration

Setting Up Dial Backup

When configuring units with ISDN backup capability, the following guidelines apply:

Central site configuration guidelines:

— Set up the ISDN DBM physical interface.

— If a BRI DBM, change the Automatic Backup Configuration to Multi_Site_Backup. (A PRI DBM is already configured for multisite backup.)

— Modify the Link Profile(s) that Automatic Backup Configuration created to add a phone number.

Remote site configuration guidelines:

— Set up the ISDN DBM physical interface.

— If a PRI DBM, change the Automatic Backup Configuration to Single_Site_Backup. (A BRI DBM is already configured for single-site backup.)

— Modify the HQ_Site Link Profile that Automatic Backup Configuration created to add a phone number.

— Set the criteria by which automatic backup will take place.

Setting Up the DBM Physical Interface

Procedure

1. Configure the DBM interface.

Main Menu→Configuration→ISDN→Physical

2. Enable the interface, and enter the Service Profile IDs (SPIDs) and local phone numbers.
3. Save the configuration.

See Table 3-20, ISDN BRI DBM Physical Interface Options (9126, 9626), or Table 3-21, ISDN PRI DBM Physical Interface Options (9128), in Chapter 3, Configuration Options, for configuration information.

Page 148 of the Paradyne 9623 user manual — NOTE:
Page 148 · click to enlarge
Page 148
4. Feature-Specific Configuration

Setting Up Automatic Backup Configuration

The Automatic Backup Configuration feature is used to automatically create alternate DLCI records and PVC connections on the ISDN DBM (backup) interface for current or newly discovered PVC Connections and Management PVCs.

This feature is already set up, with Single_Site_Backup as the default for units with a BRI DBM and Multi_Site_Backup for units with a PRI DBM. If the unit at the central site has a BRI DBM, change the Automatic Backup Configuration to Multi_Site_Backup, if necessary.

Main Menu→Auto-Configuration→Automatic Backup Configuration

If you select . . . Then . . .

Alternate destinations are automatically configured using a single ISDN Link Profile to backup all network PVC Connections and Management PVCs over the primary destination ISDN link.

(default for a BRI DBM)

(Used at remote sites since only one ISDN link to the central-site is needed.)

Initially, PVCs with alternate destinations are configured on the first ISDN Link Profile using the same DLCI number as the network DLCI being backed up. However, primary destination PVCs on the ISDN DBM interface are automatically updated to use a different DLCI number for the alternate destination DLCI, derived from the first SLV message received on the each network DLCI.

Alternate destinations are automatically configured using a separate ISDN Link Profile to backup each network PVC Connection and Management PVC over the ISDN interface.

(default for a PRI DBM)

(Used at central sites since multiple ISDN links are needed, one for each remote-site.)

Initially, all DLCIs are configured on the ISDN links using the same DLCI number as the network DLCI being backed up. However, primary destination PVCs on the ISDN DBM interface are automatically updated to use a different DLCI number for the alternate destination DLCI, derived from the first SLV message received on the each network DLCI.

Automatically created alternate destination Link Profiles appear as Bkupnnnn, nnnn being the DLCI number (e.g., Bkup200 would be configured for network DLCI 200).

Disabled No automatic configuration takes place on the DBM interface and no alternate destinations are created for PVCs.

NOTE:

Changes must be saved to take effect.

See Setting Up Auto-Configuration in Chapter 2, Basic Configuration, to see a screen example.

Single_Site_Backup · Multi_Site_Backup

Page 149 of the Paradyne 9623 user manual — Setting Up Automatic Backup Configuration
Page 149 · click to enlarge
Page 149
4. Feature-Specific Configuration

When the Automatic Backup Configuration setting is changed, the following prompts appear. No is the default for these prompts.

The following prompt appears . . . If you select . . .

When the . . .

No – No Auto-Configuration

Saving will cause Auto-Configuration to update and Restart. Are you sure?

Configuration setting was changed, and

updates are performed and updates due to LMI response messages are performed according to the previously saved setting.

Save was selected

Yes – The Delete All

DLCIs and PVC Connections? prompt appears.

Response to the

No – No previously configured

Delete All Alternate Destinations from PVC Connections?

Delete All DLCIs and PVC Connections? prompt was No, and

DLCIs or PVC connections are removed or changed, and newly discovered DLCIs will be configured according to the new discovery mode and automatic backup setting.

Yes – All multiplexed DLCIs,

ISDN Link Profiles (except for the first one), and PVC connections are deleted, except for management PVCs with the user data port as the primary destination and management PVCs designated as the TS Management Link.

If an alternate destination has been configured on a retained Management PVC, the alternate destination will be deleted but the primary destination will be retained.

Response to the

Yes – DLCI records are

Add Alternate Destinations to Current PVC Connections?

Delete All DLCIs and PVC Connections? prompt was No, and

configured on the ISDN link(s) and Alternate Destination information is added to current PVC connections and management PVCs.

Configuration was set to Single_Site_Backup or Multi_Site_Backup

No – No previously configured

PVC connections are changed, and newly discovered DLCIs will be configured according to the new discovery mode and automatic backup setting.

Show 4 more labels / short text on this page
Automatic Backup · Automatic Backup · Configuration was disabled · Automatic Backup
Page 150 of the Paradyne 9623 user manual — NOTE:
Page 150 · click to enlarge
Page 150
4. Feature-Specific Configuration

The following prompt appears . . . If you select . . .

When the . . .

Response to the

— No – No previously configured

Remove Alternate Destinations from PVCs and delete unused DLCI Records? prompt was Yes, and

DLCIs, ISDN Link Profiles, or PVC Connections are removed or changed, but updates due to LMI responses will be performed using the new setting.

Yes – All Alternate Destination

information will be removed from PVC Connections and Management PVCs, and all DLCIs and ISDN Link Profiles (except for the first one) used exclusively as Alternate Destinations are deleted.

Response to the

Add Alternate Destinations to Current PVC Connections?

No – No previously configured

Remove Alternate Destinations from PVCs and delete unused DLCI Records? prompt was Yes, and

PVC Connections are removed or changed, but updates due to LMI responses will be performed using the new setting.

Yes – Alternate Destination

information is configured for current DLCIs, ISDN Link Profiles, PVC Connections and Management PVCs on the ISDN DBM interface, except for the Management PVC designated as the TS Access Management Link.

Configuration was set to Single_Site_Backup or Multi_Site_Backup

NOTE:

When DLCIs, PVC connections, and management PVCs for the first ISDN Link Profile have been configured manually, it is recommended that specific discovered DLCIs, PVC connections, and management PVCs be deleted manually via the Configuration menus. Otherwise, the manual configurations will be deleted along with the automatically configured ones.

To specify when automatic backup is allowed or can occur, see Configuring the Criteria for Automatic Backup in Chapter 3, Configuration Options.

Automatic Backup · Configuration was disabled · Automatic Backup

Page 151 of the Paradyne 9623 user manual — NOTES:
Page 151 · click to enlarge
Page 151
4. Feature-Specific Configuration

Modifying ISDN Link Profiles

Once an ISDN Link Profile is configured using the Automatic Backup Configuration feature, phone numbers and Calling IDs need to be entered. FrameSaver units with ISDN backup capability can originate or answer calls, as needed, so both phone numbers and Calling IDs are needed.

Procedure

1. Select Link Profiles, then Modify.

Main Menu→Configuration→ISDN→Link Profiles

2. Add a name and phone number to the ISDN Link Profile(s) created by Automatic Backup Configuration.

— Name for the destination entered (e.g., Tampa). The default setting is HQ_Site for the first ISDN Link Profile.

— Phone numbers entered:

For Originating a Backup Call For Answering a Backup Call

Outbound and Alternate Outbound phone numbers

Inbound Calling ID1 and ID2

These are the phone numbers of units from which calls will be accepted.

Valid characters can include:

Valid characters can include:

Special characters * and #

Parentheses ( )

NOTES:

Remember to include local dial-out numbers (i.e., 9, then the number).

For every originating (outbound) phone number entered, an answering (inbound) phone number must be entered at the far end, and vice versa.

— Maximum Link Rate (Kbps) set to the appropriate speed, if necessary.

— Caller Identification Method set to Proprietary if call validation is not required. The setting must be the same at both ends of the circuit.

— An Alternate Outbound Phone Number should a call using the primary Outbound Phone Number be unsuccessful, if desired.

3. Save the configuration.

See Table 3-22, ISDN Link Profile Options, in Chapter 3, Configuration Options, for configuration information.

Numbers (0–9) · Numbers (0–9) · Spaces

Page 152 of the Paradyne 9623 user manual — Procedure
Page 152 · click to enlarge
Page 152
4. Feature-Specific Configuration

Restricting Automatic Backup and Configuring Backup Timers

You can specify when auto backup is allowed to occur. If backup is restricted and a backup is active when the allowed time for backups is over, then the backup is terminated and the data is returned to the primary data path regardless of the primary path’s condition.

You can restrict auto backup to occur only:

On certain days of the week

At certain times of the day

The following additional features can be configured:

Delays can be configured to control how long the unit will wait before initiating backup when a DLCI is declared down, and how long it will wait to restore service once the DLCI is declared operational again.

A threshold can be set to determine how many times a primary destination DLCI can transition between Active and Inactive before the unit initiates backup.

Procedure

To set the criteria and backup timers for automatic backup:

1. Enable Auto Backup.

Main Menu→Configuration→Auto-Backup Criteria

When a failure occurs, the unit automatically enables the Alternate Link and traffic is rerouted over the backup (alternate) interface.

2. Specify the amount of delay after a DLCI is declared down before backup is initiated (DLCI Down Backup Activation Delay).
3. Set the threshold for transitions of the DLCI’s status before backup is initiated (DLCI Down Backup Activation Transmission Threshold).
4. Specify the amount of delay after a DLCI is declared operation before backup is ended (Backup Restoration Delay).
5. Specify When Auto Backup Allowed – Always or Restrict. If Restrict is selected, specify the days and hours of the week during which automatic backup can take place.
6. Save the configuration.

See Table 3-40, Auto Backup Criteria Options, in Chapter 3, Configuration Options, for configuration information.

Page 153 of the Paradyne 9623 user manual — Assigning DLCIs to a Backup Group
Page 153 · click to enlarge
Page 153
4. Feature-Specific Configuration

Configuring the DBM Interface to Send SNMP Traps

The ISDN DBM interface can be specified as an interface that monitors and generates SNMP traps:

Main Menu→Configuration→Management and Communications→ SNMP Traps

The configuration options for doing this include:

Link Trap Interfaces

DLCI Traps on Interfaces

ISDN Dial Control Traps

When DBM is selected, trap messages are generated for linkUp and linkDown events on DLCIs and frame relay links for the originating DBM interface only. For peer-to-peer backup, backing up to a neighboring node like a regional node, dial control traps can be sent to trap manager(s).

See Table 3-36, SNMP Traps and Trap Dial-Out Options, in Chapter 3, Configuration Options, for configuration information.

Assigning DLCIs to a Backup Group

DLCIs can be assigned to a Backup Group to reduce backup charges when redundant PVCs have been configured. This feature prevents backup as long as any DLCI in the group is operational.

Backup is not initiated as long as one DLCI in the group is operational.

Backup is terminated as soon as one DLCI in the group becomes operational.

See Table 3-26, DLCI Record Options, in Chapter 3, Configuration Options, for configuration information.

Page 154 of the Paradyne 9623 user manual — Procedure
Page 154 · click to enlarge
Page 154
4. Feature-Specific Configuration

PVC Backup Over the Network Interface

Generally, backup can be performed on the network interface’s frame relay link using a backup PVC, as well on an ISDN link; the unit does not have to have the ISDN DBM feature.

In this case, create a DLCI Record on the network interface that will be used for backup, then modify the PVC Connections or Management PVCs to add the alternate destination.

Setting Up Back-to-Back Operation

Using this special feature, you can set up two FrameSaver units that are connected back-to-back without frame relay switches between them, as in a test bench setup using a crossover cable.

Changing Operating Mode

When setting up back-to-back operation:

One unit must be configured for Standard operation, which is the setting for normal operation.

The other unit must be configured for Back-to-Back operation so it presents the network side of the UNI (user-network interface).

Only one of the units will have its operating mode changed.

Procedure

To set up back-to-back operation:

1. On the unit to be configured for Back-to-Back operation, manually configure DLCIs; DLCIs should be configured before connecting the two units.
2. Access the Change Operating Mode screen.

Main Menu→Control→Change Operating Mode

3. Select Back-to-Back Operation, and respond Yes to the Are you sure? prompt.
4. Save the change.

Procedure

To return the unit to normal operation:

1. Return to the Change Operating Mode screen and switch back to Standard Operation.
2. Respond Yes to the prompt and save the change. The units can be reconnected to a standard frame relay network.
Page 155 of the Paradyne 9623 user manual — PVC Backup Over the Network Interface
Page 155 · click to enlarge
Page 155
4. Feature-Specific Configuration
Page 156 of the Paradyne 9623 user manual — PVC Backup Over the Network Interface
Page 156 · click to enlarge
Page 156
4. Feature-Specific Configuration
Page 158 of the Paradyne 9623 user manual — D
Page 158 · click to enlarge
Page 158

auto-configuration, 4-7 automatic backup configuration, 4-7 configuration options, 1-5 changing operating mode, 4-12 Channel, 2-10, 3-25 Character

ATM, 3-71 Code Point definitions, 3-10 DBM, 3-44

interface to send traps, 4-11 DLCI records manually, 3-64 frame relay options, 3-63 modem port, 3-105 network interface, 3-17 PPP options, 3-7 RIP, 2-11 router to receive RIP, 2-11 SLV options, 3-11 System options, 3-3 the system, 1-2 Control Leads

Length, 3-101 CIR, 3-65, 3-69

Records, configuring, 3-68 Circuit Identifier, 3-21–3-22, 3-47 Circuit Type (PPP), 3-63 Class of Service

Code Points, 3-10 Clearing

CTS, 3-29 DSR, 3-29–3-30 DTR, 3-34, 3-37, 3-40 Ignore, 3-102 RLSD, 3-29 RTS, 3-33, 3-38, 3-40 copyrights, A COS

cross connection assignments, 3-50 Event

LMI, 3-5, 3-62 existing information, 2-12 Clock

Invert Transmit, 3-33, 3-37, 3-39 setting system, 2-12 Source, 3-14–3-15

applying SLV measurements, 3-11 Create a Dedicated Network Management Link, 2-6 creating

Transmit, 3-33, 3-37, 3-39 ClrAllCodePoints, 3-8 Code Points, 3-10 COM port, 3-79, 3-94 Committed

new PVC connections/management links, 1-5 cross connections, 3-50 CTS, 3-29

Burst Size Bc (Bits), 3-69 Information Rate (CIR), 3-69

D

interval, 3-69 Committed Burst Size Bc, 3-66 Communication Port

Channel Loopback, 3-20, 3-24 Link Control Identifier (DLCI), 3-84, 3-86 Rate, 3-101 Data Port

user interface options, 3-101 Community Name, 3-88 Configuration

network interface options, 3-28, 3-30 physical options, 3-31 T3 physical options, 3-41 Date and Time setting, 2-12 DBM, 3-44

displaying and changing options, 1-4 menu, 1-2 option areas, 1-3 option tables, 3-1 saving options, 1-6 Scratchpad area, 1-3

configuring interface, 3-44 configuring to send traps, 4-11 DDS

Line Rate, 3-23 network interface options, 3-23 DE

Set, 3-83 Default IP Destination, 3-79 DefaultCodePoints, 3-8

IN-2 December 2002 9000-A2-GB31-00

Show 5 more labels / short text on this page
Index · changing · configuring · enforcement, 3-61 Circuit · Data
Page 159 of the Paradyne 9623 user manual — SDSL, 3-26 SHDSL, 3-27 SDSL
Page 159 · click to enlarge
Page 159

Default IP, 3-79 DLCI, 3-73–3-74 EDLCI, 3-74–3-75 Link, 3-73–3-74 dial backup, 4-5 Dial-In Access, 3-105 Dial-Out

Alcatel (NewBridge), 2-5 Nokia, 2-5 PairGain, 2-5 Paradyne, 2-5 selecting, 2-5 DSR, 3-29–3-30 DSU Latching Loopback, 3-24 DSX-1

Delay Time (Min), 3-97 Directory, 3-98 options, 3-93, 4-3 Trap, 3-97 Directory

assigning data port to time slots, 3-58 assigning time slots, 3-52 setting up, 3-42 signaling assignments, 3-54 trunk conditioning, 3-54 DTE

Alternate Dial-Out, 3-98 disabling

ILMI, 3-71 disaster recovery, 4-5, 4-12 Discard Eligible (DE), 3-83 Disconnect

port-initiated loopbacks, 3-34, 3-38, 3-40 DTR, 3-34, 3-37, 3-40

Ignore Control Leads, 3-102

Time (Minutes), 3-91, 3-103, 3-107 Discovery

E

frame relay (FR), 2-14 Frame Relay Mode

options, 2-4 using, 2-2 EDLCI, 3-73–3-75, 3-85–3-86

saving a mode change, 2-16 displaying

Destination, 3-74–3-75 Source, 3-73 EIA-530-A

configuration options, 1-4 DLCI, 3-84, 3-86

Alternate, 3-86 assigning to a Backup Group, 4-11 Destination, 3-73–3-74 Down on SLV Timeout, 3-12 IP Enabled, 3-65 Number, 3-64, 3-68 Priority, 3-67 Records, 3-64 Source, 3-72 Traps on Interfaces, 3-96 Type, 3-65, 3-69 DS0 Base Rate (PPP), 3-63 DSL

network physical interface options, 3-28 specifying port type, 2-10, 3-31, 3-36 EIR

enforcement, 3-61 Embedded DLCI, 3-73–3-75, 3-85–3-86 enabling ILMI, 3-71 Encapsulation Mode, 2-10, 3-71 entering ISDN call profiles, 3-48 entering system information, 4-3 Enterprise

Specific Traps, 3-95 Error

IDSL

LMI, 3-5, 3-61 Error Event

network interface options, 3-25 Line Rate, 2-9

Cell Delineation Threshold, 3-71 Ethernet

SDSL, 3-26 SHDSL, 3-27 SDSL

Initial Route Destination, 3-94 Management Options Screen, 2-6 Ethernet port, 3-79

network interface options, 3-26 SHDSL

default gateway address, 3-100 even parity, 3-102 Excess Burst Size, 3-66 Excess Burst Size Be (Bits), 3-70 Excessive

Line Rate, 3-27 network interface options, 3-27

Error Rate Threshold, 3-47

9000-A2-GB31-00 December 2002 IN-3

Show 5 more labels / short text on this page
Index · Destination, 3-94 · DSLAM type · Easy Install · Event
Page 160 of the Paradyne 9623 user manual — IDSL
Page 160 · click to enlarge
Page 160

Excessive Error Rate Threshold, 3-21 External

Ethernet port, 3-99 Network, 3-42 Internal

Transmit Clock, 3-33 External Transmit Clock, 3-37, 3-39

Transmit Clock, 3-33 Internal Transmit Clock, 3-37, 3-39 interoperability, DSLAM type, 2-5 Invert Internal Clock, 3-28 Invert Transmit and Received Data, 3-35 Invert Transmit Clock, 3-33, 3-37, 3-39 IP

F

assigning time slots, 3-51 configuring interface, 3-60 configuring system, 3-3 Discovery, 2-14

default destination, 3-79 node information, 3-78 Validation

saving a mode change, 2-16 DS0s Base Rate, 3-61 setting mode, 2-4 frames, 3-83 FRF.8 Encapsulation Mode, 2-10, 3-71 FTP, 3-91

NMS, 3-92 IP Address, 3-83, 3-104, 3-107

distributing to other FrameSavers, 3-76 Ethernet port, 3-99 Modem port, 3-108 NMS number, 3-92, 3-94 Node, 2-5, 3-78 validation, 3-81 IP Enabled

Login Required, 3-91 Max Transfer Rate (kbps), 3-91 Session, 3-91

G

G.991.2 Annex conformance, 3-27 Gateway Address

DLCI Type, 3-65 IP SLV

availability traps, 3-98 ISDN

options, 3-14 SNMP management

physical options, 3-44 setting up link profiles, 3-48

options, 3-88 Traps, 3-94 glossary, v

K

Keep, 3-63 Keep Alive (PPP), 3-63

H

HSSI

data port options, 3-38 network interface options, 3-30 specifying port type, 2-10, 3-39 Hunt (Line Rate Mode), 2-8, 3-26–3-27 hyperlink to more information

LADS/LDM application, 3-23 Latching Loopback, 3-24 latency

setting threshold, 3-13 traps, 3-98 Leased Line

setting mode, 2-4 Line

IDSL

Build Out (LBO), 2-7, 3-18, 3-22, 3-46 Coding Format, 2-7, 3-18, 3-42 Equalization, 3-43 Framing Format, 2-7, 3-18, 3-42, 3-45 Line Rate

network interface options, 3-25 Ignore Control Leads, 3-102 ILMI, 3-71 Inactivity Timeout, 3-91, 3-103, 3-106 Inbound Calling ID, 3-49 Initial Route Destination, 3-94 Initialize_From_Network, 3-23 Interface PPP, 3-63

DSL, 2-9 Network DSL, 2-9 SDSL, 3-26 SHDSL, 3-27 Line Rate Mode, 2-8, 3-26–3-27

IN-4 December 2002 9000-A2-GB31-00

Show 5 more labels / short text on this page
Index · Interface Status · Frame Relay · Default, 3-100 General · highlighted text, viii
Page 161 of the Paradyne 9623 user manual — M
Page 161 · click to enlarge
Page 161

Create a Dedicated Network Management, 2-6 Destination, 3-73–3-74 maximum ISDN rate, 3-49 Name, 3-48 Protocol, 3-105, 3-107 setting up ISDN profiles, 3-48 Source, 3-72 Status, 3-48 Traps, 3-95 Traps Interfaces, 3-95 TS Management, 3-80 linkUp and linkDown

changing Operating, 4-12 FRF.8 Encapsulation, 2-10, 3-71 modem

PassThru, 3-101 PassThru feature, 4-4 port

destination, 3-94 port destination, 3-79 port options, 3-105 setting up, 4-3 Monitor

CTS, 3-29 DSR, 3-29–3-30 DTR, 3-34, 3-37, 3-40 RLSD, 3-29 RTS, 3-33, 3-38, 3-40 MTU, 3-80 Multiplexed

Behavior, 3-3–3-4 Behavior (9783 and 9788), 3-5 Clearing Event (N3), 3-5, 3-62 configuring frame relay and, 3-3 Error Event (N2), 3-5, 3-61 Heartbeat (T1), 3-6, 3-62 Inbound Heartbeat (T2), 3-6, 3-62 N4 Measurement Period (T3), 3-6, 3-62 Parameters, 3-61 pass-through, 3-3 Protocol, 3-60 Status Enquiry (N1), 3-6, 3-62 local

DLCI, 3-73–3-75, 3-84–3-86 DLCI Type, 3-65, 3-69

N

N1

LMI Status Enquiry, 3-6, 3-62 N2

LMI Error Event, 3-5, 3-61 N3

external DTE loopback, 3-34, 3-38, 3-40 Login

LMI Clearing Event, 3-5, 3-62 Name, 3-82

Required, 3-90, 3-102, 3-106 Loopback

Access, 3-88–3-89 Community, 3-88 Net Link

DSU Latching, 3-24 Port (DTE) Initiated, 3-34, 3-38, 3-40

Port Use, 3-101, 3-105 NetOnly mode, 2-15 Network

M

assigning data port to time slots, 3-58 configuring the interface, 3-17 DLCI records

options, 3-77 Create a Dedicated Link, 2-6 Ethernet Options Screen, 2-6 General SNMP

options, 3-64 DSL Line Rate, 2-9 FRF.8 Encapsulation Mode, 2-10, 3-71 Initiated Data Channel Loopback, 3-36 Initiated DCLB, 3-20, 3-24 Initiated LLB, 3-19, 3-22, 3-46 Initiated PLB, 3-19, 3-46 interface

options, 3-88 MTU Size, 3-80 Outbound Priority, 3-70 PVCs, 3-82 SNMP, 3-88 troubleshooting link, 3-78 Margin Alarm Threshold (dB), SNR, 3-26 Max Port Rate, 3-32 Maximum Link Rate, 3-49 menu

configuring ATM, 3-71 configuring Circuit Records, 3-68 interface options, 3-18, 3-22–3-23 Management

Create a Dedicated Link, 2-6 physical options, 3-28, 3-30

9000-A2-GB31-00 December 2002 IN-5

Show 7 more labels / short text on this page
Index · Link · Mode · events, 3-95 LMI · Management · and Communication · Configuration, 1-2
Page 162 of the Paradyne 9623 user manual — P
Page 162 · click to enlarge
Page 162

NMS

IP Address, 3-92, 3-94 IP Validation, 3-92 SNMP security

(DTE) Initiated Loopbacks, 3-34, 3-38, 3-40 Access Level, 3-103, 3-106 assigning port to network or DSX-1 time slots, 3-58 assignment

clearing, 3-59 Base Rate, 3-32 communication

IP Address, 2-5, 3-78 IP configuration option tables, 3-78 Subnet Mask, 2-5, 3-79 Nokia DSLAM type, 2-5 NSP, 3-3 Number of

options, 3-101 Ethernet interface status, 3-99 modem

Managers, 3-92 Trap Managers, 3-93

data ports, 3-31, 3-38 Use, 3-32

O

COM port, 3-101 Modem port, 3-105 Port Type

odd parity, 3-102 operating mode

network data port, 2-8, 3-28 specifying, 3-36, 3-39

changing, 4-12 Operating Rate (9720), 3-25 organization of this document, v Outbound

network, 2-8 specifying (Easy Install), 2-10 specifying (V.35), 3-31 power spectral density (PSD), 3-28 PPP

Management Priority, 3-67 Phone Number, 3-49

alternate, 3-50 Outbound Management Priority, 3-70

behavior, 3-7 configuring interface, 3-63 configuring system options, 3-7 link protocol, 3-105, 3-107 setting mode, 2-4 Primary Clock

P

packets, 3-83 PairGain DSLAM type, 2-5 Paradyne DSLAM type, 2-5 Parity, 3-102 patents, A payload management

Source, 3-14 Primary Destination

DLCI, 3-73 EDLCI, 3-74 Link, 3-73 Primary Frame Relay Link, 3-84, 3-86 Primary Link RIP, 3-85 product-related documents, vi Profile ID (SPID), 3-44 profiles

configuration option, 3-81 enable, 3-83 Payload Scrambling, 3-71 Phone Number, 3-44–3-45 physical

data port options, 3-31 DSX-1, 3-42 ISDN options, 3-44 T3 data port options, 3-41 Policing

Caller Identification Method, 3-50 RIP, 3-85

IN-6 December 2002 9000-A2-GB31-00

Show 6 more labels / short text on this page
Index · Port · options, 3-92 Node · options, 3-105 Status · entering, 3-48 Proprietary · Traffic, 3-61
Page 163 of the Paradyne 9623 user manual — S
Page 163 · click to enlarge
Page 163

address resolution, 3-100 encapsulations, 2-10, 3-71 Link, 3-105, 3-107 LMI, 3-60 Point-to-Point (PPP), 3-105, 3-107 Routing Information (RIP), 3-85, 3-104 Serial Line

SNMP NMS

options, 3-92 selecting DSLAM type, 2-5 Send

All Ones on DSX-1 Failure, 3-43 Service, A

Profile ID (SPID), 3-44 service level

IP (SLIP), 3-105, 3-107 Simple Network Management (SNMP), 3-88 Proxy ARP, 3-100 PSD Mask, 3-28 PVC

configuring, 3-11 Service Type, 2-4 Session

backup over network interface, 4-12 connections, 3-72 Management, 3-82 name, 3-79–3-80, 3-94

Access Level, 3-90 Set DE, 3-83 setting Date and Time (system clock), 2-12 setting up

auto-configuration, 2-13 DBM, 2-16, 4-5 ISDN link profiles, 3-48 modem, 4-3 SNMP trap managers, 3-92 SHDSL

Q

quality of service, 3-67

R

network interface options, 3-27 SLIP, 3-105, 3-107 SLV

IDSL Line, 2-9 SDSL Line, 2-9, 3-26 SHDSL Line, 2-9, 3-27 Region Setting, 3-27 RFC 2474, 3-10 RfcCodePoints, 3-8 RIP, 3-104

configuring, 3-11 Delivery Ratio, 3-12 DLCI Down on Timeout, 3-12 Packet Size, 3-13 Round Trip Latency

on COM port, 3-104 using, 2-11 RLSD, 3-29 RMON

Clearing Event Threshold, 3-13 Round Trip Latency Error Threshold, 3-13 Sample Interval (secs), 3-11 Synchronization Role, 3-11 Timeout

Error Event Threshold, 3-12 Timeout Error Event Threshold, 3-12 type, 3-11 SNMP

assist feature, 4-4 independence, 3-3 RTS, 3-33, 3-38, 3-40

Management, 3-88 NMS security

S

options, 3-92 Number of Managers, 3-92 setting up Trap Managers, 3-92 Traps, 3-93

SLV Inband and Interval, 3-11 saving configuration options, 1-6 Scrambling, Cell Payload, 3-71 Scratchpad Configuration, 1-3 SDSL

setting up DBM to send, 4-11 validation, 3-81 SNR Margin

network interface options, 3-26 Secondary Clock

Threshold (dB), 3-26 Source

DLCI, 3-72 EDLCI, 3-73 Link, 3-72

9000-A2-GB31-00 December 2002 IN-7

Show 8 more labels / short text on this page
Index · Protocol · security, 1-5 · verification · Rate · Traps, 3-96 router · Sampling · Source, 3-15
Page 164 of the Paradyne 9623 user manual — U
Page 164 · click to enlarge
Page 164

spectral density (PSD), 3-28 SPID, 3-44 Standard DLCI Type, 3-69 Status

transmit, 3-23 trademarks, A Traffic Policing, 3-61 Training, A Translational Mode, 2-10, 3-71 Transmit Clock

LMI, 3-6, 3-62 Stop Bits, 3-102 Subnet Mask, 3-83, 3-99, 3-104, 3-107–3-108

Invert, 3-33, 3-37, 3-39 Source, 3-33, 3-37, 3-39 Transmit Timing, 3-19, 3-23 Transparent Mode, 2-10, 3-71 transparent operation, 2-4 Traps

Node, 2-5, 3-79 subrate

network interface options, 3-23 suggestions

user documentation, A Switch Type, 3-45 System

Dial-Out, 3-97 Disconnect, 3-97 DLCI, 3-96 Enterprise Specific, 3-95 General, 3-94 IP SLV Availability, 3-98 latency, 3-98 Link, 3-95 Link Interfaces, 3-95 Managers

Alarm Relay, 3-16 configuring options, 3-3 entering information, 2-12 Frame Relay and LMI

options, 3-3 General options, 3-14 setting the clock (date and time), 2-12

T

Number of, 3-93 RMON, 3-96 SNMP and dial-out

T1

LMI Heartbeat, 3-6, 3-62 network interface options, 3-18, 3-22–3-23 T2

options, 3-93, 4-3 troubleshooting

creating a management link, 3-78 TS Access, 2-6

LMI Inbound Heartbeat, 3-6, 3-62 T3

Management Link, 3-78, 3-80

LMI N4 Measurement Period, 3-6, 3-62 network interface options, 3-22 Tc, 3-65, 3-69 Telnet

Access Level, 3-80 TS Management SNMP Validation, 3-81 Type

user interface options, 3-89 Terminal

U

Port Use, 3-101, 3-105 Tests

UNI, 3-5–3-6, 3-61–3-62 user interface

Duration, 3-14 Timeout, 3-14 Threshold

options, 3-101 Telnet session, 3-89

Cell Delineation Error Event, 3-71 SNR Margin, 3-26 time

setting, 2-12 time slot assignments

specifying port type, 2-10, 3-31, 3-36, 3-39 V.54 Loopback, 3-20, 3-24 Value Out of Range message, 3-64–3-65, 3-68–3-69 VPI,VCI number, 3-68

synchronous data port to network or DSX-1, 3-58 time slots, 3-50 Timeout

Inactivity, 3-91, 3-103, 3-106 timers

IN-8 December 2002 9000-A2-GB31-00

Show 7 more labels / short text on this page
Index · timing · Enquiry · Access, 3-93 · Session · communication port · setting backup, 4-10
Page 165 of the Paradyne 9623 user manual — W
Page 165 · click to enlarge
Page 165

W

General Traps, 3-94 warranty, A website

access to documentation, vi glossary, v

specifying port type, 2-10, 3-31, 3-36

9000-A2-GB31-00 December 2002 IN-9

Index · warmStart · events

Page 166 of the Paradyne 9623 user manual — W
Page 166 · click to enlarge
Page 166

IN-10 December 2002 9000-A2-GB31-00

Index

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
D4Uses D4 framing format. p.23
NI-2The DBM will communicate with a service provider supporting the National ISDN-2 p.77

Ask about the Paradyne 9623

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Paradyne 9623

Be the first to ask — other owners or our team will answer.

Original document

Paradyne 9623 manual PDF

166 pages·1.5 MB·Network Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…