Paradyne 8784

110 pages·952 KB·Network Card·PDF·ENDEFRITNLJA
Paradyne 8784
Table of Contents 107 sections Contents · About This Guide · Document Purpose and Intended Audience · Document Summary · … ShowHide
Contentsp.5About This Guidep.9Document Purpose and Intended Audiencep.9Document Summaryp.9Product-Related Documentsp.10About the Hotwire 8784 TerminationUnitp.11TDM SDSL Overviewp.11Hotwire 8784 Termination Unit Featuresp.12Network Configurationp.13SNMP Management Capabilitiesp.14Management Information Base (MIB) Supportp.14SNMP Trap Supportp.14Using the Asynchronous TerminalInterfacep.15User Interface Accessp.15Management Serial Port Settingsp.15Logging In to the Hotwire DSLAMp.16Initiating an ATI Sessionp.16Menu Hierarchyp.18Screen Work Areasp.19Navigating the Screensp.20Keyboard Keysp.20Function Keysp.21Switching Between Screen Work Areasp.22Ending an ATI Sessionp.23Exiting From the DSLAM Sessionp.23Initial Startup and Configurationp.25Overviewp.25Entering Identity Informationp.26Configuring the Unitp.27Current and Default Factory Configurationsp.28Configuration Loaderp.29Saving Configuration Changesp.31Downloading Firmwarep.32AutoRate Featurep.34Disabling AutoRatep.34Resetting AutoRatep.35Restoring Access to the User Interfacep.35Resetting the Unitp.36Monitoring the Unitp.37What to Monitorp.37Viewing System and Test Statusp.38Health and Status Messagesp.39Self-Test Results Messagesp.41Test Status Messagesp.41Performance Statisticsp.42Viewing Network Error Statisticsp.42Viewing Network Performance Statisticsp.44Viewing Current Network Performancep.46Viewing DSX-1 Performance Statisticsp.47Viewing LED Statusp.49Front Panel LEDsp.50Testingp.51Accessing the Test Menup.51Running Network Testsp.52Line Loopbackp.53Repeater Loopbackp.54DTE Loopbackp.55Remote Send Line Loopbackp.56Send and Monitor 511p.57Device Testsp.58Lamp Testp.58Ending an Active Testp.59Telco-Initiated Testsp.60Telco-Initiated Line Loopbackp.60Telco-Initiated Payload Loopbackp.60Telco-Initiated Remote Line Loopbackp.61Messages and Troubleshootingp.63Overviewp.63Configuring SNMP Trapsp.64Device Messagesp.65Troubleshootingp.67Securityp.69Overviewp.69ATI Access Levelsp.69Creating a Loginp.70Deleting a Loginp.71Controlling SNMP Accessp.72Assigning SNMP Community Names and Access Typesp.72Limiting SNMP Access through the IP Addresses of the Managersp.72IP Addressingp.73Selecting an IP Addressing Schemep.73Configurations Not Running IP Conservative Softwarep.73All Configurationsp.73IP Addressing Examplep.74Configuration Optionsp.75Overviewp.75Network Interface Optionsp.76DSX-1 Interface Optionsp.78Copy Ports Optionsp.81System Optionsp.82Management and Communication Menup.84Telnet Session Optionsp.84General SNMP Management Optionsp.86SNMP NMS Security Optionsp.88SNMP Trap Optionsp.90Standards Compliance for SNMP Trapsp.93SNMP Trapsp.93warmStartp.93authenticationFailurep.93linkUp and linkDownp.94Enterprise-Specific Trapsp.95Connector Pin Assignmentsp.97Overviewp.97Front Panel 50-pin DTE Connector Pinoutsp.97Technical Specificationsp.99Glossaryp.101Indexp.105
Page 1 of the Paradyne 8784 user manual — Document No. 8784-A2-GB20-30
Page 1 · click to enlarge
Page 1

Hotwire ®

8784 TDM SDSL Termination Unit

with DSX-1 Interface

User’s Guide

Document No. 8784-A2-GB20-30

February 2001

Page 2 of the Paradyne 8784 user manual — Trademarks
Page 2 · click to enlarge
Page 2

Copyright © 2001 Paradyne Corporation. All rights reserved. Printed in U.S.A.

Notice

This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773.

Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.

Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual.

Warranty, Sales, Service, and Training Information

Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:

„ Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.)

„ Telephone: Call our automated system to receive current information by fax or to speak with a company representative.

— Within the U.S.A., call 1-800-870-2221

— Outside the U.S.A., call 1-727-530-2340

Document Feedback

We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification.

Trademarks

ACCULINK, COMSPHERE, FrameSaver, Hotwire, MVL, NextEDGE, OpenLane, and Performance Wizard are registered trademarks of Paradyne Corporation. ReachDSL and TruePut are trademarks of Paradyne Corporation. All other products and services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners.

A February 2001 8784-A2-GB20-30

Page 3 of the Paradyne 8784 user manual — !
Page 3 · click to enlarge
Page 3

!

Important Safety Instructions

1. Read and follow all warning notices and instructions marked on the product or included in the manual.
2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
3. Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord.
4. Do not attempt to install or service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or other risks. Refer all installation and servicing to qualified service personnel.
5. General purpose cables are provided with this product. Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer.
6. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.
7. A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate buildings are interconnected , the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products.
8. In addition, if the equipment is to be used with telecommunications circuits, take the following precautions:

— Never install telephone wiring during a lightning storm.

— Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

— Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

— Use caution when installing or modifying telephone lines.

— Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.

— Do not use the telephone to report a gas leak in the vicinity of the leak.

8784-A2-GB20-30 February 2001 B

Page 4 of the Paradyne 8784 user manual — !
Page 4 · click to enlarge
Page 4

EMI Notices

!

UNITED STATES – EMI NOTICE:

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation.

!

CANADA – EMI NOTICE:

This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.

Cet appareil numérique de la classe A respecte toutes les exigences du règlement sur le matérial brouilleur du Canada.

C February 2001 8784-A2-GB20-30

Page 5 of the Paradyne 8784 user manual — Table of Contents
Page 5 · Contents
Contents

Contents

Contentsp.5About This Guidep.9Document Purpose and Intended Audiencep.9Document Summaryp.9Product-Related Documentsp.10About the Hotwire 8784 TerminationUnitp.11TDM SDSL Overviewp.11Hotwire 8784 Termination Unit Featuresp.12Network Configurationp.13SNMP Management Capabilitiesp.14Management Information Base (MIB) Supportp.14SNMP Trap Supportp.14Using the Asynchronous TerminalInterfacep.15User Interface Accessp.15Management Serial Port Settingsp.15Logging In to the Hotwire DSLAMp.16Initiating an ATI Sessionp.16Menu Hierarchyp.18Screen Work Areasp.19Navigating the Screensp.20Keyboard Keysp.20Function Keysp.21Switching Between Screen Work Areasp.22Ending an ATI Sessionp.23Exiting From the DSLAM Sessionp.23Initial Startup and Configurationp.25Overviewp.25Entering Identity Informationp.26Configuring the Unitp.27Current and Default Factory Configurationsp.28Configuration Loaderp.29Saving Configuration Changesp.31Downloading Firmwarep.32AutoRate Featurep.34Disabling AutoRatep.34Resetting AutoRatep.35Restoring Access to the User Interfacep.35Resetting the Unitp.36Monitoring the Unitp.37What to Monitorp.37Viewing System and Test Statusp.38Health and Status Messagesp.39Self-Test Results Messagesp.41Test Status Messagesp.41Performance Statisticsp.42Viewing Network Error Statisticsp.42Viewing Network Performance Statisticsp.44Viewing Current Network Performancep.46Viewing DSX-1 Performance Statisticsp.47Viewing LED Statusp.49Front Panel LEDsp.50Testingp.51Accessing the Test Menup.51Running Network Testsp.52Line Loopbackp.53Repeater Loopbackp.54DTE Loopbackp.55Remote Send Line Loopbackp.56Send and Monitor 511p.57Device Testsp.58Lamp Testp.58Ending an Active Testp.59Telco-Initiated Testsp.60Telco-Initiated Line Loopbackp.60Telco-Initiated Payload Loopbackp.60Telco-Initiated Remote Line Loopbackp.61Messages and Troubleshootingp.63Overviewp.63Configuring SNMP Trapsp.64Device Messagesp.65Troubleshootingp.67Securityp.69Overviewp.69ATI Access Levelsp.69Creating a Loginp.70Deleting a Loginp.71Controlling SNMP Accessp.72Assigning SNMP Community Names and Access Typesp.72Limiting SNMP Access through the IP Addresses of the Managersp.72IP Addressingp.73Selecting an IP Addressing Schemep.73Configurations Not Running IP Conservative Softwarep.73All Configurationsp.73IP Addressing Examplep.74Configuration Optionsp.75Overviewp.75Network Interface Optionsp.76DSX-1 Interface Optionsp.78Copy Ports Optionsp.81System Optionsp.82Management and Communication Menup.84Telnet Session Optionsp.84General SNMP Management Optionsp.86SNMP NMS Security Optionsp.88SNMP Trap Optionsp.90Standards Compliance for SNMP Trapsp.93SNMP Trapsp.93warmStartp.93authenticationFailurep.93linkUp and linkDownp.94Enterprise-Specific Trapsp.95Connector Pin Assignmentsp.97Overviewp.97Front Panel 50-pin DTE Connector Pinoutsp.97Technical Specificationsp.99Glossaryp.101Indexp.105
Page 9 of the Paradyne 8784 user manual — Document Summary
Page 9 · click to enlarge
Page 9

About This Guide

Document Purpose and Intended Audience

This guide contains information needed to set up, configure, and operate the 2-port Hotwire 8784 Time Division Multiplexer Symmetric Digital Subscriber Line (TDM SDSL) Termination Unit, and is intended for installers and operators.

Document Summary

SectionDescription Chapter 1, About the Hotwire 8784 Termination UnitDescribes the Hotwire 8784 Termination Unit’s features and capabilities. Chapter 2, Using the Asynchronous Terminal InterfaceProvides instructions for accessing the user interface and navigating the screens. Chapter 3, Initial Startup and ConfigurationProvides procedures for configuring the unit. Chapter 4, Monitoring the UnitDescribes using the LEDs, status, and network statistics to monitor the unit. Chapter 5, TestingProvides information about available tests and test setup. Chapter 6, Messages and TroubleshootingProvides information on SNMP traps, device messages, and troubleshooting. Chapter 7, SecurityPresents procedures for creating a login, setting the effective access levels, and controlling SNMP access. Chapter 8, IP AddressingProvides information and examples regarding IP addresses. Appendix A, Configuration OptionsContains all configuration options, default settings, and possible settings. Appendix B, Standards Compliance for SNMP TrapsContains SNMP trap compliance information. Appendix C, Connector Pin AssignmentsLists the pin assignments for the front panel DTE connector.

8784-A2-GB20-30 February 2001 v

Page 10 of the Paradyne 8784 user manual — Document Number Document Title
Page 10 · click to enlarge
Page 10
SectionDescription Appendix D, Technical SpecificationsContains physical and regulatory specifications, network and port interfaces, power consumption values, and accessory part numbers. GlossaryDefines acronyms and terms used in this document. IndexLists key terms, acronyms, concepts, and sections in alphabetical order.

Product-Related Documents

Document Number Document Title

7970-A2-GB20 Hotwire TDM SDSL Standalone Termination Units, Models 7974, 7975, 7976, 7984, 7985, and 7986, User’s Guide

8000-A2-GB22 Hotwire Management Communications Controller (MCC) Card, IP Conservative, User’s Guide

8000-A2-GB29 Hotwire Management Communications Controller (MCC) Card User’s Guide

8600-A2-GN20 Hotwire 8600 Digital Subscriber Line Access Multiplexer (DSLAM) Installation Guide

8610-A2-GN10 Hotwire 8610 DSLAM Installation Instructions

8620-A2-GN20 Hotwire 8620 GranDSLAM Installation Guide

8784-A2-GZ40 Hotwire 8784 TDM SDSL Termination Unit, with DSX-1 Interface, Installation Instructions

8800-A2-GN21 Hotwire 8800 Digital Subscriber Line Access Multiplexer (DSLAM) Installation Guide

8810-A2-GN11 Hotwire 8810 DSLAM Installation Instructions

8820-A2-GN20 Hotwire 8820 GranDSLAM Installation Guide

Contact your sales or service representative to order additional product documentation.

Paradyne documents are also available on the World Wide Web at www.paradyne.com. Select Library → Technical Manuals.

vi February 2001 8784-A2-GB20-30

About This Guide

Page 11 of the Paradyne 8784 user manual — About the Hotwire 8784 Termination Unit
Page 11 · click to enlarge
Page 11

About the Hotwire 8784 Termination Unit

TDM SDSL Overview

Hotwire Time Division Multiplexer Symmetric Digital Subscriber Line (TDM SDSL) products maximize customer service areas by varying the DSL line rate. This ensures symmetric DSL connectivity over a wide range of telephone line distances and transmission line qualities.

TDM SDSL termination units can transport data at full (1.544 Mbps) or fractional payload rates over a 4-wire, full-duplex circuit over varying distances based on the conditions of the 4-wire loop. Examples include support for router, multiplexer and PBX connections on 24 gauge (.5 mm) cable up to 21,000 feet (6.4 km).

The termination unit is equipped with an automatic configuration capability that reduces the installation process to a simple plug-and-play procedure. Simply connect the unit to the line and it automatically configures itself for the maximum data rate supported by the local loop. The unit can also be configured for fixed line speeds to achieve maximum distances.

8784-A2-GB20-30 February 2001 1-1

Page 12 of the Paradyne 8784 user manual — Hotwire 8784 Termination Unit Features
Page 12 · click to enlarge
Page 12
1. About the Hotwire 8784 Termination Unit

Hotwire 8784 Termination Unit Features

The 2-port Hotwire 8784 TDM SDSL Termination Unit is a circuit board mounted in a Hotwire 8600 or 8800 Series Digital Subscriber Line Access Multiplexer (DSLAM) and used to transport signals at high speeds over a twisted-pair connection.

The Hotwire 8784 TDM SDSL Termination Unit offers these standard features:

„ AutoRate Capability. Provides automatic configuration of line speed and data rate upon connection.

„ Embedded Operations Channel (EOC). Provides remote management via SNMP or Telnet session capability over the SDSL network.

„ Asynchronous Terminal Interface (ATI). Provides a menu-driven VT100-compatible terminal interface for configuring and managing the unit locally or remotely by Telnet session.

„ Local Management. Provides local management using the Management Communications Card (MCC) with a:

— Terminal or PC via the Management Serial port of the DSLAM.

— Network Management System (NMS) via the Management MCC port of the DSLAM.

— NMS connection through the 10BaseT port.

„ Remote Management. Provides remote management:

— Out-of-band, using an external modem through the Management Serial port of the DSLAM.

— Telnet over the EOC.

— Using SNMP or Telnet through the 10BaseT port or the Internal Management Channel (IMC).

„ Alarm Indication. Activates front panel LEDs.

„ Diagnostics. Provides the capability to diagnose device and network problems and perform tests, including digital loopbacks, pattern tests, and self-test.

„ Device and Test Monitoring. Provides the capability of tracking and evaluating the unit’s operation, including health and status, and error-rate monitoring.

1-2 February 2001 8784-A2-GB20-30

Page 13 of the Paradyne 8784 user manual — Figure 1-2. Sample Campus Configuration
Page 13 · click to enlarge
Page 13
1. About the Hotwire 8784 Termination Unit

Network Configuration

Figure 1-1, Sample CO-to-CP Configuration, shows a T1 network application using a Hotwire 8784 TDM SDSL Termination Unit for access concentration in a central office (CO). A frame relay switch and a router are connected to partner units through the termination unit, supporting a T1 host or router and frame relay encapsulated or unframed data.

Paradyne 8784 — Network Configuration diagram (page 13)
Fig. 1 · Network Configuration

Figure 1-1. Sample CO-to-CP Configuration

Figure 1-2, Sample Campus Configuration, shows termination units used to distribute T1 lines over a campus.

Paradyne 8784 — Figure 1-1. Sample CO-to-CP Configuration diagram (page 13)
Fig. 2 · Figure 1-1. Sample CO-to-CP Configuration

Figure 1-2. Sample Campus Configuration

8784-A2-GB20-30 February 2001 1-3

Page 14 of the Paradyne 8784 user manual — SNMP Trap Support
Page 14 · click to enlarge
Page 14
1. About the Hotwire 8784 Termination Unit

SNMP Management Capabilities

The Hotwire 8784 Termination Unit supports SNMP Version 1, and can be managed by any industry-standard SNMP manager and accessed using SNMP by external SNMP managers.

Management Information Base (MIB) Support

For a detailed description of supported MIBs, visit Paradyne’s Web site at www.paradyne.com. The following MIBs are supported:

„ MIB II (RFC 1213 and RFC 1573) – Defines the general objects for use with a network management protocol in TCP/IP internets and provides general information about the unit. MIB II is backward-compatible with MIB I.

„ DS1/E1 MIB (RFC 1406) – Reports the performance status of the DSX-1 interface and supports the features found on the DSX-1 Performance Statistics screen.

„ Paradyne Enterprise MIB – Supports configuration, status, statistics, and tests.

Select Clear to reset a field to a null value.

SNMP Trap Support

The Hotwire 8784 Termination Unit supports traps as defined in RFC 1215.

Paradyne 8784 — SNMP Trap Support diagram (page 14)
Fig. 3 · SNMP Trap Support

1-4 February 2001 8784-A2-GB20-30

Page 15 of the Paradyne 8784 user manual — Management Serial Port Settings
Page 15 · click to enlarge
Page 15

Using the Asynchronous Terminal Interface

User Interface Access

You can communicate with the asynchronous terminal interface (ATI) using one of the following methods:

„ Direct connection through the Management Serial port of the DSLAM (locally or via an external modem).

„ Telnet session using a Network Management System (NMS) connected to a LAN/WAN port on the DSLAM.

„ Telnet session through the Embedded Operations Channel (EOC).

NOTE:

Only one ATI session can be active at a time, and another user’s session cannot be forced to end. To automatically log out a user due to inactivity, enable the Inactivity Timeout option (see Table A-5, Telnet Session Options, in Appendix A, Configuration Options.

Security can limit ATI access several ways. To set up security or a login ID, refer to Chapter 7, Security.

Management Serial Port Settings

Ensure that the device you connect communicates using these settings:

„ Data rate set to 9.6 kbps.

„ Character length set to 8.

„ Parity set to None.

„ Stop Bits set to 1.

Refer to the installation document for your DSLAM.

8784-A2-GB20-30 February 2001 2-1

Page 16 of the Paradyne 8784 user manual — LOGIN
Page 16 · click to enlarge
Page 16
2. Using the Asynchronous Terminal Interface

Logging In to the Hotwire DSLAM

You can log in to the Hotwire DSLAM system using either a local VT100-compatible terminal or a remote Telnet connection.

After you enter your user ID and password, the system displays the Hotwire Chassis Main Menu. See your Management Communications Controller (MCC) documentation for information about selecting the unit from the MCC card selection screen.

Initiating an ATI Session

The Main Menu screen is displayed unless a login ID and password is required or the ATI is already in use.

If the ATI is already in use, the message connection refused is sent to the terminal attempting Telnet access.

If security is enabled and Telnet is used to access the terminal unit directly (you did not log in through the MCC), the system prompts you for a login ID and password.

Login Hotwire Slot4 Model: 8784

LOGIN

Login IDEnter Password:

Ctrl-a to access these functions Exit

If you enter an invalid login ID and password three times, the Telnet session closes or the terminal connection returns to an idle state. Refer to Chapter 7, Security.

2-2 February 2001 8784-A2-GB20-30

Page 17 of the Paradyne 8784 user manual — MAIN MENU
Page 17 · click to enlarge
Page 17
2. Using the Asynchronous Terminal Interface

After you enter a valid login ID and password, the Main Menu appears.

main Access LevelAdministrator Hotwire Slot: 4 Model 8784

MAIN MENU

Status Test Configuration Control

Ctrl-a to access these functions Exit

Function Keys and Message Area

The four branches of the Main Menu are as follows:

Select . . . To . . .

Status View system status, diagnostic test results, statistics, LED status, and device identity information.

Test Select, start, stop and cancel tests for the unit’s interfaces.

Configuration Display and edit the configuration options.

Control Change the device identity, administer logins, download new firmware, or initiate a power-up reset of the unit.

What appears on the screens depends on the:

„ Current configuration – How your unit is currently configured.

„ Effective security access level – An access level that is typically set by the system administrator for each interface and each user.

„ Data selection criteria – What you entered in previous screens.

8784-A2-GB20-30 February 2001 2-3

Screen Area

Page 18 of the Paradyne 8784 user manual — SNMP NMS
Page 18 · click to enlarge
Page 18
2. Using the Asynchronous Terminal Interface

Menu Hierarchy

The following illustration shows the paths to the different ATI screens.

Network & DSX-1 Tests

Network DSX-1 Copy Ports

SNMP NMS

SNMP

2-4 February 2001 8784-A2-GB20-30

Show 43 more labels / short text on this page
Main · Status Test · Configuration Control · System and · Performance · Display · Identity · Change · Download · Reset Autorate · Test Status · Statistics · LEDs · Identity · Code · Administer · Apply Download · Reset · Logins · Card · Network · Network Performance · DSX-1 Statistics · Current Network Performance · Error Statistics · Statistics · Statistics · Default Factory Configuration · Configuration · Current Configuration · Loader · Device · Abort All · Tests · Tests · System Options · Management · and Communication · Telnet Session · Security General SNMP · Management · Traps · 01-15708-03
Page 19 of the Paradyne 8784 user manual — NETWORK INTERFACE OPTIONS
Page 19 · click to enlarge
Page 19
2. Using the Asynchronous Terminal Interface

Screen Work Areas

There are two user work areas:

„ Screen area – This is the area above the dotted line that provides the menu path, menus, and input fields.

The menu path appears as the first line on the screen. In this manual, the menu path is presented as a menu selection sequence:

Main Menu→Configuration →Current Configuration→Network

„ Function key and message area – This is the area below the dotted line that lists function keys specific to the screen, field value choices, and system messages.

main/config/network Hotwire Slot4 Model: 8784 Port: 2

NETWORK INTERFACE OPTIONS

Margin Threshold–3db Excessive Error Rate Threshold: 1E–5 AutoRate Disable DSL Line rate 1552
Circuit IdentifierClear

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save Select: 1E–4, 1E–5, 1E–6, 1E–7, 1E–8, 1E–9 LOS at Net, Pt n

8784-A2-GB20-30 February 2001 2-5

Show 5 more labels / short text on this page
Menu Path · Input Fields · Function Keys · Field Value Choices · System Messages
Page 20 of the Paradyne 8784 user manual — Procedure
Page 20 · click to enlarge
Page 20
2. Using the Asynchronous Terminal Interface

Navigating the Screens

You can navigate the screens by:

„ Using keyboard keys

„ Using function keys

„ Switching between the two screen areas

Keyboard Keys

Use the following keyboard keys to navigate within the screen.

Press . . . To . . .

Ctrl-a Move cursor between the screen area and the function key and message area below the dotted line at the bottom of the screen.

Esc Return to the previous screen.

Tab Move cursor to the next field on the screen.

Backspace Move cursor to the previous field on the screen.

Enter Accept entry or display valid options on the last row of the screen when pressed before entering data or after entering invalid data.

Ctrl-k Tab backwards (move cursor one field to the left).

Spacebar Select the next valid value for the field.

Delete (Del) Delete character that the cursor is on.

Up Arrow or Ctrl-u Move cursor up one field within a column on the same screen.

Down Arrow or Ctrl-d Move cursor down one field within a column on the same screen.

Right Arrow or Ctrl-f Move cursor one character to the right if in edit mode.

Left Arrow or Ctrl-b Move cursor one character to the left if in edit mode.

Ctrl-l Redraw the screen display, clearing information typed in but not yet entered.

Procedure

To make a menu or field selection:

1. Press the Tab or right arrow key to position the cursor on a menu or field selection. Each selection is highlighted as you press the key to move the cursor from position to position.
2. Press Enter. The selected menu or screen appears.
3. Continue Steps 1 and 2 until you reach the screen you want.

2-6 February 2001 8784-A2-GB20-30

Page 21 of the Paradyne 8784 user manual — Function Keys
Page 21 · click to enlarge
Page 21
2. Using the Asynchronous Terminal Interface

The current setting or value appears to the right of the field name. You can enter information into a selected field by:

„ Typing in the first letter(s) of a field value or command.

„ Switching from the screen area to the function key and message area below the dotted line, and selecting a function key.

If a field is blank and the Field Value Choices display valid selections, press the spacebar; the first valid value for the field will appear in the field. Continue pressing the spacebar to scroll through other valid values. Press Enter to select the value.

If a field is blank and the Field Values screen area displays valid selections, press the spacebar and the first valid value for the field will appear. Continue pressing the spacebar to scroll through other valid values.

Function Keys

All screen function keys located below the dotted line operate the same way (upper- or lowercase) throughout the screens.

For the screen function . . . Select . . . And press Enter to . . .

ClrFar F or f Clear far-end network statistics and refresh the screen.

ClrNear N or n Clear near-end network statistics and refresh the screen.

ClrStats S or s Clear DSX-1 statistics and refresh the screen.

Delete L or l Delete data.

Exit E or e Terminate the asynchronous terminal session.

MainMenu M or m Return to the Main Menu screen.

New N or n Enter new data.

PgDn D or d Display the next page, or group of entries.

PgUp U or u Display the previous page, or group of entries.

ResetMon R or r Reset an active Monitor 511 test counter to zero.

Save S or s Save information.

8784-A2-GB20-30 February 2001 2-7

Page 22 of the Paradyne 8784 user manual — NETWORK INTERFACE OPTIONS
Page 22 · click to enlarge
Page 22
2. Using the Asynchronous Terminal Interface

Switching Between Screen Work Areas

Select Ctrl-a to switch between the two screen areas.

Procedure

To access the screen function area below the dotted line:

1. Press Ctrl-a to switch from the screen area to the function keys.
2. Enter the designated (underlined) character for the function key or press the Tab key until you reach the desired function key.

Example: To save the current options, type s or S (Save).

3. Press Enter. The function is performed.
4. To return to the screen area above the dotted line, press Ctrl-a again.
main/config/network Hotwire Slot4 Model: 8784 Port: 2

NETWORK INTERFACE OPTIONS

Margin Threshold–3db Excessive Error Rate Threshold: 1E–5 AutoRate: Disable DSL Line Rate: 1552
Circuit IdentifierClear

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

2-8 February 2001 8784-A2-GB20-30

Page 23 of the Paradyne 8784 user manual — Procedure
Page 23 · click to enlarge
Page 23
2. Using the Asynchronous Terminal Interface

Ending an ATI Session

Use the Exit function key from any screen to terminate the session.

Procedure

To end a session with the asynchronous terminal interface:

1. Press Ctrl-a to go to the function keys.
2. Save changes if required. A confirmation message appears if you have made but not saved changes to your configuration.
3. Tab to Exit (or type e or E ) and press Enter. If you have accessed the card through the MCC, the Hotwire Chassis Card Selection menu appears.

Exiting From the DSLAM Session

You can manually log out of the system or, after five minutes of inactivity, the system automatically logs out when the inactivity time-out option is enabled.

Procedure

To manually exit from the Hotwire DSLAM system:

1. Return to the Hotwire Chassis Main Menu by selecting Exit from either the Hotwire – MCC menu or the Hotwire – DSL menu.

The Hotwire Card Selection menu appears.

2. Press Ctrl-z.

The Hotwire Chassis Main Menu appears.

3. From the Hotwire Chassis Main Menu, select Logout.

The system exits from the current login session on the Hotwire DSLAM.

8784-A2-GB20-30 February 2001 2-9

Page 24 of the Paradyne 8784 user manual — Ending an ATI Session
Page 24 · click to enlarge
Page 24
2. Using the Asynchronous Terminal Interface

2-10 February 2001 8784-A2-GB20-30

Page 25 of the Paradyne 8784 user manual — Initial Startup and Configuration
Page 25 · click to enlarge
Page 25

Initial Startup and Configuration

Overview

This chapter provides instructions on how to access the unit for the first time, configure it, download firmware, disable or reset the AutoRate feature, restore access to the ATI, and reset the unit. These procedures include:

„ Entering Identity Information on page 3-2

„ Configuring the Unit on page 3-3

— Current and Default Factory Configurations on page 3-4

— Configuration Loader on page 3-5

„ Saving Configuration Changes on page 3-7

„ Downloading Firmware on page 3-8

„ AutoRate Feature on page 3-10

— Disabling AutoRate on page 3-10

— Resetting AutoRate on page 3-11

„ Restoring Access to the User Interface on page 3-11

„ Resetting the Unit on page 3-12

8784-A2-GB20-30 February 2001 3-1

Page 26 of the Paradyne 8784 user manual — IDENTITY
Page 26 · click to enlarge
Page 26
3. Initial Startup and Configuration

Entering Identity Information

After accessing the unit for the first time, use the Change Identity screen to determine SNMP administrative system information that will be displayed on the Identity screen.

To access the Identity screen, follow this menu selection sequence:

Main Menu→Control→Change Identity

main/control/change_identity Hotwire Slot: 4 Model: 8784

IDENTITY

System Name: lllQJ98-001 Clear System Location: Bldg. A412, 2nd Floor, Left cabinet Clear System Contact: C. Parker 800-727-2396 pager 888-555-1212 Clear

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

The three System entry fields are alphanumeric and provide up to 128 characters per field. The SNMP System entry fields are:

„ System Name: The general SNMP system name.

„ System Location: The physical location of the SNMP-managed device.

„ System Contact: Identification information, such as contact name, phone number, or mailing address.

Valid entry values are any printable ASCII character. ASCII printable characters include:

„ Upper- or lowercase A–Z

„ All ASCII symbols except the caret (^)

Select Clear to reset a field to a null value.

3-2 February 2001 8784-A2-GB20-30

„ Numeric 0–9 · „ Space

Page 27 of the Paradyne 8784 user manual — LOAD CONFIGURATION FROM:
Page 27 · click to enlarge
Page 27
3. Initial Startup and Configuration

Procedure

To change Identity information:

1. Position the cursor in the System Name field. Enter a name unique in your network to identify the SNMP managed node (or unit).
2. Position the cursor in the System Location field. Enter the physical location of the unit.
3. Position the cursor in the System Contact field. Enter the name and contact information for the person responsible for the unit.
4. Press Ctrl-a to switch to the function key and message key area below the dotted line.
5. Select Save and press Enter.

Configuring the Unit

Configuration option settings determine how the termination unit operates. Use the Configuration menus to select, display, or change configuration option settings.

The unit is shipped with factory settings that match the options and settings in the Default Factory Configuration area.

To display configuration options, follow this menu selection sequence:

Main Menu→Configuration (Load Configuration From)

main/configuration Hotwire Slot4 Model: 8784

LOAD CONFIGURATION FROM:

Current Configuration Configuration Loader Default Factory Configuration

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

8784-A2-GB20-30 February 2001 3-3

Page 28 of the Paradyne 8784 user manual — CONFIGURATION EDIT/DISPLAY
Page 28 · click to enlarge
Page 28
3. Initial Startup and Configuration

Make a selection by placing the cursor at your choice and pressing Enter.

If you select . . . Then . . .

The selected configuration option set is loaded and the Configuration Edit/Display menu appears. This is the unit’s currently active configuration.

The Configuration Loader screen is displayed allowing you to upload or download configurations from a TFTP server.

The factory-set configuration options are loaded and the Configuration Edit/Display menu appears. This is a read-only configuration area.

Current and Default Factory Configurations

The Configuration Edit/Display screen appears when the current or default configuration is loaded. To access the Configuration Edit/Display screen, follow this menu selection sequence:

Main Menu→Configuration →Current Configuration

Main Menu→Configuration →Default Factory Configuration

main/config/edit Hotwire Slot4 Model: 8784

CONFIGURATION EDIT/DISPLAY

Network DSX-1 Copy Ports System Options Management and Communication

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

Load Default Factory Configuration to reset the unit’s configuration to its original factory-set configuration to restore access to the ATI when the unit has been misconfigured.

In the menu selection sequences contained in this manual, Current Configuration is assumed and shown.

3-4 February 2001 8784-A2-GB20-30

Show 4 more labels / short text on this page
Current Configuration · Configuration Loader · Default Factory Configuration · – or –
Page 29 of the Paradyne 8784 user manual — CONFIGURATION LOADER
Page 29 · click to enlarge
Page 29
3. Initial Startup and Configuration

See Appendix A, Configuration Options, for a list and explanation of the configuration options available.

Select . . . To Access the . . . To Configure the . . .

Network Network Interface Options (Table A-1) DSL network interface Ports 1–2.

DSX-1 DSX-1 Interface Options (Table A-2) DSX-1 interface Ports 1–2.

Copy Ports Copy Ports Options (Table A-3) DSL network and DSX-1 interface ports by copying options from port to port.

System Options System Options (Table A-4) General system options of the unit.

„ Telnet Session Options (Table A-5)

Management support of the unit through SNMP and Telnet.

„ General SNMP Management Options

(Table A-6)

„ SNMP NMS Security Options

(Table A-7)

„ SNMP Trap Options (Table A-8)

Configuration Loader

The Configuration Loader screen allows you to upload configurations to and download configurations from a TFTP server. To access the Configuration Loader screen, follow this menu selection sequence:

Main Menu→Configuration →Configuration Loader

main/config/config_loader Hotwire Slot4 Model: 8784

CONFIGURATION LOADER

Image File Name: Clear TFTP Server IP Address: 000.000.000.000 Clear TFTP Transfer Direction: Download from Server Destination: DSL1

Start TransferYes
Packets Sent0000000 Packets Received: 0000000 Bytes Sent: 0000000 Bytes Received: 0000000 Transfer Status: Transfer Pending

Activate new configuration? No

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

8784-A2-GB20-30 February 2001 3-5

Management and Communication

Page 30 of the Paradyne 8784 user manual — NOTE:
Page 30 · click to enlarge
Page 30
3. Initial Startup and Configuration

Procedure

To upload or download a configuration:

1. Position the cursor in the Image File Name field. Type the name of the file to be downloaded, or the name to be used for the file to be uploaded.

The file name may be a regular path name expression of directory names separated by a forward slash (/) ending with the file name. The total path name length can be up to 128 characters.

— DOS machine: If the TFTP server is hosted by a DOS machine, then directory and filenames must consist of eight or less characters with an optional suffix of up to three characters. The system will automatically upload the configuration file and create directories and filenames as needed.

— UNIX machine: If your server is hosted by a UNIX machine, the configuration file you name must already exist. It will not be created on the UNIX system by the TFTP server. It is critical that you work with your system administrator to plan the naming conventions for directories, filenames, and permissions so that anyone using the system has read and write permissions.

2. Position the cursor in the TFTP Server IP Address field. Enter the TFTP server IP address.

The first three digits of the IP address cannot be 000 or greater than 223.

3. Position the cursor in the TFTP Transfer Direction field. Use the spacebar to select Download from Server or Upload to Server.
4. Position the cursor in the Destination field. Use the spacebar to select a network destination for the TFTP server. Select DSL if the TFTP server destination is the DSL link port or IMC (in-band management channel) if the TFTP destination is the Management port of the MCC.
5. Position the cursor at the Start Transfer field. Use the spacebar to select Yes. Press Enter.

When the data transfer is complete, the Transfer Status field changes to Completed successfully.

6. Position the cursor at the Activate new configuration? prompt and select Yes to activate a new downloaded configuration. Press Enter.

NOTE:

The following option settings are not changed:

— DSL Mode and Telnet Session configuration options

— Peer IP address

You must change these settings with the appropriate configuration menus after the new configuration is activated. See Table A-1, Network Interface Options, Table A-4, System Options, and Table A-5, Telnet Session Options, in Appendix A, Configuration Options.

3-6 February 2001 8784-A2-GB20-30

Page 31 of the Paradyne 8784 user manual — NOTE:
Page 31 · click to enlarge
Page 31
3. Initial Startup and Configuration

Saving Configuration Changes

When changes are made to the configuration options through the Configuration Edit/Display menu, the changes must be saved to take effect. Use the Save function key to go to the Save Configuration screen.

main/config/saveprompt Hotwire Slot4 Model: 8784

SAVE CONFIGURATION

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Procedure

To save configuration options changes:

1. Press Ctrl-a to switch to the function keys area below the dotted line.
2. Select Save and press Enter.

If the Telnet Session configuration option is changed, a message displays on the Save Configuration screen warning that an answer of Yes will cause the Telnet session to disconnect. Do not answer Yes unless you are prepared to disconnect.

If the DSL Mode configuration option is changed, the Save Configuration screen bears the warning that an answer of Yes will cause the system to reset. Do not answer Yes unless you are prepared to reset the unit.

NOTE:

When Exit is selected before Save, or Save has been selected from any Configuration/Edit menu, a Save Configuration screen appears that requires a Yes or No response. If you select:

— Yes, the configuration is saved.

— No, the Main Menu reappears and changes are not saved.

8784-A2-GB20-30 February 2001 3-7

Save Changes? No · Command Complete

Page 32 of the Paradyne 8784 user manual — Procedure
Page 32 · click to enlarge
Page 32
3. Initial Startup and Configuration

Downloading Firmware

The Download Code screen allows you to download firmware from a TFTP server. To access the Download Code screen, follow this menu selection sequence:

Main Menu→Control →Download Code

main/control/download_code Hotwire Slot4 Model: 8784

DOWNLOAD CODE

Image File Name: Clear TFTP Server IP Address: 000.000.000.000 Clear Destination: DSL1 Immediately Apply Download: No Start Transfer: Yes

Packets Sent0000000 Packets Received: 0000000 Bytes Sent: 0000000 Bytes Received: 0000000 Transfer Status: Transfer Pending

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Procedure

To download firmware:

1. Position the cursor in the Image File Name field. Type the name of the file to be downloaded.

The file name may be a regular path name expression of directory names separated by a forward slash (/) ending with the file name. The total path name length can be up to 128 characters.

2. Position the cursor in the TFTP Server IP Address field. Enter the TFTP server IP address.

The first three digits of the IP address cannot be 000 or greater than 223.

3. Position the cursor in the Destination field. Use the spacebar to select a network destination for the TFTP server.
4. Position the cursor in the Immediately Apply Download field. If you would like the download to be effective immediately, select Yes .

3-8 February 2001 8784-A2-GB20-30

Page 33 of the Paradyne 8784 user manual — NOTE:
Page 33 · click to enlarge
Page 33
3. Initial Startup and Configuration
5. Position the cursor at the Start Transfer field. Use the spacebar to select Yes. Press Enter.

When the data transfer is complete:

— If you selected Yes in Step 4, the unit is reset.

— If you selected No, the Transfer Status field changes to Completed successfully.

If you specified No (the default) in the Immediately Apply Download field in Step 4, you must now apply the download.

main/control/apply_download Hotwire Slot4 Model: 8784

APPLY DOWNLOAD

Switch To Code Revision A01.00.02No

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

SelectYes, No LOS at Net, Pt 1

Procedure

To apply the downloaded firmware:

1. Press the Escape key to return to the Control menu. Select Apply Download.
2. On the Apply Download screen, type Yes to reset the card and activate the code.

Selecting Yes causes the termination unit to reset.

NOTE:

The termination unit has two flash memory banks to hold executable firmware. You can switch between these two firmware versions by applying the firmware listed on the Apply Download screen.

8784-A2-GB20-30 February 2001 3-9

Page 34 of the Paradyne 8784 user manual — Procedure
Page 34 · click to enlarge
Page 34
3. Initial Startup and Configuration

AutoRate Feature

The AutoRate feature is designed to find the best rate possible for your DSL loop conditions. After the DSL loop is up, configure the unit for a fixed rate. AutoRate can be enabled or disabled from the Network Interface Options screen and reset from the Control menu.

Disabling AutoRate

The AutoRate function is controlled from the Network Interface Options screen and allows you to enable or disable AutoRate. The AutoRate option is only available if the unit is configured as an LTU.

To access the Network Interface screen, follow this menu selection sequence:

Main Menu→Configuration→Current Configuration →Network

main/config/network Hotwire Slot4 Model: 8784 Port: 1

NETWORK INTERFACE OPTIONS

Margin Threshold–3db Excessive Error Rate Threshold: 1E–5 AutoRate Disable DSL Line Rate 1552
Circuit IdentifierClear

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

The AutoRate option defaults to Enable.

Procedure

To disable AutoRate:

1. Position the cursor in the AutoRate field and press the spacebar.

The AutoRate field toggles to Disable and the DSL Line Rate field appears.

2. Enter a DSL Line Rate and press Enter.

3-10 February 2001 8784-A2-GB20-30

Page 35 of the Paradyne 8784 user manual — Procedure
Page 35 · click to enlarge
Page 35
3. Initial Startup and Configuration

Resetting AutoRate

The Reset AutoRate function on the Control menu causes the unit to repeat the AutoRate sequence. The unit attempts to establish the DSL link at the highest rate (or the value of DSL Line Rate, which represents the AutoRate ceiling when AutoRate is enabled). If the link fails, the next lower rate is tried until the link is established.

To access the Reset AutoRate screen, follow this menu selection sequence:

Main Menu→Control→Reset AutoRate

Restoring Access to the User Interface

Improper configuration of the unit could render the user interface inaccessible. If this occurs, access can be restored using the MCC.

Procedure

To reset the DSL Card:

1. Select Configuration → DSL Cards → Reset Slot.
2. Enter DSL nn, where nn is the slot number for the DSL card you wish to reset.
3. Enter Reset .
4. Enter Y if you want to clear NVRAM also, otherwise enter N .

Entering Y restores the Default Factory Configuration.

5. Enter Y at the prompt to confirm.

NOTE:

When you enter Y, all data connectivity is interrupted.

You can also restore access to the user interface by reloading the Default Factory Configuration options using the unit’s menus.

Procedure

To restore access to the ATI using the unit’s menus:

Main Menu→Configuration→Default Factory Configuration

8784-A2-GB20-30 February 2001 3-11

Page 36 of the Paradyne 8784 user manual — Procedure
Page 36 · click to enlarge
Page 36
3. Initial Startup and Configuration

Resetting the Unit

If the user interface is functional and you would like to reset the unit without removing it from the DSLAM, you can reset the unit from the Control menu.

Procedure

To reset the unit from the Control menu:

1. Follow this menu selection sequence:

Main Menu→Control→Reset Device

The message Are you sure? appears.

2. Enter Yes .

3-12 February 2001 8784-A2-GB20-30

Page 37 of the Paradyne 8784 user manual — Monitoring the Unit
Page 37 · click to enlarge
Page 37

Monitoring the Unit

What to Monitor

This chapter presents information on how to access and monitor unit status and performance statistics on the network. The following sections describe how you can monitor unit operations:

„ Viewing System and Test Status on page 4-2

— Health and Status Messages on page 4-3

— Self-Test Results Messages on page 4-5

— Test Status Messages on page 4-5

„ Performance Statistics on page 4-6

— Viewing Network Error Statistics on page 4-6

— Viewing Network Performance Statistics on page 4-8

— Viewing Current Network Performance on page 4-10

— Viewing DSX-1 Performance Statistics on page 4-11

„ Viewing LED Status on page 4-13

„ Front Panel LEDs on page 4-14

8784-A2-GB20-30 February 2001 4-1

Page 38 of the Paradyne 8784 user manual — Viewing System and Test Status
Page 38 · click to enlarge
Page 38
4. Monitoring the Unit

Viewing System and Test Status

To view System and Test Status information, follow this menu selection sequence:

Main Menu→Status→System and Test Status

main/status/system Hotwire Slot4 Model: 8784

SYSTEM AND TEST STATUS Page 1 of 1

HEALTH AND STATUS SELF-TEST RESULTS TEST STATUS LOS at Net, Pt n CPU Failed No Test Active OOF at Net, Pt n Device Failed LLB Test Active, Pt n EER at Net, Pt n Net DSL Failed, Pt n RLB Test Active, Pt n LOS at DSX-1 Pt n DSX-1 Pt Failed, Pt n Lamp Test Active Net Margin Threshold, Pt n Memory Failed DLB Test Active, Pt n Device Failed yyyyyyyy Passed Download Failed

ESC for previous menu MainMenu Exit

The System and Test Status screen has three sections:

„ Health and Status – Displays messages in priority order (highest to lowest). Refer to Table 4-1, Health and Status Messages.

„ Self-Test Results – Results of the Diagnostic test run on the device itself. Refer to Table 4-2, Self-Test Results Messages.

„ Test Status – Currently active tests. Refer to Table 4-3, Test Status Messages.

4-2 February 2001 8784-A2-GB20-30

Page 39 of the Paradyne 8784 user manual — Table 4-1. Health and Status Messages (1 of 2)
Page 39 · click to enlarge
Page 39
4. Monitoring the Unit

Health and Status Messages

The following messages appear in the first column of the System and Test Status screen. The highest priority Health and Status message also appears on all ATI screens on the bottom right.

Table 4-1. Health and Status Messages (1 of 2)

Message What Message Indicates What To Do

AIS at DSX-1, Pt n

An Alarm Indication Signal (AIS) is being received by the DSX-1 interface.

1. Verify that the unit’s line framing and line coding are compatible.
2. Contact network provider.

An internal error has been detected by the operating software. yyyyyyyy indicates the 8-digit hexadecimal failure code.

1. Provide the 8-digit failure code shown (yyyyyyyy) to your service representative.
2. Reset the unit to clear the condition and message.

Download Failed A firmware download was interrupted.

Repeat the download.

EER at DSX-1, Pt n

An EER (Excessive Error Rate) condition has been detected on the DSX-1 interface.

1. Verify the attached equipment coding is compatible.
2. Contact network provider.

EER at Net, Pt n An EER (Excessive Error Rate) condition has been detected on the network interface at Port n. The condition is cleared when the error rate falls below the threshold value currently configured.

1. Check the Network Performance Statistics screen for possible line impairments.
2. Set the unit to run at a lower DSL line rate.

LOF at DSX-1, Pt n

An LOF (Loss Of Frame) condition has been detected on the DSX-1 interface.

1. Verify that the network cable is securely attached at both ends.
2. Contact network provider.

LOS at DSX-1, Pt n

An LOS (Loss Of Signal) condition has been detected on the DSX-1 interface. No signal is being received on Port n.

Verify that the interface cable is securely attached at both ends.

LOS at Net, Pt n An LOS (Loss Of Signal) condition has been detected on the network interface. No signal is being received on Port n, possibly due to a local network problem.

1. Verify that the network cable is securely attached at both ends.
2. Contact network provider.

8784-A2-GB20-30 February 2001 4-3

Device Failed yyyyyyyy

Page 40 of the Paradyne 8784 user manual — Table 4-1. Health and Status Messages (2 of 2)
Page 40 · click to enlarge
Page 40
4. Monitoring the Unit

Table 4-1. Health and Status Messages (2 of 2)

Message What Message Indicates What To Do

Net Com Link Down The Network communication link is down. Communications between the management system and the LTU/NTU is not possible.

1. Verify that the network cable is securely attached at both ends.
2. Verify the link protocol for the COM port is configured correctly.

Net Margin Threshold, Pt n

The signal-to-noise margin has exceeded the configured threshold.

1. Check the Network Performance Statistics screen for possible line impairments.
2. Set the unit to run at a lower DSL line rate.
3. Contact network provider.

NTU/LTU Mis match, Pt n

The NTU is not configured compatibly with the LTU.

Configure units to match.

OOF at Net, Pt n Three consecutive frame synchronization bits were in error.

1. Check the Transmit Clock Source configuration options. Do not set both the local and remote unit to Internal, External, or Loop timing.
2. Set the unit to run at a lower DSL line rate.
3. Contact network provider.

Prim Clk Failed Pt n A failure has occurred in the primary clock source configured from the Network, DSX, or from the card internal clock.

1. Verify that the network cable is securely attached at both ends.
2. Contact network provider.

System Operational There are no problems detected.

No action is needed.

Yellow at DSX-1, Pt n A Yellow Alarm Indication signal is being received by the DSX-1 interface.

1. Verify that the unit’s line framing and line coding are compatible.
2. Contact network provider.

4-4 February 2001 8784-A2-GB20-30

Page 41 of the Paradyne 8784 user manual — Table 4-3. Test Status Messages
Page 41 · click to enlarge
Page 41
4. Monitoring the Unit

Self-Test Results Messages

The results of the last power-on or reset self-test appear in the middle column of the System and Test Status screen.

Table 4-2. Self-Test Results Messages

Message What Message Indicates What To Do

CPU Failed The CPU failed internal testing.

1. Reset the unit and try again.
2. Call your service representative for assistance. Device Failed One or more of the unit’s integrated circuit chips has failed device-level testing.

DSX-1 Failed, Pt n The unit failed to internally loop data on the DSX-1 Port n.

Failure xxxxxxxx An internal failure occurred. (xxxxxxxx represents an 8-digit hexadecimal failure code for use by service personnel.)

Record the failure code and contact your service representative.

Memory Failed The unit failed memory verification.

1. Reset the unit and try again.
2. Call your service representative for assistance. Net DSL Failed, Pt n The unit failed to loop data on the network DSL circuit of Port n.

Passed No errors were detected. No action is needed.

Test Status Messages

The Test Status messages in the following table appear in the right column of the System and Test Status screen.

Table 4-3. Test Status Messages

Test Status Message Meaning

511 Test Active, Pt n A 511 Test and Monitor is active on the DSL Port n network interface.

DLB Test Active, Pt n A Data Terminal Loopback test is active on Port n.

Lamp Test Active The Lamp Test is active, causing the LEDs on the front panel to light.

LLB Test Active, Pt n A network Line Loopback test is active on Port n.

No Test Active No tests are currently running.

RLB Test Active, Pt n A network Repeater Loopback test is active on Port n.

For information on testing, refer to Chapter 5, Testing.

8784-A2-GB20-30 February 2001 4-5

Page 42 of the Paradyne 8784 user manual — Viewing Network Error Statistics
Page 42 · click to enlarge
Page 42
4. Monitoring the Unit

Performance Statistics

Performance statistics can assist you in determining the duration of specific conditions and provide a historical context for problem detection and analysis. Statistics are maintained for up to 96 15-minute intervals (24 hours).

Select a port to view performance statistics for that port. Port 1 is the default.

Use the applicable virtual function keys to page through the intervals and clear statistics.

„ Select PgUp or PgDn to view more statistics.

„ Select ClrNear or ClrFar to clear the near- and far-end statistics to zero.

„ Select ClrStats to clear all statistics to zero.

Viewing Network Error Statistics

The terminal unit maintains error statistics on the network DSL interface for each port.

To view Network Error Statistics, follow this menu selection sequence:

Main Menu→Status→Performance Statistics→Network Error Statistics

main/status/performance/net_error Hotwire Slot: 4: Model: 8784 Port: 2 NETWORK ERROR STATISTICS

Current Interval Timer: 2 Error Events Counter: 34 ---ES--- ---SES--- --FEBE-- -Complete- Near Far Near Far Near Far Near Far Current Int: 000 Yes No Interval 01 000 Yes Yes Interval 02 000 Yes Yes Interval 03 000 Yes Yes Interval 04 000 Yes Yes Interval 05 000 Yes Yes Interval 06 000 Yes Yes Interval 07 000 Yes Yes

Worst Interval: 24 09 14 08 18 18 Near Tot(valid): 00010 00000 00000 Far Tot(valid): 00010 00000 00000

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit PgUp PgDn ClrNear ClrFar

4-6 February 2001 8784-A2-GB20-30

Page 43 of the Paradyne 8784 user manual — Performance Statistics
Page 43 · click to enlarge
Page 43
4. Monitoring the Unit

The following Network Error Statistics are collected for the selected port:

„ ES (Errored Seconds): Seconds during which one or more ESF error events occurred.

„ SES (Severely Errored Seconds): Seconds during which more than 320 cyclic redundancy check (CRC) error events or at least one Out of Frame (OOF) event occurred.

„ FEBE (Far-End Block Errors): Errors reported by the remote equipment.

„ Complete: Whether the interval register contains data for all 900 seconds of the interval.

Fields on this screen include:

Field . . . Contains . . .

Current Interval Timer The number of seconds which have elapsed in the current 15-minute interval. Maximum value is 900 seconds (15 minutes). This counter is reset every 15 minutes. When zero, the port is disabled.

Error Events Counter A running total of CRC errors. Range 0–65535. This counter resets when the near-end data is cleared. When zero, the port is disabled.

Current Int Performance data for the current 15-minute interval. When blank, the port is disabled.

Interval xx Historical performance data for up to 96 15-minute intervals (24 hours). When blank, the port is disabled.

Worst Interval The number of the interval with the worst (highest) performance data for both the near- and far-end statistics. If two or more intervals are equal, the oldest interval is displayed. When blank, the port is disabled.

Near and Far Tot A running total of the near- and far-end performance statistics.

8784-A2-GB20-30 February 2001 4-7

Page 44 of the Paradyne 8784 user manual — Viewing Network Performance Statistics
Page 44 · click to enlarge
Page 44
4. Monitoring the Unit

Viewing Network Performance Statistics

Network performance statistics allow you to monitor the current status of the network DSL operations.

To view Network Performance Statistics for a port, follow this menu selection sequence:

Main Menu→Status→Performance Statistics→ Network Performance Statistics

main/status/performance/net_perf Hotwire Slot: 4: Model: 8784 Port: 2 NETWORK PERFORMANCE STATISTICS Payload Rate: 1536 kbps Current Interval Timer: 002 DSL Line Rate: 1552 kbps --Mrgn-- --XmtPw- --RxGn-- -Complete- Near Far Near Far Near Far Near Far Current Int: +02 +01 +03 +03 +02 +02 Yes Yes Interval 01 +02 +02 +03 +03 +02 +02 Yes No Interval 02 +02 +01 +03 +03 +02 +02 Yes Yes Interval 03 +02 +01 +03 +03 +02 +02 Yes Yes Interval 04 +02 +01 +03 +03 +02 +02 Yes Yes Interval 05 +02 +01 +03 +03 +02 +02 Yes Yes Interval 06 +02 +01 +03 +03 +02 +02 Yes Yes Interval 07 +02 +01 +03 +03 +02 +02 Yes Yes

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit PgUp PgDn ClrNear ClrFar

The following Network Performance Statistics are collected for the selected port:

„ Mrgn: Signal to Noise Ratio (SNR) Margin, the amount (in dB) that the Receive signal has exceeded the value needed to maintain a Bit Error Ratio (BER) of 10–7 or better.

„ XmtPw: The transmit power level.

„ RxGn: The receiver gain level.

„ Complete: Whether the interval register contains data for all 900 seconds of the interval.

4-8 February 2001 8784-A2-GB20-30

Page 45 of the Paradyne 8784 user manual — Viewing Network Performance Statistics
Page 45 · click to enlarge
Page 45
4. Monitoring the Unit

Fields on this screen include

This Field . . . Contains . . .

Current Interval Timer The number of seconds which have elapsed in the current 15-minute interval. Maximum value is 900 seconds (15 minutes). This counter resets every 15 minutes.

DSL Line Rate The rate of the DSL line (400 to 1552 kbps).

Payload Rate The rate of data transfer.

Current Int Performance data for the current 15-minute interval.

Interval xx Historical performance data for up to 96 15-minute intervals (24 hours).

8784-A2-GB20-30 February 2001 4-9

Page 46 of the Paradyne 8784 user manual — Viewing Current Network Performance
Page 46 · click to enlarge
Page 46
4. Monitoring the Unit

Viewing Current Network Performance

The Current Network Performance Statistics screen allows you to monitor selected current network status and error information for both the near- and far-end units from a single screen.

To view Current Network Performance for a port, follow this menu selection sequence:

Main Menu→Status→Performance Statistics→Current Network Performance

main/status/performance/current Hotwire Slot: 4: Model: 8784 Port: 2 CURRENT NETWORK PERFORMANCE STATISTICS Payload Rate: 1536 kbps Current Interval Timer: 002 DSL Line Rate: 1552 kbps

Near End Far End Margin +02 +01 XmtPw +03 +03 RxGn +02 +02

ES 002 000 SES 002 000 FEBE 000 000

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit ClrNear ClrFar Select: 1, 2, 3, 4 LOS at Net, Pt 1

The following Network Performance Statistics are collected for the selected port:

„ Mrgn: Signal to Noise Ratio (SNR) Margin, the amount (in dB) that the Receive signal has exceeded the value needed to maintain a Bit Error Rate (BER) of 10–7 or better.

„ XmtPw: The transmit power level.

„ RxGn: The receiver gain level.

The following Network Error Statistics are collected for the selected port:

„ ES (Errored Seconds): Seconds during which one or more ESF error events occurred.

„ SES (Severely Errored Seconds): Seconds during which more than 320 cyclic redundancy check (CRC) error events or at least one Out of Frame (OOF) event occurred.

„ FEBE (Far-End Block Errors): Errors reported by the remote equipment.

4-10 February 2001 8784-A2-GB20-30

Page 47 of the Paradyne 8784 user manual — Viewing DSX-1 Performance Statistics
Page 47 · click to enlarge
Page 47
4. Monitoring the Unit

Fields on this screen include:

Field . . . Contains . . .

The number of seconds which have elapsed in the current 15-minute interval. Maximum value is 900 seconds (15 minutes). This counter is reset every 15 minutes. When zero, the port is disabled.

Payload Rate The rate of data transfer.

DSL Line Rate The rate of the DSL line.

Viewing DSX-1 Performance Statistics

DSX-1 performance statistics allow you to monitor the current status of the DSX-1 interface when ESF framing is selected.

To view DSX-1 Performance Statistics, follow this menu selection sequence:

Main Menu→Status→Performance Statistics→DSX-1 Statistics

main/status/performance/DSX-1 Hotwire Slot: 4 Model: 8784 Port: 2 DSX-1 PERFORMANCE STATISTICS

Current Interval Timer: 2 Error Events Counter: 0000 --ES-- --UAS-- --SES-- --BES-- --LOFC-- --STATUS--

Current Int: 000 Y Interval 01 000 none Interval 02 000 none Interval 03 000 none Interval 04 000 none Interval 05 000 none Interval 06 000 none Interval 07 000 none

Worst Interval24 14 14 09 18 Tot(valid 96): 00010 00000 00000 00000 002

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit PgUp PgDn ClrStats

The following DSX-1 Performance Statistics are collected:

„ ES (Errored Seconds): Seconds during which one or more error events occurred.

„ UAS (Unavailable Seconds): Seconds during which service is unavailable. UAS is received at the start of 10 consecutive SES and cleared at the start of 10 seconds with no SES.

„ SES (Severely Errored Seconds): Seconds during which 320 or more cyclic redundancy check (CRC) error events or at least one Out of Frame (OOF) event occurred.

8784-A2-GB20-30 February 2001 4-11

Current Interval Timer

Page 48 of the Paradyne 8784 user manual — Viewing DSX-1 Performance Statistics
Page 48 · click to enlarge
Page 48
4. Monitoring the Unit

„ BES (Bursty Errored Seconds): Contains the number of bursty errored seconds for the current interval. A bursty errored second is any second with more than one but less than 320 CRC errors.

„ LOFC (Loss of Frame Count): Contains the number of times that an LOF is declared.

„ Status: Contains the contents of the status events register. The status events register maintains a history of specific events that have occurred during an interval. Values include:

— YRemote alarm indication signal (yellow alarm) received at the DSX-1 interface
— LLoss of signal detected at the DSX-1 interface
— EExcessive error rate threshold exceeded
— FFrame synchronization bit error detected
— VLine code violation detected
— NoneNo significant events have occurred

Fields on this screen include:

This Field . . . Contains . . .

The number of seconds which have elapsed in the current 15-minute interval. Maximum value is 900 seconds (15 minutes). This counter resets every 15 minutes.

A running total of CRC and OOF events. Total range = 0–65535. Counter resets when the statistics are cleared.

Current Int Performance data for the current 15-minute interval.

Interval xx Historical performance data for up to 96 15-minute intervals (24 hours) where the value of xx is from 01 to 96.

Worst Interval Identifies the interval during which the most error events were detected.

4-12 February 2001 8784-A2-GB20-30

Current Interval Timer · Error Events Counter

Page 49 of the Paradyne 8784 user manual — Viewing LED Status
Page 49 · click to enlarge
Page 49
4. Monitoring the Unit

Viewing LED Status

The status of the front panel LEDs can be viewed locally and remotely on the Display LEDs status screen.

The LEDs are organized into three groups:

„ General LEDs display the status of the unit

„ DSX-1 LEDs provide the status of the DSX-1 interface

„ DSL Loop LEDs display the activity on the DSL network

To view the Display LEDs status screen, follow this menu selection sequence:

Main Menu→Status→Display LEDs

main/status/leds Hotwire Model8784

GENERAL DSX-1 DSL LOOP ALRM:Off P1:Lnk Up P1:Lnk Up TEST:On P2:Lnk Up P2:Lnk Up

ESC for previous menu MainMenu Exit

The LED status display screen is updated every 5 seconds. For information about the meaning of the LEDs, see Front Panel LEDs on page 4-14.

8784-A2-GB20-30 February 2001 4-13

DISPLAY LEDs

Page 50 of the Paradyne 8784 user manual — DSL PORT
Page 50 · click to enlarge
Page 50
4. Monitoring the Unit

Front Panel LEDs

The following table describes the meaning and states of the LEDs on the faceplate.

SYSTEM

Type LED LED is . . .* Indicating . . .

OK

Device failure; system processing has stopped.

No power is being delivered to the card.

DSX-1

Unit is in minimum mode and a download is required.

Normal operation.

Device failure, or the Power-On Self-Test (POST) has failed.

DSL PORT

No alarms exist.

Loopback test or 511 test pattern is in progress.

POST is in progress.

No tests are active.

DSX-1 1, 2 (Green)

Recoverable signal is present on the DSX-1 interface.

Yellow Alarm Indication (RAI) is present.

An OOF, LOF, EER, or AIS condition exists.

No signal is detected on the interface.

DSL PORT 1, 2 (Green)

DSL link is up.

DSL training is in progress.

OOF condition exists.

DSL link is down.

* Slow Cycling: LED turns off and on in equal duration once per second. Fast Cycling: LED turns off and on in equal duration 5 times per second. Pulsing: LED turns off momentarily once per second. TDM SDSL

4-14 February 2001 8784-A2-GB20-30

Show 23 more labels / short text on this page
SYSTEM OK (Green) · On · Alrm · Test · Off · Slow Cycling · Pulsing · Alrm (Amber) · On · Off · Test (Amber) · On · Slow cycling · Off · On · Slow cycling · Fast cycling · Off · On · Slow cycling · Fast cycling · Off · 00-16144a-01
Page 51 of the Paradyne 8784 user manual — TEST
Page 51 · click to enlarge
Page 51

Testing

Accessing the Test Menu

From the Test menu, you can run network tests, data port tests, a lamp test for the front panel LEDs, or abort all tests.

To access the Test menu, follow this menu selection sequence:

Main Menu→Test

main/test Hotwire Slot4 Model: 8784

TEST

Network & DSX-1 Tests Device Tests

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Select . . . To . . .

Network & DSX-1 Tests Start and stop tests on the network or DSX-1 interface.

Device Tests Start and stop lamp test.

Abort All Tests To abort current tests excluding Network-initiated loopback tests. An aborted test may continue to run for a few seconds as the abort command is sent to the remote end and processed.

8784-A2-GB20-30 February 2001 5-1

Abort All Tests

Page 52 of the Paradyne 8784 user manual — NETWORK & DSX-1 TESTS
Page 52 · click to enlarge
Page 52
5. Testing

Running Network Tests

Network tests require the participation of your network service provider.

To access the Network & DSX-1 Tests screen, follow this menu selection sequence:

Main Menu→Test→Network & DSX-1 Tests

main/test/network_DSX1 Hotwire Slot4 Model: 8784 Port: 2

NETWORK & DSX-1 TESTS

Test Command Status Results Local Loopbacks Line Loopback: Start Inactive 00:00:00 DSX-1 Repeater Loopback: Start Inactive 00:00:00 DSX-1 DTE Loopback: Start Inactive 00:00:00

Remote Loopbacks Send Line LoopbackDown Send Inactive 00:00:00

Pattern Tests Send and Monitor 511 Stop Active hh:mm:ss - Errors 99999+

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit ResetMon

Use the Command column to start or stop a test. When the Status column shows that a test is Inactive, Start is displayed; when a test is Active, Stop is displayed. Position the cursor at the desired Start or Stop command and press Enter. The Results column displays the test duration.

When the Send and Monitor 511 test is active, ResetMon is available to reset the error counter to zero.

Selecting Abort All Tests from the Test menu will not disrupt a Send and Monitor 511 test.

5-2 February 2001 8784-A2-GB20-30

Page 53 of the Paradyne 8784 user manual — CAP
Page 53 · click to enlarge
Page 53
5. Testing

Line Loopback

A Line Loopback (LLB) loops the received signal on the network interface back to the network without change.

CAP

CAP T1

LIU

AIS

Procedure

To run a Line Loopback:

1. Position the cursor at the Start command next to Line Loopback on the Network & DSX-1 Tests screen.
2. Press Enter.

The Start command is changed to Stop.

3. To manually stop the test, verify that the cursor is positioned at the Stop command.
4. Press Enter.

The Line Loopback cannot be started when another loopback or pattern test is in progress.

8784-A2-GB20-30 February 2001 5-3

Show 4 more labels / short text on this page
DSL Port · DSX-1 Port · Framer Framer Transceiver · 98-16112
Page 54 of the Paradyne 8784 user manual — NOTE:
Page 54 · click to enlarge
Page 54
5. Testing

Repeater Loopback

A Repeater Loopback (RLB) loops the signal being sent from the DSX-1 port back to the DSX-1 port.

CAP

CAP T1

LIU

AIS

T1-to-T1 Repeater Loopback

CAP

CAP T1

LIU

T1-to-V.35 Repeater Loopback

Procedure

To run a Repeater Loopback:

1. Position the cursor at the Start command next to Repeater Loopback on the Network & DSX-1 Tests screen.
2. Press Enter.

The Start command is changed to Stop.

3. To manually stop the test, verify that the cursor is positioned at the Stop command.
4. Press Enter.

The Repeater Loopback cannot be started when any other loopback test is in progress.

NOTE:

Activating the Repeater Loopback test causes the Embedded Operations Channel (EOC), used for management, to be lost to the remote unit.

5-4 February 2001 8784-A2-GB20-30

Show 8 more labels / short text on this page
DSL Port · DSX-1 Port · Framer Framer Transceiver · 99-16417 · DSL Port · DSX-1 Port · Framer Framer Transceiver · 99-16418
Page 55 of the Paradyne 8784 user manual — CAP
Page 55 · click to enlarge
Page 55
5. Testing

DTE Loopback

A DTE Loopback loops the DSX-1 signal back to itself before the signal is sent to the Framer.

CAP

CAP T1

LIU

Procedure

To run a DTE Loopback:

1. Position the cursor at the Start command next to DTE Loopback on the Network & DSX-1 Tests screen.
2. Press Enter.

The Start command is changed to Stop.

3. To manually stop the test, verify that the cursor is positioned at the Stop command.
4. Press Enter.

The DTE Loopback cannot be started when any other loopback test is in progress.

8784-A2-GB20-30 February 2001 5-5

Show 5 more labels / short text on this page
DSL Port · DSX-1 Port · All Ones · Framer Framer Transceiver · 98-16110
Page 56 of the Paradyne 8784 user manual — CAP CAP T1
Page 56 · click to enlarge
Page 56
5. Testing

Remote Send Line Loopback

The local unit initiates this test by sending a line loopback Up or Down command to the remote unit for 10 seconds. When the remote unit detects the loopback Up command, it puts itself in line loopback and lights the front panel Test LED. The remote unit remains in loopback until it receives a loopback Down command or the remote unit's test timeout value is exceeded.

The Send Line Loopback tests both units. External equipment can be used to verify the link.

CAP CAP T1

CAP

CAP T1

AIS

LIU

LIU

Procedure

To run a Remote Send Line loopback:

1. Position the cursor at the Up or Down selection next to Send Line Loopback on the Network & DSX-1 Tests screen.
2. Press the spacebar to select either Up or Down.
3. Position the cursor at the Send command next to Up or Down selection.
4. Press Enter.

The local unit stops sending the loopback command automatically after 10 seconds. You cannot stop the Remote Send Line Loopback test manually.

The Remote Send Line Loopback cannot be started when any other loopback or a Send and Monitor 511 test is active on the network interface.

5-6 February 2001 8784-A2-GB20-30

Show 5 more labels / short text on this page
Local Remote · DSX-1 Port · Framer Framer Transceiver · Framer Framer Transceiver · 98-16109
Page 57 of the Paradyne 8784 user manual — CAP CAP T1
Page 57 · click to enlarge
Page 57
5. Testing

Send and Monitor 511

The Send and Monitor 511 test causes the local and remote units to send a 511 test pattern to each other. The front panel Test LEDs of both units are on during the test. The duration and results of the test are displayed on the Network & DSX-1 Tests screen of the initiating unit.

NOTE:

The Send and Monitor 511 test is not a loopback test. Each unit independently sends and monitors a 511 pattern.

CAP CAP T1

CAP

CAP T1

AIS AIS

LIU

LIU

Procedure

To run a Send and Monitor 511 test:

1. Position the cursor at the Start command next to Send and Monitor 511 on the Network & DSX-1 Tests screen.
2. Press Enter.

The Start command is changed to Stop.

3. To manually stop the test, verify that the cursor is positioned at the Stop command.
4. Press Enter.

When a Send and Monitor 511 test is active, a count of bit errors is displayed next to the test duration, and the ResetMon virtual function key is available for use. Type r or R or select the ResetMon virtual function key to reset the error count.

8784-A2-GB20-30 February 2001 5-7

Show 10 more labels / short text on this page
511 Pattern · 511 Gen · 511 Mon · 511 Pattern · DSX-1 Port · 511 Mon · 511 Gen · Framer Framer Transceiver · Framer Framer Transceiver · 98-16108
Page 58 of the Paradyne 8784 user manual — Procedure
Page 58 · click to enlarge
Page 58
5. Testing

Device Tests

The Device Tests menu lists a single, card-level test, the Lamp Test. To access the Device Tests screen, follow this menu selection sequence:

Main Menu→Test→Device Tests

main/test/card Hotwire Slot4 Model: 8784

DEVICE TESTS

Test Command Status Lamp Test: Start Inactive

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Lamp Test

The Lamp Test determines whether all LEDs are lighting and functioning properly.

Procedure

To test the LEDs:

1. Position the cursor at the Start command next to Lamp Test on the Device Tests screen.
2. Press Enter.

The Start command is changed to Stop. During the Lamp Test, all LEDs blink simultaneously every second. When you stop the Lamp Test, the LEDs are restored to their normal condition.

3. To stop the Lamp Test, position the cursor at the Stop command.
4. Press Enter.

5-8 February 2001 8784-A2-GB20-30

Page 59 of the Paradyne 8784 user manual — Ending an Active Test
Page 59 · click to enlarge
Page 59
5. Testing

Ending an Active Test

Except for the Remote Send Line Loopback, a test initiated by the user can be ended by the user.

A test initiated by the user can be ended using:

„ Test Timeout option – Enable the Test Timeout system option so the unit can automatically terminate tests, and set the Test Duration (min) option to specify the amount of time that tests can run before the unit terminates the test. The default is 10 minutes. Refer to Table A-4, System Options, in Appendix A, Configuration Options.

„ Command column – Under the Command column on any test screen, position the cursor at Stop next to the active test and press Enter to stop a specific test.

„ Abort All Tests menu selection – Select Abort All Tests from the Test menu to stop all tests running on all interfaces. Command Complete appears when all tests on all interfaces have been terminated. Network-initiated loopbacks cannot be stopped from the Test menu.

An aborted test may continue to run for a few seconds as the Stop command is sent to the remote end and processed.

8784-A2-GB20-30 February 2001 5-9

Page 60 of the Paradyne 8784 user manual — CAP
Page 60 · click to enlarge
Page 60
5. Testing

Telco-Initiated Tests

The Hotwire 8784 TDM SDSL Termination Unit supports Telco-initiated tests as shown in the following table.

Activation and Deactivation

Line Loopback

Payload Loopback

Remote Line Loopback

In-Band Signal Supported Not Applicable Not Supported

Bit-Oriented Supported Supported Supported

Message-Oriented Not Applicable Not Supported Not Applicable

Telco-Initiated Line Loopback

The Hotwire 8784 Termination Unit supports line loopback as specified in AT&T TR 54016, AT&T TR 62411, and ANSI T1.403. A Telco-initiated line loopback loops the received signal on the DSX-1 interface back to the DSX-1 interface without modification. Framing, CRC, and FDL bits are returned unaltered, and no BPVs or other line coding errors are removed.

CAP

CAP T1

LIU

Telco-Initiated Payload Loopback

The Hotwire 8784 Termination Unit supports payload loopback as specified in AT&T TR 54016 and ANSI T1.403. A Telco-initiated line loopback loops the received signal on the DSX-1 interface back to the DSX-1 interface. Framing, CRC, and FDL bits are regenerated at the point of the loopback, and BPVs are removed.

CAP

CAP T1

LIU

5-10 February 2001 8784-A2-GB20-30

Show 10 more labels / short text on this page
DSL Port · DSX-1 Port · All Ones Telco · Framer Framer Transceiver · 99-16252 · DSL Port · DSX-1 Port · All Ones Telco · Framer Framer Transceiver · 99-16253
Page 61 of the Paradyne 8784 user manual — CAP CAP T1
Page 61 · click to enlarge
Page 61
5. Testing

Telco-Initiated Remote Line Loopback

If Remote Telco Loopback is enabled, a Telco-initiated line loopback loops received data at the remote unit and passes it back to the Telco through the local unit.

The following figure shows the data flow for a remote Telco-initiated payload loopback.

CAP CAP T1

CAP

CAP T1

LIU

DSL

LIU

AIS

8784-A2-GB20-30 February 2001 5-11

Show 7 more labels / short text on this page
Local Remote · DSX-1 Port · DSX-1 Port · Telco · Framer Framer Transceiver · Framer Framer Transceiver · 98-16109
Page 62 of the Paradyne 8784 user manual — Telco-Initiated Remote Line Loopback
Page 62 · click to enlarge
Page 62
5. Testing

5-12 February 2001 8784-A2-GB20-30

Page 63 of the Paradyne 8784 user manual — Messages and Troubleshooting
Page 63 · click to enlarge
Page 63

Messages and Troubleshooting

Overview

There are many messages available to assess the status of the device and contribute to problem resolutions. Refer to the following sections:

„ Configuring SNMP Traps on page 6-2

„ Device Messages on page 6-3

„ Troubleshooting on page 6-5

8784-A2-GB20-30 February 2001 6-1

Page 64 of the Paradyne 8784 user manual — SNMP TRAPS OPTIONS
Page 64 · click to enlarge
Page 64
6. Messages and Troubleshooting

Configuring SNMP Traps

An SNMP trap can be automatically sent out through the EOC or the Management port to the SNMP manager when the termination unit detects conditions set by the user. These traps enable the SNMP manager to gauge the state of the network. Refer to Appendix B, Standards Compliance for SNMP Traps, for details of SNMP traps supported by the unit.

To configure the unit for SNMP traps, use the SNMP Traps Options screen to:

„ Enable SNMP traps.

„ Set the number of SNMP managers that receive SNMP traps from the unit.

„ Enter an IP address and network destination for each SNMP manager specified.

„ Select the type of SNMP traps to be sent from the unit.

To configure SNMP Traps, follow this menu selection sequence:

Main Menu→Configuration→Current Configuration→ Management and Communication→SNMP Traps

main/config/management/trap Hotwire Slot4 Model: 8784

SNMP TRAPS OPTIONS

SNMP TrapsEnable Number of Trap Managers: 5

NMS 1 IP Address: 135.014.040.001 Clear Destination: IMC NMS 2 IP Address: 135.014.003.027 Clear Destination: IMC NMS 3 IP Address: 135.014.001.008 Clear Destination: IMC NMS 4 IP Address: 135.014.002.024 Clear Destination: IMC NMS 5 IP Address: 204.128.146.035 Clear Destination: IMC

General TrapsBoth Enterprise Specific Traps: Enable Link Traps: Both Link Traps Interfaces: Network

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

Refer to Table A-8, SNMP Trap Options, in Appendix A, Configuration Options, to configure SNMP traps.

6-2 February 2001 8784-A2-GB20-30

Page 65 of the Paradyne 8784 user manual — Table 6-1. Device Messages (1 of 2)
Page 65 · click to enlarge
Page 65
6. Messages and Troubleshooting

Device Messages

The Device Messages in Table 6-1, Device Messages, listed in alphabetical order, may appear in the messages area at the bottom of the ATI screens.

Table 6-1. Device Messages (1 of 2)

Device Message What Message Indicates What To Do

Access level is Operator. Configuration is read-only.

The operator requested that configuration options be loaded, but does not have authority to edit them.

If configuration options are to be edited, use a Login ID that has Administrator authority.

Cannot Save – no Login IDs with Access Administrator

All of the login IDs being saved have an access level below Administrator.

Change the access level of at least one Login ID to Administrator so that configuration changes can be made. (Operator-level users cannot make configuration changes.) Save the Login IDs.

Command Complete Action requested has successfully completed.

No action is needed.

Invalid Character (x) A nonprintable ASCII character (x) has been entered.

Re-enter information using valid characters.

Invalid Password Login is required and an incorrect password was entered; access is denied.

„ Try again.

„ Contact your system

administrator to verify your password.

Invalid – Send Pattern Already Active

A pattern test was already in progress when the Start field was selected.

„ Allow test to continue.

„ Select another test.

„ Stop the test.

Invalid – [Test] Already Active

The described test was already in progress when another selection was made.

„ Allow test to continue.

„ Select another test.

„ Stop the test.

A loopback or pattern test was in progress when Start was selected to start another test, or was active on the same or another interface when Start was selected.

„ Wait until other test ends and

message clears.

„ Abort all tests from the Test

menu screen.

„ Stop the test from the same

screen the test was started from.

IP address not in MCC subnet nnn.nnn.nnn.nnn

The Peer IP address specified is not in the same subnet as the MCC.

Enter an IP address that is in the same subnet as the MCC.

8784-A2-GB20-30 February 2001 6-3

Invalid Test Combination

Page 66 of the Paradyne 8784 user manual — Table 6-1. Device Messages (2 of 2)
Page 66 · click to enlarge
Page 66
6. Messages and Troubleshooting

Table 6-1. Device Messages (2 of 2)

Device Message What Message Indicates What To Do

Limit of six Login IDs reached

An attempt to enter a new login ID was made, and the limit of six login/password combinations has been reached.

1. Delete another login/password combination.
2. Re-enter the new login ID.

No Security Records to Delete

Delete was selected from the Administer Login screen, and no security records had been defined.

„ No action is needed.

„ Enter a security record.

Password Matching Error – Re-enter Password

Password entered in the Re-enter Password field of the Administer Logins screen does not match what was entered in the Password field.

„ Try again.

„ Contact your system

administrator to verify your password.

Please Wait Command takes longer than 5 seconds. Wait until message clears.

Test Active A test is running and no higher priority health and status messages exist.

„ Contact service provider if

test initiated by the network.

„ Wait until the other test ends

and message clears.

„ Cancel all tests from the Test

screen.

„ Stop the test from the same

screen the test was started from.

0.0.0.0 is an invalid IP address

An IP address of all zeros was entered.

Enter a valid, non-zero IP address.

6-4 February 2001 8784-A2-GB20-30

Page 67 of the Paradyne 8784 user manual — Table 6-2. Troubleshooting
Page 67 · click to enlarge
Page 67
6. Messages and Troubleshooting

Troubleshooting

The unit is designed to provide many years of trouble-free service. However, if a problem occurs, refer to Table 6-2, Troubleshooting, for possible solutions.

Table 6-2. Troubleshooting

Symptom Possible Cause Solutions

Alarm LED is on. A system failure has occurred.

Refer to Table 4-1, Health and Status Messages, in Chapter 4, Monitoring the Unit, for the recommended action.

Cannot access the unit via the ATI.

The terminal is not set up for the correct rate or data format, or the unit is configured so it prevents access.

„ Check the cable and

connections.

„ Ensure that the unit is

configured properly in the DSLAM. Verify its IP address.

„ Reset the unit.

Device Fail appears on the System and Test Status screen under Self-Test results.

The unit detects an internal hardware failure.

„ Reset the unit.

„ Contact your service

representative.

No power, or the LEDs are not lit.

The unit is not properly seated in the DSLAM.

Verify that the unit is properly inserted.

There is no power to the DSLAM.

Verify that the DSLAM has power.

An LED is not lit. LED is out. Run the Lamp Test. If the LED in question does not flash with the other LEDs, then contact your service representative.

Not receiving data. The network or DSX-1 port cables are not connected (check front panel LEDs for more information).

„ Check network and DSX-1

port cables.

„ Check Health and Status

menu.

„ Run Loopback tests. Refer to

Chapter 5, Testing.

A test is being executed on the unit (check the TEST LED on the front panel).

Stop the test or wait for the test to end.

The far-end device is offline. Make sure the far-end device is on.

Power-On Self-Test fails. Only Alarm LED is on after power-on.

The unit has detected an internal hardware failure.

„ Reset the unit and try again.

„ Contact your service

representative.

8784-A2-GB20-30 February 2001 6-5

Page 68 of the Paradyne 8784 user manual — Troubleshooting
Page 68 · click to enlarge
Page 68
6. Messages and Troubleshooting

6-6 February 2001 8784-A2-GB20-30

Page 69 of the Paradyne 8784 user manual — Table 7-1. Access Levels
Page 69 · click to enlarge
Page 69

Security

Overview

The termination unit provides several methods of security by limiting user access to the ATI through option settings. You can:

„ Enable the Telnet Login Required option.

„ Limit the access by setting a Session Access Level option of Operator for the Telnet Session.

„ Disable the access with the Telnet Session option.

See Table A-5, Telnet Session Options, in Appendix A, Configuration Options.

ATI Access Levels

The unit has two access levels: Administrator and Operator. The access level determines what functions are accessible, as shown in Table 7-1, Access Levels.

Table 7-1. Access Levels

ATI Access to Menu Functions Administrator Operator

Test Full Access No Access

Configuration Full Access Read-Only

Control Full Access No Access

Access level is also used to control access via Telnet. If the Telnet Session Access Level is set to Administrator, a Login ID with an Operator access level is not permitted access (see Table A-5, Telnet Session Options, in Appendix A, Configuration Options).

The effective access level is the more restrictive of the session access level or the login access level.

8784-A2-GB20-30 February 2001 7-1

Status Read-Only Read-Only

Page 70 of the Paradyne 8784 user manual — LOGIN ENTRY
Page 70 · click to enlarge
Page 70
7. Security

Creating a Login

Logins apply to Telnet access directly to the Hotwire 8784 Termination Unit. The Administer Logins menu option is not presented when you access the unit through the MCC.

Six login ID/password combinations are available. Each Login ID and Password must be unique and include an access level.

Procedure

1. To create a login record, follow this menu selection sequence:

Main Menu→Control→Administer Logins

main/control/admin_logins Hotwire Slot4 Model: 8784

ADMINISTER LOGINS Page 1 of 1

Login IDnewuser Access Level: Administrator

Are You Sure? Yes

ESC for previous menu MainMenu Exit Save PgUp PgDn New Delete

2. Select New and press Enter. The Login Entry screen is displayed.
main/control/admin_logins Hotwire Slot4 Model: 8784

LOGIN ENTRY

Login IDnewuser Password: e34t136 Re-enter Password: e34t136 Access Level: Administrator

Ctrl-a to access these functions ESC for previous menu MainMenu Exit Save PgUp PgDn New Delete

7-2 February 2001 8784-A2-GB20-30

Page 71 of the Paradyne 8784 user manual — Procedure
Page 71 · click to enlarge
Page 71
7. Security
3. Create the login by entering the following fields. Login IDs and passwords are case-sensitive.

On the Login Entry screen, for the . . . Enter . . .

Login ID 1 to 10 ASCII printable characters (hex21 through 7E). Blanks are not allowed.

Password 1 to 10 ASCII printable characters that can consist of 0–9, a– z, A–Z, # (pound), . (period), – (dash), and / (slash).

Re-enter Password 1 to 10 ASCII printable characters that can consist of 0–9, a– z, A–Z, # (pound), . (period), – (dash), and / (slash).

Access Level Administrator, Operator

NOTE:

Assign at least one Administrator-level Login ID. Full access is necessary to make configuration option changes and administer logins.

4. Press Ctrl-a to switch to the function keys area below the dotted line. Select Save and press Enter.
5. When Save is complete, Command Complete appears at the bottom of the screen.
6. If additional logins are required, repeat Steps 3 through 5.
7. When all logins are entered, press Esc to return to the Administer Logins screen.
8. Select Save and press Enter.

Deleting a Login

Procedure

1. To delete a login record, follow this menu selection sequence:

Main Menu→Control→Administer Logins

2. Select PgUp or PgDn and press Enter to page through login pages/records until you find the one to be deleted.
3. Once the correct record is displayed, select Delete and press Enter.
4. To complete the delete action, select Save and press Enter.

When the deletion is complete, Command Complete appears at the bottom of the screen. The number of login pages/records reflects one less record, and the record following the deleted record appears.

8784-A2-GB20-30 February 2001 7-3

Page 72 of the Paradyne 8784 user manual — NOTE:
Page 72 · click to enlarge
Page 72
7. Security

Controlling SNMP Access

There are three methods for limiting SNMP access.

„ Disable the SNMP management option. Refer to Table A-6, General SNMP Management Options, in Appendix A, Configuration Options.

„ Assign SNMP community names and access types.

„ Limit SNMP access through validation of the IP address of each allowed SNMP manager.

Assigning SNMP Community Names and Access Types

The unit can be managed by an SNMP manager supporting SNMP. The community name must be supplied by an external SNMP manager accessing an object in the MIB.

To define SNMP community names, follow this menu selection sequence:

Main Menu→Configuration→Current Configuration→ Management and Communication→General SNMP Management

Refer to Table A-6, General SNMP Management Options, in Appendix A, Configuration Options, to:

„ Enable SNMP Management.

„ Assign the SNMP community names of the SNMP Managers that are allowed to access the units Management Information Base (MIB).

„ Specify Read or Read/Write access for each SNMP community name.

Limiting SNMP Access through the IP Addresses of the Managers

The unit provides an additional level of security through validation of the IP addresses.

The SNMP Management option must be enabled. To control SNMP access with IP addresses, follow this menu selection sequence:

Main Menu→Configuration→Current Configuration→ Management and Communication→SNMP NMS Security

Refer to Table A-7, SNMP NMS Security Options, in Appendix A, Configuration Options. The SNMP access can be limited by:

„ Enabling NMS IP address checking.

„ Add each IP address and access level.

NOTE:

Do not change or delete the IP address or access level of the NMS performing the sets or enable IP address checking prior to adding the NMS to the table.

7-4 February 2001 8784-A2-GB20-30

Page 73 of the Paradyne 8784 user manual — All Configurations
Page 73 · click to enlarge
Page 73

IP Addressing

Selecting an IP Addressing Scheme

Your IP addressing scheme depends in part whether the MCC controlling the chassis is running IP Conservative software.

Configurations Not Running IP Conservative Software

In a configuration not running IP Conservative software, the NTU’s network interface IP address is assigned through the peer IP address of the LTU’s Network Interface menu.

The termination unit is assigned an IP address and subnet through the DSLAM Configuration→DSL Cards→Set IP Address menu. Once the address is assigned, you can use the ATI to assign:

„ Peer IP addresses to the two TDM SDSL ports. These addresses are used as the IP addresses of the remote units. See Table A-1, Network Interface Options, in Appendix A, Configuration Options.

„ An IP address for each NMS to act as a trap manager. See Table A-8, SNMP Trap Options, in Appendix A, Configuration Options.

All Configurations

The NTU obtains its IP address when the PPP link is established over the EOC.

Use the ATI to assign:

„ An IP address for each NMS. See Table A-7, SNMP NMS Security Options, in Appendix A, Configuration Options.

„ An IP address for the TFTP server you wish to use to upload and download configurations. See Configuration Loader in Chapter 3, Initial Startup and Configuration, and the documentation for your TFTP server.

8784-A2-GB20-30 February 2001 8-1

Page 74 of the Paradyne 8784 user manual — Figure 8-1. Peer IP Address Assignments
Page 74 · click to enlarge
Page 74
8. IP Addressing

Review the following information in preparation for selecting an IP addressing scheme.

„ Any legal host address is allowed for a given subnet. The address choice within the subnet is arbitrary.

„ A single route to a subnet is all that is needed to reach every device on a subnet. The unit’s routing table supports a maximum of 20 routes.

IP Addressing Example

See Figure 8-1, Peer IP Address Assignments, for an example of an IP addressing scheme. In the example, the Peer IP Address:

„ Refers to the IP address of the unit configured as an NTU.

„ Is assigned by the LTU.

Paradyne 8784 — IP Addressing Example diagram (page 74)
Fig. 4 · IP Addressing Example

Figure 8-1. Peer IP Address Assignments

8-2 February 2001 8784-A2-GB20-30

Page 75 of the Paradyne 8784 user manual — NOTE:
Page 75 · click to enlarge
Page 75

A

Configuration Options

Overview

The tables in this appendix summarize the configuration options accessed when you select Configuration on the Main Menu. The configuration options are arranged into groups based upon functionality.

Select . . . To Access the . . . To Configure the . . .

Network Network Interface Options (Table A-1) DSL network interface Ports 1 and 2.

DSX-1 DSX-1 Interface Options (Table A-2) DSX-1 interface port.

Copy Ports Copy Ports Options (Table A-3) DSL network and DSX-1 interface ports by copying options from port to port.

System System Options (Table A-4) General system options of the unit.

„ Telnet Session Options (Table A-5)

Management support of the unit through SNMP and Telnet.

„ General SNMP Management

Options (Table A-6)

„ SNMP NMS Security Options

(Table A-7)

„ SNMP Trap Options (Table A-8)

NOTE:

All changes to configuration options must be saved. Refer to Saving Configuration Changes in Chapter 3, Initial Startup and Configuration.

8784-A2-GB20-30 February 2001 A-1

Management and Communication

Page 76 of the Paradyne 8784 user manual — Table A-1. Network Interface Options (1 of 2)
Page 76 · click to enlarge
Page 76

A. Configuration Options

Network Interface Options

For Network Interface Options, refer to Table A-1, Network Interface Options. To access the Network Interface Options screen, follow this menu selection sequence:

Main Menu→Configuration→Current Configuration→Network

main/config/network Hotwire Slot 4 Model8784 Port 2

NETWORK INTERFACE OPTIONS

Margin Threshold–3db Excessive Error Rate Threshold: 1E–6 AutoRate: Disable DSL Line Rate: 1552 Kbps
Peer IP Address111.255.255.000 Clear
Circuit IdentifierClear

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

Table A-1. Network Interface Options (1 of 2)

Possible Settings: –5db, –4db, –3db, –2db, –1db, 0db, 1db, 2db, 3db, 4db, 5db,

6db, 7db, 8db, 9db, 10db Default Setting: 0db

Determines the level, expressed in decibels, at which a signal-to-noise margin condition is recognized.

–5db to 10db – Sets the margin threshold to this value.

Excessive Error Rate Threshold

Possible Settings1E–4 , 1E–5 , 1E–6 , 1E–7 , 1E–8 , 1E–9 Default Setting: 1E–6

Determines the error rate at which an excessive error rate (EER) condition is recognized. The rate is the ratio of the number of CRC errors to the number of bits received in a certain period.

1E–4 to 1E–9 – Sets the error rate threshold to this value.

A-2 February 2001 8784-A2-GB20-30

Margin Threshold

Page 77 of the Paradyne 8784 user manual — Table A-1. Network Interface Options (2 of 2)
Page 77 · click to enlarge
Page 77

A. Configuration Options

Table A-1. Network Interface Options (2 of 2)

Possible SettingsEnable, Disable Default Setting: Disable

Determines whether the unit automatically adjusts to the best line rate for conditions, or is fixed at the rate in the DSL Line Rate field. The automatically set rate cannot exceed DSL Line Rate.

„ AutoRate is only available when the unit is configured as an LTU.

Enable – The LTU adjusts to the best line rate.

Disable – The LTU’s line rate is the selected DSL Line Rate.

Possible Settings400, 528, 784, 1040, 1552 Default Setting: 1552

Determines the fixed line rate of the LTU when AutoRate is disabled, and the maximum rate to which the unit can be set when AutoRate is enabled.

„ DSL Line Rate is only available when the unit is configured as an LTU.

400 to 1552 – The fixed DSL Line Rate, in kbps.

Possible Settings001.000.000.000 – 223.255.255.255, Clear Default Setting: 000.000.000.000

Specifies the peer IP address providing the remote management link on the DSL loop.

„ Peer IP Address is only available when the unit is configured as an LTU and the unit

is in not running in IP Conservative mode.

Address Field – (001.000.000.000 – 223.255.255.255) – Enter an address for the peer unit. The range for the first byte is 001 to 223, with the exception of 127. The range for the remaining three bytes is 000 to 255. The IP address must be in the same subnet as the MCC backplane address.

Clear – Clears the IP address and sets to all zeros.

Possible SettingsASCII text field Default Setting: [blank]

Uniquely identifies the circuit number of the transmission vendor’s DSL line for troubleshooting purposes.

ASCII text field – Enter a maximum of 128 characters. All printable ASCII characters except the ^ (caret) are allowed.

Clear – Clears the field.

8784-A2-GB20-30 February 2001 A-3

Show 4 more labels / short text on this page
AutoRate · DSL Line Rate · Peer IP Address · Circuit Identifier
Page 78 of the Paradyne 8784 user manual — DSX-1 Interface Options
Page 78 · click to enlarge
Page 78

A. Configuration Options

DSX-1 Interface Options

For DSX-1 Interface Options, refer to Table A-2, DSX-1 Interface Options. To access the DSX-1 Interface Options screen, follow this menu selection sequence:

Main Menu→Configuration→Current Configuration →DSX-1

main/config/DSX-1 Hotwire Slot 4 Model8784 Port 2 DSX-1 INTERFACE OPTIONS

Port Status: Enable Line Framing: ESF Line Coding: B8ZS Line Equalization: 0-133 Excessive Error Rate Threshold: 1E-4 Send (AIS) on Network Failure: Enable Send All Ones on DSX-1 Failure: Enable

Primary Clock SourceDSX-1

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

A-4 February 2001 8784-A2-GB20-30

Page 79 of the Paradyne 8784 user manual — Table A-2. DSX-1 Interface Options (1 of 2)
Page 79 · click to enlarge
Page 79

A. Configuration Options

Table A-2. DSX-1 Interface Options (1 of 2)

Possible SettingsEnable, Disable Default Setting: Enable

Determines whether the port can be configured and used.

Enable – The port can be configured and used.

Disable – The port cannot be configured or used. Configuration fields for the port are inaccessible, no alarms or traps associated with the port are generated, and the LED associated with the port is OFF.

Possible SettingsESF, D4 Default Setting: ESF

Specifies the framing format to be used by the DSX-1 interface.

„ Line Framing is only available when the unit is configured as an LTU. The NTU is

automatically configured to match the framing format used by the LTU.

ESF – ESF framing formatting is used for transmitted and received data over the DSX-1 Interface.

D4 – D4 framing format is used for transmitted and received data over the DSX-1 Interface.

Possible SettingsAMI, B8ZS Default Setting: B8ZS

Specifies the line coding format to be used by the DSX-1 interface.

AMI – Indicates the line coding format used by the DSX-1 interface is Alternate Mark Inversion (AMI).

B8ZS – Indicates the line coding format used by the DSX-1 interface is B8ZS.

Possible Settings0–133, 133–266, 266–399, 399–533, 533–655 Default Setting: 0–133

Compensates for signal distortion for a DSX-1 signal over a given distance.

0–133 feet – Provides equalization for a cable length up to 133 feet. 133–266 feet – Provides equalization for a cable length up to 266 feet. 266–399 feet – Provides equalization for a cable length up to 399 feet. 399–533 feet – Provides equalization for a cable length up to 533 feet. 533–655 feet – Provides equalization for a cable length up to 655 feet.

Excessive Error Rate Threshold

Possible Settings: 1E– 4, 1E–5, 1E– 6, 1E–7, 1E– 8, 1E–9 Default Setting: 1E–4

Determines the error rate at which an excessive error rate (EER) condition is recognized. The rate is the ratio of the number of CRC5 errors to the number of bits received in a certain period.

1E–4 – 1E-9 – The rate at which EER is recognized.

8784-A2-GB20-30 February 2001 A-5

Show 4 more labels / short text on this page
Port Status · Line Framing · Line Coding · Line Equalization
Page 80 of the Paradyne 8784 user manual — Table A-2. DSX-1 Interface Options (2 of 2)
Page 80 · click to enlarge
Page 80

A. Configuration Options

Table A-2. DSX-1 Interface Options (2 of 2)

Send (AIS) on Network Failure

Possible SettingsEnable, Disable Default Setting: Enable

Specifies the action taken on the signal transmitted to the DSX-1 when a valid signal cannot be recovered from the network interface (LOS or OOF).

Enable – An Alarm Indication Signal (AIS) is sent to the DSX-1 port in the event of an LOS or OOF condition on the network interface.

Disable – The failed signal on the interface is passed through to the DSX-1 network unchanged.

Send All Ones on DSX-1 Failure

Possible SettingsEnable, Disable Default Setting: Enable

Specifies the action taken on the signal transmitted to the network when a valid signal cannot be recovered from the network interface (LOS or OOF).

Enable – A pattern of all ones is sent to the DSX-1 port in the event of an LOS or LOF condition on the DSX-1 interface.

Disable – The failed signal on the interface is passed through to the DSX-1 network unchanged.

Possible SettingsDSX-1, Internal Default Setting: Internal

Determines the primary clock source for the unit in Bypass mode.

„ Primary Clock Source is available only when the unit is configured as an LTU. If

DSL Line Rate is set lower than 1552 kbps, Primary Clock Source is forced to DSX-1 and cannot be changed.

Internal – The clock source is derived from the internal oscillator.

DSX-1 – The clock source is derived from the DSX-1 interface.

A-6 February 2001 8784-A2-GB20-30

Primary Clock Source

Page 81 of the Paradyne 8784 user manual — Table A-3. Copy Ports Options
Page 81 · click to enlarge
Page 81

A. Configuration Options

Copy Ports Options

You can copy the configuration options of one DSX-1 interface and DSL loop to another using the Copy Ports screen. For Copy Ports options, refer to Table A-3, Copy Ports Options. To access the Copy Ports screen, follow this menu selection sequence:

Main Menu→Configuration→Current Configuration→Copy Ports

main/config/copy Hotwire Slot 4 Model8784

COPY PORTS

FromPort 1: To: Port 2:

Perform Copy Then Increment

ESC for previous menu MainMenu Exit Save

Table A-3. Copy Ports Options

FromPort n
Possible Settings1 , 2 Default Setting: 1

Controls the source of the configuration options.

1 to 2 – The configuration of the selected port is copied.

ToPort y
Possible Settings1 , 2 , All Default Setting: 2

Controls the target of the configuration options.

1 to 2 – The configuration of the selected port is replaced. If Perform Copy Then Increment is selected, the port number is incremented by 1 after the copy.

All – The configurations of all ports are replaced by the configuration of the selected From: Port.

8784-A2-GB20-30 February 2001 A-7

Perform Copy

Page 82 of the Paradyne 8784 user manual — SYSTEM OPTIONS
Page 82 · click to enlarge
Page 82

A. Configuration Options

System Options

For System Options, refer to Table A-4, System Options. To access the System Options screen, follow this menu selection sequence:

Main Menu→Configuration→Current Configuration→System

main/config/system Hotwire Slot 4 Model8784

SYSTEM OPTIONS

DSL Mode: LTU Test Timeout: Enable Test Duration (min): 10 Telco Initiated Loopbacks: Enable Remote Telco Line Loopback: Disabled

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

A-8 February 2001 8784-A2-GB20-30

Page 83 of the Paradyne 8784 user manual — Table A-4. System Options
Page 83 · click to enlarge
Page 83

A. Configuration Options

Table A-4. System Options

Possible SettingsLTU , NTU Default Setting: LTU

Controls whether the unit is configured as a control unit or tributary unit.

LTU – The unit is configured as a control unit (Line Termination Unit).

NTU – The unit is configured as a tributary unit (Network Termination Unit). This unit will request its IP address from the LTU during establishment of the PPP link.

Possible SettingsEnable , Disable Default Setting: Enable

Allows tests to end automatically. The feature should be enabled when the unit is remotely managed, so that control can be regained after a test is accidentally executed.

Enable – Loopback and pattern tests end when test duration is reached.

Disable – Tests run until manually terminated from the Network Tests screen or remotely (network initiated tests). Refer to Running Network Tests in Chapter 5, Testing.

Possible Settings1 – 120 Default Setting: 10

Number of minutes for a test to be active before automatically ending.

„ Test Duration (min) option appears when Test Timeout is enabled.

1. 120 – Amount of time in minutes for a test to run before terminating.
Possible SettingsEnable , Disable Default Setting: Enable

Determines if the unit will respond to Telco loopback commands on the DSX-1 interface. See Telco-Initiated Tests in Chapter 5, Testing.

Enable – The unit will respond to Telco loopback commands.

Disable – The unit will not respond to Telco loopback commands.

Remote Telco Line Loopback

Possible SettingsEnable , Disable Default Setting: Disable

Determines if the unit will perform a Telco initiated loopback on just the local unit or if the loopback will be performed on the remote DSL unit. See Telco-Initiated Tests in Chapter 5, Testing.

Enable – The loopback will be in the remote unit.

Disable – The loopback will be local.

8784-A2-GB20-30 February 2001 A-9

Show 4 more labels / short text on this page
DSL Mode · Test Timeout · Test Duration (min) · Telco Initiated Loopback
Page 84 of the Paradyne 8784 user manual — TELNET SESSION OPTIONS
Page 84 · click to enlarge
Page 84

A. Configuration Options

Management and Communication Menu

The Management and Communication Menu includes the following:

„ Telnet Session Options (Table A-5)

„ General SNMP Management Options (Table A-6)

„ SNMP NMS Security Options (Table A-7)

„ SNMP Trap Options (Table A-8)

Telnet Session Options

To access the Telnet Sessions Options screen, follow this menu selection sequence:

Main Menu→Configuration→Current Configuration→ Management and Communication→Telnet Session

main/config/management/telnet Hotwire Slot 4 Model: 8784

TELNET SESSION OPTIONS

Telnet Session: Enable Telnet Login Required: Enable Session Access Level: Administrator Inactivity Timeout: Enable Disconnect Time (Minutes) 5

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

A-10 February 2001 8784-A2-GB20-30

Page 85 of the Paradyne 8784 user manual — Table A-5. Telnet Session Options (1 of 2)
Page 85 · click to enlarge
Page 85

A. Configuration Options

Table A-5. Telnet Session Options (1 of 2)

Possible SettingsEnable, Disable Default Setting: Enable

Specifies if the unit will respond to a Telnet session request from a Telnet client on an interconnected IP network.

Enable – Allows Telnet sessions between the unit and a Telnet client.

Disable – No Telnet sessions allowed.

Possible SettingsEnable, Disable Default Setting: Disable

Used to secure access to the ATI through a Telnet session. Login IDs are created with a password and access level. Refer to Creating a Login in Chapter 7, Security.

Enable – Security is enabled. When access is attempted via Telnet, the user is prompted for a Login ID and password.

Disable – No Login required for a Telnet session.

Possible SettingsAdministrator , Operator Default Setting: Administrator

The Telnet session access level is interrelated with the access level of the Login ID. Refer to ATI Access Levels in Chapter 7, Security, for more information.

Administrator – This is the higher access level, permitting full control of the unit. Access level is determined by the Login ID. If Telnet Login Required is disabled, the session access level is Administrator.

Operator – This is the lower access level, permitting read-only access to status and configuration screens.

Possible SettingsEnable, Disable Default Setting: Disable

Provides automatic logoff of a Telnet session.

„ Inactivity Timeout is not available if the unit is in a DSLAM running in

IP Conservative mode; this option is forced to Enable.

Enable – The Telnet session terminates automatically after the Disconnect Time.

Disable – A Telnet session will not be closed due to inactivity.

8784-A2-GB20-30 February 2001 A-11

Show 4 more labels / short text on this page
Telnet Session · Telnet Login Required · Session Access Level · Inactivity Timeout
Page 86 of the Paradyne 8784 user manual — GENERAL SNMP MANAGEMENT OPTIONS
Page 86 · click to enlarge
Page 86

A. Configuration Options

Table A-5. Telnet Session Options (2 of 2)

Possible Settings1 – 60 Default Setting: 5

Number of minutes of inactivity before a Telnet session terminates automatically. Timeout is based on no keyboard activity.

„ Disconnect Time (minutes) appears when Inactivity Timeout is enabled. It does not

appear when the unit is connected to a DSLAM card running in IP Conservative mode.

1. 60 – The Telnet session is closed after the selected number of minutes.

General SNMP Management Options

To access the General SNMP Management Options screen, follow this menu selection sequence:

Main Menu→Configuration→Current Configuration→ Management and Communication→General SNMP Management

main/config/management/SNMP Hotwire Slot4 Model: 8784

GENERAL SNMP MANAGEMENT OPTIONS

SNMP ManagementEnable
Community Name 1Public Name 1 Access: Read/Write Community Name 2: Public Name 2 Access: Read/Write

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

A-12 February 2001 8784-A2-GB20-30

Disconnect Time (Minutes)

Page 87 of the Paradyne 8784 user manual — Table A-6. General SNMP Management Options
Page 87 · click to enlarge
Page 87

A. Configuration Options

Table A-6. General SNMP Management Options

Possible SettingsEnable, Disable Default Setting: Disable

Enable or disables the SNMP management features.

Enable – Enables SNMP management capabilities.

Disable – Disables SNMP management capabilities.

Possible SettingsASCII text field Default Text: Public

Identifies the name of the community allowed to access the unit’s MIB. The community name must be supplied by an external SNMP manager when that manager attempts to access an object in the MIB.

ASCII text field – Enter or edit a community name.

Clear – Clears the community name field.

Possible SettingsRead, Read/Write Default Setting: Read

Determines the access level for Community Name 1.

Read – Allows read-only access (get) for Community Name 1.

Read/Write – Allows read/write access (get) for Community Name 1.

Possible SettingsASCII text field Default Text: [null string]

Identifies the name of the second community allowed to access the unit’s MIB. The community name must be supplied by an external SNMP manager when that manager attempts to access an object in the MIB.

ASCII text field – Enter or edit a community name.

Clear – Clears the community name field.

Possible SettingsRead, Read/Write Default Setting: Read

Determines the access level for Community Name 2.

Read – Allows read-only access (get) for Community Name 2.

Read/Write – Allows read/write access (get/set) for Community Name 2.

8784-A2-GB20-30 February 2001 A-13

Show 5 more labels / short text on this page
SNMP Management · Community Name 1 · Name 1 Access · Community Name 2 · Name 2 Access
Page 88 of the Paradyne 8784 user manual — SNMP NMS SECURITY OPTIONS
Page 88 · click to enlarge
Page 88

A. Configuration Options

SNMP NMS Security Options

To access the SNMP NMS Security Options screen, follow this menu selection sequence:

Main Menu→Configuration→Current Configuration→ Management and Communication →SNMP NMS Security

main/config/management/security Hotwire Slot: 4 Model: 8784

SNMP NMS SECURITY OPTIONS

NMS IP ValidationEnable Number of Managers: 2

NMS 1 IP Address: 135.014.040.001 Clear Access Type: Read/Write NMS 2 IP Address: 135.014.003.027 Clear Access Type: Read/Write NMS 3 IP Address: 135.014.001.008 Clear Access Type: Read NMS 4 IP Address: 135.014.002.024 Clear Access Type: Read NMS 5 IP Address: 204.128.146.035 Clear Access Type: Read

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

A-14 February 2001 8784-A2-GB20-30

Page 89 of the Paradyne 8784 user manual — Table A-7. SNMP NMS Security Options
Page 89 · click to enlarge
Page 89

A. Configuration Options

Table A-7. SNMP NMS Security Options

Possible SettingsEnable, Disable Default Setting: Disable

Specifies whether security checking is performed on the IP address of SNMP management systems attempting to access the node.

Enable – Security checking is performed on the IP address of SNMP management systems attempting to access the node.

Disable – No security checking is performed.

Possible Settings1, 2, 3, 4, 5, 6, 7, 8, 9, 10 Default Setting: 1

Specifies the number of SNMP management systems that can send SNMP messages.

1. 5 – Number of trap managers. An NMS IP address is required for each manager.

NMS n IP Address

Possible Settings001.000.000.000 – 223.255.255.255, Clear Default Setting: 000.000.000.000

Specifies the Internet Protocol address used to identify each SNMP manager.

001.000.000.000 – 223.255.255.255 – Enter an address for each SNMP manager. The range for the first byte is 001 to 223, with the exception of 127. The range for the remaining three bytes is 000 to 255.

Clear – Clears the IP address and sets to all zeros.

Possible SettingsRead, Read/Write Default Setting: Read

Determines the access level allowed for an authorized NMS when IP address validation is being performed.

Read – Allows read-only access (get) to the accessible objects in the MIB for this device.

Read/Write – Allows read/write access (get/set) to the accessible objects in the MIB for this device.

8784-A2-GB20-30 February 2001 A-15

NMS IP Validation · Number of Managers · Access Level

Page 90 of the Paradyne 8784 user manual — SNMP TRAPS OPTIONS
Page 90 · click to enlarge
Page 90

A. Configuration Options

SNMP Trap Options

To access the SNMP Traps Options screen, follow this menu selection sequence:

Main Menu→Configuration→Current Configuration→ Management and Communication→SNMP Traps

main/config/management/trap Hotwire Slot4 Model: 8784

SNMP TRAPS OPTIONS

SNMP TrapsEnable Number of Trap Managers: 5

NMS 1 IP Address: 135.014.040.001 Clear NMS 2 IP Address: 135.014.003.027 Clear NMS 3 IP Address: 135.014.001.008 Clear NMS 4 IP Address: 135.014.002.024 Clear NMS 5 IP Address: 204.128.146.035 Clear

General TrapsBoth Enterprise Specific Traps: Disable Link Traps: Both Link Traps Interfaces: All

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

A-16 February 2001 8784-A2-GB20-30

Page 91 of the Paradyne 8784 user manual — Table A-8. SNMP Trap Options (1 of 2)
Page 91 · click to enlarge
Page 91

A. Configuration Options

Table A-8. SNMP Trap Options (1 of 2)

Possible SettingsEnable, Disable Default Setting: Disable

Controls the generation of SNMP trap messages.

Enable – SNMP trap messages are sent out to SNMP managers.

Disable – No SNMP trap messages are sent out.

Number of Trap Managers

Possible Settings1, 2, 3, 4, 5 Default Setting: 1

Sets the number of SNMP management systems that will receive SNMP traps.

„ This field is not available when the unit is running in IP Conservative mode.

1 to 5 – Number of trap managers. An NMS IP address is required for each manager.

NMS n IP Address

Possible Settings001.000.000.000 – 223.255.255.255, Clear Default Setting: 000.000.000.000

Specifies the Internet Protocol address used to identify each SNMP trap manager.

„ This field is not available when the unit is running in IP Conservative mode.

001.000.000.000 – 223.255.255.255 – Enter an address for each SNMP trap manager. The range for the first byte is 001 to 223, with the exception of 127. The range for the remaining three bytes is 000 to 255.

Clear – Clears the IP address and sets to all zeros.

Possible SettingsIMC , DSL1 , DSL2 Default Setting: IMC

Provides the network destination path of each trap manager.

„ NMS n Destination is only available when the unit is configured as an NTU and not

running in IP Conservative mode. Disabled ports cannot be specified.

IMC – The Internal Management Channel (IMC) is the default network destination. This is the management interface to the MCC card in the DSLAM.

DSL1 to DSL2 – The specified port is the network destination.

Possible SettingsDisable, Warm, AuthFail, Both Default Setting: Both

Determines which SNMP traps are sent to each trap manager.

Disable – No general trap messages are sent.

Warm – Sends trap message for warmStart events.

AuthFail – Sends trap message for authenticationFailure events.

Both – Sends both trap messages.

8784-A2-GB20-30 February 2001 A-17

SNMP Traps · NMS n Destination · General Traps

Page 92 of the Paradyne 8784 user manual — Table A-8. SNMP Trap Options (2 of 2)
Page 92 · click to enlarge
Page 92

A. Configuration Options

Table A-8. SNMP Trap Options (2 of 2)

Possible SettingsEnable, Disable Default Setting: Disable

Determines if SNMP traps are generated for enterprise-specific events.

Enable – SNMP traps are generated for enterpriseSpecific events.

Disable – No enterprise-specific event traps are sent.

Possible SettingsDisable, Up, Down, Both Default Setting: Both

Determines if SNMP traps are generated for link up and link down for one of the communication interfaces.

Disable – No linkUp or linkDown SNMP traps are generated.

Up – A linkUp trap is generated when the unit recognizes that one of the communication interfaces is operational.

Down – A linkDown trap is generated when the unit recognizes a failure in one of the communication interfaces.

Both – Sends trap messages for detection of both linkUp and linkDown.

Possible SettingsNetwork, DSX-1, All Default Setting: All

Determines if the SNMP linkUp, SNMP linkDown, and interface-related enterpriseSpecific traps are generated for the network DSL interface and/or DSX-1 interface (DTE).

Network – SNMP trap messages are generated for the DSL network interface.

DSX-1 – SNMP trap messages are generated for the DSX-1 interface.

All – SNMP trap messages are generated for the DSL network interface, COM port, and DSX-1 interface.

A-18 February 2001 8784-A2-GB20-30

Enterprise Specific Traps · Link Traps · Link Traps Interfaces

Page 93 of the Paradyne 8784 user manual — SNMP Trap Description Possible Cause
Page 93 · click to enlarge
Page 93

B

Standards Compliance for SNMP Traps

SNMP Traps

This section describes the unit's compliance with SNMP standards and any special operational features for the SNMP traps supported. The unit supports the following traps:

„ linkUp and linkDown

warmStart

SNMP Trap Description Possible Cause

warmStart The unit has reinitialized itself.

„ Reset command.

„ Power disruption.

The trap is sent after the unit resets and stabilizes.

There are no variable-bindings.

authenticationFailure

SNMP Trap Description Possible Cause

authenticationFailure Failed attempts to access the unit.

Three unsuccessful attempts were made to enter a correct login/password combination.

There are no variable-bindings.

8784-A2-GB20-30 February 2001 B-1

„ warmStart · „ authenticationFailure

Page 94 of the Paradyne 8784 user manual — linkUp/Down Variable-Bindings
Page 94 · click to enlarge
Page 94

B. Standards Compliance for SNMP Traps

linkUp and linkDown

The link SNMP traps are:

„ linkUp – The unit recognizes that one of the communication interfaces is operational.

„ linkDown – The unit recognizes that one of the communication interfaces is not operational.

The network and synchronous port interfaces (physical sublayer) are represented by an entry in the MIB-II interfaces table and supported by the DS1 MIB.

The following list describes the conditions that define linkUp and linkDown:

linkUp/Down Variable-Bindings

„ ifIndex (RFC 1573)

This object provides the index into the ifTable and potentially into tables in other MIBs. The values of ifIndex are the same for all models, although not all indexes are supported for each model. The ifIndex included with the trap consists of the slot number times 1000, plus:

– 2DSL Network Interface, Port 1 – 3DSL Network Interface, Port 2

– 10DSX-1 Port, Port 1 – 11DSX-1 Port, Port 2

„ ifAdminStatus (RFC 1573)

This object specifies the operational state of the interface: – up(1)

DSL Network: DSL link is established. Synchronous Data Port: Port is enabled and both CTS and DSR are ON.

DSL Network: DSL link is not established. Synchronous Data Port: Port is disabled or CTS or DSR is OFF. – testing(3)

A test is active on the interface.

„ ifOperStatus (RFC 1573)

This object contains the same value as ifAdminStatus.

„ ifType (RFC 1573)

This object is the type of interface: – propPointToPointSerial(22)

Used for the synchronous data ports and EOC. – DS1(18)

Used for DSX-1 T1 interface – HDSL(96)

Used for the HDSL network interface.

B-2 February 2001 8784-A2-GB20-30

– down(2)

Page 95 of the Paradyne 8784 user manual — SNMP Trap Description Possible Cause
Page 95 · click to enlarge
Page 95

B. Standards Compliance for SNMP Traps

Enterprise-Specific Traps

The enterpriseSpecific trap indicates that an enterprise-specific event has occurred. The Specific-trap field identifies the particular trap that occurred. The following table lists the enterprise-specific traps supported by the unit:

SNMP Trap Description Possible Cause

enterpriseSelfTestFail(2) A hardware failure of the unit is detected during the unit's self-test. The trap is generated after the unit completes initialization.

Failure of one or more of the unit's hardware components.

enterpriseDeviceFail(3) An internal device failure. Operating software has detected an internal device failure.

enterpriseTestStart(5) A test is running. At least one test has been started on an interface.

enterpriseConfigChange(6) The configuration changed via the user interface. The trap is sent after 60 seconds have elapsed without another change. This suppresses the sending of numerous traps when multiple changes are made in a short period of time, as is typically the case when changing configuration options.

Configuration has been changed via the ATI.

enterpriseTestStop(105) All tests have been halted. All tests have been halted on an interface.

There are no variable-bindings for enterpriseDeviceFail and enterpriseConfigChange. The variable-binding for enterpriseSelfTestFail is devSelfTestResults.

8784-A2-GB20-30 February 2001 B-3

Page 96 of the Paradyne 8784 user manual — enterpriseTestStart/Stop Variable-Bindings Possible Cause
Page 96 · click to enlarge
Page 96

B. Standards Compliance for SNMP Traps

The tests that affect the enterpriseTestStart, enterpriseTestStop, and the variable-bindings are different for each particular interface. Diagnostic tests are only supported on the physical T1 network and user data port interfaces. The specific tests and variable-bindings are described in the following table:

enterpriseTestStart/Stop Variable-Bindings Possible Cause

Interface

DSL Network „ ifIndex (RFC 1573)

„ enterpriseTest Start – Any

one of the following tests is active on the interface:

„ ifAdminStatus (RFC 1573)

„ ifOperStatus (RFC 1573)

– Line Loopback – Repeater Loopback

„ ifType (RFC 1573)

– Remote Line Loopback – Send and Monitor 511

„ ifTestType (RFC 1573)

The following objects control tests in SNMP-managed devices:

„ enterpriseTest Stop – No

– noTest – Stops the test in

tests currently running on the interface.

progress.

– testLoopLLB – Initiates a Local

Loopback.

– testLoopRLB – Initiates a

Remote Loopback.

– testSendMon511 – Initiates a

Send and Monitor 511 test.

– testSendLLBUp – Initiates an

LLB Up message to the remote unit.

– testSendLLBDown – Initiates

an LLB Down message to the remote unit.

DSX-1 „ ifIndex (RFC 1573)

„ enterpriseTest Start – Any

one of the following tests is active on the interface: – Data Terminal

„ ifAdminStatus (RFC 1573)

„ ifOperStatus (RFC 1573)

Loopback – Repeater Loopback

„ ifTestType (RFC 1573)

The following objects control tests in SNMP-managed devices:

– testLoop RLB – initiates

– noTest – Stops the test in

progress.

– testLoop DTLB –

initiates a DSX-1 DTE Loopback

„ enterpriseTest Stop – No

tests currently running on the interface.

B-4 February 2001 8784-A2-GB20-30

a Repeater Loopback · – testLoopExternalDTE

Page 97 of the Paradyne 8784 user manual — 50-Pin Connector Pinout Function
Page 97 · click to enlarge
Page 97

Connector Pin Assignments

Overview

This section lists the pin assignments for the front panel 50-pin DTE connector. For information about the DSLAM connectors, see the appropriate DSLAM installation document.

Front Panel 50-pin DTE Connector Pinouts

DTE connectors on the Hotwire 8784 Termination Unit provide the 4-wire DSX-1 interface from each DSL port to the DTE. The following table lists the pin assignments for each of these interfaces.

50-Pin Connector Pinout Function

DSX-1 Port

30 Data Out (Ring)

5 Data Out (Tip)

29 Data In (Tip)

4 Data In (Ring)

27 Data Out (Ring)

2 Data Out (Tip)

26 Data In (Tip)

1 Data In (Ring)

8784-A2-GB20-30 February 2001 C-1

Show 7 more labels / short text on this page
· · · · · Port 2 · Port 1
Page 98 of the Paradyne 8784 user manual — Connector Pin Assignments
Page 98 · click to enlarge
Page 98

C. Connector Pin Assignments

C-2 February 2001 8784-A2-GB20-30

Page 99 of the Paradyne 8784 user manual — Specifications Criteria*
Page 99 · click to enlarge
Page 99

D

Technical Specifications

Specifications Criteria*

Size Length10 inches (25.4 cm)
Height12.3 inches (31.1 cm)
Width0.8 inch (2.0 cm)

Weight Approximately 1.3 lbs. (0.6 kg)

Safety Certifications Refer to the equipment's label for approvals on product.

Power The Hotwire 8784 TDM SDSL Termination Unit contains a DC-to-DC converter that requires –48V power input. The –48V power is distributed through the Hotwire DSLAM backplane.

Maximum Power Dissipation19 watts Result: 64.83 Btu/hr

32° to 122° F (0° to 50° C)

–4° F (–20° C) to 158° F (70° C)

5% to 85% (noncondensing)

Withstands normal shipping and handling.

* Technical specifications are subject to change without notice.

8784-A2-GB20-30 February 2001 D-1

Show 6 more labels / short text on this page
Approvals · Physical Environment · Operating temperature · Storage temperature · Relative humidity · Shock and vibration
Page 100 of the Paradyne 8784 user manual — Technical Specifications
Page 100 · click to enlarge
Page 100

D. Technical Specifications

D-2 February 2001 8784-A2-GB20-30

Page 101 of the Paradyne 8784 user manual — Glossary
Page 101 · click to enlarge
Page 101

Glossary

511 A random bit test 511 bytes in length.

AIS Alarm Indication Signal. A signal transmitted downstream instead of the normal signal to preserve transmission continuity and to indicate to the rest of the network that a fault exists. Also called a Blue Alarm.

AMI Alternate Mark Inversion. A line coding technique used to accommodate the ones density requirements of E1 or T1 lines.

ATI Asynchronous Terminal Interface. A menu-driven, VT100-compatible system for configuring and managing the termination unit.

BPV Bipolar Violation. In a bipolar signal, a one (mark, pulse) which has the same polarity as its predecessor.

bridged tap Any part of the local loop that is not in the direct talking path between the CO and the service user.

CAP Carrierless Amplitude and Phase Modulation. A transmission technology for implementing a DSL. Transmit and receive signals are modulated into two wide-frequency bands using passband modulation techniques.

CD Carrier Detect. The received line signal detector. V.24 circuit 109.

CO Central Office/Central Site. The PSTN facility that houses one or more switches serving local telephone subscribers.

COM port Communications port. A computer's serial communications port used to transmit to and receive data from a modem. The modem connects directly to this port.

CP Customer Premises.

CPE Customer Premises Equipment. Terminal equipment on the service user's side of the telecommunications network interface.

CPU Central Processing Unit. The main or only computing device in a data processing system.

CRC Cyclic Redundancy Check. A mathematical method of confirming the integrity of received digital data.

CTS Clear To Send. A signal indicating that the device is ready for the DTE to transmit data. Usually occurs in response to Request To Send (RTS).

CV Code Violation. Detected when using HDB3 coding format, this is equivalent to a BPV when using AMI coding.

DCE Data Communications Equipment. The equipment that provides the functions required to establish, maintain, and end a connection. It also provides the signal conversion required for communication between the DTE and the network.

DCLB Data Channel LoopBack. Loops the data received from the network interface, for all DS0 channels allocated to the selected port, back to the network.

DSL Digital Subscriber Line. The non-loaded, local-loop copper connection between the customer and the first node within the network.

DSLAM Digital Subscriber Line Access Multiplexer. A platform for DSL modems that provides high-speed data transmission over traditional twisted-pair wiring.

8784-A2-GB20-30 February 2001 GL-1

Page 102 of the Paradyne 8784 user manual — Glossary
Page 102 · click to enlarge
Page 102

DSR Data Set Ready. A signal from the modem to the DTE that indicates the modem is turned ON and connected to the DTE.

DSX-1 Digital Signal Cross Connect level 1. An interconnection point for terminals, multiplexers and transmission facilities.

DTE Data Terminal Equipment. The equipment, such as a computer or terminal, that provides data in the form of digital signals for transmission.

DTLB Data Terminal LoopBack. Loopback mode that loops the data for a particular synchronous data port back to the port just before it is combined with the rest of the T1 data stream.

DTR Data Terminal Ready. A signal from the DTE to the modem, sent via Pin 20 of the EIA-232 interface (V.24 circuit 108/1, /2), that indicates the DTE is turned ON and connected to the modem.

E1 A wideband digital interface operating at 2.048 Mbps, defined by ITU recommendations G.703 and G.704. It is used primarily outside North America.

EER Excessive Error Rate. An error rate that is greater than the threshold that has been configured in the device.

EIA-530-A An Electronic Industries Association standard for a high-speed, 25-position, DCE/DTE interface.

EOC Embedded Operations Channel. An in-band channel between DSL devices, used for 8 kbps management data.

ES Errored Seconds. A second with one or more error events (one or more CRC error events or OOFs).

ESF Extended SuperFrame. The T1 transmission standard that specifies 24 frames as an extended superframe to be used for frame synchronization and to locate signaling bits.

Ethernet A type of network that supports high-speed communication among systems. It is a widely implemented standard for LANs. All hosts are connected to a coaxial cable where they contend for network access using a Carrier Sense, Multiple Access with Collision Detection (CSMA/CD) paradigm.

ETSI European Telecommunications Standardization Institute. An organization that produces technical standards in the area of telecommunications.

factory defaults A predetermined set of configuration options containing the optimum settings for operation on asynchronous dial networks.

FAS Frame Alignment Signal. A loss of frame (LOF) error detection.

FAW Frame Alignment Word. A loss of synchronization error detection.

FCC Federal Communications Commission. The Board of Commissioners that regulates all electrical communications that originate in the United States.

FDL Facility Data Link. The selected framing bits in the ESF format used in a wide-area link that are used for control, monitoring, and testing.

FEBE Far-End Block Error. Block errors reported by remote equipment.

frame One identifiable group of data bits that includes a sequence of bits for control and identification information.

framer A program or device that assembles and disassembles frames.

frame relay A high-speed connection-oriented packet switching WAN protocol using variable-length frames.

GL-2 February 2001 8784-A2-GB20-30

Glossary

Page 103 of the Paradyne 8784 user manual — Glossary
Page 103 · click to enlarge
Page 103

FTP File Transfer Protocol. A TCP/IP standard protocol that allows a user on one host to access and transfer files to and from another host over a network, provided that the client supplies a login identifier and password to the server.

G.703 An ITU recommendation for the physical and logical characteristics of hierarchical digital devices.

G.704 An ITU recommendation for synchronous frame structures.

HDB3 High Density Bipolar Three Zeros Substitution. A line coding technique used to accommodate the ones density requirements of E1 lines.

HDSL High-bit-rate Digital Subscriber Line. A technique for high bandwidth, bidirectional transmission over copper wire for T1 and E1 services.

IP Internet Protocol. An open networking protocol used for internet packet delivery.

IP address Internet Protocol address. The address assigned to an internet host.

LAN Local Area Network. A privately owned and administered data communications network limited to a small geographic area.

LED Light Emitting Diode. A light or status indicator that glows in response to the presence of a certain condition (e.g., an alarm).

LIU Line Interface Unit. A physical layer data transmitter and receiver.

LLB Line LoopBack. A test in which the received signal on the network interface is looped back to the network without change.

loopback A diagnostic procedure that sends a test message back to its origination point.Used to test various portions of a data link in order to isolate an equipment or data line problem.

LOS Loss of Signal. The line condition where there are no pulses.

LTU Line Termination Unit. The control unit on the network end of a link. (The NTU is on the customer premises end.)

MCC Management Communications Controller. The DSLAM circuit card used to configure and monitor the DSLAM.

MIB Management Information Base. A database of managed objects used by SNMP to provide network management information and device control.

MIB II MIB Release 2. The current Internet-standard MIB, defined by RFC 1213.

MTSO Mobile Telephone Switching Office. A generic name for the main cellular switching center which supports multiple base stations.

NMS Network Management System. A computer system used for monitoring and controlling network devices.

NTU Network Termination Unit. The unit on the customer premises end of a link. (The LTU is on the network end.)

OOF Out Of Frame. An error condition in which frame synchronization bits are in error.

PPP Point-to-Point Protocol. A protocol for packet transmission over serial links, specified by Internet RFC 1661.

receiver A circuit that accepts data signals from a transmitter.

reset A reinitialization of the device that occurs at power-up or in response to a reset command.

RLB Repeater LoopBack. Loops the signal being sent to the network back to the DTE Drop/Insert and data ports after it has passed through the framing circuitry of the device.

8784-A2-GB20-30 February 2001 GL-3

Glossary

Page 104 of the Paradyne 8784 user manual — Glossary
Page 104 · click to enlarge
Page 104

router A device that connects LANs by dynamically routing data according to destination and available routes.

RS-449 An Electronic Industries Association's standard for a general-purpose, 37-position, DCE/DTE interface.

RTS Request to Send. A signal from the DTE to the device, indicating that the DTE has data to send. V.24 circuit 105.

RXD Received Data. Pin 3 of the EIA-232 interface that is used by the DTE to receive data from the modem. Conversely, the modem uses Pin 3 to transmit data to the DTE.

SDSL Symmetric Digital Subscriber Line. A technique for the use of an existing twisted-pair line that permits high bandwidth, bidirectional transmission.

SES Severely Errored Seconds. Usually defined as a second during which a specific number of CRC errors was exceeded, or an OOF or other critical error occurred.

SNMP Simple Network Management Protocol. Protocol for open networking management.

T1 A term for a digital carrier facility used to transmit a DS1 formatted digital signal at 1.544 Mbps. It is used primarily in North America.

TCP/IP Transmission Control Protocol/Internet Protocol. The dominant protocol suite in the worldwide Internet, TCP allows a process on one machine to send data to a process on another machine using the IP. TCP can be used as a full-duplex or one-way simplex connection.

TDM Time Division Multiplexer. A device that enables the simultaneous transmission of multiple independent data streams into a single high-speed data stream by simultaneously sampling the independent data streams and combining these samples to form the high-speed stream.

Telnet Virtual terminal protocol in the Internet suite of protocols. Allows the user of one host computer to log into a remote host computer and interact as a normal terminal user for that host.

TFTP Trivial File Transfer Protocol. A standard TCP/IP protocol that allows simple file transfer to and from a remote system without directory or file listing. TFTP is used where FTP is not available.

transceiver A circuit capable of acting as both a transmitter and a receiver.

transmitter A circuit capable of generating, modulating, and sending a signal for communication, control, and other purposes.

TXD Transmit Data. Pin 2 of the EIA-232 interface that is used by the DTE to transmit data to the modem. Conversely, the modem uses Pin 2 to receive data from the DTE.

UNIX An operating system developed at AT&T Bell Laboratories and since used as the basis of similar operating systems.

V.35 An ITU-T standard for a high-speed, 34-position, DCE/DTE interface.

WAN Wide Area Network. A network that spans a large geographic area.

X.21 An ITU-T standard for a high-speed, 15-position, DCE/DTE interface.

Yellow Alarm An outgoing signal transmitted when a DS1 or DS3 terminal has determined that it has lost the incoming signal.

GL-4 February 2001 8784-A2-GB20-30

Glossary

Page 106 of the Paradyne 8784 user manual — E
Page 106 · click to enlarge
Page 106

D

F

deleting a Login ID, 7-3 Destination, SNMP traps, A-17 Device

factory defaults, 3-3–3-4 Failure, self-test result, 4-5 features, 1-2 Framing, A-5 function keys, 2-7

and test monitoring, 1-2 Failed

self-test result, 4-5 status message, 4-3 messages, 6-3 Name, 3-2 Tests, 5-8 diagnostics, 1-2 dimensions, D-1 Disconnect Time, for Telnet session, A-12 Display LEDs, 4-13 documents, related, vi DOS TFTP server on, 3-6 Download Failed, status message, 4-3 downloading a configuration, 3-6 DSL

and message area, 2-5

G

assigning access, 7-4 Options, A-12 Traps sent, A-17

H

Health and Status messages, 4-3

Failed, self-test result, 4-5 Line Rate, A-3 Mode, A-9 Port LEDs, 4-14 DSLAM

Identity, 3-2 IMC, defined, 1-2 Inactivity Timeout, Telnet session, A-11 intended audience, v IP address

exiting from session, 2-9 login, 2-2 management serial port, 1-2 DSX-1

DSL peer, A-3 example, 8-2 NMS, A-15, A-17 selecting, 8-1 SNMP manager, 7-4 IP Conservative, IP addressing depends upon, 8-1 IP Validation, NMS security, A-15

Failed self-test results, 4-5 Interface Options, A-4 LEDs, 4-14 Performance Statistics, 4-11 Send All Ones on Failure, A-6 DTE

K

connector pin assignments, C-1 Loopback, 5-5

function, 2-7 keyboard, 2-6

E

EER (Excessive Error Rate) status message, 4-3 effective access level, 7-1 Embedded Operations Channel (EOC), 1-2 ending

active, test status, 4-5 LEDs, 4-13

an ATI session, 2-9 tests, 5-9 Enterprise Specific Traps, A-18, B-3 environment requirements, D-1 Equalization, Line, A-5 Error

Display, 4-13 lamp test, 5-8 viewing via the ATI, 4-13 Line

Coding format, A-5 Equalization, A-5 Framing, A-5 Loopback (LLB), 5-3 Remote Telco Loopback, enabling/disabling, A-9

messages (line 24), 6-3 Rate Threshold, A-5 Statistics, 4-6 Excessive Error Rate (EER) Threshold, A-2, A-5

IN-2 February 2001 8784-A2-GB20-30

Show 5 more labels / short text on this page
Index · General · SNMP Management · keys · lamp test, 5-8
Page 107 of the Paradyne 8784 user manual — M
Page 107 · click to enlarge
Page 107

N

Trap Interfaces, A-18 Traps, A-18 Up LEDs, 4-14 link-layer protocols, 8-1 linkUp and linkDown traps, B-2 local

navigating the screens, 2-6 Net

Com Link Down, status message, 4-4 Margin Threshold, status message, 4-4 Network

current performance statistics, 4-10 DSL Failed, self-test result, 4-5 enabling/disabling AutoRate, 3-10 Error Statistics, 4-6 Interface Options, A-2 performance statistics, 4-8 sample configurations, 1-3 Send AIS on Failure, A-6 tests, 5-2 NMS

Line Loopback (LLB), 5-3 management features, 1-2 LOF (Loss Of Frame) status message, 4-3 login

DSLAM, 2-2 Telnet requirement, A-11 Login ID, 7-1

access levels, 7-1 adding, 7-2 ASCII, printable characters, 7-3 deleting, 7-3 Loopback

Destination, A-17 IP Address, A-15 IP Validation, A-15 SNMP

DTE, 5-5 Line, 5-3 Remote Send Line, 5-6 Remote Telco Line , enabling/disabling, A-9 Repeater, 5-4 Telco-initiated, A-9 LOS (Loss Of Signal), status message, 4-3 LTU

connectivity, 8-1 Security Options, A-14 No Test Active, status message, 4-5 NTU

DSL Mode, A-9 Mismatch, status message, 4-4 Number of

DSL Mode, A-9 Mismatch, status message, 4-4

NMS Managers, A-15 Trap Managers, A-17

M

O

main menu, 2-3 Management

OK LED, 4-14 OOF (Out Of Frame), status message, 4-4 Operator

and Communication Options, A-10 basic MIBs, 1-4 enabling/disabling SNMP, A-13 General SNMP Options, A-12 port settings, 2-1 SNMP, 1-4 Margin Threshold, A-2 MCC

ATI access level, 7-1 Telnet Access Level, A-11 options

configuration tables, A-1 overview

features, 1-1 user’s guide, v

defined, 1-2 IP addressing scheme, 8-1 logging in, 2-2 Memory Fail, self-test result, 4-5 messages

alarm and device, 6-1, 6-3 health and status, 4-3 line 24, 6-3 self-test results, 4-5 test status, 4-5 MIB support, 1-4 Monitor and Send 511 pattern, 5-7 monitoring the unit, 4-1

8784-A2-GB20-30 February 2001 IN-3

Index · Link

Page 108 of the Paradyne 8784 user manual — S
Page 108 · click to enlarge
Page 108

P

Session Access Level, Telnet, A-11 size of card, D-1 SNMP

Passed, self-test result, 4-5 pattern test, 5-7 Peer IP Address, A-3 performance statistics

Community Name Access, A-13 General Management Options, A-12 Management

Current Network Performance, 4-10 DSX-1 Performance Statistics, 4-11 Error Statistics, 4-6 Network Performance Statistics, 4-8 physical environment requirements, D-1 pin assignments, C-1 Port Status, A-5 power requirements, D-1 Primary Clock Source, A-6

enabling/disabling, A-13 general, 1-4 limiting access, 7-4 NMS

Security, 7-4 Security Options, A-14–A-15 standards compliance for traps, B-1 system entries, 3-2 Traps, B-1

configuring, 6-2 enabling/disabling, A-17 Options, A-16 support, 1-4 specifications, D-1 standards compliance for SNMP traps, B-1 starting an ATI session, 2-2 start-up, 2-1 status

R

Auto, A-3 DSL Line, A-3 excessive errors threshold, A-5 related documents, vi Remote

management features, 1-2 Send Line Loopback, 5-6 Telco Line Loopback, enabling/disabling, A-9 Repeater Loopback (RLB), 5-4 Resetting, 3-11 resetting

Port, DSX-1, A-5 test messages, 4-5 Status menu

Display LEDs, 4-13 Performance Statistics

the AutoRate feature, 3-11 the unit from the Control menu, 3-12 restoring access to the ATI, 3-4, 3-11

Current Network, 4-10 DSX-1, 4-11 Network, 4-8 Network Error, 4-6 System and Test

S

Self-Test Results, 4-5 Status, 4-2 Test Status, 4-5 System

safety certifications, D-1 saving configuration options, 3-7 screen area, 2-5 security, 7-1

device name field, 3-2 Identity information, 3-2 LEDs, 4-14 Options, A-8 System Options

options, A-14 self-test results, 4-5 Send

AIS on Network Failure, A-6 All Ones on DSX-1 Failure, A-6 and Monitor 511, 5-7 Remote Line Loopback, 5-6

IN-4 February 2001 8784-A2-GB20-30

Index · Rate · Test Timeout, A-9

Page 109 of the Paradyne 8784 user manual — W
Page 109 · click to enlarge
Page 109

T

Telnet session inactivity, A-11 Test, A-9 Traps

technical specifications, D-1 Telco

configuring, 6-2 enabling/disabling, A-17 Enterprise Specific, A-18, B-3 general traps sent, A-17 Link, A-18 Link Interfaces, A-18 linkUp and linkDown, B-2 Number of Managers, A-17 SNMP, 1-4, B-1 SNMP Options, A-16 standards compliance, B-1 troubleshooting, 6-5

Line Loopback, 5-10 Loopback, enabling/disabling, A-9 Payload Loopback, 5-10 Remote Line Loopback, 5-11 Remote Line Loopback, enabling/disabling, A-9 Telnet

Login Required, A-11 Session

access requirement, 7-1 enabling/disabling, A-11 Options, A-10 terminal port, direct connection, 2-1 test

configuring SNMP traps, 6-2 Current Network Performance Statistics, 4-10 DSX-1 Performance Statistics, 4-11 Network Error Statistics, 4-6 Network Performance Statistics, 4-8

Abort All, 5-1 aborting, 5-9 accessing menu, 5-1 active statuses, 4-5 Device Tests, 5-8 DTE Loopback, 5-5 ending a, 5-9 lamp, 5-8 LED, 4-14 Line Loopback, 5-3 menu, 5-1 pattern, 5-7 procedures, 5-1 Remote Send Line Loopback, 5-6 Repeater Loopback, 5-4 Send and Monitor 511, 5-7 status messages, 4-5 stopping a, 5-9 Telco-initiated, 5-10 Test Duration, A-9 Test Timeout, 5-9, A-9 Threshold

U

UNIX, TFTP server on, 3-6 uploading a configuration, 3-6 user interface

asynchronous terminal, 2-1 how to access, 2-1 restoring access, 3-11–3-12

virtual function keys, 2-7

W

warmStart, B-1 weight, D-1

Excessive Error Rate, A-2, A-5 Margin, A-2

8784-A2-GB20-30 February 2001 IN-5

Index · timeout · initiated

Page 110 of the Paradyne 8784 user manual — Index
Page 110 · click to enlarge
Page 110

IN-6 February 2001 8784-A2-GB20-30

Index

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Alarm LED is on.A system failure has occurred.Refer to Table 4-1, Health and Status Messages, in Chapter 4, Monitoring the Unit, for the recommended action. p.67
Cannot access the unit via the ATI.The terminal is not set up for the correct rate or data format, or the unit is configured so it prevents access.„ Check the cable and connections. „ Ensure that the unit is configured properly in the DSLAM. Verify its IP address. „ Reset the unit. p.67
Device Fail appears on the System and Test Status screen under Self-Test results.The unit detects an internal hardware failure.„ Reset the unit. „ Contact your service representative. p.67
No power, or the LEDs are not lit.The unit is not properly seated in the DSLAM.Verify that the unit is properly inserted. p.67
No power, or the LEDs are not lit.There is no power to the DSLAM.Verify that the DSLAM has power. p.67
An LED is not lit.LED is out.Run the Lamp Test. If the LED in question does not flash with the other LEDs, then contact your service representative. p.67
Not receiving data.The network or DSX-1 port cables are not connected (check front panel LEDs for more information).„ Check network and DSX-1 port cables. „ Check Health and Status menu. „ Run Loopback tests. Refer to Chapter 5, Testing. p.67
Not receiving data.A test is being executed on the unit (check the TEST LED on the front panel).Stop the test or wait for the test to end. p.67
Not receiving data.The far-end device is offline.Make sure the far-end device is on. p.67
Power-On Self-Test fails. Only Alarm LED is on after power-on.The unit has detected an internal hardware failure.„ Reset the unit and try again. „ Contact your service representative. p.67

Ask about the Paradyne 8784

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.