USER’S GUIDE
October 1997

Copyright 1997 Paradyne Corporation. All rights reserved. Printed in U.S.A.
This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Avenue North, P.O. Box 2826, Largo, Florida 33779-2826.
Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.
Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual.
All products and services mentioned herein are the trademarks, service marks, registered trademarks or registered service marks of their respective owners.
Contact your sales or service representative directly for any help needed. For additional information concerning warranty, service, repair, spare parts, installation, documentation, or training, use one of the following methods:
Via Telephone: Call our automated call system to receive current information via fax or to speak with a
company representative.
— Within the U.S.A., call 1-800-870-2221 — International, call 727-530-2340
Printed on recycled paper
A 7924-A2-GB20-30 October 1997

— Never install telephone wiring during a lightning storm.
— Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
— Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the
network interface.
— Use caution when installing or modifying telephone lines.
— Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of
electric shock from lightning.
— Do not use the telephone to report a gas leak in the vicinity of the leak.
B 7924-A2-GB20-30 October 1997

! WARNING:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation.
To Users of Digital Apparatus in Canada:
This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du règlement sur le matérial brouilleur du Canada.
C 7924-A2-GB20-30 October 1997


Document Purpose and Intended Audience
This guide contains information needed to set up, configure, and operate HotWire Model 7924-A1 T1 HDSL termination units. It is designed for central office technicians or network engineers who have an understanding of the deployment of digital subscriber line systems in a telephone company or private network environment.
HotWire 7924 may be ordered either as a standalone unit (7924-A1-xxx) or as a nest-mounted card (7924-B1-xxx) that fits in a HotWire 7900 nest. This guide describes the installation and maintenance procedures for the standalone version, Model 7924-A1-xxx.
Chapter 1 About HotWire Model 7924 Termination Units. Describes the features of each version of the Model 7924, and typical configurations.
Chapter 2 Installing the Unit. Describes how to install the unit and make connections.
Chapter 3 Using Terminal and Switchpack Modes. Provides instructions for connecting a VT100-compatible terminal user interface. Also describes how to make manual configuration changes directly on the board hardware.
Chapter 4 Customizing DSX-1-Compatible Units. Provides instructions for modifying configuration options by using the terminal interface or DIP switches and jumpers on the board.
Chapter 5 Customizing V.35-Compatible Units. Provides instructions for modifying configuration options by using the terminal interface or DIP switches and jumpers on the board.
v 7924-A2-GB20-30 October 1997

Chapter 6 Monitoring the Unit. Describes how to monitor unit status, LEDs, and network statistics. Also describes how to monitor the status of the unit on the opposite side of the HDSL connection.
Chapter 7 Testing. Provides information about available loopback tests.
Appendix A Worksheets. Contains all the configuration options, default settings, and possible settings to use for planning.
Appendix B Cable Pin Assignments. Contains connector and interface details.
Appendix C Switchpacks and Jumpers. Defines the switchpack and jumper positions on the board hardware. Includes board layout diagrams.
Glossary Defines acronyms and terms used in this document.
Index Lists key terms, acronyms, concepts, and sections in alphabetical order.
7900-A2-GB20 HotWire Model 7900 Basic Maintenance Processor User’s Guide
7900-A2-GB21 HotWire Model 7900 SNMP Maintenance Processor User’s Guide
7900-A2-GN10 HotWire Model 7900 10-Slot Standalone Shelf Installation Instructions
7900-A2-GN20 HotWire Model 7900 Nest and Options Installation Guide
7920-A2-GB20 HotWire Models 7924 and 7925 T1 and E1 HDSL Nest Card Termination Units User’s Guide
7925-A2-GB20 HotWire Model 7925 Standalone E1 HDSL Termination Unit User’s Guide
To order additional product documentation, refer to Warranty, Sales, and Service Information on page A at the beginning of this User’s Guide.
vi 7924-A2-GB20-30 October 1997
About This Guide

HotWire 7924-A1 Models and Features
Products in the HotWire 7924 family provide “last mile/last kilometer” transport of T1-compatible circuits between customer facilities and central site equipment over 2- or 4-wire copper lines. The units can be used over distances substantially exceeding traditional T1 spans and Canadian Standards Association (CSA) loop standards.
HotWire 7924 standard features include:
V.35 or DSX-1 interface
Full support for T1 using two twisted-copper pairs
Full support for fractional T1 using one or two twisted-copper pairs
Automatic detection and compensation for inverted pairs and swapped loops, which simplifies installation
Tolerance of bridged taps
Local and remote alarm surveillance
Local and remote T1 network and HDSL loop performance monitoring
HotWire 7924 may be ordered either as a standalone unit (7924-A1-xxx) or as a nest-mounted card (7924-B1-xxx) that fits in a HotWire 7900 nest. This guide describes the installation and maintenance procedures for the standalone version, Model 7924-A1-xxx.
Up to ten standalone units may be installed in an optional HotWire 7900 10-Slot Standalone Shelf. This is a convenient way to stack standalone units, using a single power source.
To order additional product documentation, refer to Warranty, Sales, and Service Information on page A at the beginning of this User’s Guide.

About HotWire Model 7924 Termination Units
There are several versions of the Model 7924-A1, each supporting a different interface (DSX-1 or V.35) and power supply (120 Vac, 230 Vac, or –48 Vdc):
7924-A1-201 1.544 Mb/s DSX-1 compatible. Connection to 120 Vac power supply.
7924-A1-202 1.544 Mb/s V.35 compatible. Connection to 120 Vac power supply.
7924-A1-301 1.544 Mb/s DSX-1 compatible. Connection to 230 Vac power supply.
7924-A1-302 1.544 Mb/s V.35 compatible. Connection to 230 Vac power supply.
7924-A1-501 1.544 Mb/s DSX-1 compatible. Direct connection to –48 Vdc power supply. For use in a HotWire 7900 10-Slot Standalone Shelf only.
7924-A1-502 1.544 Mb/s V.35 compatible. Direct connection to –48 Vdc power supply. For use in a HotWire 7900 10-Slot Standalone Shelf only.

About HotWire Model 7924 Termination Units
HotWire Model 7924 standalone units can be used in campus applications where long loop distances normally require the campus to contract with the local telephone exchange carrier to deliver private line services across the campus.
Figure 1-1 shows two typical campus applications where remote PBXs or multiplexers are interconnected across a campus using two HotWire Model 7924 standalone units. In each pair, one unit is configured as a central site or central office (CO) unit and the other is the remote or customer premises (CP) unit.
The HotWire Model 7924 standalone unit is configured at the factory to operate at the CP side of a T1 HDSL connection. (Conversely, HotWire Model 7924 nest cards are configured for CO operation.) The central site unit must be reconfigured for CO operation in these configurations.

Customer Premises Central Site

Customer Premises Central Site
97-15295 · 97-15296

About HotWire Model 7924 Termination Units
HotWire Model 7924 standalone units are also ideal for delivering T1 services from a central site to the customer premises over long loop distances without repeaters.
Figure 1-2 shows a central-site application with a HotWire 7900 Nest containing HotWire Model 7924 nest cards. The nest cards at the central site each terminate a single HDSL subscriber line. Each line is then converted to a DSX-1 interface for connection to other central office equipment, such as a digital cross-connect system (DCS).

Customer Premises · 97-15294

About HotWire Model 7924 Termination Units
Cellular network providers must lease large numbers of T1 circuits in order to connect remote cell sites to mobile telephone switching offices (MTSOs). HotWire Model 7924 products provide an alternative to standard repeatered T1 services. Figure 1-3 depicts a typical cellular network access application.
Mobile Telephone Switching Office (MTSO)

User Interface Types
There are three types of user interfaces to the standalone units:
VT100-compatible terminal interface (see Chapter 3)
Manual setting of switches and jumpers (see Chapter 3)
Front Panel LED status indicators (see Chapter 6)
Cell Site · Customer Premises · 97-15297

Overview
This chapter describes the procedure for installing a single standalone termination unit using a 120 Vac or 230 Vac power supply (Model 7924-A1-20x or 7924-A1-30x).
If you have multiple standalone units at the same location, you may want to consider installing the units in a HotWire Model 7900 10-Slot Standalone Shelf. The Standalone Shelf is a convenient method for housing up to ten standalone termination units and uses only a single power source.
HotWire Model 7924-A1-50x units (which use –48 Vdc direct power) must be installed in a HotWire 7900 10-Slot Standalone Shelf. Installation instructions for these models are not provided in this User’s Guide.
To obtain information on the Standalone Shelf, refer to Product-Related Documents on page vi.
Verify that your package contains the following:
HotWire Model 7924-A1 unit
VT100 Terminal Cable
14′ twisted-pair network cable
Power cord with power transformer (optional)
Warranty card

Do not use a flat VF network cable, as this may severely degrade the performance of the termination unit. Use only a twisted-pair network cable.
HotWire 7924 V.35-compatible units are not designed to be used at both ends of an HDSL connection.
DSX-1-Compatible HotWire 7924 – Rear Panel
HDSL
48 VDC
V.35-Compatible HotWire 7924 – Rear Panel
Plug the power transformer into the appropriate (115 or 230 Vac) power outlet. Connect the power lead into the –48 Vdc jack on the rear panel.
To obtain information on the power supplies and power cord adapters available, refer to Warranty, Sales, and Service Information on page A at the beginning of this User’s Guide.
Installing the Unit · 97-15356-01 · 97-15264

Choosing an Interface Mode
You can make configuration changes either through an asynchronous terminal (Terminal Mode) or by manually changing switches and jumpers on the board (Switchpack Mode). Terminal Mode is the default setting.
In Terminal Mode:
You change configuration parameters by selecting menu options that appear on a VT100-compatible terminal attached to the front panel of the termination unit.
The standalone unit is preconfigured at the factory for CP (customer premises) operation.
In Switchpack Mode:
You change configuration parameters by moving switchpacks and jumpers on the board.
The standalone unit is not preconfigured. You must ensure that the switchpacks and jumpers are set as desired.
You can still display information about the unit from the terminal and run loopback tests.
Any changes you make in Terminal Mode are lost when you change to Switchpack Mode.
An optional system maintenance terminal is attached to your Model 7924 standalone termination unit through the modular jack on the front panel. Terminals can be attached to both endpoints (CO and CP).
The system terminal must be a VT100-compatible terminal or a PC running emulation software.

Using Terminal and Switchpack Modes
Connect the 9-pin end of the terminal cable into a COM port on your PC. Plug the other end into the modular jack on the termination unit’s front panel. If your PC requires a 25-pin connector to the COM port, see Appendix B, Cable Pin Assignments, for the correct cable pinouts.
Make sure the terminal parameters on your terminal or PC are set to:
8 bit character
No parity bit
1 stop bit
No flow control
Press Return at your terminal to activate the Main Menu. The system runs diagnostics and status checks as it comes up. After a few seconds, the Main Menu screen appears on your terminal. Menus are described in Chapters 4 and 5 for the DSX-1 and V.35 units, respectively.
The following procedure is used to change the operating mode of the unit to either Terminal Mode (the default setting) or Switchpack Mode. Refer to Chapter 4 (for DSX-1-compatible units) or Chapter 5 (for V.35-compatible units) for information on changing configuration options using either of these modes.
Use electrostatic discharge protection when handling the circuit board.
To change the mode:
— Use jumper P11 for DSX-1-compatible units.
— Use jumper P8 for V.35-compatible units.
— Switchpack Mode is configured by placing the jumper on Pins 2 and 3.
— Terminal Mode is configured by placing the jumper on Pins 1 and 2.
9600 Kbps

Accessing Configuration Options
This chapter explains how to change configuration options for HotWire 7924-A1 standalone units that are DSX-1-compatible. Chapter 5 provides similar information for V.35-compatible units.
Configuration option settings determine how the unit operates. You can change a unit’s configuration options by:
Selecting the Board Configuration branch of the Main Menu while in Terminal Mode.
Changing switchpack and jumper settings on the circuit board while in Switchpack Mode.
The Main Menu for a DSX-1-compatible unit on the customer premises (CP) side appears as follows:
The G123 code denotes a successful startup
ATTX – CP – T1 Rate – LOOP AB
T1 HDSL HTUR Main Menu
CP units are HDSL Termination Units – Remote (HTUR) CO units are HDSL Termination Units – Central Office (HTUC)
Command→ G123 · Command→

This guide depicts the system terminal menus as they appear from a CP unit. This is the default configuration for Model 7924 standalone units.
The Board Configuration menu displays the current board software and hardware settings. It also allows you to change certain parameters on the board.
This function is affected by the status of the switchpack (DIP switch control) setting.
When operating in Terminal Mode (the system default) you can make configuration changes through the terminal menus.
When operating in Switchpack Mode, you can display configuration parameters using the terminal menus, but any configuration changes must be made using the switchpacks and jumpers on the board hardware. Refer to Making Changes in Switchpack Mode on page 4-5.
To access the Board Configuration menu, enter 3 at the Main Menu Command prompt.
Board Configuration:
1–5) Board Configuration 6) Switch pack Definitions 7) Line Build–Out Definitions ?) Redisplays this menu Q) Quit
Possible values for each parameter are listed in Table 4-1. See Appendix A, Worksheets, for help in selecting the appropriate configuration options for your application.

Indicates the placement of the unit in the network configuration. To toggle the card type, enter 1 at the Config prompt.
CP – Unit is on the customer premises (remote) side of the HDSL connection.
CO – Unit is on the central office (or central site) side of the HDSL connection.
Specifies which loops on the HDSL line are to be used in the connection. To change the loops that are enabled, enter 2 at the Config prompt. The system then prompts you to specify either (S)ingle or (D)ual Loops.
Dual – Loops A and B are enabled.
Single – Only Loop A is enabled.
Specifies the type of line encoding used to ensure ones density in the transmission signal. To toggle the encoding method, enter 3 at the Config prompt.
B8ZS – Binary 8 Zero Substitution.
AMI – Alternate Mark Inversion.
Specifies the type of framing to be used. To toggle the framing method, enter 4 at the Config prompt.
D4 – Commonly used framing method on T1 circuits, consisting of 12 frames of 192 bits with the 193rd bit used for error checking and other functions. Also called Super Framing.
Extended Superframe – Framing method consisting of 24 frames of 192 bits each, with the 193rd bit providing timing and other functions. An enhanced version of D4.
Unframed – Framing is disabled.
Customizing DSX-1-Compatible Units

Possible Settings: 0 to 133 ft, 133 to 266 ft, 266 to 399 ft, 399 to 533 ft, 533 to 655 ft Default Setting: 0 to 133 ft
To change the line build-out length, enter 5 at the Config command prompt. You will then be prompted to select from the following options:
You must reset the board for changes to the card type or loops enabled (options 1 or 2) to take effect. A system message is displayed on the terminal to remind you to reset the board. To reset the board, choose option 4 from the Main Menu or cycle the power to the board.
All configuration settings are stored in nonvolatile memory and are not affected by the reset.
The HDSL rate type, firmware revision numbers, and the serial number displayed on the Board Configuration screen cannot be changed.
Customizing DSX-1-Compatible Units · N) No change

When operating in Switchpack Mode, you can change configuration options by moving switches on the board hardware.
To enable Switchpack Mode, refer to Switching Between Terminal and Switchpack Modes in Chapter 3, Using Terminal and Switchpack Modes.
Use electrostatic discharge (ESD) protection when handling the circuit board.
To open the unit and make changes while in Switchpack Mode:
For example, to change a unit’s card type from CO to CP, move switch 1 on switchpack S1 to the OFF position.
Enter 6 at the Config prompt to display the definition of each position in the switchpack. Switchpack definitions are also listed in Appendix C, Switchpacks and Jumpers.
Customizing DSX-1-Compatible Units · Config→ 6 · Config→

Enter 7 at the Config prompt to display the switchpack and board settings for line build-out. Use this information to change the line build-out parameter manually. (Switchpack definitions are also listed in Appendix C, Switchpacks and Jumpers.)
Switchpack Settings Position #4 – Bit 0 OFF=0, ON=1 Position #5 – Bit 1 OFF=0, ON=1 Position #6 – Bit 2 OFF=0, ON=1
************ Switchpack Definitions ************ Bit 2 Bit 1 Bit 0 Application 0 to 133 feet – 0dB 0 0 1 133 to 266 feet 0 1 0 266 to 399 feet 0 1 1 399 to 533 feet 1 0 0 533 to 655 feet 1 0 1 -7.5 dB 1 1 0 -15 dB 1 1 1 -22.5 dB
For example, to change the line build-out to 399 to 533 feet, while in Switchpack Mode, set position 6 OFF and positions 4 and 5 ON.
The switch combinations for –7.5, –15, and –22.5 dB line build-out are not for use with this product. Use of these settings will cause a weak signal and degrade performance.
Customizing DSX-1-Compatible Units · Config→ 7 · Config→

Accessing Configuration Options
This chapter explains how to change configuration options for HotWire 7924-A1 models that are V.35-compatible. Chapter 4 provides similar information for DSX-1-compatible units.
Configuration option settings determine how the unit operates. You can change a unit’s configuration options by:
Selecting the Board Configuration branch of the Main Menu while in Terminal Mode.
Changing switchpack and jumper settings on the circuit board while in Switchpack Mode.
The Main Menu for a V.35-compatible unit on the customer premises (CP) side appears as follows:
The G123 code denotes a successful startup
ATTX – CP – T1 – LOOP AB V.35 T1 HDSL HTUR Main Menu
CP units are HDSL Termination Units – Remote (HTUR) CO units are HDSL Termination Units – Central Office (HTUC)
This guide depicts the system terminal menus as they appear from a CP unit. This is the default configuration for Model 7924 standalone units.
Command→ G123 · Command→

Customizing V.35-Compatible Units
The Board Configuration menu displays the current board software and hardware settings. It also allows you to change certain parameters on the board.
This function is affected by the status of the switchpack (DIP switch control) setting.
When operating in Terminal Mode (the system default) you can make configuration changes through the terminal menus.
When operating in Switchpack Mode, you can display configuration parameters using the terminal menus, but any configuration changes must be made using the switchpacks and jumpers on the board hardware. Refer to Making Changes in Switchpack Mode on page 5-4.
To access the Board Configuration menu, enter 3 at the Main Menu Command prompt.
Board Configuration:
1–3) Board Configuration 4) Switch pack Definitions ?) Redisplays this menu Q) Quit
Command→ 3 · · Config→

Customizing V.35-Compatible Units
Possible values for each parameter are listed in Table 5-1. See Appendix A, Worksheets, for help in selecting the appropriate configuration options for your application.
Indicates the placement of the unit in the network configuration. To toggle the card type, enter 1 at the Config prompt.
CP – Unit is on the customer premises side of the HDSL connection.
CO – Unit is on the central office (or central site) side of the HDSL connection.
Specifies which loops on the HDSL line are to be used in the connection. To change the loops that are enabled, enter 2 at the Config prompt. The system then prompts you to specify either (S)ingle or (D)ual Loops.
Dual – Loops A and B are enabled.
Single – Only Loop A is enabled.
Specifies the desired payload rate.
Options 8 and 9 (1024 and 1536 kbps) are only available when Loops A and B are enabled. If only Loop A is enabled, the maximum payload rate is 768 kbps (option 7).
You must reset the board for changes to the card type or loops enabled (options 1 or 2) parameters to take effect. A system message is displayed on the terminal to remind you to reset the board. To reset the board, choose option 4 from the Main Menu or cycle the power on the board.
All configuration settings are stored in nonvolatile memory and are not affected by the reset.
The transmit timing, HDSL interface/rate, firmware revision numbers, and serial number displayed on the Board Configuration screen cannot be changed.

Customizing V.35-Compatible Units
When operating in Switchpack Mode, you can change configuration options by moving switches on the board hardware.
To enable Switchpack Mode, refer to Switching Between Terminal and Switchpack Modes in Chapter 3, Using Terminal and Switchpack Modes.
Use electrostatic discharge (ESD) protection when handling the circuit board.
To open the unit and make changes while in Switchpack Mode:
For example, to change a unit’s card type from CO to CP, move switch 1 on switchpack S1 to the OFF position.

Customizing V.35-Compatible Units
Enter 4 at the Config prompt to display the definition of each position in the two switchpacks. Switchpack definitions are also listed in Appendix C, Switchpacks and Jumpers.
Switch pack 1 definition:
Switch pack 2 definition:
Config→ 4 · Config→

What to Monitor
This chapter presents information on how to access and monitor status and performance statistics for the unit and its network connection. You can monitor operations by viewing the:
Board Status option from the Main Menu
Performance Monitor option from the Main Menu
Board Status and Performance Monitor options from the HTUC (or HTUR) menu (for displaying information about the unit on the other end of the connection)
Front Panel LEDs

Board Status option from the Main Menu displays HDSL circuit operational status.
Enter 1 at the Main Menu Command prompt to display board status.
DTR: ACTIVE DSR: ACTIVE
LOOPBACK STATUS: OFF
S/N RATIO: Loop A = 44.0 dB, Loop B = 43.5 dB.
T1 STATUS displays one of the following:
— Network is Up
— Receive Carrier Loss
— Receive Remote Alarm
— Receive Unframed All 1’s.
DTR and DSR are either ACTIVE or INACTIVE. DSR becomes active in response to DTR (with HDSL loops up and data transmission possible).
LOOPBACK STATUS is either ON or OFF.
HDSL STATUS displays whether each loop is UP, DOWN, or DISABLED.
S/N (Signal-to-Noise) RATIO is not displayed if loops are down or disabled.

Performance monitoring allows detailed observations of error conditions detected on the circuits. Performance Monitor statistics can be displayed in defined time periods from the previous minute to the previous 24 hours, plus a running total. These statistics can be cleared and restarted at any time.
Performance statistics are updated every second.
Enter 2 at the Main Menu Command prompt to display the Performance Monitor menu.
Time Since Board Power–Up or Reset: 0000d 00h 00m 00s 1 – 1 minute stats. 2 – 15 minute stats. 3 – 1 hour stats. 4 – 12 hour stats. 5 – 24 hour stats. 6 – Running total. 7 – Clear Statistics. Q – Quit
Select a time frame from the list to display statistics for a specified time period.
Accumulated performance statistics may be cleared and restarted by selecting option 7 on the Performance Monitor menu.
Be sure you want to clear all statistics before pressing 7. There is no verification dialog.
Monitoring the Unit · Command→ 2 · stats→

FAW LoopA – 0 BPV – 0 FAW LoopB – 0 CRC – 0 CRC LoopA – 0 MOS – 0 CRC LoopB – 0 FEBE LoopA – 0 FEBE LoopB – 0
Previous 1 minute:
FAW LoopA – 0 BPV – 0 FAW LoopB – 0 CRC – 0 CRC LoopA – 0 MOS – 0 CRC LoopB – 0 FEBE LoopA – 0 FEBE LoopB – 0
Current 1 minute: HDSL Errors: FAW LoopA 0 FAW LoopB 0 CRC LoopA 0 CRC LoopB 0 FEBE LoopA 0 FEBE LoopB 0
Previous 1 minute HDSL Errors: FAW LoopA 0 FAW LoopB 0 CRC LoopA 0 CRC LoopB 0 FEBE LoopA 0 FEBE LoopB 0

The type of statistics displayed under the T1 Errors column depends on the type of framing selected. When the unit is configured for D4 framing, FAS (Frame Alignment Signal) errors are reported. When the unit is configured for ESF framing, CRC (Cyclic Redundancy Check) errors are reported.
Refer to the Glossary for definitions of the errors reported.
The same type of information provided for the locally attached unit can also be displayed (but not changed) for the unit on the other side of the connection.
You can display information about the CO unit by using the HTUC menu options from a terminal attached to the CP unit, and you can display information about the CP unit by using the HTUR menu options from a terminal attached to the CO unit.
To access the HTUC or HTUR menu, enter 7 at the Main Menu Command prompt.
***** HTUC Menu ***** 1) Board Status 2) Performance Monitor 3) Board Configuration 4) Line Build Out Configuration Help ?) Redisplays this Menu Q) Quit
Monitoring the Unit · HTUC Command→

Upon power up, the first three LEDs blink in sequence, indicating a successful start configuration. The green PWR LED lights whenever power is applied to the board. Loop LEDs blink until the loop has been synchronized and then remain off.
NETWORK SYSTEM HDSL
PWR
FAIL
TM
LED Meaning
Local ON: The local T1 interface has a loss of signal.
Remote ON: The remote T1 interface has a loss of signal.
Loop Bk ON: A loopback has been initiated for testing the equipment connected to this unit. Refer to Chapter 7, Testing, for more information.
PWR ON: Power is applied to the unit.
FAIL ON: The processor has halted and repairs are required.
Loop A ON: HDSL Loop A has failed.
Blinking: HDSL Loop A is synchronizing with the far-end unit (such as when the units are coming up after a reset). If the LED blinks for more than 60 seconds, loss of signal has occurred.
Off: Loop A is enabled and synchronized.
Loop B ON: HDSL Loop B has been disabled (only Loop A is in use) or has failed.
Blinking: HDSL Loop B is synchronizing with the far-end unit (such as when the units are coming up after a reset). If the LED blinks for more than 60 seconds, loss of signal has occurred.
Off: Loop B is enabled and synchronized.

The green PWR LED lights whenever power is applied to the board. Loop LEDs blink until the loop has been synchronized and then remain off.
DTR
DSR
RXD
PWR
FAIL
CTS
RTS
TXD
LED Meaning
Loop Bk ON: A loopback has been initiated for testing the equipment connected to this unit. Refer to Chapter 7, Testing, for more information.
PWR ON: Power is applied to the unit.
FAIL ON: The processor has halted and repairs are required.
Loop A ON: HDSL Loop A has failed.
Blinking: HDSL Loop A is synchronizing with the far-end unit (such as when the units are coming up after a reset). If the LED blinks for more than 60 seconds, loss of signal has occurred.
Off: Loop A is enabled and synchronized.
Loop B ON: HDSL Loop B has been disabled (only Loop A is in use) or has failed.
Blinking: HDSL Loop B is synchronizing with the far-end unit (such as when the units are coming up after a reset). If the LED blinks for more than 60 seconds, loss of signal has occurred.
Off: Loop B is enabled and synchronized.

Detecting a Problem
The unit can detect and report problem conditions and perform diagnostic tests. The unit offers a number of indicators to alert you to possible problems, as described in Chapter 6, Monitoring the Unit:
Front Panel LEDs
Board status and performance statistics
Remote unit board status and performance statistics
Loopback is a diagnostic function that enables a technician to isolate equipment on the HDSL circuit to determine where on the circuit trouble may be occurring. Loopback takes the system off-line. Data received from the DTE (T1 or V.35 application equipment) is looped back, as depicted in Figures 7-1 through 7-4.
“Local” and “remote” refer to the point at which the data is looped back. In a local loopback the data is reflected back by the local unit (the unit that initiated the loopback). In a remote loopback, the data is passed on to the remote (far-end) unit and then reflected back.
Loopback tests are initiated through the terminal interface from either the CO or CP side of the HDSL connection.

When a local loopback is enabled, the red Loop Bk LED on the front panel of the initiating unit lights up and remains lit until the loopback is disabled.
The data flow is indicated by the bold thick arrows in Figures 7-1 and 7-2.
When the CO initiates a local loopback, an Alarm Indication Signal (AIS) is received at the CP end (only if the CP end is G.703-compatible). (AIS is not received at V.35-compatible CP units.)
AIS

CO CP

Testing · Terminal 97-15514-01 · Terminal 97-15518-01

When a remote loopback is enabled, the red Loop Bk LED on the front panel of the remote-end unit (CO or CP) lights up and remains lit until the loopback is disabled. The loopback LED on the initiating unit does not light.
A message appears on the remote-end unit reporting that it has been put into loopback.
The data flow is indicated by the bold thick arrows in Figures 7-3 and 7-4.
When the CO initiates a remote loopback, an Alarm Indication Signal (AIS) is received at the CP end (only if the CP end is G.703-compatible). (AIS is not received at V.35-compatible CP units.)
AIS

CO CP

Testing · Terminal 97-15515-01 · Terminal 97-15517-01

To start or stop a local loopback test, enter 5 at the Main Menu Command prompt.
Local Loopback is Enabled!
Local Loopback is Disabled!
To start or stop a remote loopback test, enter 6 at the Main Menu Command prompt.
Remote Loopback is Enabled!
Remote Loopback is Disabled!
When you stop a loopback test (local or remote), both units automatically reset themselves in order to return to normal operation.
A loopback may not be started on units that have just been reset. After a reset, the units require approximately one minute for the circuit (HDSL connection) to stabilize. If you attempt to start a loopback during this time, the following error message appears: “PLEASE WAIT! Circuit is stabilizing.”
Only one loopback may be run at a time. If a loopback is already enabled, the following error message appears and no other loopback may be started until the first loopback is disabled: “CANNOT EXECUTE COMMAND! Current loopbacks must be removed first.”

To reset the board, enter 4 at the Main Menu Command prompt. This is equivalent to cycling the power.
Reset will bring the loops down. Are you sure? (y/n)
If “y” is selected, the Main Menu reappears, the loops go down, and the FAIL (reset) LED lights up.
Pressing any key other than “y” is interpreted as an “n”.
Testing · Command→ 4 · Command→

A
Overview
The worksheets in this appendix show the correct configuration settings based on the types of units (DSX-1-compatible or V.35-compatible) on either end of the HDSL connection. There are two combinations of the two types of units:
DSX-1-compatible units on both ends
V.35-compatible unit on the CP end, DSX-1-compatible unit on the CO end
HotWire 7924 V.35-compatible units are not designed for use at both ends of an HDSL connection. If your application requires V.35 equipment at both ends of an HDSL connection, consider using two Hotwire 7925 E1 HDSL termination units. Contact your sales representative for more information.
A-1 7924-A2-GB20-30 October 1997


Customer Premises Central Site
To connect two DSX-1-compatible units, configure the units as follows. Terminal mode factory defaults are in bold (for Switchpack mode defaults, see Appendix C, Switchpacks and Jumpers).

Loops Enabled Dual (Loops A & B) or Single (Loop A)
T1 Line Encode B8ZS or AMI Must be same as CP side
Line Build-Out Enter 5 at the Config command prompt. Select from the following options:
Enter 5 at the Config command prompt. Select from the following options:
A-2 7924-A2-GB20-30 October 1997
Worksheets · 97-15296

DSX-1
V.35 Unit
To connect a V.35-compatible unit on the CP side and a DSX-1-compatible unit on the CO side, configure the units as follows. Terminal mode factory defaults are in bold (for Switchpack mode defaults, see Appendix C, Switchpacks and Jumpers).
V.35-Compatible Unit (Customer Premises)
DSX-1-Compatible Unit (Central Site)
Card Type CP CO
Loops Enabled Dual (Loops A & B) or Single (Loop A)
Must be same as CP side
Payload Rate 1 – 9 (64 – 1536 kbps) Options 8 (1024 kbps) and 9 (1536 kbps) are only available if both Loops A & B are enabled.
Framing N/A Use D4, Extended Superframe, or Unframed. See Unframed Operation on page A-4 before selecting Unframed.
T1 Line Encode N/A B8ZS or AMI
Line Build-Out N/A Enter 5 at the Config command prompt. Select from the following options:
A-3 7924-A2-GB20-30 October 1997

Some units do not support unframed operation. To determine whether or not your DSX-1-compatible unit supports unframed operation when connected to a V.35-compatible unit, all three of the following conditions must be true:
If you have a DSX-1-compatible standalone unit, display the HDSL FW (firmware) revision number by selecting the Board Configuration option (3) from the Main Menu (a system terminal is required).
If you have a DSX-1-compatible nest-mounted unit, refer to the HotWire Models 7924 and 7925 T1 and E1 HDSL Nest Card Termination Units User’s Guide.
To display the HDSL FW (firmware) revision number, select the Board Configuration option (3) from the Main Menu (a system terminal is required).
To determine the hardware revision number, look at the label on the bottom of the standalone unit that has the “CE” and “CSA” logos. The second row of numbers on this label should be “900P005705” or higher. The last two digits of this number (05) indicate the hardware revision number.
When the V.35 payload rate is set for less than 1536 kbps, that payload rate determines which T1 DS0s are used, as follows:
1 (64 kbps) 1
2 (128 kbps) 1, 2
3 (192 kbps) 1 – 3
4 (256 kbps) 1 – 4
5 (384 kbps) 1 – 6
6 (512 kbps) 1 – 8
7 (768 kbps) 1 – 12
8 (1024 kbps) 1 – 16
A-4 7924-A2-GB20-30 October 1997
Worksheets

Configuration Option Settings Default in Bold
Card Type CP, CO
Loops Enabled Dual, Single
T1 Line Encode B8ZS, AMI
Framing D4, Extended Superframe, Unframed
Line Build Out 1) 0 to 133 feet – 0 dB 2) 133 to 266 feet 3) 266 to 399 feet 4) 399 to 533 feet 5) 533 to 655 feet
Configuration Option Settings Default in Bold
Card Type CP, CO
Loops Enabled Dual, Single
Payload Rate 1 – 1 x 64 (64 kbps) 2 – 2 x 64 (128 kbps) 3 – 3 x 64 (192 kbps) 4 – 4 x 64 (256 kbps) 5 – 6 x 64 (384 kbps) 6 – 8 x 64 (512 kbps) 7 – 12 x 64 (768 kbps) 8 – 16 x 64 (1024 kbps)1 9 – 24 x 64 (1536 kbps)1 N – No change to rate
1 Options 8 and 9 require Loops A and B.
A-5 7924-A2-GB20-30 October 1997
Worksheets

B
Terminal Connection Cable Pin Assignments
This section defines the pin assignments for the terminal cable from the front panel modular jack to your PC’s COM port.
If your PC’s COM port requires a 9-pin D-shell connector, the cable must use the following pin assignments.
TXD
TXD
RXD
GND
GND
DCD
DTR
DSR
RTS
CTS
B-1 7924-A2-GB20-30 October 1997

If your PC’s COM port requires a 25-pin D-shell connector, the cable must use the following pin assignments.
TXD
TXD
RXD
GND
GND
DSR
DCD
DTR
RTS
CTS
HDSL Loop Connection Cable Pin Assignments
The HDSL modular connector that plugs into the rear panel of the unit has the following pin assignments.
1 Loop A Tip
2 Loop A Ring
3 Loop B Tip
4 Loop B Ring
Pin 1 is on the left when viewing the jack from its inserted position.
B-2 7924-A2-GB20-30 October 1997

The modular connector that plugs into the rear panel of DSX-1-compatible units has the following pin assignments.
Pin 1 is on the left when viewing the jack from its inserted position.
B-3 7924-A2-GB20-30 October 1997

The connector that plugs into the rear panel of V.35-compatible units has the following pin assignments.

102 B SG Signal Ground Ground reference for all circuits
105 C RTS ← Request to Send DTE has message to send
106 D CTS → Clear to Send DCE is ready to accept and transmit DTE data
107 E DSR → Data Set Ready DCE is ready to operate
109 F RLSD → Data Channel Received Line Signal Detector
108 H DTR ← Data Receiver Ready DTE is ready to operate
103 P TXD ← Transmit Data (A) Data generated by DTE
104 R/D RXD → Received Data (A) Data received by DTE
103 S TXD ← Transmitted Data (B) Data generated by DTE
104 R RXD → Received Data (B) Data received by DTE
To help detect center of signaling element on BA
115 V RSET → Receiver Signal Element Timing (A)
To help detect center of signaling element on BB
To help detect center of signaling element on BA
115 X RSET → Receiver Signal Element Timing (B)
To help detect center of signaling element on BB
114 Y TSET → Transmit Signal Element Timing (A)
To help detect center of signaling element on BA
114 a TSET → Transmit Signal Element Timing (B)
To help detect center of signaling element on BB
142 n TST → Test Indicator Reserved for test
B-4 7924-A2-GB20-30 October 1997
Cable Pin Assignments

DSX-1-Compatible Units
Use Figure C-1 to assist you in locating the switchpacks and jumpers on the board.
The jumper and switchpack detailed in Figure C-1 are used to change configuration options. All other jumpers (listed below) must remain as positioned at the factory.
P1 2–3
P8 2–3
P9 2–3
P10 1–2
P11 1–2
P12 1–2
C-1 7924-A2-GB20-30 October 1997
P3 No Jumper


OFF = AMI line encoding ON = B8ZS line encoding
OFF = Loops A and B ON = Loop A
000 = 0–133 ft 100 = 133–266 ft 010 = 266–399 ft 110 = 399–533 ft 001 = 533–655 ft
00 = Unframed 01 = D4 11 = ESF
* Default in bold
Pin 1 on jumpers is labeled on the board.
The ON position is labeled on the switchpack.
Positions 4, 5, and 6 on Switchpack S1 work as a group. Set position 4 to the first digit, position 5 to the second digit, and position 6 to the last digit. For example, set 4 and 5 ON and 6 OFF for 399–533 ft.
Positions 7 and 8 on Switchpack S1 work as a pair. Set position 7 to the first digit and position 8 to the second digit. For example, set 7 OFF and 8 ON for D4 framing.
C-2 7924-A2-GB20-30 October 1997

Use Figure C-2 to assist you in locating the switchpacks and jumpers on the board.
The jumper and switchpacks detailed in Figure C-2 are used to change configuration options. All other jumpers (listed below) must remain as positioned at the factory.
P1 1–2
P2 1–2
P4 2–3
P8 1–2
P9 2–3
P10 2–3
P11 1–2
C-3 7924-A2-GB20-30 October 1997
Switchpacks and Jumpers · P5 No Jumper


OFF = Loops A and B ON = Loop A
* Default in bold
Pin 1 on the jumper is labeled on the board.
The ON position is labeled on the switchpacks.
Positions 4 and 5 on Switchpack S1 work as a pair. Position 4 should be ON and position 5 should be OFF. No other combinations are valid.
C-4 7924-A2-GB20-30 October 1997

Alternate Mark Inversion coding format.
Bipolar Violation. A type of error detected by using a modified bipolar signaling method in which a control code is inserted. Used with AMI coding format.
Bipolar with eights and Zeroes Substitution. An encoding scheme for transmitting clear channel signals over a T1 line.
Carrier Detect. A signal indicating that energy exists on the transmission circuit. Associated with Pin 8 on an EIA-232 interface.
Central Office. As used in this manual, CO denotes any central site as distinguished from the Customer Premises site.
Communications port. A computer’s serial communications port used to transmit to and receive data from a DCE. The DCE connects directly to this port.
Customer Premises.
Customer Premises Equipment. Terminating equipment supplied by either the customer or some other supplier that is connected to the telecommunications network (e.g., DSUs, terminals, phones, routers, modems).
Cyclic Redundancy Check. A commonly used method of error detection.
Clear to Send. An EIA-lead standard for V.24 circuit CT 106; an output signal (DCE-to-DTE).
Code Violation. This is equivalent to a BPV. Used with HDB3 coding format.
Data Communications Equipment. The equipment that provides the functions required to establish, maintain, and end a connection. It also provides the signal conversion required for communication between the DTE and the network.
Data Set Ready. An EIA-lead standard for V.24 circuit CT 107; an output signal (DCE-to-DTE).
Digital Signal cross-connection (of network equipment) at T1 rates.
Digital Signal level 1. A framing specification for T1 circuits.
Data Terminal Equipment. The equipment, such as computers, printers, and routers, that provide or create data.
Data Terminal Ready. An EIA-lead standard for V.24 circuit CT 108; an input signal (DTE-to-DCE).
A data signaling rate common outside the United States. A wideband interface operating at 2.048 Mbps defined by CCITT standards G.703 and G.704.
A predetermined set of configuration options for general operation.
Frame Alignment Signal. A loss of signal (LOS) error detection.
Frame Alignment Word. A loss of synchronization error detection.
GL-1 7924-A2-GB20-30 October 1997

Federal Communications Commission. Board of Commissioners that regulates all U.S. interstate, intrastate, and foreign electrical communication systems that originate from the United States.
Far End Bit Error. Number of errors reported by the remote equipment.
High Density Bipolar 3 coding format.
High-bit-rate Digital Subscriber Loop. Provides high bandwidth, bi-directional transmission over copper wire for both T1 and E1 services.
Host Termination Unit. A generic reference to either an HTU-C or HTU-R module.
Host Termination Unit – Central. The module at the CO (central office) or central site end of an HDSL connection. Also known as a Network Termination Unit (NTU).
Host Termination Unit – Maintenance. A carrier–mounted module used to perform maintenance operations on one or more HTU-R and HTU-C modules.
Host Termination Unit – Remote. The module at the CP (customer premises) end of an HDSL connection. Also known as a Line Termination Unit (LTU).
Light Emitting Diode. A status indicator that responds to the presence of a certain conditions.
Used to test various portions of a data link in order to isolate an equipment or data line problem. A diagnostic procedure that sends a test message back to its origination point.
Multiframes Out of Sync. A performance statistic that counts the number of multiframes received out of sync.
Out Of Frame. An error condition in which frame synchronization bits are in error. A network-reported condition.
A reinitialization of the device that occurs at power-up or in response to a reset command.
Request to Send. An EIA-lead standard for V.24 circuit CT 105; an input signal (DTE-to-DCE).
Received Data. An EIA-lead standard for V.24 circuit CT 104; an output signal (DCE-to-DTE).
A data signaling rate common in the United States. A term for a digital carrier facility used to transmit a DS1 formatted signal of 1.544 Mbps.
Transmit Data. An EIA-lead standard for V.24 circuit CT 103; an input signal (DTE-to-DCE).
ITU-T standard for a high-speed, 34-pin, DCE/DTE interface.
GL-2 7924-A2-GB20-30 October 1997
Glossary

R
rear panel diagram, 2-2 related documents, vi remote loopback test, 7-3 remote unit, accessing menu of, 6-5 resetting the unit, 4-4, 5-3, 7-5
DSX-1 compatible unit, C-1 procedure for setting, 3-2 V.35 compatible unit, C-3
DSX-1 compatible unit, 6-6 V.35 compatible unit, 6-7 line build out
service information, A statistics, performance monitoring, 6-3 switchpack mode
how to display, 4-6 options, 4-4 line encoding options, 4-3 local loopback test, 7-2 loopback tests, 7-1
changing to, 3-2 described, 3-1 DSX-1 compatible units, 4-5 V.35 compatible units, 5-4 switchpacks
local, 7-2 remote, 7-3 starting and stopping, 7-4 loops enabled
DSX-1 compatible unit, C-1 V.35 compatible unit, C-3 how to display, 4-5, 5-5
DSX-1 compatible units, 4-3 V.35 compatible units, 5-3
terminal cable pin assignments, B-1 terminal interface, 3-1 terminal mode
changing to, 3-2 connecting terminal for, 3-1 described, 3-1 testing, 7-1
DSX-1 compatible units, 4-1 V.35 compatible units, 5-1 model numbers, 1-2 monitoring
local loopback, 7-2 remote loopback, 7-3 starting and stopping, 7-4 time slot assignments, A-4
board status, 6-2 performance statistics, 6-3 remote unit, 6-5
U
network performance statistics, 6-3
restrictions on use, A-4 user interface, 1-5, 3-1
parts list, 2-1 payload rate options, 5-3 PC requirements, 3-2 performance statistics, 6-3 pin assignments, B-1 power cord installation, 2-2
V.35 to DSX-1 configuration, A-3 VT100 interface, 3-1
warranty telephone number, A worksheets, A-1
IN-2 7924-A2-GB20-30 October 1997