WITH INTERNAL ETHERNET LAN ADAPTER
USER’S GUIDE
March 1998

Copyright 1998 Paradyne Corporation. All rights reserved. Printed in U.S.A.
This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Avenue North, P.O. Box 2826, Largo, Florida 33779-2826.
Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.
Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual.
All products and services mentioned herein are the trademarks, service marks, registered trademarks or registered service marks of their respective owners.
Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
Via Telephone: Call our automated call system to receive current information via fax or to speak with a
company representative.
— Within the U.S.A., call 1-800-870-2221 — Outside the U.S.A., call 1-727-530-2340
Printed on recycled paper
A 7112-A2-GB20-20 March 1998


Document Purpose and Intended Audience
This guide contains information needed to set up, configure, and operate the Model 7112 T1 DSU/CSU and is intended for use by installers and operators.
Chapter 1 About the T1 DSU/CSU. Describes the DSU/CSU features and SNMP management capabilities with a typical configuration example.
Chapter 2 Using the ASCII Terminal Interface. Provides instructions for accessing the user interface and navigating the screens.
Chapter 3 Configuring the DSU/CSU. Provides procedures for setting up the user interface, and DSU/CSU configuration steps.
Chapter 4 Security. Presents procedures for creating a login, setting the effective access levels, and controlling SNMP access.
Chapter 5 IP Addressing. Provides details regarding IP addresses with examples.
Chapter 6 Monitoring the DSU/CSU. Describes monitoring details about the LEDs, DSU/CSU status, and network statistics.
Chapter 7 Testing. Provides details about available tests and test setup.
Chapter 8 Messages and Troubleshooting. Provides information on SNMP traps, device messages, and troubleshooting.
vii 7112-A2-GB20-20 March 1998

Appendix A Configuration Option Tables. Contains all configuration options, default settings, and possible settings.
Appendix B Worksheets. Contains all the configuration options, default settings, and possible settings to use for planning.
Appendix C MIB Descriptions. Provides all MIBs supported by the DSU/CSU.
Appendix D Standards Compliance for SNMP Traps. Contains SNMP trap compliance details.
Appendix E Cables and Pin Assignments. Contains connector and interface details.
Appendix F Technical Specifications. Contains physical and regulatory specifications, network and port interfaces, power consumption values, etc.
Glossary Defines acronyms and terms used in this document.
Index Lists key terms, acronyms, concepts, and sections in alphabetical order.
7112-A2-GN10 Model 7112 T1 DSU/CSU with Internal Ethernet LAN Adapter Startup Instructions
Contact your sales or service representative to order additional product documentation.
Paradyne documents are also available on the World Wide Web at:
Select Service & Support → Technical Manuals
viii 7112-A2-GB20-10 March 1998
About This Guide

Model 7112 T1 DSU/CSU Features

The 7112 T1 DSU/CSU provides an interface between the T1 digital network and the customer premises equipment, converting signals received from the DTE (Data Terminal Equipment) to bipolar signals that can be transmitted over T1 lines.
The T1 DSU/CSU offers these features:
10BaseT Port. Allows the DSU/CSU to connect directly to an Ethernet LAN.
SNMP (Simple Network Management Protocol) Management. Provides network management via an industry-standard SNMP management system.
Facility Data Link (FDL). Provides remote management via SNMP or Telnet session capability over the T1 network.
ASCII Terminal Interface (ATI). Provides a menu-driven VT100-compatible interface for configuring and managing the DSU/CSU locally or remotely by Telnet session or External Modem.
Two Customer-Specified Configuration Storage Areas. Allows quick access to alternate sets of configuration options.
97-15692

About the T1 DSU/CSU
Management. Provides management via:
— ASCII terminal connection through the Terminal port
— External modem through the Terminal port
— Telnet through the Ethernet port or the FDL
— SNMP through Ethernet port or the FDL
Alarm Indication. Activates front panel LEDs.
Diagnostics. Provides the capability to diagnose device and network problems and perform tests, including digital loopbacks, pattern tests, and self-test.
Device and Test Monitoring. Provides the capability of tracking and evaluating the unit’s operation, including health and status, and error-rate monitoring.
Security. Provides multiple levels of security, which deters unauthorized access to the DSU/CSU.
Figures 1-1 and 1-2 show typical LAN/WAN interconnection applications for the DSU/CSU. The routers connected to the DSU/CSU at each location provide the LAN interconnection.

Two SNMP DSUs can be connected back-to-back to act as Local Area Data Sets.
DSU/CSU
Figure 1-2. Typical Configuration (DSU/CSU to DSU/CSU)
Router · Router

About the T1 DSU/CSU
There are three types of user interfaces to the T1 DSU/CSU:
Menu-driven ASCII terminal interface screens (see Chapter 2, Using the ASCII Terminal Interface (ATI)).
SNMP NMS Access – Refer to Model 7112 T1 DSU/CSU Features on page 1-1. Provides the capability to access the DSU/CSU via an SNMP management system connected to the Ethernet port or remotely through the Facility Data Link (FDL). Refer to Chapter 5, IP Addressing.
Front panel LED status indicators. Refer to Chapter 6, Monitoring the DSU/CSU.
Refer to Chapter 6, Monitoring DSU/CSU LEDs.
TXD (103)
RXD (104)
RTS (105)
CTS (106)
DTR (108)
TEST
ALARM
MONITOR
OK
FAIL
SIG
OOF
EER
Network System Port FT1/T1
In Out · 97-15687

About the T1 DSU/CSU
Figure 1-4 shows the physical interfaces of the DSU/CSU. Information about the installation of the DSU/CSU is contained in Model 7112 T1 DSU/CSU with Internal Ethernet LAN Adapter Startup Instructions.

CAUTION:
The 10BaseT and Network connectors are not keyed. Follow the installation procedures carefully to avoid connection errors.
The DSU/CSU supports SNMP Version 1, and has the capability of being managed by any industry-standard SNMP manager and accessed using SNMP protocol by external SNMP managers.
The following MIBs are supported:
MIB II (RFC 1213 and RFC 1573) – Defines the general objects for use with a network management protocol in TCP/IP internets and provides general information about the DSU/CSU. MIB II is backward-compatible with MIB I.
Ethernet-like MIB (RFC 1643) – Defines objects for managing Ethernet-like interfaces (e.g., 10BaseT).
RS-232-Like MIB (RFC 1659) – Defines objects for managing RS-232-type interfaces and supports the V.35 synchronous data port on the DSU/CSU.
Enterprise MIB – Supports configuration, status, statistics, and tests on the DS1 network interface.
DS1/E1 MIB (RFC1406) – Defines objects for managing DS1 interfaces and supports the network interface on the DSU/CSU. DS1 Near End Group and DS1 Fractional Group are supported.
Generic-Interface Extension MIB (RFC 1229) (Generic Interface Test table only) – Provides extensions to the generic interface group defined in MIB II.
Terminal · 97-15694

Accessing the ATI
You can communicate with the ATI using one of the following methods:
Direct connection through the Terminal port.
Dialing in through an external modem to the Terminal port.
Telnet session through the Ethernet port.
Telnet session through the Facility Data Link (FDL).
Only one ATI session can be active at a time, and another user’s session cannot be forced to end. To automatically log out a user due to inactivity, enable the Inactivity Timeout option (see Table A-6, Terminal Port Options and Table A-7, Telnet Session Options).
The user interface is blank until activated. Press Enter to activate the user interface. Security can limit ATI access several ways. To setup security or a login ID, refer to Chapter 4, Security.
Ensure that the device you connect communicates using the following settings:
Data rate set to 9.6 kbps.
Character length set to 8.
Parity set to None.
Stop Bits set to 1.
To change Terminal port settings, refer to Table A-6, Terminal Port Options.

Using the ASCII Terminal Interface (ATI)
The Main Menu screen is displayed on the screen unless a login ID and password is required or the ATI is already in use.
If security is enabled, the system prompts you for a login ID and password. After you enter a valid login ID and password, the Main menu appears. If you enter an invalid login ID and password after three attempts, the Telnet session closes or the terminal connection returns to an idle state. Refer to Chapter 4, Security.
If the ATI is already in use, you will see a “connection refused” or “connection failed” message (if you are using a Telnet session) or you will see the IP address of the other user (if you are using the Terminal port).
Entry to all of the DSU/CSU’s tasks begins at the Main Menu screen.
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
MAIN MENU
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Status Test Configuration Control
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Select . . . To . . .
Status View system status, diagnostic test results, cross connections, statistics, and LEDs identity information.
Test Select and cancel tests for the DSU/CSU’s interfaces.
Configuration Display and edit the configuration options.
Control Control the user interface for device naming, login administration, or to initiate a power-up reset of the DSU/CSU.

Using the ASCII Terminal Interface (ATI)
There are two user work areas:
Screen area – Provides the menu path, access level, menus, and input fields above the dotted line.
The menu path appears as the first line on the screen. In this manual, the menu path is presented as a menu selection sequence with the names of the screens For example:
Main Menu →Configuration →Load Configuration From → Edit →Terminal Port
Screen function key area – Provides functions available below the dotted line based upon screen selection and access level.
Three types of screen formats are available on the ATI.
Use the screen format . . . To . . .
Menu selection Display a list of available functions for user selection.
Input Add or change information on a screen.
Input or edit fields that have an Underline in the field value or selection. See Screen Work Areas.
Display Display configuration information and results from performance and DSU/CSU-specific tests.
Display-only fields that have no underline in the field value.
What appears on the screens depends on the:
Current configuration – How your DSU/CSU is currently configured.
Effective security access level – An access level that is typically set by the system administrator for each interface and each user.
Data selection criteria – What you entered in previous screens.

Using the ASCII Terminal Interface (ATI)
You can navigate the screens by:
Using keyboard keys
Using screen function keys
Switching between the two screen work areas
MAIN MENU Status Test Configuration Control
Load Configuration from . . .
Use the following keyboard keys to navigate within the screen.
Press . . . To . . .
Ctrl-a Move cursor between the screen area and the screen function keys area below the dotted line at the bottom of the screen.
Esc Return to the previous screen.
Tab Move cursor to the next field on the screen.
Backspace Move cursor to the previous field on the screen.
Configuration Edit/Display · Control · 97-15686

Using the ASCII Terminal Interface (ATI)
Press . . . To . . .
Enter Accept entry or display valid options on the last row of the screen when pressed before entering data or after entering invalid data.
Ctrl-k Tab backwards (moves cursor one field to the left).
Spacebar Select the next valid value for the field.
Delete (Del) Delete character that the cursor is on.
Up Arrow or Ctrl-u Move cursor up one field within a column on the same screen.
Down Arrow or Ctrl-d Move cursor down one field within a column on the same screen.
Right Arrow or Ctrl-f Move cursor one character to the right if in edit mode.
Left Arrow or Ctrl-b Move cursor one character to the left if in edit mode.
Ctrl-l Redraw the screen display, clearing information typed in but not yet entered.
To make a menu or field selection:
The current setting or value appears to the right of the field name. You can enter information into a selected field by:
Typing in the first letter(s) of a field value or command, using the DSU/CSU’s character matching feature.
Switching from the screen area to the screen function area below the dotted line and selecting or entering the designated screen function key.
If a field is blank and the Field Values screen area displays valid selections, press the spacebar and the first valid value for the field will appear. Continue pressing the spacebar to scroll through other valid values.

Using the ASCII Terminal Interface (ATI)
All screen function keys located below the dotted line operate the same way (upper- or lowercase) throughout the screens.
For the screen function . . . Select . . . And press Enter to . . .
MainMenu M or m Return to the Main Menu screen.
Exit E or e Terminate the async terminal session.
New N or n Enter new data.
Delete L or l Delete data.
Save S or s Save information.
Refresh R or r Update screen with current information.
ClrStats C or c Clear network performance statistics and refresh the screen, Clear status messages for one-time events.
PgUp U or u Display the previous page.
PgDn D or d Display the next page.
ResetMon R or r Reset an active Monitor of active pattern test counter to zero.
Selecting Ctrl-a allows you to switch between the two screen work areas to perform all screen functions.
To access the screen function area below the dotted line:
Example: To save the changes you have made on this screen, enter s or S (Save).

Using the ASCII Terminal Interface (ATI)
Use the Exit function key from any screen to terminate the session.
To end a session with the ASCII terminal interface:

Using the ASCII Terminal Interface (ATI)
This page intentionally left blank.

Entering Device and System Information
Use the Device Name screen to determine the name that will be displayed at the top of all ATI screens, and SNMP system information that will be displayed on the Identity screen. To access the Device Name screen, follow this menu selection sequence:
Main Menu →Control →Device Name
main/control/device_name PARADYNE Device Name: Model: 7112
Device Name: NE815378 Clear System Name: lllQJ98-001 Clear System Location: Bldg. A412, 2nd Floor, Left cabinet Clear System Contact: Joe Smith 800-555-5555 pager 888-555-5555 Clear
ÎÎ
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save
Fields on the Device Name screen are null until you enter values. Allowable values are any printable ASCII character except the ^ (caret).
Use the left and right arrow keys to scroll through the fields. Select Clear to reset a field to a null value.

To enter Device Name screen information:
Configuration option settings determine how the DSU/CSU operates. Use the Configuration branch of the DSU/CSU menu to display or change configuration option settings.
The DSU/CSU is shipped with factory settings in all four strap areas. You can find default information by:
Referring to Appendix A, Configuration Option Tables or Appendix B, Worksheets.
Accessing the Default Factory Configuration branch of the DSU/CSU menu.
The DSU/CSU has four sets of configuration option settings. The Current Configuration matches the Default Factory Configuration until modified and saved by the user.
Current Configuration The DSU/CSU’s active set of configuration options.
Customer Configuration 1 Use to set up and store a set of configuration options for future use.
Customer Configuration 2 Use to set up and store a second set of configuration options for future use.
Default Factory Configuration A read-only configuration area containing the factory default configuration options.
If the factory default settings do not support your network’s configuration, you can customize the configuration options for your application.
Configuring the DSU/CSU

To display the configuration options, you must first copy one configuration option set into the edit area.
To load a configuration option set into the configuration edit area:
Main Menu →Configuration (Load Configuration From)
The selected configuration option set is loaded and the Configuration Edit/Display menu screen appears.
See Appendix A for a list and explanation of the configuration options available.
When changes are made to the configuration options, the changes must be saved to take effect. The Save key and Save Configuration To screen appear when the user has an effective access level of 1. All other effective access levels have read-only permission.
To save configuration options changes:
When Exit is selected before Save, a Save Configuration screen appears requiring a Yes or No confirmation response.
If you select . . . Then the . . .
Yes Save Configuration To screen appears.
No Main Menu appears and changes are not saved.
Configuring the DSU/CSU

The DSU/CSU provides Cross Connect configuration options that allow you to do the following:
Display network DS0 channels assigned to the data port.
Allocate network DS0 channels to the data port.
Clear (unassign) all DS0 channels from the data port interface.
The DSU/CSU’s default configuration has all DS0 channels assigned to the data port.
To access the Cross Connect Assignments screen, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From → Cross Connect
main/config/cross_connect PARADYNE Device Name: Model: 7112 CROSS CONNECT ASSIGNMENTS Assign To: Network Port Rate (Kbps): 1536 Assign By: Block DS0s to Allocate: 24 N01 N02 N03 N04 N05 N06 N07 N08 P(B) N11 N12 N13 N14 N15 N16 N17 N18 P(B) P()
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
N19 N20 N21 N22 N23 N24 N25 N26 P(B)
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Ctrl–a to access these functions, ESC for previous menu MainMenu Exit Save Clrassign Select: Block, ACAMI, Channel.
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Configuring the DSU/CSU

Use the Cross Connect Assignments screen to view which DS0 channels are currently assigned to the data port. Below each DS0 channel you will see either “Available” or “P”. DS0s with a “P” designation are assigned to the data port. DS0s marked “Available” are unused (unassigned).
Cross Connect Assignments may also be displayed by accessing the Cross Connect Status screen under the Status branch of the Main Menu.
By using the block or ACAMI (Alternate Channel Alternate Mark Inversion) assignment method, you can assign a data port to a block of contiguous DS0 channels on the network interface.
The block assignment method allows a block of contiguous channels to be assigned by specifying the number of DS0’s to allocate and an initial DS0 channel (the first DS0 channel in a block of DS0 channels). The number of channels assigned is determined by the port rate. These channels are automatically assigned to the destination network interface when the initial DS0 channel is selected.
The ACAMI assignment method also allows a block of contiguous channels to be assigned. However, with ACAMI, the number of channels assigned is twice the number needed for the port rate. This is because with ACAMI, every alternate DS0 channel (starting with the n+1 DS0 channel), does not carry data from the port, but instead always transmits and receives all ones.
To assign data ports by the block or ACAMI method:
Main Menu →Configuration →Load Configuration From → Cross Connect
Configuring the DSU/CSU

This channel method allows you to select the individual DS0 channels to allocate to the data port. The data port rate is automatically determined based on the number of channels selected. The DS0s do not need to be contiguous.
To assign the data port by the individual channel method:
Main Menu →Configuration →Load Configuration From → Cross Connect
You can clear (deallocate) all the DS0 channels currently allocated to network interface.
To clear DS0 channel allocation:
Main Menu →Configuration →Load Configuration From → Cross Connect
Configuring the DSU/CSU

Overview
The DSU/CSU provides several methods of security by limiting user access to the ATI through option settings. Refer to ATI Access on page 4-4.
Enable the Login Required option to require a Login ID for the:
Limit the access:
— Port Access Level option of 1, 2, or 3 for the Terminal port
— Session Access Level option of 1, 2, or 3 for the Telnet Session
Disable the access:
— Telnet Session option
— Facility Data Link (FDL) option
— Ethernet Port Use option
SNMP security is handled through Community Names with access levels and IP address validation. Refer to Controlling SNMP Access on page 4-6.
— Terminal Port · — Telnet Session

Logins apply to Terminal port and Telnet access to the ATI. Six login ID/password combinations are available. Each Login ID and Password must be unique and include an access level.
For additional information regarding the ATI access using the Login Required option, refer to ATI Access on page 4-4.
To create a login record:
Main Menu →Control →Administer Logins
On the Administer Logins screen, for the . . . Enter . . .
Login ID 1 to 10 ASCII printable characters
Password 1 to 10 ASCII printable characters
Access Level Level 1, Level 2, or Level 3
Assign at least one Level 1 Access Level. Full access is necessary to make configuration option changes and administer logins.
— New to add another login record
— MainMenu to go to the Main Menu
— Exit to end the ATI session
Security

Procedure
To delete a login record:
Main Menu →Control →Administer Logins
When the deletion is complete, Command Complete appears at the bottom of the screen. The number of login pages/records reflects one less record, and the record following the deleted record appears.
Misconfiguring the access unit could render the user interface inaccessible, leaving it in a state where a session cannot be started via the COM port or a Telnet session. If this occurs, access unit connectivity can be restored via a directly connected terminal.
Two methods can be used to restore access to the user interface:
Reset COM Port – Allows you to reset the configuration options related to COM port usage. This also causes a device reset, where the access unit performs a Device Self-Test. No security-related configuration options are changed.
Reload Factory Defaults – Allows you to reload the Default Factory Configuration, resetting all of the configuration and control settings which causes the current configuration to be destroyed and a device reset. This method is also useful when the user’s password(s) have been forgotten.
To reset COM port settings:
Security

If entering yes to prompt . . . Then . . .
Reset COM Port usage Port Type is set to Terminal
Data Rate (kbps) is set to 9.6
Character Length is set to 8
Stop Bits is set to 1
Parity is set to None
External Device Commands is set to Disable
Reload Factory Defaults All factory-loaded configuration and control settings contained in the Default Factory Configuration configuration area are loaded.
If no (or n) is entered, or if no selection is made within 30 seconds, the access unit returns to the condition or operation it was in when the system reset was initiated, with the COM port rate returning to its configured rate.
The access unit resets itself, going through a Device Self-Test. Connectivity is restored and the Main Menu screen appears.
Access to the ATI is available through either the Terminal port or a Telnet session.
Access to the ATI through the Terminal port can be limited. Refer to Table A-6, Terminal Port Options, to:
Enable Login Required.
Assign a Port Access Level of 1, 2, or 3.
The ATI can be accessed remotely through a Telnet Session via either the Ethernet port or the FDL. The DSU/CSU provides several methods for limiting access to the ATI through a Telnet session.
Refer to Table A-7, Telnet Session Options, to:
— Enable Login Required.
— Assign a Telnet Session Access Level of 1, 2, or 3.
— Disable Telnet access completely.
To prevent the 10BaseT port and FDL from supporting a Telnet session:
— Set the Ethernet Port Use option to Disable. Refer to Table A-5, Ethernet
Port Options.
— Disable the FDL. Refer to Table A-2, Network Interface Options.
Preventing access to the ATI by setting the FDL or Ethernet Port Use options to Disable also inhibits SNMP management over those interfaces.
Security

The ATI effective access level (Table 4-1) is the more restrictive of:
Port/Session access level, or
The Access level associated with the Login ID.
For example, if a login ID is created with an Access Level 1 and the Terminal Port is set for a Port Access Level of 2, the effective access level to the ATI is 2.
Effective Access Level 1
Effective Access Level 2
Effective Access Level 3
ATI Access to Menu Functions
Status Full Access Full Access Read-Only
Test Full Access Full Access No Access
Configuration Full Access Read-Only Read-Only
Control Full Access No Access No Access
When user access to the ATI is attempted through the Terminal port or a Telnet session, the ATI response is based on the Login Required option and the availability of the ATI. Table 4-2 describes how the system responds to various ATI access conditions.
If access to the ATI is through the . . . Then . . . What to do now?
Terminal port with Security disabled with the Login Required option set to Disable (See Table A-6)
The Main Menu screen appears.
Select a menu option to begin your session.
Terminal port with Security enabled with the Login Required option set to Enable (See Table A 6)
If Invalid Password appears, re-enter the password. After three tries with an invalid password, contact the system administrator. (See Table A-6)
You are prompted for a login ID and password.
The Main Menu screen appears if the login ID is not configured yet.
Select a menu option to begin your session.
Security

If access to the ATI is through the . . . What to do now? Then . . .
Terminal port and the ATI is already in use with a Telnet session
User Interface Already In Use message appears with the active user’s IP address and Login ID.
Try again later.
When the ATI is available, the message User Interface Idle appears. Press Enter for the Main Menu.
Telnet session and the ATI is currently in use
Connection Failed message appears. The DSU/CSU allows only one ATI session.
Try again later.
There are three methods for limiting SNMP access.
Disable the SNMP management option.
Assign SNMP community names and access levels. The DSU/CSU supports SNMP Version 1, which provides limited security through the use of community names.
Limit SNMP access through validation of the IP address of each allowed SNMP manager.
The DSU/CSU can be managed by an SNMP manager supporting the SNMP protocol. The community name must be supplied by an external SNMP manager accessing an object in the MIB.
To define SNMP community names, follow this menu selection sequence:
Main Menu →Configuration →(Load Configuration From) → SNMP →General SNMP Management
Refer to Table A-8, General SNMP Management Options, to:
Enable SNMP Management.
Assign the SNMP community names of the SNMP Managers that are allowed to access the DSU/CSU’s Management Information Base (MIB).
Specify read or read-write access for each SNMP community name.
Security

The DSU/CSU provides an additional level of security through validation of the IP addresses.
The SNMP Management option must be enabled. To control SNMP access with IP addresses, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From → SNMP→SNMP NMS Security Options
Refer to Table A-9, SNMP NMS Security Options. The SNMP access can be limited by:
Enabling NMS IP address validation to perform validation checks on the IP address of an SNMP management system attempting to access the DSU/CSU.
Specifying read or read-write access for each NMS authorized to access the unit.
Security

This page intentionally left blank.
Security

IP Addressing
There are three IP addressing strategies to provide SNMP NMS connectivity.
Local addressing only
Extending subnet for FDL
Unique subnet for the FDL
Review the following information before selecting an IP addressing scheme.
Assign an IP address for the 10BaseT port and FDL management interfaces.
Set the default gateway address. This is a default route for all destinations not on the LAN. The gateway should be a router on the LAN with routes to the rest of the network
Each DSU/CSU routing table supports a maximum of 20 routes.
— A subnet route is automatically added for the 10BaseT port
— A Host route is automatically added for the FDL link using RIP
Any legal host address is allowed for a given subnet.

Management of IP addressing is based on individual IP addresses assigned to each interface. The IP interfaces for the unit are:
Ethernet port – See Table A-5, Ethernet Port Options.
FDL – See Table A-2, Network Interface Options.
Do not assign IP addresses without the assistance of the network manager or individuals responsible for determining the IP addressing scheme for your organization.
The following examples apply to IP (SNMP) management traffic only. The subnet mask shown for these examples is 255.255.255.000.
In the following example, the DSU/CSUs do not use the FDL for management communications. This can be the result of using Fractional T1 service or Frame Relay Service. In this example both DSU/CSUs:
Only receive management data through the 10BaseT port connection.
Do not route the data between themselves. Routers route the management data for the connected DSU/CSUs using the user data path between the routers.
The following illustration shows each DSU/CSU with its own IP address on the LAN subnet.
Subnet 135.18.1.0 Subnet 135.18.5.0

135.18.4.2
Subnet 135.18.4.0
IP Addressing · 98 -15700-01

In this example:
DSU/CSU A is connected to the NMS on LAN A through the 10BaseT port.
DSU/CSU A is connected to DSU/CSU B through the FDL.
DSU/CSU B is addressed through the FDL as if it existed on LAN A.
DSU/CSU A forwards all data to DSU/CSU B using Proxy ARP.
A proprietary RIP is used to learn the IP addresses of the remote FDL interfaces. It can take up to 5 minutes for the RIP protocol to exchange addresses once the FDL is active.
Subnet 140.20.10.0 Subnet 135.18.5.0

140.20.10.1
B
LAN A LAN B
IP Addressing · 97-15699-01

In this example:
DSU/CSU A is connected to the NMS on LAN A through the 10BaseT port.
DSU/CSU A is connected to DSU/CSU B through the FDL.
DSU/CSU A and DSU/CSU B create their own unique Subnet (LAN C).
Interconnected DSU/CSUs automatically pass routing information between each other using a proprietary protocol. However, a static route to subnet 138.20.18.2 must be set in the routing table of the NMS Host or Router.
Subnet 140.20.10.0 Subnet 135.18.5.0

140.20.10.1
140.20.10.2
7110 or 7112 DSU/CSU
LAN A LAN C LAN B
IP Addressing · 97-15698-01

After selecting an IP scheme, assign an address to the DSU/CSUs.
If using the . . . Then assign the . . .
10BaseT port as a management interface 10BaseT port IP address and subnet mask. Refer to Table A-5, Ethernet Port Options.
FDL IP address and subnet mask. Refer to Table A-2, Network Interface Options.
The DSU/CSU can validate the IP address of an NMS that attempts to access it. Refer to Table A-9, SNMP NMS Security Options.
IP Addressing

This page intentionally left blank.
IP Addressing

What to Monitor
This chapter presents information on how to access and monitor DSU/CSU status and performance statistics on the T1 network. You can monitor DSU/CSU operations by monitoring:
LEDs on the Status screen or the DSU/CSU’s front panel
System and Test Status screens
Highest priority Health and Status message on the last line of all screens
Cross Connect Status screen
Network Interface Status screen
Network Performance Statistics screen
Network Management System via SNMP MIB objects
SNMP traps and other information reported by your NMS via SNMP MIB objects

Table 6-1 shows the available indicators of alarm conditions on the network interface and the User Data port.
Status Screen
Network LED
Alarm Condition
Loss of Signal (LOS) Y SIG
Out of Frame (OOF) Y OOF
Alarm Indication Signal (AIS) Y ALARM
Excessive Error Rate (EER) Y EER
The DSU/CSU LEDs can be viewed on the Display LEDs Status screen. This ATI status screen is available locally and remotely.
The 12 LEDs are organized in three groups:
System LEDs display the status of the unit.
Network LEDs provide the status of the network interface.
Port LEDs display the activity on the user data (DTE) port.
To view the LED status screen, follow this menu selection sequence:
Main Menu →Status →Display LEDs
SYSTEM NETWORK PORT
OK FAIL TEST SIG OOF ALARM EER TXD RXD RTS CTS DTR
ÎÎ
Î
ÎÎ
ESC for previous menu MainMenu Exit Refresh
When viewed via the ATI, the status display screen is updated approximately every 5 seconds. Use Refresh to obtain a current status of all LEDs.
Monitoring the DSU/CSU · Yellow Y ALARM ·

OK: ON – DSU/CSU is operational. OFF – DSU/CSU is performing a power-up self-test, has detected a
system failure, or there is no power.
is performing a power-up self-test. Refer to Troubleshooting in Chapter 8.
or from the network. Includes power-up self-test.

Monitoring the DSU/CSU

SIG – Network Signal ON – A recoverable signal is present on the
network interface. OFF – The network signal cannot be recovered. A
Loss of Signal condition exists.
on the network interface. Refer to Table 6-2, Health and Status Messages.
condition on the received network signal. Refer to Troubleshooting in Chapter 8.
exceeded on the network interface. Refer to Table 6-2, Health and Status Messages.
Monitoring the DSU/CSU

TXD – Transmitted Data: ON – Receiving a 0 from the DTE. OFF – Receiving a 1 from the DTE.
RXD – Received Data: ON – Sending a 0 to the DTE. OFF – Sending a 1 to the DTE.
indicate readiness to transmit data.
signal to indicate to the DTE that it can start sending data.
indicate readiness for operation.
Monitoring the DSU/CSU

The status screens appear with the cursor in the function area below the dotted line. To update the information displayed, select Refresh and press Enter.
The System and Test Status screen provides a Clear command. Select Clear and press Enter to clear status messages for one-time events.
Statistics screens provide a ClrStats command. Select ClrStats and press Enter to clear all statistics and refresh the screen. ClrStats is not available for an Access level of 3.
To view System and Test Status information, follow this menu selection sequence:
Main Menu →Status →System and Test Status
The System and Test Status screen has three sections:
Health and Status – Displays messages in priority order (highest to lowest). Refer to Table 6-2, Health and Status Messages.
Self-Test Results – Results of the Diagnostic test run on the device itself. Refer to Table 6-3, Self-Test Results Messages.
Test Status – Currently active tests. Refer to Table 6-4, Test Status Messages.
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
SYSTEM AND TEST STATUS
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
HEALTH AND STATUS SELF-TEST RESULTS TEST STATUS –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Loss of Signal CPU Fail No Test Active Out of Frame Device Fail Line Loopback Active Alarm Indication Signal B8ZS/LOS Fail Payload Loopback Active Excessive Error Rate Network T1 Fail Repeater Loopback Active Yellow Alarm Alarm Fail Data Channel Loopback Active Primary Clock Failed Memory Fail Data Terminal Loopback Active FDL Link Down DSU/CSU Port Fail Ptrn Test Active, Network Device Fail yyyyyyyy Failure xxxxxxxx Mon Ptrn Test Active, Network User Data Port Down Passed Ptrn Test Active, Port Ethernet Port Down Mon Ptrn Test Active, Port System Operational Lamp Test Active ESC for previous menu MainMenu Exit Refresh Clear
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Monitoring the DSU/CSU

The following messages appear in the first column of the System and Test Status screen. The highest priority Health and Status message also appears on all ATI screens on the bottom right.
Message What Message Indicates What To Do
Loss Of Signal No signal is being received. Local DSU/CSU network problem. An LOS condition (175 consecutive zeros) has been detected on the network interface.
Out of Frame DSU/CSU is detecting an out of frame condition. This occurs when two out of four frame synchronization bits are in error.
An Alarm Indication Signal (unframed all ones signal) is being received from the network interface.
An Excessive Error Rate condition has been detected on the network interface. The condition is cleared when the error rate falls below the threshold value.
Yellow Alarm A Yellow Alarm signal is being received from the network interface.
The primary clock has failed. Timing for the DSU/CSU is provided by the internal clock.
FDL Link Down The FDL communication between the local and remote DSU/CSU is not working.
An internal error has been detected by the operating software. yyyyyyyy indicates the 8-digit hexadecimal failure code.

Message What To Do What Message Indicates
User Data Port Down
The DTE is not ready to transmit or receive data.
The DSU/CSU detects no electrical activity on the 10BaseT port.
The unit is functioning properly and there are no status messages to display.
No action required.
The results of the last power-up or reset self-test appear in the middle column of the System and Test Status screen.
Message What Message Indicates What To Do
CPU Fail The CPU failed internal testing. 1. Reset the unit and try again.
Device Fail One or more of the DSU/CSU’s integrated circuit chips has failed device-level testing.
y representative for assistance.
The DSU/CSU failed to transmit all ones or to detect a Loss of Signal.
The DSU/CSU failed to internally loop data on the network T1 circuit.
Alarm Fail The DSU/CSU failed to transmit AIS or to detect a Yellow alarm.
Memory Fail The DSU/CSU failed memory verification.
The Data Port failed self-test.
An internal failure occurred. (xxxxxxxx represents an eight-digit hexadecimal failure code for use by service personnel.)
Record the failure code and contact your service representative.
Passed No problems were found during power-up.
No action needed; no problems were found during power-up or reset.

The Test Status messages in the following table appear in the right column of the System and Test Status screen.
Test Status Message Meaning
No Test Active No tests are currently running.
Line Loopback Active The network Line Loopback test is active.
The network Payload Loopback test is active.
The network Repeater Loopback test is active.
Data Channel Loopback Active
The Data Channel Loopback test is active for the data port.
Data Terminal Loopback Active
The Data Terminal Loopback test is active for the data port.
QRSS Test Active, Network
The QRSS test pattern is being sent over the network interface.
1-in-8 Test Active, Network
The 1-in-8 test pattern is being sent over the network interface.
Mon QRSS Test Active, Network
DSU/CSU is monitoring a QRSS test pattern over the network interface.
QRSS Test Active, Port
The QRSS test pattern is being sent on the port interface.
511 Test Active, Port The 511 test pattern is being sent on the port interface.
Mon QRSS Test Active, Port
DSU/CSU is monitoring a QRSS test pattern on the port interface.
Mon 511 Test Active, Port
DSU/CSU is monitoring a 511 test pattern on the port interface.
Lamp Test Active The Lamp Test is active, causing the LEDs on the front panel to light.
Monitoring the DSU/CSU · Payload Loopback Active · Repeater Loopback Active

Use the Cross Connect Status screen to display the network interface time slots assigned to the data port. These assignments are made using the Cross Connect configuration option.
Use the following menu sequence to display network channel information.
Main Menu →Status →Cross Connect Status
The Cross Connect Status screen displays 24 two-field entries in three rows. Together, each two-field entry defines the assignment for one network interface time slot. The top field represents the time slot of the network interface. The bottom field shows whether or not the time slot is assigned to the data port.
main/status/cross_connect PARADYNE Device Name: Model: 7112
N01 N02 N03 N04 N05 N06 N07 N08 P
N17 N18 N19 N20 N21 N22 N23 N24
Î
ÎÎ
Î
ÎÎ
ESC for previous menu MainMenu Exit
The following information is available for viewing.
The Network Time Slot Fields (top) . . . Indicate the . . .
N01 to N24 Network Interface time slot (01 to 24).
The Cross Connect Status Field (bottom) . . . Indicates the time slot is . . .
blank Unassigned.
P Assigned to the data port.
Monitoring the DSU/CSU ·

Network performance statistics allow you to monitor the current status of the network operations. Performance statistics can assist you in determining the duration of specific conditions and provide a historical context for problem detection and analysis.
When the network interface is configured for ESF framing, network performance is continuously monitored and maintained in two sets of aggregate registers:
Carrier Network Interface Registers (Telco)
User Network Interface Registers (User)
These status registers collect performance data for the previous 24-hour period. Performance data is updated in 15-minute intervals. After 15 minutes, the current interval is rolled over into a set of accumulator registers that represent the previous 96 15-minute intervals for the register. An interval total of how many of the 96 registers contain valid data is also kept, as well as a 24-hour total for each accumulator register.
To view the Network Performance Statistics, follow this menu selection sequence:
Main Menu →Status →Network Performance Statistics
main/status/performance PARADYNE Device Name: Model: 7112 NETWORK PERFORMANCE STATISTICS Current Interval Timer ESF Error Events Telco=438 User=437 Telco=0 User=0 –––ES–– ––UAS–– ––SES–– ––BES–– ––CSS–– –LOFC–– –Status– Tel Usr Tel Usr Tel Usr Tel Usr Tel Usr Tel Usr (User) Current Int: 000 YL Interval 01: 000 none Interval 02: 000 none Interval 03: 000 none Interval 04: 000 none Interval 05: 000 none Interval 06: 000 none Interval 07: 000 none Worst Interval:24 24 14 09 09 18 16 44 44 Tel Tot(valid 96):00001 00000 00001 00000 00000 00000 Usr Tot(valid 96):00000 Ctrl–a to access these functions, ESC for previous menu MainMenu Exit Refresh PgDn PgUp ClrStats Select: 01, 02, 03, 04, 05, 06, 07, 08, 09...
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
NOTE:
Network performance statistics are only available for those interfaces using ESF framing. Verify that the Line Framing Format field on the Network Interface screen is set to ESF.
Monitoring the DSU/CSU

You can reset the user performance registers via the ClrStats selection on the Performance Statistics screen.
ClrStats only resets the user events. Telco events are cleared during a power-on reset.
There are four sections to the Network Performance Statistics screen:
Summary information provides the following information:
Current Interval Timer – displays the number of seconds that have elapsed in the current 15-minute interval.
ESF Error Events – displays the number of ESF frames with either a CRC error or an OOF event.
The ESF Error Event statistic is not reset every 15 minutes. If the counter reaches 65,535, it remains at this value until reset.
The Telco counter for ESF Error Events can only be cleared by a reset command from the network or a reset of the device itself.
The User counter for ESF Error Events can only be reset by selecting the ClrStats option or by resetting the device.
Network performance statistics are kept for each 15-minute interval over the past 24-hour period. There are six types of statistics recorded:
Errored Seconds (ES) – The number of errored seconds for the current interval. An errored second is any second with one or more ESF error events. The maximum is 900 seconds.
Unavailable Seconds (UAS) – The number of unavailable seconds for the current interval. An unavailable second is any one second interval when service is unavailable. (Detection occurs with 10 consecutive unavailable seconds.) The maximum is 900 seconds.
Severely Errored Seconds (SES) – The number of severely errored seconds for the current interval. A severely errored second is any second with 320 or more CRC errors, or any second with one or more OOF events. The maximum is 900 seconds.

Bursty Errored Seconds (BES) –The number of bursty errored seconds for the current interval. A bursty errored second is any second with more than one, but less than 320, CRC errors. The maximum is 900 seconds.
Controlled Slip Seconds (CSS) – The number of controlled slip seconds for the current interval.
Loss of Frame Count (LOFC) – The loss of frame count for the current interval. This is a count of the number of times that an LOF is declared. The maximum count is 255.
A Telco set and a user set are kept for each of the above statistics. The user set is a copy of the Telco set, but the user set can be cleared.
In addition to the statistics kept for the network interface, the system maintains a Status register for each interval (far-right column). The Status register shows whether or not the following events have occurred at least once within the 15-minute interval:
Y – Yellow Alarm
L – Loss of Signal
E – Excessive Error Rate
F – Frame Synchronization Bit Error
V – Line Code Violation
Every 15 minutes, the current interval’s data is rolled over into a set of accumulator registers that represent the previous 96 15-minute intervals for the register. All counts show the number of occurrences since the last reset of the counters.
When you enter the Network Performance Statistics screen, the current interval and seven most recent intervals are displayed. To display other intervals:
Use the PgUp and PgDn selections. Intervals display as a series of 7 consecutive periods (recent to old).
Tab to one of the rows in the interval table that has an underlined interval number (intervals 1, 4, and 7 when first displayed). Type the number of the interval you want to display at any of these three underlined locations. Intervals are numbered from 1 (most recent) to 96 (oldest). For example:
— Enter 10 on the top line to display intervals 10 through 17.
— Enter 10 on the middle line to display intervals 7 through 13.
— Enter 10 on the bottom line to display intervals 4 through 10.
To assist you in selecting trouble spots, a Worst Interval is also displayed. The Worst Interval is the 15-minute period that contains the largest number of seconds for either ES, UAS, SES, BES, or CSS, or the greatest Loss of Frame Count (LOFC). If more than one interval contains the same worst value, then the oldest interval is displayed.
Monitoring the DSU/CSU · none

The last two lines on the screen (above the dotted line) display the totals for each statistic over the last 24 hours, along with the number of valid intervals included in the total (up to 96).
To view the Ethernet (10BaseT) Port Status, follow this menu selection sequence:
Main Menu →Status →Ethernet Port Status
main/status/ethernet PARADYNE Device Name: Model: 7112
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ETHERNET PORT STATUS
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Port Use: Version 2 IP Address: 000.000.000.000 Subnet Mask: 000.000.000.000 Default Gateway Address: 000.000.000.000 Ethernet MAC Address: 00:00:00:00:00:00
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Frames Transmitted: 0000000000 Frames Received: 0000000000 Errored Frames: 0000000000 Excessive Collisions: 0000000000 Carrier Sense Errors: 0000000000 Deferred Transmissions: 0000000000
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ESC for previous menu MainMenu Exit Refresh ClrStats
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Table 6-5 describes the fields on the Ethernet Port Status screen.
Label What the Field Indicates
Port Use The port is enabled if 802.3 or Version 2 is displayed. The port is disabled if Disable is displayed.
IP Address The IP address of the port.
Subnet Mask The subnet mask to be used with the IP address.
Default Gateway Address The gateway to be used for packets that do not have a route.
Ethernet MAC Address The physical address of the port.
Frames Transmitted The number of frames transmitted.
Frames Received The number of frames received.
Monitoring the DSU/CSU

Label What the Field Indicates
Errored Frames The number of frames in error. This is the sum of frames with alignment errors, FCS (Frame Check Sequence) errors, and framing errors.
Excessive Collisions The number of frames for which transmission failed due to excessive collisions.
Carrier Sense Errors The number of times the carrier sense condition was lost or never asserted.
Deferred Transmissions The number of frames for which the first transmission attempt is delayed because the medium is busy.
All counts show the number of occurrences since the last reset of the counters.
To view the Management Protocol Statistics, follow this menu selection sequence:
Main Menu →Status →Management Protocol Statistics
main/status/management PARADYNE Device Name: Node A Model: 7112
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
MANAGEMENT PROTOCOL STATISTICS
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
IP TCP UDP
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Datagrams Transmitted: 0 0 0 Datagrams Received: 0 0 0 Format Errors: 0 0 0 Invalid Address: 0 – 0 Unknown Protocol: 0 – – Dropped Due To No Route: 0 – –
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ESC for previous menu MainMenu Exit Refresh ClrStats
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Monitoring the DSU/CSU

Table 6-6 describes the fields on the Management Protocol Statistics screen.
Label What the Field Indicates
Datagrams Transmitted The number of datagrams successfully transmitted at each protocol layer.
Datagrams Received The number of datagrams successfully received at each protocol layer.
Format Errors The number of protocol packets that contained errors.
Invalid Address The number of protocol packets that contained invalid addresses.
Unknown Protocol The number of datagrams that were lost due to unknown protocols.
Dropped Due To No Route
The number of datagrams that were lost due to no route.
All counts show the number of occurrences since the last reset of the counters.
Monitoring the DSU/CSU

Detecting Problems
The DSU/CSU can detect and report problem conditions and perform diagnostic tests. The DSU offers a number of indicators to alert you to possible problems:
LEDs – Refer to DSU/CSU LEDs in Chapter 6, Monitoring the DSU/CSU.
SNMP Traps – For information on traps, refer to Configuring SNMP Traps in Chapter 8, Messages and Troubleshooting.
Health and status messages and network performance statistics. Refer to Chapter 6, Monitoring the DSU/CSU.
Alarm Condition Indications.
The following table shows the available indicators of alarm conditions on the network interface and the User Data port.
SNMP Trap
Specific LED
Alarm Condition
Loss of Signal (LOS) Y1 Y Y
Out of Frame (OOF) Y1 Y Y
Alarm Indication Signal (AIS) Y1 Y N
Excessive Error Rate (EER) Y1 Y N
Yellow Y1 Y Y
FDL Link Down Y1 Y N
User Data Port Down Y1 Y Y
1 Link Up/Link Down Trap

From the Test menu, you can run network tests, data port tests, and a lamp test for the front panel LEDs.
The Test menu is limited to users with an access level of 1 or 2 (Refer to Chapter 4, Security). To access the Test menu, follow this menu selection sequence:
Main Menu →Test
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
TEST
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Network Tests Data Port Tests Lamp Test
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Ctrl-a to access these functions ESC for previous menu MainMenu Exit
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Testing · Abort Tests

Network tests require the participation of your network service provider. To access the Network Tests screen, follow this menu selection sequence:
Main Menu →Test →Network Tests
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
NETWORK TESTS
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Test Command Status Result
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Use the Command column to start or stop a test by pressing Enter. The Result column displays the test duration since the last device reset. When the Monitor QRSS test is active, ResetMon is available to reset the error counter to zero.
Selecting the Stop command on the Network Test screen or Abort Tests from the Test menu will not disrupt a network-initiated loopback.
Testing

Line Loopback (LLB) loops the received signal on the network interface back to the network without change.
To run a Line loopback:
LLB
DTE
Line Loopback cannot be started when any of the following tests are already active:
Data Channel Loopback
Send Pattern test on the network interface.
Payload Loopback (PLB) loops the received signal on the network interface back to the network. Framing CRCs and BPVs are corrected.
To run a Payload loopback:
The Start command is changed to Stop.

PLB
DTE
Payload Loopback cannot be started when any other loopback or Send Pattern test is already active on the network interface.
Repeater Loopback (RLB) loops the signal being sent from the data port back to the data port. Framing CRCs and BPVs are corrected.
To run a Repeater loopback:
DTE
Repeater Loopback cannot be started when any of the following tests are already active:
Data Terminal Loopback
Data Channel Loopback
Payload Loopback.

Remote Send Line Loopback sends the line loopback up or down code on the network interface for 10 seconds.
To run a Send Remote Line loopback:
The Send command is changed to Sending. The loopback will stop automatically after 10 seconds. You cannot stop the Remote Send Line Loopback test manually.
Remote Send Line Loopback cannot be started when any other loopback or a Send Pattern test is already active on the network interface.
The Send test sends a QRSS or 1-in-8 test pattern over the network interface. The Monitor test monitors the QRSS test pattern over the network interface.
To run a Send pattern test:
The Start command is changed to Stop.
Testing

To run a Monitor QRSS test:
The Start command is changed to Stop.
The Send and Monitor Pattern tests cannot be started when any loopback is already active on the network interface.
To access the Data Port Tests screen, follow this menu selection sequence:
Main Menu →Test →Data Port Tests
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
DATA PORT TESTS
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Test Command Status Result
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit ResetMon
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ
Testing

Data Terminal Loopback (DTLB) loops the user data back to the DTE. This loopback is located as closely as possible to the User Data Port (DTE) interface.
To run a data terminal loopback:
The Start command is changed to Stop.
DTLB
Data Terminal Loopback cannot be started when any other loopback is already active on the data port.

Data Channel Loopback (DCLB) loops the data from all network DS0 channels assigned to the port back to the network. This loopback is located as closely as possible to the User Data Port (DTE) interface.
To run a data channel loopback:
The Start command is changed to Stop.
Data Channel Loopback cannot be started when any of the following tests are active:
Line, Payload, or Repeater Loopback on the network interface
DTE Payload loopback on the data port.

The local DSU/CSU can send an ITU-T V.54 Up or Down sequence to request the start or stop of a Data Channel Loopback on a remote DSU/CSU.
The DSU/CSU can send:
In-band V.54 Up (activation) code to request the start of a Data Channel Loopback (V.54 Loop 2) at the remote DSU/CSU.
In-band V.54 Down (deactivation) code to request termination of a Remote Data Channel Loopback (V.54 Loop 2) at the remote DSU/CSU.
To send an V.54 Up or Down sequence to a remote unit:
The Start command is changed to Sending. The Up or Down sequence transmission stops automatically after 10 seconds. You cannot stop the sequence manually.
The Send V.54 Up/Down test cannot be started when any loopback or Send Pattern test is active on the network interface.
Testing

The local DSU/CSU can send an ANSI T1.403 (Annex B) Up or Down sequence to request the start or stop of a Data Channel Loopback on a remote DSU/CSU.
The DSU/CSU can send:
In-band ANSI T1.403 (Annex B) Up (activation) code to request the start of a Data Channel Loopback at the remote DSU/CSU.
In-band ANSI T1.403 (Annex B) Down (deactivation) code to request termination of a Remote Data Channel Loopback at the remote DSU/CSU.
To send an FT1 Up or Down sequence to a remote unit:
The Start command is changed to Sending. The Up or Down sequence transmission stops automatically after 10 seconds. You cannot stop the sequence manually.
The Send FT1 Up/Down test cannot be started when any loopback or Send Pattern test is active on the network interface.
This test sends a QRSS or 511 test pattern, or monitors a QRSS or 511 test pattern over the User Data Port interface.
To run a Send Pattern test:
The Start command is changed to Stop. If you want to manually stop the test, verify that the cursor is positioned at the Stop command.
Testing

To run a Monitor Pattern test:
The Start command is changed to Stop. If you want to manually stop the test, verify that the cursor is positioned at the Stop command.
The Send and Monitor Pattern tests cannot be started when any loopback is already active on the data port.
The Lamp test determines whether all LEDs are lighting properly.
During the Lamp test, all LEDs blink simultaneously every second. When you stop the Lamp test, the LEDs are restored to their normal condition.
A test initiated by the user can be ended by the user.
A Test Timeout option is available to automatically terminate a user-initiated Loopback or Pattern test (as opposed to manually terminating a test) after it has been running a specified period of time. Refer to Table A-1, System Options.
Test Timeout does not pertain to tests commanded by the:
— Network, such as the network-initiated Line and Payload Loopbacks.
— DTE, such as the DTE-initiated Data Channel Loopback.
On each test screen is a command column. Pressing Enter when the cursor is on the Stop command stops the test.
Use the Abort Tests selection from the Test menu to stop all tests running on all interfaces, with the exception of network or DTE-initiated loopbacks. Command Complete appears when all tests on all interfaces have been terminated.
Test status messages appear in the right-most column of the System and Test Status screen. See Table 6-4, Test Status Messages, in Chapter 6.
Testing

Overview
There are many messages available to assess the status of the device and contribute to problem resolutions. Refer to the following sections:
— Configuring SNMP Traps
SNMP traps are unsolicited messages sent out from the DSU/CSU automatically when the DSU/CSU detects conditions set by the user.
An SNMP trap can be automatically sent out through the FDL or the Ethernet port to the SNMP manager when the DSU/CSU detects conditions set by the user. These traps enable the SNMP manager to gauge the state of the device. Refer to Appendix D, Standards Compliance for SNMP Traps, for details of SNMP traps supported by the DSU/CSU.
To configure the DSU/CSU for SNMP traps, use the SNMP Traps Options screen to:
Enable SNMP traps.
Set the number of SNMP managers that receive SNMP traps from the DSU/CSU.
Enter an IP address and network destination for each SNMP manager specified.
Select the type of SNMP traps to be sent from the DSU/CSU.
SNMP Traps · Device Messages · Troubleshooting

To configure SNMP Traps, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From → SNMP →SNMP Traps
Refer to Table A-10, SNMP Traps Options.
The Device Messages in Table 8-1, listed in alphabetical order, may appear in the messages area at the bottom of the ATI screens.
Device Message What Message Indicates What To Do
Cannot Save – no Login IDs with Access Level 1
All of the login IDs being saved have an access level below Level 1.
Change the access level of at least one Login ID to Level 1 so that configuration changes can be made. (Levels 2 and 3 cannot make configuration changes.) Save the Login IDs.
Command Complete Action requested has successfully completed.
No action needed.
Invalid Character (x)1 A nonprintable ASCII character has been entered.
Re-enter information using valid characters.
Invalid – Data Terminal (or Channel) Initiated Loopback Active
Network-initiated loopback was in progress when another selection was made.
No action needed.
Invalid Password Login is required and an incorrect password was entered; access is denied.
Try again.
Contact your system
administrator to verify your password.
Invalid – [Test] Already Active
The [test] was already in progress when another selection was made.
Allow test to continue.
Select another test.
Stop the test.
A loopback or pattern test was in progress when Start was selected to start another test, or was active on the same or another interface when Start was selected.
Wait until other test ends and
message clears.
Abort all tests from the Test
menu screen.
Stop the test from the same
screen the test was started from.
1 x is the character not being accepted.
Messages and Troubleshooting · Invalid Test Combination

Device Message What To Do What Message Indicates
Limit of six Login IDs reached
An attempt to enter a new login ID was made, and the limit of six login/password combinations has been reached.
No Security Records to Delete
Delete was selected from the Administer Login screen, and no security records had been defined.
No action needed.
Enter a security record.
Password Matching Error – Re-enter Password
Password entered in the Re-enter Password field of the Administer Logins screen does not match what was entered in the Password field.
Try again.
Please Wait Command takes longer than 5 seconds.
Wait until message clears.
Test Active A test is running and no higher priority health and status messages exist.
Contact service provider if test
initiated by the network.
Wait until the test ends and
message clears.
Cancel all tests from the Test
screen.
Stop the test from the same
screen the test was started from.
Messages and Troubleshooting

This DSU/CSU is designed to provide you with many years of trouble-free service. If a problem occurs, however, refer to Table 8-2 for possible solutions.
Symptom Possible Cause Solutions
Alarm LED is on. One of several alarm conditions exists. Health and Status displays the alarm condition.
Refer to Table 6-2, Health and Status Messages, for recommended action.
Fail LED is on. One of several error conditions exists. Health and Status displays the alarm condition.
Refer to Table 6-2, Health and Status Messages, and Table 6-3, Self Test Results Messages, for recommended action.
Cannot access the DSU/CSU via the ATI.
The terminal is not set
up for the correct rate or data format, or the DSU/CSU is configured so it prevents access.
Telnet is not enabled
Device Fail appears on the System and Test Status screen under Self-Test results.
The DSU/CSU detects an internal hardware failure.
Select ClrStats from the status
Contact your service
representative.
No power, or the LEDs are not lit.
The power cord is not securely plugged into the wall receptacle and into the rear panel connection.
Check that the power cord is securely attached at both ends.
The wall receptacle has no power.
Check the wall receptacle power
by plugging in some equipment that is known to be working.
Check the circuit breaker.
Verify that your site is not on an
energy management program.
Power supply has failed. Replace power supply.
An LED is not lit. LED is out. Run the Lamp test. If the LED in question does not flash with the other LEDs, then contact your service representative.
Messages and Troubleshooting · menu

Symptom Solutions Possible Cause
Not receiving data. The network or data port
Check network and data port
cables are not connected (check front panel LEDs for more information).
cables.
Run Loopback tests. Refer to
Chapter 7, Testing.
A test is being executed
Stop the test or wait for the test
on the unit (check the TEST LED on the front panel).
to end.
The data port is not
Check the Cross Connect Status
assigned to the network.
screen. If the data port is not assigned to any network timeslots, use the Cross Connect Assignment screen (under the Config menu) to connect the port to the network.
The far-end device is
Make sure the far-end device is
off-line.
on.
Power-Up Self-Test fails. Only Fail LED is on after power-up.
The DSU/CSU has detected an internal hardware failure.
Select ClrStats from the status
Contact your service
representative.
Messages and Troubleshooting · menu

This page intentionally left blank.
Messages and Troubleshooting

A
Overview
The tables in this appendix summarize the configuration options accessed when you select Configuration on the Main Menu. The configuration options are arranged into groups based upon functionality.
All changes to configuration options must be saved. Refer to Saving Configuration Options in Chapter 3.
Configuration Edit/Display System Network Cross Connect Data Port Ethernet Port Terminal Port Telnet Session SNMP
MAIN MENU Status Test Configuration Control
Load Configuration From... SNMP & Communication Communication Protocol General SNMP Management SNMP NMS Security SNMP Traps
Select . . . To Access the . . . To Configure the . . .
System System Options, Table A-1 General system options
Network Network Interface Options, Table A-2 T1 network interface
Cross Connect Cross Connect Assignments, Table A-3 Cross connections between T1 DS0s and the data port
Data Port Data Port Options, Table A-4 User data on DTE port
Ethernet Port Ethernet Port Options, Table A-5 10BaseT
Terminal Port Terminal Port Options, Table A-6 Terminal Port
A-1 7112-A2-GB20-20 March 1998
97-15683

Select . . . To Configure the . . . To Access the . . .
Telnet Port Telnet Session Options, Table A-7 Telnet user interface
SNMP General SNMP Management
Management support through SNMP
Options, Table A-8
SNMP NMS Security Options,
SNMP Traps Options, Table A-10
For System Options, refer to Table A-1. To access the System Options screen, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From →System
Controls whether or not the DSU/CSU performs a self-test at power-up and after reset.
Enable – Self-test will be performed at power-up and after a reset.
Disable – Self-test is disabled. The DSU/CSU will still perform a few basic tests (such as memory and program checksum).
Allows user-initiated tests to end automatically. Recommend enabling when the unit is managed remotely through the FDL to avoid the requirement to terminate the test manually.
Enable – User-initiated loopback and pattern tests end when test duration is reached.
Disable – Tests can be terminated manually from the Network Tests screen. Refer to Running Network Tests in Chapter 7.
Number of minutes for a test to be active before automatically ending.
Test Duration (min) option appears when Test Timeout is enabled.
1 to 120 – Amount of time in minutes for a user-initiated test to run before terminating.
A-2 7112-A2-GB20-10 March 1998

For Network Interface Options, refer to Table A-2. To access the Network Interface Options screen, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From →Network
Determines the primary source for the master clock. The source will provide all the timing within the DSU/CSU as well as the clocks for all external interfaces.
Network – Master clock source is derived from the T1 network interface.
Internal – Master clock source is the DSU/CSU internal clock.
Port – Master clock source is derived from the data port.
Specifies the framing format to be used on the network interface.
ESF – Selects the Extended Superframe format.
D4 – Selects the D4 framing format.
Specifies the line coding format to be used on the network interface.
B8ZS – Selects the Bipolar 8 Zero Suppression coding format.
AMI – Selects the Alternate Mark Inversion coding format.
A-3 7112-A2-GB20-20 March 1998

Specifies when bit stuffing is performed to meet the ones density requirements for data transmission on the network. You must choose the maximum number of consecutive zeros the DSU/CSU can receive before it inserts a one.
62411 – Specifies that a one is inserted in the data stream after 15 consecutive zeros or when the density of ones falls below 12.5% (complies with AT&T TR 62411).
Part68 – Specifies that a one is inserted in the data stream after 80 consecutive zeros (complies with FCC Part 68).
Disable – Disables bit stuffing so that ones density is not enforced.
in Canada must be configured to select 62411.
– To comply with USA Part 68 regulations, equipment installed in the USA
must be configured to select Part 68.
– This configuration option is only available if the network interface line
coding format is set to AMI.
Line Build Out (LBO)
Specifies the line build out (LBO) for the signal transmitted to the network.
Specifies whether Facility Data Link (FDL) is enabled. Selecting Enable allows SNMP or Telnet traffic to flow over the 4 kbps data link provided by FDL. Running SNMP or Telnet over FDL requires an end-to-end FDL connection and cannot be terminated within the network.
Enable – Enables the FDL management link for SNMP or Telnet.
Disable – Disables the FDL management link.
ESF.
– If the local DSU/CSU’s FDL is enabled, the remote DSU/CSU’s FDL
must also be enabled.
Specifies the Internet Protocol address used to access the unit via the FDL.
000.000.000.000 – 255.255.255.255 – The range for the first byte is 000 to 255, with the exception of 127. The range for the remaining three bytes is 000 to 255.
Clear – Clears the FDL IP address and sets to all zeros.
A-4 7112-A2-GB20-10 March 1998

Specifies the subnet mask used to access the unit via the FDL interface.
000.000.000.000 – 255.255.255.255 – Set the FDL interface subnet mask. The range for each byte is 000 to 255.
Clear – Clears the FDL Subnet Mask and sets to all zeros. When the subnet mask is all zeros, the device creates a default subnet mask based on the class of IP address:
– Class A defaults to 255.000.000.000 – Class B defaults to 255.255.000.000 – Class C defaults to 255.255.255.000
Network Initiated Line Loopback (LLB)
Allows initiation and termination of the LLB to be controlled by the receipt of LLB-actuate and LLB-release commands from the network (or remote DSU/CSU).
Enable – Causes the DSU/CSU to enter an LLB (if the DSU/CSU can perform an LLB in its current state) and to cause an LLB-release command to terminate the LLB.
Disable – Causes the DSU/CSU to ignore LLB-actuate and LLB-release commands (the DSU/CSU is not in compliance with ANSI T1.403 and AT&T TR 62411).
Network Initiated Payload Loopback (PLB)
Allows initiation and termination of the PLB to be controlled by the receipt of PLB-actuate and PLB-release commands from the network (or remote DSU/CSU).
Enable – Causes the DSU/CSU to enter a PLB (if the DSU/CSU can perform a PLB in its current state) and to cause a PLB-release command to terminate the PLB.
Disable – Causes the DSU/CSU to ignore PLB-actuate and PLB-release commands (the DSU/CSU is not in compliance with ANSI T1.403 and AT&T TR 54016).
in-band PLB-actuate and PLB-release codes specified by AT&T as well as the bit-oriented FDL messages specified by ANSI.
– This configuration option is only available if the network interface
framing is set to ESF.
A-5 7112-A2-GB20-20 March 1998
Configuration Option Tables · FDL Subnet Mask

ANSI Performance Report Messages
Specifies whether ANSI T1.403 compliant performance report messages (PRMs) are generated.
Disable – Prevents the DSU/CSU from generating ANSI PRMs.
Enable – Generates and sends ANSI PRMs over the FDL every second.
Uniquely identifies the DS1 circuit.
ASCII Text – Enter a maximum of 15 characters.
Clear – Clears the field.
A-6 7112-A2-GB20-10 March 1998
Configuration Option Tables · Circuit Identifier

For Cross Connect Assignment Options, refer to Table A-3. To access the Cross Connect Assignments screen, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From → Cross Connect
Specifies the method for assigning the synchronous data port’s DS0 channels to the network interface.
Block – Allocates DS0 channels by the block method.
ACAMI – Allocates DS0 channels by the Alternate Channel Alternate Mark Inversion method. The difference between block and ACAMI is that the number of channels allocated with ACAMI is double the number needed for the port rate. With ACAMI, every alternate DS0 channel does not carry data from the port but always transmits and receives all ones.
Channel – Allocates DS0 channels by the individual channel method.
Synchronous Data Port Assignments
P(x), P(x), ..., P(x) Default Setting: P(B) (all DS0’s assigned to data port)
Designates the assignment of DS0 channels connected to the synchronous data port.
There are three rows in the assignment table. In each row, the top line displays channels (DS0’s) for the network interface. The bottom line displays what whether that DS0 is available (unassigned) or connected to the synchronous data port. If connected to the synchronous data port, the value of P(x) specifies the assignment method used for the connection:
P(A) This DS0 channel is allocated to the synchronous data port using the ACAMI method.
P(B) This DS0 channel is allocated to the synchronous data port using the Block method.
P(C) This DS0 channel is allocated to the synchronous data port using Channel method.
A-7 7112-A2-GB20-20 March 1998
Configuration Option Tables · Assign By · Value Meaning

For Data Port Options, refer to Table A-4. To access the Data Port Options screen, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From →Data Port
Allows selection of the base rate for the synchronous data port. The data rate for the port is a multiple (from 1 to 24) of the base rate specified with this configuration option.
Nx64 – Sets the base rate for this port to 64 kbps. The data rate is Nx64 kbps, where N is a number from 1 to 24.
Nx56 – Sets the base rate for this port to 56 kbps. The data rate is Nx56 kbps, where N is a number from 1 to 24.
Specifies whether the clock supplied by the DSU/CSU on the TXC interchange circuit DB (CCITT 114) is phase inverted with respect to the Transmitted Data interchange circuit BA (CCITT 103). This configuration option is useful when long cable lengths between the DSU/CSU and the DTE are causing data errors.
Disable – Indicates TXC supplied by the DSU/CSU on this port is not phase inverted.
Enable – Indicates TXC supplied by the DSU/CSU on this port is phase inverted.
Specifies whether the transmitted data for the synchronous data port is clocked using an internal clock provided by the DSU/CSU (synchronized to the clock source specified by the clock source configuration option) or an external clock provided by the DTE connected to the synchronous data port. If an external clock is used, it must be synchronized to the same clock source as the DSU/CSU.
Internal – Indicates the clock is provided internally by the DSU/CSU on the TXC interchange circuit DB (CCITT 114).
External – Indicates the clock is provided externally by the DTE on the XTXC interchange circuit DA (CCITT 113). Use this selection if the clock source is set to the data port.
A-8 7112-A2-GB20-10 March 1998

Invert Transmit and Received Data
Specifies whether the synchronous data port’s transmitted data and received data are logically inverted before being transmitted or received. This configuration option is useful for applications where HDLC data is being transported. Inverting the data ensures that the density requirements for the network interface are met.
Disable – Indicates the transmitted data and received data for this port are not inverted.
Enable – Indicates the transmitted data and received data for this port are inverted.
Send All Ones on Data Port Not Ready
Specifies the conditions on the data port that determine when valid data is not being sent from the DTE. When this condition is detected, all ones are sent to the network on the DS0 channels allocated to the synchronous data port.
Both – Monitors both DTR and RTS. If either is interrupted, all ones are sent to the network.
Disable – Disables the monitoring of interchange circuits from the DTE connected to the synchronous data port.
DTR – Monitors the DTE Ready interchange circuit CD (CCITT 108/1/2). When DTR is interrupted, all ones are sent to the network.
RTS – Monitors the Request-to-Send interchange circuit CA (CCITT 105). When RTS is interrupted, all ones are sent to the network.
Action on Network Yellow Alarm
Specifies the action taken on the synchronous data port when a Yellow Alarm is received on the network interface.
Halt – Stops the transmission of data on the data port and disables the data port when Yellow Alarms are received on the network interface. When Yellow Alarms are received, all ones are sent on the Received Data interchange circuit BB (CCITT 104). The Clear-to-Send interchange circuit CB (CCITT 106) is interrupted.
None – Makes the data port unaffected by Yellow Alarms received on the network interface.
A-9 7112-A2-GB20-20 March 1998
Configuration Option Tables

Network Init. Data Channel Loopback
Allows the initiation and termination of a Data Channel Loopback (V.54 loop 2) by the receipt of a V.54 DCLB-actuate sequence or DCLB-release sequence from the network or far-end device. The sequences may be either V.54 or FT1 (ANSI) compliant sequences.
Disable – Ignores the DCLB-actuate and DCLB-release sequences for this port.
V.54 – Enables DCLB-actuate and DCLB-release sequences that comply with the V.54 standard for ‘‘Inter-DCE signaling for point to point circuits.”
FT1 – Enables DCLB-actuate and DCLB-release sequences that comply with the ANSI T1.403, Annex B standard for ‘‘In-band signaling for fractional-T1 (FT1) channel loopbacks.”
Both – Enables DCLB-actuate and DCLB-release sequences that comply with either the ANSI or V.54 standard. The type of actuate and release sequences do not have to match.
Port (DTE) Initiated Loopbacks
Allows the initiation and termination of a local Data Terminal Loopback (DTLB) or remote Data Channel Loopback (DCLB) by the DTE connected to the synchronous data port. (DTLB is equivalent to a V.54 loop 3, and DCLB is equivalent to a V.54 loop 2.) Control of these loopbacks is through the DTE interchange circuits as specified by the V.54 standard.
Disable – Disables control of local DTLBs and remote DCLBs by the DTE connected to this port.
DTLB – Gives control of the local DTLBs for this port to the DTE attached to this port. This loopback is controlled by the Local Loopback interchange circuit LL (CCITT 141).
DCLB – Gives control of the remote DCLBs for the far-end port connected to this port to the DTE attached to this port. This loopback is controlled by the Remote Loopback interchange circuit RL (CCITT 140). The far-end equipment must support in-band V.54 loopbacks.
Both – Gives control of local DTLBs and remote DCLBs to the DTE connected to this port.
A-10 7112-A2-GB20-10 March 1998
Configuration Option Tables

For Ethernet Port Options, refer to Table A-5. To access the Ethernet Port Options screen, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From → Edit →Ethernet Port
The Ethernet port provides a choice of functions.
802.3 – Configures the DSU/CSU to use IEEE 802.3 format.
Version 2 – Configures the system to use Ethernet Version 2 format.
Disable – Data received on this port is ignored.
No other fields in this table will appear when set to Disable.
Specifies the IP (Internet Protocol) address used to identify the Ethernet port. Each three-digit decimal number represents a byte.
000.000.000.000 – 255.255.255.255 – Enter an address. The range for the first byte is 000 to 255, with the exception of 127. The range for the remaining three bytes is 000 to 255.
Clear – Clears the IP Address and sets to all zeros.
Specifies the subnet mask needed to access the Ethernet port.
000.000.000.000 – 255.255.255.255 – Set the Ethernet port subnet mask. The range for each byte is 000 to 255.
Clear – Clears the subnet mask and sets to all zeros. When the subnet mask is all zeros, the device creates a default subnet mask based on the class of IP address:
– Class A defaults to 255.000.000.000 – Class B defaults to 255.255.000.000 – Class C defaults to 255.255.255.000
A-11 7112-A2-GB20-20 March 1998

Specifies the IP address of the default gateway to be used for packets that do not have a route.
000.000.000.000 – 255.255.255.255 – Enter an address. The range for the first byte is 000 to 255, with the exception of 127. The range for the remaining three bytes is 000 to 255. If the address is 000.000.000.000, all packets without a route are discarded.
Clear – Clears the Default Gateway Address and sets to all zeros.
For Terminal Port Options, refer to Table A-6. To access the Terminal Port Options screen, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From → User Interface →Terminal Port
Data rate in kbps on the Terminal port.
2.4 to 38.4 – Selects a Terminal port data rate from 2.4 to 38.4 kbps.
Specifies the number of bits needed to represent one character, including the parity bit.
7 or 8 – Sets the bits per character.
Specifies Parity for the Terminal port.
None – Provides no parity.
Even – Parity is even.
Odd – Parity is odd.
A-12 7112-A2-GB20-10 March 1998

Provides the number of stop bits for the Terminal port.
1 or 2 – Selects the number of stop bits.
Specifies monitoring of the Data Terminal Ready (DTR) control lead.
Enable – Standard operation of the DTR control lead.
Disable – DTR is ignored. Some external device connections may require this setting.
Used to secure access to the ATI through the Terminal port. Login IDs are created with a password and access level.
Enable – Security is enabled. When ATI access is attempted through the Terminal port, a screen appears that requires a Login ID and password.
Disable – Main menu appears with no Login required.
The Terminal port access level is interrelated with the access level of the Login ID.
Level 1 – This is the highest access level. If Login Required is disabled, the Terminal port access is level 1. If Login Required is enabled, the effective level is the Login ID access level.
Level 2 – This access level overrides a Login ID with an access level 1. If a Login ID has an access level of 1 or 2, the effective access level is 2. If a Login ID has an access level of 3, the effective access level is 3.
Level 3 – This access level of the port is 3, regardless of the access level of the Login ID (overriding a Login ID with an access level of 1 or 2).
A-13 7112-A2-GB20-20 March 1998

Provides automatic logoff of an ATI session through the Terminal Port. When the session is closed, User Interface Idle appears on the screen and the unit toggles the Terminal port DSR lead.
Enable – The ATI session terminates automatically after the Disconnect Time set in the next option. When the session was occurring over an external modem connected to the Terminal port, the modem will interpret the DSR toggle as DTR being dropped and disconnect.
Disable – An ATI session through the Terminal port will remain active indefinitely.
Number of minutes of inactivity before the ATI session terminates automatically. Timeout is based on no keyboard activity.
Disconnect Time(minutes) option appears when Inactivity Timeout is enabled.
1 to 60 – The ATI user session is closed after the selected number of minutes.
To access the Telnet Session Options screen, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From → User Interface →Telnet Session
Specifies if the DSU/CSU will respond to a Telnet session request from a Telnet client on an interconnected IP network.
Enable – Allows Telnet sessions between the unit and a Telnet client.
Disable – No Telnet sessions allowed.
A-14 7112-A2-GB20-10 March 1998

Used to secure access to the ATI through a Telnet session. Login IDs are created with a password and access level. Refer to Creating a Login in Chapter 4.
Enable – Security is enabled. When access is attempted via Telnet, the user is prompted for a Login ID and password.
Disable – No Login required for a Telnet session.
The Telnet session access level is interrelated with the access level of the Login ID.
Level 1 – This is the highest access level. Access level is determined by the Login ID. If Login Required is disabled, the session access is level 1.
Level 2 – This access level overrides a Login ID with an access level 1. If a Login ID has an access level of 3, the effective access level is 3.
Level 3 – This access level provides the effective access level and overrides the access level of a Login ID.
Provides automatic logoff of a Telnet session.
Enable – The Telnet session terminates automatically after the Disconnect Time set in the next option.
Disable – A Telnet session will not be closed due to inactivity.
Number of minutes of inactivity before a Telnet session terminates automatically. Timeout is based on no keyboard activity.
Disconnect Time (minutes) option appears when Inactivity Timeout is enabled.
1 to 60 – The Telnet session is closed after the selected number of minutes.
A-15 7112-A2-GB20-20 March 1998

The SNMP Menu includes the following:
General SNMP Management Options, Table A-8
SNMP NMS Security Options, Table A-9
SNMP Traps Options, Table A-10
To access the General SNMP Management Options screen, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From→ SNMP →General SNMP Management
Specifies if the DSU/CSU can be managed by an SNMP NMS or send out SNMP traps.
Enable – Enables SNMP management.
Disable – DSU/CSU does not respond to SNMP messages or send out SNMP traps.
Community Name of external SNMP Managers allowed access to the DSU/CSU’s MIB. This community name must be supplied by an external SNMP manager attempting to access a MIB object. Level of access is set in the next option, Name 1 Access.
ASCII Text – Enter a maximum of 255 ASCII printable characters.
Clear – Clears the Community Name 1 field.
Set the access level for the Community Name 1 created in the previous option.
Read – Allows a read-only access (i.e., SNMP Get) to accessible MIB objects.
Read/Write – Allows both an SNMP Get and Set to MIB objects. Write access allowed to all MIB objects specified as read-write in the MIB RFC.
A-16 7112-A2-GB20-10 March 1998

Community Name of external SNMP Managers allowed access to the DSU/CSU’s MIB. This community name must be supplied by an external SNMP manager attempting to access a MIB object. Level of access is set in the next option, Name 2 Access.
ASCII Text – Enter a maximum of 255 ASCII printable characters.
Clear – Clears the Community Name 2 field.
Set the access level for the Community Name 2 created in the previous option.
Read – Allows a read-only access (i.e., SNMP Get) to accessible MIB objects.
Read/Write – Allows both an SNMP Get and Set to MIB objects. Write access allowed to all MIB objects specified as read-write in the MIB RFC.
To access the SNMP NMS Security Options screen, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From →Edit → SNMP →SNMP NMS Security
Determines if security checks are performed on the IP address of any SNMP management system that attempts to access the node.
Enable – Performs security checking. Allows access only if the sending manager’s IP address has been entered on the NMS IP address list below.
Disable – No security checking of incoming SNMP messages.
Set the number of SNMP managers that are authorized to send SNMP messages. The IP address of each SNMP management system must be entered in the next option.
1 to 10 – Specifies the number of SNMP managers allowed to send SNMP messages.
A-17 7112-A2-GB20-20 March 1998

NMS n IP Address
Enter an IP address for each of the managers set in the previous option. n is the number of the manager (1 to 10). Use the next option to establish the security level for each SNMP manager.
000.000.000.000 – 255.255.255.255 – Sets the NMS IP address. The range for the first byte is 001 to 255, with the exception of 127. The range for the remaining three bytes is 000 to 255.
Clear – Clears the IP address and sets to all zeros.
Set the access level for each IP address created in the previous option.
Read – Allows a read-only access (SNMP Get) to accessible MIB objects.
Read/Write – Allows both an SNMP Get and Set to MIB objects. Write access allowed to all MIB objects specified as read-write in the MIB RFC. This access level is overridden by the Community Name’s access level for the SNMP Manager, if the Community Name access level is Read.
A-18 7112-A2-GB20-10 March 1998
Configuration Option Tables · Access Level

To access the SNMP Traps Options screen, follow this menu selection sequence:
Main Menu →Configuration →Load Configuration From →Edit → SNMP & Communication →SNMP Traps
Controls the generation of SNMP trap messages. The options for addresses and types of traps are located in this table.
SNMP Management must be enabled in Table A-8.
Enable – SNMP trap messages are sent out to SNMP managers.
If the destination is the Management port and an external device is attached to the
Management port, the messages are sent immediately if there is an active connection. The destination is set with the Trap Manager Destination option.
Disable – No SNMP trap messages are sent out.
Number of Trap Managers
Sets the number of SNMP management systems that will receive SNMP traps.
1 to 6 – Number of trap managers. An NMS IP address is required for each manager.
Trap Manager n IP Address
Specifies the Internet Protocol address used to identify each SNMP trap manager. n represents the number of the manager (from 1 to 6).
000.000.000.000 – 255.255.255.255 – Enter an address for each SNMP trap manager. The range for the first byte is 000 to 255, with the exception of 127. The range for the remaining three bytes is 000 to 255.
Clear – Clears the IP address and sets to all zeros.
Trap Manager n Destination
Provides the network destination path of each trap manager. n is the number of the manager (from 1 to 6).
None – No network destination is defined.
Ethernet – The Ethernet port is the network destination.
FDL – The Facility Data Link Channel is the default network destination.
FDL Management Link option must be enabled in Table A-2.
A-19 7112-A2-GB20-20 March 1998
Configuration Option Tables · SNMP Traps

Determines which SNMP traps are sent to each trap manager.
Disable – No general trap messages are sent.
Warm – Sends trap message for “warmStart”.
AuthFail – Sends trap message for “authenticationFailure”.
Both – Sends both trap messages.
This option is used to determine if SNMP traps are generated for enterprise-specific events.
Enable – SNMP traps are generated for enterprise-specific events.
Disable – No enterprise-specific event traps are sent.
This option is used to determine if SNMP traps are generated for link up and link down for one of the communication interfaces.
Disable – No linkUp or linkDown SNMP traps are generated.
Up – A linkUp trap is generated when the DSU/CSU recognizes that one of the communication interfaces is operational.
Down – A linkDown trap is generated when the DSU/CSU recognizes a failure in one of the communication interfaces.
Both – Sends trap messages for detection of both linkUp and linkDown.
This option determines if the SNMP linkUp, SNMP linkDown, and interface-related enterprise-specific traps are generated for the Network T Interface and/or User Data (DTE) port.
Network – SNMP trap messages are generated for the network T1 interface.
Port – SNMP trap messages are generated for the User Data (DTE) port.
Both – SNMP trap messages are generated on both the network T1 interface and the User Date (DTE) port.
A-20 7112-A2-GB20-10 March 1998

B
Overview
The worksheets in this appendix summarize the configuration options accessed when you select Configuration on the Main Menu. The possible menu selections are displayed with the default settings and the possible settings.
Configuration Option Settings (default in Bold)
Self Test Enable, Disable
Test Timeout Enable, Disable
Test Duration (min) 1–120 [10]
B-1 7112-A2-GB20-20 March 1998

Configuration Option Settings (default in Bold)
Primary Clock Source Network, Internal, Port
Line Framing Format ESF, D4
Line Coding Format B8ZS, AMI
Bit Stuffing 62411, Part68, Disable
Line Build Out (LBO) 0.0, –7.5, –15, –22.5
FDL Management Link Enable, Disable
FDL IP Address 000.000.000.000 – 255.255.255.255, clear
FDL Subnet Mask 000.000.000.000 – 255.255.255.255, clear – Class A defaults to 255.000.000.000 – Class B defaults to 255.255.000.000 – Class C defaults to 255.255.255.000
Network Initiated Line Loopback (LLB) Enable, Disable
Network Initiated Payload Loopback (PLB) Enable, Disable
ANSI Performance Report Messages Disable, Enable
Configuration Option Settings (default in Bold)
Assign By Block, ACAMI, Channel
Synchronous Data Port Assignments P(B)
The default is all DSOs assigned to the data port
... data port.
B-2 7112-A2-GB20-10 March 1998
Worksheets · Cross Identifier <Blank>


The default is that all DS0s are assigned to the data port

Send All Ones on Data Port Not Ready Disable, DTR, RTS, Both
B-3 7112-A2-GB20-20 March 1998
Worksheets


Network Init. Data Channel Loopback Disable, V.54, FT1, Both


Data Rate (Kbps) 2.4, 4.8, 9.6, 14.4, 19.2, 28.8, 38.4
Port Access Level Level 1, Level 2, Level 3

Session Access Level Level 1, Level 2, Level 3
B-4 7112-A2-GB20-10 March 1998
Worksheets

Configuration Option Settings (default in Bold)
SNMP Management Enable, Disable
Community Name 1 ASCII Text, Public
Name 1 Access Read, Read/Write
Community Name 2 ASCII Text
Name 2 Access Read, Read/Write
NMS IP Validation Enable, Disable
Number of Managers 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
NMS n IP Address 000.000.000.000 – 255.255.255.255 (first byte cannot be 127)
Access Level Read, Read/Write
SNMP Traps Enable, Disable
Number of Trap Managers 1, 2, 3, 4, 5, 6
Trap Manager n IP Address 000.000.000.000 – 255.255.255.255
Trap Manager n Destination None, Ethernet, FDL
General Traps Disable, Warm, AuthFail, Both
Enterprise Specific Traps Enable, Disable
Link Traps Disable, Up, Down, Both
Link Trap Interfaces Network, Port, Both
B-5 7112-A2-GB20-20 March 1998

This page intentionally left blank.
B-6 7112-A2-GB20-10 March 1998
Worksheets

Overview
The MIB descriptions listed here provide clarification for the MIB objects when it is not clear how the object definition in the applicable RFC is related to the unit. Otherwise, the MIB object is supported as documented in the RFC. The 7112 SNMP DSU/CSU supports:
MIB II (RFC 1213 and RFC 1573)
Ethernet-like MIB (RFC 1643)
RS-232-Like MIB (RFC 1659)
Generic Interface Extension MIB (RFC 1229)
The unit supports the following MIB II object groups as defined in RFC 1213 and RFC 1573:
System Group Objects, Table C-1
Interfaces Group Objects – Supported for the T1 network interface, User Data (DTE) port, Terminal port, and the FDL as defined in RFC 1573, the Evolution of the Interfaces Group.
— Interfaces Group Objects, Table C-2
— Extension to Interface Table (ifXTable), Table C-3
— Interface Stack Group Objects, Table C-4
IP Group Objects, Table C-5
ICMP (Internet Control Management Protocol) Group
TCP (Transmission Control Protocol) Group
UDP (User Datagram Protocol) Group
C-1 7112-A2-GB20-20 March 1998
Enterprise MIB

Transmission Group Objects. Supported on the:
— DS1 network interface using the DS1 Enterprise MIB.
— User Data (DTE) port and Terminal port using the RS-232-like MIB.
— 10BaseT port using the Ethernet-like MIB.
The following MIB II groups are not supported:
Address Translation Group
Exterior Gateway Protocol (EGP) Group
Generic Receive Address Table
System Group objects are fully supported by the unit.
Object, OID, Access Description Setting/Contents
Provides a full name and version identification for the system’s hardware and software.
1.3.6.1.2.1.1.1 read-only
Identifies the network management subsystem.
1.3.6.1.4.1.1795.1.14.2.5.2
1.3.6.1.2.1.1.2 read-only
Identifies the length of time since last unit IPL.
Days, hours, minutes, and seconds since last IPL.
1.3.6.1.2.1.1.3 read-only
Provides the textual identification of the contact person for this managed unit.1
ASCII character string, as set by the user.
1.3.6.1.2.1.1.4 read-write
Provides an administratively-assigned name for this managed unit.1
ASCII character string, as set by the user.
1.3.6.1.2.1.1.5 read-write
Provides the physical location for this managed unit.1
ASCII character string, as set by the user.
1.3.6.1.2.1.1.6 read-write
C-2 7112-A2-GB20-10 March 1998

Object, OID, Access Setting/Contents Description
Functionality supported:
Object is set to 1+2+4+8 (15).
1.3.6.1.2.1.1.7 read-only
physical (1) – Layer 1
functionality for all interfaces.
– Layer 2 functionality
(SLIP/PPP) for all management links.
internet (4) – Layer 3
functionality (IP) for all management links.
end-to-end (8) – Layer 4
functionality (TCP/UDP) for all management links.
The Interfaces Group as defined in RFC 1573 consists of an object indicating the number of interfaces supported by the unit and an interface table containing an entry for each interface. Since RFC 1573 is an SNMPv2 MIB, it is converted to SNMPv1 for support by the unit. The following table provides clarification for objects contained in the Interfaces group when it is not clear how the object definition in RFC 1573 is supported by the unit.
Object Description Setting/Contents
ifNumber (interfaces 1) 1.3.6.1.2.1.2.1
Specifies the number of interfaces for this unit in the ifTable.
Provides the index to the interface table (ifTable) and to other tables as well.
Indexes and values:
1.3.6.1.2.1.2.2.1.1
When an unsupported index is entered (e.g., 1 and 5), noSuchName is returned.
C-3 7112-A2-GB20-20 March 1998

Object Setting/Contents Description
ifDescr (ifEntry 2) 1.3.6.1.2.1.2.2.1.2
Supplies text for each Interface:
Text Strings for each interface:
“Terminal Port; PARADYNE DS1
Leased Line DSU/CSU; Hardware Version [Hardware Revision]”
“Ethernet Port; PARADYNE DS1
Leased Line DSU/CSU; Hardware Version [Hardware Revision]”
“DS1 Network; PARADYNE DS1
Leased Line DSU/CSU; Hardware Version [Hardware Revision]”
User Data Port
“User Data Port; PARADYNE DS1
Leased Line DSU/CSU; Hardware Version [Hardware Revision]”
“FDL Channel; PARADYNE DS1
Leased Line DSU/CSU; Hardware Version [Hardware Revision]”
ifType (ifEntry 3) 1.3.6.1.2.1.2.2.1.3
Identifies the interface type based on the physical/link protocol(s), right below the network layer.
Supported values:
ethernetCsmacd(6) – Used for the
Ethernet port.
other(1) – Used for the DS1
network.
SLIP(28) – Used for the FDL
rs232(33) – Used for the Terminal
port.
v35(45) – Used for the User Data
port.
DS1(18) – Used for the Network
and DTE Drop/Insert T1 interfaces.
ifMtu (ifEntry 4) 1.3.6.1.2.1.2.2.1.4
Identifies the largest datagram that can be sent or received on an interface (Ethernet port or FDL).
Number of octets.
C-4 7112-A2-GB20-10 March 1998

Object Setting/Contents Description
ifSpeed (ifEntry 5) 1.3.6.1.2.1.2.2.1.5
Provides the current bandwidth for the interface in bits per second.
Ethernet Port – The data rate for
the port.
Terminal port – Configured data
rate for the port.
DS1 – Line rate of 56,000 or
64,000 bps, reflecting the line rate detected by the unit.
User data (DTE) port – Current
data rate of the port (DS1 operating rate minus FDL).
Facility Data Link – When FDL is
enabled, the data rate is 4 Kbps. When FDL is disabled, the data rate is zero.
ifAdminStatus (ifEntry 7) 1.3.6.1.2.1.2.2.1.7
Provides interface status. Supported as read-only.
up(1) – The interface is enabled.
down(2) – The interface is
disabled.
Ethernet Port – always down(2).
Terminal port – always up(1).
User data (DTE) port – always
up(1).
DS1 Network – always up(1).
Facility Data Link – Up(1) when
FDL enabled, down(2) when FDL disabled.
C-5 7112-A2-GB20-20 March 1998
MIB Descriptions

Object Setting/Contents Description
ifOperStatus (ifEntry 8) 1.3.6.1.2.1.2.2.1.8
Specifies the current operational state of the interface. Read/Write
– up(1) – No alarms – down(2) – Alarms – testing(3) – Test active
Terminal port. Always up(1); never
in testing(3) state.
User Data Port
– up(1) – No alarms – down(2) – Alarms – testing(3) – Test active
DS1 Network Interface
– up(1) – DTR on, if supported by
the DTE – down(2) – DTR off, if supported
by the DTE – testing(3) – Test active
Facility Data Link (FDL). When
enabled, up and down are based on the current state of the physical and link layer protocols.
– up(1) – Operational and no
active test on the DS1 network interface – down(2) – Not operational or
disabled – testing(3) – Test active on DS1
ifLastChange (ifEntry 9) 1.3.6.1.2.1.2.2.1.9
Indicates the amount of time the interface has been up and running.
Contains the value of sysUpTime object at the time the interface entered its current operational state.
ifInOctets (ifEntry 10) 1.3.6.1.2.1.2.2.1.10 Collects input statistics on data received by the interface
An integer number.
the interface.
ifInUcastPkts (ifEntry 11) 1.3.6.1.2.1.2.2.1.11
Applies to the FDL and
pp the Ethernet port. Statistics are not collected if the Ethernet port is
h E h ifInDiscards (ifEntry 13) 1.3.6.1.2.1.2.2.1.13
Ethernet port is disabled.
ifInErrors (ifEntry 14) 1.3.6.1.2.1.2.2.1.14
ifInUnknown Protos (ifEntry 15) 1.3.6.1.2.1.2.2.1.15
C-6 7112-A2-GB20-10 March 1998
MIB Descriptions · Ethernet port · network interface

Object Setting/Contents Description
ifOutOctets (ifEntry 16) 1.3.6.1.2.1.2.2.1.16
Collects output statistics on data received by the interface
An integer number.
interface.
ifOutUcastPkts (ifEntry 17) 1.3.6.1.2.1.2.2.1.17
Applies to the FDL and the Ethernet port. Statistics are not ifOutDiscards (ifEntry 19) 1.3.6.1.2.1.2.2.1.19
Statistics are not collected if the Ethernet port is disabled.
ifOutErrors (ifEntry 20) 1.3.6.1.2.1.2.2.1.20
This extension contains additional objects for the interface table. Supports only the following objects.
Object, OID, Access Description Setting/Contents
Provides name of the interface.
Interface text strings:
1.3.6.1.2.1.31.1.1.1.1 read-only
Indicates whether the link is up or down, or enterprise- specific traps should be generated.
Only supports T1 network and User data port.
SNMP Traps must be enabled for the unit. See Table A-10, SNMP Traps Option.
1.3.6.1.2.1.31.1.1.1.14 read-write
C-7 7112-A2-GB20-20 March 1998

Object, OID, Access Setting/Contents Description
Reflects the ifSpeed setting for the interface.
This object is supported for the Ethernet Network T1 and User Data Port only.
1.3.6.1.2.1.31.1.1.1.15 read-only
Supported as a read-only variable.
2 –ifSpeed from 1,500,000 to 1, 536,000 bps
Indicates whether there is a physical connector for the interface.
true(1) – Will always have this value for the Network T1, User Data port.
1.3.6.1.2.1.31.1.1.1.17 read-only
false(2) –Will always have this value for the FDL.
The Interface Stack Group is used by the unit to show the relationship between a logical interface and a physical interface. The following table provides clarification for objects contained in the Interface Stack group when it is not clear how the object definition in RFC 1573 is supported by the unit.
Object, OID, Access Description Setting/Contents
Provides the index that corresponds to the higher sublevel specified by ifStackLowerLayer.
When the FDL in-band management channel is enabled, this object for the network T1 interface is set to the ifIndex of the FDL. All other ifStackHigherLayer objects will have a value of zero.
1.3.6.1.2.1.31.1.2.1.1 read-only
Provides the index that corresponds to the lower sublevel specified by ifStackHigherLayer.
When the FDL in-band management channel is enabled, this object (for the FDL) is set to the ifIndex of the network T1 interface. All other ifStackLowerLayer objects will have a value of zero.
1.3.6.1.2.1.31.1.2.1.2 read-only
C-8 7112-A2-GB20-10 March 1998

Object, OID, Access Setting/Contents Description
Specifies the stack group’s status compared to the interface’s ifOperStatus.
When ifStackStatus set to
active – maps to ifOperStatus set to up(1) or testing(3).
1.3.6.1.2.1.31.1.2.1.3 read-only
When ifStackStatus set to not
in service – maps to ifOperStatus set to down(2).
Not supported by the unit.
Not supported by the unit.
The Internet Protocol Group objects are supported by the unit for all data paths that are currently configured to carry IP data to/from the unit. All of the objects in the IP Group, except for the IP Address Translation table, are fully supported. The following table provides clarification for objects contained in the IP group when it is not clear how the object definition in MIB II is supported by the unit.
Object, OID, Access Description Setting/Contents
Specifies whether the unit is acting as an IP gateway for forwarding of datagram received by, but not addressed to, the unit.
Supports only the following value:
1.3.6.1.2.1.4.1 read-write
forwarding(1) – The unit is
acting as a gateway.
The address table. Supported.
1.3.6.1.2.1.4.20 read-only
An IP address supported by the unit which serves as an index to the address table.
Indexes for tables must be unique. Therefore, only one ifIndex can be displayed for each IP address supported by the device. If the same IP address is configured for multiple interfaces, or for default IP addresses, the ipAddrTable will not display all of the interfaces that support a particular IP address.
1.3.6.1.2.1.4.20.1.1 read-only
C-9 7112-A2-GB20-20 March 1998

Object, OID, Access Setting/Contents Description
If this object has a greater value than the ifNumber, then it refers to a proprietary interface not currently implemented by the MIB II Interface Group.
1.3.6.1.2.1.4.20.1.2 read-only
Use caution when adding or modifying routes.
To delete a route, set object to invalid.
1.3.6.1.2.1.4.21 read-write
If it is absolutely necessary to add a route, the route should only be added to the connected device (device closest to the destination). Internal routing will continue the route to the other devices.
To modify a route, change fields in the desired entry of the routing table (indexed by ipRouteDest).
To add a route, specify values for a table entry for which the index (ipRouteDest) does not already exist. The following objects must be specified:
ipRouteDest – Serves as an
index to the routing table. Only one route per destination can appear in the table. To ensure that no duplicate destinations appear in the routing table, the ipRouteDest object will be treated as described in the IP Forwarding Table MIB (RFC 1354).
ipRouteIfIndex – If this object
has a greater value than the ifNumber, then it refers to a proprietary interface not currently implemented by the MIB II Interface Group. Do not delete route entries with an unrecognized ipRouteIfIndex. When setting this object via SNMP, the ipRouteIfIndex value can only assume an appropriate value of IfIndex defined for a particular device type.
Objects that will be set to the default value if not specified in the Set PDU used to add a route:
ipRouteMetric1 – Defaults to
1 hop.
ipRouteType – Defaults to
indirect.
ipRouteMask – Defaults to
what is specified in the MIB description.
Continued on next page.
C-10 7112-A2-GB20-10 March 1998

Object, OID, Access Setting/Contents Description
Objects that are not used by this unit:
ipRouteMetric3, ipRoutemetric4, ipRoutemetric5 – Default to –1.
Defaults to 0.0.0.0.
Do not specify the following read-only objects in the Set PDU used to add a route:
ipRouteProto – Set to
netmgmt(3) by the software.
ipRouteAge – Reflects the
value of the time-to-live for the route (in seconds). Defaults to 999 (permanent route).
ipRouteInfo – Unused; set to
{0, 0}.
The ICMP (Internet Control Management Protocol) Group objects are fully supported.
The TCP Group objects are fully supported, with the exception of tcpConnState object, which will be read-only, since deleteTCB (12) is not supported and is the only value which can be set.
The UDP Group objects are fully supported.
C-11 7112-A2-GB20-20 March 1998

Objects in the Transmission Group are supported on the T1 network interface, User Data port and Terminal port. These objects are defined through other Internet-standard MIB definitions rather than within MIB II.
Object Description
Supported on the Ethernet port. Defined by the Ethernet-like MIB (RFC 1643).
Supported on the User Data port and Terminal port. Defined by the RS-232-like MIB (RFC 1659).
ds1 (transmission 18) Supported on the DS1 network interface by Paradyne Enterprise MIB.
The SNMP Group objects that apply to a management agent are fully supported. The following objects apply only to an NMS and return a zero value if accessed.
snmpInTooBig (snmp 8)
snmpInNoSuchNames (snmp 9)
snmpInBadValues (snmp 10)
snmpInReadOnlys (snmp 11)
snmpInGenErrs (snmp 12)
snmpInGetResponses (snmp 18)
snmpInTraps (snmp 19)
snmpOutGetRequests (snmp 25)
snmpOutGetNexts (snmp 26)
snmpOutSetRequests (snmp 27)
C-12 7112-A2-GB20-10 March 1998
MIB Descriptions · dot3 (transmission 7) · rs232 (transmission 33)

The unit supports DS1/E1 MIB, RFC 1406 for the T1 network interface. The DS1 Near End Group and DS1 Fractional Group are supported for this interface. The DS1 Near End Group consists of the following tables:
DS1 Configuration, Table C-7
DS1 Current, Table C-8
DS1 Interval, Table C-9
DS1 Total, Table C-10
The DS1 Far End Group is not supported.
All four tables are supported for the T1 network interface. Clarification for objects contained in the tables as it applies to the unit is provided below.
The DS1 Far End Group is not supported.
The DS1 Near End Group Configuration Table Objects contains configuration options for the DS1/E1 interfaces. Clarification for objects contained in this table as it applies to the unit is provided below.
Object, OID, Access Description Setting/Contents
The number of seconds that have elapsed since the start of the current error-measurement period.
Supports the following values:
1.3.6.1.2.1.1.10.18.6.1.3 read-only
0 to 899.
Applies to the T1 network interface only.
Contains the number of previous intervals for which valid data was collected.
Supports the following values:
1.3.6.1.2.1.1.10.18.6.1.4 read-only
0 to 96.
Applies to the T1 network interface only.
The value is 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute intervals since the interface has been online.
Corresponds to the network framing configuration option for the network interface on the DSU/CSU.
Supports the following values:
1.3.6.1.2.1.1.10.18.6.1.5 read-write
dsx1ESF(2) – Indicates
ESF framing.
dsx1D4(2) – Indicates D4
framing.
C-13 7112-A2-GB20-20 March 1998

Object, OID, Access Setting/Contents Description
Corresponds to the network line coding configuration option for the network interface on the DSU/CSU.
Supports the following values:
1.3.6.1.2.1.1.10.18.6.1.6 read-write
dsx1B8ZS(2) – Indicates
B8ZS line coding.
dsx1AMI(5) – Indicates
AMI line coding.
Indicates the test patterns/codes being sent over the network interface.
Supports the following values:
1.3.6.1.2.1.1.10.18.6.1.7 read-write
specifies that the interface is sending normal or looped data. Setting the interface to this value stops an active “send pattern” test on the interface.
specifies that the network interface is sending a Remote Loopback UP code for 10 seconds.
specifies that the network interface is sending a Remote Loopback DOWN code for 10 seconds.
specifies that the network interface is sending a QRSS test pattern. The pattern is sent until the test is halted (i.e., setting to dsx1SendNoCode).
rn(8) – specifies that the network interface is sending a 1-in-8 test pattern. The pattern is sent until the test is halted (i.e., setting to dsx1SendNoCode).
Contains the transmission vendor’s circuit identifier, for the purpose of facilitating troubleshooting.
A string of 0 to 255 characters.
1.3.6.1.2.1.1.10.18.6.1.8 read-write
Applies to the T1 network interface only.
C-14 7112-A2-GB20-10 March 1998

Object, OID, Access Setting/Contents Description
This object specifies the loopback state of the network interface.
Supports the following values:
1.3.6.1.2.1.1.10.18.6.1.9 read-write
dsx1NoLoop(1) – The T1
Applies to the T1 network interface only.
interface is not in a loopback state.
Specifies that a Payload Loopback (PLB) is active for the network interface.
Specifies that a Line Loopback (LLB) is active for the network interface.
Specifies that an unspecified type of loopback is active for the network interface.
This object specifies the line (alarm) status of the network interface.
More than one value may be active at a time.
1.3.6.1.2.1.1.10.18.6.1.10 read-only
Supports the following values:
dsx1NoAlarm(1) – No
alarm present.
A yellow alarm signal is being received.
dsx1RcvAIS(8) – An
Alarm Indication Signal (AIS) is being received.
dsx1LossOfFrame(32) –
An Out Of Frame condition has persisted for more than 2.5 seconds (i.e., Red Alarm).
A Loss of Signal condition has persisted for more than 2.5 seconds (i.e., Red Alarm).
– The near end of the network interface is in a loopback state.
– An Excessive Error Rate (EER) has been detected on the network interface.
C-15 7112-A2-GB20-20 March 1998

Object, OID, Access Setting/Contents Description
This object specifies whether Robbed Bit Signaling (RBS) is being used. This object differs from the MIB definition in that it is not read/write. RBS is not supported in this product.
Supports the following value:
none(1) – No signaling is
1.3.6.1.2.1.1.10.18.6.1.11 read-only
being used on this interface.
dsx1TransmitClock– Source (dsx1ConfigEntry 12)
This object specifies the timing source for the transmit clock for this T1 interface. This object differs from the MIB definition in that it is “read-only” (not read/write) for DSU/CSUs.
Supports the following values:
loopTiming(1) – The
1.3.6.1.2.1.1.10.18.6.1.12 read-only
recovered receive clock is being used as the transmit clock.
localTiming(2) – The
DSU/CSU’s internal clock is used being as the transmit clock.
ThroughTiming(3) – The
recovered receive clock from another interface (e.g., network or synchronous data port) is being used as the transmit clock.
This object specifies how Facility Data Link is being used.
More than one value may be active at a time.
1.3.6.1.2.1.1.10.18.6.1.13 read-write
Supports the following values:
dsx1other(1) – SNMP
data is being sent over FDL.
ANSI PRMs are supported on the network interface as specified by ANSI T1.403.
dsx1Att-54016(4) – FDL
supports the requirements specified by AT&T publication TR54016.
Indicates that the device does not use FDL.
C-16 7112-A2-GB20-10 March 1998

The DS1 Near End Group Current Table contains various statistics being collected for the current 15-minute interval. The following objects are provided for the network interface only. Objects in the DS1 Current Table that are not listed below are not supported and will return an error status if access is attempted.
Object, OID, Access Description Setting/Contents
The index that identifies the network interface.
Supports the following values:
1.3.6.1.2.1.1.10.18.7.1.1 read-only
1 to 7FFFFFFF.
Errored Seconds for the current interval.
An integer number.
1.3.6.1.2.1.1.10.18.7.1.2 read-only
Severely Errored Seconds for the current interval.
1.3.6.1.2.1.1.10.18.7.1.3 read-only
Unavailable Seconds for the current interval.
1.3.6.1.2.1.1.10.18.7.1.5 read-only
Controlled Slip Seconds for the current interval.
1.3.6.1.2.1.1.10.18.7.1.6 read-only
Bursty Errored Seconds for the current interval.
1.3.6.1.2.1.1.10.18.7.1.9 read-only
C-17 7112-A2-GB20-20 March 1998

The DS1 Near End Group Interval Total Table contains the cumulative sum of the various statistics for the 24-hour period preceding the current interval. The following objects are provided for the network interface only. Objects in the DS1 Interval Table that are not listed below are not supported and will return an error status if access is attempted.
Object, OID, Access Description Setting/Contents
The index that identifies the network interface.
Supports the following values:
1.3.6.1.2.1.1.10.18.8.1.1 read-only
1 to 7FFFFFFF.
Interval number. A number between 1 and 96, where 1 is the most recently completed 15-minute interval and 96 is the least recently completed 15-minute interval (assuming that all 96 intervals are valid).
1.3.6.1.2.1.1.10.18.8.1.2 read-only
Errored Seconds for the interval.
An integer number.
1.3.6.1.2.1.1.10.18.8.1.3 read-only
Severely Errored Seconds for the interval.
1.3.6.1.2.1.1.10.18.8.1.4 read-only
Unavailable Seconds for the interval.
1.3.6.1.2.1.1.10.18.8.1.6 read-only
Controlled Slip Seconds for the interval.
1.3.6.1.2.1.1.10.18.8.1.6 read-only
Bursty Errored Seconds for the interval.
1.3.6.1.2.1.1.10.18.8.1.10 read-only
C-18 7112-A2-GB20-10 March 1998

The DS1 Near End Group Total Table contains various statistics being collected for the current 15-minute interval. The following objects are provided for the network interface only. Objects in the DS1 Total Table that are not listed below are not supported and will return an error status if access is attempted.
Object, OID, Access Description Setting/Contents
The index that identifies the network interface.
Supports the following values:
1 to 7FFFFFFF.
1.3.6.1.2.1.1.10.18.9.1.1 read-only
Errored Seconds for the previous 24-hour interval.
An integer number.
1.3.6.1.2.1.1.10.18.9.1.2 read-only
Severely Errored Seconds for the previous 24-hour interval.
1.3.6.1.2.1.1.10.18.9.1.3 read-only
Unavailable Seconds for the previous 24-hour interval.
1.3.6.1.2.1.1.10.18.9.1.5 read-only
Controlled Slip Seconds for the previous 24-hour interval.
1.3.6.1.2.1.1.10.18.9.1.6 read-only
Bursty Errored Seconds for the previous 24-hour interval.
1.3.6.1.2.1.1.10.18.9.1.9 read-only
C-19 7112-A2-GB20-20 March 1998

The DS1 Fractional Group consists of the DS1 fractional table. This table (dsx1FracTable) is fully supported by the DSU/CSU and allows DS0 (time slots) to be mapped between the network interface and the data port. The DSU/CSU validates all channel configurations before applying them.
The unit supports the Ethernet-Like MIB, RFC 1643 for all objects except:
The unit supports RS-232-Like MIB, RFC 1659:
Number of RS-232-Like Ports Object.
General Port Table Objects, Table C-11.
Asynchronous Port Table Objects, Table C-12. Not supported for the User Data port.
Synchronous Port Table Objects, Table C-13. Not supported for the Terminal port.
Input Signal Table Objects, Table C-14. Not supported for the Terminal port.
Output Signal Table Objects, Table C-15. Not supported for the Terminal port.
Supported for the User Data port and the Terminal port. RFC 1659 is an SNMPv2 MIB, but is converted to an SNMPv1 MIB to support this unit. This MIB consists of one object and five tables.
Supported as documented in the RFC.
The General Port Table Objects contains configuration options for the RS-232-Like interfaces. Clarification for objects contained in this table as it applies to the unit is provided below.
C-20 7112-A2-GB20-10 March 1998

Object, OID, Access Description Setting/Contents
Identifies the port hardware type.
Supports only the following values:
1.3.6.1.2.1.10.33.2.1.2 read-only
rs232(2) – Identifies the Terminal port.
v35(5) – Identifies the synchronous User Data port which is compatible with the V.35 standard.
Contains the number of input signals (in the input signal table) that can be detected.
The value is 2 for synchronous user data port and 0 for the Terminal port.
1.3.6.1.2.1.10.33.2.1.3 read-only
Contains the number of output signals (in the output signal table) that can be asserted.
The value is 3 for synchronous User Data port and 0 for the Terminal port.
1.3.6.1.2.1.10.33.2.1.4 read-only
Contains the port’s output speed in bits per second.
Supports the following speeds for the Terminal port: 2400, 4800, 9600,14,400, 19,200, 28,800, 38,400.
1.3.6.1.2.1.10.33.2.1.6 read-write
The rs232PortOutSpeed object has the same values as the rs232PortInSpeed object.
The following are not supported:
rs232PortInFlowType (rs232PortEntry 7)
rs232PortOutFlowType (rs232PortEntry 8)
C-21 7112-A2-GB20-20 March 1998

The Asynchronous Port Table Objects contains an entry for the Terminal port. For this unit, entries in the table that are counters (rs232AsyncPortEntry 6–8) are used to collect statistics only and are not supported.
Object, OID, Access Description Setting/Contents
Specifies the number of bits in a character.
Supports only the following values:
1.3.6.1.2.1.10.33.3.1.2 read-write
Specifies the number of stop bits supported.
Supports only the following values:
1.3.6.1.2.1.10.33.3.1.3 read-write
one(1) – One stop bit
two(2) – Two stop bits
Specifies the type of parity used by the port.
Supports only the following values:
1.3.6.1.2.1.10.33.3.1.4 read-write
none(1) – No parity bit
odd(2) – Odd parity
even(3) – Even parity
Specifies the ability to automatically sense the input speed of the port.
Supports only the following values:
disabled(2) – Does not support Autobaud.
1.3.6.1.2.1.10.33.3.1.5 read-write
C-22 7112-A2-GB20-10 March 1998

The Synchronous Port Table Objects contains an entry for the synchronous user data port when this port is configured for synchronous operation. For this unit, entries in the table that are counters (rs232SyncPortEntry 3–7) are used to collect statistics only and are not supported. Clarification for objects contained in this table as it applies to the unit is provided below.
Object, OID, Access Description Setting/Contents
Specifies the clock source for the port.
Supports only the following values:
internal(1) – The port uses an internal clock.
1.3.6.1.2.1.10.33.4.1.2 read-write
external(2) – The port uses an external clock.
Specifies whether this device interface is a DTE or DCE.
Supports only the following value:
1.3.6.1.2.1.10.33.4.1.8 read-write
dce(2) – The port acts as a DCE.
Specifies the bit encoding technique that this port uses.
Supports only the following value:
1.3.6.1.2.1.10.33.4.1.9 read-write
nrz(1) – The port uses non-return to zero encoding.
nrzi(2) – The port uses non-return to zero-inverted encoding. This corresponds to the inverted transmit and receive data relationship.
Specifies the method used to control the RTS signal.
Supports only the following values:
controlled(1) – For User Data port, this value is used when the Data Port option Carrier Control by RTS is set to Switched.
1.3.6.1.2.1.10.33.4.1.10 read-write
constant(2) – For User Data port, this value is used when the Data Port option Carrier Control by RTS is set to Constant.
C-23 7112-A2-GB20-20 March 1998

Object, OID, Access Setting/Contents Description
Specifies the port’s mode of data transfer.
Supports only the following value:
1.3.6.1.2.1.10.33.4.1.12 read-write
Specifies the minimum number of flag patterns the port needs in order to recognize the end of one from and the start of another.
The only valid value is 2.
1.3.6.1.2.1.10.33.4.1.14 read-write
The following is not supported:
rs232SyncPortIdle Pattern (rs232SyncPortEntry 13)
The Input Signal Table Objects contains entries for the input signals that can be detected by the unit for the synchronous user data port. Clarification for objects contained in this table as it applies to the unit is provided below.
Object, OID, Access Description Setting/Contents
Contains the identification of a hardware input signal.
Supports only the following values:
1.3.6.1.2.1.10.33.5.1.2 read-only
rts(1) – Request To Send
dtr(4) – Data Terminal Ready
Contains the current signal state.
Supports only the following values:
1.3.6.1.2.1.10.33.5.1.3 read-only
on(2) – The signal is asserted.
off(3) – The signal is deasserted.
Indicates the number of times that a signal has changed from on to off, or off to on.
The object is incremented each time that the signal is sampled (every 100 ms) and the signal state is different from the previous state.
1.3.6.1.2.1.10.33.5.1.4 read-only
C-24 7112-A2-GB20-10 March 1998

The Output Signal Table Objects contains entries for the output signals that can be asserted by the unit, for the synchronous User Data port. Clarification for objects contained in this table as it applies to the unit is provided below.
Object, OID, Access Description Setting/Contents
Contains the identification of a hardware output signal.
Supports only the following values:
1.3.6.1.2.1.10.33.6.1.2 read-only
cts(2) – Clear To Sen
DS1r(3) – Data Set Ready
Contains the current signal state.
Supports only the following values:
1.3.6.1.2.1.10.33.6.1.3 read-only
on(2) – The signal is asserted.
off(3) – The signal is deasserted.
Indicates the number of times that a signal has changed from on to off, or off to on.
Increments the object each time that the signal is sampled (every 100 ms) and the signal state is different from the previous state.
1.3.6.1.2.1.10.33.6.1.4 read-only
C-25 7112-A2-GB20-20 March 1998

The unit supports the Generic Interface Extension MIB (RFC 1229):
Table C-16, Generic Interface Test Table Objects
The DSU/CSU only supports the Generic Interface Test Table in the Generic Interface Extension MIB.
The Generic Interface Test Table Objects are used to access additional tests (loopbacks and pattern tests) that are not provided in the interface group of MIB II. Clarification for objects contained in this table as it applies to the unit is provided below.
Object Description Setting/Contents
A control variable used to start and stop user-initiated tests on the interface. The following tests may be controlled:
The following objects use identifiers to control tests on the network T1 and User Data port interface:
1.3.6.1.3.6.2.1.4 read-write
notest(0 0) – Stops the test in
progress on the network T1 or User Data port interface.
Monitor QRSS test
pattern on the network T1 interface.
testMon QRSS (wellKnownTests
Send QRSS/511 test
pattern on the User Data port.
Send V.54/FT1 up/down
code to the remote unit for the User Data port.
Monitor QRSS/511 test
pattern on the User Data port.
Data Channel and Data
Terminal Loopbacks on the User Data port.
Continued on next page.
C-26 7112-A2-GB20-10 March 1998
MIB Descriptions · ifExtnsTestType (ifExtnsTestEntry 4)

Object Setting/Contents Description
The following objects use identifiers to control tests only on the User Data port interface:
(wellKnownTests 1) – Starts a Data Channel Loopback (DCLB) on the interface.
(wellKnownTests 2) – Starts a Data Terminal Loopback (DTLB) on the interface.
testMon 511 (wellKnownTests 4)
– Starts a Monitor 511 test on the interface.
(wellKnownTests 5) – Starts a Send QRSS test on the interface.
(wellKnownTests 6) – Starts a Send 511 test on the interface.
(wellKnownTests 7) – Sends a V.54 up code to the remote unit.
(wellKnownTests 8) – Sends a V.54 down code to the remote unit.
(wellKnownTests 9) – Sends a FTI up code to the remote unit.
(wellKnownTests 10) – Sends a FT1 down code to the remote unit.
C-27 7112-A2-GB20-20 March 1998

Object Setting/Contents Description
Contains the result of the most recently requested test.
Supports the following values:
none(1) – No test active.
1.3.6.1.3.6.2.1.5 read-only
inProgress(3) – Test is in
progress.
notSupported(4) – Requested
test is not supported.
unAbleToRun(5) – Test cannot
run due to the state of the unit.
Contains a code providing more specific information about the test result.
Supports the following values:
none (wellKnownCodes 1) – No
further information is available. Used for send pattern/code and loopback tests.
1.3.6.1.3.6.2.1.6 read-only
(wellKnownCodes 2) – A monitor pattern (QRSS or 511) test has synchronized on the pattern and has not detected any bit errors.
(wellKnownCodes 3) – A monitor pattern (QRSS or 511) test has synchronized on the pattern but has detected any bit errors.
notInSync (wellKnownCodes 4)
– A monitor pattern (QRSS or 511) test has not synchronized on the requested pattern.
C-28 7112-A2-GB20-10 March 1998

The following Paradyne Enterprise MIB Object is supported by the unit:
Device Configuration Variable, Table C-17
The variable devConfigAreaCopy in the devConfigArea group is supported. This variable allows the entire contents of one configuration area to be copied into another configuration area. The unit only supports the following values.
Object, OID, Access Description Setting/Contents
A “get” of this object will always return noOp.
1 3 6 1 4 1 1795 2 24 2 7 1 1
1.3.6.1.4.1.1795.2.24.2.7.1.1 read-write Copy from active area to customer 1 area.
Copy from active area to customer 2 area.
Copy from customer 1 area to active area.
Copy from customer 1 area to customer 2 area.
Copy from customer 2 area to active area.
Copy from customer 2 area to customer 1 area.
Copy from factory area to active area. There is only one factory area for the unit.
Copy from factory area to customer 1 area.
Copy from factory area to customer 2 area.
Use the Device Security table to control the number of SNMP managers that may access the unit, as well as the unit access level (read or read/write). Fully supported by the unit.
Controls the SNMP managers to which the unit reports traps. Fully supported by the unit.
Uses the devControlReset object to reset the unit. Fully supported by the unit.
C-29 7112-A2-GB20-20 March 1998

This page intentionally left blank.
C-30 7112-A2-GB20-10 March 1998
MIB Descriptions

Overview
This section describes the unit’s compliance with SNMP standards and any special operational features for the SNMP traps supported. The unit supports the following user interface traps and enterprise-specific traps:
warmStart The unit has reinitialized itself.
Reset command.
Power disruption.
The trap is sent after the unit resets and stabilizes.
There are no variable-bindings.
Along with the authenticationFailure MIB, a string is returned that identifies the IP address of the workstation that attempted to access the unit.
To display the address of the workstation that attempted to access the unit, you must customize your SNMP trap by adding $1 after authentication failure.
D-1 7112-A2-GB20-20 March 1998

Standards Compliance for SNMP Traps
authenticationFailure Failed attempts to access the unit.
SNMP message not properly
authenticated.
There are no variable-bindings.
Three unsuccessful attempts
were made to enter a correct login/password combination.
IP address security is
enabled, and a message was received from SNMP manager whose address was not on the list of approved managers.
Attempt to set a read-only MIB
object.
The link SNMP traps are:
linkUp – The unit recognizes that one of the failed communication interfaces is operational (up).
linkDown – The unit recognizes a failure in one of the communication interfaces.
D-2 7112-A2-GB20-10 March 1998

Standards Compliance for SNMP Traps
The following table describes the conditions that define linkUp and linkDown for each interface:
Interface
Physical Sublayer – Represented by the entry in the MIB II Interfaces Table.
ifIndex (RFC 1573)
linkDown – One or more
alarm conditions are active on the interface. Alarm conditions include:
(Supported by the media-specific ds1 MIB.)
ifOperStatus (RFC 1573)
– Loss of Signal – Out of Frame – Alarm Indication Signal – Excessive Error Rate – Yellow Alarm
ifType (RFC 1573)
linkUp – No alarms on the
interface.
Synchronous User Data Port
ifIndex (RFC 1573)
linkDown – One or more
alarm conditions are active on the interface. Alarm conditions include:
(Supported by the media-specific RS232-Like MIB.)
ifOperStatus (RFC 1573)
– DTR Off (only if the DTE
supports the DTR lead and the port is configured to monitor DTR. – RTS Off (only if the DTE
ifType (RFC 1573)
supports the RTS lead).
linkUp – No alarms on the
interface.
D-3 7112-A2-GB20-20 March 1998

Standards Compliance for SNMP Traps
The enterpriseSpecific trap indicates that an enterprise-specific event has occurred. The Specific-trap field in the Trap PDU identifies the particular trap that occurred. The following table lists the enterprise specific traps supported by the unit:
The currently configured primary clock source has failed.
The T1 network is down.
enterpriseSelfTestFail(2) A hardware failure of the unit is detected during the unit’s self-test. The trap is generated after the unit completes initialization.
Failure of one or more of the unit’s hardware components.
enterpriseDeviceFail(3) An internal device failure. Operating software has detected an internal device failure.
enterpriseTestStart(5) A test is running. At least one test has been started on an interface.
enterpriseConfigChange(6) The configuration changed via the user interface or an SNMP manager. The trap is sent after 60 seconds have elapsed without another change. This suppresses the sending of numerous traps when multiple changes are made in a short period of time, as is typically the case when changing configuration options.
Configuration has been changed via the user interface or an SNMP manager.
enterpriseTestStop(105) All tests have been halted. All tests have been halted on an interface.
There are no variable-bindings for enterprisePrimaryClockFail, enterpriseDeviceFail, and enterpriseConfigChange. The variable-binding for enterpriseSelfTestFail is devSelfTestResults.
D-4 7112-A2-GB20-10 March 1998
enterprisePrimaryClockFail (1)

Standards Compliance for SNMP Traps
The tests that affect the enterpriseTestStart, enterpriseTestStop, and the variable-binding are different for each particular interface. Diagnostic tests are only supported on the physical T1 network and user data port interfaces. The specific tests and variable-bindings are described in the following table:
Interface
T1 network ifIndex (RFC 1573)
enterpriseTest Start – Any one
of the following tests is active on the interface:
– Remote Line Loopback – Send QRSS pattern
ifOperStatus (RFC 1573)
ifType (RFC 1573)
enterpriseTest Stop – No
longer has any tests running on the interface.
ifIndex (RFC 1573)
enterpriseTest Start – Any one
of the following tests is active on the interface:
– Line Loopback – Payload Loopback
ifOperStatus (RFC 1573)
ifType (RFC 1573)
enterpriseTest Stop – No
longer has any tests running on the interface.
ifIndex (RFC 1573)
enterpriseTest Start – Any one
of the following tests is active on the interface:
– Repeater Line Loopback – Send 1-in-8 pattern – All Monitor Pattern tests
ifOperStatus (RFC 1573)
ifType (RFC 1573)
ifTestType (RFC 1573)
enterpriseTest Stop – No
longer has any tests running on the interface.
Synchronous User Data Ports
ifIndex (RFC 1573)
enterpriseTest Start – Any one
of the following tests is active on the port:
– Local Loopback (DTE) – Send 511 pattern – Monitor 511 pattern
ifOperStatus (RFC 1573)
ifType (RFC 1573)
ifTestType (RFC 1573)
enterpriseTest Stop – No
longer has any tests running on the port.
D-5 7112-A2-GB20-20 March 1998

Standards Compliance for SNMP Traps
This page intentionally left blank.
D-6 7112-A2-GB20-10 March 1998

E
Cabling Overview
The following sections provide pin assignments:
Modular RJ48C-to-RJ48C T1 Network Interface Cable
Modular RJ48C-to-CA81A T1 Network Interface Cable
Terminal Port EIA-232 Connector
Serial Crossover Cable
DTE V.35 Connector
E-1 7112-A2-GB20-20 March 1998
10BaseT Connector

Cables and Pin Assignments
Network access in the United States is via a 20-foot modular cable with an RJ48C plug connector on each end.
RJ48C
PLUG UNKEYED
PLUG UNKEYED
BLUE
TWISTED PAIR
BLUE
RECEIVE RING
WHITE
WHITE
RECEIVE TIP
ORANGE
TWISTED PAIR
ORANGE
TRANSMIT RING
WHITE
WHITE
TRANSMIT TIP
Modular RJ48C-to-CA81A T1 Network Interface Cable
Network access in Canada is via a 20-foot modular cable with a CA81A plug connector on one end and an RJ48C plug connector on the other end.
DA15P
PLUG UNKEYED
PLUG
BLUE
BLUE
RECEIVE RING
RECEIVE RING
RECEIVE TIP
RECEIVE TIP
WHITE/BLUE
WHITE/BLUE
ORANGE
ORANGE
TRANSMIT RING
TRANSMIT RING
TRANSMIT TIP
TRANSMIT TIP
WHITE/ORANGE
WHITE/ORANGE
E-2 7112-A2-GB20-10 March 1998
493-14156-01 · 493-14342

Cables and Pin Assignments
The Terminal port connects to a PC or VT100-compatible terminal.
Transmit Data (TXD) To DSU/CSU (In) 2
Received Data (RXD) From DSU/CSU (Out) 3
Request to Send (RTS) To DSU/CSU (In) 4
Clear to Send (CTS) From DSU/CSU (Out) 5
Data Set Ready (DSR) From DSU/CSU (Out) 6
Signal Ground (SG) — 7
Carrier Detect (CD) From DSU/CSU (Out) 8
Data Terminal Ready (DTR) To DSU/CSU (In) 20
Use a standard 10BaseT cable to connect the DSU to an Ethernet LAN. A cable is provided with the DSU.
The following table defines the pinouts for the 10BaseT port. It is an 8-pin, unkeyed jack.
Transmitted Data + 1
Transmitted Data – 2
Received Data + 3
NC 5
Received Data – 6
NC 8
NC = Not connected (unused).
E-3 7112-A2-GB20-20 March 1998

Cables and Pin Assignments
Use a serial crossover cable to connect an external modem to the DSU/CSU’s COM port.
The Pin 17 to Pin 24 crossovers are not required and have no effect with the Model 7112.
Pin 1 Pin 14
Pin 1 Pin 14
Pin 13 Pin 25
Pin 13 Pin 25
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Chassis Ground TXD RXD RTS CTS DSR Signal Ground CD (RLSD)
RTS CTS DSR Signal Ground
TXC
TXC
RXC
RXC
DTR
DTR
XTXC
XTXC
E-4 7112-A2-GB20-10 March 1998

Cables and Pin Assignments
The following table provides the pin assignments for the 34-position V.35 connector to the DTE.

Request to Send (RTS) 105 To DSU/CSU (In) C
Data Terminal Ready (DTR) 108/1, /2 To DSU/CSU (In) H
Transmitted Data (TXD) 103 To DSU/CSU (In) P (A) S (B)
Transmitter Signal Element Timing — DTE Source (XTXC or TT)
E-5 7112-A2-GB20-20 March 1998

Cables and Pin Assignments
This page intentionally left blank.
E-6 7112-A2-GB20-10 March 1998

F
Item Specifications
Approvals Refer to the product labeling
Clock Sources T1 network interface, Port, or internal clock
Environment Operating Temperature Storage Temperature Relative Humidity Shock and Vibration
32°F to 122°F (0°C to 50°C) –4°F to 158°F (–20°C to 70°C) 5%—95% (noncondensing) Withstands normal shipping and handling
AT&T TR 54016, AT&T TR 62411, ANSI T1.4031989 LLB (Line Loopback), PLB (Payload Loopback), RLB (Repeater Loopback), DTLB (Data Terminal Loopback), DCLB (Data Channel Loopback) V.54 Loop 2 and Loop 3, ANSI T1.403 Annex B Fractional T1 Loopback
F-1 7112-A2-GB20-20 March 1998
Loopbacks Standard Additional

Item Specifications
MIB II Object Groups Supported
Interfaces group:
– T1 network – DTE Data port – Terminal port – Ethernet port
Transmission group:
– T1 network – DS1/E1 MIB – DTE Data port – RS-232-Like MIB – Terminal port – RS-232-Like MIB – Ethernet port – Ethernet-Like MIB
Physical Interface (USA) Physical Interface (Canada)
RJ48C CA81A using adapter cable (optional, Feature 3100–F1–501) D4, ESF AMI, B8ZS 0.0 dB, –7.5 dB, –15 dB, –22.5 dB Selectable FCC Part 68, AT&T TR 62411
Framing Format Coding Format Line Build-Out (LBO) ANSI PRM Bit Stuffing
NMS Compatibility SNMP Network Manager
Height (including feet) Height (without feet) Width Depth (case) Depth (case and connectors) Weight
2.1 inches (5.3 cm) 2.0 inches (5.1 cm) 8.7 inches (22.1 cm) 6.2 inches (15.7 cm) 6.5 inches (16.5 cm) 1 lb, 6 oz. (625 g)
Port Interface Standards Rates
V.35 Nx64 – 64K-1.536 Mb Nx56 – 56K-1.344 Mb
Power Consumption and Dissipation
4.5 watts, 15.4 Btu per hour at 120 volts (ac power)
Power Requirements AC Power Module Refer to the labeling on the ac power module for input requirements
F-2 7112-A2-GB20-10 March 1998

Alternate Channel Alternate Mark Inversion. A method of allocating DS0 channels as a group, so that every alternate DS0 channel does not carry data, but instead transmits and receives all ones.
A software program housed within a device to provide SNMP functionality. Each SNMP agent stores management information and responds to the manager’s request.
A single bit stream that combines two or more bit streams.
Alarm Indication Signal. A signal transmitted instead of the normal signal to maintain transmission continuity and to indicate to the receiving device that a transmission fault exists.
Alternate Mark Inversion. A line coding technique used to accommodate the ones density requirements of T1 lines.
American Standard Code for Information Interchange. A 7-bit code that establishes compatibility between data services. ASCII is the standard for data transmission over telephone lines.
Devices that can be attached, either locally or remotely, to display or print the DSU’s alarm messages.
A data transmission that is synchronized by a transmission start bit at the beginning of a character (five to eight bits) and one or more stop bits at the end.
Asynchronous terminal interface. This feature allows a device to be controlled from an async (asynchronous) terminal like an ASCII (VT100-compatible) terminal.
An operational mode in which the DSU forces automatic setting of the DDS line rate/speed (56 or 64 kbps) as soon as a valid DDS network signal is detected.
The auxiliary communications port on a router.
Bursty Errored Seconds. Seconds with more than one, but less that 320 CRC6 errors.
A method of allocating DS0 channels as a group rather than individually.
Bipolar Violation. A modified bipolar signaling method in which a control code is inserted.
Bipolar with Eight Zero Substitution. A line coding technique used to accommodate the ones density requirement of T1 lines.
Circuit Card Assembly. A printed circuit board to which separate components are attached.
Consultative Committee on International Telegraphy and Telephony. See ITU.
Carrier Detect. A signal indicating that energy exists on the transmission circuit. Associated with Pin 8 on an EIA-232 interface.
An independent data path.
GL-1 7112-A2-GB20-20 March 1998

Assigning specific DS0 channels in the DSU/CSU to specific interfaces (network, DTE Drop/Insert, etc.).
An identification used by SNMP to grant an SNMP server access rights to a MIB.
Device software that sets specific operating parameters for the DSU.
Customer Premises Equipment. Terminating equipment supplied by either the customer or some other supplier that is connected to the telecommunications network (e.g., DSUs, terminals, phones, routers, modems).
Cyclic Redundancy Check. A mathematical method of confirming the integrity of received digital data.
Canadian Standards Association.
Channel Service Unit. The function of the DSU that protects the T1 line from damage and regenerates the T1 signal.
Clear to Send. An EIA-lead standard for V.24 circuit CT 106; an output signal (DCE-to-DTE).
The electrical interface between the DSU/CSU and the synchronous data terminal equipment.
Data Communications Equipment. The equipment that provides the functions required to establish, maintain, and end a connection. It also provides the signal conversion required for communication between the DTE and the network.
Data Channel Loopback. Loops the data received from the network interface, for all DS0 channels allocated to the selected port, back to the network.
A preset value that is assumed to be correct unless changed by the user.
A signal composed of discrete elements (zeros and ones) instead of a great multitude of analog elements.
Defines objects for managing the network and DTE Drop/Insert interfaces on the DSU/CSU.
Data Set Ready. An EIA-lead standard for V.24 circuit CT 107; an output signal (DCE-to-DTE).
Data Service Unit. Data communications equipment that provides an interface between the DTE and the digital network.
Digital Signal Level 0.
Assigning specific DS0 channels in the DSU/CSU to specific interfaces (network, DTE Drop/Insert, etc.).
Data Terminal Equipment. The equipment, such as computers and printers, that provides or creates data.
Data Terminal Loopback. Loops the data received from the selected port, for all DS0 channels allocated to the port, back out the port.
Data Terminal Ready. An EIA-lead standard for V.24 circuit CT 108; an input signal (DTE-to-DCE).
The transmission standard that specifies 12 frames as a superframe that is used for frame synchronization and to locate signaling bits.
Excessive Error Rate. An error rate that is greater than the threshold in the DSU/CSU.
GL-2 7112-A2-GB20-20 March 1998
Glossary

Electronic Industries Association. This organization provides standards for the data communications industry to ensure uniformity of interface between DTEs and DCEs.
The EIA’s standards defining the 25-pin interface between the DTE and DCE.
MIB objects unique to Paradyne devices.
A trap unique to Paradyne devices.
Errored seconds. Seconds with one or more ESF error events.
Extended Superframe. The T1 transmission standard that specifies 24 frames as an extended superframe to be used for frame synchronization and to locate signaling bits.
An excessive bipolar violation condition results when at least one invalid bipolar violation has occurred every 20 milliseconds for 2 seconds.
A predetermined set of configuration options for general operation.
Federal Communications Commission. Board of Commissioners that regulates all U.S. interstate, intrastate, and foreign electrical communication systems that originate from the United States.
Facility Data Link. Selected bits in the ESF format that are used for control, monitoring, and testing.
Fractional T1. Individual DS0 channels that may be sold separately or in groups to provide bandwidth that is some fraction of the total T1 capability.
The capability to transmit in two directions simultaneously.
High-Level Data Link Control. A communications protocol defined by the International Standards Organization (ISO).
Internet Control Management Protocol. Internet protocol that allows for the generation of error messages, tests packets, and information messages related to IP.
A shared boundary between functional units.
Internet Protocol. The TCP/IP standard protocol that defines the unit of information passed across an Internet and provides the basis for packet delivery service. IP includes the ICMP control and error message protocol as an integral part. The entire protocol suite is often referred to as TCP/IP because TCP and IP are the two most fundamental protocols.
The IP address has a host component and a network component. The address is assigned to hosts or workstations with direct Internet access to uniquely identify entities on the Internet.
International Telecommunication Union, formerly known as CCITT. An advisory committee established by the United Nations to recommend communications standards and policies.
Local Area Network. A network designed to connect devices over short distances, like within a building.
Light Emitting Diode. A status indicator that responds to the presence of a certain conditions.
The protocol that regulates the communication between two network nodes.
Local Loopback. An EIA-lead standard for V.24 circuit CT 141; an input signal (DTE-to-DCE).
Line Loopback. Loops the received signal on the network interface back to the network without change.
GL-3 7112-A2-GB20-20 March 1998
Glossary

Loss of Frame. The inability to maintain frame synchronization.
Loss of Frame Count. A count of the number of LOFs declared.
Used to test various portions of a data link in order to isolate an equipment or data line problem. A diagnostic procedure that sends a test message back to its origination point.
Loss Of Signal. The T1 line condition where there are no pulses.
Line Signal Detect. An EIA-lead standard for V.24 circuit CT 109; an output signal (DCE-to-DTE).
The device that queries agents for management information, or receives unsolicited SNMP trap messages indicating the occurrence of specific events.
Management Information Base. The set of variables a device running SNMP maintains. Standard, minimal MIBs have been defined, and vendors often have private enterprise MIBs. In theory, any SNMP manager can talk to any SNMP agent with a properly defined MIB. MIB-II refers to an extended management database that contains variables not defined in the original MIB I.
A method for interleaving several access channels onto a single circuit for transmission over the network.
The T1 network interface connector on the rear panel of the DSU/CSU.
Network Management System. A computer system used for monitoring and controlling network devices.
A connection or switching point on the network.
No Signal. A network-reported condition.
A specific item within the Management Information Base (MIB).
Out Of Frame. An error condition in which frame synchronization bits are in error. A network-reported condition.
Out of Service. A digital network trouble signal.
A data network circuit with one control and one tributary device.
Point-to-Point Protocol. A link-layer protocol used by SNMP.
The rules that govern how devices exchange information on a network. It covers timing, format, error control, and flow control during data transmission.
Public Switched Telephone Network. A network shared among many users who can use telephones to establish connections between two points.
Quasi-Random Signal Source. Test pattern that approximates live data that can be monitored for logic errors (on the network and the data port).
A reinitialization of the device that occurs at power-up or in response to a reset command.
Request for Comments. The set of documents that describes the standard specifications for the TCP/IP protocol suite.
Routing Information Protocol. Specifies the routing protocol used between DSUs.
Receive Line Signal Detect. See CD.
A device that makes decisions about the paths network traffic should take and forwards that traffic to its destination. A router helps achieve interoperability and connectivity between different vendor’s equipment, regardless of protocols used.
GL-4 7112-A2-GB20-20 March 1998
Glossary

An EIA standard for the 25-pin DCE/DTE interface. Same as EIA-232.
Request to Send. An EIA-lead standard for V.24 circuit CT 105; an input signal (DTE-to-DCE).
Received Clock. An EIA-lead standard for V.24 circuit CT 115; an output signal (DCE-to-DTE).
Received Data. An EIA-lead standard for V.24 circuit CT 104; an output signal (DCE-to-DTE).
Synchronous Data Link Control. A standard data link protocol.
A test that checks most hardware components when power is applied to the device or a reset is initiated.
Severely Errored Seconds. For T1 data, seconds with 320 or more CRC6 errors or errored frame alignment signals.
Serial Line Internet Protocol. A link layer protocol being used over serial lines by IP.
Simple Network Management Protocol. A generic internet network management protocol that allows the device to be managed by any industry-standard SNMP manager.
An IP addressing standard in which a portion of the host address can be used to create multiple network addresses that are logically a subdivision of the network address.
The subnet portion of an IP address. In a subnetted network, the host portion of an IP address is split into a subnet portion and a host portion using a subnet address mask. This allows a site to use a single IP network address for multiple physical networks.
An integer used with the IP address of the host to determine which bits in the host address are used in the subnet address.
Data transmission that is synchronized by timing signals. Characters are sent at a fixed rate.
Transmission Control Protocol/Internet Protocol. Refer to IP.
Time Division Multiplexer. A device that enables the simultaneous transmission of multiple independent data streams into a single high-speed data stream.
Virtual terminal protocol in the Internet suite of protocols. Allows the user of one host computer to log into a remote host computer and interact as the user for that host.
The allocated DS0 channel slot when DS0 channels are combined to form an aggregate bit stream.
Test Mode. An EIA-lead standard for V.24 circuit CT 142; an output signal (DCE-to-DTE).
A notification message to the SNMP manager when an unusual event occurs on a network device, such as a reinitialization.
Transmit. To send signals from a device.
Transmit Clock. An EIA-lead standard for V.24 circuit CT 114; an output signal (DCE-to-DTE).
Transmit Data. An EIA-lead standard for V.24 circuit CT 103; an input signal (DTE-to-DCE).
A wideband digital interface operating at 1.544 Mbps.
Unavailable Seconds. A count of 1-second intervals when service is unavailable.
User Datagram Protocol. An Internet protocol.
GL-5 7112-A2-GB20-20 March 1998
Glossary

A CCITT standard for a low-speed, 25-position, DCE/DTE interface.
ITU-T standard for a high-speed, 34-pin, DCE/DTE interface.
A CCITT standard for local and remote diagnostic loopback tests.
Wide Area Network. A network that operates over long distances and spans a relatively large geographic area (e.g., a country).
An outgoing signal transmitted when a DS1 terminal has determined that it has lost the incoming signal.
A test pattern consisting of a one (1) followed by seven zeros (on the network only).
A pseudo-random bit sequence that is 511 bits long (on the data ports only).
GL-6 7112-A2-GB20-20 March 1998
Glossary

EER (Excessive Error Rate)
identity, 3-1 installing rear connectors. See Start-Up Instructions interface connections, 1-4 invert transmit clock, A-8 IP address, Ethernet port, A-11 IP addresses, 4-7, 5-1 IP interfaces, 4-1, 5-2
LED, 6-4 status message, 6-7 effective access level, 4-5 EIA-232 pin assignments, E-3 ending an ATI session, 2-7 enterprise
MIB objects, C-29 SNMP traps, D-4 environmental specifications, F-1 Ethernet cable, E-3 Ethernet port
connector, E-3 default gateway address, A-12 IP address, A-11 IP subnet mask, A-11 options, A-11 Use, A-11 Ethernet-Like MIB
LADS connection distances. See Start-Up Instructions lamp test, 7-12 LAN cable, E-3 LEDs, 1-3, 6-2 Line Build Out, A-4 line coding format, A-3 line framing format, A-3 link-layer protocols, 5-1 local line loopback (LLB), 7-4 login ID, 4-1
objects not supported, C-20 objects supported, C-20 external device, access, 4-1 external modem interface, E-4
terminal port requirement, A-13 LOS (Loss Of Signal), status message, 6-7
Facility Data Link (FDL), configuration option, A-4 Facility Data Link IP Addressing, configuration option,
A-4, A-5 factory default configuration options, resetting, 4-3 factory defaults, 3-2 FAIL, LED, 6-3 FDL
main menu, 2-2, A-1 management port
access, 4-1 location, 1-4 Management Protocol Statistics, 6-15 Memory Fail, status, 6-8 messages
configuration option, A-4 subnet connection, 5-3, 5-4 FDLIP, configuration option, A-4, A-5 features, 1-1 framing, A-3 front panel, status indicators, 1-3
alarm and device, 8-1 health and status, 6-7 self-test results, 6-8 test status, 6-9 MIB
descriptions, C-1 Ethernet-Like MIB objects supported, C-20 general support, 1-4 monitor test pattern
health and status messages, 6-7
data port, 7-12 network, 7-7 monitoring, 6-1
IN-2 7112-A2-GB20-20 March 1998
Index · keyboard functions, 2-4

R
navigating the screens, 2-4 network
rear panel, 1-4 Refresh command, 6-6 remote line loopback , 7-6 remote send line loopback, 7-6 repeater loopback (RLB), 7-5 resetting
interface cable, E-2 interface options, A-3 interface port location, 1-4 LEDs, 6-4 tests, 7-3 NMS
the access unit, COM port, 4-3 the DSU/CSU, default configuration options, 4-3 restoring, user interface access, 4-3 RFC 1643, object groups supported, C-20 RFCs, MIB descriptions, C-1 RJ48C network interface cable, E-2 router, management data, 5-2 routing information protocol. See RIP RS-232-Like MIB, C-20 RTS, request to send LED, 6-5 RXD, received data LED, 6-5
SNMP access, 4-7 SNMP connectivity, 5-1 SNMP security options, A-17 no test active status message, 6-9
objects for MIBs, C-1 OK, LED, 6-3 OOF (out of frame)
LED, 6-4 performance statistic, 6-12 status message, 6-7 options
safety instructions. See Start-Up Instructions saving option changes, 3-3 screens, for user interface, 2-1– 2-6 security, 4-1 self-test results, 6-8 send FT1 sequence test, 7-11 Send Ones configuration option, A-9 send test pattern
configuration tables, A-1 configuration worksheets, B-1
package checklist. See Start-Up Instructions Passed, status, 6-8 payload loopback (PLB), 7-4 performance statistics, 6-11 physical description of DSU/CSU, F-2 pin assignments, E-1 port, LEDs, 6-5 PORT (1–2) interface, technical specifications, F-2 power input, consumption, F-2 power input connector location, 1-4 power module, F-2 primary clock failed, status message, 6-7 primary clock source, A-3
data port, 7-11 network, 7-6 send V.54 sequence test, 7-10 serial crossover cable, E-4 SIG, network signal LED, 6-4 SNMP
access, 4-6 features, 1-4 setup traps, 8-1 system entries, 3-1 traps, D-1 SNMP & communication, options, A-16 specifications, environmental, F-1 start-up
ATI, 2-1 instructions. See Document 7112-A2-GN10
IN-3 7112-A2-GB20-20 March 1998
Index · QRSS Test, GL-4

statistics, Management Protocol, 6-15 status
cross connect, 6-10 indicators on front panel, 1-3 test messages, 6-9 subnet, IP addresses, 5-1 sync data port options, A-8 system
async terminal, 2-1 how to access, 2-1 resetting/restoring access, 4-3
device name fields, 3-1 LEDs, 6-3
V.35 connector, E-5 V.54 Loop 2. See data channel loopback (DCLB) V.54 Loop 3. See data terminal loopback (DTLB) VT100 compatible terminal. See async terminal
telnet session access, 4-1 telnet session options, A-14 terminal port
weight, F-2 worksheets, option configuration, B-1
access level, A-13 direct connection, 2-1 disconnect time, A-14 inactivity timeout, A-14 terminal port options, A-12 test
yellow alarm action, A-9 Yellow Alarm condition, status message, 6-7
LED, 6-3 status messages, 6-9 Test menu, 7-3 test patterns, 7-6 testing, 7-1 transmit clock inversion, A-8 transmit clock source, A-8 traps, SNMP, 8-1, D-1 troubleshooting, 8-4
performance statistics, 6-11 TXD, transmitted data LED, 6-5
IN-4 7112-A2-GB20-20 March 1998
Index · user interface, 1-3
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Alarm LED is on. | One of several alarm conditions exists. Health and Status displays the alarm condition. | Refer to Table 6-2, Health and Status Messages, for recommended action. | p.74 |
| Fail LED is on. | One of several error conditions exists. Health and Status displays the alarm condition. | Refer to Table 6-2, Health and Status Messages, and Table 6-3, Self Test Results Messages, for recommended action. | p.74 |
| Cannot access the DSU/CSU via the ATI. | The terminal is not set up for the correct rate or data format, or the DSU/CSU is configured so it prevents access. Telnet is not enabled | 1. Check the cable and connections. 2. Set up your terminal or PC emulation as shown in Connecting to the Terminal Port in Chapter 2. 3. Power the DSU/CSU on and off and try again. | p.74 |
| Device Fail appears on the System and Test Status screen under Self-Test results. | The DSU/CSU detects an internal hardware failure. | Select ClrStats from the status menu Contact your service representative. | p.74 |
| No power, or the LEDs are not lit. | The power cord is not securely plugged into the wall receptacle and into the rear panel connection. | Check that the power cord is securely attached at both ends. | p.74 |
| No power, or the LEDs are not lit. | The wall receptacle has no power. | Check the wall receptacle power by plugging in some equipment that is known to be working. Check the circuit breaker. Verify that your site is not on an energy management program. | p.74 |
| No power, or the LEDs are not lit. | Power supply has failed. | Replace power supply. | p.74 |
| An LED is not lit. | LED is out. | Run the Lamp test. If the LED in question does not flash with the other LEDs, then contact your service representative. | p.74 |
| Not receiving data. | The network or data port cables are not connected (check front panel LEDs for more information). A test is being executed on the unit (check the TEST LED on the front panel). The data port is not assigned to the network. The far-end device is off-line. | Check network and data port cables. Run Loopback tests. Refer to Chapter 7, Testing. Stop the test or wait for the test to end. Check the Cross Connect Status screen. If the data port is not assigned to any network timeslots, use the Cross Connect Assignment screen (under the Config menu) to connect the port to the network. Make sure the far-end device is on. | p.75 |
| Power-Up Self-Test fails. Only Fail LED is on after power-up. | The DSU/CSU has detected an internal hardware failure. | Select ClrStats from the status menu Contact your service representative. | p.75 |