3921P LUS
INSTALLATION AND OPERATION
MANUAL
November 1996

4th Edition (November 1996)
Changes and enhancements to the product and to the information herein will be documented and issued as a new release or a Firmware Update Description document to this manual.
For the Model 3920Plus standalone modems, the Universal Service Order Code (USOC) for Permissive mode is RJ11C. The Canadian equivalent to RJ11C is CA11A. For the 3921Plus carrier-mounted modems, the USOC for Permissive mode is RJ21X. The Canadian equivalent to RJ21X is CA21A.
For regulatory approval, refer to the product labeling or contact your local representative.
Contact your sales or service representative directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, or training, use one of the following methods:
— Within the U.S.A., call 1-800-870-2221 — International, call 727-530-2340
All products and services mentioned herein are the trademarks, service marks, registered trademarks or registered service marks of their respective owners.
Printed on recycled paper
COPYRIGHT 1996 Paradyne Corporation. All rights reserved.
This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Avenue North, P.O. Box 2826, Largo, Florida 33779-2826.
Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.
A November 1996 3920-A2-GN31-30

Prior to installation, use an outlet tester or a voltmeter to check the ac receptacle for the presence of earth ground. If the receptacle is not properly grounded, the installation must not continue until a qualified electrician has corrected the problem.
If a three-wire grounding type power source is not available, consult a qualified electrician to determine another method of grounding the equipment.
In addition, if the equipment is to be used with telecommunications circuits, take the following precautions:
– Never install telephone wiring during a lightning storm. – Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. – Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. – Use caution when installing or modifying telephone lines. – Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. – Do not use the telephone to report a gas leak in the vicinity of the leak.
B 3920-A2-GN31-30 November 1996
Safety Instructions

C November 1996 3920-A2-GN31-30


1-1 Model 3920Plus Standalone Singleport and Multiport Modems 1-3 1-2 Model 3921Plus Singleport Modem 1-5 1-3 Model 3921Plus Multiport Modem 1-6 2-1 Model 3920Plus Multiport Back Panel and Power Supply 2-4 2-2 Modem’s Back Connector Plates 2-7 2-3 Installing the Model 3921Plus Modems 2-8 2-4 Circuit Pack Lock 2-10 3-1 Model 3920Plus DCP 3-3 3-2 Optional SDCP and Model 3921Plus Faceplate 3-4 3-3 392xPlus LCD and Keypad 3-7 3-4 Local Analog Loopback 3-57 3-5 Remote Digital Loopback 3-58 3-6 Local Digital Loopback 3-60 3-7 Pattern Test and Local Analog Loopback Test 3-61 3-8 Pattern Test and Digital Loopback Test 3-62 3-9 End-to-End Pattern Test 3-62 3-10 Dial Backup 3-68 4-1 DCP Configuration Process 4-2 C-1 VF Pin Orientation C-3 C-2 Wiring Diagram — “Y” Cable for External Telephone C-4 C-3 Wiring Diagram — 8-Position to 6-Position Crossover Cable C-5 C-4 Wiring Diagram — 25-Pin Crossover Cable C-6 G-1 Sample Configuration — Point-to-Point G-2 G-2 Sample Configuration — Extended Point-to-Point G-4 G-3 Sample Configuration — Extended Multipoint G-6 G-4 Sample Configuration — Point-to-Point with Automatic Dial Backup G-8 G-5 Sample Configuration — Point-to-Point with Network Management G-10 G-6 Sample Configuration — Carrier with Network Management G-12 G-7 Sample Configuration — Extended Diagnostics G-14 G-8 Sample Configuration — Digital Bridge G-16 G-9 Sample Configuration — Point-to-Point MSD G-18 G-10 Sample Configuration — Multipoint MSD G-20
iii 3920-A2-GN31-30 November 1996
Table of Contents

1-1 392xPlus Operational Modes 1-7 1-2 Technical Specifications for 392xPlus Modems 1-13 3-1 392xPlus DCP LEDs 3-5 3-2 SDCP LEDs 3-6 3-3 Top-Level Menu Status 3-11 3-4 Common Operational Messages 3-14 3-5 Dial Access Security Messages 3-14 3-6 Health and Status Messages 3-18 3-7 Backup Status Screens 3-27 3-8 Valid Ranges for VF Thresholds 3-53 3-9 Valid Dial Command Modifiers 3-72 4-1 DTE Interface Configuration Options — Multiport Mode 4-10 4-2 Line Dialer Configuration Options — Multiport Mode 4-19 4-3 Dial Line Configuration Options — Multiport Mode 4-22 4-4 Leased Line Configuration Options — Multiport Mode 4-24 4-5 Test Configuration Options — Multiport Mode 4-27 4-6 Miscellaneous Configuration Options — Multiport Mode 4-28 4-7 DTE Interface Configuration Options — Singleport Mode 4-33 4-8 DTE Dialer Configuration Options — Singleport Mode 4-41 4-9 Line Dialer Configuration Options — Singleport Mode 4-46 4-10 Dial Line Configuration Options — Singleport Mode 4-50 4-11 Leased Line Configuration Options— Singleport Mode 4-53 4-12 V.42/MNP/Buffer Configuration Options — Singleport Mode 4-58 4-13 Test Configuration Options — Singleport Mode 4-64 4-14 Miscellaneous Configuration Options — Singleport Mode 4-66 5-1 Result Codes 5-3 5-2 392xPlus AT Commands 5-6 5-3 392xPlus S-Registers 5-16 6-1 Edit Password Table Group Options 6-8 6-2 Set Answer Security Group Options 6-9 6-3 Set Originate Security Group Options 6-10 6-4 Security Configuration Options 6-13 6-5 Security Database Table Using VF-Side Passwords 6-16 6-6 Security Database Table Using DTE-Side Passwords 6-17 6-7 Security Database Table Using Both VF-Side and DTE-Side Passwords 6-17 B-1 Modem Health B-1 B-2 Leased-Line Operation B-2 B-3 Dial Backup Operation B-2 B-4 Modem — DTE Connection B-3 B-5 Modem — VF Connection B-4
iv November 1996 3920-A2-GN31-30

B-6 Online Operation B-5 B-7 Mux Operation B-5 C-1 EIA-232-D Pin Assignments C-2 C-2 VF Connector Pin Assignments C-3 D-1 V.25bis Commands D-6 D-2 V.25bis Response Messages D-7 E-1 ASCII Characters E-1 F-1 Factory Default Configuration Options F-2
v 3920-A2-GN31-30 November 1996
Table of Contents

Objectives and Reader Assumptions
This manual describes how to install and operate the COMSPHERE Model 3920Plus standalone and Model 3921Plus carrier-mounted modems. Users of this manual must have a basic understanding of modems and their operation.
Chapter 1 provides technical specifications, information about the four 392xPlus models, the modem features, and the government requirements for using these modems.
Chapter 2 provides instructions for installing the 392xPlus modems.
Chapter 3 provides the information required to operate the Model 3920Plus using the diagnostic control panel and the Model 3921Plus using the COMSPHERE 3000 Series Carrier’s shared diagnostic control panel (SDCP).
Chapter 4 provides the information required to set configuration options in the 392xPlus modems using the modem’s diagnostic control panel.
Chapter 5 provides instructions for using AT commands and S-Registers.
Chapter 6 provides instructions for using the Dial Access Security feature.
Appendix A provides a menu tree for the 392xPlus modems.
Appendix B provides instructions for performing diagnostic tests when data communication problems occur.
Appendix C provides EIA-232-D and VF TELCO pin assignments.
Appendix D provides V.25bis dialing information.
Appendix E provides an ASCII translation chart.
Appendix F provides a list of all default configuration options available for the factory preset configurations.
Appendix G provides diagrams of sample configurations for the 392xPlus modems.
Appendix H provides an equipment list for the 392xPlus modems.
The Glossary provides a description of terms used throughout this manual.
vii 3920-A2-GN31-30 November 1996

3000-A2-GA31 COMSPHERE 3000 Series Carrier, Installation Manual
3610-A2-GZ45 3600 Hubbing Device, Feature Number 3600-F3-300, Installation Instructions
3920-A2-GK41 COMSPHERE 392xPlus Modems, Models 3920Plus and 3921Plus, Installation Instructions
3920-A2-GK40 COMSPHERE 3900 Series Modems, Model 3921Plus, Ferrite Choke Installation Instructions
Call your sales representative to order additional product documentation.
viii November 1996 3920-A2-GN31-30

Overview 1-1 COMSPHERE 392xPlus Models 1-2 Model 3920Plus Standalone Singleport Modem 1-2 Model 3920Plus Standalone Multiport Modem 1-2 Model 3921Plus Carrier-Mounted Singleport Modem 1-4 Model 3921Plus Carrier-Mounted Multiport Modem 1-4 392xPlus Operational Modes 1-7 392xPlus Features 1-7 392xPlus Singleport Features 1-7 392xPlus Multiport Features 1-8 Applications 1-8 Multipoint 1-8 Dual-Leased Backup 1-8 MSD 1-9 Digital Bridge 1-9 V.34 Modulation 1-9 Multiport Backup 1-10 Government Requirements and Equipment Return 1-11 United States 1-11 Canada 1-12 Technical Specifications 1-13
The COMSPHERE 392xPlus modems are full-feature, high-speed leased modems, providing reliable asynchronous and synchronous operation over leased or dial lines networks with data rates as high as 33,600 bps.
Through downloading capability, any 392xPlus modem is upgradable to the latest firmware, requiring no new hardware investment or on-site personnel, with little or no downtime (refer to Chapter 3, DCP Operations, for more information regarding downloading options). The 392xPlus modems support a wide range of modulation schemes and offer control using either AT commands, the diagnostic control panel (DCP) or the optional COMSPHERE 6700 and 6800 Series Network Management Systems (NMS). The NMS performs extensive monitoring, testing, reporting, and restoral functions to assist in managing your network.
The 392xPlus modems are compatible with a number of dialing methods and protocols, such as asynchronous AT commands, CCITT V.25bis dialing, and the DCP. The DCP allows you to use the 392xPlus modem in a variety of applications and environments while also providing control over modem configuration, dialing, and diagnostics. The 392xPlus modems come with preset factory configurations that are the most often used modem settings.

The COMSPHERE 392xPlus modem is available in the following four models:
The last digit in the model number (x) varies, depending on whether the modem is equipped with fixed Data Access Arrangement (DAA) or configurable DAA.
Throughout this manual, reference to the 392xPlus modem represents all four models.
The Model 3920Plus singleport is a standalone modem (Figure 1-1) capable of either 4-wire/2-wire leased-line or dial operation. This modem is controlled using either AT commands or the DCP. The DCP consists of a liquid crystal display (LCD), three function keys, four directional keys, and a row of 13 LED status indicators. For a better understanding of DCP operation, refer to Chapter 3, DCP Operation.
The Model 3920Plus multiport is a standalone modem (Figure 1-1), with an integral time division multiplexer (TDM) and a modem sharing device (MSD) as standard equipment. The TDM provides time division multiplexing of up to four independent ports over point-to-point lines using the V.34 family or V.32 family modulation. The MSD allows multiple physical ports on a tributary modem to share a single communication channel using the V.34 family, V.32 family, or TMp modulation. The TDM/MSD multiplexer (commonly referred to as “mux” can be enabled or disabled to allow a greater degree of application flexibility.
The 3920Plus multiport modem also operates over a 4-wire/2-wire leased or dial network and is controlled using the same DCP employed on the Model 3920Plus singleport standalone modem.


Multiport Modem Back Panel
DTE 4 POWER ON/OFF
POWER ON/OFF
DTE 3
POWER IN
POWER IN DTE 2
NMS
NMS
DTE 1
DTE 1
DIAL
DIAL
LEASED
496-14684-01 LEASED
Figure 1-1. Model 3920Plus Standalone Singleport and Multiport Modems
Introduction

The Model 3921Plus is a carrier-mounted singleport modem (Figure 1-2) capable of either 4-wire/2-wire leased-line or dial operation. The modem installs into a COMSPHERE 3000 Series Carrier, occupying a single slot. The modem’s faceplate has sixteen (16) LED status indicators for displaying modem activity and an audio speaker jack for the carrier’s optional speaker.
The modem’s back panel has two edge card connectors that mount into a connector plate. This connector plate has two DB-25-S connectors, one providing an EIA-232-D DTE interface and one for future functionality.
The Model 3921Plus is a carrier-mounted multiport modem (Figure 1-3) equipped with an integral time division multiplexer (TDM) with a modem sharing device (MSD). The modem installs into the COMSPHERE 3000 Series Carrier, occupying two slots. The modem’s faceplate covers two slots in the carrier. It has twenty (20) LED status indicators for displaying modem activity and an audio speaker jack for the carrier’s optional speaker.
The modem’s back panel has four edge card connectors that mount into two connector plates. Each connector plate has two DB-25-S connectors providing four EIA-232-DTE interfaces.
Both the singleport and multiport Model 3921Plus modems derive ac power from the COMSPHERE 3000 Series Carrier’s backplane, which is a common bus to all devices installed in the carrier. The user interface to any Model 3921Plus modem is through the shared diagnostic control panel (SDCP), an optional feature which operates in a manner similar to the DCP on the Model 3920Plus modems. For a better understanding of DCP operation, refer to Chapter 3, DCP Operation.


PLATE
EIA232/V.24 CONNECTOR
RS366A/V.25 (3800) EIA232/V.24
GROUNDING
TAB
FUTURE
V.35 (3600/3500)
USE
Figure 1-2. Model 3921Plus Singleport Modem
Introduction · 496-14178a-04



The 392xPlus operational modes determine how your modem performs in various applications. These operational modes are determined by your modem model and the selected configuration options.
There are two operational modes:
Using Table 1-1, identify your modem’s operational mode based on the 392xPlus modem model and its selected MUX mode configuration option.
392xPlus Modem MUX Mode Configuration Option Operational Mode
Use the identified operational mode (Singleport or Multiport) to choose the configuration options that are appropriate for your application. Refer to Chapter 4, DCP Configuration for more information on configuration options.
The 392xPlus modems share a wide variety of features.

Features specific to 392xPlus singleport modems are:
Refer to Table 1-2 in the Technical Specifications section of this chapter for leased- and dial-line modulations information.
Features specific to 392xPlus multiport modems are:
Multipoint is available in all 392xPlus modems. It utilizes leased-line circuits for time sharing the same front-end processor (FEP) port with multiple remote locations. The FEP (via the control modem) regulates traffic on the line by continuously polling the tributary DTE(s) in a predefined sequence. Only one tributary can communicate with the control modem at a given time. Modems configured for Trellis Multipoint (TMp) cannot be used in a point-to-point, constant carrier application. (Refer to the Multiport Mode — Leased Line or the Singleport Mode — Leased Line section in Chapter 4 for configuration options.)

Dual-Leased Backup is available in all 392xPlus modems. It enables a 2-wire leased line to be used as the backup facility instead of the normal 2-wire dial line. Plug the leased line into the jack labeled DIAL on the back panel of the modem (see Figure 2-1 in Chapter 2), and enable the Dual_Leased_Ln configuration option. (Refer to the Multiport Mode — Leased Line or the Singleport Mode — Leased Line section in Chapter 4 for configuration options.) Except for dialing, ring indication, and call progression functions, you control the backup function as if it were a normal dial backup.
The Modem Sharing Device (MSD) is only available in 392xPlus multiport modems. It allows from 2 to 4 physical ports to share a communication channel. When the MUX mode option is set to TDM/MSD on a tributary, and at least one port has the MSD mode setting enabled, then MSD is enabled. For more information, refer to the Multiport Mode section of Chapter 4 for configuration options or the Point-to-Point MSD and Multipoint MSD sample configurations in Appendix G.
When MSD mode is enabled:
The Digital (DTE) Bridge application is only available in 392xPlus multiport modems. It provides the ability for dial backup of a multipoint configuration by bridging the signal on the digital side of the FEP-end modems. In this configuration, only two ports (both on the FEP side) are used on the control and backup modems. Data received on Port 1 is transmitted across the communication link, as well as looped back out of Port 2. Data received across the communication link and on Port 2 is sent out of Port 1. For more information, refer to the Multiport Mode section of Chapter 4 or the Digital Bridging sample configuration in Appendix G for sample configurations.
When the Digital Bridge is enabled, a new menu is present with the following conditions:
The V.34 modulation capability is available in all 392xPlus modems. In Singleport mode the V.34 modulation is compatible with other vendors’ modems that support the CCITT V.34 modulation. The two top rates of 31,200 and 33,600 bps (Paradyne), however, only function with other 392xPlus modems. In Multiport mode, the V.34 modulation will not operate at line rates of 31,200, 26,400, and 21,600 bps, and is only compatible with other 392xPlus modems.
Introduction

The CCITT standard for V.34 modulation includes dial- or leased-line operation. For proper leased-line operation, one modem must be designated as the answer modem while the other modem must be designated as the originate modem.
The V.34 standard also includes asymmetric rates, automatic adjustment of the transmit power level, and automatic adjustment of the symbol (baud) rate for optimal data throughput. These automatic adjustments are made during the training, or modem synchronization, phase via special line-probing techniques that establish the top-most viable rate of operation. Due to these techniques, true fixed-rate operation of the modems using V.34 modulation is not possible, since the line condition may not be capable of supporting the selected rate. Thus, using CT111 and CT112 for rate control of extended data circuits cannot be used.
When operating in V.34 modulation, you can use the top line of the Quick Configuration screen to view the current modem transmit rate, the symbol or baud rate, and the transmit level. The 392xPlus modems offer separate options for leased and dial lines to override the asymmetric rate function, since this can cause problems for certain DTE equipment, Also, each symbol rate supports a subset of data rates, which make up the whole of the V.34 standard.
3429 4800 – 33.6K
3200 4800 – 31.2K
3000 4800 – 28.8K
2800 4800 – 31.2K
2743 4800 – 31.2K
2400 2400 – 24.0K
When using the V.34 modulation on leased lines with a 2-wire leased backup facility, the backup line check feature, which tests the backup leased lines for connectivity, cannot be used.
When a 2400 V.34 modulation connection occurs on one end of a modem pair with configuration options set for Asymmetric rates, the other modem is 24K due to the 2400 symbol rate it uses.
When the 392xPlus multiport modem has the MUX mode configuration option set to either TDM/MSD or Digital Bridge, it is in Multiport mode, and either dial lines or a 2-wire leased line can be used to back up the primary 4-wire leased line. Backup can be performed automatically upon loss of the primary leased line, and automatic dial standby also can be used to automatically return the modems to the primary leased line when restored.
When you use backup functions while in Multiport mode, the modem’s automode feature is forced to Disable. This ensures that the mux is not accidentally disabled by answering a call, which is using modulation where Multiport mode is not supported. It is important that both modems participating in the backup are in Multiport mode with the same dial-line modulation.

Certain governments require that instructions pertaining to modem connection to the public switched telephone network be included in the installation and operation manual. Specific instructions are listed in the following sections.
NOTICE T O USERS OF THE PUBLIC SWITCHED TELEPHONE NETWORK
4. The ringer equivalence (REN) is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the telephone company to determine the maximum RENs for the calling area.
Introduction

— Within the U.S.A., call 1-800-870-2221
— International, call 727-530-2340
If the trouble is causing harm to the telephone network, the telephone company may request that you remove the equipment from the network until the problem is resolved.
NOTICE TO THE USERS OF THE CANADIAN PUBLIC SWITCHED TELEPHONE NETWORK
The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone line and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
The Load Number is labeled on the equipment. The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all devices does not exceed 100.
If your equipment is in need of repair, refer to the procedure in the Government Requirements and Equipment Return section.

Table 1-2 shows the technical specifications for the 392xPlus modems.
Specifications Description
APPROVALS
Model 3920Plus, 3921Plus, and COMSPHERE 3000 Series Carrier
Refer to the product labeling or contact your service representative.
COMPATIBILITY Leased-Line Modulations:
Paradyne V.34 (33,600, 31,200 bps) CCITT V.34 (28,800, 26,400, 24,000, 21,600, 19,200, 16,800, 14,400,
12,000, 9600, 7200, 4800, 2400 bps) Paradyne V.32 terbo (19,200, 16,800 bps) CCITT V.32bis (14,400, 12,000, 9600, 7200, 4800 bps) CCITT V.32 (9600, 4800 bps) Paradyne Trellis Multipoint (19,200, 14,400, 9600, 7200, 4800,
2400 bps) CCITT V.22bis (2400 bps) CCITT V.27bis (4800, 2400 bps) CCITT V.33 (14,400, 12,000 bps) CCITT V.29 (9600, 7200, 4800 bps) Paradyne Point-to-Point Diagnostic (2400 bps)
Dial-Line Modulations:
Paradyne V.34 (33,600, 31,200 bps) CCITT V.34 (28,800, 26,400, 24,000, 21,600, 19,200, 16,800, 14,400,
12,000, 9600, 7200, 4800, 2400 bps) Paradyne V.32 terbo (19,200, 16,800 bps) CCITT V.32bis (14,400, 12,000, 9600, 7200, 4800 bps) CCITT V.32 (9600, 4800 bps) CCITT V.22bis (2400 bps) CCITT V.22 (1200 bps) CCITT V.23 (1200, 600 bps) CCITT V.21 (300 bps) Bell 212A (1200 bps) Bell 103J (300 bps) Paradyne Point-to-Point Diagnostic (2400 bps)
Operating Temperature 32°F (0°C) to 122°F (50°C)
Relative Humidity 5% to 90% (noncondensing)
Shock and Vibration Withstands normal shipping
Storage Temperature –4°F (–20°C) to 158°F (70°C)
25-pin D-subminiature connector EIA-232-D/CCITT V.24
MODEL 3920Plus POWER SUPPLY AC POWER REQUIREMENTS
100 to 250 Vac, 50 to 60 Hz
Introduction

Specifications Description
POWER CONSUMPTION
Model 3920Plus Singleport 6 watts (typical, including power supply, speaker off)
Model 3921Plus Singleport 4 watts (typical, each card) (Speaker consumption is approximately 1 watt at high volume.)
Model 3920Plus Multiport 8 watts (typical, including power supply, speaker off)
Model 3921Plus Multiport 6 watts (typical, each card) (Speaker consumption is approximately 1 watt at high volume.)
Weight 2.5 pounds (1.14 kg) Model 3920Plus (without power supply) 1.0 pounds (0.45 kg) Model 3921Plus
Height 2.1 inches (5.4 cm) Model 3920Plus 7.1 inches (18.1 cm) Model 3921Plus
Width Singleport 7.6 inches (19.4 cm) Model 3920Plus 0.9 inches (2.3 cm) Model 3921Plus Multiport 7.6 inches (19.4 cm) Model 3920Plus 1.8 inches (4.6 cm) Model 3921Plus
Depth 12.1 inches (30.8 cm) Model 3920Plus 13.4 inches (34.0 cm) Model 3921Plus
Leased Line (North America) 0 through –15 dBm (in 1 dBm decrements) Factory default is 0 dBm
Leased Line (All Other Countries) –1 through –15 dBm (in 1 dBm decrements) Factory default is country dependent
Dial Line (North America) –10 through –32 dBm (in 1 dBm decrements) Factory default is Permissive (–9 dBm)
Dial Line (All Other Countries) Level setting is not accessible to the user Factory default is country dependent
Leased-Line Connectivity JM8 (Model 3920Plus ) 50-pin mass termination (Model 3921Plus )
Dial-Line Connectivity RJ11C Permissive RJ21X Permissive 50-pin connector (Model 3921Plus )
Leased Line 33,600, 31,200, 28,800, 26,400, 24,000, 21,600, 19,200, 16,800, 14,400, 12,000, 9600, 7200, 4800, 2400 bps
Dial Line 33,600, 31,200, 28,800, 26,400, 24,000, 21,600, 19,200, 16,800, 14,400, 12,000, 9600, 7200, 4800, 2400, 1200, 600, 300 bps
DATA COMPRESSION CCITT V.42bis MNP Class 5

Overview 2-1 392xPlus Modem Package 2-1 Customer-Supplied Equipment 2-2 Model 3920Plus Modem Installation 2-3 Connecting Cables to the Model 3920 Modem 2-3 DTE Connection 2-4 Power Supply Connection 2-5 Leased-Line Connection 2-5 Dial Connection 2-5 Leased Backup Connection 2-5 Dial Backup Connection 2-5 Network Management System Connection 2-6 Removing and Replacing the Model 3920Plus Modem 2-6 Model 3921Plus Modem Installation 2-6 Removing and Replacing the Model 3921Plus Modem 2-11 392xPlus Modem Power-Up 2-11 Selecting Factory Configuration Options for 392xPlus 2-11 Using the Diagnostic Control Panel (DCP) 2-12
This chapter provides a list of equipment supplied with 392xPlus modems, as well as a list of customer supplied equipment. In addition, it describes how to install and remove the 392xPlus modems, and how to select a factory preset configuration using the DCP.
After opening the modem’s package, check for damage and verify that the following items are present:

If any hardware components are damaged, notify your service representative. Return equipment using the procedures described in the Government Requirements and Equipment Return section of Chapter 1.
The following customer-supplied equipment is required to complete a data communications system using the Model 3920Plus modem:
— JM8 for leased-line configurations.
— RJ11C for dial permissive configurations.
— One 8-position, 8-wire modular cord (for leased backup purposes).
The following customer-supplied equipment is required for the installation of a Model 3921Plus modem:
— RJ11C for single-line dial permissive configurations.
— RJ21X for multiple-line dial permissive configurations.
— 66 punchdown block.
For installation of the COMSPHERE 3000 Series Carrier into a cabinet, refer to the COMSPHERE 3000 Series Carrier, Installation Manual.

Before installing your standalone modem, make sure your installation site is clean and well-ventilated. Allow space around the modem for installing cables and telephone cords, and make sure the modem is located within reach of the ac power outlet. The distance between your modem and DTE should be minimized if DTE data rates exceed 19,200 bps. Also, low capacitance cables may be necessary for speeds greater than 19,200 bps or distances greater than 50 feet.
The back panel of the Model 3920Plus modem (Figure 2-1) has the following switches and connectors:
Instructions for connecting cables to the TELCO jack types using the appropriate cables apply to both singleport and multiport Model 3920Plus modems. Figure 2-1 illustrates the Model 3920Plus multiport modem. For pin assignments, refer to Appendix C.
Modem Installation


NETWORK OPERATION
DTE Connection
Use the following steps to connect an EIA-232-D cable from the modem to a DTE:

Use the following steps to connect the modem to an ac power outlet:
Use the following steps to connect the leased-line network interface:
The telephone company provides the line termination jacks for the permissive service you request. Advance coordination with the telephone company is suggested when connecting the modem to telephone dial lines (PSTN).
In the Permissive mode, the modem’s transmit output level is fixed at –9 dBm. The telephone company assumes that the line loss is 3 dB and no compensation is provided for additional losses. A Permissive mode telephone line is usually terminated with a USOC RJ11C jack.
Use the following steps to connect the modem to the 2-wire leased backup network interface:
Use the following steps to connect the modem to the dial network interface:
Modem Installation

Use the following steps to connect the modem to the network management system (NMS) interface:
To remove and replace the Model 3920Plus modem, perform the following steps:
If the modem is to be removed for service, return it to the company using the procedures described in Government Requirements and Equipment Return in Chapter 1.
When removing the Model 3921Plus from the carrier, always use a ground strap when handling the modem. Always store the Model 3921Plus in an antistatic bag when it is removed from the carrier.
The Model 3921Plus modems are designed for installation in a COMSPHERE 3000 Series Carrier, which supplies both the operating power and the leased and/or dial network connections. For additional information about the COMSPHERE 3000 Series Carrier, refer to the COMSPHERE 3000 Series Carrier, Installation Manual.
The COMSPHERE 3000 Series Carrier has 17 slots that hold up to 8 Model 3921Plus multiport modems or 16 Model 3921Plus singleport modems, and one shared diagnostic unit (SDU). The

SDU is required when the modems in the carrier are controlled by an NMS, or when multiple carriers in a cabinet configuration are to be controlled by a single shared diagnostic control panel (SDCP). The SDCP of the COMSPHERE 3000 Series Carrier is the user interface to the Model 3921Plus modem. A single SDCP can control up to eight carriers.
The installation of a Model 3921Plus modem varies slightly if an SDCP is installed on the front of the carrier. To install a Model 3921Plus modem into the carrier without an SDCP, perform the following steps:
Loosely fasten the plate(s). This allows for slight adjustments later when installing the modem.
Slide the modem into the slot, aligning the modem with the connector plates, until the backplane connector and DTE connector seat firmly into the back of the carrier. The faceplate latch automatically closes as you push the modem into the carrier. To lock the modem into the carrier, press the faceplate latch until a “click” is heard.
Return to the back of the carrier and tighten the connector plate(s).
SINGLEPORT
BACK CONNECTOR PLATES
BACK CONNECTOR PLATE

EIA232/V.24 CONNECTOR
V.35 (3600/3500)
FUTURE USE
Figure 2-2. Modem’s Back Connector Plates
Modem Installation · 495-14696


SINGLEPORT
MODEM
GUIDES

MULTIPORT
MODEM
Figure 2-3. Installing the Model 3921Plus Modem
MODEL 3921Plus · MODEL 3921Plus

If the Model 3921Plus modem is to communicate with an installed SDCP, install the modem as described above and perform the following steps:
Carr:Slot: 1:01A ↑ ↓ 1:01A
F2 F3
Carr:Slot: 1:01A ↑ ↓ 1:01A
F2 F3
The carrier number selection has a range of 1 to 8 since a single SDCP can control a configuration of up to eight carriers. (This is only possible if the SDU is installed.)
The LCD displays the Top-Level menu for the selected modem. In addition, the Front Panel LED on the modem’s faceplate and the OK LED on the SDCP light.
Modem Installation

PACK LOCK
LATCH
OPEN CLOSED
RELEASE TAB
Figure 2-4. Circuit Pack Lock
495-14425-02

When removing the Model 3921Plus modem from the carrier, always use a ground strap when handling the modem. Always store the Model 3921Plus modems in an antistatic bag when it is removed from the carrier.
It is not necessary to power down the carrier to remove and replace the Model 3921Plus modem. Perform the following steps:
Once your modem is properly connected to the power supply, leased and/or dial lines, and the DTE, press the modem’s back panel power switch to the ON position. The modem begins a power-up self-test, in which all DCP LEDs light. This test takes several seconds to perform, and verifies the operation of most hardware components within the modem. If successful, the LCD displays Power on Selftst Passed and continues to the Top-Level menu screen.
Power On Selftst Passed
F2 F3
If a failure occurs during the self-test, the LCD displays Power On Selftst Failed for several seconds. The LCD then displays the Top-Level menu screen with the message Power on Fail appearing on the top line of the LCD. Although a failure has occurred, the modem will attempt to operate. This allows you to activate a more thorough self-test using the Test branch. Refer to the Test section in Chapter 3.
After the modem passes the power-up self-test, configure it for operation using one of the six factory preset configurations.
The 392xPlus modems have six factory preset templates that contain the most commonly used configuration options (straps) for Synchronous Leased (Answer or Originate), Asynchronous Leased (Answer or Originate), Trellis Multipoint (Control or Tributary), Asynchronous Dial, Synchronous Dial, and UNIX Dial hardware network configurations. Your modem ships from the factory with the Synchronous Leased (Answer) default configuration options stored in memory. If Synchronous Leased (Originate), Asynchronous Leased (Answer or Originate), Trellis Multipoint (TMp) (Control or Tributary), Async Dial, Sync Dial, or UNIX Dial is more appropriate for your
Modem Installation

configuration, then you must change the factory setting using either the modem’s DCP (as described in the following sections) or the AT command set.
The purpose of having preset configurations is so that you can have a “head start” in getting your modem operating and reducing the amount of time required to configure your modem. For a better understanding of DCP operation and factory preset configuration options, refer to Chapter 4, DCP Configuration.
The DCP’s liquid crystal display (LCD) consists of two 16-character lines which display modem status, control functions, and configuration options as well as indicating your location in the Top-Level menu tree (Appendix A).
To change a factory template from the Sync Leased preset configuration using the DCP, perform the following steps:
The LCD now displays Ld EditArea frm.
Factory preset configurations are Sync Leased, Async Leased, TMp (Trellis Multipoint), Async Dial, Sync Dial, and UNIX Dial. If Sync Leased or Async Leased is selected, you must choose either Answer or Originate mode. If TMp is selected, you must choose either Control or Trib (Tributary) mode.
(These three configuration areas are nonvolatile memory locations. Active (Saved) contains the most recently saved changes to any configuration options. In the event of power loss, the modem retrieves these configuration options. Customer 1 and Customer 2 are user-defined configuration areas.)
The LCD now displays Sav EditArea to.
Refer to Chapter 4, DCP Configuration, for more information regarding default factory configuration options.

Overview 3-2 Diagnostic Control Panels 3-2 Model 3920Plus Diagnostic Control Panel 3-3 Model 3921Plus Faceplate and Shared Diagnostic
Control Panel (SDCP) 3-3 Status Indicators 3-3 Diagnostic Control Panel Operation 3-7 LCD Display 3-7 Hidden Choice Indicators 3-7 Other Indicators 3-8 Keypad 3-8 Menu Structure 3-9 Top-Level Menu Status and Operational Messages 3-11 Quick Configuration Display 3-15 Status Branch 3-17 Device Health and Status (DeviceHS) 3-18 VF 3-20 Displaying VF Conditions 3-21 Clearing VF Counters 3-22 Identity 3-23 DTE 3-24 V.34 3-25 Backup 3-26 Options 3-28 Record 3-28 Service Log 3-29 Configure Branch 3-30 Poll List Branch 3-30 Display 3-31 Clear 3-32 Change 3-32 Add 3-33 Acquire 3-34 Control Branch 3-35 Speaker 3-36 Reset 3-37 Data Stream 3-37 Selecting All Ports 3-38 EIA LEDs 3-39 Make Busy/Remove Make Busy 3-40 Service Line/Disconnect Service Line 3-41 Download Software 3-42 Selecting Clone Remote 3-42 Clone Remote in Point-to-Point Configurations 3-43 Clone Remote in Broadcast Configurations 3-43 Clone Remote in Multipoint Configurations 3-45 Implementing a Clone Remote Operation 3-48 Automatic Firmware Download 3-50 Automatic Firmware Download Failure 3-50 VF Thresholds Update 3-51

Test Branch 3-54 Abort 3-55 Self 3-56 Loc Analog Loop 3-57 Rem Digital Loop 3-58 Loc Digital Loop 3-60 Pattern 3-61 Sub-Network Health and Status Branch 3-64 Call Setup Branch 3-65 Dial 3-66 Disconnect 3-67 Answer 3-68 Dial Standby/Return to Dial 3-68 Change Directory 3-70 Entering Telephone Numbers and Dial Command Modifiers into
Directory Locations 3-71 Directory Status (Does Not Appear in North America) 3-72 Talk/Data Branch 3-73 Manual Dialing When the Remote Modem is Configured for
Auto-Answer 3-74 Manual Dialing When the Remote Modem is Configured for
Manual Answer 3-75 Security Branch 3-75 Remote Branch 3-76 Diagnostic Control Panel Access 3-80
This chapter describes how to use the diagnostic control panel (DCP) of the 392xPlus modem. It also describes how to select and use each branch of the Top-Level menu tree.
There are two types of diagnostic control panels (DCP), the DCP on the standalone Model 3920Plus modems and the shared diagnostic control panel (SDCP), an optional feature, used with the Model 3921Plus installed into a COMSPHERE 3000 Series Carrier. Both DCPs have a two-line, 32-character liquid crystal display (LCD) and keypad through which Top-Level menu branches are accessed to perform the following:
The LCD displays the result of any command initiated using the DCP.

The diagnostic control panel (DCP) of the Model 3920Plus modem (Figure 3-1) contains status indicators, pushbutton-type keys, an LCD, and speaker grill.
PWR ALRM CTS TXD LSD RXD TEST RATE
DIAG DIAL
SQ RTS DTR
105 106 103 109 108 142 COMSPHERE 3920Plus
Model 3921Plus Faceplate and Shared Diagnostic Control Panel (SDCP)
The shared diagnostic control panel (SDCP), Figure 3-2, is used to manage carrier-mounted Model 3921Plus modems.
The faceplate of the Model 3921Plus contains LED status indicators that monitor the operation of the modem. After the SDCP is connected to the modem, the Front Panel indicator of the selected modem lights to show that the modem is connected.
The 392xPlus modem status indicators continuously provide information on the modem’s operating condition. All of the status indicators on the Model 3920Plus appear on the DCP (Figure 3-1), whereas the status indicators for the carrier-mounted Model 3921Plus are located on the Model 3921Plus modem’s faceplate and the SDCP faceplate (Figure 3-2).
The standalone Model 3920Plus modem’s DCP has 13 light-emitting diodes (LEDs), and the carrier-mounted Model 3921Plus has 20 LEDs. These LEDs are listed and described in Table 3-1. LEDs specific to one model type have the appropriate model number shown in the table.
DCP Operation · 496-14412-02


SDU
CARRIER SLOTS 1–16

SDU 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
TEST MODE
Figure 3-2. Optional SDCP and Model 3921Plus Faceplates

Label Color Indicates
Pwr green Power has been applied to the modem.
Alrm red Flashing – A major alarm has been detected in a remote 392xPlus modem.
ON – A major alarm has been detected in the local modem. (For Health and Status alarm conditions, refer to Table 3-6 in the Device Health and Status section of this chapter.)
green The modem is receiving diagnostic communications (either a command or a status poll).
Test/142 yellow Flashing – The modem is involved in a firmware upgrade. Normal operation is not possible.
ON – The modem is involved in a test. Normal operation is not possible.
OFF – The modem is not involved in a test or firmware upgrade.
Dial yellow Flashing – The modem is attempting to establish a call over the dial network, or the modem is in Dial Standby mode.
ON – The modem has established a dial connection.
OFF – A dial connection does not exist.
green A ringing signal is being received.
yellow The modem is placed in a forced busy condition and is off-hook.
yellow The modem’s dial line is connected to the carrier service line rather than the normally assigned dial network.
SQ yellow The receive telephone line signal is degraded or the modem’s data path has been blocked (SQ flashes).
yellow ON – The modem is connected at a data rate lower than the data rate it is configured for.
OFF – The modem is connected at its configured data rate.
Front Panel (3921Plus only)
yellow The modem is connected to the carrier’s SDCP.

Label Indicates Color
Port* 1,2,3,4 (3921Plus multiport only)
green ON – The selected port* is one of the mux ports (either 1, 2, 3, or 4).
OFF – The port* is not selected.
TXD/103* green The modem is receiving data from the selected port* to transmit. (ON equals space.)
RXD/104* green Data is being transferred to the selected port*. (ON equals space.)
RTS/105* green RTS signal is ON for the selected port*.
CTS/106* green CTS signal is ON for the selected port*.
green DSR signal is ON for the selected port*.
DTR/108* green The selected port* has turned ON DTR.
LSD/109* green The modem has detected a valid carrier signal and is capable of transferring data to the selected port*.
* The selected port is one of the mux ports (1, 2, 3, or 4) or the Network Management System (NMS) diagnostic interface (3920Plus only). For example, when the selected port is Port 1 of the mux, the EIA indicators for TXD, RXD, RTS, CTS, DSR, DTR, and LSD will indicate the status of the EIA signals on the Port 1 interface of the multiplexer. For information about making this selection, refer to the Control Branch section of this chapter. To display the port which has been selected, refer to the Quick Configuration Display section of this chapter.
The SDCP LEDs are listed and described in Table 3-2.
Label Color Indicates
OK green Power is ON and the modem is capable of operating.
Alarm red The selected modem detects a problem with its operation. For example, the modem failed a self-test.
BckUp yellow The selected modem is operating on the backup network (dial or dual leased).
Test yellow The selected modem is involved in a test. Normal operation is not possible.
EC green The selected modem is in V.42/MNP Error Control mode.
DSR/107* (3921Plus only)

The 392xPlus modem’s diagnostic control panel (DCP) is the user interface to all functions used to configure and control the modem. In addition to the status LEDs, this interface includes the liquid crystal display (LCD) and keypad (Figure 3-3).
INDICATOR
MOVES UP ONE LEVE L F ROM
RETURNS DISPLA Y T O TOP-LEVEL MENU
Leased:28.8 Status Configure
DISPLAY
F1
F2 F3
LEFT SCROLL
RIGHT SCROLL KEY
KEY
FUNCTION KEYS LCD BOTTO M L INE
Figure 3-3. 392xPlus LCD and Keypad
LCD Display
The LCD consists of a top line and bottom line, with each displaying a maximum of 16 characters at a time. If more information is available on the LCD than what is currently displayed, a hidden choice indicator ( < , , or > ) appears in the upper right-hand corner of the LCD. Use the or key to scroll in the indicated direction to display more selections onto the LCD.
The Hidden Choice Indicators serve as an alert that other selections are available besides what is currently displayed on the LCD. These indicators appear as one of the following symbols:
The right scroll indicator appears when more choices are available to the right of what is currently displayed on the LCD.
The left/right scroll indicator appears when more choices are available to the left and right of what is currently displayed on the LCD.
The left scroll indicator appears when more choices are available to the left of what is currently displayed on the LCD.
DCP Operation · Hidden Choice Indicators

Other indicators may turn on depending on existing conditions, such as error detection, informational alerts, and warnings. These indicators appear on the top or bottom line of the LCD.
If the local 392xPlus modem establishes a connection with the remote 392xPlus modem via the Remote branch, then appears in the upper right corner of the LCD top line on both modems. For more information on the Remote Mode indicator, refer to Remote Branch in this chapter.
Out of Range Indicator
If an invalid threshold (out of range) is selected in the VF Threshold update process, then appears in the lower right corner of the LCD bottom line. For more information on the Out of Range indicator, refer to VF Thresholds Update in this chapter.
The DCP on the Model 3920Plus has seven keys while the optional SDCP of the COMSPHERE 3000 Series Carrier has eight keys. The additional key on the carrier is the Select key, used to connect the SDCP to a specific slot in the carrier.
The key returns you to the Top-Level menu display from anywhere in the menu tree.
Pressing while changing configuration options displays the message Save Straps? Yes No. If No is selected, changes made to configuration options are not saved and the Top-Level menu appears. If Yes is selected, then changes are saved to either Active (Saved), Customer 1, or Customer 2 configuration areas.
The key moves you up one level in the menu tree.
Use the and keys to move the viewing window left or right and to scroll the remaining branches and selections into view. A maximum of three selections can be displayed at one time.
These keys also allow you to move the cursor one character to the left or right on data entry displays; for example, to allow entry of one digit at a time.
Other Indicators · Remote Mode Indicator

F1 F2 F3 Keys
Function keys F1, F2, and F3 select the LCD choice that appears above the function key. Refer to the Summary section in Chapter 4 for the exception.
If the displayed LCD choice spans more than one function key, then any of the function keys select that choice.
In the screen examples, the F1 key is highlighted where multiple function keys select the choice.
The Select key appears on the optional SDCP of the COMSPHERE 3000 Series Carrier. It is used to connect the SDCP to a modem in a specific slot in the carrier.
The menu tree is a hierarchical structure used to display functions that configure and control local and remote 392xPlus modems. It is accessed via the DCP and is shown in Appendix A.
“Status” Displays the current status of the modem along with the data rate and the error control mode.

The menu tree contains the following branches:
Status — Used to monitor the current status of the VF line and DTE interface as well as view the identity of the modem.
Configure — Used to change and save the modem’s configuration options.
PList — (Poll List) Used to identify downstream modems in order to support multipoint health and status polling and multipoint link download broadcasting.
Control — Used to control the modem’s hardware and software functions.
Test — Used to begin and end various modem tests.
SubHS — (Sub-Network Health and Status) Used to display alarm conditions in downstream modems.
Call Setup — Used to dial, disconnect, and answer telephone calls as well as store up to 24 telephone numbers in directory locations.
Talk/Data — Used to switch the modem between Talk mode (the modem is disconnected from the VF line) and Data mode (the modem is connected to the VF line) when dialing via either the DCP or a telephone.
Security — Used to control the modem’s dial access security. (The Security branch only appears in Singleport mode.)
Remote — Used to access and control a remote 392xPlus modem.
All menu tree branches are discussed later in Chapter 3 except for Configure, which is discussed in Chapter 4, and Security, which is discussed in Chapter 6. Functions that appear on the LCD vary depending upon the type of model installed, its operating mode, and software configuration.

Access to all menu tree branches from the DCP begins at the Top-Level menu, the head of the menu hierarchy. The LCD’s top line identifies the modem status, as listed in Table 3-3, while the bottom line displays the main menu tree branches as well as operational and security messages, as listed in Table 3-4 and Table 3-5.
Status Message Indicates
Normal Operation Leased:MR* The modem is operating on leased lines and receiving at the displayed data rate.
Idle:MR* The modem is configured for dial network operation and is on-hook.
OnLine:MR* EC** The modem is online, in Data mode, and operating at the displayed data rate. EC (error control) appears if error control is operational.
Ring Indicate The local modem is receiving an incoming ring.
Test:MR* The modem is in test mode operating at the displayed data rate.
Alarm*** Make Busy The modem is in a Make Busy condition.
Power On Fail The modem has failed its Power-On Self-test.
SelfHealth Fail A failure has occurred in the modem’s hardware components.
Call Setup Off Hook The modem is off-hook and waiting to dial a telephone number.
Dialing The originating modem is dialing a telephone number.
Remote Ring The remote modem is ringing.
Training**** The modem is training or retraining.
EC Negotiating The local and remote modems are negotiating the highest possible level of error control compatible between both modems. Once a level is selected, this LCD message disappears.
Dial Backup or L d B k
Stndby:MR* The modem is operating in Dial Standby mode. p Leased Backup DialBckUp:MR* The modem is operating in a Dial Backup mode at the displayed data rate and is configured for Direct mode.
Backup:MR* EC**
The modem is operating in Dial Backup mode and is configured for error control and data compression on leased lines.
Stndby:MR* EC** The modem is operating in Dial Standby mode and is configured for error control and data compression on leased lines.
* MR. Modem Rate indicates the data rate the modem is using. One of the following values appears: 300, 1200, 2400, 4800, 7200, 9600, 12.0 (12,000), 14.4 (14,400), 16.8 (16,800), 19.2 (19,200) 21.6 (21,600), 24.0 (24,000), 26.4 (26,400), 28.8 (28,800), 31.2 (31,200), or 33.6 (33,600) bps.
** EC. Error Control indicates the modem is online and using V.42 or MNP error control. One of the following values appears after the modem rates listed above: MNP2, MNP3, MNP4, MNP5, V42, V42b, or NoEC. (NoEC indicates the modem is connected in Buffer mode rather than error control. If an EC value does not appear, then the modem is in Direct mode.)
*** The Alarm Status Messages only appear when the Normal Operation Status Messages appear; the LCD alternates between the two message sets.
**** The Training message may also appear in normal Trellis Multipoint (TMp) operation.
DCP Operation

Status Indicates Message
Call Failure Busy Signal The answering modem is busy.
As a result of failed call attempts, this number can not be called at this time. Please try again later.
Dial Line in Use The modem is operating on dial networks when another call attempt is issued.
As a result of failed call attempts, this number can not be called again.
Invalid Number The modem has dialed a telephone number not stored in a directory location.
Line Occupied The line is being used by the associated telephone.
No Answer Tone The answering modem did not answer within the time limit specified by the No Answer Timeout configuration option. The network tones (if any) could not be interpreted by the modem.
No Dial-DTR The modem cannot dial because DTR is OFF.
No Dial-Test The modem cannot dial because it is running a Test.
No Dial Tone The modem has aborted the call because it cannot detect a dial tone.
No Quiet Answer The modem has detected No Quiet Answer (@) before the time-out setting of the No Answer Disconnect configuration option.
The answering modem did not answer within the time limit specified by the No Answer Timeout configuration option. A ringback signal was detected.
Trunk Busy The modem is receiving a fast (trunk) busy.
Wrong Call The call was answered, but not by a modem. No answer tone.
The Delayed Number and Forbidden Number messages appear only in countries where the number of repeat call
attempts are restricted. The regulations vary in each country. If the number is delayed, the value of the delay (in minutes) can be displayed by entering Directory Status (see Call Setup Branch).
The Line Occupied message appears only in countries where the Offhook Detector is enabled. The purpose of the
Offhook Detector is to detect whether the telephone associated with the modem is off-hook. It is enabled on a per
country basis, and this setting can not be changed by a command. The Offhook Detector is enabled in Austria, Germany, and Switzerland.
Delayed Number · Forbidden Number · Ringback Timeout

Status Indicates Message
Call Disconnect ATH Disconnect The modem has disconnected due to an ATH command.
Bad Lines Disc The modem has disconnected because the lines do not support the modulation and/or data rate selected.
No Carrier Disc The modem disconnects due to the loss of carrier signal from the remote modem.
DTR Disconnect The modem has disconnected due to the loss of DTR from the DTE.
EC Disconnect The modem has disconnected due to failure to negotiate Error Control mode.
Inv Rate Disc When using V.32bis modulation, the remote modem does not support the data rate used by the local modem.
LnCurrnt Disc The modem has disconnected due to the loss of line current.
LongSpace Disc The modem has disconnected due to the detection of a long space.
NoData Disc The modem has disconnected due to a lack of transmitted and received data.
Disconnecting The modem has begun the disconnect sequence.
RmtCmnded Disc The modem has disconnected due to a V.32 Cleardown received from the remote modem.
Talk Mode The modem is in Talk mode.
A local download of firmware or a remote cloning of firmware has failed. The modem is currently in a Download Only mode in which only another download attempt is possible.
A local download of firmware or a remote cloning of firmware was successful.
RemClone Failed A remote cloning of firmware has failed. This message appears on the local modem’s LCD.
A remote cloning of firmware was successful. This message appears on the local modem’s LCD.
A broadcast cloning of firmware is complete. Look under the Control branch for multipoint cloning results. This message appears on the local modem’s LCD.
Reset by AT command
The modem has performed a reset in response to an ATZ command.

Messages listed in Table 3-4 are common operational messages that occur during modem operation. These messages normally appear on the second line of the LCD.
Common Operational Message Indicates
Please Wait... A command to a local device takes more than two seconds to complete.
Command Sent... A command is sent to a remote modem.
No Rem Response or Remote Modem Fail
A remote modem does not respond to a command within 5 seconds.
Command Complete A command, issued to a local or remote modem, is completed.
Invalid Command The modem cannot complete a command.
Messages listed in Table 3-5 are dial access security messages.
Dial Access Security Message Indicates
Get VF PsWd The answering modem is waiting for the originating caller to transmit a VF password.
Get DTE PsWd The answering modem is waiting to receive a valid DTE password from the remote DTE.
VF PsWd Timeout The modem did not finish answering a call (disconnected) because the allowed time limit was exceeded before the modem received a VF password from the originating dialer.
Unknown DTEpswd The modem did not finish answering a call (disconnected) because the DTE passwords received from the remote DTE were invalid.
No Orig PsWd The modem did not attempt to establish a call as requested because the AT dial command did not contain an originate access password.
Unknown VF PsWd The modem did not finish answering a call (disconnected) because the modem received an invalid VF password.
DTEpswd Timeout The modem did not finish answering a call (disconnected) because the allowed time limit was exceeded before the modem received a DTE password from the remote DTE.
Inval Orig PsWd The modem did not attempt to establish the call as requested because the originate password in the AT dial command was not valid.
DTR Dial Blocked DTR dialing is not permitted when security is enabled. This message appears if DTR dialing is used and Answer Access or Originate Access security is enabled.
SecurityBlocked The access verification capabilities are not available and the modem does not pass data to the DTE under any circumstances. This message appears only when the modem is in base mode (a mode that occurs during a firmware download) and Answer Access Security is enabled.

The Top-Level menu’s main branches appear on the LCD in the order of Status, Configure, Control, Test, Call Setup, Talk/Data, Security, and Remote. These branches are discussed in this chapter except for the Configure branch which is reserved for Chapter 4, DCP Configuration, and the Security branch which is reserved for Chapter 6, Dial Access Security.
The Quick Configuration display indicates the basic operational characteristics of the modem.
Leased:28.8 Status Configure
F2 F3
The modem’s Quick Configuration information appears on the LCD’s bottom line.
To access the Quick Configuration display from the Top-Level display, press the key. Based on the configuration of the modem, one of two screens appear.
If the modem is not operating with V.34 modulation, the following screen appears.
Leased:19.2 > abbb cdd ee f
F2 F3
If the modem is operating with V.34 modulation, the following screen appears.
xxxx yyyyy zz > abbb cdd ee f
F2 F3
The V.34 modulation Quick Configuration information appears on the LCD’s top line.
In Dial mode, where Automode automatically adapts to the modulation scheme of the remote modem, the V.34 Quick Configuration display may not necessarily indicate the actual (V.34) online modulation.
For more information on V.34, refer to the V.34 section in this chapter.
DCP Operation

The following provides information about the Quick Configuration LCD display.
a Displays the network position of the modem. The letter C indicates this is a control modem, and T indicates this is a tributary modem.
bbb Displays the network management address of the modem. The valid address field range is from 001 to 256.
c Displays the DTE mode. The letter A indicates the currently selected port is in Asynchronous mode, and S indicates the currently selected port is in Synchronous mode. If the NMS channel is selected, the letter in this location (A or S) will indicate the status of Port 1. (The NMS channel is always in Asynchronous mode.)
dd Displays the line mode. The letters LA indicate Leased Answer mode, LO indicate Leased Originate mode, and D indicates Dial mode.
ee Displays the modem DTE port that currently appears by the EIA status indicators on the DCP.
CC indicates Control Channel. DC indicates Diagnostic Channel. P1 indicates Port 1 in Singleport mode.
The following only appear on the 392x multiport modem:
M1 indicates Port 1 when TDM/MSD is enabled. M2 indicates Port 2 when TDM/MSD is enabled. M3 indicates Port 3 when TDM/MSD is enabled. M4 indicates Port 4 when TDM/MSD is enabled. B1 indicates Port 1 when DTE Bridge is enabled. B2 indicates Port 2 when DTE Bridge is enabled.
ffff Displays the modem’s modulation scheme as shown below:
V34 indicates V.34 family modulation. V32t indicates V.32 terbo modulation. V32b indicates V.32bis modulation. V32 indicates V.32 modulation. TMp indicates Trellis Multipoint modulation. V22b indicates V.22bis modulation. V27b indicates V.27bis modulation. V33 indicates V.33 modulation. V29 indicates V.29 modulation. V22 indicates V.22 modulation. V23 indicates V.23 modulation. V21 indicates V.21 modulation. 212A indicates Bell 212A modulation. 103J indicates Bell 103J modulation.
xxxx Modem Transmit Rate indicates the rate at which the modem is transmitting data. Possible values are 2400, 4800, 7200, 9600, 12.0 (12,000), 14.4 (14,400), 16.8 (16,800), 19.2 (19,200), 21.6 (21,600), 24.0 (24,000), 26.4 (26,400), 28.8 (28,800), 31.2 (31,200), or 33.6 (33,600) bps.
yyyyy Symbol Rate indicates the baud rate used by V.34 modulation. Refer to CCITT specifications. Possible values are 3429, 3200L, 3200H, 3000L, 3000H, 2800L, 2800H, 2743L, 2743H, 2400L, 2400H.
zz Transmit Level indicates the power level at which the modem is transmitting when running V.34 modulation. Possible values are 01–64 dBm.
To exit the Quick Configuration function and return to the Top-Level menu, press the , , or key.

The Status branch of the Top-Level menu allows you to view the current status of the leased-line or dial connection, the identity (for example, serial number and model number) of your equipment, and the DTE interface.
Configure PList Control Test SubHS Call_Setup Tlk/Data Security Remote
DeviceHS VF Identity DTE Options Record
Service_Log V.34 Backup
Major Minor Status Dial Thresh Security Port1 Port2 Port3 Port4
Display Clear Ser# Mod# FRev HPt# FPt# Country
LSD DTR DSR Tst TXD RXD RTS CTS
TxRate RxRate SymbolRate Tx Level AsymRate
Line = Pri 4W APL Line = Pri 2W APL Line = Bkup 2W APL Line = Dial Backup Line = Dial ONLY Line = No Sync
SigQual RcvLevel Sig/Noise NrEchLvl FarEchLv FarEchDel EchoFreqOff Phase Hts Impul Hts DropOuts Retrains Phas Jtr NonLinear FreqOffset Gain Hts
To access Status from the Top-Level menu, select Status.
Leased:28.8 Status Configure
F2 F3

DeviceHS provides a ‘‘snapshot” of current modem alarms which are active at the time the DeviceHS function is selected.
To access DeviceHS from the Status branch, make the following selection:
F1
Select DeviceHS.
F2 F3
If alarms are present, press the appropriate function key to view the messages associated with these alarms (Table 3-6). If needed, press the key to scroll to additional alarm types. If no alarms are present, the word Normal appears on the LCD.
Type Message Indicates
Major Device Failure A device/self test has failed. The probable cause is a modem hardware problem or diagnostic memory failure.
Facility Fault A severe data transport problem is occurring due to poor line conditions. No signal or a very poor signal is being received.
Streaming DTE The modem is in an antistreaming condition. The RTS input to the modem was held ON for a period exceeding the time selected by the RTS Antistream configuration option. (Refer to the DTE Interface section in Chapter 4 for a description of the RTS Antistream configuration option.)
Access Security A dial access security alarm is active. (Refer to the Security section of this table for dial access security conditions.)
Minor VF Threshold One or more of the analog parameter thresholds have been exceeded. The probable cause is poor line conditions or improper threshold settings. Thresholds may be set through the DCP or NMS commands.
DTE Alarm One or more of the DTE signals on one or more of the DTE ports are in alarm mode. (Refer to the Port 1, 2, 3, 4 section of this table for DTE alarm conditions.)
Rate Fallback Due to poor line conditions, the modem’s transmit rate is below the configured rate. (Refer to the Leased Line and Dial Line sections in Chapter 4 for a description of configuration options affecting rate.)

Type Indicates Message
Status Subtree Truncate Downstream health and status information has been truncated because it overflowed system limits. There is a large amount of health and status information in the subnetwork.
Test Mode The modem or an upstream device is running a disruptive test.
Disabled The modem’s DTE port has been disabled.
On Dial Backup The modem is operating in Dial Backup mode.
FW Downloading A firmware download is in progress.
Primary Line Good The modem is currently operating on the 2-wire backup facility, the Lease Lookback option is enabled, and the modem detects continuity on the primary 4-wire leased lines.
Backup Line Bad The modem is currently operating on the primary 4-wire leased facility with 2-wire leased lines selected as the backup facility, the BackupLineCheck configuration option is enabled, and the modem detects continuity on the 2-wire backup leased lines.
Data Blocked The modem’s data path is blocked.
On Lease Backup The modem is operating in 2-wire Leased Backup mode.
PSTN Test Fail The modem failed either the Dial Tone Detection or the Ring Tone Detection portion of the Call Test command.
Dial Make Busy Mode The modem is in a Make Busy condition Dial Make Busy Mode The modem is in a Make Busy condition.
Service Line (Model 3921Plus only) The modem installed in a COMSPHERE 3000 Series Carrier has been switched to a service line.
Short Hold Time The modem’s dial hold time has been shortened.
Non-Answering The modem is in a non-answering mode.
Thresh* RSL High Threshd The received signal level (RSL) has exceeded the upper threshold.
RSL Low Threshld The RSL is less than the lower threshold.
SNR Threshold The signal-to-noise ratio has exceeded the threshold.
Non-linear Dist The non-linear distortion exceeded the threshold.
Retrains The number of retrains exceeded the threshold.
Signal Quality The signal quality is less than the threshold.
Far Echo Threshd The far end echo level exceeded the threshold.
Near Echo Thresh The near end echo level exceeded the threshold.
Phase Jitter The phase jitter level exceeded the threshold.
Phase Hit Thresh The number of phase hits has exceeded the threshold.
Impulses Hit The number of impulse hits exceeded the threshold.
Gain Hit Threshld The number of gain hits exceeded the threshold.
Drop Outs Thresh The number of drop outs exceeded the threshold.
Frequency Offset The frequency offset level exceeded the threshold.
* Not supported in every modulation.
DCP Operation

Type Indicates Message
Security Database Reset The security database has been reset (passwords erased).
Password Protect Security password protection is enabled.
Mode Change There has been a change in security mode. (Refer to Chapter 6, Dial Access Security.)
Password Change A security password has been changed.
Database Change The security database containing passwords has been changed.
Ports 1 Ports 2
Rx Data Alarm The alarming DTE port’s RXD signal is in an alarm condition. Ports 2 Ports 3 Tx Data Alarm The alarming DTE port’s TXD signal is in an alarm condition. Ports 3 Ports 4 DTR Alarm The alarming DTE port’s DTR signal is in an alarm condition.
CTS Alarm The alarming DTE port’s CTS signal is in an alarm condition.
RTS Alarm The alarming DTE port’s RTS signal is in an alarm condition.
DSR Alarm The alarming DTE port’s DSR signal is in an alarm condition.
LSD Alarm The alarming DTE port’s LSD signal is in an alarm condition.
Auto Stream Dis The port is disabled due to an antistreaming condition. (Refer to the Streaming DTE message in the Major Alarm section of this table.)
Disabled The modem’s alarming DTE port has been disabled.
To exit DeviceHS and remain in the Status Branch, press the key. To exit and return to the Top-Level menu, press the key.
VF enables you to display the condition of the leased or dial connection. VF also allows you to clear the VF counters.
To access VF from the Status branch, make the following selection:
F2 F3
Select VF. The selections Display or Clear appear on the LCD’s bottom line.

Status:VF Display Clear
F2 F3
To display VF conditions, select Display from the Status:VF screen.
Status:VF > SigQual=Excelent
F2 F3
If the modem is receiving a signal, the signal quality appears on the LCD’s bottom line. If the modem is not receiving a signal, the message No Signal appears.
Press the key to scroll and view the VF conditions.
Not all conditions are available at 4800 bps.
SigQual Signal Quality displays the condition of the VF line. Possible values are Excelent (Excellent), Good, Fair, Poor, or No Signal. These parameters appear for V.34, V.32 terbo, V.32bis, and V.32 modulations.
RcvLevel Receive Signal Level displays, in decibels referenced to one milliwatt (dBm), the actual strength of the incoming signal. This parameter appears for V.34, V.32 terbo, V.32bis, V.32, and Trellis Multipoint modulations.
Sig/Noise Signal-to-Noise Ratio displays, in decibels, the receive signal strength relative to noise on the line. This parameter appears for V.34, V.32 terbo, V.32bis, V.32, and Trellis Multipoint modulations.
NrEchLvl Near End Echo Level displays the signal level, in decibels referenced to one milliwatt (dBm), of that portion of the transmit signal which has been echoed back by the local line termination. This parameter appears for V.34, V.32 terbo, V.32bis, and V.32 modulations (in 2-wire only).
FarEchLvl Far End Echo Level displays the signal level, in decibels referenced to one milliwatt (dBm), of that portion of the transmit signal which has been echoed back by the remote line termination. This parameter appears for V.34, V.32 terbo, V.32bis, and V.32 modulations (in 2-wire only).
FarEchDel Far End Echo Delay displays the roundtrip delay in milliseconds of the far end echo. This parameter appears for V.34, V.32 terbo, V.32bis, and V.32 modulations (in 2-wire only).
DCP Operation · Displaying VF Conditions

EchoFreqOff Echo Frequency Offset displays the frequency offset of the far end echo. This parameter appears for V.34, V.32 terbo, V.32bis, and V.32 modulations (in 2-wire only).
Phase Hts Phase Hits reports the total hit count of sudden uncontrolled changes in the phase of the receive signal for the past 15 minutes. This parameter appears for V.32 terbo, V.32bis, and V.32 modulations (in 4-wire only).
Impul Hts Impulse Hits reports the total hit count of large burst or spikes that are larger than normal peaks of random white noise for the past 15 minutes. This parameter appears for V.32 terbo, V.32bis, and V.32 modulations (in 4-wire only).
DropOuts Drop Outs reports the total number of large reductions in channel gain for the past 15 minutes. This parameter appears for V.32 terbo, V.32bis, and V.32 modulations (in 4-wire only).
Retrains Retrains displays the number of retrains over the last 15 minutes of operation. The total 15-minute accumulation is updated every minute. This parameter appears for V.32 terbo, V.32bis, V.32, and Trellis Multipoint modulations (in 4-wire only).
Phas Jtr Phase Jitter is the non-constant variation in the phase of the receive signal carrier. The jitter is typically introduced by analog power supplies and is predominantly sign waves with a frequency of 50 Hz or 60 Hz. This parameter appears for V.32 terbo, V.32bis, and V.32 modulations (in 4-wire only).
NonLinear Non-Linear Distortion displays distortion which is usually associated with pulse-code modulation (PCM) compandor noise on the phone line. This parameter appears for V.32 terbo, V.32bis, V.32, and Trellis Multipoint modulations (in 4-wire only).
FreqOffset Frequency Offset reports the variation in all frequencies in the voice band. This parameter appears for V.32 terbo, V.32bis, and V.32 modulations (in 4-wire only).
Gain Hts Gain Hit reports the total number of rapid changes in the receiver power level for the past 15 minutes. This parameter appears for V.32 terbo, V.32bis, and V.32 modulations (in 4-wire only).
The Clear command resets the retrain, impulse hits, gain hits, phase hits, and drop outs.
Status:VF Display Clear
F2 F3
To clear the VF counters, select Clear.
Clearing VF Counters

VF Counter Clear Command Complete
F2 F3
The message Command Complete appears on the LCD’s bottom line indicating the VF Counters are cleared.
To exit VF and remain in the Status Branch, press the key. To exit and return to the Top-Level menu, press the key.
Identity displays the modem’s serial number, model number, firmware revision level, hardware revision number and firmware part number. Retrieval of this information is useful if you are purchasing additional or replacement modems and/or making firmware upgrades.
To access Identity from the Status branch, make the following selection:
F2 F3
Press the key until Identity appears. Select Identity.
Status:Identity > Ser#=00000000
F2 F3
The modem’s serial number appears on the LCD’s bottom line. Press the key to scroll and view the model number, firmware revision level, hardware part number, and firmware part number.
Ser # Serial number is an 8-digit number that identifies the modem.
Mod # Model number is an alphanumeric number that identifies the modem as either a Model 3920Plus or Model 3921Plus modem.
FRev Firmware revision level is an alphanumeric number that identifies the level of firmware loaded in the modem.
HPt # Hardware part number is an 11-digit number that identifies the circuit card in the modem.
FPt # Firmware part number is an 11-digit number that identifies to service personnel the firmware release number.
Country Country code is a 7-text character that identifies the current country code.
To exit the Identity function and remain in the Status branch, press the key. To exit and return to the Top-Level menu, press the key.
DCP Operation

DTE displays the state and/or activity of the following interface leads: LSD, DTR, DSR, TST, TXD, RXD, RTS, and CTS. The interface leads status is updated every 5 seconds.
To access DTE from the Status branch, make the following selections:
F1
Press the key until DTE appears. Select DTE.
Select DTE Port > Port1 Port2
F2 F3
Select the appropriate port by pressing the corresponding function key. Press the key to scroll other ports into view. Only Ports 1 and 2 appear when the the DTE Bridge configuration option is enabled.
This screen does not appear in Singleport mode.
LSD DTR DSR Tst> _ * _
F2 F3
The activity and state of the modem’s DTE signal appear on the LCD’s bottom line. Press the key to scroll other signals into view.
The LCD’s bottom line displays a pair of symbols for each interface lead. The first symbol indicates the signal’s activity since entering the DTE status display. An * (asterisk) indicates at least one transition while a blank space indicates no transitions.
The second symbol indicates the state of the interface lead at the sampling time. A (solid block) indicates a Space or ON condition while an underscore ( _ ) indicates a Mark or OFF condition.
To exit this function and remain in the Status branch, press the key. To exit and return to the Top-Level menu, press the key.

When running V.34 modulation, this function displays information about the modem’s receiving and transmitting data rate, symbol rate, transmitting level, and asymmetric rate.
The V.34 status display is available only when the modem is configured for V.34 modulation.
To access V.34 from the Status branch, make the following selection:
F2 F3
Select V.34.
F2 F3
If the modem is receiving a signal, the signal quality appears on the second LCD line. Press the
key to scroll and view the V.34 modem receive rate, symbol rate, transmit rate, and asymmetric. If the modem is not receiving a signal, the message No Sync appears.
TxRate Modem Transmit Rate indicates the rate at which the modem is transmitting data. Possible values are 2400, 4800, 7200, 9600, 12.0 (12,000), 14.4 (14,400), 16.8 (16,800), 19.2 (19,200), 21.6 (21,600), 24.0 (24,000), 26.4 (26,400), 28.8 (28,800), 31.2 (31,200), or 33.6 (33,600) bps.
RxRate Modem Receive Rate indicates the rate at which the modem is receiving data. Possible values are 2400, 4800, 7200, 9600, 12.0 (12,000), 14.4 (14,400), 16.8 (16,800), 19.2 (19,200), 21.6 (21,600), 24.0 (24,000), 26.4 (26,400), 28.8 (28,800), 31.2 (31,200), or 33.6 (33,600) bps.
SymbolRate Symbol Rate indicates the baud rate used by V.34 modulation. Refer to CCITT specifications. Possible values are 3429, 3200L, 3200H, 3000L, 3000H, 2800L, 2800H, 2743L, 2743H, 2400L, 2400H.
TxLevel Transmit Level indicates the power level at which the modem is transmitting when running V.34 modulation. Possible values are 01–64 dBm.
AsymRate Asymmetric Rate indicates the rate symmetry when running V.34 modulation. Refer to the Asymmetric Rate configuration option in the Dial Line or Leased Line section of Chapter 4.
DCP Operation

The Status Backup function displays the configuration of the modem’s current operating line facility and the configuration and condition of the inactive line.
The modem’s rear panel has two line interface jacks: LEASE and DIAL (see Figure 2-1 in Chapter 2). The jack labeled LEASE is the APL primary interface and accepts either 2-wire or 4-wire APL. The jack labeled DIAL is the backup interface and accepts either 2-wire APL (Dual Lease Line) or Dial lines.
To access Backup from the Status branch, make the following selection:
Press the key until Backup appears.
F2 F3
Select Backup.
Status:Backup > Line=Pri 4w APL
F2 F3
The configuration of the current operating line facility (either APL primary or backup) appears (Refer to Table 3-7).
Press the key to display the next screen.
Status:Backup < Bkup:2wAPL=Good
F2 F3
This screen displays the configuration and condition of the inactive line facility (either APL primary or backup).
There are four condition codes, Good, Bad, , and ‘ ’ (blank).

Table 3-7 provides information about the Status Backup screens. The first column lists all possible configurations for the modem’s currently active line. The second column lists all possible configurations for the modem’s inactive lines. The third column provides information about the inactive line condition.
XXXX represents the condition code of the inactive line.
Active Line 1st Screen Display Inactive Line 2nd Screen Display Possible Inactive/Backup Line Condition
Line=Pri 4w APL or Line=Pri 2w APL
Bckup:2wAPL=XXXX or Bckup : Dial =(blank)
Good indicates that line continuity is detected.
Bad indicates that line continuity is not detected.
indicates that the line condition is unknown (Backup Facility Check is making its first determination of the line conditions since the last retrain).
blank indicates that the BackupLineCheck configuration option is disabled or not available. Refer to the BackupLine Check configuration option in the Leased Line section of Chapter 4.
Line=Bkup 2w APL or Line = Dial Backup
Pri 4w APL =XXXX or Pri 2w APL =XXXX
Good indicates the line condition is good.
Bad indicates the line condition is bad.
indicates the line condition is unknown (Lease Lookback has not had enough time to make an initial appraisal of the line conditions since the last retrain).
blank indicates the Lease Lookback option is disabled. Refer to the BackupLine Check configuration option in the Leased Line section of Chapter 4.
Line=Dial Only No second screen display.
is no backup.
factory default options are loaded from the Async Dial, Sync Dial, or UNIX Dial templates.
Line=No Sync No second screen display.
either the primary or backup line facility.
To exit this function and remain in the Status branch, press the key. To exit and return to the Top-Level menu, press the key.
DCP Operation

The Options Status function displays all optional firmware features currently installed in the modem. If no firmware options are installed, None_Installed appears on the LCD.
To access Options from the Status branch, make the following sections:
F1
Press the key until Options appears. Select Options.
Options:Status > V.29 V.33
F2 F3
If optional features are installed in the modem, they appear on the LCD’s bottom line. If other features are installed, press the key to scroll other features into view.
To exit this function and remain in the Status branch, press the key. To exit and return to the Top-Level menu, press the key.
Record is a troubleshooting tool used in conjunction with support personnel. This function retrieves and reports any sequence faults to support personnel. A sequence fault is an irregular or unexpected event.
There are two selections under Record: Display and Clear. Display allows up to eight sequence fault messages that are recorded by the modem and displayed on the LCD in descending order. If no sequence faults have occurred, then Modem O.K. appears.
Clear is used to remove all sequence fault messages from nonvolatile memory and the LCD.
To access Record from the Status branch, make the following selections:
F2 F3
Press the key until Record appears. Select Record.

Record Status Display Clear
F2 F3
To display sequence faults, select Display.
Record Number 1 Modem O.K.
F2 F3
The LCD displays the first sequence fault field. (Sequence fault fields range from 1 to 8 and are identified by a number in the upper right corner.) Press the key to view the remaining fields. The message Modem O.K. appears if no sequence faults have occurred.
To remove sequence fault records from both the LCD and nonvolatile memory, select Clear. The message Modem O.K. appears.
To exit this function and remain in the Status branch, press the key. To exit and return to the Top-Level menu, press the key.
Service Log is a troubleshooting tool used in conjunction with support personnel. Use this function to retrieve and report Service Log data to support personnel.
To access Service Log from the Status branch, make the following selections:
F2 F3
Press the key until Service appears. Select Service Log.
F2 F3
Support personnel will request the applicable information from this screen.
xx displays the Service Log number.
mm/dd/yy displays the date (month/day/year).
zz displays the Customer Support code number.
DCP Operation

Select Nxt to scroll through the entries in the Service Log.
To exit this function and remain in the Status branch, press the key. To exit and return to the Top-Level menu, press the key.
The Configure branch of the LCD allows you to change and save the modem’s configuration options. For configuration options and DCP configuration procedures, refer to Chapter 4, DCP Configuration.
The Poll List (Plist) branch of the Top-Level menu allows you to identify downstream modems in order to support health and status polling and download broadcasting. The maximum number of devices is 32 on the secondary channel and 64 on the diagnostic channel.
Status Configure Control Test SubHS Call_Setup Tlk/Data Security Remote
Display Clear Change Add Acquire
To access PList from the Top-Level menu, make the following selections:
* Point-to-point control modems only poll address 01, and point-to-point tributary modems are always set to address 01.

Leased:28.8 PList Control
F2 F3
Press the key until PList appears. Select PList.
Within a network link, a control modem can communicate with a tributary modem by using the tributary modem’s network management address for polling functions. Each TMp tributary modem must have a different network management address. Refer to the Misc section in Chapter 4 for a description of the network management address (NetMngmtAddress) configuration option.
Over a diagnostic channel a tributary modem can communicate with control modems by using the control modem’s network management address for polling.
In the poll list, modems are listed as either Active or Skip. Downstream modems in the Active poll list are polled by the modem. Modems in the Skip poll list are passed over during the polling process, but not deleted from the poll list.
Display allows you to view the modem’s poll list.
To access Display from the PList branch, make the following selection:
F2 F3
Select Display.
If there are no modems in the poll list when you select Display, the message Poll List Empty! appears on the second line of the LCD.
Poll List:Disp Nxt xxx yyyyyy
F2 F3
If there are modems in the poll list when you select Display,
xxx Displays the network management address of the modem in the poll list.
yyyyyy Displays either Active or Skip to indicate the poll list in which the network management address is included.
DCP Operation

Select Nxt to scroll through the entries in the Active or Skip poll lists.
To exit this function and remain in the PList Display branch, press the key. To exit and return to the Top-Level menu, press the key.
The Clear function does not appear in Remote mode.
Clear deletes the modem’s poll list.
To access Clear from the PList branch, make the following selection:
F2 F3
Select Clear.
The message Command Complete appears on the second line of the LCD to indicate that the poll list has been cleared.
To exit this function and remain in the PList branch, press the key. To exit and return to the Top-Level menu, press the key.
The Change function does not appear in Remote mode.
Change allows you to change the modem’s poll list.
To access Change from the PList branch, make the following selections:
F2 F3
Press the key until Change appears. Select Change.
Change allows you to add modems to the Active poll list (Active), delete modems from both Active and Skip poll lists (Delete), and move modems from the Active to the Skip poll list.
Poll List:Chang > Active Delete
F2 F3

To implement Change, select the appropriate function (Active, Delete, or Skip). (For Skip, you will need to press the key until Skip appears.)
Poll List:yyyyyy Ent xxx
F2 F3
The function field (yyyyyy) displays the function selected (Active, Delete, or Skip).
The address field (xxx) displays the network management address of the modem to be changed. The valid address field range is from 001 to 256.
To increment digits within the address field (xxx), use the and keys to position the cursor ( _ ) under the digit to be incremented. Press the F2 () key to increment the digit.
Press Enter (Ent) to implement the function (yyyyyy) you selected (Active, Delete, or Skip). The message Command Complete appears on the second line of the LCD to indicate that the poll list change occurred. If the message Poll List Check appears, you attempted to delete an address that is not on the poll list, or you attempted to add an address that is already on the poll list. If the message Poll Lst too Big appears, you exceeded the maximum number of downstream devices. To return to the selected function (Active, Delete, or Skip), press the key. The address automatically increments upon returning to this function.
To exit this function (Active, Delete, or Skip) and remain in the PList Change branch, press the key. To exit and return to the Top-Level menu, press the key.
The Add function does not appear in Remote mode or on control modems.
Add allows you to add the tributary modem to a control modem’s poll list. This function should be initiated from only one tributary modem at a time.
To access Add from the Plist branch, make the following selections:
F2 F3
Press the key until Add appears. Select Add.
Poll List:Add Command Complete
F2 F3
DCP Operation

The message Command Complete appears on the LCD to indicate that the tributary modem will be added to the control modem’s poll list.
To exit this function and remain in the PList branch, press the key. To exit and return to the Top-Level menu, press the key.
The Acquire function does not appear in Remote mode.
Acquire allows you to acquire an active poll list consisting of all modems that are one tier downstream. A modem adds to its poll list all downstream modems that respond to a poll.
To access Acquire from the Plist branch, make the following selections:
F2 F3
Press the key until Acquire appears. Select Acquire.
If an error message (OtherTestActive or Unable To Acquir) appears on the second line of the LCD, move up one level in the menu tree to clear the message and return to the PList Acquire branch. The OtherTestActive message indicates that a test is running which blocks the Acquire function. The Unable To Acquir message indicates that the diagnostic network is in a busy state.
Poll List:Acquir Abort xxx yyy
F2 F3
The address field (xxx) is incremented sequentially from 001 to 256 as polls are transmitted from the modem to the downstream modem(s). To be added to the modem’s poll list, the device must respond to a poll after receiving its address. The Acquire function can be canceled by selecting Abort.
The number field (yyy) indicates the total number of devices that responded to the modem’s polls thus far. These devices have been acquired for the poll list.
Select Abort or allow the function to complete.

Poll List:Acquir Num Acquired yyy
F2 F3
The number field (yyy) indicates the total number of devices acquired for the poll list.
To exit this function and remain in the PList branch, press the key. To exit and return to the Top-Level menu, press the key.
The Control branch of the Top-Level menu allows you to manage hardware and software functions, such as speaker volume, reset, busy out, and firmware download.
Status Configure PList Test SubHS Call_Setup Tlk/Data Security Remote
Speaker Reset Data_Stream Make_Busy
To access Control from the Top-Level menu, make the following selections:
Leased:28.8 Control Test
F2 F3
Press the key until Control appears. Select Control.

Speaker allows you to make temporary adjustments to the modem’s speaker volume. Upon a reset, speaker volume returns to its configured setting. For more information on speaker settings, refer to the Misc section in Chapter 4.
To access Speaker from the Control branch, make the following selection:
F2 F3
Select Speaker.
Speaker Control > Off Low Med
F2 F3
Press the key and appropriate function keys to choose the desired selection.
Off Turns the speaker off.
Low Adjusts the speaker to low volume.
Med Adjusts the speaker to medium volume.
High Adjusts the speaker to high volume.
The message Command Complete appears on the LCD.
To exit Speaker and remain in the Control branch, press the key. To exit and return to the Top-Level menu, press the key.
DCP selections are

Reset causes the modem to stop operation and perform a complete program restart. The modem begins the power-up test sequence that ends with the Top-Level menu displayed on the LCD. Configuration options stored in an Active (Saved) configuration area are copied to the Active (Operating) configuration area.
To access Reset from the Control branch, make the following selection:
F2 F3
Select Reset.
The message Reset appears momentarily before the modem performs the power-up diagnostic test sequence.
Use Data Stream to enable or disable the modem’s data transmitter function on a specific port or on all ports.
The Data Stream function is not available in Async mode in Singleport mode.
To access Data Stream from the Control branch, make the following selections:
F2 F3
Press the key until Data Stream appears. Select Data Stream (F1).
Select DS Port > Port1 Port2
F2 F3
If the mux is enabled, press the key to scroll the available ports into view. You may see Port1, Port2, Port3, Port4, or All. For information on selecting All, refer to Selecting All Ports later in this section.
To select a port, press the appropriate function key (F1 or F3).
This screen does not appear if in Singleport mode or the DTE Bridge configuration option is enabled.
Now go to the next screen (Data Stream).
DCP Operation

Data Stream Port1 Disable
F2 F3
The port field (for example, Port1) displays the selected port.
The available Data Stream action (Disable or Enable) appears on the second line of the LCD beside the port field. If the modem’s data transmitter is enabled, the word Disable appears to indicate that you may disable the data transmitter by selecting this action.
To change the modem’s data stream, press the F2 key. When the message Command Complete appears, press the key to clear the message.
Data Stream Port1 Enable
F2 F3
To change the data stream for the selected port again, press the F2 key.
To exit this function and remain in the Control branch, press the key. To exit and return to the Top-Level menu, press the key.
Selecting All will enable or disable the modem’s data transmitter function on all ports.
Select DS Port > Port1 All
F2 F3
From the Select DS Port screen, press the F3 key to select All.
Data Stream All Enable Disable
F1
To enable or disable the modem’s data transmitter function on all ports, press the appropriate function key, F1 (Enable) or F3 (Disable). When the message Command Complete appears, press the key to clear the message.
or · Selecting All Ports

Select DS Port > All
F2 F3
To change the data stream on all ports again, press the F1 key.
To exit this function and remain in the Control branch, press the key. To exit and return to the Top-Level menu, press the key.
This function allows the front panel EIA LEDs to display and change the activity of a selected digital interface. Use the EIA LEDs function to change the port that controls the front panel LED.
Based on the modem’s configuration, the following conditions exist:
To access EIA LEDs from the Control branch, make the following selections:
F2 F3
Press the key until EIA LEDs appears. Select EIA LEDs.
EIA LEDs:xxxxx > Port1 Port2
F2 F3
The port field (xxxxx) displays the currently selected interface. Valid interface selections are Port1, Port2, Port3, Port4, and depending on the set value of the Diagnostic Connection configuration option, CC (NMS Control Channel), or DC (Diagnostic Channel). Refer to Diag Connection configuration option in the Misc section of Chapter 4.
DCP Operation · or

Press the F1 key until the appropriate digital interface appears. Select the appropriate interface by pressing the corresponding function key.
After selecting the desired interface, the message Command Complete appears on the bottom line of the LCD and the selected interface appears in the xxxxx field.
The Port 1 interface is the only display allowed on the 3921Plus modem in Singleport mode, therefore the entire EIA LEDs branch is masked.
The Make Busy function forces the modem off-hook so it cannot answer a call. This is often used with PBX systems to permit the busy out of a PBX port for rotary or hunt groups.
To prevent violations of FCC and DOC regulations, this function must only be used behind a user’s PBX.
To access Make Busy from the Control branch, make the following selections:
F2 F3
Press the key until Make Busy appears. Select Make Busy.
Make Busy Command Complete
F2 F3
The modem is now in a forced busy condition. Command Complete appears on the LCD.
To remove the modem from Make Busy mode, press the key once and the key until RemoveMakeBusy appears.

F2 F3
Press any function key to select RemoveMakeBusy. The message Command Complete appears on the LCD.
The Service Line/Disconnect Service Line is only available in Models 3921-B1-001 and 3021-B1-011.
The Service Line function allows you to switch a specific Model 3921Plus installed in a COMSPHERE 3000 Series Carrier from normal leased or dial operation to service-line operation. This switch only places the modem on the service line. For a connection to be established, you must still use the normal dialing methods as described earlier in this chapter in the Call Setup Branch section.
A service line is an extra dial line connected to a COMSPHERE 3000 Series Carrier. This line is normally shared by up to four Model 3921Plus multiport or eight singleport modems installed in either Slots 1–8 or Slots 9–16. However, by daisy chaining the service-line connector of one Network Interface Module (NIM) to the service line of another NIM installed in the same carrier, you can permit eight multiport or sixteen singleport modems to share one service line. The service line can also be extended to other carriers in a cabinet. For more information on daisy chaining NIMs to the service line, refer to the COMSPHERE 3000 Series Carrier, Installation Manual.
A service line is ideal for a dial backup of Model 3921Plus modems operating on leased lines. Remember that a service line can back up only one failed leased line at a time.
To enable service line from the Control branch, make the following selections:
Press the key until Service Line appears.
F2 F3
Press F1 (Service_Line) to switch the modem from its normal dial line to the service line.
F2 F3
The message Command Complete appears. Now, when the modem places a call, instead of using the dial, the call is placed on the service line.
DCP Operation · Service_Line Command Complete

To disconnect the modem from the service line and resume normal operation, press the key (returning to Control branch). From the Control branch, press the key until DiscServiceLine appears.
F2 F3
Press F1 (DiscServiceLine). The call and service line disconnect and the message Command Complete appears.
The Download Software function sets parameters within the modem when transferring firmware to one or more modems or when receiving firmware upgrades from a locally attached PC-based controller. The latter is only performed by service representatives.
There are two selections under Download Software: Clone Remote and To Local via DTE. Clone Remote is used to transfer an exact copy of the firmware currently stored in a 392xPlus modem to either one or more remote 392xPlus modems or one or more DC-attached 392xPlus modems.
When implementing a Clone Remote operation, the following is true:
For more information on Clone Remote operation, refer to Implementing a Clone Remote Operation later in this section.
The second selection appearing on the LCD is To Local via DTE. This function permits firmware upgrades to be transferred to a 392xPlus modem. This type of download requires a locally attached PC controller to be connected to the modem’s DTE port as well as special download software. Any downloads using this selection are intended to be performed by service representatives only.
Clone Remote operations are not supported unless both local and remote modems are 392xPlus modems. (The 3800 or 391x Series modems cannot be used in cloning operations with 392xPlus modems.)
To access DwnLoadSoftware from the Control branch, make the following selections:
Selecting Clone Remote

F2 F3
Press the key until Download_Code appears. Press any function key to select Download_Code. The DwnLoadSoftware screen appears.
F2 F3
Press any function key to select Clone_Remote.
The next screen to appear is determined by the modem’s configuration. Refer to the appropriate section based on your modem’s configuration; Clone Remote in Point-to-Point Configurations, Clone Remote in Broadcast Configurations, or Clone Remote in Multipoint Configuration.
Clone Remote in Point-to-Point Configurations
Before using Clone Remote in point-to-point configurations, verify the following:
After completing these checks, proceed to the section titled Implementing a Clone Remote Operation, which follows the descriptions of multipoint cloning operations.
Clone Remote in Broadcast Configurations
A tributary modem configured for extended diagnostics (Diagnostic Connection configuration option set to Modem(DC)) can perform two types of Remote Clone operations. It can clone the upstream, VF connected, control modem (SC_Clone) or it can clone all the 392xPlus modems attached to its downstream Diagnostic Channel (DC_Broadcast).
Choose DLL Type > SC_Clone
F1
DCP Operation · DwnLoadSoftware > Clone_Remote

From the Choose DLL Type screen, press the F1 key to select SC_Clone to request the transfer of an exact copy of the tributary modem’s firmware to the VF connected control modem.
Proceed to the section titled Implementing a Clone Remote Operation, which follows the descriptions of multipoint cloning operations.
Cloning DC Broadcast Remote
Before using Clone Remote in DC Broadcast configurations, make sure the tributary modem’s active poll list contains all the network management addresses for the control modems that receive the download (refer to the Poll List Branch section in this chapter), and ensure that the control modems are responding properly to polls (refer to the Sub-Network Health and Status branch section in this chapter).
Choose DLL Type > DC_Broadcast
F2 F3
From the Choose DLL Type screen, press the key until DC_Broadcast appears. Press F1 or F2 to transfer an exact copy of the tributary modem’s firmware to the DC-connected control modem(s) using the Active Poll list.
Proceed to the section titled Implementing a Clone Remote Operation, which follows the descriptions of multipoint cloning operations.
Viewing DC Broadcast Clone Results
Choose DLL Type > DC_CloneResults
F2 F3
From the Choose DLL Type screen, press the key until DC_CloneResults appears to view the results of the last DC_Broadcast clone operation. If the message Trib List Empty appears, this indicates that a multiple download was never initiated.
DC Clone Results Nxt xxx Pass
F2 F3
The address field (xxx) displays the network management address of one of the remote modems. Pressing the F1 key allows you to select various remote modems to determine the download result for those modems (Pass or Fail).

Clone Remote in Multipoint Configurations
A Trellis Multipoint (TMp) control modem can be used to download firmware to just one tributary modem (Single) or to all of its tributary modems (Multiple).
A Trellis Multipoint (TMp) tributary modem cannot download firmware to its control modem. To download firmware to a TMp control modem use a point-to-point dial connection, an NMS, or a PC controller.
Before using Clone Remote in multipoint configurations (Single or Multiple), perform the following:
— the tributaries are responding properly to polls (this may take several minutes after the
control modem powers up). Refer to the Sub-Network Health and Status Branch section in this chapter for more information.
— the control modem’s active poll list contains all the network management addresses for
the remote 392xPlus tributary modems that will receive the download (refer to the Poll List Branch section in this chapter).
— all 391x modems are removed from the active poll list.
DCP Operation

Cloning a Single TMp Remote
Choose DLL Type > Single Multiple
F2 F3
Press the F1 key to select Single Clone Remote.
F2 F3
The address field (xxx) displays the network management address of the modem that receives the download. The valid address field range is from 001 to 256.
To increment digits within the address field (xxx), use the and keys to position the cursor ( _ ) under the digit to be incremented. Press the F2 () key to increment the digit.
Press F1 (Ent) to select the modem that will receive the download.
F2 F3
The password field (yyyyyyyy) displays the remote access password for the modem that will receive the download.
To increment digits within the password field (yyyyyyyy), use the and keys to position the cursor ( _ ) under the digit to be incremented. Press the F2 ( ) key to increment the digit.
Press Enter (Ent) to select the modem that will receive the download.
After completing these actions, proceed to the section titled Implementing a Clone Remote Operation.

Cloning a Multiple TMp Remote
Choose DLL Type > Single Multiple
F2 F3
Press the F3 key to select Multiple Clone Remote.
After completing this action, proceed to the next section titled Implementing a Clone Remote Operation.
Viewing Multiple TMp Clone Results
Choose DLL Type > MPtCloneResults
F2 F3
From the Choose DLL Type screen, press the key until the MPtCloneResults screen appears to view the results of the last multiple TMp clone operation. If the message Trib List Empty appears, this indicates that a multiple download was never initiated.
MPtCloneResults Nxt xxx Pass
F2 F3
The address field (xxx) displays the network management address of one of the remote modems. Pressing the F1 key allows you to select various remote modems to determine the download result for those modems (Pass or Fail).
DCP Operation

Implementing a Clone Remote Operation
The modem begins a transfer of its own program to the remote modem. This process takes the communication link out-of-service for a period of time depending on the data rate of the link. If the Clone Remote process is started and then interrupted, the remote modem is left in a partially programmed state in which its functional capabilities are limited to those required to initiate and complete another download attempt. If the mux is enabled when the Clone Remote process is interrupted, disable the mux on the source modem before you initiate another Clone Remote process. (Be sure to re-enable the mux when cloning is complete.)
F2 F3
At this point, if you do not want to continue this process, abort the transfer by selecting any function key. This returns the modem to the DwnLoadSoftware menu. However, to continue with the transfer, press the key to display the Reprogram_Remote selection.
F2 F3
Press any function key to begin the transfer.
RemClone Status Establish Remote
F1
The local modem’s LCD displays Establish Remote, indicating the modem is attempting to establish a Remote Cloning Download session with the remote modem.

If unsuccessful, the modem remains in the Download Transfer mode. The LCD’s top line displays RemClone Failed and the bottom line displays one of the following messages:
Incompat Modulat The modems are connected, but are using a modulation scheme other than V.34 family, V.33, V.32 family, V.29, or TMp.
No Response The remote modem is not a 3900 Series modem or the connection between the two modems is poor.
Access Disabled The remote modem’s Access from Remote configuration is disabled.
Password Invalid The local and remote modems’ passwords do not match. Correct the problem and attempt another download from the local modem. If this fails, contact your service representative.
No Circuit There is no connection between the local and remote modem.
After successful establishment of a Remote Cloning Download session, the following screens appear.
F2 F3
RemClone Status Bank1:xxxx/yyyy
F2 F3
As the firmware transfers, the local and remote LCD’s bottom line displays the status of the download process, plus the number of records sent versus the total number of records for that data bank number.
For Single download applications, if the download is successful, the local modem displays Remote Clone OK and the remote modem displays Frmware Upgrade. If the download took place over the dial network, the modems disconnect when the download is complete.
If the Single download is unsuccessful, RemClone Failed appears on the LCD’s top line. Attempt another download from the local modem. If this fails, contact your service representative.
DCP Operation · RemClone Status Initializing

New releases may be available for the 392xPlus modems. The latest 392xPlus firmware is available at no charge from the Automatic Firmware Download Center. Refer to page A in the front of this document for contact information.
To download the firmware, your modem must be configured for dialing. Save your modem’s current configuration to the Customer 1 or Customer 2 memory area, and load the Async Dial factory template (refer to Chapter 4, DCP Configuration, for more information about saving and changing configuration options).
If you have a DTE (terminal or PC) attached to your modem, informational messages appear on it when the modem connects. These messages show the amount of time the download will take. However, a DTE is not required.
The firmware download begins without any operator action. When the firmware download begins, the LCD displays download status messages with the data bank number, current block being loaded, and the total number of blocks.
F2 F3
If the modem connects at 14,400 bps, the download takes about 10 minutes. When the download completes, the modem resets itself and displays a normal status message (such as Idle:28.8).
Reload your saved configuration options from the Customer 1 or Customer 2 memory area.
Automatic Firmware Download Failure
If the firmware download is interrupted, the following screen appears.
F2 F3
This indicates that your modem is left in a state that can only be used to make or receive a call for download. To continue the firmware download, repeat the download process by directing the modem to dial the Automatic Firmware Download Center (refer to the Call Setup Branch section in this chapter for information about dialing a number using the DCP). If you are unable to complete the download, contact your service representative for assistance.
DownldOnly Mode Configure

The VF Thresholds Update function allows you to set the thresholds that determine the Health and Status alarm conditions for the VF parameters. Refer to Table 3-8 in this section for VF
thresholds and their valid ranges and default values.
To access VF_Thresh_Update from the Control branch, make the following selections:
F2 F3
Press the key until VF_Thresh_Update appears. Press any function key to select VF_Thresh_Update.
VF Thresholds Edit Save Reset
F2 F3
Select Edit.
In the following example, the RSL High threshold is changed from 09 (–dBm) to 10. This example demonstrates VF threshold editing and saving. With the exception of Signal Quality, all VF thresholds may be modified in this manner. Signal Quality uses a menu selection with possible values of Excelent (Excellent), Good, Fair, Poor, or No Signal. Editing and saving a VF threshold is similar to editing and saving a configuration option. (For another example of editing and saving, refer to the Editing and Saving a Configuration Option section in Chapter 4.)
RSL High (- dBm) Nxt 09
F2 F3
In the example shown above, 09 is the upper (High) RSL threshold (in –dBm). To change the 09 to 10, make the following selections:
RSL High (- dBm) Nxt 19
F1
F2 F3
Select the F2 ( ) key to increment the number above the cursor ( 0 ) to 1.
DCP Operation

RSL High (- dBm) Nxt 19
F1
F2 F3
Press the key to move the cursor to the next position ( 9 ).
Select the F2 ( ) key to change the number above the cursor ( 9 ) to 0.
RSL High (- dBm) Nxt 10
F2 F3
NOTE
If you want to modify additional VF thresholds, select Nxt.
To save the edited threshold(s):
RSL High (- dBm) Nxt 10
F2 F3
Press the key to scroll up to the Edit/Save screen.
VF Thresholds Edit Save Reset
F1
Select Save.

If the edited VF thresholds are valid, the Save command stores them into nonvolatile memory. When the Save completes, the message Save Completed appears.
Save VF Thresh Thd Out of Range
F2 F3
If the edited VF threshold is invalid (out of range), the error message Thd Out of Range appears. This indicates the Save procedure was unsuccessful. Return to the Edit screen and correct the invalid threshold range.
To correct the invalid VF threshold, press the key to return to the VF Threshold Edit/Save/Reset screen.
VF Thresholds Edit Save Reset
F2 F3
Select Reset to restore the original default values into memory.
Repeat the Edit and Save procedure until the VF threshold(s) is valid and the Save completes successfully (Save Completed).
To exit this function and remain in the Control branch, press the key. To exit and return to the Top-Level menu, press the key.
Health and Status VF alarms are reported to the front panel LED and the Network Management System (NMS) based on the parameters in Table 3-8. Refer to Table 3-6 in the Device Health and Status section of this chapter for Health and Status VF message alarm information.
VF Thresholds Valid Ranges Default Values
Receive Signal Level High 0 dBm to –15 dBm Above –9 dBm
Receive Signal Level Low –16 dBm to –50 dBm Below –23 dBm
Signal to Noise Ratio 5 dB to 40 dB Below 23 dB
Non-Linear Distortion 15 dB to 50 dB Below 30 dB
Retrains (per 15 minutes) 1 to 255 trains 15 trains
Signal Quality Excellent (lowest) Good Fair Poor No Signal (highest)
Near Echo 038 dBm Above –20 dBm
DCP Operation · Good

VF Thresholds Default Values Valid Ranges
Far Echo 0–38 dBm Above –20 dBm
Frequency Offset 1 Hz to 15 Hz Above 4 Hz
Phase Jitter 1 degree to 45 degrees Above 9 degrees
Phase Hits 1 to 255 hits 20 hits per 15 minutes
Impulse Hits 1 to 255 hits 20 hits per 15 minutes
Gain Hits 1 to 255 hits 20 hits per 15 minutes
Drop Outs 1 to 255 dropouts 20 dropouts per 15 minutes
The Test branch of the Top-Level menu allows you to initiate various modem tests. Use these tests if you are having data communication problems, such as periodic character loss, random errors, or constant format errors. By the process of elimination, you can usually isolate the fault in your system.
There are six selections under Test: Abort, Self (Self-Test), Loc Analog Loop (Local Analog Loopback), Rem Digital Loop (Remote Digital Loopback), Loc Digital Loop (Local Digital Loopback), and Pattern. The only tests that can operate concurrently on a single modem are Pattern with a Local Analog Loopback and Pattern with a Remote Digital Loopback. If any test is operating, besides the two combinations just mentioned, it must be canceled before starting another test.
The Test branch only initiates and cancels tests. If parameters need to be set, refer to the Tests section in Chapter 4.
Status Configure PList Control SubHS Call_Setup Tlk/Data Security Remote
Abort Self Loc_Analog_Loop Rem_Digital_Loop Loc_Digital_Loop Pattern
Port Select Port Select
“Status” · Test · Port Select

To access the Test branch from the Top-Level menu, make the following selections:
Leased:28.8 Control Test
F2 F3
Press the key until Test appears. Select Test.
Abort ends any test that is in progress and brings the modem back to the normal mode of operation. Confirmation is provided by the Command Complete message.
To access Abort from the Test branch, make the following selection:
F2 F3
Select Abort.
F1
F2 F3
The modem stops all tests currently in progress and displays the Command Complete status message on the LCD.
To exit this function and remain in the Test branch, press the key. To exit and return to the Top-Level menu, press the key.
DCP Operation

Self performs an internal self-test of the modem, which takes less than a minute to complete. The modem must be offline; otherwise, Invalid Command appears.
When this test is run in Remote mode, it causes the Remote mode session to be lost. The Remote mode session will reestablish after the self-test completes (usually one or two minutes). If the remote self-test fails, a Device Failure alarm message appears when the remote modem’s Device Health and Status (DeviceHS) branch is accessed.
To access Self from the Test branch, make the following selection:
F2 F3
Select Self. (All LCD cells and DCP status indicators light.)
The test delays 15 to 30 seconds to allow any outstanding network management messages to propagate before the VF channel is interrupted by the test.
If the modem passes the self-test, Pass appears on the LCD. If it fails, Failed appears. If the modem fails, contact your service representative. If Invalid Command appears, the modem is operating on dial lines. If OtherTestActive appears, another test is in progress. If another test is in progress, select Abort to clear the current test and try again. If the modem is operating on dial lines, disconnect to clear the dial lines, and then choose Self. If the modem receives a ring signal during this test, the test is canceled and RI Abort message appears.
To exit this function and remain in the Test branch, press the key. To exit and return to the Top-Level menu, press the key.

This test is not available when using V.34 modulation in Multiport mode.
Loc Analog Loop performs a local analog loopback (CCITT V.54 Loop 3), Figure 3-4, that verifies modem operation as well as the connection between the DTE and modem. The modem must be offline and in Synchronous or Asynchronous Direct mode to perform this test, otherwise Invalid Command appears.
If you are performing a Local Analog Loop test on a TMp modulation that is running a test pattern with a constant flow of data, you must toggle the RTS switch off and then on to allow the modem to train up.

To access Loc Analog Loop from the Test branch, make the following selections:
F2 F3
Press the key until Loc Analog Loop appears. Press any function key to start this test.
Test:Local Loop Started
F2 F3
DCP Operation

The test delays 15 to 30 seconds to allow any outstanding network management messages to propagate before the VF channel is interrupted by the test.
The message Started appears on the LCD, and the Test LED lights for the duration of the test. If OtherTestActive appears on the LCD, another test is in progress. Select Abort to clear the current test and try again. If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the test. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to the Test section in Chapter 4. A Ring Indicate during this test can cause errors.
To exit this function and remain in the Test branch, press the key. To exit and return to the Top-Level menu, press the key.
This test is not available when:
Rem Digital Loop performs a remote digital loopback (CCITT V.54 Loop 2), Figure 3-5. This test can verify the integrity of the local modem, the communication link, and the remote modem. Any data or pattern entered at the local DTE is sent to and returned from the remote modem. For this test to operate properly, the modems must be operating at the same rate and in Synchronous or Asynchronous Direct mode.


To access Rem_Digital_Loop from the Test branch, make the following selections:
F2 F3
Press the key until Rem_Digital_Loop appears. Press any function key to start this test.
Pick Test Port > Port1 Port2
F2 F3
Select the appropriate port by pressing the corresponding function key. Press the key to scroll other ports into view.
This screen does not appear in Singleport mode.
Test:P1:Rem Loop Started
F2 F3
The message Started appears on the LCD, and the Test LED lights.
If OtherTestActive appears on the LCD, another test is in progress. Select Abort to clear the current test and try again. If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the test. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to the Test section in Chapter 4.
To exit this function and remain in the Test branch, press the key. To exit and return to the Top-Level menu, press the key.
DCP Operation

Loc Digital Loop is issued by a local modem and forces it to loopback any data received from the remote modem (Figure 3-6 ). (This test operates the same as a CCITT V.54 Loop 2 except it is issued at your modem.) This is useful if a remote modem is incapable of initiating a remote digital loopback from its location. For this test to operate properly, the modems must be operating at the same rate and in Synchronous or Asynchronous Direct mode.
A TMp tributary cannot perform a local digital loopback test.

To access Loc_Digital_Loop from the Test branch, make the following selections:
F2 F3
Press the key until Loc_Digital_Loop appears. Press any function key to start this test.
Pick Test Port > Port1 Port2
F2 F3
If the mux is enabled, select the appropriate port by pressing the corresponding function key. Press the key to scroll other ports into view.

This screen does not appear in Singleport mode.
Test:P1:Dig Loop Started
F2 F3
The message Started appears on the LCD and the Test LED lights. The port field (for example, P1 for Port 1) displays the port that is currently selected. You may see P1, P2, P3, or P4.
If OtherTestActive appears on the LCD, another test is in progress. Select Abort to clear the current test and try again. If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the display. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to the Test section in Chapter 4.
To exit this function and remain in the Test branch, press the key. To exit and return to the Top-Level menu, press the key.
Pattern can transmit and receive a 511 bit error rate test pattern. It can also be used with a currently running local analog loopback or a remote digital loopback to simulate data passing through the modem. You will need to start the local analog or remote digital loopback test before you start the pattern test. For this test to operate properly, the modems must be online and in Synchronous or Asynchronous Direct mode. Otherwise, the message Invalid Command appears when this test is started (Figures 3-7 through 3-9).

DCP Operation



To access Pattern from the Test branch, make the following selections:
F2 F3
Press the key until Pattern appears. Select Pattern to start this test.

Pick Test Port > Port1 Port2
F2 F3
Select the appropriate port by pressing the corresponding F key. Press the key to scroll other ports into view.
The Pick Test Port screen does not appear in Singleport mode.
Test:P1:Pattern Started
F2 F3
The message Started appears on the LCD and the Test LED lights.
The port field (for example, P1 for Port 1) displays the port that is currently selected. You may see P1, P2, P3, or P4.
Test P1:Pattern > BlksErrd=xxxxxxx
F2 F3
BlksErrd=xxxxxxx displays the number of blocks of data found in error (block size is 1000 bits per block). BlksRcvd=xxxxxxx displays the total number of blocks of data received. Select Clear to reset both block counters. In Singleport mode the message NoSync can appear as a value for BlksErrd while the modem’s receiver is synchronizing. The message OvrFlw can appear as the value for BlksErrd if the counter overflows.
Press the key to display BlksRcvd=xxxxxxx, number of blocks of data received.
Press the key to display Clear. Select Clear to reset the block counters.
The Pattern test can be exited and reentered without restarting the test. The BlksErrd and BlksRcvd continue counting.
If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the test. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to the Test section in Chapter 4.
To exit this function and remain in the Test branch, press the key. To exit and return to the Top-Level menu, press the key.
DCP Operation

The Sub-Network Health and Status (SubHS) function is not available on multipoint tributary modems or with certain modulations (V.29, V.33, V.22bis, and V.27bis).
The SubHS branch of the Top-Level menu allows you to display alarm conditions in downstream modems.
Status Configure Plist Control Test Call_Setup Tlk/Data Security Remote
To access the SubHS branch from the Top-Level menu, make the following selections:
Leased:28.8 Test SubHS
F2 F3
Press the key until SubHS appears. Select SubHS.
If there are no modems in the poll list, the message Poll List Empty! appears on the second line of the LCD.
Sub-network HS Nxt xxx yyyyyy
F2 F3
“Status” · SubHS

When you select SubHS,
xxx Displays the network management address of the downstream modem selected.
yyyyyy Displays the status of the downstream modem. This message is updated every several seconds to display the latest status. MAJOR, MINOR, and STATUS display Health and Status alarm conditions; refer to Table 3-6 in the Device Health and Status (DeviceHS) section of this chapter for additional information. UNKNWN appears when the modem does not recognize the downstream health and status information or device communication is not established. Normal appears if no alarms are present. NO RSP appears when the downstream modem does not respond to the poll.
Select Nxt to scroll through the entries in the poll lists.
To exit this function and return to the Top-Level menu, press the key.
The Call Setup function is not available in TMp Control mode.
For dial backup applications, the Call Setup branch of the Top-Level menu allows you to dial, disconnect, and answer telephone calls. For leased backup applications, the Call Setup branch allows you to switch between the primary leased line and the backup leased line.
In leased backup operation, a 2-wire leased line is used as the backup facility instead of the normal 2-wire dial line. Plug the leased line into the jack labeled DIAL on the rear panel of the modem (see Figure 2-1 in Chapter 2), and enable the Dual_Leased_Ln configuration option. (Refer to the Leased Line section in Chapter 4 for configuration options.) Except for dialing, ring indication, and call progression functions, you control the backup function as if it were a normal dial backup.
Status Configure PList Control Test SubHS Tlk/Data Security Remote
Dial Disconnect Answer Dial_Standby
(Does not appear in North America)
Directory Locations 1 - 24

To access the Call Setup branch from the Top-Level menu, make the following selections:
Leased:28.8 Call_Setup
F2 F3
Press the key until Call_Setup appears. Select Call Setup.
For dial backup applications, Dial allows you to dial any telephone number stored in directory locations 1–24. Any telephone number dialed using the DCP must already exist in a directory location. Refer to Change Directory for information on storing telephone numbers in directory locations.
For leased backup applications, Dial allows you to switch to the backup leased line. Any valid non-empty directory location may be used. The remote modem cannot automatically answer the simulated call. Use the Answer function of the remote modem in conjunction with the Dial function to manually switch to the backup leased line.
To access Dial from the Call Setup branch, make the following selection:
F2 F3
Select Dial to display the first directory telephone number.
F2 F3
To view other directory locations, select Nxt.
F2 F3
Once the directory location you want appears on the LCD, press the F2 or F3 key to dial the number.

DialDirectory:01 Off Hook
F2 F3
The Call Setup status Off Hook appears during the connection process.
If the connection is successful, the modem is online and one of the Normal Operation status messages (Table 3-3) appears on the LCD. If the connection is not successful, the LCD displays one of the Call Failure status messages (Table 3-3).
For dial backup applications, use this function when you want to disconnect an established call on a dial line. For leased backup applications, use this function to switch between the primary leased line and the backup leased line.
To access Disconnect from the Call Setup branch, make the following selection:
F2 F3
Select Disconnect.
F2 F3
For dial backup applications, the modem goes on-hook (hangs up) and the call is disconnected. The Command Complete status message appears.
To exit this function and remain in the Call Setup branch, press the key. To exit and return to the Top-Level menu, press the key.
DCP Operation · Disconnect Command Complete

For dial backup applications, Answer allows the modem to go off-hook, generate an answer tone, and begin the handshaking process with the calling modem. Use the Answer function when the Auto-Answer Ring Count configuration option is disabled. (Refer to the Line Dialer section in Chapter 4.)
For leased backup applications, Answer allows the modem to begin a “handshake” process with the remote modem.
To access Answer from the Call Setup branch, make the following selections:
F2 F3
Press the key until Answer appears. Select Answer.
F2 F3
The modem goes off-hook and attempts to establish a connection in Answer mode. The Command Complete status message appears on the LCD.
To exit this function and remain in the Call Setup branch, press the key. To exit and return to the Top-Level menu, press the key.
When the modem is operating in Dial Backup mode (DialBckUp), Dial Standby and Return to Dial allow the modem to switch between primary leased-line and primary leased-line backup operation while still maintaining the backup connection (Figure 3-10). Switching between backup and primary leased-line operation can be performed manually or automatically. (Refer to the Leased Line section in Chapter 4 to enable the Automatic Dial Backup configuration option.)

Figure 3-10. Dial Backup
Answer Command Complete · 496-13081-01

Under normal backup conditions, when a problem occurs on the primary leased line, the modems establish a connection over the backup network.
F2 F3
When this occurs, the Dial Standby function appears on the LCD. If you select Dial Standby, the modem switches back to the primary leased-line while still maintaining the backup connection. As a result, the Return_to_Dial function appears on the LCD instead of Dial Standby.
F2 F3
If the primary leased line is unacceptable, select Return_to_Dial which switches the modem back to backup network operation (LCD displays Dial Standby). If however, the primary leased-line is operating properly, you can select Disconnect from the Call Setup branch to drop the dial backup connection. Also, if the primary leased-line operation is maintained uninterrupted amount of time specified in the Dial Standby configuration option, the dial backup network disconnected.
To access Dial Standby or Return to Dial from the Call Setup branch, make the following selections:
F2 F3
Press the key until Dial Standby or Return_to_Dial appears. Select the appropriate function.
Dial Standby Command Complete
F2 F3
If the modem is operating in a Dial Backup mode, the Dial Standby function forces the modem to primary leased-lines and the LCD displays the status message Command Complete.
Once the modem is in Dial Standby mode, Return_to_Dial appears on the LCD. Selecting this function forces the modem to backup networks and the LCD displays the status message Command Complete.
DCP Operation

Change Directory allows you to enter or modify telephone numbers. The modem has nonvolatile memory locations that allow you to store up to 24 telephone numbers. Each directory location can accept up to 40 characters; this includes the telephone number and dial command modifiers. Any telephone number dialed using the DCP Dial command must appear in a directory location.
If the modem is operating on leased lines and has a dial line attached for dial backup purposes, it is required that directory location 1 contain the telephone number used for dial backup.
To access Change Directory from the Call Setup branch, make the following selections:
F2 F3
Press the key until Change_Directory appears. Press any function key to select Change_Directory.
01:551234 Nxt
F2 F3
The phone number listed in directory location 1 appears. Select Nxt to display other directory locations.

Entering Telephone Numbers and Dial Command Modifiers into Directory Locations
The following example uses an empty directory location for describing how to enter a telephone number. If you want to change an existing telephone number in any of the 24 directory locations, follow the same procedures.
To add a telephone number to a directory location, make the following selections:
F2 F3
Select Nxt until a blank directory appears on the LCD. (The cursor ( _ ) always appears in the first character position.)
Select F2 ( ) or F3 ( ) until the desired character is selected. This can be an alpha or numeric character.
F2 F3
Press the key to move the cursor to the next character position.
Continue this key sequence until the dial command modifiers and telephone number are entered. (Refer to Table 3-9 for a list of valid dial command modifiers.)
01:9W5556789 Nxt
F2 F3
To save the number just entered, scroll to the next directory location by selecting Nxt. The number is now stored in nonvolatile memory.
Table 3-9 describes what can be entered in directory locations.
DCP Operation

Dial command modifiers are parameters entered in the dial command string which specify how, when, and what number to dial. The following is a list of parameters the 392xPlus modems recognize:
T — Tone (DTMF) dial. Any digit 0–9, *, or # can be dialed as tone.
P — Pulse dial. Only the digits 0–9 can be dialed in Pulse Dial mode.
string. The modem defaults to the value set by the Dialer Type configuration option.
, — Pause. Causes the modem to pause before processing the next character in the dial string. The length of
this pause is determined by the setting of the Pause Time configuration option (refer to the Line Dialer configuration option group) or by the value held in S-Register S8.
W — Wait for tone dial. The modem waits for a second dial tone before processing the dial string. This can be the
initial dial tone or can be used when dialing through a tandem PBX.
R — Reverse Dial mode. Causes the originating modem to send out an answertone once it no longer detects
ringback. (Ringback is the ring you hear at the originating site when making a call.) The R modifier must be the last character in the dial string.
@ — Quiet answer. Wait for five seconds of silence after dialing the number. If the silence is not detected, the
modem sends the NO ANSWER result code to the DTE or displays the No Quiet Answer LCD status message.
! — Hook flash. Causes the modem to go on-hook for 0.5 seconds then return to off-hook.
; — Return to Command mode. Causes the modem to return to Command mode after dialing a number without
disconnecting the call.
Space — Ignored by the dial string, can be included to enhance readability.
– — Ignored by the dial string, can be included to enhance readability.
+ — Ignored by the dial string, can be included to enhance readability.
( ) — Ignored by the dial string, can be included to enhance readability.
← — End of Number. Hides all characters appearing on the LCD entered to the right of this indicator.
Directory Status displays the status of each directory location.
To access Directory Status from the Call Setup branch, make the following selections:
Press the key until Directory_Status appears. Press any function key to select Directory_Status.
F2 F3
Press the key until Directory_Status appears. Press any function key to select Directory_Status.

Number Status Nxt 01:Allowed
F2 F3
Select Nxt to display other directory locations.
The status of a directory location can be:
No Number The directory location is empty.
Allowed The number in this directory location may be dialed at this time.
Delayed The number in this directory location may be dialed later.
Forbidden The number in this directory location may not be dialed.
Delayed and Forbidden only appear in countries with specific dialing requirements.
When a number is delayed, press the key to display the value of the delay in minutes.
The delayed and forbidden conditions can be cleared by power cycling the modem. This is actually the only way to re-enable a forbidden number. Deleting a number from a directory location and reentering it into another directory location will not change the delayed or forbidden condition of this number.
The Talk/Data function is not available in TMp Control mode.
The Talk/Data branch of the Top-Level menu allows you to switch the modem between Talk mode and Data mode when manually dialing using either the DCP or an externally attached telephone.
To add an external telephone to your modem, use an external “Y” cable to connect the phone line to both the modem and the telephone (refer to Appendix C). This cable is not supplied with your modem.
On initial power-up, the modem is in Data mode. When in Data mode, the modem is connected and data can be transmitted or received. When in Talk mode, the modem is disconnected and you are free to use the external telephone. This function is not available for Model 3921Plus modems.
Status Configure PList Control Test SubHS Call_Setup Security Remote
DCP Operation · “Status” · Tlk/Data

The following sections describe the uses of the Talk/Data function.
NOTE
On the remote modem, the Line Current Disconnect configuration option (refer to the Line Dialer section in Chapter 4) must be set to Disable.
This configuration option does not appear on Models 3920-A1-401, 411 and 3921-B1-001, 011.
If you are originating a call using a telephone and the remote modem is configured for Auto-Answer, perform the following procedure.
Idle:28.8 Tlk/Data
F2 F3
Press the key until Tlk/Data appears.
Lift the attached handset and dial the telephone number of the remote modem. When the remote modem answers, it transmits an answer tone.
Idle:28.8 Tlk/Data
F2 F3
When you hear this tone, immediately select Tlk/Data and hang up the handset. This starts the handshaking sequence between your modem and the remote modem.
Online:28.8 > Call_Setup
F2 F3
If this is successful, the modems are in Data mode and OnLine appears on the LCD.

NOTE
On both modems, the Line Current Disconnect configuration option (refer to the Line Dialer section in Chapter 4) must be set to Disable.
If you are originating a call using a telephone and the remote modem is configured for Manual Answer, perform the following procedure.
Once the remote telephone is answered by the remote user, you must both decide when to place the modems into Data mode. You must both select Tlk/Data at approximately the same time and hang up the handset to begin the handshaking sequence.
If the handshake is successful, the modems are in Data mode and OnLine appears on the LCD.
If the remote modem is not a 3900 Series modem, then the remote user must consult that modem’s operator’s manual to perform a similar operation.
Once the modems are online, the status messages listed in Table 3-3 appear on the Top-Level display.
It is not necessary to specify an originating or answering modem when dialing via the DCP because the answering modem detects that it is receiving a ringing voltage and automatically defaults to Answer mode.
The Security branch is only available in Singleport mode. The Security branch allows you to create, edit, and save parameters that determine how the modem’s security is executed. For security procedures and configuration options, refer to Chapter 6, Dial Access Security.
DCP Operation

The Remote branch of the Top-Level menu allows you to control the remote modem’s DCP using the local modem’s DCP. This function allows you to change configuration options and control test functions in a remote modem. Any changes made to configuration options while using the Remote branch are not saved until you exit the Remote branch. This function is only available when using either V.34, V.33, V.32 terbo, V.32bis, V.32, TMp, or V.29 modulation schemes.
Status Configure Plist Control Test SubHS Call_Setup Tlk/Data Security
Choose Address (TMp Control only)
Choose Password
(TMp only)
(Not in TMp Trib)
Secondary Prim (data blckd)
(ExitRem appears instead of Remote when
using Remote Mode)
The following conditions must be met before using the Remote branch:
“Status” · Remote

Remote DCP access is accomplished using either the primary or secondary channel (if available) of the VF line. Using the primary channel gives a much faster response time due to the higher data rate, but it also interrupts data flow because primary data is stopped when Remote mode is active. Once Remote mode is terminated, the primary channel is automatically made available for data transmission.
Unlike primary channel communications, the secondary channel operates at a slower data rate and does not interrupt data flow. (V.34, V.32 terbo, V.32bis, V.32, and TMp are the only modulations available for the secondary channel.)
When initiating a Remote function from a TMp tributary modem, primary channel operation is not available. Also, if the tributary modem is not on the control modem’s poll list, the error message No Trib Session appears when the function is executed.
To access the Remote branch, make the following selections:
Leased:28.8 < Security Remote
F2 F3
Press the key until Remote appears. Select Remote.
If a connection is not established between a local 3900 Series modem and a remote 3900 Series modem, the LCD displays Remote Mode Fail–No Circuit. Return to the Top-Level menu.
For Trellis Multipoint (TMp) control modems, you must specify the network management address of a tributary modem. The following display does not appear in point-to-point or Trellis Multipoint tributary modems.
F2 F3
The address field (xxx) displays the network management address of the modem to be accessed by the Remote function. The valid address field range is from 001 to 256.
To increment digits within the address field (xxx), use the and keys to position the cursor ( _ ) under the digit to be incremented. Press the F2 ( ) key to increment the digit.
Press Enter (Ent) to select the modem that will be accessed by the Remote function.
DCP Operation

For Trellis Multipoint (TMp) modems (control or tributary), you must specify the remote access password of the modem that will be accessed by the Remote function. The following display does not appear in point-to-point modems.
F2 F3
The password field (yyyyyyyy) displays the remote access password of the modem to be accessed by the Remote function.
To increment digits within the password field (yyyyyyyy), use the and keys to position the cursor ( _ ) under the digit to be incremented. Press the F2 ( ) key to increment the digit.
Press Enter (Ent) to select the modem that will be accessed by the Remote function.
Select Channel > Secondary
F2 F3
Select Channel < Prim (data blckd)
F2 F3
If operation over the secondary channel is desired, press any function key to select the secondary channel. Secondary channel only appears if using V.34, V.32 terbo, V.32bis, V.32 or TMp modulation. If operation over the primary channel is desired, press the key until primary displays and press any function key. Primary channel operation is not available when initiating a Remote function from a TMp tributary modem.
or

Leased:28.8 Control ExitRem
F2 F3
If the remote modem accepts the password and the entry is successful, the Top-Level menu of the remote modem appears on the local modem’s LCD. An appears in the upper right-hand corner indicating that what is displayed on your LCD is actually the Top-Level menu of the remote 392xPlus modem. If the message Remote FP Busy appears, the remote modem’s front panel is already in Remote mode.
Configure PList Control Test SubHS Call_Setup ExitRem
The Top-Level menu of the remote 392xPlus modem is similar to the local 392xPlus modem with the following exceptions:
To return to local modem operation, select ExitRem. Any changes made to configuration options in the remote modem are saved.
The following conditions can cause Remote branch access to fail:
DCP Operation · “Status” · Status

NOTE
This page of the manual is self supporting and can be removed to prevent unwanted knowledge of the DCP security access selections.
Use the DCP security access function to “lock” the DCP of any 392xPlus modem and prevent unwanted user access. Two options are available for this function: Grant and Deny.
Grant allows any branch of the Top-Level menu to be accessed from the DCP. Deny only allows access to the Status branch of the Top-Level menu. All 392xPlus modems are shipped from the factory with DCP access granted.
To access the Front Panel (DCP) Security Access function, perform the following:
Press the key three times.
Press the key twice.
Press the key once.
Frnt Panl Acces Grant Deny
F2 F3
Select Grant to allow access or select Deny to lock DCP access.
Either selection results in a return to the Top-Level menu.
DCP Operation

Overview 4-1 Configure Branch 4-3 Editing and Saving a Configuration Option 4-4 Summary 4-7 Configuration Tables 4-8 Multiport Mode 4-8 DTE Interface 4-10 Line Dialer 4-19 Dial Line 4-22 Leased Line 4-24 Test 4-27 Misc 4-28 Singleport Mode 4-31 DTE Interface 4-33 DTE Dialer 4-41 Line Dialer 4-46 Dial Line 4-50 Leased Line 4-53 V.42/MNP/Buffer 4-58 Test 4-64 Misc 4-66 Security 4-68
After installing a 392xPlus modem, its software configuration options must be set using the diagnostic control panel (DCP). This chapter describes how to access and use the Configure branch of the Top-Level menu via the DCP.
The Configure branch accesses the Edit Area which is a work space where you view and change the configuration options. These configuration options are loaded to the Edit Area from one of five configuration option areas: Active (Operating), Active (Saved), Customer 1, Customer 2, or Factory.

Figure 4-1 graphically displays the interaction between the edit area and configuration areas as viewed from the perspective of the DCP.
CONTENTS OF Active (Saved) ARE AUTOMATICALLY COPIED TO Active (Operating) WHEN A SAVE IS COMMANDED VIA THE DCP, ON A RESET, OR ON POWER-UP.
Active (Operating) Active (Saved) Customer1 Customer2 Factory
(Answer/Originate) Async Leased*
(Answer/Originate) TMp (Control/Trib) Async Dial Sync Dial* UNIX Dial
Load Edit Area From
EDIT AREA ALLOWS YOU TO VIEW AND EDIT CONFIGURATION OPTIONS
ANY CHANGES MADE TO CONFIGURATION OPTIONS ARE SAVED TO Active (Saved), Customer1, OR Customer2

The Configure branch of the Top-Level menu contains all of the modem’s configuration options which determine how the modem operates. These configuration options are accessed by scrolling down and across various levels of the Configure branch.
Status PList Control Test SubHS Call_Setup Tlk/Data Security Remote
Ld EditArea frm:
Activ (Operating) Active (Saved) Customer1 Customer2 Factory
Active (Saved) Customer1 Customer2
DTE_Interface Line_Dialer Leased_Line Test Security
DTE_Dialer Dial_Line V42/MNP/Buffer MIsc
MUX Copy Port1 Port2* Port3* Port*
Rate* Async EIA
*Not shown when the DTE Bridge configuration option is enabled.

The Configure branch consists of the following three levels:
The following example shows how to change the Remote Access Password using the DCP. (If you intend to access another 392xPlus modem via the Remote branch of the Top-Level menu, the Remote Access Password must be the same for both modems.) By following these procedures you learn how to load a factory preset configuration area (in this case, Sync Leased), how to edit a configuration option (Remote Access Password), and how to save changes to a configuration area (Active (Saved)). The shaded key indicates what key to press.
Leased:28.8 Status Configure
F1
Select Configure from the Top-Level menu.
F2 F3
F1
F2 F3
Scroll across the LCD and select the Factory configuration area.
LdEditAreafrm > Activ(Operating) · LdEditAreafrm < Factory

F2 F3
Select Sync_Leased.
F2 F3
Select Answer.
F2 F3
Select Edit.
F2 F3
Edit StrapGroup Test Misc
F2 F3
Scroll across the LCD and select the Misc configuration options group.
DCP Configuration

StrapsWhenDisc > Nxt No_Change
F2 F3
F1
Select Nxt until RemAccssPasswrd appears.
F2 F3
Select the F2 ( ) key to increment password values.
F2 F3
Press the key to move the cursor to the next position.
F2 F3
Continue this sequence until you have entered the new password value.

To save the new password to a configuration area, make the following selections:
F2 F3
Press the key to scroll up (twice).
Choose Function Edit Save
F2 F3
Select Save.
Sav EditArea to > Active(Saved)
F2 F3
Select a configuration area (Active (Saved), Customer 1, or Customer 2) to save the changes.
Select the key to exit to the Top-Level menu or select the key to remain in the Configure branch.
When using the DCP to edit configuration options, keep the following in mind:
DCP Configuration

Each modem operates in either the Multiport or Singleport mode depending on the modem’s configuration (refer to 392xPlus Operational Modes in Chapter 1).
The modem’s configuration options are arranged into six groups in the Multiport mode, and nine groups in the Singleport mode. When using configuration option tables, be sure you are referencing the correct group (Multiport or Singleport mode). Failure to do this may lead to erroneous assumptions about the functionality of certain configuration options.
The star symbol indicates configuration option groups which are valid in Multiport mode.
The solid arrow indicates configuration option groups which are valid in Singleport mode.
Throughout these tables, two selections frequently appear on the LCD: Enable and Disable. Unless otherwise stated, Enable selects a configuration option and makes it available for use; Disable makes a configuration option unavailable for use.
In some countries, the range of allowable values for some configuration options is restricted. The modem accepts any selection, but sets the configuration option to the closest legal value. The actual value accepted by the modem appears when the F2 key is pressed to enter a selection.
The remainder of this chapter discusses each Multiport and Singleport mode configuration option group in detail.
The Multiport mode’s configuration options are arranged by functionality into the following:
The following graphic represents the structure of the configuration options in Multiport mode.

V.42/ MNP/ Buffer
AutoAnswerRing# Dialer Type DialTone Detect Blind Dial Paus BusyTone Detect "," Pause Time NoAnswer Timout Fast Disconnect Line Crnt Disc Long Space Disc No Carrier Disc No Data Disc Auto Make Busy
Dial Modulation Dial Line Rate Autorate V32bis Override Dial Tx Level Train Time Asymmetric Rate
LeaseModulation LeasedLine Rate Leased Mode Autorate V32bis Override Leased Tx Level Asymmetric Rate Auto Dial Back AutoDialStandby SpecialStandby DialStandbyTime CarrierOn Level Lease Lookback Dual_Leased_Ln BackupLine Check
Test Timeout V54 Address V54 Device Type
StrapsWhenDisc Speaker Control Speaker Volume Access frm Remt RemAccssPasswrd Dir#1_Callback NMS_Call_Msgs NetworkPosition NetMngmtAddress Diag Connection Link Delay(sec)
Port 1 Port 2* Port 3* Port 4*
MUX Mode –TDM/MSD –DTE Bridge Tx Clock Source Bakup_TXClk_Src CT111_Rate Cntl MSD Port Control
To Port X or All
Modem MSD Rate at 33.6 K Rate at 28.8 K Rate at 24.0 K Rate at 19.2 K Rate at 16.8 K Rate at 14.4 K Rate at 12.0 K Rate at 9600 Rate at 7200 Rate at 4800 Rate at 2400
Async/Sync Async DTE Rate Asyn #Data Bits Asyn #Stop Bits Async OverSpeed
DTR Action DSR Control RTS Action RTS Antistream CTS Control RTS/CTS Delay LSD Control XTXC Clamps TXC CT111 Control Rcv Remote Loop DTE RL (CT140) DTE LL (CT141) Port TXC Source DTE Alarm Mask Extend Main Ch. Upstream Port
*Not shown when the DTE Bridge configuration option is enabled. 495-14623-01
The DTE Dialer, V.42/MNP/Buffer, and Security branches are not available in Multiport mode.

DTE Interface — Multiport Mode
The DTE Interface configuration options contain EIA-232-D (CCITT V.24) and asynchronous character format information essential for maintaining a connection and for transmitting data between the DTEs and the modem.
Table 4-1 shows each DTE Interface configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is newly installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 9) DTE Interface Configuration Options — Multiport Mode
Mux Mode. Determines the operating mode of the multiplexer (mux).
Appendix B, Troubleshooting.
TDM/MSD – Enables the modem as a time division multiplexer (TDM) and a modem sharing device (MSD). When the Mux mode configuration option is set to TDM/MSD, and at least one port has the MSD Mode setting enabled, then the MSD is enabled. Only the lowest numbered port in an MSD group allows strapping of the port rate, which will only be used when V.34 or V.32 modulation is active. For example, a tributary running TMp modulation will have the port rate equal to the line rate. The lowest numbered port on the control modem is recommended as the MSD output port.
Disable – Disables MUX Mode on the modem. Refer to the Singleport Mode section in this chapter for the mux disabled configuration options.
DTE Bridge – Enables the modem as a digital bridge for dial backup of a multipoint configuration by bridging the signal on the digital side of the Front End Processor (FEP) modems. In this configuration, only two ports can be used on the control and backup modems (both on the FEP side). Data received on Port 1 is transmitted across the communication link and looped back through Port 2. Data received across the communication link and on Port 2 is sent through Port 1.
Transmit Clock Source. Determines the source of timing for synchronous data transmitted from the modem to the analog channel.
Internal – The transmit data’s clock source is derived from the modem’s internal clock. This clock is available as an output on Pin 15 (TXC) of the EIA-232-D interface.
Receive Clock Loop – The modem’s transmit clock is derived from its received analog signal. The derived clock is available as an output on Pin 15 (TXC) of the EIA-232-D interface.
Port1 – The transmit data’s clock source is provided on Pin 24 (XTXC) of the EIA-232-D interface for Port 1.
Port2 – The transmit data’s clock source is provided on Pin 24 (XTXC) of the EIA-232-D interface for Port 2.
Port3 – The transmit data’s clock source is provided on Pin 24 (XTXC) of the EIA-232-D interface for Port 3.
Port4 – The transmit data’s clock source is provided on Pin 24 (XTXC) of the EIA-232-D interface for Port 4.

(2 of 9) DTE Interface Configuration Options — Multiport Mode
This configuration option only appears when Dual_Leased_Ln is configured for Enable.
Backup Transmit Clock Source. Selects the clock reference source when operating in the Dual Leased Line Mode. This is a special mode in which one leased line is used to back up another.
Internal – The transmit data’s clock source is derived from the modem’s internal clock. This clock is available as an output on Pin 15 (TXC) of the EIA-232-D interface.
Receive Clock Loop – The modem’s transmit clock is derived from its received analog signal. The derived clock is available as an output on Pin 15 (TXC) of the EIA-232-D interface.
Port1 – The transmit data’s clock source is provided on Pin 24 (XTXC) of the EIA-232-D interface for Port 1.
Port2 – The transmit data’s clock source is provided on Pin 24 (XTXC) of the EIA-232-D interface for Port 2.
Port3 – The transmit data’s clock source is provided on Pin 24 (XTXC) of the EIA-232-D interface for Port 3.
Port4 – The transmit data’s clock source is provided on Pin 24 (XTXC) of the EIA-232-D interface for Port 4.
This configuration option does not appear when V.34 is enabled for a leased or dial line.
CT111 Rate Control. Allows the DTEs to control modem rate via Pin 23 of the EIA-232-D interface. This configuration option determines the effect of the DTE Rate control signals. CT111 is also known as CH on the EIA-232-D interface.
Disable – Disregards all CT111 Rate Control.
Fallback1 – Forces the modem to decrease its configured data rate to the next lower data rate when any of the CT111 signals are OFF. When all of the CT111 signals are ON, the modem returns to its previous data rate.
Fallback2 – Forces the modem to decrease two data rates (while remaining in the same modulation scheme) when any of the CT111 signals are OFF. When all of the CT111 signals are ON, the modem returns to its previous data rate. Note, Fallback2 is not available for TMp tributaries.
This configuration option does not appear when MSD is disabled.
Modem Sharing Device Port Control.
Host – The host computer determines the polling sequence that controls which port transmits at any given time. When the DTE/DCE equipment attached to a port raises RTS (Request-to-Send) it gets to use the channel. If more than one port raises RTS at the same time, the transmission on the channel is garbled. The system protocol ensures that only one port transmits data at a time.
Modem – The modem determines the polling sequence that controls which port transmits at a given time. The first port to raise RTS will receive CTS (Clear-to-Send) authorization to transmit data. When the current transmitting port lowers its RTS, the modem randomly polls another port with RTS raised.
DCP Configuration

(3 of 9) DTE Interface Configuration Options — Multiport Mode
This configuration option only appears when NetworkPosition is configured for Tributary.
Modem Modem Sharing Device. Disables or enables the MSD function on a per-port basis.
if Modem MSD is enabled for Ports 2, 3, and 4, only Port 2 rates are available.
option is disabled.
Rate at 33.6 K Nxt Disable 33600 28800 24000 19200 16800 14400 12000 9600 7200 4800 2400 1200
Rate at 33.6K. When the modem rate is 33,600 bps the port rate will be as selected by this configuration option (Disable or 33600 to 1200). The total for all ports cannot exceed the modem rate of 33,600 bps.
Rate at 28.8 K Nxt Disable 28800 24000 19200 16800 14400 12000 9600 7200 4800 2400 1200
Rate at 28.8K. When the modem rate is 28,800 bps the port rate will be as selected by this configuration option (Disable, 28800, or 1200). The total for all ports cannot exceed the modem rate of 28,800 bps.
Rate at 24.0 K Nxt Disable 24000 19200 16800 14400 12000 9600 7200 4800 2400 1200
Rate at 24.0K. When the modem rate is 28,800 bps the port rate will be as selected by this configuration option (Disable, 24000, or 1200). The total for all ports cannot exceed the modem rate of 24,000 bps.
Rate at 19.2 K Nxt Disable 19200 16800 14400 12000 9600 7200 4800 2400 1200
Rate at 19.2K. When the modem rate is 19,200 bps the port rate will be as selected by this configuration option (Disable or 19200 to 1200). The total for all ports cannot exceed the modem rate of 19,200 bps.
Rate at 16.8 K Nxt Disable 16800 14400 12000 9600 7200 4800 2400 1200
Rate at 16.8K. When the modem rate is 16,800 bps the port rate will be as selected by this configuration option (Disable or 16800 to 1200). The total for all ports cannot exceed the modem rate of 16,800 bps.
Rate at 14.4 K Nxt Disable 14400 12000 9600 7200 4800 2400 1200
Rate at 14.4K. When the modem rate is 14,400 bps the port rate will be as selected by this configuration option (Disable or 14400 to 1200). The total for all ports cannot exceed the modem rate of 14,400 bps.
Rate at 12.0 K Nxt Disable 12000 9600 7200 4800 2400 1200
Rate at 12.0K. When the modem rate is 12,000 bps the port rate will be as selected by this configuration option (Disable or 12000 to 1200). The total for all ports cannot exceed the modem rate of 12,000 bps.
Rate at 9600 Nxt Disable 9600 7200 4800 2400 1200
Rate at 9600. When the modem rate is 9600 bps the port rate will be as selected by this configuration option (Disable or 9600 to 1200). The total for all ports cannot exceed the modem rate of 9600 bps.

(4 of 9) DTE Interface Configuration Options — Multiport Mode
Rate at 7200 Nxt Disable 7200 4800 2400 1200
Rate at 7200. When the modem rate is 7200 bps the port rate will be as selected by this configuration option (Disable or 7200 to 1200). The total for all ports cannot exceed the modem rate of 7200 bps.
Rate at 4800 Nxt Disable 4800 2400 1200
Rate at 4800. When the modem rate is 4800 bps the port rate will be as selected by this configuration option (Disable or 4800 to 1200). The total for all ports cannot exceed the modem rate of 4800 bps.
Rate at 2400 End Disable 2400 1200
Rate at 2400. When the modem rate is 2400 bps the port rate will be as selected by this configuration option (Disable or 2400 to 1200). The total for all ports cannot exceed the modem rate of 2400 bps.
Asynchronous/Synchronous Mode. Determines whether the port operates in Asynchronous mode or Synchronous mode.
This configuration option only appears when Async/Sync Mode is configured for Async.
Asynchronous DTE Data Rate. Identifies the asynchronous DTE’s operating rate to the modem. The asynchronous rate must be less than or equal to the synchronous port rate.
=Sync – The asynchronous data is equal to the synchronous rate.
This configuration option only appears when Async/Sync Mode is configured for Async.
Asynchronous Number of Data Bits. Determines if the asynchronous data length is composed of 6, 7, 8, or 9 data bits. This data length excludes start, parity, and stop bits.
This configuration option only appears when Async/Sync Mode is configured for Async.
Asynchronous Number of Stop Bits. Selects 1 or 2 bits to signal the end of an asynchronous character.
DCP Configuration

(5 of 9) DTE Interface Configuration Options — Multiport Mode
This configuration option only appears when Async/Sync Mode is configured for Async.
Asynchronous Overspeed. Provides rate compensation for asynchronous DTEs that may be operating at a slightly higher rate than the asynchronous interface of the port. It accomplishes this by shortening the duration of the stop bit.
1.0 % – Causes the stop bit to be shortened to 87.5% of its original duration.
2.3 % – Causes the stop bit to be shortened to 75% of its original duration.
Data Terminal Ready Action. DTR is a signal from the DTE to the modem indicating that the DTE is connected and ready for operation.
Ignore – Modem assumes DTR is always ON. This is used when the DTE does not provide DTR.
Standard RS232 – Allows the DTE to control DTR to the modem as specified in EIA-232-D and CCITT V.24 specifications. If this signal is not present on at least one port, the modem will not answer or dial.
Controls On-Hook – Required for applications in which the host processor must reset itself for the next session before the current session is terminated. When selected, the modem does not disconnect from the VF line during an active call until DTR is lowered by all DTE ports. This setting is ignored if the modem is commanded to disconnect from its own front panel or by the COMSPHERE 6700 Series Network Management System.
Data Set Ready Control. DSR is a signal from the modem to the DTE indicating the modem is connected and ready for operation.
Standard RS232 – Allows the modem to control DSR to the DTE. The modem raises DSR when it begins the handshake process. DSR lowers upon disconnect. The modem is not ready to receive data until DSR, CTS, and LSD are active. An ON state indicates to the DTE that the modem is ready to receive data. An OFF state indicates that the modem is not ready to receive data, and the DTE will not send data to the modem. During a Local Analog Loop and a Remote Digital Loop, DSR is ON.
Forced On – Forces DSR output ON constantly. This is usually used for leased-line applications and when the DTE requires DSR to always be ON.
Wink When Disconnect – DSR is normally forced ON, but is turned OFF for 1 to 2 seconds upon a disconnect.
Follows DTR – When the modem receives DTR from the DTE, it sends DSR to the DTE.
On Early – DSR is low when the modem is in the idle state. DSR goes high immediately upon a command to enter Data mode. This setting is required for some modem pooling applications.
Delay to Data – Operation is similar to the Standard RS232 except that DSR does not turn ON until the modem enters Data mode. Normally, the modem raises DSR when it begins the handshaking process. Use this setting when the DTE cannot operate with a long DSR-to-CTS delay (common for V.32bis modulation).

(6 of 9) DTE Interface Configuration Options — Multiport Mode
Request-to-Send Action. RTS is a signal from the DTE indicating the DTE has data to send.
Standard RS232 – Allows the DTE to control RTS to the modem in normal EIA-232-D operation. RTS must be ON for the DTE to transmit to the modem.
Ignore – Modem assumes RTS is always ON. Use this selection when the DTE does not provide RTS to the modem.
Simulated Control Carrier – RTS input controls the remote modem’s LSD signal. This is used for DTEs that require Line Signal Detect (LSD) to toggle ON and OFF to simulate half-duplex operation. If RTS Action is set to simulated control carrier, then the remote modem’s LSD Control configuration option must be set to Simulated Control Carrier. Simulated Control Carrier conforms to V.13 specifications. This setting is ignored when the modem is configured for Asynchronous mode and RTS/CTS flow control is selected.
This configuration option only appears when MSD is enabled, or when RTS Action is set to Sim_Cntl_Car.
Request-to-Send Antistreaming. If enabled, the operation of the antistreaming function is as follows. If RTS is ON for a period exceeding the selected time, the modem will take over control of the carrier and will force the carrier OFF. The modem will also force CTS OFF during this time. This condition will stay in effect until the DTE turns RTS OFF. After this, the next time the DTE turns RTS ON, carrier will be turned ON and the RTS timer will start again.
Disable – The antistreaming function is not in effect.
10 sec, 30 sec, 1 min, 2 min, 3 min, 5 min – Enables the antistreaming function and sets the maximum ON time for RTS before antistreaming control takes effect.
Clear-to-Send Control. CTS is a signal from the modem to the DTE indicating that it can accept data from the DTE.
Standard RS232 – In Synchronous mode, forces the state of CTS to follow the state of RTS in normal EIA-232-D operation. The minimum time that elapses between CTS and RTS is determined by the RTS/CTS Delay configuration option. Use this setting for most synchronous applications.
Forced On – CTS is forced ON at all times. Use this selection for most asynchronous applications.
Wink When Disconnect – CTS is normally forced ON, but is turned OFF for 1 to 2 seconds upon a disconnect.
Follows DTR – The state of CTS follows the state of DTR. When DTR turns ON, CTS turns ON. When DTR turns OFF, CTS turns OFF.
Follows RTS – The state of CTS follows the state of RTS. When RTS turns ON, CTS turns ON. When RTS turns OFF, CTS turns OFF.
DCP Configuration

(7 of 9) DTE Interface Configuration Options — Multiport Mode
Request-to-Send/Clear-to-Send Delay. RTS/CTS Delay sets the delay time between the modem receiving RTS from the DTE and the modem sending CTS to the DTE.
raises RTS and the time the modem presents CTS to allow the DTE to send data.
set to Stndrd RS232. If RTS Action is set to Ignore, RTS is always ON and this configuration option has no effect.
Line Signal Detect Control. LSD is a signal indicating that the carrier signal is being received from the remote modem. It is normally turned OFF to the DTE when the power level of the received carrier signal drops below the carrier detect threshold.
Standard RS232 – LSD is ON when the modem detects the remote modem’s carrier signal. LSD turns OFF when the carrier signal strength drops below carrier detect threshold.
Forced On – Forces LSD to be ON at all times.
Wink When Disconnect – LSD is normally forced ON, but can be turned OFF for 1 to 2 seconds upon a disconnect.
Follows DTR – The state of LSD follows the state of DTR. When DTR turns ON, LSD turns ON. When DTR turns OFF, LSD turns OFF.
Simulated Control Carrier – LSD follows the state of RTS of the remote DTE via the V.13 simulated control carrier signaling. This is required for hosts that cannot support full-duplex operation. If LSD Control is set to simulated control carrier, then the RTS Action configuration option on the remote modem must be set to Simulated Control Carrier.
=DTR/Disconnect OFF – The state of LSD follows the state of DTR except when disconnecting once a connection is established. In this instance, DTR remains ON and LSD turns OFF. DTR must then toggle OFF and then ON again for LSD to turn ON. This setting is required for AT&T DATAKIT dial-out applications.
This configuration option only appears when TX Clock Source is configured for Port 1, 2, 3, or 4.
External Transmit Clock Clamps Transmit Clock. Allows the port’s TXC output (Pin 15 on the EIA-232-D interface) to be clamped OFF when TX Clock Source is configured for Port 1, 2, 3, or 4.
Enable – TXC is clamped off when TX Clock Source is configured for Port 1, 2, 3, or 4.
Disable – TXC continues to be provided when TX Clock Source is configured for Port 1, 2, 3, or 4.

(8 of 9) DTE Interface Configuration Options — Multiport Mode
This configuration option does not appear when V.34 is enabled for a leased or dial line.
CT111 Control. Used in conjunction with CT111 Rate Control. (Refer to the Mux Sub-Group section of this table.) Allows the DTE to control modem rate via Pin 23 of the EIA-232-D interface. CT111 is also known as CH on the EIA-232-D interface.
Enable – The DTEs CT111 signal may be used in conjunction with CT111 Rate Control (refer to the Mux Sub-Group section of this table) to control modem rate.
Disable – Disregards the DTEs CT111 signal.
Receive Remote Loopback Response. Determines if the modem responds to a request for a remote loopback issued from a remote modem.
DTE Remote Loopback. Controls the use of Pin 21 of the EIA-232-D/CCITT V.24 interface by the DTE to initiate a remote loopback. An Abort command or test time-out ends this test.
Enable – The DTE forces the modem into remote loopback when the signal on Pin 21 (CCITT 140) is turned ON. Remote Loop ends when the signal is dropped.
Disable – The DTE does not initiate remote loopback in response to the signal on Pin 21.
DTE Local Loopback. Controls the use of Pin 18 of the EIA-232-D/CCITT V.24 interface by the DTE to initiate a local loopback. An Abort command or test time-out ends this test.
Enable – The DTE forces the modem into local loopback when the signal on Pin 18 (CCITT 141) is turned ON. Local loopback ends when the signal is dropped.
Disable – The DTE will not initiate local loopback in response to the signal on Pin 18.
Port Transmit Clock Source. Determines the clock source used to clock transmit data into the port buffer from Pin 2 (TXD) of the EIA-232-D interface. The port buffer is used to compensate for timing differences when a port is connected via a crossover cable to another modem’s EIA-232-D interface.
Internal – The data input to the port buffer (from Pin 2 of the EIA-232-D interface) is clocked into the buffer using the modem’s transmit clock. (The modem’s transmit clock is determined by the TX Clock Source configuration option.) Data is removed from the buffer using this same clock.
External – The data input to the port buffer (from Pin 2 of the EIA-232-D interface) is clocked into the buffer using the clock source provided on Pin 24 (XTXC) of the EIA-232-D interface. Data is removed from the buffer using the modem’s transmit clock. (The modem’s transmit clock is determined by the TX Clock Source configuration option.)
toggling of RTS will prevent the loss of data due to buffer overflow or underflow.
DTE Alarm Mask. Allows you to enable or disable the reporting of DTE alarms (per port) to the front panel and/or NMS.
Enable – No not report alarms.
Disable – Report alarms.
DCP Configuration

(9 of 9) DTE Interface Configuration Options — Multiport Mode
Extend Main Ch.: Disable Nxt Disable Enable
Primary data can only be extended one link.
Extend Main Channel. Supports extended diagnostics. Specifies whether there is main (primary) channel connectivity between the modem’s DTE ports and the DTE ports of modems one level below (downstream) or above (upstream) in the diagnostic network.
Enable – If this configuration option is set to Enable on a port of a tributary modem, test mode is propagated to the modems downstream when test mode goes ON for that port.
Disable – If this configuration option is set to Disable on a port of a tributary modem, test mode is not propagated for that port and primary channel data is clamped when in test mode.
the main (primary) channel is extended.
to the Extended Point-to-Point section in Appendix G.
This configuration only appears when the Extended Main Channel is enabled.
Upstream Port. When an extended control modem’s main (primary) channel is connected to a tributary modem that is one link above it in the diagnostic network, this configuration option is set to the port number to which it is connected on the tributary modem.

Line Dialer — Multiport Mode
The Line Dialer configuration options establish parameters used by the modem to answer or originate calls.
Table 4-2 shows each Line Dialer configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 3) Line Dialer Configuration Options — Multiport Mode
Auto-Answer Ring Count. Determines the number of rings necessary before the answering modem answers an incoming call. For example, if this option is set to 2, then the answering modem answers after the second ring.
Disable – If selected, the modem must be answered using either the DCP’s Answer command or the Talk/Data function. Refer to Talk/Data in Chapter 3, DCP Operation, for more on Manual Answer.
Dialer Type. Selects either tone (DTMF) dialing or pulse (rotary) dialing mode.
Dial Tone Detect. Sets the modem for dial tone detection (enable) or blind dialing (disable).
Enable – Modem disconnects the call if a dial tone is not detected within 10 seconds and displays No Dial Tone on both the LCD and asynchronous DTE terminal.
Disable – Modem dials a call whether or not it detects a dial tone on the line. This is known as blind dialing. The period of time the modem waits before dialing is specified in the Blind Dial Paus configuration option.
This configuration option only appears when Dial Tone Detect is disabled.
Blind Dial Pause. Determines how long the modem waits before dialing a telephone number when Dialtone Detect is disabled.
Busy Tone Detect. Sets the modem to monitor for Busy Tone (Enable) or ignore Busy Tone (Disable).
configuration option can be disabled and the modem ignores all busy tones.
DCP Configuration

(2 of 3) Line Dialer Configuration Options — Multiport Mode
Pause Time. Determines the number of seconds the modem pauses when it encounters a comma (,) in the dial command string.
No Answer Abort Time-out. Determines the number of seconds an originating modem waits before abandoning a call attempt when no answer tone is received.
Fast Disconnect. Allows the modem to disconnect immediately after receiving a disconnect command from a local DTE or its own diagnostic control panel.
Disable – The modem follows its normal disconnect sequence by issuing a cleardown sequence or long space disconnect. This is also known as a graceful disconnect since the other modem receives advance notice of a disconnection.
Enable – Use this setting if the DTE requires that the modem be made available as soon as possible after receiving a disconnect command.
disconnection as an error instead of a valid disconnect.
This configuration option does not appear on Models 3920-A1-401 and 3921-B1-001.
Line Current Disconnect. Determines the modem’s response to short interruptions of line current. The loss of line current is one method of disconnecting a call.
Enable > 8-millisecond – Disconnects the modems if line current is disrupted for more than 8 milliseconds.
Enable > 90-millisecond – Disconnects the modems if line current is disrupted for more than 90-milliseconds. Use this setting if the modem constantly disconnects when set to Enab(>8msec).
Disable – Ignores any disruptions in line current such as call waiting.
Long Space Disconnect. Determines the modem’s response to a continuous spacing condition sent from the remote modem before it goes on-hook. Issuing a long space is one method of disconnecting a call.
Enable – Modem disconnects if it receives a continuous space from the DTE. For modulations lower than 4800 bps the modem’s transmitter will transmit 4 seconds of long space upon a disconnect.
Disable – Modem does not disconnect if it receives a continuous space from the DTE. Modem will not transmit a long space disconnect.

(3 of 3) Line Dialer Configuration Options — Multiport Mode
No Carrier Disconnect. If the modem no longer receives carrier from the remote modem, it disconnects the call. This configuration option determines how long carrier is OFF before the modem disconnects. Loss of carrier is one method of disconnecting a call.
2, 5, 10, 20 sec – Modem disconnects if carrier turns OFF for more than 2 seconds, 5 seconds, 10 seconds, or 20 seconds.
Disable – Modem does not disconnect if carrier turns OFF.
No Data Disconnect. Forces the modem to disconnect if no data is transmitted and received within a specified amount of time.
Disable – Modem remains connected despite the lack of data flow.
10, 30, 60 min – Modem disconnects if data is not received and transmitted within 10-minute, 30-minute, or 60-minute intervals.
This option is only valid on Model 3921Plus.
Automatic Make Busy. Forces the modem to go off-hook under the following conditions: if a local analog loopback is performed, a self-test is performed, or if the modem is switched to the service line.
Exchange (PBX). The Make Busy Network Interface Module (NIM) must be installed on the COMSPHERE 3000 Series Carrier. Refer to the COMSPHERE 3000 Series Carrier, Installation Manual.
DCP Configuration

Dial Line — Multiport Mode
The Dial Line configuration options are used to configure the modem for operation over dial lines.
Table 4-3 shows each Dial Line configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 2) Dial Line Configuration Options — Multiport Mode
Dial Modulation. Modulation reduces the amount of scrolling necessary to select Dial Line rates by limiting the number of Dial Line Rate configuration options. Only one group of Dial Line rates is displayed depending on the setting of the Dial Modulation configuration option (V.34, V.32bis, and V.32 terbo).
Dial Line Rate: 28800(V34) Nxt 33600 28800(V34) 24000(V34) 19200(V34) 16800(V34) 14400(V34) 12000(V34) 9600(V34) 7200(V34) 4800(V34) 2400(V34) 19200(V32t) 16800(V32t) 14400(V32b) 12000(V32b) 9600(V32b) 7200(V32b) 4800(V32b)
Dial Line Rate. This configuration option determines the modem’s data rate and modulation scheme for operation on dial lines. Online changes do not take effect until a disconnect occurs.
33600, 28800(V34), 24000(V34), 19200(V34), 16800(V34), 14400(V34), 12000(V34), 9600(V34), 7200(V34), 4800(V34), 2400(V34) – The modem operates using V.34 modulation at the data rate selected.
19200(V32t), 16800(V32t), 14400(V32b), 12000(V32b), 9600(V32b), 7200(V32b), 4800(V32b) – The modem operates using V.32bis or V.32 terbo modulation at the data rate selected.
Autorate. Once connected, the modem automatically lowers the line rate if line conditions become impaired. When line conditions improve, the modem automatically shifts up to the highest data rate the line can support. This autorating only occurs between 19,200 bps and 4800 bps during V.32, V.32bis, and V.32 terbo connections, and 33.6 to 2400 for V.34.
Start at 48 and Start at 96 – Set the maximum connect rate for V.32, V.32bis, and V.32 terbo connections.
This configuration option is ignored unless Dial Line Rate is 4800(V32b).
V.32bis Override. Activates the Paradyne Point-to-Point Diagnostic 2400 bps modulation. Allows the modem to use a non-standard, point-to-point modulation capable of secondary channel diagnostics while running at 2400 bps.

(2 of 2) Dial Line Configuration Options — Multiport Mode
Dial Tx Level: Permissv(–9) Nxt Permissv(–9) –10 –11 –12 –13 –14 –15 –16 –17 –18 –19 –20 –21 –22 –23 –24 –25 –26 –27 –28 –29 –30 –31 –32
Dial Transmit Level. Selects the modem’s transmit power level over dial lines. The transmit output level can be selected in 1 dBm decrements from –9 dBm to –32 dBm.
configuration option is locked in other countries (the user cannot change the level).
Train Time. Controls V.34 and V.32 family train time. Determines whether minimum or maximum time durations are used during the handshaking sequence for both dial and 4-wire/2-wire leased-line applications.
Long – Selects long train. Use this setting whenever far-end frequency offset (phase roll) may be encountered. This is usually only required when transmitting over satellite links.
Short – Allows the modem to train-up faster when using V.32 terbo, V.32bis, or V.32 modulation.
This configuration option does not appear unless V.34 is enabled.
Asymmetric Rate. Controls rate symmetry when running V.34 modulation by enabling or disabling the V.34 modulation from using equal transmit and receive rates.
Enable – The modem operates in asymmetric rate mode (the transmit and receive rates can be different) when running V.34 modulation. The Asymmetric Rate configuration option must be enabled in both modems.
Disable – The modem operates in symmetric rate mode (the transmit and receive rates are identical) when running V.34 modulation. Either modem can force symmetric mode by disabling the Asymmetric Rate configuration option.
DCP Configuration

Leased Line — Multiport Mode
The Leased Line configuration options only appear when the Sync Leased factory preset template is selected. They are used to configure the modem for operation over leased lines.
Table 4-4 shows each Leased Line configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 3) Leased Line Configuration Options — Multiport Mode
Lease Modulation. Modulation reduces the amount of scrolling necessary to select Leased Line rates by limiting the number of Leased Line Rate configuration options. Only one group of Leased Line rates is displayed depending on the setting of the Lease Modulation configuration option (V.34, V.32bis, V.32 terbo, and TMp).
LeasedLine Rate: 28800(V34) Nxt 33600 28800(V34) 24000(V34) 19200(V34) 16800(V34) 14400(V34) 12000(V34) 9600(V34) 7200(V34) 4800(V34) 2400(V34) 19200(V32t) 16800(V32t) 14400(V32b) 12000(V32b) 9600(V32b) 7200(V32b) 4800(V32b) 19200(TMp) 14400(TMp) 9600(TMp) 7200(TMp) 4800(TMp) 2400(TMp)
Leased-Line Rate. Determines the modem’s data rate and modulation scheme for operation on leased lines. These modulation schemes are available on 2-wire or 4-wire lease.
33600, 28800(V.34), 24000(V34), 19200(V34), 16800(V34), 14400(V34), 12000(V34), 9600(V34), 7200(V34), 4800(V34), 2400(V34) – The modem operates using V.34 modulation at the data rate selected.
19200(V32t), 16800(V32t), 14400(V32b), 12000(V32b), 9600(V32b), 7200(V32b), 4800(V32b) – The modem operates using V.32bis or V.32 terbo modulation at the data rate selected.
19200(TMp), 14400(TMp), 9600(TMp), 7200(TMp), 4800(TMp), 2400(TMp) – The modem operates in Trellis Multipoint mode at the data rate selected. These modulation schemes are available on 4-wire leased lines. The 19200(TMp) modulation does not appear on tributary modems.
Leased Mode. Sets the modem for either 2-wire or 4-wire operation in Answer mode (receiving a call) or 2-wire or 4-wire operation in Originate (initiating a call) mode.
and the other set to Answer mode.
For Sync Leased Originate Mode, Async Leased Originate Mode and Trellis Multipoint Control Mode, 4-wire Originate is the factory default.
Autorate. Once connected, the modem automatically lowers the line rate if line conditions become impaired. When line conditions improve, the modem automatically shifts up to the highest data rate the line can support. This autorating only occurs between 19,200 bps and 4800 bps during V.32, V.32bis, V.32 terbo connections, and 33.6 to 2400 for V.34.

(2 of 3) Leased Line Configuration Options — Multiport Mode
This configuration option is ignored unless Leased-Line Rate is 4800(V32b).
V.32bis Override. Activates the Paradyne Point-to-Point Diagnostic 2400 bps modulation. Allows the modem to use a non-standard, point-to-point modulation capable of secondary channel diagnostics while running at 2400 bps.
Leased Tx Level: 0 Nxt 0 –1 –2 –3 –4 –5 –6 –7 –8 –9 –10 –11 –12 –13 –14 –15
Leased Transmit Level. Selects the modem’s transmit power level over leased-lines. The transmit output level can be selected in 1 dBm decrements from 0 dBm to –15 dBm.
The AT command is S-Register S45=n, where n is from 0 to 15 corresponding to 0 dBm to –15 dBm.
This configuration option does not appear unless V.34 is enabled.
Asymmetric Rate. Controls rate symmetry when running V.34 modulation by enabling or disabling the V.34 modulation from using equal transmit and receive rates.
Enable – The modem operates in asymmetric rate mode (the transmit and receive rates can be different) when running V.34 modulation. The Asymmetric Rate configuration option must be enabled in both modems.
Disable – The modem operates in symmetric rate mode (the transmit and receive rates are identical) when running V.34 modulation. Either modem can force symmetric mode by disabling the Asymmetric Rate configuration option.
Automatic Dial Backup. Allows the modem to dial the number stored in directory location 1 to restore communications with the remote modem when the leased lines fail.
modem. The answering modem must have its Auto-Answer Ring Number configuration option enabled. Refer to the Line Dialer configuration option group for information regarding Auto-Answer.
10 call attempts, with a 2 minute delay between calls. This function can only be reset with a completed manual dial backup, a power cycle, or using NMS.
Fast Backup – Only used in special applications requiring a shortened delay time from the failure of the leased lines to the initiation of the automatic dial backup.
AutoDialStandby: Disable Nxt Disable 15min 1hr 4hr Test(2min) Adv 15min Adv 30min Adv 1 hr TestAdv2min
Automatic Dial Standby. Permits a modem operating on dial lines (regardless of the method of dialing origination) to check the quality of the leased lines periodically and, if they are good, to disconnect from the dial lines and resume operations on the leased lines. The time interval that the modem uses to check the quality of the leased lines is determined by the configuration option. These intervals are 15 minutes, 1 hour, and 4 hours. The Test(2min) and TestAdv2min selections are for testing purposes only. The Adv 15min, Adv 30min, and Adv 1 hr selections cause the modem to evaluate the leased lines continuously in a manner which is non-disruptive to the dial-line communication.
DCP Configuration

(3 of 3) Leased Line Configuration Options — Multiport Mode
This configuration option is only available if Automatic Dial Standby is configured for 15min, 1hr, 4hr or Test(2min) and Leased mode is configured for Originate mode, or if Automatic Dial Standby is configured for Adv15min, Adv30min, Adv1hr or TestAdv(2min).
Special Standby. Used to support Automatic Dial Standby configurations when a third modem is used for the dial backup. When the leased line is restored, the Special Standby configuration allows the leased-line modems to return service to the original point-to-point modems.
configuration option allows the originate modem to test the lease connection in one direction before interrupting primary data on the dial lines.
Special Standby configuration option allows a non-interruptive algorithm to test the original point-to-point lease connection in both directions before interrupting primary data on the dial lines.
Dial Standby Time. Selects the amount of time that a dial circuit is held after returning to the leased lines.
Carrier On Level. Controls the carrier detection threshold for leased lines. When the power level of the receive carrier signal drops 2 dBm below this level (either –26 dBm or –43 dBm), LSD turns OFF. When the carrier signal is greater than this level, LSD turns ON.
Lease Lookback. While operating on backup lines, this configuration option allows the modem to test the primary 4-wire leased lines for connectivity by detecting line energy across the normal line bandwidth. This test of the primary lines will not interrupt the data flow on the backup lines. The configuration option settings must be the same at both ends.
Dual Leased Line. Allows the 2-wire backup facility to function as a 2-wire leased line facility. When this configuration option is disabled, the backup facility is a 2-wire dial line.
Except for dialing, ring indication, and call progression functions, you control the backup function as if it were a normal dial backup.
This configuration option only appears when Dual Leased Line is enabled.
This configuration option does not appear when V.34 is enabled.
Backup Line Check. Tests the backup circuit for availability while the modem is operating on the primary 4-wire leased lines. The test involves detecting line energy across the normal bandwidth. This test of the backup lines will not interrupt the data flow on the primary lines. The configuration option settings must be the same at both ends.
modem connected to the primary leased-line, enabling this configuration can cause problems.

Test — Multiport
The Test configuration option determines the duration of a test.
Table 4-5 shows the Test configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
Table 4-5 Test Configuration Options — Multiport Mode
Test Time-out. Determines how long a test runs before aborting.
Disable – Allows a test to run indefinitely.
30, 60, or 240 seconds – Allows the test to run for 30 seconds, 60 seconds, or 240 seconds.
V.54 Address. Determines which remote 392xPlus modem is placed into a remote loopback test. This test can be either a remote digital loopback or local analog loopback. This type of addressing should be used for extended data circuits (tail circuits).
Disable – This is used for normal point-to-point leased-line and dial networks.
Address Values – 01, 03, 05, 07, 09, 0B, 0D, 0F, 11, 13, 15, 17, 19, 1B, 1D, 1F, 25, 27, 2B, 2D, 2F, 33, 35, 37, 3B, 3D, 3F, 55, 57, 5B, 5F, 6F, 77, or 7F. This configuration option selects the address of a modem that is to be placed into a loopback test. This configuration option is used for more complex networks where multiple modems, used in extended data circuits (tail circuits), can be commanded to loopback.
The AT command for Disable is S-Register S53=0. The AT command for V.54 Address is S-Register S53=n, where n is a value from 1 to 34.
This configuration option only appears when V54 Address is enabled.
V.54 Device Type. Identifies where the modem is physically located in the network.
Peripheral – The modem is located at the endpoint of the network and is not connected back-to-back with another modem.
Intermediate – The modem is either of the two modems connected back-to-back.
The AT command for Peripheral is S-Register S54=0. The AT command for Intermediate is S-Register S54=1.
DCP Configuration

Misc — Multiport
The Miscellaneous configuration options determine specifics for various functions, including network management parameters and remote modem access.
Table 4-6 shows each Misc (Miscellaneous) configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 3) Miscellaneous Configuration Options — Multiport Mode
Straps When Disconnected. Determines whether or not configuration options in the Active (Saved) configuration area are reloaded to Active (Operating) when a disconnect occurs. This is appropriate in Async Dial Mode only.
No Change – Configuration options do not change if a disconnect occurs.
Reload – The Active (Operating) configuration area, which controls modem operation, is reloaded from the Active (Saved) configuration area when a disconnect occurs. This is useful in modem pooling applications where it is desirable to start the modem from a known condition after every call.
Speaker Control. Determines if the speaker is OFF, ON until carrier signal is received by the modem, or ON all the time.
restore the modem to the Speaker Control and Speaker Volume configuration option settings.
Speaker Volume. Controls the level of speaker volume.
restore the modem to the Speaker Control and Speaker Volume configuration option settings.
Access from Remote. Determines if your modem’s DCP can be accessed by a remote modem via the VF line.
Enable – Allows access from a remote modem.
Disable – Does not allow access from a remote modem.
Remote Access Password. Allows the entry of a password for establishing control of a remote modem from the DCP of a local modem. The same password must be used in both the local and remote modem.

(2 of 3) Miscellaneous Configuration Options — Multiport Mode
Directory Location 1 Callback. This configuration option controls whether or not the modem’s single number callback function is used.
Disable – Modem does not use the single number callback function.
Enable – Modem answers a call, disconnects, and dials the number stored in directory location 1.
NMS Call Messages. Determines if the modem status and/or call summary information is sent to the NMS. The modem can itemize status, such as CallProgress messages, or it can report a summary of activity, such as Call Connect messages, to the NMS.
Call Connect & Progress – Enables both Call Connect and Call Progress information to be transmitted to the NMS.
Disable – Modem status and call summary information is not sent to the NMS.
Call Connect Only – The modem accumulates call statistics over a period of time and then transmits a summary of these statistics to the NMS. The NMS uses this data to produce utilization reports.
Call Progress Only – The modem transmits detailed modem status information to the NMS. These messages include any events that can display on the LCD.
Network Position Identification. Each modem must be identified either as a control modem or a tributary modem.
For the Model 3920Plus, Tributary is the factory default. For the Model 3921Plus, Control is the factory default.
This configuration option is not available in point-to-point tributaries, which are always set to address 01.
Network Management Address. Determines the address used when accessing a modem from the NMS or when using DCP functions that require network management addresses. Within a network link, a control modem can communicate with a tributary modem by using the tributary modem’s network management address. Each TMp tributary modem must have a different network management address. Address values range from 001 to 256.
DCP Configuration

(3 of 3) Miscellaneous Configuration Options — Multiport Mode
This configuration option does not appear when the LeaseLine Rate is configured for TMp and NetworkPosition is configured for Tributary.
Diagnostic Connection. Allows the configuration of the serial diagnostic port of the modem to be either a diagnostic channel that is connected to another modem (DC), or a control channel that is connected to a network management device (CC).
Modem (DC) – Selects the Diagnostic Channel.
NMS(CC) – Selects the Control Channel.
Disable – Prevents messages being sent from the diagnostic port.
Link Delay Seconds. Controls the length of time (in seconds) a modem will wait for responses from the downstream devices. This configuration option is used to calculate protocol timers for polling and normal selection.

In Singleport mode, the modem’s configuration options are arranged into nine groups based on functionality:
The following graphic represents the structure of the configuration options in Singleport mode.
DCP Configuration

AutoAnswerRing# Dialer Type DialTone Detect Blind Dial Paus BusyTone Detect "," Pause Time NoAnswer Timout Fast Disconnect Line Crnt Disc Long Space Disc No Carrier Disc No Data Disc Auto Make Busy MakeBusyVia DTR
LeaseModulation LeasedLine Rate Leased Mode Autorate V32bis Override Leased Tx Level Asymmetric Rate Auto Dial Back AutoDialStandby SpecialStandby DialStandbyTime CarrierOn Level V27bis Train V29 TrainOnData V29 Retrain V29 Link Config TMp Train Time TMp TxPreemphis Lease Lookback Dual_Leased_Ln BackupLine Check
DTE RL(CT140) DTE LL(CT141) Test Timeout Rcv Remote Loop V54 Address V54 Device Type
Port 1* MUX* MUX Mode
Async/Sync Mode Async DTE Rate Asyn #Data Bits Asyn Parity Bit Asyn #Stop Bits DTR Action DSR Control RTS Action RTS Antistream CTS Control RTS/CTS Delay LSD Control Tx Clock Source Bakup_TXClk_Src XTXC Clamps TXC CT111_Rate Cntl DTE_Rate=VF Extend Main Ch. Upstream Port
V.42/ MNP/Buffer
DTE Dialer Type AT Escape Char Escape GuardTim BreakForceEscap CommandCharEcho CarriageRtn Char Backspace Char Linefeed Char Result Codes ExtendResltCode ResultCode Form AT Cmnd Mode V25bis Coding V25bis IdleFill V25b NewLineChr
Dial Modulation Dial Line Rate Automode Autorate V32bis Override Dial Tx Level V22b Guard Tone Train Time Asymmetric Rate
Err Contrl Mode V42bis Compress MNP5 Compress EC Negotiat Bfr EC Fallbck Char Flw Cntl of DTE Flw Cntl of Mdm XON/XOFF Psthru Mdm/Mdm FlowCtl Break Buffr Ctl Send Break Cntl BuffrDiscDelay Max Frame Size CellularEnhance RdcdAsyncBufSiz
StrapsWhenDisc Speaker Control Speaker Volume Access frm Remt RemAccssPasswrd Dir#1_Callback NMS_Call_Msgs NetworkPosition NetMngmtAddress Diag Connection Link Delay(sec)
*Does not appear on Singleport modems.

DTE Interface — Singleport Mode
The DTE Interface configuration options contain EIA-232-D (CCITT V.24) and asynchronous character format information essential for maintaining a connection and for transmitting data between the DTE and the modem.
Table 4-7 shows each DTE Interface configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 8) DTE Interface Configuration Options — Singleport Mode
Asynchronous/Synchronous Mode. Determines whether the modem operates in Asynchronous mode or Synchronous mode. If the AT command set is enabled and this configuration option is set to Sync, then the modem operates in Async mode when offline.
For Async Dial, Async Leased and UNIX Dial, Async is the factory default.
The AT commands for Async Mode are &M0 or &Q0. The AT commands for Sync Mode are &M1, &M2, &M3, or &Q1, &Q2, &Q3.
This configuration option only appears when Async/Sync Mode is configured for Async.
Asynchronous DTE Data Rate. Identifies the asynchronous DTE’s operating rate to the modem. Data rates from 57,600 bps to 300 bps are supported.
a communications package which can take advantage of its 16-byte buffer. In addition, a 386 PC (25 MHz or faster) is required, and the RS232 cable length must be minimized to reduce capacitance.
configuration option (see the V.42/MNP/Buffer — Singleport Mode section) is set to BufferMode.
The AT prefix determines Async DTE Rate.
DCP Configuration

(2 of 8) DTE Interface Configuration Options — Singleport Mode
This configuration option only appears when Async/Sync Mode is configured for Async.
Asynchronous Number of Data Bits. Determines if the asynchronous data length is composed of 6, 7, 8, or 9 data bits. This data length excludes start, parity, and stop bits.
9(DirectMode) – Sets data length to 9 data bits. Only valid when Error Control configuration option is set to Direct Mode.
6(DirectMode) – Sets data length to 6 data bits. Only valid when Error Control configuration option is set to Direct Mode.
equal 10 bits. Total character size consists of start, data, parity, and stop bits. V.25bis Async must use 7 data bits with even parity and 1 stop bit. The total character size for Error Control mode, Direct mode, or Buffer mode must be 11 bits or less.
The AT prefix determines the async character length.
This configuration option only appears when Async/Sync Mode is configured for Async.
Asynchronous Parity Bit. Determines the type of asynchronous parity bit. The parity of the DTE must match the parity of the modem. Parity options include None, Even, Odd, Mark, or Space.
None – No parity bit is used.
Even – Parity bit is set so that total number of 1’s in data bits plus parity bit is even.
Odd – Parity bit is set so that total number of 1’s in data bits plus parity bit is odd.
Mark – Parity bit is always set to 1. Only valid if Async #Data Bits configuration option is set to 7.
Space – Parity bit is always set to 0. Only valid if Async #Data Bits configuration option is set to 7.
equal 10 bits. Total character size consists of start, data, parity, and stop bits. V.25bis Async must use 7 data bits with even parity and 1 stop bit. The total character size for Error Control mode, Direct mode, or Buffer mode must be 11 bits or less.
The AT prefix determines parity of the async character.
This configuration option only appears when Async/Sync Mode is configured for Async.
Asynchronous Number of Stop Bits. Selects 1 or 2 bits to signal the end of an asynchronous character.
equal 10 bits. Total character size consists of start, data, parity, and stop bits. V.25bis Async must use 7 data bits with even parity and 1 stop bit. The total character size for Error Control mode, Direct mode, or Buffer mode must be 11 bits or less.
The AT prefix determines the number of stop bits via autobauding.

(3 of 8) DTE Interface Configuration Options — Singleport Mode
Data Terminal Ready Action. DTR is a signal from the DTE to the modem indicating that the DTE is connected and ready for operation.
Ignore – Modem assumes DTR is always ON. This is used when the DTE does not provide DTR.
Standard RS232 – Allows the DTE to control DTR to the modem as specified in EIA-232-D and CCITT V.24 specifications. If this signal is not present, the modem will not answer or dial.
Controls On-Hook – Required for applications in which the host processor must reset itself for the next session before the current session is terminated. When selected, the modem does not disconnect from the VF line during an active call until DTR is lowered by the attached DTE. This setting is ignored if the modem is commanded to disconnect from its own front panel or by the COMSPHERE 6700 Series Network Management System.
Controls Transmitter Mute – Mutes the transmitter whenever DTR drops on the DTE interface. This selection is valid only in the V32bis modulation and can be used on the answer side modem to force the originate modem to initiate a dial backup.
DTR to dial or answer a call.
Ready). If DTE Dialer Type configuration option is set to DTR=Direct 1, then DTR Action behaves as CT108/1 (Connect Data Set to Line).
The AT command for Ignore is &D0. The AT commands for Standard RS232 are &D1, &D2 or &D3. The AT command for CntrlsOnHook is &D4. The AT command for CntrlsTxMute is &D5.
Data Set Ready Control. DSR is a signal from the modem to the DTE indicating the modem is connected and ready for operation.
Standard RS232 – Allows the modem to control DSR to the DTE. The modem raises DSR when it begins the handshake process. DSR lowers upon disconnect. The modem is not ready to receive data until DSR, CTS, and LSD are active. An ON state indicates to the DTE that the modem is ready to receive data. An OFF state indicates that the modem is not ready to receive data, and the DTE will not send data to the modem. During a Local Analog Loop and a Remote Digital Loop, DSR is ON.
Forced On – Forces DSR output ON constantly. This is usually used for leased-line applications and when the DTE requires DSR to always be ON.
Wink When Disconnect – DSR is normally forced ON, but is turned OFF for 1 to 2 seconds upon a disconnect.
Follows DTR – When the modem receives DTR from the DTE, it sends DSR to the DTE.
On Early – DSR is low when the modem is in the idle state. DSR goes high immediately upon a command to enter Data mode. This setting is required for some modem pooling applications.
Delay to Data – Operation is similar to the Standard RS232 except that DSR does not turn ON until the modem enters Data mode. Normally, the modem raises DSR when it begins the handshaking process. Use this setting when the DTE cannot operate with a long DSR-to-CTS delay (common for V.32bis modulation) or when dial access security is enabled and requires a DTE-side password entry. Often, the DTE cannot accept the long delay between DSR and CTS turning ON due to the remote user entering the DTE-side password.
DCP Configuration

(4 of 8) DTE Interface Configuration Options — Singleport Mode
The AT command for Forced On is &S0. The AT command for Standard RS232 is &S1. The AT command for Wink When Disconnect is &S2. The AT command for Follows DTR is &S3. The AT command for On Early is &S4. The AT command for Delay to Data is &S5.
Request-to-Send Action. RTS is a signal from the DTE indicating the DTE has data to send.
Standard RS232 – Allows the DTE to control RTS to the modem in normal EIA-232-D operation. RTS must be ON for the DTE to transmit to the modem.
Ignore – Modem assumes RTS is always ON. Use this selection when the DTE does not provide RTS to the modem.
Simulated Control Carrier – RTS input controls the remote modem’s LSD signal. This is used for DTEs that require Line Signal Detect (LSD) to toggle ON and OFF to simulate half-duplex operation. If RTS Action is set to simulated control carrier, then the remote modem’s LSD Control configuration option must be set to Simulated Control Carrier. Simulated Control Carrier conforms to V.13 specifications. This setting is ignored when the modem is configured for Asynchronous mode and RTS/CTS flow control is selected.
Control Carrier – Allows the DTE’s RTS signal to control the modem’s carrier signal. When RTS is ON, carrier is present on the VF line. When RTS turns OFF, carrier is not present. This is only valid for V.29 and V.27bis leased-line modulations. Auto Dial Backup is always disabled for this setting.
The AT command for Standard RS232 is &R0. The AT command for Ignore is &R1. The AT command for Simulated Control Carrier is &R2. The AT command for Control Carrier is &R3.
This configuration option only appears in TMp Tributary mode, or when RTS_Action is configured for Cntl_Car (V.29 and V.27bis).
Request-to-Send Antistreaming. If enabled, the operation of the antistreaming function is as follows. If RTS is ON for a period exceeding the selected time, the modem will take over control of the carrier and will force the carrier OFF. The modem will also force CTS OFF during this time. This condition will stay in effect until the DTE turns RTS OFF. After this, the next time the DTE turns RTS ON, carrier will be turned ON and the RTS timer will start again.
Disable – The antistreaming function is not in effect.
10 sec, 30 sec, 1 min, 2 min, 3 min, 5 min – Enables the antistreaming function and sets the maximum ON time for RTS before antistreaming control takes effect.
The AT command is S-Register S72=n, where n is 0 for Disable, 1 for 10 sec, 2 for 30 sec, 3 for 1 min, 4 for 2 min, 5 for 3 min, and 6 for 5 min.

(5 of 8) DTE Interface Configuration Options — Singleport Mode
Clear-to-Send Control. CTS is a signal from the modem to the DTE indicating that it can accept data from the DTE.
Standard RS232 – In Synchronous mode, forces the state of CTS to follow the state of RTS in normal EIA-232-D operation. The minimum time that elapses between CTS and RTS is determined by the RTS/CTS Delay configuration option. Use this setting for most synchronous applications. In AT Command mode, CTS goes low just prior to DSR going active and goes high when the modem enters Data mode. This operation prevents losing data in applications which begin transmitting as soon as DSR and CTS are both active.
Forced On – CTS is forced ON at all times. Use this selection for most asynchronous applications.
Wink When Disconnect – CTS is normally forced ON, but is turned OFF for 1 to 2 seconds upon a disconnect. Use this for most UNIX applications.
Follows DTR – The state of CTS follows the state of DTR. When DTR turns ON, CTS turns ON. When DTR turns OFF, CTS turns OFF.
Follows RTS – The state of CTS follows the state of RTS. When RTS turns ON, CTS turns ON. When RTS turns OFF, CTS turns OFF.
of CTS Control.
The AT command for Forced On is \D0. The AT command for Standard RS232 is \D1. The AT command for Wink When Disconnect is \D2. The AT command for Follows DTR is \D3. The AT command for Follows RTS is \D4.
Request-to-Send/Clear-to-Send Delay. RTS/CTS Delay sets the delay time between the modem receiving RTS from the DTE and the modem sending CTS to the DTE.
delay between the time the DTE raises RTS and the time the modem presents CTS to allow the DTE to send data.
set to Stndrd RS232. If RTS Action is set to Ignore, RTS is always ON and this configuration option has no effect.
The AT command is S-Register S26=n, where n is a value from 0 to 255 in 10 millisecond increments.
DCP Configuration

(6 of 8) DTE Interface Configuration Options — Singleport Mode
Line Signal Detect Control. LSD is a signal indicating that the carrier signal is being received from the remote modem. It is normally turned OFF to the DTE when the power level of the received carrier signal drops below the carrier detect threshold.
Standard RS232 – LSD is ON when the modem detects the remote modem’s carrier signal. LSD turns OFF when the carrier signal strength drops below carrier detect threshold.
Forced On – Forces LSD to be ON at all times.
Wink When Disconnect – LSD is normally forced ON, but can be turned OFF for 1 to 2 seconds upon a disconnect. This is used for UNIX DTEs.
Follows DTR – The state of LSD follows the state of DTR. When DTR turns ON, LSD turns ON. When DTR turns OFF, LSD turns OFF.
Simulated Control Carrier – LSD follows the state of RTS of the remote DTE via the V.13 simulated control carrier signaling. This is required for hosts that cannot support full-duplex operation. If LSD Control is set to simulated control carrier, then the RTS Action configuration option on the remote modem must be set to Simulated Control Carrier.
=DTR/Disconnect OFF – The state of LSD follows the state of DTR except when disconnecting once a connection is established. In this instance, DTR remains ON and LSD turns OFF. DTR must then toggle OFF and then ON again for LSD to turn ON. This setting is required for AT&T DATAKIT dial-out applications.
The AT command for Forced On is &C0. The AT command for Standard RS232 is &C1. The AT command for Wink When Disconnect is &C2. The AT command for Follows DTR is &C3. The AT command for Simulated Control Carrier is &C4. The AT command for =DTR/Disconnect OFF is &C5.
This configuration option only appears when Async/Sync Mode is configured for Sync.
Transmit Clock Source. Determines the source of timing for synchronous data transmitted from the modem to the analog channel.
Internal – The transmit data’s clock source is derived from the modem’s internal clock. This clock is available as an output on Pin 15 (TXC) of the EIA-232-D interface.
External – The transmit data’s clock source is provided by the DTE on Pin 24 (XTXC) on the EIA-232-D interface.
Receive Clock Loop – The modem’s transmit clock is derived from its received analog signal. The derived clock is available as an output on Pin 15 (TXC) of the EIA-232-D interface.
The AT command for Internal is &X0. The AT command for External is &X1. The AT command for RXC Loop is &X2.

(7 of 8) DTE Interface Configuration Options — Singleport Mode
This configuration option only appears in customized installations in which the Dual_Leased_Ln is configured for Enable and Async/Sync Mode is Sync.
Backup Transmit Clock Source. Selects the clock reference source when operating in the Dual Leased Line Mode. This is a special mode in which one leased line is used to back up another.
Internal – The transmit data’s clock source is derived from the modem’s internal clock. This clock is available as an output on Pin 15 (TXC) of the EIA-232-D interface.
External – The transmit data’s clock source is provided by the DTE on Pin 24 (XTXC) on the EIA-232-D interface.
Receive Clock Loop – The modem’s transmit clock is derived from its received analog signal. The derived clock is available as an output on Pin 15 (TXC) of the EIA-232-D interface.
This configuration option only appears when TX Clock Source is configured for External.
External Transmit Clock Clamps Transmit Clock. Allows the modem’s TXC output (Pin 15 on the EIA-232-D interface) to be clamped OFF when TX Clock Source is configured for External.
Enable – TXC is clamped off when TX Clock Source is configured for External.
Disable – TXC continues to be provided when TX Clock Source is configured for External.
The AT command is S-Register S71=n, where n is 0 for Enable and 1 for Disable.
This configuration option does not appear when V.34 is enabled for a leased or dial line.
CT111 Rate Control. Allows the DTE to control modem rate via Pin 23 of the EIA-232-D interface. This configuration option determines the effect of the DTE Rate control signal. CT111 is also known as CH on the EIA-232-D interface.
Disable – Disregards CT111 Rate Control.
Fallback1 – Forces the modem to decrease its configured data rate to the next lower data rate when CT111 is OFF. Valid only for V.32bis, V.33, V.29 modulation. Modem will only fall back within the same modulation scheme. When CT111 turns ON, the modem returns to its previous data rate.
Fallback2 (Not available for TMp tributaries) – Forces the modem to decrease two data rates while remaining in the same modulation scheme. When CT111 turns ON, the modem returns to its previous data rate.
disable the V.32bis Autorate and V.32bis Automode configuration options.
The AT command is S-Register S61=n, where n is 0 for Disable, 1 for Fallback1, and 2 for Fallback2.
This configuration option does not appear when Async/Sync is configured for Sync.
DTE Rate = VF. Forces the DTE’s data rate to be equal to the VF (telephone line) data rate.
Disable – The data rate of the connection between the DTE and modem is the value of the Async DTE Rate configuration option.
Enable – The data rate between the DTE and modem is the same as the modem’s VF data rate. As a result, when the modem is in Data mode, the speed of the data passed between the modem and DTE occurs at the VF data rate.
The AT command is S-Register S90=n, where n is 0 for Disable and 1 for Enable.
DCP Configuration

(8 of 8) DTE Interface Configuration Options — Singleport Mode
Extend Main Ch.: Disable Nxt Disable Enable
Primary data can only be extended one link.
Extend Main Channel. This configuration option supports extended diagnostics. Specifies whether there is main (primary) channel connectivity between the modem’s DTE ports and the DTE ports of modems one level below (downstream) or above (upstream) in the diagnostic network.
Enable – If this configuration option is set to Enable on a port of a tributary modem, test mode is propagated to the modems downstream when test mode goes ON for that port.
Disable – If this configuration option is set to Disable on a port of a tributary modem, test mode is not propagated for that port and primary channel data is clamped when in test mode.
the main (primary) channel is extended.
This configuration only appears when the Extended Main Channel is enabled.
Upstream Port. When an extended control modem’s main (primary) channel is connected to a tributary modem that is one link above it in the diagnostic network, this configuration option is set to the port number to which it is connected on the tributary modem.

DTE Dialer — Singleport Mode
The DTE Dialer configuration options establish the DTE-to-modem protocol for call establishment and control.
Table 4-8 shows each DTE Dialer configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 5) DTE Dialer Configuration Options — Singleport Mode
Data Terminal Equipment Dialer Type. Identifies to the modem the type of dialing method and protocol used by the DTE.
Disable – Disables any type of DTE dialing method. Dialing can only be performed using the DCP’s Dial command or attached telephone.
AT – Allows AT command protocol to be used as a method for entering commands and dialing when used in an asynchronous application. This is the only valid setting for leased-line applications. The modem will not respond to AT commands if DTE Dialer Type is not set to AT.
V.25bis Async – Selects V.25bis Async as the dialing method and protocol used by the modem. The character length must be 7 data bits with even parity and 1 stop bit.
V.25bis Bisync – Selects V.25bis Bisync as the dialing method and protocol used by the modem. This is also known as character-oriented protocol. This framing protocol uses two synchronous control characters and a start-of-text control character before the text block and an end-of-text control character after the text block. The correct character structure for V.25bis Bisync dialing is 7 data bits, Odd parity, and 1 stop bit. If the modem is in Asynchronous mode, enter the following command string to configure it for V.25bis Bisync dialing: AT&F&D1&S1&M233&W. If the modem is already configured for synchronous operation, perform the following to set the character format: (1) use the modem’s front panel to access the Async/Sync Mode configuration option and set it to Async; (2) scroll down until the Asyn #Data Bits configuration option appears and set it to 7 data bits; (3) scroll down and set the Asyn Parity Bit configuration option to Odd; (4) scroll through the DTE Interface group until the Async/Sync Mode configuration option appears and set it to Sync; (5) move up one level in the menu tree or move to the Top-Level menu, and follow the LCD messages to save the new modem settings.
V.25bis HDLC – Selects V.25bis HDLC as the dialing method and protocol used by the modem. This is also known as bit-oriented protocol. This framing protocol uses flag, address and control characters before the text block and a frame sequence check and flag after the text block.
DTR=Direct1 – Allows the modem to automatically dial the number stored in directory location 1 whenever DTR turns ON. DTR dialing cannot be used if dial access security is enabled.
AT&T Exclusive – Enables a subset of the proprietary AT&T command set, which is required for some applications that use AT&T equipment. Currently, the only application supported is AT&T DATAKIT.
The AT commands for AT are &M0, &M1, &M3 or &Q0, &Q1, &Q3. The AT commands for DTR=Direct1 dialing are &M2 or &Q2.
DCP Configuration

(2 of 5) DTE Dialer Configuration Options — Singleport Mode
This configuration option only appears when DTE Dialer Type is configured for AT.
AT Escape Character. The escape sequence (+++) allows you to move from Data mode to Command mode. Use the ATO command to return to Data mode. The ASCII value of the escape character (43 ASCII) can be set to any ASCII value from 0 ASCII to 255 ASCII. However, the escape character is disabled if a value greater than 127 ASCII is entered. When disabled, the call must be disconnected to return to Command mode.
The AT command is S-Register S2=n, where n is a value from 0 to 127. The AT command to disable is S-Register S2=n where n is a value from 128 to 255. (When disabled, the modem cannot return to Command mode unless disconnected.)
This configuration option only appears if DTE Dialer Type is configured for AT.
Escape Guard Time. Determines the length of the required pause before and after the escape sequence is issued. The guard time prevents the modem from interpreting data as the escape sequence characters.
The AT command is S-Register S12=n, where n is a value from 0 to 255 in 20 millisecond increments.
This configuration option only appears when DTE Dialer Type is configured for AT.
Break Forces Escape. Determines whether or not the modem should enter Command mode when it receives a break character from the DTE.
Disable – A break character is sent to the remote end.
Enable – Modem escapes into AT Command mode, and a break character is not sent to the remote end.
The AT commands for Enable are \K0, \K2, or \K4. The AT commands for Disable are \K1, \K3, or \K5.
This configuration option only appears when DTE Dialer Type is configured for AT.
Command Character Echo. Controls whether or not characters are echoed back to the DTE when the modem is in Command mode.
The AT command for Disable is E0. The AT command for Enable is E1.
This configuration option only appears when DTE Dialer Type is configured for AT.
Carriage Return Character. Allows you to change the ASCII character used to terminate an AT command to any ASCII value from 0 to 127.
The AT command is S-Register S3=n, where n is a value from 0 to 127.
This configuration option only appears when DTE Dialer Type is configured for AT.
Backspace Character. Sets the character used to perform a backspace in Command mode.
The AT command is S-Register S5=n, where n is a value from 0 to 127.

(3 of 5) DTE Dialer Configuration Options — Singleport Mode
This configuration option only appears when DTE Dialer Type is configured for AT.
Line Feed Character. Sets the character used to perform a line feed in Command mode for responses from the modem.
The AT command is S-Register S4=n, where n is a value from 0 to 127.
This configuration option only appears when DTE Dialer Type is configured for AT.
Result Codes. Result codes are informational messages (such as Connect and Ring) sent from the modem and displayed on the asynchronous DTE terminal. (For a list of Result Codes, refer to Table 5-1 in Chapter 5, AT Commands and S-Registers.)
Enable – Modem sends result codes to the DTE.
Disable – Modem does not send result codes to the DTE.
Enable in Originate – For UNIX applications, enable result codes only on the originating modem. This prevents the DTE on the answer side from interpreting result codes as login attempts.
The AT command for Enable is Q0. The AT command for Disable is Q1. The AT command for Enable in Originate mode is Q2.
This configuration option only appears when DTE Dialer Type is configured for AT.
Extended Result Codes. Informational messages such as VF data rate and Error Control appear along with the result codes. (For a list of Extended Result Codes, refer to Table 5-1 in Chapter 5, AT Commands and S-Registers.)
Enable – NO DIALTONE, BUSY, NO ANSWER, and CONNECT xxxx (xxxx = VF data rate) appear along with result codes listed in Table 5-1 in Chapter 5.
Disable – Only OK, CONNECT, RING, NO CARRIER, and ERROR result codes appear.
Add/EC – Places the EC suffix after the result code text if error control is used. For example, CONNECT 9600/EC.
Add/V.42 or /MNP – Places either the /V.42 or /MNP suffix after the result code text if data compression is used. For example, CONNECT 9600/V42b.
Use DTE Rate – Allows the DTE rate to be displayed in the Connect message instead of the line rate. This feature is required in some modem pooling applications.
configuration option is enabled.
The AT command for Disable is X0. The AT commands for Enable are X1, X2, X3, or X4. The AT command for Add/EC is X5. The AT command for Add/V42, MNP is X6. The AT command for Use DTE Rate is X7.
DCP Configuration

(4 of 5) DTE Dialer Configuration Options — Singleport Mode
This configuration option only appears when DTE Dialer Type is configured for AT.
Result Codes Format. Controls whether or not result codes appear as words or as numeric codes. Some DTEs do not recognize Result Codes as words; therefore, numbers are required. The Numbers (2) format is required for some modem pooling applications. (For a list of Result Codes, refer to Table 5-1 in Chapter 5, AT Commands and S-Registers.)
The AT command for Numbers (1) is V0. The AT command for Words format is V1. The AT command for Numbers (2) is V2.
This configuration option only appears when DTE Dialer Type is configured for AT.
AT Command Mode. Determines how the modem responds to valid and invalid AT commands.
Normal – Allows normal operation of the AT command set. The modem acts upon all valid AT commands and issues the ERROR result code for invalid commands. If a string with multiple commands is entered, then an invalid command within that string will prevent the execution of subsequent valid commands.
No ERROR – Operates similar to Normal mode, however, the modem does not issue an ERROR result code for invalid commands. When an invalid command is encountered, the modem ignores it and issues the OK result code. If a string with multiple commands is entered, then an invalid command within that string will not prevent the execution of subsequent valid commands.
No Strap or ERROR – Ignores all AT commands (including valid commands) that cause a configuration option to change. Only non-configuring commands (for example ATD, ATA, and ATI) are executed; the ERROR result code is never returned.
can be changed by selecting a factory preset configuration via the DCP.
The AT command is S-Register S84=n, where n is 0 or 231 for Normal, 1 or 232 for No ERROR, and 2 or 233 for No Strap or ERROR.
This configuration option only appears when DTE Dialer is configured for V.25bis HDLC or V.25bis Bsync.
V.25bis Coding. Identifies to the modem whether the DTE is using ASCII code or EBCDIC code for V.25bis commands. The modem responds to the DTE using the same coding.
The AT command is S-Register S62=n, where n is 0 for ASCII or 1 for EBCDIC.

(5 of 5) DTE Dialer Configuration Options — Singleport Mode
This configuration option only appears when DTE Dialer is configured for V.25bis HDLC.
V.25bis Idle Fill. Determines whether a mark or flag is used as an idle fill character for the DTE. The modem responds to the DTE using the same idle fill.
The AT command is S-Register S63=n, where n is 0 for Mark or 1 for Flag.
This configuration option only appears when DTE Dialer is configured for V.25bis Async.
V.25bis New Line Character. Sets the modem for the command line terminator used by the DTE in V.25bis Async mode. The modem responds to the DTE using the same line terminator.
The AT command is S-Register S64=n, where n is 0 for carriage return and line feed, 1 for carriage return, or 2 for line feed.
DCP Configuration

Line Dialer — Singleport Mode
The Line Dialer configuration options establish parameters used by the modem to answer or originate calls.
Table 4-9 shows each Line Dialer configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 4) Line Dialer Configuration Options — Singleport Mode
Auto-Answer Ring Count. Determines the number of rings necessary before the answering modem answers an incoming call. For example, if this option is set to 2, then the answering modem answers after the second ring.
Disable – If selected, the modem must be answered using either the DCP’s Answer command or Tlk/Data function or via AT commands. Refer to Talk/Data in Chapter 3, DCP Operation, for more on Manual Answer.
255 rings.
The AT command for Disable is S0=0. The AT command is S-Register S0=n, where n is a ring count from 1 to 255.
Dialer Type. Selects either tone (DTMF) dialing or pulse (rotary) dialing mode.
The AT command for Tone is T. The AT command for Pulse is P.
Dial Tone Detect. Sets the modem for dial tone detection (enable) or blind dialing (disable).
Enable – Modem disconnects the call if a dial tone is not detected within 10 seconds and displays No Dial Tone on both the LCD and asynchronous DTE terminal.
Disable – Modem dials a call whether or not it detects a dial tone on the line. This is known as blind dialing. The period of time the modem waits before dialing is specified in the Blind Dial Paus configuration option.
The AT commands for Disable are X0, X1, and X3. The AT commands for Enable are X2, X4, X5, X6, and X7.
This configuration option only appears when Dial Tone Detect is configured for Disable.
Blind Dial Pause. Determines how long the modem waits before dialing a telephone number when Dialtone Detect is disabled.
The AT command is S-Register S6=n, where n is from 2 to 255 in 1-second increments.

(2 of 4) Line Dialer Configuration Options — Singleport Mode
Busy Tone Detect. Sets the modem to monitor for Busy Tone (Enable) or ignore Busy Tone (Disable).
configuration option can be disabled and the modem ignores all busy tones.
The AT commands for Disable are X0, X1, and X2. The AT commands for Enable are X3, X4, X5, X6, and X7.
Pause Time. Determines the number of seconds the modem pauses when it encounters a comma (,) in the dial command string.
255 seconds.
The AT command is S-Register S8=n, where n is from 0 to 255 in 1-second increments.
No Answer Abort Time-out. Determines the number of seconds an originating modem waits before abandoning a call attempt when no answer tone is received.
255 seconds.
The AT command is S-Register S7=n, where n is from 1 to 255 in 1-second increments.
Fast Disconnect. Allows the modem to disconnect immediately after receiving a disconnect command from a local DTE or its own diagnostic control panel.
Disable – The modem follows its normal disconnect sequence by issuing a cleardown sequence or long space disconnect. This is also known as a graceful disconnect since the other modem receives advance notice of a disconnection.
Enable – Use this setting if the DTE requires that the modem be made available as soon as possible after receiving a disconnect command.
disconnection as an error instead of a valid disconnect.
The AT command is S-Register S85=n, where n is 0 for Disable and 1 for Enable.
This configuration option does not appear on Models 3920Plus-A1-401 and 3921Plus-B1-001.
Line Current Disconnect. Determines the modem’s response to short interruptions of line current. The loss of line current is one method of disconnecting a call.
Enable > 8-millisecond – Disconnects the modems if line current is disrupted for more than 8 milliseconds.
Enable > 90-millisecond – Disconnects the modems if line current is disrupted for more than 90 milliseconds. Use this setting if the modem constantly disconnects when set to Enab(>8msec).
Disable – Ignores any disruptions in line current such as call waiting.
The AT command is S-Register S65=n, where n is 0 for Enable (>8 msec), 1 for Enable (>90 msec), and 2 for Disable.
DCP Configuration

(3 of 4) Line Dialer Configuration Options — Singleport Mode
Long Space Disconnect. Determines the modem’s response to a continuous spacing condition sent from the remote modem before it goes on-hook. Issuing a long space is one method of disconnecting a call.
Enable – Modem disconnects if it receives a continuous space from the DTE. For modulations lower than 4800 bps, the modem’s transmitter will transmit 4 seconds of long space upon a disconnect.
Disable – Modem does not disconnect if it receives a continuous space from the DTE. Modem will not transmit a long space disconnect.
The AT command for Disable is Y0. The AT command for Enable is Y1.
No Carrier Disconnect. If the modem no longer receives carrier from the remote modem, it disconnects the call. This configuration option determines how long carrier is OFF before the modem disconnects. Loss of carrier is one method of disconnecting a call.
2, 5, 10, 20 sec – Modem disconnects if carrier turns OFF for more than 2 seconds, 5 seconds, 10 seconds, or 20 seconds.
Disable – Modem does not disconnect if carrier turns OFF.
The AT command is S-Register S10=n, where n is 255 for Disable or 0 to 254 in 0.1 second increments for Enable.
No Data Disconnect. Forces the modem to disconnect if no data is transmitted and received within a specified amount of time.
Disable – Modem remains connected despite the lack of data flow.
10, 30, 60 min – Modem disconnects if data is not received and transmitted within 10-minute, 30-minute, or 60-minute intervals.
The AT command for Enable is \Tn, where n is from 1 minute to 255 minutes. The AT command for Disable is \T0.

(4 of 4) Line Dialer Configuration Options — Singleport Mode
This option is only valid on Model 3921Plus.
Automatic Make Busy. Forces the modem to go off-hook under the following conditions: if a local analog loopback is performed, a self-test is performed, or if the modem is switched to the service line.
Exchange (PBX). The Make Busy Network Interface Module (NIM) must be installed on the COMSPHERE 3000 Series Carrier. Refer to the COMSPHERE 3000 Series Carrier, Installation Manual.
The AT command is S-Register S40=n, where n is 0 for Disable and 1 for Enable.
Make Busy Via DTR. Determines if the modem goes off-hook when DTR is OFF. Enable this setting if the DTE normally keeps DTR ON and turns DTR OFF when the DTE cannot accept a call.
Exchange (PBX). For 3921Plus modems, the Make Busy Network Interface Modules (NIMs) must be installed on the COMSPHERE 3000 Series Carrier. Refer to the COMSPHERE 3000 Series Carrier, Installation Manual.
The AT command is S-Register S69=n, where n is 0 for Disable and 1 for Enable.
DCP Configuration

Dial Line — Singleport Mode
The Dial Line configuration options are used to configure the modem for operation over dial lines.
Table 4-10 shows each Dial Line configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 3) Dial Line Configuration Options — Singleport Mode
Dial Modulation. Modulation reduces the amount of scrolling necessary to select Dial Line rates by limiting the number of Dial Line Rate configuration options. Only one group of Dial Line rates is displayed depending on the setting of the Dial Modulation configuration option (V.34, V.32bis, V.32 terbo, V.21, V.22, V.23, Bell 212A, and Bell 103J).
Dial Line Rate: 28800(V34) Nxt 33600 31200 28800(V34) 26400(V34) 24000(V34) 21600(V34) 19200(V34) 16800(V34) 14400(V34) 12000(V34) 9600(V34) 7200(V34) 4800(V34) 2400(V34) 19200(V32t) 16800(V32t) 14400(V32b) 12000(V32b) 9600(V32b) 7200(V32b) 4800(V32b) 2400(V22bis) 1200 (V22) 1200(212A) 0–300(V21) 0–300(103J) 1200/75(V23) 75/1200(V23) 600/75(V23) 75/600(V23)
Dial Line Rate. This configuration option determines the modem’s data rate and modulation scheme for operation on dial lines. Online changes do not take effect until a disconnect occurs.
33600, 31200, 28800(V34), 26400(V34), 24000(V34), 21600(V34), 19200(V34), 16800(V34), 14400(V34), 12000(V34), 9600(V34), 7200(V34), 4800(V34), 2400(V34) – The modem operates using V.34 modulation at the data rate selected.
19200(V32t), 16800(V32t), 14400(V32b), 12000(V32b), 9600(V32b), 7200(V32b), 4800(V32b) – The modem operates using V.32 terbo, V.32bis, or V.32 modulation at the data rate selected.
2400(V22bis), 1200 (V22), 1200(212A) – Modem operates using the modulation and data rate selected.
0–300(V21), 0–300(103J) – Modem operates in full-duplex, Asynchronous mode. These data rates do not support V.42 or MNP error control.
1200/75(V23), 75/1200(V23), 600/75(V23), 75/600(V23) – The modem will run in asynchronous semi-full duplex mode at the rate chosen.
The AT command is S-Register S41=n, where n is:
1 = 14,400 (V.32bis) 10 = 0–300 (V.21) 22 = 33,600 30 = 14,400 (V.34) 2 = 12,000 (V.32bis) 11 = 0–300 (103J) 23 = 31,200 31 = 12,000 (V.34) 3 = 9600 (V.32bis/V.32) 12 = 1200/75 (V.23) 24 = 28,800 (V.34) 32 = 9600 (V.34) 4 = 7200 (V.32bis) 13 = 75/1200 (V.23) 25 = 26,400 (V.34) 33 = 7200 (V.34) 5 = 4800 (V.32bis/V.32) 18 = 600/75 (V.23) 26 = 24,000 (V.34) 34 = 4800 (V.34) 6 = 2400 (V.22bis) 19 = 75/600 (V.23) 27 = 21,600 (V.34) 35 = 2400 (V.34) 7 = 1200 (V.22) 20 = 19,200 (V.32 terbo) 28 = 19,200 (V.34) 8 = 1200 (212A) 21 = 16,800 (V.32 terbo) 29 = 16,800 (V.34)

(2 of 3) Dial Line Configuration Options — Singleport Mode
This configuration option only appears when Dial Line Rate is configured for V.32 or V.34 families data rate.
Automode. The modem automatically adapts to the modulation scheme and line rate of the remote modem. However, the maximum data rate the modem uses is determined by the Dial Line Rate configuration option.
System 85 – Enables the full automode function with special provisions which are needed to work reliably in a System 85 or similar PBX modem pool.
the Automoding sequence. Instead, the modem uses the Bell 103J protocol for 0–300 bps operation.
The AT command is S-Register S78=n, where n is 0 for Enable, 1 for Disable, and 2 for System 85.
This configuration option only appears when Dial Line Rate is configured for V.32 or V.34 families data rate.
Autorate. Once connected, the modem automatically lowers the line rate if line conditions become impaired. When line conditions improve, the modem automatically shifts up to the highest data rate the line can support. This autorating only occurs between 19,200 bps and 4800 bps during V.32, V.32bis, and V.32 terbo connections and 33.6 and 2400 bps for the V.34 family.
Start at 48 and Start at 96 – Set the maximum connect rate for V.32, V.32bis, and V.32 terbo connections.
The AT command is S-Register S76=n, where n is 0 for Enable, 1 for Disable, 2 for Start at 48, and 3 for Start at 96.
This configuration option is ignored unless Dial Line Rate is 4800(V32b).
V.32bis Override. Activates the Paradyne Point-to-Point Diagnostic 2400 bps modulation. Allows the modem to use a non-standard, point-to-point modulation capable of secondary channel diagnostics while running at 2400 bps.
Dial Tx Level: Permissv(–9) Nxt Permissv(–9) –10 –11 –12 –13 –14 –15 –16 –17 –18 –19 –20 –21 –22 –23 –24 –25 –26 –27 –28 –29 –30 –31 –32
Dial Transmit Level. Selects the modem’s transmit power level over dial lines. The transmit output level can be selected in 1 dBm decrements from –9 dBm to –32 dBm.
option is locked in other some countries (the user cannot change the level).
The AT command is &In, where n is from 10 to 32 corresponding to –10 dBm to –32 dBm.
DCP Configuration

(3 of 3) Dial Line Configuration Options — Singleport Mode
This configuration option only appears when Dial Line Rate is configured for V.22bis or V.22 data rate, or when Automode is configured for Enable.
V.22bis Guard Tone. Determines whether the V.22bis guard tone is disabled, set to 550 Hz, or set to 1800 Hz.
Disable – No guard tone.
550 Hz or 1800 Hz – When the modem is in Answer mode, it transmits the guard tone at this frequency.
The AT command for Disable is &G0. The AT command for 550 Hz is &G1. The AT command for 1800 Hz is &G2.
This configuration option only appears when Dial Line Rate is configured for V.34 and V.32 families.
Train Time. Controls V.34 and V.32 families train time. Determines whether minimum or maximum time durations are used during the V.34 and V.32 families handshaking sequence for both dial and 4-wire/2-wire leased-line applications.
Long – Selects long train. Use this setting whenever far-end frequency offset (phase roll) may be encountered. This is usually only required when transmitting over satellite links.
Short – Allows the modem to train-up faster when using the V.34 and V.32 families modulation.
The AT command is S-Register S43=n, where n is 0 for Long and 1 for Short.
This configuration option does not appear unless V.34 modulation is selected.
Asymmetric Rate. Controls rate symmetry when running V.34 modulation by enabling or disabling the V.34 modulation from using equal transmit and receive rates.
Enable – The modem operates in asymmetric rate mode (the transmit and receive rates can be different) when running V.34 modulation. The Asymmetric Rate configuration option must be enabled in both modems.
Disable – The modem operates in symmetric rate mode (the transmit and receive rates are identical) when running V.34 modulation. Either modem can force symmetric mode by disabling the Asymmetric Rate configuration option.
The AT command is S-Register S14=n, where n is 0 for Enable and 1 for Disable.

Leased Line — Singleport Mode
The Leased Line configuration options only appear when the Sync Leased factory preset template is selected. They are used to configure the modem for operation over leased lines.
Table 4-11 shows each Leased Line configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 5) Leased Line Configuration Options— Singleport Mode
Lease Modulation. Modulation reduces the amount of scrolling necessary to select Leased Line rates by limiting the number of Leased Line Rate configuration options. Only one group of Leased Line rates is displayed depending on the setting of the Lease Modulation configuration option (V.34, V.32bis, V.32terbo, TMp, V.33, V.29, V.27bis, V.22bis).
LeasedLine Rate: 28800(V34) Nxt 33600 31200 28800(V34) 26400(V34) 24000(V34) 21600(V34) 19200(V34) 16800(V34) 14400(V34) 12000(V34) 9600(V34) 7200(V34) 4800(V34) 2400(V34) 19200(V32t) 16800(V32t) 14400(V32b) 12000(V32b) 9600(V32b) 7200(V32b) 4800(V32b) 19200(TMp), 14400(TMp) 9600(TMp) 7200(TMp) 4800(TMp) 2400(TMp) 2400(V22bis) 14400(V33) 12000(V33) 9600(V29) 7200(V29) 4800(V29) 4800(V27bis) 2400(V27bis)
Leased-Line Rate. Determines the modem’s data rate and modulation scheme for operation on leased lines.
33600, 31200, 28800(V34), 26400(V34), 24000(V34), 21600(V34), 19200(V34), 16800(V34), 14400(V34) 12000(V34), 9600(V34), 7200(V34), 4800(V34), 2400(V34) – The modem operates using V.34 modulation at the data rate selected.
19200(V32t), 16800(V32t), 14400(V32b), 12000(V32b), 9600(V32b), 7200(V32b), 4800(V32b) – The modem operates using V.32bis or V.32 terbo modulation at the data rate selected. These modulation schemes are available on 2-wire or 4-wire leased lines.
19200(TMp), 14400(TMp), 9600(TMp), 7200(TMp), 4800(TMp), 2400(TMp) – The modem operates in Trellis Multipoint mode at the data rate selected. These modulation schemes are available on 4-wire leased lines. The 19200(TMp) modulation does not appear on tributary modems.
NOTE: TMp control modems can accept mixed inbound rates from tributary modems. For example, one inbound link may be configured for 14.4 kbps while another link experiencing line impairments may be configured for 9.6 kbps. The following control/tributary rate combinations are allowed: control at 19.2 kbps, tributaries at 14.4 or 9.6 kbps; control at 14.4 kbps, tributaries at 14.4 or 9.6 kbps; control at 9.6 kbps, tributaries at 9.6 or 7.2 kbps; control at 7.2 kbps, tributaries at 7.2 or 4.8 kbps; control at 4.8 kbps, tributaries at 4.8 or 2.4 kbps; control at 2.4 kbps, tributaries at 2.4 kbps. Tributary rates will never exceed control rates. If tributary and control rates are equal, reducing the control rate will automatically reduce the tributary rate.
2400(V22bis) – This modulation scheme is available on 2-wire and 4-wire leased lines.
14400(V33), 12000(V33) – These modulation schemes are only available on 4-wire leased lines.
9600(V29), 7200(V29), 4800(V29) – These modulation schemes are only available on 4-wire leased lines.
DCP Configuration

(2 of 5) Leased Line Configuration Options— Singleport Mode
4800(V27bis), 2400(V27bis) – This modulation scheme is available on 2-wire (half-duplex) and 4-wire leased lines.
or TMp to another leased-line modulation (V.33, V.29, or V.22bis). See Err Contrl Mode configuration option for more about Direct mode. On leased lines, V.42 error control and Buffer mode are only supported by V.32bis, V.34 family, or TMp. An error occurs if the modem is not in Direct mode when the modulation is changed from V.32bis, V.34 family, or TMp.
The AT command is S-Register S44=n, where n is:
1 = 14,400 (V.32bis) 14 = 7200 (V.29) 23 = 7200 (TMp) 32 = 19,200 (V.34) 2 = 12,000 (V.32bis) 15 = 4800 (V.29) 24 = 4800 (TMp) 33 = 16,800 (V.34) 3 = 9600 (V.32bis) 16 = 4800 (V.27bis) 25 = 2400 (TMp) 34 = 14,400 (V.34) 4 = 7200 (V.32bis) 17 = 2400 (V.27bis) 26 = 33,600 35 = 12,000 (V.34) 5 = 4800 (V.32bis) 18 = 19,200 (V.32 terbo) 27 = 31,200 36 = 9600 (V.34) 6 = 2400 (V.22bis) 19 = 16,800 (V.32 terbo) 28 = 28,800 (V.34) 37 = 7200 (V.34) 11 = 14,400 (V.33) 20 = 19,200 (TMp) 29 = 26,400 (V.34) 38 = 4800 (V.34) 12 = 12,000 (V.33) 21 = 14,400 (TMp) 30 = 24,000 (V.34) 39 = 2400 (V.34) 13 = 9600 (V.29) 22 = 9600 (TMp) 31 = 21,600 (V.34)
Leased Mode. Sets the modem for either 2-wire or 4-wire operation in Answer mode (receiving a call) or 2-wire or 4-wire operation in Originate (initiating a call) mode.
other set to Answer mode.
For Sync Leased Answer Mode, Async Leased Answer Mode and Trellis Multipoint Tributary Mode, 4-wire Answer is the factory default.
For Sync Leased Originate Mode, Async Leased Originate Mode and Trellis Multipoint Control Mode, 4-wire Originate is the factory default.
The AT command for Disable is &L0. The AT command for 2-wire Originate is &L1. The AT command for 4-wire Originate is &L2. The AT command for 2-wire Answer is &L3. The AT command for 4-wire Answer is &L4.
This configuration option only appears when Leased Line Rate is configured for V.34 and V.32 families data rate.
Autorate. Once connected, the modem automatically lowers the line rate if line conditions become impaired. When line conditions improve, the modem automatically shifts up to the highest data rate the line can support. This autorating only occurs between 19,200 bps and 4800 bps during V.32, V.32bis, and V.32 terbo connections and 33.6 and 2400 for V.34.
The AT command is S-Register S82=n, where n is 0 for Enable and 1 for Disable.
This configuration option is ignored unless Leased-Line Rate is 4800(V32b).
V.32bis 4800 Override. Activates the Paradyne Point-to-Point Diagnostic 2400 bps modulation. Allows the modem to use a non-standard, point-to-point modulation capable of secondary channel diagnostics while running at 2400 bps.

(3 of 5) Leased Line Configuration Options— Singleport Mode
Leased Tx Level: 0 Nxt 0 –1 –2 –3 –4 –5 –6 –7 –8 –9 –10 –11 –12 –13 –14 –15
Leased Transmit Level. Selects the modem’s transmit power level over leased lines. The transmit output level can be selected in 1 dBm decrements from 0 dBm to –15 dBm.
The AT command is S-Register S45=n, where n is from 0 to 15 corresponding to 0 dBm to –15 dBm.
This configuration option does not appear unless V.34 is enabled.
Asymmetric Rate. Controls rate symmetry when running V.34 modulation by enabling or disabling the V.34 modulation from using equal transmit and receive rates.
Enable – The modem operates in Asymmetric Rate mode (the transmit and receive rates can be different) when running V.34 modulation. The Asymmetric Rate configuration option must be enabled in both modems.
Disable – The modem operates in symmetric rate mode (the transmit and receive rates are identical) when running V.34 modulation. Either modem can force Symmetric mode by disabling the Asymmetric Rate configuration option.
The AT command is S-Register S15=n, where n is 0 for Enable and 1 for Disable.
Automatic Dial Backup. Allows the modem to dial the number stored in directory location 1 to restore communications with the remote modem when the leased lines fail.
modem. The answering modem must have its Auto-Answer Ring Number configuration option enabled. Refer to the Line Dialer configuration option group for information regarding Auto-Answer.
10 call attempts, with a 2 minute delay between calls. This function can be reset with a completed manual dial backup, a power cycle, or using NMS.
Fast Backup – Only used in special applications requiring a shortened delay time from the failure of the leased lines to the initiation of the automatic dial backup.
The AT command is S-Register S46=n, where n is 0 for Disable, 1 for Enable, and 2 for FastBackup.
AutoDialStandby: Disable Nxt Disable 15min 1hr 4hr Test(2min) Adv 15min Adv 30min Adv 1 hr TestAdv2min
Automatic Dial Standby. Permits a modem operating on dial lines (regardless of the method of dialing origination) to check the quality of the leased lines periodically and, if they are good, to disconnect from the dial lines and resume operations on the leased lines. The time interval that the modem uses to check the quality of the leased lines is determined by the configuration option. These intervals are 15 minutes, 1 hour, and 4 hours. The Test(2min) and TestAdv2min selections are for testing purposes only. The Adv 15min, Adv 30min, and Adv 1 hr selections cause the modem to evaluate the leased lines continuously in a manner which is non-disruptive to the dial-line communication.
The AT command is S-Register S47=n, where n is 0 for Disable, 1 for 15min, 2 for 1hr, 3 for 4hrs, 4 for Test(2min), 5 for Adv 15min, 6 for Adv 30min, 7 for Adv 1 hr, and 8 for TestAdv2min.
DCP Configuration

(4 of 5) Leased Line Configuration Options— Singleport Mode
This configuration option only appears when Automatic Dial Standby is configured for 15min, 1hr, 4hr or Test(2min) and Leased mode is configured for Originate mode, or when Automatic Dial Standby is configured for Adv15min, Adv30min, Adv1hr or TestAdv(2min).
Special Standby. Used to support Automatic Dial Standby configurations when a third modem is used for the dial backup. When the leased line is restored, the Special Standby configuration allows the leased-line modems to return service to the original point-to-point modems.
configuration option allows the originate modem to test the lease connection in one direction before interrupting primary data on the dial lines.
Special Standby configuration option allows a non-interruptive algorithm to test the original point-to-point lease connection in both directions before interrupting primary data on the dial lines.
The AT command is S-Register S98=n, where n is 0 for Disable and 1 for Enable.
Dial Standby Time. Selects the amount of time that a dial circuit is held after returning to the leased lines.
Carrier On Level. Controls the carrier detection threshold for leased lines. When the power level of the receive carrier signal drops 2 dBm below this level (either –26 dBm or –43 dBm), LSD turns OFF. When the carrier signal is greater than this level, LSD turns ON.
For TMp Control, –26dbm is the factory default.
The AT command is S-Register S48=n, where n is 0 for –43 dBm and 1 for –26 dBm.
This configuration option only appears when Leased-Line Rate is configured for V27bis.
V.27bis Train. Controls the train time for V.27bis operation.
The AT command is S-Register S70=n, where n is 0 for Short and 1 for Long.
This configuration option only appears when Leased-Line Rate is configured for V29.
V.29 Train On Data. When enabled, the modem receiver can train based upon the incoming data or a training sequence from the distant modem. This function is necessary for a remote (tributary) modem in a V.29 multipoint network and is recommended for a control modem as well.
The AT command is S-Register S92=n, where n is 0 for Disable and 1 for Enable.
This configuration option only appears when Leased-Line Rate is configured for V29.
V.29 Retrain. When enabled, the modem transmits a training sequence whenever it receives one. This configuration option should normally be disabled for control modems.
The AT command is S-Register S93=n, where n is 0 for Enable and 1 for Disable.

(5 of 5) Leased Line Configuration Options— Singleport Mode
This configuration option only appears when Leased-Line Rate is configured for V29.
V.29 Link Configuration. Selects point-to-point or multipoint operation.
The AT command is S-Register S94=n, where n is 0 for PointToPoint and 1 for Multipoint.
This configuration option only appears when Leased-Line Rate is configured for TMp.
Trellis Multipoint (TMp) Train Time. Defines the length of time energy is sent from the tributary modem to the control modem. More severe line conditions require longer time selections.
The AT command is S-Register S95=n, where n is 0 for 10 milliseconds, 1 for 20 milliseconds, 2 for 50 milliseconds, 3 for 100 milliseconds, 4 for 200 milliseconds, and 5 for 300 milliseconds.
This configuration option only appears if Leased-Line Rate is configured for TMp.
Trellis Multipoint (TMp) Transmit Preemphasis. Provides amplification for frequencies above the carrier frequency to compensate for high frequency line attenuation.
The AT command is S-Register S96=n, where n is 0 for Enable and 1 for Disable.
Lease Lookback. While operating on backup lines, this configuration option allows the modem to test the primary 4-wire leased lines for connectivity by detecting line energy across the normal line bandwidth. This test of the primary lines will not interrupt the data flow on the backup lines. The configuration option settings must be the same at both ends.
Dual Leased Line. Allows the 2-wire backup facility to function as a 2-wire leased line facility. When this option is disabled, the backup facility is a 2-wire dial line.
Except for dialing, ring indication, and call progression functions, you control the backup function as if it were a normal dial backup.
This configuration option is only available when the Dual Leased Line device option is enabled and the V.34 is disabled in the LeaseLine Rate configuration option.
Backup Line Check. Tests the backup circuit for availability while the modem is operating on the primary 4-wire leased lines. The test involves detecting line energy across the normal bandwidth. This test of the backup lines will not interrupt the data flow on the primary lines. The configuration option settings must be the same at both ends.
modem connected to the primary leased-line, enabling this configuration can cause problems.
DCP Configuration

V.42/MNP/Buffer — Singleport Mode
V.42/MNP/Buffer configuration options determine the type of error correction and flow control used by the modems and attached DTEs.
Some choices within this group may not appear depending upon how previous configuration options have been selected. If the Async/Sync Mode configuration option is set for synchronous operation (refer to the DTE Interface configuration options group), then the V.42/MNP/Buffer group does not appear on the LCD. Any changes made to configuration options within this group only take effect after a disconnect.
Table 4-12 shows each V.42/MNP/Buffer configuration option as it appears on the LCD, with the Async Dial factory default setting shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 6) V.42/MNP/Buffer Configuration Options — Singleport Mode
This configuration option only appears if Async/Sync Mode is configured for Async.
Error Control Mode. Determines the type of error control used by the modem. In most cases, V42/MNPorBfr is the best choice. If V.42bis and MNP are enabled, then the modem uses the following priority for error control negotiation: V.42bis, V.42, MNP 5 and below. Online changes do not take effect until a disconnect occurs.
V.42/MNP or Buffer – Modem attempts to connect in V.42 Error Control mode using V.42 Link Access Procedure for Modems (LAPM) protocol. If this fails, the modem attempts to connect in MNP mode. If this fails, the modem connects in Buffer mode and continues operation. This is also known as V42/MNP Autoreliable Mode.
V.42/MNP or Disconnect – Modem attempts to connect in V.42 Error Control mode using V.42 LAPM protocol. If this fails, the modem attempts to connect in MNP mode. If this fails, the modem disconnects. This is also known as Reliable mode.
MNP or Buffer – Modem attempts to connect in MNP mode. If this fails, the modem connects in Buffer mode. This is also known as MNP Autoreliable Mode.
MNP or Disconnect – Modem attempts to connect in MNP mode. If this fails, the modem disconnects. This is also known as Reliable mode.
Buffer Mode – Modem does not use error control and allows the DTE rate to differ from the communications line rate. This mode should only be used if the DTE provides its own error control or if errors in data can be tolerated. This setting is also known as Normal mode and is valid even if the remote modem is set to Direct mode.
Direct Mode – Modem connects at a data rate equal to or less than the initial DTE interface rate. (The modem never connects at a data rate greater than the initial DTE rate.) If the modem connects at a data rate lower than the DTE rate, the DTE must then adjust its data rate to equal the modem rate. Ultimately, the modem speed and DTE speed must be the same. Direct mode does not support error control or data buffering.
LAPM or Disconnect – Modem attempts to connect in LAPM mode. If this fails, the modem disconnects.
LAPM or Buffer – Modem attempts to connect in LAPM mode. If this fails, the modem connects in Buffer mode.
control or Buffer mode are enabled with V.32bis, V.34 family, or TMp on leased lines.

(2 of 6) V.42/MNP/Buffer Configuration Options — Singleport Mode
The AT command for Buffer Mode is \N0. The AT command for Direct Mode is \N1. The AT command for MNP or Disconnect is \N2. The AT command for MNP or Buffer is \N3. The AT command for V42/MNP or Disconnect is \N4. The AT command for V42/MNP or Buffer is \N5. The AT command for LAPM or Disconnect is \N6. The AT command for LAPM or Buffer is \N7.
This configuration option only appears when Async/Sync Mode is configured for Async, and Error Control Mode is configured for V42/MNPorBfr or V42/MNPorDsc.
V.42bis Data Compression. Enables or disables V.42bis data compression.
Enable – Data compression operates in both the transmit and receive directions. This is the recommended setting for all applications.
Disable – V.42bis data compression is disabled. This is rarely needed because V.42bis data compression does not cause data expansion for compressed data.
The AT command for Disable is H0. The AT command for Enable is H1, H2, or H3.
This configuration option only appears when Async/Sync Mode is configured for Async, and Error Control Mode is configured for V42/MNPorBfr, V42/MNPorDsc, MNP_or_Buffr, or MNP_or_Disc.
MNP5 Compression. Determines if the modem uses MNP Class 5 data compression. It can be set independently of V.42bis data compression. Online changes do not take effect until a disconnect occurs.
The AT command for Disable is %C0. The AT command for Enable is %C1.
This configuration option only appears when Async/Sync Mode is configured for Async, and Error Control Mode is configured for V42/MNPorBfr, MNP_or_Buffr, or LAPM_or_Bufr.
Error Control Negotiate Buffer. Determines if the answering modem buffers the data that it received from the remote modem during an interval in which the modem attempts to establish a connection using error control. Online changes do not take effect until a disconnect occurs.
Disable – Data is not buffered during the link negotiating (handshaking) sequence.
Enable – Data is buffered while the link is being established. Initialization data is not passed on the DTE during the handshaking sequence.
Disable and Switch – Data is not buffered during the handshaking sequence. However, when the modem receives an error control fallback character, it switches to Buffer mode. (Refer to the EC Fallback Char configuration option.)
The AT command for Disable is \C0. The AT command for Enable is \C1. The AT command for Disab&Switch is \C2.
DCP Configuration

(3 of 6) V.42/MNP/Buffer Configuration Options — Singleport Mode
This configuration option only appears when Async/Sync Mode is configured for Async, and EC Negotiate Buffer is not configured for Disable.
Error Control Fallback Character. This configuration option allows you to enter the ASCII value of the error control fallback character. This provides the remote modem with the ability to end the error control link negotiating (handshaking) sequence by sending this character. The modems will connect in Buffer mode (no error control). Online changes do not take effect until a disconnect occurs. When the modem receives this fallback character it switches to Buffer mode and transmits an EC fallback character to the DTE. When comparing incoming characters for a match against the EC fallback character, the modem ignores parity.
The AT command is %An, where n is a value from 0 to 127.
This configuration option only appears when Async/Sync Mode is configured for Async, and Error Control Mode is not configured for DirectMode.
Flow Control of DTE. Determines how the modem controls the flow of data from the DTE.
CTS to DTE – Method of flow control in which the modem raises and lowers its CTS interface lead to indicate when the DTE should start and stop sending data.
Disable – The modem cannot control the flow of data from the DTE.
XON/XOFF – Method of flow control in which the modem sends XON and XOFF characters to the DTE to start and stop the flow of data.
The AT commands for Disable are \Q0, \Q5, and \Q6. The AT commands for XON/XOFF are \Q1 and\Q4. The AT commands for CTS to DTE are \Q2 and \Q3.
This configuration option only appears when Async/Sync Mode is configured for Async, and Error Control Mode is not configured for DirectMode.
Flow Control of Modem. Determines how the DTE controls the flow of data from the modem.
RTS to Modem – Method of flow control in which the modem respectively starts and stops data transmission based upon the ON and OFF state of the DTE’s RTS signal.
Disable – The DTE cannot control the flow of data from the modem.
XON/XOFF – Method of flow control in which the modem starts and stops data flow based upon XON and XOFF characters received from the DTE.
The AT commands for Disable are \Q0, \Q2, and \Q4. The AT commands for XON/XOFF are \Q1 and\Q5. The AT commands for RTS to Modem are \Q3 and \Q6.

(4 of 6) V.42/MNP/Buffer Configuration Options — Singleport Mode
This configuration option only appears when Async/Sync Mode is configured for Async, and Flow Control of Modem is configured for XON/XOFF Psthru.
XON/XOFF Passthrough. Considers an XON/XOFF character as data and passes it on to the remote modem. In this case, the DTE at one end of the communications link can send flow control characters to the other DTE. This is also known as DTE to DTE flow control.
Disable – Flow control characters are processed but are not passed on to the remote modem.
Enable – Flow control characters are processed and passed on to the remote modem.
The AT command for Disable is \X0. The AT command for Enable is \X1.
This configuration option only appears when Async/Sync Mode is configured for Async, and Error Control Mode is configured for V42/MNPorBfr, MNP_or_Buffr, LAPM_or_Bufr, or BufferMode.
Modem-to-Modem Flow Control. If a modem’s buffers begin to fill due to data it is receiving from the remote modem, but is not passing on to the DTE, it can issue XON/XOFF flow control characters to the remote modem. This only applies if Buffer (nonerror control) mode is selected. If Error Control mode is enabled, flow control between the modems will happen automatically, regardless of the setting of this option.
Disable – Modem does not respond to XON and XOFF characters received over the VF line. Also, the modem will not transmit an XOFF character to the remote end if its receive buffers are full.
Enable – Modem stops transmitting data to the remote modem if it receives an XOFF character over the VF line. An XON character will enable data transmission. Also, the modem will transmit an XOFF character to the remote end if its receive buffers are full. Select this setting if the DTE rate is less than the VF line rate or if the DTE must frequently stop the flow of data to process it.
The AT Command for Disable is \G0. The AT Command for Enable is \G1.
This configuration option only appears when Async/Sync Mode is configured for Async, and Error Control Mode is not configured for DirectMode.
Break Buffer Control. Determines if data stored in the modem’s buffer is saved or discarded when the DTE issues a break sequence.
Keep Data (Nondestructive mode) – Saves the data in the buffer in both the local and remote modems.
Discard Data (Destructive mode) – Empties the data buffer. Only buffers in the same direction of travel as the break are discarded.
configuration options group) is enabled.
The AT commands for Discard Data are \K0 and \K1. The AT commands for Keep Data are \K2, \K3, \K4, and \K5.
DCP Configuration

(5 of 6) V.42/MNP/Buffer Configuration Options — Singleport Mode
This configuration option only appears when Async/Sync Mode is configured for Async, and Error Control Mode is not configured for DirectMode.
Send Break Control. Determines what is sent from the modem first, data or break if a break sequence is sent from the DTE.
Data First (Nonexpedited) – A break is treated as a data character and is sent in the order it was received. This is also known as Nonexpedited mode.
Break First (Expedited) – A break is sent before the data currently in the buffer. This is also known as Expedited mode.
configuration options group) is enabled.
The AT commands for Break First are \K0, \K1, \K2, and \K3. The AT commands for Data First are \K4 and \K5.
This configuration option only appears when Async/Sync Mode is configured for Async, and Error Control Mode is not configured for DirectMode.
Buffer Disconnect Delay. Determines how long the modem continues to transmit data stored in its buffers when the modem is commanded to disconnect by a locally attached DTE. This also applies to the modem’s receiving buffers when it is commanded to disconnect from a remote modem or DTE.
Disable – Modem disconnects immediately without attempting to send data stored in its buffers.
10, 60 sec – Maximum amount of time the modem tries to empty its buffers before disconnecting. In both cases (10 sec and 60 sec), the modem disconnects much sooner if it can empty its buffers.
The AT command is S-Register S49=n, where n is 0 for Disable and any value from 1 to 255 in 1 second increments.
This configuration option only appears when Async/Sync Mode is configured for Async, and Error Control Mode is not configured for BufferMode or DirectMode.
Maximum Frame Size. Sets the maximum frame size for V.42 and MNP. For V.42 operation, 128 is the maximum value. Any value which exceeds this will automatically default to 128 for V.42. For MNP operation, 64 is the minimum value. Any value less than that will automatically default to 64. For cellular applications, at least one of the sides should be set to a low value. A setting of 32 is recommended. Only one modem needs this setting; both modems will automatically default to the greatest common value.
The AT Command for 256 is \A3. The AT Command for 192 is \A2. The AT Command for 128 is \A1. The AT Command for 64 is \A0. The AT Command for 32 is \A4. The AT Command for 16 is \A5.

(6 of 6) V.42/MNP/Buffer Configuration Options — Singleport Mode
This configuration option only appears when Async/Sync Mode is configured for Async, and Error Control Mode is configured for V42/MNPorBfr, V42/MNPorDsc, LAPM_or_Disc, or LAPM_or_Bufr.
Cellular Enhancement. When enabled, the modem uses non-standard techniques to enhance V.42 operation for cellular applications. It is still compatible, however, with modems which do not have the cellular enhancement implemented or enabled.
The AT command is S-Register S91=n, where n is 0 for Disable and 1 for Enable.
This configuration option only appears when Async/Sync Mode is configured for Async, and Error Control Mode is configured for BufferMode.
Reduced Asynchronous Buffer Size. When enabled, the modem’s buffer size is limited to a maximum of 20 characters.
The AT command is S-Register S97=n, where n is 0 for Disable and 1 for Enable.
DCP Configuration

Test — Singleport Mode
The Test configuration options determine specifics, such as the duration of a test, for the various diagnostic tests available to the modem.
Table 4-13 shows each Test configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 2) Test Configuration Options — Singleport Mode
DTE Remote Loopback. Controls the use of Pin 21 of the EIA-232-D/CCITT V.24 interface by the DTE to initiate a remote loopback. An Abort command or test time-out ends this test.
Enable – The DTE forces the modem into remote loopback when the signal on Pin 21 (CCITT 140) is turned ON. Remote Loop ends when the signal is dropped.
Disable – The DTE does not initiate remote loopback in response to the signal on Pin 21.
The AT command is S-Register S51=n, where n is 0 for Disable and 1 for Enable.
DTE Local Loopback. Controls the use of Pin 18 of the EIA-232-D/CCITT V.24 interface by the DTE to initiate a local loopback. An Abort command or test time-out ends this test.
Enable – The DTE forces the modem into local loopback when the signal on Pin 18 (CCITT 141) is turned ON. Local loopback ends when the signal is dropped.
Disable – The DTE will not initiate local loopback in response to the signal on Pin 18.
The AT command is S-Register S52=n, where n is 0 for Disable and 1 for Enable.
Test Time-out. Determines how long a test runs before aborting.
Disable – Allows a test to run indefinitely.
30, 60, or 240 seconds – Allows the test to run for 30 seconds, 60 seconds, or 240 seconds.
The AT command is S-Register S18=n, where n is 0 for Disable and 1 to 255 seconds.
Receive Remote Loopback Response. Determines if the modem responds to a request for a remote loopback issued from a remote modem.
The AT command for Enable is &T4. The AT command for Disable is &T5.

(2 of 2) Test Configuration Options — Singleport Mode
V.54 Address. Determines which remote 392xPlus modem is placed into a remote loopback test. This test can be either a remote digital loopback or local analog loopback. This type of addressing should be used for extended data circuits (tail circuits).
Disable – This is used for normal point-to-point leased-line and dial networks.
Address Values – 01, 03, 05, 07, 09, 0B, 0D, 0F, 11, 13, 15, 17, 19, 1B, 1D, 1F, 25, 27, 2B, 2D, 2F, 33, 35, 37, 3B, 3D, 3F, 55, 57, 5B, 5F, 6F, 77, or 7F. This configuration option selects the address of a modem that is to be placed into a loopback test. This configuration option is used for more complex networks where multiple modems, used in extended data circuits (tail circuits), can be commanded to loopback.
The AT command for Disable is S-Register S53=0. The AT command for V.54 Address is S-Register S53=n, where n is a value from 1 to 34.
This configuration option only appears when V54 Address is enabled.
V.54 Device Type. Identifies where the modem is physically located in the network.
Peripheral – The modem is located at the endpoint of the network and is not connected back-to-back with another modem.
Intermediate – The modem is either of the two modems connected back-to-back.
The AT command for Peripheral is S-Register S54=0. The AT command for Intermediate is S-Register S54=1.
DCP Configuration

Misc — Singleport Mode
The Miscellaneous configuration options determine specifics for various functions, including network management parameters and remote modem access.
Table 4-14 shows each Misc (Miscellaneous) configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.
(1 of 3) Miscellaneous Configuration Options — Singleport Mode
Straps When Disconnected. Determines whether or not configuration options in the Active (Saved) configuration area are reloaded to Active (Operating) when a disconnect occurs. This is useful in modem pooling applications.
No Change – Configuration options do not change if a disconnect occurs.
Reload – The Active (Operating) configuration area, which controls modem operation, is reloaded from the Active (Saved) configuration area when a disconnect occurs. This is useful in modem pooling applications where it is desirable to start the modem from a known condition after every call. This allows multiple users to issue AT commands to change the modem’s operation for their particular call.
following commands are issued: AT&F0, AT&F1, AT&F2, AT&F3, AT&F4, AT&F5, AT&F6, AT&F7, AT&F8, AT&W0, AT&W1, AT&W2, and AT&Zn=x.
The AT command for the Straps When Disconnected configuration option is S-Register S88=n, where n is 0 or 231 for No_Change, and 1 or 232 for Reload.
Speaker Control. Determines if the speaker is OFF, ON until carrier signal is received by the modem, or ON all the time.
restore the modem to the Speaker Control and Speaker Volume configuration option settings.
The AT command for Off is M0 The AT command for On Until CD is M1. The AT command for On is M2.
Speaker Volume. Controls the level of speaker volume.
restore the modem to the Speaker Control and Speaker Volume configuration option settings.
The AT command for Low is L0 or L1. The AT command for Medium is L2. The AT command for High is L3.

(2 of 3) Miscellaneous Configuration Options — Singleport Mode
Access from Remote. Determines if your modem’s DCP can be accessed by a remote modem via the VF line.
Enable – Allows access from a remote modem.
Disable – Does not allow access from a remote modem.
The AT command is S-Register S55=n, where n is 0 for Enable and 1 for Disable.
Remote Access Password. Allows the entry of a password for establishing control of a remote modem from the DCP of a local modem. The same password must be used in both the local and remote modem.
The AT command equivalent is S-Registers S56=n, S57=x, S58=y, and S59=z, where n is the leftmost pair of digits, x is the second pair of digits, y is the third pair of digits, and z is the rightmost pair (or fourth) pair of digits. For example, if the remote access password is 12345678, then the value for S56 is 1 and 2, and the value for S59 is 7 and 8.
Directory Location 1 Callback. This configuration option controls whether or not the modem’s single number callback function is used.
Disable – Modem does not use the single number callback function.
Enable – Modem answers a call, disconnects, and dials the number stored in directory location 1.
The AT Command to Disable is S-Register S67=0. The AT Command to Enable is S-Register S67=1.
NMS Call Messages. Determines if the modem status and/or call summary information is sent to the NMS. The modem can itemize status, such as CallProgress messages, or it can report a summary of activity, such as Call Connect messages, to the NMS.
Call Connect & Progress – Enables both Call Connect and Call Progress information to be transmitted to the NMS.
Disable – Modem status and call summary information is not sent to the NMS.
Call Connect Only – The modem accumulates call statistics over a period of time and then transmits a summary of these statistics to the NMS. The NMS uses this data to produce utilization reports.
Call Progress Only – The modem transmits detailed modem status information to the NMS. These messages include any events that can display on the LCD.
The AT commands are S-Register S66=n where n is 0 for Call Connect & Progress, 1 for Disable, 2 for Call Connect Only, and 3 for Call Progress Only.
Modem – Selects the Diagnostic Channel.
NMS – Selects the Control Channel.
Disable – Prevents messages being sent from the diagnostic port.
DCP Configuration

(3 of 3) Miscellaneous Configuration Options — Singleport Mode
Network Position Identification. Each modem must be identified either as a control modem or a tributary modem.
For the Model 3920Plus, Tributary is the factory default. For the Model 3921Plus, Control is the factory default.
The AT command for Tributary is S74=0. The AT command for Control is S74=1.
This configuration option is not available in point-to-point tributaries, which are always set to address 01.
Network Management Address. Determines the address used when accessing a modem from the NMS or when using DCP functions that require network management addresses. Within a network link, a control modem can communicate with a tributary modem by using the tributary modem’s network management address. Each TMp tributary modem must have a different network management address. Address values range from 001 to 256.
This configuration option does not appear when the LeaseLine Rate is configured for TMp and the NetworkPosition is configured for Tributary.
Diagnostic Connection. Allows the configuration of the serial diagnostic port of the modem to be either a diagnostic channel that is connected to another modem (DC), or a control channel that is connected to a network management device (CC).
Modem (DC) – Selects the Diagnostic Channel.
NMS (CC) – Selects the Control Channel.
Disable – Prevents messages being sent from the diagnostic port.
The AT command is S-Register S90=n, where n is 0 for Disable and 1 for Enable.
Link Delay Seconds. Controls the length of time (in seconds) a modem will wait for responses from the downstream devices. This configuration option is used to calculate protocol timers for polling and normal selection.
Security — Singleport Mode
The Security configuration options allow you to set the parameters that control how a dial access security password is entered. For security configuration options, refer to Chapter 6, Dial Access Security.

Overview 5-1 Operating Modes 5-1 Switching Between Data Mode and Online Command Mode 5-1 Escape Sequence and Escape Guard Time 5-2 Command Guidelines 5-2 Result Codes 5-3 AT Command List 5-5 AT Command Format 5-5 S-Register List 5-15 S-Register Format 5-15
In Singleport mode, the AT command set provides an alternative method to the modem’s DCP for entering commands that control the operation and configuration of the 392xPlus modems. This chapter discusses guidelines necessary to operate AT commands as well as listing the modifiers for all AT commands supported by the 392xPlus modems. AT commands are issued from asynchronous DTEs.
The 392xPlus modems have two operating modes, Command mode and Data mode. Before a modem goes online (establishes a successful connection with a remote modem), it is considered to be in Command mode; an idle state where you can modify its operating parameters or issue modem commands. (Any command issued is acknowledged with a response in either words or digits known as Result Codes. Refer to Table 5-1 for a listing of result codes.)
Once the modems are online, either by answering or originating a call, they automatically switch to Data mode. Data mode is a state where any entries made from the DTE are considered data and are transmitted and received between modems. The modems remain in Data mode until the connection is broken or until they are forced into online Command mode using the escape sequence.
Sometimes it is necessary to change operating parameters while the modems are online. The Escape Sequence allows you to toggle the modem between Data mode and online Command mode while maintaining a connection with the remote modem. This is accomplished using the escape sequence ( + + + ) to exit Data mode and the O command to return to Data mode.

Escape Sequence and Escape Guard Time
The escape sequence is only issued when the modem is online and in Data mode. The 392xPlus modems use three consecutive plus ( + ) characters as the escape sequence. (To change this value, refer to S-Register S2 discussed later in Table 5-3 in the S-Register Format section.)
To prevent the modem from interpreting an embedded + + + in data as an escape sequence, the Escape Guard Time value determines the length of the pause before and after the escape sequence is issued. The 392xPlus modems use a one-second pause as the Escape Guard Time. (To change this value, refer to S-Register S12 discussed later in Table 5-3 in the S-Register Format section.)
To enter online Command mode while in Data mode, enter the following sequence:
Use the O command to return to Data mode from online Command mode. Enter the following command:
Review the following guidelines before using any AT Commands.
— 8 data bits + no parity + 1 stop bit.
— 7 data bits + no parity + 2 stop bits.
— 7 data bits + parity + 1 stop bit (parity can be odd, even, mark, or space).

AT Command Set and S-Registers
Table 5-1 lists all valid result codes for the 392xPlus modems.
Numbers
Numbers
(2) Word Description
(1)
0 0 OK Command executed
1 1 CONNECT Modem connected to line
2 2 RING Modem receiving a ring voltage from the VF line
3 3 NO CARRIER Modem lost carrier signal, does not detect carrier signal, or does not detect answer tone
4 4 ERROR Invalid command
5 5 CONNECT 1200* Connection at 1200 bps
6 6 NO DIALTONE* No dial tone detected
7 7 BUSY* Busy or trunk busy signal detected
8 8 NO ANSWER* No “quiet” answer (@)
10 10 CONNECT 2400* Connection at 2400 bps
11 11 CONNECT 4800* Connection at 4800 bps
12 12 CONNECT 9600* Connection at 9600 bps
13 16 CONNECT 12000* Connection at 12,000 bps
14 13 CONNECT 14400* Connection at 14,400 bps
15 14 CONNECT 19200* Connection at 19,200 bps
16 15 CONNECT 7200* Connection at 7200 bps
17 17 CONNECT 16800* Connection at 16,800 bps
19 19 CONNECT 300* Connection at 300 bps
20 10 CONNECT 2400/ EC**** Connection at 2400 bps with error control
21 11 CONNECT 4800/ EC**** Connection at 4800 bps with error control
* Only appears when the Extended Result Codes configuration option is enabled. ** Only appears when the Extended Result Codes configuration option is set for Use_DTE_Rate. This displays the DTE data rate instead of the line rate. *** Only appears when the Extended Result Codes configuration option is set for Add/EC. If this configuration option is set for Add/V42, MNP, then either V42b, V42, MNP5, MNP4, MNP3, MNP2, or NoEC appears. **** Only appears when the modulation is V.34 and the Extended Result Codes configuration option is set to Add/EC or Add/V.42. Receive Rate (RX) and Transmit Rate (TX) appear in place of the single rate.

Numbers
(1) Description Word Numbers
(2)
22 12 CONNECT 9600/ EC**** Connection at 9600 bps with error control
23 16 CONNECT 12000/ EC**** Connection at 12,000 bps with error control
24 13 CONNECT 14400/ EC**** Connection at 14,400 bps with error control
25 17 CONNECT 16800/ EC**** Connection at 16,800 bps with error control
26 15 CONNECT 7200/ EC**** Connection at 7200 bps with error control
27 5 CONNECT 1200/ EC*** Connection at 1200 bps with error control
28 28 CONNECT 38400** Connection at 38,400 bps
29 14 CONNECT 19200/ EC**** Connection at 19,200 bps with error control
30 30 CONNECT 57600** Connection at 57,600 bps
37 37 CONNECT 21600* Connection at 21,600 bps
38 38 CONNECT 24000* Connection at 24,000 bps
39 39 CONNECT 26400* Connection at 26,400 bps
40 40 CONNECT 28800* Connection at 28,800 bps
41 41 CONNECT 31200* Connection at 31,200 bps
42 42 CONNECT 33600* Connection at 33,600 bps
43 43 CONNECT 21600/ EC**** Connection at 21,600 bps with error control
44 44 CONNECT 24000/ EC**** Connection at 24,000 bps with error control
45 45 CONNECT 26400/ EC**** Connection at 26,400 bps with error control
46 46 CONNECT 28800/ EC**** Connection at 28,800 bps with error control
47 47 CONNECT 31200/ EC**** Connection at 31,200 bps with error control
48 48 CONNECT 33600/ EC**** Connection at 33,600 bps with error control
77 77 FORBIDDEN ⊗ Forbidden number
78 78 DELAYED ⊗ Delayed number
* Only appears when the Extended Result Codes configuration option is enabled. ** Only appears when the Extended Result Codes configuration option is set for Use_DTE_Rate. This displays the DTE data rate instead of the line rate. *** Only appears when the Extended Result Codes configuration option is set for Add/EC. If this configuration option is set for Add/V42, MNP, then either V42b, V42, MNP5, MNP4, MNP3, MNP2, or NoEC appears. **** Only appears when the modulation is V.34 and the Extended Result Codes configuration option is set to Add/EC or Add/V.42. Receive Rate (RX) and Transmit Rate (TX) appear in place of the single rate. ⊗Only appears in countries with specific dialing requirements.

AT Command Set and S-Registers
AT commands are issued from an asynchronous DTE, such as a PC, and control the modem’s operation and software configuration. AT commands are only applicable when the DTE Dialer Type configuration option is set for AT. (Refer to the &Mn and &Qn commands.)
Table 5-2 lists all AT commands supported by the 392xPlus modems. The first column lists the AT command. The second column defines and lists all possible values for that command. The Async Dial factory default is listed in bold. The third column lists the key sequence used to enter the equivalent DCP command. Use this to reference commands in Chapter 3 or Chapter 4 if further description is necessary.
AT commands are entered in Command mode using the following format:
Where: X is the AT command and n is the specific value for that command.
In Table 5-2, the value for X is listed in the AT Command column and the value for n is listed in the Description column.

DCP LCD Command
AT Command Description
Sequence
A/ Repeat Last Command. Reexecutes last command string. (Not to be preceded with AT or followed by pressing the Return key.)
A Answer Mode. Goes off-hook and attempts to establish a connection without waiting for a ring.
Dn Dial. Begins the dialing sequence. The dial string n (modifiers and telephone number) is entered after the D command.
Any digit 0–9, *, or # may be dialed as a DTMF tone. Only the digits 0–9 can be dialed in Pulse Dial mode. The following example shows how to dial through a PBX. The dial string consists of the command string and the telephone number:
Modifiers include the following parameters:
T — Tone (DTMF) dial. Any digit 0–9, *, or # can be dialed as tone.
P — Pulse dial. Only digits 0–9 can be dialed in Pulse Dial mode.
remain active until the end of that dial string. The modem defaults to the value set by the Dialer Type configuration option.
, — Pause. Causes the modem to pause before processing the next
character in the dial string. The length of this pause is determined by the setting of the Pause Time configuration option (refer to the Line Dialer configuration option group) or by value held in S-Register S8.
W — Wait for dial tone. The modem waits for a second dial tone before
processing the dial string. This can be the initial dial tone or can be used when dialing through a tandem PBX. For example, 9W 555-6789.
R — Reverse Dial mode. Causes the originating modem to send out
an answertone once it no longer detects ringback. (Ringback is the ring you hear at the originating site when making a call.) The R parameter must be the last character in the dial string. For correct operation, at least one ringback must be detected; therefore, the remote modem should be configured to answer on the second ring or subsequent rings.
@ — Quiet answer. Wait for five seconds of silence after dialing the
number. If the silence is not detected, the modem sends either a NO ANSWER result to the DTE.
! — Hook flash. This causes the modem to go on-hook for
0.5 seconds then return to off-hook.
; — Return to Command mode. Modem returns to Command mode
after dialing a number without disconnecting the call.
Space — Ignored by the dial string, can be included to enhance readability.
– — Ignored by the dial string, can be included to enhance readability.
+ — Ignored by the dial string, can be included to enhance readability.
( ) — Ignored by the dial string, can be included to enhance readability.
Call Setup\ Answer · None · None

AT Command Set and S-Registers
DCP LCD Command
AT Command
Sequence Description
DS=n Dial Stored Number. Dials the number stored in Location n (1–24). (To store a telephone number, refer to the &Zn=x command.)
Call Setup\Dial\ Dial Directory:
En Command Character Echo.
E0 Disables echo to the DTE. E1 Enables echo to the DTE.
Hn Hook Switch Control.
H0 Modem goes on-hook. H1 Modem goes off-hook.
In Identification.
I0 Displays product code — 144. 1 Displays 3-digit firmware revision number. I2 Performs an EPROM check.
Ln Speaker Volume.
L0 Selects low volume. L1 Selects low volume. L2 Selects medium volume. L3 Selects high volume.
Mn Speaker On/Off.
M0 Speaker always OFF. M1 Speaker ON until carrier signal is detected. M2 Speaker always ON.
O Return to Online or Data Mode. Returns modem to Data mode from Online Command mode.
P Pulse Dial. Sets the modem for Pulse Dial mode.
Qn Result Codes.
Q0 Enables modem to send result codes to the DTE. Q1 Disables modem from sending result codes to the DTE. Q2 Enables in Originate mode only for modem to send result codes to the DTE. Required for most UNIX applications.
Sn=r Change S-Register. Changes contents of S-Register (where n is the S-Register, and r is the new value).
Sn? Display S-Register. Displays value of S-Register where n is the S-Register number.
T Tone Dial. Sets the modem for tone dial mode. Configure\Edit\ Line Dialer
Vn Result Codes Format.
V0 Displays result codes in Number (1) format (digits). V1 Displays result codes as text. V2 Displays result codes in Number (2) format (digits).

DCP LCD Command
AT Command
Sequence Description
Xn Extended Result Code, Dial Tone Detect, and Busy Tone Detect Configuration Options.
Extended Dial Tone Busy Tone Result Code: Detect: Detect:
X0 Disable Disable Disable X1 Enable Disable Disable X2 Enable Enable Disable X3 Enable Disable Enable X4 Enable Enable Enable X5 Add/EC Enable Enable X6 Add/V42.MNP Enable Enable X7 Use DTE Rate Enable Enable
Extended Result Code:
Enable Displays all result codes listed in Table 5-1 except for error control suffix.
Disable Only displays OK, CONNECT, RING, NO CARRIER, ERROR
y p y , ERROR.
Add/EC Displays result codes with /EC suffix.
Add/V42,MNP Displays result codes with V.42 or MNP suffix.
Use DTE Rate Displays DTE data rate instead of line rate.
Dial Tone Detect:
E bl S t th d f di l t d t t Enable Sets the modem for dial tone detect. Disable Sets the modem for blind dialing.
Busy Tone Detect:
Enable Modem monitors for busy tone. Disable Modem ignores busy tone.
Yn Long Space Disconnect.
Y0 Disable. Ignores long space.
Y1 Enable. Disconnects if long space is detected. Enables transmission of a long space.
Zn Reset and Load Active.
Z0 Loads configuration options from Active (Saved) to Active (Operating).
Z1 Loads configuration options from Customer 1 to Active (Operating).
Z2 Loads configuration from Customer 2 to Active (Operating).
Z3 Loads configuration options from Active (Saved) to Active (Operating) and performs a reset.
Configure/Edit/ Line Dialer · Control\Reset

AT Command Set and S-Registers
DCP LCD Command
AT Command
Sequence Description
&Cn LSD Control.
&C0 Forced On. LSD ON at all times.
&C1 Standard RS232. LSD is ON when the remote modem’s carrier signal is detected. LSD is OFF when carrier signal is not detected.
&C2 Wink When Disconnect. LSD normally forced ON, turns OFF for approximately one second upon disconnecting.
&C3 Follows DTR. State of LSD follows state of DTR.
&C4 Simulated Control Carrier. State of LSD follows state of remote modem’s RTS.
&C5 =DTR/Disconnect Off. State of LSD follows state of DTR except upon a disconnect where DTR remains ON and LSD turns OFF. DTR must then toggle OFF and ON to turn LSD ON. Use this setting for AT&T DATAKIT applications. Note that to use this option, the DTR Action configuration option must be set to Stndrd_RS232 (&D1, &D2, or &D3).
&Dn DTR Action.
&D0 Ignore. Modem ignores the true status of DTR and treats it as always ON.
Standard RS232. DTR Signal is controlled by the DTE.
&D4 Controls On-Hook. Modem does not disconnect from the VF line until DTR turns OFF.
&D5 Controls Transmitter Mute. Mutes the transmitter whenever DTR drops on the DTE interface. This can be used on the answer side modem to force the originate modem to initiate a dial backup.
&Fn Select Factory Default Configuration Options. Loads factory configuration options into Active (Operating) area.
&F0 Async Dial &F1 Sync Dial &F2 Sync Leased: Answer &F3 UNIX Dial &F4 Sync Leased: Originate &F5 Async Leased: Answer &F6 Async Leased: Originate &F7 TMp: Control &F8 TMp: Trib
Only the &F0 and &F3 commands will leave you in AT Command mode. The other commands will take you out of AT command control and place the modem into Dumb mode. The only way to return to AT command control is via the diagnostic control panel (DCP). For additional information, refer to Appendix F, Default Configuration Options.
Configure\Edit\ DTE Interface · Configure\Edit\ DTE Interface · Configure/Factory

DCP LCD Command
AT Command
Sequence Description
&Gn V.22bis Guard Tone.
&G0 Disable. &G1 550 Hz. &G2 1800 Hz.
&In Dial Transmit Level.
This command is disabled in some countries (it answers OK but does not change the level).
&Ln Leased Mode.
&L0 Disables leased-line operation. &L1 2-wire originate leased-line operation. &L2 4-wire originate leased-line operation. &L3 2-wire answer leased-line operation. &L4 4-wire answer leased-line operation.
The &L command will cause the modem to reset before entering or exiting Leased Line mode. Therefore, it must be entered as the last command in an initialization string.
Configure\Edit\ Dial Line · Configure\Edit\ Dial Line · Configure\Edit\ Leased Line

AT Command Set and S-Registers
DCP LCD Command
AT Command
Sequence Description
Async/Sync Mode and DTE Dialer Type.
&M0, &Q0 Modem operates in Asynchronous mode using AT Command protocol.
&M1, &Q1 Modem operates in Synchronous mode using AT Command protocol.
&M2, &Q2 Modem operates in Synchronous mode and dials telephone number stored in directory location 1 when DTR signal turns OFF and then ON.
&M3, &Q3 Modem operates in Synchronous mode using AT Command protocol.
&M231 Modem operates in Asynchronous mode using no AT Command protocol.
&M232 Modem operates in Asynchronous mode using V.25bis asynchronous AT Command protocol.
&M233 Modem operates in Synchronous mode using V.25bis bisynchronous AT Command protocol.
&M234 Modem operates in Synchronous mode using V.25bis HDLC AT Command protocol.
&M235 Modem operates in Asynchronous mode using AT&T Emulation AT Command protocol.
&M236 Modem operates in Synchronous mode using no AT Command protocol.
The following commands disable the use of AT commands and force the modem into Dumb mode: &M2, &Q2, &M231, &M232, &M233, &M234, &M235, &M236.
&Rn RTS Action.
&R0 Standard RS232. &R1 Ignores RTS. &R2 Simulated Control Carrier. &R3 Control Carrier.
&Sn DSR Control.
&S0 Forced On. &S1 Standard RS232. &S2 Wink When Disconnect. &S3 Follows DTR. &S4 On Early. &S5 Delay to Data.

DCP LCD Command
AT Command
Sequence Description
&Tn Tests.
&T0 Abort. Stops any test in progress. &T1 Local Analog Loop. &T2 Pattern. Transmits and receives a 511 Bit Error Rate Test (BERT). &T3 Local Digital Loopback test. &T4 Enables Receive Remote Loopback Response configuration option. &T5 Disables Receive Remote Loopback Response configuration option. &T6 Remote Digital Loopback test. &T7 Remote Digital Loopback with Pattern. &T8 Local Loopback with Pattern. &T9 Self-Test.
&Vn View Configuration Options. Displays each configuration group within the Active (Operating), Active (Saved), Customer 1, and Customer 2 configuration areas as well as the telephone numbers stores in directory locations 1–24.
&V0 Active (Operating) configuration options. &V1 Active (Saved) configuration options. &V2 Customer 1 configuration options. &V3 Customer 2 configuration options. &V4 Directory locations 1–24.
&Wn Write (Save to Memory). Saves the current configuration options in Active (Operating) to one of three configuration areas:
&W0 Saved to Active(Save). &W1 Saved to Customer 1. &W2 Saved to Customer 2.
&Xn Transmit Clock Source.
&X0 Internal. Modem provides transmit clock source for synchronous data (Pin 15). &X1 External. Modem derives external transmit clock source provided on Pin 24 for synchronous data. &X2 Receive Clock Loop. Modem derives transmit clock source from receive signal for synchronous data (Pin 17).

AT Command Set and S-Registers
DCP LCD Command
AT Command
Sequence Description
&Zn=x Store Telephone Numbers. Modem saves the telephone numbers and dial command modifiers (if any) entered for x (up to 40 characters in length) in Directory Location n (1–24). For example, the command AT&Z1 = 5551234 stores the telephone number 555-1234 into directory location 1.
Call Setup\ Change Directory
To clear a telephone number from a memory location, issue the &Zn=x command without entering a telephone number.
\An Maximum Frame Size.
\A0 64 bytes. \A1 128 bytes. \A2 192 bytes. \A3 256 bytes. \A4 32 bytes. \A5 16 bytes.
\Cn Error Control Negotiate Buffer.
\C0 Disable. \C1 Enable. \C2 Disables and switches modem to Buffer mode.
\Dn CTS Control.
\D0 Forced On. Forces CTS to always ON. \D1 Standard RS232. \D2 Wink When Disconnect. CTS is turned OFF for 1 to 2 seconds upon a disconnect. \D3 Follows DTR. The state of CTS follows the state of DTR. \D4 Follows RTS. The state of CTS follows the state of RTS.
\Gn Modem to Modem Flow Control.
\G0 Disable. \G1 Enable.
\Kn Buffer Control, Send Break Control, Break Forces Escape.
Break Buffer Send Break Break Forces Control: Control: Escape:
\K0 Discard Data Break First Enable \K1 Discard Data Break First Disable \K2 Keep Data Break First Enable \K3 Keep Data Break First Disable \K4 Keep Data Data First Enable \K5 Keep Data Data First Disable

DCP LCD Command
AT Command
Sequence Description
\Nn Error Control Mode.
\N0 Buffer Mode. \N1 Direct Mode. \N2 MNP or Disconnect. \N3 MNP or Buffer. \N4 V.42/MNP or Disconnect. \N5 V.42/MNP or Buffer. \N6 LAPM or Disconnect. \N7 LAPM or Buffer.
\Qn Flow Control of DTE, Flow Control of Modem.
Flow Control Flow Control of DTE: of Modem:
\Q0 Disable Disable \Q1 XON/XOFF XON/XOFF \Q2 CTS to DTE Disable \Q3 CTS to DTE RTS to Mdm \Q4 XON/XOFF Disable \Q5 Disable XON/XOFF \Q6 Disable RTS to Mdm
\Tn No Data Disconnect Timer.
\T0 Disable. \Tn Where n is a value from 1 to 255 in 1-minute increments.
\Xn XON/XOFF Passthrough Flow Control.
\X0 Disable. \X1 Enable.
%An Error Control Fallback Character.
%An Where n is an ASCII value from 0 to 127. Factory default is 013 ASCII.
%Cn MNP5 Data Compression.
%C0 Disable. %C1 Enable.
Hn V.42bis Compression.
H0 Disable. H1 Enable (Transmit (TX) only). H2 Enable (Receive (RX) only). H3 Enable (Transmit (TX) and Receive (RX)).

AT Command Set and S-Registers
S-Registers affect the operating parameters of the 392xPlus modems. S-Registers are only applicable when the DTE Dialer Type configuration option is set for AT. (Refer to the &Mn and &Qn commands.)
Table 5-3 lists all S-Registers supported by the 392xPlus modems. The first column lists the S-Register. The second column lists all possible values for that register. The third column lists the key sequence used to enter the equivalent from the DCP. Use this column to reference commands in Chapter 4 if further description is necessary.
In some countries, the range of allowable values of some S-Registers are restricted. If the DTE attempts to enter an illegal value, the modem will answer OK, but it will set the register to the closest legal value. The DTE can check the actual value of the register with Sn? command.
S-Registers can be displayed and/or modified when the modem is in Command mode. To display the value of an S-Register, issue the following command:
TYPE: ATSn?
Where: n is the register number.
To modify the value of an S-Register, issue the following command:
Where: n is the register number, and r is the new value.
In Table 5-3, the value for n is listed in the S-Register column, and the value for r is listed in the Description column.

DCP LCD Command
S-Register Description
Sequence
S0 Auto-Answer Ring Number1. Register determines number of rings the modem will count before automatically answering a call.
Enter zero (0) if you do not want the modem to automatically answer any calls. Otherwise, enter a value from 1–255 for the number of rings to count before answering. The factory setting is 1.
S2 AT Escape Character. Register determines ASCII value used for escape sequence to enter Command mode from Data mode.
Enter a value from 0 to 127 for the escape character. Any value greater than 127 causes the modem to disable the escape sequence. When the escape sequence is disabled, the modem cannot return to Command mode until the call is disconnected. The factory setting is 43 (+ key).
S3 Carriage Return Character. Register determines ASCII value used as the carriage return (Return key). This character is used to end command lines and result codes.
Enter a value from 0 to 127 for the command end character. The factory setting is 13 (carriage return key).
S4 Line Feed Character. Register determines ASCII value used as the line feed character.
Enter a value from 0–127 for the line feed character. The factory setting is 10 (ASCII carriage return or line feed).
S5 Backspace Character. Register determines ASCII value used as the backspace (Backspace key). This character moves the cursor to the left and erases the previous character.
Enter a value from 0–127. The factory setting is 8 (backspace key).
S6 Blind Dial Pause1. Register determines how long (in seconds) the modem waits after going off-hook before dialing a telephone number if using result code X0, X1, or X3.
Enter a value from 2–255 seconds. The factory setting is 2.
S7 No Answer Time-out1. Register determines how long (in seconds) an originating modem waits before abandoning a call when no answer tone is received.
Enter a value from 1–255 seconds. The factory setting is 45.
S8 “,” Pause Time for the Dial Modifier. Register determines how long (in seconds) the modem pauses when it encounters a comma (,) in the Dial command string.
Enter a value from 0–255 seconds. The factory setting is 2.
S10 No Carrier Disconnect1. Register determines how long (in tenths of seconds) the modem allows the carrier signal to be OFF before disconnecting the call.
Enter a value from 0–254 in 0.1 second increments. A value of 255 disables this register. The factory setting is 20 (2 seconds).
1 The range of allowable values may be restricted in some countries.

AT Command Set and S-Registers
DCP LCD Command
S-Register
Sequence Description
S12 Escape Guard Time. Register sets the value (in 20-millisecond increments) for the required pause before and after the escape sequence is issued. The guard time prevents the modem from interpreting data as the escape sequence characters.
Enter a value from 0–255 in 20-millisecond increments. The factory setting of 50 equals 1000 milliseconds or one second.
S14 Asymmetric Rate Mode. Register determines whether VF rates for transmitting and receiving are identical when using V.34 modulation on a dial line. The factory setting is Enable.
S15 Asymmetric Rate Mode. Register determines whether VF rates for transmitting and receiving are identical when using V.34 modulation on a leased line. The factory setting is Enable.
S18 Test Time-out. Register sets the duration (in seconds) for the modem tests. This automatically cancels any test in progress after the time of this register expires. Any test can be manually canceled by issuing the escape sequence (+++) followed by the &T0 command.
Enter a value from 0–255 seconds. A value of 0 disables this register. The factory setting is Disable (0).
S26 RTS-to-CTS Delay. Register sets the length of time (in 10-millisecond increments) the modem waits after receiving RTS before issuing CTS to the DTE.
Enter a value from 0–255. The factory setting is 0.
S40 Auto Make Busy. Register determines if the modem goes off-hook under certain conditions. This register should only be enabled when the modem is located behind a user’s Private Branch Exchange (PBX). This register is only valid for Model 3921Plus modems.
Register has the following values:
0 = Disable 1 = Enable
The factory setting is Disable.

DCP LCD Command
S-Register
Sequence Description
S41 Dial-Line Rate. Register determines the modem’s data rate and modulation scheme for operation on dial lines.
Register has the following values:
1 = 14,400 (V.32bis) 2 = 12,000(V.32bis) 3 = 9600 (V.32bis) 4 = 7200 (V.32bis) 5 = 4800 (V.32bis) 6 = 2400 (V.22bis) 7 = 1200 (V.22) 8 = 1200 (212A) 10 = 0–300 (V.21) 11 = 0–300 (103J) 12 = 1200/75 (V.23) 13 = 75/1200 (V.23) 18 = 600/75 (V.23) 19 = 75/600 (V.23) 20 = 19,200 (V.32 terbo) 21 = 16,800 (V.32 terbo) 22 = 33,600 23 = 31,200 24 = 28,800 (V.34) 25 = 26,400 (V.34) 26 = 24,000 (V.34) 27 = 21,600 (V.34) 28 = 19,200 (V.34) 29 = 16,800 (V.34) 30 = 14,400 (V.34) 31 = 12,000 (V.34) 32 = 9600 (V.34) 33 = 7200 (V.34) 34 = 4800 (V.34) 35 = 2400 (V.34)
The factory setting is 28,800 (V.34).
S43 V.32bis Train. Register controls the modem’s train time for V.32bis/V.32 mode.
Register has the following values:
0 = Long 1 = Short
The factory setting is Long.
Configure\Edit\ Dial Line · Configure\Edit\ Dial Line

AT Command Set and S-Registers
DCP LCD Command
S-Register
Sequence Description
S44 Leased-Line Rate. Register determines the modem’s data rate and modulation scheme for operation on either 2-wire or 4-wire leased lines in either Answer or Originate mode.
Register has the following values:
1 = 14,400 (V.32bis) 2 = 12,000 (V.32bis) 3 = 9600 (V.32) 4 = 7200 (V.32bis) 5 = 4800(V.32) 6 = 2400 (V.22bis) 11 = 14,400 (V.33) 12 = 12,000 (V.33) 13 = 9600 (V.29) 14 = 7200 (V.29) 15 = 4800 (V.29) 16 = 4800 (V.27bis) 17 = 2400 (V.27bis) 18 = 19,200 (V.32 terbo) 19 = 16,800 (V.32 terbo) 20 = 19,200 (TMp) 21 = 14,400 (TMp) 22 = 9600 (TMp) 23 = 7200 (TMp) 24 = 4800 (TMp) 25 = 2400 (TMp) 26 = 33,600 27 = 31,200 28 = 28,800 (V.34) 29 = 26,400 (V.34) 30 = 24,000 (V.34) 31 = 21,600 (V.34) 32 = 19,200 (V.34) 33 = 16,800 (V.34) 34 = 14,400 (V.34) 35 = 12,000 (V.34) 36 = 9600 (V.34) 37 = 7200 (V.34) 38 = 4800 (V.34) 39 = 2400 (V.34)
The factory setting is 28,800 (V.34).
S45 Leased TX Level2. Register determines the modem’s transmit power output level over leased lines.
Enter a value from 0 to –15 dBm. The factory setting is 0 dBm.
2 The range of allowable values is 0 through 15 in North America, and 1 through 15 in other countries. The default is country dependent.
Configure\Edit\ Leased Line · Configure\Edit\ Leased Line

DCP LCD Command
S-Register
Sequence Description
S46 Auto Dial Backup. Register determines if the modem performs an automatic dial backup if the leased lines fail.
Register has the following values:
0 = Disable 1 = Enable
The factory setting is Disable.
S47 Auto Dial Standby. Register determines if the modem performs an automatic dial standby if in Dial Backup mode.
Register has the following values:
0 = Disable 1 = 15 minutes 2 = 1 hour 3 = 4 hours 4 = Test(2min) 5 = Adv 15min 6 = Adv 30min 7 = Adv 1 hr 8 = Adv2minTest
The factory setting is Disable.
S48 Leased-Line Carrier On Level. Register determines if the modem disconnects if the carrier signal on leased lines falls below –26 dBm or –43 dBm.
Register has the following values:
0 = –43 dBm 1 = –26 dBm 2 = –33 dBm
The factory setting is country dependent (usually –43 dBm). In France, the factory setting is –26 dBm in 4-wire operation and –33 dBm in 2-wire operation.
S49 Buffer Disconnect Delay. Register determines how long the modem continues to transmit data stored in its buffers when the modem is commanded to disconnect by a locally attached DTE.
Enter a value from 0–255 seconds. (A value of 0 disables this register.) The factory setting is 10 seconds.
S51 DTE RL (CT140). Register determines if the modem performs a remote digital loopback if it receives a CT140 signal from the DTE.
Register has the following values:
0 = Disable 1 = Enable
The factory setting is Disable.

AT Command Set and S-Registers
DCP LCD Command
S-Register
Sequence Description
S52 DTE LL (CT141). Register determines if the modem performs a local analog loopback if it receives a CT141 signal from the DTE.
Register has the following values:
0 = Disable 1 = Enable
The factory setting is Disable.
S53 V.54 Address. Identifies the address of the modem to be placed in a loopback test.
Register has the following values:
0 = Disable 1–34 = Modem address
The factory setting is Disable.
S54 V.54 Device Type. Identifies where the modem is physically located in the network.
Register has the following values:
0 = Peripheral 1 = Intermediate
The factory setting is Peripheral.
S55 Access From Remote. Register determines if a modem’s DCP can be accessed by a remote modem.
Register has the following values:
0 = Enable 1 = Disable
The factory setting is Enable.
S56 Remote Access Password. Register allows entry of the first pair (leftmost) of digits of a remote access password. Any value from 00 to 99 is valid. For example, if the remote access password is 12345678, then S56 = 1 and 2.
S57 Remote Access Password. Register allows entry of the second pair of digits of a remote access password. Any value from 00 to 99 is valid.
S58 Remote Access Password. Register allows entry of the third pair of digits of a remote access password. Any value from 00 to 99 is valid.
S59 Remote Access Password. Register allows entry of the fourth pair (rightmost) of digits of a remote access password. Any value from 00 to 99 is valid.

DCP LCD Command
S-Register
Sequence Description
S61 CT111 Rate Control. Register determines if CT111 Rate is disabled, set for Fallback 1 or Fallback 2.
CT111 Rate allows the DTE to control modem rate via Pin 23 of the EIA-232-D interface. This configuration option determines the effect of the DTE Rate Control signal. It is only valid in Async Direct mode and Synchronous mode. For proper operation, disable the V.32bis Autorate and V.32bis Automode configuration options.
Register has the following values:
0 = Disable 1 = Fallback 2 = Fallback 2
The factory setting is Disable.
S62 V.25bis Coding. Register identifies to the modem the type of coding used by the DTE while in V.25bis mode.
Register has the following values:
The factory setting is ASCII.
S63 V.25bis Idle Character. Register identifies to the modem the type of idle fill used by the DTE while in V.25bis mode.
Register has the following values:
0 = Mark 1 = Flag
The factory setting is Mark.
S64 V.25bis New Line Character. Register identifies to the modem the type of line terminator used by the DTE while in V.25bis mode.
Register has the following values:
0 = Carriage Return and Line Feed 1 = Carriage Return 2 = Line Feed
The factory setting is carriage return and line feed (CR + LF).
S65 Line Current Disconnect. Register determines if the modem disconnects if an 8-millisecond or 90-millisecond interruption in loop current occurs.
Register has the following values:
0 = Enable (8msec) 1 = Enable (90msec) 2 = Disable
The factory setting is Enable (8msec).

AT Command Set and S-Registers
DCP LCD Command
S-Register
Sequence Description
S66 NMS Call Messages. Register determines if the modem sends information regarding status (Call Progress) and/or sends summarized call statistics (Call Connect) to the 6700 Series Network Management System (NMS).
Register has the following values:
0 = Call Connect & Progress 1 = Disable 2 = Call Connect Only 3 = Call Progress Only
The factory setting is Call Connect & Progress.
S67 Directory Location 1 Callback. Register determines if the modem uses the single number callback function.
Register has the following values:
0 = Disable 1 = Enable
The factory setting is Disable.
S69 Make Busy Via DTR. Register determines if the modem goes off-hook (busy) when DTR is OFF.
Register has the following values:
0 = Disable 1 = Enable
The factory setting is Disable.
S70 V.27bis Train. Register controls the train time for V.27bis operation.
Register has the following values:
0 = Short 1 = Long
The factory setting is Short.
S71 XTXC Clamps TXC. Register allows the modem’s TXC output to be clamped off when TX Clock Source is configured for External.
Register has the following values:
0 = Enable 1 = Disable
The factory setting is Enable.
S72 RTS Antistreaming. Register determines the antistreaming operation of the modem.
Register has the following values:
0 = Disable 1 = 10 sec 2 = 30 sec 3 = 1 min 4 = 2 min 5 = 3 min 6 = 5 min
The factory setting is Disable.

DCP LCD Command
S-Register
Sequence Description
S74 Network Position Identification. Register identifies each modem as either a control or tributary modem.
Register has the following values:
0 = Tributary 1 = Control
The factory setting is Tributary.
S75 Network Management Address. Register determines the modem’s network address. This address is used when accessing the modem from the 6700 Series NMS.
Enter a value from 0 (network address 001) to 255 (network address 256). The factory setting is 0.
S76 V.32bis Autorate (Dial Line). Register determines if Autorating is used on dial lines when connected in V.32bis mode.
Register has the following values:
0 = Enable 1 = Disable
The factory setting is Enable.
S78 V.32bis Automode (Dial Line). Register allows the modem (when operating on dial lines) to automatically detect and connect to the remote modem’s modulation scheme.
Register has the following values:
0 = Enable 1 = Disable
The factory setting is Enable.
S82 V.32bis Autorate (Leased Line). Register determines if Autorating is used on leased lines when connected in V.32bis mode.
Register has the following values:
0 = Enable 1 = Disable
The factory setting is Enable.
S84 AT Command Mode. Register determines how the modem responds to valid and invalid AT commands.
Register has the following values:
0 = Normal 1 = No ERROR 2 = No Strap or ERROR
The factory setting is Normal.

AT Command Set and S-Registers
DCP LCD Command
S-Register
Sequence Description
S85 Fast Disconnect. Register allows the modem to disconnect immediately after receiving a disconnect command from a local DTE or its own diagnostic control panel.
Register has the following values:
0 = Disable 1 = Enable
The factory setting is Disable.
S88 Straps When Disconnected. Register determines whether or not configuration options in the Active (Saved) configuration area are reloaded to Active (Operating) when a disconnect occurs.
Register has the following values:
0 or 231 = No Change 1 or 232 = Reload
The factory setting is No Change.
S89 V.42 Automatic Request for Retransmission (ARQ) Window Size Increase. Register allows the ARQ window size to be set to a value from six frames to fifteen frames.
For best performance, this register should remain at its default setting of six frames (ATS89 = 0). The only reason to change it is for satellite delays.
Register has the following values:
0 = six frames 1 = seven frames 2 = eight frames 3 = nine frames 4 = ten frames 5 = eleven frames 6 = twelve frames 7 = thirteen frames 8 = fourteen frames 9 = fifteen frames
The factory setting is 0 (six frames).
This command only applies when the modem connects using V.42bis data compression or V.42 error control. If the modem is configured for Direct mode, MNP mode, Buffer mode, or Synchronous operation, this command is ignored.
This command does not have a front panel equivalent.
S90 DTE Rate = VF. Register allows the DTE’s data rate to be equal to the VF (telephone line) data rate. If Enabled, the data rate between the DTE and modem is the same as the modem’s VF data rate. As a result, when the modem is in Data mode, the speed of the data passed between the modem and DTE occurs at the VF data rate.
Register has the following values:
0 = Disable 1 = Enable
The factory setting is Disable.
Configure\Edit\ Line Dialer · Configure\Edit\ Misc · Configure\Edit\ DTE Interface

DCP LCD Command
S-Register
Sequence Description
S91 Cellular Enhancement. Register allows the modem to use non-standard techniques to enhance V.42 operation for cellular applications. It is still compatible, however, with modems which do not have the cellular enhancement implemented or enabled.
Register has the following values:
0 = Disable 1 = Enable
The factory setting is Disable.
S92 V.29 Train On Data. When enabled, the modem receiver can train based upon the incoming data or a training sequence from the distant modem. This function is necessary for a remote (tributary) modem in a V.29 multipoint network and is recommended for a control modem as well.
Register has the following values:
0 = Disable 1 = Enable
The factory setting is Disable.
S93 V.29 Retrain. When enabled, the modem transmits a training sequence whenever it receives one. This configuration option should normally be disabled for control modems.
Register has the following values:
0 = Enable 1 = Disable
The factory setting is Enable.
S94 V29 Link Configuration. Selects point-to-point or multipoint operation.
Register has the following values:
0 = PointToPoint 1 = Multipoint
The factory setting is PointToPoint.
S95 Trellis Multipoint (TMp) Train Time. Defines the length of time energy is sent from the tributary modem to the control modem. More severe line conditions require longer time selections.
Register has the following values:
0 = 10 milliseconds 1 = 20 milliseconds 2 = 50 milliseconds 3 = 100 milliseconds 4 = 200 milliseconds 5 = 300 milliseconds
The factory setting is 0 (10 milliseconds).

AT Command Set and S-Registers
DCP LCD Command
S-Register
Sequence Description
S96 Trellis Multipoint (TMp) Tx Preemphasis. Provides amplification for frequencies above the carrier frequency to compensate for high frequency line attenuation.
Register has the following values:
0 = Enable 1 = Disable
The factory setting is Enable.
S97 Reduced Asynchronous Buffer Size. Register limits the modem’s buffer size to a maximum of 20 characters.
Register has the following values:
0 = Disable 1 = Enable
The factory setting is Disable.
S98 Special Standby. Supports automatic dial standby when a third modem is used for dial backup.
Register has the following values:
0 = Disable 1 = Enable
The factory setting is Disable.
Configure\Edit\ Leased · Configure\Edit\ V42/MNP/Buffer · Configure\Edit\ Leased

Chapter 6, Dial Access Security, is not available for viewing online because it contains security-sensitive information. Dial Access Security information is available in the COMSPHERE 392xPlus Modems Models 3920Plus and 3921Plus Installation and Operation Manual, Document No. 3920-A2-GN31-30.
To order product documentation contact your sales representative.

Menu Tree
Overview A-1
Pages A-2 and A-3 provide a menu tree for the 392xPlus modems.
A-1 3920-A2-GN31-30 November 1996

Displays current status of modem along with data rate and error control mode. “Status”

Major Minor Status Dial Thresh Security Port1 Port2 Port3 Port4
Ser# Mod# FRev HPt# FPt# Country LSD DTR DSR Tst TXD RXD RTS CTS
Line = Pri 4W APL Line = Pri 2W APL Line = Bkup 2W APL Line = Dial Backup Line = Dial ONLY Line = No Sync
SigQual RcvLevel Sig/Noise NrEchLvl FarEchLv FarEchDel EchoFreqOff Phase Hts Impul Hts DropOuts Retrains Phas Jtr NonLinear FreqOffset Gain Hts
Rate* Async EIA
*Not shown when the Digital Bridge configuration option is enabled.
A-2 November 1996 3920-A2-GN31-30

(Singleport mode only)
Control SubHS Call_Setup Tlk/Data Remote
Choose Address (TMp Control only)
Choose Password
(TMp only)
Directory Locations 1 – 24
(Not in TMp Trib)
Secondary Prim (data blckd)
(ExitRem appears instead of Remote when using Remote mode)
or DiscServiceLine Does not appear in TMp Control mode.
Does not appear in Remote mode. (Self, Loc_Digital_Loop, and Pattern appear if the secondary channel is used. Rem_Digital_Loop does not appear in TMp mode.)
A-3 3920-A2-GN31-30 November 1996

Troubleshooting
Overview B-1
This appendix points out basic problems that can occur when operating a 392xPlus modem. Use Tables B-1 through B-6 to check out these problems. If you are having data communication difficulties, such as periodic character loss, random errors, or constant format errors, use the loopback tests described in the Test section of Chapter 4. With these tests you can usually isolate the fault in your system by using the process of elimination. If problems continue to occur, contact your service representative.
Symptom Action
The modem did not pass the power-up self-test.
Contact your service representative.
The power LED does not light or the LCD does not display information.
Make sure the modem’s ON/OFF switch is in the ON position.
Make sure the power supply is connected to the dc power receptacle on the modem.
If the Power LED and/or LCD do not operate, contact your service representative.
A problem is suspected after the power-up self-test.
Perform a self-test via the modem’s DCP or type AT&T9 if using AT commands.
Perform a local analog loopback with a Pattern test. If the modem consistently registers errors, contact your service representative.
If the modem passes the above tests and a problem still exists, then the problem is probably not with your modem.
B-1 3920-A2-GN31-30 November 1996

Symptom Action
The modems do not train-up on leased lines.
Verify that the correct cabling is used for your application. Refer to Chapter 2, Modem Installation.
Verify that one modem is configured for Answer mode and the other is configured for Originate mode. (For TMp operation one modem must be configured as a control modem and the other as a tributary modem.)
Verify that both modems are using the same modulation scheme.
Verify that both modems are configured for the appropriate leased-line mode. For example, if you have a 4-wire leased line, then the modems must be configured for 4-wire operation.
Symptom Action
The dial backup line is present, but the modems cannot connect.
Verify that the correct telephone number for the remote modem is stored in directory location 1.
Verify that both modems have the Auto Dial Backup configuration option set to Enable. Refer to Leased Line in Chapter 4.
Call the answering modem with a handset and verify that the modem’s answer tone is transmitted.
The modem does not switch back to leased-line operation.
Verify that the Auto Dial Standby configuration option is enabled. Refer to Leased Line in Chapter 4.
B-2 November 1996 3920-A2-GN31-30

Symptom Action
The modem does not accept or echo back AT commands.
Verify that the cable between the Async port of the DTE and the modem is a standard RS-232 cable. (Null modem cables, also known as crossover cables, do not work in this application.)
Verify that the Command Character Echo configuration option is enabled. Refer to DTE Dialer in Chapter 4.
Verify that the DTE Dialer Type configuration option is set to AT. Refer to DTE Dialer in Chapter 4.
Verify that the Result Codes configuration option is enabled. Refer to DTE Dialer in Chapter 4.
Reload the Async Dial factory configuration area to guarantee that all configuration options are returned to their proper setting.
Make sure that all AT commands are terminated with a carriage return.
Verify that the Carriage Return Character configuration option matches what is used by the DTE. Refer to DTE Dialer in Chapter 4.
Verify that the DTE has a valid character format. Valid format consists of 8 data bits with no parity or 7 data bits with even, odd, mark or space parity.
Verify that the DTE’s data rate is supported by the modem. Refer to the Async DTE Rate configuration option in the DTE Interface section of Chapter 4.
If using a PC, verify that the modem is attached to the correct communications port.
B-3 3920-A2-GN31-30 November 1996
Troubleshooting

(1 of 2) Modem — VF Connection
Symptom Action
The modem does not receive a dial tone.
Attach a telephone directly to the telephone line to verify that a dial tone exists.
Make sure the VF line is connected to the modem’s rear jack labeled DIAL.
The modem does not go off-hook and answer an incoming call.
Verify that the Auto Answer Ring Count configuration option is set to a value other than 0 (disable). Refer to Line Dialer in Chapter 4.
Verify that the DTE is providing DTR to the modem.
If the DTE does not provide DTR to the modem, verify that the modem’s DTR Action configuration option is set for Ignore. Refer to DTE Interface in Chapter 4.
Verify that all cables are attached to the correct connectors on the rear of the modem.
The modem goes off-hook, answers, but does not connect.
Perform a Local Analog Loopback test and verify that data entered at the DTE is echoed back to the DTE.
Verify that the originating modem is compatible with your receiving modem.
Verify that the originating modem recognizes your modem’s answer tone.
Verify that the originating modem supports your modem’s modulation schemes. The 392xPlus modem recognizes CCITT V.34, V.32bis, V.32, V.22bis, V.22, V.21, Bell 212A, and Bell 103J. The 392xPlus modem does not support other vendors’ proprietary modulation schemes.
Force your modem to operate at the same modulation scheme as the originating modem to see if they connect.
The Originate Mode does not function properly.
Verify that the modem’s DTE Dialer Type configuration option is set to the correct setting: either AT, DTR Dialing, V.25bis Async, V.25bis Bisync, or V.25bis HDLC. Refer to DTE Dialer in Chapter 4.
The modem does not go off-hook and begin dialing.
If using AT Dialing, refer to Table B-4, Modem — DTE Connection.
If using DTR Dialing, verify the telephone number stored in directory location 1, and verify that the DTE is raising DTR from Off to ON to initiate a dial.
If using V.25bis Async, verify that the correct character format is set to 7 data bits with even parity and 1 stop bit, and the carriage return and line feed are used as command terminators.
If using V.25bis Bisync, verify that the correct character format uses two synchronous control characters and a start-of-text control character before the text block, and an end-of-text control character after the text block.
If using V.25bis HDLC, verify that the character format uses flag, address, and control characters before the text block and a frame sequence check and flag after the text block.
The modem dials but does not connect.
If the modem is operating behind a PBX, determine if a 9 and comma are needed before the telephone number.
Verify whether Tone or Pulse dialing is needed.
Verify that both modems are configured the same in regard to Error Control. Try calling in Buffer mode.
If both modems use V.32bis or V.32 modulation, try setting the modem’s V.32bis Train configuration option to Long.
B-4 November 1996 3920-A2-GN31-30

(2 of 2) Modem — VF Connection
Symptom Action
Intermittent disconnects, high error rates, or excessive retransmissions occur.
Perform an End-to-End test. Refer to Pattern located in the Test Branch section of Chapter 3.
The modem establishes and then disconnects the call.
You may have a poor VF connection. Try dialing again.
The remote modem may have encountered an error control (EC) disconnect. If the modems cannot negotiate EC, then a disconnect occurs.
The remote modem may be in a forced Error Control mode (disconnect if there is no error control). Reconfigure your modem to V.42/MNP or Buffer and try again.
Check the LCD to determine the reason for the disconnect.
Perform a Local Analog Loopback test.
High error rates occur when running a local loopback or self-test.
Incoming rings can cause data errors during a loopback test. Abort the test, disconnect the modular VF cord, and restart the test.
Symptom Action
The data is scrambled. Verify that the character format (data bits, parity, and stop bits) is set to the same value in both modems.
Data is missing during a transfer. Verify that you are using the same method of flow control for both the modem and the DTE.
If using XON/XOFF flow control, verify that the modem’s parity matches the DTE’s parity.
Symptom Action
The MUX configuration option does not appear under DTE Interface.
The Dial Access Security feature is enabled. Verify that both the Answer and Originate security options are disabled. Refer to sections Set Answer Sec and Set Orig Sec in Chapter 6.
The Dial Line Rate or LeasedLine Rate configuration option is set to an invalid modulation. Refer to the Dial Line or Leased Line configuration option in the Multiport Mode section of Chapter 4 for the valid rates.
B-5 3920-A2-GN31-30 November 1996
Troubleshooting

Overview C-1 EIA-232-D Pin Assignments C-2 VF Connector Pin Assignments C-3 Auxiliary Cables Not Supplied C-4
This appendix lists EIA-232-D and VF TELCO pin assignments and provides information about auxiliary cables which are not supplied.
C-1 3920-A2-GN31-30 November 1996

Table C-1 lists the EIA-232-D pin assignments for the modem.

9 +12V — — — Reserved for test purposes (may be used to drive one RS-232 load)
10 –12V — — — Reserved for test purposes (may be used to drive one RS-232 load)
12 CT112 CI 112 DCE Data Signal Rate Select
13 — Reserved for future function
14 — Reserved for future function
16 — Reserved for future function
C-2 November 1996 3920-A2-GN31-30

Table C-2 lists the connector pin assignments for Model 3920Plus modular jacks as well as the pin assignments for the TELCO jacks. (See Figure C-1.)


C-3 3920-A2-GN31-30 November 1996
Pin Assignments

To add an external telephone to your modem, use an external “Y” cable to connect the phone line to both the modem and the telephone (Figure C-2).

C-4 November 1996 3920-A2-GN31-30

For 2-wire leased-line connections to a JM8 network interface, use an 8-position to 6-position crossover cable (Figure C-3) according to the following FCC requirements:
“The RJ series of jacks should not be used for connecting data equipment to nonswitched private line networks — specifically, the service equivalents of the pre-divestiture Series 3002 (Category II, Tariff #260) service. There is a substantial difference in transmit levels permitted in the private line service and those permitted in the public switched network. The industry standard is now an 8-pin keyed modular jack known as the USOC JM8 (Bellcore Technical Reference: TR-EOP-000242, Issue 1, released May 1985.) When ordering the installation of the USOC JM8, specify the appropriate wiring options:
TEK leads are for loopback purposes.
A 50-pin version is being considered for multiple line connections.”
8-POSITION PLUG PIN NO.
6-POSITION PLUG PIN NO.
C-5 3920-A2-GN31-30 November 1996
Pin Assignments

To connect a Model 3920Plus port to another modem’s EIA-232-D interface, use a 25-pin crossover cable (Figure C-4).
25-POSITION PLUG PIN NO.
25-POSITION PLUG PIN NO.
TXD
RXD
RXD
RTS
RTS
DSR
DSR
SG
SG
LSD
LSD
RXC
RXC
DTR
DTR
CT140
CT140
XTXC
XTXC
CT142 (TEST)
CT142 (TEST)
Figure C-4. Wiring Diagram — 25-Pin Crossover Cable
C-6 November 1996 3920-A2-GN31-30

CCITT V.25bis Dialing Command and Responses
Overview D-1 Call Request Commands D-2 Call Request with Number Provided (CRN) D-2 Call Request with Stored Memory Address Provided (CRS) D-2 Call Response D-2 Call Failure Indication (CFI) D-2 Call Connecting (CNX) D-3 Delayed Call Indicator D-3 Call Answer Commands D-3 Incoming Call (INC) D-3 Disregard Incoming Call (DIC) D-3 Connect Incoming Call (CIC) D-4 Program Normal (PRN) D-4 Request List of Delayed Numbers (RLD) D-4 Request List of Forbidden Numbers (RLF) D-4 Request List of Stored Numbers (RLN) D-5 List Delayed Numbers Response (LSD) D-5 List Forbidden Numbers Response (LSF) D-5 List Stored Number Response (LSN) D-5 Command Response D-6 Valid (VAL) D-6 Invalid (INV) D-6
This appendix describes V.25bis dialing commands and responses. CCITT V.25bis is an international dialing protocol that permits direct and stored number dialing using DTEs in either Asynchronous, bisynchronous, or HDLC operating mode. The 392xPlus modems support V.25bis request and answer commands. As commands are entered from the DTE, the 392xPlus modems issue a response to the DTE which indicates if the call failed or connected, or if the command is valid or invalid.
The following sections discuss those V.25bis commands supported by the 392xPlus modems and the response to those commands. Tables D-1 and D-2 list the V.25bis commands and response messages.
The 392xPlus modem must be configured for V.25bis dialing. Refer to DTE Dialer Type configuration option in Chapter 4, DCP Configuration.
D-1 3920-A2-GN31-30 November 1996

Call Request commands are issued from the DTE to the modem and are responsible for initiating dial calls. Call Request commands include Call Request with Number Provided (CRN) and Call Request with Stored Memory Address Provided (CRS).
The CRN command dials the telephone number entered from the DTE. CRN is similar to the ATD command.
The CRN command format is:
Where: n is the telephone number to be dialed.
The CRS command dials the telephone number stored in the request directory location. CRS is similar to the ATDS command.
The CRS command format is:
Where: x is directory location 1–24.
The modem responds to the command with either a VAL (valid) or INV (invalid) response followed by a call progress report such as connect (CNX) or failure (CFI).
A Call Response indicates if the command was accepted by the modem. Call Response includes Call Failure Indication (CFI) and Call Connecting (CNX).
The CFI response is issued to the DTE if the modem fails a CRN or CRS command. CFI is similar to the AT result codes BUSY, NO ANSWER, NO CARRIER, NO DIALTONE, and ERROR.
The CFI response format is:
ET Engaged tone. NS Number not stored. CB Local DCE busy. RT Time-out on ring tone. AB Abort call on time-out. NT Answer tone not detected. FC Forbidden call.
D-2 November 1996 3920-A2-GN31-30
CRNn · CRSx · CFIxx

CCITT V.25bis Dialing
ET is similar to the Call Failure Messages Busy Signal and Trunk Busy and the result code BUSY.
NS is similar to the Common Operational Message Invalid Number and the result code ERROR.
CB is similar to the Call Failure Messages Dial Line in Use and No Dial-Test and the result code ERROR.
RT is similar to the Call Failure Message No Answer Tone and the result code NO CARRIER.
AB is similar to the Call Failure Messages No Dial Tone and No Dial-DTR and the result code NO DIALTONE and ERROR.
NT is similar to the Call Failure Message No Quiet Answer and the result code NO ANSWER.
The CNX response informs the DTE that the modem has connected to the remote modem. CNX is similar to the AT result code CONNECT.
The CNX response format is CNX.
The DLC response is issued to the DTE if the modem is not currently allowed to call the number. DLC is similar to the AT result code DELAYED.
The DLC response format is:
Where: n is the delay (in minutes) before the number can be called.
Call Answer commands disable or enable the modem’s AutoAnswer function. These commands are issued from the DTE. Call Answer commands include Incoming Call (INC), Disregard Incoming Call (DIC) and Connect Incoming Call (CIC).
The INC response informs the DTE that the modem has detected a ring tone. At this point, the DTE can issue the DIC command to disable the modem from answering the call. INC is similar to the AT result code RING.
The DIC command prevents the modem from answering an incoming call. This command is only valid once the DTE receives an incoming call (INC) response from the modem. A DIC must be issued within 5 seconds after receiving an INC.
The DIC command format is DIC.
If DIC is issued within 5 seconds, the modem sends the VAL response to the DTE. If DIC is issued after 5 seconds, INV is returned.
D-3 3920-A2-GN31-30 November 1996
DLCn

The CIC command forces the modem to cancel any DIC commands and answer an incoming call. This command is only valid when the DTE issues a DIC command. CIC must be issued within 10 seconds after sending a DIC. CIC is similar to the ATA command.
The CIC command format is CIC.
If CIC is issued within 10 seconds, the modem sends the VAL response to the DTE. If CIC is issued after 10 seconds, INV is returned.
The Program Normal (PRN) command allows the DTE to enter and store a telephone number to a specific directory location. PRN is similar to the AT&Z command.
The PRN command format is:
PRNx;n
n is the telephone number.
The Request List of Delayed Numbers (RLD) command displays telephone numbers that are currently delayed as a result of failed call attempts. All the numbers currently delayed are displayed, irrespective of whether they belong to a directory location.
The RLD command format is RLD.
The Request List of Forbidden Numbers (RLF) command displays telephone numbers that are forbidden as a result of failed call attempts. All the numbers forbidden are displayed, irrespective of whether they belong to a directory location.
The RLF command format is RLF.
D-4 November 1996 3920-A2-GN31-30

CCITT V.25bis Dialing
The Request List of Stored Numbers (RLN) command displays telephone numbers stored in the modem’s directory location. If the RLN command is entered without specifying a directory location, then all directory locations and telephone numbers appear. If a directory location is entered, then only that telephone number appears.
The RLN command format is:
which displays all directory locations,
Where: x is a directory location.
LSD is a response to an LSD command issued by DTE.
LSDx;n;d
Where: x is a sequence number (not a directory location).
n is the telephone number.
d is the delay in minutes
The LSF response format is :
LSFx;n
Where: x is a sequence number (not a directory location).
n is the telephone number.
LSN is a response to an RLN command issued by the DTE. If a directory location is specified, then the telephone number for that location appears. If no directory location is specified, then all telephone numbers stored in memory appear.
The LSN response format is:
LSNx;n
n is the telephone number.
D-5 3920-A2-GN31-30 November 1996
or · RLNx

A Command Response indicates that the command entered was a valid or invalid entry. Command Response includes Valid (VAL) and Invalid (INV).
The VAL response indicates that the modem has accepted the V.25bis command issued by the DTE. VAL is similar to the AT result code OK.
The INV response indicates that the modem has received an incorrect V.25bis command from the DTE. INV is similar to the AT result code ERROR.
The INV response format is:
CU command unknown. MS message syntax error. PS parameter syntax error. PV parameter value error.
Table D-1 lists V.25bis commands supported by the 392xPlus modems.
(1 of 2) V.25bis Commands
V.25bis Command Description AT Command/ S-Register Equivalent
CRN Call Request with Number Provided ATD
CRS Call Request with Memory Address ATDS
INC Incoming Call Indication RING
DIC Disregard Incoming Call NONE
CIC Connect Incoming Call ATA
PRN Program Normal AT&Z
D-6 November 1996 3920-A2-GN31-30

CCITT V.25bis Dialing
(2 of 2) V.25bis Commands

Table D-2 lists V.25bis response messages supported by the 392xPlus modems.

CFI Call Failure Indication BUSY, NO ANSWER, NO CARRIER, NO DIAL TONE, ERROR
D-7 3920-A2-GN31-30 November 1996

ASCII Character Table
Overview E-1
Table E-1 in this appendix provides the ASCII character table.
(1 of 4) ASCII Characters

E-1 3920-A2-GN31-30 November 1996

(2 of 4) ASCII Characters

E-2 November 1996 3920-A2-GN31-30

(3 of 4) ASCII Characters

E-3 3920-A2-GN31-30 November 1996
ASCII Character Table

(4 of 4) ASCII Characters

E-4 November 1996 3920-A2-GN31-30

Default Configuration Options
Overview F-1
Table F-1 lists the six sets of default (preset) configuration options, labeled Sync Leased, Async Leased, TMp (Trellis Multipoint), Async Dial, Sync Dial, and UNIX Dial. These six sets contain the most commonly used configuration options for modems installed into these hardware environments. For information on setting the default configuration options, refer to the Overview section in Chapter 4.
F-1 3920-A2-GN31-30 November 1996

(1 of 10) Factory Default Configuration Options

Á
Á
Á
Á
Á
Á
33600 Port1 or Disable (Ports 2, 3, 4)
33600 Port1 or Disable (Ports 2, 3, 4)
28800 Port1 or Disable (Ports 2, 3, 4)
28800 Port1 or Disable (Ports 2, 3, 4)
24000 Port1 or Disable (Ports 2, 3, 4)
24000 Port1 or Disable (Ports 2, 3, 4)
Á
19200 Port1 or Disable (Ports 2, 3, 4)
19200 Port1 or Disable (Ports 2, 3, 4)
16800 Port1 or Disable (Ports 2, 3, 4)
16800 Port1 or Disable (Ports 2, 3, 4)
† Not applicable when Async/Sync mode is set to Async. Refer to Chapter 4, DCP Configuration, for additional information. Not applicable when MUX Mode is disabled.
F-2 November 1996 3920-A2-GN31-30

(2 of 10) Factory Default Configuration Options

14400 Port1 or Disable (Ports 2, 3, 4)
14400 Port1 or Disable (Ports 2, 3, 4)
12000 Port1 or Disable (Ports 2, 3, 4)
12000 Port1 or Disable (Ports 2, 3, 4)
Á
9600 Port1 or Disable (Ports 2, 3, 4)
9600 Port1 or Disable (Ports 2, 3, 4)
7200 Port1 or Disable (Ports 2, 3, 4)
7200 Port1 or Disable (Ports 2, 3, 4)
4800 Port1 or Disable (Ports 2, 3, 4)
4800 Port1 or Disable (Ports 2, 3, 4)
2400 Port1 or Disable (Ports 2, 3, 4)
2400 Port1 or Disable (Ports 2, 3, 4)
Á
Á
Á
Á
†† Not applicable when Async/Sync mode is set to Sync. Refer to Chapter 4, DCP Configuration, for additional information. Not applicable when MUX Mode is disabled.
F-3 3920-A2-GN31-30 November 1996
Default Configuration Options

(3 of 10) Factory Default Configuration Options

Á
Á
Á
Á
Á
Á
Á
Á
†† Not applicable when Async/Sync mode is set to Sync. Refer to Chapter 4, DCP Configuration, for additional information. Not applicable when MUX Mode is disabled.
F-4 November 1996 3920-A2-GN31-30

(7 of 10) Factory Default Configuration Options

Á
Á
Á
Á
Á
Á
Refer to Chapter 4, DCP Configuration, for additional information. Not applicable when MUX Mode is enabled.
F-8 November 1996 3920-A2-GN31-30

(8 of 10) Factory Default Configuration Options

Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
Á
†† Not applicable when Async/Sync mode is set to Sync. Refer to Chapter 4, DCP Configuration, for additional information. Not applicable when MUX Mode is enabled.
F-9 3920-A2-GN31-30 November 1996
Default Configuration Options

(9 of 10) Factory Default Configuration Options

Á
Á
Á
Á
Á
Á
Á
Á
(Trib – tmp trib) or (Control – tmp control)
Á
Á
Refer to Chapter 4, DCP Configuration, for additional information. Not applicable when MUX Mode is enabled. Not changed by loading factory default configuration options.
F-10 November 1996 3920-A2-GN31-30


Á
Á
Á
Á
Á
Á
Á
Not applicable when MUX Mode is enabled. Not changed by loading factory default configuration options.
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ
F-11 3920-A2-GN31-30 November 1996
Default Configuration Options

Sample Configurations
Overview G-1 Point-to-Point G-2 Configuration Options G-2 Cables G-3 Extended Point-to-Point G-4 Configuration Options G-4 Cables G-5 Extended Multipoint G-6 Configuration Options G-7 Cables G-8 Point-to-Point with Automatic Dial Backup G-8 Configuration Options G-9 Cables G-9 Point-to-Point with Network Management G-10 Configuration Options G-10 Cables G-11 Carrier with Network Management G-12 Configuration Options G-13 Cables G-13 Extended Diagnostics G-14 Configuration Options G-14 Cables G-15 Adapter G-15 Digital Bridging G-16 Cables G-17 Point-to-Point MSD G-18 Cables G-18 Multipoint MSD G-20 Cables G-21
This appendix provides diagrams of sample configurations for the 392xPlus modems. Following each diagram, the appropriate configuration options, cables, and sample line rates are listed.
G-1 3920-A2-GN31-30 November 1996

Figure G-1 shows a sample configuration for point-to-point applications.
DTE (Sync) DTE (Sync) 3920Plus A 3920Plus B
1 2 3 4
1 2 3 4
Cable 2 Cable 2
Configuration Options
3920Plus A Use Sync Leased (Answer) default configuration options with the following exception:
Rate Refer to Sample Port Rate Table in this section.
3920Plus B Use Sync Leased (Originate) default configuration options with the following exception:
Rate Refer to Sample Port Rate Table in this section.
G-2 November 1996 3920-A2-GN31-30

Sample Port Rate Table

Port Rate Port 1 Port 2 Port 3 Port 4
Á
Á
Á
Á
ÁÁÁ
ÁÁÁÁ
ÁÁÁÁ
ÁÁÁ
ÁÁÁÁ
Cables
Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1, 2, 3, or 4.
Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.
G-3 3920-A2-GN31-30 November 1996
Sample Configurations

Figure G-2 shows a sample configuration for extended point-to-point applications.
DTE (Sync) DTE (Sync) 3920Plus A 3920Plus B
1 2 3 4
1 2 3 4
Cable 2 Cable 2
4800(V32b) 4800(V32b) TX TX
Cable 1 Cable 2 Cable 2
Configuration Options
3920Plus A Use Sync Leased (Answer) default configuration options with the following exception:
Rate Refer to Sample Port Rate Table in this section.
3920Plus B Use Sync Leased (Originate) default configuration options with the following exceptions:
TX Clock Source Set to RXC_Loop. Rate Refer to Sample Port Rate Table in this section. Port TXC Source Set Port 4 to External.
G-4 November 1996 3920-A2-GN31-30

3910 A Use Sync Leased (Answer) default configuration options with the following exceptions:
TX Clock Source Set to External. LeasedLine Rate Set to 4800(V32b). Autorate (Leased Line) Set to Disable.
3910 B Use Sync Leased (Originate) default configuration options with the following exceptions:
TX Clock Source Set to RXC_Loop. LeasedLine Rate Set to 4800(V32b). Autorate (Leased Line) Set to Disable.
Sample Port Rate Table

Port Rate Port 1 Port 2 Port 3 Port 4
Á
Á
Á
Cables
Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1, 2, 3, or 4.
Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.
Cable 3 Use part number 818-2759-0111 or an equivalent customer-supplied, EIA-232-D/V.24 crossover cable with DB-25-P (plug) connectors on both ends to attach to the modems. (See Appendix C for pin assignments.)
G-5 3920-A2-GN31-30 November 1996
Sample Configurations

Figure G-3 shows a sample configuration for extended multipoint applications.

* This FEP Port is Running the Multipoint Application
Cable 1 Cable 2
G-6 November 1996 3920-A2-GN31-30

3920Plus A Use Sync Leased (Answer) default configuration options with the following exception:
Rate Refer to Sample Port Rate Table in this section.
3920Plus B Use Sync Leased (Originate) default configuration options with the following exceptions:
TX Clock Source Set to RXC_Loop. Rate Refer to Sample Port Rate Table in this section. Port TXC Source Set Port 4 to External.
3910 A Use TMp (Control) default configuration options with the following exceptions:
TX Clock Source Set to External. LeasedLine Rate Set to 4800(TMp). Autorate (Leased Line) Set to Disable.
3910 B Use TMp (Trib) default configuration options with the following exceptions:
TX Clock Source Set to RXC_Loop. LeasedLine Rate Set to 4800(TMp).
3910 C Use TMp (Trib) default configuration options with the following exceptions:
TX Clock Source Set to RXC_Loop. LeasedLine Rate Set to 4800(TMp). Autorate (Leased Line) Set to Disable.
Sample Port Rate Table

Port Rate Port 1 Port 2 Port 3 Port 4
Á
Á
G-7 3920-A2-GN31-30 November 1996
Sample Configurations

Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1, 2, 3, or 4.
Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.
Cable 3 Use part number 818-2759-0111 or an equivalent customer-supplied, EIA-232-D/V.24 crossover cable with DB-25-P (plug) connectors on both ends to attach to the modems. (See Appendix C for pin assignments.)
Figure G-4 shows a sample configuration for point-to-point applications with automatic dial backup.
Cable 4 Cable 4
3920Plus A 3920Plus B
Cable 1 Cable 1 Cable 2 Cable 2
G-8 November 1996 3920-A2-GN31-30

3920Plus A Use Sync Leased (Answer) default configuration options with the following exception:
Auto Dial Back Set to Enable. Rate Refer to Sample Port Rate Table in this section.
3920Plus B Use Sync Leased (Originate) default configuration options with the following exception:
Auto Dial Back Set to Enable. Rate Refer to Sample Port Rate Table in this section.
Sample Port Rate Table

Port Rate Port 1 Port 2 Port 3 Port 4
Á
Á
Á
Á
ÁÁÁ
ÁÁÁÁ
ÁÁÁÁ
ÁÁÁ
ÁÁÁÁ
Cables
Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1.
Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.
Cable 4 Use part number 125-0067-0031 (a 6-position, 4-wire modular cord that is supplied with the modem). Attach this to the connector labeled DIAL.
G-9 3920-A2-GN31-30 November 1996
Sample Configurations

Figure G-5 shows a sample configuration for point-to-point applications with network management.
DTE (Sync) DTE (Sync) 3920Plus A 3920Plus B
1 2 3 4
1 2 3 4
Cable 2 Cable 2
NMS (6700
or 6800) Adapter (002-0025-0031)
Configuration Options
3920Plus A Use Sync Leased (Answer) default configuration options with the following exception:
Rate Refer to the Sample Port Rate Table in this section. Diag Connection Set to NMS(CC). NetworkPosition Set to Control. NetMngmtAddress Set to 1.
3920Plus B Use Sync Leased (Originate) default configuration options with the following exception:
Rate Refer to the Sample Port Rate Table in this section.
G-10 November 1996 3920-A2-GN31-30

Sample Port Rate Table

Port Rate Port 1 Port 2 Port 3 Port 4
Á
Á
Á
Á
ÁÁÁ
ÁÁÁÁ
ÁÁÁÁ
ÁÁÁ
ÁÁÁÁ
Cables
Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1, 2, 3, or 4.
Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.
Cable 5 Use part number 835-1224-1011 (10 feet), part number 125-0040-0031 (12 feet), part number 835-1224-2511 (25 feet), part number 835-1224-5011 (50 feet), or an equivalent pin-to-pin, 6-position, 6-wire modular cord. The maximum cable length is 50 feet.
G-11 3920-A2-GN31-30 November 1996
Sample Configurations

Figure G-6 shows a sample configuration for COMSPHERE 3000 Series Carrier applications with network management.
DTE (Sync) DTE (Sync) 3921Plus 3920Plus
1 2 3 4
1 2 3 4
Cable 2 Cable 2
COMSPHERE 3000 Series Carrier
or 6800) Adapter (002-0025-0031)
G-12 November 1996 3920-A2-GN31-30

3921Plus Use Sync Leased (Answer) default configuration options with the following exception:
Rate Refer to the Sample Port Rate Table in this section. Diag Connection Set to NMS(CC). NetMngmtAddress Set to 1.
3920Plus Use Sync Leased (Originate) default configuration options with the following exception:
Rate Refer to the Sample Port Rate table in this section.
Sample Port Rate Table

Port Rate Port 1 Port 2 Port 3 Port 4
Á
Á
Á
Á
ÁÁÁ
ÁÁÁÁ
ÁÁÁÁ
ÁÁÁ
ÁÁÁÁ
Cables
Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1, 2, 3, or 4.
Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.
Cable 5 Use part number 835-1224-1011 (10 feet), part number 125-0040-0031 (12 feet), part number 835-1224-2511 (25 feet), part number 835-1224-5011 (50 feet), or an equivalent pin-to-pin, 6-position, 6-wire modular cord. The maximum cable length is 50 feet.
G-13 3920-A2-GN31-30 November 1996
Sample Configurations

Figure G-7 shows a sample configuration for extended diagnostics.

Configuration Options
3920Plus A Use Sync Leased (Answer) default configuration options with the following exception:
NetworkPosition Set to Control. Diag Connection Set to NMS(CC). NetMngmtAddress Set to 1.
3920Plus B Use Sync Leased (Originate) default configuration options with the following exception:
Tx Clock Source Set to RXC. Diag Connection Set to Modem(DC). Port Tx Source Set Port 1 to External.
G-14 November 1996 3920-A2-GN31-30

3920Plus C Use Sync Leased (Answer) default configuration options with the following exceptions:
Tx Clock Source Set to External. Extended Channel Set Port 1 to Enable. Upstream Port # Set to Port 1. Diag Connection Set to Modem(DC). NetworkPosition Set to Control.
Use Sync Leased (Originate) default configuration options with the following exceptions:
Tx Clock Source Set to RXC_Loop.
3920Plus E 3910 G Use Sync Leased (Answer) default configuration options with the following exceptions:
Diagnostic Connection Set to Modem(DC). NetworkPosition Set to Control.
Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1, 2, 3, or 4.
Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.
Cable 3 Use part number 818-2759-0111 or an equivalent customer-supplied, EIA-232-D/V.24 crossover cable with DB-25-P (plug) connectors on both ends to attach to the modems. (See Appendix C for pin assignments.)
Cable 6 Use part number 125-0040-0031 (a 6-position, 6-wire modular cord). Attach this to the CCIN/DCOUT port of the 3600 Hubbing device.
Cable 7 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord). Attach this to the CCIN/DCOUT port of one 3600 Hubbing device and to the CCOUT/DCIN port of the second device.
871A Use part number 002-0026-0031 (Feature number 4400-F1-590).
G-15 3920-A2-GN31-30 November 1996
Sample Configurations

Figure G-8 shows a sample for Digital Bridging.

3920Plus A Use TMp Control Template default configuration options with the following exception:
MUX Mode Set to DTE Bridge.
Use Sync Dial template default configuration options with the following exceptions:
MUX Mode Set to DTE Bridge. NetworkPosition Set to Control. Diag Connection Set to NMS(CC). Tx Clock Source Set to Port 1. LSD Control Set to Sim_Cntl_Car. DTR Action Set to Ignore.
3910Plus D Use Sync Dial template default configuration options with the following exceptions:
NetworkPosition Set to Control. Diag Connection Set to NMS(CC). Tx Clock Source Set to External. LSD Control Set to Sim_Cntl_Car.
G-16 November 1996 3920-A2-GN31-30

Use TMp Tributary template default configuration options with the following exceptions:
Port2 MSD Set to Enable. RTS Action Set to Sim_Cntl_Car. Auto Dial Back Set to Enable. Auto Dial Standby Set to Adv 15min. Dial Line Rate Set to 14400(V32).
3920Plus F Use TMp Tributary template default configuration options with the following exceptions:.
RTS Action Set to Sim_Cntl_Car. Auto Dial Back Set to Enable. Auto Dial Standby Set to Adv 15min. Dial Line Rate Set to 14400(V32).
Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1, 2, 3, or 4.
Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.
Cable 3 Use part number 818-2759-0111 or an equivalent customer-supplied, EIA-232-D/V.24 crossover cable with DB-25-P (plug) connectors on both ends to attach to the modems. (See Appendix C for pin assignments.)
Cable 4 Use part number 125-0067-0031 (a 6-position, 4-wire modular cord that is supplied with the modem). Attach this to the connector labeled DIAL.
G-17 3920-A2-GN31-30 November 1996
Sample Configurations

Figure G-9 shows a sample configuration for point-to-point MSD.

3920Plus A Use Sync Lease Answer Template default configuration options with the following exception:
Rate Refer to the Sample Port Rate Table in this section.
3920Plus B Use Sync Lease Originate Template default configuration options with the following exception:
MSD Control Set Ports 1, 2, and 3 to Enable. Rate Refer to the Sample Port Rate Table in this section.
Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1, 2, 3, or 4.
Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.
Cable 3 Use part number 818-2759-0111 or an equivalent customer-supplied, EIA-232-D/V.24 crossover cable with DB-25-P (plug) connectors on both ends to attach to the modems. (See Appendix C for pin assignments.)
G-18 November 1996 3920-A2-GN31-30


Port Rate Port 1 Port 2 Port 3 Port 4
Á
Á
Á
Á
ÁÁÁ
ÁÁÁÁ
ÁÁÁÁ
ÁÁÁ
ÁÁÁÁ

Port Rate Port 1 Port 2 Port 3 Port 4
Á
Á
Á
ÁÁÁ
ÁÁÁÁ
ÁÁÁÁ
ÁÁÁ
ÁÁÁÁ
G-19 3920-A2-GN31-30 November 1996
Sample Configurations

Figure G-10 shows a sample configuration for multipoint MSD.

3920Plus A Use TMp Control Template default configuration options with the following exception:
NetworkPosition Set to Control.
Use TMp Control Template default configuration options with the following exception:
MSD Control Set Ports 1, 2, 3, and 4 to Enable.
G-20 November 1996 3920-A2-GN31-30

Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1, 2, 3, or 4.
Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.
G-21 3920-A2-GN31-30 November 1996
Sample Configurations

Equipment List
Model 3920Plus 3920-A1-XXX
Model 3921Plus 3921-B1-XXX
6-position, 4-wire modular cord, 7-foot length 125-0067-0031
8-position, 8-wire modular cord, 14-foot length 125-0053-1431
Universal Power Supply 327-0074-XXXX
3600 Hubbing Device 3600-F3-300
EIA-323-D/V.24 Crossover Cable 818-2759-0111
6-position, 6-wire modular cord 125-0040-0031
8-position, 8-wire modular cord 125-0053-1431
H-1 3920-A2-GN31-30 November 1996
871A Adapter 002-0026-0031

Active (Operating) A configuration area containing configuration options currently in use by the modem. Any time a power cycle occurs or a reset is performed or a save is issued using the DCP, this area is updated with the contents of Active (Saved).
Active (Saved) A nonvolatile configuration area containing the most recently saved configuration options.
ADp Advanced Diagnostic protocol. An enhanced diagnostic communication protocol used with the 6800 Series NMS and with certain DCP diagnostic functions.
analog loop See local analog loop.
analog signal A signal, such as a voice, that varies continuously.
Answer mode The modem is in a state where it is ready to receive an incoming call.
ASCII This code (American Standard Code for Information Interchange) is a 7-bit code which establishes compatibility between data services. ASCII is the standard for data transmission over telephone lines. The ASCII code consists of 32 control characters (nondisplayed) and 96 displayed characters. Refer to Appendix E.
A data transmission that is synchronized by a transmission start bit at the beginning of a character (five to eight bits) and one or more stop bits at the end.
AT command set A group of commands, issued from an asynchronous DTE, that allow control of the modem while in Command mode. All commands must begin with the characters AT and end with a carriage return.
AT prefix A prefix issued before every AT command (except A/ and +++) which identifies the DTE’s data rate, parity, and character length.
autobaud The modem automatically determines the asynchronous DTE data rate when using AT commands.
automatic answer A capability to respond to a call received over a dial line.
automatic dial backup When leased-line operation fails, this function forces the modem to dial the telephone number stored in directory location 1.
Glossary-1 3920-A2-GN31-30 November 1996

automatic dial standby When operating in Dial Backup mode, this function forces the modem to periodically check the quality of the leased line. If the leased line is found to be at normal operating condition, the modem disconnects from the dial network and continues normal operation over the leased-line network.
automatic rate control Modems adjust their signaling rate based on current line conditions.
backbone network The primary route from a control modem to its first tributary when the communications network contains extended control modems.
backplane A common bus at the rear of the COMSPHERE 3000 Series Carrier connecting each circuit card slot to the SDCP and/or SDU. It also distributes low-voltage ac power to each slot.
baud A unit of signaling speed that is equal to the number of symbols per second. This is not necessarily the same as bits per second, although the terms are frequently interchanged.
Bisync Binary Synchronous Communications. An IBM communications protocol that has become an industry standard. It uses a defined set of control characters and control-character sequences for synchronized transmission of binary-coded data between stations in a data communications system.
bit A contraction of binary digit. A bit, which is the smallest unit of information, represents the choice between a one or a zero (sometimes called mark or space).
bps Bits per second. Indicates the speed at which bits are transmitted across a data connection.
broadcast A method of transmission. The simultaneous transmission to two or more communicating devices.
buffer A storage device used to compensate for differences in the data flow rate when transmitting data from one device to another.
byte A sequence of successive bits (usually eight) handled as a unit in data transmission.
carrier The rack mounting that contains 17 slots: 1 control slot for an SDU and 16 modem slots. See data carrier.
carrier-mount A modem that is designed for installation in a COMSPHERE 3000 Series Carrier and used at central-site operations.
CCITT An advisory committee (Consultative Committee on International Telephone and Telegraph) established by the United Nations to recommend communications standards and policies.
channel A path for electrical transmission between two or more points. Also called a circuit, line, link, path, or facility.
character A letter, figure, number, punctuation, or other symbol.
character echo A way to check the accuracy of data transmission by sending to the monitor (displaying) all the characters being transmitted.
Glossary-2 November 1996 3920-A2-GN31-30

circuit pack lock A screw lock tab installed over a circuit card’s latch release tab to prevent the unit from being removed without a tool. It is used on SDUs, modems, and filler panels.
command mode One of two modem operating modes. When in Command mode, the modem accepts commands instead of transmitting or receiving data.
compandor A combination of a compressor at one point in a communication path for reducing the volume range of signals, followed by an expandor at another point for restoring the original volume range. Usually its purpose is to improve the ratio of the signal to the interference in the path between the compressor and expandor.
configuration area One of five areas within the Configure branch containing modem settings. Configuration areas include Active (Operating), Active (Saved), Customer 1, Customer 2, and Factory.
configuration option Modem software that sets specific operating parameters for the modem. Sometimes referred to as straps.
connector An outlet on equipment and cables that provides a connection.
constant carrier mode The modem transmits a carrier signal constantly, regardless of RTS.
Control Channel (CC) The diagnostic interface between a network management system and a network device.
control modem A control modem polls downstream tributary modems across the analog channel.
controlled carrier mode The modem’s transmitter turns on and off in response to RTS. This mode is used by multipoint tributary modems.
Customer 1 A user-defined configuration area containing customized configuration options for a specific application.
Customer 2 A user-defined configuration area containing customized configuration options for a specific application.
DAA Data Access Arrangement. Hardware that acts as a protective interface between the telephone circuit and the modem. It performs such functions as ring detection, DC isolation, and surge protection to protect the circuit from being disturbed by a modem malfunction. The 392xPlus modems contain three dip switches that allow the DAA hardware to be configured for use in different countries.
data bank An area within the modem used to store the modem’s firmware. There are two data banks in the 392xPlus modem.
data carrier A continuous frequency signal that can be modulated by another signal that contains information to be transmitted.
data compression The elimination of empty fields, redundancies, and gaps in order to reduce storage capacity needs and the amount of data to be transmitted. Anything that is eliminated is restored after the data is received.
data mode One of two modem operating modes. When in Data mode, the modem transmits and receives data instead of accepting commands.
DB-25 connector A 25-pin connector that is used to connect a cable which enables communication between two devices.
Glossary-3 3920-A2-GN31-30 November 1996
Glossary

dBm A decibel referenced to one milliwatt. This unit measures relative signal power.
DCE The equipment (Data Communications Equipment or Data Circuit Terminating Equipment) that provides the functions required to establish, maintain, and end a connection. This equipment also provides the signal conversion required for communication between the DTE and the telephone line.
DCP Diagnostic Control Panel. The face of the modem that continuously provides status information about the modem’s operation and allows an operator to manage its operation. This is a generic term used for both the standalone and carrier-mounted models. See SDCP.
demodulation The process of recovering data from a modulated carrier wave.
DevHS Device Health and Status. A detailed account of device alarms.
Diagnostic Channel (DC) The diagnostic interface between two network devices, used to extend the NMS diagnostics to downstream devices.
dial command modifiers A modifier used in the dial string that instructs the modem how to process a dialed telephone number.
dial line A communications circuit that is established by a switched circuit connection in the dial network.
dial network See PSTN.
Dial Standby A function available when the modem is operating in Dial Backup mode, allowing the modem to switch back to lease-line operation while still maintaining the dial-line connection.
dial string A series of characters that consists of numbers and modifiers used to dial a telephone number.
digital bridging Provides the capability of dial backup in a multipoint configuration by bridging the signal on the digital side of the front end panel.
directory location Nonvolatile memory that stores up to ten telephone numbers. Each directory location can have up to 40 characters entered.
DOC Canadian Department of Communication.
download A process that transfers modem firmware from a locally attached PC to a modem or allows the cloning of firmware from a local modem to a remote modem.
downstream modem A device connected “farther” from the host computer.
DTE The equipment (Data Terminal Equipment), such as a computer or terminal, that provides data in the form of digital signals.
edit area A temporary work area used to view and change configuration options from the DCP. The edit area can be loaded from one of five configuration option areas, Active (Operating), Active (Saved), Customer 1, Customer 2, or Factory.
Glossary-4 November 1996 3920-A2-GN31-30

EIA Electronic Industries Association. This organization provides standards for the data communications industry.
EIA-232-D An Electronic Industries Association’s standard defining the 25-position interface between data terminal equipment and data communications equipment.
EIA RS-366-A An Electronic Industries Association’s standard defining the 25-position interface between data terminal equipment and data communications automatic calling equipment.
error control An algorithm used to correct data transmission errors.
escape sequence Default setting is +++. This sequence lets you switch your modem from Data mode to Command mode.
extended circuit See extended network.
extended network The extension of a circuit where the tributary DCE is connected to a downstream (extended) control DCE.
extended result codes An asynchronous message (in either numbers or words) that includes VF data rate and error control information the modem sends to the DTE after executing or trying to execute a command.
fallback Retraining at a lower rate or speed.
FCC Federal Communications Commission. Board of Commissioners that regulates all interstate and foreign electrical communication systems that originate from the United States.
FEC Forward Error Correction. A method of error control for data transmission where the receiving device can detect and correct a character or block of code containing a predetermined number of erroneous bits.
FEP Front-End Processor. A communications computer associated with a host computer that manages the routing of data through the network.
full-duplex Simultaneous, two-way communications.
function key Any one of three keys on the DCP that allows you to select or increment an LCD entry. Function keys are labeled F1, F2, and F3.
half-duplex Two-way data communications allowed in only one direction at a time.
handshaking The exchange of predetermined codes and signals (tones) to establish a connection between two modems.
HDLC High-Level Data Link Control. A communications protocol defined by the International Standards Organization (ISO).
host A computer attached to a network that shares its information and devices with the rest of the network.
Hz A unit of frequency (Hertz) that equals one cycle per second.
Glossary-5 3920-A2-GN31-30 November 1996
Glossary

idle A state in which the modem’s operating parameters can be modified or commands can be issued to the modem using either AT commands or the DCP.
JM8 A jack used for leased-line networks. Pins 1 and 2 are the transmit pair and Pins 7 and 8 are the receive pair.
keypad A set of seven keys surrounding the DCP’s LCD. These keys are used to select configuration options and to maneuver through the DCP menu.
LCD Liquid Crystal Display. A thin sandwich of two sealed glass plates containing liquid crystal material. When voltage is applied, the amount of light able to pass through the glass plates is altered so that messages may be “written” on the display.
leased line A private telephone line connection exclusively for the user. No dialing is necessary.
LED Light Emitting Diode. A light or status indicator on the DCP that glows in response to the presence of a certain condition (e.g., an alarm).
local analog loopback The modem’s transmit VF signal is looped to its receiver.
long space disconnect A disconnect can occur if the modem receives an extended space from a remote modem; for example, when a remote modem is commanded to disconnect, it transmits a continuous space to the local modem before disconnecting.
loopback test Any test that verifies a device’s integrity by connecting the device’s output to the device’s input, then checking the received signal for errors.
menu tree The structure containing the menu hierarchy starting at a Top-Level menu and extending down to various modem functions.
mixed inbound rates In a multipoint network, several different data rates from tributary modems’ transmitters communicating with one control modem.
MNP This protocol (Microcom Networking Protocol) detects and corrects data errors caused by telephone line noise and signal distortion. MNP5 includes data compression.
modem (Modulator/DEModulator). A device that transforms signals from digital to analog form and vice versa.
modulation The process of varying some characteristics (usually amplitude, frequency, and/or phase) of a carrier wave to form data transmissions.
MSD Modem Sharing Device. Allows from 2 to 4 physical ports to share a communication channel.
multiplexer (mux) A device that enables the simultaneous transmission of multiple independent data streams into a single high-speed data stream.
multipoint line A circuit connecting one control modem with one or more tributary modems.
Multiport mode Multiport mode operates only in multiport modems. It is determined by your modem model and the selected MUX mode configuration option. Multiport mode is in effect when the MUX mode configuration option is set to TDM/MSD or DTE_Bridge. It supports from one to four ports depending on how the modem is further configured.
Glossary-6 November 1996 3920-A2-GN31-30

network A communications circuit.
The customer-assigned diagnostic address of a modem.
NIM Network Interface Module. The interface provided, up to two per carrier, for the public switched telephone network (PSTN).
non-linear distortion VF line distortion which is usually associated with pulse-code modulation (PCM) compandor noise on the phone line.
NMS Network Management System. A set of diagnostic and configuration management tools for a data communication network, consisting of software programs and dedicated computer hardware.
off-hook A telephone or modem is being used.
on-hook A telephone or modem is not being used.
Originate mode The modem is in a state where it is ready to transmit a call. In a dial network, it is the modem that makes the call. In a leased-line network, it is one of two sides of the network that is selected to be the originating modem.
parity A way of checking data accuracy by counting the number of bits that have a value of one.
PBX Telephone switching equipment (Private Branch Exchange) dedicated to one customer. A PBX connects private telephones to each other and to the public dial network.
permissive interface A dial modem operating mode characterized by a fixed output power level of –9 dBm.
phase jitter A rapid or repeated shifting of the relative phase of a signal resulting in unwanted distortion.
physical address The diagnostic address of a control modem derived from its location in the carrier: its carrier and slot number.
point-to-point line A line or circuit connecting two stations.
poll list A list containing the network management addresses of downstream modems.
power-up self-test A test that checks most hardware components when the modem is powered-on.
product code A three-digit code indicating the modem’s highest VF data rate.
protocol The rules for timing, format, error control, and flow control during data transmission.
PSTN Public Switched Telephone Network. A network shared among many users who can use telephones to establish connections between two points. Also known as dial network.
An informative display screen available from the modem’s Top-Level display. It provides such information as network position (control or tributary), network management address, DTE mode (Asynchronous or Synchronous), Line mode (Leased Answer, Leased Originate, or Dial), and the modulation scheme used by the modem.
Glossary-7 3920-A2-GN31-30 November 1996
Glossary

register A part of the modem’s memory that contains values that determine the modem’s operating characteristics.
Remote A branch of the Top-Level menu that permits access to the DCP of another modem.
remote loopback A test that sends a signal to the remote modem to test the local modem, the remote modem, and the circuit between them.
result code An asynchronous message (in either numbers or words) that the modem sends to the DTE after executing or trying to execute a command.
Return to Dial A function available when in Dial Backup mode that allows the modem to switch to dial-line operation when currently on leased lines.
RJ11 A type of 6-position jack normally used with permissive dial networks and telephone sets.
RJ21 A type of 50-position jack normally used with permissive dial networks providing the appropriate conductors for up to eight telephone lines.
SDCP Shared Diagnostic Control Panel. An optional user interface that attaches to the front of a COMSPHERE 3000 Series Carrier. Its functionality is very similar to that of the DCP. Installed in one COMSPHERE 3000 Series Carrier, it controls and monitors modems in all the carriers in the cabinet. A single SDCP can control up to 8 carriers, with a total of 128 modems.
SDU Shared Diagnostic Unit. A circuit card that plugs into a dedicated slot in the COMSPHERE 3000 Series Carrier to provide the SDCP and network management interfaces to the modems in the carrier. It translates the network management protocol to the devices in the carrier and routes incoming messages to the appropriate slots.
secondary channel A data transmission channel with a lower signaling rate than the primary channel. It is mostly used for modem diagnostics.
Select key An SDCP key that allows the selection of a specific card slot in the COMSPHERE 3000 Series Carrier.
serial transmission A way of transmitting data in which bits are sent sequentially one at a time.
Singleport mode A Model 392xPlus operational mode is available in both the singleport and multiport modem. Singleport mode only supports one port. For the multiport modem, it is in effect when the MUX mode configuration option is set to Disable. Singleport mode is the only operational mode for the singleport modem.
S-Registers Registers that contain information affecting the modem parameters. All S-Registers must be preceded by the AT prefix.
SubHS Sub-Network Health and Status. A display of alarm occurrences in downstream modems.
synchronous transmission Data transmission that is synchronized by timing signals. Characters are sent at a fixed rate. This type of transmission is more efficient than asynchronous transmission.
Glossary-8 November 1996 3920-A2-GN31-30

TDM Time Division Multiplexer. A device that enables the simultaneous transmission of multiple independent data streams into a single high-speed data stream by simultaneously sampling the independent data streams and combining these samples to form the high-speed stream.
TMp Trellis Multipoint. Paradyne’s proprietary high speed, fast poll multipoint modulation scheme.
Top-Level menu The very top of the menu tree that displays modem status and all Top-Level menu branches.
training A process where two modems try to establish a connection over the VF line.
trellis-coded modulation A modulation scheme developed by Paradyne which uses Forward Error Correction for multipoint and high-speed point-to-point applications.
tributary modem Tributary modems in a network receive data from the control modem, as well as from the network management system in the network.
UL Underwriter’s Laboratories, Inc.
UNIX Dial A factory preset configuration area containing the configuration options most often used in a UNIX dial network.
upstream modem A device connected “closer” to the host computer.
USOC Universal Service Ordering Codes.
V.22 A CCITT standard for modems operating full-duplex over dial networks at 1200 bps.
V.22bis A CCITT standard for modems operating full-duplex over leased lines or dial networks at 2400 bps.
V.27bis A CCITT standard for modems operating over leased lines at 2400 or 4800 bps.
V.29 A CCITT standard for modems operating over leased lines at 4800, 7200, or 9600 bps.
V.32 A CCITT standard for modems operating full-duplex with asynchronous or synchronous data over leased lines or dial networks at 4800 or 9600 bps.
V.32bis A CCITT standard for modems operating full-duplex with asynchronous or synchronous data over leased lines or dial networks at 4800, 7200, 9600, 12,000, or 14,400 bps.
V.32 terbo A modulation that adds the 19,200 bps and 16,800 bps data rates to the V.32bis data rates. It is a Paradyne proprietary modulation, not a CCITT standard.
V.34 A CCITT standard for modems operating full-duplex with asynchronous or synchronous data over leased lines or dial networks at 28,800, 26,400, 24,000, 21,600, 19,200, 16,800, 14,400, 12,000, 9600, 7200, 4800, 2400 bps.
V.42 A CCITT standard for error control protocol.
V.42bis A CCITT standard for data compression.
V.54 A CCITT standard for local and remote diagnostic loopback tests.
Glossary-9 3920-A2-GN31-30 November 1996
Glossary

VF Voice Frequency. The part of the audio frequency range used to transmit voice sound (usually 300 Hz to 3400 Hz). This band is used by the modem for its modulated signal.
XOFF A character that tells the DTE or modem to stop transmitting data.
XON A character that tells the DTE or modem to start or resume transmitting data.
Glossary-10 November 1996 3920-A2-GN31-30

F
data access arrangement, 1-2 data compression, 4-59 data rates. See rates DATAKIT, 4-16, 4-38, 4-41 DataStream, 3-37 default configuration options, 2-11–2-12, 4-2, F-2–F-7 diagnostic control panel (DCP)
faceplate, 1-5, 1-6, 3-3 factory default configurations, 2-11, 4-2, F-2–F-7 features, 1-7–1-8 firmware part number (FPt #), 3-23 firmware revision level (FRev), 3-23 firmware upgrades/download, 3-42–3-49 flow control, 4-60, 4-61 front panel. See diagnostic control panel function keys, 3-7, 3-9, 4-7
configurations. See configuration options description, 1-5–1-6, 3-2–3-3 menu tree, 3-9, 3-10, A-1–A-3 messages, 3-11–3-16, 3-18–3-19, 3-27–3-28 operation, 2-12, 3-7–3-9, 4-4–4-7, 6-7 status indicators (LEDs), 3-3–3-6 diagnostic tests. See Test branch dial
Canada, 1-12 United States, 1-11–1-12
access security. See Security answering a call
auto-answer, 3-74, 4-19, 4-46 manual answer, 3-68, 3-75, 4-19, 4-46 backup, 2-5–2-6, 3-41–3-42, 3-65, 3-68–3-69, B-2 command modifiers, 3-72, 5-6 DCP controlled, 3-65–3-73 manual dial. See Talk/Data network connection, B-4–B-5 stored telephone number, 3-70–3-73, 5-13 Dial Line configuration options group, 4-22, 4-50 digital bridge, 1-9, 1-10
handshaking sequence, 3-74, 3-75 hang up, 3-67 hardware part number (HPt #), 3-23 HDLC, 4-41, D-1 Health and Status definitions, 3-18–3-19, 3-27–3-28
sample configuration, G-16 digital loopback, 3-58–3-59, 3-60–3-61 dimensions, 1-14 directory, telephone number, 3-70–3-73 disconnecting a call, 3-67 Download Software, 3-42–3-49 DTE
Identity, 3-23 indicators, status (LEDs), 3-3–3-6 installation
connection, 2-4–2-6, B-3 status, 3-3–3-6, 3-24 DTE Bridge. See digital bridging DTE Dialer configuration options group, 4-41 DTE Interface configuration options group, 4-10, 4-33 dual leased-line operation. See backup, leased
Model 3920Plus, 2-3–2-12 Model 3921Plus, 2-6–2-10
E
cable connection, 2-4–2-6, B-3 pin assignments, C-2 status, 3-3–3-6, 3-24 end-to-end pattern test, 3-62 environment, 1-13 equipment
LCD (liquid crystal display)
description, 3-2, 3-7–3-8 menu structure, 3-10 messages, 3-11–3-16, 3-18–3-19, 3-27–3-28 leased backup operation. See backup, leased Leased Line configuration options group, 4-24, 4-53 leased-line connection, 2-5–2-6 leased-line operation, 4-24–4-26, 4-53–4-57, B-2 LEDs (status indicators), 3-3–3-6 line connection
customer supplied, 2-2 list, 2-1–2-2 error control, 4-58 escape character ( + + + ), 4-42, 5-2, 5-16
dial, 2-5–2-6 leased, 2-5–2-6 Line Dialer configuration options group, 4-19, 4-46
Index-2 November 1996 3920-A2-GN31-30
government requirements · keypad, 3-8–3-9

Load Number (LN), 1-12 loopback
network interface module (NIM), 2-2, 3-41 network management address, 3-31, 4-29, 4-68 network management system connection, 2-6
local analog, 3-57–3-58 local digital, 3-60–3-61 remote digital, 3-58–3-59
M
Make Busy, 3-40–3-41 manual dial. See Talk/Data menu
AT commands, 5-1 Talk/Data, 3-10, 3-73–3-75 operational messages, 3-11–3-16 Options, Status branch, 3-28 options, strap. See configuration options originate access security, 6-2, 6-15, 6-16
structure, 3-10 tree, A-1–A-3 messages
LCD, 3-11–3-16, 3-18–3-19, 3-27–3-28 result codes, 5-3–5-4 Misc configuration options group, 4-28, 4-66 mixed inbound rates, 4-53 Model 3920Plus
standalone multiport, 1-2 standalone singleport, 1-2 Model 3921Plus
part numbers, 3-23 passwords
administrative, 6-5–6-6 remote access, 3-76, 3-78, 3-79, 4-4–4-7, 4-28, 4-67 security, 6-2–6-4, 6-15–6-16 pattern test, 3-61–3-63 phone. See telephone, external phone numbers. See telephone numbers pin assignments, C-2 PList (Poll List) branch, 3-10, 3-30–3-35 power consumption, 1-14 power supply connection, 2-5–2-6 power-up self-test, 2-11 public switched telephone network (PSTN). See dial pulse-code modulation, 3-22
carrier-mounted mulitport, 1-4 carrier-mounted singleport, 1-4 Model 392xPlus, 1-2
features, 1-7 menu structure, 3-9 operational modes, 1-7 model number (Mod #), 3-23 modifiers, dial string, 3-72, 5-6 modulation (dial line configuration option), 4-22, 4-24,
4-50, 4-53 modulation schemes
dial line, 1-13, 4-22, 4-50, 5-18 leased line, 1-13, 4-24, 4-53, 5-19 MSD (Modem Sharing Device), 1-9 multiplexer (TDM). See MUX mode multipoint operation, 1-8–1-10 multiport, backup, 1-10 Multiport mode, 1-10, 4-8
quick configuration display, 1-10, 3-15
Dial Line, 4-22–4-23 DTE Interface, 4-10–4-18 Leased Line, 4-24–4-26 Line Dialer, 4-19–4-21 Misc, 4-28–4-32 Test, 4-27 multiport modem, 1-2, 1-7
automatic control, 4-24, 4-54 dial line, 1-14, 4-22, 4-50, 5-18 leased line, 1-14, 4-24, 4-53, 5-19 rear connector plate, 1-6 rear panel connectors, C-2 Record, Status branch, 3-28–3-30 Remote
model 3921Plus, 1-4 MUX mode, 1-7, 1-9, 4-10
DTE Bridge, 4-10 mux disabled, 1-7 mux enabled, 1-7 TDM/MSD, 1-9, 4-10
access password, 3-76, 3-78, 3-79, 4-4–4-7, 4-28, 4-67 branch, 3-10, 3-76–3-80 remote digital loopback test, 3-58–3-59 requirements
ac power, 1-13 government, 1-11–1-12
Index-3 3920-A2-GN31-30 November 1996

reset control, 3-37 result codes
enable/disable, 4-43, 5-7 extended, 4-43, 5-8 list, 5-3–5-4 numeric or word, 4-44, 5-7 ringer equivalence number (REN), 1-11
branch, 3-10, 3-73–3-75 telephone, external, 3-73, C-4 TDM/MSD, 1-2, 1-7, 1-10, 4-10 technical specifications, 1-13–1-14 telephone, external, 3-73, C-4 telephone numbers
display, 3-66 storage, 3-71 Test branch, 3-10, 3-54–3-63
S-Register list, 5-15–5-28 Security
Abort, 3-55 Local Analog Loopback, 3-57–3-58 Local Digital Loopback, 3-60–3-61 Pattern, 3-61–3-63 Remote Digital Loopback, 3-58–3-59 Self, 3-56 Test configuration options group, 4-27 test configuration options group, 4-64 time division multiplexer. See multiplexer TMp default configurations. See default configuration
access messages, 3-14 branch, 3-10, 6-4–6-13 configuration options, 6-13–6-14 database tables, 6-2, 6-3, 6-16–6-17 passwords, 6-2–6-4, 6-15–6-16 Security configuration options group, 4-68 Select key, 2-9, 3-8, 3-9 self-test, 3-56 self-test, 2-11 serial number (Ser #), 3-23 service line, 3-41–3-42 Service Log, Status branch, 3-29–3-30 shared diagnostic control panel (SDCP), 1-4, 3-3 Singleport mode, 4-31
options top-level menu messages, 3-11–3-16 Trellis Multipoint (TMp), 3-45 Troubleshooting, B-1–B-5
Dial Line, 4-50–4-52 DTE Dialer, 4-41–4-45 DTE Interface, 4-33–4-40 Leased Line, 4-53–4-57 Line Dialer, 4-46–4-49 Misc, 4-66–4-68 Security, 4-68 Test, 4-64–4-65 V.42/MNP/Buffer, 4-58–4-63 singleport modem, 1-2, 1-7
United States government requirements, 1-11–1-12 UNIX dial, 2-11, 4-2, 4-33
V.25bis dialing commands and response, D-1–D-8 V.34, modulation, 1-9, 1-10 V.34 modulation, 3-25
model 3921Plus, 1-4 soft straps. See configuration options software download, 3-42–3-49 speaker, 3-36 specifications, technical, 1-13–1-14 standalone
dial line, 5-17 leased lines, 1-10, 5-17 quick display, 3-15 V.42 error control, 4-58 V.42/MNP/Buffer configuration options group, 4-58 V.42bis data compression, 4-59 VF, 5-3, 5-9
multiport modem, 1-2 singleport modem,, 1-2 Status branch, 3-10, 3-17–3-30 status indicators (LEDs), 3-3–3-6 straps. See configuration options SubHS (Sub-Network Health and Status) branch, 3-10,
connection, 2-5–2-6, B-4–B-5 data rate, 5-25 interface requirements, 1-14 parameters, 1-7, 3-51 pin assignments, C-3 rates, 5-17 status, 3-20–3-23 VF Thresholds, update, 3-51–3-54
3-64–3-65 synchronous operation, 2-11, 4-2, 4-13, 4-33
Index-4 November 1996 3920-A2-GN31-30
Talk/Data · configuration options · weight, 1-14
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| The modem did not pass the power-up self-test. | Contact your service representative. | p.217 | |
| The power LED does not light or the LCD does not display information. | Make sure the modem’s ON/OFF switch is in the ON position. Make sure the power supply is connected to the dc power receptacle on the modem. If the Power LED and/or LCD do not operate, contact your service representative. | p.217 | |
| A problem is suspected after the power-up self-test. | Perform a self-test via the modem’s DCP or type AT&T9 if using AT commands. Perform a local analog loopback with a Pattern test. If the modem consistently registers errors, contact your service representative. If the modem passes the above tests and a problem still exists, then the problem is probably not with your modem. | p.217 | |
| The modems do not train-up on leased lines. | Verify that the correct cabling is used for your application. Refer to Chapter 2, Modem Installation. Verify that one modem is configured for Answer mode and the other is configured for Originate mode. (For TMp operation one modem must be configured as a control modem and the other as a tributary modem.) Verify that both modems are using the same modulation scheme. Verify that both modems are configured for the appropriate leased-line mode. For example, if you have a 4-wire leased line, then the modems must be configured for 4-wire operation. | p.218 | |
| The dial backup line is present, but the modems cannot connect. | Verify that the correct telephone number for the remote modem is stored in directory location 1. Verify that both modems have the Auto Dial Backup configuration option set to Enable. Refer to Leased Line in Chapter 4. Call the answering modem with a handset and verify that the modem’s answer tone is transmitted. | p.218 | |
| The modem does not switch back to leased-line operation. | Verify that the Auto Dial Standby configuration option is enabled. Refer to Leased Line in Chapter 4. | p.218 | |
| The modem does not accept or echo back AT commands. | Verify that the cable between the Async port of the DTE and the modem is a standard RS-232 cable. (Null modem cables, also known as crossover cables, do not work in this application.) Verify that the Command Character Echo configuration option is enabled. Refer to DTE Dialer in Chapter 4. Verify that the DTE Dialer Type configuration option is set to AT. Refer to DTE Dialer in Chapter 4. Verify that the Result Codes configuration option is enabled. Refer to DTE Dialer in Chapter 4. Reload the Async Dial factory configuration area to guarantee that all configuration options are returned to their proper setting. Make sure that all AT commands are terminated with a carriage return. Verify that the Carriage Return Character configuration option matches what is used by the DTE. Refer to DTE Dialer in Chapter 4. Verify that the DTE has a valid character format. Valid format consists of 8 data bits with no parity or 7 data bits with even, odd, mark or space parity. Verify that the DTE’s data rate is supported by the modem. Refer to the Async DTE Rate configuration option in the DTE Interface section of Chapter 4. If using a PC, verify that the modem is attached to the correct communications port. | p.219 | |
| The modem does not receive a dial tone. | Attach a telephone directly to the telephone line to verify that a dial tone exists. Make sure the VF line is connected to the modem’s rear jack labeled DIAL. | p.220 | |
| The modem does not go off-hook and answer an incoming call. | Verify that the Auto Answer Ring Count configuration option is set to a value other than 0 (disable). Refer to Line Dialer in Chapter 4. Verify that the DTE is providing DTR to the modem. If the DTE does not provide DTR to the modem, verify that the modem’s DTR Action configuration option is set for Ignore. Refer to DTE Interface in Chapter 4. Verify that all cables are attached to the correct connectors on the rear of the modem. | p.220 | |
| The modem goes off-hook, answers, but does not connect. | Perform a Local Analog Loopback test and verify that data entered at the DTE is echoed back to the DTE. Verify that the originating modem is compatible with your receiving modem. Verify that the originating modem recognizes your modem’s answer tone. Verify that the originating modem supports your modem’s modulation schemes. The 392xPlus modem recognizes CCITT V.34, V.32bis, V.32, V.22bis, V.22, V.21, Bell 212A, and Bell 103J. The 392xPlus modem does not support other vendors’ proprietary modulation schemes. Force your modem to operate at the same modulation scheme as the originating modem to see if they connect. | p.220 | |
| The Originate Mode does not function properly. | Verify that the modem’s DTE Dialer Type configuration option is set to the correct setting: either AT, DTR Dialing, V.25bis Async, V.25bis Bisync, or V.25bis HDLC. Refer to DTE Dialer in Chapter 4. | p.220 | |
| The modem does not go off-hook and begin dialing. | If using AT Dialing, refer to Table B-4, Modem — DTE Connection. If using DTR Dialing, verify the telephone number stored in directory location 1, and verify that the DTE is raising DTR from Off to ON to initiate a dial. If using V.25bis Async, verify that the correct character format is set to 7 data bits with even parity and 1 stop bit, and the carriage return and line feed are used as command terminators. If using V.25bis Bisync, verify that the correct character format uses two synchronous control characters and a start-of-text control character before the text block, and an end-of-text control character after the text block. If using V.25bis HDLC, verify that the character format uses flag, address, and control characters before the text block and a frame sequence check and flag after the text block. | p.220 | |
| The modem dials but does not connect. | If the modem is operating behind a PBX, determine if a 9 and comma are needed before the telephone number. Verify whether Tone or Pulse dialing is needed. Verify that both modems are configured the same in regard to Error Control. Try calling in Buffer mode. If both modems use V.32bis or V.32 modulation, try setting the modem’s V.32bis Train configuration option to Long. | p.220 | |
| Intermittent disconnects, high error rates, or excessive retransmissions occur. | Perform an End-to-End test. Refer to Pattern located in the Test Branch section of Chapter 3. | p.221 | |
| The modem establishes and then disconnects the call. | You may have a poor VF connection. Try dialing again. The remote modem may have encountered an error control (EC) disconnect. If the modems cannot negotiate EC, then a disconnect occurs. The remote modem may be in a forced Error Control mode (disconnect if there is no error control). Reconfigure your modem to V.42/MNP or Buffer and try again. Check the LCD to determine the reason for the disconnect. Perform a Local Analog Loopback test. | p.221 | |
| High error rates occur when running a local loopback or self-test. | Incoming rings can cause data errors during a loopback test. Abort the test, disconnect the modular VF cord, and restart the test. | p.221 | |
| The data is scrambled. | Verify that the character format (data bits, parity, and stop bits) is set to the same value in both modems. | p.221 | |
| Data is missing during a transfer. | Verify that you are using the same method of flow control for both the modem and the DTE. If using XON/XOFF flow control, verify that the modem’s parity matches the DTE’s parity. | p.221 | |
| The MUX configuration option does not appear under DTE Interface. | The Dial Access Security feature is enabled. Verify that both the Answer and Originate security options are disabled. Refer to sections Set Answer Sec and Set Orig Sec in Chapter 6. The Dial Line Rate or LeasedLine Rate configuration option is set to an invalid modulation. Refer to the Dial Line or Leased Line configuration option in the Multiport Mode section of Chapter 4 for the valid rates. | p.221 |