COMSPHERE 3900 SERIES MODEMS MODELS 3910 AND 3911 POINT-TO-POINT/MULTIPOINT

INSTALLATION AND OPERATION MANUAL

Document No. 3910-A2-GN32-30

November 1996

Page 2 of the Paradyne 3910 user manual — Trademarks
Page 2 · click to enlarge
Page 2

COMSPHERE 3900 Series Modems Models 3910 and 3911 Point-to-Point/Multipoint Installation and Operation Manual 3910-A2-GN32-30

4th Edition (November 1996)

Changes and enhancements to the product and to the information herein will be documented and issued as a new release to this manual.

For the 3900 Series standalone modems, the Universal Service Order Code (USOC) for Permissive mode is RJ11C. The Canadian equivalent to RJ11C is CA11A. For 3900 Series carrier-mounted modems, the USOC for Permissive mode is RJ21X. The Canadian equivalent to RJ21X is CA21A.

FCC Registration numberSee label on modem Ringer Equivalence number (REN): See label on modem
Model 3910 Canadian Certification numberSee label on modem Canadian DOC Load number: See label on modem

Model 3911 Canadian Certification number: See label on modem Canadian DOC Load number: See label on modem

Warranty, Sales, and Service Information

Contact your sales or service representative directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, or training, use one of the following methods:

  • Via the Internet: V isit the Paradyne World W ide W eb site at <a href="http://www" rel="nofollow noopener" target="_blank">http://www</a> .<a href="http://paradyne.com" rel="nofollow noopener" target="_blank">paradyne.com</a>
  • V ia T elephone: Call our automated call system to receive current information via fax or to speak with a company representative.

— Within the U.S.A., call 1-800-870-2221 — International, call 813-530-2340

Trademarks

All products and services mentioned herein are the trademarks, service marks, registered trademarks or registered service marks of their respective owners.

Printed on recycled paper

COPYRIGHT 1996 Paradyne Corporation. All rights reserved.

This publication is protected by federal copyright law. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mechanical, magnetic, manual or otherwise, or disclosed to third parties without the express written permission of Paradyne Corporation, 8545 126th Avenue North, P.O. Box 2826, Largo, Florida 33779-2826.

Paradyne Corporation makes no representation or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. Further, Paradyne Corporation reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation of Paradyne Corporation to notify any person of such revision or changes.

A November 1996 3910-A2-GN32-30

Page 3 of the Paradyne 3910 user manual — Important Safety Instructions
Page 3 · click to enlarge
Page 3

Important Safety Instructions

1. Read and follow all warning notices and instructions marked on the product or included in the manual.
2. This product is intended to be used with a three-wire grounding type plug – a plug which has a grounding pin. This is a safety feature. Equipment grounding is vital to ensure safe operation. Do not defeat the purpose of the grounding type plug by modifying the plug or using an adaptor.

Prior to installation, use an outlet tester or a voltmeter to check the ac receptacle for the presence of earth ground. If the receptacle is not properly grounded, the installation must not continue until a qualified electrician has corrected the problem.

If a three-wire grounding type power source is not available, consult a qualified electrician to determine another method of grounding the equipment.

3. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.
4. Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord.
5. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel.
6. General purpose cables are provided with this product. Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer.
7. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.
8. A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate buildings are interconnected , the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products.

In addition, if the equipment is to be used with telecommunications circuits, take the following precautions:

– Never install telephone wiring during a lightning storm. – Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. – Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. – Use caution when installing or modifying telephone lines. – Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning. – Do not use the telephone to report a gas leak in the vicinity of the leak.

B 3910-A2-GN32-30 November 1996

Safety Instructions

Page 4 of the Paradyne 3910 user manual — Notices
Page 4 · click to enlarge
Page 4

Notices

C November 1996 3910-A2-GN32-30

·

Page 8 of the Paradyne 3910 user manual — List of Figures
Page 8 · click to enlarge
Page 8

List of Figures

1-1 Model 3910 1-3 1-2 Model 3911 1-4 2-1 Model 3910 Rear Panel and Power Supply 2-3 2-2 Installing a Model 3911 Modem 2-10 2-3 Circuit Pack Lock 2-11 3-1 Model 3910 DCP 3-3 3-2 Optional SDCP, Model 3911 Faceplate, and Optional SDU 3-4 3-3 391x Series LCD and Keypad 3-6 3-4 Local Analog Loopback 3-48 3-5 Remote Digital Loopback 3-49 3-6 Local Digital Loopback 3-50 3-7 Pattern Test and Local Analog Loopback Test 3-51 3-8 Pattern Test and Digital Loopback Test 3-52 3-9 End-to-End Pattern Test 3-52 3-10 Dial Backup 3-58 4-1 DCP Configuration Process 4-2 4-2 AT Command Configuration Process 4-3 C-1 VF Pin Orientation C-3 C-2 Wiring Diagram — “Y” Cable for External Telephone C-4 C-3 Wiring Diagram — 8-Position to 6-Position Crossover Cable C-5 C-4 Wiring Diagram — 25-Pin Crossover Cable C-6 G-1 Sample Configuration — Point-to-Point G-2 G-2 Sample Configuration — Multipoint G-3 G-3 Sample Configuration — Point-to-Point with Automatic Dial Backup G-4 G-4 Sample Configuration — Point-to-Point with Network Management G-5 G-5 Sample Configuration — Carrier with Network Management G-6 G-6 Sample Configuration — Extended Multipoint G-7 G-7 Sample Configuration — Extended Diagnostics G-9

iv November 1996 3910-A2-GN32-30

Figure Page

Page 9 of the Paradyne 3910 user manual — List of Tables
Page 9 · click to enlarge
Page 9

List of Tables

1-1 3-1 Model 3910 and Model 3911 DCP LEDs 3-5 3-1 SDCP LEDs 3-6 3-3 Top-Level Menu Status 3-9 3-4 Common Operational Messages 3-12 3-5 Dial Access Security Messages 3-13 3-6 Health and Status Messages 3-17 3-7 Backup Status Screens 3-23 3-8 Valid Ranges for VF Thresholds 3-45 3-9 Valid Dial Command Modifiers 3-61 4-1 DTE Interface Configuration Options 4-10 4-2 DTE Dialer Configuration Options 4-20 4-3 Line Dialer Configuration Options 4-25 4-4 Dial Line Configuration Options 4-30 4-5 Leased Line Configuration Options 4-33 4-6 V.42/MNP/Buffer Configuration Options 4-39 4-7 Test Configuration Options 4-46 4-8 Miscellaneous Configuration Options 4-48 5-1 Result Codes 5-3 5-2 391x Series AT Commands 5-5 5-3 391x Series S-Registers 5-15 6-1 Edit Password Table Group Options 6-8 6-2 Set Answer Security Group Options 6-10 6-3 Set Originate Security Group Options 6-11 6-4 Security Configuration Options 6-14 6-5 Security Database Table Using VF-Side Passwords 6-18 6-6 Security Database Table Using DTE-Side Passwords 6-18 6-7 Security Database Table Using Both VF-Side and DTE-Side Passwords 6-19 B-1 Modem Health B-1 B-2 Leased-Line Operation B-2 B-3 Dial Backup Operation B-2 B-4 Modem — DTE Connection B-3 B-5 Modem — VF Connection B-4 B-6 Online Operation B-5 C-1 EIA-232-D Pin Assignments C-2 C-2 VF Connector Pin Assignments C-3 D-1 V.25bis Commands D-7

v 3910-A2-GN32-30 November 1996

Table of Contents · Table Page

Page 10 of the Paradyne 3910 user manual — List of Tables
Page 10 · click to enlarge
Page 10

D-2 V.25bis Response Messages D-8 E-1 ASCII Characters E-1 F-1 Factory Default Configuration Options F-2

vi November 1996 3910-A2-GN32-30

Table Page

Page 11 of the Paradyne 3910 user manual — How to Use this Manual
Page 11 · click to enlarge
Page 11

Preface

Objectives and Reader Assumptions

This manual describes how to install and operate the COMSPHERE 391x Series standalone and carrier-mounted modems. This manual assumes that you have a basic understanding of modems and their operation.

How to Use this Manual

Chapter 1 provides technical specifications, information about the 391x Series modems’ features, and the government requirements for using these modems.

Chapter 2 provides instructions for installing the 391x Series modems.

Chapter 3 provides the information required to operate the Model 3910 using the diagnostic control panel and the Model 3911 using the COMSPHERE 3000 Series Carrier’s shared diagnostic control panel (SDCP).

Chapter 4 provides the information required to set configuration options in the 391x Series modems using the modem’s diagnostic control panel.

Chapter 5 provides instructions for displaying and changing AT commands and S-Registers.

Chapter 6 provides instructions for using the Dial Access Security feature.

Appendix A provides a menu tree for the 391x Series modems.

Appendix B provides instructions for performing diagnostic tests when data communication problems occur.

Appendix C provides EIA-232-D and VF TELCO pin assignments.

Appendix D provides V.25bis dialing information.

Appendix E provides an ASCII translation chart.

Appendix F provides a list of all default configuration options available for the factory preset configurations.

Appendix G provides diagrams of sample configurations for the 391x Series modems.

Appendix H provides an equipment list for the 391x Series modems.

The Glossary provides a description of terms used throughout this manual.

vii 3910-A2-GN32-30 November 1996

Page 12 of the Paradyne 3910 user manual — Related Documents
Page 12 · click to enlarge
Page 12

Related Documents

3000-A2-GA31 COMSPHERE 3000 Series Carrier, Installation Manual

3610-A2-GZ45 3600 Hubbing Device Feature Number 3600-F3-300, Installation Instructions

3910-A2-GK41 COMSPHERE 3900 Series Modems, Models 3910 and 3911, Installation Instructions

Call your sales representative to order additional product documentation.

viii November 1996 3910-A2-GN32-30

Page 13 of the Paradyne 3910 user manual — Features
Page 13 · click to enlarge
Page 13

Introduction

Overview 1-1 Features 1-1 Multipoint Applications 1-2 Leased Backup Applications 1-2 COMSPHERE 391x Series Models 1-2 Standalone Model 3910 4-Wire/2-Wire Modem 1-3 Carrier-Mounted Model 3911 4-Wire/2-Wire Modem 1-4 Government Requirements and Equipment Return 1-5 United States 1-5 Canada 1-7 Technical Specifications 1-8

Overview

The COMSPHERE 391x Series modems, a new generation of full-feature, high-speed modems, offer reliable asynchronous and synchronous operation over leased-line or dial networks. The 391x Series modems’ unique software defineability allows for the addition of future enhancements, whether it is installing new features or firmware upgrades.

The modem’s compatibility with a number of dialing methods and protocols, such as asynchronous AT commands, CCITT V.25bis dialing, and the user-friendly diagnostic control panel (DCP), permits the 391x Series modem to be used in a variety of applications and environments while also allowing control over modem configuration, dialing, and diagnostics. The 391x Series modems offer preset factory configurations containing the most often used modem settings.

Features

The 391x Series modems have a wide variety of features.

  • Four-wire/two-wire point-to-point or four-wire multipoint operation.
  • Four-wire/two-wire leased-line modulations: V.32 terbo (19200 and 16800 bps), V.32bis (14400, 12000, 9600, 7200, and 4800 bps), V.32 (9600 and 4800 bps), Paradyne Point-to-Point Diagnostic (1200, 2400 bps) , Trellis Multipoint (19200, 14400, 9600, 7200, 4800, and 2400 bps), V.22bis (2400 bps), V.27bis (4800 and 2400 bps), V.33 (14400 and 12000 bps), and V.29 (9600, 7200, and 4800 bps).
  • Dial-line modulations: V.32 terbo (19200 and 16800 bps), V.32bis (14400, 12000, 9600, 7200, and 4800 bps), V.32 (9600 and 4800 bps), Paradyne Point-to-Point Diagnostic (1200, 2400 bps), V.22bis (2400 bps), V.22 (1200 bps), V.23 (1200 and 600 bps), V.21 (300 bps), Bell 212A (1200 bps), and Bell 103J (300 bps).
  • Channel adaptive T rellis-Coded Modulation, Paradyne’ s advanced T rellis-Coded transparent forward error correction for Trellis multipoint and high-speed point-to-point applications.
Page 14 of the Paradyne 3910 user manual — COMSPHERE 391x Series Models
Page 14 · click to enlarge
Page 14
  • Mixed inbound rates for multipoint applications.
  • Convenient migration to new or optional features through software downloading.
  • Extended data circuits with diagnostics.
  • Network management system (NMS) support through the COMSPHERE 6800 or 6700 Series NMS using Advanced Diagnostic protocol (ADp).
  • Complement of self-tests, local and remote loopbacks.
  • CCITT V .42bis and MNP Class 5 data compression.
  • Virtual error free data integrity with CCITT V.42 and MNP Level 4 error control.
  • Dial access security .
  • Automatic and manual backup with standby capabilities for 4-wire/2-wire leased-line applications. (The backup facility may be either a 2-wire dial line or a 2-wire leased line.)

Multipoint Applications

In multipoint applications, leased-line circuits are used for time sharing the same front-end processor (FEP) port with multiple remote locations. The FEP (via the control modem) regulates traffic on the line by continuously polling the tributary DTE(s) in a predefined sequence. Only one tributary can communicate with the control modem at a given time. Modems configured for Trellis Multipoint (TMp) cannot be used in a point-to-point, constant carrier application. (Refer to the Leased Line section in Chapter 4 for configuration options.)

Leased Backup Applications

In leased backup applications, a 2-wire leased line is used as the backup facility instead of the normal 2-wire dial line. Plug the leased line into the jack labeled DIAL on the rear panel of the modem (see Figure 2-1 in Chapter 2), and enable the Dual_Leased_Ln configuration option. (Refer to the Leased Line section in Chapter 4 for configuration options.) Except for dialing, ring indication, and call progression functions, you control the backup function as if it were a normal dial backup.

COMSPHERE 391x Series Models

The 391x Series family is available in two models: the Model 3910, a 4-wire/2-wire standalone modem, and the Model 3911, a carrier-mounted version of the standalone unit. Both models offer a variety of modulation schemes and network enhancements while still providing reliable, high-speed data transmission using the latest in modem technology.

Page 15 of the Paradyne 3910 user manual — Carrier-Mounted Model 3911 4-Wire/2-Wire Modem
Page 15 · click to enlarge
Page 15

Standalone Model 3910 4-Wire/2-Wire Modem

The standalone Model 3910 modem (Figure 1-1) is capable of either 4-wire/2-wire leased-line or dial operation. The modem is controlled using either AT commands or the diagnostic control panel (DCP). The DCP consists of a liquid crystal display (LCD), three function keys, four directional keys, and a row of 13 LED status indicators. For a better understanding of DCP operation, refer to Chapter 3, DCP Operation.

Paradyne 3910 — Standalone Model 3910 4-Wire/2-Wire Modem diagram (page 15)
Fig. 1 · Standalone Model 3910 4-Wire/2-Wire Modem

LEASED

Figure 1-1. Model 3910

The rear of the modem contains an ON/OFF power switch, a low voltage dc power connector, an 8-pin modular connector (LEASED) for leased-line connection, an 8-pin modular connector (DIAL) for dial-line or leased-line backup, a 4-pin modular connector (NMS) for network management, and a DB-25-S DTE connector.

Carrier-Mounted Model 3911 4-Wire/2-Wire Modem

The carrier-mounted Model 3911 modem (Figure 1-2) is capable of either 4-wire/2-wire leased-line or dial operation and installs into a COMSPHERE 3000 Series Carrier. The

Introduction · 496-14160-03

Page 16 of the Paradyne 3910 user manual — BACK CONNECTOR
Page 16 · click to enlarge
Page 16

Model 3911’s faceplate has 16 LED status indicators for displaying modem activity and an audio speaker jack for the carrier’s optional speaker.

The Model 3911 modem’s rear has two edge card connectors that mount into a connector plate located on the rear of the carrier. This connector plate has two DB-25-S connectors, one providing an EIA-232-D DTE interface and one for future functionality.

FACEPLATE

Paradyne 3910 — FACEPLATE diagram (page 16)
Fig. 2

BACK CONNECTOR

PLATE

EIA232/V.24 CONNECTOR

RS366A/V.25 (3800) EIA232/V.24

GROUNDING

TAB

FUTURE

V.35 (3600/3500)

USE

Figure 1-2. Model 3911

The Model 3911 derives ac power from the COMSPHERE 3000 Series Carrier’s backplane, which is a common bus to all devices installed in the carrier. The user interface to any Model 3911 is through the shared diagnostic control panel (SDCP), an optional feature which operates in a

496-14178b

Page 17 of the Paradyne 3910 user manual — United States
Page 17 · click to enlarge
Page 17

manner similar to the DCP on the Model 3910. For a better understanding of DCP operation, refer to Chapter 3, DCP Operation.

The COMSPHERE 3000 Series Carrier has a total of 17 slots. The first slot, Slot 0, is reserved for the shared diagnostic unit (SDU) while the remaining 16 slots can house up to 16 Model 3911 modems, or a combination of Model 3911 modems and other units. For more details on the COMSPHERE 3000 Series Carrier, refer to the COMSPHERE 3000 Series Carrier, Installation Manual.

Government Requirements and Equipment Return

Certain governments require that instructions pertaining to modem connection to the public switched telephone network be included in the installation and operation manual. Specific instructions are listed in the following sections.

United States

1. This equipment complies with Part 68 of the FCC rules. On the equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. The label is located on the bottom of the Model 3910 modem. This label is located on the Model 391 1’ s circuit card assembly . If requested, this information must be provided to the telephone company.
2. Page A of this manual contains the Universal Service Order Codes (USOC) associated with the services on which the equipment is to be connected.
3. An FCC compliant telephone cord and modular plug is provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant. See Installation Instructions for details.

4. The ringer equivalence (REN) is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the telephone company to determine the maximum RENs for the calling area.

5. If the 391x Series modem causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary .
6. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service.

Introduction

Page 18 of the Paradyne 3910 user manual — Introduction
Page 18 · click to enlarge
Page 18
7. If you experience trouble with this equipment, please contact your sales or service representative (as appropriate) for repair or warranty information. If the product needs to be returned to the company service center for repair, contact them directly for return instructions using one of the following methods:
  • Via the Internet: V isit the Paradyne World W ide W eb site at <a href="http://www" rel="nofollow noopener" target="_blank">http://www</a> .<a href="http://paradyne.com" rel="nofollow noopener" target="_blank">paradyne.com</a>
  • V ia T elephone: Call our automated call system to receive current information via fax or to speak with a company representative.

— Within the U.S.A., call 1-800-870-2221

— International, call 813-530-2340

If the trouble is causing harm to the telephone network, the telephone company may request that you remove the equipment from the network until the problem is resolved.

8. The user is not authorized to repair or modify the equipment.
9. This equipment cannot be used on public coin service provided by the telephone company. Connection to Party Line Service is subject to state tariffs. (Contact the state public utility commission, public service commission or corporation commission for information.)
Page 19 of the Paradyne 3910 user manual — CAUTION
Page 19 · click to enlarge
Page 19

Canada

The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.

Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone line and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.

CAUTION

Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

The Load Number is labeled on the equipment. The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all devices does not exceed 100.

If your equipment is in need of repair, refer to the procedure in the Government Requirements and Equipment Return section earlier in this chapter.

Introduction

Page 20 of the Paradyne 3910 user manual — DOC
Page 20 · click to enlarge
Page 20

Technical Specifications

Table 1-1 shows the technical specifications for the 391x Series modems.

(1 of 3) Technical Specifications for 391x Series Modems

APPROVALS

FCC Part 15 Class A

FCC Part 68 Registration Number(See label on modem)

UL

Model 3910 Listed to UL 1950

COMSPHERE 3000 Series Carrier Recognized to UL 1950

CSA

Model 3910 Certified to CSA C22.2 No. 950-M89

COMSPHERE 3000 Series Carrier Certified as a component to CSA C22.2 No. 950-M89

DOC

Model 3910 Certification Number(See label on modem)
Model 3911 Certification Number(See label on modem)

COMPATIBILITY Leased-Line Modulations:

Paradyne V.32 terbo (19200, 16800 bps) CCITT V.32bis (14400, 12000, 9600, 7200, 4800 bps) CCITT V.32 (9600, 4800 bps) Paradyne Trellis Multipoint (19200, 14400, 9600, 7200, 4800,

2400 bps) CCITT V.22bis (2400 bps) CCITT V.27bis (4800, 2400 bps) CCITT V.33 (14400, 12000 bps) CCITT V.29 (9600, 7200, 4800 bps) Paradyne Point-to-Point Diagnostic (1200, 2400 bps)

Dial-Line Modulations:

Paradyne V.32 terbo (19200, 16800 bps) CCITT V.32bis (14400, 12000, 9600, 7200, 4800 bps) CCITT V.32 (9600, 4800 bps) CCITT V.22bis (2400 bps) CCITT V.22 (1200 bps) CCITT V.23 (1200, 600 bps) CCITT V.21 (300 bps) Bell 212A (1200 bps) Bell 103J (300 bps) Paradyne Point-to-Point Diagnostic (1200, 2400 bps)

Table 1-1 · Specifications Description

Page 21 of the Paradyne 3910 user manual — TELEPHONE INTERFACE
Page 21 · click to enlarge
Page 21

(2 of 3) Technical Specifications for 391x Series Modems

ENVIRONMENT

Operating Temperature 32°F (0°C) to 122°F (50°C)

Relative Humidity 5% to 90% (noncondensing)

Shock and Vibration Withstands normal shipping

Storage Temperature –4°F (–20°C) to 158°F (70°C)

DTE INTERFACE

25-pin D-subminiature connector EIA-232-D/CCITT V.24

MODEL 3910 POWER SUPPL Y AC POWER REQUIREMENTS

100 to 250 Vac, 50 to 60 Hz

POWER CONSUMPTION

Model 3910 6 watts (typical, including power supply, speaker off)

Model 3911 4 watts (typical, each card) (Speaker consumption is approximately 1 watt at high volume.)

DIMENSIONS

Weight 2.5 pounds (1.14 kg) Model 3910 (without power supply) 1.0 pounds (0.45 kg) Model 3911

Height 2.1 inches (5.4 cm) Model 3910 7.1 inches (18.1 cm) Model 3911

Width 7.6 inches (19.4 cm) Model 3910 0.9 inches (2.3 cm) Model 3911

Depth 12.1 inches (30.8 cm) Model 3910 13.4 inches (34.0 cm) Model 3911

TRANSMIT LEVEL

Leased Line (North America) 0 through –15 dBm (in 1 dBm decrements) Factory default is 0 dBm

Leased Line (All Other Countries) 0 through –15 dBm (in 1 dBm decrements) Factory default is country dependent

Dial Line (North America) –10 through –32 dBm (in 1 dBm decrements) Factory default is Permissive (–9 dBm)

Dial Line (All Other Countries) Level setting is not accessible to the user Factory default is country dependent

TELEPHONE INTERFACE

Leased-Line Connectivity JM8 (Model 3910) 50-pin mass termination (Model 3911)

Dial-Line Connectivity RJ11C Permissive RJ21X Permissive 50-pin connector (Model 3911)

Introduction · Table 1-1 · Specifications Description

Page 22 of the Paradyne 3910 user manual — ERROR CONTROL CCITT V.42 MNP 4-2
Page 22 · click to enlarge
Page 22

(3 of 3) Technical Specifications for 391x Series Modems

DAT A RA TES

Leased Line 19200, 16800, 14400, 12000, 9600, 7200, 4800, 2400 1200 bps

Dial Line 19200, 16800, 14400, 12000, 9600, 7200, 4800, 2400, 1200, 600, 300 bps

ERROR CONTROL CCITT V.42 MNP 4-2

DATA COMPRESSION CCITT V.42bis MNP Class 5

Table 1-1 · Specifications Description

Page 23 of the Paradyne 3910 user manual — 391x Series Modem Package
Page 23 · click to enlarge
Page 23

Modem Installation

Overview 2-1 391x Series Modem Package 2-1 Customer-Supplied Equipment 2-2 Model 3910 Modem Installation 2-2 Connecting Cables to the Model 3910 Modems 2-3 DTE Connection 2-4 Model 3910 4-Wire/2-Wire Leased-Line Connection 2-4 Dial Network Connection 2-4 Model 3910 Dial Backup Connection 2-4 Model 3910 Leased Backup Connection 2-4 Network Management System Connection 2-5 Power Supply Connection 2-5 Modem Power-Up 2-5 Selecting Factory Configuration Options 2-6 Using the Diagnostic Control Panel (DCP) 2-6 Using AT Commands 2-7 Removing and Replacing Model 3910 Modems 2-9 Model 3911 Modem Installation 2-9 Removing and Replacing Model 3911 Modems 2-12

Overview

This chapter provides a list of equipment supplied with the modem as well as a list of customer supplied equipment. In addition, it describes how to install and remove the 391x Series modem, and how to select a factory preset configuration using either the DCP or AT command set.

391x Series Modem Package

After opening the modem’s package, check for damage and verify that the following items are present:

For the standalone model

  • Installation instructions
  • Model 3910 modem
  • Power supply
  • One 6-position, 4-wire modular cord
  • One 8-position, 8-wire modular cord
Page 24 of the Paradyne 3910 user manual — Model 3910 Modem Installation
Page 24 · click to enlarge
Page 24

For the carrier-mounted model

  • Installation instructions
  • Model 391 1 modem
  • Rear connector plate with two DB-25-S edge card connectors

If any hardware components are damaged, notify your service representative. Return equipment using the procedures described in the Government Requirements and Equipment Return section of Chapter 1.

Customer-Supplied Equipment

The following customer-supplied equipment is required to complete a data communications system using the Model 3910 modem:

  • A DTE with an available EIA-232-D serial port.
  • A standard EIA-232-D cable with a DB-25-P (plug) connector at one end to attach to the modem.
  • One of the following modular leased or dial network interfaces:

— JM8 for leased-line applications.

— RJ11C for dial permissive applications.

The following customer-supplied equipment is required for the installation of a Model 3911 modem:

  • A COMSPHERE 3000 Series Carrier.
  • A 50-pin mass termination cable.
  • One of the following modular or 50-pin leased or dial network interfaces:

— RJ11C for single line dial permissive applications.

— RJ21X for multiple line dial permissive applications.

— 66 punchdown block.

  • One Network Interface Module (NIM) for modems installed in Slots 1–8 and one NIM for modems installed in Slots 9–16 (required for dial-line applications).

For installation of the COMSPHERE 3000 Series Carrier into a cabinet, refer to the COMSPHERE 3000 Series Carrier, Installation Manual.

Model 3910 Modem Installation

Before installing your standalone modem, make sure your installation site is clean and well-ventilated. Allow space around the modem for installing cables and telephone cords, and make sure the modem is located within reach of the ac power outlet. The distance between your modem and DTE should be minimized if DTE data rates exceed 19,200 bps. Also, low capacitance cables may be necessary for speeds greater than 19,200 bps or distances greater than 50 feet.

Page 25 of the Paradyne 3910 user manual — 8-POSITION, 8-CONDUCTOR PLUG FOR LEASED-LINE
Page 25 · click to enlarge
Page 25

The rear panel of the Model 3910 modem (Figure 2-1) has the following switches and connectors:

  • An ON/OFF power switch.
  • An 8-pin DIN type power receptacle (PWR) for the dc power supply.
  • An 8-pin modular keyed jack (LEASED) for 4-wire/2-wire leased lines.
  • An 8-pin modular keyed jack (DIAL) for backup lines (2-wire dial or 2-wire leased).
  • A 4-pin modular jack for the (NMS) network management system connection.
  • A 25-pin DB-25-S receptacle for the DTE interface.

Connecting Cables to the Model 3910 Modems

Figure 2-1 shows how Model 3910 modems are connected to certain TELCO jack types using the appropriate cables. For pin assignments, refer to Appendix C.

Paradyne 3910 — Connecting Cables to the Model 3910 Modems diagram (page 25)
Fig. 3 · Connecting Cables to the Model 3910 Modems

8-POSITION, 8-CONDUCTOR PLUG FOR LEASED-LINE

NETWORK OPERATION

Figure 2-1. Model 3910 Rear Panel and Power Supply

Modem Installation

Page 26 of the Paradyne 3910 user manual — Model 3910 Leased Backup Connection
Page 26 · click to enlarge
Page 26

DTE Connection

Use the following procedures to connect the EIA-232-D cable from the modem to the DTE:

1. Make sure the modem’ s rear panel power switch is OFF .
2. Connect the DB-25-P (plug) connector on the cable to the DB-25-S (socket) connector labeled DTE (Figure 2-1) on the modem’ s rear panel. Use a small screwdriver to secure the cable to the modem.
3. Connect the DB-25-P connector on the cable to the DB-25-S connector on the DTE. Use a small screwdriver to secure the cable to the DTE.

Model 3910 4-Wire/2-Wire Leased-Line Connection

Use the following procedures to connect a Model 3910 to the leased-line network interface:

1. Insert the 8-position, 8-conductor modular plug into the jack labeled LEASED (Figure 2-1).
2. Insert the other end of the modular cord into the leased-line network interface.

Dial Network Connection

The telephone company provides the line termination jacks for the permissive service you request. Advance coordination with the telephone company is suggested when connecting the modem to telephone dial lines (PSTN).

In the Permissive mode, the modem’s transmit output level is fixed at –9 dBm. The telephone company assumes that the line loss is 3 dB and no compensation is provided for additional losses. A Permissive mode telephone line is usually terminated with a USOC RJ11C jack.

Model 3910 Dial Backup Connection

For the Model 3910, use the following procedures to connect the modem to the dial backup network interface:

1. Insert the 6-position, 4-conductor modular plug into the jack labeled DIAL (Figure 2-1).
2. Insert the other end of the modular cord into the dial network interface.

Model 3910 Leased Backup Connection

For the Model 3910, use the following procedures to connect the modem to the 2-wire leased backup network interface:

1. Insert the 8-position, 8 conductor modular plug into the jack labeled DIAL (Figure 2-1).
2. Insert the other end of the modular cord into the leased-line network interface.
Page 27 of the Paradyne 3910 user manual — F1
Page 27 · click to enlarge
Page 27

Network Management System Connection

For the Model 3910, use the following procedures to connect the modem to the network management system interface:

1. Insert the sub-miniature, 4-conductor modular plug of the 3600 Hubbing Device into the jack labeled NMS (Figure 2-1). Refer to Document Number, 3610-A2-GZ45, 3600 Hubbing Device Featur e Number 3600-F3-300, Installation Instructions , for a description of the 3600 Hubbing Device. Installation for the 3910 is the same as for the 3610 DSU.
2. Connect the 3600 Hubbing Device to the network management channel (Figure G-4 in Appendix G).

Power Supply Connection

Use the following procedures to connect the modem to an ac power outlet:

1. Make sure the modem’ s power switch is in the OFF position.
2. Insert the power supply’s 8-pin DIN connector into the modem’s rear panel dc power receptacle (Figure 2-1).
3. Connect the power supply to a grounded ac power outlet.

Modem Power-Up

Once your modem is properly connected to the power supply, leased and/or dial lines, and the DTE, press the modem’s rear panel power switch to the ON position. The modem begins a power-up self-test, in which all DCP LEDs light. This test takes several seconds to perform, and verifies the operation of most hardware components within the modem. If successful, the LCD displays Power on Selftst Passed and continues to the Top-Level menu screen.

Power On Selftst Passed

F1

F2 F3

If a failure occurs during the self-test, the LCD displays Power On Selftst Failed for several seconds. The LCD then displays the Top-Level menu screen with the message Power on Fail appearing on the top line of the LCD. Although a failure has occurred, the modem will attempt to operate. This allows you to activate a more thorough self-test using the Test branch. Refer to the Test section in Chapter 3.

Modem Installation

Page 28 of the Paradyne 3910 user manual — Using the Diagnostic Control Panel (DCP)
Page 28 · click to enlarge
Page 28

Selecting Factory Configuration Options

After the modem passes the power-up self-test, configure it for operation using one of the six factory preset configurations.

The 391x Series modems have six factory preset templates that contain the most commonly used configuration options (straps) for Synchronous Leased (Answer or Originate), Asynchronous Leased (Answer or Originate), Trellis Multipoint (Control or Tributary), Asynchronous Dial, Synchronous Dial, and UNIX Dial hardware network configurations. Your modem ships from the factory with the Synchronous Leased (Answer) default configuration options stored in memory. If Synchronous Leased (Originate), Asynchronous Leased (Answer or Originate), Trellis Multipoint (TMp) (Control or Tributary), Async Dial, Sync Dial, or UNIX Dial is more appropriate for your configuration, then you must change the factory setting using either the modem’s DCP or the AT command set as described in the following sections.

The purpose of having preset configurations is so that you can have a “head start” in getting your modem operating and reducing the amount of time required to configure your modem. For a better understanding of DCP operation and factory preset configuration options, refer to Chapter 4, DCP Configuration.

Using the Diagnostic Control Panel (DCP)

The DCP’s liquid crystal display (LCD) consists of two 16-character lines which display modem status, control functions, and configuration options as well as indicating your location in the Top-Level menu tree (Appendix A).

To change a factory template from the Sync Leased preset configuration using the DCP, perform the following steps:

1. Press the function key below Configure to select the Configure branch.

The LCD now displays Ld EditArea frm.

2. Press the key until Factory comes into view , then press the F1 key to display the factory preset configurations.

Factory preset configurations are Sync Leased, Async Leased, TMp (Trellis Multipoint), Async Dial, Sync Dial, and UNIX Dial. If Sync Leased or Async Leased is selected, you must choose either Answer or Originate mode. If TMp is selected, you must choose either Control or Trib (Tributary) mode.

3. Press the key until the appropriate factory preset template appears on the LCD, and press the corresponding function key to select your choice. (For certain factory templates you will also need to choose the appropriate mode.)
4. Choose Function appears and displays the Edit and Save functions.
5. Press the F3 key (Save) to save the new factory preset configuration to one of three configuration areas, Active (Saved), Customer 1 , or Customer 2 .

(These three configuration areas are nonvolatile memory locations. Active (Saved) contains the most recently saved changes to any configuration options. In the event of power loss, the modem retrieves these configuration options. Customer 1 and Customer 2 are user-defined configuration areas.)

The LCD now displays Sav EditArea to.

Page 29 of the Paradyne 3910 user manual — NOTE
Page 29 · click to enlarge
Page 29
6. Press the key until the appropriate configuration area appears on the LCD, then press the corresponding function key to select your choice. (Saving configuration options to the Active (Saved) configuration area automatically saves them to the Active (Operating) configuration area.) The LCD displays Command Complete .
7. The modem is now configured with the selected factory template. Press the key to return to the Top-Level menu.

Refer to Chapter 4, DCP Configuration, for more information regarding default factory configuration options.

Using AT Commands

When using AT commands, the following criteria must be met:

  • Make sure the asynchronous DTE’s communication software is configured for 10-bit character format (for example, 8 data bits, no parity, and 1 stop bit).
  • Make sure the DTE cable is attached to the DTE connector on the rear of the 391x Series modem and to the correct serial communications port on the asynchronous DTE.
  • Configure the modem for Async Dial, Async Leased, or UNIX Dial as described earlier in Using the DCP . To verify that the modem is connected and functioning properly, enter the following:

TYPE: AT

PRESSReturn (Enter)

The screen displays OK.

If the modem does not return OK, refer to Appendix B, Troubleshooting.

NOTE

If the factory preset configuration is something other than Async Dial, Async Leased, or UNIX Dial, you do not have AT command control. To regain AT command control, select, via the DCP, the Async Dial factory preset configuration as described earlier in Using the DCP.

Modem Installation

Page 30 of the Paradyne 3910 user manual — NOTE
Page 30 · click to enlarge
Page 30

To change a factory template using AT commands, perform the following steps. For more information on changing factory templates using AT commands, refer to Chapter 5, AT Command Set and S-Registers.

1. Use the AT&F&W command to load the appropriate factory configuration to the appropriate storage area. Enter the following:
TYPEAT&F y &W n
Wherey is one of the following Factory configurations:

0 for Async Dial 1 for Sync Dial 2 for Sync Leased (Answer) 3 for UNIX Dial 4 for Sync Leased (Originate) 5 for Async Leased (Answer) 6 for Async Leased (Originate) 7 for TMp (Control) 8 for TMp (Trib)

NOTE

Only &F0, &F3, &F5, and &F6 allow you to use AT commands after saving a factory configuration. Any other selection removes AT command control. The only way to return to AT command control is through the DCP as described earlier in Using the DCP.

Wheren is one of the following storage areas:

0 for Active (Saved) 1 for Customer 1 2 for Customer 2

NOTE

These three configuration areas are nonvolatile memory locations. Active (Saved) contains the most recently saved changes to any configuration options. In the event of power loss, the modem retrieves these configuration options. Customer 1 and Customer 2 are user-defined configuration areas.

PRESSReturn (Enter)
2. The selected factory configuration is saved.

To establish a connection with a remote modem, use the D (Dial) command. Refer to Chapter 5, AT Commands and S-Registers, for more on AT commands.

Page 31 of the Paradyne 3910 user manual — CAUTION
Page 31 · click to enlarge
Page 31

Removing and Replacing Model 3910 Modems

To remove and replace a Model 3910 modem, perform the following steps:

1. Make sure the modem is of fline, and press the modem’s rear panel power switch to the OFF position.
2. Disconnect the power cord from the ac power outlet, and then disconnect the dc power cable from the connector on the rear of the modem.
3. Disconnect the leased-line and dial modular cords from the modem’s rear panel.
4. Disconnect the DTE interface cable from the modem’s rear panel.

If the modem is to be removed for service, return it to the company using the procedures described in Government Requirements and Equipment Return in Chapter 1.

5. Install the replacement modem as described in the Model 3910 Modem Installation section of this chapter, and configure it the same way as the modem being replaced.

Model 3911 Modem Installation

CAUTION

If the Model 3911 is removed from the carrier, always use a ground strap when handling the modem. Always store the Model 3911 in an antistatic bag when it is removed from the carrier.

The Model 3911 is designed for installation in a COMSPHERE 3000 Series Carrier which supplies both the operating power and the leased and/or dial network connections. For additional information about the COMSPHERE 3000 Series Carrier, refer to the COMSPHERE 3000 Series Carrier, Installation Manual.

The COMSPHERE 3000 Series Carrier has 17 slots which can hold up to 16 modems and one shared diagnostic unit (SDU). The SDU is required when the modems in the carrier are controlled by an NMS, or when multiple carriers in a cabinet configuration are to be controlled by a single shared diagnostic control panel (SDCP). The SDCP of the COMSPHERE 3000 Series Carrier is the user interface to the Model 3911 modem. A single SDCP can control up to eight carriers containing up to 128 compatible modems.

The installation of a Model 3911 varies slightly if an SDCP is installed on the front of the carrier. To install a Model 3911 modem into the carrier without an SDCP, perform the following steps:

1. At the rear of the carrier , install the rear connector plate. Make sure the plate uses the same slot position as that intended for the modem.

Loosely fasten the plate. This allows for slight adjustments later when installing the modem.

Modem Installation

Page 32 of the Paradyne 3910 user manual — Modem Installation
Page 32 · click to enlarge
Page 32
Paradyne 3910 — Modem Installation diagram (page 32)
Fig. 4 · Modem Installation

Figure 2-2. Installing a Model 3911 Modem

2. At the front of the carrier, hold the modem vertically, with the latch on its faceplate in the open position, and insert it into the top and bottom card guides of one of the slots numbered 1–16 (Figure 2-2).

Slide the modem into the slot, aligning the modem with the rear connector plate, until the backplane connector and DTE connector seat firmly into the back of the carrier. The faceplate latch automatically closes as you push the modem into the carrier. To lock the modem into the carrier, press the faceplate latch until a “click” is heard.

3. If the carrier is ON, the Power LED on the faceplate of the 3911 lights. After several seconds the modem completes its power -up self-test, in which all faceplate LEDs light.

Return to the rear of the carrier and tighten the rear connector plate.

If the modem is to communicate with an installed SDCP, install the modem as described above and perform the following steps:

1. Press the Select key on the SDCP . The cursor appears in the carrier selection entry.
2. Press the F1 ( ) or F2 ( ) key until the carrier number you want appears on the LCD.

The carrier number selection has a range of 1 to 8 since a single SDCP can control a configuration of up to eight carriers. (This is only possible if the SDU is installed.)

3. Press the key to position the cursor on the slot selection entry.
4. Press the F1 ( ) or F2 ( ) key until the slot number you want (1–16) appears on the LCD.
Page 33 of the Paradyne 3910 user manual — Modem Installation
Page 33 · click to enlarge
Page 33
5. Press the Select key to place the SDCP in direct communication with the selected modem.

The LCD displays the Top-Level menu for the selected modem. In addition, the Front Panel LED on the modem’s faceplate and the OK LED on the SDCP light.

6. Once you have determined that the modem is installed properly and completed its power-up self-test, rotate the circuit pack lock until it covers the faceplate latch (Figure 2-3) and tighten the retention screw on the circuit pack lock. This prevents the modem from accidently being removed once it is installed in a carrier.
7. Configure the modem as described in the Selecting Factory Configuration Options section earlier in this chapter.
Paradyne 3910 — Modem Installation diagram (page 33)
Fig. 5 · Modem Installation

Figure 2-3. Circuit Pack Lock

Modem Installation

Page 34 of the Paradyne 3910 user manual — CAUTION
Page 34 · click to enlarge
Page 34

Removing and Replacing Model 3911 Modems

CAUTION

If the Model 3911 is removed from the carrier, always use a ground strap when handling the modem. Always store the Model 3911 in an antistatic bag when it is removed from the carrier.

It is not necessary to power down the carrier to remove and replace a Model 3911 modem. Perform the following steps:

1. Rotate the circuit pack lock until the release tab is exposed.
2. Press down on the release tab and pull the modem away from the carrier’ s backplane.
Page 35 of the Paradyne 3910 user manual — DCP Operation
Page 35 · click to enlarge
Page 35

DCP Operation

Overview 3-2 Diagnostic Control Panels 3-2 Model 3910 Diagnostic Control Panel 3-3 Model 3911 Faceplate and Shared Diagnostic Control Panel (SDCP) 3-3 . . . Status Indicators 3-4 Diagnostic Control Panel Operation 3-6 LCD Display 3-6 Hidden Choice Indicators 3-7 Other Indicators 3-7 Keypad 3-7 Menu Structure 3-8 Top-Level Menu Status and Operational Messages 3-9 Quick Configuration Display 3-14 Status Branch 3-15 Device Health and Status (DeviceHS) 3-16 VF 3-19 Identity 3-20 DTE 3-21 Backup 3-21 Options 3-23 Record 3-24 Configure Branch 3-25 Poll List Branch 3-25 Display 3-26 Clear 3-27 Change 3-27 Add 3-28 Acquire 3-29 Control Branch 3-30 Speaker 3-31 Reset 3-31 Data Stream 3-32 EIA LEDs 3-33 Make Busy/Remove Make Busy 3-34 Service Line/Disconnect Service Line 3-35 Download Software 3-35 Selecting Clone Remote 3-36 Clone Remote in Point-to-Point Configurations 3-36 Clone Remote in Broadcast Configurations 3-37 Clone Remote in Multipoint Configurations 3-38 Implementing a Clone Remote Operation 3-40 VF Thresholds Update 3-42 Test Branch 3-46 Abort 3-46 Self 3-47 Loc Analog Loop 3-48 Rem Digital Loop 3-49 Loc Digital Loop 3-50 Pattern 3-51 Sub-Network Health and Status Branch 3-53

Page 36 of the Paradyne 3910 user manual — Diagnostic Control Panels
Page 36 · click to enlarge
Page 36

Call Setup Branch 3-54 Dial 3-55 Disconnect 3-56 Answer 3-57 Dial Standby/Return to Dial 3-57 Change Directory 3-59 Entering Telephone Numbers and Dial Command Modifiers into

Directory Locations 3-60 Directory Status (Does Not Appear in North America) 3-61 Talk/Data Branch 3-62 Manual Dialing When the Remote Modem is Configured for

Auto-Answer 3-63 Manual Dialing When the Remote Modem is Configured for

Manual Answer 3-64 Security Branch 3-64 Remote Branch 3-65 Diagnostic Control Panel Access 3-69

Overview

This chapter describes how to use the diagnostic control panel (DCP) of the 391x Series modem. It also describes how to select and use each branch of the Top-Level menu tree.

Diagnostic Control Panels

There are two types of diagnostic control panels (DCP), the DCP on the standalone Model 3910 modems and the shared diagnostic control panel (SDCP), an optional feature, used with the Model 3911 installed into a COMSPHERE 3000 Series Carrier. Both DCPs have a two-line, 32-character liquid crystal display (LCD) and keypad through which Top-Level menu branches are accessed to perform the following:

  • Check modem status
  • Set up configuration options
  • Initiate diagnostic tests
  • Initiate and disconnect dial operations
  • Access remote modems through the local modem’ s DCP

The LCD displays the result of any command initiated using the DCP. Most of these operations can be performed from an attached asynchronous DTE using the AT command set.

Page 37 of the Paradyne 3910 user manual — Model 3911 Faceplate and Shared Diagnostic Control Panel (SDCP)
Page 37 · click to enlarge
Page 37

Model 3910 Diagnostic Control Panel

The diagnostic control panel (DCP) of the Model 3910 modem (Figure 3-1) contains status indicators, pushbutton-type keys, an LCD, and speaker grill.

F1 F2 F3

PWR ALRM CTS TXD LSD RXD TEST RATE

DIAG DIAL

SQ RTS DTR

105 106 103 109 108 142 COMSPHERE 3910

Figure 3-1. Model 3910 DCP

Model 3911 Faceplate and Shared Diagnostic Control Panel (SDCP)

The shared diagnostic control panel (SDCP), Figure 3-2, is used to manage carrier-mounted Model 3911 modems.

The faceplate of the Model 3911 contains status indicators that monitor the operation of the modem. After the SDCP is connected to the modem, the Front Panel indicator of the selected modem lights to show that the modem is connected.

DCP Operation · 496-14174-01

Page 38 of the Paradyne 3910 user manual — ERROR CORRECTION
Page 38 · click to enlarge
Page 38

Status Indicators

The 391x Series modems’ status indicators continuously provide information on the modem’s operating condition. All of the status indicators on the Model 3910 appear on the DCP (Figure 3-1), whereas the status indicators for the carrier-mounted Model 3911 are located on the Model 3911’s faceplate, the SDCP, and the SDU faceplate (Figure 3-2).

OK

RI

SQ

TXD

RXD

RTS

CTS

DSR

DTR

LSD

SDU

CARRIER SLOTS 1–16

SDU 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

F1 F2 F3

COMSPHERE 3000

OK Alarm BckUp Test EC

SELECT

KEY STATUS INDICATORS

KEYPAD LCD

OK Alarm BckUp Test EC

ERROR CORRECTION

NETWORK

DEVICE

ALARM

DIAL BACKUP

TEST MODE

Figure 3-2. Optional SDCP, Model 3911 Faceplate, and Optional SDU

Show 17 more labels / short text on this page
Status · Status · Pwr · Alrm · Alrm · Diag · In · Test · Diag · Out · Dial · Busy · Serv · Front Panel · Spkr · Select · 496-14175-01
Page 39 of the Paradyne 3910 user manual — DCP Operation
Page 39 · click to enlarge
Page 39

The standalone Model 3910 modem’s DCP has 13 light-emitting diodes (LEDs), and the carrier-mounted Model 3911 has 16 LEDs. These LEDs are listed and described in Table 3-1. LEDs specific to one model type have the appropriate model number shown in the table.

Table 3-1 Model 3910 and Model 3911 DCP LEDs

Pwr green Power has been applied to the modem.

Alrm red Flashing. A major alarm has been detected in a remote 391x Series modem. ON. A major alarm has been detected in the local modem. (For Health and Status alarm conditions, refer to Table 3-6 in the Device Health and Status (DeviceHS) section of this chapter.)

green The modem is receiving diagnostic communications (either a command or a status poll).

Test/142 yellow Flashing. The modem is involved in a firmware upgrade. Normal operation is not possible. ON. The modem is involved in a test. Normal operation is not possible. OFF. The modem is not involved in a test or firmware upgrade.

Dial yellow Flashing. The modem is attempting to establish a call over the dial network, or the modem is in Dial Standby mode. ON. The modem has established a dial connection. OFF. A dial connection does not exist.

green A ringing signal is being received.

yellow The modem is placed in a forced busy condition and is off-hook.

yellow The modem is connected to the carrier service line rather than the normally assigned network.

SQ yellow The receive telephone line signal is degraded or the modem’s data path has been blocked (SQ flashes).

TXD/103 green The modem is receiving data from the DTE to transmit. (ON equals space.)

RXD/104 green Data is being transferred to the DTE. (ON equals space.)

RTS/105 green RTS signal is ON.

CTS/106 green CTS signal is ON.

green DSR signal is ON.

DTR/108 green The DTE has turned ON DTR or the modem has forced DTR ON.

LSD/109 green The modem has detected a valid carrier signal and is capable of transferring data to the DTE.

yellow ON. The modem is connected at a data rate lower than the data rate it is configured for. OFF. The modem is connected at its configured data rate.

Front Panel (3911 only)

yellow The modem is connected to the carrier’s SDCP.

Show 8 more labels / short text on this page
DCP Operation · Label Color Indicates · Diag (3910 only) · RI/125 (3911 only) · Busy (3911 only) · Serv (3911 only) · DSR/107 (3911 only) · Rate (3910 only)
Page 40 of the Paradyne 3910 user manual — LCD Display
Page 40 · click to enlarge
Page 40

The SDCP LEDs are listed and described in Table 3-2.

Table 3-2 SDCP LEDs

OK green Power is ON and the modem is capable of operating.

Alarm red The modem has detected a problem with its operation. For example, the modem failed a self-test.

BckUp yellow The modem, originally configured for leased-line operation, is now operating on dial networks in a Dial Backup mode.

Test yellow The modem is involved in a test. Normal operation is not possible.

EC green The modem is in Error Control mode.

Diagnostic Control Panel Operation

The 391x Series modem’s diagnostic control panel (DCP) is the user interface to all functions used to configure and control the modem. In addition to the status LEDs, this interface includes the liquid crystal display (LCD) and keypad (Figure 3-3).

LCD T O P L INE HIDDEN CHOICE

INDICATOR

MOVES UP ONE LEVE L F ROM

RETURNS DISPLA Y T O TOP-LEVEL MENU

Leased:19.2 Status Configure

CURRENT

DISPLAY

F1

F2 F3

LEFT SCROLL

RIGHT SCROLL KEY

KEY

FUNCTION KEYS LCD BOTTO M L INE

Figure 3-3. 391x Series LCD and Keypad

LCD Display

The LCD consists of a top line and bottom line, with each displaying a maximum of 16 characters at a time. If more information is available on the LCD than what is currently displayed, an indicator appears in the top right or bottom right-hand corner of the LCD. Use the

or key to scroll in the indicated direction to display more selections onto the LCD.

Label Color Indicates

Page 41 of the Paradyne 3910 user manual — Keypad
Page 41 · click to enlarge
Page 41

The hidden choice indicators serve as an alert that other choices are available besides what is currently displaying on the LCD. These indicators appear as one of the following symbols:

Right Scroll Indicator >

The right scroll indicator appears when more choices are available to the right of what is currently displayed on the LCD.

The left/right scroll indicator appears when more choices are available to the left and right of what is currently displayed on the LCD.

Left Scroll Indicator

The left scroll indicator appears when more choices are available to the left of what is currently displayed on the LCD.

Other indicators may turn on depending on existing conditions, such as error detection, informational alerts, and warnings. These indicators appear on the top or bottom line of the LCD.

If the local 391x Series modem establishes a connection with the remote 391x Series modem via the Remote branch, then appears in the upper right corner of the LCD top line on both modems. For more information on the Remote Mode indicator, refer to Remote Branch in this chapter.

Out of Range Indicator

If an invalid threshold (out of range) is selected in the VF Threshold update process, then appears in the lower right corner of the LCD bottom line. For more information on the Out of Range indicator, refer to VF Threshold Update in this chapter.

Keypad

The DCP on the Model 3910 has seven keys while the optional SDCP of the COMSPHERE 3000 Series Carrier has eight keys. The additional key on the carrier is the Select key, used to connect the SDCP to a specific slot in the carrier.

The key returns you to the Top-Level menu display from anywhere in the menu tree.

Pressing while changing configuration options displays the message Save Straps? Yes No. If No is selected, changes made to configuration options are not saved and the Top-Level menu appears. If Yes is selected, then changes are saved to either Active (Saved), Customer 1, or Customer 2 configuration areas.

The key moves you up one level in the menu tree.

Use the and keys to move the viewing window left or right and to scroll the remaining branches and selections into view. A maximum of three selections can be displayed at one time.

Show 8 more labels / short text on this page
DCP Operation · Hidden Choice Indicators · Left/Right Scroll Indicator · Other Indicators · Remote Mode Indicator · Key · Key · and Keys
Page 42 of the Paradyne 3910 user manual — Menu Structure
Page 42 · click to enlarge
Page 42

These keys also allow you to move the cursor one character to the left or right on data entry displays; for example, to allow entry of one digit at a time.

F1 F2 F3 Keys

Function keys select the LCD choice that appears above the function key; they are labeled F1, F2, and F3. If a selection spans more than one function key, then any of those keys choose that selection.

Select Key (Model 3911 only)

The Select key appears on the optional SDCP of the COMSPHERE 3000 Series Carrier. It is used to connect the SDCP to a modem in a specific slot in the carrier.

Menu Structure

The menu tree is a hierarchical structure used to display functions that configure and control local and remote 391x Series modems. It is accessed via the DCP and is shown in Appendix A.

“Status” Displays the current status of the modem along with the data rate and the error control mode.

The menu tree contains the following branches:

Status — Used to monitor the current status of the VF line and DTE interface as well as view the identity of the modem.

Configure — Used to change and save the modem’s configuration options.

PList — (Poll List) Used to identify downstream modems in order to support multipoint health and status polling and multipoint link download broadcasting.

Control — Used to control the modem’s hardware and software functions.

Test — Used to begin and end various modem tests.

SubHS — (Sub-Network Health and Status) Used to display alarm conditions in downstream modems.

Call Setup — Used to dial, disconnect, and answer telephone calls as well as store up to 24 telephone numbers in directory locations.

Talk/Data — Used to switch the modem between Talk mode (the modem is disconnected from the VF line) and Data mode (the modem is connected to the VF line) when dialing via either the DCP or a telephone.

Security — Used to control the modem’s dial access security.

Remote — Used to access and control a remote 3900 Series modem.

Show 9 more labels / short text on this page
Status PList · Test · Call_Setup · Security · Configure · Control · SubHS · Tlk/Data · Remote
Page 43 of the Paradyne 3910 user manual — Top-Level Menu Status and Operational Messages
Page 43 · click to enlarge
Page 43

All menu tree branches are discussed later in Chapter 3 except for Configure, which is discussed in Chapter 4, and Security, which is discussed in Chapter 6. Functions that appear on the LCD vary depending upon the type of model installed, its operating mode, and software configuration.

Top-Level Menu Status and Operational Messages

Access to all menu tree branches from the DCP begins at the Top-Level menu, the head of the menu hierarchy. The LCD’s top line identifies the modem status, as listed in Table 3-3, while the bottom line displays the main menu tree branches as well as operational and security messages, as listed in Table 3-4 and Table 3-5.

(1 of 4) Top-Level Menu Status

Leased:MR* The modem is operating on leased lines and transmitting at the displayed data rate. p

Idle:MR* The modem is configured for dial network operation and is on-hook.

OnLine:MR* EC**

The modem is online, in Data mode, and operating at the displayed data rate. EC (error control) appears if error control is operational.

Ring Indicate The local modem is receiving an incoming ring.

Test:MR* The modem is in test mode operating at the displayed data rate.

Alarm*** Make Busy The modem is in a Make Busy condition.

Power On Fail The modem has failed its Power-On Self-test.

SelfHealth Fail A failure has occurred in the modem’s hardware components.

Call Setup Off Hook The modem is off-hook and waiting to dial a telephone number.

Dialing The originating modem is dialing a telephone number.

Remote Ring The remote modem is ringing.

Training**** The modem is training or retraining.

EC Negotiating The local and remote modems are negotiating the highest possible level of error control compatible between both modems. Once a level is selected, this LCD message disappears.

* MR. Modem Rate indicates the data rate the modem is using. One of the following values appears: 300, 1200, 2400, 4800, 7200, 9600, 12.0 (12,000), 14.4 (14,400), 16.8 (16,800), or 19.2 (19,200) bps.

** EC. Error Control indicates the modem is online and using V.42 or MNP error control. One of the following values appears after the modem rates listed above: MNP2, MNP3, MNP4, MNP5, V42, V42b, or NoEC. (NoEC indicates the modem is connected in Buffer mode rather than error control. If an EC value does not appear, then the modem is in Direct mode.)

*** The Alarm Status Messages only appear when the Normal Operation Status Messages appear; the LCD alternates between the two message sets.

**** The Training message may also appear in normal Trellis Multipoint (TMp) operation.

Show 4 more labels / short text on this page
DCP Operation · Table 3-3 · Status Message Indicates · Normal Operation
Page 44 of the Paradyne 3910 user manual — DCP Operation
Page 44 · click to enlarge
Page 44

(2 of 4) Top-Level Menu Status

Dial Backup or L d B k

Standby: MR* The modem is operating in Dial Standby mode. p Leased Backup DialBckUp:MR* The modem is operating in Dial Backup mode at the displayed data rate and is configured for Direct mode.

Backup:MR* EC**

The modem is operating in Dial Backup mode and is configured for error control and data compression on leased lines.

Standby:MR* EC**

The modem is operating in Dial Standby mode and is configured for error control and data compression on leased lines.

Call Failure Busy Signal The answering modem is busy.

As a result of failed call attempts, this number cannot be called at this time. Please try again later.

Dial Line in Use The modem is operating on dial networks when another call attempt is issued.

As a result of failed call attempts, this number cannot be called again.

Invalid Number The modem has dialed a telephone number not stored in a directory location.

The line is being used by the associated telephone.

The answering modem did not answer within the time limit specified by the No Answer Timeout configuration option. The network tones (if any) could not be interpreted by the modem.

* MR. Modem Rate indicates the data rate the modem is using. One of the following values appears: 300, 1200, 2400, 4800, 7200, 9600, 12.0 (12,000), 14.4 (14,400), 16.8 (16,800), or 19.2 (19,200) bps.

** EC. Error Control indicates the modem is online and using V.42 or MNP error control. One of the following values appears after the modem rates listed above: MNP2, MNP3, MNP4, MNP5, V42, V42b, or NoEC. (NoEC indicates the modem is connected in Buffer mode rather than error control. If an EC value does not appear, then the modem is in Direct mode.)

*** The Alarm Status Messages only appear when the Normal Operation Status Messages appear; the LCD alternates between the two message sets.

**** The Training message may also appear in normal Trellis Multipoint (TMp) operation.

The Delayed Number and Forbidden Number messages appear only in countries where the number of

repeat call attempts are restricted. The regulations vary in each country. If the number is delayed, the value of the delay (in minutes) can be displayed by entering Directory Status (see Call Setup Branch).

The Line Occupied message appears only in countries where the Offhook Detector is enabled. The

purpose of the Offhook Detector is to detect whether the telephone associated with the modem is off-hook. It is enabled on a per-country basis, and this setting cannot be changed by a command. The Offhook Detector is enabled in Austria, Germany, and Switzerland.

Show 6 more labels / short text on this page
Table 3-3 · Status Indicates Message · Delayed Number · Forbidden Number · Line Occupied · No Answer Tone
Page 45 of the Paradyne 3910 user manual — DCP Operation
Page 45 · click to enlarge
Page 45

(3 of 4) Top-Level Menu Status

Call Failure Cont.

No Dial–DTR The modem cannot dial because DTR is OFF.

No Dial–Test The modem cannot dial because it is running a Test.

No Dial Tone The modem has aborted the call because it cannot detect a dial tone.

The modem has detected No Quiet Answer (@) before the time-out setting of the No Answer Disconnect configuration option.

The answering modem did not answer within the time limit specified by the No Answer Timeout configuration option. A ringback signal was detected.

Trunk Busy The modem is receiving a fast (trunk) busy.

Wrong Call The call was answered, but not by a modem. No answer tone.

Call Disconnect ATH Disconnect The modem has disconnected due to an ATH command.

Bad Lines Disc The modem has disconnected because the lines do not support the modulation and/or data rate selected.

No Carrier Disc The modem disconnects due to the loss of carrier signal from the remote modem.

The modem has disconnected due to the loss of DTR from the DTE.

EC Disconnect The modem has disconnected due to failure to negotiate Error Control mode.

Inv Rate Disc When using V.32bis modulation, the remote modem does not support the data rate used by the local modem.

LnCurrnt Disc The modem has disconnected due to the loss of line current.

The modem has disconnected due to the detection of a long space.

NoData Disc The modem has disconnected due to a lack of transmitted and received data.

Disconnecting The modem has begun the disconnect sequence.

The modem has disconnected due to a V.32 Cleardown received from the remote modem.

Talk Mode The modem is in Talk mode.

A local download of firmware or a remote cloning of firmware has failed. The modem is currently in a Download Only mode in which only another download attempt is possible.

A local download of firmware or a remote cloning of firmware was successful.

A remote cloning of firmware has failed. This message appears on the local modem’s LCD.

Show 12 more labels / short text on this page
DCP Operation · Table 3-3 · Status Indicates Message · No Quiet Answer · Ringback Timeout · DTR Disconnect · LongSpace Disc · RmtCmnded Disc · Firmware Download Result · DownldOnly Mode · Frmware Upgrade · RemClone Failed
Page 46 of the Paradyne 3910 user manual — DCP Operation
Page 46 · click to enlarge
Page 46

(4 of 4) Top-Level Menu Status

Firmware Download Result Cont.

A remote cloning of firmware was successful. This message appears on the local modem’s LCD.

A broadcast cloning of firmware has completed. You must look under the Control branch for cloning results. This message appears on the local modem’s LCD.

Reset by AT command

The modem has performed a reset in response to an ATZ command.

Messages listed in Table 3-4 are common operational messages that occur during modem operation. These messages normally appear on the second line of the LCD.

Table 3-4 Common Operational Messages

Common Operational Message Indicates

Please Wait... A command to a local device takes more than two seconds to complete.

Command Sent... A command is sent to a remote modem.

No Rem Response or Remote Modem Fail

A remote modem does not respond to a command within 5 seconds.

Command Complete A command, issued to a local or remote modem, is completed.

Invalid Command The modem cannot complete a command.

Show 5 more labels / short text on this page
Table 3-3 · Status Indicates Message · Remote Clone OK · Bcast Clone Done · AT Command Reset
Page 47 of the Paradyne 3910 user manual — DCP Operation
Page 47 · click to enlarge
Page 47

Messages listed in Table 3-5 are dial access security messages.

Table 3-5 Dial Access Security Messages

Get VF PsWd The answering modem is waiting for the originating caller to transmit a VF password.

Get DTE PsWd The answering modem is waiting to receive a valid DTE password from the remote DTE.

VF PsWd Timeout The modem did not finish answering a call (disconnected) because the allowed time limit was exceeded before the modem received a VF password from the originating dialer.

Unknown DTEpswd The modem did not finish answering a call (disconnected) because the DTE passwords received from the remote DTE were invalid.

No Orig PsWd The modem did not attempt to establish a call as requested because the AT dial command did not contain an originate access password.

Unknown VF PsWd The modem did not finish answering a call (disconnected) because the modem received an invalid VF password.

DTEpswd Timeout The modem did not finish answering a call (disconnected) because the allowed time limit was exceeded before the modem received a DTE password from the remote DTE.

Inval Orig PsWd The modem did not attempt to establish the call as requested because the originate password in the AT dial command was not valid.

DTR Dial Blockd DTR dialing is not permitted when security is enabled. This message appears if DTR dialing is used and Answer Access or Originate Access security is enabled.

SecurityBlocked The access verification capabilities are not available and the modem does not pass data to the DTE under any circumstances. This message appears only when the modem is in base mode (a mode that occurs during a firmware download) and Answer Access Security is enabled.

The Top-Level menu’s main branches appear on the LCD in the order of Status, Configure, Control, Test, Call Setup, Talk/Data, Security, and Remote. These branches are discussed in this chapter except for the Configure branch which is reserved for Chapter 4, DCP Configuration, and the Security branch which is reserved for Chapter 6, Dial Access Security.

DCP Operation · Dial Access Security · Message Indicates

Page 48 of the Paradyne 3910 user manual — F1
Page 48 · click to enlarge
Page 48

Quick Configuration Display

The Quick Configuration display indicates the basic operational characteristics of the modem.

Leased:19.2 Status Configure

F1

F2 F3

To access the Quick Configuration display from the Top-Level display, press the key.

Leased:19.2 abbb cdd ee ffff

F1

F2 F3

The modem’s Quick Configuration information appears on the LCD’s bottom line.

a Displays the network position of the modem. The letter C indicates this is a control modem, and T indicates this is a tributary modem.

bbb Displays the network management address of the modem. The valid address field range is from 001 to 256.

c Displays the DTE mode. The letter A indicates the modem is in Asynchronous mode, and S indicates the modem is in Synchronous mode.

dd Displays the line mode. The letters LA indicate Leased Answer mode, LO indicate Leased Originate mode, and D indicates Dial mode.

ee Displays the modem DTE port that is currently being displayed by the EIA status indicators on the DCP.

P1 indicates Port 1. CC indicates Control Channel. DC indicates Diagnostic Channel.

ffff Displays the modem’s modulation scheme as shown below:

V32t indicates V.32 terbo modulation. V32b indicates V.32bis modulation. V32 indicates V.32 modulation. TMp indicates Trellis Multipoint modulation. V22b indicates V.22bis modulation. V27b indicates V.27bis modulation. V33 indicates V.33 modulation. V29 indicates V.29 modulation. V22 indicates V.22 modulation. V23 indicates V.23 modulation. V21 indicates V.21 modulation. 212A indicates Bell 212A modulation. 103J indicates Bell 103J modulation.

To exit the Quick Configuration function and return to the Top-Level menu, press the , , or key.

Page 49 of the Paradyne 3910 user manual — F1
Page 49 · click to enlarge
Page 49

Status Branch

The Status branch of the Top-Level menu allows you to view the current status of the leased-line or dial connection, the identity (for example, serial number and model number) of your equipment, and the DTE interface.

Configure PList Control Test SubHS Call_Setup Tlk/Data Security Remote

DeviceHS VF Identity DTE Options Record

Major Minor Status Dial Thresh Security Port1

Ser# Mod# FRev HPt# FPt#

LSD DTR DSR Tst TXD RXD RTS CTS

Line = Pri 4W APL Line = Pri 2W APL Line = Bkup 2W APL Line = Dial Backup Line = Dial ONLY Line = No Sync

1 These parameters appear for V.32 terbo, V.32bis, and V.32 modulations. 2 These parameters appear for Trellis Multipoint modulation.

To access Status from the Top-Level menu, select Status.

Leased:19.2 Status Configure

F1

F2 F3

Show 14 more labels / short text on this page
DCP Operation · “Status” · Status · Backup · SigQual1 · Display Clear · RcvLevel1,2 · Sig/Noise1,2 · NrEchLvl1 · FarEchLvl1 · FarEchDel1 · EchoFreqOff1 · NonLnearDist2 · Retrains2
Page 50 of the Paradyne 3910 user manual — F1
Page 50 · click to enlarge
Page 50

Device Health and Status (DeviceHS)

DeviceHS provides a ‘‘snapshot” of current modem alarms which are active at the time the DeviceHS function is selected.

To access DeviceHS from the Status branch, make the following selection:

Status> DeviceHS VF

F2 F3

F1

Select DeviceHS.

Device HS> Major Minor

F1

F2 F3

If alarms are present, press the appropriate function key to view the messages associated with these alarms (Table 3-6). If needed, press the key to scroll to additional alarm types. If no alarms are present, the word Normal appears on the LCD.

Page 51 of the Paradyne 3910 user manual — DCP Operation
Page 51 · click to enlarge
Page 51

(1 of 2) Health and Status Messages

Major Device Failure A device/self test has failed. The probable cause is a modem hardware problem or diagnostic memory failure.

Facility Fault A severe data transport problem is occurring due to poor line conditions. No signal or a very poor signal is being received.

Streaming DTE The modem is in an Antistreaming condition. The RTS input to the modem was held ON for a period exceeding the time selected by the RTS Antistream configuration option. (Refer to the DTE Interface section in Chapter 4 for a description of the RTS Antistream configuration option.)

Access Security A dial access security alarm is active. (Refer to the Security section of this table for dial access security conditions.)

Minor VF Threshold One or more of the analog parameter thresholds have been exceeded. The probable cause is poor line conditions or improper threshold settings. Thresholds may be set through the DCP or NMS commands.

DTE Alarm One or more of the DTE signals are in alarm mode. (Refer to the Port 1 section of this table for Port 1 DTE alarm conditions.)

Rate Fallback Due to poor line conditions, the modem’s transmit rate is below the configured rate. (Refer to the Leased Line and Dial Line sections in Chapter 4 for a description of configuration options affecting rate.)

Status Subtree Truncate Downstream health and status information has been truncated because it overflowed system limits. There is a large amount of health and status information in the subnetwork. This information can be recovered by sending device health and status commands to specific modems.

Test Mode The modem or an upstream device is running a disruptive test.

Disabled The modem’s DTE port has been disabled.

On Dial Backup The modem is operating in Dial Backup mode.

FW Downloading A firmware download is in progress.

On Lease Backup The modem is operating in Lease Backup mode. This status occurs only if the Dual Lease Line is enabled.

Primary Line Bad The modem is currently operating on the 2-wire backup facility, the Lease Lookback option is enabled, and the modem does not detect continuity on the primary 4-wire leased lines.

The modem is currently operating on the primary 4-wire leased facility with 2-wire leased lines selected as the backup facility, the Backup Line Check option is enabled, and the modem detects continuity on the 2-wire backup leased lines.

Data Blocked The modem’s primary data path is blocked.

PSTN Test Fail The modem failed either the Dial Tone Detection or the Ring Tone Detection portion of the Call Test command.

Show 4 more labels / short text on this page
DCP Operation · Table 3-6 · Type Message Indicates · Backup Line Good
Page 52 of the Paradyne 3910 user manual — DCP Operation
Page 52 · click to enlarge
Page 52

(2 of 2) Health and Status Messages

Dial Make Busy Mode The modem is in a Make Busy condition.

Service Line (Model 3911 only) The modem installed in a COMSPHERE 3000 Series Carrier has been switched to a service line.

Short Hold Time The modem’s dial hold time has been shortened.

Non-Answering The modem is in a non-answering mode.

Thresh* RSL High Threshd

The received signal level (RSL) has exceeded the upper threshold.

The RSL is less than the lower threshold.

SNR Threshold The signal-to-noise ratio has exceeded the threshold.

Non-linear Dist The non-linear distortion has exceeded the threshold.

Retrains The number of retrains has exceeded the threshold.

Signal Quality The signal quality is less than the threshold.

Far Echo Threshd The far end echo level has exceeded the threshold.

Near Echo Thresh The near end echo level has exceeded the threshold.

Security Database Reset The security database has been reset (passwords erased). y

Password Protect Security password protection has been enabled.

Mode Change There has been a change in security mode. (Refer to Chapter 6, Dial Access Security.)

Password Change A security password has been changed.

Database Change The security database containing passwords has been changed.

Port 1 Rx Data Alarm The DTE port’s RXD signal is in an alarm condition.

Tx Data Alarm The DTE port’s TXD signal is in an alarm condition.

DTR Alarm The DTE port’s DTR signal is in an alarm condition.

CTS Alarm The DTE port’s CTS signal is in an alarm condition.

RTS Alarm The DTE port’s RTS signal is in an alarm condition.

DSR Alarm The DTE port’s DSR signal is in an alarm condition.

LSD Alarm The DTE port’s LSD signal is in an alarm condition.

Auto Stream Dis The modem is in an Antistreaming condition. (Refer to the Streaming DTE message in the Major Alarm section of this table.)

Disabled The modem’s DTE port has been disabled.

*Not supported in every modulation.

To exit DeviceHS and remain in the Status Branch, press the key. To exit and return to the Top-Level menu, press the key.

Table 3-6 · Type Indicates Message · RSL Low Threshld

Page 53 of the Paradyne 3910 user manual — F1
Page 53 · click to enlarge
Page 53

VF

VF displays the condition of the leased or dial connection.

To access VF from the Status branch, make the following selection:

Status> DeviceHS VF

F1

F2 F3

Select VF.

Status:VF > SigQual=Excelent

F1

F2 F3

If the modem is receiving a signal, the signal quality appears on the LCD’s bottom line. Press the

key to scroll and view the receive signal level, signal-to-noise ratio, near end echo level, far end echo level, far end echo delay, and echo frequency offset. If the modem is not receiving a signal, the message No Signal appears on the LCD.

SigQual Signal Quality displays the condition of the VF line. Possible values are Excelent (Excellent), Good, Fair, Poor, or No Signal. These values appear for V.32 terbo, V.32bis, and V.32 modulations.

RcvLevel Receive Signal Level displays, in decibels referenced to one milliwatt (dBm), the actual strength of the incoming signal. This value appears for V.32 terbo, V.32bis, V.32, and Trellis Multipoint modulations.

Sig/Noise Signal-to-Noise Ratio displays, in decibels, the receive signal strength relative to noise on the line. This value appears for V.32 terbo, V.32bis, V.32, and Trellis Multipoint modulations.

NrEchLvl Near End Echo Level displays the signal level, in decibels referenced to one milliwatt (dBm), of that portion of the transmit signal which has been echoed back by the local line termination. This value appears for V.32 terbo, V.32bis, and V.32 modulations.

FarEchLvl Far End Echo Level displays the signal level, in decibels referenced to one milliwatt (dBm), of that portion of the transmit signal which has been echoed back by the remote line termination. This value appears for V.32 terbo, V.32bis, and V.32 modulations.

FarEchDel Far End Echo Delay displays the roundtrip delay in milliseconds of the far end echo. This value appears for V.32 terbo, V.32bis, and V.32 modulations.

EchoFreqOff Echo Frequency Offset displays the frequency offset of the far end echo. This value appears for V.32 terbo, V.32bis, and V.32 modulations.

DCP Operation

Page 54 of the Paradyne 3910 user manual — F1
Page 54 · click to enlarge
Page 54

NonLnearDist Non-Linear Distortion displays distortion which is usually associated with pulse-code modulation (PCM) compandor noise on the phone line. This value appears for Trellis Multipoint modulation.

Retrains Retrains displays the number of retrains over the last 15 minutes of operation. The total 15-minute accumulation is updated every minute. This value appears for Trellis Multipoint modulation.

To exit VF and remain in the Status Branch, press the key. To exit and return to the Top-Level menu, press the key.

Identity

Identity displays the modem’s serial number, model number, firmware revision level, hardware revision number and firmware part number. Retrieval of this information is useful if you are purchasing additional or replacement modems and/or making firmware upgrades.

To access Identity from the Status branch, make the following selection:

StatusVF Identity

F1

F2 F3

Press the key until Identity appears. Select Identity.

Status:Identity > Ser#=00000000

F1

F2 F3

The modem’s serial number appears on the LCD’s bottom line. Press the key to scroll and view the model number, firmware revision level, hardware part number, and firmware part number.

Ser # Serial number is an 8-digit number that identifies the modem.

Mod # Model number is an alphanumeric number that identifies the modem as either a Model 3910 or Model 3911 modem.

FRev Firmware revision level is an alphanumeric number that identifies the level of firmware loaded in the modem.

HPt # Hardware part number is an 11-digit number that identifies the circuit card in the modem.

FPt # Firmware part number is an 11-digit number that identifies to customer service personnel the firmware release number.

To exit the Identity function and remain in the Status branch, press the key. To exit and return to the Top-Level menu, press the key.

Page 55 of the Paradyne 3910 user manual — NOTE
Page 55 · click to enlarge
Page 55

DTE

DTE displays the state and/or activity of the following interface leads: LSD, DTR, DSR, Tst, TXD, RXD, RTS, and CTS. The interface leads status is updated every 5 seconds.

To access DTE from the Status branch, make the following selections:

StatusIdentity DTE

F2 F3

F1

Press the key until DTE appears. Select DTE.

LSD DTR DSR Tst> _ * _

F1

F2 F3

The activity and state of the modem’s DTE signal appear on the LCD’s bottom line. Press the key to scroll other signals into view.

The LCD’s bottom line displays a pair of symbols for each interface lead. The first symbol indicates the signal’s activity since entering the DTE status display. An * (asterisk) indicates at least one transition while a blank space indicates no transitions.

The second symbol indicates the state of the interface lead at the sampling time. A (solid block) indicates a Space or ON condition while an underscore ( _ ) indicates a Mark or OFF condition.

To exit this function and remain in the Status branch, press the key. To exit and return to the Top-Level menu, press the key.

Backup

The Status Backup function displays the configuration of the modem’s current operating line facility and the configuration and condition of the inactive line.

NOTE

The modem’s rear panel has two line interface jacks: LEASE and DIAL (see Figure 2-1 in Chapter 2). The jack labeled LEASE is the APL primary interface and accepts either 2-wire or 4-wire APL. The jack labeled DIAL is the backup interface and accepts either 2-wire APL (Dual Lease Line) or Dial lines.

DCP Operation

Page 56 of the Paradyne 3910 user manual — F1
Page 56 · click to enlarge
Page 56

To access Backup from the Status branch, make the following selection:

Press the key until Backup appears.

StatusDTE Backup

F1

F2 F3

Select Backup.

Status:Backup > Line=Pri 4w APL

F1

F2 F3

The configuration of the current operating line facility (either APL primary or backup) appears (Refer to Table 3-7).

Press the key to display the next screen.

Status:Backup < Bkup:2wAPL=Good

F1

F2 F3

This screen displays the configuration and condition of the inactive line facility (either APL primary or backup).

There are four condition codes, Good, Bad, , and ‘ ’ (blank).

Table 3-7 provides information about the Status Backup screens. The first column lists all possible configurations for the modem’s currently active line. The second column lists all possible configurations for the modem’s inactive lines. The third column provides information about the inactive line condition.

XXXX represents the condition code of the inactive line.

Page 57 of the Paradyne 3910 user manual — F1
Page 57 · click to enlarge
Page 57

Table 3-7 Backup Status Screens

Active Line 1st Screen Display Inactive Line 2nd Screen Display Possible Inactive/Backup Line Condition

Line=Pri 4w APL or Line=Pri 2w APL

Bckup:2wAPL=XXXX or Bckup : Dial =(blank)

Good indicates that line continuity is detected. Bad indicates that line continuity is not detected. indicates that the line condition is unknown (Backup Facility Check is making its first

determination of the line conditions since the last retrain). blank indicates that the Backup Line Check option is disabled.

Line=Bkup 2w APL or Line = Dial Backup

Pri 4w APL =XXXX or Pri 2w APL =XXXX

Good indicates the line condition is good. Bad indicates the line condition is bad. indicates the line condition is unknown (Lease Lookback has not had enough time to make an initial appraisal of the line conditions since the last retrain). blank indicates the Lease Lookback option is disabled.

Line=Dial Only No second screen display.

there is no backup. NOTEThe leased-line interface is disabled when the

factory default options are loaded from the Async Dial, Sync Dial, or UNIX Dial templates.

Line=No Sync No second screen display.

trained on either the primary or backup line facility.

To exit this function and remain in the Status branch, press the key. To exit and return to the Top-Level menu, press the key.

Options

The Options Status function displays all optional firmware features currently installed in the modem. If no firmware options are installed, None_Installed appears on the LCD.

To access Options from the Status branch, make the following sections:

StatusDTE Options

F1

F2 F3

Press the key until Options appears. Select Options.

DCP Operation

Page 58 of the Paradyne 3910 user manual — F1
Page 58 · click to enlarge
Page 58

Options:Status > V.29 V.33

F1

F2 F3

If optional features are installed in the modem, they appear on the LCD’s bottom line. If other features are installed, press the key to scroll other features into view.

To exit this function and remain in the Status branch, press the key. To exit and return to the Top-Level menu, press the key.

Record

Record is a troubleshooting tool used by the end user in conjunction with support personnel. This function allows the end user to retrieve and report any sequence faults to support personnel. A sequence fault is an irregular or unexpected event.

There are two selections under Record: Display and Clear. Display allows up to eight sequence fault messages that have been recorded by the modem to be displayed on the LCD. If no sequence faults have occurred, then Modem O.K. appears.

Clear is used to remove all sequence fault messages from nonvolatile memory and the LCD.

To access Record from the Status branch, make the following selections:

Status< Options Record

F1

F2 F3

Press the key until Record appears. Select Record.

Record Status Display Clear

F1

F2 F3

To display sequence faults, select Display.

Record Number 1 Modem O.K.

F1

F2 F3

Page 59 of the Paradyne 3910 user manual — Poll List Branch
Page 59 · click to enlarge
Page 59

The LCD displays the first sequence fault field. (Sequence fault fields range from 1 to 8 and are identified by a number in the upper right corner.) Press the key to view the remaining fields. The message Modem O.K. appears if no sequence faults have occurred.

To remove sequence fault records from both the LCD and nonvolatile memory, select Clear. The message Modem O.K. appears.

To exit this function and remain in the Status branch, press the key. To exit and return to the Top-Level menu, press the key.

Configure Branch

The Configure branch of the LCD allows you to change and save the modem’s configuration options. For configuration options and DCP configuration procedures, refer to Chapter 4, DCP Configuration.

Poll List Branch

The Poll List function is not available on Point-to-Point control modems or Multipoint Tributary modems..

The Poll List (Plist) branch of the Top-Level menu allows you to identify downstream modems in order to support health and status polling and download broadcasting. The maximum number of devices is 32 on the secondary channel and 64 on the diagnostic channel.

Status Configure Control Test SubHS Call_Setup Tlk/Data Security Remote

Display Clear Change Add Acquire

Show 5 more labels / short text on this page
DCP Operation · “Status” · PList · (Tributary only) · Active Delete Skip
Page 60 of the Paradyne 3910 user manual — F1
Page 60 · click to enlarge
Page 60

To access PList from the Top-Level menu, make the following selections:

Leased:19.2 PList Control

F1

F2 F3

Press the key until PList appears. Select PList.

Within a network link, a control modem can communicate with a tributary modem by using the tributary modem’s network management address for polling functions. Each tributary modem must have a different network management address. Refer to the Misc section in Chapter 4 for a description of the network management address (NetMngmtAddress) configuration option.

Over a diagnostic channel a tributary modem can communicate with control modems by using the control modem’s network management address for polling functions.

In the poll list, modems may be listed as either Active or Skip. Modems in the Active poll list are polled by the upstream modem. Modems in the Skip poll list are passed over during the polling process, but they are not deleted from the poll list.

Display

Display allows you to view the modem’s poll list.

To access Display from the PList branch, make the following selection:

Poll List> Display Clear

F1

F2 F3

Select Display.

NOTE

If there are no modems in the poll list when you select Display, the message Poll List Empty! appears on the second line of the LCD.

Poll List:Disp Nxt xxx yyyyyy

F1

F2 F3

Page 61 of the Paradyne 3910 user manual — F1
Page 61 · click to enlarge
Page 61

If there are modems in the poll list when you select Display,

xxx Displays the network management address of the modem in the poll list.

yyyyyy Displays either Active or Skip to indicate the poll list in which the network management address is included.

Select Nxt to scroll through the entries in the Active or Skip poll lists.

To exit this function and remain in the PList Display branch, press the key. To exit and return to the Top-Level menu, press the key.

Clear

The Clear function does not appear in Remote mode.

Clear deletes the modem’s poll list.

To access Clear from the PList branch, make the following selection:

Poll List> Display Clear

F1

F2 F3

Select Clear.

The message Command Complete appears on the second line of the LCD to indicate that the poll list has been cleared.

To exit this function and remain in the PList branch, press the key. To exit and return to the Top-Level menu, press the key.

Change

The Change function does not appear in Remote.

Change allows you to change the modem’s poll list.

To access Change from the PList branch, make the following selections:

Poll ListClear Change

F1

F2 F3

Press the key until Change appears. Select Change.

Change allows you to add modems to the Active poll list (Active), delete modems from both Active and Skip poll lists (Delete), and move modems from the Active to the Skip poll list.

DCP Operation

Page 62 of the Paradyne 3910 user manual — F1
Page 62 · click to enlarge
Page 62

Poll List:Chang > Active Delete

F1

F2 F3

To implement Change, select the appropriate function (Active, Delete, or Skip). (For Skip, you will need to press the key until Skip appears.)

Poll List:yyyyyy Ent xxx

F1

F2 F3

The function field (yyyyyy) displays the function you selected (Active, Delete, or Skip).

The address field (xxx) displays the network management address of the modem to be changed. The valid address field range is from 001 to 256.

To increment digits within the address field (xxx), use the and keys to position the cursor ( _ ) under the digit that will be incremented. Press the F2 () key to increment the digit.

Press Enter (Ent) to implement the function (yyyyyy) you selected (Active, Delete, or Skip). The message Command Complete appears on the second line of the LCD to indicate that the poll list change has occurred. If the message Poll List Check appears, you have attempted to delete an address that was not on the poll list, or you have attempted to add an address that was already on the poll list. If the message Poll List Error appears, you are in a point-to-point mode that does not support secondary channel (V.29). If the message Poll Lst too Big appears, you have entered a number greater than the maximum number of downstream devices. To return to the selected function (Active, Delete, or Skip), press the key. The address automatically increments upon returning to this function.

To exit this function (Active, Delete, or Skip) and remain in the PList Change branch, press the key. To exit and return to the Top-Level menu, press the key.

Add

The Add function does not appear in Remote mode or on control modems.

Add allows you to add the tributary modem to a control modem’s poll list. This function should be initiated from only one tributary modem at a time.

To access Add from the Plist branch, make the following selections:

Poll ListChange Add

F1

F2 F3

Press the key until Add appears. Select Add.

Page 63 of the Paradyne 3910 user manual — F1
Page 63 · click to enlarge
Page 63

Poll List:Add Command Complete

F1

F2 F3

The message Command Complete appears on the LCD to indicate that the tributary modem will be added to the control modem’s poll list.

To exit this function and remain in the PList branch, press the key. To exit and return to the Top-Level menu, press the key.

Acquire

The Acquire function does not appear in Remote mode.

Acquire allows you to acquire an active poll list consisting of all modems that are one tier downstream. A modem will add to its poll list all downstream devices that respond to a poll.

To access Acquire from the Plist branch, make the following selections:

Poll List< Add Acquire

F1

F2 F3

Press the key until Acquire appears. Select Acquire.

NOTE

If an error message (OtherTestActive or Unable To Acquir) appears on the second line of the LCD, move up one level in the menu tree to clear the message and return to the PList Acquire branch. The OtherTestActive message indicates that a test is running which blocks the Acquire function. The Unable To Acquir message indicates that the diagnostic network is in a busy state.

Poll List:Acquir Abort xxx yyy

F1

F2 F3

The address field (xxx) increments sequentially from 001 to 256 as polls are transmitted from the modem to the downstream modem(s). To be added to the modem’s poll list, the device must respond to a poll after receiving its address. The Acquire function can be canceled by selecting Abort.

DCP Operation

Page 64 of the Paradyne 3910 user manual — F1
Page 64 · click to enlarge
Page 64

The number field (yyy) indicates the total number of devices that responded to the modem’s polls. These devices have been acquired for the poll list.

Select Abort or allow the function to complete.

Poll List:Acquir Num Acquired yyy

F1

F2 F3

The number field (yyy) indicates the total number of devices acquired for the poll list.

To exit this function and remain in the PList branch, press the key. To exit and return to the Top-Level menu, press the key.

Control Branch

The Control branch of the Top-Level menu allows you to manage hardware and software functions, such as speaker volume, reset, busy out, and firmware download.

Status Configure PList Test SubHS Call_Setup Tlk/Data Security Remote

Speaker Reset Data_Stream Make_Busy

To access Control from the Top-Level menu, make the following selections:

Leased:19.2 Control Test

F1

F2 F3

Press the key until Control appears. Select Control.

Show 9 more labels / short text on this page
“Status” · Control · (3910 only) · (3911 only) · VF_Thresh_Update EIA_LEDs · Service_Line · Download_Code (DownLoadSoftware) · or RemoveMakeBusy · or DiscServiceLine
Page 65 of the Paradyne 3910 user manual — Reset
Page 65 · click to enlarge
Page 65

Speaker

Speaker allows you to make temporary adjustments to the modem’s speaker volume. Upon a reset, speaker volume returns to its configured setting. For more information on speaker settings, refer to the Misc section in Chapter 4.

To access Speaker from the Control branch, make the following selection:

Control> Speaker Reset

F1

F2 F3

Select Speaker.

Speaker Control > Off Low Med

F1

F2 F3

Press the key and appropriate function keys to choose the desired selection.

Off Turns the speaker off.

Low Adjusts the speaker to low volume.

Med Adjusts the speaker to medium volume.

High Adjusts the speaker to high volume.

The message Command Complete appears on the LCD.

To exit Speaker and remain in the Control branch, press the key. To exit and return to the Top-Level menu, press the key.

Reset

Reset causes the modem to stop operation and perform a complete program restart. The modem begins the power-up test sequence that ends with the Top-Level menu displayed on the LCD. Configuration options stored in an Active (Saved) configuration area are copied to the Active (Operating) configuration area.

DCP Operation · DCP selections are

Page 66 of the Paradyne 3910 user manual — F1
Page 66 · click to enlarge
Page 66

To access Reset from the Control branch, make the following selection:

Control> Speaker Reset

F1

F2 F3

Select Reset.

The message Reset appears momentarily before the modem performs the power-up diagnostic test sequence.

Data Stream

The Data Stream function is not available in Async mode.

Use Data Stream to enable or disable the modem’s data transmitter function.

To access Data Stream from the Control branch, make the following selections:

ControlData_Stream

F1

F2 F3

Press the key until Data_Stream appears. Select Data_Stream.

The Data Stream action which is available (Disable or Enable) appears on the second line of the LCD beside the word Port1. If the modem’s data transmitter is enabled, the word Disable appears to indicated that you may disable the data transmitter by selecting this action.

Data Stream Port1 Disable

F1

F2 F3

If you want to disable the modem’s data stream, press the F2 key. When the message Command Complete appears, press the key to clear the message.

Data Stream Port1 Enable

F1

F2 F3

Press the F2 key again to enable the modem’s data stream.

Page 67 of the Paradyne 3910 user manual — NOTE
Page 67 · click to enlarge
Page 67

To exit this function and remain in the Control branch, press the key. To exit and return to the Top-Level menu, press the key.

EIA LEDs

Use the EIA LEDs function to change the port that controls the front panel LEDs. This function allows the front panel EIA LEDs to display the activity of a selected digital interface.

To access EIA LEDs from the Control branch, make the following selections:

ControlEIA_LEDs

F1

F2 F3

Press the key until EIA_LEDs appears. Select EIA_LEDs.

EIA_LEDxxxxx Port1 CC

F1

F2 F3

Press the F1 key until the appropriate digital interface appears.

The xxxxx field displays the currently selected interface. The valid interfaces are Port1, and depending on the configuration option, either CC (NMS Control Channel), or DC (Diagnostic Channel). Refer to the section Miscellaneous Configuration Options, Diag Connection in Chapter 4.

Select the appropriate interface by pressing the corresponding function key.

EIA_LEDxxxxx Command Complete

F1

F2 F3

After selecting the desired interface, the message Command Complete appears on the bottom line of the LCD and the selected interface appears in the xxxxx field.

To exit this function and remain in the Control branch, press the key. To exit and return to the Top-Level menu, press the key.

NOTE

The Port1 interface is the only display allowed on the 3911 modem, therefore, the entire EIA LEDs branch is masked.

DCP Operation

Page 68 of the Paradyne 3910 user manual — F1
Page 68 · click to enlarge
Page 68

Make Busy/Remove Make Busy

The Make Busy function forces the modem off-hook so it cannot answer a call. This is often used with PBX systems to permit the busy out of a PBX port for rotary or hunt groups.

WARNING

To prevent violations of FCC and DOC regulations, this function must only be used behind a user’s PBX.

To access Make Busy from the Control branch, make the following selections:

ControlMake_Busy

F1

F2 F3

Press the key until Make_Busy appears. Select Make Busy.

Make Busy Command Complete

F1

F2 F3

The modem is now in a forced busy condition. Command Complete appears on the LCD.

To remove the modem from Make Busy mode, press the key once and the key until RemoveMakeBusy appears.

ControlRemoveMakeBusy

F1

F2 F3

Press any function key to select RemoveMakeBusy. The message Command Complete appears on the LCD.

Page 69 of the Paradyne 3910 user manual — Download Software
Page 69 · click to enlarge
Page 69

Service Line/Disconnect Service Line

The Service Line function allows you to switch a specific Model 3911 installed in a COMSPHERE 3000 Series Carrier from normal leased or dial operation to service-line operation. This switch only places the modem on the service line. For a connection to be established, you must still use the normal dialing methods as described earlier in this chapter in the Call Setup Branch section.

A service line is an extra dial line connected to a COMSPHERE 3000 Series Carrier. This line is normally shared by up to eight Model 3911 modems installed in either Slots 1–8 or Slots 9–16.

However, by daisy chaining the service-line connector of one Network Interface Module (NIM) to the service line of another NIM installed in the same carrier, you can permit all 16 modems to share one service line. The service line can also be extended to other carriers in a cabinet. For more information regarding daisy chaining of modems to the service line, refer to the COMSPHERE 3000 Series Carrier, Installation Manual.

A service line is ideal for a dial backup of Model 3911 modems operating on leased lines. Remember that a service line can back up only one failed leased line at a time.

To enable Service Line from the Control branch, make the following selections:

ControlService_Line

F1

F2 F3

Press the key until Service_Line appears. Select Service_Line to switch the modem from its normal dial line to the service line. Now, when the modem places a call, instead of using the dial line, the call is placed on the service line.

To disconnect the modem from the service line and resume normal operation, press the key once and the key until DiscServiceLine appears.

Select DiscServiceLine. The call and service line disconnect and the message Command Complete appears on the LCD.

Download Software

The Download Software function sets parameters within the modem when transferring firmware to one or more modems or when receiving firmware upgrades from a locally attached PC-based controller. The latter is only performed by customer service personnel.

There are two selections under Download Software: Clone Remote and To Local via DTE. Clone Remote is used to transfer an exact copy of the firmware currently stored in a 391x Series modem to either one or more remote 391x Series modems or one or more DC-attached 391x Series modems. Remote modems must be connected to the local modem via a leased-line network or an established dial-line network. If these prerequisites do not exist, Clone Remote will not appear on the LCD.

The second selection appearing on the LCD is To Local via DTE. This function permits firmware upgrades to be transferred to a 391x Series modem. This type of download requires a locally attached PC controller to be connected to the modem’s DTE port as well as special download software. Any downloads using this selection are intended to be performed by customer service personnel only.

DCP Operation

Page 70 of the Paradyne 3910 user manual — F1
Page 70 · click to enlarge
Page 70

NOTE

Clone Remote operations are not supported unless both local and remote modems are 391x Series modems. (The 3800 or 392x Series modems cannot be used in cloning operations with 391x Series modems.)

To access DwnLoadSoftware from the Control branch, make the following selections:

ControlDownload_Code

F1

F2 F3

Press the key until Download_Code appears. Press any function key to select Download_Code. The DwnLoadSoftware screen appears.

F1

F2 F3

Press any function key to select Clone_Remote.

The next screen to appear is determined by the modem’s configuration. Refer to the appropriate section (Point-to-Point, Broadcast, or Multipoint).

Clone Remote in Point-to-Point Configurations

Before using Clone Remote in point-to-point configurations, perform the following:

  • Make sure the 391x Series modems have an established leased-line connection using either V.33, V.32 terbo, V .32bis, V .32, or V.29 modulation (refer to the Leased Line section in Chapter 4) or a dial network connection using either V.32 terbo, V.32bis or V.32 modulation (refer to the Dial Line section in Chapter 4).
  • Make sure the remote modem’s Access From Remote configuration option is enabled (refer to the Misc section in Chapter 4).
  • Make sure the password (Remote Access Password configuration option) is the same in both the local and remote modems. (For an example of how to change the password, refer to the Editing and Saving a Configuration Option section in Chapter 4.)

After completing these checks, proceed to the section titled Implementing a Clone Remote Operation, which follows the descriptions of multipoint cloning operations.

Selecting Clone Remote · DwnLoadSoftware > Clone_Remote

Page 71 of the Paradyne 3910 user manual — F1
Page 71 · click to enlarge
Page 71

Clone Remote in Broadcast Configurations

A tributary modem configured for extended diagnostics (Diagnostic Connection configuration option set to Modem(DC)) can perform two types of Remote Clone operations. It can clone the upstream, VF connected, control modem (SC_Clone) or it can clone all the 391x modems attached to its downstream Diagnostic Channel (DC_Broadcast).

Choose DLL Type > SC_Clone

F1

F2 F3

From the Choose DLL Type screen, press the F1 key to select SC_Clone to request the transfer of an exact copy of the tributary modem’s firmware to the VF connected control modem.

Proceed to the section titled Implementing a Clone Remote Operation, which follows the descriptions of multipoint cloning operations.

Cloning DC Broadcast Remote

Before using Clone Remote in DC Broadcast configurations, make sure the tributary modem’s active poll list contains all the network management addresses for the control modems that receive the download (refer to the Poll List section in this chapter), and ensure that the control modems are responding properly to polls (refer to the Sub-Network Health and Status Branch sections in this chapter).

Choose DLL Type > DC_Broadcast

F1

F2 F3

From the Choose DLL Type screen, press the key until DC_Broadcast appears. Press F1 or F2 to transfer an exact copy of the tributary modem’s firmware to the DC-connected control modem(s) using the Active Poll list.

Proceed to the section titled Implementing a Clone Remote Operation, which follows the descriptions of multipoint cloning operations.

DCP Operation

Page 72 of the Paradyne 3910 user manual — NOTE
Page 72 · click to enlarge
Page 72

Viewing DC Broadcast Clone Results

Choose DLL Type > DC_CloneResults

F1

F2 F3

From the Choose DLL Type screen, press the key until DC_CloneResults appears to view the results of the last DC_Broadcast clone operation. If the message Trib List Empty appears, this indicates that a multiple download was never initiated.

DC Clone Results Nxt xxx Pass

F1

F2 F3

The address field (xxx) displays the network management address of one of the remote modems. Pressing the F1 key allows you to select various remote modems to determine the download result for those modems (Pass or Fail).

Clone Remote in Multipoint Configurations

A Trellis Multipoint (TMp) control modem can be used to download firmware to just one tributary modem (Single) or to all of its tributary modems (Multiple).

NOTE

A Trellis Multipoint (TMp) tributary modem cannot download firmware to its control modem. To download firmware to a TMp control modem use a point-to-point dial connection, an NMS, or a PC controller.

Before using Clone Remote in multipoint configurations (Single or Multiple), perform the following:

  • Make sure the 391x Series modems have an established leased-line connection using the Trellis Multipoint (TMp) modulation (refer to the Leased Line section in Chapter 4).
  • Make sure the remote modem’s Access From Remote configuration option is enabled (refer to the Misc section in Chapter 4).
  • For Single download configurations, know the remote access password and the network management address of the remote tributary modem that will receive the download. Refer to the Misc section in Chapter 4 for a description of the remote access password (RemAccssPasswrd) configuration option and the network management address (NetMngmtAddress) configuration option.
Page 73 of the Paradyne 3910 user manual — F1
Page 73 · click to enlarge
Page 73
  • For Multiple download configurations, ensure that the control modem’ s active poll list contains all the network management addresses for the remote tributary modems that will receive the download (refer to the Poll List section in this chapter), and ensure that the tributaries are responding properly to polls (refer to the Sub-Network Health and Status Branch section in this chapter).

Cloning a Single TMp Remote

Choose DLL Type > Single Multiple

F1

F2 F3

Press the F1 key to select Single Clone Remote.

Choose AddressEnt xxx

F1

F2 F3

The address field (xxx) displays the network management address of the modem that will receive the download. The valid address field range is from 001 to 256.

To increment digits within the address field (xxx), use the and keys to position the cursor ( _ ) under the digit that will be incremented. Press the F2 () key to increment the digit.

Press Enter (Ent) to select the modem that will receive the download.

Choose PasswordEnt yyyyyyyy

F1

F2 F3

The password field (yyyyyyyy) displays the remote access password for the modem that will receive the download.

To increment digits within the password field (yyyyyyyy), use the and keys to position the cursor ( _ ) under the digit that will be incremented. Press the F2 ( ) key to increment the digit.

Press Enter (Ent) to select the modem that will receive the download.

After completing these actions, proceed to the section titled Implementing a Clone Remote Operation.

DCP Operation

Page 74 of the Paradyne 3910 user manual — WARNING
Page 74 · click to enlarge
Page 74

Cloning a Multiple TMp Remote

Choose DLL Type > Single Multiple

F1

F2 F3

Press the F3 key to select Multiple Clone Remote.

After completing this action, proceed to the next section, Implementing a Clone Remote Operation.

Viewing Multiple TMp Clone Results

Choose DLL Type > MPtCloneResults

F1

F2 F3

From the Choose DLL Type screen, press the key until the MPtCloneResults screen appears to view the results of the last multiple TMp clone operation. If the message Trib List Empty appears, this indicates that a multiple download was never initiated.

MPtCloneResults Nxt xxx Pass

F1

F2 F3

The address field (xxx) displays the network management address of one of the remote modems. Pressing the F1 key allows you to select various remote modems to determine the download result for those modems (Pass or Fail).

Implementing a Clone Remote Operation

WARNING

The modem begins a transfer of its own program to the remote modem. This process takes the communication link out-of-service for several minutes depending on the data rate of the link. If the Clone Remote process is started and then interrupted, the remote modem is left in a partially programmed state in which its functional capabilities are limited to those required to initiate and complete another download attempt.

Page 75 of the Paradyne 3910 user manual — F1
Page 75 · click to enlarge
Page 75

F1

F2 F3

At this point, if you do not want to continue this process, abort the transfer by selecting any function key. This returns the modem to the DwnLoadSoftware menu. However, to continue with the transfer, press the key to display the Reprogram_Remote selection.

F2 F3

F1

Press any function key to begin the transfer.

RemClone Status Establish Remote

F1

F2 F3

The local modem’s LCD displays Establish Remote, indicating the modem is attempting to establish a Remote Cloning Download session with the remote modem.

If unsuccessful, the modem remains in the Download Transfer mode. The LCD’s top line displays RemClone Failed and the bottom line displays one of the following messages:

Incompat Modulat The modems are connected, but are using a modulation scheme other than V.33, V.32 terbo, V.32bis, V.32, V.29, or TMp.

No Response The remote modem is not a 3900 Series modem or the connection between the two modems is poor.

Access Disabled The remote modem’s Access from Remote configuration is disabled.

Password Invalid The local and remote modems’ passwords do not match. Correct the problem and attempt another download from the local modem. If this fails, contact your service representative.

No Circuit There is no connection between the local and remote modem.

After successful establishment of a Remote Cloning Download session, the following screens appear.

F1

F2 F3

DCP Operation · RemClone Status Initializing

Page 76 of the Paradyne 3910 user manual — F1
Page 76 · click to enlarge
Page 76

RemClone Status Bank1:xxxx/yyyy

F1

F2 F3

As data banks are transferred, the local and remote LCD’s bottom line displays the status of the download process, and the number of records sent versus the total number of records for that bank.

For Single download applications, if the download is successful, the local modem displays Remote Clone OK and the remote modem displays Frmware Upgrade. If the download took place over the dial network, the modems disconnect when the download is complete.

If the Single download is unsuccessful, RemClone Failed appears on the LCD’s top line. Attempt another download from the local modem. If this fails, contact your service representative.

VF Thresholds Update

The VF Thresholds Update function allows you to set the thresholds that determine the Health and Status alarm conditions for the VF parameters. The following thresholds may be edited: RSL High, RSL Low, Sig/Noise, NonLinear, Retrains/15min, Signal Quality, Near Echo, and Far Echo. (For Health and Status alarm conditions, refer to Table 3-6 in the Device Health and Status (DeviceHS) section of this chapter.)

To access VF Thresh Update from the Control branch, make the following selections:

Control< VF_Thresh_Update

F1

F2 F3

Press the key until VF_Thresh_Update appears. Press any function key to select VF_Thresh_Update.

VF Thresholds Edit Save Reset

F1

F2 F3

Select Edit.

In the following example, the RSL High threshold is changed from 09 (–dBm) to 10. This example demonstrates VF threshold editing and saving. With the exception of Signal Quality, all VF thresholds may be modified in this manner. Signal Quality uses a menu selection with possible values of Excelent (Excellent), Good, Fair, Poor, or No Signal. Editing and saving a VF threshold is similar to editing and saving a configuration option. (For another example of editing and saving, refer to the Editing and Saving a Configuration Option section in Chapter 4.)

Page 77 of the Paradyne 3910 user manual — F1
Page 77 · click to enlarge
Page 77

RSL High (- dBm) Nxt 09

F1

F2 F3

In the example shown above, 09 is the upper (High) RSL threshold (in -dBm). To change the 09 to 10, make the following selections:

RSL High (- dBm) Nxt 19

F1

F2 F3

Select the F2 ( ) key to increment the number above the cursor ( 0 ) to 1.

NOTE

RSL High (- dBm) Nxt 19

F1

F2 F3

Press the key to move the cursor to the next position ( 9 ).

Select the F2 ( ) key to change the number above the cursor ( 9 ) to 0.

RSL High (- dBm) Nxt 10

F1

F2 F3

NOTE

If you want to modify additional VF thresholds, select Nxt.

Show 4 more labels / short text on this page
DCP Operation · r · r · r
Page 78 of the Paradyne 3910 user manual — F1
Page 78 · click to enlarge
Page 78

To save the edited threshold(s):

RSL High (- dBm) Nxt 10

F1

F2 F3

Press the key to scroll up to the Edit/Save screen.

VF Thresholds Edit Save Reset

F1

F2 F3

Select Save.

If the edited VF thresholds are valid, the Save command stores them into nonvolatile memory. When the Save completes, the message Save Completed appears.

Save VF Thresh Thd Out of Range

F1

F2 F3

If the edited VF threshold is invalid (out of range), the error message Thd Out of Range appears. This indicates the Save procedure was unsuccessful. Return to the Edit screen and correct the invalid threshold range.

To correct the invalid VF threshold, press the key to return to the VF Threshold Edit/Save/Reset screen.

VF Thresholds Edit Save Reset

F1

F2 F3

Select Reset to restore the original default values into memory.

Repeat the Edit and Save procedure until the VF threshold(s) is valid and the Save completes successfully (Save Completed).

To exit this function and remain in the Control branch, press the key. To exit and return to the Top-Level menu, press the key.

Page 79 of the Paradyne 3910 user manual — DCP Operation
Page 79 · click to enlarge
Page 79

Table 3-8 Valid Ranges for VF Thresholds

VF Thresholds Valid Ranges Default Values

Receive Signal Level High 0 dBm to –15 dBm Above –9 dBm

Receive Signal Level Low –16 dBm to –50 dBm Below –23 dBm

Signal to Noise Ratio 5 dB to 40 dB Below 23 dB

Non-Linear Distortion 15 dB to 50 dB Below 30 dB

Retrains 1 to 256 trains 15 trains per 15 minutes

Signal Quality Excellent (lowest) Good Fair Poor No Signal (highest)

Near Echo 0—38 dBm Above –20 dBm

Far Echo 0—38 dBm Above –20 dBm

DCP Operation · Good

Page 80 of the Paradyne 3910 user manual — Abort
Page 80 · click to enlarge
Page 80

Test Branch

The Test branch of the Top-Level menu allows you to initiate various modem tests. Use these tests if you are having data communication problems, such as periodic character loss, random errors, or constant format errors. By the process of elimination, you can usually isolate the fault in your system.

There are six selections under Test: Abort, Self (Self-Test), Loc Analog Loop (Local Analog Loopback), Rem Digital Loop (Remote Digital Loopback), Loc Digital Loop (Local Digital Loopback), and Pattern. The only tests that can operate concurrently on a single modem are Pattern with a Local Analog Loopback and Pattern with a Remote Digital Loopback. If any test is operating, besides the two combinations just mentioned, it must be canceled before starting another test.

The Test branch only initiates and cancels tests. If any parameters need to be set, refer to the Test section discussed in Chapter 4, DCP Configuration.

Status Configure PList Control SubHS Call_Setup Tlk/Data Security Remote

Abort Self Loc_Analog_Loop Rem_Digital_Loop Loc_Digital_Loop Pattern

To access the Test branch from the Top-Level menu, make the following selections:

Leased:19.2 Control Test

F1

F2 F3

Press the key until Test appears. Select Test.

Abort

Abort ends any test that is in progress and brings the modem back to the normal mode of operation. Confirmation is provided by the Command Complete message.

“Status” · Test

Page 81 of the Paradyne 3910 user manual — F1
Page 81 · click to enlarge
Page 81

To access Abort from the Test branch, make the following selection:

Test> Abort Self

F1

F2 F3

Select Abort.

Test:Abort Command Complete

F1

F2 F3

The modem stops all tests currently in progress and displays the Command Complete status message on the LCD.

To exit this function and remain in the Test branch, press the key. To exit and return to the Top-Level menu, press the key.

Self

Self performs an internal self-test of the modem, which takes less than a minute to complete. The modem must be offline; otherwise, Invalid Command appears.

WARNING

When this test is run in Remote mode, it will cause the Remote mode session to be lost. The Remote mode session can be reestablished after the self-test is complete (usually one or two minutes). If the remote self-test fails, there will be a Device Failure alarm message when the remote modem’s Device Health and Status (DeviceHS) branch is accessed.

To access Self from the Test branch, make the following selection:

Test> Abort Self

F1

F2 F3

Select Self. (All LCD cells and DCP status indicators light.)

DCP Operation

Page 82 of the Paradyne 3910 user manual — F1
Page 82 · click to enlarge
Page 82

NOTE

For tributary modems only, the test is delayed 30 seconds to allow any outstanding network management messages to propagate upstream before the VF channel is interrupted by the test.

If the modem passes the self-test, Pass appears on the LCD. If it fails, Failed appears. If the modem fails, contact your service representative. If Invalid Command appears on the LCD, the modem is operating on dial lines or another test is in progress. If another test is in progress, select Abort to clear the current test and try again. If the modem is operating on dial lines, disconnect to clear the dial lines, and then choose Self. If the modem receives a ring signal during this test, the test is canceled and the RI Abort message appears.

To exit this function and remain in the Test branch, press the key. To exit and return to the Top-Level menu, press the key.

Loc Analog Loop

Loc Analog Loop performs a local analog loopback (CCITT V.54 Loop 3), Figure 3-4, that verifies modem operation as well as the connection between the DTE and modem. The modem must be offline and in Synchronous or Asynchronous Direct mode to perform this test, otherwise Invalid Command appears.

Paradyne 3910 — Loc Analog Loop diagram (page 82)
Fig. 6 · Loc Analog Loop

Figure 3-4. Local Analog Loopback

To access Loc Analog Loop from the Test branch, make the following selections:

TestLoc_Analog_Loop

F1

F2 F3

Press the key until Loc_Analog_Loop appears. Press any function key to start this test.

Page 83 of the Paradyne 3910 user manual — Rem Digital Loop
Page 83 · click to enlarge
Page 83

Test:Local Loop Started

F1

F2 F3

NOTE

For tributary modems only, the test is delayed 30 seconds to allow any outstanding network management messages to propagate upstream before the VF channel is interrupted by the test.

The message Started appears on the LCD, and the Test LED lights for the duration of the test. If Invalid Command appears on the LCD, another test is in progress. Select Abort to clear the current test and try again. If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the test. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to the Test section in Chapter 4. A Ring Indicate during this test can cause errors.

To exit this function and remain in the Test branch, press the key. To exit and return to the Top-Level menu, press the key.

Rem Digital Loop

This test is not available when using TMp modulation or Remote mode.

Rem Digital Loop performs a remote digital loopback (CCITT V.54 Loop 2), Figure 3-5. This test can verify the integrity of the local modem, the communication link, and the remote modem. Any data or pattern entered at the local DTE is sent to and returned from the remote modem. For this test to operate properly, the modems must be operating at the same rate and in Synchronous or Asynchronous Direct mode.

Paradyne 3910 — Rem Digital Loop diagram (page 83)
Fig. 7 · Rem Digital Loop

Figure 3-5. Remote Digital Loopback

DCP Operation

Page 84 of the Paradyne 3910 user manual — Loc Digital Loop
Page 84 · click to enlarge
Page 84

To access Rem Digital Loop from the Test branch, make the following selections:

TestRem_Digital_Loop

F1

F2 F3

Press the key until Rem_Digital_Loop appears. Press any function key to start this test.

Test:Remote Loop Started

F1

F2 F3

The message Started appears on the LCD, and the Test LED lights for the duration of the test. If Invalid Command appears on the LCD, another test is in progress. Select Abort to clear the current test and try again. If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the test. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to the Test section in Chapter 4.

To exit this function and remain in the Test branch, press the key. To exit and return to the Top-Level menu, press the key.

Loc Digital Loop

Loc Digital Loop is issued by a local modem and forces it to loopback any data received from the remote modem (Figure 3-6). (This test operates the same as a CCITT V.54 Loop 2 except it is issued at your modem.) This is useful if a remote modem is incapable of initiating a remote digital loopback from its location. For this test to operate properly, the modems must be operating at the same rate and in Synchronous or Asynchronous Direct mode.

Paradyne 3910 — Loc Digital Loop diagram (page 84)
Fig. 8 · Loc Digital Loop

Figure 3-6. Local Digital Loopback

Page 85 of the Paradyne 3910 user manual — Pattern
Page 85 · click to enlarge
Page 85

To access Loc Digital Loop from the Test branch, make the following selections:

TestLoc_Digital_Loop

F1

F2 F3

Press the key until Loc_Digital_Loop appears. Press any function key to start this test.

Test:Digitl Loop Started

F1

F2 F3

The message Started appears on the LCD and the Test LED lights. If Invalid Command appears on the LCD, another test is in progress. Select Abort to clear the current test and try again. If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the display. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to the Test section in Chapter 4.

To exit this function and remain in the Test branch, press the key. To exit and return to the Top-Level menu, press the key.

Pattern

Pattern can transmit and receive a 511 bit error rate test pattern. It can also be used with a currently running local analog loopback or a remote digital loopback to simulate data passing through the modem. You will need to start the local analog or remote digital loopback test before you start the pattern test. For this test to operate properly, the modems must be online and in Synchronous or Asynchronous Direct mode (Figures 3-7 through 3-9).

Paradyne 3910 — Pattern diagram (page 85)
Fig. 9 · Pattern

Figure 3-7. Pattern Test and Local Analog Loopback Test

DCP Operation

Page 86 of the Paradyne 3910 user manual — F1
Page 86 · click to enlarge
Page 86
Paradyne 3910 — DCP Operation diagram (page 86)
Fig. 10 · DCP Operation

Figure 3-8. Pattern Test and Digital Loopback Test

Paradyne 3910 — DCP Operation diagram (page 86)
Fig. 11 · DCP Operation

Figure 3-9. End-to-End Pattern Test

To access Pattern from the Test branch, make the following selections:

Test< Pattern

F1

F2 F3

Press the key until Pattern appears. Select Pattern to start this test.

Test:Pattern > BlksErrd=xxxxxxx

F1

F2 F3

Page 87 of the Paradyne 3910 user manual — NOTE
Page 87 · click to enlarge
Page 87

BlksErrd=xxxxxxx displays the number of blocks of data found in error (block size is 1000 bits per block). BlksRcvd=xxxxxxx displays the total number of blocks of data received. The message NoSync appears as a value for BlksErrd while the modem’s receiver is synchronizing. The message OvrFlw appears as the value for BlksErrd if the counter overflows.

Press the key to display BlksRcvd=xxxxxxx, number of blocks of data received.

The Pattern test can be exited and reentered without restarting the test. The BlksErrd and BlksRcvd continue counting.

If the Test Timeout configuration option is enabled, Test Timeout appears at the conclusion of the test. If it is disabled, the test operates until aborted. For more information on the Test Timeout configuration option, refer to the Test section in Chapter 4.

To exit this function and remain in the Test branch, press the key. To exit and return to the Top-Level menu, press the key.

Sub-Network Health and Status Branch

The Sub-Network Health and Status (SubHS) function is not available on multipoint tributary modems or with certain modulations (V.29, V.33, V.22bis, and V.27bis).

The SubHS branch of the Top-Level menu allows you to display alarm conditions in downstream modems.

Status Configure Plist Control Test Call_Setup Tlk/Data Security Remote

To access the SubHS branch from the Top-Level menu, make the following selections:

Leased:19.2 Test SubHS

F1

F2 F3

Press the key until SubHS appears. Select SubHS.

NOTE

If there are no modems in the multipoint poll list, the message Poll List Empty! appears on the second line of the LCD.

DCP Operation · “Status” · SubHS

Page 88 of the Paradyne 3910 user manual — Call Setup Branch
Page 88 · click to enlarge
Page 88

Sub-network HS Nxt xxx yyyyyy

F1

F2 F3

When you select SubHS,

xxx Displays the network management address of the downstream modem selected.

yyyyyy Displays the status of the downstream modem. This message is updated every several seconds to display the latest status. MAJOR, MINOR, and STATUS display Health and Status alarm conditions; refer to Table 3-6 in the Device Health and Status (DeviceHS) section of this chapter for additional information. UNKNWN appears when the modem does not recognize the downstream health and status information or device communication is not established. Normal appears if no alarms are present. NO RSP appears when the downstream modem does not respond to the poll.

Select Nxt to scroll through the entries in the poll lists.

To exit this function and return to the Top-Level menu, press the key.

Call Setup Branch

The Call Setup function is not available in TMp Control mode.

For dial backup applications, the Call Setup branch of the Top-Level menu allows you to dial, disconnect, and answer telephone calls. For leased backup applications, the Call Setup branch allows you to switch between the primary leased line and the backup leased line.

In leased backup operation, a 2-wire leased line is used as the backup facility instead of the normal 2-wire dial line. Plug the leased line into the jack labeled DIAL on the rear panel of the modem and enable the Dual_Leased_Ln configuration option. (Refer to the Leased Line section in Chapter 4 for configuration options.) Except for dialing, ring indication, and call progression functions, you control the backup function as if it were a normal dial backup.

Page 89 of the Paradyne 3910 user manual — F1
Page 89 · click to enlarge
Page 89

Status Configure PList Control Test SubHS Tlk/Data Security Remote

Dial Disconnect Answer Dial_Standby

(Does not appear in North America)

Directory Locations 1 - 24

To access the Call Setup branch from the Top-Level menu, make the following selections:

Leased:19.2 Call_Setup

F1

F2 F3

Press the key until Call_Setup appears. Select Call_Setup.

Dial

For dial backup applications, Dial allows you to dial any telephone number stored in directory locations 1–24. Any telephone number dialed using the DCP must already exist in a directory location. Refer to Change Directory for information on storing telephone numbers in directory locations.

For leased backup applications, Dial allows you to switch to the backup leased line. Any directory location may be used. The remote modem cannot automatically answer the simulated call. Use the Answer function of the remote modem in conjunction with the Dial function to manually switch to the backup leased line.

To access Dial from the Call Setup branch, make the following selection:

Call Setup> Dial Disconnect

F1

F2 F3

Select Dial to display the first directory telephone number.

Show 8 more labels / short text on this page
DCP Operation · “Status” · (Dial Backup · Call_Setup · only) · Change_Directory · Directory_Status · or Return_to_Dial
Page 90 of the Paradyne 3910 user manual — F1
Page 90 · click to enlarge
Page 90
DialDirectoryNxt 01:5551234

F1

F2 F3

To view other directory locations, select Nxt.

DialDirectoryNxt 02:5461879

F1

F2 F3

Once the directory location you want appears on the LCD, press the F2 or F3 key to dial the number.

DialDirectory:01 Off Hook

F1

F2 F3

The Call Setup status Off Hook appears during the connection process. If the connection is successful, one of the Normal Operation status messages (Table 3-3) appears on the LCD. If the connection is not successful, the LCD displays one of the Call Failure status messages (Table 3-3).

Disconnect

For dial backup applications, use this function when you want to disconnect an established call on a dial line. For leased backup applications, use this function to switch between the primary leased line and the backup leased line.

To access Disconnect from the Call Setup branch, make the following selection:

Call Setup> Dial Disconnect

F1

F2 F3

Select Disconnect.

F1

F2 F3

Disconnect Command Complete

Page 91 of the Paradyne 3910 user manual — Dial Standby/Return to Dial
Page 91 · click to enlarge
Page 91

For dial backup applications, the modem goes on-hook (hangs up) and the call is disconnected. The Command Complete status message appears.

To exit this function and remain in the Call Setup branch, press the key. To exit and return to the Top-Level menu, press the key.

Answer

For dial backup applications, Answer allows the modem to go off-hook, generate an answer tone, and begin the handshaking process with the calling modem. Use the Answer function when the Auto-Answer Ring Count configuration option is disabled. (Refer to the Line Dialer section in Chapter 4.)

For leased backup applications, Answer allows the modem to begin the handshaking process with the remote modem.

To access Answer from the Call Setup branch, make the following selections:

Call SetupAnswer

F1

F2 F3

Press the key until Answer appears. Select Answer.

F1

F2 F3

The modem goes off-hook and attempts to establish a connection in Answer mode. The Command Complete status message appears on the LCD.

To exit this function and remain in the Call Setup branch, press the key. To exit and return to the Top-Level menu, press the key.

Dial Standby/Return to Dial

When the modem is operating in Dial Backup mode (DialBckUp), Dial Standby and Return to Dial allow the modem to switch back and forth between primary leased-line and primary leased-line backup operation while still maintaining the backup connection (Figure 3-10). Switching between backup and primary leased-line operation can be performed manually or automatically. (Refer to the Leased Line section in Chapter 4 to enable the Automatic Dial Backup configuration option.)

DCP Operation · Answer Command Complete

Page 92 of the Paradyne 3910 user manual — F1
Page 92 · click to enlarge
Page 92

DIAL BACKUP LINE

Paradyne 3910 — DIAL BACKUP LINE diagram (page 92)
Fig. 12

FAILURE X X

MODEM MODEM LEASED-LINE

Figure 3-10. Dial Backup

Under normal backup conditions, when a problem occurs on the primary leased line, the modems establish a connection over the backup network.

Call SetupDial Standby

F1

F2 F3

When this occurs, Dial Standby appears on the LCD in the Call Setup menu branch. If you select Dial Standby, the modem switches back to the primary leased line while still maintaining the backup connection. As a result, Return_to_Dial appears on the LCD instead of Dial Standby.

Call SetupReturn_to_Dial

F1

F2 F3

If the primary leased line is unacceptable, select Return_to_Dial which switches the modem back to backup network operation (LCD displays Dial Standby). If, however, the primary leased line is operating properly, select Disconnect from the Call Setup branch to drop the dial backup connection. Also, if the primary leased-line operation is maintained uninterrupted for the amount of time specified in the Dial Standby configuration option, the dial backup network disconnects.

To access Dial Standby or Return to Dial from the Call Setup branch, make the following selections:

Call SetupDial Standby

F1

F2 F3

Press the key until Dial Standby or Return_to_Dial appears. Select the appropriate function.

496-13081-01

Page 93 of the Paradyne 3910 user manual — F1
Page 93 · click to enlarge
Page 93

Dial Standby Command Complete

F1

F2 F3

If the modem is operating in a Dial Backup mode, the Dial Standby function forces the modem to primary leased lines and the LCD displays the status message Command Complete.

Once the modem is in Dial Standby mode, Return_to_Dial appears on the LCD. Selecting this function forces the modem to the backup network and the LCD displays the status message Command Complete.

Change Directory

Change Directory allows you to enter or modify telephone numbers. The modem has nonvolatile memory locations that allow you to store up to 24 telephone numbers. Each directory location can accept up to 40 characters; this includes the telephone number and dial command modifiers. Any telephone number dialed using the DCP Dial command must appear in a directory location.

NOTE

If the modem is operating on leased lines and has a dial line attached for dial backup purposes, it is required that directory location 1 contain the telephone number used for dial backup.

To access Change Directory from the Call Setup branch, make the following selections:

Call Setup< Change_Directory

F1

F2 F3

Press the key until Change_Directory appears. Press any function key to select Change_Directory.

01:551234 Nxt

F1

F2 F3

The phone number listed in directory location 1 appears. Select Nxt to display other directory locations.

DCP Operation

Page 94 of the Paradyne 3910 user manual — F1
Page 94 · click to enlarge
Page 94

Entering Telephone Numbers and Dial Command Modifiers into Directory Locations

The following example uses an empty directory location for describing how to enter a telephone number. If you want to change an existing telephone number in any of the 24 directory locations, follow the same procedures.

To add a telephone number to a directory location, make the following selections:

2. Nxt

F1

F2 F3

Select Nxt until a blank directory appears on the LCD. (The cursor ( _ ) always appears in the first character position.)

Select F2 ( ) or F3 ( ) until the desired character is selected. This can be an alpha or numeric character.

2. Nxt

F1

F2 F3

Press the key to move the cursor to the next character position.

Continue this key sequence until the dial command modifiers and telephone number are entered. (Refer to Table 3-6 for a list of valid dial command modifiers.)

01:9W5556789 Nxt

F1

F2 F3

To save the number just entered, scroll to the next directory location by selecting Nxt. The number is now stored in nonvolatile memory.

Table 3-9 describes what can be entered in directory locations.

Page 95 of the Paradyne 3910 user manual — F1
Page 95 · click to enlarge
Page 95

Table 3-9 Valid Dial Command Modifiers

Dial command modifiers are parameters entered in the dial command string which specify how, when, and what number to dial. The following is a list of parameters the 391x Series modems recognize:

T — Tone (DTMF) dial. Any digit 0–9, *, or # can be dialed as tone.

P — Pulse dial. Only the digits 0–9 can be dialed in Pulse Dial mode.

that dial string. The modem defaults to the value set by the Dialer Type configuration option.

, — Pause. Causes the modem to pause before processing the next character in the dial string.

The length of this pause is determined by the setting of the Pause Time configuration option (refer to the Line Dialer configuration option group) or by the value held in S-Register S8.

W — Wait for tone dial. The modem waits for a second dial tone before processing the dial string.

This can be the initial dial tone or can be used when dialing through a tandem PBX.

R — Reverse Dial mode. Causes the originating modem to send out an answertone once it no

longer detects ringback. (Ringback is the ring you hear at the originating site when making a call.) The R modifier must be the last character in the dial string.

@ — Quiet answer. Wait for five seconds of silence after dialing the number. If the silence is not

detected, the modem sends the NO ANSWER result code to the DTE or displays the No Quiet Answer LCD status message.

! — Hook flash. Causes the modem to go on-hook for 0.5 seconds then return to off-hook.

; — Return to Command mode. Causes the modem to return to Command mode after dialing a

number without disconnecting the call.

Space — Ignored by the dial string, can be included to enhance readability.

– — Ignored by the dial string, can be included to enhance readability.

( ) — Ignored by the dial string, can be included to enhance readability.

← — End of Number. Hides all characters appearing on the LCD entered to the right of this

indicator.

Directory Status (Does Not Appear in North America)

Directory Status displays the status of each directory location.

To access Directory Status from the Call Setup branch, make the following selections:

Call Setup< Directory_Status

F1

F2 F3

Press the key until Directory_Status appears. Press any function key to select Directory_Status.

DCP Operation

Page 96 of the Paradyne 3910 user manual — Talk/Data Branch
Page 96 · click to enlarge
Page 96

Number Status Nxt 01:Allowed

F1

F2 F3

Select Nxt to display other directory locations.

The status of a directory location can be:

No Number The directory location is empty.

Allowed The number in this directory location may be dialed at this time.

Delayed The number in this directory location may be dialed later.

Forbidden The number in this directory location may not be dialed.

Delayed and Forbidden only appear in certain countries.

When a number is delayed, press the key to display the value of the delay in minutes.

The delayed and forbidden conditions can be cleared by power cycling the modem. This is actually the only way to reenable a forbidden number. Deleting a number from a directory location and reentering it into another directory location will not change the delayed or forbidden condition of this number.

Talk/Data Branch

The Talk/Data function is not available in TMp Control mode.

The Talk/Data branch of the Top-Level menu allows you to switch the modem between Talk mode and Data mode when manually dialing using either the DCP or an externally attached telephone.

To add an external telephone to your modem, use an external “Y” cable to connect the phone line to both the modem and the telephone (refer to Appendix C). This cable is not supplied with your modem.

On initial power-up, the modem is in Talk mode. When in Talk mode, the modem is disconnected and you are free to use the telephone. When in Data mode, the modem is connected and data can be transmitted or received. This function is not available for Model 3911 modems.

Status Configure PList Control Test SubHS Call_Setup Security Remote

“Status” · Tlk/Data

Page 97 of the Paradyne 3910 user manual — F1
Page 97 · click to enlarge
Page 97

The following sections describe three uses of the Talk/Data function.

Manual Dialing When the Remote Modem is Configured for Auto-Answer

NOTE

On the remote modem, the Line Current Disconnect configuration option (refer to the Line Dialer section in Chapter 4) must be set to Disable.

This configuration option does not appear on Models 3910-A1-401 and 3911-B1-001.

If you are originating a call using a telephone and the remote modem is configured for Auto-Answer, perform the following procedure.

Idle:19.2 Tlk/Data

F1

F2 F3

Press the key until Tlk/Data appears.

Lift the attached handset and dial the telephone number of the remote modem. When the remote modem answers, it transmits an answer tone.

Idle:19.2 Tlk/Data

F1

F2 F3

When you hear this tone, immediately select Tlk/Data and hang up the handset. This starts the handshaking sequence between your modem and the remote modem.

Online:19.2 > Call_Setup

F1

F2 F3

If this is successful, the modems are in Data mode and OnLine appears on the LCD.

DCP Operation

Page 98 of the Paradyne 3910 user manual — Security Branch
Page 98 · click to enlarge
Page 98

Manual Dialing When the Remote Modem is Configured for Manual Answer

NOTE

On both modems, the Line Current Disconnect configuration option (refer to the Line Dialer section in Chapter 4) must be set to Disable.

This configuration option does not appear on Models 3910-A1-401 and 3911-B1-001.

If you are originating a call using a telephone and the remote modem is configured for Manual Answer, perform the following procedure.

Once the remote telephone is answered by the remote user, you must both decide when to place the modems into Data mode. You must both select Tlk/Data at approximately the same time and hang up the handset to begin the handshaking sequence.

If the handshake is successful, the modems are in Data mode and OnLine appears on the LCD.

NOTE

If the remote modem is not a 3900 Series modem, then the remote user must consult that modem’s operator’s manual to perform a similar operation.

Once the modems are online, the status messages listed in Table 3-3 appear on the Top-Level display.

It is not necessary to specify an originating or answering modem when dialing via the DCP because the answering modem detects that it is receiving a ringing voltage and automatically defaults to Answer mode.

Security Branch

The Security branch allows you to create, edit, and save parameters that determine how the modem’s security is executed. For security procedures and configuration options, refer to Chapter 6, Dial Access Security.

Page 99 of the Paradyne 3910 user manual — Remote Branch
Page 99 · click to enlarge
Page 99

Remote Branch

The Remote branch of the Top-Level menu allows you to control the remote modem’s DCP using the local modem’s DCP. This function allows you to change configuration options and control test functions in a remote modem. Any changes made to configuration options while using the Remote branch are not saved until you exit the Remote branch. This function is only available when using either V.32 terbo, V.32bis, V.32, TMp, V.33, or V.29 modulation schemes.

Status Configure Plist Control Test SubHS Call_Setup Tlk/Data Security

Choose Address (TMp Control only)

Choose Password

(TMp only)

(Not in TMp Trib)

Secondary Prim (data blckd)

(ExitRem appears instead of Remote when

using Remote Mode)

The following conditions must be met before using the Remote branch:

  • A connection using either leased lines or the dial network must be established.
  • The Access from the Remote configuration option must be enabled in the remote modem.
  • In point-to-point networks, the Remote Access Password configuration option must be the same for both the local and remote modems. In multipoint networks the remote access password must be entered at the appropriate prompt.
  • For multipoint control modems, the network management address of the tributary modem must be entered at the appropriate prompt.

Remote DCP access is accomplished using either the primary or secondary channel (if available) of the VF line. Using the primary channel gives a much faster response time due to the higher data rate, but it also interrupts data flow because primary data is stopped when Remote mode is active. Once Remote mode is terminated, the primary channel is automatically made available for data transmission.

Unlike primary channel communications, the secondary channel operates at a slower data rate and does not interrupt data flow. (V.32 terbo, V.32bis, V.32, and TMp are the only modulations available for the secondary channel.)

DCP Operation · “Status” · Remote

Page 100 of the Paradyne 3910 user manual — F1
Page 100 · click to enlarge
Page 100

NOTE

When initiating a Remote function from a TMp tributary modem, primary channel operation is not available. Also, if the tributary modem is not on the control modem’s poll list, the error message No Trib Session appears when the function is executed.

To access the Remote branch, make the following selections:

Leased:19.2 < Security Remote

F1

F2 F3

Press the key until Remote appears. Select Remote.

NOTE

If a connection is not established between a local 3900 Series modem and a remote 3900 Series modem, the LCD displays Remote Mode Fail-No Circuit. Return to the Top-Level menu.

For Trellis Multipoint (TMp) control modems, you must specify the network management address of a tributary modem. The following display does not appear in point-to-point or Trellis Multipoint tributary modems.

Choose AddressEnt xxx

F1

F2 F3

The address field (xxx) displays the network management address of the modem to be accessed by the Remote function. The valid address field range is from 001 to 256.

To increment digits within the address field (xxx), use the and keys to position the cursor ( _ ) under the digit that will be incremented. Press the F2 ( ) key to increment the digit.

Press Enter (Ent) to select the modem that will be accessed by the Remote function.

Page 101 of the Paradyne 3910 user manual — F1
Page 101 · click to enlarge
Page 101

For Trellis Multipoint (TMp) modems (control or tributary), you must specify the remote access password of the modem that will be accessed by the Remote function. The following display does not appear in point-to-point modems.

Choose PasswordEnt yyyyyyyy

F1

F2 F3

The password field (yyyyyyyy) displays the remote access password of the modem to be accessed by the Remote function.

To increment digits within the password field (yyyyyyyy), use the and keys to position the cursor ( _ ) under the digit that will be incremented. Press the F2 ( ) key to increment the digit.

Press Enter (Ent) to select the modem that will be accessed by the Remote function.

Select Channel > Secondary

F1

F2 F3

Select Channel < Prim (data blckd)

F1

F2 F3

If operation over the secondary channel is desired, press any function key to select the secondary channel. Secondary channel only appears if using V.32 terbo, V.32bis, V.32 or TMp modulation. If operation over the primary channel is desired, press the key until primary displays and press any function key. Primary channel operation is not available when initiating a Remote function from a TMp tributary modem.

Online:14.4 Control ExitRem

F1

F2 F3

If the remote modem accepts the password and the entry is successful, the Top-Level menu of the remote modem appears on the local modem’s LCD. An appears in the upper right-hand corner indicating that what is displayed on your LCD is actually the Top-Level menu of the remote 391x Series modem. If the message Remote FP Busy appears, the remote modem’s front panel is already in Remote mode.

DCP Operation · or

Page 102 of the Paradyne 3910 user manual — DCP Operation
Page 102 · click to enlarge
Page 102

Configure PList Control Test SubHS Call_Setup ExitRem

The Top-Level menu of the remote 391x Series modem is similar to the local 391x Series modem with the following exceptions:

  • The Talk/Data and Security branches do not appear.
  • Change Directory is the only function available under the Call Setup branch.
  • Local Analog Loop and Remote Digital Loop do not appear under the T est branch when using the secondary channel. When using the primary channel, the T est branch does not appear.
  • Poll List Display is the only function available under the PList branch.
  • Exit Remote replaces Remote on the local modem’ s LCD.

To return to local modem operation, select ExitRem. Any changes made to configuration options in the remote modem are saved.

The following conditions can cause Remote branch access to fail:

  • The local modem is not able to communicate with the remote modem because of a poor dial network or leased-line connection, or the remote modem is not a 3900 Series modem. If this is the case, the status message No Response appears on the LCD.
  • If a connection is established but the remote modem’ s Access from Remote configuration option is disabled, then the status message Access Disabled appears on the LCD.
  • If a connection is established but the wrong password is stored, the status message Password Invalid appears on the LCD. This configuration option must be enabled by the remote user. (Refer to the Remote Access Password configuration option in Chapter 4.)
  • The Remote mode command displays Other Test Active if an Analog Loopback test is currently running.

“Status” · Status

Page 103 of the Paradyne 3910 user manual — F1
Page 103 · click to enlarge
Page 103

Diagnostic Control Panel Access

NOTE

This page of the manual is self supporting and can be removed to prevent unwanted knowledge of the DCP security access selections.

Use the DCP security access function to “lock” the DCP of any 391x Series modem and prevent unwanted user access. Two options are available for this function: Grant and Deny.

Grant allows any branch of the Top-Level menu to be accessed from the DCP. Deny only allows access to the Status branch of the Top-Level menu. All 391x Series modems are shipped from the factory with DCP access granted.

To access the Front Panel (DCP) Security Access function, perform the following:

Press the key three times.

Press the key twice.

Press the key once.

Frnt Panl Acces Grant Deny

F1

F2 F3

Select Grant to allow access or select Deny to lock DCP access.

Either selection results in a return to the Top-Level menu.

DCP Operation

Page 104 of the Paradyne 3910 user manual — Overview
Page 104 · click to enlarge
Page 104

DCP Configuration

Overview 4-1 Configure Branch 4-4 Editing and Saving a Configuration Option 4-5 Summary 4-8 Configuration Tables 4-9 DTE Interface 4-9 DTE Dialer 4-19 Line Dialer 4-25 Dial Line 4-30 Leased Line 4-33 V.42/MNP/Buffer 4-38 Test 4-46 Misc 4-48 Security 4-51

Overview

After installing a 391x Series modem, its software configuration options must be set using either the diagnostic control panel (DCP) or the AT command set. This chapter describes how to access and use the Configure branch of the Top-Level menu via the DCP.

The Configure branch accesses the Edit Area which is a work space where you view and change any configuration options (straps). These configuration options are loaded to the Edit Area from one of five configuration option areas: Active (Operating), Active (Saved), Customer 1, Customer 2, or Factory.

  • Active (Operating) is a configuration area containing configuration options currently used by the modem. When the modem is powered on or when a save is performed, the contents of Active (Saved) are loaded into Active (Operating). Any changes made using AT commands directly affect this configuration area.
  • Active (Saved) is a read from and write to configuration option area containing the most recently saved changes made to any configuration options. In the event of a power cycle or reset, the modem retrieves these settings from nonvolatile memory.
  • Customer 1 and Customer 2 are two additional read and write (changeable) configuration areas where you can create and store additional configurations for specific applications.
  • Factory is a read-only (unchangeable) configuration area containing six sets of predefined configuration options labeled Sync Leased , Async Leased , TMp (Trellis Multipoint), Async Dial , Sync Dial , and UNIX Dial . If Sync Leased or Async Leased is selected, you must choose either Answer or Originate mode. If TMp is selected, you must choose either Control or Trib (T ributary) mode. These sets contain the most commonly used configurations options for modems installed into these hardware environments. These predefined configuration options are intended to give you a head start and only require a minimum of changes to the default settings. Factory default settings are listed in Appendix F.
Page 105 of the Paradyne 3910 user manual — NOTE
Page 105 · click to enlarge
Page 105

NOTE

If you are using AT commands, a period of time can exist in which the contents of Active (Operating) and Active (Saved) differ. Once you issue an AT&W0 (write) command, however, the two storage areas are identical.

Figures 4-1 and 4-2 graphically display the interaction between the edit area and configuration areas as viewed from the perspective of the DCP and the AT command set.

CONTENTS OF Active (Saved) ARE AUTOMATICALLY COPIED TO Active (Operating) WHEN A SAVE IS COMMANDED VIA THE DCP, ON A RESET, OR ON POWER-UP.

Active (Operating) Active (Saved) Customer1 Customer2 Factory

(Answer/Originate) Async Leased

(Answer/Originate) TMp (Control/Trib) Async Dial Sync Dial UNIX Dial

Load Edit Area From

EDIT AREA ALLOWS YOU TO VIEW AND EDIT CONFIGURATION OPTIONS

ANY CHANGES MADE TO CONFIGURATION OPTIONS ARE SAVED TO Active (Saved), Customer1, OR Customer2

Figure 4-1. DCP Configuration Process

Sync Leased · Save · To

Page 106 of the Paradyne 3910 user manual — (AT&W0)
Page 106 · click to enlarge
Page 106

(ATZ0, ATZ3)

(ATZ1)

Leased Answer (AT&F2) Async

(AT&F1) Sync Leased

Originate (AT&F4) Async Leased

Leased Answer (AT&F5) TMp

Originate (AT&F6) TMp Trib

Control (AT&F7) Async Dial

(AT&F8) UNIX Dial

(AT&F3)

(AT&F0)

LOAD Active (Operating)

USING ATZ OR AT&F

COMMAND

NOTE

ON POWER-UP, Active (Saved) IS LOADED TO Active (Operating)

Active (Operating) CHANGES MADE USING ANY AT COMMAND IMMEDIATELY AFFECT MODEM OPERATION

USE AT&W COMMAND TO SAVE CHANGES TO Active (Saved), Customer1, OR Customer2

NOTE

THE AT&W COMMAND IS DISABLED IF THE Straps When Disconnected CONFIGURATION OPTION IS SET TO Reload

Active (Saved)

(AT&W0)

(AT&W1)

(AT&W2)

Figure 4-2. AT Command Configuration Process

Show 9 more labels / short text on this page
DCP Configuration · Active (Saved) · Customer1 · Customer2 · (ATZ2) Factory · Sync · Sync Dial · Customer1 · Customer2
Page 107 of the Paradyne 3910 user manual — Configure Branch
Page 107 · click to enlarge
Page 107

Configure Branch

The Configure branch of the Top-Level menu contains all of the modem’s configuration options (straps) which determine how the modem operates. These configuration options are accessed by scrolling down and across various levels of the Configure branch.

Status PList Control Test SubHS Call_Setup Tlk/Data Security Remote

Ld EditArea frm:

Activ (Operating) Active (Saved) Customer1 Customer2 Factory

Active (Saved) Customer1 Customer2

(Async only)

DTE_Interface Line_Dialer Leased_Line Test Security

DTE_Dialer Dial_Line V42/MNP/Buffer MIsc

Show 13 more labels / short text on this page
“Status” · Configure · TMp Sync_Dial · Sync_Leased · Async_Leased · UNIX_Dial Async_Dial · Choose Mode · Choose Mode · Control Trib · Answer Originate · Choose Function · Edit StrapGroup · Save
Page 108 of the Paradyne 3910 user manual — F1
Page 108 · click to enlarge
Page 108

The Configure branch consists of the following three levels:

  • Ld EditAr ea frm . Allows the selection of the Active (Operating), Active (Saved), Customer 1, Customer 2, and Factory configuration areas.
  • Choose Function . Allows you to make changes (Edit) to existing configuration options or write (Save) these changes to either the Active (Saved), Customer 1, or Customer 2.
  • Edit Strap Group . Contains the eight software configuration option groups that determine how the modem operates, plus the Security group, which can be viewed but not changed using this branch.

Editing and Saving a Configuration Option

The following example shows how to change the Remote Access Password using the DCP. (If you intend to access another 3900 Series modem via the Remote branch of the Top-Level menu, the Remote Access Password must be the same for both modems.) By following these procedures you learn how to load a factory preset configuration area (in this case, Sync Leased), how to edit a configuration option (Remote Access Password), and how to save changes to a configuration area (Active (Saved)). The shaded key indicates what key to press.

Leased:19.2 Status Configure

F1

F2 F3

Select Configure from the Top-Level menu.

F1

F2 F3

F1

F2 F3

Scroll across the LCD and select the Factory configuration area.

DCP Configuration · LdEditAreafrm > Activ(Operating) · LdEditAreafrm < Factory

Page 109 of the Paradyne 3910 user manual — F1
Page 109 · click to enlarge
Page 109
Ld Fact Preset> Sync_Leased

F1

F2 F3

Select Sync_Leased.

Choose ModeAnswer Originate

F1

F2 F3

Select Answer.

Choose FunctionEdit Save

F1

F2 F3

Select Edit.

Edit StrapGroup> DTE_Interface

F1

F2 F3

Edit StrapGroup Test Misc

F1

F2 F3

Scroll across the LCD and select the Misc configuration options group.

Page 110 of the Paradyne 3910 user manual — F1
Page 110 · click to enlarge
Page 110

StrapsWhenDisc > Nxt No_Change

F1

F2 F3

RemAccssPasswrdNxt 00000000

F2 F3

F1

Select Nxt until RemAccssPasswrd appears.

RemAccssPasswrdNxt 10000000

F1

F2 F3

Select the F2 ( ) key to increment password values.

RemAccssPasswrdNxt 10000000

F1

F2 F3

Press the key to move the cursor to the next position.

RemAccssPasswrdNxt 12345678

F1

F2 F3

Continue this sequence until you have entered the new password value.

DCP Configuration

Page 111 of the Paradyne 3910 user manual — Summary
Page 111 · click to enlarge
Page 111

To save the new password to a configuration area, make the following selections:

RemAccssPasswrdNxt 12345678

F1

F2 F3

Press the key to scroll up (twice).

Choose Function Edit Save

F1

F2 F3

Select Save.

Sav EditArea to > Active(Saved)

F1

F2 F3

Select a configuration area (Active (Saved), Customer 1, or Customer 2) to save the changes.

Select the key to exit to the Top-Level menu or select the key to remain in the Configure branch.

Summary

When using the DCP to edit configuration options, keep the following in mind:

  • Nxt has two functions. First, it indicates that more configuration options are available within that group. These are accessed by selecting Nxt (pressing F1) and scrolling down to the next configuration option. Second, it indicates that what is displayed on the LCD is the current setting. If you scroll left or right, Nxt disappears and reappears if a new value is selected.
  • End appears when you have scrolled down to the last configuration option available in that group. Selecting End returns you to the top of the configuration group. You are free to enter that group again or scroll left or right to the next configuration options group.
  • The key takes you one step up in the Configure branch each time it is pressed.
  • The key causes you to exit the Configure branch and return to the Top-Level menu. If any changes are made to configuration options, the DCP allows you to save these changes to either the Active (Saved), Customer 1, or Customer 2 configuration areas.
  • The and keys move selections across the LCD.
  • The function keys F1, F2, and F3 select the LCD choice that appears above that function key.
Page 112 of the Paradyne 3910 user manual — DTE Interface
Page 112 · click to enlarge
Page 112

Configuration T ables

The modem’s configuration options are arranged into nine groups based on functionality: DTE Interface (Table 4-1), DTE Dialer (Table 4-2), Line Dialer (Table 4-3), Dial Line (Table 4-4), Leased Line (Table 4-5), V.42/MNP/Buffer (Table 4-6), Test (Table 4-7), Misc (Table 4-8), and Security (Chapter 6).

Throughout these tables, two selections frequently appear on the LCD: Enable and Disable. Unless otherwise stated, Enable selects a configuration option and makes it available for use; Disable makes a configuration option unavailable for use.

NOTE

In some countries, the range of allowable values of some configuration options is restricted. The modem will accept any selection, but it will set the configuration option to the closest legal value. The actual value that is accepted by the modem is displayed when the F2 key is pressed to enter a selection.

DTE Interface

The DTE Interface configuration options contain EIA-232-D (CCITT V.24) and asynchronous character format information essential for maintaining a connection and for transmitting data between the DTE and the modem.

Table 4-1 shows each DTE Interface configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.

DCP Configuration

Page 113 of the Paradyne 3910 user manual — DCP Configuration
Page 113 · click to enlarge
Page 113

(1 of 10) DTE Interface Configuration Options

Async/Sync ModeSync Nxt Sync Async

Asynchronous/Synchronous Mode. Determines whether the modem operates in Asynchronous mode or Synchronous mode. If the AT command set is enabled and this configuration option is set to Sync, then the modem operates in Async mode when offline.

For Async Dial, Async Leased and UNIX Dial, Async is the factory default.

The AT commands for Async Mode are &M0 or &Q0. The AT commands for Sync Mode are &M1, &M2, &M3, or &Q1, &Q2, &Q3.

Async DTE Rate19200 Nxt 19200 57600 38400 14400 12000 9600 7200 4800 2400 1200 0–300

This configuration option only appears if Async/Sync Mode is configured for Async.

Asynchronous DTE Data Rate. Identifies the asynchronous DTE’s operating rate to the modem. Data rates from 57,600 bps to 300 bps are supported.

required, as well as a communications package which can take advantage of its 16-byte buffer. In addition, a 386 PC (25 MHz or faster) is required, and the RS232 cable length must be minimized to reduce capacitance.

Mode configuration option (see the V.42/MNP/Buffer section) is set to BufferMode.

The AT prefix determines Async DTE Rate.

Asyn #Data Bits8 Nxt 8 7 9(DirectMde) 6(DirectMde)

This configuration option only appears if Async/Sync Mode is configured for Async.

Asynchronous Number of Data Bits. Determines if the asynchronous data length is composed of 6, 7, 8, or 9 data bits. This data length excludes start, parity, and stop bits.

Sets data length to 8 data bits.

Sets data length to 7 data bits.

Sets data length to 9 data bits. Only valid when Error Control configuration option is set to Direct Mode.

Sets data length to 6 data bits. Only valid when Error Control configuration option is set to Direct Mode.

size must equal 10 bits. Total character size consists of start, data, parity, and stop bits. V.25bis Async must use 7 data bits with even parity and 1 stop bit. The total character size for Error Control mode, Direct mode, or Buffer mode must be 11 bits or less.

The AT prefix determines the async character length.

Show 5 more labels / short text on this page
Table 4-1 · 8 · 7 · 9(DirectMode) · 6(DirectMode)
Page 114 of the Paradyne 3910 user manual — DCP Configuration
Page 114 · click to enlarge
Page 114

(2 of 10) DTE Interface Configuration Options

Asyn Parity BitNone Nxt None Even Odd Mark Space

This configuration option only appears if Async/Sync Mode is configured for Async.

Asynchronous Parity Bit. Determines the type of asynchronous parity bit. The parity of the DTE must match the parity of the modem. Parity options include None, Even, Odd, Mark, or Space.

No parity bit is used.

Parity bit is set so that total number of 1’s in data bits plus parity bit is even.

Parity bit is set so that total number of 1’s in data bits plus parity bit is odd.

Parity bit is always set to 1. Only valid if Async #Data Bits configuration option is set to 7.

Parity bit is always set to 0. Only valid if Async #Data Bits configuration option is set to 7.

size must equal 10 bits. Total character size consists of start, data, parity, and stop bits. V.25bis Async must use 7 data bits with even parity and 1 stop bit. The total character size for Error Control mode, Direct mode, or Buffer mode must be 11 bits or less.

The AT prefix determines parity of the async character.

Asyn #Stop Bits1 Nxt 1 2

This configuration option only appears if Async/Sync Mode is configured for Async.

Asynchronous Number of Stop Bits. Selects 1 or 2 bits to signal the end of an asynchronous character.

size must equal 10 bits. Total character size consists of start, data, parity, and stop bits. V.25bis Async must use 7 data bits with even parity and 1 stop bit. The total character size for Error Control mode, Direct mode, or Buffer mode must be 11 bits or less.

The AT prefix determines the number of stop bits via autobauding.

Show 7 more labels / short text on this page
DCP Configuration · Table 4-1 · None · Even · Odd · Mark · Space
Page 115 of the Paradyne 3910 user manual — DCP Configuration
Page 115 · click to enlarge
Page 115

(3 of 10) DTE Interface Configuration Options

DTR ActionIgnore Nxt Ignore Stndrd_RS232 CntrlsOnHook CntrlsTxMute

Data Terminal Ready Action. DTR is a signal from the DTE to the modem indicating that the DTE is connected and ready for operation.

Modem assumes DTR is always ON. This is used when the DTE does not provide DTR.

Allows the DTE to control DTR to the modem as specified in EIA-232-D and CCITT V.24 specifications. If this signal is not present, the modem will not answer or dial.

Required for applications in which the host processor must reset itself for the next session before the current session is terminated. When selected, the modem does not disconnect from the VF line during an active call until DTR is lowered by the attached DTE. This setting is ignored if the modem is commanded to disconnect from its own front panel or by the COMSPHERE 6700 Series Network Management System.

Controls Transmitter Mute

Mutes the transmitter whenever DTR drops on the DTE interface. This selection can be used on the answer side modem to force the originate modem to initiate a dial backup.

must provide DTR to dial or answer a call.

(Data Terminal Ready). If DTE Dialer Type configuration option is set to DTR=Direct 1, then DTR Action behaves as CT108/1 (Connect Data Set to Line).

The AT command for Ignore is &D0. The AT commands for Standard RS232 are &D1 or &D2. The AT command for CntrlsOnHook is &D4 The AT command for CntrlsTxMute is &D5.

Show 4 more labels / short text on this page
Table 4-1 · Ignore · Standard RS232 · Controls On-Hook
Page 116 of the Paradyne 3910 user manual — DCP Configuration
Page 116 · click to enlarge
Page 116

(4 of 10) DTE Interface Configuration Options

DSR ControlStndrd_RS232 Nxt Stndrd_RS232 Forced_On WinkWhenDisc Follows_DTR On_Early Delay_ToData

Data Set Ready Control. DSR is a signal from the modem to the DTE indicating the modem is connected and ready for operation.

Allows the modem to control DSR to the DTE. The modem raises DSR when it begins the handshake process. DSR lowers upon disconnect. The modem is not ready to receive data until DSR, CTS, and LSD are active. An ON state indicates to the DTE that the modem is ready to receive data. An OFF state indicates that the modem is not ready to receive data, and the DTE will not send data to the modem. During a Local Analog Loop and a Remote Digital Loop, DSR is ON.

Forces DSR output ON constantly. This is usually used for leased-line applications and when the DTE requires DSR to always be ON.

Wink When Disconnect

DSR is normally forced ON, but is turned OFF for 1 to 2 seconds upon a disconnect.

When the modem receives DTR from the DTE, it sends DSR to the DTE.

DSR is low when the modem is in the idle state. DSR goes high immediately upon a command to enter Data mode. This setting is required for some modem pooling applications.

Delay to Data

Operation is similar to the Standard RS232 except that DSR does not turn ON until the modem enters Data mode. Normally, the modem raises DSR when it begins the handshaking process. Use this setting when the DTE cannot operate with a long DSR-to-CTS delay (common for V.32bis modulation) or when dial access security is enabled and requires a DTE-side password entry. Often, the DTE cannot accept the long delay between DSR and CTS turning ON due to the remote user entering the DTE-side password.

The AT command for Forced On is &S0. The AT command for Standard RS232 is &S1. The AT command for Wink When Disconnect is &S2. The AT command for Follows DTR is &S3. The AT command for On Early is &S4. The AT command for Delay to Data is &S5.

Show 6 more labels / short text on this page
DCP Configuration · Table 4-1 · Standard RS232 · Forced On · Follows DTR · On Early
Page 117 of the Paradyne 3910 user manual — DCP Configuration
Page 117 · click to enlarge
Page 117

(5 of 10) DTE Interface Configuration Options

RTS ActionStndrd_RS232 Nxt Stndrd_RS232 Ignore Sim_Cntl_Car Cntl_Car

Request-to-Send Action. RTS is a signal from the DTE indicating the DTE has data to send.

Allows the DTE to control RTS to the modem in normal EIA-232-D operation. RTS must be ON for the DTE to transmit to the modem.

Modem assumes RTS is always ON. Use this selection when the DTE does not provide RTS to the modem.

Simulated Control Carrier

RTS input controls the remote modem’s LSD signal. This is used for DTEs that require Line Signal Detect (LSD) to toggle ON and OFF to simulate half-duplex operation. If RTS Action is set to simulated control carrier, then the remote modem’s LSD Control configuration option must be set to Simulated Control Carrier. Simulated Control Carrier conforms to V.13 specifications. This setting is ignored when the modem is configured for Asynchronous mode and RTS/CTS flow control is selected.

Allows the DTE’s RTS signal to control the modem’s carrier signal. When RTS is ON, carrier is present on the VF line. When RTS turns OFF, carrier is not present. This is only valid for V.29 and V.27bis leased-line modulations. Auto Dial Backup is always disabled for this setting.

The AT command for Standard RS232 is &R0. The AT command for Ignore is &R1. The AT command for Simulated Control Carrier is &R2. The AT command for Control Carrier is &R3.

RTS Antistream10sec Nxt 10sec Disable 30sec 1min 2min 3min 5min

This configuration option only appears in TMp Tributary mode, or if RTS_Action is configured for Cntl_Car (V.29 and V.27bis).

Request-to-Send Antistreaming. If enabled, the operation of the antistreaming function is as follows. If RTS is ON for a period exceeding the selected time, the modem will take over control of the carrier and will force it OFF. The modem will also force CTS OFF during this time. This condition will stay in effect until the DTE turns RTS OFF. After this, the next time the DTE turns RTS ON, carrier will be turned ON and the RTS timer will start again.

The antistreaming function is not in effect.

10 sec, 30 sec, 1 min, 2 min, 3 min, 5 min

Enables the antistreaming function and sets the maximum ON time for RTS before antistreaming control takes effect.

The AT command is S-Register S72=n, where n is 0 for Disable, 1 for 10 sec, 2 for 30 sec, 3 for 1 min, 4 for 2 min, 5 for 3 min, and 6 for 5 min.

Show 5 more labels / short text on this page
Table 4-1 · Standard RS232 · Ignore · Control Carrier · Disable
Page 118 of the Paradyne 3910 user manual — DCP Configuration
Page 118 · click to enlarge
Page 118

(6 of 10) DTE Interface Configuration Options

CTS ControlStndrd_RS232 Nxt Stndrd_RS232 Forced_On WinkWhenDisc Follows_DTR Follows_RTS40

Clear-to-Send Control. CTS is a signal from the modem to the DTE indicating that it can accept data from the DTE.

In Synchronous mode, forces the state of CTS to follow the state of RTS in normal EIA-232-D operation. The minimum time that elapses between CTS and RTS is determined by the RTS/CTS Delay configuration option. Use this setting for most synchronous applications. In AT Command mode, CTS goes low just prior to DSR going active and goes high when the modem enters Data mode. This operation prevents losing data in applications which begin transmitting as soon as DSR and CTS are both active.

CTS is forced ON at all times. Use this selection for most asynchronous applications.

Wink When Disconnect

CTS is normally forced ON, but is turned OFF for 1 to 2 seconds upon a disconnect. Use this for most UNIX applications.

The state of CTS follows the state of DTR. When DTR turns ON, CTS turns ON. When DTR turns OFF, CTS turns OFF.

The state of CTS follows the state of RTS. When RTS turns ON, CTS turns ON. When RTS turns OFF, CTS turns OFF.

of the setting of CTS Control.

The AT command for Forced On is \D0. The AT command for Standard RS232 is \D1. The AT command for Wink When Disconnect is \D2. The AT command for Follows DTR is \D3. The AT command for Follows RTS is \D4.

RTS/CTS Delay0msec Nxt 0msec 10msec 50msec 150msec 600msec

Request-to-Send/Clear-to-Send Delay. RTS/CTS Delay sets the delay time between the modem receiving RTS from the DTE and the modem sending CTS to the DTE.

have a short delay between the time the DTE raises RTS and the time the modem presents CTS to allow the DTE to send data.

options must be set to Stndrd RS232. If RTS Action is set to Ignore, RTS is always ON and this configuration option has no effect.

The AT command is S-Register S26=n, where n is a value from 0 to 255 in 10 millisecond increments.

Show 6 more labels / short text on this page
DCP Configuration · Table 4-1 · Standard RS232 · Forced On · Follows DTR · Follows RTS
Page 119 of the Paradyne 3910 user manual — DCP Configuration
Page 119 · click to enlarge
Page 119

(7 of 10) DTE Interface Configuration Options

LSD ControlStndrd_RS232 Nxt Stndrd_RS232 Forced_On WinkWhenDisc Follows_DTR Sim_Cntl_Car =DTR/DiscOFF

Line Signal Detect Control. LSD is a signal indicating that the carrier signal is being received from the remote modem. It is normally turned OFF to the DTE when the power level of the received carrier signal drops below the carrier detect threshold.

LSD is ON when the modem detects the remote modem’s carrier signal. LSD turns OFF when the carrier signal strength drops below carrier detect threshold.

Forces LSD to be ON at all times.

Wink When Disconnect

LSD is normally forced ON, but can be turned OFF for 1 to 2 seconds upon a disconnect. This is used for UNIX DTEs.

The state of LSD follows the state of DTR. When DTR turns ON, LSD turns ON. When DTR turns OFF, LSD turns OFF.

Simulated Control Carrier

LSD follows the state of RTS of the remote DTE via the V.13 simulated control carrier signaling. This is required for hosts that cannot support full-duplex operation. If LSD Control is set to simulated control carrier, then the RTS Action configuration option on the remote modem must be set to Simulated Control Carrier.

The state of LSD follows the state of DTR except when disconnecting once a connection is established. In this instance, DTR remains ON and LSD turns OFF. DTR must then toggle OFF and then ON again for LSD to turn ON. This setting is required for AT&T DATAKIT dial-out applications.

Stndrd_RS232.

The AT command for Forced On is &C0. The AT command for Standard RS232 is &C1. The AT command for Wink When Disconnect is &C2. The AT command for Follows DTR is &C3. The AT command for Simulated Control Carrier is &C4. The AT command for =DTR/Disconnect OFF is &C5.

Show 5 more labels / short text on this page
Table 4-1 · Standard RS232 · Forced On · Follows DTR · =DTR/Disconnect OFF
Page 120 of the Paradyne 3910 user manual — DCP Configuration
Page 120 · click to enlarge
Page 120

(8 of 10) DTE Interface Configuration Options

TX Clock SourceInternal Nxt Internal External RXC_Loop

This configuration option only appears if Async/Sync Mode is configured for Sync.

Transmit Clock Source. Determines the source of timing for synchronous data transmitted from the modem to the analog channel.

The transmit data’s clock source is derived from the modem’s internal clock. This clock is available as an output on Pin 15 (TXC) of the EIA-232-D interface.

The transmit data’s clock source is provided by the DTE on Pin 24 (XTXC) on the EIA-232-D interface.

Receive Clock Loop

The modem’s transmit clock is derived from its received analog signal. The derived clock is available as an output on Pin 15 (TXC) of the EIA-232-D interface.

The AT command for Internal is &X0. The AT command for External is &X1. The AT command for RXC Loop is &X2.

Bakup_TXClk_SrcInternal Nxt Internal External RXC_Loop

This configuration option only appears in customized installations in which the Dual_Leased_Ln is configured for Enable and Async/Sync Mode is Sync.

Backup Transmit Clock Source. Selects the clock reference source when operating in the Dual Leased Line Mode. This is a special mode in which one leased line is used to back up another.

The transmit data’s clock source is derived from the modem’s internal clock. This clock is available as an output on Pin 15 (TXC) of the EIA-232-D interface.

The transmit data’s clock source is provided by the DTE on Pin 24 (XTXC) on the EIA-232-D interface.

Receive Clock Loop

The modem’s transmit clock is derived from its received analog signal. The derived clock is available as an output on Pin 15 (TXC) of the EIA-232-D interface.

XTXC Clamps TXCEnable Nxt Enable Disable

This configuration option only appears if TX Clock Source is configured for External.

External Transmit Clock Clamps Transmit Clock. Allows the modem’s TXC output (Pin 15 on the EIA-232-D interface) to be clamped OFF when TX Clock Source is configured for External.

TXC is clamped off when TX Clock Source is configured for External.

TXC continues to be provided when TX Clock Source is configured for External.

The AT command is S-Register S71=n, where n is 0 for Enable and 1 for Disable.

Show 8 more labels / short text on this page
DCP Configuration · Table 4-1 · Internal · External · Internal · External · Enable · Disable
Page 121 of the Paradyne 3910 user manual — DCP Configuration
Page 121 · click to enlarge
Page 121

(9 of 10) DTE Interface Configuration Options

CT111_Rate CntlDisable Nxt Disable Fallback1 Fallback2

CT111 Rate Control. Allows the DTE to control modem rate via Pin 23 of the EIA-232-D interface. This configuration option determines the effect of the DTE Rate control signal. CT111 is also known as CH on the EIA-232-D interface.

Disregards CT111 Rate Control.

Forces the modem to decrease its configured data rate to the next lower data rate when CT111 is OFF. Valid only for V.32bis, V.33, V.29 modulation. Modem will only fall back within the same modulation scheme. When CT111 turns ON, the modem returns to its previous data rate.

Fallback2 (Not available for TMp tributaries)

Forces the modem to decrease two data rates while remaining in the same modulation scheme. When CT111 turns ON, the modem returns to its previous data rate.

operation, disable the V.32bis Autorate and V.32bis Automode configuration options.

The AT command is S-Register S61=n, where n is 0 for Disable, 1 for Fallback1, and 2 for Fallback2.

DTE_Rate=VFDisable End Disable Enable

This configuration option does not appear if Async/Sync is configured for Sync.

DTE Rate = VF. Forces the DTE’s data rate to be equal to the VF (telephone line) data rate.

The data rate of the connection between the DTE and modem is the value of the Async DTE Rate configuration option.

The data rate between the DTE and modem is the same as the modem’s VF data rate. As a result, when the modem is in Data mode, the speed of the data passed between the modem and DTE occurs at the VF data rate.

The AT command is S-Register S90=n, where n is 0 for Disable and 1 for Enable.

Show 5 more labels / short text on this page
Table 4-1 · Disable · Fallback1 · Disable · Enable
Page 122 of the Paradyne 3910 user manual — DTE Dialer
Page 122 · click to enlarge
Page 122

Table 4-1 (10 of 10) DTE Interface Configuration Options

Extend Main Ch.: Disable Nxt Disable Enable

Primary data can only be extended one link.

Extend Main Channel. This configuration option supports extended diagnostics. Specifies whether there is main (primary) channel connectivity between the modem’s DTE ports and the DTE ports of modems one level below (downstream) or above (upstream) in the diagnostic network.

If this configuration option is set to Enable on a port of a tributary modem, test mode is propagated to the modems downstream when test mode goes ON for that port.

If this configuration option is set to Disable on a port of a tributary modem, test mode is not propagated for that port and primary channel data is clamped when in test mode.

number where the main (primary) channel is extended.

Upstream PortPort1 End Port1 Port2 Port3 Port4 Port5 Port6 Port7 Port8

This configuration option only appears on a control modem when the Extended Main Channel is enabled.

Upstream Port. When an extended control modem’s main (primary) channel is connected to a tributary modem that is one link above it in the diagnostic network, this configuration option is set to the port number to which it is connected on the tributary modem.

DTE Dialer

The DTE Dialer configuration options establish the DTE-to-modem protocol for call establishment and control.

Table 4-2 shows each DTE Dialer configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.

DCP Configuration · Enable · Disable

Page 123 of the Paradyne 3910 user manual — AT
Page 123 · click to enlarge
Page 123

(1 of 5) DTE Dialer Configuration Options

DTE Dialer TypeDisable Nxt Disable AT V25bis_Async V25bis_Bsync V25bis_HDLC DTR=Direct1 AT&T_Exclusv

Data Terminal Equipment Dialer Type. Identifies to the modem the type of dialing method and protocol used by the DTE.

Disables any type of DTE dialing method. Dialing can only be performed using the DCP’s Dial command or attached telephone.

AT

Allows AT command protocol to be used as a method for entering commands and dialing when used in an asynchronous application. This is the only valid setting for leased-line applications. The modem will not respond to AT commands if DTE Dialer Type is not set to AT.

V.25bis Async

Selects V.25bis Async as the dialing method and protocol used by the modem. The character length must be 7 data bits with even parity and 1 stop bit.

V.25bis Bsync

Selects V.25bis Bsync as the dialing method and protocol used by the modem. This is also known as character-oriented protocol. This framing protocol uses two synchronous control characters and a start-of-text control character before the text block and an end-of-text control character after the text block. The correct character structure for V.25bis Bsync dialing is 7 data bits, Odd parity, and 1 stop bit. If the modem is in Asynchronous mode, enter the following command string to configure it for V.25bis Bsync dialing: AT&F&D1&S1&M233&W. If the modem is already configured for synchronous operation, perform the following to set the character format: (1) use the modem’s front panel to access the Async/Sync Mode configuration option and set it to Async; (2) scroll down until the Asyn #Data Bits configuration option appears and set it to 7 data bits; (3) scroll down and set the Asyn Parity Bit configuration option to Odd; (4) scroll through the DTE Interface group until the Async/Sync Mode configuration option appears and set it to Sync; (5) move up one level in the menu tree or move to the Top-Level menu, and follow the LCD messages to save the new modem settings.

V.25bis HDLC

Selects V.25bis HDLC as the dialing method and protocol used by the modem. This is also known as bit-oriented protocol. This framing protocol uses flag, address and control characters before the text block and a frame sequence check and flag after the text block.

Allows the modem to automatically dial the number stored in directory location 1 whenever DTR turns ON. DTR dialing cannot be used if dial access security is enabled.

Enables a subset of the proprietary AT&T command set, which is required for some applications that use AT&T equipment. Currently, the only application supported is AT&T DATAKIT.

The AT commands for AT are &M0, &M1, &M3 or &Q0, &Q1, &Q3. The AT commands for DTR=Direct1 dialing are &M2 or &Q2.

Show 4 more labels / short text on this page
Table 4-2 · Disable · DTR=Direct1 · AT&T Exclusive
Page 124 of the Paradyne 3910 user manual — DCP Configuration
Page 124 · click to enlarge
Page 124

(2 of 5) DTE Dialer Configuration Options

AT Escape Char043 ASCI Nxt 043 ASCI

This configuration option only appears if DTE Dialer Type is configured for AT.

AT Escape Character. The escape sequence (+++) allows you to move from Data mode to Command mode. Use the AT Originate (ATO) command to return to Data mode. The ASCII value of the escape character (43 ASCII) can be set to any ASCII value from 0 ASCII to 255 ASCII. However, the escape character is disabled if a value greater than 127 ASCII is entered. When disabled, the call must be disconnected to return to Command mode.

The AT command is S-Register S2=n, where n is a value from 0 to 127. The AT command to disable is S-Register S2=n where n is a value from 128 to 255. (When disabled, the modem cannot return to Command mode unless disconnected.)

Escape GuardTim1sec Nxt 1sec 200msec 400msec 600msec 800msec 2sec

This configuration option only appears if DTE Dialer Type is configured for AT.

Escape Guard Time. Determines the length of the required pause before and after the escape sequence is issued. The guard time prevents the modem from interpreting data as the escape sequence characters.

The AT command is S-Register S12=n, where n is a value from 0 to 255 in 20 millisecond increments.

BreakForceEscapDisable Nxt Disable Enable

This configuration option only appears if DTE Dialer Type is configured for AT.

Break Forces Escape. Determines whether or not the modem should enter Command mode when it receives a break character from the DTE.

A break character is sent to the remote end.

Modem escapes into AT Command mode, and a break character is not sent to the remote end.

The AT commands for Enable are \K0, \K2, or \K4. The AT commands for Disable are \K1, \K3, or \K5.

CommandCharEchoEnable Nxt Enable Disable

This configuration option only appears if DTE Dialer Type is configured for AT.

Command Character Echo. Controls whether or not characters are echoed back to the DTE when the modem is in Command mode.

The AT command for Disable is E0. The AT command for Enable is E1.

Show 4 more labels / short text on this page
DCP Configuration · Table 4-2 · Disable · Enable
Page 125 of the Paradyne 3910 user manual — DCP Configuration
Page 125 · click to enlarge
Page 125

(3 of 5) DTE Dialer Configuration Options

CarriageRtn Char013 ASCI Nxt 013 ASCI

This configuration option only appears if DTE Dialer Type is configured for AT.

Carriage Return Character. Allows you to change the ASCII character used to terminate an AT command to any ASCII value from 0 to 127.

The AT command is S-Register S3=n, where n is a value from 0 to 127.

Backspace Char008 ASCI Nxt 008 ASCI

This configuration option only appears if DTE Dialer Type is configured for AT.

Backspace Character. Sets the character used to perform a backspace in Command mode.

The AT command is S-Register S5=n, where n is a value from 0 to 127.

Linefeed Char010 ASCI Nxt 010 ASCI

This configuration option only appears if DTE Dialer Type is configured for AT.

Line Feed Character. Sets the character used to perform a line feed in Command mode for responses from the modem.

The AT command is S-Register S4=n, where n is a value from 0 to 127.

Result CodesEnable Nxt Enable Disable EnableInOrig

This configuration option only appears if DTE Dialer Type is configured for AT.

Result Codes. Result codes are informational messages (such as Connect and Ring) sent from the modem and displayed on the asynchronous DTE terminal. (For a list of Result Codes, refer to Table 5-1 in Chapter 5, AT Commands and S-Registers.)

Modem sends result codes to the DTE.

Modem does not send result codes to the DTE.

Enable in Originate

For UNIX applications, enable result codes only on the originating modem. This prevents the DTE on the answer side from interpreting result codes as login attempts.

The AT command for Enable is Q0. The AT command for Disable is Q1. The AT command for Enable in Originate mode is Q2.

Table 4-2 · Enable · Disable

Page 126 of the Paradyne 3910 user manual — DCP Configuration
Page 126 · click to enlarge
Page 126

(4 of 5) DTE Dialer Configuration Options

ExtendResltCodeEnable Nxt Enable Disable Add/EC Add/V42,MNP Use_DTE_Rate

This configuration option only appears if DTE Dialer Type is configured for AT.

Extended Result Codes. Informational messages such as VF data rate and Error Control are displayed with the result codes. (For a list of Extended Result Codes, refer to Table 5-1 in Chapter 5, AT Commands and S-Registers.)

NO DIALTONE, BUSY, NO ANSWER, and CONNECT xxxx (xxxx = VF data rate) appear along with result codes listed in Table 5-1 in Chapter 5.

Only OK, CONNECT, RING, NO CARRIER, and ERROR result codes appear.

Places the EC suffix after the result code text if error control is used. For example, CONNECT 9600/EC.

Add/V.42 or /MNP

Places either the /V.42 or /MNP suffix after the result code text if data compression is used. For example, CONNECT 9600/V42b.

Use DTE Rate

Allows the DTE rate to be displayed in the Connect message instead of the line rate. This feature is required in some modem pooling applications.

Busy Detect configuration option is enabled.

The AT command for Disable is X0. The AT commands for Enable are X1, X2, X3, or X4. The AT command for Add/EC is X5. The AT command for Add/V42,MNP is X6. The AT command for Use DTE Rate is X7.

ResultCode FormWords Nxt Words Numbers (1) Numbers (2)

This configuration option only appears if DTE Dialer Type is configured for AT.

Result Codes Format. Controls whether or not result codes appear as words or as numeric codes. Some DTEs do not recognize Result Codes as words; therefore, numbers are required. The Numbers (2) format is required for some modem pooling applications. (For a list of Result Codes, refer to Table 5-1 in Chapter 5, AT Commands and S-Registers.)

The AT command for Numbers (1) is V0. The AT command for Words format is V1. The AT command for Numbers (2) is V2.

Show 5 more labels / short text on this page
DCP Configuration · Table 4-2 · Enable · Disable · Add/EC
Page 127 of the Paradyne 3910 user manual — DCP Configuration
Page 127 · click to enlarge
Page 127

(5 of 5) DTE Dialer Configuration Options

AT Cmnd ModeNormal Nxt Normal No_ERROR NoStrapOrERR

This configuration option only appears if DTE Dialer Type is configured for AT.

AT Command Mode. Determines how the modem responds to valid and invalid AT commands.

Allows normal operation of the AT command set. The modem acts upon all valid AT commands and issues the ERROR result code for invalid commands. If a string with multiple commands is entered, then an invalid command within that string will prevent the execution of subsequent valid commands.

Operates similar to Normal mode, however, the modem does not issue an ERROR result code for invalid commands. When an invalid command is encountered, the modem ignores it and issues the OK result code. If a string with multiple commands is entered, then an invalid command within that string will not prevent the execution of subsequent valid commands.

No Strap or ERROR

Ignores all AT commands (including valid commands) that cause a configuration option to change. Only non-configuring commands (for example ATD, ATA, and ATI) are executed; the ERROR result code is never returned.

However, it can be changed by selecting a factory preset configuration via the DCP.

The AT command is S-Register S84=n, where n is 0 or 231 for Normal, 1 or 232 for No ERROR, and 2 or 233 for No Strap or ERROR.

V25bis CodingASCII Nxt ASCII EBCDIC

This configuration option only appears if DTE Dialer is configured for V.25bis HDLC or V.25bis Bsync.

V.25bis Coding. Identifies to the modem whether the DTE is using ASCII code or EBCDIC code for V.25bis commands. The modem responds to the DTE using the same coding.

The AT command is S-Register S62=n, where n is 0 for ASCII or 1 for EBCDIC.

V25bis IdleFillMark Nxt Mark Flag

This configuration option only appears if DTE Dialer is configured for V.25bis HDLC.

V.25bis Idle Fill. Determines whether a mark or flag is used as an idle fill character for the DTE. The modem responds to the DTE using the same idle fill.

The AT command is S-Register S63=n, where n is 0 for Mark or 1 for Flag.

V25b NewLineChrCR+LF End CR+LF CR LF

This configuration option only appears if DTE Dialer is configured for V.25 bis Async.

V.25bis New Line Character. Sets the modem for the command line terminator used by the DTE in V.25bis Async mode. The modem responds to the DTE using the same line terminator.

The AT command is S-Register S64=n, where n is 0 for carriage return and line feed, 1 for carriage return, or 2 for line feed.

Table 4-2 · Normal · No ERROR

Page 128 of the Paradyne 3910 user manual — Line Dialer
Page 128 · click to enlarge
Page 128

Line Dialer

The Line Dialer configuration options establish parameters used by the modem to answer or originate calls.

Table 4-3 shows each Line Dialer configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.

(1 of 5) Line Dialer Configuration Options

AutoAnswerRing#1 Nxt 1 Disable 2 4 6 8 10

Auto-Answer Ring Count. Determines the number of rings necessary before the answering modem answers an incoming call. For example, if this option is set to 2, then the answering modem answers after the second ring.

If selected, the modem must be answered using either the DCP’s Answer command or Tlk/Data function or via AT commands. Refer to Talk/Data in Chapter 3, DCP Operation, for more on Manual Answer.

from 1 to 255 rings.

The AT command for Disable is S0=0. The AT command is S-Register S0=n, where n is a ring count from 1 to 255.

Dialer TypeTone Nxt Tone Pulse

Dialer Type. Selects either tone (DTMF) dialing or pulse (rotary) dialing mode.

The AT command for Tone is T. The AT command for Pulse is P.

DialTone DetectEnable Nxt Enable Disable

Dial Tone Detect. Sets the modem for dial tone detection (enable) or blind dialing (disable).

Modem disconnects the call if a dial tone is not detected within 10 seconds and displays No Dial Tone on both the LCD and asynchronous DTE terminal.

Modem dials a call whether or not it detects a dial tone on the line. This is known as blind dialing. The period of time the modem waits before dialing is specified in the Blind Dial Pause configuration option.

The AT commands for Disable are X0, X1, and X3. The AT commands for Enable are X2, X4, X5, X6, and X7.

Show 5 more labels / short text on this page
DCP Configuration · Table 4-3 · Disable · Enable · Disable
Page 129 of the Paradyne 3910 user manual — DCP Configuration
Page 129 · click to enlarge
Page 129

(2 of 5) Line Dialer Configuration Options

Blind Dial Pause2sec Nxt 2sec 4sec 6sec 8sec 10sec 20sec

This configuration option only appears when Dial Tone Detect is configured for Disable.

Blind Dial Pause. Determines how long the modem waits before dialing a telephone number when Dialtone Detect is disabled.

The AT command is S-Register S6=n, where n is from 2 to 255 in 1-second increments.

BusyTone DetectEnable Nxt Enable Disable

Busy Tone Detect. Sets the modem to monitor for Busy Tone (Enable) or ignore Busy Tone (Disable).

configuration option can be disabled and the modem ignores all busy tones.

The AT commands for Disable are X0, X1, and X2. The AT commands for Enable are X3, X4, X5, X6, and X7.

“,” Pause Time2sec Nxt 2sec 4sec 6sec 8sec 10sec 20sec

Pause Time. Determines the number of seconds the modem pauses when it encounters a comma (,) in the dial command string.

display from 0 to 255 seconds.

The AT command is S-Register S8=n, where n is from 0 to 255 in 1-second increments.

NoAnswer Timout45sec Nxt 45sec 30sec 60sec 120sec

No Answer Abort Time-out. Determines the number of seconds an originating modem waits before abandoning a call attempt when no answer tone is received.

from 1 to 255 seconds.

The AT command is S-Register S7=n, where n is from 1 to 255 in 1-second increments.

Table 4-3

Page 130 of the Paradyne 3910 user manual — DCP Configuration
Page 130 · click to enlarge
Page 130

(3 of 5) Line Dialer Configuration Options

Fast DisconnectDisable Nxt Disable Enable

Fast Disconnect. Allows the modem to disconnect immediately after receiving a disconnect command from a local DTE or its own diagnostic control panel.

The modem follows its normal disconnect sequence by issuing a cleardown sequence or long space disconnect. This is also known as a graceful disconnect since the other modem receives advance notice of a disconnection.

Use this setting if the DTE requires that the modem be made available as soon as possible after receiving a disconnect command.

interpret the disconnection as an error instead of a valid disconnect.

The AT command is S-Register S85=n, where n is 0 for Disable and 1 for Enable.

Line Crnt DiscEnab(>8msec) Nxt Enab(>8msec) Enab(>90msec) Disable

This configuration option does not appear on Models 3910-A1-401 and 3911-B1-001.

Line Current Disconnect. Determines the modem’s response to short interruptions of line current. The loss of line current is one method of disconnecting a call.

Enable > 8-millisecond

Disconnects the modems if line current is disrupted for more than 8 milliseconds.

Enable > 90-millisecond

Disconnects the modems if line current is disrupted for more than 90-milliseconds. Use this setting if the modem constantly disconnects when set to Enab(>8msec).

Ignores any disruptions in line current such as call waiting.

The AT command is S-Register S65=n, where n is 0 for Enable (>8 msec), 1 for Enable (>90 msec), and 2 for Disable.

Long Space DiscEnable Nxt Enable Disable

Long Space Disconnect. Determines the modem’s response to a continuous spacing condition sent from the remote modem before it goes on-hook. Issuing a long space is one method of disconnecting a call.

Modem disconnects if it receives a continuous space from the DTE. For modulations lower than 4800 bps, the modem’s transmitter will transmit 4 seconds of long space upon a disconnect.

Modem does not disconnect if it receives a continuous space from the DTE. Modem will not transmit a long space disconnect.

The AT command for Disable is Y0. The AT command for Enable is Y1.

Show 7 more labels / short text on this page
DCP Configuration · Table 4-3 · Disable · Enable · Disable · Enable · Disable
Page 131 of the Paradyne 3910 user manual — DCP Configuration
Page 131 · click to enlarge
Page 131

(4 of 5) Line Dialer Configuration Options

No Carrier Disc2sec Nxt 2sec Disable 5sec 10sec 20sec

No Carrier Disconnect. If the modem no longer receives carrier from the remote modem, it disconnects the call. This configuration option determines how long carrier is OFF before the modem disconnects. Loss of carrier is one method of disconnecting a call.

2, 5, 10, 20 sec

Modem disconnects if carrier turns OFF for more than 2 seconds, 5 seconds, 10 seconds, or 20 seconds.

Modem does not disconnect if carrier turns OFF.

The AT command is S-Register S10=n, where n is 255 for Disable or 0 to 254 in 0.1 second increments for Enable.

No Data DiscDisable Nxt Disable 10min 30min 60min

No Data Disconnect. Forces the modem to disconnect if no data is transmitted and received within a specified amount of time.

Modem remains connected despite the lack of data flow.

10, 30, 60 min

Modem disconnects if data is not received and transmitted within 10-minute, 30-minute, or 60-minute intervals.

The AT command for Enable is \Tn, where n is from 1 minute to 255 minutes. The AT command for Disable is \T0.

Auto Make BusyDisable Nxt Disable Enable

This option is only valid with the Model 3911 and does not appear on the Model 3910’s LCD.

Automatic Make Busy. Forces the modem to go off-hook under the following conditions: if a local analog loopback is performed, a self-test is performed, or if the modem is switched to the service line.

Branch Exchange (PBX). The Make Busy Network Interface Module (NIM) must be installed on the COMSPHERE 3000 Series Carrier. Refer to the COMSPHERE 3000 Series Carrier, Installation Manual.

The AT command is S-Register S40=n, where n is 0 for Disable and 1 for Enable.

Table 4-3 · Disable · Disable

Page 132 of the Paradyne 3910 user manual — DCP Configuration
Page 132 · click to enlarge
Page 132

(5 of 5) Line Dialer Configuration Options

MakeBusyVia DTRDisable End Disable Enable

Make Busy Via DTR. Determines if the modem goes off-hook when DTR is OFF. Enable this setting if the DTE normally keeps DTR ON and turns DTR OFF when the DTE cannot accept a call.

Branch Exchange (PBX). For 3911 modems, the Make Busy Network Interface Modules (NIMs) must be installed on the COMSPHERE 3000 Series Carrier. Refer to the COMSPHERE 3000 Series Carrier, Installation Manual.

The AT command is S-Register S69=n, where n is 0 for Disable and 1 for Enable.

DCP Configuration · Table 4-3

Page 133 of the Paradyne 3910 user manual — 1200/75(V23), 75/1200(V23), 600/75(V23), 75/600(V23)
Page 133 · click to enlarge
Page 133

Dial Line

The Dial Line configuration options are used to configure the modem for operation over dial lines.

Table 4-4 shows each Dial Line configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.

(1 of 3) Dial Line Configuration Options

Dial Line Rate: 19200(V32t) Nxt 19200(V32t) 16800(V32t) 14400(V32b) 12000(V32b) 9600(V32b) 7200(V32b) 4800(V32b) 2400(V22bis) 1200(V22) 1200(212A) 0-300(V21) 0-300(103J) 1200/75(V23) 75/1200(V23) 600/75(V23) 75/600(V23)

Dial Line Rate. This configuration option determines the modem’s data rate and modulation scheme for operation on dial lines. Online changes do not take effect until a disconnect occurs.

19200(V32t), 16800(V32t), 14400(V32b), 12000(V32b), 9600(V32b), 7200(V32b), 4800(V32b)

The modem operates using V.32 terbo, V.32bis, or V.32 modulation at the data rate selected.

2400(V22bis), 1200 (V22), 1200(212A)

Modem operates using the modulation and data rate selected.

0–300(V21), 0–300(103J)

Modem operates in full-duplex, Asynchronous mode. These data rates do not support V.42 or MNP error control.

1200/75(V23), 75/1200(V23), 600/75(V23), 75/600(V23)

The modem will run in asynchronous semi-full duplex mode at the rate chosen.

The AT command is S-Register S41=n, where n is:

1 = 14,400 (V.32bis) 6 = 2400 (V.22bis) 12 = 1200/75 (V.23) 20 = 19200 (V.32 terbo) 2 = 12,000 (V.32bis) 7 = 1200 (V.22) 13 = 75/1200 (V.23) 21 = 16800 (V.32 terbo) 3 = 9600 (V.32bis/V.32) 8 = 1200 (212A) 18 = 600/75 (V.23) 4 = 7200 (V.32bis) 10 = 0-300 (V.21) 19 = 75/600 (V.23) 5 = 4800 (V.32bis/V.32) 11 = 0-300 (103J)

Table 4-4

Page 134 of the Paradyne 3910 user manual — DCP Configuration
Page 134 · click to enlarge
Page 134

(2 of 3) Dial Line Configuration Options

V32bis AutomodeEnable Nxt Enable Disable System 85

This configuration option only appears when Dial Line Rate is configured for V.32 terbo, V.32bis, or V.32 data rate.

V.32bis Automode. The modem automatically adapts to the modulation scheme and line rate of the remote modem. However, the maximum data rate the modem uses is determined by the Dial Line Rate configuration option.

Enables the full automode function with special provisions which are needed to work reliably in a System 85 or similar PBX modem pool.

excluded from the Automoding sequence. Instead, the modem uses the Bell 103J protocol for 0–300 bps operation.

The AT command is S-Register S78=n, where n is 0 for Enable, 1 for Disable, and 2 for System 85.

V32bis AutorateEnable Nxt Enable Disable StartAt48 StartAt96

This configuration option only appears when Dial Line Rate is configured for V.32 terbo, V.32bis, or V.32 data rate.

V.32bis Autorate. Once connected, the modem automatically lowers the line rate if line conditions become impaired. When line conditions improve, the modem automatically shifts up to the highest data rate the line can support. This autorating only occurs between 19,200 bps and 4800 bps during V.32/V.32bis/V.32 terbo connections.

Start at 48 and Start at 96

Set the maximum connect rate for V.32/V.32bis/V.32 terbo connections.

The AT command is S-Register S76=n, where n is 0 for Enable, 1 for Disable, 2 for Start at 48, and 3 for Start at 96.

V32bis OverrideDisable Nxt Disable 2400 1200

This configuration option is ignored unless Dial Line Rate is 4800(V32b).

V.32bis Override. Activates the Paradyne Point-to-Point Diagnostic 2400 bps or 1200 bps modulation. Allows the modem to use a non-standard, point-to-point modulation capable of secondary channel diagnostics while running at 2400 bps or 1200 bps.

Dial TX Level: The factory default setting is country dependent. It is Permissv(–9) in North America Nxt Permissv(–9) –10 –11 –12 –13 –14 –15 –16 –17 –18 –19 –20 –21 –22 –23 –24 –25 –26 –27 –28 –29 –30 –31 –32

Dial Transmit Level. Selects the modem’s transmit power level over dial lines. The transmit output level can be selected in 1 dBm decrements from –9 dBm to –32 dBm.

This configuration option is locked in other countries (the user cannot change the level).

The AT command is &In, where n is from 10 to 32 corresponding to –10 dBm to –32 dBm.

DCP Configuration · Table 4-4 · System 85

Page 135 of the Paradyne 3910 user manual — DCP Configuration
Page 135 · click to enlarge
Page 135

(3 of 3) Dial Line Configuration Options

V22b Guard ToneDisable Nxt Disable 550Hz 1800Hz

This configuration option only appears when Dial Line Rate is configured for V.22bis or V.22 data rate, or when V.32bis Automode is configured for Enable.

V.22bis Guard Tone. Determines whether the V.22bis guard tone is disabled, set to 550 Hz, or set to 1800 Hz.

No guard tone.

550 Hz or 1800 Hz

When the modem is in Answer mode, it transmits the guard tone at this frequency.

The AT command for Disable is &G0. The AT command for 550 Hz is &G1. The AT command for 1800 Hz is &G2.

V32bis TrainLong End Long Short

This configuration option only appears when Dial Line Rate is configured for V.32 terbo, V.32bis, or V.32 data rate.

V.32bis Train. Controls V.32 terbo/V.32bis/V.32 train time. Determines whether minimum or maximum time durations are used during the V.32 terbo/V.32bis/V.32 handshaking sequence for both dial and 4-wire/2-wire leased-line applications.

Selects long train. Use this setting whenever far-end frequency offset (phase roll) may be encountered. This is usually only required when transmitting over satellite links.

Allows the modem to train-up faster when using V.32 terbo/V.32bis/V.32 modulation.

The AT command is S-Register S43=n, where n is 0 for Long and 1 for Short.

Show 4 more labels / short text on this page
Table 4-4 · Disable · Long · Short
Page 136 of the Paradyne 3910 user manual — Leased Line
Page 136 · click to enlarge
Page 136

Leased Line

The Leased Line configuration options only appear when the Sync Leased factory preset template is selected. They are used to configure the modem for operation over leased lines.

Table 4-5 shows each Leased Line configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.

(1 of 6) Leased Line Configuration Options

Leased Mode4WLL-Ans Nxt 4WLL-Ans 4WLL-Orig 2WLL-Orig 2WLL-Ans

Leased Mode. Sets the modem for either 2-wire or 4-wire operation in Answer mode (receiving a call) or 2-wire or 4-wire operation in Originate (initiating a call) mode.

mode and the other set to Answer mode.

For Sync Leased Answer Mode, Async Leased Answer Mode and Trellis Multipoint Tributary Mode, 4-wire Answer is the factory default.

For Sync Leased Originate Mode, Async Leased Originate Mode and Trellis Multipoint Control Mode, 4-wire Originate is the factory default.

The AT command for Disable is &L0. The AT command for 2-wire Originate is &L1. The AT command for 4-wire Originate is &L2. The AT command for 2-wire Answer is &L3. The AT command for 4-wire Answer is &L4.

DCP Configuration · Table 4-5

Page 137 of the Paradyne 3910 user manual — 9600(V29), 7200(V29), 4800(V29)
Page 137 · click to enlarge
Page 137

(2 of 6) Leased Line Configuration Options

LeasedLine Rate: 19200(V32t) Nxt 19200(V32t) 16800(V32t) 14400(V32b) 12000(V32b) 9600(V32b) 7200(V32b) 4800(V32b) 19200(TMp) 14400(TMp) 9600(TMp) 7200(TMp) 4800(TMp) 2400(TMp) 2400(V22bis) 14400(V33) 12000(V33) 9600(V29) 7200(V29) 4800(V29) 4800(V27bis) 2400(V27bis)

Leased-Line Rate. Determines the modem’s data rate and modulation scheme for operation on leased lines.

19200(V32t), 16800(V32t), 14400(V32b), 12000(V32b), 9600(V32b), 7200(V32b), 4800(V32b)

The modem operates using V.32bis or V.32 terbo modulation at the data rate selected. These modulation schemes are available on 2-wire or 4-wire leased lines.

19200(TMp), 14400(TMp), 9600(TMp), 7200(TMp), 4800(TMp), 2400(TMp)

The modem operates in Trellis Multipoint mode at the data rate selected. These modulation schemes are available on 4-wire leased lines. The 19200(TMp) modulation does not appear on tributary modems.

inbound link may be configured for 14.4 kbps while another link experiencing line impairments may be configured for 9.6 kbps. The following control/tributary rate combinations are allowed: control at 19.2 kbps, tributaries at 14.4 or 9.6 kbps; control at 14.4 kbps, tributaries at 14.4 or 9.6 kbps; control at 9.6 kbps, tributaries at 9.6 or 7.2 kbps; control at 7.2 kbps, tributaries at 7.2 or 4.8 kbps; control at 4.8 kbps, tributaries at 4.8 or 2.4 kbps; control at 2.4 kbps, tributaries at 2.4 kbps. Tributary rates will never exceed control rates. If tributary and control rates are equal, reducing the control rate automatically reduces the tributary rate.

This modulation scheme is available on 2-wire and 4-wire leased lines.

14400(V33), 12000(V33)

These modulation schemes are only available on 4-wire leased lines.

9600(V29), 7200(V29), 4800(V29)

These modulation schemes are only available on 4-wire leased lines.

This modulation scheme is available on 2-wire (half-duplex) and 4-wire leased lines.

another leased-line modulation (V.33, V.29, or V.22bis). See Err Contrl Mode configuration option for more about Direct mode. On leased lines, V.42 error control and Buffer mode are only supported by V.32bis. An error occurs if the modem is not in Direct mode when the modulation is changed from V.32bis.

The AT command is S-Register S44=n, where n is:

1 = 14,400 (V.32bis) 12 = 12,000 (V.33) 19 = 16,800 (V.32 terbo) 2 = 12,000 (V.32bis) 13 = 9600 (V.29) 20 = 19,200 (TMp) 3 = 9600 (V.32bis) 14 = 7200 (V.29) 21 = 14,400 (TMp) 4 = 7200 (V.32bis) 15 = 4800 (V.29) 22 = 9600 (TMp) 5 = 4800 (V.32bis) 16 = 4800 (V.27bis) 23 = 7200 (TMp) 6 = 2400 (V.22bis) 17 = 2400 (V.27bis) 24 = 4800 (TMp) 11 = 14,400 (V.33) 18 = 19,200 (V.32 terbo) 25 = 2400 (TMp)

Table 4-5 · 2400(V22bis) · 4800(V27bis), 2400(V27bis)

Page 138 of the Paradyne 3910 user manual — DCP Configuration
Page 138 · click to enlarge
Page 138

(3 of 6) Leased Line Configuration Options

V32bis AutorateEnable Nxt Enable Disable

This configuration option only appears when Leased Line Rate is configured for V.32 terbo or V.32bis data rate.

V.32bis Autorate. Once connected, the modem automatically lowers the line rate if line conditions become impaired. When line conditions improve, the modem automatically shifts up to the highest data rate the line can support. This autorating only occurs between 19,200 bps and 4800 bps during V.32/V.32bis/V.32 terbo connections.

The AT command is S-Register S82=n, where n is 0 for Enable and 1 for Disable.

V32bis OverrideDisable Nxt Disable 2400 1200

This configuration option is ignored unless Leased-Line Rate is 4800(V32b).

V.32bis Override. Activates the Paradyne Point-to-Point Diagnostic 1200 bps or 2400 bps modulation. Allows the modem to use a non-standard, point-to-point modulation capable of secondary channel diagnostics while running at 1200 bps or 2400 bps.

Leased Tx Level: The factory default setting is country dependent. It is 0 dBm in North America Nxt 0 –1 –2 –3 –4 –5 –6 –7 –8 –9 –10 –11 –12 –13 –14 –15

Leased Transmit Level. Selects the modem’s transmit power level over leased lines. The transmit output level can be selected in 1 dBm decrements from 0 dBm to –15 dBm.

The AT command is S-Register S45=n, where n is from 0 to 15 corresponding to 0 dBm to –15 dBm.

Auto Dial BackDisable Nxt Disable Enable FastBackup

This configuration option is not available if the LeaseLine Rate is configured for TMp and the NetworkPosition is configured for Control.

Automatic Dial Backup. Allows the modem to dial the number stored in directory location 1 to restore communications with the remote modem when the leased lines fail.

remote modem. The answering modem must have its Auto-Answer Ring Number configuration option enabled. Refer to the Line Dialer configuration option group for information regarding Auto-Answer.

maximum of 10 call attempts, with a 2-minute delay between calls. This function can be reset with a completed manual dial backup, a power cycle, or using NMS.

Only used in special applications requiring a shortened delay time from the failure of the leased lines to the initiation of the automatic dial backup.

The AT command is S-Register S46=n, where n is 0 for Disable, 1 for Enable, and 2 for FastBackup.

DCP Configuration · Table 4-5 · Fast Backup

Page 139 of the Paradyne 3910 user manual — DCP Configuration
Page 139 · click to enlarge
Page 139

(4 of 6) Leased Line Configuration Options

AutoDialStandby: Disable Nxt Disable 15min 1hr 4hr Test(2min) Adv 15min Adv 30min Adv 1 hr TestAdv2min

This configuration option is not available if the LeaseLine Rate is configured for TMp and the NetworkPosition is configured for Control.

Automatic Dial Standby. Permits a modem operating on dial lines (regardless of the method of dialing origination) to check the quality of the leased lines periodically and, if they are good, to disconnect from the dial lines and resume operations on the leased lines. The time interval that the modem uses to check the quality of the leased lines is determined by the configuration option. These intervals are 15 minutes, 1 hour, and 4 hours. The Test(2min) and TestAdv2min selections are for testing purposes only. The Adv 15min, Adv 30min, and Adv 1 hr selections cause the modem to evaluate the leased lines continuously in a manner which is non-disruptive to the dial-line communication.

The AT command is S-Register S47=n, where n is 0 for Disable, 1 for 15min, 2 for 1hr, 3 for 4hrs, 4 for Test(2min), 5 for Adv 15min, 6 for Adv 30min, 7 for Adv 1 hr, and 8 for TestAdv2min.

SpecialStandbyDisable Nxt Disable Enable

This configuration option is only available if Automatic Dial Standby is configured for 15min, 1hr, 4hr or Test(2min) and Leased mode is configured for Originate mode, or if Automatic Dial Standby is configured for Adv15min, Adv30min, Adv1hr or TestAdv(2min).

Special Standby. Used to support Automatic Dial Standby configurations when a third modem is used for the dial backup. When the leased line is restored, the Special Standby configuration allows the leased-line modems to return service to the original point-to-point modems.

Standby configuration option allows the originate modem to test the lease connection in one direction before interrupting primary data on the dial lines.

Test(2min)), the Special Standby configuration option allows a non-interruptive algorithm to test the original point-to-point lease connection in both directions before interrupting primary data on the dial lines.

The AT command is S-Register S98=n, where n is 0 for Disable and 1 for Enable.

Dial StandbyTime10min Nxt 10min 5min 1min

Dial Standby Time. Selects the amount of time that a dial circuit is held after returning to the leased lines.

CarrierOn Level–43dbm Nxt –43dbm –26dbm

Carrier On Level. Controls the carrier detection threshold for leased lines. When the power level of the receive carrier signal drops 2 dBm below this level (either –26 dBm or –43 dBm), LSD turns OFF. When the carrier signal is greater than this level, LSD turns ON.

For TMp Control, –26dbm is the factory default.

The AT command is S-Register S48=n, where n is 0 for –43 dBm and 1 for –26 dBm.

V27bis TrainShort Nxt Short Long

This configuration option is only available if Leased-Line Rate is configured for V27bis.

Table 4-5

Page 140 of the Paradyne 3910 user manual — DCP Configuration
Page 140 · click to enlarge
Page 140

(5 of 6) Leased Line Configuration Options

V.27bis Train. Controls the train time for V.27bis operation.

The AT command is S-Register S70=n, where n is 0 for Short and 1 for Long.

V29 TrainOnDataDisable Nxt Disable Enable

This configuration option is only available if Leased-Line Rate is configured for V29.

V.29 Train On Data. When enabled, the modem receiver can train based upon the incoming data or a training sequence from the distant modem. This function is necessary for a remote (tributary) modem in a V.29 multipoint network and is recommended for a control modem as well.

The AT command is S-Register S92=n, where n is 0 for Disable and 1 for Enable.

V29 RetrainEnable Nxt Disable Enable

This configuration option is only available if Leased-Line Rate is configured for V29.

V.29 Retrain. When enabled, the modem transmits a training sequence whenever it receives one. This configuration option should normally be disabled for control modems.

The AT command is S-Register S93=n, where n is 0 for Enable and 1 for Disable.

V29 Link ConfigPointToPoint Nxt PointToPoint Multipoint

This configuration option is only available if Leased-Line Rate is configured for V29.

V.29 Link Configuration. Selects point-to-point or multipoint operation.

The AT command is S-Register S94=n, where n is 0 for PointToPoint and 1 for Multipoint.

TMp Train Time50 Nxt 50 10 20 100 200 300

This configuration option is only available if Leased-Line Rate is configured for TMp.

Trellis Multipoint (TMp) Train Time. Defines the length of time energy is sent from the tributary modem to the control modem. More severe line conditions require longer time selections.

The AT command is S-Register S95=n, where n is 0 for 10 milliseconds, 1 for 20 milliseconds, 2 for 50 milliseconds, 3 for 100 milliseconds, 4 for 200 milliseconds, and 5 for 300 milliseconds.

TMp TxPreemphasisEnable Nxt Enable Disable

This configuration option is only available if Leased-Line Rate is configured for TMp.

Trellis Multipoint (TMp) Transmit Preemphasis. Provides amplification for frequencies above the carrier frequency to compensate for high frequency line attenuation.

The AT command is S-Register S96=n, where n is 0 for Enable and 1 for Disable.

Lease_LookbackDisable Nxt Disable Enable

Lease Lookback. While operating on backup lines, this configuration option allows the modem to test the primary 4-wire leased lines for connectivity by detecting line energy across the normal line bandwidth. This test of the primary lines will not interrupt the data flow on the backup lines. The configuration option settings must be the same at both ends.

DCP Configuration · Table 4-5

Page 141 of the Paradyne 3910 user manual — V.42/MNP/Buffer
Page 141 · click to enlarge
Page 141

(6 of 6) Leased Line Configuration Options

Dual_Leased_LnDisable Nxt Disable Enable

This configuration option is only available when the Dual Leased Line device option is installed.

Dual Leased Line. Allows the 2-wire backup facility to function as a 2-wire leased-line facility. When this configuration option is disabled, the backup facility is a 2-wire dial line.

ring indication, and call progression functions, you control the backup function as if it were a normal dial backup.

option can be enabled.

BackupLineCheckDisable Nxt Disable Enable

This configuration option is only available when the Dual Leased Line device option is installed.

BackupLine Check. Tests the backup circuit for availability while the modem is operating on the primary leased lines. The test involves detecting line energy across the normal bandwidth. This test of the backup lines will not interrupt the data flow on the primary lines. The configuration option settings must be the same at both ends.

than the modem connected to the primary leased-line, enabling this configuration option can cause problems.

V.42/MNP/Buffer

V.42/MNP/Buffer configuration options determine the type of error correction and flow control used by the modems and attached DTEs.

Some choices within this group may not appear depending upon how previous configuration options have been selected. If the Async/Sync Mode configuration option is set for synchronous operation (refer to the DTE Interface configuration options group), then the V.42/MNP/Buffer group does not appear on the LCD. Any changes made to configuration options within this group only take effect after a disconnect.

Table 4-6 shows each V.42/MNP/Buffer configuration option as it appears on the LCD, with the Async Dial factory default setting shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.

Table 4-5

Page 142 of the Paradyne 3910 user manual — DCP Configuration
Page 142 · click to enlarge
Page 142

(1 of 8) V.42/MNP/Buffer Configuration Options

Err Contrl ModeV42/MNPorBfr Nxt V42/MNPorBfr V42/MNPorDsc MNP_or_Buffr MNP_or_Disc BufferMode DirectMode LAPM_or_Disc LAPM_or_Bufr

This configuration option is only available if Async/Sync Mode is configured for Async.

Error Control Mode. Determines the type of error control used by the modem. In most cases, V42/MNPorBfr is the best choice. If V.42bis and MNP are enabled, then the modem uses the following priority for error control negotiation: V.42bis, V.42, MNP 5 and below. Online changes do not take effect until a disconnect occurs.

V.42/MNP or Buffer

Modem attempts to connect in V.42 Error Control mode using V.42 Link Access Procedure for Modems (LAPM) protocol. If this fails, the modem attempts to connect in MNP mode. If this fails, the modem connects in Buffer mode and continues operation. This is also known as V42/MNP Autoreliable Mode.

V.42/MNP or Disconnect

Modem attempts to connect in V.42 Error Control mode using V.42 LAPM protocol. If this fails, the modem attempts to connect in MNP mode. If this fails, the modem disconnects. This is also known as Reliable mode.

MNP or Buffer

Modem attempts to connect in MNP mode. If this fails, the modem connects in Buffer mode. This is also known as MNP Autoreliable Mode.

MNP or Disconnect

Modem attempts to connect in MNP mode. If this fails, the modem disconnects. This is also known as Reliable mode.

Modem does not use error control and allows the DTE rate to differ from the communications line rate. This mode should only be used if the DTE provides its own error control or if errors in data can be tolerated. This setting is also known as Normal mode and is valid even if the remote modem is set to Direct mode.

Modem connects at a data rate equal to or less than the initial DTE interface rate. (The modem never connects at a data rate greater than the initial DTE rate.) If the modem connects at a data rate lower than the DTE rate, the DTE must then adjust its data rate to equal the modem rate. Ultimately, the modem speed and DTE speed must be the same. Direct mode does not support error control or data buffering.

LAPM or Disconnect

Modem attempts to connect in LAPM mode. If this fails, the modem disconnects.

LAPM or Buffer

Modem attempts to connect in LAPM mode. If this fails, the modem connects in Buffer mode.

V.42 error control or Buffer mode are enabled with V.32bis or TMp on leased lines.

Show 4 more labels / short text on this page
DCP Configuration · Table 4-6 · Buffer Mode · Direct Mode
Page 143 of the Paradyne 3910 user manual — DCP Configuration
Page 143 · click to enlarge
Page 143

(2 of 8) V.42/MNP/Buffer Configuration Options

Err Contrl Mode (Continued) Nxt V42/MNPorBfr V42/MNPorDsc MNP_or_Buffr MNP_or_Disc BufferMode DirectMode LAPM_or_Disc LAPM_or_Bufr

The AT command for Buffer Mode is \N0. The AT command for Direct Mode is \N1. The AT command for MNP or Disconnect is \N2. The AT command for MNP or Buffer is \N3. The AT command for V42/MNP or Disconnect is \N4. The AT command for V42/MNP or Buffer is \N5. The AT command for LAPM or Disconnect is \N6. The AT command for LAPM or Buffer is \N7.

V42bis CompressEnable Nxt Enable Disable

This configuration option is only available if Async/Sync Mode is configured for Async, and Error Control Mode is configured for V42/MNPorBfr or V42/MNPorDsc.

V.42bis Data Compression. Enables or disables V.42bis data compression.

Data compression operates in both the transmit and receive directions. This is the recommended setting for all applications.

V.42bis data compression is disabled. This is rarely needed because V.42bis data compression does not cause data expansion for compressed data.

The AT command for Disable is ″H0. The AT command for Enable is ″H1, ″H2, or ″H3.

MNP5 CompressEnable Nxt Enable Disable

This configuration option is only available if Async/Sync Mode is configured for Async, and Error Control Mode is configured for V42/MNPorBfr, V42/MNPorDsc, MNP_or_Buffr, or MNP_or_Disc.

MNP5 Compression. Determines if the modem uses MNP Class 5 data compression. It can be set independently of V.42bis data compression. Online changes do not take effect until a disconnect occurs.

The AT command for Disable is %C0. The AT command for Enable is %C1.

Table 4-6 · Enable · Disable

Page 144 of the Paradyne 3910 user manual — DCP Configuration
Page 144 · click to enlarge
Page 144

(3 of 8) V.42/MNP/Buffer Configuration Options

EC Negotiat BfrDisable Nxt Disable Enable Disab&Switch

This configuration option is only available if Async/Sync Mode is configured for Async, and Error Control Mode is configured for V42/MNPorBfr, MNP_or_Buffr, or LAPM_or_Bufr.

Error Control Negotiate Buffer. Determines if the answering modem buffers the data that it received from the remote modem during an interval in which the modem attempts to establish a connection using error control. Online changes do not take effect until a disconnect occurs.

Data is not buffered during the link negotiating (handshaking) sequence.

Data is buffered while the link is being established. Initialization data is not passed on the DTE during the handshaking sequence.

Disable and Switch

Data is not buffered during the handshaking sequence. However, when the modem receives an error control fallback character, it switches to Buffer mode. (Refer to the EC Fallback Char configuration option.)

The AT command for Disable is \C0. The AT command for Enable is \C1. The AT command for Disab&Switch is \C2.

EC Fallbck Char013 ASCI Nxt 013 ASCI

This configuration option is only available if Async/Sync Mode is configured for Async, and EC Negotiate Buffer is not configured for Disable.

Error Control Fallback Character. This configuration option allows you to enter the ASCII value of the error control fallback character. This provides the remote modem with the ability to end the error control link negotiating (handshaking) sequence by sending this character. The modems will connect in Buffer mode (no error control). Online changes do not take effect until a disconnect occurs. When the modem receives this fallback character it switches to Buffer mode and transmits an EC fallback character to the DTE. When comparing incoming characters for a match against the EC fallback character, the modem ignores parity.

The AT command is %An, where n is a value from 0 to 127.

Show 4 more labels / short text on this page
DCP Configuration · Table 4-6 · Disable · Enable
Page 145 of the Paradyne 3910 user manual — XON/XOFF
Page 145 · click to enlarge
Page 145

(4 of 8) V.42/MNP/Buffer Configuration Options

Flw Cntl of DTECTS_to_DTE Nxt CTS_to_DTE Disable XON/XOFF

This configuration option is only available if Async/Sync Mode is configured for Async, and Error Control Mode is not configured for DirectMode.

Flow Control of DTE. Determines how the modem controls the flow of data from the DTE.

CTS to DTE

Method of flow control in which the modem raises and lowers its CTS interface lead to indicate when the DTE should start and stop sending data.

The modem cannot control the flow of data from the DTE.

XON/XOFF

Method of flow control in which the modem sends XON and XOFF characters to the DTE to start and stop the flow of data.

The AT commands for Disable are \Q0, \Q5, and \Q6. The AT commands for XON/XOFF are \Q1 and\Q4. The AT commands for CTS to DTE are \Q2 and \Q3.

Flw Cntl of MdmRTS_to_Mdm Nxt RTS_to_Mdm Disable XON/XOFF

This configuration option is only available if Async/Sync Mode is configured for Async, and Error Control Mode is not configured for DirectMode.

Flow Control of Modem. Determines how the DTE controls the flow of data from the modem.

RTS to Modem

Method of flow control in which the modem respectively starts and stops data transmission based upon the ON and OFF state of the DTE’s RTS signal.

The DTE cannot control the flow of data from the modem.

XON/XOFF

Method of flow control in which the modem starts and stops data flow based upon XON and XOFF characters received from the DTE.

The AT commands for Disable are \Q0, \Q2, and \Q4. The AT commands for XON/XOFF are \Q1 and\Q5. The AT commands for RTS to Modem are \Q3 and \Q6.

Table 4-6 · Disable · Disable

Page 146 of the Paradyne 3910 user manual — DCP Configuration
Page 146 · click to enlarge
Page 146

(5 of 8) V.42/MNP/Buffer Configuration Options

XON/XOFF PsthruDisable Nxt Disable Enable

This configuration option is only available if Async/Sync Mode is configured for Async, and Flow Control of Modem is configured for XON/XOFF.

XON/XOFF Passthrough. Considers an XON/XOFF character as data and passes it on to the remote modem. In this case, the DTE at one end of the communications link can send flow control characters to the other DTE. This is also known as DTE to DTE flow control.

Flow control characters are processed but are not passed on to the remote modem.

Flow control characters are processed and passed on to the remote modem.

The AT command for Disable is \X0. The AT command for Enable is \X1.

Mdm/Mdm FlowCtlDisable Nxt Disable Enable

This configuration option is only available if Async/Sync Mode is configured for Async, and Error Control Mode is configured for V42/MNPorBfr, MNP_or_Buffr, LAPM_or_Bufr, or BufferMode.

Modem-to-Modem Flow Control. If a modem’s buffers begin to fill due to data it is receiving from the remote modem, but is not passing on to the DTE, it can issue XON/XOFF flow control characters to the remote modem. This only applies if Buffer (nonerror control) mode is selected. If Error Control mode is enabled, flow control between the modems will happen automatically, regardless of the setting of this option.

Modem does not respond to XON and XOFF characters received over the VF line. Also, the modem will not transmit an XOFF character to the remote end if its receive buffers are full.

Modem stops transmitting data to the remote modem if it receives an XOFF character over the VF line. An XON character will enable data transmission. Also, the modem will transmit an XOFF character to the remote end if its receive buffers are full. Select this setting if the DTE rate is less than the VF line rate or if the DTE must frequently stop the flow of data to process it.

The AT Command for Disable is \G0. The AT Command for Enable is \G1.

Show 6 more labels / short text on this page
DCP Configuration · Table 4-6 · Disable · Enable · Disable · Enable
Page 147 of the Paradyne 3910 user manual — DCP Configuration
Page 147 · click to enlarge
Page 147

(6 of 8) V.42/MNP/Buffer Configuration Options

Break Buffr CtlKeep_Data Nxt Keep_Data Discard_Data

This configuration option is only available if Async/Sync Mode is configured for Async, and Error Control Mode is not configured for DirectMode.

Break Buffer Control. Determines if data stored in the modem’s buffer is saved or discarded when the DTE issues a break sequence.

Keep Data (Nondestructive mode)

Saves the data in the buffer in both the local and remote modems.

Discard Data (Destructive mode)

Empties the data buffer. Only buffers in the same direction of travel as the break are discarded.

Dialer configuration options group) is enabled.

The AT commands for Discard Data are \K0 and \K1. The AT commands for Keep Data are \K2, \K3, \K4, and \K5.

Send Break CntlData_First End Data_First Break_First

This configuration option is only available if Async/Sync Mode is configured for Async, and Error Control Mode is not configured for DirectMode.

Send Break Control. Determines what is sent from the modem first, data or break if a break sequence is sent from the DTE.

Data First (Nonexpedited)

A break is treated as a data character and is sent in the order it was received. This is also known as Nonexpedited mode.

Break First (Expedited)

A break is sent before the data currently in the buffer. This is also known as Expedited mode.

Dialer configuration options group) is enabled.

The AT commands for Break First are \K0, \K1, \K2, and \K3. The AT commands for Data First are \K4 and \K5.

Table 4-6

Page 148 of the Paradyne 3910 user manual — DCP Configuration
Page 148 · click to enlarge
Page 148

(7 of 8) V.42/MNP/Buffer Configuration Options

BuffrDiscDelay10sec Nxt 10sec Disable 60sec

This configuration option is only available if Async/Sync Mode is configured for Async, and Error Control Mode is not configured for DirectMode.

Buffer Disconnect Delay. Determines how long the modem continues to transmit data stored in its buffers when the modem is commanded to disconnect by a locally attached DTE. This also applies to the modem’s receiving buffers when it is commanded to disconnect from a remote modem or DTE.

Modem disconnects immediately without attempting to send data stored in its buffers.

10, 60 sec

Maximum amount of time the modem tries to empty its buffers before disconnecting. In both cases (10 sec and 60 sec), the modem disconnects much sooner if it can empty its buffers.

Mode.

The AT command is S-Register S49=n, where n is 0 for Disable and any value from 1 to 255 in 1 second increments.

Max Frame Size256 Nxt 256 192 128 64 32 16

This configuration option is only available if Async/Sync Mode is configured for Async, and Error Control Mode is not configured for BufferMode or DirectMode.

Maximum Frame Size. Sets the maximum frame size for V.42 and MNP. For V.42 operation, 128 is the maximum value. Any value which exceeds this will automatically default to 128 for V.42. For MNP operation, 64 is the minimum value. Any value less than that will automatically default to 64. For cellular applications, at least one of the sides should be set to a low value. A setting of 32 is recommended. Only one modem needs this setting; both modems will automatically default to the greatest common value.

The AT Command for 256 is \A3. The AT Command for 192 is \A2. The AT Command for 128 is \A1. The AT Command for 64 is \A0. The AT Command for 32 is \A4. The AT Command for 16 is \A5.

CellularEnhanceDisable Nxt Disable Enable

This configuration option is only available if Async/Sync Mode is configured for Async, and Error Control Mode is configured for V42/MNPorBfr, V42/MNPorDsc, LAPM_or_Disc, or LAPM_or_Bufr.

Cellular Enhancement. When enabled, the modem uses non-standard techniques to enhance V.42 operation for cellular applications. It is still compatible, however, with modems which do not have the cellular enhancement implemented or enabled.

The AT command is S-Register S91=n, where n is 0 for Disable and 1 for Enable.

DCP Configuration · Table 4-6 · Disable

Page 149 of the Paradyne 3910 user manual — Test
Page 149 · click to enlarge
Page 149

(8 of 8) V.42/MNP/Buffer Configuration Options

RdcdAsyncBufSizDisable End Disable Enable

This configuration option is only available if Async/Sync Mode is configured for Async, and Error Control Mode is configured for BufferMode, V42MNPorBuf, MNP_or_Buffr, and LAPM_or_Bufr mode.

Reduced Asynchronous Buffer Size. When enabled, the modem’s buffer size is limited to a maximum of 20 characters.

The AT command is S-Register S97=n, where n is 0 for Disable and 1 for Enable.

Test

The Test configuration options determine specifics, such as the duration of a test, for the various diagnostic tests available to the modem.

Table 4-7 shows each Test configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.

(1 of 2) Test Configuration Options

DTE RL (CT140)Disable Nxt Disable Enable

DTE Remote Loopback. Controls the use of Pin 21 of the EIA-232-D/CCITT V.24 interface by the DTE to initiate a remote loopback. An Abort command or test time-out ends this test.

This configuration option is not available if the LeasedLine Rate is configured for TMp.

The DTE forces the modem into remote loopback when the signal on Pin 21 (CCITT 140) is turned ON. Remote Loop ends when the signal is dropped.

The DTE does not initiate remote loopback in response to the signal on Pin 21.

The AT command is S-Register S51=n, where n is 0 for Disable and 1 for Enable.

DTE LL (CT141)Disable Nxt Disable Enable

DTE Local Loopback. Controls the use of Pin 18 of the EIA-232-D/CCITT V.24 interface by the DTE to initiate a local loopback. An Abort command or test time-out ends this test.

The DTE forces the modem into local loopback when the signal on Pin 18 (CCITT 141) is turned ON. Local loopback ends when the signal is dropped.

The DTE will not initiate local loopback in response to the signal on Pin 18.

The AT command is S-Register S52=n, where n is 0 for Disable and 1 for Enable.

Show 6 more labels / short text on this page
Table 4-6 · Table 4-7 · Enable · Disable · Enable · Disable
Page 150 of the Paradyne 3910 user manual — DCP Configuration
Page 150 · click to enlarge
Page 150

(2 of 2) Test Configuration Options

Test TimeoutDisable Nxt Disable 30sec 60sec 240sec

Test Time-out. Determines how long a test runs before aborting.

Allows a test to run indefinitely.

30, 60, or 240 seconds

Allows the test to run for 30 seconds, 60 seconds, or 240 seconds.

The AT command is S-Register S18=n, where n is 0 for Disable and 1 to 255 seconds.

Rcv Remote LoopEnable Nxt Enable Disable

This configuration option is not available if the LeasedLine Rate is configured for TMp.

Receive Remote Loopback Response. Determines if the modem responds to a request for a remote loopback issued from a remote modem.

The AT command for Enable is &T4. The AT command for Disable is &T5.

V54 AddressDisable Nxt Disable (Address Values)

This configuration option is not available if the LeasedLine Rate is configured for TMp.

V.54 Address. Determines which remote 391x Series modem is placed into a remote loopback test. This test can be either a remote digital loopback or local analog loopback. This type of addressing is recommended for use in extended data circuits (tail circuits).

This is used for normal point-to-point leased-line and dial networks.

01, 03, 05, 07, 09, 0B, 0D, 0F, 11, 13, 15, 17, 19, 1B, 1D, 1F, 25, 27, 2B, 2D, 2F, 33, 35, 37, 3B, 3D, 3F, 55, 57, 5B, 5F, 6F, 77, or 7F. This configuration option selects the address of a modem that is to be placed into a loopback test. This option is used for more complex networks where multiple modems, used in extended data circuits (tail circuits), can be commanded to loopback.

The AT command for Disable is S-Register S53=0. The AT command for V.54 Address is S-Register S53=n, where n is a value from 1 to 34.

V54 Device TypePeripheral End Peripheral Intermediate

This configuration option is only available if V54 Address is enabled and the LeasedLine Rate is configured for TMp.

V.54 Device Type. Identifies where the modem is physically located in the network.

The modem is located at the endpoint of the network and is not connected back-to-back with another modem.

The modem is either of the two modems connected back-to-back.

The AT command for Peripheral is S-Register S54=0. The AT command for Intermediate is S-Register S54=1.

Show 7 more labels / short text on this page
DCP Configuration · Table 4-7 · Disable · Disable · Address Values · Peripheral · Intermediate
Page 151 of the Paradyne 3910 user manual — Misc
Page 151 · click to enlarge
Page 151

Misc

The Miscellaneous configuration options determine specifics for various functions, including network management parameters and remote modem access.

Table 4-8 shows each Misc (Miscellaneous) configuration option as it appears on the LCD, with the Sync Leased factory default setting (the default value if the modem is just being installed) shown following the colon ( : ) on the first line and with all available selections listed on the second line. Following this is a description of the configuration option. Factory default settings are listed in Appendix F.

(1 of 4) Miscellaneous Configuration Options

StrapsWhenDiscNo_Change Nxt No_Change Reload

Straps When Disconnected. Determines whether or not configuration options in the Active (Saved) configuration area are reloaded to Active (Operating) when a disconnect occurs. This is useful in modem pooling applications.

Configuration options do not change if a disconnect occurs.

The Active (Operating) configuration area, which controls modem operation, is reloaded from the Active (Saved) configuration area when a disconnect occurs. This is useful in modem pooling applications where it is desirable to start the modem from a known condition after every call. This allows multiple users to issue AT commands to change the modem’s operation for their particular call.

when the following commands are issued: AT&F0, AT&F1, AT&F2, AT&F3, AT&F4, AT&F5, AT&F6, AT&F7, AT&F8, AT&W0, AT&W1, AT&W2, and AT&Zn=x.

The AT command for the Straps When Disconnected configuration option is S-Register S88=n, where n is 0 or 231 for No_Change, and 1 or 232 for Reload.

Speaker ControlOnUntilCarr Nxt OnUntilCarr Off On

Speaker Control. Determines if the speaker is OFF, ON until carrier signal is received by the modem, or ON all the time.

cycle will restore the modem to the Speaker Control and Speaker Volume configuration option settings.

The AT command for Off is M0 The AT command for On Until CD is M1. The AT command for On is M2.

Table 4-8 · No Change · Reload

Page 152 of the Paradyne 3910 user manual — DCP Configuration
Page 152 · click to enlarge
Page 152

(2 of 4) Miscellaneous Configuration Options

Speaker VolumeMedium Nxt Medium Low High

Speaker Volume. Controls the level of speaker volume.

cycle will restore the modem to the Speaker Control and Speaker Volume configuration option settings.

The AT command for Low is L0 or L1. The AT command for Medium is L2. The AT command for High is L3.

Access frm RemtEnable Nxt Enable Disable

Access from Remote. Determines if your modem’s DCP can be accessed by a remote modem via the VF line.

Allows access from a remote modem.

Does not allow access from a remote modem.

The AT command is S-Register S55=n, where n is 0 for Enable and 1 for Disable.

RemAccssPasswrd00000000 Nxt 00000000

Remote Access Password. Allows the entry of a password for establishing control of a remote modem from the DCP of a local modem. The same password must be used in both the local and remote modem.

The AT command equivalent is S-Registers S56=n, S57=x, S58=y, and S59=z, where n is the leftmost pair of digits, x is the second pair of digits, y is the third pair of digits, and z is the rightmost pair (or fourth) pair of digits. For example, if the remote access password is 12345678, then the value for S56 is 1 and 2, and the value for S59 is 7 and 8.

Dir#1_CallbackDisable Nxt Disable Enable

Directory Location 1 Callback. This configuration option controls whether or not the modem’s single number callback function is used.

Modem does not use the single number callback function.

Modem answers a call, disconnects, and dials the number stored in directory location 1.

The AT Command to Disable is S-Register S67=0. The AT Command to Enable is S-Register S67=1.

Show 6 more labels / short text on this page
DCP Configuration · Table 4-8 · Enable · Disable · Disable · Enable
Page 153 of the Paradyne 3910 user manual — DCP Configuration
Page 153 · click to enlarge
Page 153

(3 of 4) Miscellaneous Configuration Options

NMS_Call_MsgsCallCnct&Prg Nxt CallCnct&Prg Disable CallCnctOnly CallProgOnly

NMS Call Messages. Determines if the modem status and/or call summary information is sent to the NMS. The modem can itemize status, such as CallProgress messages, or it can report a summary of activity, such as Call Connect messages, to the NMS.

Call Connect & Progress

Enables both Call Connect and Call Progress information to be transmitted to the NMS.

Modem status and call summary information is not sent to the NMS.

Call Connect Only

The modem accumulates call statistics over a period of time and then transmits a summary of these statistics to the NMS. The NMS uses this data to produce utilization reports.

Call Progress Only

The modem transmits detailed modem status information to the NMS. These messages include any events that can display on the LCD.

The AT commands are S-Register S66=n where n is 0 for Call Connect & Progress, 1 for Disable, 2 for Call Connect Only, and 3 for Call Progress Only.

NetworkPositionTributary End Tributary Control

Network Position Identification. Each modem must be identified either as a control modem or a tributary modem.

For the Model 3910, Tributary is the factory default. For the Model 3911, Control is the factory default.

The AT command for Tributary is S74=0. The AT command for Control is S74=1.

NetMngmtAddress256 Nxt 256

This configuration option is not available in point-to-point tributaries.

Network Management Address. Determines the address used when accessing a modem from the NMS or when using DCP functions that require network management addresses. Within a network link, a control modem can communicate with a tributary modem by using the tributary modem’s network management address. Each tributary modem must have a different network management address.

Address values range from 001 to 256.

The AT command is S-Register S75=n, where n is a value from 0 to 255 (001 to 256).

Table 4-8 · Disable

Page 154 of the Paradyne 3910 user manual — Security
Page 154 · click to enlarge
Page 154

(4 of 4) Miscellaneous Configuration Options

Diag ConnectionModem(DC) Nxt Modem(DC) NMS(CC) Disable

This configuration option is not available if the LeaseLine Rate is configured for TMp and the NetworkPosition is configured for Tributary.

Diagnostic Connection. Allows the configuration of the serial diagnostic port of the modem to be either a diagnostic channel that is connected to another modem (DC), or a control channel that is connected to a network management device (CC).

Selects the Diagnostic Channel.

NMS

Selects the Control Channel.

Prevents messages being sent from the diagnostic port.

Link Delay (sec)0 1 Nxt 0 1 2 5 10 20 50

Link Delay Seconds: Controls the length of time (in seconds) a modem will wait for responses from the downstream devices. This configuration option is used to calculate protocol timers for polling and normal selection.

Security

The Security configuration options allow you to set the parameters that control how a dial access security password is entered. For security configuration options, refer to Chapter 6, Dial Access Security.

Show 4 more labels / short text on this page
DCP Configuration · Table 4-8 · Modem · Disable
Page 155 of the Paradyne 3910 user manual — Switching Between Data Mode and Online Command Mode
Page 155 · click to enlarge
Page 155

AT Command Set and S-Registers

Overview 5-1 Operating Modes 5-1 Switching Between Data Mode and Online Command Mode 5-1 Escape Sequence and Escape Guard Time 5-2 Command Guidelines 5-2 Result Codes 5-3 AT Command List 5-4 AT Command Format 5-4 S-Register List 5-14 S-Register Format 5-15

Overview

The AT command set provides an alternative method to the modem’s DCP for entering commands that control the operation and configuration of the 391x Series modems. This chapter discusses guidelines necessary to operate AT commands as well as listing the modifiers for all AT commands supported by the 391x Series modems. AT commands are issued from asynchronous DTEs.

Operating Modes

The 391x Series modem has two operating modes, Command mode and Data mode. Before a modem goes online (establishes a successful connection with a remote modem), it is considered to be in Command mode; an idle state where you can modify its operating parameters or issue modem commands. (Any command issued is acknowledged with a response in either words or digits known as Result Codes. Refer to Table 5-1 for a listing of result codes.)

Once the modems are online, either by answering or originating a call, they automatically switch to Data mode. Data mode is a state where any entries made from the DTE are considered data and are transmitted and received between modems. The modems remain in Data mode until the connection is broken or until they are forced into online Command mode using the escape sequence.

Switching Between Data Mode and Online Command Mode

Sometimes it is necessary to change operating parameters while the modems are online. The Escape Sequence allows you to toggle the modem between Data mode and online Command mode while maintaining a connection with the remote modem. This is accomplished using the escape sequence ( + + + ) to exit Data mode and the O command to return to Data mode.

Page 156 of the Paradyne 3910 user manual — Command Guidelines
Page 156 · click to enlarge
Page 156

Escape Sequence and Escape Guard Time

The escape sequence is only issued when the modem is online and in Data mode. The 391x Series modem uses three consecutive plus ( + ) characters as the escape sequence. (To change this value, refer to S-Register S2 discussed later in Table 5-3 in the S-Register Format section.)

To prevent the modem from interpreting an embedded + + + in data as an escape sequence, the Escape Guard Time value determines the length of the pause before and after the escape sequence is issued. The 391x Series modem uses a one-second pause as the Escape Guard Time. (To change this value, refer to S-Register S12 discussed later in Table 5-3 in the S-Register Format section.)

To enter online Command mode while in Data mode, enter the following sequence:

TYPE: + + +

Use the O command to return to Data mode from online Command mode. Enter the following command:

TYPE: ATO

PRESSEnter

Command Guidelines

Review the following guidelines before using any AT Commands.

  • The escape sequence ( + + + ) is used to enter online Command mode from Data mode.
  • The asynchronous character format for the AT command set must be one of the following:

— 8 data bits + no parity + 1 stop bit.

— 7 data bits + no parity + 2 stop bits.

— 7 data bits + parity + 1 stop bit (parity can be odd, even, mark, or space).

  • All commands (except A/ and + + + ) must begin with the characters A T and end by pressing the Enter key. The AT (or at) prefix clears the command buffer and matches the modem speed and parity to that of the DTE. Commands can be upperor lowercase, but the modem will not recognize mixed case prefixes (At or aT).
  • Commands can be entered one at a time or in strings. Strings can have up to 40 characters after the AT prefix. Y ou can use spaces, hyphens ( - ), and parentheses ( ) as fillers to make the commands easier to read; the modem ignores these fillers and they are not counted among the characters which make up the command string. Commands must be entered on one line and end with the carriage return character (Enter key).
  • Commands with the suf fix n have several options associated with them. For example, in the L n command, L1 sets the speaker volume to Low and L3 sets the speaker volume to High. If no value is entered for the n suffix, the modem assumes a zero ( 0 ) value.
  • The A/ command (without pressing the Enter key) causes the modem to repeat the last command entered.
  • Valid commands are acknowledged with numeric or word result codes (unless the result codes have been disabled using the Q1 command). T able 5-1 lists all available result codes with numeric and word equivalents.
Page 157 of the Paradyne 3910 user manual — Result Codes
Page 157 · click to enlarge
Page 157

AT Command Set and S-Registers

Result Codes

Table 5-1 lists all valid result codes for the 391x Series modem.

(1 of 2) Result Codes

0 0 OK Command executed

1 1 CONNECT Modem connected to line

2 2 RING Modem receiving a ring voltage from the VF line

3 3 NO CARRIER Modem lost carrier signal, does not detect carrier signal, or does not detect answer tone

4 4 ERROR Invalid command

5 5 CONNECT 1200* Connection at 1200 bps

6 6 NO DIALTONE* No dial tone detected

7 7 BUSY* Busy or trunk busy signal detected

8 8 NO ANSWER* No “quiet” answer (@)

10 10 CONNECT 2400* Connection at 2400 bps

11 11 CONNECT 4800* Connection at 4800 bps

12 12 CONNECT 9600* Connection at 9600 bps

13 16 CONNECT 12000* Connection at 12,000 bps

14 13 CONNECT 14400* Connection at 14,400 bps

15 14 CONNECT 19200** Connection at 19,200 bps

16 15 CONNECT 7200* Connection at 7200 bps

17 17 CONNECT 16800** Connection at 16,800 bps

19 19 CONNECT 300* Connection at 300 bps

20 10 CONNECT 2400/ EC*** Connection at 2400 bps with error control

21 11 CONNECT 4800/ EC*** Connection at 4800 bps with error control

22 12 CONNECT 4800/ EC*** Connection at 4800 bps with error control

23 16 CONNECT 12000/ EC*** Connection at 12,000 bps with error control

24 13 CONNECT 14400/ EC*** Connection at 14,400 bps with error control

25 17 CONNECT 16800/ EC** Connection at 16,800 bps with error control

* Only appears when the Extended Result Codes configuration option is enabled. ** Only appears when the Extended Result Codes configuration option is set for Use_DTE_Rate. This displays the DTE data rate instead of the line rate. *** Only appears when the Extended Result Codes configuration option is set for Add/EC. If this configuration option is set for Add/V42, MNP, then either V42b, V42, MNP5, MNP4, MNP3, MNP2, or NoEC appears.

Show 5 more labels / short text on this page
Table 5-1 · Numbers · Numbers · (2) Word Description · (1)
Page 158 of the Paradyne 3910 user manual — AT Command Format
Page 158 · click to enlarge
Page 158

(2 of 2) Result Codes

(1) Description Word Numbers

26 15 CONNECT 7200/ EC*** Connection at 7200 bps with error control

27 5 CONNECT 1200/ EC* Connection at 1200 bps with error control

28 28 CONNECT 38400** Connection at 38,400 bps

29 14 CONNECT 19200/ EC** Connection at 19,200 bps with error control

30 30 CONNECT 57600** Connection at 57,600 bps

77 77 FORBIDDEN Forbidden number

78 78 DELAYED Delayed number

* Only appears when the Extended Result Codes configuration option is enabled. ** Only appears when the Extended Result Codes configuration option is set for Use_DTE_Rate. This displays the DTE data rate instead of the line rate. *** Only appears when the Extended Result Codes configuration option is set for Add/EC. If this configuration option is set for Add/V42, MNP, then either V42b, V42, MNP5, MNP4, MNP3, MNP2, or NoEC appears.

AT Command List

AT commands are issued from an asynchronous DTE, such as a PC, and control the modem’s operation and software configuration. AT commands are only applicable when the DTE Dialer Type configuration option is set for AT. (Refer to the &Mn and &Qn commands.)

Table 5-2 lists all AT commands supported by the 391x Series modem. The first column lists the AT command. The second column defines and lists all possible values for that command. The Async Dial factory default is listed in bold. The third column lists the key sequence used to enter the equivalent DCP command. Use this to reference commands in Chapter 3 or Chapter 4 if further description is necessary.

AT Command Format

AT commands are entered in Command mode using the following format:

TYPEAT Xn

Where: X is the AT command and n is the specific value for that command.

PRESSEnter

In Table 5-2, the value for X is listed in the AT Command column and the value for n is listed in the Description column.

Table 5-1 · Numbers · (2)

Page 159 of the Paradyne 3910 user manual — ATD9W5551234
Page 159 · click to enlarge
Page 159

AT Command Set and S-Registers

(1 of 3) 391x Series AT Commands

A/ Repeat Last Command. Reexecutes last command string. (Not to be preceded with AT or followed by pressing the Return key.)

A Answer Mode. Goes off-hook and attempts to establish a connection without waiting for a ring.

Dn Dial. Begins the dialing sequence. The dial string n (modifiers and telephone number) is entered after the D command.

Any digit 0–9, *, or # may be dialed as a DTMF tone. Only the digits 0–9 can be dialed in Pulse Dial mode. The following example shows how to dial through a PBX. The dial string consists of the command string and the telephone number:

ATD9W5551234

Modifiers include the following parameters:

T — Tone (DTMF) dial. Any digit 0–9, *, or # can be dialed as

tone.

P — Pulse dial. Only digits 0–9 can be dialed in Pulse Dial

mode.

only remain active until the end of that dial string. The modem defaults to the value set by the Dialer Type configuration option.

, — Pause. Causes the modem to pause before processing the

next character in the dial string. The length of this pause is determined by the setting of the Pause Time configuration option (refer to the Line Dialer configuration option group) or by value held in S-Register S8.

W — Wait for dial tone. The modem waits for a second dial tone

before processing the dial string. This can be the initial dial tone or can be used when dialing through a tandem PBX. For example, 9W 555-6789.

R — Reverse Dial mode. Causes the originating modem to

send out an answertone once it no longer detects ringback. (Ringback is the ring you hear at the originating site when making a call.) The R parameter must be the last character in the dial string. For correct operation, at least one ringback must be detected; therefore, the remote modem should be configured to answer on the second ring or subsequent rings.

Show 7 more labels / short text on this page
Table 5-2 · DCP LCD Command · AT Command Description · Sequence · Call Setup\ Answer · None · None
Page 160 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 160 · click to enlarge
Page 160

(2 of 3) 391x Series AT Commands

Dn (cont.) @ — Quiet answer. Wait for five seconds of silence after dialing

the number. If the silence is not detected, the modem sends either a NO ANSWER result to the DTE.

! — Hook flash. This causes the modem to go on-hook for 0.5

seconds then return to off-hook.

; — Return to Command mode. Modem returns to Command

mode after dialing a number without disconnecting the call.

Space — Ignored by the dial string, can be included to enhance

readability.

– — Ignored by the dial string, can be included to enhance

readability.

( ) — Ignored by the dial string, can be included to enhance

readability.

DS=n Dial Stored Number. Dials the number stored in Location n (1–24). (To store a telephone number, refer to the &Zn=x command.)

Call Setup\Dial\ Dial Directory:

En Command Character Echo.

E0 Disables echo to the DTE. E1 Enables echo to the DTE.

Hn Hook Switch Control.

H0Call Setup\ Disconnect or Control\Remove Make Busy

H0 Modem goes on-hook. H1 Modem goes off-hook.

H1Control\ Make Busy

In Identification.

I0 Displays product code — 144. 1 Displays 3-digit firmware revision number. I2 Performs an EPROM check.

Ln Speaker Volume.

L0 Selects low volume. L1 Selects low volume. L2 Selects medium volume. L3 Selects high volume.

Mn Speaker On/Off.

M0 Speaker always OFF. M1 Speaker ON until carrier signal is detected. M2 Speaker always ON.

Show 8 more labels / short text on this page
Table 5-2 · DCP LCD Command · AT Command · Sequence Description · Configure\Edit\ DTE Dialer · Status\Identity · Control\Speaker Configure\Edit\ Misc · Control\Speaker Configure\Edit\ Misc
Page 161 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 161 · click to enlarge
Page 161

AT Command Set and S-Registers

(3 of 3) 391x Series AT Commands

O Return to Online or Data Mode. Returns modem to Data mode from Online Command mode.

P Pulse Dial. Sets the modem for Pulse Dial mode. Configure\Edit\ Line Dialer

(1 of 8) 391x Series AT Commands

Qn Result Codes.

Q0 Enables modem to send result codes to the DTE. Q1 Disables modem from sending result codes to the DTE. Q2 Enables in Originate mode only for modem to send result codes to the DTE. Required for most UNIX applications.

Sn=r Change S-Register. Changes contents of S-Register (where n is the S-Register, and r is the new value).

Sn? Display S-Register. Displays value of S-Register where n is the S-Register number.

T Tone Dial. Sets the modem for tone dial mode. Configure\Edit\ Line Dialer

Vn Result Codes Format.

V0 Displays result codes in Number (1) format (digits). V1 Displays result codes as text. V2 Displays result codes in Number (2) format (digits).

Show 13 more labels / short text on this page
Table 5-2 · DCP LCD Command · AT Command · Sequence Description · None · Table 5-3 · DCP LCD Command · AT Command Description · Sequence · Configure\Edit\ DTE Dialer · None · None · Configure\Edit\ DTE Dialer
Page 162 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 162 · click to enlarge
Page 162

(2 of 8) 391x Series AT Commands

Xn Extended Result Code, Dial Tone Detect, and Busy Tone Detect Configuration Options.

Extended Result CodeConfigure\Edit\ DTE Dialer

Extended Dial Tone Busy Tone Result Code: Detect: Detect:

Dial Tone DetectConfigure\Edit\ Line Dialer

X0 Disable Disable Disable X1 Enable Disable Disable X2 Enable Enable Disable X3 Enable Disable Enable X4 Enable Enable Enable X5 Add/EC Enable Enable X6 Add/V42.MNP Enable Enable X7 Use DTE Rate Enable Enable

Busy Tone DetectConfigure\Edit\ Line Dialer

Extended Result Code:

Enable Displays all result codes listed in Table 5-1 except for error control suffix.

Disable Only displays OK, CONNECT, RING, NO CARRIER, ERROR ERROR.

Add/EC Displays result codes with /EC suffix.

Add/V42,MNP Displays result codes with V.42 or MNP suffix.

Use DTE Rate Displays DTE data rate instead of line rate.

Dial Tone Detect:

Enable Sets the modem for dial tone detect Enable Sets the modem for dial tone detect. Disable Sets the modem for blind dialing.

countries.

Busy Tone Detect:

Enable Modem monitors for busy tone. Disable Modem ignores busy tone.

Yn Long Space Disconnect.

Y0 Disable. Ignores long space. Y1 Enable. Disconnects if long space is detected. Enables transmission of a long space.

Show 5 more labels / short text on this page
Table 5-3 · DCP LCD Command · AT Command · Sequence Description · Configure/Edit/ Line Dialer
Page 163 of the Paradyne 3910 user manual — &D1,&D2,&D3
Page 163 · click to enlarge
Page 163

AT Command Set and S-Registers

(3 of 8) 391x Series AT Commands

Zn Reset and Load Active.

Z0 Loads configuration options from Active (Saved) to Active (Operating).

Z1 Loads configuration options from Customer 1 to Active (Operating).

Z2 Loads configuration from Customer 2 to Active (Operating).

Z3 Loads configuration options from Active (Saved) to Active (Operating) and performs a reset.

&Cn LSD Control.

&C0 Forced On. LSD ON at all times.

&C1 Standard RS232. LSD is ON when the remote modem’s carrier signal is detected. LSD is OFF when carrier signal is not detected.

&C2 Wink When Disconnect. LSD normally forced ON, turns OFF for approximately one second upon disconnecting.

&C3 Follows DTR. State of LSD follows state of DTR.

&C4 Simulated Control Carrier. State of LSD follows state of remote modem’s RTS.

&C5 =DTR/Disconnect Off. State of LSD follows state of DTR except upon a disconnect where DTR remains ON and LSD turns OFF. DTR must then toggle OFF and ON to turn LSD ON. Use this setting for AT&T DATAKIT applications. Note that to use this option, the DTR Action configuration option must be set to Stndrd_RS232 (&D1 or &D2).

&Dn DTR Action.

&D0 Ignore. Modem ignores the true status of DTR and treats it as always ON.

&D1,&D2,&D3

Standard RS232. DTR Signal is controlled by the DTE.

&D4 Controls On-Hook. Modem does not disconnect from the VF line until DTR turns OFF.

&D5 Controls Transmitter Mute. Mutes the transmitter whenever DTR drops on the DTE interface. This can be used on the answer side modem to force the originate modem to initiate a dial backup.

Show 7 more labels / short text on this page
Table 5-3 · DCP LCD Command · AT Command · Sequence Description · Control\Reset · Configure\Edit\ DTE Interface · Configure\Edit\ DTE Interface
Page 164 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 164 · click to enlarge
Page 164

(4 of 8) 391x Series AT Commands

&Fn Select Factory Default Configuration Options. Loads factory configuration options into Active (Operating) area.

&F0 Async Dial &F1 Sync Dial &F2 Sync Leased: Answer &F3 UNIX Dial &F4 Sync Leased: Originate &F5 Async Leased: Answer &F6 Async Leased: Originate &F7 TMp: Control &F8 TMp: Trib

Only the &F0 and &F3 commands will leave you in AT Command mode. The other commands will take you out of AT command control and place the modem into Dumb mode. The only way to return to AT command control is via the diagnostic control panel (DCP).

&Gn V.22bis Guard Tone.

&G0 Disable. &G1 550 Hz. &G2 1800 Hz.

&In Dial Transmit Level.

  • The AT command is & I n, where n is 0 for –1 dBm 1 for –1 dBm
  • 32 for –32 dBm NOTE : In North America the range of allowable values is –10 dBm to

–32 dBm. This command is disabled in some countries (it answers OK but does not change the level).

&Ln Leased Mode.

&L0 Disables leased-line operation. &L1 2-wire originate leased-line operation. &L2 4-wire originate leased-line operation. &L3 2-wire answer leased-line operation. &L4 4-wire answer leased-line operation.

The &L command will cause the modem to reset before entering or exiting Leased-Line mode. Therefore, it must be entered as the last command in an initialization string.

Show 8 more labels / short text on this page
Table 5-3 · DCP LCD Command · AT Command · Sequence Description · Configure/ Factory · Configure\Edit\ Dial Line · Configure\Edit\ Dial Line · Configure\Edit\ Leased Line
Page 165 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 165 · click to enlarge
Page 165

AT Command Set and S-Registers

(5 of 8) 391x Series AT Commands

Async/Sync Mode and DTE Dialer Type.

&M0, &Q0 Modem operates in Asynchronous mode and uses AT

Command protocol.

&M1, &Q1 Modem operates in Synchronous mode and uses AT

Command protocol.

&M2, &Q2 Modem operates in Synchronous mode and dials telephone

number stored in directory location 1 when DTR signal turns OFF and then ON.

&M3, &Q3 Modem operates in Synchronous mode and uses AT

Command protocol.

The &M2 and &Q2 commands disable the use of AT commands and force the modem into Dumb mode. The only way to gain control of the modem is via the DCP.

&Rn RTS Action.

&R0 Standard RS232. &R1 Ignores RTS. &R2 Simulated Control Carrier. &R3 Control Carrier.

&Sn DSR Control.

&S0 Forced On. &S1 Standard RS232. &S2 Wink When Disconnect. &S3 Follows DTR. &S4 On Early. &S5 Delay to DTE.

&Tn Tests.

&T0 Abort. Stops any test in progress. &T1 Local Analog Loop. &T2 Pattern. Transmits and receives a 511 Bit Error Rate Test (BERT). &T3 Local Digital Loopback test. &T4 Enables Receive Remote Loopback Response configuration option. &T5 Disables Receive Remote Loopback Response configuration option. &T6 Remote Digital Loopback test. &T7 Remote Digital Loopback with Pattern. &T8 Local Loopback with Pattern. &T9 Self-Test.

&T4 and &T5Configure\Edit\ Tests
Show 10 more labels / short text on this page
Table 5-3 · DCP LCD Command · AT Command · Sequence Description · &Mn and · Configure\Edit\ DTE Dialer · &Qn · Configure\Edit\ DTE Interface · Configure\Edit\ DTE Interface · Test
Page 166 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 166 · click to enlarge
Page 166

(6 of 8) 391x Series AT Commands

&Vn View Configuration Options. Displays each configuration group within the Active (Operating), Active (Saved), Customer 1, and Customer 2 configuration areas as well as the telephone numbers stores in directory locations 1–24.

&V0 Active (Operating) configuration options. &V1 Active (Saved) configuration options. &V2 Customer 1 configuration options. &V3 Customer 2 configuration options. &V4 Directory locations 1–24.

&Wn Write (Save to Memory). Saves the current configuration options in Active (Operating) to one of three configuration areas:

&W0 Saved to Active(Save). &W1 Saved to Customer 1. &W2 Saved to Customer 2.

&Xn Transmit Clock Source.

&X0 Internal. Modem provides transmit clock source for synchronous data (Pin 15). &X1 External. Modem derives external transmit clock source provided on Pin 24 for synchronous data. &X2 Receive Clock Loop. Modem derives transmit clock source from receive signal for synchronous data (Pin 17).

&Zn=x Store Telephone Numbers. Modem saves the telephone numbers and dial command modifiers (if any) entered for x (up to 40 characters in length) in Directory Location n (1–24). For example, the command AT&Z1 = 5551234 stores the telephone number 555-1234 into directory location 1.

Call Setup\ Change Directory

To clear a telephone number from a memory location, issue the &Zn=x command without entering a telephone number.

\An Maximum Frame Size.

\A0 64 bytes. \A1 128 bytes. \A2 192 bytes. \A3 256 bytes. \A4 32 bytes. \A5 16 bytes.

\Cn Error Control Negotiate Buffer.

\C0 Disable. \C1 Enable. \C2 Disables and switches modem to Buffer mode.

Show 9 more labels / short text on this page
Table 5-3 · DCP LCD Command · AT Command · Sequence Description · None · Configure\Save · Configure\Edit\ DTE Interface · Configure\Edit\ V42/MNP/Buffer · Configure\Edit\ V42/MNP/Buffer
Page 167 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 167 · click to enlarge
Page 167

AT Command Set and S-Registers

(7 of 8) 391x Series AT Commands

\Dn CTS Control.

\D0 Forced On. Forces CTS to always ON. \D1 Standard RS232. \D2 Wink When Disconnect. CTS is turned OFF for 1 to 2 seconds upon a disconnect. \D3 Follows DTR. The state of CTS follows the state of DTR. \D4 Follows RTS. The state of CTS follows the state of RTS.

\Gn Modem to Modem Flow Control.

\G0 Disable. \G1 Enable.

\Kn Buffer Control, Send Break Control, Break Forces Escape.

Break Buf fer ControlConfigure\Edit\ V42/MNP/

Break Buffer Send Break Break Forces Control: Control: Escape:

Send Break ControlConfigure\Edit\ V42/MNP/Buffer

\K0 Discard Data Break First Enable \K1 Discard Data Break First Disable \K2 Keep Data Break First Enable \K3 Keep Data Break First Disable \K4 Keep Data Data First Enable \K5 Keep Data Data First Disable

Break Forces EscapeConfigure\Edit\ DTE Dialer

\Nn Error Control Mode.

\N0 Buffer Mode. \N1 Direct Mode. \N2 MNP or Disconnect. \N3 MNP or Buffer. \N4 V.42/MNP or Disconnect. \N5 V.42/MNP or Buffer. \N6 LAPM_or_Disc \N7 LAPM_or_Bufr

\Qn Flow Control of DTE, Flow Control of Modem.

Flow Control Flow Control of DTE: of Modem:

\Q0 Disable Disable \Q1 XON/XOFF XON/XOFF \Q2 CTS to DTE Disable \Q3 CTS to DTE RTS to Mdm \Q4 XON/XOFF Disable \Q5 Disable XON/XOFF \Q6 Disable RTS to Mdm

Show 8 more labels / short text on this page
Table 5-3 · DCP LCD Command · AT Command · Sequence Description · Configure\Edit\ DTE Interface · Configure\Edit\ V42/MNP/Buffer · Configure\Edit\ V42/MNP/Buffer · Configure\Edit\ V42/MNP/Buffer
Page 168 of the Paradyne 3910 user manual — NOTE
Page 168 · click to enlarge
Page 168

(8 of 8) 391x Series AT Commands

\Tn No Data Disconnect Timer.

\T0 Disable. \Tn Where n is a value from 1 to 255 in 1-minute increments.

\Xn XON/XOFF Passthrough Flow Control.

\X0 Disable. \X1 Enable.

%An Error Control Fallback Character.

%An Where n is an ASCII value from 0 to 127. Factory default is 013 ASCII.

%Cn MNP5 Data Compression.

%C0 Disable. %C1 Enable.

″Hn V.42bis Compression.

″H0 Disable. ″H1 Enable. ″H2 Enable. ″H3 Enable.

S-Register List

S-Registers affect the operating parameters of the 391x Series modems. S-Registers are only applicable when the DTE Dialer Type configuration option is set for AT. (Refer to the &Mn and &Qn commands.)

Table 5-4 lists all S-Registers supported by the 391x Series modems. The first column lists the S-Register. The second column lists all possible values for that register. The third column lists the key sequence used to enter the equivalent from the DCP. Use this column to reference commands in Chapter 4 if further description is necessary.

NOTE

In some countries, the range of allowable values of some S-Registers are restricted. If the DTE attempts to enter an illegal value, the modem will answer OK, but it will set the register to the closest legal value. The DTE can check the actual value of the register with Sn? command.

Show 9 more labels / short text on this page
Table 5-3 · DCP LCD Command · AT Command · Sequence Description · Configure\Edit\ Line Dialer · Configure\Edit\ V42/MNP/Buffer · Configure\Edit\ V42/MNP/Buffer · Configure\Edit\ V42/MNP/Buffer · Configure\Edit\ V42/MNP/Buffer
Page 169 of the Paradyne 3910 user manual — S-Register Format
Page 169 · click to enlarge
Page 169

AT Command Set and S-Registers

S-Register Format

S-Registers can be displayed and/or modified when the modem is in Command mode. To display the value of an S-Register, issue the following command:

TYPE: ATSn?

Where: n is the register number.

PRESSEnter

To modify the value of an S-Register, issue the following command:

TYPEATS n = r

Where: n is the register number, and r is the new value.

PRESSEnter

In Table 5-4, the value for n is listed in the S-Register column, and the value for r is listed in the Description column.

(1 of 13) 391x Series S-Registers

S0 Auto-Answer Ring Number1. Register determines number of rings the modem will count before automatically answering a call.

Enter zero (0) if you do not want the modem to automatically answer any calls. Otherwise, enter a value from 1–255 for the number of rings to count before answering. The factory setting is 1.

S2 AT Escape Character. Register determines ASCII value used for escape sequence to enter Command mode from Data mode.

Enter a value from 0 to 127 for the escape character. Any value greater than 127 causes the modem to disable the escape sequence. When the escape sequence is disabled, the modem cannot return to Command mode until the call is disconnected. The factory setting is 43 (+ key).

S3 Carriage Return Character. Register determines ASCII value used as the carriage return (Return key). This character is used to end command lines and result codes.

Enter a value from 0 to 127 for the command end character. The factory setting is 13 (carriage return key).

S4 Line Feed Character. Register determines ASCII value used as the line feed character.

Enter a value from 0–127 for the line feed character. The factory setting is 10 (ASCII carriage return or line feed).

1 The range of allowable values may be restricted in some countries.

Show 8 more labels / short text on this page
Table 5-4 · DCP LCD Command · S-Register Description · Sequence · Configure\Edit\ Line Dialer · Configure\Edit\ DTE Dialer · Configure\Edit\ DTE Dialer · Configure\Edit\ DTE Dialer
Page 170 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 170 · click to enlarge
Page 170

(2 of 13) 391x Series S-Registers

S5 Backspace Character. Register determines ASCII value used as the backspace (Backspace key). This character moves the cursor to the left and erases the previous character.

Enter a value from 0–127. The factory setting is 8 (backspace key).

S6 Blind Dial Pause1. Register determines how long (in seconds) the modem waits after going off-hook before dialing a telephone number if using result code X0, X1, or X3.

Enter a value from 2–255 seconds. The factory setting is 2.

S7 No Answer Time-out1. Register determines how long (in seconds) an originating modem waits before abandoning a call when no answer tone is received.

Enter a value from 1–255 seconds. The factory setting is 45.

S8 “,” Pause Time for the Dial Modifier. Register determines how long (in seconds) the modem pauses when it encounters a comma (,) in the Dial command string.

Enter a value from 0–255 seconds. The factory setting is 2.

S10 No Carrier Disconnect1. Register determines how long (in tenths of seconds) the modem allows the carrier signal to be OFF before disconnecting the call.

Enter a value from 0–254 in 0.1 second increments. A value of 255 disables this register. The factory setting is 20 (2 seconds).

S12 Escape Guard Time. Register sets the value (in 20-millisecond increments) for the required pause before and after the escape sequence is issued. The guard time prevents the modem from interpreting data as the escape sequence characters.

Enter a value from 0–255 in 20-millisecond increments. The factory setting of 50 equals 1000 milliseconds or one second.

S18 Test Time-out. Register sets the duration (in seconds) for the modem tests. This automatically cancels any test in progress after the time of this register expires. Any test can be manually canceled by issuing the escape sequence (+++) followed by the &T0 command.

Enter a value from 0–255 seconds. A value of 0 disables this register. The factory setting is Disable (0).

S26 RTS-to-CTS Delay. Register sets the length of time (in 10-millisecond increments) the modem waits after receiving RTS before issuing CTS to the DTE.

Enter a value from 0–255. The factory setting is 0.

1 The range of allowable values may be restricted in some countries.

Show 12 more labels / short text on this page
Table 5-4 · DCP LCD Command · S-Register · Sequence Description · Configure\Edit\ DTE Dialer · Configure\Edit\ Line Dialer · Configure\Edit\ Line Dialer · Configure\Edit\ Line Dialer · Configure\Edit\ Line Dialer · Configure\Edit\ DTE Dialer · Configure\Edit\ Tests · Configure\Edit\ DTE Interface
Page 171 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 171 · click to enlarge
Page 171

AT Command Set and S-Registers

(3 of 13) 391x Series S-Registers

S40 Auto Make Busy. Register determines if the modem goes off-hook under certain conditions. This register should only be enabled when the modem is located behind a user’s Private Branch Exchange (PBX). This register is only valid for Model 3911 modems.

Register has the following values:

0 = Disable 1 = Enable

The factory setting is Disable.

S41 Dial-Line Rate. Register determines the modem’s data rate and modulation scheme for operation on dial lines.

Register has the following values:

1 = 14,400 (V.32bis) 2 = 12,000(V.32bis) 3 = 9600 (V.32bis) 4 = 7200 (V.32bis) 5 = 4800 (V.32bis) 6 = 2400 (V.22bis) 7 = 1200 (V.22) 8 = 1200 (212A) 10 = 0-300 (V.21) 11 = 0-300 (103J) 12 = 1200/75 (V.23) 13 = 75/1200 (V.23) 18 = 600/75 (V.23) 19 = 75/600 (V.23) 20 = 19,200 (V.32 terbo) 21 = 16,800 (V.32 terbo)

The factory setting is 19200 (V.32 terbo).

S43 V.32bis Train. Register controls the modem’s train time for V.32bis/V.32 mode.

Register has the following values:

0 = Long 1 = Short

The factory setting is Long.

Show 7 more labels / short text on this page
Table 5-4 · DCP LCD Command · S-Register · Sequence Description · Configure\Edit\ Line Dialer · Configure\Edit\ Dial Line · Configure\Edit\ Dial Line
Page 172 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 172 · click to enlarge
Page 172

(4 of 13) 391x Series S-Registers

S44 Leased-Line Rate. Register determines the modem’s data rate and modulation scheme for operation on either 2-wire or 4-wire leased lines in either Answer or Originate mode.

Register has the following values:

1 = 14,400 (V.32bis) 2 = 12,000 (V.32bis) 3 = 9600 (V.32bis) 4 = 7200 (V.32bis) 5 = 4800 (V.32bis) 6 = 2400 (V.22bis) 11 = 14,400 (V.33) 12 = 12,000 (V.33) 13 = 9600 (V.29) 14 = 7200 (V.29) 15 = 4800 (V.29) 16 = 4800 (V.27) 17 = 2400 (V.27bis) 18 = 19,200 (V.32 terbo) 19 = 16,800 (V.32 terbo) 20 = 19,200 (TMp) 21 = 14,400 (TMp) 22 = 9600 (TMp) 23 = 7200 (TMp) 24 = 4800 (TMp) 25 = 2400 (TMp)

The factory setting is 19200 (V.32 terbo).

S45 Leased Tx Level2. Register determines the modem’s transmit power output level over leased lines.

Enter a value from 0 to –15 dBm. The factory setting is 0 dBm.

S46 Auto Dial Backup. Register determines if the modem performs an automatic dial backup if the leased lines fail.

Register has the following values:

0 = Disable 1 = Enable

The factory setting is Disable.

2 The range of allowable values is 0 through 15 in North America, and 1 through 15 in other countries. The default is country dependent.

Show 7 more labels / short text on this page
Table 5-4 · DCP LCD Command · S-Register · Sequence Description · Configure\Edit\ Leased Line · Configure\Edit\ Leased Line · Configure\Edit\ Leased Line
Page 173 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 173 · click to enlarge
Page 173

AT Command Set and S-Registers

(5 of 13) 391x Series S-Registers

S47 Auto Dial Standby. Register determines if the modem performs an automatic dial standby if in Dial Backup mode.

Register has the following values:

0 = Disable 1 = 15 minutes 2 = 1 hour 3 = 4 hours 4 = Test(2min) 5 = Adv 15min 6 = Adv 30min 7 = Adv 1 hr 8 = Adv2minTest

The factory setting is Disable.

S48 Leased-Line Carrier On Level. Register determines if the modem disconnects if the carrier signal on leased lines falls below –26 dBm or –43 dBm.

Register has the following values:

0 = –43 dBm 1 = –26 dBm 2 = –33 dBm

The factory setting is country dependent (usually –43 dBm). In France, the factory setting is –26 dBm in 4-wire operation and –33 dBm in 2-wire operation.

S49 Buffer Disconnect Delay. Register determines how long the modem continues to transmit data stored in its buffers when the modem is commanded to disconnect by a locally attached DTE.

Enter a value from 0–255 seconds. (A value of 0 disables this register.) The factory setting is 10 seconds.

S51 DTE RL (CT140). Register determines if the modem performs a remote digital loopback if it receives a CT140 signal from the DTE.

Register has the following values:

0 = Disable 1 = Enable

The factory setting is Disable.

S52 DTE LL (CT141). Register determines if the modem performs a local analog loopback if it receives a CT141 signal from the DTE.

Register has the following values:

0 = Disable 1 = Enable

The factory setting is Disable.

Show 9 more labels / short text on this page
Table 5-4 · DCP LCD Command · S-Register · Sequence Description · Configure\Edit\ Leased Line · Configure\Edit\ Leased Line · Configure\Edit\ V42/MNP/Buffer · Configure\Edit\ Tests · Configure\Edit\ Tests
Page 174 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 174 · click to enlarge
Page 174

(6 of 13) 391x Series S-Registers

S53 V.54 Address. Identifies the address of the modem to be placed in a loopback test.

Register has the following values:

0 = Disable 1–34 = Modem address

The factory setting is Disable.

S54 V.54 Device Type. Identifies where the modem is physically located in the network.

Register has the following values:

0 = Peripheral 1 = Intermediate

The factory setting is Peripheral.

S55 Access From Remote. Register determines if a modem’s DCP can be accessed by a remote modem.

Register has the following values:

0 = Enable 1 = Disable

The factory setting is Enable.

S56 Remote Access Password. Register allows entry of the first pair (leftmost) of digits of a remote access password. Any value from 00 to 99 is valid. For example, if the remote access password is 12345678, then S56 = 1 and 2.

S57 Remote Access Password. Register allows entry of the second pair of digits of a remote access password. Any value from 00 to 99 is valid.

S58 Remote Access Password. Register allows entry of the third pair of digits of a remote access password. Any value from 00 to 99 is valid.

S59 Remote Access Password. Register allows entry of the fourth pair (rightmost) of digits of a remote access password. Any value from 00 to 99 is valid.

Show 11 more labels / short text on this page
Table 5-4 · DCP LCD Command · S-Register · Sequence Description · Configure\Edit\ Tests · Configure\Edit\ Tests · Configure\Edit\ Misc · Configure\Edit\ Misc · Configure\Edit\ Misc · Configure\Edit\ Misc · Configure\Edit\ Misc
Page 175 of the Paradyne 3910 user manual — 0 = ASCII 1 = EBCDIC
Page 175 · click to enlarge
Page 175

AT Command Set and S-Registers

(7 of 13) 391x Series S-Registers

S61 CT111 Rate Control. Register determines if CT111 Rate is disabled, set for Fallback 1 or Fallback 2.

CT111 Rate allows the DTE to control modem rate via Pin 23 of the EIA-232-D interface. This configuration option determines the effect of the DTE Rate Control signal. It is only valid in Async Direct mode and Synchronous mode. For proper operation, disable the V.32bis Autorate and V.32bis Automode configuration options.

Register has the following values:

0 = Disable 1 = Fallback 2 = Fallback 2

The factory setting is Disable.

S62 V.25bis Coding. Register identifies to the modem the type of coding used by the DTE while in V.25bis mode.

Register has the following values:

0 = ASCII 1 = EBCDIC

The factory setting is ASCII.

S63 V.25bis Idle Character. Register identifies to the modem the type of idle fill used by the DTE while in V.25bis mode.

Register has the following values:

0 = Mark 1 = Flag

The factory setting is Mark.

S64 V.25bis New Line Character. Register identifies to the modem the type of line terminator used by the DTE while in V.25bis mode.

Register has the following values:

0 =Carriage Return and Line Feed 1 =Carriage Return 2 =Line Feed

The factory setting is carriage return and line feed (CR + LF).

S65 Line Current Disconnect. Register determines if the modem disconnects if an 8-millisecond or 90-millisecond interruption in loop current occurs.

Register has the following values:

0 = Enable (8msec) 1 = Enable (90msec) 2 = Disable

The factory setting is Enable (8msec).

Show 9 more labels / short text on this page
Table 5-4 · DCP LCD Command · S-Register · Sequence Description · Configure\Edit\ DTE Interface · Configure\Edit\ DTE Dialer · Configure\Edit\ DTE Dialer · Configure\Edit\ DTE Dialer · Configure\Edit\ Line Dialer
Page 176 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 176 · click to enlarge
Page 176

(8 of 13) 391x Series S-Registers

S66 NMS Call Messages. Register determines if the modem sends information regarding status (Call Progress) and/or sends summarized call statistics (Call Connect) to the 6700 Series Network Management System (NMS).

Register has the following values:

0 = Call Connect & Progress 1 = Disable 2 = Call Connect Only 3 = Call Progress Only

The factory setting is Call Connect & Progress.

S67 Directory Location 1 Callback. Register determines if the modem uses the single number callback function.

Register has the following values:

0 = Disable 1 = Enable

The factory setting is Disable.

S69 Make Busy Via DTR. Register determines if the modem goes off-hook (busy) when DTR is OFF.

Register has the following values:

0 = Disable 1 = Enable

The factory setting is Disable.

S70 V.27bis Train. Register controls the train time for V.27bis operation.

Register has the following values:

0 = Short 1 = Long

The factory setting is Short.

S71 XTXC Clamps TXC. Register allows the modem’s TXC output to be clamped off when TX Clock Source is configured for External.

Register has the following values:

0 = Enable 1 = Disable

The factory setting is Enable.

Show 9 more labels / short text on this page
Table 5-4 · DCP LCD Command · S-Register · Sequence Description · Configure\Edit\ Misc · Configure\Edit\ Misc · Configure\Edit\ Line Dialer · Configure\Edit\ Leased Line · Configure\Edit\ DTE Interface
Page 177 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 177 · click to enlarge
Page 177

AT Command Set and S-Registers

(9 of 13) 391x Series S-Registers

S72 RTS Antistreaming. Register determines the antistreaming operation of the modem.

Register has the following values:

0 = Disable 1 = 10 sec 2 = 30 sec 3 = 1 min 4 = 2 min 5 = 3 min 6 = 5 min

The factory setting is Disable.

S74 Network Position Identification. Register identifies each modem as either a control or tributary modem.

Register has the following values:

0 = Tributary 1 = Control

The factory setting is Tributary.

S75 Network Management Address. Register determines the modem’s network address. This address is used when accessing the modem from the 6700 Series NMS.

Enter a value from 0 (network address 001) to 255 (network address 256). The factory setting is 0.

S76 V.32bis Autorate (Dial Line). Register determines if Autorating is used on dial lines when connected in V.32bis mode.

Register has the following values:

0 = Enable 1 = Disable

The factory setting is Enable.

S78 V.32bis Automode (Dial Line). Register allows the modem (when operating on dial lines) to automatically detect and connect to the remote modem’s modulation scheme.

Register has the following values:

0 = Enable 1 = Disable

The factory setting is Enable.

Show 9 more labels / short text on this page
Table 5-4 · DCP LCD Command · S-Register · Sequence Description · Configure\Edit\ DTE Interface · Configure\Edit\ Misc · Configure\Edit\ Dial · Configure\Edit\ Dial Line · Configure\Edit\ Dial Line
Page 178 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 178 · click to enlarge
Page 178

Table 5-4 (10 of 13) 391x Series S-Registers

S82 V.32bis Autorate (Leased Line). Register determines if Autorating is used on leased lines when connected in V.32bis mode.

Register has the following values:

0 = Enable 1 = Disable

The factory setting is Enable.

S84 AT Command Mode. Register determines how the modem responds to valid and invalid AT commands.

Register has the following values:

0 = Normal 1 = No ERROR 2 = No Strap or ERROR

The factory setting is Normal.

S85 Fast Disconnect. Register allows the modem to disconnect immediately after receiving a disconnect command from a local DTE or its own diagnostic control panel.

Register has the following values:

0 = Disable 1 = Enable

The factory setting is Disable.

S88 Straps When Disconnected. Register determines whether or not configuration options in the Active (Saved) configuration area are reloaded to Active (Operating) when a disconnect occurs.

Register has the following values:

0 or 231 = No Change 1 or 232 = Reload

The factory setting is No Change.

Show 7 more labels / short text on this page
DCP LCD Command · S-Register · Sequence Description · Configure\Edit\ Leased Line · Configure\Edit\ DTE Dialer · Configure\Edit\ Line Dialer · Configure\Edit\ Misc
Page 179 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 179 · click to enlarge
Page 179

AT Command Set and S-Registers

Table 5-4 (11 of 13) 391x Series S-Registers

S89 V.42 Automatic Request for Retransmission (ARQ) Window Size Increase. Register allows the ARQ window size to be set to a value from six frames to fifteen frames.

For best performance, this register should remain at its default setting of six frames (ATS89 = 0). The only reason to change it is for satellite delays.

Register has the following values:

0 = six frames 1 = seven frames 2 = eight frames 3 = nine frames 4 = ten frames 5 = eleven frames 6 = twelve frames 7 = thirteen frames 8 = fourteen frames 9 = fifteen frames

The factory setting is 0 (six frames).

This command only applies when the modem connects using V.42bis data compression or V.42 error control. If the modem is configured for Direct mode, MNP mode, Buffer mode, or Synchronous operation, this command is invalid.

This command does not have a front panel equivalent.

S90 DTE Rate = VF. Register allows the DTE’s data rate to be equal to the VF (telephone line) data rate. If Enabled, the data rate between the DTE and modem is the same as the modem’s VF data rate. As a result, when the modem is in Data mode, the speed of the data passed between the modem and DTE occurs at the VF data rate.

Register has the following values:

0 = Disable 1 = Enable

The factory setting is Disable.

S91 Cellular Enhancement. Register allows the modem to use non-standard techniques to enhance V.42 operation for cellular applications. It is still compatible, however, with modems which do not have the cellular enhancement implemented or enabled.

Register has the following values:

0 = Disable 1 = Enable

The factory setting is Disable.

Show 5 more labels / short text on this page
DCP LCD Command · S-Register · Sequence Description · Configure\Edit\ DTE Interface · Configure\Edit\ V42/MNP/Buffer
Page 180 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 180 · click to enlarge
Page 180

Table 5-4 (12 of 13) 391x Series S-Registers

S92 V.29 Train On Data. When enabled, the modem receiver can train based upon the incoming data or a training sequence from the distant modem. This function is necessary for a remote (tributary) modem in a V.29 multipoint network and is recommended for a control modem as well.

Register has the following values:

0 = Disable 1 = Enable

The factory setting is Disable.

S93 V.29 Retrain. When enabled, the modem transmits a training sequence whenever it receives one. This configuration option should normally be disabled for control modems.

Register has the following values:

0 = Enable 1 = Disable

The factory setting is Enable.

S94 V29 Link Configuration. Selects point-to-point or multipoint operation.

Register has the following values:

0 = PointToPoint 1 = Multipoint

The factory setting is PointToPoint.

S95 Trellis Multipoint (TMp) Train Time. Defines the length of time energy is sent from the tributary modem to the control modem. More severe line conditions require longer time selections.

Register has the following values:

0 = 10 milliseconds 1 = 20 milliseconds 2 = 50 milliseconds 3 = 100 milliseconds 4 = 200 milliseconds 5 = 300 milliseconds

The factory setting is 0 (10 milliseconds).

S96 Trellis Multipoint (TMp) Tx Preemphasis. Provides amplification for frequencies above the carrier frequency to compensate for high frequency line attenuation.

Register has the following values:

0 = Enable 1 = Disable

The factory setting is Enable.

Show 8 more labels / short text on this page
DCP LCD Command · S-Register · Sequence Description · Configure\Edit\ Leased · Configure\Edit\ Leased · Configure\Edit\ Leased · Configure\Edit\ Leased · Configure\Edit\ Leased
Page 181 of the Paradyne 3910 user manual — AT Command Set and S-Registers
Page 181 · click to enlarge
Page 181

AT Command Set and S-Registers

Table 5-4 (13 of 13) 391x Series S-Registers

S97 Reduced Asynchronous Buffer Size. Register limits the modem’s buffer size to a maximum of 20 characters.

Register has the following values:

0 = Disable 1 = Enable

The factory setting is Disable.

S98 Special Standby. Supports automatic dial standby when a third modem is used for dial backup.

Register has the following values:

0 = Disable 1 = Enable

The factory setting is Disable.

Show 5 more labels / short text on this page
DCP LCD Command · S-Register · Sequence Description · Configure\Edit\ V42/MNP/Buffer · Configure\Edit\ Leased
Page 182 of the Paradyne 3910 user manual — Dial Access Security
Page 182 · click to enlarge
Page 182

Dial Access Security

Chapter 6, Dial Access Security, is not available for viewing online because it contains security-sensitive information. Dial Access Security information is available in the COMSPHERE 3900 Series Modems Models 3910 and 3911 Point-To-Point/Multipoint Installation and Operation Manual, Document No. 3910-A2-GN32-30.

To order product documentation contact your sales representative.

Page 183 of the Paradyne 3910 user manual — Overview
Page 183 · click to enlarge
Page 183

A

Menu Tree

Overview A-1

Overview

Pages A-2 and A-3 provide a menu tree for the 391x Series modems.

A-1 3910-A2-GN32-30 November 1996

Page 184 of the Paradyne 3910 user manual — VF
Page 184 · click to enlarge
Page 184

Displays current status of modem along with data rate and error control mode. “Status”

Ld EditArea frmDisplay Clear Change Add Acquire

Activ (Operating) Customer2 Factory

VF

Answer Originate Major Minor Status Dial Thresh Security Port1

Ser# Mod# FRev HPt# FPt#

Line = Pri 4W APL Line = Pri 2W APL Line = Bkup 2W APL Line = Dial Backup Line = Dial ONLY Line = No Sync

LSD DTR DSR Tst TXD RXD RTS CTS

1 These parameters will appear for V.32 terbo, V.32bis, and V.32 modulations.

Active (Saved) Customer1 Customer2

2 These parameters will appear for Trellis Multi- point modulation.

(Sync-Leased Template only)

DTE_Interface Async/Sync Mode Async DTE Rate Asyn #Data Bits Asyn Parity Bit Asyn #Stop Bits DTR Action DSR Control RTS Action RTS Antistream CTS Control RTS/CTS Delay LSD Control TX Clock Source Bakup_TXClk_Src XTXC Clamps TXC CT111_Rate Cntl DTE_Rate=VF Extend Main Ch. Upstream Port

DTE_Dialer DTE Dialer Type AT Escape Char Escape GuardTim BreakForceEscap CommandCharEcho CarriageRtn Char Backspace Char Linefeed Char Result Codes ExtendResltCode ResultCode Form AT Cmnd Mode V25bis Coding V25bis IdleFill V25b NewLineChr

Line_Dialer AutoAnswerRing# Dialer Type DialTone Detect Blind Dial Paus BusyTone Detect “,” Pause Time NoAnswer Timout Fast Disconnect Line Crnt Disc Long Space Disc No Carrier Disc No Data Disc Auto Make Busy MakeBusyVia DTR

Dial_Line Dial Line Rate V32bis Automode V32bis Autorate V32bis_Override Dial TX Level V22b Guard Tone V32bis Train

Leased_Line Leased Mode LeasedLine Rate V32bis Autorate V32bis Override Leased TX Level Auto Dial Back AutoDialStandby SpecialStandby DialStandby Time CarrierOn Level V27bis Train V29 TrainOnData V29 Retrain V29 Link Config TMp Train Time TMp TxPreemphasis Lease_Lookback Dual_Leased_Ln BackupLineCheck

A-2 November 1996 3910-A2-GN32-30

Show 34 more labels / short text on this page
to next page · Status Configure PList · (Tributary · only) · Active Delete Skip · Customer1 · Active (Saved) · Sync_Leased · TMp · Sync_Dial · UNIX_Dial · Async_Leased · Async_Dial · Choose Mode · Record · Choose Mode · DeviceHS · Identity · Backup · DTE Options · Control Trib · Display Clear · SigQual1 · RcvLevel1,2 · Sig/Noise1,2 · NrEchLvl1 · Choose Function · FarEchLvl1 · FarEchDel1 · EchoFreqOff1 · NonLnearDist2 · Edit StrapGroup Save · Retrains2 · to next page
Page 185 of the Paradyne 3910 user manual — Menu Tree
Page 185 · click to enlarge
Page 185

Control SubHS Call_Setup Tlk/Data Remote

Choose Address (TMP Control only)

(Does not appear in North America)

Choose Password

(TMP only)

Directory Locations 1 – 24

(Not in TMp Trib)

Secondary Prim (data blckd)

(ExitRem appears instead of Remote when using Remote mode)

Does not appear in TMp Control mode.

V42/MNP/Buffer Err Contrl Mode V42bis Compress MNP5 Compress EC Negotiat Bfr EC Fallbck Char Flw Cntl of DTE Flw Cntl of Mdm XON/XOFF Psthru Mdm/Mdm FlowCtl Break Buffr Ctl Send Break Cntl BuffrDiscDelay Max Frame Size CellularEnhance RdcdAsyncBufSiz

Test DTE RL (CT140) DTE LL (CT141) Test Timeout Rcv Remote Loop V54 Address V54 Device Type

Misc StrapsWhenDisc Speaker Control Speaker Volume Access frm Remt RemAccssPasswrd Dir#1_Callback NMS_Call_Msgs NetworkPosition NetMngmtAddress Diag Connection Link Delay(sec)

Security EntryWait_Time VF_Prompt_Type #DTE_PW_Tries DTE_PW_TermChar DTE_PW_BkSpChar Get_User_ID NMS_Reporting Answ_Secur_Mode Originate_Secur

Does not appear in Remote mode. (Self, Loc_Digital_Loop, and Pattern appear if the secondary channel is used. Rem_Digital_Loop does not appear in TMp mode.)

Does not appear if configured for Synchronous mode.

Some choices within this group may not appear depending upon how previous configuration options have been selected.

A-3 3910-A2-GN32-30 November 1996

Show 48 more labels / short text on this page
Menu Tree · from previous page · · · · (Dial Backup · Security Test · only) · Dial Answer Change_Directory · · · Directory_Status · Disconnect Dial_Standby · · · or Return_to_Dial · · Self Rem_Digital_Loop Pattern · · · Abort Loc_Analog_Loop Loc_Digital_Loop · · · Set_Access_Ctrl Reset_Security · (Admin Password?) · (3910 · (3911 · only) · only) · EditPassWdTable · Set_Orig_Secur · Reset · Make_Busy · Download_Code (DownloadSoftware) · or RemoveMakeBusy · Set_Answer_Sec · Set_Admin_PsWd · Speaker · Data_Stream · VF_Thresh_Update EIA_LEDS · Service_Line · or DiscServLine · from previous page · · · · ·
Page 186 of the Paradyne 3910 user manual — Overview
Page 186 · click to enlarge
Page 186

B

Troubleshooting

Overview B-1

Overview

This appendix points out basic problems that can occur when operating a 391x Series modem. Use Tables B-1 through B-6 to check out these problems. If you are having data communication difficulties, such as periodic character loss, random errors, or constant format errors, use the loopback tests described in the Test section of Chapter 4. With these tests you can usually isolate the fault in your system by using the process of elimination. If problems continue to occur, contact your service representative.

Table B-1 Modem Health

The modem did not pass the power-up self-test.

Contact your service representative.

The power LED does not light or the LCD does not display information.

Make sure the modem’s ON/OFF switch is in the ON position.

Make sure the power supply is connected to the dc power receptacle on the modem.

If the Power LED and/or LCD do not operate, contact your service representative.

A problem is suspected after the power-up self-test.

Perform a self-test via the modem’s DCP or type AT&T9 if using AT commands.

Perform a local analog loopback with a Pattern test. If the modem consistently registers errors, contact your service representative.

If the modem passes the above tests and a problem still exists, then the problem is probably not with your modem.

B-1 3910-A2-GN32-30 November 1996

Symptom Action

Page 187 of the Paradyne 3910 user manual — Troubleshooting
Page 187 · click to enlarge
Page 187

Table B-2 Leased-Line Operation

The modems do not train-up on leased lines.

Verify that the correct cabling is used for your application. Refer to Chapter 2, Modem Installation.

Verify that one modem is configured for Answer mode and the other is configured for Originate mode. (For TMp operation one modem must be configured as a control modem and the other as a tributary modem.)

Verify that both modems are using the same modulation scheme.

Verify that both modems are configured for the appropriate leased-line mode. For example, if you have a 4-wire leased line, then the modems must be configured for 4-wire operation.

Table B-3 Dial Backup Operation

The dial backup line is present, but the modems cannot connect.

Verify that the correct telephone number for the remote modem is stored in directory location 1.

Verify that both modems have the Auto Dial Backup configuration option set to Enable. Refer to Leased Line in Chapter 4.

Call the answering modem with a handset and verify that the modem’s answer tone is transmitted.

The modem does not switch back to leased-line operation.

Verify that the Auto Dial Standby configuration option is enabled. Refer to Leased Line in Chapter 4.

B-2 November 1996 3910-A2-GN32-30

Symptom Action · Symptom Action

Page 188 of the Paradyne 3910 user manual — Troubleshooting
Page 188 · click to enlarge
Page 188

Table B-4 Modem — DTE Connection

The modem does not accept or echo back AT commands.

Verify that the cable between the Async port of the DTE and the modem is a standard RS-232 cable. (Null modem cables, also known as crossover cables, do not work in this application.)

Verify that the Command Character Echo configuration option is enabled. Refer to DTE Dialer in Chapter 4.

Verify that the DTE Dialer Type configuration option is set to AT. Refer to DTE Dialer in Chapter 4.

Verify that the Result Codes configuration option is enabled. Refer to DTE Dialer in Chapter 4.

Reload the Async Dial factory configuration area to guarantee that all configuration options are returned to their proper setting.

Make sure that all AT commands are terminated with a carriage return.

Verify that the Carriage Return Character configuration option matches what is used by the DTE. Refer to DTE Dialer in Chapter 4.

Verify that the DTE has a valid character format. Valid format consists of 8 data bits with no parity or 7 data bits with even, odd, mark or space parity.

Verify that the DTE’s data rate is supported by the modem. Refer to the Async DTE Rate configuration option in the DTE Interface section of Chapter 4.

If using a PC, verify that the modem is attached to the correct communications port.

B-3 3910-A2-GN32-30 November 1996

Troubleshooting · Symptom Action

Page 189 of the Paradyne 3910 user manual — Troubleshooting
Page 189 · click to enlarge
Page 189

(1 of 2) Modem — VF Connection

The modem does not receive a dial tone.

Attach a telephone directly to the telephone line to verify that a dial tone exists.

Make sure the VF line is connected to the modem’s rear jack labeled DIAL.

The modem does not go off-hook and answer an incoming call.

Verify that the Auto Answer Ring Count configuration option is set to a value other than 0 (disable). Refer to Line Dialer in Chapter 4.

Verify that the DTE is providing DTR to the modem.

If the DTE does not provide DTR to the modem, verify that the modem’s DTR Action configuration option is set for Ignore. Refer to DTE Interface in Chapter 4.

Verify that all cables are attached to the correct connectors on the rear of the modem.

The modem goes off-hook, answers, but does not connect.

Perform a Local Analog Loopback test and verify that data entered at the DTE is echoed back to the DTE.

Verify that the originating modem is compatible with your receiving modem.

Verify that the originating modem recognizes your modem’s answer tone.

Verify that the originating modem supports your modem’s modulation schemes. The 391x Series modem recognizes CCITT V.32bis, V.32, V.22bis, V.22, V.21, Bell 212A, and Bell 103J. The 391x Series modem does not support other vendors’ proprietary modulation schemes.

Force your modem to operate at the same modulation scheme as the originating modem to see if they connect.

The Originate Mode does not function properly.

Verify that the modem’s DTE Dialer Type configuration option is set to the correct setting: either AT, DTR Dialing, V.25bis Async, V.25bis Bisync, or V.25bis HDLC. Refer to DTE Dialer in Chapter 4.

The modem does not go off-hook and begin dialing.

If using AT Dialing, refer to the Table B-2, Modem—DTE Connection.

If using DTR Dialing, verify the telephone number stored in directory location 1, and verify that the DTE is raising DTR from Off to ON to initiate a dial.

If using V.25bis Async, verify that the correct character format is set to 7 data bits with even parity and 1 stop bit, and the carriage return and line feed are used as command terminators.

If using V.25bis Bisync, verify that the correct character format uses two synchronous control characters and a start-of-text control character before the text block, and an end-of-text control character after the text block.

If using V.25bis HDLC, verify that the character format uses flag, address, and control characters before the text block and a frame sequence check and flag after the text block.

B-4 November 1996 3910-A2-GN32-30

Table B-5 · Symptom Action

Page 190 of the Paradyne 3910 user manual — Troubleshooting
Page 190 · click to enlarge
Page 190

(2 of 2) Modem — VF Connection

The modem dials but does not connect.

If the modem is operating behind a PBX, determine if a 9 and comma are needed before the telephone number.

Verify whether Tone or Pulse dialing is needed.

Verify that both modems are configured the same in regard to Error Control. Try calling in Buffer mode.

If both modems use V.32bis or V.32 modulation, try setting the modem’s V.32bis Train configuration option to Long.

Intermittent disconnects, high error rates, or excessive retransmissions occur.

Perform an End-to-End test. Refer to Pattern located in the Test Branch section of Chapter 3.

The modem establishes and then disconnects the call.

You may have a poor VF connection. Try dialing again.

The remote modem may have encountered an error control (EC) disconnect. If the modems cannot negotiate EC, then a disconnect occurs.

The remote modem may be in a forced Error Control mode (disconnect if there is no error control). Reconfigure your modem to V.42/MNP or Buffer and try again.

Check the LCD to determine the reason for the disconnect.

Perform a Local Analog Loopback test.

High error rates occur when running a local loopback or self-test.

Incoming rings can cause data errors during a loopback test. Abort the test, disconnect the modular VF cord, and restart the test.

Table B-6 Online Operation

The data is scrambled. Verify that the character format (data bits, parity, and stop bits) is set to the same value in both modems.

Data is missing during a transfer. Verify that you are using the same method of flow control for both the modem and the DTE.

If using XON/XOFF flow control, verify that the modem’s parity matches the DTE’s parity.

B-5 3910-A2-GN32-30 November 1996

Show 4 more labels / short text on this page
Troubleshooting · Table B-5 · Symptom Action · Symptom Action
Page 191 of the Paradyne 3910 user manual — Overview
Page 191 · click to enlarge
Page 191

Pin Assignments

Overview C-1 EIA-232-D Pin Assignments C-2 VF Connector Pin Assignments C-3 Auxiliary Cables Not Supplied C-4

Overview

This appendix lists EIA-232-D and VF TELCO pin assignments and provides information about auxiliary cables which are not supplied.

C-1 3910-A2-GN32-30 November 1996

Page 192 of the Paradyne 3910 user manual — EIA-232-D Pin Assignments
Page 192 · click to enlarge
Page 192

EIA-232-D Pin Assignments

Table C-1 lists the EIA-232-D pin assignments for the modem.

Table C-1 EIA-232-D Pin Assignments

Paradyne 3910 — EIA-232-D Pin Assignments diagram (page 192)
Fig. 13 · EIA-232-D Pin Assignments

Pin Name EIA Circuit CCITT Signal Source Circuit Function

9 +12V — — — Reserved for test purposes (may be used to drive one RS-232 load)

10 –12V — — — Reserved for test purposes (may be used to drive one RS-232 load)

12 CT112 CI 112 DCE Data Signal Rate Select

13 — Reserved for future function

14 — Reserved for future function

16 — Reserved for future function

C-2 November 1996 3910-A2-GN32-30

Page 193 of the Paradyne 3910 user manual — VF Connector Pin Assignments
Page 193 · click to enlarge
Page 193

VF Connector Pin Assignments

Table C-2 lists the connector pin assignments for Model 3910 modular jacks as well as the pin assignments for the TELCO jacks. (See Figure C-1.)

Table C-2 VF Connector Pin Assignments

Paradyne 3910 — VF Connector Pin Assignments diagram (page 193)
Fig. 14 · VF Connector Pin Assignments

Type of Telco Jack Pin Leased Dial RJ11 JM8 6-Pin Leased

Paradyne 3910 — VF Connector Pin Assignments diagram (page 193)
Fig. 15 · VF Connector Pin Assignments

Figure C-1. VF Pin Orientation

C-3 3910-A2-GN32-30 November 1996

Pin Assignments

Page 194 of the Paradyne 3910 user manual — Auxiliary Cables Not Supplied
Page 194 · click to enlarge
Page 194

Auxiliary Cables Not Supplied

To add an external telephone to your modem, use an external “Y” cable to connect the phone line to both the modem and the telephone (Figure C-2).

Paradyne 3910 — Auxiliary Cables Not Supplied diagram (page 194)
Fig. 16 · Auxiliary Cables Not Supplied

Figure C-2. Wiring Diagram — “Y” Cable for External Telephone

C-4 November 1996 3910-A2-GN32-30

Page 195 of the Paradyne 3910 user manual — Pin Assignments
Page 195 · click to enlarge
Page 195

For 2-wire leased-line connections to a JM8 network interface, use an 8-position to 6-position crossover cable (Figure C-3) according to the following FCC requirements:

“The RJ series of jacks should not be used for connecting data equipment to nonswitched private line networks — specifically, the service equivalents of the pre-divestiture Series 3002 (Category II, Tariff #260) service. There is a substantial difference in transmit levels permitted in the private line service and those permitted in the public switched network. The industry standard is now an 8-pin keyed modular jack known as the USOC JM8 (Bellcore Technical Reference: TR-EOP-000242, Issue 1, released May 1985.) When ordering the installation of the USOC JM8, specify the appropriate wiring options:

  • 2-wir e operations
  • 4-wir e operations w/o TEK leads
  • 4-wir e operations with TEK leads

TEK leads are for loopback purposes.

A 50-pin version is being considered for multiple line connections.”

8-POSITION PLUG PIN NO.

6-POSITION PLUG PIN NO.

Figure C-3. Wiring Diagram — 8-Position to 6-Position Crossover Cable

C-5 3910-A2-GN32-30 November 1996

Pin Assignments

Page 196 of the Paradyne 3910 user manual — TXD
Page 196 · click to enlarge
Page 196

To connect a Model 3910 port to another modem’s EIA-232-D interface, use a 25-pin crossover cable (Figure C-4).

25-POSITION PLUG PIN NO.

25-POSITION PLUG PIN NO.

TXD

TXD

RXD

RXD

RTS

RTS

DSR

DSR

SG

SG

LSD

LSD

RXC

RXC

DTR

DTR

XTXC

XTXC

Figure C-4. Wiring Diagram — 25-Pin Crossover Cable

C-6 November 1996 3910-A2-GN32-30

Page 197 of the Paradyne 3910 user manual — NOTE
Page 197 · click to enlarge
Page 197

D

CCITT V.25bis Dialing Commands

and Responses

Overview D-1 Call Request Commands D-2 Call Request with Number Provided (CRN) D-2 Call Request with Stored Memory Address Provided (CRS) D-2 Call Response D-2 Call Failure Indication (CFI) D-2 Call Connecting (CNX) D-3 Delayed Call Indicator D-3 Call Answer Commands D-3 Incoming Call (INC) D-3 Disregard Incoming Call (DIC) D-3 Connect Incoming Call (CIC) D-4 Program Normal (PRN) D-4 Request List of Delayed Numbers (RLD) D-4 Request List of Forbidden Numbers (RLF) D-4 Request List of Stored Numbers (RLN) D-5 List Delayed Numbers Response (LSD) D-5 List Forbiddent Numbers Response (LSF) D-5 List Stored Number Response (LSN) D-5 Command Response D-6 Valid (VAL) D-6 Invalid (INV) D-6

Overview

This appendix describes V.25bis dialing commands and responses. CCITT V.25bis is an international dialing protocol that permits direct and stored number dialing using DTEs in either Asynchronous, Bisynchronous, or HDLC operating mode. The 391x Series modems support V.25bis request and answer commands. As commands are entered from the DTE, the 391x Series modems issue a response to the DTE which indicates if the call failed or connected, or if the command is valid or invalid.

The following sections discuss those V.25bis commands supported by the 391x Series modems and the response to those commands. Tables D-1 and D-2 list the V.25bis commands and response messages.

NOTE

The 391x Series modem must be configured for V.25bis dialing. Refer to DTE Dialer Type configuration option in Chapter 4, DCP Configuration.

D-1 3910-A2-GN32-30 November 1996

Page 198 of the Paradyne 3910 user manual — Call Failure Indication (CFI)
Page 198 · click to enlarge
Page 198

Call Request Commands

Call Request commands are issued from the DTE to the modem and are responsible for initiating dial calls. Call Request commands include Call Request with Number Provided (CRN) and Call Request with Stored Memory Address Provided (CRS).

Call Request with Number Provided (CRN)

The CRN command dials the telephone number entered from the DTE. CRN is similar to the ATD command.

The CRN command format is:

Where: n is the telephone number to be dialed.

Call Request with Stored Memory Address Provided (CRS)

The CRS command dials the telephone number stored in the request directory location. CRS is similar to the ATDS command.

The CRS command format is:

Where: x is directory location 1–24.

The modem responds to the command with either a VAL (valid) or INV (invalid) response followed by a call progress report such as connect (CNX) or failure (CFI).

Call Response

A Call Response indicates if the command was accepted by the modem. Call Response includes Call Failure Indication (CFI) and Call Connecting (CNX).

Call Failure Indication (CFI)

The CFI response is issued to the DTE if the modem fails a CRN or CRS command. CFI is similar to the AT result codes BUSY, NO ANSWER, NO CARRIER, NO DIALTONE, and ERROR.

The CFI response format is:

Wherexx is

ET is Engaged tone. NS is Number not stored. CB is Local DCE busy. RT is Time-out on ring tone. AB is Abort call on time-out. NT is Answer tone not detected. FC is Forbidden call.

D-2 November 1996 3910-A2-GN32-30

CRNn · CRSx · CFIxx

Page 199 of the Paradyne 3910 user manual — Disregard Incoming Call (DIC)
Page 199 · click to enlarge
Page 199

CCITT V.25bis Dialing Commands and Responses

ET is similar to the Call Failure Messages Busy Signal and Trunk Busy and the result code BUSY.

NS is similar to the Common Operational Message Invalid Number and the result code ERROR.

CB is similar to the Call Failure Messages Dial Line in Use and No Dial-Test and the result code ERROR.

RT is similar to the Call Failure Message No Answer Tone and the result code NO CARRIER.

AB is similar to the Call Failure Messages No Dial Tone and No Dial-DTR and the result code NO DIALTONE and ERROR.

NT is similar to the Call Failure Message No Quiet Answer and the result code NO ANSWER.

Call Connecting (CNX)

The CNX response informs the DTE that the modem has connected to the remote modem. CNX is similar to the AT result code CONNECT.

The CNX response format is CNX.

Delayed Call Indicator

The DLC response is issued to the DTE if the modem is not currently allowed to call the number. DLC is similar to the AT result code DELAYED.

The DLC response format is:

Where: n is the delay (in minutes) before the number can be called.

Call Answer Commands

Call Answer commands disable or enable the modem’s AutoAnswer function. These commands are issued from the DTE. Call Answer commands include Incoming Call (INC), Disregard Incoming Call (DIC) and Connect Incoming Call (CIC).

Incoming Call (INC)

The INC response informs the DTE that the modem has detected a ring tone. At this point, the DTE can issue the DIC command to disable the modem from answering the call. INC is similar to the AT result code RING.

Disregard Incoming Call (DIC)

The DIC command prevents the modem from answering an incoming call. This command is only valid once the DTE receives an incoming call (INC) response from the modem. A DIC must be issued within 5 seconds after receiving an INC.

The DIC command format is DIC.

If DIC is issued within 5 seconds, the modem sends the VAL response to the DTE. If DIC is issued after 5 seconds, INV is returned.

D-3 3910-A2-GN32-30 November 1996

DLCn

Page 200 of the Paradyne 3910 user manual — Request List of Forbidden Numbers (RLF)
Page 200 · click to enlarge
Page 200

Connect Incoming Call (CIC)

The CIC command forces the modem to cancel any DIC commands and answer an incoming call. This command is only valid when the DTE issues a DIC command. CIC must be issued within 10 seconds after sending a DIC. CIC is similar to the ATA command.

The CIC command format is CIC.

If CIC is issued within 10 seconds, the modem sends the VAL response to the DTE. If CIC is issued after 10 seconds, INV is returned.

Program Normal (PRN)

The Program Normal (PRN) command allows the DTE to enter and store a telephone number to a specific directory location. PRN is similar to the AT&Z command.

The PRN command format is:

PRNx;n

Where: x is the directory location 1–24; n is the telephone number.

Request List of Delayed Numbers (RLD)

The Request List of Delayed Numbers (RLD) command displays telephone numbers that are currently delayed as a result of failed call attempts. All the numbers currently delayed are displayed, irrespective of whether they belong to a directory location.

The RLD command format is RLD.

Request List of Forbidden Numbers (RLF)

The Request List of Forbidden Numbers (RLF) command displays telephone numbers that are forbidden as a result of failed call attempts. All the numbers forbidden are displayed, irrespective of whether they belong to a directory location.

The RLF command format is RLF.

D-4 November 1996 3910-A2-GN32-30

Page 201 of the Paradyne 3910 user manual — List Stored Numbers Response (LSN)
Page 201 · click to enlarge
Page 201

CCITT V.25bis Dialing Commands and Responses

Request List of Stored Numbers (RLN)

The Request List of Stored Numbers (RLN) command displays telephone numbers stored in the modem’s directory location. If the RLN command is entered without specifying a directory location, then all directory locations and telephone numbers appear. If a directory location is entered, then only that telephone number appears.

The RLN command format is:

RLN

which displays all directory locations,

Where: x is a directory location.

List Delayed Numbers Response (LSD)

LSD is a response to an LSD command issued by DTE.

LSDx;n;d

Where: x is a sequence number (not a directory location).

n is the telephone number.

d is the delay in minutes

List Forbidden Numbers Response (LSF)

The LSF response format is :

LSFx;n

Where: x is a sequence number (not a directory location).

n is the telephone number.

List Stored Numbers Response (LSN)

LSN is a response to an RLN command issued by the DTE. If a directory location is specified, then the telephone number for that location appears. If no directory location is specified, then all telephone numbers stored in memory appear.

The LSN response format is:

LSNx;n

D-5 3910-A2-GN32-30 November 1996

or · RLNx

Page 202 of the Paradyne 3910 user manual — Invalid (INV)
Page 202 · click to enlarge
Page 202

Command Response

A Command Response indicates that the command entered was a valid or invalid entry. Command Response includes Valid (VAL) and Invalid (INV).

Valid (VAL)

The VAL response indicates that the modem has accepted the V.25bis command issued by the DTE. VAL is similar to the AT result code OK.

Invalid (INV)

The INV response indicates that the modem has received an incorrect V.25bis command from the DTE. INV is similar to the AT result code ERROR.

The INV response format is:

Wherexx is

CU command unknown. MS message syntax error. PS parameter syntax error. PV parameter value error.

Table D-1 lists V.25bis commands supported by the 391x Series modems.

D-6 November 1996 3910-A2-GN32-30

INVxx

Page 203 of the Paradyne 3910 user manual — CCITT V.25bis Dialing Commands and Responses
Page 203 · click to enlarge
Page 203

CCITT V.25bis Dialing Commands and Responses

Table D-1 V.25bis Commands

Paradyne 3910 — CCITT V.25bis Dialing Commands and Responses diagram (page 203)
Fig. 17 · CCITT V.25bis Dialing Commands and Responses

D-7 3910-A2-GN32-30 November 1996

Page 204 of the Paradyne 3910 user manual — CCITT V.25bis Dialing Commands and Responses
Page 204 · click to enlarge
Page 204

Table D-2 lists V.25bis response messages supported by the 391x Series modems.

Table D-2 V.25bis Response Messages

V.25bis Command Description AT Command/ Result Code Equivalent

CFI Call Failure Indication BUSY, NO ANSWER, NO CARRIER, NO DIAL TONE, ERROR

CNX Call Connecting Indication CONNECT

VAL Valid Command OK

INV Invalid Command ERROR

D-8 November 1996 3910-A2-GN32-30

Call Response · Command Response

Page 205 of the Paradyne 3910 user manual — Overview
Page 205 · click to enlarge
Page 205

E

ASCII Character Table

Overview E-1

Overview

Table E-1 in this appendix provides the ASCII character table.

(1 of 4) ASCII Characters

Paradyne 3910 — Overview diagram (page 205)
Fig. 18 · Overview

E-1 3910-A2-GN32-30 November 1996

Table E-1

Page 206 of the Paradyne 3910 user manual — ASCII Character Table
Page 206 · click to enlarge
Page 206

(2 of 4) ASCII Characters

Paradyne 3910 — ASCII Character Table diagram (page 206)
Fig. 19 · ASCII Character Table

ASCII Value Key Control Character Decimal ASCII Value

E-2 November 1996 3910-A2-GN32-30

Table E-1

Page 207 of the Paradyne 3910 user manual — ASCII Character Table
Page 207 · click to enlarge
Page 207

(3 of 4) ASCII Characters

Paradyne 3910 — ASCII Character Table diagram (page 207)
Fig. 20 · ASCII Character Table

ASCII Value Key Control Character Decimal ASCII Value

E-3 3910-A2-GN32-30 November 1996

ASCII Character Table · Table E-1

Page 208 of the Paradyne 3910 user manual — ASCII Character Table
Page 208 · click to enlarge
Page 208

(4 of 4) ASCII Characters

Paradyne 3910 — ASCII Character Table diagram (page 208)
Fig. 21 · ASCII Character Table

ASCII Value Key Control Character Decimal ASCII Value

E-4 November 1996 3910-A2-GN32-30

Table E-1

Page 209 of the Paradyne 3910 user manual — Overview
Page 209 · click to enlarge
Page 209

F

Default Configuration Options

Overview F-1

Overview

Table F-1 in this appendix lists all default configuration options for the factory preset configurations. An N/A indicates that the value for this configuration option does not appear on the LCD when that factory default configuration is selected.

F-1 3910-A2-GN32-30 November 1996

Page 210 of the Paradyne 3910 user manual — N/A N/A N/A N/A N/A N/A
Page 210 · click to enlarge
Page 210

Factory Default Configuration Options

Sync Async Sync Async Async Sync

Async DTE Rate N/A 19,200 bps N/A 19,200 bps 19,200 bps N/A

Async # Data Bits

N/A 8 N/A 8 8 N/A

Async Parity Bit N/A None N/A None None N/A

Async # Stop Bits N/A 1 N/A 1 1 N/A

DTR Action1 Ignore Standard RS232

DSR Control Standard RS232

Forced On Standard RS232

Forced On Forced On Standard RS232

RTS Action Standard RS232

Ignore N/A (Trib) or Ignore (Control)

Ignore Ignore Standard RS232

RTS Antistream N/A N/A 10 sec (Trib) or N/A (Control)

N/A N/A N/A

CTS Control Standard RS232

Forced On Standard RS232

Forced On Wink When Disc

RTS/CTS Delay 0 msec 0 msec 0 msec 0 msec 0 msec 0 msec

LSD Control Standard RS232

Wink When Disc

TX Clock Source Internal N/A RXC Loop (Trib) or Internal (Control)

Backup TX Clock Source

N/A

XTXC Clamps TXC

N/A

CT111 Rate Control

Disable

DTE Rate = VF N/A Disable N/A Disable Disable N/A

Extend Main Channel

Disable

Upstream Port Port1

1 This configuration option is country dependent.

F-2 November 1996 3910-A2-GN32-30

Show 23 more labels / short text on this page
Table F-1 · (1 of 7) · Sync Leased · Async Leased · TMp Default Settings · Async Dial · UNIX Dial · Sync Dial · Configuration · Option · Default Settings · Default Settings · Default Settings · Default Settings · Default Settings · DTE Interface · Async/Sync Mode · Standard RS232 · Standard RS232 · Standard RS232 · Standard RS232 · Standard RS232 · N/A N/A Internal
Page 211 of the Paradyne 3910 user manual — Default Configuration Options
Page 211 · click to enlarge
Page 211

(2 of 7) Factory Default Configuration Options

Paradyne 3910 — Default Configuration Options diagram (page 211)
Fig. 22 · Default Configuration Options

DTE Dialer Type Disable AT Disable AT AT Disable

N/A 043 ASCII N/A 043 ASCII 043 ASCII N/A

N/A 1 sec N/A 1 sec 1 sec N/A

N/A 013 ASCII N/A 013 ASCII 013 ASCII N/A

N/A 008 ASCII N/A 008 ASCII 008 ASCII N/A

N/A 010 ASCII N/A 010 ASCII 010 ASCII N/A

Result Codes N/A Enable N/A Enable Enable In Originate

V.25bis Coding N/A

V.25bis Idle Fill N/A

F-3 3910-A2-GN32-30 November 1996

Default Configuration Options · Table F-1

Page 212 of the Paradyne 3910 user manual — Default Configuration Options
Page 212 · click to enlarge
Page 212

(3 of 7) Factory Default Configuration Options

Auto-Answer Ring Count1

1

Dialer Type Tone

Dial Tone Detect Enable

Blind Dial Pause N/A

Busy Tone Detect Enable

“,” Pause Time 2 sec 2 sec 2 sec 2 sec 2 sec 2 sec

No Answer Timeout1

45 sec 45 sec 45 sec 45 sec 45 sec 45 sec

Fast Disconnect Disable Enable

Line Current Disconnect1,2

Enable (>8 msec)

Enable (>8 msec)

Enable (>8 msec)

Enable (>8 msec)

Enable (>8 msec)

Enable (>8 msec)

Long Space Disconnect

Enable Disable

No Carrier Disconnect1

2 sec 2 sec 2 sec 2 sec 2 sec 2 sec

No Data Disconnect1

Disable

Auto Make Busy (3911 only)

Disable

Make Busy via DTR

Disable

Dial Line

Dial Line Rate 19200 (V32t) 19200 (V32t) 19200 (V32t) 19200 (V32t) 19200 (V32t) 19200 (V32t)

V.32bis Automode

Enable

V.32bis Autorate Enable

V.32bis Override Disable Disable N/A Disable Disable Disable

Dial Transmit Level1,3

Permissive (–9 dBm)

Permissive (–9 dBm)

Permissive (–9 dBm)

Permissive (–9 dBm)

Permissive (–9 dBm)

Permissive (–9 dBm)

V.22bis Guard Tone1

Disable

V.32bis Train Long

1 This configuration option is country dependent. 2 This configuration option does not appear on Models 3910-A1-401 and 3911-B1-001. 3 Except in North America, this configuration option is not changed by loading factory default configuration options.

F-4 November 1996 3910-A2-GN32-30

Show 15 more labels / short text on this page
Table F-1 · Sync Leased · Async Leased · TMp Default Settings · Async Dial · UNIX Dial · Sync Dial · Configuration · Default Settings · Default Settings · Default Settings · Default Settings · Default Settings · Option · Line Dialer
Page 213 of the Paradyne 3910 user manual — N/A N/A N/A N/A N/A N/A
Page 213 · click to enlarge
Page 213

(4 of 7) Factory Default Configuration Options

Leased Mode 4-wire LL Answer (Sync Leased Answ) or 4-wire LL Originate (Sync Leased Orig)

4-wire LL Answer (Async Leased Answ) or 4-wire LL Originate (Async Leased Orig)

4-wire LL Originate (TMp Tributary) or 4-wire LL Answer (TMp Control)

N/A N/A N/A

Leased Line Rate 19200 (V32t) 19200 (V32t) 19200 (TMp) (TMp Control) or 14400 (TMp) (TMp Tributary)

N/A N/A N/A

V.32bis Autorate Enable Enable N/A

V.32bis Override Disable Disable N/A

Leased Transmit Level1,3

0 dBm 0 dBm 0 dBm N/A N/A N/A

Auto Dial Backup Disable Disable Disable N/A N/A N/A

Auto Dial Standby

Disable Disable Disable N/A N/A N/A

Special Standby Disable Disable Disable N/A N/A N/A

Dial Standby Time

10 min 10 min 10 min N/A N/A N/A

Carrier On Level1 –43 dBm –43 dBm –26 dBm (TMp Control) or –43 dBm (TMp Tributary)

N/A N/A N/A

V.27bis Train N/A

V.29 Train on Data

N/A

V.29 Retrain N/A

V.29 Link Configuration

N/A

TMp Train Time N/A N/A 50 N/A N/A N/A

TMp Tx Preemphasis

N/A N/A Enable N/A N/A N/A

Lease Lookback Disable Disable Disable N/A N/A N/A

Dual Leased Line Disable Disable Disable N/A N/A N/A

Backup Line Check

Disable Disable Disable N/A N/A N/A

1 This configuration option is country dependent. 3 Except in North America, this configuration option is not changed by loading factory default configuration options.

F-5 3910-A2-GN32-30 November 1996

Show 16 more labels / short text on this page
Default Configuration Options · Table F-1 · Sync Leased · Async Leased · TMp Default Settings · Async Dial · UNIX Dial · Sync Dial · Configuration · Default Settings · Default Settings · Default Settings · Default Settings · Default Settings · Option · Leased Line
Page 214 of the Paradyne 3910 user manual — Default Configuration Options
Page 214 · click to enlarge
Page 214

(5 of 7) Factory Default Configuration Options

Paradyne 3910 — Default Configuration Options diagram (page 214)
Fig. 23 · Default Configuration Options

N/A (Direct) V.42/MNP or Buffer

N/A (Direct) V.42/MNP or Buffer

N/A Keep Data N/A Keep Data Keep Data N/A

N/A Data First N/A Data First Data First N/A

N/A 10 seconds N/A 10 seconds 10 seconds N/A

DTE RL (CT140) Disable

DTE LL (CT141) Disable

Test Timeout Disable

V.54 Address Disable

V.54 Device Type N/A

F-6 November 1996 3910-A2-GN32-30

Table F-1

Page 215 of the Paradyne 3910 user manual — N/A N/A N/A
Page 215 · click to enlarge
Page 215

(6 of 7) Factory Default Configuration Options

Straps When Disconnected

No Change No Change No Change No Change No Change No Change

Speaker Control On Until Carrier On Until Carrier On Until Carrier On Until Carrier On Until Carrier On Until Carrier

Speaker Volume Medium

Access from Remote2,4

Enable

Remote Access Password2,4

00000000

Directory Location No. 1 Callback

Disable

NMS Call Messages2,4

Call Connect & Progress

Call Connect & Progress

Call Connect & Progress

Call Connect & Progress

Call Connect & Progress

Call Connect & Progress

Network Position Identification

Tributary (3910) or Control (3911)

N/A Tributary (TMp Trib) or Control (TMp Control)

N/A N/A N/A

Network Management Address2,4

256

Modem(DC) Modem(DC) Modem(DC), NMS(CC) for TMp Control, or Disable for TMp Trib

0

2 This configuration option does not appear on Models 3910-A1-401 and 3911-B1-001. 4 This configuration option is not changed by loading factory default configuration options.

F-7 3910-A2-GN32-30 November 1996

Show 19 more labels / short text on this page
Default Configuration Options · Table F-1 · Sync Leased · Async Leased · TMp Default Settings · Async Dial · UNIX Dial · Sync Dial · Configuration · Default Settings · Default Settings · Default Settings · Default Settings · Default Settings · Option · Misc · Diagnostic Connection · Modem(DC) Modem(DC) Modem(DC) · Link Delay(seconds)
Page 216 of the Paradyne 3910 user manual — Default Configuration Options
Page 216 · click to enlarge
Page 216

(7 of 7) Factory Default Configuration Options

Entry Wait Time 20 sec 20 sec 20 sec 20 sec 20 sec 20 sec

VF Prompt Type 2nd Dial Tone 2nd Dial Tone 2nd Dial Tone 2nd Dial Tone 2nd Dial Tone 2nd Dial Tone

DTE Password Tries

1

DTE Password Termination Character

013 ASCII 013 ASCII 013 ASCII 013 ASCII 013 ASCII 013 ASCII

DTE Password Backspace Character

008 ASCII 008 ASCII 008 ASCII 008 ASCII 008 ASCII 008 ASCII

Get User ID Disable

000

Answer Security Mode2,4

No Answer Security

No Answer Security

No Answer Security

No Answer Security

No Answer Security

No Answer Security

Originate Security Mode2,4

No Originate Security

No Originate Security

No Originate Security

No Originate Security

No Originate Security

No Originate Security

2 This configuration option does not appear on Models 3910-A1-401 and 3911-B1-001. 4 This configuration option is not changed by loading factory default configuration options.

F-8 November 1996 3910-A2-GN32-30

Show 16 more labels / short text on this page
Table F-1 · Sync Leased · Async Leased · TMp Default Settings · Async Dial · UNIX Dial · Sync Dial · Configuration · Default Settings · Default Settings · Default Settings · Default Settings · Default Settings · Option · Security · NMS Reporting2,4
Page 217 of the Paradyne 3910 user manual — Overview
Page 217 · click to enlarge
Page 217

G

Sample Configuration

Overview G-1 Point-to-Point G-2 Configuration Options G-2 Cables G-2 Multipoint G-3 Configuration Options G-3 Cables G-3 Point-to-Point with Automatic Dial Backup G-4 Configuration Options G-4 Cables G-4 Point-to-Point with Network Management G-5 Configuration Options G-5 Cables G-5 Carrier with Network Management G-6 Configuration Options G-6 Cables G-6 Extended Multipoint G-7 Configuration Options G-8 Cables G-8 Extended Diagnostics G-9 Configuration Options G-9 Cables G-10 Adapter G-10

Overview

This appendix provides diagrams of sample configurations for the 391x Series modems. Following each diagram, the appropriate configuration options and cables are listed.

G-1 3910-A2-GN32-30 November 1996

Page 218 of the Paradyne 3910 user manual — Cables
Page 218 · click to enlarge
Page 218

Point-to-Point

Figure G-1 shows a sample configuration for point-to-point applications.

19200(V32t) 19200(V32t) TX TX

3910 A

DTE (Sync) 3910 B

Cable 1 Cable 1 Cable 2 Cable 2

Figure G-1. Sample Configuration — Point-to-Point

Configuration Options

3910 A Use Sync Leased (Answer) default configuration options.

3910 B Use Sync Leased (Originate) default configuration options.

Cables

Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1.

Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.

G-2 November 1996 3910-A2-GN32-30

Leased · DTE (Sync)

Page 219 of the Paradyne 3910 user manual — Cables
Page 219 · click to enlarge
Page 219

Multipoint

Figure G-2 shows a sample configuration for multipoint applications.

TMp control modems can accept mixed inbound rates from tributary modems. For example, one inbound link may be configured for 14.4 kbps while another link experiencing line impairments may be configured for 9.6 kbps. The following control/tributary rate combinations are allowed: control at 19.2 kbps, tributaries at 14.4 or 9.6 kbps; control at 14.4 kbps, tributaries at 14.4 or 9.6 kbps; control at 9.6 kbps, tributaries at 9.6 or 7.2 kbps; control at 7.2 kbps, tributaries at 7.2 or 4.8 kbps; control at 4.8 kbps, tributaries at 4.8 or 2.4 kbps; control at 2.4 kbps, tributaries at 2.4 kbps. Tributary rates will never exceed control rates. If tributary and control rates are equal, reducing the control rate will automatically reduce the tributary rate.

19200(TMp) 14400(TMp) TX TX

3910 A 3910 B

Cable 1 Cable 1 Cable 2 Cable 2

Cable 1 Cable 2

Figure G-2. Sample Configuration — Multipoint

Configuration Options

3910 A Use TMp (Control) default configuration options.

3910 B Use TMp (Trib) default configuration options.

3910 C Use TMp (Trib) default configuration options.

Cables

Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1.

Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.

G-3 3910-A2-GN32-30 November 1996

Show 6 more labels / short text on this page
Sample Configuration · Leased · DTE (Sync) · DTE (Sync) · 14400(TMp) TX · DTE (Sync)
Page 220 of the Paradyne 3910 user manual — Cables
Page 220 · click to enlarge
Page 220

Point-to-Point with Automatic Dial Backup

Figure G-3 shows a sample configuration for point-to-point applications with automatic dial backup.

Cable 3 Cable 3

19200(V32t) 19200(V32t) TX TX

DTE (Sync) 3910 A 3910 B

Cable 1 Cable 1 Cable 2 Cable 2

Figure G-3. Sample Configuration — Point-to-Point with Automatic Dial Backup

Configuration Options

3910 A Use Sync Leased (Answer) default configuration options with the following exception:

Auto Dial Back Set to Enable.

3910 B Use Sync Leased (Originate) default configuration options with the following exception:

Auto Dial Back Set to Enable.

Cables

Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1.

Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.

Cable 3 Use part number 125-0067-0031 (a 6-position, 4-wire modular cord that is supplied with the modem). Attach this to the connector labeled DIAL.

G-4 November 1996 3910-A2-GN32-30

Dial · DTE (Sync) · Leased

Page 221 of the Paradyne 3910 user manual — Cables
Page 221 · click to enlarge
Page 221

Point-to-Point with Network Management

Figure G-4 shows a sample configuration for point-to-point applications with network management.

19200(V32t) 19200(V32t) TX TX DTE (Sync)

3910 A

DTE (Sync) 3910 B NMS

Cable 1 Cable 1 Cable 2 Cable 2

IN

NMS (6700

or 6800) Adapter (002-0025-0031)

Figure G-4. Sample Configuration — Point-to-Point with Network Management

Configuration Options

3910 A Use Sync Leased (Answer) default configuration options.

3910 B Use Sync Leased (Originate) default configuration options.

Cables

Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1.

Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.

Cable 4 Use part number 835-1224-1011 (10 feet), part number 125-0040-0031 (12 feet), part number 835-1224-2511 (25 feet), part number 835-1224-5011 (50 feet), or an equivalent pin-to-pin 6-position, 6-wire modular cord. The maximum cable length is 50 feet.

G-5 3910-A2-GN32-30 November 1996

Show 4 more labels / short text on this page
Sample Configuration · Leased · 3600- F3- 300 Hubbing Device · Cable 4
Page 222 of the Paradyne 3910 user manual — Cables
Page 222 · click to enlarge
Page 222

Carrier with Network Management

Figure G-5 shows a sample configuration for COMSPHERE 3000 Series Carrier applications with network management.

19200(V32t) 19200(V32t) TX TX DTE (Sync)

Cable 1 Cable 1 Cable 2 Cable 2

IN

COMSPHERE 3000 Series Carrier

NMS (6700

or 6800) Adapter (002-0025-0031)

Figure G-5. Sample Configuration — Carrier with Network Management

Configuration Options

3911 Use Sync Leased (Answer) default configuration options.

3910 Use Sync Leased (Originate) default configuration options.

Cables

Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1.

Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.

Cable 4 Use part number 835-1224-1011 (10 feet), part number 125-0040-0031 (12 feet), part number 835-1224-2511 (25 feet), part number 835-1224-5011 (50 feet), or an equivalent pin-to-pin 6-position, 6-wire modular cord. The maximum cable length is 50 feet.

G-6 November 1996 3910-A2-GN32-30

Show 5 more labels / short text on this page
Leased · DTE (Sync) 3910 · SDU Circuit · Card · Cable 4
Page 223 of the Paradyne 3910 user manual — 3910 A 3910 B
Page 223 · click to enlarge
Page 223

Extended Multipoint

Figure G-6 shows a sample configuration for extended multipoint applications.

19200(V32t) 19200(V32t) TX TX

DTE (Sync) DTE (Sync) 3920 A 3920 B

1 2 3 4

1 2 3 4

Cable 2 Cable 2

4800(TMp) 4800(TMp) TX TX

3910 A 3910 B

Cable 1 Cable 2 Cable 2

Cable 1 Cable 2

Figure G-6. Sample Configuration — Extended Multipoint

G-7 3910-A2-GN32-30 November 1996

Show 16 more labels / short text on this page
Sample Configuration · Leased · DTE (Sync) · DTE (Sync) · Cable 1 · Cable 1 · Cable 1 · Cable 1 · Cable 1 · Cable 1 · Cable 1 · Cable 5 · Leased · DTE (Sync) · 4800(TMp) TX · DTE (Sync)
Page 224 of the Paradyne 3910 user manual — Cables
Page 224 · click to enlarge
Page 224

Configuration Options

3920 A Use Sync Leased (Answer) default configuration options with the following exception:

Rate at 19.2K Set ports 1, 2, 3, and 4 to 4800.

3920 B Use Sync Leased (Originate) default configuration options with the following exceptions:

TX Clock Source Set to RXC_Loop. Rate at 19.2K Set ports 1, 2, 3, and 4 to 4800. Port TXC Source Set port 4 to External.

3910 A Use TMp (Control) default configuration options with the following exceptions:

TX Clock Source Set to External. LeasedLine Rate Set to 4800(TMp).

3910 B Use TMp (Trib) default configuration options with the following exceptions:

TX Clock Source Set to RXC_Loop. LeasedLine Rate Set to 4800(TMp).

3910 C Use TMp (Trib) default configuration options with the following exceptions:

TX Clock Source Set to RXC_Loop. LeasedLine Rate Set to 4800(TMp).

Cables

Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1, 2, 3, or 4.

Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.

Cable 5 Use part number 818-2759-0111 or an equivalent customer-supplied, EIA-232-D/V.24 crossover cable with DB-25-P (plug) connectors on both ends to attach to the modems. (See Appendix C for pin assignments.)

G-8 November 1996 3910-A2-GN32-30

Page 225 of the Paradyne 3910 user manual — Configuration Options
Page 225 · click to enlarge
Page 225

Extended Diagnostics

Figure G-7 shows a sample configuration for extended diagnostics.

Paradyne 3910 — Extended Diagnostics diagram (page 225)
Fig. 24 · Extended Diagnostics

Figure G-7. Sample Configuration Extended Diagnostics

Configuration Options

3910 A Use Sync Leased (Answer) default configuration options with the following exception:

Network position Set to Control.

3910 B Use Sync Leased (Originate) default configuration options with the following exception:

TX Clock Source Set to External. Diagnostic Connection Set to Modem (DC).

3910 C Use Sync Leased (Answer) default configuration options with the following exceptions:

TX Clock Source Set to External. Extended Channel Set to Enable. Upstream Port # Set to Port 1. Diagnostic Connection Set to Modem (DC). Network Position Set to Continue.

G-9 3910-A2-GN32-30 November 1996

Sample Configuration

Page 226 of the Paradyne 3910 user manual — Adapter
Page 226 · click to enlarge
Page 226

3910 D,F,H

Use Sync Leased (Answer) default configuration options with the following exceptions:

TX Clock Source Set to RXC_Loop.

3910 E,G Use Sync Leased (Answer) default configuration options with the following exceptions:

Diagnostic Connection Set to Modem (DC). Network Position Set to Control.

Cables

Cable 1 Use a standard, customer-supplied, EIA-232-D/V.24 cable with a DB-25-P (plug) connector at one end to attach to the modem. Attach this to the connector labeled DTE1, 2, 3, or 4.

Cable 2 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord that is supplied with the modem). Attach this to the connector labeled LEASED.

Cable 5 Use part number 818-2759-0111 or an equivalent customer-supplied, EIA-232-D/V.24 crossover cable with DB-25-P (plug) connectors on both ends to attach to the modems. (See Appendix C for pin assignments.)

Cable 6 Use part number 125-0040-0031 (a 6-position, 6-wire modular cord). Attach this to the CCIN/DCOUT port of the 3600 Hubbing device.

Cable 7 Use part number 125-0053-1431 (an 8-position, 8-wire modular cord). Attach this to the CCIN/DCOUT port of one 3600 Hubbing device and to the CCOUT/DCIN port of the second device.

Adapter

871A Use part number 002-0026-0031 (Feature number 4400-F1-590).

G-10 November 1996 3910-A2-GN32-30

Page 227 of the Paradyne 3910 user manual — H
Page 227 · click to enlarge
Page 227

H

Equipment List

Equipment Feature/ Part Number

6-position, 4-wire modular cord, 7-foot length 125-0067-0031

8-position, 8-wire modular cord, 14-foot length 125-0053-1431

Universal Power Supply 327-0074-XXXX

3600 Hubbing Device 3600-F3-300

EIA-323-D/V.24 Crossover Cable 818-2759-0111

6 position, 6-wire modular cord 125-0040-0031

8 position, 8-wire modular cord 125-0053-1431

H-1 3910-A2-GN32-30 November 1996

Model 3910 3910-A1-XXX · Model 3911 3911-B1-XXX · 871A Adapter 002-0026-0031

Page 228 of the Paradyne 3910 user manual — Glossary
Page 228 · click to enlarge
Page 228

Glossary

Active (Operating) A configuration area containing configuration options currently in use by the modem. Anytime a power cycle occurs or a reset is performed or a save is issued using the DCP, this area is updated with the contents of Active (Saved).

Active (Saved) A nonvolatile configuration area containing the most recently saved configuration options.

ADp Advanced Diagnostic protocol. An enhanced diagnostic communication protocol used with the 6800 Series NMS and with certain DCP diagnostic functions.

analog loop See local analog loop.

analog signal A signal, such as a voice, that varies continuously.

Answer mode The modem is in a state where it is ready to receive an incoming call.

ASCII This code (American Standard Code for Information Interchange) is a 7-bit code which establishes compatibility between data services. ASCII is the standard for data transmission over telephone lines. The ASCII code consists of 32 control characters (nondisplayed) and 96 displayed characters. Refer to Appendix E.

A data transmission that is synchronized by a transmission start bit at the beginning of a character (five to eight bits) and one or more stop bits at the end.

AT command set A group of commands, issued from an asynchronous DTE, that allow control of the modem while in Command mode. All commands must begin with the characters AT and end with a carriage return.

AT prefix A prefix issued before every AT command (except A/ and +++) which identifies the DTE’s data rate, parity, and character length.

autobaud The modem automatically determines the asynchronous DTE data rate when using AT commands.

automatic answer A capability to respond to a call received over a dial line.

GL-1 3910-A2-GN32-30 November 1996

asynchronous transmission

Page 229 of the Paradyne 3910 user manual — Glossary
Page 229 · click to enlarge
Page 229

automatic dial backup When leased-line operation fails, this function forces the modem to dial the telephone number stored in directory location 1.

automatic dial standby When operating in Dial Backup mode, this function forces the modem to periodically check the quality of the leased line. If the leased line is found to be at normal operating condition, the modem disconnects from the dial network and continues normal operation over the leased-line network.

automatic rate control Modems adjust their signaling rate based on current line conditions.

backbone network The primary route from a control modem to its first tributary when the communications network contains extended control modems.

backplane A common bus at the rear of the COMSPHERE 3000 Series Carrier connecting each circuit card slot to the SDCP and/or SDU. It also distributes low-voltage ac power to each slot.

baud A unit of signaling speed that is equal to the number of symbols per second. This is not necessarily the same as bits per second, although the terms are frequently interchanged.

Bisync Binary Synchronous Communications. An IBM communications protocol that has become an industry standard. It uses a defined set of control characters and control-character sequences for synchronized transmission of binary-coded data between stations in a data communications system.

bit A contraction of binary digit. A bit, which is the smallest unit of information, represents the choice between a one or a zero (sometimes called mark or space).

bps Bits per second. Indicates the speed at which bits are transmitted across a data connection.

broadcast A method of transmission. The simultaneous transmission to two or more communicating devices.

buffer A storage device used to compensate for differences in the data flow rate when transmitting data from one device to another.

byte A sequence of successive bits (usually eight) handled as a unit in data transmission.

carrier The rack mounting that contains 17 slots: 1 control slot for an SDU and 16 modem slots. See data carrier.

carrier-mount A modem that is designed for installation in a COMSPHERE 3000 Series Carrier and used at central-site operations.

GL-2 November 1996 3910-A2-GN32-30

Page 230 of the Paradyne 3910 user manual — Glossary
Page 230 · click to enlarge
Page 230

CCITT An advisory committee (Consultative Committee on International Telephone and Telegraph) established by the United Nations to recommend communications standards and policies.

CCITT V.22 A standard for modems operating full-duplex over dial networks at 1200 bps.

CCITT V.22bis A standard for modems operating full-duplex over leased lines or dial networks at 2400 bps.

CCITT V.27bis A standard for modems operating over leased lines at 2400 or 4800 bps.

CCITT V.29 A standard for modems operating over leased lines at 4800, 7200, or 9600 bps.

CCITT V.32 A standard for modems operating full-duplex with asynchronous or synchronous data over leased lines or dial networks at 4800 or 9600 bps.

CCITT V.32bis A standard for modems operating full-duplex with asynchronous or synchronous data over leased lines or dial networks at 4800, 7200, 9600, 12000, or 14400 bps.

CCITT V.42 CCITT standard for error control protocol.

CCITT V.42bis CCITT standard for data compression.

CCITT V.54 CCITT standard for local and remote diagnostic loopback tests.

channel A path for electrical transmission between two or more points. Also called a circuit, line, link, path, or facility.

character A letter, figure, number, punctuation, or other symbol.

character echo A way to check the accuracy of data transmission by sending to the monitor (displaying) all the characters being transmitted.

circuit pack lock A screw lock tab installed over a circuit card’s latch release tab to prevent the unit from being removed without a tool. It is used on SDUs, modems, and filler panels.

Command mode One of two modem operating modes. When in Command mode, the modem accepts commands instead of transmitting or receiving data.

configuration area One of five areas within the Configure branch containing modem settings. Configuration areas include Active (Operating), Active (Saved), Customer 1, Customer 2, and Factory.

configuration option Modem software that sets specific operating parameters for the modem. Sometimes referred to as straps.

connector An outlet on equipment and cables that provides a connection.

GL-3 3910-A2-GN32-30 November 1996

Glossary

Page 231 of the Paradyne 3910 user manual — Glossary
Page 231 · click to enlarge
Page 231

constant carrier mode The modem transmits a carrier signal constantly, regardless of RTS.

Control Channel (CC) The diagnostic interface between an NMS and a network device.

control modem A control modem polls downstream tributary modems across the analog channel.

controlled carrier mode The modem’s transmitter turns on and off in response to RTS. This mode is used by multipoint tributary modems.

Customer 1 A user-defined configuration area containing customized configuration options for a specific application.

Customer 2 A user-defined configuration area containing customized configuration options for a specific application.

data carrier A continuous frequency signal that can be modulated by another signal that contains information to be transmitted.

data compression The elimination of empty fields, redundancies, and gaps in order to reduce storage capacity needs and the amount of data to be transmitted. Anything that is eliminated is restored after the data is received.

Data mode One of two modem operating modes. When in Data mode, the modem transmits and receives data instead of accepting commands.

DB-25 connector A 25-pin connector that is used to connect a cable which enables communication between two devices.

dBm A decibel referenced to one milliwatt. This unit measures relative signal power.

DCE The equipment (Data Communications Equipment or Data Circuit Terminating Equipment) that provides the functions required to establish, maintain, and end a connection. This equipment also provides the signal conversion required for communication between the DTE and the telephone line.

DCP Diagnostic Control Panel. The face of the modem that continuously provides status information about the modem’s operation and allows an operator to manage its operation. This is a generic term used for both the standalone and carrier-mounted models. See SDCP.

demodulation The process of recovering data from a modulated carrier wave.

DevHS Device Health and Status. A detailed account of device alarms.

Diagnostic Channel (DC) The diagnostic interface between two network devices, used to extend the NMS diagnostics to downstream devices.

GL-4 November 1996 3910-A2-GN32-30

Page 232 of the Paradyne 3910 user manual — Glossary
Page 232 · click to enlarge
Page 232

dial command modifiers A modifier used in the dial string that instructs the modem how to process a dialed telephone number.

dial line A communications circuit that is established by a switched circuit connection in the dial network.

dial network See PSTN.

Dial Standby A function available when the modem is operating in Dial Backup mode, allowing the modem to switch back to lease-line operation while still maintaining the dial-line connection.

dial string A series of characters that consists of numbers and modifiers used to dial a telephone number.

digital signal A discrete signal. Compare with analog signal.

directory location Nonvolatile memory that stores up to ten telephone numbers. Each directory location can have up to 40 characters entered.

DOC Canadian Department of Communication.

download A process that transfers modem firmware from a locally attached PC to a modem or allows the cloning of firmware from a local modem to a remote modem.

downstream modem A device connected “farther” from the host computer.

DTE The equipment (Data Terminal Equipment), such as a computer or terminal, that provides data in the form of digital signals.

edit area A temporary work area used to view and change configuration options from the DCP. The edit area can be loaded from one of five configuration option areas, Active (Operating), Active (Saved), Customer 1, Customer 2, or Factory.

EIA Electronic Industries Association. This organization provides standards for the data communications industry.

EIA-232-D An Electronic Industries Association’s standard defining the 25-position interface between data terminal equipment and data communications equipment.

EIA RS-366-A An Electronic Industries Association’s standard defining the 25-position interface between data terminal equipment and data communications automatic calling equipment.

error control An algorithm used to correct data transmission errors.

escape sequence Default setting is +++. This sequence lets you switch your modem from Data mode to Command mode.

extended circuit See extended network.

GL-5 3910-A2-GN32-30 November 1996

Glossary

Page 233 of the Paradyne 3910 user manual — Glossary
Page 233 · click to enlarge
Page 233

extended network The extension of a circuit where the tributary DCE is connected to a downstream (extended) control DCE.

extended result codes An asynchronous message (in either numbers or words) that includes VF data rate and error control information the modem sends to the DTE after executing or trying to execute a command.

fallback Retraining at a lower rate or speed.

FCC Federal Communications Commission. Board of Commissioners that regulates all interstate and foreign electrical communication systems that originate from the United States.

Forward Error Correction (FEC)

A method of error control for data transmission where the receiving device can detect and correct a character or block of code containing a predetermined number of erroneous bits.

A communications computer associated with a host computer that manages the routing of data through the network.

full-duplex Simultaneous, two-way communications.

function key Any one of three keys on the DCP that allows you to select or increment an LCD entry. Function keys are labeled F1, F2, and F3.

half-duplex Two-way data communications allowed in only one direction at a time.

handshaking The exchange of predetermined codes and signals (tones) to establish a connection between two modems.

HDLC High-Level Data Link Control. A communications protocol defined by the International Standards Organization (ISO).

host A computer attached to a network that shares its information and devices with the rest of the network.

Hz A unit of frequency (Hertz) that equals one cycle per second.

idle A state in which the modem’s operating parameters can be modified or commands can be issued to the modem using either AT commands or the DCP.

JM8 A jack used for leased-line networks. Pins 1 and 2 are the transmit pair and Pins 7 and 8 are the receive pair.

keypad A set of seven keys surrounding the DCP’s LCD. These keys are used to select configuration options and to maneuver through the DCP menu.

LCD Liquid Crystal Display. A thin sandwich of two sealed glass plates containing liquid crystal material. When voltage is applied, the amount of light able to pass through the glass plates is altered so that messages may be “written” on the display.

GL-6 November 1996 3910-A2-GN32-30

Front-End Processor (FEP)

Page 234 of the Paradyne 3910 user manual — Glossary
Page 234 · click to enlarge
Page 234

leased line A private telephone line connection exclusively for the user. No dialing is necessary.

LED Light Emitting Diode. A light or status indicator on the DCP that glows in response to the presence of a certain condition (e.g., an alarm).

Link The physical connection between one location and another used for data transmission. See Channel.

local analog loopback The modem’s transmit VF signal is looped to its receiver.

long space disconnect A disconnect can occur if the modem receives an extended space from a remote modem; for example, when a remote modem is commanded to disconnect, it transmits a continuous space to the local modem before disconnecting.

loopback test Any test that verifies a device’s integrity by connecting the device’s output to the device’s input, then checking the received signal for errors.

menu tree The structure containing the menu hierarchy starting at a Top-Level menu and extending down to various modem functions.

mixed inbound rates In a multipoint network, several different data rates from tributary modems’ transmitters communicating with one control modem.

MNP This protocol (Microcom Networking Protocol) detects and corrects data errors caused by telephone line noise and signal distortion. MNP5 includes data compression.

modem (Modulator/DEModulator). A device that transforms signals from digital to analog form and vice versa.

modulation The process of varying some characteristics (usually amplitude, frequency, and/or phase) of a carrier wave to form data transmissions.

multiplexer (mux) A device that enables the simultaneous transmission of multiple independent data streams into a single high-speed data stream.

multipoint line A circuit connecting one control modem with one or more tributary modems.

network A communications circuit.

The customer-assigned diagnostic address of a modem.

NIM Network Interface Module. The interface provided, up to two per carrier, for the public switched telephone network (PSTN).

non-linear distortion VF line distortion which is usually associated with pulse-code modulation (PCM) compandor noise on the phone line.

GL-7 3910-A2-GN32-30 November 1996

Glossary · network management address

Page 235 of the Paradyne 3910 user manual — Glossary
Page 235 · click to enlarge
Page 235

NMS Network Management System. A set of diagnostic and configuration management tools for a data communication network, consisting of software programs and dedicated computer hardware.

off-hook A telephone or modem is being used.

on-hook A telephone or modem is not being used.

Originate mode The modem is in a state where it is ready to transmit a call. In a dial network, it is the modem that makes the call. In a leased-line network, it is one of two sides of the network that is selected to be the originating modem.

parity A way of checking data accuracy by counting the number of bits that have a value of one.

PBX Telephone switching equipment (Private Branch Exchange) dedicated to one customer. A PBX connects private telephones to each other and to the public dial network.

permissive interface A dial modem operating mode characterized by a fixed output power level of –9 dBm.

phase jitter A rapid or repeated shifting of the relative phase of a signal resulting in unwanted distortion.

physical address The diagnostic address of a control modem derived from its location in the carrier: its carrier and slot number.

point-to-point line A line or circuit connecting two stations.

poll list A list containing the network management addresses of downstream modems.

power-up self-test A test that checks most hardware components when the modem is powered-on.

product code A three-digit code indicating the modem’s highest VF data rate.

protocol The rules for timing, format, error control, and flow control during data transmission.

PSTN Public Switched Telephone Network. A network shared among many users who can use telephones to establish connections between two points. Also known as dial network.

An informative display screen available from the modem’s Top-Level display. It provides such information as network position (control or tributary), network management address, DTE mode (Asynchronous or Synchronous), Line mode (Leased Answer, Leased Originate, or Dial), and the modulation scheme used by the modem.

GL-8 November 1996 3910-A2-GN32-30

Quick Configuration display

Page 236 of the Paradyne 3910 user manual — Glossary
Page 236 · click to enlarge
Page 236

register A part of the modem’s memory that contains values that determine the modem’s operating characteristics.

Remote A branch of the Top-Level menu that permits access to the DCP of another modem.

remote loopback A test that sends a signal to the remote modem to test the local modem, the remote modem, and the circuit between them.

result code An asynchronous message (in either numbers or words) that the modem sends to the DTE after executing or trying to execute a command.

Return to Dial A function available when in Dial Backup mode that allows the modem to switch to dial-line operation when currently on leased lines.

RJ11 A type of 6-position jack normally used with permissive dial networks and telephone sets.

RJ21 A type of 50-position jack normally used with permissive dial networks providing the appropriate conductors for up to eight telephone lines.

SDCP Shared Diagnostic Control Panel. An optional user interface that attaches to the front of a COMSPHERE 3000 Series Carrier. Its functionality is very similar to that of the DCP. Installed in one COMSPHERE 3000 Series Carrier, it controls and monitors modems in all the carriers in the cabinet. A single SDCP can control up to 8 carriers, with a total of 128 modems.

SDU Shared Diagnostic Unit. A circuit card that plugs into a dedicated slot in the COMSPHERE 3000 Series Carrier to provide the SDCP and network management interfaces to the modems in the carrier. It translates the network management protocol to the devices in the carrier and routes incoming messages to the appropriate slots.

secondary channel A data transmission channel with a lower signaling rate than the primary channel. It is mostly used for modem diagnostics.

Select key An SDCP key that allows the selection of a specific card slot in the COMSPHERE 3000 Series Carrier.

serial transmission A way of transmitting data in which bits are sent sequentially one at a time.

S-Registers Registers that contain information affecting the modem parameters. All S-Registers must be preceded by the AT prefix.

SubHS Sub-Network Health and Status. A display of alarm occurrences in downstream modems.

synchronous transmission Data transmission that is synchronized by timing signals. Characters are sent at a fixed rate. This type of transmission is more efficient than asynchronous transmission.

GL-9 3910-A2-GN32-30 November 1996

Glossary

Page 237 of the Paradyne 3910 user manual — Glossary
Page 237 · click to enlarge
Page 237

Time Division Multiplexer (TDM)

A device that enables the simultaneous transmission of multiple independent data streams into a single high-speed data stream by simultaneously sampling the independent data streams and combining these samples to form the high-speed stream.

TMp Trellis Multipoint. Paradyne’s proprietary high speed, fast poll multipoint modulation scheme.

Top-Level menu The very top of the menu tree that displays modem status and all Top-Level menu branches.

training A process where two modems try to establish a connection over the VF line.

trellis-coded modulation A modulation scheme developed by Paradyne which uses Forward Error Correction for multipoint and high-speed point-to-point applications.

tributary modem Tributary modems in a network receive data from the control modem, as well as from the network management system in the network.

UL Underwriter’s Laboratories, Inc.

UNIX Dial A factory preset configuration area containing the configuration options most often used in a UNIX dial network.

USOC Universal Service Ordering Codes.

upstream modem A device connected “closer” to the host computer.

V.32 terbo A modulation that adds the 19,200 bps and 16,800 bps data rates to the V.32bis data rates. It is a Paradyne proprietary modulation, not a CCITT standard.

VF Voice Frequency. The part of the audio frequency range used to transmit voice sound (usually 300 Hz to 3400 Hz). This band is used by the modem for its modulated signal.

XOFF A character that tells the DTE or modem to stop transmitting data.

XON A character that tells the DTE or modem to start or resume transmitting data.

GL-10 November 1996 3910-A2-GN32-30

Page 239 of the Paradyne 3910 user manual — D
Page 239 · click to enlarge
Page 239

cables, 2-4, 2-5, H-1 Call Setup branch, 3-8, 3-54–3-62 Canadian government requirements, 1-7 Clone Remote, 3-36–3-42 compatibility, 1-8 COMSPHERE 3000 Series Carrier

Model 3911 installation and removal, 2-9–2-12 network interface module (NIM), 2-2, 3-35 service line, 3-35 configuration options

defaults, 2-6–2-8, 4-1, F-2–F-7 quick display, 3-14 tables

Dial Line, 4-30–4-32 DTE Dialer, 4-19–4-24 DTE Interface, 4-9–4-19 Leased Line, 4-33–4-38 Line Dialer, 4-25–4-29 Misc, 4-48–4-51 Security, 6-13–6-16 Test, 4-46–4-47 V.42/MNP/Buffer, 4-38–4-46 Configure branch, 3-8, 3-25, 4-1, 4-4–4-8 Control branch, 3-8, 3-30–3-45 Customer 1 configurations, 4-1 Customer 2 configurations, 4-1 Customer Support, 1-6

D

data compression, 4-40 data rates. See rates DATAKIT, 4-16, 4-20 default configuration options, 2-6–2-8, 4-1, F-2–F-7 diagnostic control panel (DCP)

configurations. See configuration options description, 1-3–1-5, 3-2–3-3 menu tree, 3-8, A-1–A-3 messages, 3-9–3-14, 3-23–3-24 operation, 2-6–2-7, 3-6–3-8, 4-5–4-8, 6-7 status indicators (LEDs), 3-4–3-6 diagnostic tests. See Test branch dial

access security. See Security answering a call

auto-answer, 3-63, 4-25 manual answer, 3-57, 3-64, 4-25 backup, 2-4, 3-35, 3-54, 3-57–3-59, B-2 command modifiers, 3-61, 5-5, 5-6 DCP controlled, 3-54–3-62 manual dial. See Talk/Data network connection, 2-4, B-4–B-5 stored telephone number, 3-59–3-62, 5-12

Index-2 November 1996 3910-A2-GN32-30

Page 240 of the Paradyne 3910 user manual — G
Page 240 · click to enlarge
Page 240

Dial Line configuration options group, 4-30–4-32 digital loopback, 3-49–3-51 dimensions, 1-9 directory, telephone number, 3-59–3-62 disconnecting a call, 3-56–3-57 Download Software, 3-35–3-42 DTE

connection, 2-4, B-3 status, 3-4–3-6, 3-21 DTE Dialer configuration options group, 4-19–4-24 DTE Interface configuration options group, 4-9–4-19 dual leased-line operation. See backup, leased

E

EIA LEDs, 3-33 EIA-232-D

cable connection, 2-4, B-3 pin assignments, C-2 status, 3-4–3-6, 3-21 end-to-end pattern test, 3-52 environment, 1-9 equipment

customer supplied, 2-2 list, 2-1–2-2, H-1 return, 1-6 error control, 4-39 escape character ( + + + ), 4-21, 5-2, 5-15

F

faceplate, 1-4, 3-3 factory default configurations, 2-6–2-8, 4-1, F-2–F-7 features, 1-1–1-2 firmware part number (FPt #), 3-20 firmware revision level (FRev), 3-20 firmware upgrades/download, 3-35–3-42 flow control, 4-42, 4-43 front panel. See diagnostic control panel function keys, 3-6, 3-8, 4-8

G

Canada, 1-7 United States, 1-5–1-6

Index-3 3910-A2-GN32-30 November 1996

Index · government requirements

Page 241 of the Paradyne 3910 user manual — K
Page 241 · click to enlarge
Page 241

H

handshaking sequence, 3-63, 3-64 hang up, 3-56–3-57 hardware part number (HPt #), 3-20 HDLC, 4-20, D-1 Health and Status definitions, 3-23–3-24

definitions, 3-7 status (LEDs), 3-4–3-6 installation

Model 3910, 2-2–2-12 Model 3911, 2-9–2-11

K

LCD (liquid crystal display)

description, 3-2, 3-6–3-7 menu structure, 3-8 messages, 3-9–3-14, 3-23–3-24 leased backup operation. See backup, leased Leased Line configuration options group, 4-33–4-38 leased-line connection, 2-4 leased-line operation, 4-33–4-38, B-2 LEDs, status indicators, 3-4–3-6 line connection

dial, 2-4 leased, 2-4 Line Dialer configuration options group, 4-25–4-29 Load Number (LN), 1-7 loopback

local analog, 3-48–3-49 local digital, 3-50–3-51 remote digital, 3-49–3-50

Index-4 November 1996 3910-A2-GN32-30

Identity, 3-20 indicators · keypad, 3-7–3-8

Page 242 of the Paradyne 3910 user manual — P
Page 242 · click to enlarge
Page 242

M

Make Busy, 3-34 manual dial. See Talk/Data menu

quick configuration display, 3-14 tree, A-1–A-3 messages

LCD, 3-9–3-14, 3-23–3-24 result codes, 5-3–5-4 Misc configuration options group, 4-48–4-51 mixed inbound rates, 1-2, 4-34, G-3 model number (Mod #), 3-20 modifiers, dial string, 3-61, 5-5, 5-6 modulation schemes

dial line, 1-8, 4-30, 5-17 leased line, 1-8, 4-34, 5-18 multipoint operation, 1-2

N

network interface module (NIM), 2-2, 3-35 network management address, 3-26, 4-50 network management system connection, 2-5

O

AT commands, 5-1 Talk/Data, 3-8, 3-62–3-64 operational messages, 3-9–3-14 Options, Status branch, 3-23–3-24 options, strap. See configuration options originate access security, 6-2, 6-16–6-17

P

part numbers, 3-20, H-1 passwords

administrative, 6-5–6-6 remote access, 3-65, 3-67, 3-68, 4-5–4-8, 4-49 security, 6-2–6-4, 6-16–6-17 pattern test, 3-51–3-53 phone. See telephone, external phone numbers. See telephone numbers pin assignments, C-2 PList (Poll List) branch, 3-8, 3-25–3-30 power consumption, 1-9 power supply connection, 2-5 power-up self-test, 2-5 public switched telephone network (PSTN). See dial

Index-5 3910-A2-GN32-30 November 1996

Index · structure, 3-8 · operating modes

Page 243 of the Paradyne 3910 user manual — S
Page 243 · click to enlarge
Page 243

R

automatic control, 4-35 dial line, 1-10, 4-30, 5-17 leased line, 1-10, 4-34, 5-18 rear connector plate, 1-4 rear panel connectors, 1-4–1-5, 2-3, C-2 Record, Status branch, 3-24–3-25 Remote

access password, 3-65, 3-67, 3-68, 4-5–4-8, 4-49 branch, 3-8, 3-65–3-68 remote digital loopback test, 3-49–3-50 requirements

ac power, 1-9 government, 1-5–1-7 reset control, 3-31–3-32 result codes

enable/disable, 4-22, 5-7 extended, 4-23, 5-8 list, 5-3–5-4 numeric or word, 4-23, 5-7 Return Material Authorization, 1-6 ringer equivalence number (REN), 1-5 RMA number, 1-6

S

S-Register list, 5-14–5-28 Security

access messages, 3-13 branch, 3-8, 6-4–6-13 configuration options, 6-13–6-16 database tables, 6-2, 6-3, 6-18–6-19 passwords, 6-2–6-4, 6-16–6-17 Select key, 2-10, 2-11, 3-7, 3-8 self-test, 3-47–3-48 self-test, 2-5 serial number (Ser #), 3-20 service line, 3-35 shared diagnostic control panel (SDCP), 1-5, 3-3 soft straps. See configuration options software download, 3-35–3-42 speaker, 1-3, 3-31 specifications, technical, 1-8–1-10 Status branch, 3-8, 3-15–3-25 status indicators

definitions, 3-7 LEDs, 3-4–3-6 straps. See configuration options SubHS (Sub-Network Health and Status) branch, 3-8, 3-53–3-54 synchronous operation, 2-6, 4-1, 4-10

Index-6 November 1996 3910-A2-GN32-30

rates

Page 244 of the Paradyne 3910 user manual — W
Page 244 · click to enlarge
Page 244

T

branch, 3-8, 3-62–3-64 telephone, external, 3-62, C-4 technical specifications, 1-8–1-10 telephone, external, 3-62, C-4 telephone numbers

display, 3-56 storage, 3-60 Test branch, 3-8, 3-46–3-53

Abort, 3-46–3-47 Local Analog Loopback, 3-48–3-49 Local Digital Loopback, 3-50–3-51 Pattern, 3-51–3-53 Remote Digital Loopback, 3-49–3-50 Self, 3-47–3-48 Test configuration options group, 4-46–4-47 TMP default configurations. See default configuration options top-level menu messages, 3-9–3-14 Trellis Multipoint (TMp), 3-9, 3-10, 3-14, 3-15, 3-19, 3-20, 3-38, 3-66, 3-67 Troubleshooting, B-1–B-5

U

United States government requirements, 1-5–1-6 UNIX dial, 2-6, 4-1, 4-10

V.25bis dialing commands and response, D-1–D-8 V.42bis data compression, 4-40 V.42 error control, 4-39 V.42/MNP/Buffer configuration options group, 4-38–4-46 VF

connection, 2-4, B-4–B-5 interface requirements, 1-9 pin assignments, C-3 status, 3-19–3-20 VF Thresholds Update, 3-42–3-45

W

Index-7 3910-A2-GN32-30 November 1996

Index · Talk/Data · weight, 1-9

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
The modem did not pass the power-up self-test.Contact your service representative. p.186
The power LED does not light or the LCD does not display information.Make sure the modem’s ON/OFF switch is in the ON position. Make sure the power supply is connected to the dc power receptacle on the modem. If the Power LED and/or LCD do not operate, contact your service representative. p.186
A problem is suspected after the power-up self-test.Perform a self-test via the modem’s DCP or type AT&T9 if using AT commands. Perform a local analog loopback with a Pattern test. If the modem consistently registers errors, contact your service representative. If the modem passes the above tests and a problem still exists, then the problem is probably not with your modem. p.186
The modems do not train-up on leased lines.Verify that the correct cabling is used for your application. Refer to Chapter 2, Modem Installation. Verify that one modem is configured for Answer mode and the other is configured for Originate mode. (For TMp operation one modem must be configured as a control modem and the other as a tributary modem.) Verify that both modems are using the same modulation scheme. Verify that both modems are configured for the appropriate leased-line mode. For example, if you have a 4-wire leased line, then the modems must be configured for 4-wire operation. p.187
The dial backup line is present, but the modems cannot connect.Verify that the correct telephone number for the remote modem is stored in directory location 1. Verify that both modems have the Auto Dial Backup configuration option set to Enable. Refer to Leased Line in Chapter 4. Call the answering modem with a handset and verify that the modem’s answer tone is transmitted. p.187
The modem does not switch back to leased-line operation.Verify that the Auto Dial Standby configuration option is enabled. Refer to Leased Line in Chapter 4. p.187
The modem does not accept or echo back AT commands.Verify that the cable between the Async port of the DTE and the modem is a standard RS-232 cable. (Null modem cables, also known as crossover cables, do not work in this application.) Verify that the Command Character Echo configuration option is enabled. Refer to DTE Dialer in Chapter 4. Verify that the DTE Dialer Type configuration option is set to AT. Refer to DTE Dialer in Chapter 4. Verify that the Result Codes configuration option is enabled. Refer to DTE Dialer in Chapter 4. Reload the Async Dial factory configuration area to guarantee that all configuration options are returned to their proper setting. Make sure that all AT commands are terminated with a carriage return. Verify that the Carriage Return Character configuration option matches what is used by the DTE. Refer to DTE Dialer in Chapter 4. Verify that the DTE has a valid character format. Valid format consists of 8 data bits with no parity or 7 data bits with even, odd, mark or space parity. Verify that the DTE’s data rate is supported by the modem. Refer to the Async DTE Rate configuration option in the DTE Interface section of Chapter 4. If using a PC, verify that the modem is attached to the correct communications port. p.188
The modem does not receive a dial tone.Attach a telephone directly to the telephone line to verify that a dial tone exists. Make sure the VF line is connected to the modem’s rear jack labeled DIAL. p.189
The modem does not go off-hook and answer an incoming call.Verify that the Auto Answer Ring Count configuration option is set to a value other than 0 (disable). Refer to Line Dialer in Chapter 4. Verify that the DTE is providing DTR to the modem. If the DTE does not provide DTR to the modem, verify that the modem’s DTR Action configuration option is set for Ignore. Refer to DTE Interface in Chapter 4. Verify that all cables are attached to the correct connectors on the rear of the modem. p.189
The modem goes off-hook, answers, but does not connect.Perform a Local Analog Loopback test and verify that data entered at the DTE is echoed back to the DTE. Verify that the originating modem is compatible with your receiving modem. Verify that the originating modem recognizes your modem’s answer tone. Verify that the originating modem supports your modem’s modulation schemes. The 391x Series modem recognizes CCITT V.32bis, V.32, V.22bis, V.22, V.21, Bell 212A, and Bell 103J. The 391x Series modem does not support other vendors’ proprietary modulation schemes. Force your modem to operate at the same modulation scheme as the originating modem to see if they connect. p.189
The Originate Mode does not function properly.Verify that the modem’s DTE Dialer Type configuration option is set to the correct setting: either AT, DTR Dialing, V.25bis Async, V.25bis Bisync, or V.25bis HDLC. Refer to DTE Dialer in Chapter 4. p.189
The modem does not go off-hook and begin dialing.If using AT Dialing, refer to the Table B-2, Modem—DTE Connection. If using DTR Dialing, verify the telephone number stored in directory location 1, and verify that the DTE is raising DTR from Off to ON to initiate a dial. If using V.25bis Async, verify that the correct character format is set to 7 data bits with even parity and 1 stop bit, and the carriage return and line feed are used as command terminators. If using V.25bis Bisync, verify that the correct character format uses two synchronous control characters and a start-of-text control character before the text block, and an end-of-text control character after the text block. If using V.25bis HDLC, verify that the character format uses flag, address, and control characters before the text block and a frame sequence check and flag after the text block. p.189
The modem dials but does not connect.If the modem is operating behind a PBX, determine if a 9 and comma are needed before the telephone number. Verify whether Tone or Pulse dialing is needed. Verify that both modems are configured the same in regard to Error Control. Try calling in Buffer mode. If both modems use V.32bis or V.32 modulation, try setting the modem’s V.32bis Train configuration option to Long. p.190
Intermittent disconnects, high error rates, or excessive retransmissions occur.Perform an End-to-End test. Refer to Pattern located in the Test Branch section of Chapter 3. p.190
The modem establishes and then disconnects the call.You may have a poor VF connection. Try dialing again. The remote modem may have encountered an error control (EC) disconnect. If the modems cannot negotiate EC, then a disconnect occurs. The remote modem may be in a forced Error Control mode (disconnect if there is no error control). Reconfigure your modem to V.42/MNP or Buffer and try again. Check the LCD to determine the reason for the disconnect. Perform a Local Analog Loopback test. p.190
High error rates occur when running a local loopback or self-test.Incoming rings can cause data errors during a loopback test. Abort the test, disconnect the modular VF cord, and restart the test. p.190
The data is scrambled.Verify that the character format (data bits, parity, and stop bits) is set to the same value in both modems. p.190
Data is missing during a transfer.Verify that you are using the same method of flow control for both the modem and the DTE. If using XON/XOFF flow control, verify that the modem’s parity matches the DTE’s parity. p.190

Ask about the Paradyne 3910

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Paradyne 3910

Be the first to ask — other owners or our team will answer.

Original document

Paradyne 3910 manual PDF

244 pages·1.5 MB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…