E1 DSU/CSU
Document No. 3170-A2-GL10-10

Copyright © 2001 Paradyne Corporation. All rights reserved. Printed in U.S.A.
Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
Internet: Visit the Paradyne World Wide Web site at www.paradyne.com. (Be sure to register your warranty at www.paradyne.com/warranty.)
Telephone: Call our automated system to receive current information by fax or to speak with a company representative.
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340
We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional information.
ACCULINK is a registered trademark of Paradyne Corporation. All other products and services mentioned herein are the trademarks, service marks, registered trademarks, or registered service marks of their respective owners.

Product Documentation Online
Complete documentation for this product is available at www.paradyne.com. Select Library → Technical Manuals → T1/E1 Digital Access Devices.
Select the following document:
3170-A2-GB20 ACCULINK 3172 and 3174 E1 DSU/CSU Operator’s Guide
To request a paper copy of a Paradyne document:
Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396)
Outside the U.S.A., call 1-727-530-8623
Before installing the DSU/CSU, read the Important Safety Instructions on page 16. Also, to ensure compliance with emissions requirements, install ferrite chokes as described in Quick Start Procedure on page 2.
Document Number 3170-A2-GL10-10 · July 2001

The following procedure is for experienced DSU/CSU users who are familiar with the 317x DSU/CSU installation process and have no special requirements for their application. See the ACCULINK 317x E1 Data Service Unit/Channel Service Unit Operator’s Guide for more information.
— Pull up on the latch to open the ferrite choke.
— Place the ferrite choke on the cable as close to the DSU/CSU as possible.
— Close the choke around the cable and press down on the latch to fasten it.
— Secure the choke with a cable tie.

The DSU/CSU is supplied with an AC power module. You must provide the DTE and network cables.
Optional cables that you can order from the company are described in Pin Assignments in the Operator’s Guide.
The 120Ω/75Ω switch selects either the 120-ohm balanced network interface or the 75-ohm unbalanced network interface. The RX SHIELD switch selects either an “open” or “earth” shield connection for the 75-ohm RX interface. (This switch must be set to “open” when using the 120-ohm interface.)


Configuration options are accessed from the Cnfig branch of the front panel menu.
ID
CID LED DL
LED
NET Prt1 Prt2 Prt3 Prt4
DCLB
UP
DN
DTE
QRSS 511
PLB
RLB
DTLB
LLB
DLB
DCLB
Load Edit Area From:
Activ Cust1 Cust2 Fact
Choose Function:
Port Select :
All Prt1 Prt2 Prt3 Prt4

Factory default configuration options are shown in boldface type in the following tables.






Sec Clk Src: NET Selects the secondary clock source for the DSU/CSU, used in the event of failure of the primary source. DTE
Clock Rate: 2048 Selects the clock rate of the source if external.
Self-Test: Enab Allows bypass of self-test on initialization.
Com Use: SNMP Controls how the COM port is used.

1.2 Selects the bit rate for the COM port.
Char Length: 7 Selects the character length for the COM port.
None Selects the parity for the COM port.
1 Selects the number of stop bits for the COM port. 1.5
Ignore DTR: Yes Specifies whether the COM port ignores DTR.
Aux Use: None Controls how the auxiliary port is used.
Aux Rate: 9.6 Configures the bit rate for the auxiliary port.

Alrm Msg: Enab Determines whether alarm messages are routed to the ASCII terminal or printer attached to the COM port. Disab
SNMP Trap: Enab Sends SNMP traps.
System Name: Edit The SNMP system name for this device.
System Location: Edit The SNMP system location for this device.
CommunityName1: Edit A community name that is allowed access to this device. Defaults to public. Clear
IP Adr: Edit The IP address needed to access the device.
NetMask: Edit The Subnet Mask needed to access the device.

Com IP Adr: Edit The IP address for the COM port when the COM port is configured for SNMP. Clear
Com NetMask: Edit The Subnet Mask needed to access the device when the COM port is configured for SNMP. Clear
Com Link: PPP The link layer protocol for the COM port when the COM port is configured for SNMP. SLIP
Aux IP Adr: Edit Specifies the IP address of the AUX port when the AUX port is configured for SNMP. Clear
Aux NetMask: Edit Specifies the Subnet Mask needed to access the device when the AUX port is configured for SNMP. Clear
Def Netwk: None Specifies the default network destination.
Com · Aux · EDLn

Num Trap Mgrs: 1 2–6 The number of trap managers supported by the device.
Trapn IP Adr: Edit Specifies the IP address for each trap manager. This configuration option is repeated for all n managers. Clear
Link Trap: Disab Specifies the link trap type to enable: Trap on Link Up, Link Down, or both. Up
Trap I/F: NET When any link trap types are enabled, specifies which links to send traps for. DTE

Important Safety Instructions
Prior to installation, use an outlet tester or a voltmeter to check the AC receptacle for the presence of earth ground. If the receptacle is not properly grounded, the installation must not continue until a qualified electrician has corrected the problem.
If a 3-wire grounding type power source is not available, consult a qualified electrician to determine another method of grounding the equipment.
Input power to the DC voltage configurations of this product must be provided by one of the following: (1) a National Electric Code (NEC)/Canadian Electric Code (CEC) Class 2 circuit for use in North America, or (2) a certified Safety Extra Low Voltage (SELV) circuit input for use in the country of installation.

— Never install telephone wiring during a lightning storm.
— Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
— Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.
— Use caution when installing or modifying telephone lines.
— Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.
— Do not use the telephone to report a gas leak in the vicinity of the leak.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation.
This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du règlement sur le matérial brouilleur du Canada.

Models 3172-A1-410 and 3174-A1-410 of this product are marked with the CE mark. This mark has been affixed to demonstrate full compliance with the following European Directives:
Directive 73/23/EEC – Council Directive of 19 February 1973 on the harmonization of the laws of the member states relating to electrical equipment designed for use within certain voltage limits, as amended by Directive 93/68/EEC.
Directive 89/336/EEC – Council Directive of 3 May 1989 on the approximation of the laws of the member states relating to Electro-Magnetic Compatibility (EMC), as amended by Directive 93/68/EEC.
Directive 91/263/EEC – Council Directive of 29 April 1991 on the approximation of the laws of the member states concerning telecommunication terminal equipment, including the mutual recognition of their conformity, as amended by Directive 93/68/EEC. The application of this directive is in relation only to network connection via the 120-ohm G.703 interface as specified in CTR12.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.