User Guide


First Edition V1 June 2008
Copyright © 2008 ASUSTeK COMPUTER INC. All Rights Reserved.
No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).
ASUS provides this manual “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose. In no event shall ASUS, its directors, officers, employees, or agents be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of use or data, interruption of business and the like), even if ASUS has been advised of the possibility of such damages arising from any defect or error in this manual or product.
Specifications and information contained in this manual ae furnished for informational use only, and are subject to change at any time without notice, and should not be construed as a commitment by ASUS. ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual, including the products and software described in it.
Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing.
Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners’ benefit, without intent to infringe.


This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with manufacturer’ s instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
This Class A digital apparatus complies with Canadian ICES-003.
This symbol of the crossed out wheeled bin indicates that the product (electrical, electronic equipment and mercury-containing button cell battery) should not be placed in municipal waste. Check local regulations for disposal of electronic products.

This product is equipped with a three-wire power cable and plug for the user’s safety. Use the power cable with a properly grounded electrical outlet to avoid electrical shock.
Lithium-Ion Battery Warning CAUTION! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
CLASS 1 LASER PRODUCT
Heavy System CAUTION! This server system is heavy. Ask for assistance when moving or carrying the system.

This user guide is intended for system integrators, and experienced users with at least basic knowledge of configuring a server.
This guide contains the following parts:
This chapter describes the general features of the server, including sections on front panel and rear panel specifications.
This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.
This chapter describes how to install optional components into the barebone server.
This chapter gives information about the motherboard that comes with the server. This chapter includes the motherboard layout, jumper settings, and connector locations.
This chapter tells how to change system settings through the BIOS Setup menus and describes the BIOS parameters.
This chapter tells how to change system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.
This chapter provides instructions for installing the necessary drivers for different system components.

To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual.
Bold text Indicates a menu or an item to select.
Italics Used to emphasize a word or a phrase.
Keys enclosed in the less-than and greater- than sign means that you must press the enclosed key.
Example: means that you must press the Enter or Return key.
If you must press two or more keys simultaneously, the key names are linked with a plus sign (+).
Command Means that you must type the command exactly as shown, then supply the required item or value enclosed in brackets.
Refer to the following sources for additional information, and for product and software updates.
This manual tells how to set up and use the proprietary ASUS server management utility.
The ASUS websites worldwide provide updated information for all ASUS hardware and software products. Refer to the ASUS contact information.

Product introduction
This chapter describes the general features of the chassis kit. It includes sections on front panel and rear panel specifications.


Check your system package for the following items.
Model Name TS500-E5/PA4 TS500-E5/RX8
Chassis ASUS T55 Pedestal 5U Rackmount Chassis
ASUS T55 Pedestal 5U Rackmount Chassis
Motherboard ASUS DSAN-DX/TS500-E5 Server Board
ASUS DSAN-DX/TS500-E5 Server Board
Component 1 x 670W Single Power Supply 1 x SATA/SAS Backplane (BP4LX-T55) with 4 x SATA Cables 4 x Hot-swap HDD trays 1 x Floppy Disk Drive 1 x Front I/O Board 1 x System RearFan (120mm x 38mm)
1 x 650W Redundant Power Supply 1 x SATA/SAS Backplane (BP4LX-T55) with 4 x SATA Cables 4 x Hot-swap HDD trays 1 x Floppy Disk Drive 1 x Front I/O Board 1 x System RearFan (120mm x 38mm)
Accessories 2 x CPU Coolers 1 x ASUS TS500-E5 User’s Guide 1 x ASUS ASWM 2.0 User’s Guide 1 x TS500-E5 Support CD (including ASWM*) 1 x Bag of Screws 1 x AC Power Cable
2 x CPU Coolers 1 x ASUS TS500-E5 User’s Guide 1 x ASUS ASWM 2.0 User’s Guide 1 x TS500-E5 Support CD (including ASWM*) 1 x Bag of Screws 1 x AC Power Cable
Optional Items CA eTrust Anti-virus Software CD ASUS TS500-E5 Rackmount Rail Kit 4-bay HDD Cage ASUS PIKE RAID Card
CA eTrust Anti-virus Software CD ASUS TS500-E5 Rackmount Rail Kit 650W Redundant Power Supply Module 4-bay HDD Cage ASUS PIKE RAID Card
*ASUS System Web-based Management
If any of the above items is damaged or missing, contact your retailer.
Before requesting support from the ASUS Technical Support team, you must take note of the product’s serial number containing 12 characters such as xxxxxxxxxxxx. See the figure below.
With the correct serial number of the product, ASUS Technical Support team members can then offer a quicker and satisfying solution to your problems.


The ASUS TS500-E5 is a 5U barebone server system featuring the ASUS DSAN-DX/TS500-E5 server board. The server supports Intel
® 5100 / 5200 / 5300 / 5400 series processors with EM64T technology, plus other latest technologies through the chipsets onboard.
Model Name TS500-E5/PA4 TS500-E5/RX8 Processor / System Bus 2 x Socket LGA771 Quad-Core Intel
® 5400 series Dual-Core Intel
® 5200 series Quad-Core Intel
® 5300 series Dual-Core Intel
® 5100 series FSB 1066/1333 MHz EM64T Core Logic Intel
® 5100 Memory Controller Hub (MCH) Intel
® ICH9R ASUS Features Smart Fan √ ASWM2.0 √ Memory Total Slots 6 (Dual-Channel) Capacity Maximum up to 24GB Memory Type DDR2 667 Registered ECC Memory Size 512 MB, 1 GB, 2GB and 4GB Expansion Slots Total PCI/PCI-X/
Slot Type Workstation Mode: 1 x PCI-E x16 slot (x16 link) 1 x PCI-E x8 slot (x8 link) 1 x PCI-E x8 slot (x4 link) or PIKE 1 x PCI 32-bit/33MHz slot
Server Mode: 1 x PCI-E x16 slot (x8 link) 2 x PCI-E x8 slot (x8 link) 1 x PCI-E x8 slot (x4 link) or PIKE 1 x PCI 32-bit/33MHz slot Additional Slot 1 1 x SO-DIMM socket Additional Slot 2 1 x Proprietary slot for optional ASUS PIKE Storage SATA Controller Intel
® ICH9R: 6 x SATA2 300MB/s ports Intel Matrix Storage (for Windows only) (Support software RAID 0, 1, 5 & 10)
LSI MegaRAID (for Linux/Windows) (Support software RAID 0, 1 & 10) SAS Controller Optional: ASUS PIKE 1064E 4 port SAS card - Supports RAID 0, 1 and 1E ASUS PIKE 1078 8 port SAS card - Supports RAID 0, 1, 5, 10, 50, 6 and 60
(continued on the next page)

Model Name TS500-E5/PA4 TS500-E5/RX8 HDD Bays I = internal A or S will be hot-swappable
Configuration Option: 4-bay HDD Cage + 4 x Hot-swap HDD Trays Networking LAN 2 x Broadcom ® BCM5721 PCI-E GbE LAN Graphic VGA XGI Z9S VGA Controller / 32MB DDRII SDRAM Auxiliary Storage FDD / CD / DVD 1 x FDD 2 x 5.25" media bays (Options: No ODD/DVD-ROM/DVD-RW) Onboard I/O 1 x External Serial Port 2 x RJ-45 ports 4 x USB 2.0 ports (Front x 2, Rear x 2) 1 x VGA port 1 x PS/2 keyboard port 1 x PS/2 mouse port
® Server 2003 R2 Enterprise 32/64-bit RedHat
® Enterprise Linux AS5 UP1 32/64-bit SuSE
® Linux Enterprise Server 10 SP1 32/64-bit (Subject to change without any notice) Anti-virus Software CA
® eTrust™ 7.1 anti-virus software (Optional) Management Solution ASUS ASWM 2.0 and SNMP Dimension (HH x WW x DD) 450mm x 212mm x 550mm Net Weight Kg (CPU, DRAM & HDD not included)
Power Supply 670W Single Power Supply
650W 1+1 Redundant Power Supply Environment Operation temperature: 10°C ~ 35°C Non operation temperature: -40°C ~ 70°C Non operation humidity: 20% ~ 90% ( Non condensing)
*Specifications are subject to change without notice.
Windows · OS Support · 20Kg

The barebone server displays a simple yet stylish front panel with easily accessible features. The power and reset buttons, LED indicators, optical drive, and two USB ports are located on the front panel.
The drive bays, power and reset buttons, LED indicators, CD/DVD-ROM drive, floppy drive, and USB 2.0 ports are located on the front panel. For future installation of 5.25-inch devices, two drive bays are available.

Empty 5.25-inch
USB 2.0 ports
Refer to section 1.7.1 Front panel LEDs for the LED descriptions.


This server system provides 4-bay HDD Cage + 4 x Hot-swap HDD Trays as optional items.
4-bay HDD cage · 4-bay HDD cage

The rear panel includes a slot for the motherboard rear I/O ports, expansion slots, a chassis lock and intrusion switch, a vent for the system fan, and power supply module.

670W Single power supply
USB 2.0 ports
120mm x 38mm system fan
Gigabit LAN port 1
Gigabit LAN port 2

650W Redundant power supply
The second redundant power supply is an optional item.

The barebone server includes the basic components as shown.


LAN1 LED LAN2 LED HDD Access LED
LED Icon Display status Description Power LED ON System power ON
HDD Access LED OFF Blinking
No activity Read/write data into the HDD
Message LED OFF Blinking
System is normal; no incoming event ASWM indicates a HW monitor event
Bridge board connected to backplane Installed HDD is in good condition
HDD rebuilding using the RAID card
Read/write data into the HDD
The Power, HDD Access, LAN and Message LEDs are visible even if the system front bezel is closed.


SPEED LED
ACT/LINK LED
SPEED LED
ACT/LINK LED SPEED LED Status Description Status Description OFF No link OFF 10 Mbps connection GREEN Linked ORANGE 100 Mbps connection BLINKING Data activity GREEN 1 Gbps connection

Hardware setup
This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.


To reinstall the side cover:



To reinstall the side cover:


The motherboard comes with a surface mount LGA771 socket designed for the Intel® Xeon® Dual/Quad Core processor.
To install a CPU:


Before installing the CPU, make sure that the socket box is facing towards you and the load lever is on your left.


B
This side of the socket box should face you.
To prevent damage to the socket pins, do not remove the PnP cap unless you are installing a CPU.


A


The CPU fits in only one correct orientation. DO NOT force the CPU into the socket to prevent bending the connectors on the socket and damaging the CPU!


To install the CPU heatsink and fan:



Do not forget to connect the CPU heatsink and fan connector! Hardware monitoring errors can occur if you fail to plug this connector.


The motherboard comes with six (6) Double Data Rate 2 (DDR2) Dual Inline Memory Modules (DIMM) sockets.
A DDR2 module has the same physical dimensions as a DDR DIMM but has a 240-pin footprint compared to the 184-pin DDR DIMM.
The figure illustrates the location of the DDR2 DIMM sockets:`

You may install 512 MB, 1 GB, 2 GB, and 4 GB registered ECC DIMMs into the DIMM sockets.

DIMM_A3
DIMM_B3
DIMM_A2
DIMM_B2
DIMM_A1
DIMM_B1
MCH
DIMM installation reference table
No. of DIMMs
1 DIMM_B1 or DIMM_A1
4 DIMM_B1, DIMM_A1, DIMM_B2, DIMM_A2
6 DIMM_B1, DIMM_A1, DIMM_B2, DIMM_A2 DIMM_B3, DIMM_A3
Slot/s to use

The Intel® 5100MCH chipset supports the memory sparing technology. Refer to the below section:
At configuration time, a DIMM rank is set aside to replace a defective DIMM rank. When the error rate for a failing DIMM rank reaches a pre-determined threshold, the memory sparing function will issue an interrupt and initiate a spare copy. At the completion of the copy, the failing DIMM rank is disabled and the “spared” DIMM rank will be used in its place. Refer to section 5.4.3 Chipset and configure the options of Channel Rank Sparing or Channel 1 Rank Sparing to enable the memory sparing functions. The default BIOS setting is disabled.
The following tables show memory configurations with Memory Sparing function in Channel A/B.
One DIMM per channel (two ranks)
Channel B Channel A
Rank 0 (1024 MB)
Rank 1 (1024 MB)
Rank 0 (1024 MB)
Rank 1 (1024 MB)
Memory space 1024 MB 1024 MB
Total Memory 2048 MB
DIMM_B1 (1024MB*2 Ranks) · DIMM_A1 (1024MB*2 Ranks) · Sparing

Two DIMMs per channel

Three DIMMs per channel


Make sure to unplug the power supply before adding or removing DIMMs or other system components. Failure to do so may cause severe damage to both the motherboard and the components.
To install a DIMM:

To remove a DIMM:
Support the DIMM lightly with your fingers when pressing the retaining clips. The DIMM might get damaged when it flips out with extra force.
DDR2 DIMM notch 1
DDR2 DIMM notch · Unlocked retaining clip

Before you can install a 5.25-inch drive, you should first remove the front panel assembly (front bezel and front panel cover).
To remove the front panel assembly:

To reinstall the front panel assembly:


Ensure to unplug the power cable before installing or removing any system components. Failure to do so may cause damage to the motherboard and other system components!
The system comes with three 5.25-inch drive bays located on the upper front part of the chassis. You can use the bay converter that comes with the package to convert the 5.25-inch bay to 3.5-inch bay for 3.5-inch device such as floppy disk drives.

You must remove the front panel assembly before installing a 5.25-inch drive.


screw hole · IDE cable · Power plug



3.5" Floppy disk drive 3.5" Hard disk drive

The optional two hard disk drive modules on the front panel, including externally removable trays for mounting either SATA or SAS hard disk drives, allow you to access the drive trays by simply opening the the front bezel.
A hot-swap HDD module cage comes with a SATA or SATS backplane. Make sure of the type of HDD module cage you purchase before buying hard disks.









DO NOT remove the backplane unless necessary!



The system is designed with an expansion card lock on the rear panel for you to install or remove an expansion card in less steps.
Ensure to unplug the power cord before installing or removing expansion cards. Failure to do so may cause severe damage to the motheboard and other system components!





When installing a graphics card on PCI-E x16 slot, the PCI-E slot right beside it does not function.
Follow the steps below to install an optional ASUS RAID card on your motherboard.



When installing a PIKE RAID card on the PIKE RAID card slot, the PCI-E slot right beside it does not function.

After installing the expansion card, configure the it by adjusting the software settings.

* These IRQs are usually available for ISA or PCI devices.

24.5cm (9.6in)


A SATA/SAS backplane comes pre-installed in the TS500-E5. The SATA/SAS backplane has four 22-pin SATA/SAS connectors to support Serial ATA hard disk drives and SAS hard disk drives. The backplane design incorporates a hot swap feature to allow easy connection or removal of SATA/SAS hard disks. The LEDs on the backplane connect to the front panel LEDs to indicate HDD status. See section “1.6 LED information” for details.
The front side of the SATA/SAS backplane faces the front panel when installed. This side includes four SATA/SAS connectors for the hot swap drive trays.

Each SATA/SAS connector is labeled (CON0, CON1, CON2, CON3) so you can easily determine their counterpart connectors at the back side of the backplane. Refer to the table for reference.

HDD Device Front side connector Back side connector
HDD 2 CON1 CON5
HDD 3 CON2 CON6
HDD 4 CON3 CON7
Drive status LEDs

The back side of the SATA/SAS backplane faces the rear panel when installed. This side includes the power connectors and SATA/SAS interfaces for the motherboard Serial ATA connectors or the SAS card.

J2 Connects to SATA SGPIO1 connector on the motherboard
J6 Connects to SAS SGPIO2 connector on the motherboard
J7 Connects to SAS SGPIO3 connector on the motherboard
J8 Links backplane1 and backplane2 signals
J10 Links to add-on card failed LED signal
U1 Connects to 4-pin plug of the power supply
CON6/CON7 Connects to SATA/SAS connectors on the motherboard
Connectors Description

You may need to remove previously installed system components when installing or removing system devices, or when you need to replace defective components. This section tells how to remove the following components:
To remove the system fan:




To reinstall the system fan:

The barebone server system is shipped with four footpads attached to the bottom of the chassis for stability. You need to remove these footpads if you wish to install the system to a rack (Refer to Chapter 3: Installation options of this user guide, and to the “Rackmount Kit” user guide for instructions)
To remove the footpads:



The system is compatible with both EPS 12 V 670 W single power supply and 650 W redundant power supply. Purchase based on your needs.
You MUST disconnect all power cable plugs from the motherboard and other installed devices before removing the power supply unit.










Installation options
This chapter describes how to install the optional components and devices into the barebone server.

Refer to section 2.9.2 Chassis footpads for instructions on removing the footpads.

Unscrew and slide the top cover toward the rear panel, and then lift it up from the chassis.



To attach the rails to the rack:



1U space

To mount the server to the rack:



Motherboard info
This chapter includes the motherboard layout, and brief descriptions of the jumpers and internal connectors.

24.5cm (9.6in)

24.5cm (9.6in)

® ICH9R SATA port S/W RAID setting (3-pin RAID_SEL1) 4-8
Jumpers Page · Internal connectors Page

This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords.
To erase the RTC RAM:

Except when clearing the RTC RAM, never remove the cap on CLRTC jumper default position. Removing the cap will cause system boot failure!
If the steps above do not help, remove the onboard battery and move the jumper again to clear the CMOS RTC RAM data. After the CMOS clearance, reinstall the battery.

This jumper allows you to enable or disable the onboard VGA controller. Set to pins 1–2 to activate the VGA feature.

3. LAN controller setting (3-pin LAN_SW1, LAN_SW2)
These jumpers allow you to enable or disable the onboard Broadcom® BCM5721 Gigabit LAN1/2 controller. Set to pins 1–2 to activate the Gigabit LAN feature.


This jumper allows you to switch for fan pin selection. The CPUFAN_SEL1 jumper is for the CPU fans control. Set to pins 1–2 when using 4-pin fans or pins 2–3 when using 3-pin fans.

This jumper allows you to switch for fan pin selection. The CHAFAN_SEL1 jumper is for the system fans control. Set to pins 1–2 when using 4-pin fans or pins 2–3 when using 3-pin fans.


This jumper allows you to enable or disable the onboard IDE connector. Set to pins 1–2 to activate the IDE connector.

This jumper allows you to quickly update or recover the BIOS settings when it becomes corrupted.
To update the BIOS:

Use the AFUDOS uitility version 3.12 to flash the BIOS.

® ICH9R SATA port S/W RAID setting (3-pin RAID_SEL1)
This jumper allows you to select the Serial ATA RAID configuration utility to use when you create disk arrays. Both utilities are supported by the Intel
® ICH9R. Place the jumper caps on pins 1–2 if you want to use the LSI Software RAID Configuration Utility (default); otherwise, place the jumper caps on pins 2–3 to use the Intel
® Matrix Storage Manager (IMSM).

This jumper allows you to select the RAID configuration utility to use when you create disk arrays. Place the jumper caps on pins 1–2 if you install a PIKE RAID card to the motherboard and want to use the LSI Logic MPT Setup Utility (default). Or you can place the jumper caps on pins 2–3 to create the LSI Mega RAID 5 by supported Intel
® ICH9R SATA controller.


This connector is for the provided floppy disk drive (FDD) signal cable. Insert one end of the cable to this connector, then connect the other end to the signal connector at the back of the floppy disk drive.
Pin 5 on the connector is removed to prevent incorrect cable connection when using a FDD cable with a covered Pin 5.

FLOPPY NOTE:Orient the red markings on the floppy ribbon cable to PIN 1.
DSAN-DX/TS500-E5 Floppy disk drive connector
2. Serial ATA connectors [black] (7-pin SATA1-6)
These connectors, controlled by southbridge ICH9R, are for the Serial ATA signal cables for Serial ATA hard disk drives.

GND RSATA_TXP1 RSATA_TXN1
SATA2 GND RSATA_1TXP2
RSATA_TXN2
GND RSATA_RXN1 RSATA_RXP1
GND RSATA_RXN2 RSATA_RXP2
GND
GND
SATA3
GND RSATA_TXP3 RSATA_TXN3
SATA4 GND RSATA_TXP4 RSATA_TXN4
GND RSATA_RXN3 RSATA_RXP3
GND RSATA_RXN4 RSATA_RXP4
GND
GND
SATA5
GND RSATA_TXP5 RSATA_TXN5
SATA6 GND RSATA_TXP6 RSATA_TXN6
GND RSATA_RXN5 RSATA_RXP5
GND RSATA_RXN6 RSATA_RXP6
GND
GND
DSAN-DX/TS500-E5 SATA connectors

This connector is for an Ultra DMA 100/66 signal cable. The Ultra DMA 100/66 signal cable has three connectors: a blue connector for the primary IDE connector on the motherboard, a black connector for an Ultra DMA 100/66 IDE slave device (optical drive/hard disk drive), and a gray connector for an Ultra DMA 100/66 IDE master device (hard disk drive). If you install two hard disk drives, you must configure the second drive as a slave device by setting its jumper accordingly. Refer to the hard disk documentation for the jumper settings.


This motherboard comes with eight (8) Serial Attached SCSI (SAS) connectors, the next-generation storage technology that supports both Series SCSI and Serial ATA (SATA). Each connector supports one device.
![Asus TS500-E5 — 4. SAS connectors [red] (7-pin SAS1-4), [blue] (7-pin SAS5-8) diagram (page 65)](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/fig-65-1.webp)
SAS3
SAS2
SAS1
GND RSATA_TXP4 RSATA_TXN4
GND RSATA_TXP3 RSATA_TXN3
GND RSATA_TXP2 RSATA_TXN2
GND RSATA_TXP1 RSATA_TXN1
GND RSATA_RXN4 RSATA_RXP 4
GND RSATA_RXN3 RSATA_RXP3
GND RSATA_RXN2 RSATA_RXP2
GND RSATA_RXN1 RSATA_RXP1
GND
GND
GND
GND
SAS8
SAS7
SAS6
SAS5
GND RSATA_TXP8 RSATA_TXN8
GND RSATA_TXP7 RSATA_TXN7
GND RSATA_TXP6 RSATA_TXN6
GND RSATA_TXP5 RSATA_TXN5
GND RSATA_RXN8 RSATA_RXP8
GND RSATA_RXN7 RSATA_RXP7
GND RSATA_RXN6 RSATA_RXP6
GND RSATA_RXN5 RSATA_RXP5
GND
GND
GND
GND
5. Hard disk activity LED connector (4-pin HDLED1)
This connector is used to connect to a hard disk drive active LED connector on the SCSI or RAID card.

DSAN-DX/TS500-E5 SAS connectors

This connector is used for the SGPIO peripherals for the LSI MegaRAID SATA LED.

7. Serial General Purpose Input/Output connectors (6-1 pin SGPIO2/3)
These connector is used for the SAS chip SIO interface that controls the LED pattern generation, device information and general purpose data.

SIO_DOUT
SIO_DIN
SIO_DIN
GND
GND
SGPIO3
SGPIO2
PIN 1
PIN 1
GND
GND
SIO_END
SIO_CLK
GND
GND
SIO_END
SIO_CLK
DSAN-DX/TS500-E5 SGPIO2/3 connectors
These connectors functions only when you install a PIKE SAS RAID card.

These connectors is for USB 2.0 ports. Connect the USB module cable to the connectors, then install the module to a slot opening at the back of the system chassis. The USB connectors comply with USB 2.0 specification that supports up to 480 Mbps connection speed.

USB34
NC GND USB_P6+
NC GND USB_P4+
GND USB_P5+ USB_P5USB+5V
GND USB_P3+ USB_P3USB+5V
USB_P6-
USB+5V
USB_P4-
USB+5V
PIN 1
PIN 1
DSAN-DX/TS500-E5 USB 2.0 connectors
The USB port module is purchased separately.
The fan connectors support cooling fans of 350 mA–740 mA (8.88 W max.) or a total of 3.15 A–6.66 A (53.28 W max.) at +12V. Connect the fan cables to the fan connectors on the motherboard, making sure that the black wire of each cable matches the ground pin of the connector.

DO NOT forget to connect the fan cables to the fan connectors. Insufficient air flow inside the system may damage the motherboard components. These are not jumpers! DO NOT place jumper caps on the fan connectors!

This connector is for a serial (COM) port. Connect the serial port module cable to this connector, then install the module to a slot opening at the back of the system chassis.

This connector is for the power supply SMB cable, if your power supply supports the SMBus function.


These connectors are for SSI power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit.


This connector supports several chassis-mounted functions.
![Asus TS500-E5 — 13. System panel connector [white] (20-pin PANEL1) diagram (page 70)](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/fig-70-1.webp)

This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs.
![Asus TS500-E5 — 14. Auxiliary panel connector [black] (20-pin AUX_PANEL1) diagram (page 71)](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/fig-71-1.webp)
I2C_4_DATA#
LAN1_LINK
LAN1_ACT
LAN2_ACT
LAN2_LINK
+5VSB
GND
NC
AUX_PANEL1
PIN 1
+5VSB
CASEOPEN
GND
LOCATORLED1+
LOCATORLED1-
LOCATORBTN#
GND
LOCATORLED2-
LOCATORLED2+
DSAN-DX/TS500-E5 Auxiliary panel connector


This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.

The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup:
Refer to the corresponding sections for details on these utilities.
Save a copy of the original motherboard BIOS file to a bootable floppy disk in case you need to restore the BIOS in the future. Copy the original motherboard BIOS using the ASUS Update or AFUDOS utilities.
a. Insert a 1.44MB floppy disk into the drive.
b. At the DOS prompt, type format A:/S then press .
a. Insert a 1.44 MB floppy disk to the floppy disk drive.
b. Click Start from the Windows
® desktop, then select My Computer.
c. Select the 3 ½ Floppy Drive icon.
d. Right click File from the menu, then select Format. A Format 3½ Floppy Disk window appears.
e. Select Create an MS-DOS startup disk from the format options field, then click Start.
DOS environment · Windows · ® environment
![Page 75 of the Asus TS500-E5 user manual — afudos /o[filename]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-75.webp?w=400)
The AFUDOS utility allows you to update the BIOS file in DOS environment using a bootable floppy disk with the updated BIOS file. This utility also allows you to copy the current BIOS file that you can use as backup when the BIOS fails or gets corrupted during the updating process.
To copy the current BIOS file using the AFUDOS utility:
where the [filename] is any user-assigned filename not more than eight alphanumeric characters for the main filename and three alphanumeric characters for the extension name.
A:\>afudos /oOLDBIOS1.rom
Main filename Extension name
A:\>afudos /oOLDBIOS1.rom AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB)) Copyright (C) 2002 American Megatrends, Inc. All rights reserved. Reading flash done Write to file ok A:\>
The utility returns to the DOS prompt after copying the current BIOS file.
![Page 76 of the Asus TS500-E5 user manual — afudos /i[filename]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-76.webp?w=400)
To update the BIOS file using the AFUDOS utility:
Write the BIOS filename on a piece of paper. You need to type the exact BIOS filename at the DOS prompt.
where [filename] is the latest or the original BIOS file on the bootable floppy disk, then press .
A:\>afudos /iTS500-E5.ROM
The utility verifies the file, then starts updating the BIOS file.
A:\>afudos /iTS500-E5.ROM AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB)) Copyright (C) 2002 American Megatrends, Inc. All rights reserved. WARNING!! Do not turn off power during flash BIOS Reading file done Reading flash done
Advance Check Erasing flash done Writing flash 0x0008CC00 (9%)
DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure!

A:\>afudos /iTS500-E5.ROM AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB)) Copyright (C) 2002 American Megatrends, Inc. All rights reserved. WARNING!! Do not turn off power during flash BIOS Reading file done Reading flash done Advance Check Erasing flash done Writing flash done Verifying flash done
Please restart your computer
Updating the BIOS file using a USB flash drive
If you have not purchased a USB floppy disk drive, you may update the BIOS file using a USB flash drive. Format the USB flash drive to FAT16 or 32 system file before updating the BIOS.
To format the USB flash drive to a FAT32/16 system file:
To update the BIOS file:

The ASUS CrashFree BIOS 3 is an auto recovery tool that allows you to restore the BIOS file when it fails or gets corrupted during the updating process. You can update a corrupted BIOS file using a floppy disk or a USB flash drive that contains the updated BIOS file.
Prepare a floppy disk or a USB flash drive containing the updated motherboard BIOS before using this utility.
To recover the BIOS from a floppy disk:
To recover the BIOS from a USB flash drive:
DO NOT shut down or reset the system while recovering the BIOS! Doing so would cause system boot failure!
The recovered BIOS may not be the latest BIOS version for this motherboard. Visit the ASUS website (www.asus.com) to download the latest BIOS file.

This motherboard supports a programmable Low-Pin Count (LPC) chip that you can update using the provided utility described in section 5.1 Managing and updating your BIOS.
Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to “Run Setup.” This section explains how to configure your system using this utility.
Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future. For example, you can enable the security password feature or change the power management settings. This requires you to reconfigure your system using the BIOS Setup program so that the computer can recognize these changes and record them in the CMOS RAM of the LPC chip.
The LPC chip on the motherboard stores the Setup utility. When you start up the computer, the system provides you with the opportunity to run this program. Press during the Power-On Self-Test (POST) to enter the Setup utility; otherwise, POST continues with its test routines.
If you wish to enter Setup after POST, restart the system by pressing , or by pressing the reset button on the system chassis. You can also restart by turning the system off and then back on. Do this last option only if the first two failed.
The Setup program is designed to make it as easy to use as possible. Being a menu-driven program, it lets you scroll through the various sub-menus and make your selections from the available options using the navigation keys.

Configuration fields Menu items
General help Menu bar
BIOS SETUP UTILITY Main Advanced Server Power Boot Exit
System Time [13:44:30] System Date [Tue, 10/11/2007] Legacy Diskette [1.44 MB, 3.5 in.]
Use [ENTER], [TAB] or [SHIFT-TAB] to select a field.
Use [+] or [-] to configure system Date.
SATA1 : [Not Detected] SATA2 : [Not Detected] SATA3 : [Not Detected] SATA4 : [Not Detected] SATA5 : [Not Detected] SATA6 : [Not Detected] PATA Master : [Not Detected] PATA Slvae : [Not Detected] IDE Configuration
←→ Select Screen ↑↓ Select Item +- Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
The menu bar on top of the screen has the following main items:
Main For changing the basic system configuration
Advanced For changing the advanced system settings
Server For changing the advanced server settings
Power For changing the advanced power management (APM) configuration
Boot For changing the system boot configuration
Exit For selecting the exit options and loading default settings
To select an item on the menu bar, press the right or left arrow key on the keyboard until the desired item is highlighted.
At the bottom right corner of a menu screen are the navigation keys for that particular menu. Use the navigation keys to select items in the menu and change the settings.
Some of the navigation keys differ from one screen to another.
System Information · Sub-menu items · Navigation keys

The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main shows the Main menu items.

System Time [11:17:09] System Date [Tue 01/22/2008] Legacy Diskette A [1.44 MB 3.5 in.]
select a field.
Use [+] or [-] to
Date.
PATA Master [Not Detected]
PATA Slave [Not Detected]
The other items (Advanced, Power, Boot, and Exit) on the menu bar have their respective menu items.
A solid triangle before each item on any menu screen means that the item has a sub-menu. To display the sub-menu, select the item and press .
These fields show the values for the menu items. If an item is user-configurable, you can change the value of the field opposite the item. You cannot select an item that is not user-configurable.
A configurable field is enclosed in brackets, and is highlighted when selected. To change the value of a field, select it then press to display a list of options. Refer to 5.2.7 Pop-up window.
Select a menu item then press to display a pop-up window with the configuration options for that item.

A scroll bar appears on the right side of a menu screen when there are items that do not fit on the screen. Press the Up/Down arrow keys or / keys to display the other items on the screen.
At the top right corner of the menu screen is a brief description of the selected item.
![Page 82 of the Asus TS500-E5 user manual — 5.3.3 Legacy Diskette A [Disabled]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-82.webp?w=400)
When you enter the BIOS Setup program, the Main menu screen appears, giving you an overview of the basic system information.
Refer to section 5.2.1 BIOS menu screen for information on the menu screen items and how to navigate through them.
BIOS SETUP UTILITY Main Advanced Server Power Boot Exit
System Time [13:44:30] System Date [Tue, 10/11/2007] Legacy Diskette A [Disabled]
Use [ENTER], [TAB] or [SHIFT-TAB] to select a field.
Use [+] or [-] to configure system Date.
SATA1 : [Not Detected] SATA2 : [Not Detected] SATA3 : [Not Detected] SATA4 : [Not Detected] SATA5 : [Not Detected] SATA6 : [Not Detected] PATA Master : [Not Detected] PATA Slvae : [Not Detected] IDE Configuration
←→ Select Screen ↑↓ Select Item +- Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Allows you to set the system time.
Allows you to set the system date.
Sets the type of floppy drive installed. Configuration options: [Disabled] [360 KB, 5.25 in.] [1.2 MB, 5.25 in.] [720 KB, 3.5 in.] [1.44 MB, 3.5 in] [2.88 MB, 3.5 in]
System Information
![Page 83 of the Asus TS500-E5 user manual — Block (Multi-Sector Transfer) M [Auto]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-83.webp?w=400)
The BIOS automatically detects the connected IDE devices. There is a separate sub-menu for each IDE device. Select a device item, then press to display the IDE device information.
The PATA device is for ODD (optical disk drive) only.
BIOS SETUP UTILITY Main
Primary IDE Master Device :Hard Disk Vendor :xxxxxxxxx Size :xx.xGB LBA Mode :Supported Block Mode:16Sectors PIO Mode :4 Async DMA :MultiWord DMA-2 Ultra DMA :Ultra DMA-6 S.M.A.R.T.:Supported
Select the type of device connected to the system.
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
Type [Auto] LBA/Large Mode [Auto] Block(Multi-Sector Transfer)M [Auto] PIO Mode [Auto] DMA Mode [Auto] SMART Monitoring [Auto] 32Bit Data Transfer [Enabled]
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
The BIOS automatically detects the values opposite the dimmed items (Device, Vendor, Size, LBA Mode, Block Mode, PIO Mode, Async DMA, Ultra DMA, and S.M.A.R.T. monitoring). These values are not user-configurable. These items show N/A if no IDE device is installed in the system.
Selects the type of IDE drive. Setting to [Auto] allows automatic selection of the appropriate IDE device type. Select [CDROM] if you are specifically configuring a CD-ROM drive. Select [ARMD] (ATAPI Removable Media Device) if your device is either a ZIP, LS-120, or MO drive. Configuration options: [Not Installed] [Auto] [CD/DVD] [ARMD]
Enables or disables the LBA mode. Setting to [Auto] enables the LBA mode if the device supports this mode, and if the device was not previously formatted with LBA mode disabled. Configuration options: [Disabled] [Auto]
Enables or disables data multi-sectors transfers. When set to [Auto], the data transfer from and to the device occurs multiple sectors at a time if the device supports multi-sector transfer feature. When set to [Disabled], the data transfer from and to the device occurs one sector at a time. Configuration options: [Disabled] [Auto]
![Page 84 of the Asus TS500-E5 user manual — 32Bit Data Transfer [Enabled]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-84.webp?w=400)
Allows you to select the data transfer mode. Configuration options: [Auto] [0] [1] [2] [3] [4]
Sets the DMA mode. Configuration options: [Auto] [SWDMA0] [SWDMA1] [SWDMA2] [MWDMA0] [MWDMA1] [MWDMA2] [UDMA0] [UDMA1] [UDMA2] [UDMA3] [UDMA4] [UDMA5] [UDMA6]
Sets the Smart Monitoring, Analysis, and Reporting Technology. Configuration options: [Auto] [Disabled] [Enabled]
Enables or disables 32-bit data transfer. Configuration options: [Disabled] [Enabled]
![Page 85 of the Asus TS500-E5 user manual — Hard Disk Write Protect [Disabled]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-85.webp?w=400)
The items in this menu allow you to set or change the configurations for the IDE devices installed in the system. Select an item then press if you wish to configure the item.
BIOS SETUP UTILITY Main
SATA#1 Configuration [Enhanced] Configure SATA#1 as [IDE] SATA#2 Configuration [Enhanced]
Hard Disk Write Protect [Disabled]
←→ Select Screen ↑↓ Select Item +- Change Field F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Configure SATA#1 as [IDE] Sets the configuration for the Serial ATA connectors supported by the Southbridge chip. Configuration options: [IDE] [RAID] [AHCI]
If you want to create a RAID 0, RAID 1, RAID 5, RAID 10, or the Intel® Matrix Storage Technology configuration from the Serial ATA hard disk drives, set this item to [RAID].
If you want to use the Serial ATA hard disk drives as Parallel ATA physical storage devices, keep the default setting [IDE].
If you want the Serial ATA hard disk drives to use the Advanced Host Controller Interface (AHCI), set this item to [AHCI]. The [AHCI] option allows the onboard storage driver to enable advanced Serial ATA features that increases storage performance on random workloads by allowing the drive to internally optimize the order of commands.
Disables or enables device write protection. This will be effective only if device is accessed through BIOS. Configuration option: [Disabled] [Enabled]
IDE Configuration · Options · Disabled Compatible Enhanced

This menu gives you an overview of the general system specifications. The BIOS automatically detects the items in this menu.
BIOS SETUP UTILITY Main
←→ Select Screen ↑↓ Select Item F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Displays the auto-detected BIOS information.
Displays the auto-detected CPU specification.
Displays the auto-detected system memory.
System Information · Processor · System Memory

The Advanced menu items allow you to change the settings for the CPU and other system devices.
Take caution when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction.
BIOS SETUP UTILITY Main Advanced Server Power Boot Exit
Configure the USB support. USB Configuration
CPU Configuration Chipset Onboard Devices Configuration PCIPnP
←→ Select Screen ↑↓ Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
The items in this menu allows you to change the USB-related features. Select an item then press to display the configuration options.
BIOS SETUP UTILITY Advanced
Module Version - 2.24.3-13.4
USB Devices Enabled:
USB Functions [Enabled] Legacy USB Support [Enabled] USB 2.0 Controller Mode [HiSpeed] BIOS EHCI Hand-Off [Enabled] ←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
The USB Devices Enabled item shows the auto-detected values. If no USB device is detected, the item shows None.
![Page 88 of the Asus TS500-E5 user manual — BIOS EHCI Hand-Off [Enabled]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-88.webp?w=400)
Allows you to enable the USB host controller. Configuration options: [Disabled] [Enabled]
The following item appears only when you set USB Function to [Enabled].
Allows you to enable or disable support for legacy USB devices. Setting to [Auto] allows the system to detect the presence of USB devices at startup. If detected, the USB controller legacy mode is enabled. If no USB device is detected, the legacy USB support is disabled. Configuration options: [Disabled] [Enabled] [Auto]
The following item appears only when you set USB Function to [Enabled].
Allows you to set the USB 2.0 controller to HiSpeed (480Mbps) or FullSpeed (12Mbps). Configuration options: [FullSpeed] [HiSpeed]
Enables or disables the BIOS EHCI hand-off support. Configuration options: [Disabled] [Enabled]
![Page 89 of the Asus TS500-E5 user manual — *Adjacent Cache Line Prefetch [Enabled]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-89.webp?w=400)
The items in this menu show the CPU-related information that the BIOS automatically detects. Some items may not appear if you CPU does not support the related functions.
BIOS SETUP UTILITY Advanced
Configure advanced CPU settings Module Version:3F.06 Manufacturer:Intel Brand String:Intel(R) Xeon(R) CPU 5150 Frequency :2.66GHz FSB Speed :1333 MHz Cache L1 :64 KB Cache L2 :4096 KB Ratio Status:Unlocked (Min:06, Max:08) Ratio Actual Value: 8
Sets the ratio between CPU Core Clock and the FSB Frequency. Note:If an invalid ratio is set in CMOS then actual and setpoint values may differ.
Ratio CMOS Setting [7] C1E Support [Enabled] Hardware Prefetcher [Enabled] Adjacent Cache Line Prefetch [Enabled] Max CPUID Value Limit [Disabled] Intel(R) Virtualization Tech [Enabled] Execute-Disable Bit Capability [Enabled] Core Multi-Processing [Enabled]
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Scroll down for more items.
Intel(R) SpeedStep(tm) tech. [Enabled]
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Ratio CMOS Setting [7] Whether this item is configurable depends on your CPU type. The valid value ranges differently according to your CPU type. If this item is configurable, enter the value using the numeric keypad. This item is available only when Intel SpeedStep technology is disabled.
Allows you to enable or disable C1E support. Configuration options: [Disabled] [Enabled]
Enable this item to use the Hardware Prefetcher Disable Feature. Configuration options: [Disabled] [Enabled]
Enable this item to use the Adjacent Cache Line Prefetch Disable Feature. Configuration options: [Disabled] [Enabled]
![Page 90 of the Asus TS500-E5 user manual — Intel(R) SpeedStep(tm) tech. [Enabled]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-90.webp?w=400)
Setting this item to [Enabled] allows legacy operating systems to boot even without support for CPUs with extended CPUID functions. Configuration options: [Disabled] [Enabled]
The Vanderpool Virtualization Technology allows a hardware platform to run multiple operating systems separately, enabling one system to virtually function as several systems. Configuration options: [Disabled] [Enabled]
Allows you to enable or disable the No-Execution Page Protection Technology. Setting this item to [Disabled] forces the XD feature flag to always return to zero (0). Configuration options: [Disabled] [Enabled]
Allows you to enable or disable the Intel SpeedStep Technology. Refer to the Appendix for more information on the Intel SpeedStep Technology. Configuration options: [Disabled] [Enabled]
Items above with * mark are for technical personnel to debug only.
![Page 91 of the Asus TS500-E5 user manual — MCH Channel Mode [Channel Interleave]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-91.webp?w=400)
The Chipset configuration menu allows you to change advanced chipset settings. Select an item then press to display the sub-menu.
BIOS SETUP UTILITY Advanced
Configure North Bridge features.
←→ Select Screen ↑↓ Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
The North Bridge Configuration menu allows you to change the Northbridge settings.
BIOS SETUP UTILITY Advanced
Crystal Beach / DMA [Disabled]
Crystal Beach / DMA configuration
MCH Channel Mode [Channel Interleave] Patrol Scrubbing [Enabled] Demand Scrubbing [Enabled] Channel Dependent Sparing [Disabled] Channel 0 [Enabled] Channel Specific Sparing [Disabled] Rank Interleaving [4:1] Channel 1 [Enabled] Channel Specific Sparing [Disabled] Rank Interleaving [4:1] Read Completion Coalescing [Auto]
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Allows you to do the Crystal Beach/DMA configuration. Configuration options: [Disabled] [Enabled]
Allows you to select the MCH channel mode. Configuration options: [Channel Sequencing] [Channel Interleave] [Single Channel 0]
Advanced Chipset Settings · North Bridge Configuration
![Page 92 of the Asus TS500-E5 user manual — Read Completion Coalescing [Auto]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-92.webp?w=400)
Enables or disables the Patrol Scrubbing. Configuration options: [Disabled] [Enabled]
Enables or disables the Demand Scrubbing. Configuration options: [Disabled] [Enabled]
Allows you to enable or disabled the channel-dependent DIMM sparing feature. Configuration options: [Disabled] [Enabled]
Allows you to enable or disable the Channel 0. If you set this item to [Disabled], the following three items will be grayed out. Configuration options: [Disabled] [Enabled]
Allows you to enable or disable the DIMM sparing feature. Configuration options: [Disabled] [Enabled]
Allows you to select the Channel 0 Rank Interleave. Configuration options: [1:1] [2:1] [4:1]
Allows you to enable or disable the Channel 1. If you set this item to [Disabled], Channel 0 and the following two items will be grayed out. Configuration options: [Disabled] [Enabled]
Allows you to enable or disable the DIMM sparing feature. Configuration options: [Disabled] [Enabled]
Allows you to select the Channel 1 Rank Interleave. Configuration options: [1:1] [2:1] [4:1]
![Page 93 of the Asus TS500-E5 user manual — Onboard LAN1/2 Boot ROM [Enabled]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-93.webp?w=400)
BIOS SETUP UTILITY Advanced
Configure Win627EHF Super IO Chipset
Allows BIOS to Enable or Disable Floppy Controller.
Serial Port1 Address [3F8/IRQ4] Serial Port2 Address [2F8/IRQ3] Serial Port2 Mode [Normal]
OnBoard LAN1 Boot ROM [Enabled] OnBoard LAN2 Boot ROM [Enabled]
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Allows you to select the Serial Port1 base address. Configuration options: [Disabled] [3F8/IRQ4] [3E8/IRQ4] [2E8/IRQ3]
Allows you to select the Serial Port2 base address. Configuration options: [Disabled] [2F8/IRQ3] [3E8/IRQ4] [2E8/IRQ3]
Serial Port2 Mode [Normal]
Allows you to select the mode for Serial Port2. Configuration options: [Normal] [IrDA] [ASK IR]
IR I/O Pin Select [SINB/SOUTB] This item appears only when you set the Serial Port2 Mode item to [IrDa] or [ASK IR] and allows you to select the receiver or transmit pin for Serial Port2. Configuration options: [SINB/SOUTB] [IRRX/IRTX]
IR Duplex Mode [Half Duplex] This item appears only when you set the Serial Port2 Mode item to [IrDa] or [ASK IR] and allows you to select Full or Half Duplex for Serial Port2. Configuration options: [Full Duplex] [Half Duplex]
Allows you to do the LAN Boot ROM configuration. Configuration options: [Disabled] [Enabled]
![Page 94 of the Asus TS500-E5 user manual — Palette Snooping [Disabled]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-94.webp?w=400)
The PCIPnP menu items allow you to change the advanced settings for PCI/PnP devices. The menu includes setting IRQ and DMA channel resources for either PCI/PnP or legacy ISA devices, and setting the memory size block for legacy ISA devices.
Take caution when changing the settings of the PCI/PnP Configuration menu items. Incorrect field values can cause the system to malfunction.
BIOS SETUP UTILITY Advanced
NO: lets the BIOS configure all the devices in the system. YES: lets the operating system configure Plug and Play (PnP) devices not required for boot if your system has a Plug and Play operating system.
Plug & Play O/S [No] PCI Latency Timer [64] Allocate IRQ to PCI VGA [Yes] Palette Snooping [Disabled]
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
When set to [No], BIOS configures all the devices in the system. When set to [Yes] and if you install a Plug and Play operating system, the operating system configures the Plug and Play devices not required for boot. Configuration options: [No] [Yes]
Allows you to select the value in units of PCI clocks for the PCI device latency timer register. Configuration options: [32] [64] [96] [128] [160] [192] [224] [248]
When set to [Yes], BIOS assigns an IRQ to PCI VGA card if the card requests for an IRQ. When set to [No], BIOS does not assign an IRQ to the PCI VGA card even if requested. Configuration options: [Yes] [No]
When set to [Enabled], the pallete snooping feature informs the PCI devices that an ISA graphics device is installed in the system so that the latter can function correctly. Configuration options: [Disabled] [Enabled]
Advanced PCI/PnP Settings
![Page 95 of the Asus TS500-E5 user manual — Remote Access [Enabled]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-95.webp?w=400)
BIOS SETUP UTILITY Main Advanced Server Power Boot Exit
Configure Remote Access.
ASF Support [Enabled] Remote Access Configuration
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Allows you to enable or disable the ASF support. Configuration options: [Disabled] [Enabled]
The items in this menu allows you to configure the Remote Access features. Select an item then press to display the configuration options.
BIOS SETUP UTILITY Server
Configure Remote Access type and parameters
Select Remote Access type.
Serial port number [COM2] Base Address, IRQ [2F8h, 3] Serial Port Mode [57600 8,n,1] Flow Control [Hardware] Redirection After BIOS POST [Disabled] Terminal Type [VT-UTF8] Sredir Memory Display Delay [No Delay]
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Enables or disables the remote access feature. Configuration options: [Disabled] [Enabled]
The following items appear only when Remote Access is set to [Enabled].
Remote Access [Enabled]
![Page 96 of the Asus TS500-E5 user manual — Sredir Memory Display Delay [No Delay]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-96.webp?w=400)
Selects the serial port for console redirection. Configuration options: [COM1] [COM2]
Base Address. IRQ [2F8h, 3] This item is not user-configurable and changes with the configuration of Serial port number.
Sets the Serial port mode. Configuration options: [115200 8,n,1] [57600 8,n,1] [38400 8,n,1] [19200 8,n,1]
Allows you to select the flow control for console redirection. Configuration options: [None] [Hardware] [Software]
Sets the redirection mode after the BIOS Power-On Self-Test (POST). Some operating system may not work when set to [Always]. Configuration options: [Disabled] [Boot Loader] [Always]
Allows you to select the target terminal type. Configuration options: [ANSI] [VT100] [VT-UTF8]
Enables or disables the VT-UTF8 combo key support for ANSI or VT100 terminals. Configuration options: [Disabled] [Enabled]
Sets the delay seconds to display memory information. Configuration options: [No Delay] [Delay 1 Sec] [Delay 2 Sec] [Delay 4 Sec]
![Page 97 of the Asus TS500-E5 user manual — 5.6.2 ACPI APIC Support [Enabled]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-97.webp?w=400)
The Power menu items allow you to change the settings for the Advanced Power Management (APM). Select an item then press to display the configuration options.
BIOS SETUP UTILITY Main Advanced Server Power Boot Exit
Add additional tables as per ACPI 2.0 specifications.
ACPI 2.0 Support [Disabled] ACPI APIC Support [Enabled]
APM Configuration Hardware Monitor
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Specifies the Advanced Configuration and Power Interface (ACPI) version supported. Configuration options: [Disabled] [Enabled]
Allows you to enable or disable the Advanced Configuration and Power Interface (ACPI) support in the Advanced Programmable Interrupt Controller (APIC). When set to Enabled, the ACPI APIC table pointer is included in the RSDT pointer list. Configuration options: [Disabled] [Enabled]
![Page 98 of the Asus TS500-E5 user manual — Resume On RTC Alarm [Disabled]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-98.webp?w=400)
BIOS SETUP UTILITY Power
<Enter> to select whether or not to restart the system after AC power loss
Restore on AC Power Loss [Last State] Power On By External Modems [Disabled] Power On by PME [Disabled] Power On By RTC Alarm [Disabled]
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
When set to [Power Off], the system goes into off state after an AC power loss. When set to [Power On], the system will reboot after an AC power loss. When set to [Last State], the system goes into either off or on state, whatever the system state was before the AC power loss. Configuration options: [Power Off] [Power On] [Last State]
This allows either settings of [Enabled] or [Disabled] for powering up the computer when the external modem receives a call while the computer is in Soft-off mode. Configuration options: [Disabled] [Enabled]
Setting this item to [Enabled] allows the computer to power up even when the Serial Port1/2 Address item in the Onboard Device Configuration menu is set to [Disabled]. See section 5.4.4 Onboard Device Configuration for details.
When set to [Enabled], the system enables the PME to generate a wake event while the computer is in Soft-off mode. Configuration options: [Disabled] [Enabled]
Allows you to enable or disable RTC to generate a wake-up event. Configuration options: [Disabled] [Enabled]

BIOS SETUP UTILITY Power
Hardware Temperature Configuration Hardware Fan Configuration Hardawre Voltage Configuration
←→ Select Screen ↑↓ Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
The Hardware Temperature Configuration menu provides an overview of the hardware temperature information. The BIOS automatically detects the items in this menu.
CPU1/CPU2 [xxxºC/xxxºF] System1/2 [xxxºC/xxxºF]
The onboard hardware monitor automatically detects and displays the motherboard and CPU temperatures. The CPU1 Temperature shows N/A if no processor is installed in CPU1 socket.
The Hardware Fan Configuration menu provides an overview of the hardware fan information. The BIOS automatically detects the items in this menu.
CPU FAN1/2; FRN FAN1/2/3/4; REAR FAN1/2 [xxxxRPM] or [N/A]
The onboard hardware monitor automatically detects and displays the CPU, front, and rear fan speed in rotations per minute (RPM). If the fan is not connected to the motherboard, the field shows N/A.
The Hardware Voltage Configuration menu provides an overview of the hardware fan information. The BIOS automatically detects the items in this menu.
VCOREA/B, Vtt, VSEN1/2, 3VSEN, 12VSEN, 5VDD, 5VSB, VBAT
The onboard hardware monitor automatically detects the voltage output through the onboard voltage regulators.
Hardware Monitor
![Page 100 of the Asus TS500-E5 user manual — 1st ~ xxth Boot Device [XXXXXXX]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-100.webp?w=400)
The Boot menu items allow you to change the system boot options. Select an item then press to display the sub-menu.
BIOS SETUP UTILITY Main Advanced Server Power Boot Exit
Specifies the Boot Device Priority sequence.
Boot Settings Configuration Security
A virtual floppy disk drive (Floppy Drive B: ) may appear when you set the CD-ROM drive as the first boot device.
←→ Select Screen ↑↓ Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
BIOS SETUP UTILITY Main Advanced Server SecuritBoot Exit
Specifies the Boot Device Priority sequence.
1st Boot Device [1st FLOPPY DRIVE] 2nd Boot Device [ATAPI CD-ROM] 3rd Boot Device [Network:MBA v10.0.] 4th Boot Device [Network:MBA v10.0.]
A device enclosed in parenthesis has been disabled in the corresponding type menu.
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
These items specify the boot device priority sequence from the available devices. The number of device items that appears on the screen depends on the number of devices installed in the system. Configuration options: [xxxxx Drive] [Disabled]
Boot Device Priority · Boot Device Priority
![Page 101 of the Asus TS500-E5 user manual — Hit ‘DEL‘ Message Display [Enabled]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-101.webp?w=400)
BIOS SETUP UTILITY Main Advanced Server Security Boot Exit
Allows BIOS to skip certain tests while booting. This will decrease the time needed to boot the system.
Quick Boot [Enabled] Full Screen Logo [Enabled] AddOn ROM Display Mode [Force BIOS] Bootup Num-Lock [On] PS/2 Mouse Support [Auto] Wait For ‘F1‘ If Error [Enabled] Hit ‘DEL‘ Message Display [Enabled] Interrupt 19 Capture [Enabled]
←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Enabling this item allows the BIOS to skip some power on self tests (POST) while booting to decrease the time needed to boot the system. When set to [Disabled], BIOS performs all the POST items. Configuration options: [Disabled] [Enabled]
Allows you to enable or disable the full screen logo display feature. Configuration options: [Disabled] [Enabled]
Set this item to [Enabled] to use the ASUS MyLogo2™ feature.
Allows you to set the display mode for Options ROM. Configuration options: [Force BIOS] [Keep Current]
Allows you to select the power-on state for the NumLock. Configuration options: [Off] [On]
Allows you to enable or disable support for PS/2 mouse. Configuration options: [Disabled] [Enabled] [Auto]
When set to [Enabled], the system waits for the key to be pressed when error occurs. Configuration options: [Disabled] [Enabled]
When set to [Enabled], the system displays the message “Press DEL to run Setup” during POST. Configuration options: [Disabled] [Enabled]
Boot Settings Configuration

When set to [Enabled], this function allows the option ROMs to trap Interrupt 19. Configuration options: [Disabled] [Enabled]
The Security menu items allow you to change the system security settings. Select an item then press to display the configuration options.
BIOS SETUP UTILITY Main Advanced Server Power Boot Tools Exit
<Enter> to change password. <Enter> again to disable password.
Change Supervisor Password Change User Password
←→ Select Screen ↑↓ Select Item Enter Change F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Select this item to set or change the supervisor password. The Supervisor Password item on top of the screen shows the default Not Installed. After you set a password, this item shows Installed.
To set a Supervisor Password:
The message “Password Installed” appears after you successfully set your password.
To change the supervisor password, follow the same steps as in setting a user password.
To clear the supervisor password, select the Change Supervisor Password then press . The message “Password Uninstalled” appears.
If you forget your BIOS password, you can clear it by erasing the CMOS Real Time Clock (RTC) RAM. See section 4.2 Jumper for information on how to erase the RTC RAM.
Security Settings
![Page 103 of the Asus TS500-E5 user manual — Password Check [Setup]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-103.webp?w=400)
After you have set a supervisor password, the other items appear to allow you to change other security settings.
BIOS SETUP UTILITY Main Advanced Server Power Boot Tools Exit
<Enter> to change password. <Enter> again to disable password.
Change Supervisor Password User Access Level [Full Access] Change User Password Password Check [Setup]
This item allows you to select the access restriction to the Setup items. Configuration options: [No Access] [View Only] [Limited] [Full Access]
No Access prevents user access to the Setup utility.
View Only allows access but does not allow change to any field.
Limited allows changes only to selected fields, such as Date and Time.
Full Access allows viewing and changing all the fields in the Setup utility.
Select this item to set or change the user password. The User Password item on top of the screen shows the default Not Installed. After you set a password, this item shows Installed.
To set a User Password:
The message “Password Installed” appears after you set your password successfully.
To change the user password, follow the same steps as in setting a user password.
When set to [Setup], BIOS checks for user password when accessing the Setup utility. When set to [Always], BIOS checks for user password both when accessing Setup and booting the system. Configuration options: [Setup] [Always]

The Exit menu items allow you to load the optimal or failsafe default values for the BIOS items, and save or discard your changes to the BIOS items.
BIOS SETUP UTILITY Main Advanced Server Power Boot Exit
Exit system setup after saving the changes.
Exit & Save Changes Exit & Discard Changes Discard Changes
F10 key can be used for this operation.
←→ Select Screen ↑↓ Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit
v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
Pressing does not immediately exit this menu. Select one of the options from this menu or from the legend bar to exit.
Once you are finished making your selections, choose this option from the Exit menu to ensure the values you selected are saved to the CMOS RAM. An onboard backup battery sustains the CMOS RAM so it stays on even when the PC is turned off. When you select this option, a confirmation window appears. Select YES to save changes and exit.
If you attempt to exit the Setup program without saving your changes, the program prompts you with a message asking if you want to save your changes before exiting. Press to save the changes while exiting.
Select this option only if you do not want to save the changes that you made to the Setup program. If you made changes to fields other than System Date, System Time, and Password, the BIOS asks for a confirmation before exiting.
This option allows you to discard the selections you made and restore the previously saved values. After selecting this option, a confirmation appears. Select YES to discard any changes and load the previously saved values.
This option allows you to load the default values for each of the parameters on the Setup menus. When you select this option or if you press , a confirmation window appears. Select YES to load default values. Select Exit & Save Changes or make other changes before saving the values to the non-volatile RAM.
Exit Options · Load Setup Defaults

RAID configuration
This chapter provides instructions for setting up, creating and configuring RAID sets using the available utilities.

The motherboard comes with the following RAID solutions:
RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a sustained data transfer rate, double that of a single disk alone, thus improving data access and storage. Use of two new identical hard disk drives is required for this setup.
RAID 1 (Data mirroring) copies and maintains an identical image of data from one drive to a second drive. If one drive fails, the disk array management software directs all applications to the surviving drive as it contains a complete copy of the data in the other drive. This RAID configuration provides data protection and increases fault tolerance to the entire system. Use two new drives or use an existing drive and a new drive for this setup. The new drive must be of the same size or larger than the existing drive.
RAID 10 is data striping and data mirroring combined without parity (redundancy data) having to be calculated and written. With the RAID 10 configuration you get all the benefits of both RAID 0 and RAID 1 configurations. Use four new hard disk drives or use an existing drive and three new drives for this setup.
RAID 5 stripes both data and parity information across three or more hard disk drives. Among the advantages of RAID 5 configuration include better HDD performance, fault tolerance, and higher storage capacity. The RAID 5 configuration is best suited for transaction processing, relational database applications, enterprise resource planning, and other business systems. Use a minimum of three identical hard disk drives for this setup.
Intel® Matrix Storage. The Intel® Matrix Storage technology supported by the ICH9R chip allows you to create a RAID 0, RAID 1, RAID 5, and RAID 10* function to improve both system performance and data safety. You can also combine two RAID sets to get higher performance, capacity, or fault tolerance provided by the difference RAID function. For example, RAID 0 and RAID 1 set can be created by using only two identical hard disk drives.
If you want to boot the system from a hard disk drive included in a created RAID set, copy first the RAID driver from the support CD to a floppy disk before you install an operating system to the selected hard disk drive.

The motherboard supports Serial ATA for RAID set configuration. For optimal performance, install identical drives of the same model and capacity when creating a disk array.
To install the SATA hard disks for RAID configuration:
You must set the RAID item in the BIOS Setup before you can create a RAID set from SATA hard disk drives attached to the SATA connectors supported by the Intel
® ICH9R Southbridge chip. To do this:
Refer to Chapter 5 for details on entering and navigating through the BIOS Setup.
Depending on the RAID connectors that you use, you can create a RAID set using the utilities embedded in each RAID controller. For example, use the LSI Software RAID Configuration Utility or the Intel
® Matrix Storage Manager if you installed Serial ATA hard disk drives on the Serial ATA connectors supported by the Intel
® ICH9R Southbridge.
Refer to the succeeding sections for details on how to use each RAID configuration utility.

The LSI Software RAID Configuration Utility allows you to create RAID 0, RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard Southbridge chip.
To enter the LSI Software RAID Configuration Utility:
LSI MegaRAID Software RAID BIOS Version A.01 08131852R LSI SATA RAID Found at PCI Bus No: Dev No:1F Device present at Port 0 HDS722512VLSA80 117800MB Device present at Port 1 HDS722512VLSA80 117800MB
Press Ctrl-M or Enter to run LSI Software RAID Setup Utility.
At the bottom of the screen is the legend box. The keys on the legend box allow you to navigate through the setup menu options or execute commands. The keys on the legend box vary according to the menu level.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Management Menu Configure Initialize Objects Rebuild Check Consistency
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
Configure VD(s)

Configure Allows you to create RAID 0, RAID 1 or RAID 10 set using the Easy Configuration or the New Configuration command. This menu also allows you to view, add, or clear RAID configurations or select the boot drive
Initialize Allows you to initialize the logical drives of a created RAID set
Objects Allows you to initialize logical drives or change the logical drive parameters
Rebuild Allows you to rebuild failed drives
Check Consistency Allows you to check the data consistency of the logical drives of a
The LSI Software RAID Configuration Utility allows you to create a RAID 0 or RAID 1 set using two types of configurations: Easy and New.
In Easy Configuration, the logical drive parameters are set automatically including the size and stripe size (RAID 1 only).
In New Configuration, you manually set the logical drive parameters and assign the set size and stripe size (RAID 1 only).
To create a RAID set using the Easy Configuration option:
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Management Menu Configure Initialize Objects Rebuild Check Consistency
Defines Physical Arrays. An Array Will Automatically Become A VD
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
Menu Description · created RAID set

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
READY
READY
Port # 0 DISK 77247MB HDS728080PLA380 PF20A60A
The information of the selected hard disk drive displays at the bottom of the screen.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
ONLIN A00-00
ONLIN A00-01
Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A
SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP · SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
A-0 SPAN-1
DNLIN A00-00
DNLIN A00-01
Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit
Press again, the logical drive information appears including a Logical Drive menu that allows you to change the logical drive parameters.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
PORT #
DNLIN A00-00
DNLIN A00-01
Logical Drive 0 RAID = 1 Size = 77247MB DWC = Off RA = On Accept SPAN = NO
Choose RAID Level For This VD
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Select Configurable Array(s)


You need at least two identical hard disk drives when creating a RAID 1 set.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Logical Drive 0 RAID = 1 Size = 77247MB DWC = Off RA = On Accept SPAN = NO
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
When creating a RAID 0 set, proceed to step 10.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Logical Drive 0 RAID = 1 Size = 77247MB DWC = Off RA = On Accept SPAN = NO
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Enabling DWC can improve the performance, but with the risk of data loss.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
PORT #
DNLIN A00-00
DNLIN A00-01
Logical Drive 0 RAID = 1 Size = 77247MB DWC = Off RA = On Accept SPAN = NO
Accept This VD Configuration And Go To Next VD
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Save Configuration? Yes No
Management Menu Configure Initialize Objects Rebuild Check Consistency
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Select Yes Or No
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

When a RAID set is already existing, using the New Configuration command erases the existing RAID configuration data. If you do not want to delete the existing RAID set, use the View/Add Configuration command to view or create another RAID configuration.
To create a RAID set using the New Configuration option:
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Management Menu Configure Initialize Objects Rebuild Check Consistency
Clear Existing Configuration And Start A New Configuration
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
PORT #
DNLIN A00-00
DNLIN A00-01
Logical Drive 0 RAID = 1 Size = 77247MB DWC = Off RA = On Accept SPAN = NO
Enter VD Size (MB):
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

You can create a RAID 10 set using four identical hard disk drives.
To create a RAID 10 set using the Easy Configuration option:
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Management Menu Configure Initialize Objects Rebuild Check Consistency
Defines Physical Arrays. An Array Will Automatically Become A VD
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
READY
READY
READY
READY
Port # 0 DISK 77247MB HDS728080PLA380 PF20A60A
The information of the selected hard disk drive displays at the bottom of the screen.
SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
ONLIN A00-00
ONLIN A00-01
ONLIN A00-02
ONLIN A00-03
Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
A-0 SPAN-1
DNLIN A00-00
DNLIN A00-01
Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit
SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP · Select Configurable Array(s)

Press again, the logical drive information appears including a Logical Drive menu that allows you to change the logical drive parameters.

You need at least four identical hard disk drives when creating a RAID 10 set.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Logical Drive 0 RAID = 0 Size = 308988MB DWC = Off RA = On Accept SPAN = NO
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Logical Drive 0 RAID = 1 Size = 154494MB DWC = Off RA = On Accept SPAN = NO
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
PORT #
DNLIN A00-00
DNLIN A00-01
Logical Drive 0 RAID = 10 Size = 308988MB DWC = Off RA = On Accept SPAN = NO
Accept This VD Configuration And Go To Next VD
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Save Configuration? Yes No
Management Menu Configure Initialize Objects Rebuild Check Consistency
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Select Yes Or No
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

You can add a new RAID configuration or view an existing configuration using the View/Add Configuration command.
To add a new RAID configuration:
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Management Menu Configure Initialize Objects Rebuild Check Consistency
View/Add to The Existing Configuration
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
READY
READY
Port # 0 DISK 77247MB HDS728080PLA380 PF20A60A
The information of the selected hard disk drive displays at the bottom of the screen.
SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
ONLIN A00-00
ONLIN A00-01
ONLIN A01-00
ONLIN A01-01
Port # 3 DISK 77247MB HDS728080PLA380 PF20A60A
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
View/Add Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
A-0 SPAN-1
DNLIN A00-00
DNLIN A00-01
Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit
SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP · Select Configurable Array(s)

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Easy Configuration - ARRAY SELECTION MENU
Management Menu Configure Initialize Objects Rebuild Check Consistency
0 0 154494MB 2 64 KB ONLINE 0 1 77247MB 2 64 KB ONLINE
DNLIN A00-00
DNLIN A00-01
Logical Drive 1 RAID = 1 Size = 77247MB DWC = Off RA = On Accept SPAN = NO
RAID Level RAID 0 RAID 1
Choose RAID Level For This VD
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Save Configuration? Yes No
Management Menu Configure Initialize Objects Rebuild Check Consistency
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
0 0 154494MB 2 64 KB ONLINE 1 1 77247MB 2 64 KB ONLINE
Select Yes Or No
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

After creating the RAID set(s), you must initialize the logical drives. You may initialize the logical drives of a RAID set(s) using the Initialize or Objects command on the Management Menu.
To initialize the logical drive using the Initialize command:
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Management Menu Configure Initialize Objects Rebuild Check Consistency
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Management Menu Configure Initialize Objects Rebuild Check Consistency
Logical Drives Loical Drive 0
Initialize Logical Drive(s) · Select VD · SPACE-(De)Select, F10-Check Consistency

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Management Menu Configure Initialize Objects Rebuild Check Consistency
Logical Drives Loical Drive 0
Initilize Will Destroy Data On Selected VD(s)
Initializing a logical drive(s) erases all data on the drive.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Management Menu Configure Initialize Objects Rebuild Check Consistency
Initialization Of LD Is In Process
LD 0 Initialization. Press Esc to Abort.
¦ 85 % Completed
Logical Drives Loical Drive 0
Initialize? Yes No · SPACE-(De)Select, F10-Check Consistency · SPACE-(De)Select, F10-Initialize

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Management Menu Configure Initialize Objects Rebuild Check Consistency
Initialization Of LD Is In Process
LD 0 Initialization Complete. Press Esc..
¦ 100 % Completed
Logical Drives Loical Drive 0
To initialize the logical drives using the Objects command:
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Management Menu Configure Initialize Objects Rebuild Check Consistency
Configure Objects Like Adapter Parameters
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
SPACE-(De)Select, F10-Initialize

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Objects Adapter Virtual Drive Physical Drive
Management Menu Configure Initialize Objects Rebuild Check Consistency
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Vitual Drive(1) Logical Drive 0
Objects Adapter Virtual Drive Physical Drive
Management Menu Configure Initialize Objects Rebuild Check Consistency
Press ENTER To Select A VD, <DEL> To Delete A VD
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Vitual Drive(1) Logical Drive 0
Objects Adapter Virtual Drive Physical Drive
Management Menu Configure Initialize Objects Rebuild Check Consistency
Initialze Check Consistency View/Update Parameters
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option


LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

You can manually rebuild failed hard disk drives using the Rebuild command in the Management Menu.
To rebuild a failed hard disk drive:
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Management Menu Configure Initialize Objects Rebuild Check Consistency
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Management Menu Configure Initialize Objects Rebuild Check Consistency
ONLIN A00-00
FAIL A00-01
Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A
Rebuild PD(s) · SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Management Menu Configure Initialize Objects Rebuild Check Consistency
ONLIN A00-00
RBLD A00-01
Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Logical Drives
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Management Menu Configure Initialize Objects Rebuild Check Consistency
ONLIN A00-00
RBLD A00-01
Rebuilding Of Drive Will Take A Few Minutes. Start Rebuilding Drive (Y/N)?
Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Logical Drives

You can check and verify the accuracy of data redundancy in the selected logical drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects > Adapter menu.
The Check Consistency command is available only for logical drives included in a RAID 1 set.
To check data consistency using the Check Consistency command:
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Management Menu Configure Initialize Objects Rebuild Check Consistency
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Management Menu Configure Initialize Objects Rebuild Check Consistency
Logical Drives Loical Drive 0
CC Of VD(s) · Select VD · SPACE-(De)Select, F10-Check Consistency

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Management Menu Configure Initialize Objects Rebuild Check Consistency
Consistency Check? Yes No
Logical Drives Loical Drive 0
A progress bar appears on screen.
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status
Management Menu Configure Initialize Objects Rebuild Check Consistency
VD 0 Consistency Check. Press Esc to Abort.
¦ 85 % Completed
Logical Drives Loical Drive 0
The Data On The Drives Is Inconsistency. Repair Done!
percentage of disk checked, When you restart checking, it continues from the last percentage completed rather than from zero percent.
continues from zero percent.

To check data consistency using the Objects command:

To delete a RAID configuration:
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Management Menu Configure Initialize Objects Rebuild Check Consistency
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Management Menu Configure Initialize Objects Rebuild Check Consistency
Clear Configuration? Yes No
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
The utility clears the current array.
Clear Existing Configuration · Clear Existing Configuration

You must have created a new RAID configuration before you can select the boot drive from a RAID set. Refer to the Creating a RAID set: Using New Configuration section for details.
To select the boot drive from a RAID set:
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Management Menu Configure Initialize Objects Rebuild Check Consistency
Select A Boot VD
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Bootable VDs(1):Current Boot VD(0) Boot Drive 0
Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive
Management Menu Configure Initialize Objects Rebuild Check Consistency
Select A Boot VD
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

You may enable the RAID controller’s WriteCache option to improve the data transmission performance.
When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives.
To enable WriteCache:
LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007
Adapter 0 Rebuild Rate = 30 Chk Const Rate = 30 FGI Rate = 30 BGI Rate = 30 Disk WC = Off Read Ahead = On Bios State = Enable Stop On Error = No Fast Init = Enable Auto Rebuild = On Auto Resume = Enable Disk Coercion = 1GB Factory Default
Objects Adapter Virtual Drive Physical Drive
Management Menu Configure Initialize Objects Rebuild Check Consistency
Disk Write Cache - Off(Write Through) or On(Write Back)
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
![Page 135 of the Asus TS500-E5 user manual — [ DISK/VOLUME INFORMATION ]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-135.webp?w=400)
® Matrix Storage Manager Option ROM Utility
® Matrix Storage Manager Option ROM utility allows you to create RAID 0, RAID 1, RAID 10, and RAID 5 set(s) from Serial ATA hard disk drives.
To enter the Intel
® Matrix Storage Manager Option ROM Utility:
Intel(R) Matrix Storage Manager Option ROM v7.6.0.1011 ICH9R wRAID5
Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.
RAID Volumes: None defined.
Physical Disks: Port Drive Model Serial # Size Type/Status(Vol ID) 0 XXXXXXXXXXX XXXXXXXX XX.XXGB Non-RAID Disk 1 XXXXXXXXXXX XXXXXXXX XX.XXGB Non-RAID Disk 2 XXXXXXXXXXX XXXXXXXX XX.XXGB Non-RAID Disk 3 XXXXXXXXXXX XXXXXXXX XX.XXGB Non-RAID Disk
[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu
The navigation keys at the bottom of the screen allow you to move through the menus and select the menu options.
The RAID setup screens shown in this section are for reference only and may not exactly match the items on your screen due to the controller version difference.
The utility supports maxium four hard disk drives for RAID configurration.
The Intel
![Page 136 of the Asus TS500-E5 user manual — [ SELECT DISKS ]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-136.webp?w=400)
To create a RAID 0 set:
Intel(R) Matrix Storage Manager Option ROM v7.6.0.1011 ICH9R wRAID5
Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.
Volume0 RAID0(Stripe) Select Disks 128KB 0.0 GB
Capacity:
Enter a string between 1 and 16 characters in length that can be used to uniquely identify the RAID volume. This name is case sensitive and cannot
contain special characters.
[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu
Port Drive Model Serial # Size Status 0 XXXXXX XXXXXX XX.XGB Non-RAID Disk 1 XXXXXX XXXXXX XX.XGB Non-RAID Disk 2 XXXXXX XXXXXX XX.XGB Non-RAID Disk 3 XXXXXX XXXXXX XX.XGB Non-RAID Disk
Select 2 to 4 disks to use in creating the volume.
[↑↓]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete
Create Volume

A lower stripe size is recommended for server systems. A higher stripe size is recommended for multimedia computer systems used mainly for audio and video editing.
Are you sure you want to create this volume? (Y/N):
![Page 138 of the Asus TS500-E5 user manual — [ DISK/VOLUME INFORMATION ]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-138.webp?w=400)
To create a RAID 1 set:
Intel(R) Matrix Storage Manager Option ROM v7.6.0.1011 ICH9R wRAID5
Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.
Volume1 RAID1(Mirror) Select Disks N/A 0.0 GB
Capacity:
Enter a string between 1 and 16 characters in length that can be used to uniquely identify the RAID volume. This name is case sensitive and cannot
contain special characters.
[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu
Create Volume
![Page 139 of the Asus TS500-E5 user manual — [ DISK/VOLUME INFORMATION ]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-139.webp?w=400)
To create a RAID 10 set:
Intel(R) Matrix Storage Manager Option ROM v7.6.0.1011 ICH9R wRAID5
Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.
Volume1 RAID10(RAID0+1) Select Disks 128KB 0.0 GB
Capacity:
Enter a string between 1 and 16 characters in length that can be used to uniquely identify the RAID volume. This name is case sensitive and cannot
contain special characters.
[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu
Create Volume
![Page 140 of the Asus TS500-E5 user manual — [ DISK/VOLUME INFORMATION ]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-140.webp?w=400)
To create a RAID 5 set:
Intel(R) Matrix Storage Manager Option ROM v5.6.2.1002 ESB2 wRAID5
Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.
Volume1 RAID5(Parity) Select Disks 128KB 0.0 GB
Capacity:
Enter a string between 1 and 16 characters in length that can be used to uniquely identify the RAID volume. This name is case sensitive and cannot
contain special characters.
[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu
Create Volume
![Page 141 of the Asus TS500-E5 user manual — [ DELETE VOLUME VERIFICATION ]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-141.webp?w=400)
Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set.
To delete a RAID set:
Intel(R) Matrix Storage Manager Option ROM v7.6.0.1011 ICH9R wRAID5
Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.
Name Level Drives Capacity Status Bootable Volume0 RAIDX(xxxxx) X XXX.XGB Normal Yes
Deleting a volume will destroy the volume data on the drive(s) and
cause any member disks to become available as non-RAID disks.
NON-RECOVERABLE.
[↑↓]-Select [<ESC>]-Previous Menu [<Del>]-Delete Volume
ALL DATA IN THE VOLUME WILL BE LOST! Are you sure you want to delete volume “VolumeX”? (Y/N):
![Page 142 of the Asus TS500-E5 user manual — [ CONFIRM EXIT ]](/cdn/reader/cb/cbfedddfbf3c02d26a4c18d17f3df6c1943df71d867604ecb5048f26ac692507/images/page-142.webp?w=400)
Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive.
To reset a RAID set hard disk drive:
Resetting RAID data will remove internal RAID structures from the selected RAID disks. By removing these structures, the drive will revert back to a non-RAID disk.
Port Drive Model Serial # Size Status 0 XXXXXXXXXXXX XXXXXXXX XX.XGB Member Disk 1 XXXXXXXXXXXX XXXXXXXX XX.XGB Member Disk Select the disks that should be reset.
[↑↓]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete
® Matrix Storage Manager
To exit the utility:
Are you sure you want to exit? (Y/N):

Driver installation
This chapter provides instructions for installing the necessary drivers for different system components.

After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides instructions on how to install the RAID controller drivers during OS installation.
You may have to use another system to create the RAID driver disk from the system/motherboard support CD or from the Internet.
If you have created RAID sets with the LSI Software RAID configuration utility, the boot priority of the SATA optical disk drive has to be manually adjusted. Otherwise, the system will not boot from the connected SATA ODD.
A floppy disk with the RAID driver is required when installing Windows
® or Red Hat ® Enterprise operating system on a hard disk drive that is included in a RAID set. You can create a RAID driver disk in DOS (using the Makedisk application in the support CD).
To create a RAID driver disk in DOS environment:
Loading FreeDOS FAT KERNEL GO! Press any key to boot from CDROM...
The Makedisk menu appears.
Create Driver Diskette Menu ICH9R INTEL RAID Driver ICH9R LSI RAID Driver Broadcom ASF Firmware Update FreeDOS command prompt

ICH9R INTEL RAID Driver Windows 32 bit Windows 64 bit Back Exit
ICH9R LSI RAID Driver Windows Server 2003 32 bit Windows Server 2003 64 bit RHEL AS4 UP5 32/64 bit RHEL AS4 UP6 32/64 bit RHEL 5 UP1 32/64 bit SLES 9 SP4 32 bit SLES 9 SP4 64 bit SLES 10 SP1 32 bit SLES 10 SP2 64 bit Back Exit
Broadcom ASF Firmware Update TS500-E5 system Back Exit

To create a RAID driver disk in Windows® Server environment:
\Drivers\ICH9R Intel RAID\Driver\makedisk\win32\f6flpy32.exe
The Windows 64-bit OS RAID driver disk for the Intel® Matrix Storage Manager is located in:
\Drivers\ICH9R Intel RAID\Driver\makedisk\win64\f6flpy64.exe
To create a RAID driver disk in Red Hat® Enterprise Linux server environment:
For LSI Logic Embedded SATA RAID Driver:
\Drivers\Intel LSI RAID\Driver\makedisk

® Server OS
® Server OS installation
To install the RAID controller driver when installing Windows
® Server OS:
® Server OS Setup starts.
® Server installation CD. The Windows
Press F6 if you need to install a third party SCSI or RAID driver...
Setup could not determine the type of one or more mass storage devices installed in your system, or you have chosen to manually specify an adapter. Currently, Setup will load support for the following mass storage devices(s):
* To specify additional SCSI adapters, CD-ROM drives, or special disk controllers for use with Windows, including those for which you have a device support disk from a mass storage device manufacturer, press S.
* If you do not have any device support disks from a mass storage device manufacturer, or do not want to specify additional mass storage devices for use with Windows, press ENTER.
S=Specify Additional Device ENTER=Continue F3=Exit

Please insert the disk labeled
Manufacturer-supplied hardware support disk
into Drive A:
* Press ENTER when ready.
® Setup loads the RAID controller drivers from the RAID driver disk. When prompted, press to continue installation.
® Server OS
To install the RAID controller driver on an existing Windows
® Server OS:
® automatically detects the RAID controller and displays a New Hardware Found window. Click Cancel.
® desktop , then select Properties from the menu.

Windows Setup · ENTER=Continue ESC=Cancel F3=Exit


To verify the RAID controller driver installation:
® desktop , then select Properties from the menu.

The screen differs based on the controller.

® Enterprise
To install the Intel
® ICH9R LSI Logic Embedded SATA RAID controller driver when installing Red Hat
® Enterprise OS:
® Installation CD.


When installing a Red Hat 2.4 kernel with a Driver Update Disk (DUD) to a disk drive attached to a LSI HBA, use the command below at the install prompt: linux dd updates.




® Enterprise RAID driver disk to the floppy disk drive, select OK, then press .

The drivers for the RAID controller are installed to the system.

To install the RAID controller driver when installing SuSE Linux OS:





The drivers for the RAID controller are installed to the system.

® chipset device installation
This section provides instructions on how to install the Plug and Play components for the Intel
® chipset on the system.
You need to manually install the Intel
® chipset software on a Windows Server operating system. To install the Intel
® chipset device software:








This section provides instructions on how to install the Broadcom
® Gigabit LAN controller drivers on a Windows
® Server OS.
To install the LAN controller drivers:
® automatically detects the LAN controllers and displays a New Hardware Found window. Click Cancel to close this window.







This section provides instructions on how to install the XGI Volari Z9s Video Graphics Adapter (VGA) driver.
® Server
You need to manually install the XGI Volari Z9s VGA driver on a Windows® Server operating system. To install the XGI Volari Z9s VGA driver:
The Drivers menu if Autorun is enabled in your computer.





The support CD that came with the motherboard package contains the drivers, management applications, and utilities that you can install to avail all motherboard features.
The contents of the support CD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for updates.
Place the support CD to the optical drive. The CD automatically displays the Drivers menu if Autorun is enabled in your computer.
If Autorun is NOT enabled in your computer, browse the contents of the support CD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run the CD.
The Drivers menu shows the available device drivers if the system detects installed devices. Install the necessary drivers to activate the devices.
The screen display and driver options vary under different operating system versions.

The Management Software menu displays the available network and server monitoring applications. Click an item to install.

The Utilities menu displays the software applications and utilities that the motherboard supports. Click an item to install.

Click the Contact tab to display the ASUS contact information. You can also find this information on the inside front cover of this user guide.

Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.