EN
Asus logo
Official user manual

Asus TS500-E5

164 pages·6.8 MB·Personal Computer·PDF·ENDEFRITNLJA
Asus TS500-E5
Table of Contents 136 sections Contents · Notices · Safety information · About this guide · … ShowHide
Contentsp.3Noticesp.7Safety informationp.8About this guidep.9Chapter 1: Product introductionp.111.1 System package contentsp.121.2 Serial number labelp.121.3 System specificationsp.131.4 Front panel featuresp.151.4.1 Four Hot-Swap HDD Devicesp.151.4.2 Eight Hot-Swap HDD Devicesp.161.5 Rear panel featuresp.171.5.1 Single power supply (PA4 model)p.171.5.2 Redundant Power Supply (RX8 model)p.171.6 Internal featuresp.181.7 LED informationp.191.7.1 Front panel LEDsp.191.7.2 Rear panel LEDsp.20Chapter 2: Hardware setupp.212.1 Chassis coverp.222.1.1 Removing the side coverp.222.1.2 Reinstalling the side coverp.232.2 Central Processing Unit (CPU)p.242.2.1 Installing the CPUp.242.2.2 Installing the CPU heatsink and fanp.272.3 System memoryp.282.3.1 Overviewp.282.3.2 Memory configurationsp.282.3.3 Memory mirroring and sparing technologyp.302.3.4 Installing a DIMMp.322.3.5 Removing a DIMMp.322.4 Front panel assemblyp.332.4.1 Removing the front panel assemblyp.332.4.2 Reinstalling the front panel assemblyp.332.5 5.25-inch or 3.5-inch drivesp.342.5.1 Installing a 5.25-inch drivep.342.5.2 Installing a 3.5-inch drivep.352.6 SATA/SAS hard disk drivesp.362.6.1 Hot-swap HDD modulep.362.7 Expansion cardsp.402.7.1 Installing an expansion cardp.402.7.2 Installing ASUS PIKE RAID cardp.412.7.3 Configuring an expansion cardp.422.8 Cable connectionsp.432.8.1 Motherboard connectionsp.432.8.2 SATA/SAS backplane connectionsp.442.9 Removable componentsp.462.9.1 System fanp.462.9.2 Chassis footpadsp.482.9.3 Power supply unitp.49Chapter 3: Installation optionsp.513.1 Preparing the system for rack mountingp.523.2 Attaching the inner rail to the serverp.523.3 Attaching the rails to the rackp.533.4 Mounting the server to the rackp.54Chapter 4: Motherboard Infop.554.1 Motherboard layoutp.564.2 Jumpersp.584.3 Internal connectorsp.63Chapter 5: BIOS setupp.735.1 Managing and updating your BIOSp.745.1.1 Creating a bootable floppy diskp.745.1.2 AFUDOS utilityp.755.1.3 ASUS CrashFree BIOS 3 utilityp.785.2 BIOS setup programp.795.2.1 BIOS menu screenp.805.2.2 Menu barp.805.2.3 Navigation keysp.805.2.4 Menu itemsp.815.2.5 Sub-menu itemsp.815.2.6 Configuration fieldsp.815.2.7 Pop-up windowp.815.2.8 Scroll barp.815.2.9 General helpp.815.3 Main menup.825.3.1 System Time [xx:xx:xx]p.825.3.2 System Date [Day xx/xx/xxxx]p.825.3.3 Legacy Diskette A [Disabled]p.825.3.4 SATA1–6; PATA Master/Slavep.835.3.5 IDE Configurationp.855.3.6 System Informationp.865.4 Advanced menup.875.4.1 USB Configurationp.875.4.2 CPU Configurationp.895.4.3 Chipsetp.915.4.4 Onboard Device Configurationp.935.4.5 PCIPnPp.945.5 Server menup.955.5.1 ASF Support [Enabled]p.955.5.2 Remote Access Configurationp.955.6 Power menup.975.6.1 ACPI 2.0 Support [Disabled]p.975.6.2 ACPI APIC Support [Enabled]p.975.7 Boot menup.1005.7.1 Boot Device Priorityp.1005.7.2 Boot Settings Configurationp.1015.7.3 Securityp.1025.8 Exit menup.104Chapter 6: RAID configurationp.1056.1 Setting up RAIDp.1066.1.1 RAID definitionsp.1066.1.2 Installing hard disk drivesp.1076.1.3 Setting the RAID item in BIOSp.1076.1.4 RAID configuration utilitiesp.1076.2 LSI Software RAID Configuration Utilityp.1086.2.1 Creating a RAID 0 or RAID 1 setp.1096.2.2 Creating a RAID 10 setp.1156.2.3 Adding or viewing a RAID configurationp.1196.2.4 Initializing the logical drivesp.1226.2.5 Rebuilding failed drivesp.1276.2.6 Checking the drives for data consistencyp.1296.2.7 Deleting a RAID configurationp.1326.2.8 Selecting the boot drive from a RAID setp.1336.2.9 Enabling the WriteCachep.1346.3 Intel® Matrix Storage Manager Option ROM Utilityp.1356.3.1 Creating a RAID 0 set (Stripe)p.1366.3.2 Creating a RAID 1 set (Mirror)p.1386.3.3 Creating a RAID 10 set (Stripe + Mirror)p.1396.3.4 Creating a RAID 5 set (Parity)p.1406.3.5 Deleting a RAID setp.1416.3.6 Resetting disks to Non-RAIDp.1426.3.7 Exiting the Intel® Matrix Storage Managerp.142Chapter 7: Driver installationp.1437.1 RAID driver installationp.1447.1.1 Creating a RAID driver diskp.1447.1.2 Installing the RAID controller driverp.1477.2 Intel® chipset device installationp.1557.3 LAN driver installationp.1587.4 VGA driver installationp.1617.4.1 Windows® Serverp.1617.5 Management applications and utilities installationp.1637.5.1 Running the support CDp.1637.5.2 Drivers menup.1637.5.3 Management Software menup.1647.5.4 Utilities menup.1647.5.5 Contact informationp.164
Page 1 of the Asus TS500-E5 user manual — Pedestal/5U Rackmount Server TS500-E5
Page 1 · click to enlarge
Page 1

Pedestal/5U Rackmount Server TS500-E5

User Guide

Asus TS500-E5 — Pedestal/5U Rackmount Server TS500-E5 diagram (page 1)
Fig. 1 · Pedestal/5U Rackmount Server TS500-E5
Page 2 of the Asus TS500-E5 user manual — E3903
Page 2 · click to enlarge
Page 2

E3903

First Edition V1 June 2008

Copyright © 2008 ASUSTeK COMPUTER INC. All Rights Reserved.

No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).

ASUS provides this manual “as is” without warranty of any kind, either express or implied, including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose. In no event shall ASUS, its directors, officers, employees, or agents be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of use or data, interruption of business and the like), even if ASUS has been advised of the possibility of such damages arising from any defect or error in this manual or product.

Specifications and information contained in this manual ae furnished for informational use only, and are subject to change at any time without notice, and should not be construed as a commitment by ASUS. ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual, including the products and software described in it.

Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced or missing.

Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners’ benefit, without intent to infringe.

Page 3 of the Asus TS500-E5 user manual — Table of Contents
Page 3 · Contents
Contents

Contents

Contentsp.3Noticesp.7Safety informationp.8About this guidep.9Chapter 1: Product introductionp.111.1 System package contentsp.121.2 Serial number labelp.121.3 System specificationsp.131.4 Front panel featuresp.151.4.1 Four Hot-Swap HDD Devicesp.151.4.2 Eight Hot-Swap HDD Devicesp.161.5 Rear panel featuresp.171.5.1 Single power supply (PA4 model)p.171.5.2 Redundant Power Supply (RX8 model)p.171.6 Internal featuresp.181.7 LED informationp.191.7.1 Front panel LEDsp.191.7.2 Rear panel LEDsp.20Chapter 2: Hardware setupp.212.1 Chassis coverp.222.1.1 Removing the side coverp.222.1.2 Reinstalling the side coverp.232.2 Central Processing Unit (CPU)p.242.2.1 Installing the CPUp.242.2.2 Installing the CPU heatsink and fanp.272.3 System memoryp.282.3.1 Overviewp.282.3.2 Memory configurationsp.282.3.3 Memory mirroring and sparing technologyp.302.3.4 Installing a DIMMp.322.3.5 Removing a DIMMp.322.4 Front panel assemblyp.332.4.1 Removing the front panel assemblyp.332.4.2 Reinstalling the front panel assemblyp.332.5 5.25-inch or 3.5-inch drivesp.342.5.1 Installing a 5.25-inch drivep.342.5.2 Installing a 3.5-inch drivep.352.6 SATA/SAS hard disk drivesp.362.6.1 Hot-swap HDD modulep.362.7 Expansion cardsp.402.7.1 Installing an expansion cardp.402.7.2 Installing ASUS PIKE RAID cardp.412.7.3 Configuring an expansion cardp.422.8 Cable connectionsp.432.8.1 Motherboard connectionsp.432.8.2 SATA/SAS backplane connectionsp.442.9 Removable componentsp.462.9.1 System fanp.462.9.2 Chassis footpadsp.482.9.3 Power supply unitp.49Chapter 3: Installation optionsp.513.1 Preparing the system for rack mountingp.523.2 Attaching the inner rail to the serverp.523.3 Attaching the rails to the rackp.533.4 Mounting the server to the rackp.54Chapter 4: Motherboard Infop.554.1 Motherboard layoutp.564.2 Jumpersp.584.3 Internal connectorsp.63Chapter 5: BIOS setupp.735.1 Managing and updating your BIOSp.745.1.1 Creating a bootable floppy diskp.745.1.2 AFUDOS utilityp.755.1.3 ASUS CrashFree BIOS 3 utilityp.785.2 BIOS setup programp.795.2.1 BIOS menu screenp.805.2.2 Menu barp.805.2.3 Navigation keysp.805.2.4 Menu itemsp.815.2.5 Sub-menu itemsp.815.2.6 Configuration fieldsp.815.2.7 Pop-up windowp.815.2.8 Scroll barp.815.2.9 General helpp.815.3 Main menup.825.3.1 System Time [xx:xx:xx]p.825.3.2 System Date [Day xx/xx/xxxx]p.825.3.3 Legacy Diskette A [Disabled]p.825.3.4 SATA1–6; PATA Master/Slavep.835.3.5 IDE Configurationp.855.3.6 System Informationp.865.4 Advanced menup.875.4.1 USB Configurationp.875.4.2 CPU Configurationp.895.4.3 Chipsetp.915.4.4 Onboard Device Configurationp.935.4.5 PCIPnPp.945.5 Server menup.955.5.1 ASF Support [Enabled]p.955.5.2 Remote Access Configurationp.955.6 Power menup.975.6.1 ACPI 2.0 Support [Disabled]p.975.6.2 ACPI APIC Support [Enabled]p.975.7 Boot menup.1005.7.1 Boot Device Priorityp.1005.7.2 Boot Settings Configurationp.1015.7.3 Securityp.1025.8 Exit menup.104Chapter 6: RAID configurationp.1056.1 Setting up RAIDp.1066.1.1 RAID definitionsp.1066.1.2 Installing hard disk drivesp.1076.1.3 Setting the RAID item in BIOSp.1076.1.4 RAID configuration utilitiesp.1076.2 LSI Software RAID Configuration Utilityp.1086.2.1 Creating a RAID 0 or RAID 1 setp.1096.2.2 Creating a RAID 10 setp.1156.2.3 Adding or viewing a RAID configurationp.1196.2.4 Initializing the logical drivesp.1226.2.5 Rebuilding failed drivesp.1276.2.6 Checking the drives for data consistencyp.1296.2.7 Deleting a RAID configurationp.1326.2.8 Selecting the boot drive from a RAID setp.1336.2.9 Enabling the WriteCachep.1346.3 Intel® Matrix Storage Manager Option ROM Utilityp.1356.3.1 Creating a RAID 0 set (Stripe)p.1366.3.2 Creating a RAID 1 set (Mirror)p.1386.3.3 Creating a RAID 10 set (Stripe + Mirror)p.1396.3.4 Creating a RAID 5 set (Parity)p.1406.3.5 Deleting a RAID setp.1416.3.6 Resetting disks to Non-RAIDp.1426.3.7 Exiting the Intel® Matrix Storage Managerp.142Chapter 7: Driver installationp.1437.1 RAID driver installationp.1447.1.1 Creating a RAID driver diskp.1447.1.2 Installing the RAID controller driverp.1477.2 Intel® chipset device installationp.1557.3 LAN driver installationp.1587.4 VGA driver installationp.1617.4.1 Windows® Serverp.1617.5 Management applications and utilities installationp.1637.5.1 Running the support CDp.1637.5.2 Drivers menup.1637.5.3 Management Software menup.1647.5.4 Utilities menup.1647.5.5 Contact informationp.164
Page 7 of the Asus TS500-E5 user manual — Canadian Department of Communications Statement
Page 7 · click to enlarge
Page 7

Notices

Federal Communications Commission Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • This device may not cause harmful interference, and
  • This device must accept any interference received including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with manufacturer’ s instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Canadian Department of Communications Statement

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

This Class A digital apparatus complies with Canadian ICES-003.

This symbol of the crossed out wheeled bin indicates that the product (electrical, electronic equipment and mercury-containing button cell battery) should not be placed in municipal waste. Check local regulations for disposal of electronic products.

Page 8 of the Asus TS500-E5 user manual — CD-ROM Drive Safety Warning
Page 8 · click to enlarge
Page 8

Safety information

Electrical Safety

  • Before installing or removing signal cables, ensure that the power cables for the system unit and all attached devices are unplugged.
  • To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system.
  • When adding or removing any additional devices to or from the system, contact a qualified service technician or your dealer. Ensure that the power cables for the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you service.
  • If the power supply is broken, do not try to fix it by yourself. Contact a qualified service technician or your dealer.

Operation Safety

  • Servicing of this product or units is to be performed by trained service personnel only.
  • Before operating the server, carefully read all the manuals included with the server package.
  • Before using the server, make sure all cables are correctly connected and the power cables are not damaged. If any damage is detected, contact your dealer as soon as possible.
  • To avoid short circuits, keep paper clips, screws, and staples away from connectors, slots, sockets and circuitry.
  • Avoid dust, humidity, and temperature extremes. Place the server on a stable surface.

This product is equipped with a three-wire power cable and plug for the user’s safety. Use the power cable with a properly grounded electrical outlet to avoid electrical shock.

Lithium-Ion Battery Warning CAUTION! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

CD-ROM Drive Safety Warning

CLASS 1 LASER PRODUCT

Heavy System CAUTION! This server system is heavy. Ask for assistance when moving or carrying the system.

Page 9 of the Asus TS500-E5 user manual — 7 Chapter 7: Driver installation
Page 9 · click to enlarge
Page 9

About this guide

Audience

This user guide is intended for system integrators, and experienced users with at least basic knowledge of configuring a server.

Contents

This guide contains the following parts:

1. Chapter 1: Product Introduction

This chapter describes the general features of the server, including sections on front panel and rear panel specifications.

2. Chapter 2: Hardware setup

This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.

3. Chapter 3: Installation options

This chapter describes how to install optional components into the barebone server.

4. Chapter 4: Motherboard information

This chapter gives information about the motherboard that comes with the server. This chapter includes the motherboard layout, jumper settings, and connector locations.

5. Chapter 5: BIOS information

This chapter tells how to change system settings through the BIOS Setup menus and describes the BIOS parameters.

6. Chapter 6: RAID configuration

This chapter tells how to change system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.

7 Chapter 7: Driver installation

This chapter provides instructions for installing the necessary drivers for different system components.

Page 10 of the Asus TS500-E5 user manual — 2. ASUS websites
Page 10 · click to enlarge
Page 10

Conventions

To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual.

Typography

Bold text Indicates a menu or an item to select.

Italics Used to emphasize a word or a phrase.

Keys enclosed in the less-than and greater- than sign means that you must press the enclosed key.

Example: means that you must press the Enter or Return key.

If you must press two or more keys simultaneously, the key names are linked with a plus sign (+).

Example<Ctrl+Alt+D>

Command Means that you must type the command exactly as shown, then supply the required item or value enclosed in brackets.

ExampleAt the DOS prompt, type the command line: format A:/S

References

Refer to the following sources for additional information, and for product and software updates.

1. ASUS Server Web-based Management (ASWM) user guide

This manual tells how to set up and use the proprietary ASUS server management utility.

2. ASUS websites

The ASUS websites worldwide provide updated information for all ASUS hardware and software products. Refer to the ASUS contact information.

Page 11 of the Asus TS500-E5 user manual — Chapter 1
Page 11 · click to enlarge
Page 11

Chapter 1

Product introduction

This chapter describes the general features of the chassis kit. It includes sections on front panel and rear panel specifications.

Asus TS500-E5 — Chapter 1 diagram (page 11)
Fig. 2 · Chapter 1
Page 12 of the Asus TS500-E5 user manual — xxxxxxxxxxxx
Page 12 · click to enlarge
Page 12

1.1 System package contents

Check your system package for the following items.

Model Name TS500-E5/PA4 TS500-E5/RX8

Chassis ASUS T55 Pedestal 5U Rackmount Chassis

ASUS T55 Pedestal 5U Rackmount Chassis

Motherboard ASUS DSAN-DX/TS500-E5 Server Board

ASUS DSAN-DX/TS500-E5 Server Board

Component 1 x 670W Single Power Supply 1 x SATA/SAS Backplane (BP4LX-T55) with 4 x SATA Cables 4 x Hot-swap HDD trays 1 x Floppy Disk Drive 1 x Front I/O Board 1 x System RearFan (120mm x 38mm)

1 x 650W Redundant Power Supply 1 x SATA/SAS Backplane (BP4LX-T55) with 4 x SATA Cables 4 x Hot-swap HDD trays 1 x Floppy Disk Drive 1 x Front I/O Board 1 x System RearFan (120mm x 38mm)

Accessories 2 x CPU Coolers 1 x ASUS TS500-E5 User’s Guide 1 x ASUS ASWM 2.0 User’s Guide 1 x TS500-E5 Support CD (including ASWM*) 1 x Bag of Screws 1 x AC Power Cable

2 x CPU Coolers 1 x ASUS TS500-E5 User’s Guide 1 x ASUS ASWM 2.0 User’s Guide 1 x TS500-E5 Support CD (including ASWM*) 1 x Bag of Screws 1 x AC Power Cable

Optional Items CA eTrust Anti-virus Software CD ASUS TS500-E5 Rackmount Rail Kit 4-bay HDD Cage ASUS PIKE RAID Card

CA eTrust Anti-virus Software CD ASUS TS500-E5 Rackmount Rail Kit 650W Redundant Power Supply Module 4-bay HDD Cage ASUS PIKE RAID Card

*ASUS System Web-based Management

If any of the above items is damaged or missing, contact your retailer.

1.2 Serial number label

Before requesting support from the ASUS Technical Support team, you must take note of the product’s serial number containing 12 characters such as xxxxxxxxxxxx. See the figure below.

With the correct serial number of the product, ASUS Technical Support team members can then offer a quicker and satisfying solution to your problems.

TS500-E5

Asus TS500-E5 — TS500-E5 diagram (page 12)
Fig. 3

xxxxxxxxxxxx

Chapter 1Product introduction 1-2
Page 13 of the Asus TS500-E5 user manual — 1.3 System specifications
Page 13 · click to enlarge
Page 13

1.3 System specifications

The ASUS TS500-E5 is a 5U barebone server system featuring the ASUS DSAN-DX/TS500-E5 server board. The server supports Intel

® 5100 / 5200 / 5300 / 5400 series processors with EM64T technology, plus other latest technologies through the chipsets onboard.

Model Name TS500-E5/PA4 TS500-E5/RX8 Processor / System Bus 2 x Socket LGA771 Quad-Core Intel

® 5400 series Dual-Core Intel

® 5200 series Quad-Core Intel

® 5300 series Dual-Core Intel

® 5100 series FSB 1066/1333 MHz EM64T Core Logic Intel

® 5100 Memory Controller Hub (MCH) Intel

® ICH9R ASUS Features Smart Fan √ ASWM2.0 √ Memory Total Slots 6 (Dual-Channel) Capacity Maximum up to 24GB Memory Type DDR2 667 Registered ECC Memory Size 512 MB, 1 GB, 2GB and 4GB Expansion Slots Total PCI/PCI-X/

Slot Type Workstation Mode: 1 x PCI-E x16 slot (x16 link) 1 x PCI-E x8 slot (x8 link) 1 x PCI-E x8 slot (x4 link) or PIKE 1 x PCI 32-bit/33MHz slot

Server Mode: 1 x PCI-E x16 slot (x8 link) 2 x PCI-E x8 slot (x8 link) 1 x PCI-E x8 slot (x4 link) or PIKE 1 x PCI 32-bit/33MHz slot Additional Slot 1 1 x SO-DIMM socket Additional Slot 2 1 x Proprietary slot for optional ASUS PIKE Storage SATA Controller Intel

® ICH9R: 6 x SATA2 300MB/s ports Intel Matrix Storage (for Windows only) (Support software RAID 0, 1, 5 & 10)

LSI MegaRAID (for Linux/Windows) (Support software RAID 0, 1 & 10) SAS Controller Optional: ASUS PIKE 1064E 4 port SAS card - Supports RAID 0, 1 and 1E ASUS PIKE 1078 8 port SAS card - Supports RAID 0, 1, 5, 10, 50, 6 and 60

(continued on the next page)

Show 6 more labels / short text on this page
® LGA771 Xeon · ® Xeon · ® Xeon · ® Xeon · ® Xeon · PCI-E Slots
Page 14 of the Asus TS500-E5 user manual — 1.3 System specifications
Page 14 · click to enlarge
Page 14

Model Name TS500-E5/PA4 TS500-E5/RX8 HDD Bays I = internal A or S will be hot-swappable

Default4 x Hot-swap HDD Bays

Configuration Option: 4-bay HDD Cage + 4 x Hot-swap HDD Trays Networking LAN 2 x Broadcom ® BCM5721 PCI-E GbE LAN Graphic VGA XGI Z9S VGA Controller / 32MB DDRII SDRAM Auxiliary Storage FDD / CD / DVD 1 x FDD 2 x 5.25" media bays (Options: No ODD/DVD-ROM/DVD-RW) Onboard I/O 1 x External Serial Port 2 x RJ-45 ports 4 x USB 2.0 ports (Front x 2, Rear x 2) 1 x VGA port 1 x PS/2 keyboard port 1 x PS/2 mouse port

® Server 2003 R2 Enterprise 32/64-bit RedHat

® Enterprise Linux AS5 UP1 32/64-bit SuSE

® Linux Enterprise Server 10 SP1 32/64-bit (Subject to change without any notice) Anti-virus Software CA

® eTrust™ 7.1 anti-virus software (Optional) Management Solution ASUS ASWM 2.0 and SNMP Dimension (HH x WW x DD) 450mm x 212mm x 550mm Net Weight Kg (CPU, DRAM & HDD not included)

Power Supply 670W Single Power Supply

650W 1+1 Redundant Power Supply Environment Operation temperature: 10°C ~ 35°C Non operation temperature: -40°C ~ 70°C Non operation humidity: 20% ~ 90% ( Non condensing)

*Specifications are subject to change without notice.

Chapter 1Product introduction 1-4

Windows · OS Support · 20Kg

Page 15 of the Asus TS500-E5 user manual — LAN1 LED LAN2 LED
Page 15 · click to enlarge
Page 15

1.4 Front panel features

The barebone server displays a simple yet stylish front panel with easily accessible features. The power and reset buttons, LED indicators, optical drive, and two USB ports are located on the front panel.

The drive bays, power and reset buttons, LED indicators, CD/DVD-ROM drive, floppy drive, and USB 2.0 ports are located on the front panel. For future installation of 5.25-inch devices, two drive bays are available.

1.4.1 Four Hot-Swap HDD Devices

LAN1 LED LAN2 LED

Asus TS500-E5 — LAN1 LED LAN2 LED diagram (page 15)
Fig. 4

Empty 5.25-inch

USB 2.0 ports

Refer to section 1.7.1 Front panel LEDs for the LED descriptions.

Show 9 more labels / short text on this page
Message LED · HDD access LED · Power LED · Optical drive · bays · Security lock · Power button · Reset button · 4-bay HDD cage
Page 16 of the Asus TS500-E5 user manual — 1.4.2 Eight Hot-Swap HDD Devices
Page 16 · click to enlarge
Page 16

1.4.2 Eight Hot-Swap HDD Devices

Asus TS500-E5 — 1.4.2 Eight Hot-Swap HDD Devices diagram (page 16)
Fig. 5 · 1.4.2 Eight Hot-Swap HDD Devices

This server system provides 4-bay HDD Cage + 4 x Hot-swap HDD Trays as optional items.

Chapter 1Product introduction 1-6

4-bay HDD cage · 4-bay HDD cage

Page 17 of the Asus TS500-E5 user manual — 1.5.2 Redundant Power Supply (RX8 model)
Page 17 · click to enlarge
Page 17

1.5 Rear panel features

The rear panel includes a slot for the motherboard rear I/O ports, expansion slots, a chassis lock and intrusion switch, a vent for the system fan, and power supply module.

1.5.1 Single power supply (PA4 model)

Asus TS500-E5 — 1.5.1 Single power supply (PA4 model) diagram (page 17)
Fig. 6 · 1.5.1 Single power supply (PA4 model)

670W Single power supply

USB 2.0 ports

120mm x 38mm system fan

Gigabit LAN port 1

Gigabit LAN port 2

1.5.2 Redundant Power Supply (RX8 model)

Asus TS500-E5 — 1.5.2 Redundant Power Supply (RX8 model) diagram (page 17)
Fig. 7 · 1.5.2 Redundant Power Supply (RX8 model)

650W Redundant power supply

The second redundant power supply is an optional item.

Show 9 more labels / short text on this page
Chassis lock · Power connector · Chassis intrusion switch · PS/2 mouse port · PS/2 keyboard port · Serial port · VGA port · Expansion slots · Power connector
Page 18 of the Asus TS500-E5 user manual — 1.6 Internal features
Page 18 · click to enlarge
Page 18

1.6 Internal features

The barebone server includes the basic components as shown.

Asus TS500-E5 — 1.6 Internal features diagram (page 18)
Fig. 8 · 1.6 Internal features
1. Power supply unit:
5. Expansion card locks
PA4 model670W Single Power Supply
6. Optical drive
7. 2 x 5.25-inch drive bays
RX8 model650W Redundant Power Supply (the second set is an optional item)
8. 4-bay HDD module (first set)
9. 4-bay HDD module (second set, optional)
2. 120mm x 38mm system fan
10. SATA/SAS backplane board (first set, hidden)
3. ASUS DSAN-DX/TS500-E5 Server Board
11. SATA/SAS backplane board (second set, hidden)
4. Chassis intrusion switch
Chapter 1Product introduction 1-8
Page 19 of the Asus TS500-E5 user manual — ON
Page 19 · click to enlarge
Page 19

1.7 LED information

1.7.1 Front panel LEDs

LAN1 LED LAN2 LED HDD Access LED

LED Icon Display status Description Power LED ON System power ON

HDD Access LED OFF Blinking

No activity Read/write data into the HDD

Message LED OFF Blinking

System is normal; no incoming event ASWM indicates a HW monitor event

Bridge board connected to backplane Installed HDD is in good condition

HDD rebuilding using the RAID card

Read/write data into the HDD

ON

The Power, HDD Access, LAN and Message LEDs are visible even if the system front bezel is closed.

Show 10 more labels / short text on this page
Message LED · Power LED · Drive Status LED · Green · Drive status LED · HDD failure · Red · Green/Red blinking · OFF Blinking · LAN LEDs
Page 20 of the Asus TS500-E5 user manual — ACT/LINK LED
Page 20 · click to enlarge
Page 20

1.7.2 Rear panel LEDs

Asus TS500-E5 — 1.7.2 Rear panel LEDs diagram (page 20)
Fig. 9 · 1.7.2 Rear panel LEDs

ACT/LINK LED

SPEED LED

ACT/LINK LED

SPEED LED

ACT/LINK LED SPEED LED Status Description Status Description OFF No link OFF 10 Mbps connection GREEN Linked ORANGE 100 Mbps connection BLINKING Data activity GREEN 1 Gbps connection

Chapter 1Product introduction 1-10
Page 21 of the Asus TS500-E5 user manual — Chapter 2
Page 21 · click to enlarge
Page 21

Chapter 2

Hardware setup

This chapter lists the hardware setup procedures that you have to perform when installing or removing system components.

Asus TS500-E5 — Chapter 2 diagram (page 21)
Fig. 10 · Chapter 2
Page 22 of the Asus TS500-E5 user manual — 2.1.1 Removing the side cover
Page 22 · click to enlarge
Page 22

2.1 Chassis cover

2.1.1 Removing the side cover

  • Ensure that you unplug the power cord before removing the side cover.
  • Take extra care when removing the side cover. Keep your fingers from components inside the chassis that can cause injury, such as the CPU fan, rear fan, and other sharp-edged parts.

To reinstall the side cover:

1. Remove the two screws that secure the side cover.
Asus TS500-E5 — 2.1.1 Removing the side cover diagram (page 22)
Fig. 11 · 2.1.1 Removing the side cover
2. Press the blue latch button and slide the side cover for about half an inch toward the rear until it is disengaged from the chasssis.
Asus TS500-E5 — 2.1.1 Removing the side cover diagram (page 22)
Fig. 12 · 2.1.1 Removing the side cover
3. Carefully lift the side cover and set it aside.
Chapter 2Hardware setup 2-2
Page 23 of the Asus TS500-E5 user manual — 2.1.2 Reinstalling the side cover
Page 23 · click to enlarge
Page 23

2.1.2 Reinstalling the side cover

To reinstall the side cover:

1. Match and insert the lower sliding edge of the side cover to the corresponding chassis edge.
Asus TS500-E5 — 2.1.2 Reinstalling the side cover diagram (page 23)
Fig. 13 · 2.1.2 Reinstalling the side cover
2. Position the side cover to the chassis.
3. Press the blue latch button and slide the side cover toward the front panel until it snaps in place.
4. Drive in the two screws you removed earlier to secure the side cover.
Page 24 of the Asus TS500-E5 user manual — DSAN-DX/TS500-E5 CPU LGA771
Page 24 · click to enlarge
Page 24

2.2 Central Processing Unit (CPU)

The motherboard comes with a surface mount LGA771 socket designed for the Intel® Xeon® Dual/Quad Core processor.

  • Your boxed Intel ® Xeon ® LGA771 processor package should come with installation instructions for the CPU and heatsink. If the instructions in this section do not match the CPU documentation, follow the latter.
  • Upon purchase of the motherboard, make sure that the PnP cap is on the socket and the socket contacts are not bent. Contact your retailer immediately if the PnP cap is missing, or if you see any damage to the PnP cap/socket contacts/motherboard components. ASUS will shoulder the cost of repair only if the damage is shipment/transit-related.
  • Keep the cap after installing the motherboard. ASUS will process Return Merchandise Authorization (RMA) requests only if the motherboard comes with the cap on the LGA771 socket.
  • The product warranty does not cover damage to the socket contacts resulting from incorrect CPU installation/removal, or misplacement/loss/ incorrect removal of the PnP cap.
  • If you install only one CPU, install the CPU to the CPU2 socket only. The system will not boot and the CPU warning LED will light up if a single CPU is installed on the CPU1 socket.

2.2.1 Installing the CPU

To install a CPU:

1. Locate the CPU socket on the motherboard.
Asus TS500-E5 — 2.2.1 Installing the CPU diagram (page 24)
Fig. 14 · 2.2.1 Installing the CPU
Asus TS500-E5 — 2.2.1 Installing the CPU diagram (page 24)
Fig. 15 · 2.2.1 Installing the CPU

DSAN-DX/TS500-E5 CPU LGA771

Before installing the CPU, make sure that the socket box is facing towards you and the load lever is on your left.

Chapter 2Hardware setup 2-4
Page 25 of the Asus TS500-E5 user manual — B
Page 25 · click to enlarge
Page 25
2. Press the load lever with your thumb (A), then move it to the left (B) until it is released from the retention tab.
Asus TS500-E5 — 2.2 Central Processing Unit (CPU) diagram (page 25)
Fig. 16 · 2.2 Central Processing Unit (CPU)

A

B

This side of the socket box should face you.

To prevent damage to the socket pins, do not remove the PnP cap unless you are installing a CPU.

3. Lift the load lever in the direction of the arrow to a 135º angle.
Asus TS500-E5 — A diagram (page 25)
Fig. 17
4. Lift the load plate with your thumb and forefinger to a 100º angle (A), then push the PnP cap from the load plate window to remove (B).
Asus TS500-E5 — A diagram (page 25)
Fig. 18

B

A

Asus TS500-E5 — B diagram (page 25)
Fig. 19
5. Position the CPU over the socket, making sure that the gold triangle is on the bottom-left corner of the socket. The socket alignment key should fit into the CPU notch.
Show 6 more labels / short text on this page
Retention tab · Load lever · PnP cap · Load plate · Alignment key · Gold triangle mark
Page 26 of the Asus TS500-E5 user manual — B
Page 26 · click to enlarge
Page 26

The CPU fits in only one correct orientation. DO NOT force the CPU into the socket to prevent bending the connectors on the socket and damaging the CPU!

A

6. Close the load plate (A), then push the load lever (B) until it snaps into the retention tab.
Asus TS500-E5 — A diagram (page 26)
Fig. 20

B

Chapter 2Hardware setup 2-6
Page 27 of the Asus TS500-E5 user manual — 2.2.2 Installing the CPU heatsink and fan
Page 27 · click to enlarge
Page 27

2.2.2 Installing the CPU heatsink and fan

To install the CPU heatsink and fan:

1. Place the CPU heatsink and fan on top of the installed CPU, making sure that the four screws match the holes on the support plate.
Asus TS500-E5 — 2.2.2 Installing the CPU heatsink and fan diagram (page 27)
Fig. 21 · 2.2.2 Installing the CPU heatsink and fan
2. Twist each of the four screws with a Philips (cross) screwdriver just enough to attach the CPU heatsink and fan to the motherboard. When the four screws are attached, tighten them one by one to completely secure the CPU heatsink and fan.
Asus TS500-E5 — 2.2.2 Installing the CPU heatsink and fan diagram (page 27)
Fig. 22 · 2.2.2 Installing the CPU heatsink and fan
3. Connect the CPU heatsink and fan cable to the connector on the motherboard.
Asus TS500-E5 — 2.2.2 Installing the CPU heatsink and fan diagram (page 27)
Fig. 23 · 2.2.2 Installing the CPU heatsink and fan

Do not forget to connect the CPU heatsink and fan connector! Hardware monitoring errors can occur if you fail to plug this connector.

Asus TS500-E5 — 2.2.2 Installing the CPU heatsink and fan diagram (page 27)
Fig. 24 · 2.2.2 Installing the CPU heatsink and fan
Page 28 of the Asus TS500-E5 user manual — 2.3.2 Memory configurations
Page 28 · click to enlarge
Page 28

2.3 System memory

2.3.1 Overview

The motherboard comes with six (6) Double Data Rate 2 (DDR2) Dual Inline Memory Modules (DIMM) sockets.

A DDR2 module has the same physical dimensions as a DDR DIMM but has a 240-pin footprint compared to the 184-pin DDR DIMM.

The figure illustrates the location of the DDR2 DIMM sockets:`

Asus TS500-E5 — 2.3.1 Overview diagram (page 28)
Fig. 25 · 2.3.1 Overview

2.3.2 Memory configurations

You may install 512 MB, 1 GB, 2 GB, and 4 GB registered ECC DIMMs into the DIMM sockets.

  • For optimum compatibility, we recommend that you obtain memory modules from the same vendor. Refer to the Qualified Vendors List on the ASUS web site.
  • This motherboard does not support memory modules made up of 128 Mb chips x16 memory modules.
  • If you are installing only one memory module, install the module into the blue socket labeled DIMM_A1 or DIMM_B1. Installing into any other socket will not work.
Chapter 2Hardware setup 2-8
Page 29 of the Asus TS500-E5 user manual — 2 DIMM_B1, DIMM_A1
Page 29 · click to enlarge
Page 29

Rank population

DIMM_A3

DIMM_B3

DIMM_A2

DIMM_B2

DIMM_A1

DIMM_B1

MCH

DIMM installation reference table

No. of DIMMs

1 DIMM_B1 or DIMM_A1

2 DIMM_B1, DIMM_A1

4 DIMM_B1, DIMM_A1, DIMM_B2, DIMM_A2

6 DIMM_B1, DIMM_A1, DIMM_B2, DIMM_A2 DIMM_B3, DIMM_A3

  • DIMMs in pair means two DIMMs with the same configuration.
  • For better performance, same configuration DIMMs should be installed on the same slot number for each channel. For example, you may install the same type of DIMMs in DIMM_B1, and DIMM_A1.

Slot/s to use

Page 30 of the Asus TS500-E5 user manual — Memory Sparing
Page 30 · click to enlarge
Page 30

2.3.3 Memory mirroring and sparing technology

The Intel® 5100MCH chipset supports the memory sparing technology. Refer to the below section:

Memory Sparing

At configuration time, a DIMM rank is set aside to replace a defective DIMM rank. When the error rate for a failing DIMM rank reaches a pre-determined threshold, the memory sparing function will issue an interrupt and initiate a spare copy. At the completion of the copy, the failing DIMM rank is disabled and the “spared” DIMM rank will be used in its place. Refer to section 5.4.3 Chipset and configure the options of Channel Rank Sparing or Channel 1 Rank Sparing to enable the memory sparing functions. The default BIOS setting is disabled.

  • Each channel contains its own sparing engine and can be enabled or disabled separately.
  • This motherboard does not support rank sparing across channels.
  • The DIMM rank with the largest size will be assigned as spare rank. Data can only be copied from a smaller sized rank to a larger sized one.
  • A DIMM can contain only one or two ranks. To support sparing function, a DIMM channel should contain at least two ranks.
  • When sparing function is enabled, the usable memory size will reduce the size of the spare ranks.

The following tables show memory configurations with Memory Sparing function in Channel A/B.

One DIMM per channel (two ranks)

Channel B Channel A

Rank 0 (1024 MB)

Rank 1 (1024 MB)

Rank 0 (1024 MB)

Rank 1 (1024 MB)

Memory space 1024 MB 1024 MB

Total Memory 2048 MB

Chapter 2Hardware setup 2-10

DIMM_B1 (1024MB*2 Ranks) · DIMM_A1 (1024MB*2 Ranks) · Sparing

Page 31 of the Asus TS500-E5 user manual — 2.3.3 Memory mirroring and sparing technology
Page 31 · click to enlarge
Page 31

Two DIMMs per channel

Asus TS500-E5 — 2.3.3 Memory mirroring and sparing technology diagram (page 31)
Fig. 26 · 2.3.3 Memory mirroring and sparing technology

Three DIMMs per channel

Asus TS500-E5 — 2.3.3 Memory mirroring and sparing technology diagram (page 31)
Fig. 27 · 2.3.3 Memory mirroring and sparing technology
Page 32 of the Asus TS500-E5 user manual — 2.3.5 Removing a DIMM
Page 32 · click to enlarge
Page 32

2.3.4 Installing a DIMM

Make sure to unplug the power supply before adding or removing DIMMs or other system components. Failure to do so may cause severe damage to both the motherboard and the components.

To install a DIMM:

1. Unlock a DIMM socket by pressing the retaining clips outward.
Asus TS500-E5 — 2.3.4 Installing a DIMM diagram (page 32)
Fig. 28 · 2.3.4 Installing a DIMM
2. Align a DIMM on the socket such that the notch on the DIMM matches the break on the socket.
3. Firmly insert the DIMM into the socket until the retaining clips snap back in place and the DIMM is properly seated.
  • A DDR2 DIMM is keyed with a notch so that it fits in only one direction. Do not force a DIMM into a socket to avoid damaging the DIMM.
  • The DDR2 DIMM sockets do not support DDR DIMMs. Do not install DDR DIMMs to the DDR2 DIMM sockets.

2.3.5 Removing a DIMM

To remove a DIMM:

1. Simultaneously press the retaining clips outward to unlock the DIMM.

Support the DIMM lightly with your fingers when pressing the retaining clips. The DIMM might get damaged when it flips out with extra force.

DDR2 DIMM notch 1

2. Remove the DIMM from the socket.
Chapter 2Hardware setup 2-12

DDR2 DIMM notch · Unlocked retaining clip

Page 33 of the Asus TS500-E5 user manual — 2.4.2 Reinstalling the front panel assembly
Page 33 · click to enlarge
Page 33

2.4 Front panel assembly

Before you can install a 5.25-inch drive, you should first remove the front panel assembly (front bezel and front panel cover).

2.4.1 Removing the front panel assembly

To remove the front panel assembly:

1. Unlock the front door if needed.
Asus TS500-E5 — 2.4.1 Removing the front panel assembly diagram (page 33)
Fig. 29 · 2.4.1 Removing the front panel assembly
2. Locate the two hooked tabs on the chassis side rail.
3. Shift the hooked tabs and take off the front bezel.

2.4.2 Reinstalling the front panel assembly

To reinstall the front panel assembly:

1. Hook the other side of the front panel assembly to the chassis.
Asus TS500-E5 — 2.4.2 Reinstalling the front panel assembly diagram (page 33)
Fig. 30 · 2.4.2 Reinstalling the front panel assembly
2. Swing the front panel assembly and snap it back into place.
Page 34 of the Asus TS500-E5 user manual — 2.5.1 Installing a 5.25-inch drive
Page 34 · click to enlarge
Page 34

2.5 5.25-inch or 3.5-inch drives

Ensure to unplug the power cable before installing or removing any system components. Failure to do so may cause damage to the motherboard and other system components!

The system comes with three 5.25-inch drive bays located on the upper front part of the chassis. You can use the bay converter that comes with the package to convert the 5.25-inch bay to 3.5-inch bay for 3.5-inch device such as floppy disk drives.

Asus TS500-E5 — 2.5 5.25-inch or 3.5-inch drives diagram (page 34)
Fig. 31 · 2.5 5.25-inch or 3.5-inch drives

You must remove the front panel assembly before installing a 5.25-inch drive.

2.5.1 Installing a 5.25-inch drive

1. Unscrew and remove the metal cover of the bay where you want to install the 5.25-inch drive, and take off the plastic cover on the front bezel at the same position.
Asus TS500-E5 — 2.5.1 Installing a 5.25-inch drive diagram (page 34)
Fig. 32 · 2.5.1 Installing a 5.25-inch drive
2. Insert the drive into the bay and slide the bay lock to the right until it clicks in place. Screw to double secure the drive.
3. Connect the IDE cable to the IDE connector on the back of the drive.
Asus TS500-E5 — 2.5.1 Installing a 5.25-inch drive diagram (page 34)
Fig. 33 · 2.5.1 Installing a 5.25-inch drive
4. Connect a 4-pin plug from the power supply to the power connector on the back of the drive.
Chapter 2Hardware setup 2-14

screw hole · IDE cable · Power plug

Page 35 of the Asus TS500-E5 user manual — 2.5.2 Installing a 3.5-inch drive
Page 35 · click to enlarge
Page 35

2.5.2 Installing a 3.5-inch drive

1. Remove the metal bracket in front of the drive bay converter.
2. Install the 3.5-inch disk drive into the converter.
3. Screw the 3.5-inch disk drive on the bay converter.
Asus TS500-E5 — 2.5.2 Installing a 3.5-inch drive diagram (page 35)
Fig. 34 · 2.5.2 Installing a 3.5-inch drive
Asus TS500-E5 — 2.5.2 Installing a 3.5-inch drive diagram (page 35)
Fig. 35 · 2.5.2 Installing a 3.5-inch drive

3.5" Floppy disk drive 3.5" Hard disk drive

4. Insert the converter installed with 3.5-inch disk drive into the chassis and secure it as the 5.25-inch drives.
Page 36 of the Asus TS500-E5 user manual — b a
Page 36 · click to enlarge
Page 36

2.6 SATA/SAS hard disk drives

The optional two hard disk drive modules on the front panel, including externally removable trays for mounting either SATA or SAS hard disk drives, allow you to access the drive trays by simply opening the the front bezel.

A hot-swap HDD module cage comes with a SATA or SATS backplane. Make sure of the type of HDD module cage you purchase before buying hard disks.

2.6.1 Hot-swap HDD module

To install the hot-swap HDD module:

1. Examine the chassis and make sure the bay space is free of wires and other obstructions.
2. Insert the hot-swap HDD module into the bay.
Asus TS500-E5 — To install the hot-swap HDD module: diagram (page 36)
Fig. 36 · To install the hot-swap HDD module:
3. To remove the hot-swap HDD module, lift up the blue latch (a), then pull out the hot-swap HDD module (b).
Asus TS500-E5 — To install the hot-swap HDD module: diagram (page 36)
Fig. 37 · To install the hot-swap HDD module:

b a

Chapter 2Hardware setup 2-16
Page 37 of the Asus TS500-E5 user manual — To install a SATA/SAS hard disk drive:
Page 37 · click to enlarge
Page 37

To install a SATA/SAS hard disk drive:

1. Pull down the tray lever until the tray pops out slightly, indicating that it is released.
Asus TS500-E5 — To install a SATA/SAS hard disk drive: diagram (page 37)
Fig. 38 · To install a SATA/SAS hard disk drive:
2. Holding on the tray lever, pull out the HDD tray from the bay.
Asus TS500-E5 — To install a SATA/SAS hard disk drive: diagram (page 37)
Fig. 39 · To install a SATA/SAS hard disk drive:
3. Unscrew and remove the blank tray from the frame.
Asus TS500-E5 — To install a SATA/SAS hard disk drive: diagram (page 37)
Fig. 40 · To install a SATA/SAS hard disk drive:
4. Place a hard disk drive on the tray and secure it with four screws.
Asus TS500-E5 — To install a SATA/SAS hard disk drive: diagram (page 37)
Fig. 41 · To install a SATA/SAS hard disk drive:
Page 38 of the Asus TS500-E5 user manual — 2.6 SATA/SAS hard disk drives
Page 38 · click to enlarge
Page 38
5. Insert the HDD-installed tray back into the bay.
6. Carefully push the tray all the way to the depth of the bay.
7. Push the tray lever until it clicks in place. The drive tray is correctly placed when its front edge aligns with the bay edge.
Chapter 2Hardware setup 2-18
Page 39 of the Asus TS500-E5 user manual — Removing and reinstalling the backplane
Page 39 · click to enlarge
Page 39

Removing and reinstalling the backplane

DO NOT remove the backplane unless necessary!

1. Remove the hot-swap HDD module from the bay if it has been installed.
2. Pull down the tray lever until the tray pops out slightly, indicating that it is released.
3. Repeat the previous step to release all the installed disk drives.
4. Loosen both screws with a screw driver or your fingers.
Asus TS500-E5 — Removing and reinstalling the backplane diagram (page 39)
Fig. 42 · Removing and reinstalling the backplane
5. Push the backplane outward so that the outer edge protrudes slightly from the slot.
Asus TS500-E5 — Removing and reinstalling the backplane diagram (page 39)
Fig. 43 · Removing and reinstalling the backplane
6. Hold on to the backplane, lift it up and remove it from the module.
7. Follow the previous instructions in reverse to reinstall the backplane.
Page 40 of the Asus TS500-E5 user manual — 2.7.1 Installing an expansion card
Page 40 · click to enlarge
Page 40

2.7 Expansion cards

The system is designed with an expansion card lock on the rear panel for you to install or remove an expansion card in less steps.

Ensure to unplug the power cord before installing or removing expansion cards. Failure to do so may cause severe damage to the motheboard and other system components!

2.7.1 Installing an expansion card

1. Before installing the expansion card, read the documentation that came with it and make the necessary hardware settings for the card.
2. Lay the system on its side on a flat, stable surface.
3. Use a Phillips screw driver to remove the metal slot cover opposite the slot where you wish to install an expansion card.
Asus TS500-E5 — 2.7.1 Installing an expansion card diagram (page 40)
Fig. 44 · 2.7.1 Installing an expansion card
4. Lift the expansion card lock.
Asus TS500-E5 — 2.7.1 Installing an expansion card diagram (page 40)
Fig. 45 · 2.7.1 Installing an expansion card
5. Align the card golden fingers with the slot, and then press firmly until the card is completely seated on the slot.
Asus TS500-E5 — 2.7.1 Installing an expansion card diagram (page 40)
Fig. 46 · 2.7.1 Installing an expansion card
Chapter 2Hardware setup 2-20
Page 41 of the Asus TS500-E5 user manual — 2.7.2 Installing ASUS PIKE RAID card
Page 41 · click to enlarge
Page 41
6. Restore the expansion card lock to its original position. A light click indicates that the card is locked in place.
Asus TS500-E5 — 2.7.2 Installing ASUS PIKE RAID card diagram (page 41)
Fig. 47 · 2.7.2 Installing ASUS PIKE RAID card

When installing a graphics card on PCI-E x16 slot, the PCI-E slot right beside it does not function.

2.7.2 Installing ASUS PIKE RAID card

Follow the steps below to install an optional ASUS RAID card on your motherboard.

1. Locate the PIKE RAID card slot on the motherboard.
Asus TS500-E5 — 2.7.2 Installing ASUS PIKE RAID card diagram (page 41)
Fig. 48 · 2.7.2 Installing ASUS PIKE RAID card
2. Align the golden fingers of the RAID card with the PIKE RAID card slot.
Asus TS500-E5 — 2.7.2 Installing ASUS PIKE RAID card diagram (page 41)
Fig. 49 · 2.7.2 Installing ASUS PIKE RAID card
3. Insert the RAID card into the PIKE RAID card slot. Make sure it is completely seated on the PIKE RAID card slot.
Asus TS500-E5 — 2.7.2 Installing ASUS PIKE RAID card diagram (page 41)
Fig. 50 · 2.7.2 Installing ASUS PIKE RAID card

When installing a PIKE RAID card on the PIKE RAID card slot, the PCI-E slot right beside it does not function.

Page 42 of the Asus TS500-E5 user manual — Standard Interrupt assignments
Page 42 · click to enlarge
Page 42

2.7.3 Configuring an expansion card

After installing the expansion card, configure the it by adjusting the software settings.

1. Turn on the system and change the necessary BIOS settings, if any. See Chapter 5 for information on BIOS setup.
2. Assign an IRQ to the card. Refer to the following tables.
3. Install the software drivers for the expansion card.

Standard Interrupt assignments

Asus TS500-E5 — Standard Interrupt assignments diagram (page 42)
Fig. 51 · Standard Interrupt assignments

* These IRQs are usually available for ISA or PCI devices.

Chapter 2Hardware setup 2-22
Page 43 of the Asus TS500-E5 user manual — 7 10 9 Standard cables connected to the motherboard
Page 43 · click to enlarge
Page 43

2.8 Cable connections

  • The bundled system cables are pre-connected before shipment. You do not need to disconnect these cables unless you will remove pre‑installed components to install additional devices.
  • Refer to Chapter 4 for detailed information on the connectors.

2.8.1 Motherboard connections

24.5cm (9.6in)

Asus TS500-E5 — 2.8.1 Motherboard connections diagram (page 43)
Fig. 52 · 2.8.1 Motherboard connections

7 10 9 Standard cables connected to the motherboard

1. 24-pin ATX power connector (from power supply to motherboard)
2. 8-pin 12V power connector (from power supply to motherboard)
3. Power supply SMBus connector (from power supply to motherboard)
4. System fan connectors (from system fan to motherboard)
5. USB connector (from motherboard to front I/O board)
6. IDE connector (from motherboard to the optional drive)
7. Chassis Intrusion connector (from rear chassis intrusion switch to motherboard)
8. Serial General Purpose Input/Output connectors (SATA: from motherboard SGPIO1 to SATA/SAS backplane J2 connector SAS: from motherboard SGPIO2 to SATA/SAS backplane J6 connector SAS: from motherboard SGPIO3 to SATA/SAS backplane J7 connector)
9. System panel connector (from motherboard to front I/O board)
10. SAS connectors (for ASUS PIKE only; from motherboard to SATA/SAS backplane)
Page 44 of the Asus TS500-E5 user manual — HDD 1 CON0 CON4
Page 44 · click to enlarge
Page 44

2.8.2 SATA/SAS backplane connections

A SATA/SAS backplane comes pre-installed in the TS500-E5. The SATA/SAS backplane has four 22-pin SATA/SAS connectors to support Serial ATA hard disk drives and SAS hard disk drives. The backplane design incorporates a hot swap feature to allow easy connection or removal of SATA/SAS hard disks. The LEDs on the backplane connect to the front panel LEDs to indicate HDD status. See section “1.6 LED information” for details.

Front side

The front side of the SATA/SAS backplane faces the front panel when installed. This side includes four SATA/SAS connectors for the hot swap drive trays.

Asus TS500-E5 — Front side diagram (page 44)
Fig. 53 · Front side

CON0 CON1 CON2 CON3

Each SATA/SAS connector is labeled (CON0, CON1, CON2, CON3) so you can easily determine their counterpart connectors at the back side of the backplane. Refer to the table for reference.

Asus TS500-E5 — CON0 CON1 CON2 CON3 diagram (page 44)
Fig. 54

HDD Device Front side connector Back side connector

HDD 1 CON0 CON4

HDD 2 CON1 CON5

HDD 3 CON2 CON6

HDD 4 CON3 CON7

Chapter 2Hardware setup 2-24

Drive status LEDs

Page 45 of the Asus TS500-E5 user manual — CON4/CON5/
Page 45 · click to enlarge
Page 45

Back side

The back side of the SATA/SAS backplane faces the rear panel when installed. This side includes the power connectors and SATA/SAS interfaces for the motherboard Serial ATA connectors or the SAS card.

Asus TS500-E5 — Back side diagram (page 45)
Fig. 55 · Back side

J2 Connects to SATA SGPIO1 connector on the motherboard

J6 Connects to SAS SGPIO2 connector on the motherboard

J7 Connects to SAS SGPIO3 connector on the motherboard

J8 Links backplane1 and backplane2 signals

J10 Links to add-on card failed LED signal

U1 Connects to 4-pin plug of the power supply

CON4/CON5/

CON6/CON7 Connects to SATA/SAS connectors on the motherboard

Connectors Description

Page 46 of the Asus TS500-E5 user manual — 2.9.1 System fan
Page 46 · click to enlarge
Page 46

2.9 Removable components

You may need to remove previously installed system components when installing or removing system devices, or when you need to replace defective components. This section tells how to remove the following components:

1. System fan
2. Chassis footpads
3. Power supply unit

2.9.1 System fan

To remove the system fan:

1. Unplug the system fan cable from the REAR_FAN2 connector on the motherboard.
Asus TS500-E5 — 2.9.1 System fan diagram (page 46)
Fig. 56 · 2.9.1 System fan
2. Shift the two hooked tabs upward and downward.
Asus TS500-E5 — 2.9.1 System fan diagram (page 46)
Fig. 57 · 2.9.1 System fan
3. Carefully take off the system fan.
Asus TS500-E5 — 2.9.1 System fan diagram (page 46)
Fig. 58 · 2.9.1 System fan
Chapter 2Hardware setup 2-26
Page 47 of the Asus TS500-E5 user manual — 2.9 Removable components
Page 47 · click to enlarge
Page 47

To reinstall the system fan:

1. Shift the two hooked tabs upward and downward, and then install the system fan. A light click indicates that the system fan is secured in place.
2. Plug the system fan cable to the REAR_FAN2 connector on the motherboard.
Page 48 of the Asus TS500-E5 user manual — 2.9.2 Chassis footpads
Page 48 · click to enlarge
Page 48

2.9.2 Chassis footpads

The barebone server system is shipped with four footpads attached to the bottom of the chassis for stability. You need to remove these footpads if you wish to install the system to a rack (Refer to Chapter 3: Installation options of this user guide, and to the “Rackmount Kit” user guide for instructions)

To remove the footpads:

1. Lay the system chassis on its side.
Asus TS500-E5 — 2.9.2 Chassis footpads diagram (page 48)
Fig. 59 · 2.9.2 Chassis footpads
2. Use a flat screwdriver to flip out the top layer of a footpad.
3. Remove the footpad by rotating it counterclockwise.
Asus TS500-E5 — 2.9.2 Chassis footpads diagram (page 48)
Fig. 60 · 2.9.2 Chassis footpads
4. Repeat steps 2 and 3 to remove the other three footpads.
Chapter 2Hardware setup 2-28
Page 49 of the Asus TS500-E5 user manual — Installing the redundant power supply module
Page 49 · click to enlarge
Page 49

2.9.3 Power supply unit

The system is compatible with both EPS 12 V 670 W single power supply and 650 W redundant power supply. Purchase based on your needs.

You MUST disconnect all power cable plugs from the motherboard and other installed devices before removing the power supply unit.

Installing the single power supply unit

1. Align the single power supply unit (PSU) in the chassis with the four mounting screw holes.
Asus TS500-E5 — Installing the single power supply unit diagram (page 49)
Fig. 61 · Installing the single power supply unit
2. Make the PSU sit on the shelf ledge when fastening it to the chassis with screws.
3. Fasten the two screws on the chassis wall.
Asus TS500-E5 — Installing the single power supply unit diagram (page 49)
Fig. 62 · Installing the single power supply unit

Installing the redundant power supply module

1. Unscrew and remove the power supply brackets at the back and on the chassis wall.
2. Screw the metal bracket from the chassis wall to the redundant power supply cage.
Asus TS500-E5 — Installing the redundant power supply module diagram (page 49)
Fig. 63 · Installing the redundant power supply module
Page 50 of the Asus TS500-E5 user manual — 2.9.3 Power supply unit
Page 50 · click to enlarge
Page 50
3. Insert the redundant power supply into the power supply bay.
Asus TS500-E5 — 2.9.3 Power supply unit diagram (page 50)
Fig. 64 · 2.9.3 Power supply unit
4. Make the redundant power supply cage sit on the shelf ledge when fastening it to the chassis with screws.
Asus TS500-E5 — 2.9.3 Power supply unit diagram (page 50)
Fig. 65 · 2.9.3 Power supply unit
5. Fasten the two screws on the chassis wall.
Asus TS500-E5 — 2.9.3 Power supply unit diagram (page 50)
Fig. 66 · 2.9.3 Power supply unit
6. Slide the power supply module into the bay, and press until the release/ lock lever clicks to lock the module securely.
Asus TS500-E5 — 2.9.3 Power supply unit diagram (page 50)
Fig. 67 · 2.9.3 Power supply unit
7. Install the other redundant power supply module as the first one.
Asus TS500-E5 — 2.9.3 Power supply unit diagram (page 50)
Fig. 68 · 2.9.3 Power supply unit
Chapter 2Hardware setup 2-30
Page 51 of the Asus TS500-E5 user manual — Chapter 3
Page 51 · click to enlarge
Page 51

Chapter 3

Installation options

This chapter describes how to install the optional components and devices into the barebone server.

Page 52 of the Asus TS500-E5 user manual — 3.2 Attaching the inner rail to the server
Page 52 · click to enlarge
Page 52

3.1 Preparing the system for rack mounting

  • The items required for the optional configurations described in this chapter are not included in the standard barebone system package. These items are purchased separately.
  • We recommend that you allot at least 1U space above the server system to ensure optimal thermal performance.

Removing the footpads

Refer to section 2.9.2 Chassis footpads for instructions on removing the footpads.

Removing the top cover

Asus TS500-E5 — Removing the top cover diagram (page 52)
Fig. 69 · Removing the top cover

Unscrew and slide the top cover toward the rear panel, and then lift it up from the chassis.

3.2 Attaching the inner rail to the server

1. Slide out the inner rail from the rackmount rail kit.
2. Align the screw holes on the inner rail and the chassis top, and then secure the inner rail to the chassis top with screws.
Asus TS500-E5 — 3.2 Attaching the inner rail to the server diagram (page 52)
Fig. 70 · 3.2 Attaching the inner rail to the server
3. Repeat the previous steps to secure the other inner rail to the bottom of the chassis with screws.
Asus TS500-E5 — 3.2 Attaching the inner rail to the server diagram (page 52)
Fig. 71 · 3.2 Attaching the inner rail to the server
Chapter 3Installation options 3-2
Page 53 of the Asus TS500-E5 user manual — 3.3 Attaching the rails to the rack
Page 53 · click to enlarge
Page 53

3.3 Attaching the rails to the rack

To attach the rails to the rack:

1. Select one unit of space (1U) on the rack where you wish to install the server.
Asus TS500-E5 — 3.3 Attaching the rails to the rack diagram (page 53)
Fig. 72 · 3.3 Attaching the rails to the rack
2. Loosen the two screws on the rack rails.
Asus TS500-E5 — 3.3 Attaching the rails to the rack diagram (page 53)
Fig. 73 · 3.3 Attaching the rails to the rack
3. Align the front end holes of a rack rail pair to the 1U space.
Asus TS500-E5 — 3.3 Attaching the rails to the rack diagram (page 53)
Fig. 74 · 3.3 Attaching the rails to the rack
4. Drive in two screws on the outer holes to secure the front end.
5. Find the rear 1U space that corresponds to the front 1U space where you attached the rail.
6. Drive in two screws on the outer holes to secure the rear end.
7. From the rack front, find the corresponding 1U space for the second rail pair.
8. Repeat steps 3–6 to attach the second rail pair.

1U space

Page 54 of the Asus TS500-E5 user manual — 3.4 Mounting the server to the rack
Page 54 · click to enlarge
Page 54

3.4 Mounting the server to the rack

To mount the server to the rack:

1. Align the server rails with the rack rails.
Asus TS500-E5 — 3.4 Mounting the server to the rack diagram (page 54)
Fig. 75 · 3.4 Mounting the server to the rack
2. Push the server all the way into the rack.
Asus TS500-E5 — 3.4 Mounting the server to the rack diagram (page 54)
Fig. 76 · 3.4 Mounting the server to the rack
Chapter 3Installation options 3-4
Page 55 of the Asus TS500-E5 user manual — Chapter 4
Page 55 · click to enlarge
Page 55

Chapter 4

Motherboard info

This chapter includes the motherboard layout, and brief descriptions of the jumpers and internal connectors.

Page 56 of the Asus TS500-E5 user manual — 4.1 Motherboard layout
Page 56 · click to enlarge
Page 56

4.1 Motherboard layout

24.5cm (9.6in)

Asus TS500-E5 — 4.1 Motherboard layout diagram (page 56)
Fig. 77 · 4.1 Motherboard layout

24.5cm (9.6in)

Chapter 4Motherboard information 4-2
Page 57 of the Asus TS500-E5 user manual — Layout contents
Page 57 · click to enlarge
Page 57

Layout contents

1. Clear RTC RAM (CLRTC1) 4-4
2. VGA controller setting (3-pin VGA_SW1) 4-5
3. LAN controller setting (3-pin LAN_SW1, LAN_SW2) 4-5
4. CPU Fan control setting (3-pin CPUFAN_SEL1) 4-6
5. System Fan control setting (3-pin CHAFAN_SEL1) 4-6
6. IDE setting (3-pin IDE_SW1) 4-7
7. Force BIOS recovery setting (3-pin RECOVERY1) 4-7
8. Intel

® ICH9R SATA port S/W RAID setting (3-pin RAID_SEL1) 4-8

9. iBTN RAID setting (3-pin IBTN_SEL1) 4-8
1. Floppy disk drive connector (34-1 pin FLOPPY1) 4-9
2. Serial ATA connectors [black] (7-pin SATA1-6) 4-9
3. IDE connector (40-1 pin PRI_EIDE1) 4-10
4. SAS connectors [red] (7-pin SAS1-4), [blue] (7-pin SAS5-8) 4-11
5. Hard disk activity LED connector (4-pin HDLED1) 4-11
6. Serial General Purpose Input/Output connector (6-1 pin SGPIO1) 4-12
7. Serial General Purpose Input/Output connectors (6-1 pin SGPIO2/3) 4-12
8. USB connectors (10-1 pin USB34, USB56) 4-13
9. CPU and system fan connectors (4-pin CPU_FAN1/2, REAR_FAN1/2, FRNT_FAN1/2/3/4) 4-13
10. Serial port connectors (10-1 pin COM2) 4-14
11. Power supply SMBus connector (5-pin PSUSMB1) 4-14
12. SSI power connectors (24-pin ATXPWR1, 8-pin ATX12V1) 4-15
13. System panel connector [white] (20-1 pin PANEL1) 4-16
14. Auxiliary panel connector [black] (20-pin AUX_PANEL1) 4-17

Jumpers Page · Internal connectors Page

Page 58 of the Asus TS500-E5 user manual — DSAN-DX/TS500-E5 Clear RTC RAM
Page 58 · click to enlarge
Page 58

4.2 Jumpers

1. Clear RTC RAM (CLRTC1)

This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords.

To erase the RTC RAM:

1. Turn OFF the computer and unplug the power cord.
2. Move the jumper cap from pins 1–2 (default) to pins 2–3. Keep the cap on pins 2–3 for about 5–10 seconds, then move the cap back to pins 1–2.
3. Plug the power cord and turn ON the computer.
4. Hold down the key during the boot process and enter BIOS setup to re-enter data.
Asus TS500-E5 — 1. Clear RTC RAM (CLRTC1) diagram (page 58)
Fig. 78 · 1. Clear RTC RAM (CLRTC1)

Except when clearing the RTC RAM, never remove the cap on CLRTC jumper default position. Removing the cap will cause system boot failure!

If the steps above do not help, remove the onboard battery and move the jumper again to clear the CMOS RTC RAM data. After the CMOS clearance, reinstall the battery.

DSAN-DX/TS500-E5 Clear RTC RAM

Chapter 4Motherboard information 4-4
Page 59 of the Asus TS500-E5 user manual — DSAN-DX/TS500-E5 VGA setting
Page 59 · click to enlarge
Page 59

2. VGA controller setting (3-pin VGA_SW1)

This jumper allows you to enable or disable the onboard VGA controller. Set to pins 1–2 to activate the VGA feature.

Asus TS500-E5 — 2. VGA controller setting (3-pin VGA_SW1) diagram (page 59)
Fig. 79 · 2. VGA controller setting (3-pin VGA_SW1)

DSAN-DX/TS500-E5 VGA setting

3. LAN controller setting (3-pin LAN_SW1, LAN_SW2)

These jumpers allow you to enable or disable the onboard Broadcom® BCM5721 Gigabit LAN1/2 controller. Set to pins 1–2 to activate the Gigabit LAN feature.

Asus TS500-E5 — DSAN-DX/TS500-E5 VGA setting diagram (page 59)
Fig. 80 · DSAN-DX/TS500-E5 VGA setting
Page 60 of the Asus TS500-E5 user manual — 5. System Fan control setting (3-pin CHAFAN_SEL1)
Page 60 · click to enlarge
Page 60

4. CPU Fan control setting (3-pin CPUFAN_SEL1)

This jumper allows you to switch for fan pin selection. The CPUFAN_SEL1 jumper is for the CPU fans control. Set to pins 1–2 when using 4-pin fans or pins 2–3 when using 3-pin fans.

Asus TS500-E5 — 4. CPU Fan control setting (3-pin CPUFAN_SEL1) diagram (page 60)
Fig. 81 · 4. CPU Fan control setting (3-pin CPUFAN_SEL1)
  • If you use a 4-pin fan but set the jumper to pin 2-3, the fan you installed may not work.
  • If you use a 3-pin fan but set the jumper for a 4-pin fan, the fan controll will not work and the fan you installed will always run at full speed.

5. System Fan control setting (3-pin CHAFAN_SEL1)

This jumper allows you to switch for fan pin selection. The CHAFAN_SEL1 jumper is for the system fans control. Set to pins 1–2 when using 4-pin fans or pins 2–3 when using 3-pin fans.

Asus TS500-E5 — 5. System Fan control setting (3-pin CHAFAN_SEL1) diagram (page 60)
Fig. 82 · 5. System Fan control setting (3-pin CHAFAN_SEL1)
  • If you use a 4-pin fan but set the jumper to pin 2 – 3, the fan you installed may not work.
  • If you use a 3-pin fan but set the jumper for a 4-pin fan, the fan controll will not work and the fan you installed will always run at full speed.
Chapter 4Motherboard information 4-6
Page 61 of the Asus TS500-E5 user manual — DSAN-DX/TS500-E5 BIOS recovery setting
Page 61 · click to enlarge
Page 61

6. IDE setting (3-pin IDE_SW1)

This jumper allows you to enable or disable the onboard IDE connector. Set to pins 1–2 to activate the IDE connector.

Asus TS500-E5 — 6. IDE setting (3-pin IDE_SW1) diagram (page 61)
Fig. 83 · 6. IDE setting (3-pin IDE_SW1)

7. Force BIOS recovery setting (3-pin RECOVERY1)

This jumper allows you to quickly update or recover the BIOS settings when it becomes corrupted.

To update the BIOS:

1. Prepare a floppy disk that contains the original or latest BIOS for the motherboard (XXXXXX.ROM) and the AFUDOS.EXE utility.
2. Set the jumper to pins 2–3.
3. Insert the floppy disk then turn on the system to update the BIOS.
4. Shut down the system.
5. Set the jumper back to pins 1–2.
6. Turn on the system.
Asus TS500-E5 — 7. Force BIOS recovery setting (3-pin RECOVERY1) diagram (page 61)
Fig. 84 · 7. Force BIOS recovery setting (3-pin RECOVERY1)

DSAN-DX/TS500-E5 BIOS recovery setting

Use the AFUDOS uitility version 3.12 to flash the BIOS.

Page 62 of the Asus TS500-E5 user manual — 9. iBTN RAID setting (3-pin IBTN_SEL1)
Page 62 · click to enlarge
Page 62

8. Intel

® ICH9R SATA port S/W RAID setting (3-pin RAID_SEL1)

This jumper allows you to select the Serial ATA RAID configuration utility to use when you create disk arrays. Both utilities are supported by the Intel

® ICH9R. Place the jumper caps on pins 1–2 if you want to use the LSI Software RAID Configuration Utility (default); otherwise, place the jumper caps on pins 2–3 to use the Intel

® Matrix Storage Manager (IMSM).

Asus TS500-E5 — 8. Intel diagram (page 62)
Fig. 85 · 8. Intel

9. iBTN RAID setting (3-pin IBTN_SEL1)

This jumper allows you to select the RAID configuration utility to use when you create disk arrays. Place the jumper caps on pins 1–2 if you install a PIKE RAID card to the motherboard and want to use the LSI Logic MPT Setup Utility (default). Or you can place the jumper caps on pins 2–3 to create the LSI Mega RAID 5 by supported Intel

® ICH9R SATA controller.

Asus TS500-E5 — 9. iBTN RAID setting (3-pin IBTN_SEL1) diagram (page 62)
Fig. 86 · 9. iBTN RAID setting (3-pin IBTN_SEL1)
  • LSI Logic MPT Setup Utility is available only when you install a PIKE RAID card.
  • LSI Mega RAID 5 fucntion is available only when you place the iBTN to I_BTN1 socket.
Chapter 4Motherboard information 4-8
Page 63 of the Asus TS500-E5 user manual — SATA1
Page 63 · click to enlarge
Page 63

4.3 Internal connectors

1. Floppy disk drive connector (34-1 pin FLOPPY1)

This connector is for the provided floppy disk drive (FDD) signal cable. Insert one end of the cable to this connector, then connect the other end to the signal connector at the back of the floppy disk drive.

Pin 5 on the connector is removed to prevent incorrect cable connection when using a FDD cable with a covered Pin 5.

Asus TS500-E5 — 1. Floppy disk drive connector (34-1 pin FLOPPY1) diagram (page 63)
Fig. 87 · 1. Floppy disk drive connector (34-1 pin FLOPPY1)

FLOPPY NOTE:Orient the red markings on the floppy ribbon cable to PIN 1.

PIN1

DSAN-DX/TS500-E5 Floppy disk drive connector

2. Serial ATA connectors [black] (7-pin SATA1-6)

These connectors, controlled by southbridge ICH9R, are for the Serial ATA signal cables for Serial ATA hard disk drives.

Asus TS500-E5 — PIN1 diagram (page 63)
Fig. 88

SATA1

GND RSATA_TXP1 RSATA_TXN1

SATA2 GND RSATA_1TXP2

RSATA_TXN2

GND RSATA_RXN1 RSATA_RXP1

GND RSATA_RXN2 RSATA_RXP2

GND

GND

SATA3

GND RSATA_TXP3 RSATA_TXN3

SATA4 GND RSATA_TXP4 RSATA_TXN4

GND RSATA_RXN3 RSATA_RXP3

GND RSATA_RXN4 RSATA_RXP4

GND

GND

SATA5

GND RSATA_TXP5 RSATA_TXN5

SATA6 GND RSATA_TXP6 RSATA_TXN6

GND RSATA_RXN5 RSATA_RXP5

GND RSATA_RXN6 RSATA_RXP6

GND

GND

DSAN-DX/TS500-E5 SATA connectors

Page 64 of the Asus TS500-E5 user manual — DSAN-DX/TS500-E5 IDE connector
Page 64 · click to enlarge
Page 64

3. IDE connector (40-1 pin PRI_EIDE1)

This connector is for an Ultra DMA 100/66 signal cable. The Ultra DMA 100/66 signal cable has three connectors: a blue connector for the primary IDE connector on the motherboard, a black connector for an Ultra DMA 100/66 IDE slave device (optical drive/hard disk drive), and a gray connector for an Ultra DMA 100/66 IDE master device (hard disk drive). If you install two hard disk drives, you must configure the second drive as a slave device by setting its jumper accordingly. Refer to the hard disk documentation for the jumper settings.

  • Pin 20 on the IDE connector is removed to match the covered hole on the Ultra DMA cable connector. This prevents incorrect insertion when you connect the IDE cable.
  • Use the 80-conductor IDE cable for Ultra DMA 100/66 IDE devices.
  • The onboard IDE connector is designed for ODD only (PATA).
Asus TS500-E5 — 3. IDE connector (40-1 pin PRI_EIDE1) diagram (page 64)
Fig. 89 · 3. IDE connector (40-1 pin PRI_EIDE1)

DSAN-DX/TS500-E5 IDE connector

Chapter 4Motherboard information 4-10
Page 65 of the Asus TS500-E5 user manual — DSAN-DX/TS500-E5 Storage card activity LED connector
Page 65 · click to enlarge
Page 65

4. SAS connectors [red] (7-pin SAS1-4), [blue] (7-pin SAS5-8)

This motherboard comes with eight (8) Serial Attached SCSI (SAS) connectors, the next-generation storage technology that supports both Series SCSI and Serial ATA (SATA). Each connector supports one device.

  • These connectors function only when you install a PIKE RAID card.
  • Connect the SAS hard disk drives to SAS connectors 1–4 when installing a 4-port PIKE RAID card.
Asus TS500-E5 — 4. SAS connectors [red] (7-pin SAS1-4), [blue] (7-pin SAS5-8) diagram (page 65)
Fig. 90 · 4. SAS connectors [red] (7-pin SAS1-4), [blue] (7-pi…

SAS4

SAS3

SAS2

SAS1

GND RSATA_TXP4 RSATA_TXN4

GND RSATA_TXP3 RSATA_TXN3

GND RSATA_TXP2 RSATA_TXN2

GND RSATA_TXP1 RSATA_TXN1

GND RSATA_RXN4 RSATA_RXP 4

GND RSATA_RXN3 RSATA_RXP3

GND RSATA_RXN2 RSATA_RXP2

GND RSATA_RXN1 RSATA_RXP1

GND

GND

GND

GND

SAS8

SAS7

SAS6

SAS5

GND RSATA_TXP8 RSATA_TXN8

GND RSATA_TXP7 RSATA_TXN7

GND RSATA_TXP6 RSATA_TXN6

GND RSATA_TXP5 RSATA_TXN5

GND RSATA_RXN8 RSATA_RXP8

GND RSATA_RXN7 RSATA_RXP7

GND RSATA_RXN6 RSATA_RXP6

GND RSATA_RXN5 RSATA_RXP5

GND

GND

GND

GND

5. Hard disk activity LED connector (4-pin HDLED1)

This connector is used to connect to a hard disk drive active LED connector on the SCSI or RAID card.

Asus TS500-E5 — SAS4 diagram (page 65)
Fig. 91

DSAN-DX/TS500-E5 Storage card activity LED connector

DSAN-DX/TS500-E5 SAS connectors

Page 66 of the Asus TS500-E5 user manual — SIO_DOUT
Page 66 · click to enlarge
Page 66

6. Serial General Purpose Input/Output connector (6-1 pin SGPIO1)

This connector is used for the SGPIO peripherals for the LSI MegaRAID SATA LED.

Asus TS500-E5 — 6. Serial General Purpose Input/Output connector (6-1 pin SGPIO1) diagram (page 66)
Fig. 92 · 6. Serial General Purpose Input/Output connector (6-…

DSAN-DX/TS500-E5 SGPIO connector

7. Serial General Purpose Input/Output connectors (6-1 pin SGPIO2/3)

These connector is used for the SAS chip SIO interface that controls the LED pattern generation, device information and general purpose data.

Asus TS500-E5 — DSAN-DX/TS500-E5 SGPIO connector diagram (page 66)
Fig. 93 · DSAN-DX/TS500-E5 SGPIO connector

SIO_DOUT

SIO_DOUT

SIO_DIN

SIO_DIN

GND

GND

SGPIO3

SGPIO2

PIN 1

PIN 1

GND

GND

SIO_END

SIO_CLK

GND

GND

SIO_END

SIO_CLK

DSAN-DX/TS500-E5 SGPIO2/3 connectors

These connectors functions only when you install a PIKE SAS RAID card.

Chapter 4Motherboard information 4-12
Page 67 of the Asus TS500-E5 user manual — DSAN-DX/TS500-E5 FAN connectors
Page 67 · click to enlarge
Page 67

8. USB connectors (10-1 pin USB34, USB56)

These connectors is for USB 2.0 ports. Connect the USB module cable to the connectors, then install the module to a slot opening at the back of the system chassis. The USB connectors comply with USB 2.0 specification that supports up to 480 Mbps connection speed.

Asus TS500-E5 — 8. USB connectors (10-1 pin USB34, USB56) diagram (page 67)
Fig. 94 · 8. USB connectors (10-1 pin USB34, USB56)

USB56

USB34

NC GND USB_P6+

NC GND USB_P4+

GND USB_P5+ USB_P5USB+5V

GND USB_P3+ USB_P3USB+5V

USB_P6-

USB+5V

USB_P4-

USB+5V

PIN 1

PIN 1

DSAN-DX/TS500-E5 USB 2.0 connectors

The USB port module is purchased separately.

9. CPU and system fan connectors (4-pin CPU_FAN1/2, REAR_FAN1/2, FRNT_FAN1/2/3/4)

The fan connectors support cooling fans of 350 mA–740 mA (8.88 W max.) or a total of 3.15 A–6.66 A (53.28 W max.) at +12V. Connect the fan cables to the fan connectors on the motherboard, making sure that the black wire of each cable matches the ground pin of the connector.

Asus TS500-E5 — 9. CPU and system fan connectors (4-pin CPU_FAN1/2, REAR_FAN1/2, FRNT_FAN1/2/3/4) diagram (page 67)
Fig. 95 · 9. CPU and system fan connectors (4-pin CPU_FAN1/2,…

DO NOT forget to connect the fan cables to the fan connectors. Insufficient air flow inside the system may damage the motherboard components. These are not jumpers! DO NOT place jumper caps on the fan connectors!

DSAN-DX/TS500-E5 FAN connectors

Page 68 of the Asus TS500-E5 user manual — DSAN-DX/TS500-E5 Power supply SMBus connector
Page 68 · click to enlarge
Page 68

10. Serial port connector (10-1 pin COM2)

This connector is for a serial (COM) port. Connect the serial port module cable to this connector, then install the module to a slot opening at the back of the system chassis.

Asus TS500-E5 — 10. Serial port connector (10-1 pin COM2) diagram (page 68)
Fig. 96 · 10. Serial port connector (10-1 pin COM2)

11. Power supply SMBus connector (5-pin PSUSMB1)

This connector is for the power supply SMB cable, if your power supply supports the SMBus function.

Asus TS500-E5 — 11. Power supply SMBus connector (5-pin PSUSMB1) diagram (page 68)
Fig. 97 · 11. Power supply SMBus connector (5-pin PSUSMB1)

DSAN-DX/TS500-E5 Power supply SMBus connector

Chapter 4Motherboard information 4-14
Page 69 of the Asus TS500-E5 user manual — DSAN-DX/TS500-E5 ATX power connectors
Page 69 · click to enlarge
Page 69

12. SSI power connectors (24-pin ATXPWR1, 8-pin ATX12V1)

These connectors are for SSI power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit.

  • For a fully configured system, we recommend that you use an SSI 12 V-compliant power supply unit (PSU) for LGA771‑socket Intel ® Xeon Dual Core processors (Bensley platform).
  • DO NOT forget to connect the 24+8-pin power plugs; otherwise, the system will not boot up.
  • Use of a PSU with a higher power output is recommended when configuring a system with more power consuming devices. The system may become unstable or may not boot up if the power is inadequate.
  • You must install a PSU with a higher power rating if you intend to install additional devices.
Asus TS500-E5 — 12. SSI power connectors (24-pin ATXPWR1, 8-pin ATX12V1) diagram (page 69)
Fig. 98 · 12. SSI power connectors (24-pin ATXPWR1, 8-pin ATX1…

DSAN-DX/TS500-E5 ATX power connectors

Page 70 of the Asus TS500-E5 user manual — DSAN-DX/TS500-E5 System panel connector
Page 70 · click to enlarge
Page 70

13. System panel connector [white] (20-pin PANEL1)

This connector supports several chassis-mounted functions.

Asus TS500-E5 — 13. System panel connector [white] (20-pin PANEL1) diagram (page 70)
Fig. 99 · 13. System panel connector [white] (20-pin PANEL1)

DSAN-DX/TS500-E5 System panel connector

1. System power LED (3-pin PLED) This 3-pin connector is for the system power LED. Connect the chassis power LED cable to this connector. The system power LED lights up when you turn on the system power, and blinks when the system is in sleep mode.
2. Message LED (2-pin MLED) This 2-pin connector is for the message LED cable that connects to the front message LED. The message LED is controlled by Hardware monitor to indicate an abnormal event occurance.
3. System warning speaker (4-pin SPEAKER) This 4-pin connector is for the chassis-mounted system warning speaker. The speaker allows you to hear system beeps and warnings.
4. Hard disk drive activity LED (2-pin IDE_LED) This 2-pin connector is for the HDD Activity LED. Connect the HDD Activity LED cable to this connector. The IDE LED lights up or flashes when data is read from or written to the HDD.
5. ATX power button/soft-off button (2-pin PWRSW) This connector is for the system power button. Pressing the power button turns the system on or puts the system in sleep or soft-off mode depending on the BIOS settings. Pressing the power switch for more than four seconds while the system is ON turns the system OFF.
6. Reset button (2-pin RESET) This 2-pin connector is for the chassis-mounted reset button for system reboot without turning off the system power.
Chapter 4Motherboard information 4-16
Page 71 of the Asus TS500-E5 user manual — I2C_4_CLK#
Page 71 · click to enlarge
Page 71

14. Auxiliary panel connector [black] (20-pin AUX_PANEL1)

This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs.

Asus TS500-E5 — 14. Auxiliary panel connector [black] (20-pin AUX_PANEL1) diagram (page 71)
Fig. 100 · 14. Auxiliary panel connector [black] (20-pin AUX_PA…

I2C_4_CLK#

I2C_4_DATA#

LAN1_LINK

LAN1_ACT

LAN2_ACT

LAN2_LINK

+5VSB

GND

NC

AUX_PANEL1

PIN 1

+5VSB

CASEOPEN

GND

LOCATORLED1+

LOCATORLED1-

LOCATORBTN#

GND

LOCATORLED2-

LOCATORLED2+

DSAN-DX/TS500-E5 Auxiliary panel connector

1. Front panel SMB (6-1 pin FPSMB) These leads connect the front panel SMBus cable.
2. LAN activity LED (2-pin LAN1_LED, LAN2_LED) These leads are for Gigabit LAN activity LEDs on the front panel.
3. Chassis intrusion (4-1 pin CHASSIS) These leads are for the intrusion detection feature for chassis with intrusion sensor or microswitch. When you remove any chassis component, the sensor triggers and sends a high-level signal to these leads to record a chassis intrusion event. The default setting is short CASEOPEN and GND pin by jumper cap to disable the function.
4. Locator LED (2-pin LOCATORLED1 and 2-pin LOCATORLED2) These leads are for the locator LED1 and LED2 on the front panel. Connect the Locator LED cables to these 2-pin connector. The LEDs will light up when the Locator button is pressed.
5. Locator Button/Swich (2-pin LOCATORBTN) These leads are for the locator button on the front panel. This button queries the state of the system locator.
Page 72 of the Asus TS500-E5 user manual — 4.3 Internal connectors
Page 72 · click to enlarge
Page 72
Chapter 4Motherboard information 4-18
Page 73 of the Asus TS500-E5 user manual — BIOS setup
Page 73 · click to enlarge
Page 73

Chapter 5

This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.

BIOS setup

Page 74 of the Asus TS500-E5 user manual — 5.1.1 Creating a bootable floppy disk
Page 74 · click to enlarge
Page 74

5.1 Managing and updating your BIOS

The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup:

1. AFUDOS utility (Updates the BIOS in DOS mode using a bootable floppy disk.)
2. ASUS CrashFree BIOS 3 (To recover the BIOS using a bootable floppy disk when the BIOS file fails or gets corrupted.)

Refer to the corresponding sections for details on these utilities.

Save a copy of the original motherboard BIOS file to a bootable floppy disk in case you need to restore the BIOS in the future. Copy the original motherboard BIOS using the ASUS Update or AFUDOS utilities.

5.1.1 Creating a bootable floppy disk

1. Do either one of the following to create a bootable floppy disk.

a. Insert a 1.44MB floppy disk into the drive.

b. At the DOS prompt, type format A:/S then press .

a. Insert a 1.44 MB floppy disk to the floppy disk drive.

b. Click Start from the Windows

® desktop, then select My Computer.

c. Select the 3 ½ Floppy Drive icon.

d. Right click File from the menu, then select Format. A Format 3½ Floppy Disk window appears.

e. Select Create an MS-DOS startup disk from the format options field, then click Start.

5-2 Chapter 5BIOS setup

DOS environment · Windows · ® environment

Page 75 of the Asus TS500-E5 user manual — afudos /o[filename]
Page 75 · click to enlarge
Page 75

5.1.2 AFUDOS utility

The AFUDOS utility allows you to update the BIOS file in DOS environment using a bootable floppy disk with the updated BIOS file. This utility also allows you to copy the current BIOS file that you can use as backup when the BIOS fails or gets corrupted during the updating process.

Copying the current BIOS

To copy the current BIOS file using the AFUDOS utility:

  • Make sure that the floppy disk is not write-protected and has at least 1024 KB free space to save the file.
  • The succeeding BIOS screens are for reference only. The actual BIOS screen displays may not be the same as shown.
1. Copy the AFUDOS utility (afudos.exe) from the motherboard support CD to the bootable floppy disk you created earlier.
2. Boot the system in DOS mode, then at the prompt type:

afudos /o[filename]

where the [filename] is any user-assigned filename not more than eight alphanumeric characters for the main filename and three alphanumeric characters for the extension name.

A:\>afudos /oOLDBIOS1.rom

Main filename Extension name

3. Press . The utility copies the current BIOS file to the floppy disk.

A:\>afudos /oOLDBIOS1.rom AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB)) Copyright (C) 2002 American Megatrends, Inc. All rights reserved. Reading flash done Write to file ok A:\>

The utility returns to the DOS prompt after copying the current BIOS file.

Page 76 of the Asus TS500-E5 user manual — afudos /i[filename]
Page 76 · click to enlarge
Page 76

Updating the BIOS file

To update the BIOS file using the AFUDOS utility:

1. Visit the ASUS website (www.asus.com) and download the latest BIOS file for the motherboard. Save the BIOS file to a bootable floppy disk.

Write the BIOS filename on a piece of paper. You need to type the exact BIOS filename at the DOS prompt.

2. Copy the AFUDOS utility (afudos.exe) from the motherboard support CD to the bootable floppy disk you created earlier.
3. Boot the system in DOS mode, then at the prompt, type:

afudos /i[filename]

where [filename] is the latest or the original BIOS file on the bootable floppy disk, then press .

A:\>afudos /iTS500-E5.ROM

The utility verifies the file, then starts updating the BIOS file.

A:\>afudos /iTS500-E5.ROM AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB)) Copyright (C) 2002 American Megatrends, Inc. All rights reserved. WARNING!! Do not turn off power during flash BIOS Reading file done Reading flash done

Advance Check Erasing flash done Writing flash 0x0008CC00 (9%)

DO NOT shut down or reset the system while updating the BIOS to prevent system boot failure!

5-4 Chapter 5BIOS setup
Page 77 of the Asus TS500-E5 user manual — A:\>
Page 77 · click to enlarge
Page 77
5. The utility returns to the DOS prompt after the BIOS update process is completed. Reboot the system from the hard disk drive.

A:\>afudos /iTS500-E5.ROM AMI Firmware Update Utility - Version 1.19(ASUS V2.07(03.11.24BB)) Copyright (C) 2002 American Megatrends, Inc. All rights reserved. WARNING!! Do not turn off power during flash BIOS Reading file done Reading flash done Advance Check Erasing flash done Writing flash done Verifying flash done

Please restart your computer

A:\>

Updating the BIOS file using a USB flash drive

If you have not purchased a USB floppy disk drive, you may update the BIOS file using a USB flash drive. Format the USB flash drive to FAT16 or 32 system file before updating the BIOS.

To format the USB flash drive to a FAT32/16 system file:

1. Insert the USB flash drive to an available USB port.
2. From the Windows desktop, click Start , then select My Computer .
3. Right-click the USB flash drive icon, then select Format from the menu.
4. From the File system field, select FAT32 or FAT16 , then click the Start button.

To update the BIOS file:

1. Copy the original or the latest BIOS file and the AFUDOS utility (afudos.exe) to the USB flash drive.
2. Insert the USB flash drive to an available USB port, then place the motherboard support CD to the optical drive.
3. Boot the system from the support CD, then select the FreeDOS command prompt .
4. At the DOS prompt, replace the prompt with the USB flash disk drive letter, then type: afudos /i[filename].
5. Follow the instructions in the previous section to update the BIOS file.
Page 78 of the Asus TS500-E5 user manual — Recovering the BIOS from a USB flash drive
Page 78 · click to enlarge
Page 78

5.1.3 ASUS CrashFree BIOS 3 utility

The ASUS CrashFree BIOS 3 is an auto recovery tool that allows you to restore the BIOS file when it fails or gets corrupted during the updating process. You can update a corrupted BIOS file using a floppy disk or a USB flash drive that contains the updated BIOS file.

Prepare a floppy disk or a USB flash drive containing the updated motherboard BIOS before using this utility.

Recovering the BIOS from a floppy disk

To recover the BIOS from a floppy disk:

1. Turn on the system.
2. Insert the floppy disk with the original or updated BIOS file to the floppy disk drive.
3. The utility will automatically recover the BIOS. It resets the system when the BIOS recovery finished.

Recovering the BIOS from a USB flash drive

To recover the BIOS from a USB flash drive:

1. Remove any floppy disk from the floppy disk drive and turn the system.
2. Insert the USB flash drive with the original or updated BIOS file to one USB port on the system.
3. The utility will automatically recover the BIOS. It resets the system when the BIOS recovery finished.

DO NOT shut down or reset the system while recovering the BIOS! Doing so would cause system boot failure!

The recovered BIOS may not be the latest BIOS version for this motherboard. Visit the ASUS website (www.asus.com) to download the latest BIOS file.

5-6 Chapter 5BIOS setup
Page 79 of the Asus TS500-E5 user manual — 5.2 BIOS setup program
Page 79 · click to enlarge
Page 79

5.2 BIOS setup program

This motherboard supports a programmable Low-Pin Count (LPC) chip that you can update using the provided utility described in section 5.1 Managing and updating your BIOS.

Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to “Run Setup.” This section explains how to configure your system using this utility.

Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future. For example, you can enable the security password feature or change the power management settings. This requires you to reconfigure your system using the BIOS Setup program so that the computer can recognize these changes and record them in the CMOS RAM of the LPC chip.

The LPC chip on the motherboard stores the Setup utility. When you start up the computer, the system provides you with the opportunity to run this program. Press during the Power-On Self-Test (POST) to enter the Setup utility; otherwise, POST continues with its test routines.

If you wish to enter Setup after POST, restart the system by pressing , or by pressing the reset button on the system chassis. You can also restart by turning the system off and then back on. Do this last option only if the first two failed.

The Setup program is designed to make it as easy to use as possible. Being a menu-driven program, it lets you scroll through the various sub-menus and make your selections from the available options using the navigation keys.

  • The default BIOS settings for this motherboard apply for most conditions to ensure optimum performance. If the system becomes unstable after changing any BIOS settings, load the default settings to ensure system compatibility and stability. Select the Load Default Settings item under the Exit Menu. See section 5.8 Exit Menu .
  • The BIOS setup screens shown in this section are for reference purposes only, and may not exactly match what you see on your screen.
  • Visit the ASUS website (<a href="http://www.asus.com" rel="nofollow noopener" target="_blank">www.asus.com</a>) to download the latest BIOS file for this motherboard.
Page 80 of the Asus TS500-E5 user manual — 5.2.3 Navigation keys
Page 80 · click to enlarge
Page 80

5.2.1 BIOS menu screen

Configuration fields Menu items

General help Menu bar

BIOS SETUP UTILITY Main Advanced Server Power Boot Exit

System Time [13:44:30] System Date [Tue, 10/11/2007] Legacy Diskette [1.44 MB, 3.5 in.]

Use [ENTER], [TAB] or [SHIFT-TAB] to select a field.

Use [+] or [-] to configure system Date.

SATA1 : [Not Detected] SATA2 : [Not Detected] SATA3 : [Not Detected] SATA4 : [Not Detected] SATA5 : [Not Detected] SATA6 : [Not Detected] PATA Master : [Not Detected] PATA Slvae : [Not Detected] IDE Configuration

←→ Select Screen ↑↓ Select Item +- Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

5.2.2 Menu bar

The menu bar on top of the screen has the following main items:

Main For changing the basic system configuration

Advanced For changing the advanced system settings

Server For changing the advanced server settings

Power For changing the advanced power management (APM) configuration

Boot For changing the system boot configuration

Exit For selecting the exit options and loading default settings

To select an item on the menu bar, press the right or left arrow key on the keyboard until the desired item is highlighted.

5.2.3 Navigation keys

At the bottom right corner of a menu screen are the navigation keys for that particular menu. Use the navigation keys to select items in the menu and change the settings.

Some of the navigation keys differ from one screen to another.

5-8 Chapter 5BIOS setup

System Information · Sub-menu items · Navigation keys

Page 81 of the Asus TS500-E5 user manual — 5.2.9 General help
Page 81 · click to enlarge
Page 81

5.2.4 Menu items

The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main shows the Main menu items.

Asus TS500-E5 — 5.2.4 Menu items diagram (page 81)
Fig. 101 · 5.2.4 Menu items

System Time [11:17:09] System Date [Tue 01/22/2008] Legacy Diskette A [1.44 MB 3.5 in.]

select a field.

Use [+] or [-] to

Date.

PATA Master [Not Detected]

PATA Slave [Not Detected]

The other items (Advanced, Power, Boot, and Exit) on the menu bar have their respective menu items.

5.2.5 Sub-menu items

A solid triangle before each item on any menu screen means that the item has a sub-menu. To display the sub-menu, select the item and press .

5.2.6 Configuration fields

These fields show the values for the menu items. If an item is user-configurable, you can change the value of the field opposite the item. You cannot select an item that is not user-configurable.

A configurable field is enclosed in brackets, and is highlighted when selected. To change the value of a field, select it then press to display a list of options. Refer to 5.2.7 Pop-up window.

5.2.7 Pop-up window

Select a menu item then press to display a pop-up window with the configuration options for that item.

5.2.8 Scroll bar

Asus TS500-E5 — 5.2.8 Scroll bar diagram (page 81)
Fig. 102 · 5.2.8 Scroll bar

A scroll bar appears on the right side of a menu screen when there are items that do not fit on the screen. Press the Up/Down arrow keys or / keys to display the other items on the screen.

5.2.9 General help

At the top right corner of the menu screen is a brief description of the selected item.

Show 14 more labels / short text on this page
Use [ENTER], [TAB] · or [SHIFT-TAB] to · SATA1 [Not Detected] · SATA2 [Not Detected] · SATA3 [Not Detected]] · configure system · SATA4 [Not Detected] · SATA5 [Not Detected] · SATA6 [Not Detected] · IDE Configuration · System Information · Main menu items · Pop-up window · Scroll bar
Page 82 of the Asus TS500-E5 user manual — 5.3.3 Legacy Diskette A [Disabled]
Page 82 · click to enlarge
Page 82

5.3 Main menu

When you enter the BIOS Setup program, the Main menu screen appears, giving you an overview of the basic system information.

Refer to section 5.2.1 BIOS menu screen for information on the menu screen items and how to navigate through them.

BIOS SETUP UTILITY Main Advanced Server Power Boot Exit

System Time [13:44:30] System Date [Tue, 10/11/2007] Legacy Diskette A [Disabled]

Use [ENTER], [TAB] or [SHIFT-TAB] to select a field.

Use [+] or [-] to configure system Date.

SATA1 : [Not Detected] SATA2 : [Not Detected] SATA3 : [Not Detected] SATA4 : [Not Detected] SATA5 : [Not Detected] SATA6 : [Not Detected] PATA Master : [Not Detected] PATA Slvae : [Not Detected] IDE Configuration

←→ Select Screen ↑↓ Select Item +- Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

5.3.1 System Time [xx:xx:xx]

Allows you to set the system time.

5.3.2 System Date [Day xx/xx/xxxx]

Allows you to set the system date.

5.3.3 Legacy Diskette A [Disabled]

Sets the type of floppy drive installed. Configuration options: [Disabled] [360 KB, 5.25 in.] [1.2 MB, 5.25 in.] [720 KB, 3.5 in.] [1.44 MB, 3.5 in] [2.88 MB, 3.5 in]

5-10 Chapter 5BIOS setup

System Information

Page 83 of the Asus TS500-E5 user manual — Block (Multi-Sector Transfer) M [Auto]
Page 83 · click to enlarge
Page 83

5.3.4 SATA1–6; PATA Master/Slave

The BIOS automatically detects the connected IDE devices. There is a separate sub-menu for each IDE device. Select a device item, then press to display the IDE device information.

The PATA device is for ODD (optical disk drive) only.

BIOS SETUP UTILITY Main

Primary IDE Master Device :Hard Disk Vendor :xxxxxxxxx Size :xx.xGB LBA Mode :Supported Block Mode:16Sectors PIO Mode :4 Async DMA :MultiWord DMA-2 Ultra DMA :Ultra DMA-6 S.M.A.R.T.:Supported

Select the type of device connected to the system.

←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

Type [Auto] LBA/Large Mode [Auto] Block(Multi-Sector Transfer)M [Auto] PIO Mode [Auto] DMA Mode [Auto] SMART Monitoring [Auto] 32Bit Data Transfer [Enabled]

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

The BIOS automatically detects the values opposite the dimmed items (Device, Vendor, Size, LBA Mode, Block Mode, PIO Mode, Async DMA, Ultra DMA, and S.M.A.R.T. monitoring). These values are not user-configurable. These items show N/A if no IDE device is installed in the system.

Type [Auto]

Selects the type of IDE drive. Setting to [Auto] allows automatic selection of the appropriate IDE device type. Select [CDROM] if you are specifically configuring a CD-ROM drive. Select [ARMD] (ATAPI Removable Media Device) if your device is either a ZIP, LS-120, or MO drive. Configuration options: [Not Installed] [Auto] [CD/DVD] [ARMD]

LBA/Large Mode [Auto]

Enables or disables the LBA mode. Setting to [Auto] enables the LBA mode if the device supports this mode, and if the device was not previously formatted with LBA mode disabled. Configuration options: [Disabled] [Auto]

Block (Multi-Sector Transfer) M [Auto]

Enables or disables data multi-sectors transfers. When set to [Auto], the data transfer from and to the device occurs multiple sectors at a time if the device supports multi-sector transfer feature. When set to [Disabled], the data transfer from and to the device occurs one sector at a time. Configuration options: [Disabled] [Auto]

Page 84 of the Asus TS500-E5 user manual — 32Bit Data Transfer [Enabled]
Page 84 · click to enlarge
Page 84

PIO Mode [Auto]

Allows you to select the data transfer mode. Configuration options: [Auto] [0] [1] [2] [3] [4]

DMA Mode [Auto]

Sets the DMA mode. Configuration options: [Auto] [SWDMA0] [SWDMA1] [SWDMA2] [MWDMA0] [MWDMA1] [MWDMA2] [UDMA0] [UDMA1] [UDMA2] [UDMA3] [UDMA4] [UDMA5] [UDMA6]

SMART Monitoring [Auto]

Sets the Smart Monitoring, Analysis, and Reporting Technology. Configuration options: [Auto] [Disabled] [Enabled]

32Bit Data Transfer [Enabled]

Enables or disables 32-bit data transfer. Configuration options: [Disabled] [Enabled]

5-12 Chapter 5BIOS setup
Page 85 of the Asus TS500-E5 user manual — Hard Disk Write Protect [Disabled]
Page 85 · click to enlarge
Page 85

5.3.5 IDE Configuration

The items in this menu allow you to set or change the configurations for the IDE devices installed in the system. Select an item then press if you wish to configure the item.

BIOS SETUP UTILITY Main

SATA#1 Configuration [Enhanced] Configure SATA#1 as [IDE] SATA#2 Configuration [Enhanced]

Hard Disk Write Protect [Disabled]

←→ Select Screen ↑↓ Select Item +- Change Field F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

SATA#1–2 Configuration [Enhanced]

Configuration options[Disabled] [Compatible] [Enhanced]

Configure SATA#1 as [IDE] Sets the configuration for the Serial ATA connectors supported by the Southbridge chip. Configuration options: [IDE] [RAID] [AHCI]

If you want to create a RAID 0, RAID 1, RAID 5, RAID 10, or the Intel® Matrix Storage Technology configuration from the Serial ATA hard disk drives, set this item to [RAID].

If you want to use the Serial ATA hard disk drives as Parallel ATA physical storage devices, keep the default setting [IDE].

If you want the Serial ATA hard disk drives to use the Advanced Host Controller Interface (AHCI), set this item to [AHCI]. The [AHCI] option allows the onboard storage driver to enable advanced Serial ATA features that increases storage performance on random workloads by allowing the drive to internally optimize the order of commands.

Hard Disk Write Protect [Disabled]

Disables or enables device write protection. This will be effective only if device is accessed through BIOS. Configuration option: [Disabled] [Enabled]

IDE Configuration · Options · Disabled Compatible Enhanced

Page 86 of the Asus TS500-E5 user manual — System Memory
Page 86 · click to enlarge
Page 86

5.3.6 System Information

This menu gives you an overview of the general system specifications. The BIOS automatically detects the items in this menu.

BIOS SETUP UTILITY Main

AMIBIOS

Version0204 Build Date: 05/13/08
Speed1866MHz Count : 1

←→ Select Screen ↑↓ Select Item F1 General Help F10 Save and Exit ESC Exit

Usable Size2048MB

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

AMIBIOS

Displays the auto-detected BIOS information.

Processor

Displays the auto-detected CPU specification.

System Memory

Displays the auto-detected system memory.

5-14 Chapter 5BIOS setup

System Information · Processor · System Memory

Page 87 of the Asus TS500-E5 user manual — 5.4.1 USB Configuration
Page 87 · click to enlarge
Page 87

5.4 Advanced menu

The Advanced menu items allow you to change the settings for the CPU and other system devices.

Take caution when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction.

BIOS SETUP UTILITY Main Advanced Server Power Boot Exit

Configure the USB support. USB Configuration

CPU Configuration Chipset Onboard Devices Configuration PCIPnP

←→ Select Screen ↑↓ Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

5.4.1 USB Configuration

The items in this menu allows you to change the USB-related features. Select an item then press to display the configuration options.

BIOS SETUP UTILITY Advanced

Module Version - 2.24.3-13.4

USB Devices Enabled:

USB Functions [Enabled] Legacy USB Support [Enabled] USB 2.0 Controller Mode [HiSpeed] BIOS EHCI Hand-Off [Enabled] ←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

The USB Devices Enabled item shows the auto-detected values. If no USB device is detected, the item shows None.

Show 4 more labels / short text on this page
USB Configuration · Options · Disabled Enabled · None
Page 88 of the Asus TS500-E5 user manual — BIOS EHCI Hand-Off [Enabled]
Page 88 · click to enlarge
Page 88

USB Functions [Enabled]

Allows you to enable the USB host controller. Configuration options: [Disabled] [Enabled]

The following item appears only when you set USB Function to [Enabled].

Legacy USB Support [Enabled]

Allows you to enable or disable support for legacy USB devices. Setting to [Auto] allows the system to detect the presence of USB devices at startup. If detected, the USB controller legacy mode is enabled. If no USB device is detected, the legacy USB support is disabled. Configuration options: [Disabled] [Enabled] [Auto]

The following item appears only when you set USB Function to [Enabled].

USB 2.0 Controller Mode [HiSpeed]

Allows you to set the USB 2.0 controller to HiSpeed (480Mbps) or FullSpeed (12Mbps). Configuration options: [FullSpeed] [HiSpeed]

BIOS EHCI Hand-Off [Enabled]

Enables or disables the BIOS EHCI hand-off support. Configuration options: [Disabled] [Enabled]

5-16 Chapter 5BIOS setup
Page 89 of the Asus TS500-E5 user manual — *Adjacent Cache Line Prefetch [Enabled]
Page 89 · click to enlarge
Page 89

5.4.2 CPU Configuration

The items in this menu show the CPU-related information that the BIOS automatically detects. Some items may not appear if you CPU does not support the related functions.

BIOS SETUP UTILITY Advanced

Configure advanced CPU settings Module Version:3F.06 Manufacturer:Intel Brand String:Intel(R) Xeon(R) CPU 5150 Frequency :2.66GHz FSB Speed :1333 MHz Cache L1 :64 KB Cache L2 :4096 KB Ratio Status:Unlocked (Min:06, Max:08) Ratio Actual Value: 8

Sets the ratio between CPU Core Clock and the FSB Frequency. Note:If an invalid ratio is set in CMOS then actual and setpoint values may differ.

Ratio CMOS Setting [7] C1E Support [Enabled] Hardware Prefetcher [Enabled] Adjacent Cache Line Prefetch [Enabled] Max CPUID Value Limit [Disabled] Intel(R) Virtualization Tech [Enabled] Execute-Disable Bit Capability [Enabled] Core Multi-Processing [Enabled]

←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

Scroll down for more items.

Intel(R) SpeedStep(tm) tech. [Enabled]

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

Ratio CMOS Setting [7] Whether this item is configurable depends on your CPU type. The valid value ranges differently according to your CPU type. If this item is configurable, enter the value using the numeric keypad. This item is available only when Intel SpeedStep technology is disabled.

C1E Support [Enabled]

Allows you to enable or disable C1E support. Configuration options: [Disabled] [Enabled]

Hardware Prefetcher [Enabled]

Enable this item to use the Hardware Prefetcher Disable Feature. Configuration options: [Disabled] [Enabled]

*Adjacent Cache Line Prefetch [Enabled]

Enable this item to use the Adjacent Cache Line Prefetch Disable Feature. Configuration options: [Disabled] [Enabled]

Page 90 of the Asus TS500-E5 user manual — Intel(R) SpeedStep(tm) tech. [Enabled]
Page 90 · click to enlarge
Page 90

Max CPUID Value Limit [Disabled]

Setting this item to [Enabled] allows legacy operating systems to boot even without support for CPUs with extended CPUID functions. Configuration options: [Disabled] [Enabled]

Intel(R) Virtualization Tech [Enabled]

The Vanderpool Virtualization Technology allows a hardware platform to run multiple operating systems separately, enabling one system to virtually function as several systems. Configuration options: [Disabled] [Enabled]

Execute-Disable Bit Capability [Enabled]

Allows you to enable or disable the No-Execution Page Protection Technology. Setting this item to [Disabled] forces the XD feature flag to always return to zero (0). Configuration options: [Disabled] [Enabled]

Core Multi-Processing [Enabled]

Configuration options[Disabled] [Enabled]

Intel(R) SpeedStep(tm) tech. [Enabled]

Allows you to enable or disable the Intel SpeedStep Technology. Refer to the Appendix for more information on the Intel SpeedStep Technology. Configuration options: [Disabled] [Enabled]

Items above with * mark are for technical personnel to debug only.

5-18 Chapter 5BIOS setup
Page 91 of the Asus TS500-E5 user manual — MCH Channel Mode [Channel Interleave]
Page 91 · click to enlarge
Page 91

5.4.3 Chipset

The Chipset configuration menu allows you to change advanced chipset settings. Select an item then press to display the sub-menu.

BIOS SETUP UTILITY Advanced

Configure North Bridge features.

←→ Select Screen ↑↓ Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

North Bridge Configuration

The North Bridge Configuration menu allows you to change the Northbridge settings.

BIOS SETUP UTILITY Advanced

Crystal Beach / DMA [Disabled]

Crystal Beach / DMA configuration

MCH Channel Mode [Channel Interleave] Patrol Scrubbing [Enabled] Demand Scrubbing [Enabled] Channel Dependent Sparing [Disabled] Channel 0 [Enabled] Channel Specific Sparing [Disabled] Rank Interleaving [4:1] Channel 1 [Enabled] Channel Specific Sparing [Disabled] Rank Interleaving [4:1] Read Completion Coalescing [Auto]

←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

Crystal Beach / DMA [Disabled]

Allows you to do the Crystal Beach/DMA configuration. Configuration options: [Disabled] [Enabled]

MCH Channel Mode [Channel Interleave]

Allows you to select the MCH channel mode. Configuration options: [Channel Sequencing] [Channel Interleave] [Single Channel 0]

Advanced Chipset Settings · North Bridge Configuration

Page 92 of the Asus TS500-E5 user manual — Read Completion Coalescing [Auto]
Page 92 · click to enlarge
Page 92

Patrol Scrubbing [Enabled]

Enables or disables the Patrol Scrubbing. Configuration options: [Disabled] [Enabled]

Demand Scrubbing [Disabled]

Enables or disables the Demand Scrubbing. Configuration options: [Disabled] [Enabled]

Channel Dependent Sparing [Disabled]

Allows you to enable or disabled the channel-dependent DIMM sparing feature. Configuration options: [Disabled] [Enabled]

Channel 0 [Enabled]

Allows you to enable or disable the Channel 0. If you set this item to [Disabled], the following three items will be grayed out. Configuration options: [Disabled] [Enabled]

Channel Specific Sparing [Disabled]

Allows you to enable or disable the DIMM sparing feature. Configuration options: [Disabled] [Enabled]

Rank Interleaving [4:1]

Allows you to select the Channel 0 Rank Interleave. Configuration options: [1:1] [2:1] [4:1]

Channel 1 [Enabled]

Allows you to enable or disable the Channel 1. If you set this item to [Disabled], Channel 0 and the following two items will be grayed out. Configuration options: [Disabled] [Enabled]

Channel Specific Sparing [Disabled]

Allows you to enable or disable the DIMM sparing feature. Configuration options: [Disabled] [Enabled]

Rank Interleaving [4:1]

Allows you to select the Channel 1 Rank Interleave. Configuration options: [1:1] [2:1] [4:1]

Read Completion Coalescing [Auto]

Configuration options[Disabled] [Enabled] [Auto]
5-20 Chapter 5BIOS setup
Page 93 of the Asus TS500-E5 user manual — Onboard LAN1/2 Boot ROM [Enabled]
Page 93 · click to enlarge
Page 93

5.4.4 Onboard Device Configuration

BIOS SETUP UTILITY Advanced

Configure Win627EHF Super IO Chipset

Allows BIOS to Enable or Disable Floppy Controller.

Serial Port1 Address [3F8/IRQ4] Serial Port2 Address [2F8/IRQ3] Serial Port2 Mode [Normal]

OnBoard LAN1 Boot ROM [Enabled] OnBoard LAN2 Boot ROM [Enabled]

←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

Serial Port1 Address [3F8/IRQ4]

Allows you to select the Serial Port1 base address. Configuration options: [Disabled] [3F8/IRQ4] [3E8/IRQ4] [2E8/IRQ3]

Serial Port2 Address [2F8/IRQ3]

Allows you to select the Serial Port2 base address. Configuration options: [Disabled] [2F8/IRQ3] [3E8/IRQ4] [2E8/IRQ3]

Serial Port2 Mode [Normal]

Allows you to select the mode for Serial Port2. Configuration options: [Normal] [IrDA] [ASK IR]

IR I/O Pin Select [SINB/SOUTB] This item appears only when you set the Serial Port2 Mode item to [IrDa] or [ASK IR] and allows you to select the receiver or transmit pin for Serial Port2. Configuration options: [SINB/SOUTB] [IRRX/IRTX]

IR Duplex Mode [Half Duplex] This item appears only when you set the Serial Port2 Mode item to [IrDa] or [ASK IR] and allows you to select Full or Half Duplex for Serial Port2. Configuration options: [Full Duplex] [Half Duplex]

Onboard LAN1/2 Boot ROM [Enabled]

Allows you to do the LAN Boot ROM configuration. Configuration options: [Disabled] [Enabled]

Page 94 of the Asus TS500-E5 user manual — Palette Snooping [Disabled]
Page 94 · click to enlarge
Page 94

5.4.5 PCIPnP

The PCIPnP menu items allow you to change the advanced settings for PCI/PnP devices. The menu includes setting IRQ and DMA channel resources for either PCI/PnP or legacy ISA devices, and setting the memory size block for legacy ISA devices.

Take caution when changing the settings of the PCI/PnP Configuration menu items. Incorrect field values can cause the system to malfunction.

BIOS SETUP UTILITY Advanced

NO: lets the BIOS configure all the devices in the system. YES: lets the operating system configure Plug and Play (PnP) devices not required for boot if your system has a Plug and Play operating system.

Plug & Play O/S [No] PCI Latency Timer [64] Allocate IRQ to PCI VGA [Yes] Palette Snooping [Disabled]

←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

Plug And Play O/S [No]

When set to [No], BIOS configures all the devices in the system. When set to [Yes] and if you install a Plug and Play operating system, the operating system configures the Plug and Play devices not required for boot. Configuration options: [No] [Yes]

PCI Latency Timer [64]

Allows you to select the value in units of PCI clocks for the PCI device latency timer register. Configuration options: [32] [64] [96] [128] [160] [192] [224] [248]

Allocate IRQ to PCI VGA [Yes]

When set to [Yes], BIOS assigns an IRQ to PCI VGA card if the card requests for an IRQ. When set to [No], BIOS does not assign an IRQ to the PCI VGA card even if requested. Configuration options: [Yes] [No]

Palette Snooping [Disabled]

When set to [Enabled], the pallete snooping feature informs the PCI devices that an ISA graphics device is installed in the system so that the latter can function correctly. Configuration options: [Disabled] [Enabled]

5-22 Chapter 5BIOS setup

Advanced PCI/PnP Settings

Page 95 of the Asus TS500-E5 user manual — Remote Access [Enabled]
Page 95 · click to enlarge
Page 95

5.5 Server menu

BIOS SETUP UTILITY Main Advanced Server Power Boot Exit

Configure Remote Access.

ASF Support [Enabled] Remote Access Configuration

←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

5.5.1 ASF Support [Enabled]

Allows you to enable or disable the ASF support. Configuration options: [Disabled] [Enabled]

5.5.2 Remote Access Configuration

The items in this menu allows you to configure the Remote Access features. Select an item then press to display the configuration options.

BIOS SETUP UTILITY Server

Configure Remote Access type and parameters

Select Remote Access type.

Serial port number [COM2] Base Address, IRQ [2F8h, 3] Serial Port Mode [57600 8,n,1] Flow Control [Hardware] Redirection After BIOS POST [Disabled] Terminal Type [VT-UTF8] Sredir Memory Display Delay [No Delay]

←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

Remote Access [Enabled]

Enables or disables the remote access feature. Configuration options: [Disabled] [Enabled]

The following items appear only when Remote Access is set to [Enabled].

Remote Access [Enabled]

Page 96 of the Asus TS500-E5 user manual — Sredir Memory Display Delay [No Delay]
Page 96 · click to enlarge
Page 96

Serial port number [COM2]

Selects the serial port for console redirection. Configuration options: [COM1] [COM2]

Base Address. IRQ [2F8h, 3] This item is not user-configurable and changes with the configuration of Serial port number.

Serial port Mode [57600 8,n,1]

Sets the Serial port mode. Configuration options: [115200 8,n,1] [57600 8,n,1] [38400 8,n,1] [19200 8,n,1]

Flow Control [Hardware]

Allows you to select the flow control for console redirection. Configuration options: [None] [Hardware] [Software]

Redirection After BIOS POST [Disabled]

Sets the redirection mode after the BIOS Power-On Self-Test (POST). Some operating system may not work when set to [Always]. Configuration options: [Disabled] [Boot Loader] [Always]

Terminal Type [VT-UTF8]

Allows you to select the target terminal type. Configuration options: [ANSI] [VT100] [VT-UTF8]

VT-UTF8 Combo Key Support [Enabled]

Enables or disables the VT-UTF8 combo key support for ANSI or VT100 terminals. Configuration options: [Disabled] [Enabled]

Sredir Memory Display Delay [No Delay]

Sets the delay seconds to display memory information. Configuration options: [No Delay] [Delay 1 Sec] [Delay 2 Sec] [Delay 4 Sec]

5-24 Chapter 5BIOS setup
Page 97 of the Asus TS500-E5 user manual — 5.6.2 ACPI APIC Support [Enabled]
Page 97 · click to enlarge
Page 97

5.6 Power menu

The Power menu items allow you to change the settings for the Advanced Power Management (APM). Select an item then press to display the configuration options.

BIOS SETUP UTILITY Main Advanced Server Power Boot Exit

Add additional tables as per ACPI 2.0 specifications.

ACPI 2.0 Support [Disabled] ACPI APIC Support [Enabled]

APM Configuration Hardware Monitor

←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

5.6.1 ACPI 2.0 Support [Disabled]

Specifies the Advanced Configuration and Power Interface (ACPI) version supported. Configuration options: [Disabled] [Enabled]

5.6.2 ACPI APIC Support [Enabled]

Allows you to enable or disable the Advanced Configuration and Power Interface (ACPI) support in the Advanced Programmable Interrupt Controller (APIC). When set to Enabled, the ACPI APIC table pointer is included in the RSDT pointer list. Configuration options: [Disabled] [Enabled]

Page 98 of the Asus TS500-E5 user manual — Resume On RTC Alarm [Disabled]
Page 98 · click to enlarge
Page 98

5.6.3 APM Configuration

BIOS SETUP UTILITY Power

<Enter> to select whether or not to restart the system after AC power loss

Restore on AC Power Loss [Last State] Power On By External Modems [Disabled] Power On by PME [Disabled] Power On By RTC Alarm [Disabled]

←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

Restore on AC Power Loss [Last State]

When set to [Power Off], the system goes into off state after an AC power loss. When set to [Power On], the system will reboot after an AC power loss. When set to [Last State], the system goes into either off or on state, whatever the system state was before the AC power loss. Configuration options: [Power Off] [Power On] [Last State]

Power On By External Modems [Disabled]

This allows either settings of [Enabled] or [Disabled] for powering up the computer when the external modem receives a call while the computer is in Soft-off mode. Configuration options: [Disabled] [Enabled]

Setting this item to [Enabled] allows the computer to power up even when the Serial Port1/2 Address item in the Onboard Device Configuration menu is set to [Disabled]. See section 5.4.4 Onboard Device Configuration for details.

Resume On PME [Disabled]

When set to [Enabled], the system enables the PME to generate a wake event while the computer is in Soft-off mode. Configuration options: [Disabled] [Enabled]

Resume On RTC Alarm [Disabled]

Allows you to enable or disable RTC to generate a wake-up event. Configuration options: [Disabled] [Enabled]

5-26 Chapter 5BIOS setup
Page 99 of the Asus TS500-E5 user manual — Hardware Voltage Configuration
Page 99 · click to enlarge
Page 99

5.6.4 Hardware Monitor

BIOS SETUP UTILITY Power

Hardware Temperature Configuration Hardware Fan Configuration Hardawre Voltage Configuration

←→ Select Screen ↑↓ Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

Hardware Temperature Configuration

The Hardware Temperature Configuration menu provides an overview of the hardware temperature information. The BIOS automatically detects the items in this menu.

CPU1/CPU2 [xxxºC/xxxºF] System1/2 [xxxºC/xxxºF]

The onboard hardware monitor automatically detects and displays the motherboard and CPU temperatures. The CPU1 Temperature shows N/A if no processor is installed in CPU1 socket.

Hardware Fan Configuration

The Hardware Fan Configuration menu provides an overview of the hardware fan information. The BIOS automatically detects the items in this menu.

CPU FAN1/2; FRN FAN1/2/3/4; REAR FAN1/2 [xxxxRPM] or [N/A]

The onboard hardware monitor automatically detects and displays the CPU, front, and rear fan speed in rotations per minute (RPM). If the fan is not connected to the motherboard, the field shows N/A.

Hardware Voltage Configuration

The Hardware Voltage Configuration menu provides an overview of the hardware fan information. The BIOS automatically detects the items in this menu.

VCOREA/B, Vtt, VSEN1/2, 3VSEN, 12VSEN, 5VDD, 5VSB, VBAT

The onboard hardware monitor automatically detects the voltage output through the onboard voltage regulators.

Hardware Monitor

Page 100 of the Asus TS500-E5 user manual — 1st ~ xxth Boot Device [XXXXXXX]
Page 100 · click to enlarge
Page 100

5.7 Boot menu

The Boot menu items allow you to change the system boot options. Select an item then press to display the sub-menu.

BIOS SETUP UTILITY Main Advanced Server Power Boot Exit

Specifies the Boot Device Priority sequence.

Boot Settings Configuration Security

A virtual floppy disk drive (Floppy Drive B: ) may appear when you set the CD-ROM drive as the first boot device.

←→ Select Screen ↑↓ Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

5.7.1 Boot Device Priority

BIOS SETUP UTILITY Main Advanced Server SecuritBoot Exit

Specifies the Boot Device Priority sequence.

1st Boot Device [1st FLOPPY DRIVE] 2nd Boot Device [ATAPI CD-ROM] 3rd Boot Device [Network:MBA v10.0.] 4th Boot Device [Network:MBA v10.0.]

A device enclosed in parenthesis has been disabled in the corresponding type menu.

←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

1st ~ xxth Boot Device [XXXXXXX]

These items specify the boot device priority sequence from the available devices. The number of device items that appears on the screen depends on the number of devices installed in the system. Configuration options: [xxxxx Drive] [Disabled]

5-28 Chapter 5BIOS setup

Boot Device Priority · Boot Device Priority

Page 101 of the Asus TS500-E5 user manual — Hit ‘DEL‘ Message Display [Enabled]
Page 101 · click to enlarge
Page 101

5.7.2 Boot Settings Configuration

BIOS SETUP UTILITY Main Advanced Server Security Boot Exit

Allows BIOS to skip certain tests while booting. This will decrease the time needed to boot the system.

Quick Boot [Enabled] Full Screen Logo [Enabled] AddOn ROM Display Mode [Force BIOS] Bootup Num-Lock [On] PS/2 Mouse Support [Auto] Wait For ‘F1‘ If Error [Enabled] Hit ‘DEL‘ Message Display [Enabled] Interrupt 19 Capture [Enabled]

←→ Select Screen ↑↓ Select Item +- Change Option F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

Quick Boot [Enabled]

Enabling this item allows the BIOS to skip some power on self tests (POST) while booting to decrease the time needed to boot the system. When set to [Disabled], BIOS performs all the POST items. Configuration options: [Disabled] [Enabled]

Full Screen Logo [Enabled]

Allows you to enable or disable the full screen logo display feature. Configuration options: [Disabled] [Enabled]

Set this item to [Enabled] to use the ASUS MyLogo2™ feature.

AddOn ROM Display Mode [Force BIOS]

Allows you to set the display mode for Options ROM. Configuration options: [Force BIOS] [Keep Current]

Bootup Num-Lock [On]

Allows you to select the power-on state for the NumLock. Configuration options: [Off] [On]

PS/2 Mouse Support [Auto]

Allows you to enable or disable support for PS/2 mouse. Configuration options: [Disabled] [Enabled] [Auto]

Wait For ‘F1‘ If Error [Enabled]

When set to [Enabled], the system waits for the key to be pressed when error occurs. Configuration options: [Disabled] [Enabled]

Hit ‘DEL‘ Message Display [Enabled]

When set to [Enabled], the system displays the message “Press DEL to run Setup” during POST. Configuration options: [Disabled] [Enabled]

Boot Settings Configuration

Page 102 of the Asus TS500-E5 user manual — Change Supervisor Password
Page 102 · click to enlarge
Page 102

Interrupt 19 Capture [Enabled]

When set to [Enabled], this function allows the option ROMs to trap Interrupt 19. Configuration options: [Disabled] [Enabled]

5.7.3 Security

The Security menu items allow you to change the system security settings. Select an item then press to display the configuration options.

BIOS SETUP UTILITY Main Advanced Server Power Boot Tools Exit

<Enter> to change password. <Enter> again to disable password.

Supervisor PasswordNot Installed User Password : Not Installed

Change Supervisor Password Change User Password

←→ Select Screen ↑↓ Select Item Enter Change F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

Change Supervisor Password

Select this item to set or change the supervisor password. The Supervisor Password item on top of the screen shows the default Not Installed. After you set a password, this item shows Installed.

To set a Supervisor Password:

1. Select the Change Supervisor Password item and press .
2. From the password box, type a password composed of at least six letters and/or numbers, then press .
3. Confirm the password when prompted.

The message “Password Installed” appears after you successfully set your password.

To change the supervisor password, follow the same steps as in setting a user password.

To clear the supervisor password, select the Change Supervisor Password then press . The message “Password Uninstalled” appears.

If you forget your BIOS password, you can clear it by erasing the CMOS Real Time Clock (RTC) RAM. See section 4.2 Jumper for information on how to erase the RTC RAM.

5-30 Chapter 5BIOS setup

Security Settings

Page 103 of the Asus TS500-E5 user manual — Password Check [Setup]
Page 103 · click to enlarge
Page 103

After you have set a supervisor password, the other items appear to allow you to change other security settings.

BIOS SETUP UTILITY Main Advanced Server Power Boot Tools Exit

Supervisor PasswordInstalled User Password : Not Installed

<Enter> to change password. <Enter> again to disable password.

Change Supervisor Password User Access Level [Full Access] Change User Password Password Check [Setup]

User Access Level [Full Access]

This item allows you to select the access restriction to the Setup items. Configuration options: [No Access] [View Only] [Limited] [Full Access]

No Access prevents user access to the Setup utility.

View Only allows access but does not allow change to any field.

Limited allows changes only to selected fields, such as Date and Time.

Full Access allows viewing and changing all the fields in the Setup utility.

Change User Password

Select this item to set or change the user password. The User Password item on top of the screen shows the default Not Installed. After you set a password, this item shows Installed.

To set a User Password:

1. Select the Change User Password item and press .
2. On the password box that appears, type a password composed of at least six letters and/or numbers, then press .
3. Confirm the password when prompted.

The message “Password Installed” appears after you set your password successfully.

To change the user password, follow the same steps as in setting a user password.

Password Check [Setup]

When set to [Setup], BIOS checks for user password when accessing the Setup utility. When set to [Always], BIOS checks for user password both when accessing Setup and booting the system. Configuration options: [Setup] [Always]

Page 104 of the Asus TS500-E5 user manual — Load Setup Defaults
Page 104 · click to enlarge
Page 104

5.8 Exit menu

The Exit menu items allow you to load the optimal or failsafe default values for the BIOS items, and save or discard your changes to the BIOS items.

BIOS SETUP UTILITY Main Advanced Server Power Boot Exit

Exit system setup after saving the changes.

Exit & Save Changes Exit & Discard Changes Discard Changes

F10 key can be used for this operation.

←→ Select Screen ↑↓ Select Item Enter Go to Sub Screen F1 General Help F10 Save and Exit ESC Exit

v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.

Pressing does not immediately exit this menu. Select one of the options from this menu or from the legend bar to exit.

Exit & Save Changes

Once you are finished making your selections, choose this option from the Exit menu to ensure the values you selected are saved to the CMOS RAM. An onboard backup battery sustains the CMOS RAM so it stays on even when the PC is turned off. When you select this option, a confirmation window appears. Select YES to save changes and exit.

If you attempt to exit the Setup program without saving your changes, the program prompts you with a message asking if you want to save your changes before exiting. Press to save the changes while exiting.

Exit & Discard Changes

Select this option only if you do not want to save the changes that you made to the Setup program. If you made changes to fields other than System Date, System Time, and Password, the BIOS asks for a confirmation before exiting.

Discard Changes

This option allows you to discard the selections you made and restore the previously saved values. After selecting this option, a confirmation appears. Select YES to discard any changes and load the previously saved values.

Load Setup Defaults

This option allows you to load the default values for each of the parameters on the Setup menus. When you select this option or if you press , a confirmation window appears. Select YES to load default values. Select Exit & Save Changes or make other changes before saving the values to the non-volatile RAM.

5-32 Chapter 5BIOS setup

Exit Options · Load Setup Defaults

Page 105 of the Asus TS500-E5 user manual — Chapter 6
Page 105 · click to enlarge
Page 105

Chapter 6

RAID configuration

This chapter provides instructions for setting up, creating and configuring RAID sets using the available utilities.

Page 106 of the Asus TS500-E5 user manual — 6.1.1 RAID definitions
Page 106 · click to enlarge
Page 106

6.1 Setting up RAID

The motherboard comes with the following RAID solutions:

  • LSI Software RAID Configuration Utility embeded in the Intel ICH9R Southbridge supports Serial ATA hard disk drives and RAID0, RAID1, and RAID10 configurations.
  • Intel Matrix Storage Manager embeded in the Intel ICH9R Southbridge supports Serial ATA hard disk drives and RAID0, RAID1, RAID10, and RAID5 configuration.

6.1.1 RAID definitions

RAID 0 (Data striping) optimizes two identical hard disk drives to read and write data in parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a sustained data transfer rate, double that of a single disk alone, thus improving data access and storage. Use of two new identical hard disk drives is required for this setup.

RAID 1 (Data mirroring) copies and maintains an identical image of data from one drive to a second drive. If one drive fails, the disk array management software directs all applications to the surviving drive as it contains a complete copy of the data in the other drive. This RAID configuration provides data protection and increases fault tolerance to the entire system. Use two new drives or use an existing drive and a new drive for this setup. The new drive must be of the same size or larger than the existing drive.

RAID 10 is data striping and data mirroring combined without parity (redundancy data) having to be calculated and written. With the RAID 10 configuration you get all the benefits of both RAID 0 and RAID 1 configurations. Use four new hard disk drives or use an existing drive and three new drives for this setup.

RAID 5 stripes both data and parity information across three or more hard disk drives. Among the advantages of RAID 5 configuration include better HDD performance, fault tolerance, and higher storage capacity. The RAID 5 configuration is best suited for transaction processing, relational database applications, enterprise resource planning, and other business systems. Use a minimum of three identical hard disk drives for this setup.

Intel® Matrix Storage. The Intel® Matrix Storage technology supported by the ICH9R chip allows you to create a RAID 0, RAID 1, RAID 5, and RAID 10* function to improve both system performance and data safety. You can also combine two RAID sets to get higher performance, capacity, or fault tolerance provided by the difference RAID function. For example, RAID 0 and RAID 1 set can be created by using only two identical hard disk drives.

If you want to boot the system from a hard disk drive included in a created RAID set, copy first the RAID driver from the support CD to a floppy disk before you install an operating system to the selected hard disk drive.

6-2 Chapter 6RAID configuration
Page 107 of the Asus TS500-E5 user manual — 6.1.4 RAID configuration utilities
Page 107 · click to enlarge
Page 107

6.1.2 Installing hard disk drives

The motherboard supports Serial ATA for RAID set configuration. For optimal performance, install identical drives of the same model and capacity when creating a disk array.

To install the SATA hard disks for RAID configuration:

1. Install the SATA hard disks into the drive bays following the instructions in the system user guide.
2. Connect a SATA signal cable to the signal connector at the back of each drive and to the SATA connector on the motherboard.
3. Connect a SATA power cable to the power connector on each drive.

6.1.3 Setting the RAID item in BIOS

You must set the RAID item in the BIOS Setup before you can create a RAID set from SATA hard disk drives attached to the SATA connectors supported by the Intel

® ICH9R Southbridge chip. To do this:

1. Enter the BIOS Setup during POST.
2. Go to the Main Menu > IDE Configuration , then press .
3. Set the SATA#1 Configuration item to [Enhanced].
4. Set the Configure SATA#1 as item to [RAID].
5. Save your changes, then exit the BIOS Setup.

Refer to Chapter 5 for details on entering and navigating through the BIOS Setup.

6.1.4 RAID configuration utilities

Depending on the RAID connectors that you use, you can create a RAID set using the utilities embedded in each RAID controller. For example, use the LSI Software RAID Configuration Utility or the Intel

® Matrix Storage Manager if you installed Serial ATA hard disk drives on the Serial ATA connectors supported by the Intel

® ICH9R Southbridge.

Refer to the succeeding sections for details on how to use each RAID configuration utility.

Page 108 of the Asus TS500-E5 user manual — 6.2 LSI Software RAID Configuration Utility
Page 108 · click to enlarge
Page 108

6.2 LSI Software RAID Configuration Utility

The LSI Software RAID Configuration Utility allows you to create RAID 0, RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard Southbridge chip.

To enter the LSI Software RAID Configuration Utility:

1. Turn on the system after installing all the SATA hard disk drives.
2. During POST, the LSI Software RAID Configuration Utility automatically detects the installed SATA hard disk drives and displays any existing RAID set(s). Press + to enter the utility.

LSI MegaRAID Software RAID BIOS Version A.01 08131852R LSI SATA RAID Found at PCI Bus No: Dev No:1F Device present at Port 0 HDS722512VLSA80 117800MB Device present at Port 1 HDS722512VLSA80 117800MB

Press Ctrl-M or Enter to run LSI Software RAID Setup Utility.

  • The LSI Software RAID Configuration Utitlity auto configures to RAID 1 when the SATA to RAID Mode is enabled.
  • The RAID setup screens shown in this section are for reference only and may not exactly match the items on your screen due to the controller version difference.
  • When you create RAID sets with the LSI Software RAID configuration utility, the boot priority of the SATA optical drive has to be manually adjusted. Otherwise, the system will not boot from the connected SATA ODD.
3. The utility main window appears. Use the arrow keys to select an option from the Management Menu , then press . Refer to the Management Menu descriptions on the next page.

At the bottom of the screen is the legend box. The keys on the legend box allow you to navigate through the setup menu options or execute commands. The keys on the legend box vary according to the menu level.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Management Menu Configure Initialize Objects Rebuild Check Consistency

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

6-4 Chapter 6RAID configuration

Configure VD(s)

Page 109 of the Asus TS500-E5 user manual — Using Easy Configuration
Page 109 · click to enlarge
Page 109

Configure Allows you to create RAID 0, RAID 1 or RAID 10 set using the Easy Configuration or the New Configuration command. This menu also allows you to view, add, or clear RAID configurations or select the boot drive

Initialize Allows you to initialize the logical drives of a created RAID set

Objects Allows you to initialize logical drives or change the logical drive parameters

Rebuild Allows you to rebuild failed drives

Check Consistency Allows you to check the data consistency of the logical drives of a

6.2.1 Creating a RAID 0 or RAID 1 set

The LSI Software RAID Configuration Utility allows you to create a RAID 0 or RAID 1 set using two types of configurations: Easy and New.

In Easy Configuration, the logical drive parameters are set automatically including the size and stripe size (RAID 1 only).

In New Configuration, you manually set the logical drive parameters and assign the set size and stripe size (RAID 1 only).

Using Easy Configuration

To create a RAID set using the Easy Configuration option:

1. From the utility main menu, highlight Configure , then press .
2. Use the arrow keys to select Easy Configuration , then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive

Management Menu Configure Initialize Objects Rebuild Check Consistency

Defines Physical Arrays. An Array Will Automatically Become A VD

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

Menu Description · created RAID set

Page 110 of the Asus TS500-E5 user manual — PORT #
Page 110 · click to enlarge
Page 110
3. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Select the drives you want to include in the RAID set, then press . When selected, the drive indicator changes from READY to ONLIN A[X]-[Y] , where X is the array number, and Y is the drive number.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

PORT #

READY

READY

Port # 0 DISK 77247MB HDS728080PLA380 PF20A60A

The information of the selected hard disk drive displays at the bottom of the screen.

4. Select all the drives required for the RAID set, then press . The configurable array appears on screen.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

PORT #

ONLIN A00-00

ONLIN A00-01

Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A

6-6 Chapter 6RAID configuration

SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP · SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP

Page 111 of the Asus TS500-E5 user manual — 0 1 77247MB 2 64 KB ONLINE
Page 111 · click to enlarge
Page 111
5. Press , select the configurable array, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

PORT #

A-0 SPAN-1

DNLIN A00-00

DNLIN A00-01

Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit

Press again, the logical drive information appears including a Logical Drive menu that allows you to change the logical drive parameters.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

0 1 77247MB 2 64 KB ONLINE

PORT #

DNLIN A00-00

DNLIN A00-01

Logical Drive 0 RAID = 1 Size = 77247MB DWC = Off RA = On Accept SPAN = NO

Choose RAID Level For This VD

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

Select Configurable Array(s)

Page 112 of the Asus TS500-E5 user manual — 6.2.1 Creating a RAID 0 or RAID 1 set
Page 112 · click to enlarge
Page 112
6. Select RAID from the Logical Drive menu, then press .
7. Select the RAID level from the menu, then press .
Asus TS500-E5 — 6.2.1 Creating a RAID 0 or RAID 1 set diagram (page 112)
Fig. 103 · 6.2.1 Creating a RAID 0 or RAID 1 set

You need at least two identical hard disk drives when creating a RAID 1 set.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Logical Drive 0 RAID = 1 Size = 77247MB DWC = Off RA = On Accept SPAN = NO

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

8. When creating a RAID 1 set, select DWC from the Logical Drive menu, then press .

When creating a RAID 0 set, proceed to step 10.

9. Select On to enable the Disk Write Cache setting, then press .
Asus TS500-E5 — 6.2.1 Creating a RAID 0 or RAID 1 set diagram (page 112)
Fig. 104 · 6.2.1 Creating a RAID 0 or RAID 1 set

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Logical Drive 0 RAID = 1 Size = 77247MB DWC = Off RA = On Accept SPAN = NO

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

Enabling DWC can improve the performance, but with the risk of data loss.

6-8 Chapter 6RAID configuration
Page 113 of the Asus TS500-E5 user manual — 0 1 77247MB 2 64 KB ONLINE
Page 113 · click to enlarge
Page 113
10. When finished setting the selected logical drive configuration, select Accept from the menu, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

0 1 77247MB 2 64 KB ONLINE

PORT #

DNLIN A00-00

DNLIN A00-01

Logical Drive 0 RAID = 1 Size = 77247MB DWC = Off RA = On Accept SPAN = NO

Accept This VD Configuration And Go To Next VD

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

11. Follow steps 5 to 10 to configure additional logical drives.
12. When prompted, save the configuration, then press to return to the Management Menu .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive

Save Configuration? Yes No

Management Menu Configure Initialize Objects Rebuild Check Consistency

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

0 1 77247MB 2 64 KB ONLINE

Select Yes Or No

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

Page 114 of the Asus TS500-E5 user manual — 0 1 77247MB 2 64 KB ONLINE
Page 114 · click to enlarge
Page 114

Using New Configuration

When a RAID set is already existing, using the New Configuration command erases the existing RAID configuration data. If you do not want to delete the existing RAID set, use the View/Add Configuration command to view or create another RAID configuration.

To create a RAID set using the New Configuration option:

1. From the utility main menu, highlight Configure , then press .
2. Use the arrow keys to select New Configuration , then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive

Management Menu Configure Initialize Objects Rebuild Check Consistency

Clear Existing Configuration And Start A New Configuration

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

3. Follow steps 3 to 7 of the previous section.
4. Select Size from the Logical Drive menu, then press .
5. Key-in the desired logical drive size, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

0 1 77247MB 2 64 KB ONLINE

PORT #

DNLIN A00-00

DNLIN A00-01

Enter VD Size (MB)77247

Logical Drive 0 RAID = 1 Size = 77247MB DWC = Off RA = On Accept SPAN = NO

Enter VD Size (MB):

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

6. Follow steps 8 to 12 of the previous section to create the RAID set.
6-10 Chapter 6RAID configuration
Page 115 of the Asus TS500-E5 user manual — PORT #
Page 115 · click to enlarge
Page 115

6.2.2 Creating a RAID 10 set

You can create a RAID 10 set using four identical hard disk drives.

To create a RAID 10 set using the Easy Configuration option:

1. From the utility main menu, highlight Configure , then press .
2. Use the arrow keys to select Easy Configuration , then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive

Management Menu Configure Initialize Objects Rebuild Check Consistency

Defines Physical Arrays. An Array Will Automatically Become A VD

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

3. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Select the drive(s) you want to include in the RAID set, then press . When selected, the drive indicator changes from READY to ONLIN A[X]-[Y ], where X is the array number, and Y is the drive number.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

PORT #

READY

READY

READY

READY

Port # 0 DISK 77247MB HDS728080PLA380 PF20A60A

The information of the selected hard disk drive displays at the bottom of the screen.

SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP

Page 116 of the Asus TS500-E5 user manual — PORT #
Page 116 · click to enlarge
Page 116
4. Select all the drives required for the RAID 10 set, then press . The configurable array appears on screen.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

PORT #

ONLIN A00-00

ONLIN A00-01

ONLIN A00-02

ONLIN A00-03

Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A

5. Press , select the configurable array, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

PORT #

A-0 SPAN-1

DNLIN A00-00

DNLIN A00-01

Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit

6-12 Chapter 6RAID configuration

SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP · Select Configurable Array(s)

Page 117 of the Asus TS500-E5 user manual — 6.2.2 Creating a RAID 10 set
Page 117 · click to enlarge
Page 117

Press again, the logical drive information appears including a Logical Drive menu that allows you to change the logical drive parameters.

6. Select RAID from the Logical Drive menu, then press .
7. Select RAID 10 from the menu, then press .
Asus TS500-E5 — 6.2.2 Creating a RAID 10 set diagram (page 117)
Fig. 105 · 6.2.2 Creating a RAID 10 set

You need at least four identical hard disk drives when creating a RAID 10 set.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Logical Drive 0 RAID = 0 Size = 308988MB DWC = Off RA = On Accept SPAN = NO

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

8. Select DWC from the Logical Drive menu, then press .
9. Select On to enable the Disk Write Cache setting, then press .
Asus TS500-E5 — 6.2.2 Creating a RAID 10 set diagram (page 117)
Fig. 106 · 6.2.2 Creating a RAID 10 set

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Logical Drive 0 RAID = 1 Size = 154494MB DWC = Off RA = On Accept SPAN = NO

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

Page 118 of the Asus TS500-E5 user manual — 0 10 308988MB 4 64 KB ONLINE
Page 118 · click to enlarge
Page 118
10. When finished setting the selected logical drive configuration, select Accept from the menu, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

0 10 308988MB 4 64 KB ONLINE

PORT #

DNLIN A00-00

DNLIN A00-01

Logical Drive 0 RAID = 10 Size = 308988MB DWC = Off RA = On Accept SPAN = NO

ONLIN A00-03

Accept This VD Configuration And Go To Next VD

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

11. When prompted, save the configuration, then press to return to the Management Menu .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive

Save Configuration? Yes No

Management Menu Configure Initialize Objects Rebuild Check Consistency

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

0 10 308988MB 4 64 KB ONLINE

Select Yes Or No

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

6-14 Chapter 6RAID configuration
Page 119 of the Asus TS500-E5 user manual — PORT #
Page 119 · click to enlarge
Page 119

6.2.3 Adding or viewing a RAID configuration

You can add a new RAID configuration or view an existing configuration using the View/Add Configuration command.

Adding a new RAID configuration

To add a new RAID configuration:

1. From the Management Menu , highlight Configure , then press .
2. Use the arrow keys to select View/Add Configuration , then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive

Management Menu Configure Initialize Objects Rebuild Check Consistency

View/Add to The Existing Configuration

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

3. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Select the drive(s) you want to include in the RAID set, then press . When selected, the drive indicator changes from READY to ONLIN A[X]-[Y] , where X is the array number, and Y is the drive number.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

PORT #

READY

READY

Port # 0 DISK 77247MB HDS728080PLA380 PF20A60A

The information of the selected hard disk drive displays at the bottom of the screen.

SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP

Page 120 of the Asus TS500-E5 user manual — PORT #
Page 120 · click to enlarge
Page 120
4. Select all the drives required for the RAID set, then press . The configurable array appears on screen.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

PORT #

ONLIN A00-00

ONLIN A00-01

ONLIN A01-00

ONLIN A01-01

Port # 3 DISK 77247MB HDS728080PLA380 PF20A60A

5. Press , select the configurable array, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

View/Add Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

PORT #

A-0 SPAN-1

DNLIN A00-00

DNLIN A00-01

Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Configure Esc-Quit

6. Press again, and select RAID from the Logical Drive menu, then press .
6-16 Chapter 6RAID configuration

SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP · Select Configurable Array(s)

Page 121 of the Asus TS500-E5 user manual — PORT #
Page 121 · click to enlarge
Page 121
7. Select the RAID level from the menu, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Easy Configuration - ARRAY SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

0 0 154494MB 2 64 KB ONLINE 0 1 77247MB 2 64 KB ONLINE

PORT #

DNLIN A00-00

DNLIN A00-01

Logical Drive 1 RAID = 1 Size = 77247MB DWC = Off RA = On Accept SPAN = NO

RAID Level RAID 0 RAID 1

Choose RAID Level For This VD

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

8. Follow steps 8 to 12 of the Creating a RAID set: Using Easy Configuration section.
9. When prompted, save the configuration, then press to return to the Management Menu .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive

Save Configuration? Yes No

Management Menu Configure Initialize Objects Rebuild Check Consistency

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

0 0 154494MB 2 64 KB ONLINE 1 1 77247MB 2 64 KB ONLINE

Select Yes Or No

Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option

10. Follow steps 8 to 13 of the Creating a RAID set: Using Easy Configuration section to add the new RAID configuration.
Page 122 of the Asus TS500-E5 user manual — 0 10 154494MB 4 64 KB ONLINE
Page 122 · click to enlarge
Page 122

6.2.4 Initializing the logical drives

After creating the RAID set(s), you must initialize the logical drives. You may initialize the logical drives of a RAID set(s) using the Initialize or Objects command on the Management Menu.

Using the Initialize command

To initialize the logical drive using the Initialize command:

1. From the Management Menu , highlight Initialize , then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Management Menu Configure Initialize Objects Rebuild Check Consistency

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

2. The screen displays the available RAID set(s) and prompts you to select the logical drive to initialize. Use the arrow keys to select the logical drive from the Logical Drive selection, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Management Menu Configure Initialize Objects Rebuild Check Consistency

0 10 154494MB 4 64 KB ONLINE

Logical Drives Loical Drive 0

6-18 Chapter 6RAID configuration

Initialize Logical Drive(s) · Select VD · SPACE-(De)Select, F10-Check Consistency

Page 123 of the Asus TS500-E5 user manual — 0 10 154494MB 4 64 KB ONLINE
Page 123 · click to enlarge
Page 123
3. When prompted, press the to select Yes from the Initialize? dialog box, then press . You may also press to initialize the drive without confirmation.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Management Menu Configure Initialize Objects Rebuild Check Consistency

0 10 154494MB 4 64 KB ONLINE

Logical Drives Loical Drive 0

Initilize Will Destroy Data On Selected VD(s)

Initializing a logical drive(s) erases all data on the drive.

4. A progress bar appears on screen. If desired, press to abort initialization.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Management Menu Configure Initialize Objects Rebuild Check Consistency

Initialization Of LD Is In Process

0 10 154494MB 4 64 KB ONLINE

LD 0 Initialization. Press Esc to Abort.

¦ 85 % Completed

Logical Drives Loical Drive 0

Initialize? Yes No · SPACE-(De)Select, F10-Check Consistency · SPACE-(De)Select, F10-Initialize

Page 124 of the Asus TS500-E5 user manual — Using the Objects command
Page 124 · click to enlarge
Page 124
5. When initialization is completed, press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Management Menu Configure Initialize Objects Rebuild Check Consistency

Initialization Of LD Is In Process

0 10 154494MB 4 64 KB ONLINE

LD 0 Initialization Complete. Press Esc..

¦ 100 % Completed

Logical Drives Loical Drive 0

Using the Objects command

To initialize the logical drives using the Objects command:

1. From the Management Menu , highlight Objects , then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Management Menu Configure Initialize Objects Rebuild Check Consistency

Configure Objects Like Adapter Parameters

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

6-20 Chapter 6RAID configuration

SPACE-(De)Select, F10-Initialize

Page 125 of the Asus TS500-E5 user manual — 6.2.4 Initializing the logical drives
Page 125 · click to enlarge
Page 125
2. Select Virtual Drive from the Objects sub-menu, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Objects Adapter Virtual Drive Physical Drive

Management Menu Configure Initialize Objects Rebuild Check Consistency

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

3. Select the logical drive to initialize from the Virtual Drives sub‑menu, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Vitual Drive(1) Logical Drive 0

Objects Adapter Virtual Drive Physical Drive

Management Menu Configure Initialize Objects Rebuild Check Consistency

Press ENTER To Select A VD, <DEL> To Delete A VD

4. Select Initialize from the pop-up menu, then press to start initialization.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Vitual Drive(1) Logical Drive 0

Objects Adapter Virtual Drive Physical Drive

Management Menu Configure Initialize Objects Rebuild Check Consistency

Initialze Check Consistency View/Update Parameters

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

Show 4 more labels / short text on this page
Change VD Parameters · Select VD · Vitual Drive(0) · Initilize VD
Page 126 of the Asus TS500-E5 user manual — 6.2.4 Initializing the logical drives
Page 126 · click to enlarge
Page 126
5. When prompted, press the to select Yes from the Initialize? dialog box, then press .
Asus TS500-E5 — 6.2.4 Initializing the logical drives diagram (page 126)
Fig. 107 · 6.2.4 Initializing the logical drives

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

6. A progress bar appears on screen. If desired, press to abort initialization.
Asus TS500-E5 — 6.2.4 Initializing the logical drives diagram (page 126)
Fig. 108 · 6.2.4 Initializing the logical drives

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

7. When initialization is completed, press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Asus TS500-E5 — 6.2.4 Initializing the logical drives diagram (page 126)
Fig. 109 · 6.2.4 Initializing the logical drives

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

6-22 Chapter 6RAID configuration
Page 127 of the Asus TS500-E5 user manual — PORT #
Page 127 · click to enlarge
Page 127

6.2.5 Rebuilding failed drives

You can manually rebuild failed hard disk drives using the Rebuild command in the Management Menu.

To rebuild a failed hard disk drive:

1. From the Management Menu , highlight Rebuild , then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Management Menu Configure Initialize Objects Rebuild Check Consistency

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

2. The PHYSICAL DRIVES SELECTION MENU displays the available drives connected to the SATA ports. Select the drive you want to rebuild, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

REBUILD - PHYSICAL DRIVES SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

PORT #

ONLIN A00-00

FAIL A00-01

Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A

Rebuild PD(s) · SPACE-Sel,ENTER-EndArray,F10-Configure,F2-Drive Info,F3-Logical Drives,F4-HSP

Page 128 of the Asus TS500-E5 user manual — PORT #
Page 128 · click to enlarge
Page 128
3. After selecting the drive to rebuild, press . The indicator for the selected drive now shows RBLD .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

REBUILD - PHYSICAL DRIVES SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

PORT #

ONLIN A00-00

RBLD A00-01

Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A

SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Logical Drives

4. When prompted, press to to rebuild the drive.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

REBUILD - PHYSICAL DRIVES SELECTION MENU

Management Menu Configure Initialize Objects Rebuild Check Consistency

PORT #

ONLIN A00-00

RBLD A00-01

Rebuilding Of Drive Will Take A Few Minutes. Start Rebuilding Drive (Y/N)?

Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A

SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Logical Drives

5. When rebuild is complete, press any key to continue.
6-24 Chapter 6RAID configuration
Page 129 of the Asus TS500-E5 user manual — 0 10 154494MB 4 64 KB ONLINE
Page 129 · click to enlarge
Page 129

6.2.6 Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected logical drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects > Adapter menu.

The Check Consistency command is available only for logical drives included in a RAID 1 set.

Using the Check Consistency

To check data consistency using the Check Consistency command:

1. From the Management Menu , select Check Consistency , then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Management Menu Configure Initialize Objects Rebuild Check Consistency

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

2. The screen displays the available RAID set(s) and prompts you to select the logical drive to check. Press the to select the logical drive from the Logical Drive selection, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Management Menu Configure Initialize Objects Rebuild Check Consistency

0 10 154494MB 4 64 KB ONLINE

Logical Drives Loical Drive 0

CC Of VD(s) · Select VD · SPACE-(De)Select, F10-Check Consistency

Page 130 of the Asus TS500-E5 user manual — 0 10 154494MB 4 64 KB ONLINE
Page 130 · click to enlarge
Page 130
3. When prompted, use the arrow keys to select Yes from the Consistency Check dialog box, then press . You may also press to check the drive consistency.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Management Menu Configure Initialize Objects Rebuild Check Consistency

0 10 154494MB 4 64 KB ONLINE

Consistency Check? Yes No

Logical Drives Loical Drive 0

A progress bar appears on screen.

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Logical Drive(s) Configured LD RAID Size #Stripes StripSz Status

Management Menu Configure Initialize Objects Rebuild Check Consistency

0 10 154494MB 4 64 KB ONLINE

VD 0 Consistency Check. Press Esc to Abort.

¦ 85 % Completed

Logical Drives Loical Drive 0

The Data On The Drives Is Inconsistency. Repair Done!

4. While checking the disk consistency, press to display the following options.
  • Stop - Stops the consistency check. The utility stores the

percentage of disk checked, When you restart checking, it continues from the last percentage completed rather than from zero percent.

  • Continue - Continues the consistency check.
  • Abort - Aborts the consistency check. When you restart checking, it

continues from zero percent.

5. When checking is complete, press any key to continue.
6-26 Chapter 6RAID configuration
Show 4 more labels / short text on this page
Select VD · SPACE-(De)Select, F10-Check Consistency · CC Under Process · SPACE-(De)Select, F10-Check Consistency
Page 131 of the Asus TS500-E5 user manual — Using the Objects command
Page 131 · click to enlarge
Page 131

Using the Objects command

To check data consistency using the Objects command:

1. From the Management Menu , select Objects , then select Logical Drive from the menu.
2. Use the arrow keys to select the logical drive you want to check, then press .
3. Select Check Consistency from the pop-up menu, then press .
4. When prompted, use the arrow keys to select Yes from the dialog box to check the drive.
5. When checking is complete, press any key to continue.
Page 132 of the Asus TS500-E5 user manual — 6.2.7 Deleting a RAID configuration
Page 132 · click to enlarge
Page 132

6.2.7 Deleting a RAID configuration

To delete a RAID configuration:

1. From the Management Menu , select Configure > Clear Configuration , then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive

Management Menu Configure Initialize Objects Rebuild Check Consistency

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

2. When prompted, use the arrow keys to select Yes from the Clear Configuration? dialog box, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive

Management Menu Configure Initialize Objects Rebuild Check Consistency

Clear Configuration? Yes No

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

The utility clears the current array.

3. Press any key to continue.
6-28 Chapter 6RAID configuration

Clear Existing Configuration · Clear Existing Configuration

Page 133 of the Asus TS500-E5 user manual — 6.2.8 Selecting the boot drive from a RAID set
Page 133 · click to enlarge
Page 133

6.2.8 Selecting the boot drive from a RAID set

You must have created a new RAID configuration before you can select the boot drive from a RAID set. Refer to the Creating a RAID set: Using New Configuration section for details.

To select the boot drive from a RAID set:

1. From the Management Menu , select Configure > Select Boot Drive , then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive

Management Menu Configure Initialize Objects Rebuild Check Consistency

Select A Boot VD

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

2. When prompted, use the arrow keys to select the bootable logical drive from the list, then press .

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Bootable VDs(1):Current Boot VD(0) Boot Drive 0

Configuration Menu Easy Configuration New Configuration View/Add Configuration Clear Configuration Select Boot Drive

Management Menu Configure Initialize Objects Rebuild Check Consistency

Select A Boot VD

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

3. The logical drive is selected as boot drive. Press any key to continue.
Page 134 of the Asus TS500-E5 user manual — 6.2.9 Enabling the WriteCache
Page 134 · click to enlarge
Page 134

6.2.9 Enabling the WriteCache

You may enable the RAID controller’s WriteCache option to improve the data transmission performance.

When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives.

To enable WriteCache:

1. From the Management Menu , select Objects > Adapter , then press to display the adapter properties.
2. Select WriteCache , then press to turn the option On (enabled).

LSI Logic Software RAID Configuration Utility Ver A.51 Aug 13, 2007

Adapter 0 Rebuild Rate = 30 Chk Const Rate = 30 FGI Rate = 30 BGI Rate = 30 Disk WC = Off Read Ahead = On Bios State = Enable Stop On Error = No Fast Init = Enable Auto Rebuild = On Auto Resume = Enable Disk Coercion = 1GB Factory Default

Objects Adapter Virtual Drive Physical Drive

Management Menu Configure Initialize Objects Rebuild Check Consistency

Disk Write Cache - Off(Write Through) or On(Write Back)

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

3. When finished, press any key to continue.
6-30 Chapter 6RAID configuration
Page 135 of the Asus TS500-E5 user manual — [ DISK/VOLUME INFORMATION ]
Page 135 · click to enlarge
Page 135

6.3 Intel

® Matrix Storage Manager Option ROM Utility

® Matrix Storage Manager Option ROM utility allows you to create RAID 0, RAID 1, RAID 10, and RAID 5 set(s) from Serial ATA hard disk drives.

To enter the Intel

® Matrix Storage Manager Option ROM Utility:

1. Turn on the system after installing all Serial ATA hard disk drives.
2. During POST, press to display the utility main menu.

Intel(R) Matrix Storage Manager Option ROM v7.6.0.1011 ICH9R wRAID5

Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.

[ MAIN MENU ]

1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID 4. Exit

[ DISK/VOLUME INFORMATION ]

RAID Volumes: None defined.

Physical Disks: Port Drive Model Serial # Size Type/Status(Vol ID) 0 XXXXXXXXXXX XXXXXXXX XX.XXGB Non-RAID Disk 1 XXXXXXXXXXX XXXXXXXX XX.XXGB Non-RAID Disk 2 XXXXXXXXXXX XXXXXXXX XX.XXGB Non-RAID Disk 3 XXXXXXXXXXX XXXXXXXX XX.XXGB Non-RAID Disk

[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu

The navigation keys at the bottom of the screen allow you to move through the menus and select the menu options.

The RAID setup screens shown in this section are for reference only and may not exactly match the items on your screen due to the controller version difference.

The utility supports maxium four hard disk drives for RAID configurration.

The Intel

Page 136 of the Asus TS500-E5 user manual — [ SELECT DISKS ]
Page 136 · click to enlarge
Page 136

6.3.1 Creating a RAID 0 set (Stripe)

To create a RAID 0 set:

1. From the utility main menu, select 1. Create RAID Volume , then press . This screen appears.

Intel(R) Matrix Storage Manager Option ROM v7.6.0.1011 ICH9R wRAID5

Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.

[ CREATE ARRAY MENU ]

NameRAID Level:

Volume0 RAID0(Stripe) Select Disks 128KB 0.0 GB

DisksStrip Size:

Capacity:

[ DISK/VOLUME INFORMATION ]

Enter a string between 1 and 16 characters in length that can be used to uniquely identify the RAID volume. This name is case sensitive and cannot

contain special characters.

[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu

2. Enter a name for the RAID 0 set, then press .
3. Highlight RAID Level , press the up/down arrow key to select RAID 0 (Stripe) , then press .
4. Highlight the Disks item, then press to select the hard disk drives you want to include in the RAID set. The SELECT DISKS screen appears.

[ SELECT DISKS ]

Port Drive Model Serial # Size Status 0 XXXXXX XXXXXX XX.XGB Non-RAID Disk 1 XXXXXX XXXXXX XX.XGB Non-RAID Disk 2 XXXXXX XXXXXX XX.XGB Non-RAID Disk 3 XXXXXX XXXXXX XX.XGB Non-RAID Disk

Select 2 to 4 disks to use in creating the volume.

[↑↓]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete

5. Use the up/down arrow key to highlight a drive, then press to select. A small triangle marks the selected drive. Press after completing your selection.
6-32 Chapter 6RAID configuration

Create Volume

Page 137 of the Asus TS500-E5 user manual — 6.3.1 Creating a RAID 0 set (Stripe)
Page 137 · click to enlarge
Page 137
6. Use the up/down arrow key to select the stripe size for the RAID 0 array, then press . The available stripe size values range from 4 KB to 128 KB. The default stripe size is 128 KB.

A lower stripe size is recommended for server systems. A higher stripe size is recommended for multimedia computer systems used mainly for audio and video editing.

7. Highlight the Capacity item, enter the desired RAID volume capacity, then press . The default value indicates the maximum allowed capacity.
8. When the Create Volume item is highlighted, press . A warning message appears.

Are you sure you want to create this volume? (Y/N):

9. Press to create the RAID volume and return to the main menu, or to go back to the Create Array menu.
Page 138 of the Asus TS500-E5 user manual — [ DISK/VOLUME INFORMATION ]
Page 138 · click to enlarge
Page 138

6.3.2 Creating a RAID 1 set (Mirror)

To create a RAID 1 set:

1. From the utility main menu, select 1. Create RAID Volume , then press . This screen appears.

Intel(R) Matrix Storage Manager Option ROM v7.6.0.1011 ICH9R wRAID5

Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.

[ CREATE ARRAY MENU ]

NameRAID Level:

Volume1 RAID1(Mirror) Select Disks N/A 0.0 GB

DisksStrip Size:

Capacity:

[ DISK/VOLUME INFORMATION ]

Enter a string between 1 and 16 characters in length that can be used to uniquely identify the RAID volume. This name is case sensitive and cannot

contain special characters.

[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu

2. Enter a name for the RAID 1 set, then press .
3. Highlight RAID Level , press the up/down arrow key to select RAID 1 (Mirror) , then press .
4. Follow steps 4 to 5 and 7 to 9 of the previous section to create the RAID 1 set.
6-34 Chapter 6RAID configuration

Create Volume

Page 139 of the Asus TS500-E5 user manual — [ DISK/VOLUME INFORMATION ]
Page 139 · click to enlarge
Page 139

6.3.3 Creating a RAID 10 set (Stripe + Mirror)

To create a RAID 10 set:

1. From the utility main menu, select 1. Create RAID Volume , then press . This screen appears.

Intel(R) Matrix Storage Manager Option ROM v7.6.0.1011 ICH9R wRAID5

Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.

[ CREATE ARRAY MENU ]

NameRAID Level:

Volume1 RAID10(RAID0+1) Select Disks 128KB 0.0 GB

DisksStrip Size:

Capacity:

[ DISK/VOLUME INFORMATION ]

Enter a string between 1 and 16 characters in length that can be used to uniquely identify the RAID volume. This name is case sensitive and cannot

contain special characters.

[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu

2. Enter a name for the RAID 10 set, then press .
3. Highlight RAID Level , press the up/down arrow key to select RAID 10 (RAID0+1) , then press .
4. Follow steps 4 to 9 of section 6.3.1 Creating a RAID 0 set (striped) to create the RAID 10 set.

Create Volume

Page 140 of the Asus TS500-E5 user manual — [ DISK/VOLUME INFORMATION ]
Page 140 · click to enlarge
Page 140

6.3.4 Creating a RAID 5 set (Parity)

To create a RAID 5 set:

1. From the utility main menu, select 1. Create RAID Volume , then press . This screen appears.

Intel(R) Matrix Storage Manager Option ROM v5.6.2.1002 ESB2 wRAID5

Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.

[ CREATE ARRAY MENU ]

NameRAID Level:

Volume1 RAID5(Parity) Select Disks 128KB 0.0 GB

DisksStrip Size:

Capacity:

[ DISK/VOLUME INFORMATION ]

Enter a string between 1 and 16 characters in length that can be used to uniquely identify the RAID volume. This name is case sensitive and cannot

contain special characters.

[↑↓]-Select [ESC]-Exit [ENTER]-Select Menu

2. Enter a name for the RAID 10 set, then press .
3. Highlight RAID Level , press the up/down arrow key to select RAID5 , then press .
4. Follow steps 4 to 9 of section 6.3.1 Creating a RAID 0 set (striped) to create the RAID 5 set.
6-36 Chapter 6RAID configuration

Create Volume

Page 141 of the Asus TS500-E5 user manual — [ DELETE VOLUME VERIFICATION ]
Page 141 · click to enlarge
Page 141

6.3.5 Deleting a RAID set

Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set.

To delete a RAID set:

1. From the utility main menu, select 2. Delete RAID Volume , then press to display this screen.

Intel(R) Matrix Storage Manager Option ROM v7.6.0.1011 ICH9R wRAID5

Copyright(C) 2003-05 Intel Corporation. All Rights Reserved.

[ DELETE VOLUME MENU ]

Name Level Drives Capacity Status Bootable Volume0 RAIDX(xxxxx) X XXX.XGB Normal Yes

[ HELP ]

Deleting a volume will destroy the volume data on the drive(s) and

cause any member disks to become available as non-RAID disks.

NON-RECOVERABLE.

[↑↓]-Select [<ESC>]-Previous Menu [<Del>]-Delete Volume

2. Use the up/down arrow key to select the RAID set you want to delete, then press . This window appears.

[ DELETE VOLUME VERIFICATION ]

ALL DATA IN THE VOLUME WILL BE LOST! Are you sure you want to delete volume “VolumeX”? (Y/N):

3. Press to delete the RAID set and return to the utility main menu; otherwise, press to return to the Delete Volume menu.
Page 142 of the Asus TS500-E5 user manual — [ CONFIRM EXIT ]
Page 142 · click to enlarge
Page 142

6.3.6 Resetting disks to Non-RAID

Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive.

To reset a RAID set hard disk drive:

1. From the utility main menu, select 3. Reset Disks to Non-RAID , then press to display this screen.

[ RESET RAID DATA ]

Resetting RAID data will remove internal RAID structures from the selected RAID disks. By removing these structures, the drive will revert back to a non-RAID disk.

Port Drive Model Serial # Size Status 0 XXXXXXXXXXXX XXXXXXXX XX.XGB Member Disk 1 XXXXXXXXXXXX XXXXXXXX XX.XGB Member Disk Select the disks that should be reset.

[↑↓]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete

2. Use the up/down arrow key to highlight the RAID set drive you want to reset, then press to select.
3. Press to reset the RAID set drive. A confirmation message appears.
4. Press to reset the drive or press to return to the utility main menu.
5. Follow steps 2 to 4 to select and reset other RAID set drives.

6.3.7 Exiting the Intel

® Matrix Storage Manager

To exit the utility:

1. From the utility main menu, select 4. Exit , then press . This window appears.

[ CONFIRM EXIT ]

Are you sure you want to exit? (Y/N):

2. Press to exit or press to return to the utility main menu.
6-38 Chapter 6RAID configuration
Page 143 of the Asus TS500-E5 user manual — Chapter 7
Page 143 · click to enlarge
Page 143

Chapter 7

Driver installation

This chapter provides instructions for installing the necessary drivers for different system components.

Page 144 of the Asus TS500-E5 user manual — 7.1.1 Creating a RAID driver disk
Page 144 · click to enlarge
Page 144

7.1 RAID driver installation

After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides instructions on how to install the RAID controller drivers during OS installation.

7.1.1 Creating a RAID driver disk

You may have to use another system to create the RAID driver disk from the system/motherboard support CD or from the Internet.

If you have created RAID sets with the LSI Software RAID configuration utility, the boot priority of the SATA optical disk drive has to be manually adjusted. Otherwise, the system will not boot from the connected SATA ODD.

A floppy disk with the RAID driver is required when installing Windows

® or Red Hat ® Enterprise operating system on a hard disk drive that is included in a RAID set. You can create a RAID driver disk in DOS (using the Makedisk application in the support CD).

To create a RAID driver disk in DOS environment:

1. Place the motherboard support CD in the optical drive.
2. Restart the computer, then enter the BIOS Setup.
3. Select the optical drive as the first boot priority to boot from the support CD. Save your changes, then exit the BIOS Setup.
4. Restart the computer.
5. Press any key when prompted to boot from CD.

Loading FreeDOS FAT KERNEL GO! Press any key to boot from CDROM...

The Makedisk menu appears.

Create Driver Diskette Menu ICH9R INTEL RAID Driver ICH9R LSI RAID Driver Broadcom ASF Firmware Update FreeDOS command prompt

6. Use the arrow keys to select the type of RAID driver disk you want to ceate and press to enter the sub-menu.
7-2 Chapter 7Driver installation
Page 145 of the Asus TS500-E5 user manual — Broadcom ASF Firmware Update
Page 145 · click to enlarge
Page 145

ICH9R INTEL RAID Driver

ICH9R INTEL RAID Driver Windows 32 bit Windows 64 bit Back Exit

ICH9R LSI RAID Driver

ICH9R LSI RAID Driver Windows Server 2003 32 bit Windows Server 2003 64 bit RHEL AS4 UP5 32/64 bit RHEL AS4 UP6 32/64 bit RHEL 5 UP1 32/64 bit SLES 9 SP4 32 bit SLES 9 SP4 64 bit SLES 10 SP1 32 bit SLES 10 SP2 64 bit Back Exit

Broadcom ASF Firmware Update

Broadcom ASF Firmware Update TS500-E5 system Back Exit

7. Locate the RAID driver and place a blank, high-density floppy disk to the floppy disk drive.
8. Press .
9. Follow screen instructions to create the driver disk.
Page 146 of the Asus TS500-E5 user manual — 7.1 RAID driver installation
Page 146 · click to enlarge
Page 146

To create a RAID driver disk in Windows® Server environment:

1. Restart the system from the hard disk drive, then place the system/ motherboard support CD in the optical drive.
2. Browse the contents of the support CD to locate the driver disk utility. The Windows 32-bit OS RAID driver disk for the Intel ® Matrix Storage Manager is located in:

\Drivers\ICH9R Intel RAID\Driver\makedisk\win32\f6flpy32.exe

The Windows 64-bit OS RAID driver disk for the Intel® Matrix Storage Manager is located in:

\Drivers\ICH9R Intel RAID\Driver\makedisk\win64\f6flpy64.exe

3. Insert a formatted high-density floppy disk to the floppy disk drive.
4. Follow screen instructions to complete the process.
5. After creating a RAID driver disk, eject the floppy disk, then write‑protect it to prevent computer virus infection.

To create a RAID driver disk in Red Hat® Enterprise Linux server environment:

1. Insert a blank formatted high-density floppy disk to the floppy disk drive.
2. Decompress the file into the floppy disk from the following path in the support CD:

For LSI Logic Embedded SATA RAID Driver:

\Drivers\Intel LSI RAID\Driver\makedisk

3. Eject the floppy disk.
7-4 Chapter 7Driver installation
Page 147 of the Asus TS500-E5 user manual — Windows
Page 147 · click to enlarge
Page 147

7.1.2 Installing the RAID controller driver

Windows

® Server OS

® Server OS installation

To install the RAID controller driver when installing Windows

® Server OS:

1. Boot the computer using the Windows

® Server OS Setup starts.

® Server installation CD. The Windows

Press F6 if you need to install a third party SCSI or RAID driver...

2. Press when the message “Press F6 if you need to install a third party SCSI or RAID driver...” appears at the bottom of the screen.
3. When prompted, press to specify an additional device.

Setup could not determine the type of one or more mass storage devices installed in your system, or you have chosen to manually specify an adapter. Currently, Setup will load support for the following mass storage devices(s):

* To specify additional SCSI adapters, CD-ROM drives, or special disk controllers for use with Windows, including those for which you have a device support disk from a mass storage device manufacturer, press S.

* If you do not have any device support disks from a mass storage device manufacturer, or do not want to specify additional mass storage devices for use with Windows, press ENTER.

S=Specify Additional Device ENTER=Continue F3=Exit

Show 4 more labels / short text on this page
During Windows · Windows Setup · Windows Setup · <none>
Page 148 of the Asus TS500-E5 user manual — To an existing Windows
Page 148 · click to enlarge
Page 148
4. Insert the RAID driver disk you created earlier to the floppy disk drive, then press .

Please insert the disk labeled

Manufacturer-supplied hardware support disk

into Drive A:

* Press ENTER when ready.

5. Select the RAID controller driver you need from the list, then press .
6. The Windows

® Setup loads the RAID controller drivers from the RAID driver disk. When prompted, press to continue installation.

7. Setup then proceeds with the OS installation. Follow screen instructions to continue.

To an existing Windows

® Server OS

To install the RAID controller driver on an existing Windows

® Server OS:

1. Restart the computer, then log in with Administrator privileges.

® automatically detects the RAID controller and displays a New Hardware Found window. Click Cancel.

2. Windows
3. Right-click the My Computer icon on the Windows

® desktop , then select Properties from the menu.

4. Click the Hardware tab, then click the Device Manager button to display the list of devices installed in the system.
Asus TS500-E5 — To an existing Windows diagram (page 148)
Fig. 110 · To an existing Windows
7-6 Chapter 7Driver installation

Windows Setup · ENTER=Continue ESC=Cancel F3=Exit

Page 149 of the Asus TS500-E5 user manual — 7.1.2 Installing the RAID controller driver
Page 149 · click to enlarge
Page 149
5. Right-click the RAID controller item, then select Properties .
6. Click the Driver tab, then click the Update Driver button.
7. The Upgrade Device Driver Wizard window appears. Click Next .
8. Insert the RAID driver disk you created earlier to the floppy disk drive.
9. Select the option Search for a suitable driver for my device (recommended) , then click Next .
10. The wizard searches the RAID controller drivers. When found, click Next to install the drivers.
Asus TS500-E5 — 7.1.2 Installing the RAID controller driver diagram (page 149)
Fig. 111 · 7.1.2 Installing the RAID controller driver
11. Click Finish after the driver installation is done.

To verify the RAID controller driver installation:

1. Right-click the My Computer icon on the Windows

® desktop , then select Properties from the menu.

2. Click the Hardware tab, then click the Device Manager button.
3. Click the “+” sign before the item SCSI and RAID controllers , then the LSI Adapter, SAS 3000 series, 8-port with 1068-StorPort item should appear.
Asus TS500-E5 — 7.1.2 Installing the RAID controller driver diagram (page 149)
Fig. 112 · 7.1.2 Installing the RAID controller driver

The screen differs based on the controller.

Page 150 of the Asus TS500-E5 user manual — Red Hat
Page 150 · click to enlarge
Page 150
4. Right-click the RAID controller driver item, then select Properties from the menu.
5. Click the Driver tab, then click the Driver Details button to display the RAID controller drivers.
6. Click OK when finished.

Red Hat

® Enterprise

To install the Intel

® ICH9R LSI Logic Embedded SATA RAID controller driver when installing Red Hat

® Enterprise OS:

1. Boot the system from the Red Hat

® Installation CD.

Asus TS500-E5 — Red Hat diagram (page 150)
Fig. 113 · Red Hat
2. At the boot: , type linux dd , then press .
Asus TS500-E5 — Red Hat diagram (page 150)
Fig. 114 · Red Hat

When installing a Red Hat 2.4 kernel with a Driver Update Disk (DUD) to a disk drive attached to a LSI HBA, use the command below at the install prompt: linux dd updates.

7-8 Chapter 7Driver installation
Page 151 of the Asus TS500-E5 user manual — 7.1.2 Installing the RAID controller driver
Page 151 · click to enlarge
Page 151
3. Select Yes using the key when asked if you have the driver disk. Press
Asus TS500-E5 — 7.1.2 Installing the RAID controller driver diagram (page 151)
Fig. 115 · 7.1.2 Installing the RAID controller driver
4. Select fd0 using the key when asked to select the driver disk source. Press to move the cursor to OK , then press .
Asus TS500-E5 — 7.1.2 Installing the RAID controller driver diagram (page 151)
Fig. 116 · 7.1.2 Installing the RAID controller driver
Page 152 of the Asus TS500-E5 user manual — 7.1.2 Installing the RAID controller driver
Page 152 · click to enlarge
Page 152
5. When prompted, insert the Red Hat

® Enterprise RAID driver disk to the floppy disk drive, select OK, then press .

Asus TS500-E5 — 7.1.2 Installing the RAID controller driver diagram (page 152)
Fig. 117 · 7.1.2 Installing the RAID controller driver

The drivers for the RAID controller are installed to the system.

6. Follow screen instructions to continue the OS installation.
7-10 Chapter 7Driver installation
Page 153 of the Asus TS500-E5 user manual — SuSE Linux
Page 153 · click to enlarge
Page 153

SuSE Linux

To install the RAID controller driver when installing SuSE Linux OS:

1. Boot the system from the SuSE Installation CD.
2. Select Installation from the Boot Options menu, then press .
Asus TS500-E5 — SuSE Linux diagram (page 153)
Fig. 118 · SuSE Linux
3. A message instructs you to prepare the RAID driver disk. Press .
Asus TS500-E5 — SuSE Linux diagram (page 153)
Fig. 119 · SuSE Linux
Page 154 of the Asus TS500-E5 user manual — 7.1.2 Installing the RAID controller driver
Page 154 · click to enlarge
Page 154
4. When prompted, insert the RAID driver disk to the floppy disk drive, then press .
Asus TS500-E5 — 7.1.2 Installing the RAID controller driver diagram (page 154)
Fig. 120 · 7.1.2 Installing the RAID controller driver
5. When prompted, select the floppy disk drive (fd0) as the driver update medium, select OK , then press .
Asus TS500-E5 — 7.1.2 Installing the RAID controller driver diagram (page 154)
Fig. 121 · 7.1.2 Installing the RAID controller driver

The drivers for the RAID controller are installed to the system.

7-12 Chapter 7Driver installation
Page 155 of the Asus TS500-E5 user manual — 7.2 Intel
Page 155 · click to enlarge
Page 155

7.2 Intel

® chipset device installation

This section provides instructions on how to install the Plug and Play components for the Intel

® chipset on the system.

You need to manually install the Intel

® chipset software on a Windows Server operating system. To install the Intel

® chipset device software:

1. Restart the computer, then log on with Administrator privileges.
2. Insert the motherboard/system support CD to the optical drive. The support CD automatically displays the Drivers menu if Autorun is enabled in your computer.
3. Click the item Intel(R) Chipset Device Installation Utility from the menu.
Asus TS500-E5 — 7.2 Intel diagram (page 155)
Fig. 122 · 7.2 Intel
Page 156 of the Asus TS500-E5 user manual — 7.2 Intel® chipset device installation
Page 156 · click to enlarge
Page 156
4. The Intel(R) Chipset Device Software window appears. Click Next to start installation.
Asus TS500-E5 — 7.2 Intel® chipset device installation diagram (page 156)
Fig. 123 · 7.2 Intel® chipset device installation
5. Select Yes to accept the terms of the License Agreement and continue the process.
Asus TS500-E5 — 7.2 Intel® chipset device installation diagram (page 156)
Fig. 124 · 7.2 Intel® chipset device installation
7-14 Chapter 7Driver installation
Page 157 of the Asus TS500-E5 user manual — 7.2 Intel® chipset device installation
Page 157 · click to enlarge
Page 157
6. Read the Readme File Information and press Next to continue the installation.
Asus TS500-E5 — 7.2 Intel® chipset device installation diagram (page 157)
Fig. 125 · 7.2 Intel® chipset device installation
7. After completing the installation, click Finish to complete the setup process.
Asus TS500-E5 — 7.2 Intel® chipset device installation diagram (page 157)
Fig. 126 · 7.2 Intel® chipset device installation
Page 158 of the Asus TS500-E5 user manual — 7.3 LAN driver installation
Page 158 · click to enlarge
Page 158

7.3 LAN driver installation

This section provides instructions on how to install the Broadcom

® Gigabit LAN controller drivers on a Windows

® Server OS.

To install the LAN controller drivers:

1. Restart the computer, then log on with Administrator privileges.
2. Insert the motherboard/system support CD to the optical drive. The CD automatically displays the Drivers menu if Autorun is enabled in your computer.
  • Windows

® automatically detects the LAN controllers and displays a New Hardware Found window. Click Cancel to close this window.

  • If Autorun is NOT enabled in your computer, browse the contents of the support CD to locate the file ASSETUP.EXE from the BIN folder. Doubleclick the ASSETUP.EXE to run the CD.
3. Click the Broadcom 5721 Driver to begin installation.
7-16 Chapter 7Driver installation
Page 159 of the Asus TS500-E5 user manual — 7.3 LAN driver installation
Page 159 · click to enlarge
Page 159
4. Click Next when the InstallShield Wizard window appears.
Asus TS500-E5 — 7.3 LAN driver installation diagram (page 159)
Fig. 127 · 7.3 LAN driver installation
5. Toggle I accept the terms in the license agreement and click Next to continue.
Asus TS500-E5 — 7.3 LAN driver installation diagram (page 159)
Fig. 128 · 7.3 LAN driver installation
Page 160 of the Asus TS500-E5 user manual — 7.3 LAN driver installation
Page 160 · click to enlarge
Page 160
6. Click Install to start the installation.
Asus TS500-E5 — 7.3 LAN driver installation diagram (page 160)
Fig. 129 · 7.3 LAN driver installation
7. Click Finish to exit the wizard when the installation is completed.
Asus TS500-E5 — 7.3 LAN driver installation diagram (page 160)
Fig. 130 · 7.3 LAN driver installation
7-18 Chapter 7Driver installation
Page 161 of the Asus TS500-E5 user manual — 7.4.1 Windows
Page 161 · click to enlarge
Page 161

7.4 VGA driver installation

This section provides instructions on how to install the XGI Volari Z9s Video Graphics Adapter (VGA) driver.

7.4.1 Windows

® Server

You need to manually install the XGI Volari Z9s VGA driver on a Windows® Server operating system. To install the XGI Volari Z9s VGA driver:

1. Restart the computer, then log on with Administrator privileges.
2. Insert the motherboard/system support CD to the optical drive. The support CD automatically displays the Drivers menu if Autorun is enabled in your computer.

The Drivers menu if Autorun is enabled in your computer.

3. The XGI VGA Package window appears, preparing the setup.
Asus TS500-E5 — 7.4.1 Windows diagram (page 161)
Fig. 131 · 7.4.1 Windows
Page 162 of the Asus TS500-E5 user manual — 7.4 VGA driver installation
Page 162 · click to enlarge
Page 162
4. Click Next to start the installation.
Asus TS500-E5 — 7.4 VGA driver installation diagram (page 162)
Fig. 132 · 7.4 VGA driver installation
5. The system will update the VGA driver.
6. When the installation completes, click Finish to restart your computer before using the program.
Asus TS500-E5 — 7.4 VGA driver installation diagram (page 162)
Fig. 133 · 7.4 VGA driver installation
7-20 Chapter 7Driver installation
Page 163 of the Asus TS500-E5 user manual — 7.5.2 Drivers menu
Page 163 · click to enlarge
Page 163

7.5 Management applications and utilities installation

The support CD that came with the motherboard package contains the drivers, management applications, and utilities that you can install to avail all motherboard features.

The contents of the support CD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for updates.

7.5.1 Running the support CD

Place the support CD to the optical drive. The CD automatically displays the Drivers menu if Autorun is enabled in your computer.

If Autorun is NOT enabled in your computer, browse the contents of the support CD to locate the file ASSETUP.EXE from the BIN folder. Double-click the ASSETUP.EXE to run the CD.

7.5.2 Drivers menu

The Drivers menu shows the available device drivers if the system detects installed devices. Install the necessary drivers to activate the devices.

The screen display and driver options vary under different operating system versions.

Page 164 of the Asus TS500-E5 user manual — 7.5.5 Contact information
Page 164 · click to enlarge
Page 164

7.5.3 Management Software menu

The Management Software menu displays the available network and server monitoring applications. Click an item to install.

Asus TS500-E5 — 7.5.3 Management Software menu diagram (page 164)
Fig. 134 · 7.5.3 Management Software menu

7.5.4 Utilities menu

The Utilities menu displays the software applications and utilities that the motherboard supports. Click an item to install.

Asus TS500-E5 — 7.5.4 Utilities menu diagram (page 164)
Fig. 135 · 7.5.4 Utilities menu

7.5.5 Contact information

Click the Contact tab to display the ASUS contact information. You can also find this information on the inside front cover of this user guide.

Asus TS500-E5 — 7.5.5 Contact information diagram (page 164)
Fig. 136 · 7.5.5 Contact information
7-22 Chapter 7Driver installation
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Asus TS500-E5

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Asus TS500-E5

Be the first to ask — other owners or our team will answer.

Original document

Asus TS500-E5 manual PDF

164 pages·6.8 MB·Personal Computer·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…