Panasonic Network Adaptor

8 pages·745 KB·Network Card·PDF·ENDEFRITNLJA
Panasonic Network Adaptor
Table of Contents 80 sections 48 mm · Matsushita Programmable Controller FP-e · 01/2004 · Timer · … ShowHide
Page 1 of the Panasonic Network Adaptor user manual — 01/2004
Page 1 · click to enlarge
Page 1

48 mm

Matsushita Programmable Controller FP-e

Clearwater Tech - Phone800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@ clrwtr.com

01/2004

Page 2 of the Panasonic Network Adaptor user manual — Same programming tools used as with the FP Series
Page 2 · click to enlarge
Page 2
Panasonic Network Adaptor — Timer diagram (page 2)
Fig. 1 · Timer

Do this, do that, do everything.

Timer

Temperature controller

Time switch Hour meter

Programmable

controller

Counter

  • 3-color Display
  • Matches FP0 intelligence (equivalent to FP0-C14)
  • Compact

Simple characters and numerical values can be displayed. Simple messages as well as timer/counter settings and elapsed values can also be displayed.

Panel mountable, little space is taken up on the control panel. The size is only 48 × 48 × 70 mm (behind faceplate).

  • Panel mounted type (in accordance with IP66, IEC standard) To match panel design, a black faceplate is available.
  • Built-in operation switch

Setting values can be changed. The operation switch can also be used as an input.

Same programming tools used as with the FP Series

One programming software for all PLC types

Programming software and cables are common for all FP Series PLCs, so that any program created for the FP Series can be used by the FP-e as well. FPWIN Pro Ver.5 and FPWIN GR from Ver.2.3 offer a dialog to configure the screen display of the FP-e easily. You can check the result of the configuration directly with the display in the dialog.

Clearwater Tech - Phone800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@ clrwtr.com 01/2004
Page 3 of the Panasonic Network Adaptor user manual — Y1
Page 3 · click to enlarge
Page 3
Panasonic Network Adaptor — Optimised for a wide range of applications FP-e Series diagram (page 3)
Fig. 2 · Optimised for a wide range of applications FP-e Seri…

Optimised for a wide range of applications FP-e Series

Equipped with RS485 and RS232C interfaces

  • Up to 99 computer link stations are possible with RS485. (RS485 type) Up to 32 computer link stations are possible using a C-NET adaptor and up to 99 are possible using a commercially available adaptor. You can easily monitor operation status or perform control.
  • With RS232C, communication with up to two ports is possible. (RS232C type)

Computer link

Device, etc.

COM

FLA

POWER

ERROR

CF

FP-e FP-e FP-e RS232C

COM

RDY

ERR

REN

STR

READY

TOOL

COM.2

COM.1

D3

D4

D2

OVF D1

KEYPAD

D6

D7

D8

D5

COM.1

CAMERA1

RS232C RS232C

FCT1

COM

STA

COM

COM.2

Tool port COM. port

FCT2

IN2

ACK

TYP IN1

CAMERA2 MONITOR

IN4

IN7

IN3

IN5 IN6

IN8

RS485

Can even handle temperature control

  • Two-point K-type thermocouple (-30 to 300 ° C) connection is possible. (equipped with thermocouple input) Can be used in place of a temperature controller or used to control them.
  • PID instruction function High-performance temperature control can be achieved with PID instruction.

As temperature

Y0

controller

As a controller for

A0

PV

OUT1

PV

OUT1

temperature

SV

OUT2

SV

OUT2

SV1 SV2 AT

TX/RX

EVT

A1

SV1 SV2 AT

TX/RX

EVT

A1

controller

OFF MODE

OUT

OFF MODE

OUT

KT4

KT4

Up to 32 controllers

RS485

∗Compatible with MODBUS, it can be used as a slave.

Equipped with high-speed counter for support of 2-axis independent positioning

  • Pulse output function The unit comes equipped with 2 channels for pulse output of up to 10 kHz pulses. Since these two channels can be separately controlled, the FP-e is also suitable for 2-axis independent positioning.
  • High-speed counter function In single phase, the 4-channel total is 10 kHz, and in 2phase the 2-channel total is 2 kHz total speed, making the FP-e suitable for inverter control, etc.

(One half for the type with thermocouple input.)

Y0

Y2

Stepping motor Servo motor

START/STOP

Cutter blade control signal

Y1

Y3

Input encoder output into the high-speed counter

Clearwater Tech - Phone800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@ clrwtr.com 01/2004
Show 27 more labels / short text on this page
Personal Computer · Personal Computer · Image Processing · FP-e · Commercially available adaptor · - + · FP-e · PID instruction · Heater · Temperature controller, etc · Temperature controller, etc · FP-e · Thermocouple input · Feeder roller · Cutter · Pulse output · Motor driver 1 · Lead wire · CW/CCW output · and tape · Motor · Inverter · Encoder · signal · Pulse output · Motor driver 2 · CW/CCW output
Page 4 of the Panasonic Network Adaptor user manual — MODE
Page 4 · click to enlarge
Page 4
Panasonic Network Adaptor — RS232C diagram (page 4)
Fig. 3

FP-e Control Unit New Age, Advanced Controller! Timer, Counter, Hour Meter, Temperature Controller and PLC in one Unit

  • Features
1. 5-character, 2-line, 3-color Display Simple characters and numerical values can be displayed. Simple error messages as well as operation instructions and timer/counter set values can be displayed.
2. Front Operation Switch Timer/Counter set values can be changed using front operation switches. The switches can also be used as input switches (X30 to X3F), so you need not install external switches.
3. Equivalent to FP0-C14 Intelligence of Small PLCs In addition to the functions of programmable controller FP0, pulse output and high-speed counter functions can be used. The unit comes equipped with a tool port, and COM. port (RS232C/RS485) for communication.
4. Easy Programming Using Wizard Screen display instructions can be easily created using a programming tool wizard in FPWIN GR Ver. 2.3. or FPWIN Pro Ver. 5.0.
  • Type
5. Smooth Debugging Monitoring memory area data and the I/O status facilitates debugging using the R (register) and I (I/O monitor) display modes.

Type Product No. Calendar

COM.

RS232C

AFPE224300

Calendar timer type (RS232C)

RS232C

AFPE224305

6. Panel Mounted Type The front of a unit is water-proof (in accordance with IP66, IEC standard).

Thermocouple input type (RS232C)

RS232C

AFPE214325

RS485

AFPE224302

Thermocouple input type (RS485)

RS485

AFPE214322

  • Display modes and functions

4 3 1 2 N mode (Normal mode)

S mode (Switch mode)

R mode (Register mode)

I mode (I/O monitor mode)

N

S

PV R

PROG.

PROG.

PROG.

PROG.

MODE

MODE

MODE

MODE

1/2/SET 5

1/2/SET 5

1/2/SET 5

1/2/SET 5

Displays characters and numerical values, numerical data can be changed.

Can also display characters and numerical values. Operation switches can be used as inputs.

Operation memory in the controller can be monitored and its data changed.

I/O status (X, Y) in the controller can be monitored.

Clearwater Tech - Phone800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@ clrwtr.com 01/2004
Show 22 more labels / short text on this page
Thermocouple · Name · timer · input · port · Standard type (RS232C) · Not available · Not available · Available · Not available · FP-e control unit · Available · Available · Standard type (RS485) · Not available · Not available · Not available · Available · FP-e · FP-e · FP-e · FP-e
Page 5 of the Panasonic Network Adaptor user manual — RS232C RS485 RS232C RS232C RS485
Page 5 · click to enlarge
Page 5
Panasonic Network Adaptor — RS232C diagram (page 5)
Fig. 4
  • Performance specifications

AFPE224305 Calendar timer type

(RS232C)

(RS485)

(RS232C)

Programming method/Control method Number of controllable I/O points Program memory Program capacity

Relay symbol/Cyclic operation 14 points [Input: 8, Output: 6 (Tr. NPN: 5/Ry: 1)] 8 points Built-in EEP-ROM 2,720 steps 83 117 0.9 µs/step (Basic instruction) Typical 2 ms 1,008 points (R0 to R62F) 64 points (R9000 to R903F)

12 points [Input6, Output: 6 (Tr. NPN: 5/Ry: 1)] Control unit Front switch input Built-in memory

Operation speed I/O update and Base time

Internal relay (R) Special internal relay (R)

Memory backup Note 7) Special functions Operation memory

144 points (Initial setting: 100 timer points, T0 to T99/44 counter points, C100 to C143 Note 1) Timer range (1 ms, 10 ms, 100 ms, 1 s): selected by instruction 1,660 words (DT0 to DT1659) 112 words (DT9000 to DT9111) 2 points Unlimited number of points 32 points 64 labels 128 stages 16 subroutines 7 programs (external: 6, internal 1) Watchdog timer, program syntax check, etc.

Data register (DT) Special data register (DT) Index registers (IX. IY) Differential points Master control relay points (MCR) Number of labels (JP and LOOP) Number of step ladders Number of subroutines Number of interrupt programs Self-diagnostic function

Available (year, month, day, hour, minute, second and day of week). However, this can only be used when a battery has been installed. 220 days or more (actual usage value: approx. 870 days (25°C). (Periodic replacement interval: 1 year). (Value applies when no power is supplied at all.)

Clock/calendar function Note 2)

Pulse catch input Interrupt input COM. port Note 3)

6 points in total (X0 and X1: 50 µs, X2 to X5: 100 µs)

RS232C RS485 RS232C RS232C RS485

Periodical interrupt Constant scan Password

0.5 ms to 30 s Available Available Counter mode: Addition/subtraction (1-phase) Note 4) - Input points: 4 ch. (Max.) - Max. speed: 10 kHz (total of 4 ch.) - Input contact: X0: count input (ch. 0), X1: count input (ch. 1), X2: reset input Note 5) X3: count input (ch. 2), X4: count input (ch. 3), X5: reset input Note 5)

: 5 kHz (total of 4ch.)

- Min. input pulse width: X0 and X1: 50 µs (10 kHz) X3 and X4: 100 µs (5kHz) Counter mode: 2-phase/individual/direction decision (2-phase) - Input points: 2 ch (Max.) - Max. speed: 2 kHz (total of 2 ch.) - Input contact: X0: count input (ch. 0), X1: count input (ch. 0), X2: reset input X3: count input (ch. 2), X4: count input (ch. 2), X5: reset input - Min. input pulse width: X0 and X1: 50 µs (10 kHz) X3 and X4: 100 µs (5 kHz)

X0 and X1100 µs (5 kHz)

* The combinations 1-phase × 2 ch. and 2-phase × 1 ch. are also possible for the high-speed counter.

: 1 kHz (total of 2ch.)

X0 and X1100 µs (5 kHz)

2 independent points (Y0 and Y1) (No interpolation function)

Pulse output function 40 Hz to 10 kHz (Y0/Y1: 1-point) Note 6) 40 Hz to 5 kHz (Y0/Y1: 2-point)

40 Hz to 5 kHz (1-point) 40 Hz to 2.5 kHz (2-point) 2 points (Y0 and Y1) Frequency: 0. 15 Hz to 1 kHz Duty: 0.1 % to 99.9 % Non-hold type: (all points) From set value to C139 4 points (elapsed values) C140 to C143 976 points (R0 to R60F) 61 words (WR0 to WR60) 32 points (R610 to R62F) 2 words (WR61 to WR62) 1,652 words (DT0 to DT1651) 8 words (DT1652 to DT1659)

Output points Output frequency Timer Counter Counter

Non-hold type Hold type Non-hold type Hold type Non-hold type Hold type

The proportion of timer points to counter points can be changed using a system register. Precision of calendar timer: - At 0°C/32°F, less than 200 seconds of error per month - At 25°C/77°F, less than 70 seconds of error per month - At 55°C/131°F, less than 240 seconds of error per month When using the COM. port for communication, retransmission is recommended. The RS232C driver IC for the COM. port conforms completely to EIA/TIA-232E and CCITT V. 28 standards The max. counting speed (10 kHz) is the counting speed with a rated input voltage of 24 V DC and an ambient temperature of 25°C. The counting speed (frequency) will decrease depending on the voltage and temperature.

If the unit is equipped with both reset inputs X0 and X1, X2 serves as the reset input for X1. If X3 and X4 are used, X5 serves as the reset input for X4. When the positioning control instruction “F168” is performed, the maximum output frequency is 9.5 kHz. The program, system registers and the hold type area (internal relay, data register, and timer/counter) are backed up by the built-in EEP-ROM. When a battery is replaced with a new one in the FP-e unit with a calendar timer function, settings can be changed without installing a battery. The data cannot be stored even when the settings are changed using the system register. F180 (SCR) and F181 (DSP) instructions are supported from Control FPWIN GR Ver. 2.2. and FPWIN Pro V 4.1.

Clearwater Tech - Phone800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@ clrwtr.com 01/2004
Show 25 more labels / short text on this page
Model · AFPE224300 Standard type · AFPE224302 Standard type · AFPE214325 Thermocouple input · AFPE214322 Thermocouple input · Item · type (RS232C) · type (RS485) · Basic High-level · Number of instruction · areas Relays · points · Timer/Counter (T/C) · Memory · Not available · Not available · Battery life · Not available · Not available · High-speed counter function · Output points · Output frequency · PWM output function · Internal relay · Data register
Page 6 of the Panasonic Network Adaptor user manual — 0.1°C
Page 6 · click to enlarge
Page 6
Panasonic Network Adaptor — RS232C diagram (page 6)
Fig. 5
  • General specifications

24 V DC

21.6 to 26.4 V DC

Allowed momentary power off time

30 to 85%RH (non-condensing)

30 to 85%RH (non-condensing)

Input terminals (COM, X0 to Xn) Output terminals (Y0 to Y4)

Power supply terminal, Function earth Input terminal (A0, A1) COM. (RS232C) terminal

500 V AC for 1 minute

Output terminal (Y5) Power supply terminal, Function earth Input terminal (COM, X0 to Xn, A0, A1) COM. (RS232C) terminal

1500 V AC for 1 minute

Input terminals (COM, X0 to Xn) Output terminals (Y0 to Y4) 500 V AC for 1 minute

Input terminals (COM, X0 to Xn) Output terminals (Y0 to Y5)

Power supply terminal, Function earth Input terminal (A0, A1) COM. (RS232C) terminal

Min. 100 M (measured with 500 V DC)

Input terminals (COM, X0 to Xn) Output terminals (Y0 to Y5)

Vibration resistance 10 to 55 Hz, 1 cycle/min. Double amplitude: 0.75 mm, 10 min. on X, Y, and Z axes

98 m/s2 or more, 4 times on X, Y, and Z axes

1000V (p-p) with pulse widths 50 ns and 1 µs (based on in-house measurements)

Free from corrosive gases and excessive dust

200 mA or less (24 V DC)

IP66-compliant front section (Only when a rubber packing is used.)

Approx. 130 g

  • DC input specifications (X0 to X7)
  • Thermocouple input specifications

8 points (6 points for thermocouple input type)

2 points (CH0WX1, CH1: WX2)

24 V DC

–30.0 to 300.0°C ∗1) (–22 to 572°F)

21.6 to 26.4 V DC

±0.5%FS±1.5°C (FS = –30 to 300°C)

Approx. 4.3 mA

0.1°C

8 points/common (6 points/common for thermocouple input type) Either the positive or negative of the input power supply can be connected to common terminal.

250 ms/2CH ∗2)

Input points per common

Between internal circuit and thermocouple input circuit: noninsulated ∗3)

Between CH0 and CH1 of thermocouple input: PhotoMOS insulation

19.2 V or less/4 mA or less

2.4 V or more/1 mA or more

Detection function of wire disconnection Available

Input impedance Approx. 5.1 k (X0, X1) Approx. 5.6 k (X2 to X7)

∗1) Temperature can be measured up to 330°C (626°F). When the measured temperature

50 µs or less (X0, X1) Note 1)

exceeds 330°C (626°F) or the thermocouple wiring is disconnected, “K20000” is written to the register. ∗2) Temperature conversion for thermocouple input is performed every 250 ms. The

100 µs or less (X2 to X5) Note 1)

conversion data is updated on the internal data register after the scan is completed. ∗3) The internal circuit and thermocouple input circuit are not insulated. Therefore, use the

2 ms or less (X6, X7)

nongrounding type thermocouples and sheath tubes.

50 µs or less (X0, X1) Note 1)

100 µs or less (X2 to X5) Note 1)

2 ms or less (X6, X7)

LCD display (I/O monitor mode)

Clearwater Tech - Phone800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@ clrwtr.com 01/2004
Show 43 more labels / short text on this page
Item · Description · Rated voltage · Operating voltage range · 10 ms · Ambient temperature · 0 to +55°C · Storage temperature · –20 to +70°C · Ambient humidity · Storage humidity · Breakdown voltage · Insulation resistance · Shock resistance · Noise resistance · Operating condition · Current consumption · Protection · Mass · Item · Description · Item · Description · Number of input · Number of input · Insulation method · Optical coupler · Temperature sensor type · Thermocouple type K · Rated input voltage · Input range · Operating voltage range · Accuracy · Rated input current · Resolution · Conversion time · Insulation method · ON voltage/ON current · OFF voltage/OFF current · OFF to ON · Response time · ON to OFF · Operating mode indicator
Page 7 of the Panasonic Network Adaptor user manual — COM
Page 7 · click to enlarge
Page 7
Panasonic Network Adaptor — RS232C diagram (page 7)
Fig. 6
  • Transistor NPN output specifications
  • Relay output specifications

(For Y0 to Y4)

(Y5)

Normally open (1 Form A)

2 A 250 V AC, 2 A 30 V DC

5 to 24 V DC

Output points per common

Operating load voltage range

4.75 to 26.4 V DC

Approx. 10 ms

Max. load current

0.5 A

Approx. 8 ms

Max. surge current

1 A

Min. 2 × 107 operations

Min. 105 operations (resistive load)

Output points per common

OFF state leakage current

100 µA or less

ON state voltage drop

1.5 V or less

LCD display (I/O monitor mode)

50 µs or less (For Y0 and Y1), 1 ms or less (For Y2,Y3 and Y4) OFF to ON

ON to OFF 50 µs or less (For Y0 and Y1), 1 ms or less (For Y2,Y3 and Y4)

External power supply (For driving internal circuit)

21.6 to 26.4 V DC Voltage

6 mA/point (For Y0 and Y1) 3 mA/point (For Y2, Y3, and Y4) Current

LCD display (I/O monitor mode)

  • COM. port communication specifications ∗ 1)

∗1) When communicating between FP-e and other devices, it is recommneded to perform

resend processing. ∗2) For RS232C wiring, be sure to use shielded wires for higher noise immunity. ∗3) Set the baud rate of RS485 with the FP-e system register and FP-e internal switch.

COM. port type

RS232C ∗ 2) RS485

Isolation status with the internal circuit Non-isolated Isolated

Set the baud rate of RS232C with the FP-e system register. ∗4) When sending a command from the FP-e is completed in RS485 communication, send a

Transmission distance 15 m 1200 m

response from the receiving device to the FP-e after the following time has elapsed: 9600 bit/s: 2 ms or longer 19200 bit/s: 1 ms or longer It takes at least 1 scan time (at least 2 ms) for the FP-e to send back a response after received the command. ∗5) When our C-NET Adapter or RS485 device other than recommended is connected in the

Baud rate ∗3) 300, 600, 1200, 2400, 4800, 9600, 19200 bit/s 9600,19200 bit/s ∗4)

system, the maximum connection number is limited to 32 units. ∗6) For a RS485 converter on the computer side, SI-35 (from LINE EYE Co., Ltd.) is

Synchro system Synchronous communication method

recommended. When SI-35 is used in the system, up to 99 units can be connected.

Stop bit1 bit/2 bit
ParityNot available/Available (Odd number/Even number)

Data length 7 bit/8 bit

Beginning codeSTX available/STX not available
Ending codeCR/CR+LF/not available/ETX

— 99 ∗5) ∗6) Data output order

Starting from 0 bits per character

No. of connected units

  • General-purpose communication
  • Computer link

19200 bit/s 9600 bit/s

  • Dimensions
  • Wiring diagram
  • Input connector (Standard type)

COM

COM

COM

X0 X1 X2 X3 X4 X5 A0+ A0− A1+ A1−

X0 X1 X2 X3 X4 X5 X6 X7

TC0

  • Power supply/COM. port connector (RS232C type)

TC1

24 V DC

  • Output connector

Ground Send data (Output) Receive data (Input) Signal Ground

COM. port (RS232C)

SD RD SG

+ − Y0 Y1 Y2 Y3 Y4 YC Y5 COM

(Terminal station) (Ordinary station)

24 V DC 24 V DC

Y5

COM. port (RS485)

COM. port (RS485)

COM

E

E

Clearwater Tech - Phone800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@ clrwtr.com 01/2004
Show 48 more labels / short text on this page
Item · Description · Item · Description · Insulation method · Optical coupler · Output type · Output type · Open collector · Rated control capacity · Rated load voltage · 1 point/common · Response time · OFF to ON · ON to OFF · Mechanical · Life time · 5 points/common · Electrical · Surge absorber · None · Operating indicator · Response time · Surge absorber · Zener diode · Operating indicator · Item · Description · Communication method Half-duplex · Transmission format · Communication mode · (mm) · (Thermocouple input type) · Internal circuit · Xn · + − · (+) · Internal circuit · Y0 to Y4 · (RS485 type) · (−) · + − · + − · Internal circuit · Ground · Ground · Power · Short
Page 8 of the Panasonic Network Adaptor user manual — Asia
Page 8 · click to enlarge
Page 8

FP-e Options

  • Options

Backup battery Included with calendar timer type

Rubber gasket Included with unit

Mounting frame Included with unit

Panel cover Color: Black

Part No.: AFPG804

Part No.: ATC18002

Part No.: AT8-DA4

Part No.: AFPE803 (20 sets)

Programming tool software Control FPWIN Pro Part No.: FPWINPROSEN5 (Small version, English manual) FPWINPROSFR5 (Small version, French manual) FPWINPROSDE5 (Small version, German manual) FPWINPROFEN5 (Full version, English manual) FPWINPROFFR5 (Full version, French manual) FPWINPROFDE5 (Full version, German manual)

Protective cover

Terminal socket set 4 type sockets, additional part

Programming tool software

Control FPWIN GR Part No.: FPWINGRF2 (Full version)

Part No.: AQM4803

Part No.: AFPE804

Programming cable

Part No.: AFC8513

Matsushita Electric Works

Please contact our Global Sales Companies in:

Europe

Europe Matsushita Electric Works (Europe) AG Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Tel. (08024) 648-0, Fax (08024) 648-111, www.mew-europe.com Austria Matsushita Electric Works Austria GmbH Josef Madersperger Straße 2, A-2362 Biedermannsdorf, Tel. (02236) 26846, Fax (02236) 46133, www.matsushita.at Benelux Matsushita Electric Works Benelux B.V. De Rijn 4, (Postbus 211), 5684 PJ Best, (5680 AE Best), Netherlands,Tel. (0499) 372727, Fax (0499) 372185, www.matsushita.nl or www.matsushita.be France Matsushita Electric Works France S.A.R.L. B.P. 44, F-91371 Verrières le Buisson CEDEX, Tél. 01 60135757, Fax 01 60135758, www.matsushita-france.fr Germany Matsushita Electric Works Deutschland GmbH Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Tel. (08024) 648-0, Fax (08024) 648-555, www.matsushita.de Ireland Matsushita Electric Works UK Ltd. Irish Branch Office, Waverley, Old Naas Road, Bluebell, Dublin 12, Republic of Ireland, Tel: (01) 4600969, Fax: (01) 4601131, www.matsushita.ie Italy Matsushita Electric Works Italia s.r.l. Via del Commercio 3-5 (Z.I. Ferlina), I-37012 Bussolengo (VR), Tel. (045) 6752711, Fax (045) 6700444, www.matsushita.it Portugal Matsushita Electric Works España S.A. Portuguese Branch Office, Avda 25 de Abril, Edificio Alvorada 5-ºE, 2750-512 Cascais, Portugal, Tel. (21) 4828266, Fax (21) 4827421 Scandinavia Matsushita Electric Works Scandinavia AB Sjöängsvägen 10, 19272 Sollentuna, Sweden, Tel. (08) 59476680, Fax (08) 59476690, www.matsushita.se Spain Matsushita Electric Works España S.A. Parque Empresarial Barajas, San Severo 20, 28042 Madrid, Tel. (91) 3293875, Fax (91) 3292976, www.matsushita.es Switzerland Matsushita Electric Works Schweiz AG Grundstrasse 8, CH-6343 Rotkreuz, Tel. (041) 7997050, Fax (041) 7997055, www.matsushita.ch United Kingdom Matsushita Electric Works UK Ltd. Sunrise Parkway, Linford Wood East, Milton Keynes, MK14 6LF, England, Tel. (01908) 231555, Fax (01908) 231599, www.matsushita.co.uk

North & South America

USA Aromat Corporation Head Office USA 629 Central Avenue, New Providence, N.J. 07974, Tel. 1-908-464-3550, Fax 1-908-464-8513, www.aromat.com

Asia

China Matsushita Electric Works Ltd. China Office 2013, Beijing Fortune, Building No. 5, Dong San Huan Bei Lu, Chaoyang District, Beijing, Tel. 86-10-6590-8646, Fax 86-10-6590-8647 Hong Kong Matsushita Electric Works Ltd. Hong Kong Rm1601, 16/F, Tower 2, The Gateway, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong, Tel. (852) 2956-3118, Fax (852) 2956-0398 Japan Matsushita Electric Works Ltd. 1048 Kadoma, Kadoma-shi, Osaka 571-8686, Japan, Tel. 06-6908-1050, Fax 06-6908-5781, www.mew.co.jp/e-acg/ Singapore Matsushita Electric Works 101 Thomson Road, #25-03/05, United Square, Singapore 307591, Tel. (65) 6255-5473, Fax (65) 6253-5689 (Asia Pacific) Pte. Ltd.

Copyright © 2004 • Printed in Germany

Clearwater Tech - Phone800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@ clrwtr.com

4150 eu en 01/04

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
X3count input (ch. 2), X4: count input (ch. 3), X5: reset input Note 5) p.5

Ask about the Panasonic Network Adaptor

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Panasonic Network Adaptor

Be the first to ask — other owners or our team will answer.

Original document

Panasonic Network Adaptor manual PDF

8 pages·745 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…