ORDERING INFORMATION

Remarks: Not every combination is available. Please refer to the following table, “PRODUCT TYPES”.
TERMINAL VARIATION Standard types, reversed action types and oil tight types are available in two terminal designs, solder and screw terminals, as shown in the above columns: Differences in dimension between solder and screw terminals are as follows;
N.O.
CIRCUT
N.C.
20.2 19.8
M4 screw P0.7
mm Screw terminal · Solder terminal · Terminal plate

Actuator Solder terminal Screw terminal Rigid lever AM1511KF AM1711KF Rigid short roller lever AM1514KF AM1714KF Rigid roller lever AM1513KF AM1713KF
Remarks: 1. Standard part number indicates UL/C-UL mark.
Type Voltage Resistive load
Inductive load (cos φ = 0.6 to 0.7)
Motor or lamp load N.C. N.O.
(cos φ = 1)
125 V AC 10 A 6 A 3 A 1.5 A 250 V AC 10 A 6 A 2 A 1 A 480 V AC 1 A 0.5 A — — 125 V DC 0.5 A 0.05 A — — 250 V DC 0.25 A 0.03 A — —
Standard types One way types Reversed action types
125 V AC 10 A 6 A 3 A 1.5 A 250 V AC 10 A 6 A 2 A 1.0 A 125 V DC 0.5 A 0.05 A — —
Pin plunger types (O.T.: specified value) Min. 2 ×107 (60 cpm) (at rated overtravel) (Oil tight: Min. 1.5 ×106)
Other types (O.T.: specified value) Min. 5 ×106 (60 cpm) (at rated overtravel) (Oil tight: Min. 1.5 ×106)
Electrical (O.T.: Max.) Min. 5 ×105 (20 cpm) (at rated load) (Oil tight: Min. 1.5 ×105) Insulation resistance Min. 100 MΩ(at 500 V DC)
Between open terminals 1,000 Vrms for 1 min. Between each terminal and other exposed metal parts 2,000 Vrms for 1 min. Between each terminal and ground 2,000 Vrms for 1 min. Contact resistance (initial) (by voltage drop, 1 A, 6–8 V DC) Max. 50 mΩ Vibration resistance (Pin plunger type) Single amplitude: 0.75 mm, 10 to 55 Hz (contact opening: max. 1 msec.)
Pin plunger types Min. 300 m/s2 (contact opening: max. 1 msec.) Other types Min. 50 m/s2 (contact opening: max. 1 msec.) Allowable operating speed (at no load) 0.1 to 1,000 mm/sec. (at pin plunger position) Max. operating cycle rate (at no load) 240 cpm Ambient temperature –25°C to +80°C (no freezing at low temperature) Weight Approx. 20 to 55 g



23.3±0.3
P.T.
O.P.
14.6 15
9.1 5.4
4.2 +0.1 −0.05
4.2 dia. hole +0.1 −0.05
4.5±0.1 25.4±0.1 49.2 11.9


23.3±0.3
4 dia. 6.35 dia.
O.P.

P.T. 0.4 max. 23.3 ±0.3
7.1 dia.
21.2 O.P.
±0.5
–0.05 +0.10 4.2
14.3 14.5
4.2 +0.10 –0.05 dia.
R8 Operating force, max. 3.63 N

P.T. 0.4 max. 23.3 ±0.3
8.25 dia.
21.8 O.P.
±0.8
±0.5
–0.05 +0.10 4.2
4.2 +0.10 –0.05 dia.

Panel mount roller plunger mm General tolerance: ±0.4

P.T. 0.4 max. 23.3 ±0.3
Roller 12.7 dia. × 4.6
: Plastic
33.3 O.P.
±1.2
16 ±0.5 –0.05 +0.10 4.2
4.2 +0.10 –0.05 dia.
Panel mount cross roller plunger

P.T. 0.4 max. 23.3 ±0.3
: Plastic Roller 12.7 dia. × 4.6
33.3 O.P.
±1.2
16 ±0.5 –0.05 +0.10 4.2
4.2 +0.10 –0.05 dia.
Dimensions and Operating characteristics are the same as those of Panel mount roller plunger type. However, the roller joins the switch body at an angle of 90°.


49.6±0.8
Flexible roller leaf lever


46±0.8



Rigid short roller lever



20.1±0.5


27.8 max. 20.1±0.5 F.P. O.P.
Rigid roller lever

Rigid roller lever mm General tolerance: ±0.4


O.P. F.P.
34.1 max.
20.1±0.5


20.1±0.5
16.9±0.8 F.P.
O.P.
4.2 dia. hole +0.1 −0.05
4.2 +0.1 −0.05
4.5±0.1 25.4±0.1
11.9 11.9
Rigid short roller lever




20.1±0.5
Rigid roller lever



Rigid short roller lever


Plunger seal Roller 9.5 dia.×4: Plastic
20.1±0.5 16.9±0.8


Plunger seal Roller 9.5 dia.×4: Plastic
20.1±0.5 16.9±0.8
Plunger seal · Rigid roller lever

AM1 NOTES 1. Regarding fastening of switch body 1) In fastening the switch body, use M4 mounting screws to attach switches with the torque 1.5 N·m or less. 2) After mounting and wiring, the insulation distance between ground and each terminal should be confirmed as sufficient. 2. Adjustment of the operating device The operating device should be positioned so that it applies no stress to the pushbutton or actuator when the switch is in the open position. If this condition is exceeded, the mechanical and electrical performance will be impaired. In addition, the force applied by the operating device should be in a perpendicular direction. Even if the pushbutton is used in the full total travel position, there will be no influence on the life of the switch.