EN
Panasonic logo
Official user manual

Panasonic 470

132 pages·3.5 MB·Switch·PDF·ENDEFRITNLJA
Panasonic 470
Table of Contents 209 sections Configuration — SystemMonitoring · Contents · Preface · About this guide · … ShowHide
Configuration — SystemMonitoringp.1Contentsp.7Prefacep.11About this guidep.11Network management tools and interfacesp.11Before you beginp.12Text conventionsp.12Related publicationsp.13Obtaining technical assistancep.14Network monitoringp.15System Logp.15System Log screenp.15Displaying most recent log entry firstp.16Port mirroringp.17Port-based mirroring configurationp.18Address-based mirroring configurationp.19Port mirroring configuration rulesp.21Port Mirroring Configuration screenp.22Port Statistics screenp.25Configuring network monitoring using CLIp.31Setting the system event logp.31Enabling remote loggingp.35show loggingp.35logging remote enable commandp.36no logging remote enable commandp.37logging remote address commandp.37no logging remote address commandp.37logging remote level commandp.38no logging remote level commandp.38default logging remote level commandp.39Using port mirroringp.39show port-mirroring commandp.39port-mirroring commandp.40no port-mirroring commandp.41Displaying port statisticsp.41show port-statistics commandp.42clear-stats commandp.43Configuring network monitoring using Device Managerp.45System Log Settings tabp.45Remote System Log tabp.47Graphing chassis statisticsp.49IP tabp.49ICMP In tabp.53ICMP Out tabp.54Graphing port statisticsp.56Interface tab for graphing portsp.57Ethernet Errors tab for graphing portsp.59Bridge tab for graphing portsp.62Configuring network monitoring using Web-based managementp.65Viewing the system logp.65Configuring port mirroringp.67Viewing system statisticsp.71Viewing port statisticsp.71Viewing all port errorsp.74Viewing interface statisticsp.76Viewing Ethernet error statisticsp.77Viewing transparent bridging statisticsp.79Monitoring MLT trafficp.81Configuring RMON using the CLIp.83show rmon alarmp.83show rmon eventp.84show rmon historyp.84show rmon statsp.85rmon alarmp.86no rmon alarmp.87rmon eventp.88no rmon eventp.88rmon historyp.88no rmon historyp.89rmon statsp.89no rmon statsp.90Configuring RMON using Device Managerp.91Working with RMON informationp.91RMON historyp.92Creating a historyp.92Disabling historyp.94Viewing RMON history statisticsp.94Enabling Ethernet statistics gatheringp.96Disabling Ethernet statistics gatheringp.98RMON Alarmsp.98How RMON alarms workp.98Creating alarmsp.100Alarm Manager examplep.100Viewing RMON statisticsp.103RMON eventsp.106How events workp.106Viewing an eventp.106Creating an eventp.108Deleting an eventp.109RMON Log informationp.109RMON tab for graphing portsp.110Configuring RMON using Web-based managementp.113Configuring RMON fault threshold parametersp.113Creating an RMON fault thresholdp.113Deleting an RMON threshold configurationp.116Viewing the RMON fault event logp.117Viewing RMON Ethernet statisticsp.118Viewing RMON historyp.120Quick steps for port mirroringp.123Configuring port mirroringp.123Indexp.126Figuresp.16Figure 1 System Log screenp.16Figure 2 Port-based mirroring configuration examplep.18Figure 3 Port Mirroring Configuration port-based screen examplep.19Figure 4 Address-based mirroring configuration examplep.20Figure 5 Port Mirroring Configuration address-based screen examplep.21Figure 6 Port Mirror Configuration screenp.22Figure 7 Port statistics screenp.26Figure 8 show logging sort-reverse command outputp.32Figure 9 show logging config command outputp.36Figure 10 show port-mirroring command outputp.39Figure 11 show port-statistics command outputp.43Figure 12 System Log Settings tabp.46Figure 13 Remote System Log tabp.48Figure 14 Graph Chassis dialog box -- Chassis SNMP tabp.50Figure 15 Graph Chassis dialog box -- IP tabp.51Figure 16 Graph Chassis dialog box -- ICMP In tabp.53Figure 17 Graph Chassis dialog box -- ICMP Out tabp.55Figure 18 Interface tab for graphing portsp.57Figure 19 Graph Port dialog box -- Port Ethernet Errors tabp.60Figure 20 Graph Port dialog box -- Bridge tabp.63Figure 21 System Log pagep.66Figure 22 Port Mirroring pagep.68Figure 23 Port pagep.72Figure 24 Port Error Summary pagep.75Figure 25 Interface pagep.76Figure 26 Ethernet Errors pagep.78Figure 27 Transparent Bridging pagep.80Figure 28 Utilization pagep.81Figure 29 show rmon alarm command outputp.84Figure 30 show rmon event command outputp.84Figure 31 show rmon history command outputp.85Figure 32 show rmon stats command outputp.86Figure 33 History tabp.92Figure 34 RmonControl, Insert History dialog boxp.93Figure 35 Rmon History statisticsp.95Figure 36 RmonControl dialog box -- Ether Stats tabp.96Figure 37 RmonControl, Insert Ether Stats dialog boxp.97Figure 38 RmonControl, Insert Ether Stats dialog box port listp.97Figure 39 How alarms firep.99Figure 40 Alarm example -- threshold less than 260p.100Figure 41 Alarm Manager dialog boxp.101Figure 42 Alarm variable listp.102Figure 43 RmonAlarms dialog box -- Alarms tabp.104Figure 44 RmonAlarms dialog box -- Events tabp.107Figure 45 Insert Events dialog boxp.108Figure 46 New event in the Events tabp.108Figure 47 Log tabp.109Figure 48 Graph Port dialog box -- RMON tabp.111Figure 49 RMON Threshold pagep.114Figure 50 RMON Event Log pagep.117Figure 51 RMON Ethernet pagep.118Figure 52 RMON History pagep.120Figure 53 Configuring port mirroring (1 of 2)p.124Figure 54 Configuring port mirroring (2 of 2)p.125Tablesp.16Table 1 System Log screen fieldsp.16Table 2 Port Mirroring Configuration screen fieldsp.23Table 3 Monitoring modesp.24Table 4 Port Statistics screen fieldsp.26Table 5 show logging command parameters and variablesp.32Table 6 logging command parameters and variablesp.33Table 7 set logging command parameters and variablesp.33Table 8 clear logging command parameters and valuesp.35Table 9 show logging command parameters and variablesp.36Table 10 logging remote address command parameters and variablesp.37Table 11 logging remote level command parameters and variablesp.38Table 12 port-mirroring command parameters and variablesp.40Table 13 show port-statistics command parameters and variablesp.42Table 14 clear-stats command parameters and variablesp.44Table 15 System Log Settings tab itemsp.46Table 16 Remote System Log tab itemsp.48Table 17 Chassis IP tab fieldsp.51Table 18 ICMP In tab fieldsp.54Table 19 ICMP Out tab fieldsp.55Table 20 Port Interface tab fields for multiple portsp.58Table 21 Ethernet Errors tab fieldsp.60Table 22 Bridge tab fieldsp.63Table 23 System Log page fieldsp.66Table 24 Port Mirroring page itemsp.68Table 25 Port-based monitoring modesp.70Table 26 Address-based monitoring modesp.71Table 27 Port page itemsp.72Table 28 Port Error Summary Table fieldsp.75Table 29 Interface page itemsp.76Table 30 Ethernet Errors page itemsp.78Table 31 Transparent Bridging page itemsp.80Table 32 Utilization page itemsp.81Table 33 rmon alarm command parameters and variablesp.86Table 34 no rmon alarm command parameters and variablesp.87Table 35 rmon event command parameters and variablesp.88Table 36 no rmon event command parameters and variablesp.88Table 37 rmon history command parameters and variablesp.89Table 38 no rmon history command parameters and variablesp.89Table 39 rmon stats command parameters and variablesp.90Table 40 no rmon stats command parameters and variablesp.90Table 41 History tab fieldsp.93Table 42 Rmon History statistics tab fieldsp.95Table 43 Ether Stats tab fieldsp.97Table 44 Rmon Insert Alarm dialog box fieldsp.103Table 45 Alarms tab fieldsp.104Table 46 Events tab fieldsp.107Table 47 Log tab fieldsp.110Table 48 RMON tab fieldsp.111Table 49 RMON Threshold page itemsp.114Table 50 RMON Event Log page fieldsp.117Table 51 RMON Ethernet page itemsp.118Table 52 RMON History page itemsp.121
Page 1 of the Panasonic 470 user manual — NN47210-503 (217107-B)
Page 1 · click to enlarge
Page 1
Panasonic 470 — Configuration — SystemMonitoring diagram (page 1)
Fig. 1 · Configuration — SystemMonitoring

scroll up or down the page to see the beginning of the referenced section.

NN47210-503 (217107-B)

Page 2 of the Panasonic 470 user manual — Configuration — SystemMonitoring
Page 2 · click to enlarge
Page 2
Document statusStandard Document version: 01.01 Document date: 22 February 2007

Copyright © 2005-2007, Nortel Networks All Rights Reserved.

The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel Networks.

The software described in this document is furnished under a license agreement and may be used only in accordance with the terms of that license. The software license agreement is included in this document.

Trademarks *Nortel, Nortel Networks, the Nortel logo, and the Globemark are trademarks of Nortel Networks.

All other products or services may be trademarks, registered trademarks, service marks, or registered service marks of their respective owners. The asterisk after a name denotes a trademarked item.

Restricted rights legend Use, duplication, or disclosure by the United States Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013.

Notwithstanding any other license agreement that may pertain to, or accompany the delivery of, this computer software, the rights of the United States Government regarding its use, reproduction, and disclosure are as set forth in the Commercial Computer Software-Restricted Rights clause at FAR 52.227-19.

Statement of conditions In the interest of improving internal design, operational function, and/or reliability, Nortel Networks reserves the right to make changes to the products described in this document without notice.

Nortel Networks does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.

Portions of the code in this software product may be Copyright © 1988, Regents of the University of California. All rights reserved. Redistribution and use in source and binary forms of such portions are permitted, provided that the above copyright notice and this paragraph are duplicated in all such forms and that any documentation, advertising materials, and other materials related to such distribution and use acknowledge that such portions of the software were developed by the University of California, Berkeley. The name of the University may not be used to endorse or promote products derived from such portions of the software without specific prior written permission.

SUCH PORTIONS OF THE SOFTWARE ARE PROVIDED "AS IS" AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

In addition, the program and information contained herein are licensed only pursuant to a license agreement that contains restrictions on use and disclosure (that may incorporate by reference certain limitations and notices imposed by third parties).

Nortel Networks software license agreement This Software License Agreement ("License Agreement") is between you, the end-user ("Customer") and Nortel Networks Corporation and its subsidiaries and affiliates ("Nortel Networks"). PLEASE READ THE FOLLOWING CAREFULLY. YOU MUST ACCEPT THESE LICENSE TERMS IN ORDER TO DOWNLOAD AND/OR USE THE SOFTWARE. USE OF THE SOFTWARE CONSTITUTES YOUR ACCEPTANCE OF THIS LICENSE AGREEMENT. If you do not accept these terms and conditions, return the Software, unused and in the original shipping container, within 30 days of purchase to obtain a credit for the full purchase price.

Page 3 of the Panasonic 470 user manual — Configuration — SystemMonitoring
Page 3 · click to enlarge
Page 3

"Software" is owned or licensed by Nortel Networks, its parent or one of its subsidiaries or affiliates, and is copyrighted and licensed, not sold. Software consists of machine-readable instructions, its components, data, audio-visual content (such as images, text, recordings or pictures) and related licensed materials including all whole or partial copies. Nortel Networks grants you a license to use the Software only in the country where you acquired the Software. You obtain no rights other than those granted to you under this License Agreement. You are responsible for the selection of the Software and for the installation of, use of, and results obtained from the Software.

1. Licensed Use of Software. Nortel Networks grants Customer a nonexclusive license to use a copy of the Software on only one machine at any one time or to the extent of the activation or authorized usage level, whichever is applicable. To the extent Software is furnished for use with designated hardware or Customer furnished equipment ("CFE"), Customer is granted a nonexclusive license to use Software only on such hardware or CFE, as applicable. Software contains trade secrets and Customer agrees to treat Software as confidential information using the same care and discretion Customer uses with its own similar information that it does not wish to disclose, publish or disseminate. Customer will ensure that anyone who uses the Software does so only in compliance with the terms of this Agreement. Customer shall not a) use, copy, modify, transfer or distribute the Software except as expressly authorized; b) reverse assemble, reverse compile, reverse engineer or otherwise translate the Software; c) create derivative works or modifications unless expressly authorized; or d) sublicense, rent or lease the Software. Licensors of intellectual property to Nortel Networks are beneficiaries of this provision. Upon termination or breach of the license by Customer or in the event designated hardware or CFE is no longer in use, Customer will promptly return the Software to Nortel Networks or certify its destruction. Nortel Networks may audit by remote polling or other reasonable means to determine Customer’s Software activation or usage levels. If suppliers of third party software included in Software require Nortel Networks to include additional or different terms, Customer agrees to abide by such terms provided by Nortel Networks with respect to such third party software.

2. Warranty. Except as may be otherwise expressly agreed to in writing between Nortel Networks and Customer, Software is provided "AS IS" without any warranties (conditions) of any kind. NORTEL NETWORKS DISCLAIMS ALL WARRANTIES (CONDITIONS) FOR THE SOFTWARE, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABLITITY AND FITNESS FOR A PARTICULAR PURPOSE AND ANY WARRANTY OF NON-INFRINGEMENT. Nortel Networks is not obligated to provide support of any kind for the Software. Some jurisdictions do not allow exclusion of implied warranties, and, in such event, the above exclusions may not apply.

3. Limitation of Remedies. IN NO EVENT SHALL NORTEL NETWORKS OR ITS AGENTS OR SUPPLIERS BE LIABLE FOR ANY OF THE FOLLOWING: a) DAMAGES BASED ON ANY THIRD PARTY CLAIM; b) LOSS OF, OR DAMAGE TO, CUSTOMER’S RECORDS, FILES OR DATA; OR c) DIRECT, INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES (INCLUDING LOST PROFITS OR SAVINGS), WHETHER IN CONTRACT, TORT OR OTHERWISE (INCLUDING NEGLIGENCE) ARISING OUT OF YOUR USE OF THE SOFTWARE, EVEN IF NORTEL NETWORKS, ITS AGENTS OR SUPPLIERS HAVE BEEN ADVISED OF THEIR POSSIBILITY. The forgoing limitations of remedies also apply to any developer and/or supplier of the Software. Such developer and/or supplier is an intended beneficiary of this Section. Some jurisdictions do not allow these limitations or exclusions and, in such event, they may not apply.

4. General

a. If Customer is the United States Government, the following paragraph shall apply: All Nortel Networks Software available under this License Agreement is commercial computer software and commercial computer software documentation and, in the event Software is licensed for or on behalf of the United States Government, the respective rights to the software and software documentation are governed by Nortel Networks standard commercial license in accordance with U.S. Federal Regulations at 48 C.F.R. Sections 12.212 (for non-Odd entities) and 48 C.F.R. 227.7202 (for Odd entities).

b. Customer may terminate the license at any time. Nortel Networks may terminate the license if Customer fails to comply with the terms and conditions of this license. In either event, upon termination, Customer must either return the Software to Nortel Networks or certify its destruction.

c. Customer is responsible for payment of any taxes, including personal property taxes, resulting from Customer’s use of the Software. Customer agrees to comply with all applicable laws including all applicable export and import laws and regulations.

d. Neither party may bring an action, regardless of form, more than two years after the cause of the action arose.

e. The terms and conditions of this License Agreement form the complete and exclusive agreement between Customer and Nortel Networks.

Page 4 of the Panasonic 470 user manual — Configuration — SystemMonitoring
Page 4 · click to enlarge
Page 4

f. This License Agreement is governed by the laws of the country in which Customer acquires the Software. If the Software is acquired in the United States, then this License Agreement is governed by the laws of the state of New York.

Page 5 of the Panasonic 470 user manual — Revision History
Page 5 · click to enlarge
Page 5

Revision History

VersionReason for revision 01.01Updated software and document references for Release 3.7 software.
Page 6 of the Panasonic 470 user manual — Configuration — SystemMonitoring
Page 6 · click to enlarge
Page 6

6 Revision History

Page 7 of the Panasonic 470 user manual — Table of Contents
Page 7 · Contents
Contents

Contents

Configuration — SystemMonitoringp.1Contentsp.7Prefacep.11About this guidep.11Network management tools and interfacesp.11Before you beginp.12Text conventionsp.12Related publicationsp.13Obtaining technical assistancep.14Network monitoringp.15System Logp.15System Log screenp.15Displaying most recent log entry firstp.16Port mirroringp.17Port-based mirroring configurationp.18Address-based mirroring configurationp.19Port mirroring configuration rulesp.21Port Mirroring Configuration screenp.22Port Statistics screenp.25Configuring network monitoring using CLIp.31Setting the system event logp.31Enabling remote loggingp.35show loggingp.35logging remote enable commandp.36no logging remote enable commandp.37logging remote address commandp.37no logging remote address commandp.37logging remote level commandp.38no logging remote level commandp.38default logging remote level commandp.39Using port mirroringp.39show port-mirroring commandp.39port-mirroring commandp.40no port-mirroring commandp.41Displaying port statisticsp.41show port-statistics commandp.42clear-stats commandp.43Configuring network monitoring using Device Managerp.45System Log Settings tabp.45Remote System Log tabp.47Graphing chassis statisticsp.49IP tabp.49ICMP In tabp.53ICMP Out tabp.54Graphing port statisticsp.56Interface tab for graphing portsp.57Ethernet Errors tab for graphing portsp.59Bridge tab for graphing portsp.62Configuring network monitoring using Web-based managementp.65Viewing the system logp.65Configuring port mirroringp.67Viewing system statisticsp.71Viewing port statisticsp.71Viewing all port errorsp.74Viewing interface statisticsp.76Viewing Ethernet error statisticsp.77Viewing transparent bridging statisticsp.79Monitoring MLT trafficp.81Configuring RMON using the CLIp.83show rmon alarmp.83show rmon eventp.84show rmon historyp.84show rmon statsp.85rmon alarmp.86no rmon alarmp.87rmon eventp.88no rmon eventp.88rmon historyp.88no rmon historyp.89rmon statsp.89no rmon statsp.90Configuring RMON using Device Managerp.91Working with RMON informationp.91RMON historyp.92Creating a historyp.92Disabling historyp.94Viewing RMON history statisticsp.94Enabling Ethernet statistics gatheringp.96Disabling Ethernet statistics gatheringp.98RMON Alarmsp.98How RMON alarms workp.98Creating alarmsp.100Alarm Manager examplep.100Viewing RMON statisticsp.103RMON eventsp.106How events workp.106Viewing an eventp.106Creating an eventp.108Deleting an eventp.109RMON Log informationp.109RMON tab for graphing portsp.110Configuring RMON using Web-based managementp.113Configuring RMON fault threshold parametersp.113Creating an RMON fault thresholdp.113Deleting an RMON threshold configurationp.116Viewing the RMON fault event logp.117Viewing RMON Ethernet statisticsp.118Viewing RMON historyp.120Quick steps for port mirroringp.123Configuring port mirroringp.123Indexp.126Figuresp.16Figure 1 System Log screenp.16Figure 2 Port-based mirroring configuration examplep.18Figure 3 Port Mirroring Configuration port-based screen examplep.19Figure 4 Address-based mirroring configuration examplep.20Figure 5 Port Mirroring Configuration address-based screen examplep.21Figure 6 Port Mirror Configuration screenp.22Figure 7 Port statistics screenp.26Figure 8 show logging sort-reverse command outputp.32Figure 9 show logging config command outputp.36Figure 10 show port-mirroring command outputp.39Figure 11 show port-statistics command outputp.43Figure 12 System Log Settings tabp.46Figure 13 Remote System Log tabp.48Figure 14 Graph Chassis dialog box -- Chassis SNMP tabp.50Figure 15 Graph Chassis dialog box -- IP tabp.51Figure 16 Graph Chassis dialog box -- ICMP In tabp.53Figure 17 Graph Chassis dialog box -- ICMP Out tabp.55Figure 18 Interface tab for graphing portsp.57Figure 19 Graph Port dialog box -- Port Ethernet Errors tabp.60Figure 20 Graph Port dialog box -- Bridge tabp.63Figure 21 System Log pagep.66Figure 22 Port Mirroring pagep.68Figure 23 Port pagep.72Figure 24 Port Error Summary pagep.75Figure 25 Interface pagep.76Figure 26 Ethernet Errors pagep.78Figure 27 Transparent Bridging pagep.80Figure 28 Utilization pagep.81Figure 29 show rmon alarm command outputp.84Figure 30 show rmon event command outputp.84Figure 31 show rmon history command outputp.85Figure 32 show rmon stats command outputp.86Figure 33 History tabp.92Figure 34 RmonControl, Insert History dialog boxp.93Figure 35 Rmon History statisticsp.95Figure 36 RmonControl dialog box -- Ether Stats tabp.96Figure 37 RmonControl, Insert Ether Stats dialog boxp.97Figure 38 RmonControl, Insert Ether Stats dialog box port listp.97Figure 39 How alarms firep.99Figure 40 Alarm example -- threshold less than 260p.100Figure 41 Alarm Manager dialog boxp.101Figure 42 Alarm variable listp.102Figure 43 RmonAlarms dialog box -- Alarms tabp.104Figure 44 RmonAlarms dialog box -- Events tabp.107Figure 45 Insert Events dialog boxp.108Figure 46 New event in the Events tabp.108Figure 47 Log tabp.109Figure 48 Graph Port dialog box -- RMON tabp.111Figure 49 RMON Threshold pagep.114Figure 50 RMON Event Log pagep.117Figure 51 RMON Ethernet pagep.118Figure 52 RMON History pagep.120Figure 53 Configuring port mirroring (1 of 2)p.124Figure 54 Configuring port mirroring (2 of 2)p.125Tablesp.16Table 1 System Log screen fieldsp.16Table 2 Port Mirroring Configuration screen fieldsp.23Table 3 Monitoring modesp.24Table 4 Port Statistics screen fieldsp.26Table 5 show logging command parameters and variablesp.32Table 6 logging command parameters and variablesp.33Table 7 set logging command parameters and variablesp.33Table 8 clear logging command parameters and valuesp.35Table 9 show logging command parameters and variablesp.36Table 10 logging remote address command parameters and variablesp.37Table 11 logging remote level command parameters and variablesp.38Table 12 port-mirroring command parameters and variablesp.40Table 13 show port-statistics command parameters and variablesp.42Table 14 clear-stats command parameters and variablesp.44Table 15 System Log Settings tab itemsp.46Table 16 Remote System Log tab itemsp.48Table 17 Chassis IP tab fieldsp.51Table 18 ICMP In tab fieldsp.54Table 19 ICMP Out tab fieldsp.55Table 20 Port Interface tab fields for multiple portsp.58Table 21 Ethernet Errors tab fieldsp.60Table 22 Bridge tab fieldsp.63Table 23 System Log page fieldsp.66Table 24 Port Mirroring page itemsp.68Table 25 Port-based monitoring modesp.70Table 26 Address-based monitoring modesp.71Table 27 Port page itemsp.72Table 28 Port Error Summary Table fieldsp.75Table 29 Interface page itemsp.76Table 30 Ethernet Errors page itemsp.78Table 31 Transparent Bridging page itemsp.80Table 32 Utilization page itemsp.81Table 33 rmon alarm command parameters and variablesp.86Table 34 no rmon alarm command parameters and variablesp.87Table 35 rmon event command parameters and variablesp.88Table 36 no rmon event command parameters and variablesp.88Table 37 rmon history command parameters and variablesp.89Table 38 no rmon history command parameters and variablesp.89Table 39 rmon stats command parameters and variablesp.90Table 40 no rmon stats command parameters and variablesp.90Table 41 History tab fieldsp.93Table 42 Rmon History statistics tab fieldsp.95Table 43 Ether Stats tab fieldsp.97Table 44 Rmon Insert Alarm dialog box fieldsp.103Table 45 Alarms tab fieldsp.104Table 46 Events tab fieldsp.107Table 47 Log tab fieldsp.110Table 48 RMON tab fieldsp.111Table 49 RMON Threshold page itemsp.114Table 50 RMON Event Log page fieldsp.117Table 51 RMON Ethernet page itemsp.118Table 52 RMON History page itemsp.121
Page 11 of the Panasonic 470 user manual — Network management tools and interfaces
Page 11 · click to enlarge
Page 11

Preface

About this guide

This guide provides information about system logging, displaying system statistics, and configuring network monitoring on the Nortel Ethernet Switch 460 and Nortel Ethernet Switch 470.

Network management tools and interfaces

The following are the management tools and interfaces available with the switch (for basic instructions on these tools, refer to the Nortel Ethernet Switch 460/470 Overview — System Configuration (NN47210-501)):

  • Console interface

The console interface (CI) allows you to configure and manage the switch locally or remotely. Access the CI menu and screens locally through a console terminal attached to your Ethernet Switch, remotely through a dial-up modem connection, or in-band through a Telnet session.

  • Web-based management

You can manage the network from the World Wide Web and can access the Web-based Graphical User Interface (GUI) through the HTML-based browser located on your network. The GUI allows you to configure, monitor, and maintain your network through web browsers. You can also download software using the web.

  • Java-based Device Manager

The Device Manager is a set of Java-based graphical network management applications that is used to configure and manage Ethernet Switches 460 and 470.

  • Command Line Interface (CLI)

The CLI is used to automate general management and configuration of the Ethernet Switches 460 and 470. Use the CLI through a Telnet connection or through the serial port on the console.

  • Any generic SNMP-based network management software
Page 12 of the Panasonic 470 user manual — Text conventions
Page 12 · click to enlarge
Page 12

You can use any generic SNMP-based network management software to configure and manage Ethernet Switches 460 and 470.

  • Telnet

Telnet allows you to access the CLI and CI menu and screens locally using an in-band Telnet session.

  • SSH

Secure Shell (SSH) is a client/server protocol that can provide a secure remote login with encryption of data, user name, and password. For details on SSH connections, refer to Nortel Ethernet Switch 460/470 Security — Configuration (NN47210-500).

  • Nortel Enterprise Policy Manager

The Nortel Enterprise Policy Manager (formerly Optivity Policy Services) allows you to configure the Ethernet Switches 460 and 470 with a single system.

Before you begin

This guide is intended for network administrators with the following background:

  • Basic knowledge of networks, bridging, and IP
  • Familiarity with networking concepts and terminology
  • Basic knowledge of network topologies

Before using this guide, you must complete the installation procedures discussed in Nortel Ethernet Switch 460-24T-PWR — Installation (NN47210-300) or Nortel Ethernet Switch 470 — Installation (NN47210-301).

Text conventions

angle brackets (< >) Indicate that you choose the text to enter based on the description inside the brackets. Do not type the brackets when entering the command.

ExampleIf the command syntax is ip default-gateway <XXX.XXX.XXX.XXX> , you enter ip default-gateway 192.32.10.12

braces ({}) Indicate required elements in syntax descriptions where there is more than one option. You must choose only one of the options. Do not type the braces when entering the command.

12 Preface

Page 13 of the Panasonic 470 user manual — Related publications
Page 13 · click to enlarge
Page 13
ExampleIf the command syntax is

http-server {enable | disable} the options are enable or disable.

brackets ([ ]) Indicate optional elements in syntax descriptions. Do not type the brackets when entering the command.

ExampleIf the command syntax is

show ip [bootp], you can enter either

show ip or show ip bootp.

Indicates command syntax and system output.

ExampleTFTP Server IP Address: 192.168.100.15

vertical line | Separates choices for command keywords and arguments. Enter only one of the choices. Do not type the vertical line when entering the command.

ExampleIf the command syntax is

cli password <serial | telnet>, you must enter either cli password serial or cli password telnet, but not both.

H.H.H. Enter a MAC address in this format (XXXX.XXXX.XXXX).

Related publications

For more information about managing or using the switches, refer to the following publications:

  • Release Notes — Software Release 3.7 (NN47210-400)
  • Nortel Ethernet Switch 460-24T-PWR — Installation (NN47210-300)
  • Nortel Ethernet Switch 470 — Installation (NN47210-301)
  • Nortel Ethernet Switch 460/470 Overview — System Configuration (NN47210-501)
  • Nortel Ethernet Switch 460/470 Security — Configuration (NN47210-500)

Related publications 13 · plain Courier text

Page 14 of the Panasonic 470 user manual — Obtaining technical assistance
Page 14 · click to enlarge
Page 14
  • Nortel Ethernet Switch 460/470 Configuration — Quality of Service and IP Filtering (NN47210-502)
  • Nortel Ethernet Switch 460/470 Configuration — IP Multicast Routing Protocols (NN47210-504)
  • Nortel Ethernet Switch 460/470 Configuration — VLANs, Spanning Tree, and Multilink Trunking (NN47210-505)
  • Installing Gigabit Interface Converters and Small Form Factor Pluggable Interface Converters (312865-B)

You can print selected technical manuals and release notes free, directly from the Internet. Go to www.nortel.com/support Find the product for which you need documentation. Then locate the specific category and model or version for your hardware or software product. Use Adobe* Acrobat Reader* to open the manuals and release notes, search for the sections you need, and print them on most standard printers. Go to the Adobe Systems web site to download a free copy of the Adobe Acrobat Reader.

Obtaining technical assistance

If you purchased a service contract for your Nortel product from a distributor or authorized reseller, contact the technical support staff for that distributor or reseller for assistance.

If you purchased a Nortel service program, contact one of the following Nortel Technical Solutions Centers:

Technical Solutions Center Telephone

Europe, Middle East, and Africa (33) (4) 92-966-968

North America (800) 4NORTEL or (800) 466-7835

Asia Pacific (61) (2) 9927-8800

Additional information about the Nortel Technical Solutions Centers is available from www.nortel.com/callus

An Express Routing Code (ERC) is available for many Nortel products and services. When you use an ERC, your call is routed to a technical support person who specializes in supporting that product or service. To locate an ERC for your product or service, go to www.nortel.com/erc

14 Preface · China (800) 810-5000

Page 15 of the Panasonic 470 user manual — System Log screen
Page 15 · click to enlarge
Page 15

Chapter 1 Network monitoring

The Ethernet Switches 460 and 470 provide features that allow you to monitor your network, display switch statistics, and log system events.

This chapter discusses the following topics:

  • "System Log" (page 15)
  • "Port mirroring" (page 17)
  • "Port Statistics screen" (page 25)

System Log

System Log messages operate as follows:

  • Non-volatile memory messages are retrievable after a system reset.
  • Messages can be viewed while the system is operational.
  • All non-volatile and dynamic memory messages are time stamped.
  • When you restart your system after a reset, the dynamic memory messages are deleted.
  • After a reset, all messages stored in non-volatile memory are copied to dynamic memory. The messages copied to dynamic memory are time stamped to zero (0).
  • Starting with Release 3.6 software, Ethernet Switches 460 and 470 save the last 100 commands entered to a command history log in NVRAM. This history is periodically copied from NVRAM to the remote syslog server. For details, refer to Nortel Ethernet Switch 460/470 Security — Configuration (NN47210-500) .

System Log screen

In the Console Interface, the System Log screen (Figure 1 "System Log screen" (page 16)) displays or clears messages obtained from system non-volatile memory or dynamic memory.

To open the System Log screen:

Page 16 of the Panasonic 470 user manual — Displaying most recent log entry first
Page 16 · click to enlarge
Page 16

16 Chapter 1 Network monitoring

è Choose Display System Log (or type y) from the main menu.

Figure 1 System Log screen

Panasonic 470 — Displaying most recent log entry first diagram (page 16)
Fig. 2 · Displaying most recent log entry first

Displaying most recent log entry first

This option allows you to view the system log with the most recent entry displayed first; the rest of the log entries are listed in reverse chronological order.

Table 1 "System Log screen fields" (page 16) describes the System Log screen fields.

Table 1 System Log screen fields

Display Messages From This field allows you to select the memory source your messages are obtained from. Choose Non Volatile, Volatile, or Volatile + Non Volatile. Use the spacebar to toggle between the options.

Range Non Volatile, Volatile + Non Volatile

Field Description · Default Non Volatile

Page 17 of the Panasonic 470 user manual — Port mirroring
Page 17 · click to enlarge
Page 17

This field allows you to determine whether the configuration information received from non-volatile or dynamic memory (depending on what is selected in the Display Messages From field) is complete. Use the spacebar to toggle between the options.

Clear Messages From This field allows you to clear the information messages from dynamic or non-volatile memory or both. If you clear dynamic messages, existing non-volatile messages are copied into dynamic memory. After a system reset, all existing non-volatile messages are copied to dynamic memory. Use the spacebar to toggle between the options.

Range None, Non Volatile, Volatile + Non Volatile

Port mirroring

You can designate one of your switch ports to monitor traffic on any two specified switch ports (port-based) or to monitor traffic to or from any two specified addresses that the switch has learned (address-based).

The following sections provide sample configurations using the Console Interface for both monitoring modes available with the port mirroring feature:

  • Port-based mirroring
  • Address-based mirroring

A sample Port Mirroring Configuration screen accompanies each network configuration example. Note that the examples do not show all of the screen prompts that precede some actions.

For example, when you configure a switch for port mirroring or when you modify an existing port mirroring configuration, the new configuration does not take effect until you respond [Yes] to the following screen prompt:

Panasonic 470 — Port mirroring diagram (page 17)
Fig. 3 · Port mirroring
Show 6 more labels / short text on this page
Port mirroring 17 · Field Description · Display configuration complete? · Default No · Range No, Yes · Default None
Page 18 of the Panasonic 470 user manual — Port-based mirroring configuration
Page 18 · click to enlarge
Page 18

18 Chapter 1 Network monitoring

Port-based mirroring configuration

Figure 2 "Port-based mirroring configuration example" (page 18) shows an example of a port-based mirroring configuration where port 23 is designated as the monitor port for ports 24 and 25 of Switch S1. Although this example shows ports 24 and 25 monitored by the monitor port (port 23), any of the trunk members of T1 and T2 can also be monitored.

In this example, port X and port Y are members of Trunk T1 and Trunk T2. Port X and port Y are not required to always be members of Trunk T1 and Trunk T2.

Figure 2 "Port-based mirroring configuration example" (page 18) shows the Port Mirroring Configuration screen setup for this example.

Figure 2 Port-based mirroring configuration example

Panasonic 470 — Port-based mirroring configuration diagram (page 18)
Fig. 4 · Port-based mirroring configuration

In the configuration example shown in Figure 2 "Port-based mirroring configuration example" (page 18), the designated monitor port (port 23) can be set to monitor traffic in any of the following modes:

  • Monitor all traffic received by port X.
  • Monitor all traffic transmitted by port X.
  • Monitor all traffic received and transmitted by port X.
Page 19 of the Panasonic 470 user manual — Address-based mirroring configuration
Page 19 · click to enlarge
Page 19
  • Monitor all traffic received by port X or transmitted by port Y.
  • Monitor all traffic received by port X (destined to port Y) and then transmitted by port Y.
  • Monitor all traffic received/transmitted by port X and transmitted/received by port Y (conversations between port X and port Y).

As shown in the Port Mirroring Configuration screen example (Figure 3 "Port Mirroring Configuration port-based screen example" (page 19)), port 23 is designated as the Monitor Port for ports 24 and 25 in Switch S1.

The Monitoring Mode field [ - > Port X or Port Y - > ] indicates that all traffic received by port X or all traffic transmitted by port Y is currently being monitored by the StackProbe attached to Monitor Port 23.

The screen data displayed at the bottom of the screen shows the currently active port mirroring configuration.

Figure 3 Port Mirroring Configuration port-based screen example

Panasonic 470 — Address-based mirroring configuration diagram (page 19)
Fig. 5 · Address-based mirroring configuration

Address-based mirroring configuration

Figure 4 "Address-based mirroring configuration example" (page 20) shows an example of an address-based mirroring configuration where port 23, the designated monitor port for Switch S1, is monitoring traffic occurring between address A and address B.

Port mirroring 19

Page 20 of the Panasonic 470 user manual — Figure 4 Address-based mirroring configuration example
Page 20 · click to enlarge
Page 20

20 Chapter 1 Network monitoring

Figure 4 Address-based mirroring configuration example

Panasonic 470 — Figure 4 Address-based mirroring configuration example diagram (page 20)
Fig. 6 · Figure 4 Address-based mirroring configuration examp…

In this configuration, the designated monitor port (port 23) can be set to monitor traffic in any of the following modes:

  • Monitor all traffic transmitted from address A to any address.
  • Monitor all traffic received by address A from any address.
  • Monitor all traffic received by or transmitted by address A.
  • Monitor all traffic transmitted by address A to address B.
  • Monitor all traffic between address A and address B (conversation between the two stations).

Figure 5 "Port Mirroring Configuration address-based screen example" (page 21) shows the Port Mirroring Configuration screen setup for this example.

In this example, port 23 becomes the designated Monitor Port for Switch S1 when you press Enter in response to the [Yes] screen prompt.

Page 21 of the Panasonic 470 user manual — Port mirroring configuration rules
Page 21 · click to enlarge
Page 21

The Monitoring Mode field [ Address A - > Address B ] indicates that all traffic transmitted by address A to address B is monitored by the StackProbe attached to Monitor Port 23.

Figure 5 Port Mirroring Configuration address-based screen example

Panasonic 470 — Port mirroring configuration rules diagram (page 21)
Fig. 7 · Port mirroring configuration rules

Port mirroring configuration rules

The following configuration rules apply to any port mirroring configuration:

  • You cannot configure a monitor port as a trunk member or IGMP member.
  • A monitor port cannot be used for normal switch functions.
  • When you configure a port as a monitor port, the port is automatically disabled from participating in the spanning tree. When you reconfigure the port as a standard switch port (no longer a monitor port), the port is enabled for spanning tree participation.
  • When you create a port-based port mirroring configuration, be sure that the monitor port and both of the mirrored ports, port X and port Y, have the same configuration. Use the VLAN Configuration screen to configure the VLAN EAPOL.

Port mirroring 21

Page 22 of the Panasonic 470 user manual — Port Mirroring Configuration screen
Page 22 · click to enlarge
Page 22

22 Chapter 1 Network monitoring

  • VLAN configuration settings for any ports configured for port-based mirroring cannot be changed. Use the Port Mirroring Configuration screen to disable port mirroring (or reconfigure the port mirroring ports), then change the VLAN configuration settings.
  • For port-based monitoring of traffic, use one of the following modes for monitoring broadcast, IP Multicast, or unknown DA frames:

— Monitor all traffic received by port X.

— Monitor all traffic transmitted by port X.

— Monitor all traffic received and transmitted by port X.

Appendix "Quick steps for port mirroring" (page 123) also provides configuration flowcharts that can help you use this feature.

Port Mirroring Configuration screen

The Port Mirroring Configuration screen allows you to configure a specific switch port to monitor up to two specified ports or two MAC addresses. You can specify port-based monitoring or address-based monitoring.

Figure 6 "Port Mirror Configuration screen" (page 22) shows an example of a Port Mirroring Configuration screen.

To open the Port Mirroring Configuration screen:

è Choose Port Mirroring Configuration (or type i) from the Switch Configuration Menu screen.

Figure 6 Port Mirror Configuration screen

Panasonic 470 — Port Mirroring Configuration screen diagram (page 22)
Fig. 8 · Port Mirroring Configuration screen
Page 23 of the Panasonic 470 user manual — Table 2 Port Mirroring Configuration screen fields
Page 23 · click to enlarge
Page 23

Table 2 "Port Mirroring Configuration screen fields" (page 23) describes the Port Mirroring Configuration screen fields.

Table 2 Port Mirroring Configuration screen fields

Allows a user to select any one of six port-based monitoring modes or any one of five address-based monitoring modes (see Table 3 "Monitoring modes" (page 24)). Selecting any one of the six port-based modes activates the port X and port Y screen fields, where a user can choose up to two ports to monitor. Selecting any one of the five address-based modes activates the Address A and Address B screen fields, where a user can specify MAC addresses to monitor.

Default ValueDisabled
RangeSee Table 3 "Monitoring modes" (page 24)

Indicates the port number (of the specified unit) that is designated as the monitor port.

Default ValueZero-length string
Range1 to 8 or 1 to 26 (depending on model type)

Indicates one of the ports (of the specified unit) that is monitored by the designated port monitor when one of the port-based monitoring modes is selected.

This port is monitored according to the value of Port X in the Monitoring Mode field (see Table 3 "Monitoring modes" (page 24)).

Default ValueZero-length string
Range1 to 8 or 1 to 26 (depending on model type)

Indicates one of the ports (of the specified unit) that is monitored by the designated port monitor when one of the port-based monitoring modes is selected. When installed as a stand-alone switch, the screen does not display the (Unit/) field designation. This port is monitored according to the value of Port Y in the Monitoring Mode field (see Table 3 "Monitoring modes" (page 24)).

Default ValueZero-length string
Range1 to 8 or 1 to 26 (depending on model type)
Show 6 more labels / short text on this page
Port mirroring 23 · Field Description · Monitoring Mode · Monitor Unit/Port · Unit/Port X · Unit/Port Y
Page 24 of the Panasonic 470 user manual — Table 3 Monitoring modes
Page 24 · click to enlarge
Page 24

24 Chapter 1 Network monitoring

Indicates the MAC addresses that is monitored by the designated port monitor when one of the address-based monitoring modes is selected. This port is monitored according to the value of Address A in the selected Monitoring Mode field (see Table 3 "Monitoring modes" (page 24)).

Default Value00-00-00-00-00-00 (no MAC address assigned)
Range00-00-00-00-00-00 to FF-FF-FF-FF-FF-FF

Indicates the MAC addresses that is monitored by the designated port monitor when one of the address-based monitoring modes is selected. This port is monitored according to the value of Address B in the selected Monitoring Mode field (see Table 3 "Monitoring modes" (page 24)).

Default Value00-00-00-00-00-00 (no MAC address assigned)
Range00-00-00-00-00-00 to FF-FF-FF-FF-FF-FF

Table 3 "Monitoring modes" (page 24) describes the various monitoring modes available from the Port Mirroring Configuration screen.

Table 3 Monitoring modes

Port-based:

Disabled Default value for this feature.

-> Port X Monitor all traffic received by Port X.

Port X -> Monitor all traffic transmitted by Port X.

Port X Monitor all traffic received and transmitted by Port X.

-> Port X or Port Y -> Monitor all traffic received by Port X or transmitted by Port Y.

-> Port X and Port Y -> Monitor all traffic received by Port X (destined to Port Y) and then transmitted by Port Y.

Show 4 more labels / short text on this page
Field Description · Address A · Address B · Field Description
Page 25 of the Panasonic 470 user manual — Port Statistics screen
Page 25 · click to enlarge
Page 25

Port Statistics screen 25

Port X and Port Y Monitor all traffic received/transmitted by Port X and received/transmitted by Port Y.

Address-based:

Disabled Default value for this feature.

Address A -> any Address Monitor all traffic transmitted from Address A to any address.

any Address -> Address A Monitor all traffic received by Address A from any address.

Address A Monitor all traffic received by or transmitted by Address A.

Address A -> Address B Monitor all traffic transmitted by Address A to Address B.

Address A Address B Monitor all traffic between Address A and Address B (conversation between the two stations).

Port Statistics screen

The Port Statistics screen, as displayed in Figure 7 "Port statistics screen" (page 26), allows you to view detailed information about any switch or port in a configuration. The screen is divided into two sections (Received and Transmitted) so that you can compare and evaluate throughput or other port parameters. All screen data is updated approximately every 2 seconds.

You can use the Port Statistics screen to clear (reset to zero) port counters for a specific switch or port. Alternatively, you can use the Clear All Port Statistics option to clear port counters for all switches or ports.

To open the Port Statistics screen:

Choose Display Port Statistics (or type d) from the Switch Configuration Menu screen.

Field Description

Page 26 of the Panasonic 470 user manual — Figure 7 Port statistics screen
Page 26 · click to enlarge
Page 26

26 Chapter 1 Network monitoring

Figure 7 Port statistics screen

Panasonic 470 — Figure 7 Port statistics screen diagram (page 26)
Fig. 9 · Figure 7 Port statistics screen

Table 4 "Port Statistics screen fields" (page 26) describes the Port Statistics screen fields.

Table 4 Port Statistics screen fields

Port Allows you to select the number of the port you want to view or reset to zero.

To view another port, enter its port number and press Enter, or press the spacebar on your keyboard to toggle the port numbers.

Packets Received column: Indicates the total number of packets received on this port, including bad packets, broadcast packets, and multicast packets.

Transmitted column: Indicates the total number of packets transmitted successfully on this port, including broadcast packets and multicast packets.

Multicasts Received column: Indicates the total number of good multicast packets received on this port, excluding broadcast packets.

Transmitted column: Indicates the total number of multicast packets transmitted successfully on this port, excluding broadcast packets.

Field Description

Page 27 of the Panasonic 470 user manual — Figure 7 Port statistics screen
Page 27 · click to enlarge
Page 27

Port Statistics screen 27

Broadcasts Received column: Indicates the total number of good broadcast packets received on this port.

Transmitted column: Indicates the total number of broadcast packets transmitted successfully on this port.

Total Octets Received column: Indicates the total number of octets of data (including data in bad packets) received on this port, excluding framing bits but including FCS octets.

Transmitted column: Indicates the total number of octets of data transmitted successfully on this port, including FCS octets.

Lost Packets Received column: Indicates the total number of packets lost (discarded) when the capacity of the port receive buffer was exceeded.

Transmitted column: Indicates the total number of packets lost (discarded) when the capacity of the port transmit buffer was exceeded.

Packets 64 bytes Received column: Indicates the total number of 64-byte packets received on this port.

Transmitted column: Indicates the total number of 64-byte packets transmitted successfully on this port.

65-127 bytes Received column: Indicates the total number of 65-byte to 127-byte packets received on this port.

Transmitted column: Indicates the total number of 65-byte to 127-byte packets transmitted successfully on this port.

128-255 bytes Received column: Indicates the total number of 128-byte to 255-byte packets received on this port.

Transmitted column: Indicates the total number of 128-byte to 255-byte packets transmitted successfully on this port.

256-511 bytes Received column: Indicates the total number of 256-byte to 511-byte packets received on this port.

Transmitted column: Indicates the total number of 256-byte to 511-byte packets transmitted successfully on this port.

Field Description

Page 28 of the Panasonic 470 user manual — Figure 7 Port statistics screen
Page 28 · click to enlarge
Page 28

28 Chapter 1 Network monitoring

512-1023 bytes Received column: Indicates the total number of 512-byte to 1023-byte packets received on this port.

Transmitted column: Indicates the total number of 512-byte to 1023-byte packets transmitted successfully on this port.

1024-1518 bytes Received column: Indicates the total number of 1024-byte to 1518-byte packets received on this port.

Transmitted column: Indicates the total number of 1024-byte to 1518-byte packets transmitted successfully on this port.

Frame Errors Indicates the total number of valid-size packets received but discarded because of CRC errors and improper framing.

Undersized Packets Indicates the total number of packets received on this port with fewer than 64 bytes and with proper CRC and framing (also known as short frames or runts).

Oversized Packets Indicates the total number of packets received on this port with more than 1518 bytes and with proper CRC and framing (also known as oversized frames).

Filtered Packets Indicates the number of packets filtered (not forwarded) by this port.

Flooded Packets Indicates the total number of packets flooded (forwarded) through this port because the destination address was not in the address database.

FCS Errors Indicates the total number of valid-size packets received with proper framing but discarded because of cyclic redundancy check (CRC) errors.

Collisions Indicates the total number of collisions detected on this port.

Single Collisions Indicates the total number of packets transmitted successfully on this port after a single collision.

Multiple Collisions Indicates the total number of packets transmitted successfully on this port after more than one collision.

Excessive Collisions Indicates the total number of packets lost on this port due to excessive collisions.

Deferred Packets Indicates the total number of frames delayed on the first transmission attempt, but that never incurred a collision.

Late Collisions Indicates the total number of packet collisions that occurred after a total length of time that exceeded 512 bit-times of packet transmission.

Field Description

Page 29 of the Panasonic 470 user manual — Figure 7 Port statistics screen
Page 29 · click to enlarge
Page 29

Port Statistics screen 29

The following field values appear only when the port selected in the Unit/Port field is configured with a GBIC.

Pause Frames Transmitted column: Indicates the total number of pause frames transmitted on this port. Pause frames cause the transmitting port to temporarily suspend the transmission of packets when the frame buffer of the receiving port is full (Gigabit ports only).

Received column: Indicates the total number of pause frames received on this port. Pause frames cause the transmitting port to temporarily suspend the transmission of packets when the frame buffer of the receiving port is full (Gigabit ports only).

Field Description

Page 30 of the Panasonic 470 user manual — Figure 7 Port statistics screen
Page 30 · click to enlarge
Page 30

30 Chapter 1 Network monitoring

Page 31 of the Panasonic 470 user manual — Setting the system event log
Page 31 · click to enlarge
Page 31

Chapter 2 Configuring network monitoring using CLI

You can configure network monitoring features and display switch statistics using the CLI. This chapter contains information on the following topics:

  • "Setting the system event log" (page 31)
  • "Enabling remote logging" (page 35)
  • "Using port mirroring" (page 39)
  • "Displaying port statistics" (page 41)

Setting the system event log

You can set the system event log to log different levels of events. This section covers:

  • "show logging" (page 31)
  • "logging" (page 32)
  • "no logging" (page 33)
  • "set logging" (page 33)
  • "no set logging" (page 34)
  • "default logging" (page 34)
  • "default set logging" (page 34)
  • "clear logging command" (page 34)

show logging The show logging command displays the current contents of the system event log. The default value displays all levels in chronological order. The syntax for the show logging command is:

show logging [config | critical | serious | informational]

The show logging command is in the privExec command mode.

Page 32 of the Panasonic 470 user manual — Figure 8 show logging sort-reverse command output
Page 32 · click to enlarge
Page 32

32 Chapter 2 Configuring network monitoring using CLI

Table 5 "show logging command parameters and variables" (page 32) describes the parameters and variables for show logging command.

Table 5 show logging command parameters and variables

config Displays configuration log messages. (This command parameter is only available with the Ethernet Switch 470-24T.)

critical Displays critical log messages.

serious Displays serious log messages.

informational Displays informational log messages.

Figure 8 "show logging sort-reverse command output" (page 32) shows the output of the show logging sort-reverse command.

Figure 8 show logging sort-reverse command output

Panasonic 470 — Figure 8 show logging sort-reverse command output diagram (page 32)
Fig. 10 · Figure 8 show logging sort-reverse command output

logging The logging command configures the system settings for the system event log of the Ethernet Switch 470-24T. The syntax for the logging command is:

logging [enable | disable] [level critical | serious | informational] [nv-level critical | serious | informational | none]

The logging command is in the config command mode.

Parameters and variables · Description

Page 33 of the Panasonic 470 user manual — Table 6 logging command parameters and variables
Page 33 · click to enlarge
Page 33

Setting the system event log 33

Table 6 "logging command parameters and variables" (page 33) describes the parameters and variables for the logging command.

Table 6 logging command parameters and variables

Parameters and variables Description

enable | disable Enables or disables the event log (default is enabled).

level critical | serious | informational

Specifies the level of logging stored in DRAM.

nv-level critical | serious | informational | none

Specifies the level of logging stored in non-volatile memory (NVRAM).

no logging The no logging command disables the system event log on the Ethernet Switch 470-24T. The syntax for the no logging command is:

The no logging command is in the config command mode.

The no logging command has no parameters or variables.

set logging The set logging command configures the system settings of the system event log for the Ethernet Switch 470-48T or the Ethernet Switch 460-24T. The syntax for the set logging command is:

set logging [enable | disable] [level critical | serious | informational] [nv-level critical | serious | informational | none]

The set logging command is in the config command mode.

Table 7 "set logging command parameters and variables" (page 33) describes the parameters and variables for the set logging command.

Table 7 set logging command parameters and variables

Parameters and variables Description

enable | disable Enables or disables the event log (default is enabled).

no logging

Page 34 of the Panasonic 470 user manual — Table 6 logging command parameters and variables
Page 34 · click to enlarge
Page 34

34 Chapter 2 Configuring network monitoring using CLI

Parameters and variables Description

level critical | serious | informational

Specifies the level of logging stored in DRAM.

nv-level critical | serious | informational | none

Specifies the level of logging stored in NVRAM.

no set logging The no set logging command disables the system event log for the Ethernet Switch 470-48T or the Ethernet Switch 460-24T. The syntax for the no set logging command is:

The no set logging command is in the config command mode.

The no set logging command has no parameters or variables.

default logging The default logging command configures the system settings as the factory default settings for the system event log on the Ethernet Switch 470-24T. The syntax for the default logging command is:

The default logging command is in the config command mode.

The default logging command has no parameters or variables.

default set logging The default set logging command configures the system settings as the factory default settings for the system event log on the Ethernet Switch 470-48T or the Ethernet Switch 460-24T. The syntax for the default set logging command is:

The default set logging command is in the config command mode.

The default set logging command has no parameters or variables.

clear logging command The clear logging command clears all log messages in DRAM. The syntax for the clear logging command is:

The clear logging command is in the privExec command mode.

Show 4 more labels / short text on this page
no set logging · default logging · default set logging · clear logging [nv]
Page 35 of the Panasonic 470 user manual — show logging
Page 35 · click to enlarge
Page 35

Enabling remote logging 35

Table 8 "clear logging command parameters and values" (page 35) shows the parameters and values for the clear logging command.

Table 8 clear logging command parameters and values

Parameters and values Description

nv Clears all log messages in both DRAM and non-volatile memory (NVRAM).

Enabling remote logging

This feature provides an enhanced level of logging by replicating system messages onto a syslog server. System log messages from several switches can be collected at a central location, which alleviates the network manager querying each switch individually to interrogate the log files. This section covers the following commands:

  • "show logging" (page 35)
  • "logging remote enable command" (page 36)
  • "no logging remote enable command" (page 37)
  • "logging remote address command" (page 37)
  • "no logging remote address command" (page 37)
  • "logging remote level command" (page 38)
  • "no logging remote level command" (page 38)
  • "default logging remote level command" (page 39)

show logging

The show logging command displays the configuration and the current contents of the system event log. The syntax for the show logging command is:

show logging [config] [critical] [informational] [serious] [sort-reverse]

The show logging command is in the privExec command mode.

Page 36 of the Panasonic 470 user manual — logging remote enable command
Page 36 · click to enlarge
Page 36

36 Chapter 2 Configuring network monitoring using CLI

Table 9 "show logging command parameters and variables" (page 36) describes the parameters and variables for the show logging command.

Table 9 show logging command parameters and variables

Parameters and variables Description

config Displays the configuration of event logging.

critical Displays critical log messages.

informational Displays informational log messages.

serious Displays serious log messages.

sort-reverse Displays log messages in reverse chronological order (beginning with most recent).

Figure 9 "show logging config command output" (page 36) shows the output of the show logging config command.

Figure 9 show logging config command output

Panasonic 470 — logging remote enable command diagram (page 36)
Fig. 11 · logging remote enable command

logging remote enable command

The logging remote enable command enables logging syslog messages to a remote server. The syntax for the remote logging enable command is:

The logging remote enable command is in the config command mode.

The logging remote enable command has no parameters or variables.

logging remote enable

Page 37 of the Panasonic 470 user manual — no logging remote address command
Page 37 · click to enlarge
Page 37

Enabling remote logging 37

no logging remote enable command

The no logging remote enable command disables sending syslog messages to a remote server. The syntax for the no logging remote enable command is:

no logging remote enable

The no remote logging enable command is in the config command mode.

The no remote logging enable command has no parameters or variables.

logging remote address command

The logging remote address command sets the remote server for receiving the syslog messages; you enter the IP address of the server you want. The syntax for the logging remote address command is:

logging remote address <A.B.C.D>

The logging remote address command is in the config command mode.

Table 10 "logging remote address command parameters and variables" (page 37) describes the parameters and variables for the logging remote address command.

Table 10 logging remote address command parameters and variables

Parameters and variables Description

Specifies the IP address of the remote server in dotted-decimal notation.

The default address is 0.0.0.0.

no logging remote address command

The no logging remote address command clears the IP address of the remote server. The syntax for the no logging remote address command is:

no logging remote address

The no logging remote address command is in the config command mode.

Page 38 of the Panasonic 470 user manual — no logging remote level command
Page 38 · click to enlarge
Page 38

38 Chapter 2 Configuring network monitoring using CLI

The no logging remote address command has no parameters or variables.

logging remote level command

The logging remote level command sets the severity level of the logs you send to the remote server. The syntax for the logging remote level command is:

logging remote level {critical | informational | serious}

The logging remote level command is in the config command mode.

Table 11 "logging remote level command parameters and variables" (page 38) describes the parameters and variables for the logging remote level command.

Table 11 logging remote level command parameters and variables

Parameters and variables Description

{critical | serious | informational}

Specifies the severity level of the log messages sent to the remote server:

  • critical
  • informational
  • serious

There is no default value for this command.

no logging remote level command

The no logging remote level command removes any severity level of the log messages that you send to the remote server; it reverts to None. The syntax for the no logging remote level command is:

no logging remote level

The no logging remote level command is in the config command mode.

The no logging remote level command has no parameters or variables.

Page 39 of the Panasonic 470 user manual — show port-mirroring command
Page 39 · click to enlarge
Page 39

Using port mirroring 39

default logging remote level command

The default logging remote level command sets the severity level of the logs you send to the remote server to the default value, which is None. The syntax for the default logging remote level command is:

default logging remote level

The default logging remote level command is in the config command mode.

The default logging remote level command has no parameters or variables.

Using port mirroring

You use port mirroring to monitor traffic. This section covers the following commands:

  • "show port-mirroring command" (page 39)
  • "port-mirroring command" (page 40)
  • "no port-mirroring command" (page 41)

show port-mirroring command

The show port-mirroring command displays the port mirroring configuration. The syntax for the show port-mirroring command is:

The show port-mirroring command is in the privExec command mode.

The show port-mirroring command has no parameters or variables.

Figure 10 "show port-mirroring command output" (page 39) displays sample output from the show port-mirroring command.

Figure 10 show port-mirroring command output

Panasonic 470 — show port-mirroring command diagram (page 39)
Fig. 12 · show port-mirroring command

show port-mirroring

Page 40 of the Panasonic 470 user manual — port-mirroring command
Page 40 · click to enlarge
Page 40

40 Chapter 2 Configuring network monitoring using CLI

port-mirroring command

The port-mirroring command sets the port mirroring configuration. The syntax of the port-mirroring command is:

{disable | Xrx monitor-port <portlist> mirror-port-X <portlist> | Xtx monitor-port <portlist> mirror-port-X <portlist> | XrxOrXtx monitor-port <portlist> mirror-port-X <portlist> mirror-port-Y <portlist> | XrxOrYtx monitor-port <portlist> mirror-port-X <portlist> mirror-port-Y <portlist> | XrxYtx monitor-port <portlist> mirror-port-X <portlist> mirror-port-Y <portlist> | XrxYtxOrYrxXtx monitor-port <portlist> mirror-port-X <portlist> mirror-port-Y <portlist> | Asrc monitor-port <portlist> mirror-MAC-A <macaddr> | Adst monitor-port <portlist> mirror-MAC-A <macaddr> | AsrcOrAdst monitor-port <portlist> mirror-MAC-A <macaddr> | AsrcBdst monitor-port <portlist> mirror-MAC-A <macaddr> mirror-MAC-B <macaddr> | AsrcBdstOrBsrcAdst monitor-port <portlist> mirror-MAC-A <macaddr> mirror-MAC-B <macaddr>}

The port-mirroring command is in the config command mode.

Table 12 "port-mirroring command parameters and variables" (page 40) describes the parameters and variables for the port-mirroring command.

Table 12 port-mirroring command parameters and variables

Parameters and variables Description

disable Disables port mirroring.

monitor-port Specifies the monitor port.

mirror-port-X Specifies the mirroring port X.

mirror-port-Y Specifies the mirroring port Y.

mirror-MAC-A Specifies the mirroring MAC address A.

mirror-MAC-B Specifies the mirroring MAC address B.

portlist Enter the port number.

Xrx Mirror packets received on port X.

port-mirroring mode

Page 41 of the Panasonic 470 user manual — Displaying port statistics
Page 41 · click to enlarge
Page 41

Displaying port statistics 41

Parameters and variables Description

Xtx Mirror packets transmitted on port X.

XrxOrXtx Mirror packets received or transmitted on port X.

XrxYtx Mirror packets received on port X and transmitted on port Y.

XrxYtxOrXtxYrx Mirror packets received on port X and transmitted on port Y or packets received on port Y and transmitted on port X.

macaddr Enter the MAC address in format H.H.H.

Asrc Mirror packets with source MAC address A.

Adst Mirror packets with destination MAC address A.

AsrcOrAdst Mirror packets with source or destination MAC address A.

AsrcBdst Mirror packets with source MAC address A and destination MAC address B.

AsrcBdstOrBsrcAdst Mirror packets with source MAC address A and destination MAC address B or packets with source MAC address B and destination MAC address A.

no port-mirroring command

The no port-mirroring command disables port mirroring. The syntax of the no port-mirroring command is:

The no port-mirroring command is in the config command mode.

The no port-mirroring command has no parameters or variables.

Displaying port statistics

You can display the statistics for a port for both received and transmitted traffic. This section covers:

  • "show port-statistics command" (page 42)
  • "clear-stats command" (page 43)

no port-mirroring

Page 42 of the Panasonic 470 user manual — show port-statistics command
Page 42 · click to enlarge
Page 42

42 Chapter 2 Configuring network monitoring using CLI

show port-statistics command

The show port-statistics command displays the statistics for the port on both received and transmitted traffic. The syntax for the show port-statistics command is:

show port-statistics [port <portlist>]

The show port-statistics command is in the config-if command mode.

Table 13 "show port-statistics command parameters and variables" (page 42) describes the parameters and variables for the show port-statistics command.

Table 13 show port-statistics command parameters and variables

Parameters and variables Description

port <portlist> Specifies the port numbers for which to display statistics.

Figure 11 "show port-statistics command output" (page 43) displays sample output from the show port-statistics command.

Page 43 of the Panasonic 470 user manual — clear-stats command
Page 43 · click to enlarge
Page 43

Displaying port statistics 43

Figure 11 show port-statistics command output

Panasonic 470 — clear-stats command diagram (page 43)
Fig. 13 · clear-stats command

clear-stats command

The clear-stats command clears all statistical information for the specified port. All counters are set to zero (0). The syntax for the clear-stats command is:

The clear-stats command is in the config-if command mode.

clear-stats [port <portlist>]

Page 44 of the Panasonic 470 user manual — Table 14 clear-stats command parameters and variables
Page 44 · click to enlarge
Page 44

44 Chapter 2 Configuring network monitoring using CLI

Table 14 "clear-stats command parameters and variables" (page 44) describes the parameters and variables for the clear-stats command.

Table 14 clear-stats command parameters and variables

Parameters and variables Description

port <portlist> Specifies the port numbers to clear of statistical information; enter the port numbers.

Page 45 of the Panasonic 470 user manual — Step Action
Page 45 · click to enlarge
Page 45

Chapter 3 Configuring network monitoring using Device Manager

You can use the Device Manager to configure system logging and to display chassis and port statistics for the Ethernet Switches 460 and 470.

This section contains the following topics:

  • "System Log Settings tab" (page 45)
  • "Remote System Log tab" (page 47)
  • "Graphing chassis statistics" (page 49)
  • "Graphing port statistics" (page 56)

System Log Settings tab

To view System Log Settings information:

Step Action

1 From the Device Manager menu bar, select Edit > Diagnostics > System Log.

The SysLog dialog box opens with the System Log Settings tab displayed. (Figure 12 "System Log Settings tab" (page 46)).

Page 46 of the Panasonic 470 user manual — —End—
Page 46 · click to enlarge
Page 46

46 Chapter 3 Configuring network monitoring using Device Manager

Figure 12 System Log Settings tab

Panasonic 470 — Figure 12 System Log Settings tab diagram (page 46)
Fig. 14 · Figure 12 System Log Settings tab

—End—

Table 15 "System Log Settings tab items" (page 46) describes the System Log Settings tab items.

Table 15 System Log Settings tab items

Operation Specifies the storing or discarding of generated log messages. Specifying On causes log messages to be stored in the log message buffer facility. Specifying Off discontinues the storing of log messages. Previously collected log messages remain stored in the buffer facility until they are manually cleared or the system is reset. Resets do not clear log messages that have been saved in non-volatile storage.

BufferFullAction Specifies overwriting of previous log messages, where messages are overwritten based on FIFO, or specifies that no more messages be saved until the setting is changed to overwrite.

This applies only to messages that are maintained in volatile storage. Messages saved in non-volatile storage are never overwritten, and must be cleared manually.

Items Description

Page 47 of the Panasonic 470 user manual — Remote System Log tab
Page 47 · click to enlarge
Page 47

Remote System Log tab 47

Volatile CurrSize The current number of log messages in the volatile portion of the system log message facility. Messages that are classified as volatile are lost upon system re-initialization.

Volatile Save Targets Specifies the type of log messages to be saved in the log message buffer facilities. Messages are classified based on their type:

  • Critical - Specifies that only critical messages be saved to volatile storage.
  • Critical/Serious - Specifies that both critical and serious messages be saved to volatile storage.
  • Critical/Serious/Informational - Causes all log messages be saved when the log message is entered into the system.
  • None - Specifies that no log messages will be stored in volatile memory.

Non-Volatile CurrSize The current number of log messages in the non-volatile portion of the system log message facility. Messages that are classified as non-volatile are not lost upon system re-initialization.

Specifies the type of log messages to be saved in the log message buffer facilities. Messages are classified based on their type:

  • Critical - Specifies that only critical messages be saved to non-volatile storage.
  • Critical/Serious - Specifies that both critical and serious messages be saved to non-volatile storage.
  • None - Specifies that no log messages will be stored in non-volatile memory.

Specifies the type of log messages to clear.

Remote System Log tab

To view Remote System Log information:

The Remote System Log tab opens.

Items Description · Non-Volatile Save Targets · Action ClearMessag eBuffers

Page 48 of the Panasonic 470 user manual — —End—
Page 48 · click to enlarge
Page 48

48 Chapter 3 Configuring network monitoring using Device Manager

Step Action

1 From the Device Manager menu bar, select Edit > Diagnostics > System Log.

The SysLog dialog box opens with the System Log Settings tab displayed.

2 Click the Remote System Log tab.

The Remote System Log tab opens (Figure 13 "Remote System Log tab" (page 48)).

Figure 13 Remote System Log tab

Panasonic 470 — Step Action diagram (page 48)
Fig. 15 · Step Action

—End—

Table 16 "Remote System Log tab items" (page 48) describes the Remote System Log tab items.

Table 16 Remote System Log tab items

Address The IP address where log messages are sent using the remote syslog facility.

Enabled Specifies that the remote logging feature is enabled.

SaveTargets Specifies the type of log messages to be sent to a remote syslog server when they occur. Messages are classified based on their type:

  • Critical - Specifies that only critical messages are sent to the remote syslog server.
  • Critical/Serious - Specifies that both critical and serious messages are sent to the remote syslog server.

Items Description

Page 49 of the Panasonic 470 user manual — Step Action
Page 49 · click to enlarge
Page 49

Graphing chassis statistics 49

  • Critical/Serious/Informational - Causes all log messages are sent to the remote syslog server
  • None - Specifies that no log messages are sent to the remote syslog server.

Graphing chassis statistics

To graph chassis statistics:

Step Action

1 Select the chassis.

2 Do one of the following:

  • From the shortcut menu, choose Graph.
  • From Device Manager main menu, choose Graph > Chassis.
  • On the toolbar, click Graph.

—End—

The following describe the Graph Chassis dialog box tabs with descriptions of the statistics on each tab.

  • "IP tab" (page 49)
  • "ICMP In tab" (page 53)
  • "ICMP Out tab" (page 54)

Six columns provide the statistics for the counters that are listed on the tab.

IP tab

The IP tab shows IP information for the chassis.

To open the IP tab:

Step Action

1 From the Main Menu, choose Graph > Chassis.

Items Description

Page 50 of the Panasonic 470 user manual — Figure 14 Graph Chassis dialog box -- Chassis SNMP tab
Page 50 · click to enlarge
Page 50

50 Chapter 3 Configuring network monitoring using Device Manager

The Graph Chassis dialog box opens with the SNMP tab displayed (Figure 14 "Graph Chassis dialog box -- Chassis SNMP tab" (page 50)).

Figure 14 Graph Chassis dialog box -- Chassis SNMP tab

Panasonic 470 — Figure 14 Graph Chassis dialog box -- Chassis SNMP tab diagram (page 50)
Fig. 16 · Figure 14 Graph Chassis dialog box -- Chassis SNMP t…

2 Click the IP tab.

The IP tab opens (Figure 15 "Graph Chassis dialog box -- IP tab" (page 51)).

Page 51 of the Panasonic 470 user manual — —End—
Page 51 · click to enlarge
Page 51

Graphing chassis statistics 51

Figure 15 Graph Chassis dialog box -- IP tab

Panasonic 470 — Figure 15 Graph Chassis dialog box -- IP tab diagram (page 51)
Fig. 17 · Figure 15 Graph Chassis dialog box -- IP tab

—End—

Table 17 "Chassis IP tab fields" (page 51) describes the Chassis IP tab fields.

Table 17 Chassis IP tab fields

InReceives The total number of input datagrams received from interfaces, including those received in error.

InHdrErrors The number of input datagrams discarded due to errors in their IP headers, including bad checksums, version number mismatch, other format errors, time-to-live exceeded, errors discovered in processing their IP options.

InAddrErrors The number of input datagrams discarded because the IP address in the IP header destination field was not a valid address. This count includes invalid addresses (for example, 0.0.0.0) and addresses of unsupported Classes (for example, Class E). For addresses that are not IP Gateways and therefore do not forward datagrams, this counter includes datagrams discarded because the destination address was not a local address.

Field Description

Page 52 of the Panasonic 470 user manual — Figure 15 Graph Chassis dialog box -- IP tab
Page 52 · click to enlarge
Page 52

52 Chapter 3 Configuring network monitoring using Device Manager

ForwDatagrams The number of input datagrams for which this entity was not their final IP destination, as a result of which an attempt was made to find a route to forward them to that final destination. For addresses that do not act as IP Gateways, this counter includes only those packets that are Source-Routed by way of this address and have successful Source-Route option processing.

InUnknownProtos The number of locally addressed datagrams received successfully but discarded because of an unknown or unsupported protocol.

InDiscards The number of input IP datagrams for which no problems were encountered to prevent their continued processing but that were discarded (for example, for lack of buffer space). Note that this counter does not include any datagrams discarded while awaiting reassembly.

InDelivers The total number of input datagrams successfully delivered to IP user-protocols (including ICMP).

OutRequests The total number of IP datagrams that local IP user-protocols (including ICMP) supplied to IP in requests for transmission. Note that this counter does not include any datagrams counted in ipForwDatagrams.

OutDiscards The number of output IP datagrams for which no problem was encountered to prevent their transmission to their destination, but that were discarded (for example, for lack of buffer space). Note that this counter includes datagrams counted in ipForwDatagrams if any such packets met this (discretionary) discard criterion.

OutNoRoutes The number of IP datagrams discarded because no route could be found to transmit them to their destination. Note that this counter includes any packets counted in ipForwDatagrams that meet this no-route criterion. Note that this includes any datagrams a host cannot route because all of its default gateways are down.

FragOKs The number of IP datagrams successfully fragmented at this entity.

FragFails The number of IP datagrams discarded because they needed to be fragmented at this entity but could not be; for example, because their Don’t Fragment flag was set.

Field Description

Page 53 of the Panasonic 470 user manual — Step Action
Page 53 · click to enlarge
Page 53

Graphing chassis statistics 53

FragCreates The number of IP datagram fragments generated as a result of fragmentation at this entity.

ReasmReqds The number of IP fragments received that needed to be reassembled at this entity.

ReasmOKs The number of IP datagrams successfully reassembled.

ReasmFails The number of failures detected by the IP reassembly algorithm (for whatever reason, such as timed out, errors.). Note that this is not necessarily a count of discarded IP fragments because some algorithms (notably the algorithm in RFC 815) can lose track of the number of fragments by combining them as they are received.

ICMP In tab

To open the ICMP In tab:

Step Action

1 From the Main Menu, choose Graph > Chassis.

The Graph Chassis dialog box opens with the SNMP tab displayed (Figure 14 "Graph Chassis dialog box -- Chassis SNMP tab" (page 50)).

2 Click the ICMP In tab.

The ICMP In tab opens (Figure 16 "Graph Chassis dialog box -- ICMP In tab" (page 53)).

Figure 16 Graph Chassis dialog box -- ICMP In tab

Panasonic 470 — Step Action diagram (page 53)
Fig. 18 · Step Action

Field Description

Page 54 of the Panasonic 470 user manual — Step Action
Page 54 · click to enlarge
Page 54

54 Chapter 3 Configuring network monitoring using Device Manager

—End—

Table 18 "ICMP In tab fields" (page 54) describes the ICMP In tab fields.

Table 18 ICMP In tab fields

SrcQuenchs The number of ICMP Source Quench messages received.

Redirects The number of ICMP Redirect messages received.

Echos The number of ICMP Echo (request) messages received.

EchoReps The number of ICMP Echo Reply messages received.

Timestamps The number of ICMP Timestamp (request) messages received.

TimestampReps The number of ICMP Timestamp Reply messages received.

AddrMasks The number of ICMP Address Mask Request messages received.

AddrMaskReps The number of ICMP Address Mask Reply messages received.

ParmProbs The number of ICMP Parameter Problem messages received.

DestUnreachs The number of ICMP Destination Unreachable messages received.

TimeExcds The number of ICMP Time Exceeded messages received.

ICMP Out tab

To open the ICMP Out tab:

Step Action

1 From the Main Menu, choose Graph > Chassis.

The Graph Chassis dialog box opens with the SNMP tab displayed (Figure 14 "Graph Chassis dialog box -- Chassis SNMP tab" (page 50)).

2 Click the ICMP Out tab.

Field Description

Page 55 of the Panasonic 470 user manual — —End—
Page 55 · click to enlarge
Page 55

Graphing chassis statistics 55

The ICMP Out tab opens (Figure 17 "Graph Chassis dialog box -- ICMP Out tab" (page 55)).

Figure 17 Graph Chassis dialog box -- ICMP Out tab

Panasonic 470 — Figure 17 Graph Chassis dialog box -- ICMP Out tab diagram (page 55)
Fig. 19 · Figure 17 Graph Chassis dialog box -- ICMP Out tab

—End—

Table 19 "ICMP Out tab fields" (page 55) describes the ICMP Out tab fields.

Table 19 ICMP Out tab fields

SrcQuenchs The number of ICMP Source Quench messages sent.

Redirects The number of ICMP Redirect messages received. For a host, this object is always zero, because hosts do not send redirects.

Echos The number of ICMP Echo (request) messages sent.

EchoReps The number of ICMP Echo Reply messages sent.

Timestamps The number of ICMP Timestamp (request) messages sent.

TimestampReps The number of ICMP Timestamp Reply messages sent.

AddrMasks The number of ICMP Address Mask Request messages sent.

AddrMaskReps The number of ICMP Address Mask Reply messages sent.

ParmProbs The number of ICMP Parameter Problem messages sent.

Field Description

Page 56 of the Panasonic 470 user manual — —End—
Page 56 · click to enlarge
Page 56

56 Chapter 3 Configuring network monitoring using Device Manager

DestUnreachs The number of ICMP Destination Unreachable messages sent.

TimeExcds The number of ICMP Time Exceeded messages sent.

Graphing port statistics

You can graph statistics for either a single port or multiple ports from the graphPort dialog box. The displays for both single and multiple ports show the identical statistical items. The only difference is that the display for the single windows displays the following values simultaneously, while you select which of the following to display in the multiple port graph dialog box:

  • AbsoluteValue
  • Cumulative
  • Average/sec
  • Minimum/sec
  • Maximum/sec
  • LastVal/sec

The illustrations in this section show graphs for multiple ports.

To open the graphPort dialog box for graphing:

Step Action

1 Select the port or ports you want to graph.

To select multiple ports, [Ctrl] + left-click the ports that you want to configure. A yellow outline appears around the selected ports.

2 Do one of the following:

  • From the Device Manager main menu, choose Graph > Port.
  • From the shortcut menu, choose Graph.
  • On the toolbar, click Graph.

—End—

Field Description

Page 57 of the Panasonic 470 user manual — —End—
Page 57 · click to enlarge
Page 57

Graphing port statistics 57

The graphPort dialog box for a single port or for multiple ports opens with the Interface tab displayed.

Interface tab for graphing ports

The Interface tab shows interface parameters for graphing a port or ports.

To open the Interface tab for graphing:

Step Action

1 Select the port or ports you want to graph.

To select multiple ports, [Ctrl] + left-click the ports that you want to configure. A yellow outline appears around the selected ports.

2 Do one of the following:

  • From the Device Manager main menu, choose Graph > Port.
  • From the shortcut menu, choose Graph.
  • On the toolbar, click Graph.

The Port dialog box for a single port or for multiple ports ( Figure 18 "Interface tab for graphing ports" (page 57)) opens with the Interface tab displayed.

Figure 18 Interface tab for graphing ports

Panasonic 470 — Step Action diagram (page 57)
Fig. 20 · Step Action

—End—

Page 58 of the Panasonic 470 user manual — Table 20 Port Interface tab fields for multiple ports
Page 58 · click to enlarge
Page 58

58 Chapter 3 Configuring network monitoring using Device Manager

Table 20 "Port Interface tab fields for multiple ports" (page 58) describes the Interface tab fields for graphing ports.

Table 20 Port Interface tab fields for multiple ports

InOctets The total number of octets received on the interface, including framing characters.

OutOctets The total number of octets transmitted out of the interface, including framing characters.

InUcastPkts The number of packets delivered by this sublayer to a higher sublayer that were not addressed to a multicast or broadcast address at this sublayer.

OutUcastPkts The number of packets that higher-level protocols requested be transmitted that were not addressed to a multicast address at this sublayer. This total number includes those packets discarded or unsent.

InNUcastPkts The number of packets delivered by this sublayer to a higher (sub)layer that were addressed to a multicast or broadcast address at this sublayer.

OutNUcastPkts The total number of packets that higher-level protocols requested be transmitted, and that were addressed to a multicast or broadcast address at this sublayer, including those that were discarded or not sent.

InDiscards The number of inbound packets that were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet is to free up buffer space.

OutDiscards The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted. One possible reason for discarding such a packet is to free up buffer space.

InErrors For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol.

Field Description

Page 59 of the Panasonic 470 user manual — Step Action
Page 59 · click to enlarge
Page 59

Graphing port statistics 59

OutErrors For packet-oriented interfaces, the number of outbound packets that were not transmitted because of errors. For character-oriented or fixed-length interfaces, the number of outbound transmission units that could not be transmitted because of errors.

InUnknownProtos For packet-oriented interfaces, the number of packets received through the interface that were discarded because of an unknown or unsupported protocol. For character-oriented or fixed-length interfaces that support protocol multiplexing, the number of transmission units received through the interface that were discarded because of an unknown or unsupported protocol. For any interface that does not support protocol multiplexing, this counter is always 0.

Ethernet Errors tab for graphing ports

The port Ethernet Errors tab shows port Ethernet Errors statistics.

To open the Ethernet Errors tab for graphing:

Step Action

1 Select the port or ports you want to graph.

To select multiple ports, [Ctrl] + left-click the ports that you want to configure. A yellow outline appears around the selected ports.

2 Do one of the following:

  • From the Device Manager main menu, choose Graph > Port.
  • From the shortcut menu, choose Graph.
  • On the toolbar, click Graph.

The Port dialog box for a single port or for multiple ports opens with the Interface tab displayed.

3 Click the Ethernet Errors tab.

The Port Ethernet Errors tab (Figure 19 "Graph Port dialog box -- Port Ethernet Errors tab" (page 60)) opens.

Field Description

Page 60 of the Panasonic 470 user manual — —End—
Page 60 · click to enlarge
Page 60

60 Chapter 3 Configuring network monitoring using Device Manager

Figure 19 Graph Port dialog box -- Port Ethernet Errors tab

Panasonic 470 — Figure 19 Graph Port dialog box -- Port Ethernet Errors tab diagram (page 60)
Fig. 21 · Figure 19 Graph Port dialog box -- Port Ethernet Err…

—End—

Table 21 "Ethernet Errors tab fields" (page 60) describes the Port Ethernet Errors tab fields.

Table 21 Ethernet Errors tab fields

AlignmentErrors A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check. The count represented by an instance of this object is incremented when the alignmentError status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions occur are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC.

FCSErrors A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check. The count represented by an instance of this object is incremented when the Frame Check Error status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions occur are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC.

A count of frames for which transmission on a particular interface fails due to an internal MAC sublayer transmit error. A frame is only counted by an instance of this object if it is not counted by the corresponding instance of either the LateCollisions object, the ExcessiveCollisions object, or the CarrierSenseErrors object.

Field Description · InternalMacTransmitErro rs

Page 61 of the Panasonic 470 user manual — Figure 19 Graph Port dialog box -- Port Ethernet Errors tab
Page 61 · click to enlarge
Page 61

Graphing port statistics 61

A count of frames for which reception on a particular interface fails due to an internal MAC sublayer receive error. A frame is only counted by an instance of this object if it is not counted by the corresponding instance of either the FrameTooLongs object, the AlignmentErrors object, or the FCSErrors object.

The precise meaning of the count represented by an instance of this object is implementation specific. In particular, an instance of this object can represent a count of receive errors on a particular interface that are not otherwise counted.

CarrierSenseErrors The number of times that the carrier sense condition was lost or never asserted when attempting to transmit a frame on a particular interface. The count represented by an instance of this object is incremented at most once per transmission attempt, even if the carrier sense condition fluctuates during a transmission attempt.

FrameTooLongs A count of frames received on a particular interface that exceed the maximum permitted frame size. The count represented by an instance of this object is incremented when the frameTooLong status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions occur are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the LLC.

SQETestErrors A count of times that the SQE TEST ERROR message is generated by the PLS sublayer for a particular interface. The SQE TEST ERROR message is defined in section 7.2.2.2.4 of ANSI/IEEE 802.3-1985 and its generation is described in section 7.2.4.6 of the same document.

DeferredTransmissions A count of frames for which the first transmission attempt on a particular interface is delayed because the medium is busy. The count represented by an instance of this object does not include frames involved in collisions.

Field Description · InternalMacReceiveErro rs

Page 62 of the Panasonic 470 user manual — Step Action
Page 62 · click to enlarge
Page 62

62 Chapter 3 Configuring network monitoring using Device Manager

SingleCollisionFrames A count of successfully transmitted frames on a particular interface for which transmission is inhibited by exactly one collision. A frame that is counted by an instance of this object is also counted by the corresponding instance of either the ifOutUcastPkts, ifOutMulticastPkts, or ifOutBroadcastPkts, and is not counted by the corresponding instance of the MultipleCollisionFrames object.

MultipleCollisionFrames A count of successfully transmitted frames on a particular interface for which transmission is inhibited by more than one collision. A frame that is counted by an instance of this object is also counted by the corresponding instance of either the ifOutUcastPkts, ifOutMulticastPkts, or ifOutBroadcastPkts, and is not counted by the corresponding instance of the SingleCollisionFrames object.

LateCollisions The number of times that a collision is detected on a particular interface later than 512 bit-times into the transmission of a packet. Five hundred and twelve bit-times corresponds to 51.2 microseconds on a 10 Mb/s system. A (late) collision included in a count represented by an instance of this object is also considered as a (generic) collision for purposes of other collision-related statistics.

ExcessiveCollisions A count of frames for which transmission on a particular interface fails due to excessive collisions.

Poll Interval Statistics are updated based on the poll interval.

Default10s
RangeNone, 2s, 5s, 10s, 30s, 1m, 5m, 30m 1h

Bridge tab for graphing ports

The Bridge tab displays port frame statistics.

To open the Bridge tab for graphing:

Step Action

1 Select the port or ports you want to graph.

To select multiple ports, [Ctrl] + left-click the ports that you want to configure. A yellow outline appears around the selected ports.

Field Description

Page 63 of the Panasonic 470 user manual — —End—
Page 63 · click to enlarge
Page 63

Graphing port statistics 63

2 Do one of the following:

  • From the Device Manager main menu, choose Graph > Port.
  • From the shortcut menu, choose Graph.
  • On the toolbar, click Graph.

The Port dialog box for a single port or for multiple ports opens with the Interface tab displayed.

3 Click the Bridge tab.

The Bridge tab for graphing ports opens (Figure 20 "Graph Port dialog box -- Bridge tab" (page 63)).

Figure 20 Graph Port dialog box -- Bridge tab

Panasonic 470 — Figure 20 Graph Port dialog box -- Bridge tab diagram (page 63)
Fig. 22 · Figure 20 Graph Port dialog box -- Bridge tab

—End—

Table 22 "Bridge tab fields" (page 63) describes the Bridge tab fields.

Table 22 Bridge tab fields

DelayExceededDiscards Number of frames discarded by the port due to excessive transit delays through the bridge. It is incremented by both transparent and source route bridges.

MtuExceededDiscards Number of frames discarded by the port due to an excessive size. It is incremented by both transparent and source route bridges.

InFrames The number of frames received by this port from its segment.

Field Description

Page 64 of the Panasonic 470 user manual — Figure 20 Graph Port dialog box -- Bridge tab
Page 64 · click to enlarge
Page 64

64 Chapter 3 Configuring network monitoring using Device Manager

OutFrames The number of frames received by this port from its segment.

InDiscards Count of valid frames received that were discarded (filtered) by the Forwarding Process.

Field Description

Page 65 of the Panasonic 470 user manual — Step Action
Page 65 · click to enlarge
Page 65

Chapter 4 Configuring network monitoring using Web-based management

You can configure network monitoring features using Web-based management.

This chapter contains information on the following topics:

  • "Viewing the system log" (page 65)
  • "Configuring port mirroring" (page 67)
  • "Viewing system statistics" (page 71)
  • "Monitoring MLT traffic" (page 81)

Viewing the system log

You can view a display of messages contained in Non-Volatile Memory or Dynamic Random Access Memory (DRAM).

To open the System Log page:

Step Action

1 From the main menu, choose Fault > System Log.

The System Log page opens (Figure 21 "System Log page" (page 66)).

Page 66 of the Panasonic 470 user manual — Figure 21 System Log page
Page 66 · click to enlarge
Page 66

66 Chapter 4 Configuring network monitoring using Web-based management

Figure 21 System Log page

Panasonic 470 — Figure 21 System Log page diagram (page 66)
Fig. 23 · Figure 21 System Log page

Table 23 "System Log page fields" (page 66) describes the fields on the System Log page.

Table 23 System Log page fields

Section Item Range Description

System Log (View By)

Display Unit 1..8 Choose the unit on which to display messages or clear messages.

Display Messag es From

(1) Non Volatile (2) Volatile + Non Volatile

Choose to display messages from Non Volatile Memory or Volatile (DRAM) and Non Volatile memory.

The default setting is Non Volatile.

(1) Volatile (2) Volatile + Non Volatile (3) None

Choose to clear messages from Volatile memory or Volatile and Non Volatile memory.

The default setting is None (do not clear messages).

Clear Messages From

Page 67 of the Panasonic 470 user manual — Step Action
Page 67 · click to enlarge
Page 67

Configuring port mirroring 67

Section Item Range Description

Index The number of the event.

Time Stamp The time, in hundreths of a second, between system initialization and the time the log messages entered the system.

Message Type The type of message. The options are (1) Critical, (2) Serious, and (3) Informational.

Message A character string that identifies the origin of the message and the reason why the message was generated.

2 In the System Log (View By) section do one or more of the following:

  • Choose the number of the unit from which to display messages.
  • Choose to display messages from both volatile and non-volatile memory or from non-volatile memory only.
  • Choose to clear messages from both volatile and non-volatile memory, from non-volatile memory only, or from neither.

3 Click Submit.

The results of your request are displayed in the System Log section (Figure 21 "System Log page" (page 66)).

—End—

Configuring port mirroring

The Ethernet Switches support port mirroring to analyze traffic. You can view existing port mirroring activity, and you can configure a specific switch port to mirror up to two specified ports or two MAC addresses. When you configure port mirroring, you have the option to specify either port-based monitoring or address-based monitoring.

In a stack configuration, you can monitor ports that reside on different units within the stack.

To configure port mirroring:

Step Action

1 From the main menu, choose Application > Port Mirroring.

System Log

Page 68 of the Panasonic 470 user manual — Figure 22 Port Mirroring page
Page 68 · click to enlarge
Page 68

68 Chapter 4 Configuring network monitoring using Web-based management

The Port Mirroring page opens (Figure 22 "Port Mirroring page" (page 68)).

Figure 22 Port Mirroring page

Panasonic 470 — Figure 22 Port Mirroring page diagram (page 68)
Fig. 24 · Figure 22 Port Mirroring page

Table 24 "Port Mirroring page items" (page 68) describes the items on the Port Mirroring page.

Table 24 Port Mirroring page items

Monitoring Mode (1) Disabled (2) --> Port X (3) Port X --> (4) Port X (5) -->Port X or Port Y --> (6) -->Port X and Port Y --> (7) Port X and Port Y (8) Address A --> any Address (9) any Address --> Address A (10) Address A (11) Address A --> Address B (12) Address A Address B

Choose any one of the six port-based monitoring modes or any one of the five address-based monitoring modes.

For more information on selecting one of the six port-based modes that activates the port X and port Y screen fields, where you can choose up to two ports to monitor, see Table 25 "Port-based monitoring modes" (page 70).

For more information on selecting one of the five address-based modes that activates the Address A and Address B screen fields, where you can specify

Item Range Description

Page 69 of the Panasonic 470 user manual — Figure 22 Port Mirroring page
Page 69 · click to enlarge
Page 69

Configuring port mirroring 69

MAC addresses to monitor, see Table 26 "Address-based monitoring modes" (page 71).

The default setting is Disabled. Port-based monitoring

Monitor Port 1..24 Choose the switch port to designate as the monitor port.

Port X 1..24 Choose the first switch port to be monitored by the designated monitor port. This port is monitored according to the value "X" in the Monitoring Mode field.

Port Y 1..24 Choose the second switch port to be monitored by the designated monitor port. This port is monitored according to the value "Y" in the Monitoring Mode field.

Address A XX-XX-XX-XX-XX-XX Type the MAC address to be monitored by the designated monitor port. This address is monitored according to the value "Address A" in the Monitoring Mode field.

Address B XX-XX-XX-XX-XX-XX Type the MAC address to be monitored by the designated monitor port. This address is monitored according to the value "Address B" in the Monitoring Mode field.

2 Type information in the text boxes, or select from a list.

3 Click Submit.

Selecting one of the port-based monitoring modes activates the port X or the port Y screen fields or both, where you can choose up to two ports to monitor.

Item Range Description · Address-based monitoring

Page 70 of the Panasonic 470 user manual — Table 25 Port-based monitoring modes
Page 70 · click to enlarge
Page 70

70 Chapter 4 Configuring network monitoring using Web-based management

Table 25 "Port-based monitoring modes" (page 70) describes the port-based monitoring modes.

Table 25 Port-based monitoring modes

Disabled Choose this option to disable port-based monitoring.

The default setting is Disabled.

--> Port X Choose this option to monitor all traffic received by port X.

Port X --> Choose this option to monitor all traffic transmitted by port X.

Port X Choose this option to monitor all traffic received and transmitted by port X.

--> Port X or Port Y --> Choose this option to monitor all traffic received by port X or transmitted by port Y.

--> Port X and Port Y --> Choose this option to monitor all traffic received by port X (destined to port Y) and then transmitted by port Y (one way conversation steering).

Port X and Port Y Choose this option to monitor all traffic received by port X and then transmitted by port Y or transmitted by port X and received by port Y (two way conversation steering).

Selecting any one of the address-based monitoring modes activates the Address A and Address B screen fields, where you can specify MAC addresses to monitor.

Item Description

Page 71 of the Panasonic 470 user manual — Viewing port statistics
Page 71 · click to enlarge
Page 71

Viewing system statistics 71

Table 26 "Address-based monitoring modes" (page 71) describes the address-based monitoring modes.

Table 26 Address-based monitoring modes

Disabled Choose this option to disable port-based monitoring.

The default setting is Disabled.

Address A --> any Address Choose this option to monitor all traffic transmitted from Address A to any address.

any Address --> Address A Choose this option to monitor all traffic received by Address A from any address.

Address A Choose this option to monitor all traffic received by or transmitted by Address A.

Address A --> Address B Choose this option to monitor all traffic transmitted by Address A that goes to Address (one way conversation steering).

Address A Address B Choose this option to monitor all traffic received by Address A and then transmitted by Address B or transmitted by Address A and received by Address B (two way conversation steering).

—End—

Viewing system statistics

The options available to monitor system statistical data are:

  • "Viewing port statistics" (page 71)
  • "Viewing all port errors" (page 74)
  • "Viewing interface statistics" (page 76)
  • "Viewing Ethernet error statistics" (page 77)
  • "Viewing transparent bridging statistics" (page 79)

Viewing port statistics

You can view detailed statistics about a selected switch port in a stacked or stand-alone configuration. Both received and transmitted statistics are displayed so that you can compare throughput or other port parameters.

To view statistical data about a selected switch port:

Item Description

Page 72 of the Panasonic 470 user manual — Step Action
Page 72 · click to enlarge
Page 72

72 Chapter 4 Configuring network monitoring using Web-based management

Step Action

1 From the main menu, choose Statistics > Port.

The Port page opens (Figure 23 "Port page" (page 72)).

Figure 23 Port page

Panasonic 470 — Step Action diagram (page 72)
Fig. 25 · Step Action

Table 27 "Port page items" (page 72) describes the items on the Port page.

Table 27 Port page items

Unit The number of the switch to monitor. Port Statistics (View By) Port The switch port number to monitor.

Packets The number of packets received/transmitted on this port, including bad packets, broadcast packets, and multicast packets.

Multicast The number of good multicast packets received/transmitted on this port, excluding broadcast packets.

Broadcasts The number of good broadcast packets received/transmitted on this port.

Total Octets The number of octets of data received/transmitted on this port, including data in bad packets and Frame Check Sequence (FCS) octets, and framing bits.

Section Item Description · Port Statistics Table

Page 73 of the Panasonic 470 user manual — Figure 23 Port page
Page 73 · click to enlarge
Page 73

Viewing system statistics 73

Lost Packets The number of packets discarded on this port when the capacity of the port transmit buffer was exceeded.

Packets = 64 bytes The number of packets this size received/transmitted successfully on this port.

Packets 65-127 bytes The number of packets this size received/transmitted successfully on this port.

The number of packets this size received/transmitted successfully on this port.

The number of packets this size received/transmitted successfully on this port.

The number of packets this size received/transmitted successfully on this port.

The number of packets this size received/transmitted successfully on this port.

FCS Errors The number of valid-size packets received on this port with proper framing but discarded because of cyclic redundancy check (CRC) errors.

Undersized Packets The number of packets received on this port with fewer than 64 bytes and with proper CRC and framing (also known as short frames or runts).

Oversized Packets The number of packets received on this port with proper CRC and framing that meet the following requirements:

  • 1518 bytes if no VLAN tag exists
  • 1522 bytes if a VLAN tag exists

Filtered Packets The number of packets filtered, but not forwarded on this port.

Flooded Packets The number of packets flooded (forwarded) through this port because the destination address was not recognized in the address database.

Frame Errors The number of valid-size packets received on this port but discarded because of CRC errors and improper framing.

Collisions The number of collisions detected on this port.

Single Collisions The number of packets transmitted successfully on this port after a single collision.

Show 5 more labels / short text on this page
Section Item Description · Packets 128-255 bytes · Packets 256-511 bytes · Packets 512-1023 bytes · Packets 1024-1518 bytes
Page 74 of the Panasonic 470 user manual — Step Action
Page 74 · click to enlarge
Page 74

74 Chapter 4 Configuring network monitoring using Web-based management

Multiple Collisions The number of packets transmitted successfully on this port after more than one collision.

Excessive Collisions The number of packets lost on this port due to excessive collisions.

Deferred Packets The number of frames delayed on the first transmission attempt, but that never incurred a collision.

Late Collisions The number of packet collisions that occurred after a total length of time exceeding 512 bit-times of packet transmission.

2 In the Port Statistics section, choose the unit number and its port number.

3 Click Submit.

The Port Statistics Table is updated with information about the selected device and port (Figure 23 "Port page" (page 72)).

4 To update the statistical information, click Update.

—End—

Zeroing ports To clear the statistical information for the currently displayed port:

è Click Zero Port.

To clear the statistical information for all ports in a switch or stack configuration:

è Click Zero All Ports.

Viewing all port errors

You can view all ports in the entire stack that have an error. If a particular port has no errors, it is not displayed.

To view a summary of the port errors for the Ethernet Switch:

Step Action

1 From the main menu, choose Statistics > Port Error Summary.

The Port Error Summary page opens (Figure 24 "Port Error Summary page" (page 75)).

Section Item Description

Page 75 of the Panasonic 470 user manual — —End—
Page 75 · click to enlarge
Page 75

Viewing system statistics 75

Figure 24 Port Error Summary page

Panasonic 470 — Figure 24 Port Error Summary page diagram (page 75)
Fig. 26 · Figure 24 Port Error Summary page

Table 28 "Port Error Summary Table fields" (page 75) describes the read-only information displayed in the Port Error Summary Table.

Table 28 Port Error Summary Table fields

Unit Displays the unit number in the stack.

Port Displays the port number of the unit.

Status Displays the status of the port (Enabled/Disabled).

Link Displays the link status of the port (Up/Down).

Speed/Duplex Displays the speed at which the port is operating, as well as whether it is in half- or full-duplex mode.

Frame Errors Displays the number of frame errors received on this port.

FCS Errors Displays the number of frame check sequence (FCS) errors received on this port.

Late Collisions Displays the number of late collisions errors received on this port.

Multiple Collisions Displays the number of multiple collisions errors received on this port.

Excessive Collisions Displays the number of excessive collisions errors received on this port.

2 To view the latest port statistics, click the Update button at the bottom of the page.

—End—

Item Description

Page 76 of the Panasonic 470 user manual — Step Action
Page 76 · click to enlarge
Page 76

76 Chapter 4 Configuring network monitoring using Web-based management

Viewing interface statistics

You can view selected switch interface statistics.

To view statistical information for an interface:

Step Action

1 From the main menu, choose Statistics > Interface.

The Interface page opens (Figure 25 "Interface page" (page 76)).

Figure 25 Interface page

Panasonic 470 — Step Action diagram (page 76)
Fig. 27 · Step Action

Table 29 "Interface page items" (page 76) describes the items on the Interface page.

Table 29 Interface page items

Port The port number corresponding to the selected switch.

In Octets The number of octets received on the interface, including framing characters.

Out Octets The number of octets transmitted out of the interface, including framing characters.

In Unicast The number of subnetwork-unicast packets delivered to a higher-layer protocol.

Out Unicast The number of packets that higher-layer protocols requested be transmitted to a subnetwork-unicast address, including those discarded or not sent.

In Non-Unicast The number of non-unicast packets, for example, subnetwork-broadcast or subnetwork-multicast packets, delivered to a higher protocol.

Item Description

Page 77 of the Panasonic 470 user manual — Step Action
Page 77 · click to enlarge
Page 77

Viewing system statistics 77

Out Non-Unicast The number of packets that higher-level protocols requested be transmitted to a non-unicast address. For example, a subnetwork-broadcast or a subnetwork multicast address, including those discarded or not sent.

In Discards The number of inbound packets selected to be discarded even though no errors were detected to prevent their delivery to a higher-layer protocol. Packet discarding is not arbitrary. One reason for discarding packets is to free buffer space.

Out Discards The number of outbound packets selected to be discarded even though no errors were detected to prevent their being transmitted. Packet discarding is not arbitrary. One reason for discarding packets is to free buffer space.

In Errors The number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol.

Out Errors The number of outbound packets not transmitted because of errors.

In Unknown Protos The number of packets received through the interface that were discarded because of an unknown or unsupported protocol.

2 In the upper-left hand corner, click on the unit number of the device to monitor.

The page is updated with the information for the selected device (Figure 25 "Interface page" (page 76)).

3 To update the statistical information, click Update.

4 To update the statistical information, click Update, or click Back to return to the Interface page.

—End—

Viewing Ethernet error statistics

You can view Ethernet error statistics for each monitored interface linked to the Ethernet Switches 460 and 470.

To view Ethernet error statistics:

Step Action

1 From the main menu, choose Statistics > Ethernet Errors.

The Ethernet Errors page opens (Figure 26 "Ethernet Errors page" (page 78)).

Item Description

Page 78 of the Panasonic 470 user manual — Figure 26 Ethernet Errors page
Page 78 · click to enlarge
Page 78

78 Chapter 4 Configuring network monitoring using Web-based management

Figure 26 Ethernet Errors page

Panasonic 470 — Figure 26 Ethernet Errors page diagram (page 78)
Fig. 28 · Figure 26 Ethernet Errors page

Table 30 "Ethernet Errors page items" (page 78) describes the items on the Ethernet Errors page.

Table 30 Ethernet Errors page items

Port The port number corresponding to the selected switch.

Alignment Errors The number of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check.

FCS Errors The number of frames received on a particular interface that are an integral number of octets in length, but do not pass the FCS check.

Internal MAC Transmit Errors

The number of frames for which transmission on a particular interface fails due to an internal MAC sublayer transmit error. A frame is added to this counter only if it is not counted as a late collision error, excessive collisions error, or as a carrier sense error.

Internal MAC Receive Errors

The number of frames for which reception on a particular interface fails due to an internal MAC sublayer transmit error. A frame is added to this counter only if it is not counted as a late collision error, excessive collisions error, or as a carrier sense error.

Carrier Sense Errors The number of times that the carrier sense conditions were lost or never asserted when attempting to transmit a frame on a particular interface.

Frame Too Long The number of frames received on a particular interface that exceed the maximum permitted frame size.

Item Description

Page 79 of the Panasonic 470 user manual — Step Action
Page 79 · click to enlarge
Page 79

Viewing system statistics 79

SQE Test Errors The number of times that the SQE TEST ERROR message is generated by the PLS sublayer for a particular interface. The SQE TEST ERROR is defined in section 7.2.2.2.4 of ANSI/IEEE 802.3-1985, and its generation is described in section 7.2.4.6 of the same document.

The number of frames for which the first transmission attempt on a particular interface is delayed because the medium is busy.

The number of successfully transmitted frames on a particular interface for which transmission is inhibited by more than one collision.

The number of successfully transmitted frames on a particular interface for which transmission is inhibited by a single collision.

Late Collisions The number of times a collision is detected on a particular interface later than 512 bit-times into the transmission of a packet.

Excessive Collisions The number of frames for which transmission on a particular interface fails due to excessive collisions.

2 In the upper-left hand corner, click on the unit number of the device to monitor.

The table is updated with the information for the selected device.

3 To refresh the statistical information, click Update.

4 To update the statistical information, click Update, or click Back to return to the Ethernet Errors page

—End—

Viewing transparent bridging statistics

You can view the transparent bridging statistics measured for each monitored interface on the device.

To view transparent bridging statistics:

Step Action

1 From the main menu, choose Statistics > Transparent Bridging.

The Transparent Bridging page opens (Figure 27 "Transparent Bridging page" (page 80)).

Show 4 more labels / short text on this page
Item Description · Deferred Transmissio ns · Single Collision Frames · Multiple Collision Frames
Page 80 of the Panasonic 470 user manual — Figure 27 Transparent Bridging page
Page 80 · click to enlarge
Page 80

80 Chapter 4 Configuring network monitoring using Web-based management

Figure 27 Transparent Bridging page

Panasonic 470 — Figure 27 Transparent Bridging page diagram (page 80)
Fig. 29 · Figure 27 Transparent Bridging page

Table 31 "Transparent Bridging page items" (page 80) describes the items on the Transparent Bridging page.

Table 31 Transparent Bridging page items

Port The port number that corresponds to the selected switch.

In Frames The number of frames that have been received by this port from its segment. A frame received on the interface corresponding to this port is counted only if it is for a protocol being processed by the local bridging function, including bridge management errors.

Out Frames The number of frames that have been transmitted by this port from its segment. A frame received on the interface corresponding to this port is counted only if it is for a protocol being processed by the local bridging function, including bridge management errors.

In Discards The number of valid frames received which were discarded by the forwarding process.

2 In the upper-left hand corner, click the unit number of the device to monitor.

The page is updated with statistics about the selected device and its corresponding port number.

3 To refresh the statistical information, click Update.

Item Description

Page 81 of the Panasonic 470 user manual — Step Action
Page 81 · click to enlarge
Page 81

Monitoring MLT traffic 81

—End—

Monitoring MLT traffic

You can monitor the bandwidth usage for the MultiLink Trunk member ports within each trunk in your configuration by selecting the traffic type to monitor.

To monitor MultiLink Trunk traffic:

Step Action

1 From the main menu, choose Application > MultiLink Trunk > Utilization.

The Utilization page opens (Figure 28 "Utilization page" (page 81)).

Figure 28 Utilization page

Panasonic 470 — Step Action diagram (page 81)
Fig. 30 · Step Action

Table 32 "Utilization page items" (page 81) describes the items on the Utilization page.

Table 32 Utilization page items

Section Item Range Description

Trunk 1..6 Choose the trunk to be monitored. MultiLink Trunk Utilization Selection (View By)

Traffic Type (1) RX and TX (2) RX (3) TX

Choose the traffic type to be monitored for percentage of bandwidth utilization.

Page 82 of the Panasonic 470 user manual — —End—
Page 82 · click to enlarge
Page 82

82 Chapter 4 Configuring network monitoring using Web-based management

Section Item Range Description

MultiLink Trunk Utilization Table

Unit/Port A list of the trunk member switch ports that correspond to the trunk specified in the Trunk column.

Last 5 Minutes% The percentage of packets (of the type specified in the Traffic Type field) used by the port in the last five minutes. This field provides a running average of network activity, and is updated every 15 seconds.

The percentage of packets (of the type specified in the Traffic Type field) used by the port in the last 30 minutes. This field provides a running average of network activity, and is updated every 15 seconds.

Last Hour% The percentage of packets (of the type specified in the Traffic Type field) used by the port in the last 60 minutes. This field provides a running average of network activity, and is updated every 15 seconds.

2 In the MultiLink Trunk Utilization Selection section, type the Trunk number and traffic type to be monitored.

3 Click Submit.

The results of your request are displayed in the MultiLink Trunk Utilization Table ( Figure 28 "Utilization page" (page 81)).

—End—

Last 30 Minutes%

Page 83 of the Panasonic 470 user manual — show rmon alarm
Page 83 · click to enlarge
Page 83

Chapter 5 Configuring RMON using the CLI

The remote network monitoring (RMON) management information base (MIB) is an interface between the RMON agent on an Ethernet Switch and the RMON management applications. It defines objects that are suitable for the management of any type of network. Some groups are specifically targeted for Ethernet networks.

The RMON agent continuously collects statistics and proactively monitors the switch.

This chapter covers the RMON commands available in the CLI and includes the following topics:

  • "show rmon alarm" (page 83)
  • "show rmon event" (page 84)
  • "show rmon history" (page 84)
  • "show rmon stats" (page 85)
  • "rmon alarm" (page 86)
  • "no rmon alarm" (page 87)
  • "rmon event" (page 88)
  • "no rmon event" (page 88)
  • "rmon history" (page 88)
  • "no rmon history" (page 89)
  • "rmon stats" (page 89)
  • "no rmon stats" (page 90)

show rmon alarm

The show rmon alarm command displays information for RMON alarms. The syntax for the show rmon alarm command is:

show rmon alarm

Page 84 of the Panasonic 470 user manual — show rmon history
Page 84 · click to enlarge
Page 84

84 Chapter 5 Configuring RMON using the CLI

The show rmon alarm command is in the privExec mode.

The show rmon alarm command has no parameters or variables.

Figure 29 "show rmon alarm command output" (page 84) displays a sample output of the show rmon alarm command.

Figure 29 show rmon alarm command output

Panasonic 470 — show rmon event diagram (page 84)
Fig. 31 · show rmon event

show rmon event

The show rmon event command displays information regarding RMON events. The syntax for the show rmon event command is:

The show rmon event command is in the privExec mode.

The show rmon event command has no parameters or variables.

Figure 30 "show rmon event command output" (page 84) displays a sample output of the show rmon event command.

Figure 30 show rmon event command output

Panasonic 470 — show rmon event diagram (page 84)
Fig. 32 · show rmon event

show rmon history

The show rmon history command displays information regarding RMON history. The syntax for the show rmon history command is:

The show rmon history command is in the privExec mode.

The show rmon history command has no parameters or variables.

show rmon event · show rmon history

Page 85 of the Panasonic 470 user manual — show rmon stats
Page 85 · click to enlarge
Page 85

show rmon stats 85

Figure 31 "show rmon history command output" (page 85) displays a sample output of the show rmon history command.

Figure 31 show rmon history command output

Panasonic 470 — show rmon stats diagram (page 85)
Fig. 33 · show rmon stats

show rmon stats

The show rmon stats command displays information regarding RMON statistics. The syntax for the show rmon stats command is:

The show rmon stats command is in the privExec mode.

The show rmon stats command has no parameters or variables.

Figure 32 "show rmon stats command output" (page 86) displays a sample output of the show rmon stats command.

show rmon stats

Page 86 of the Panasonic 470 user manual — rmon alarm
Page 86 · click to enlarge
Page 86

86 Chapter 5 Configuring RMON using the CLI

Figure 32 show rmon stats command output

Panasonic 470 — rmon alarm diagram (page 86)
Fig. 34 · rmon alarm

rmon alarm

The rmon alarm command allows you to set RMON alarms and thresholds. The syntax for the rmon alarm command is:

rmon alarm <1-65535> <WORD> <1-2147483647> {absolute | delta} rising threshold <-2147483648-2147483647> [<1-65535>] falling-threshold <-2147483648-2147483647> [<1-65535>] [owner <LINE>]

The rmon alarm command is in the config command mode.

Table 33 "rmon alarm command parameters and variables" (page 86) describes the parameters and variables for the rmon alarm command.

Table 33 rmon alarm command parameters and variables

Parameters and variables Description

<1-65535> Unique index for the alarm entry.

<WORD> The MIB object to be monitored. This is an object identifier (OID) and, for most available objects, an English name can be used.

Page 87 of the Panasonic 470 user manual — no rmon alarm
Page 87 · click to enlarge
Page 87

no rmon alarm 87

Parameters and variables Description

<1-2147483647> The sampling interval in seconds.

absolute Use absolute values (value of the MIB object is compared directly with thresholds).

delta Use delta values (change in value of the MIB object between samples is compared with thresholds).

The first integer value is the rising threshold value. The optional second integer specifies the event entry triggered when the rising threshold is crossed. If omitted, or if an invalid event entry is referenced, no event is triggered.

The first integer value is the falling threshold value. The optional second integer specifies the event entry triggered when the falling threshold is crossed. If omitted, or if an invalid event entry is referenced, no event is triggered.

[owner <LINE>] Specifies an owner string to identify alarm entry.

no rmon alarm

The no rmon alarm command deletes RMON alarm table entries. When the variable is omitted, all entries in the table are cleared. The syntax for the no rmon alarm command is:

no rmon alarm [<1-65535>]

The no rmon alarm command is in the config command mode.

Table 34 "no rmon alarm command parameters and variables" (page 87) describes the parameters and variables for the no rmon alarm command.

Table 34 no rmon alarm command parameters and variables

Parameters and variables Description

<1-65535> Unique index for the alarm entry.

rising-threshold <-2147483648-2147483647> [<1-65535>] · falling-threshold <-2147483648-2147483647> [<1-65535>]

Page 88 of the Panasonic 470 user manual — rmon history
Page 88 · click to enlarge
Page 88

88 Chapter 5 Configuring RMON using the CLI

rmon event

The rmon event command allows you to configure RMON event log and trap settings. The syntax for the rmon event command is:

rmon event <1-65535> [log] [trap] [description <LINE>] [owner <LINE>]

The rmon event command is in the config command mode.

Table 35 "rmon event command parameters and variables" (page 88) describes the parameters and variables for the rmon event command.

Table 35 rmon event command parameters and variables

Parameters and variables Description

<1-65535> Unique index for the event entry.

[log] Record events in the log table.

[trap] Generate SNMP trap messages for events.

[description <LINE>] Specify a textual description for the event.

[owner <LINE>] Specify an owner string to identify the event entry

no rmon event

The no rmon event command deletes RMON event table entries. When the variable is omitted, all entries in the table are cleared. The syntax for the no rmon event command is:

no rmon event [<1-65535>]

The no rmon event command is in the config command mode.

Table 36 "no rmon event command parameters and variables" (page 88) describes the parameters and variables for the no rmon event command.

Table 36 no rmon event command parameters and variables

Parameters and variables Description

<1-65535> Unique index for the event entry.

rmon history

The rmon history command allows you to configure RMON history settings. The syntax for the rmon history command is:

Page 89 of the Panasonic 470 user manual — rmon stats
Page 89 · click to enlarge
Page 89

rmon history <1-65535> <LINE> <1-65535> <1-3600> [owner <LINE>]

The rmon history command is in the config command mode.

Table 37 "rmon history command parameters and variables" (page 89) describes the parameters and variables for the rmon history command.

Table 37 rmon history command parameters and variables

Parameters and variables Description

<1-65535> Unique index for the history entry.

<LINE> Specify the port number to be monitored.

<1-65535> Number of history buckets (records) to keep.

<1-3600> Sampling rate (how often a history sample is collected).

[owner <LINE>] Specify an owner string to identify the history entry.

no rmon history

The no rmon history command deletes RMON history table entries. When the variable is omitted, all entries in the table are cleared. The syntax for the no rmon history command is:

no rmon history [<1-65535>]

The no rmon history command is in the config command mode.

Table 38 "no rmon history command parameters and variables" (page 89) describes the parameters and variables for the no rmon history command.

Table 38 no rmon history command parameters and variables

Parameters and variables Description

<1-65535> Unique index for the history entry.

rmon stats

The rmon stats command allows you to configure RMON statistic settings. The syntax for the rmon stats command is:

rmon stats <1-65535> <port> [owner <LINE>]

The rmon stats command is in the config command mode.

rmon stats 89

Page 90 of the Panasonic 470 user manual — no rmon stats
Page 90 · click to enlarge
Page 90

90 Chapter 5 Configuring RMON using the CLI

Table 39 "rmon stats command parameters and variables" (page 90) describes the parameters and variables for the rmon stats command.

Table 39 rmon stats command parameters and variables

Parameters and variables Description

<1-65535> Unique index for the stats entry.

<port> Specifies a port for the stats.

[owner <LINE>] Specifies an owner string to identify the stats entry.

no rmon stats

The no rmon stats turns off RMON statistics. When the variable is omitted, all table entries are cleared. The syntax for the no rmon stats command is:

no rmon stats [<1-65535>]

The no rmon stats command is in the config command mode.

Table 40 "no rmon stats command parameters and variables" (page 90) describes the parameters and variables for the no rmon stats command.

Table 40 no rmon stats command parameters and variables

Parameters and variables Description

<1-65535> Unique index for the stats entry.

Page 91 of the Panasonic 470 user manual — Working with RMON information
Page 91 · click to enlarge
Page 91

Chapter 6 Configuring RMON using Device Manager

The Remote Network Monitoring (RMON) MIB is an interface between the RMON agent on an Ethernet Switch and an RMON management application, such as the Device Manager.

The RMON MIB defines objects that are suitable for the management of any type of network, but some groups are targeted for Ethernet networks in particular.

The RMON agent continuously collects statistics and proactively monitors switch performance. You can view this data through the Device Manager.

RMON has three major functions:

  • Creating and displaying alarms for user-defined events
  • Gathering cumulative statistics for Ethernet interfaces
  • Tracking a history of statistics for Ethernet interfaces

This chapter contains the following topics:

  • "Working with RMON information" (page 91)
  • "RMON Alarms" (page 98)
  • "RMON events" (page 106)
  • "RMON Log information" (page 109)

Working with RMON information

You can view RMON information by looking at the Graph information associated with the port or chassis.

Page 92 of the Panasonic 470 user manual — Step Action
Page 92 · click to enlarge
Page 92

92 Chapter 6 Configuring RMON using Device Manager

RMON history

Ethernet history records periodic statistical samples from a network. A sample is called a history and is gathered in time intervals referred to as buckets. Histories establish a time-dependent method for gathering RMON statistics on a port. The default values for history are:

  • Buckets are gathered at 30-minute intervals.
  • Number of buckets gathered is 50.

Both the time interval and the number of buckets is configurable. However, when the last bucket is reached, bucket 1 is dumped and "recycled" to hold a new bucket of statistics. Then bucket 2 is dumped, and so forth.

Creating a history

You can use RMON to collect statistics at intervals. For example, if you want RMON statistics to be gathered over the weekend, you require enough buckets to cover two days. To do this, set the history to gather one bucket each hour, thus covering a 48-hour period. After you set history characteristics, you cannot modify them; you must delete the history and create another one.

To establish a history for a port and set the bucket interval:

Step Action

1 From the Device Manager main menu, choose Rmon > Control.

The RmonControl dialog box opens with the History tab displayed Figure 33 "History tab" (page 92).

Figure 33 History tab

Panasonic 470 — Step Action diagram (page 92)
Fig. 35 · Step Action

2 Click Insert.

The RmonControl, Insert History dialog box opens (Figure 34 "RmonControl, Insert History dialog box" (page 93)).

Page 93 of the Panasonic 470 user manual — —End—
Page 93 · click to enlarge
Page 93

Working with RMON information 93

Figure 34 RmonControl, Insert History dialog box

Panasonic 470 — Figure 34 RmonControl, Insert History dialog box diagram (page 93)
Fig. 36 · Figure 34 RmonControl, Insert History dialog box

3 Select the port from the port list or type the port number.

4 Set the number of buckets.

The default is 50.

5 Set the interval.

The default is 1800 seconds.

6 Type the owner (the network management system that created this entry).

Click Insert.

—End—

Table 41 "History tab fields" (page 93) describes the History tab of the RmonControl dialog box.

Table 41 History tab fields

Index A unique value assigned to each interface. An index identifies an entry in a table.

Port Any Ethernet interface on the device.

BucketsRequested The requested number of discrete time intervals over which data is to be saved in the part of the media-specific table associated with this entry.

BucketsGranted The number of discrete sampling intervals over which data is saved in the part of the media-specific table associated with this entry. There are instances when the actual number of buckets associated with this entry is less than the value of this object. In this case, at the end of each sampling interval, a new bucket is added to the media-specific table.

Field Description

Page 94 of the Panasonic 470 user manual — —End—
Page 94 · click to enlarge
Page 94

94 Chapter 6 Configuring RMON using Device Manager

Interval The interval in seconds over which the data is sampled for each bucket in the part of the media-specific table associated with this entry. You can set this interval to any number of seconds between 1 and 3600 (1 hour). Because the counters in a bucket can overflow at their maximum value with no indication, note the possibility of overflow in any of the associated counters. It is important to consider the minimum time in which any counter can overflow on a particular media type; set the historyControlInterval object to a value less than this interval. This is typically most important for the octets counter in any media-specific table. For example, on an Ethernet network, the etherHistoryOctets counter can overflow in about one hour at the Ethernet maximum utilization.

Owner The network management system that created this entry.

Disabling history

To disable RMON history on a port:

Step Action

1 From the Device Manager main menu, choose Rmon > Control.

The RmonControl dialog box opens with the History tab displayed (Figure 33 "History tab" (page 92)).

2 Highlight the row that contains the port ID you want to delete.

3 Click Delete.

The entry is removed from the table.

—End—

Viewing RMON history statistics

To display RMON history statistics:

è In the Rmon History tab, highlight an entry and click on the Graph button.

The Rmon History statistics dialog box opens (Figure 35 "Rmon History statistics" (page 95)).

Field Description

Page 95 of the Panasonic 470 user manual — Figure 35 Rmon History statistics
Page 95 · click to enlarge
Page 95

Working with RMON information 95

Figure 35 Rmon History statistics

Panasonic 470 — Figure 35 Rmon History statistics diagram (page 95)
Fig. 37 · Figure 35 Rmon History statistics

Table 42 "Rmon History statistics tab fields" (page 95) describes the Rmon History statistics tab fields.

Table 42 Rmon History statistics tab fields

SampleIndex Indicates the sample number. As history samples are taken, they are assigned greater sample numbers.

Utilization Estimates the percentage of link capacity used during the sampling interval.

Octets The number of octets received on the link during the sampling period.

Pkts The number of packets received on the link during the sampling period.

The number of packets received on the link during the sampling interval that are destined for the packet address.

The number of packets received on the link during the sampling interval that are destined for the multicast address. This doe not include the broadcast packets.

DropEvents The number of received packets dropped due to system resource constraints.

The number of packets received during a sampling interval that were between 64 and 1518 octets long that had a bad FCS with either an integral number of octets (FCS Error) or a non-integral number of octets (Alignment Error). The packet length includes Frame Check Sequence (FCS) octets but not framing bits.

Show 4 more labels / short text on this page
Field Description · BroadcastPk ts · MulticastPkt s · CRCAlignErr ors
Page 96 of the Panasonic 470 user manual — Step Action
Page 96 · click to enlarge
Page 96

96 Chapter 6 Configuring RMON using Device Manager

The number of packets received during the sampling interval that were less than 64 octets long (including FCS octets, but not framing bits).

The number of packets received during the sampling interval that were longer than 1518 octets (including FCS octets, but not framing bits) and were otherwise well-formed.

Fragments The number of packets received during the sampling interval that were less than 64 octets long (including FCS octets, but not framing bits) that had a bad FCS with either an integral number of octets (FCS Error) or a non-integral number of octets (Alignment Error).

Collisions The best estimate of the number of collisions on an Ethernet segment during a sampling interval.

Enabling Ethernet statistics gathering

You can use RMON to gather Ethernet statistics.

To gather Ethernet statistics:

Step Action

1 From the Device Manager main menu, choose RMon > Control.

The RmonControl dialog box opens with the History tab displayed.

2 Click the Ether Stats tab.

The Ether Stats tab opens (Figure 36 "RmonControl dialog box -- Ether Stats tab" (page 96)).

Figure 36 RmonControl dialog box -- Ether Stats tab

Panasonic 470 — Step Action diagram (page 96)
Fig. 38 · Step Action

3 Click Insert.

Field Description · UndersizePk ts · OversizePkt s

Page 97 of the Panasonic 470 user manual — —End—
Page 97 · click to enlarge
Page 97

Working with RMON information 97

The RmonControl, Insert Ether Stats dialog box opens (Figure 37 "RmonControl, Insert Ether Stats dialog box" (page 97)).

Figure 37 RmonControl, Insert Ether Stats dialog box

Panasonic 470 — Figure 37 RmonControl, Insert Ether Stats dialog box diagram (page 97)
Fig. 39 · Figure 37 RmonControl, Insert Ether Stats dialog box

4 Select the ports.

Enter the port number you want or select the port from the list menu (Figure 38 "RmonControl, Insert Ether Stats dialog box port list" (page 97)).

Figure 38 RmonControl, Insert Ether Stats dialog box port list

Panasonic 470 — Figure 37 RmonControl, Insert Ether Stats dialog box diagram (page 97)
Fig. 40 · Figure 37 RmonControl, Insert Ether Stats dialog box

Device Manager assigns the index.

5 Click Insert.

The new Ethernet Statistics entry is shown in the Ether Stats tab.

—End—

Table 43 "Ether Stats tab fields" (page 97) describes the Ether Stats tab fields.

Table 43 Ether Stats tab fields

Index A unique value assigned to each interface. An index identifies an entry in a table.

Port Any Ethernet interface on the device.

Owner The network management system that created this entry.

Field Description

Page 98 of the Panasonic 470 user manual — How RMON alarms work
Page 98 · click to enlarge
Page 98

98 Chapter 6 Configuring RMON using Device Manager

Disabling Ethernet statistics gathering

To disable Ethernet statistics that you have set:

Step Action

1 From the Device Manager main menu, choose Rmon > Control.

The RmonControl dialog box opens with the History tab displayed.

2 Click the Ether Stats tab.

The Ether Stats tab opens (Figure 36 "RmonControl dialog box -- Ether Stats tab" (page 96)).

3 Highlight the row that contains the port ID you want to delete.

4 Click Delete.

The Ether Stats entry is removed from the table.

—End—

RMON Alarms

Alarms are useful when you need to know when the values of a variable go outside a specified range. You can define an RMON alarm for any MIB variable that resolves to an integer value. You cannot use string variables (such as system description) as alarm variables.

All alarms share the following characteristics:

  • An upper and lower threshold value is defined.
  • A corresponding rising and falling event occurs.
  • An alarm interval or polling period is reached.

When alarms are activated, you can view the activity in a log or a trap log, or you can create a script to notify you by beeping a console, sending e-mail, or calling a pager.

How RMON alarms work

The alarm variable is polled and the result is compared against upper and lower limit values you select when you create the alarm. If either limit is reached or crossed during the polling period, then the alarm fires and generates an event that you can view in the event log or the trap log.

The upper limit of the alarm is called the rising value, and its lower limit is called the falling value. RMON periodically samples the data based upon the alarm interval. During the first interval that the data passes above the

Page 99 of the Panasonic 470 user manual — Figure 39 How alarms fire
Page 99 · click to enlarge
Page 99

rising value, the alarm fires as a rising event. During the first interval that the data drops below the falling value, the alarm fires as a falling event (Figure 39 "How alarms fire" (page 99)).

Figure 39 How alarms fire

Panasonic 470 — Figure 39 How alarms fire diagram (page 99)
Fig. 41 · Figure 39 How alarms fire

It is important to note that the alarm fires during the first interval in which the sample goes out of range. No additional events are generated for that threshold until the opposite threshold is crossed. Therefore, you must carefully define the rising and falling threshold values for alarms to work as expected. Otherwise, incorrect thresholds cause an alarm to fire at every alarm interval.

A general guideline is to define one of the threshold values to an expected, baseline value, and then define the opposite threshold as the out-of-bounds limit. Because of sample averaging, the value can be equal to ±1 of the baseline units. For example, assume an alarm is defined on octets going out of a port as the variable. The intent of the alarm is to provide notification to the system administrator when excessive traffic occurs on that port. If spanning tree is enabled, then 52 octets are transmitted out of the port every 2 seconds, which is equivalent to baseline traffic of 260 octets every 10 seconds. This alarm provides the notification the system administrator needs if the lower limit of octets going out is defined at 260 and the upper limit is defined at 320 (or at any value greater than 260 + 52 = 312).

The first time outbound traffic other than spanning tree Bridge Protocol Data Units (BPDUs) occurs, the rising alarm fires. When outbound traffic other than spanning tree ceases, the falling alarm fires. This process provides the system administrator with time intervals of any non-baseline outbound traffic.

If the alarm is defined with a falling threshold less than 260 (assuming the alarm polling interval is 10 seconds), say 250, then the rising alarm can fire only once (Figure 40 "Alarm example -- threshold less than 260" (page 100)). The reason is that for the rising alarm to fire a second time, the falling alarm (the opposite threshold) must fire. Unless the port becomes inactive or spanning tree is disabled (which causes the value for outbound octets

RMON Alarms 99

Page 100 of the Panasonic 470 user manual — Alarm Manager example
Page 100 · click to enlarge
Page 100

100 Chapter 6 Configuring RMON using Device Manager

to drop to zero), the falling alarm cannot fire, because the baseline traffic is always greater than the value of the falling threshold. By definition, the failure of the falling alarm to fire prevents the rising alarm from firing a second time.

Figure 40 Alarm example -- threshold less than 260

Panasonic 470 — Creating alarms diagram (page 100)
Fig. 42 · Creating alarms

Creating alarms

When you create an alarm, you select a variable from the variable list and a port, or other switch component, to which it is connected. Some variables require port IDs, card IDs, or other indices (for example, spanning tree group IDs). You then select a rising and a falling threshold value. The rising and falling values are compared against the actual value of the variable that you choose. If the variable falls outside of the rising or falling value range, an alarm is triggered, and an event is logged or trapped.

When you create an alarm, you also select a sample type, which can be either absolute or delta. Absolute alarms are defined on the cumulative value of the alarm variable. An example of an alarm defined with absolute value is card operating status. Because this value is not cumulative, but instead represents states, such as card up (value 1) and card down (value 2), you set it for absolute value. Therefore, you can create an alarm with a rising value of 2 and a falling value of 1 to alert a user to whether the card is up or down.

Most alarm variables related to Ethernet traffic are set to delta value. Delta alarms are defined based on the difference in the value of the alarm variable between the start of the polling period and the end of the polling period. Delta alarms are sampled twice per polling period. For each sample, the last two values are added together and compared to the threshold values. This process increases precision and allows for the detection of threshold crossings that span the sampling boundary. Therefore, if you track the current values of a given delta-valued alarm and add them together, the result is twice the actual value. (This result is not an error in the software.)

Alarm Manager example

Page 101 of the Panasonic 470 user manual — Step Action
Page 101 · click to enlarge
Page 101

intended only to demonstrate how alarms fire; it is not a useful alarm. Because of the high frequency, delete this alarm and replace it with a practical setting.

To create an alarm to receive statistics and history using default values:

Step Action

1 Do one of the following:

  • From the Device Manager main menu, choose Rmon >Alarm Manager.
  • On the toolbar, click the Alarm Manager button.

The Alarm Manager dialog box opens (Figure 41 "Alarm Manager dialog box" (page 101)).

Figure 41 Alarm Manager dialog box

Panasonic 470 — Step Action diagram (page 101)
Fig. 43 · Step Action

2 In the variable field, select a variable for the alarm from the list and a port (or other ID) on which you want to set an alarm (Figure 42 "Alarm variable list" (page 102)).

RMON Alarms 101

Page 102 of the Panasonic 470 user manual — —End—
Page 102 · click to enlarge
Page 102

102 Chapter 6 Configuring RMON using Device Manager

Figure 42 Alarm variable list

Panasonic 470 — Figure 42 Alarm variable list diagram (page 102)
Fig. 44 · Figure 42 Alarm variable list

Alarm variables are in three formats, depending on the type:

  • A chassis alarm ends in x where the x index is hard-coded. No further information is required.
  • A card, spanning tree group (STG) or EtherStat alarm ends with a dot (.). You must enter a card number, STG ID, IP address, or EtherStat information.
  • A port alarm ends with no dot or index and requires using the port shortcut menu. An example of a port alarm is ifInOctets (interface incoming octet count).
  • For this example, select Bridge > dot1dStpTopChanges.0 from the variable list. This example is a chassis alarm, indicated by the ".0" in the variable.

3 For this example, select a rising value of 4 and a falling value of 0.

4 Leave the remaining fields at their default values, including a sample type of Delta.

5 Click Insert.

If you want to make field changes, see the field descriptions shown in Table 44 "Rmon Insert Alarm dialog box fields" (page 103).

—End—

Page 103 of the Panasonic 470 user manual — Viewing RMON statistics
Page 103 · click to enlarge
Page 103

Alarm Manager dialog box fields

Table 44 Rmon Insert Alarm dialog box fields

Variable Name and type of alarm--indicated by the format:

alarmname.x where x=0 indicates a chassis alarm.

alarmname. where the user must specify the index. This is a card number for module-related alarms, an STG ID for spanning tree group alarms (the default STG is 1, other STG IDs are user-configured), or the Ether Statistics Control Index for RMON Stats alarms.

alarmname with no dot or index is a port-related alarm and results in display of the port selection tool.

Sample Type Can be either absolute or delta.

For more information about sample types, refer to "Creating alarms" (page 100).

Sample Interval Time period (in seconds) over which the data is sampled and compared with the rising and falling thresholds.

Index Uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device.

Threshold Type Rising Value Falling Value

Value When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval is less than this threshold, a single event is generated.

When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval is greater than this threshold, a single event is generated.

Event Index Index of the event entry used when a rising threshold is crossed. The event entry identified by a particular value of this index is the same as identified by the same value of the event index object. (Generally, accept the default that is already filled in.)

Index of the event entry used when a falling threshold is crossed. The event entry identified by a particular value of this index is the same as identified by the same value of the event index object. (Generally, accept the default that is already filled in.)

Viewing RMON statistics

To view the RMON statistics and history for the port for which you have created an alarm:

RMON Alarms 103 · Field Description

Page 104 of the Panasonic 470 user manual — —End—
Page 104 · click to enlarge
Page 104

104 Chapter 6 Configuring RMON using Device Manager

Step Action

1 Select the port on which you have created an alarm.

2 From the Device Manager main menu, choose Rmon > Control.

The RmonControl dialog box opens displaying the History tab (Figure 33 "History tab" (page 92)).

3 Click the Ether Stats tab to view statistics (Figure 36 "RmonControl dialog box -- Ether Stats tab" (page 96)).

—End—

To delete an alarm:

Step Action

1 From the Device Manager main menu, choose Rmon >Alarms.

The RmonAlarms dialog box opens with the Alarms tab (Figure 43 "RmonAlarms dialog box -- Alarms tab" (page 104)) displayed.

Figure 43 RmonAlarms dialog box -- Alarms tab

Panasonic 470 — Step Action diagram (page 104)
Fig. 45 · Step Action

2 Click any field for the alarm that you want to delete.

3 Click Delete.

—End—

Table 45 "Alarms tab fields" (page 104) describes the fields on the Alarms tab.

Table 45 Alarms tab fields

Index Uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device

Field Description

Page 105 of the Panasonic 470 user manual — Figure 43 RmonAlarms dialog box -- Alarms tab
Page 105 · click to enlarge
Page 105

Interval The interval in seconds over which data is sampled and compared with the rising and falling thresholds. When setting this variable, in the case of deltaValue sampling, set the interval short enough so that the sampled variable is unlikely to increase or decrease by more than 2^31 - 1 during a single sampling interval.

Variable The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Counter, Gauge, or TimeTicks) can be sampled.

Sample Type The method of sampling the selected variable and calculating the value to be compared against the thresholds. If the value of this object is absoluteValue(1), the value of the selected variable is compared directly with the thresholds at the end of the sampling interval. If the value of this object is deltaValue(2), the value of the selected variable at the last sample is subtracted from the current value, and the difference compared with the thresholds.

Value The value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value is the difference between the samples at the beginning and end of the period. If the sample type is absoluteValue, this value is the sampled value at the end of the period. This value is compared with the rising and falling thresholds. The value during the current sampling period is not made available until the period is completed and remains available until the next period completes.

StartupAlarm The alarm that can be sent when this entry is first set to valid. If the first sample after this entry becomes valid is greater than or equal to the risingThreshold and alarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3), then a single rising alarm is generated. If the first sample after this entry becomes valid is less than or equal to the fallingThreshold and alarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3), then a single falling alarm is generated.

RisingThreshold A threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event is generated. A single event is also generated after this entry becomes valid if the first sample is greater than or equal to this threshold and the associated alarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3). After a rising event is generated, another such event is not generated until the sampled value falls below this threshold and reaches the alarmFallingThreshold.

The index of the eventEntry that is used when a rising threshold is crossed. The eventEntry identified by a particular value of this index is the same as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In particular, if this value is zero, no associated event is generated, because zero is not a valid event index.

RMON Alarms 105 · Field Description · RisingEventInde x

Page 106 of the Panasonic 470 user manual — Step Action
Page 106 · click to enlarge
Page 106

106 Chapter 6 Configuring RMON using Device Manager

FallingThreshold A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event is generated. A single event is also generated after this entry becomes valid if the first sample is less than or equal to this threshold and the associated alarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3). After a falling event is generated, another such event is not generated until the sampled value rises above this threshold and reaches the alarmRisingThreshold.

The index of the eventEntry used when a falling threshold is crossed. The eventEntry identified by a particular value of this index is the same as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In particular, if this value is zero, no associated event is generated, because zero is not a valid event index.

Owner The network management system that created this entry.

Status The status of this alarm entry.

RMON events

RMON events and alarms work together to notify you when values in your network are outside of a specified range. When values pass the specified ranges, the alarm is triggered and fires. The event specifies how the activity is recorded.

How events work

An event specifies whether a trap, a log, or a trap and a log is generated to view alarm activity. When RMON is globally enabled, two default events are generated:

  • RisingEvent
  • FallingEvent

The default events specify that when an alarm goes out of range, the firing of the alarm is tracked in both a trap and a log. For example, when an alarm fires at the rising threshold, the rising event specifies that this information be sent to both a trap and a log. Likewise, when an alarm passes the falling threshold, the falling event specifies that this information be sent to a trap and a log.

Viewing an event

To view a table of events:

Step Action

1 From the Device Manager main menu, choose Rmon > Alarms.

Field Description · FallingEventInde x

Page 107 of the Panasonic 470 user manual — —End—
Page 107 · click to enlarge
Page 107

The RmonAlarms dialog box opens displaying the Alarms tab (Figure 43 "RmonAlarms dialog box -- Alarms tab" (page 104)).

2 Click the Events tab.

The Events tab opens (Figure 44 "RmonAlarms dialog box -- Events tab" (page 107)).

Figure 44 RmonAlarms dialog box -- Events tab

Panasonic 470 — Figure 44 RmonAlarms dialog box -- Events tab diagram (page 107)
Fig. 46 · Figure 44 RmonAlarms dialog box -- Events tab

—End—

Table 46 "Events tab fields" (page 107) describes the RmonAlarms Events tab fields.

Table 46 Events tab fields

Index This index uniquely identifies an entry in the event table. Each entry defines one event that is generated when the appropriate conditions occur.

Specifies whether the event is a rising or falling event.

Type The type of notification that the Device Manager provides about this event. In the case of log, an entry is made in the log table for each event. In the case of trap, an SNMP trap is sent to one or more management stations. Possible notifications follow:

  • none
  • log
  • trap
  • log-and-trap

The SNMP community string acts as a password. Only those management applications with this community string can view the alarms.

Show 4 more labels / short text on this page
RMON events 107 · Field Description · Descripti on · Commu nity
Page 108 of the Panasonic 470 user manual — Step Action
Page 108 · click to enlarge
Page 108

108 Chapter 6 Configuring RMON using Device Manager

The value of sysUpTime at the time this event entry last generated an event. If this entry does generate any events, this value is zero.

Owner If traps are specified to be sent to the owner, then this is the name of the machine that receives alarm traps.

Creating an event

To create an event:

Step Action

1 In the RmonAlarms dialog box Events tab, click Insert.

The RmonAlarms, Insert Events dialog box opens (Figure 45 "Insert Events dialog box" (page 108)).

Figure 45 Insert Events dialog box

Panasonic 470 — Step Action diagram (page 108)
Fig. 47 · Step Action

2 In the Description field, type a name for the event.

3 Select the type of event you want.

The default setting is log-and-trap. You can set the event type to log to save memory or to snmp-trap to reduce traffic from the switch or for better CPU utilization.

If you select snmp-trap or log-and-trap, you must set trap receivers.

4 Click Insert.

The new event is shown in the Events tab (Figure 46 "New event in the Events tab" (page 108)).

Figure 46 New event in the Events tab

Panasonic 470 — Step Action diagram (page 108)
Fig. 48 · Step Action

Field Description · LastTim eSent

Page 109 of the Panasonic 470 user manual — —End—
Page 109 · click to enlarge
Page 109

RMON Log information 109

—End—

Deleting an event

To delete an event:

Step Action

1 In the Events tab, highlight an event Description.

2 Click Delete.

The event is removed from the table.

—End—

RMON Log information

The Log tab chronicles and describes the alarm activity, which is then generated to be viewed.

To view the Log tab:

Step Action

1 From the Device Manager main menu, choose Rmon > Alarms.

The RmonAlarm dialog box opens with the Alarms tab displayed (Figure 43 "RmonAlarms dialog box -- Alarms tab" (page 104)).

2 Click the Log tab.

The Log tab opens (Figure 47 "Log tab" (page 109)).

Figure 47 Log tab

Panasonic 470 — Step Action diagram (page 109)
Fig. 49 · Step Action

—End—

Page 110 of the Panasonic 470 user manual — —End—
Page 110 · click to enlarge
Page 110

110 Chapter 6 Configuring RMON using Device Manager

Table 47 "Log tab fields" (page 110) describes the Log tab fields.

Table 47 Log tab fields

Time An implementation-dependent description of the event that activated the log entry.

Description Specifies whether the event is a rising or falling event.

RMON tab for graphing ports

The RMON tab displays Ethernet statistics for graphing a port or ports.

To open the RMON tab for graphing:

Step Action

1 Select the port or ports you want to graph.

To select multiple ports, [Ctrl] + left-click the ports that you want to configure. A yellow outline appears around the selected ports.

2 Do one of the following:

  • From the Device Manager main menu, choose Graph > Port.
  • From the shortcut menu, choose Graph.
  • On the toolbar, click Graph.

The Port dialog box for a single port or for multiple ports opens with the Interface tab displayed.

3 Click the RMON tab.

The RMON tab for graphing multiple ports opens (Figure 48 "Graph Port dialog box -- RMON tab" (page 111)).

—End—

Item Description

Page 111 of the Panasonic 470 user manual — Figure 48 Graph Port dialog box -- RMON tab
Page 111 · click to enlarge
Page 111

RMON Log information 111

Figure 48 Graph Port dialog box -- RMON tab

Panasonic 470 — Figure 48 Graph Port dialog box -- RMON tab diagram (page 111)
Fig. 50 · Figure 48 Graph Port dialog box -- RMON tab

Table 48 "RMON tab fields" (page 111) describes the RMON tab fields.

Table 48 RMON tab fields

Octets The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets). You can use this object as a reasonable estimate of Ethernet utilization. For greater precision, sample the etherStatsPkts and etherStatsOctets objects before and after a common interval.

Pkts The total number of packets (including bad packets, broadcast packets, and multicast packets) received.

The total number of good packets received that were directed to the broadcast address. Note that this does not include multicast packets.

The total number of good packets received that were directed to a multicast address. Note that this number does not include packets directed to the broadcast address.

The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error).

The total number of packets received that were less than 64 octets long (excluding framing bits but including FCS octets), and were otherwise well-formed.

The total number of packets received that were longer than 1518 octets (excluding framing bits but including FCS octets), and were otherwise well-formed.

Show 6 more labels / short text on this page
Field Description · BroadcastPk ts · MulticastPkt s · CRCAlignErr ors · UndersizePk ts · OversizePkt s
Page 112 of the Panasonic 470 user manual — Figure 48 Graph Port dialog box -- RMON tab
Page 112 · click to enlarge
Page 112

112 Chapter 6 Configuring RMON using Device Manager

Fragments The total number of packets received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error). It is normal for etherStatsFragments to increment because it counts both runts (which are normal occurrences due to collisions) and noise hits.

Collisions The best estimate of the total number of collisions on this Ethernet segment.

Jabbers The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). Jabber is defined as the condition where any packet exceeds 20 ms. The allowed range to detect jabber is between 20 ms and 150 ms.

1..64 The total number of packets (including bad packets) received that were between 1 and 64 octets in length (excluding framing bits but including FCS octets).

65..127 The total number of packets (including bad packets) received that were between 65 and 127 octets in length (excluding framing bits but including FCS octets).

128..255 The total number of packets (including bad packets) received that were between 128 and 255 octets in length (excluding framing bits but including FCS octets).

256..511 The total number of packets (including bad packets) received that were between 256 and 511 octets in length (excluding framing bits but including FCS octets).

511..1023 The total number of packets (including bad packets) received that were between 511 and 1023 octets in length (excluding framing bits but including FCS octets).

1024..1518 The total number of packets (including bad packets) received that were between 1024 and 1518 octets in length (excluding framing bits but including FCS octets).

Field Description

Page 113 of the Panasonic 470 user manual — Step Action
Page 113 · click to enlarge
Page 113

Chapter 7 Configuring RMON using Web-based management

The RMON management information base (MIB) is an interface between the RMON agent on an Ethernet Switch and the RMON management applications such as the Web-based management user interface. It defines objects that are suitable for the management of any type of network. Some groups are specifically targeted for Ethernet networks.

The RMON agent continuously collects statistics and proactively monitors the switch.

This RMON options available to you are:

  • "Configuring RMON fault threshold parameters" (page 113)
  • "Viewing the RMON fault event log" (page 117)
  • "Viewing RMON Ethernet statistics" (page 118)
  • "Viewing RMON history" (page 120)

Configuring RMON fault threshold parameters

Alarms are useful when you need to know when the value of some variable goes out of range. RMON alarms can be defined on any MIB variable that resolves to an integer value. String variables (such as system description) cannot be used as alarm variables.

Creating an RMON fault threshold

You can create the RMON threshold parameters for fault notification (alarms).

To create an RMON threshold:

Step Action

1 From the main menu, choose Fault > RMON Threshold.

Page 114 of the Panasonic 470 user manual — Figure 49 RMON Threshold page
Page 114 · click to enlarge
Page 114

114 Chapter 7 Configuring RMON using Web-based management

The RMON Threshold page opens (Figure 49 "RMON Threshold page" (page 114)).

Figure 49 RMON Threshold page

Panasonic 470 — Figure 49 RMON Threshold page diagram (page 114)
Fig. 51 · Figure 49 RMON Threshold page

Table 49 "RMON Threshold page items" (page 114) describes the items on the RMON Threshold page.

Table 49 RMON Threshold page items

Deletes the row.

1..10 Type the unique number to identify the alarm entry.

Target Integer The unit number and port number.

Unit 1..8 Choose the switch on which to configure port alarms.

Port 1..26 Choose the port on which to set an alarm.

Parameter (1) Good-Bytes (2) Good-Packets (3) Multicast (4) Broadcast (5) CRC-Errors (6) Runts (7) Fragments (8) Frame-Too-Long (9) Collisions

Choose the sampled statistic.

Item Range Description · Index/ Alarm Index

Page 115 of the Panasonic 470 user manual — Figure 49 RMON Threshold page
Page 115 · click to enlarge
Page 115

Configuring RMON fault threshold parameters 115

Integer The value of the statistic during the last sampling period.

Rising Level Integer Type the event entry used when a rising threshold is crossed.

(1) None (2) Log (3) SNMP-Trap (4) Log-and-Trap

Choose the type of notification for the event. Selecting Log generates an entry in the RMON Event Log table for each event. Selecting SNMP Trap sends an SNMP trap to one or more management stations.

Interval Type the time period (in seconds) to sample data and compare the data to the rising and falling thresholds.

(1) Absolute (2) Delta

Choose the sampling method:

Absolute: Absolute alarms are defined on the current value of the alarm variable. An example of an alarm defined with absolute value is card operating status. Because this value is not cumulative, but instead represents states, such as card up (value 1) and card down (value 2), you set it for absolute value. Therefore, an alarm can be created with a rising value of 2 and a falling value of 1 to alert a user to whether the card is up or down.

Delta: Most alarm variables related to Ethernet traffic are set to delta value. Delta alarms are defined based on the difference in the value of the alarm variable between the start of the polling period and the end of the polling period. Delta alarms are sampled twice per polling period. For each sample, the last two values are added together and compared to the threshold values. This process increases precision and allows for the detection of threshold crossings that span the sampling boundary. Therefore, if you keep track of the current values of a

Show 4 more labels / short text on this page
Item Range Description · Current Level · Rising Action · Sample/Alar m Sample
Page 116 of the Panasonic 470 user manual — —End—
Page 116 · click to enlarge
Page 116

116 Chapter 7 Configuring RMON using Web-based management

given delta-valued alarm and add them together, the result is twice the actual value. (This result is not an error in the software.)

2 In the RMON Threshold Creation section, type information in the text boxes, or select from a list.

3 Click Submit.

The new configuration is displayed in the RMON Threshold Table (Figure 49 "RMON Threshold page" (page 114)).

—End—

Deleting an RMON threshold configuration

To delete an existing RMON threshold configuration:

Step Action

1 From the main menu, choose Fault > RMON Threshold.

The RMON Threshold page opens (Figure 49 "RMON Threshold page" (page 114)).

2 In the RMON Threshold Table, click the Delete icon for the entry you want to delete.

A message opens prompting you to confirm your request.

3 Do one of the following:

  • Click Yes to delete the RMON threshold configuration.
  • Click Cancel to return to the RMON Threshold page without making changes.

—End—

Item Range Description

Page 117 of the Panasonic 470 user manual — Viewing the RMON fault event log
Page 117 · click to enlarge
Page 117

Viewing the RMON fault event log 117

Viewing the RMON fault event log

RMON events and alarms work together to notify you when values in your network go outside a specified range. When values pass the specified ranges, the alarm is triggered and fires. The event specifies how the activity is recorded.

An event specifies whether a trap, a log, or a trap and a log are generated to view alarm activity. When RMON is globally enabled, two default events are generated:

  • Rising Event
  • Falling Event

Default events specify that when an alarm goes out of range, the firing of the alarm is tracked in both a trap and a log. For example, when an alarm fires at the rising threshold, the rising event specifies that this information be sent to both a trap and a log. The RMON Event Log page works in conjunction with the RMON Threshold page to enable you to view a history of RMON fault events.

To view a history of RMON fault events:

è From the main menu, choose Fault > RMON Event Log.

The RMON Event Log page opens (Figure 50 "RMON Event Log page" (page 117)).

Figure 50 RMON Event Log page

Panasonic 470 — Viewing the RMON fault event log diagram (page 117)
Fig. 52 · Viewing the RMON fault event log

Table 50 "RMON Event Log page fields" (page 117) describes the fields on the RMON Event Log page.

Table 50 RMON Event Log page fields

Time Stamp Specifies the time that the event occurred.

Description An implementation dependent description of the event that activated this log entry.

Item Description

Page 118 of the Panasonic 470 user manual — Step Action
Page 118 · click to enlarge
Page 118

118 Chapter 7 Configuring RMON using Web-based management

Triggered By Indicates a comment that describes the source of the event.

ID Signifies the event that generated this log entry.

Viewing RMON Ethernet statistics

You can gather and graph RMON Ethernet statistics in a variety of formats.

To gather and graph RMON Ethernet statistics:

Step Action

1 From the main menu, choose Statistics > RMON Ethernet.

The RMON Ethernet page opens (Figure 51 "RMON Ethernet page" (page 118)).

Figure 51 RMON Ethernet page

Panasonic 470 — Step Action diagram (page 118)
Fig. 53 · Step Action

Table 51 "RMON Ethernet page items" (page 118) describes the items on the RMON Ethernet page.

Table 51 RMON Ethernet page items

Port The port number that corresponds to the selected switch.

Drop Events The number of events in which the interface dropped packets due to a lack of resources.

Octets The number of octets of data (including those in bad packets) received on the network (excluding framing bits, but including Frame Check Sequence (FCS) octets).

Item Description · Item Description

Page 119 of the Panasonic 470 user manual — Viewing RMON Ethernet statistics
Page 119 · click to enlarge
Page 119

Viewing RMON Ethernet statistics 119

Packets The number of good packets received that were directed to the broadcast address. This does not include multicast packets.

Broadcast The number of good packets received that were directed to the broadcast address. This does not include multicast packets.

Multicast The number of good packets received that were directed to the multicast address. This does not include packets sent to the broadcast address.

CRC Align Errors The number of packets received during a sampling interval that were between 64 and 1518 octets long that had a bad FCS with either an integral number of octets (FCS Error), or a non-integral number of octets (Alignment Error). The packet length includes Frame Check Sequence (FCS) octets but not framing bits.

Undersize The number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well-formed.

Oversize The number of packets received that were longer than 1518 octets long (excluding framing bits, but including FCS octets) and were otherwise well-formed.

Fragments The number of packets received that were less than 64 octets in length (excluding framing bits, but including FCS octets) and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).

Collisions The "best estimate" number of collisions on this Ethernet segment.

Jabbers The number of packets received that were longer than 1518 octets in length (excluding framing bits, but including FCS octets), and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error).

Packets < = 64 bytes 65-127 bytes 128-255 bytes 256-511 bytes 512-1023 bytes 1024-1518 bytes

The number of octets received (including bad packets) within the specified length (excluding framing bits, but including FCS octets).

2 In the upper-left hand corner, click the unit number of the device to monitor.

3 Click Submit.

The RMON Ethernet Statistics Table is updated with information about the selected device.

4 To refresh statistical information, go to the bottom of the page and click Update, or click Back to return to the Ethernet Statistics page.

Item Description

Page 120 of the Panasonic 470 user manual — Step Action
Page 120 · click to enlarge
Page 120

120 Chapter 7 Configuring RMON using Web-based management

5 To refresh statistical information, click Update, or click Back to return to the Ethernet Statistics page.

—End—

Viewing RMON history

You can view a periodic statistical sampling of data from various types of networks.

To view periodic statistical data:

Step Action

1 From the main menu, choose Statistics > RMON History.

The RMON History page opens (Figure 52 "RMON History page" (page 120)).

Figure 52 RMON History page

Panasonic 470 — Step Action diagram (page 120)
Fig. 54 · Step Action
Page 121 of the Panasonic 470 user manual — Table 52 RMON History page items
Page 121 · click to enlarge
Page 121

Viewing RMON history 121

Table 52 "RMON History page items" (page 121) describes the items on the RMON History page.

Table 52 RMON History page items

Unit Choose the unit number to be monitored. RMON History Statistics (View By) Port Choose the port number to be monitored.

RMON History Statistics Table

Start The value of the sysUPTime at the start of the interval over which this sample was measured.

Drop Events The number of events in which the interface dropped packets due to a lack of resources.

Octets The number of octets of data (including those in bad packets) received on the network (excluding framing bits, but including Frame Check Sequence (FCS) octets).

Packets The number of good packets received that were directed to the broadcast address. This does not include multicast packets.

Broadcast The number of good packets received that were directed to the broadcast address. This does not include multicast packets.

Multicast The number of good packets received that were directed to the multicast address. This does not include packets sent to the broadcast address.

CRC Align Errors The number of packets received during a sampling interval that were between 64 and 1518 octets long that had a bad FCS with either an integral number of octets (FCS Error), or a non-integral number of octets (Alignment Error). The packet length includes Frame Check Sequence (FCS) octets but not framing bits.

Undersize The number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well-formed.

Oversize The number of packets received that were longer than 1518 octets long (excluding framing bits, but including FCS octets) and were otherwise well-formed.

2 In the RMON History Statistics section, choose the unit and port number to be monitored.

3 Click Submit.

Section Item Description

Page 122 of the Panasonic 470 user manual — —End—
Page 122 · click to enlarge
Page 122

122 Chapter 7 Configuring RMON using Web-based management

The RMON History Statistics Table is updated with information about the selected device and port (Figure 52 "RMON History page" (page 120)).

—End—

Page 123 of the Panasonic 470 user manual — Configuring port mirroring
Page 123 · click to enlarge
Page 123

Appendix A Quick steps for port mirroring

If you are a system administrator with experience configuring Ethernet Switch port mirroring, use the flowcharts on the following pages as quick configuration guides. The flowcharts refer you to the configuration rules appropriate for the port mirroring feature.

Configuring port mirroring

To create or modify port mirroring ports, follow the flowcharts in Figure 53 "Configuring port mirroring (1 of 2)" (page 124) and Figure 54 "Configuring port mirroring (2 of 2)" (page 125)).

To open the Port Mirroring Configuration screen:

è Choose Port Mirroring Configuration (or type i) from the Switch Configuration Menu screen

Page 124 of the Panasonic 470 user manual — Figure 53 Configuring port mirroring (1 of 2)
Page 124 · click to enlarge
Page 124

124 Appendix A Quick steps for port mirroring

Figure 53 Configuring port mirroring (1 of 2)

Panasonic 470 — Figure 53 Configuring port mirroring (1 of 2) diagram (page 124)
Fig. 55 · Figure 53 Configuring port mirroring (1 of 2)
Page 125 of the Panasonic 470 user manual — Figure 54 Configuring port mirroring (2 of 2)
Page 125 · click to enlarge
Page 125

Configuring port mirroring 125

Figure 54 Configuring port mirroring (2 of 2)

Panasonic 470 — Figure 54 Configuring port mirroring (2 of 2) diagram (page 125)
Fig. 56 · Figure 54 Configuring port mirroring (2 of 2)
Page 127 of the Panasonic 470 user manual — Table of contents
Page 127 · click to enlarge
Page 127

Table of contents

Configuration — SystemMonitoringp.1Contentsp.7Prefacep.11About this guidep.11Network management tools and interfacesp.11Before you beginp.12Text conventionsp.12Related publicationsp.13Obtaining technical assistancep.14Network monitoringp.15System Logp.15System Log screenp.15Displaying most recent log entry firstp.16Port mirroringp.17Port-based mirroring configurationp.18Address-based mirroring configurationp.19Port mirroring configuration rulesp.21Port Mirroring Configuration screenp.22Port Statistics screenp.25Configuring network monitoring using CLIp.31Setting the system event logp.31Enabling remote loggingp.35show loggingp.35logging remote enable commandp.36no logging remote enable commandp.37logging remote address commandp.37no logging remote address commandp.37logging remote level commandp.38no logging remote level commandp.38default logging remote level commandp.39Using port mirroringp.39show port-mirroring commandp.39port-mirroring commandp.40no port-mirroring commandp.41Displaying port statisticsp.41show port-statistics commandp.42clear-stats commandp.43Configuring network monitoring using Device Managerp.45System Log Settings tabp.45Remote System Log tabp.47Graphing chassis statisticsp.49IP tabp.49ICMP In tabp.53ICMP Out tabp.54Graphing port statisticsp.56Interface tab for graphing portsp.57Ethernet Errors tab for graphing portsp.59Bridge tab for graphing portsp.62Configuring network monitoring using Web-based managementp.65Viewing the system logp.65Configuring port mirroringp.67Viewing system statisticsp.71Viewing port statisticsp.71Viewing all port errorsp.74Viewing interface statisticsp.76Viewing Ethernet error statisticsp.77Viewing transparent bridging statisticsp.79Monitoring MLT trafficp.81Configuring RMON using the CLIp.83show rmon alarmp.83show rmon eventp.84show rmon historyp.84show rmon statsp.85rmon alarmp.86no rmon alarmp.87rmon eventp.88no rmon eventp.88rmon historyp.88no rmon historyp.89rmon statsp.89no rmon statsp.90Configuring RMON using Device Managerp.91Working with RMON informationp.91RMON historyp.92Creating a historyp.92Disabling historyp.94Viewing RMON history statisticsp.94Enabling Ethernet statistics gatheringp.96Disabling Ethernet statistics gatheringp.98RMON Alarmsp.98How RMON alarms workp.98Creating alarmsp.100Alarm Manager examplep.100Viewing RMON statisticsp.103RMON eventsp.106How events workp.106Viewing an eventp.106Creating an eventp.108Deleting an eventp.109RMON Log informationp.109RMON tab for graphing portsp.110Configuring RMON using Web-based managementp.113Configuring RMON fault threshold parametersp.113Creating an RMON fault thresholdp.113Deleting an RMON threshold configurationp.116Viewing the RMON fault event logp.117Viewing RMON Ethernet statisticsp.118Viewing RMON historyp.120Quick steps for port mirroringp.123Configuring port mirroringp.123Indexp.126Figuresp.16Figure 1 System Log screenp.16Figure 2 Port-based mirroring configuration examplep.18Figure 3 Port Mirroring Configuration port-based screen examplep.19Figure 4 Address-based mirroring configuration examplep.20Figure 5 Port Mirroring Configuration address-based screen examplep.21Figure 6 Port Mirror Configuration screenp.22Figure 7 Port statistics screenp.26Figure 8 show logging sort-reverse command outputp.32Figure 9 show logging config command outputp.36Figure 10 show port-mirroring command outputp.39Figure 11 show port-statistics command outputp.43Figure 12 System Log Settings tabp.46Figure 13 Remote System Log tabp.48Figure 14 Graph Chassis dialog box -- Chassis SNMP tabp.50Figure 15 Graph Chassis dialog box -- IP tabp.51Figure 16 Graph Chassis dialog box -- ICMP In tabp.53Figure 17 Graph Chassis dialog box -- ICMP Out tabp.55Figure 18 Interface tab for graphing portsp.57Figure 19 Graph Port dialog box -- Port Ethernet Errors tabp.60Figure 20 Graph Port dialog box -- Bridge tabp.63Figure 21 System Log pagep.66Figure 22 Port Mirroring pagep.68Figure 23 Port pagep.72Figure 24 Port Error Summary pagep.75Figure 25 Interface pagep.76Figure 26 Ethernet Errors pagep.78Figure 27 Transparent Bridging pagep.80Figure 28 Utilization pagep.81Figure 29 show rmon alarm command outputp.84Figure 30 show rmon event command outputp.84Figure 31 show rmon history command outputp.85Figure 32 show rmon stats command outputp.86Figure 33 History tabp.92Figure 34 RmonControl, Insert History dialog boxp.93Figure 35 Rmon History statisticsp.95Figure 36 RmonControl dialog box -- Ether Stats tabp.96Figure 37 RmonControl, Insert Ether Stats dialog boxp.97Figure 38 RmonControl, Insert Ether Stats dialog box port listp.97Figure 39 How alarms firep.99Figure 40 Alarm example -- threshold less than 260p.100Figure 41 Alarm Manager dialog boxp.101Figure 42 Alarm variable listp.102Figure 43 RmonAlarms dialog box -- Alarms tabp.104Figure 44 RmonAlarms dialog box -- Events tabp.107Figure 45 Insert Events dialog boxp.108Figure 46 New event in the Events tabp.108Figure 47 Log tabp.109Figure 48 Graph Port dialog box -- RMON tabp.111Figure 49 RMON Threshold pagep.114Figure 50 RMON Event Log pagep.117Figure 51 RMON Ethernet pagep.118Figure 52 RMON History pagep.120Figure 53 Configuring port mirroring (1 of 2)p.124Figure 54 Configuring port mirroring (2 of 2)p.125Tablesp.16Table 1 System Log screen fieldsp.16Table 2 Port Mirroring Configuration screen fieldsp.23Table 3 Monitoring modesp.24Table 4 Port Statistics screen fieldsp.26Table 5 show logging command parameters and variablesp.32Table 6 logging command parameters and variablesp.33Table 7 set logging command parameters and variablesp.33Table 8 clear logging command parameters and valuesp.35Table 9 show logging command parameters and variablesp.36Table 10 logging remote address command parameters and variablesp.37Table 11 logging remote level command parameters and variablesp.38Table 12 port-mirroring command parameters and variablesp.40Table 13 show port-statistics command parameters and variablesp.42Table 14 clear-stats command parameters and variablesp.44Table 15 System Log Settings tab itemsp.46Table 16 Remote System Log tab itemsp.48Table 17 Chassis IP tab fieldsp.51Table 18 ICMP In tab fieldsp.54Table 19 ICMP Out tab fieldsp.55Table 20 Port Interface tab fields for multiple portsp.58Table 21 Ethernet Errors tab fieldsp.60Table 22 Bridge tab fieldsp.63Table 23 System Log page fieldsp.66Table 24 Port Mirroring page itemsp.68Table 25 Port-based monitoring modesp.70Table 26 Address-based monitoring modesp.71Table 27 Port page itemsp.72Table 28 Port Error Summary Table fieldsp.75Table 29 Interface page itemsp.76Table 30 Ethernet Errors page itemsp.78Table 31 Transparent Bridging page itemsp.80Table 32 Utilization page itemsp.81Table 33 rmon alarm command parameters and variablesp.86Table 34 no rmon alarm command parameters and variablesp.87Table 35 rmon event command parameters and variablesp.88Table 36 no rmon event command parameters and variablesp.88Table 37 rmon history command parameters and variablesp.89Table 38 no rmon history command parameters and variablesp.89Table 39 rmon stats command parameters and variablesp.90Table 40 no rmon stats command parameters and variablesp.90Table 41 History tab fieldsp.93Table 42 Rmon History statistics tab fieldsp.95Table 43 Ether Stats tab fieldsp.97Table 44 Rmon Insert Alarm dialog box fieldsp.103Table 45 Alarms tab fieldsp.104Table 46 Events tab fieldsp.107Table 47 Log tab fieldsp.110Table 48 RMON tab fieldsp.111Table 49 RMON Threshold page itemsp.114Table 50 RMON Event Log page fieldsp.117Table 51 RMON Ethernet page itemsp.118Table 52 RMON History page itemsp.121
Page 128 of the Panasonic 470 user manual — Table of contents
Page 128 · click to enlarge
Page 128

Table of contents

Configuration — SystemMonitoringp.1Contentsp.7Prefacep.11About this guidep.11Network management tools and interfacesp.11Before you beginp.12Text conventionsp.12Related publicationsp.13Obtaining technical assistancep.14Network monitoringp.15System Logp.15System Log screenp.15Displaying most recent log entry firstp.16Port mirroringp.17Port-based mirroring configurationp.18Address-based mirroring configurationp.19Port mirroring configuration rulesp.21Port Mirroring Configuration screenp.22Port Statistics screenp.25Configuring network monitoring using CLIp.31Setting the system event logp.31Enabling remote loggingp.35show loggingp.35logging remote enable commandp.36no logging remote enable commandp.37logging remote address commandp.37no logging remote address commandp.37logging remote level commandp.38no logging remote level commandp.38default logging remote level commandp.39Using port mirroringp.39show port-mirroring commandp.39port-mirroring commandp.40no port-mirroring commandp.41Displaying port statisticsp.41show port-statistics commandp.42clear-stats commandp.43Configuring network monitoring using Device Managerp.45System Log Settings tabp.45Remote System Log tabp.47Graphing chassis statisticsp.49IP tabp.49ICMP In tabp.53ICMP Out tabp.54Graphing port statisticsp.56Interface tab for graphing portsp.57Ethernet Errors tab for graphing portsp.59Bridge tab for graphing portsp.62Configuring network monitoring using Web-based managementp.65Viewing the system logp.65Configuring port mirroringp.67Viewing system statisticsp.71Viewing port statisticsp.71Viewing all port errorsp.74Viewing interface statisticsp.76Viewing Ethernet error statisticsp.77Viewing transparent bridging statisticsp.79Monitoring MLT trafficp.81Configuring RMON using the CLIp.83show rmon alarmp.83show rmon eventp.84show rmon historyp.84show rmon statsp.85rmon alarmp.86no rmon alarmp.87rmon eventp.88no rmon eventp.88rmon historyp.88no rmon historyp.89rmon statsp.89no rmon statsp.90Configuring RMON using Device Managerp.91Working with RMON informationp.91RMON historyp.92Creating a historyp.92Disabling historyp.94Viewing RMON history statisticsp.94Enabling Ethernet statistics gatheringp.96Disabling Ethernet statistics gatheringp.98RMON Alarmsp.98How RMON alarms workp.98Creating alarmsp.100Alarm Manager examplep.100Viewing RMON statisticsp.103RMON eventsp.106How events workp.106Viewing an eventp.106Creating an eventp.108Deleting an eventp.109RMON Log informationp.109RMON tab for graphing portsp.110Configuring RMON using Web-based managementp.113Configuring RMON fault threshold parametersp.113Creating an RMON fault thresholdp.113Deleting an RMON threshold configurationp.116Viewing the RMON fault event logp.117Viewing RMON Ethernet statisticsp.118Viewing RMON historyp.120Quick steps for port mirroringp.123Configuring port mirroringp.123Indexp.126Figuresp.16Figure 1 System Log screenp.16Figure 2 Port-based mirroring configuration examplep.18Figure 3 Port Mirroring Configuration port-based screen examplep.19Figure 4 Address-based mirroring configuration examplep.20Figure 5 Port Mirroring Configuration address-based screen examplep.21Figure 6 Port Mirror Configuration screenp.22Figure 7 Port statistics screenp.26Figure 8 show logging sort-reverse command outputp.32Figure 9 show logging config command outputp.36Figure 10 show port-mirroring command outputp.39Figure 11 show port-statistics command outputp.43Figure 12 System Log Settings tabp.46Figure 13 Remote System Log tabp.48Figure 14 Graph Chassis dialog box -- Chassis SNMP tabp.50Figure 15 Graph Chassis dialog box -- IP tabp.51Figure 16 Graph Chassis dialog box -- ICMP In tabp.53Figure 17 Graph Chassis dialog box -- ICMP Out tabp.55Figure 18 Interface tab for graphing portsp.57Figure 19 Graph Port dialog box -- Port Ethernet Errors tabp.60Figure 20 Graph Port dialog box -- Bridge tabp.63Figure 21 System Log pagep.66Figure 22 Port Mirroring pagep.68Figure 23 Port pagep.72Figure 24 Port Error Summary pagep.75Figure 25 Interface pagep.76Figure 26 Ethernet Errors pagep.78Figure 27 Transparent Bridging pagep.80Figure 28 Utilization pagep.81Figure 29 show rmon alarm command outputp.84Figure 30 show rmon event command outputp.84Figure 31 show rmon history command outputp.85Figure 32 show rmon stats command outputp.86Figure 33 History tabp.92Figure 34 RmonControl, Insert History dialog boxp.93Figure 35 Rmon History statisticsp.95Figure 36 RmonControl dialog box -- Ether Stats tabp.96Figure 37 RmonControl, Insert Ether Stats dialog boxp.97Figure 38 RmonControl, Insert Ether Stats dialog box port listp.97Figure 39 How alarms firep.99Figure 40 Alarm example -- threshold less than 260p.100Figure 41 Alarm Manager dialog boxp.101Figure 42 Alarm variable listp.102Figure 43 RmonAlarms dialog box -- Alarms tabp.104Figure 44 RmonAlarms dialog box -- Events tabp.107Figure 45 Insert Events dialog boxp.108Figure 46 New event in the Events tabp.108Figure 47 Log tabp.109Figure 48 Graph Port dialog box -- RMON tabp.111Figure 49 RMON Threshold pagep.114Figure 50 RMON Event Log pagep.117Figure 51 RMON Ethernet pagep.118Figure 52 RMON History pagep.120Figure 53 Configuring port mirroring (1 of 2)p.124Figure 54 Configuring port mirroring (2 of 2)p.125Tablesp.16Table 1 System Log screen fieldsp.16Table 2 Port Mirroring Configuration screen fieldsp.23Table 3 Monitoring modesp.24Table 4 Port Statistics screen fieldsp.26Table 5 show logging command parameters and variablesp.32Table 6 logging command parameters and variablesp.33Table 7 set logging command parameters and variablesp.33Table 8 clear logging command parameters and valuesp.35Table 9 show logging command parameters and variablesp.36Table 10 logging remote address command parameters and variablesp.37Table 11 logging remote level command parameters and variablesp.38Table 12 port-mirroring command parameters and variablesp.40Table 13 show port-statistics command parameters and variablesp.42Table 14 clear-stats command parameters and variablesp.44Table 15 System Log Settings tab itemsp.46Table 16 Remote System Log tab itemsp.48Table 17 Chassis IP tab fieldsp.51Table 18 ICMP In tab fieldsp.54Table 19 ICMP Out tab fieldsp.55Table 20 Port Interface tab fields for multiple portsp.58Table 21 Ethernet Errors tab fieldsp.60Table 22 Bridge tab fieldsp.63Table 23 System Log page fieldsp.66Table 24 Port Mirroring page itemsp.68Table 25 Port-based monitoring modesp.70Table 26 Address-based monitoring modesp.71Table 27 Port page itemsp.72Table 28 Port Error Summary Table fieldsp.75Table 29 Interface page itemsp.76Table 30 Ethernet Errors page itemsp.78Table 31 Transparent Bridging page itemsp.80Table 32 Utilization page itemsp.81Table 33 rmon alarm command parameters and variablesp.86Table 34 no rmon alarm command parameters and variablesp.87Table 35 rmon event command parameters and variablesp.88Table 36 no rmon event command parameters and variablesp.88Table 37 rmon history command parameters and variablesp.89Table 38 no rmon history command parameters and variablesp.89Table 39 rmon stats command parameters and variablesp.90Table 40 no rmon stats command parameters and variablesp.90Table 41 History tab fieldsp.93Table 42 Rmon History statistics tab fieldsp.95Table 43 Ether Stats tab fieldsp.97Table 44 Rmon Insert Alarm dialog box fieldsp.103Table 45 Alarms tab fieldsp.104Table 46 Events tab fieldsp.107Table 47 Log tab fieldsp.110Table 48 RMON tab fieldsp.111Table 49 RMON Threshold page itemsp.114Table 50 RMON Event Log page fieldsp.117Table 51 RMON Ethernet page itemsp.118Table 52 RMON History page itemsp.121
Page 129 of the Panasonic 470 user manual — Table of contents
Page 129 · click to enlarge
Page 129

Table of contents

Configuration — SystemMonitoringp.1Contentsp.7Prefacep.11About this guidep.11Network management tools and interfacesp.11Before you beginp.12Text conventionsp.12Related publicationsp.13Obtaining technical assistancep.14Network monitoringp.15System Logp.15System Log screenp.15Displaying most recent log entry firstp.16Port mirroringp.17Port-based mirroring configurationp.18Address-based mirroring configurationp.19Port mirroring configuration rulesp.21Port Mirroring Configuration screenp.22Port Statistics screenp.25Configuring network monitoring using CLIp.31Setting the system event logp.31Enabling remote loggingp.35show loggingp.35logging remote enable commandp.36no logging remote enable commandp.37logging remote address commandp.37no logging remote address commandp.37logging remote level commandp.38no logging remote level commandp.38default logging remote level commandp.39Using port mirroringp.39show port-mirroring commandp.39port-mirroring commandp.40no port-mirroring commandp.41Displaying port statisticsp.41show port-statistics commandp.42clear-stats commandp.43Configuring network monitoring using Device Managerp.45System Log Settings tabp.45Remote System Log tabp.47Graphing chassis statisticsp.49IP tabp.49ICMP In tabp.53ICMP Out tabp.54Graphing port statisticsp.56Interface tab for graphing portsp.57Ethernet Errors tab for graphing portsp.59Bridge tab for graphing portsp.62Configuring network monitoring using Web-based managementp.65Viewing the system logp.65Configuring port mirroringp.67Viewing system statisticsp.71Viewing port statisticsp.71Viewing all port errorsp.74Viewing interface statisticsp.76Viewing Ethernet error statisticsp.77Viewing transparent bridging statisticsp.79Monitoring MLT trafficp.81Configuring RMON using the CLIp.83show rmon alarmp.83show rmon eventp.84show rmon historyp.84show rmon statsp.85rmon alarmp.86no rmon alarmp.87rmon eventp.88no rmon eventp.88rmon historyp.88no rmon historyp.89rmon statsp.89no rmon statsp.90Configuring RMON using Device Managerp.91Working with RMON informationp.91RMON historyp.92Creating a historyp.92Disabling historyp.94Viewing RMON history statisticsp.94Enabling Ethernet statistics gatheringp.96Disabling Ethernet statistics gatheringp.98RMON Alarmsp.98How RMON alarms workp.98Creating alarmsp.100Alarm Manager examplep.100Viewing RMON statisticsp.103RMON eventsp.106How events workp.106Viewing an eventp.106Creating an eventp.108Deleting an eventp.109RMON Log informationp.109RMON tab for graphing portsp.110Configuring RMON using Web-based managementp.113Configuring RMON fault threshold parametersp.113Creating an RMON fault thresholdp.113Deleting an RMON threshold configurationp.116Viewing the RMON fault event logp.117Viewing RMON Ethernet statisticsp.118Viewing RMON historyp.120Quick steps for port mirroringp.123Configuring port mirroringp.123Indexp.126Figuresp.16Figure 1 System Log screenp.16Figure 2 Port-based mirroring configuration examplep.18Figure 3 Port Mirroring Configuration port-based screen examplep.19Figure 4 Address-based mirroring configuration examplep.20Figure 5 Port Mirroring Configuration address-based screen examplep.21Figure 6 Port Mirror Configuration screenp.22Figure 7 Port statistics screenp.26Figure 8 show logging sort-reverse command outputp.32Figure 9 show logging config command outputp.36Figure 10 show port-mirroring command outputp.39Figure 11 show port-statistics command outputp.43Figure 12 System Log Settings tabp.46Figure 13 Remote System Log tabp.48Figure 14 Graph Chassis dialog box -- Chassis SNMP tabp.50Figure 15 Graph Chassis dialog box -- IP tabp.51Figure 16 Graph Chassis dialog box -- ICMP In tabp.53Figure 17 Graph Chassis dialog box -- ICMP Out tabp.55Figure 18 Interface tab for graphing portsp.57Figure 19 Graph Port dialog box -- Port Ethernet Errors tabp.60Figure 20 Graph Port dialog box -- Bridge tabp.63Figure 21 System Log pagep.66Figure 22 Port Mirroring pagep.68Figure 23 Port pagep.72Figure 24 Port Error Summary pagep.75Figure 25 Interface pagep.76Figure 26 Ethernet Errors pagep.78Figure 27 Transparent Bridging pagep.80Figure 28 Utilization pagep.81Figure 29 show rmon alarm command outputp.84Figure 30 show rmon event command outputp.84Figure 31 show rmon history command outputp.85Figure 32 show rmon stats command outputp.86Figure 33 History tabp.92Figure 34 RmonControl, Insert History dialog boxp.93Figure 35 Rmon History statisticsp.95Figure 36 RmonControl dialog box -- Ether Stats tabp.96Figure 37 RmonControl, Insert Ether Stats dialog boxp.97Figure 38 RmonControl, Insert Ether Stats dialog box port listp.97Figure 39 How alarms firep.99Figure 40 Alarm example -- threshold less than 260p.100Figure 41 Alarm Manager dialog boxp.101Figure 42 Alarm variable listp.102Figure 43 RmonAlarms dialog box -- Alarms tabp.104Figure 44 RmonAlarms dialog box -- Events tabp.107Figure 45 Insert Events dialog boxp.108Figure 46 New event in the Events tabp.108Figure 47 Log tabp.109Figure 48 Graph Port dialog box -- RMON tabp.111Figure 49 RMON Threshold pagep.114Figure 50 RMON Event Log pagep.117Figure 51 RMON Ethernet pagep.118Figure 52 RMON History pagep.120Figure 53 Configuring port mirroring (1 of 2)p.124Figure 54 Configuring port mirroring (2 of 2)p.125Tablesp.16Table 1 System Log screen fieldsp.16Table 2 Port Mirroring Configuration screen fieldsp.23Table 3 Monitoring modesp.24Table 4 Port Statistics screen fieldsp.26Table 5 show logging command parameters and variablesp.32Table 6 logging command parameters and variablesp.33Table 7 set logging command parameters and variablesp.33Table 8 clear logging command parameters and valuesp.35Table 9 show logging command parameters and variablesp.36Table 10 logging remote address command parameters and variablesp.37Table 11 logging remote level command parameters and variablesp.38Table 12 port-mirroring command parameters and variablesp.40Table 13 show port-statistics command parameters and variablesp.42Table 14 clear-stats command parameters and variablesp.44Table 15 System Log Settings tab itemsp.46Table 16 Remote System Log tab itemsp.48Table 17 Chassis IP tab fieldsp.51Table 18 ICMP In tab fieldsp.54Table 19 ICMP Out tab fieldsp.55Table 20 Port Interface tab fields for multiple portsp.58Table 21 Ethernet Errors tab fieldsp.60Table 22 Bridge tab fieldsp.63Table 23 System Log page fieldsp.66Table 24 Port Mirroring page itemsp.68Table 25 Port-based monitoring modesp.70Table 26 Address-based monitoring modesp.71Table 27 Port page itemsp.72Table 28 Port Error Summary Table fieldsp.75Table 29 Interface page itemsp.76Table 30 Ethernet Errors page itemsp.78Table 31 Transparent Bridging page itemsp.80Table 32 Utilization page itemsp.81Table 33 rmon alarm command parameters and variablesp.86Table 34 no rmon alarm command parameters and variablesp.87Table 35 rmon event command parameters and variablesp.88Table 36 no rmon event command parameters and variablesp.88Table 37 rmon history command parameters and variablesp.89Table 38 no rmon history command parameters and variablesp.89Table 39 rmon stats command parameters and variablesp.90Table 40 no rmon stats command parameters and variablesp.90Table 41 History tab fieldsp.93Table 42 Rmon History statistics tab fieldsp.95Table 43 Ether Stats tab fieldsp.97Table 44 Rmon Insert Alarm dialog box fieldsp.103Table 45 Alarms tab fieldsp.104Table 46 Events tab fieldsp.107Table 47 Log tab fieldsp.110Table 48 RMON tab fieldsp.111Table 49 RMON Threshold page itemsp.114Table 50 RMON Event Log page fieldsp.117Table 51 RMON Ethernet page itemsp.118Table 52 RMON History page itemsp.121
Page 130 of the Panasonic 470 user manual — Table of contents
Page 130 · click to enlarge
Page 130

Table of contents

Configuration — SystemMonitoringp.1Contentsp.7Prefacep.11About this guidep.11Network management tools and interfacesp.11Before you beginp.12Text conventionsp.12Related publicationsp.13Obtaining technical assistancep.14Network monitoringp.15System Logp.15System Log screenp.15Displaying most recent log entry firstp.16Port mirroringp.17Port-based mirroring configurationp.18Address-based mirroring configurationp.19Port mirroring configuration rulesp.21Port Mirroring Configuration screenp.22Port Statistics screenp.25Configuring network monitoring using CLIp.31Setting the system event logp.31Enabling remote loggingp.35show loggingp.35logging remote enable commandp.36no logging remote enable commandp.37logging remote address commandp.37no logging remote address commandp.37logging remote level commandp.38no logging remote level commandp.38default logging remote level commandp.39Using port mirroringp.39show port-mirroring commandp.39port-mirroring commandp.40no port-mirroring commandp.41Displaying port statisticsp.41show port-statistics commandp.42clear-stats commandp.43Configuring network monitoring using Device Managerp.45System Log Settings tabp.45Remote System Log tabp.47Graphing chassis statisticsp.49IP tabp.49ICMP In tabp.53ICMP Out tabp.54Graphing port statisticsp.56Interface tab for graphing portsp.57Ethernet Errors tab for graphing portsp.59Bridge tab for graphing portsp.62Configuring network monitoring using Web-based managementp.65Viewing the system logp.65Configuring port mirroringp.67Viewing system statisticsp.71Viewing port statisticsp.71Viewing all port errorsp.74Viewing interface statisticsp.76Viewing Ethernet error statisticsp.77Viewing transparent bridging statisticsp.79Monitoring MLT trafficp.81Configuring RMON using the CLIp.83show rmon alarmp.83show rmon eventp.84show rmon historyp.84show rmon statsp.85rmon alarmp.86no rmon alarmp.87rmon eventp.88no rmon eventp.88rmon historyp.88no rmon historyp.89rmon statsp.89no rmon statsp.90Configuring RMON using Device Managerp.91Working with RMON informationp.91RMON historyp.92Creating a historyp.92Disabling historyp.94Viewing RMON history statisticsp.94Enabling Ethernet statistics gatheringp.96Disabling Ethernet statistics gatheringp.98RMON Alarmsp.98How RMON alarms workp.98Creating alarmsp.100Alarm Manager examplep.100Viewing RMON statisticsp.103RMON eventsp.106How events workp.106Viewing an eventp.106Creating an eventp.108Deleting an eventp.109RMON Log informationp.109RMON tab for graphing portsp.110Configuring RMON using Web-based managementp.113Configuring RMON fault threshold parametersp.113Creating an RMON fault thresholdp.113Deleting an RMON threshold configurationp.116Viewing the RMON fault event logp.117Viewing RMON Ethernet statisticsp.118Viewing RMON historyp.120Quick steps for port mirroringp.123Configuring port mirroringp.123Indexp.126Figuresp.16Figure 1 System Log screenp.16Figure 2 Port-based mirroring configuration examplep.18Figure 3 Port Mirroring Configuration port-based screen examplep.19Figure 4 Address-based mirroring configuration examplep.20Figure 5 Port Mirroring Configuration address-based screen examplep.21Figure 6 Port Mirror Configuration screenp.22Figure 7 Port statistics screenp.26Figure 8 show logging sort-reverse command outputp.32Figure 9 show logging config command outputp.36Figure 10 show port-mirroring command outputp.39Figure 11 show port-statistics command outputp.43Figure 12 System Log Settings tabp.46Figure 13 Remote System Log tabp.48Figure 14 Graph Chassis dialog box -- Chassis SNMP tabp.50Figure 15 Graph Chassis dialog box -- IP tabp.51Figure 16 Graph Chassis dialog box -- ICMP In tabp.53Figure 17 Graph Chassis dialog box -- ICMP Out tabp.55Figure 18 Interface tab for graphing portsp.57Figure 19 Graph Port dialog box -- Port Ethernet Errors tabp.60Figure 20 Graph Port dialog box -- Bridge tabp.63Figure 21 System Log pagep.66Figure 22 Port Mirroring pagep.68Figure 23 Port pagep.72Figure 24 Port Error Summary pagep.75Figure 25 Interface pagep.76Figure 26 Ethernet Errors pagep.78Figure 27 Transparent Bridging pagep.80Figure 28 Utilization pagep.81Figure 29 show rmon alarm command outputp.84Figure 30 show rmon event command outputp.84Figure 31 show rmon history command outputp.85Figure 32 show rmon stats command outputp.86Figure 33 History tabp.92Figure 34 RmonControl, Insert History dialog boxp.93Figure 35 Rmon History statisticsp.95Figure 36 RmonControl dialog box -- Ether Stats tabp.96Figure 37 RmonControl, Insert Ether Stats dialog boxp.97Figure 38 RmonControl, Insert Ether Stats dialog box port listp.97Figure 39 How alarms firep.99Figure 40 Alarm example -- threshold less than 260p.100Figure 41 Alarm Manager dialog boxp.101Figure 42 Alarm variable listp.102Figure 43 RmonAlarms dialog box -- Alarms tabp.104Figure 44 RmonAlarms dialog box -- Events tabp.107Figure 45 Insert Events dialog boxp.108Figure 46 New event in the Events tabp.108Figure 47 Log tabp.109Figure 48 Graph Port dialog box -- RMON tabp.111Figure 49 RMON Threshold pagep.114Figure 50 RMON Event Log pagep.117Figure 51 RMON Ethernet pagep.118Figure 52 RMON History pagep.120Figure 53 Configuring port mirroring (1 of 2)p.124Figure 54 Configuring port mirroring (2 of 2)p.125Tablesp.16Table 1 System Log screen fieldsp.16Table 2 Port Mirroring Configuration screen fieldsp.23Table 3 Monitoring modesp.24Table 4 Port Statistics screen fieldsp.26Table 5 show logging command parameters and variablesp.32Table 6 logging command parameters and variablesp.33Table 7 set logging command parameters and variablesp.33Table 8 clear logging command parameters and valuesp.35Table 9 show logging command parameters and variablesp.36Table 10 logging remote address command parameters and variablesp.37Table 11 logging remote level command parameters and variablesp.38Table 12 port-mirroring command parameters and variablesp.40Table 13 show port-statistics command parameters and variablesp.42Table 14 clear-stats command parameters and variablesp.44Table 15 System Log Settings tab itemsp.46Table 16 Remote System Log tab itemsp.48Table 17 Chassis IP tab fieldsp.51Table 18 ICMP In tab fieldsp.54Table 19 ICMP Out tab fieldsp.55Table 20 Port Interface tab fields for multiple portsp.58Table 21 Ethernet Errors tab fieldsp.60Table 22 Bridge tab fieldsp.63Table 23 System Log page fieldsp.66Table 24 Port Mirroring page itemsp.68Table 25 Port-based monitoring modesp.70Table 26 Address-based monitoring modesp.71Table 27 Port page itemsp.72Table 28 Port Error Summary Table fieldsp.75Table 29 Interface page itemsp.76Table 30 Ethernet Errors page itemsp.78Table 31 Transparent Bridging page itemsp.80Table 32 Utilization page itemsp.81Table 33 rmon alarm command parameters and variablesp.86Table 34 no rmon alarm command parameters and variablesp.87Table 35 rmon event command parameters and variablesp.88Table 36 no rmon event command parameters and variablesp.88Table 37 rmon history command parameters and variablesp.89Table 38 no rmon history command parameters and variablesp.89Table 39 rmon stats command parameters and variablesp.90Table 40 no rmon stats command parameters and variablesp.90Table 41 History tab fieldsp.93Table 42 Rmon History statistics tab fieldsp.95Table 43 Ether Stats tab fieldsp.97Table 44 Rmon Insert Alarm dialog box fieldsp.103Table 45 Alarms tab fieldsp.104Table 46 Events tab fieldsp.107Table 47 Log tab fieldsp.110Table 48 RMON tab fieldsp.111Table 49 RMON Threshold page itemsp.114Table 50 RMON Event Log page fieldsp.117Table 51 RMON Ethernet page itemsp.118Table 52 RMON History page itemsp.121
Page 131 of the Panasonic 470 user manual — Index
Page 131 · click to enlarge
Page 131
Page 131 of the Panasonic 470 user manual — Index
Page 132 of the Panasonic 470 user manual — Index
Page 132 · click to enlarge
Page 132

Copyright © 2005-2007 , Nortel Networks All Rights Reserved.

PublicationNN47210-503 Document status: Standard Document version: 01.01 Document date: 22 February 2007

To provide feedback or report a problem in this document, go to www.nortel.com/documentfeedback

Sourced in Canada and the United States of America.

The information in this document is subject to change without notice. Nortel Networks reserves the right to make changes in design or components as progress in engineering and manufacturing may warrant.

*Nortel, Nortel Networks, the Nortel log, and the Globemark are trademarks of Nortel Networks.

Ask about the Panasonic 470

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Panasonic 470

Be the first to ask — other owners or our team will answer.

Original document

Panasonic 470 manual PDF

132 pages·3.5 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…