OutBack Power Systems FLEXware is a system of modular aluminum mounting hardware and installation components designed for convenient system installation and integration.
About OutBack Power Systems OutBack Power Systems is a leader in advanced energy conversion technology. Our products include true sine wave inverter/chargers, a maximum power point charge controller, system communication components, as well as breaker panels, breakers, accessories, and assembled systems.
Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING, OUTBACK POWER SYSTEMS: (a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION. (b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK.
Date and Revision November 1, 2006 1.0
Contact Information OutBack Power Systems 19009 62nd Ave. NE Arlington, WA 98223 Phone (360) 435-6030 Fax (360) 435-6019 www.outbackpower.com

The OutBack FLEXware 500 enclosures (FW500-AC and FW500-DC) are listed by ETL as indoor
enclosures to UL standard UL 508A Industrial Control Panels.
This enclosure is intended for battery circuits configured for 12 to 48 volts nominal.
Grounding Instructions – Each enclosure should be connected to a grounded, permanent wiring
system. For most installations, the negative battery conductor should be bonded to the grounding
system at one (and only one) point in the DC system. All installations must comply with all national
and local codes and ordinances. System grounding as required by the National Electric Code, ANSI
/NFPA 70-1996, is the responsibility of the system installer.
The equipment ground on FLEXware 500 is marked with this symbol:
FLEXware is designed for indoor mounting only with appropriate fasteners and a secure mounting
surface that can handle the full weight of an assembled system.

FLEXware is a convenient all-aluminum power system offering simpler, code-compliant installation
of OutBack power electronics components. Three versions of FLEXware are available:
both split-phase and/or higher power output as needed
FW-X240 Auto-Transformers, multiple DC shunts and other essential components required in
higher kW systems.
DC disconnects


AC Breakers ACA FX (with DCC) DCA
IOB Kit FW500-AC FW Mounting Plate DC Breakers MX60 DC FW500-DC Disconnect Breaker
mounting space is limited)
side—are shown in Figure 1.
MX60s


Front View · Side View

A complete FLEXware 500 System consists of the following in addition to the FW500-AC
and FW500-DC:
Some systems will work optimally with an FW-X240 Auto-Transformer installed.
installation is different, consult with your dealer or installer for further information.
FLEXware 500 consists of the FW500-AC and FW500-DC. Each is an aluminum chassis for mounting
AC and DC breakers, respectively, along with the components listed below:
FW500-DC components:
FW500-AC components:
(conduit runs between the FW500-AC
and FW500-DC as needed)
FW500-AC and FW500-DC · per installation

the FLEXware Mounting Plates.
than one.
MX Charge Controller to it.
first. Do not remove any breaker knockouts from these brackets without referring to the chosen
AC IOB kits and DC breaker selections first.
FLEXware 500 is designed for mounting on the FLEXware Mounting Plate (FW-MP). Although the
components can be secured to other surfaces, the FW-MP is an engineered platform designed
for the FLEXware 500 installation. This manual illustrates such an installation. OutBack does not
endorse other installation methods and therefore cannot recommend fasteners or other means of
attachment due to the variety of installations possible in the field.
Please see the FLEXware Mounting Plate Instructions for further information.
In addition to installing the AC and DC chassis, a typical installation includes two FX Series
Inverter/Chargers, an MX60 Charge Controller, a HUB Communications Manager, and AC and DC
conduit adapters. The installation of these components is also displayed in these instructions.


With the Mounting Plate and the hanging screws (for the FX Inverter/Chargers) inserted,
install the FXs.
them when all four are installed and the FX is aligned.

AC side DC side


After the FXs are installed, mount the AC chassis and the DC chassis in either order.

from both the AC and DC
chassis before installing either
of them. If needed, the back
knockouts must be removed
before installation.
When installing the AC chassis and the DC chassis:
appropriate side knockouts · side knockouts

To install the chassis:
only enough to keep the chassis in place.
AC side DC side
AC Chassis Mounting Holes
DC Chassis Mounting Holes

Corrugated Conduit installs between the chassis

With each chassis loosely mounted, the AC Conduit Adapter (ACA) and DC Conduit Adapter (DCA)
are installed on each FX.

DC Wiring Cover (DCC)
Clear plastic AC cover
AC Conduit Plate

to allow for movement) so the DCA lines up with the conduit adapter hole on the chassis.
bushing installed.
screws against the FW-MP.
A single screw holds each DCA conduit adapter in place. Slide the DC chassis against each DCA
and line it up with the plastic bushing.



Plastic bushing, DC side
installation.
To install an ACA:
removed knockout, sliding the AC chassis against the ACAs until snug.

Each ACA fits against the AC chassis

With both the AC Chassis and DC Chassis installed, the breaker brackets, AC din rail(s), and
optional AC and DC breakers can be installed. Please see the individual Input/Output/Bypass
Breaker (IOB) kit for instructions.

A FLEXware 500 System will normally have up to two MX Charge Controllers installed on the
FW500-DC. The chassis accommodates both side and top installation. Newer MXs have rear
knockouts allowing them to be mounted directly to the side of the enclosure without the need for
additional mounting brackets. Mounting brackets are available for top installation of all MX models
and for side installation less recent models.

Bracket screw locations are shown below
Screw locations for directly attaching an MX Charge Controller are shown below
Figure 13:
MX Charge Controller mounting options



Figure 13:
MX Charge Controller 1” knockouts
The MX Charge Controller attaches
to the chassis using three #10 X 3/8”
sheet metal screws included in the
hardware kit. Two are inserted from
inside the MX and the third through
the hanger on the top of the MX.
MX Knockouts · Charge Controller knockouts

An OutBack HUB allows the FX Series Inverter/Chargers, MX60 Charge Controllers, and MATE to
communicate with each other. It attaches to the outside of the FW500-AC (hardware included
with the HUB).

HUB connection









Please take a moment to register and provide us with some important information. Send to:
OutBack Power Systems, 19009 62nd Avenue NE, Arlington, WA 98223 USA.


19009 62nd Avenue NE Arlington, WA USA (+1) 360-435-6030
Barcelona, España (+34) 600-843-845
European Sales Office · 900-0061-1
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.