INSTALLATION INSTRUCTIONS

– Split system air conditioner –

This air conditioner uses the new refrigerant R410A.

DECLARATION OF CONFORMITY

Model Combinations Combine indoor and outdoor units only as listed below.

EG

This product is marked as it satisfies Directives:

COOLING ONLY MODELS Indoor Units Outdoor Units SAP-UR94E SAP-CR94E

– Low voltage no. 73/23 EEC and 93/68 EEC. – Electromagnetic compatibility no. 89/336 ECC, 92/31 EEC

and 93/68 EEC. This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation and/or operating instructions.

F

SAP-UR124E SAP-CR124E

SAP-UR184E SAP-CR184EA SAP-CLR184EA

D

E

SAP-UR224E SAP-CR224EA

COOLING ONLY MODELS

HEAT PUMP MODEL Indoor Units Outdoor Units SAP-UR94EH SAP-CR94EH

P

OPERATING LIMITS Maximum conditions

Outdoor temperature : 43°C D.B. Room temperature : 32°C D.B. / 23°C W.B.

GR

SAP-UR124EH SAP-CR124EH

Outdoor temperature : 19°C D.B. Room temperature : 19°C D.B. / 14°C W.B.

SAP-UR184EH SAP-CR184EHA

SAP-UR224EH SAP-CR224EHA

HEAT PUMP MODELS

OPERATING LIMITS Cooling Maximum conditions

Outdoor temperature : 43°C D.B. Room temperature : 32°C D.B. / 23°C W.B.

Cooling Minimum conditions

Outdoor temperature : 19°C D.B. Room temperature : 19°C D.B. / 14°C W.B.

Heating Maximum conditions

Outdoor temperature : 24°C D.B. / 18°C W.B. Room temperature : 27°C D.B.

Heating Minimum conditions

Outdoor temperature : –8°C D.B. / –9°C W.B.

ACCESSORIES SUPPLIED WITH THE UNIT

PARTSFIGUREQ.TYPARTSFIGUREQ.TY RAWL PLUG2TAPPING SCREW 3,5 X 132 RECEIVER WITH CABLE (5 mt)1DRAIN ELBOW *1 REMOTE CONTROL UNIT1DRAIN CAP *2 AAAALKALINE BATTERY2HEX WRENCH *1 TAPPING SCREW 4 X 302* Outdoor unit

Tools required for installation (not supplied)

1.Standard screwdriver

19. Hammer

2.Phillips head screwdriver

10. Drill

3.Knife or wire stripper

11. Tube cutter

4.Tape measure

12. Tube flaring tool

5.Level

13. Torque wrench

6.Sabre saw or key hole saw

14. Adjustable wrench

7.Hacksaw

15. Reamer (for reburring)
8. Core bits ø 5
16. Hex. key

37.4196.087.0 02/2006

Minimum conditions

Page 2 of the Orion TRUE user manual — WARNING
Page 2 · click to enlarge
Page 2

IMPORTANT! Please read before installation

  • Ground the unit following local electrical codes.
  • The Yellow/Green wire cannot be used for any connection different from the ground connection.
  • Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.
  • Do not allow wiring to touch the refrigerant tubing, compressor, or any moving parts of the fan.
  • Do not use multi-core cable when wiring the power supply and control lines. Use separate cables for each type of line.

This air conditioning system meets strict safety and operating standards. For the installer or service person, it is important to install or service the system so that it operates safely and efficiently.

EG

  • For safe installation and trouble-free operation, you must:
  • Carefully read this instruction booklet before beginning.
  • Follow each installation or repair step exactly as shown.
  • Observe all local, state and national electrical codes.
  • Pay close attention to all warning and caution notices given in this manual.
  • The unit must be supplied with a dedicated electrical line.

When transporting Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminium fins on the air conditioner can cut your fingers.

WARNING

When installing In a room Properly insulate any tubing run inside a room to prevent "sweating", which can cause dripping and water damage to walls and floors.

This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.

... In moist or uneven locations Use a raised concrete base to provide a solid level foundation for the outdoor unit. This prevents damage and abnormal vibrations.

CAUTION

This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.

... In area with strong winds Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

If necessary, get help These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sale/service outlet or your certified dealer for additional instructions.

... In a snowy area (for heat pump-type systems) Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

In case of improper installation The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document.

  • When connecting refrigerant tubing
  • Keep all tubing runs as short as possible.
  • Use the flare method for connecting tubing.
  • Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them; screw by hand and then tighten the nut with a torque wrench for a leak-free connection.
  • Check carefully for leaks before starting the test run.

SPECIAL PRECAUTIONS

  • During installation, connect before the refrigerant system and then the wiring one; proceed in the reverse orden when removing the units.

WARNING

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIANS SHOULD ATTEMPT TO WIRE THIS SYSTEM.

  • When servicing
  • Turn the power OFF at the main power board before opening the unit to check or repair electrical parts and wiring.
  • Keep your fingers and clothing away from any moving parts.
  • Clean up the site after the work, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.
  • Ventilate the room during the installation or testng the refrigeration system; make sure that, after the installation, no gas leaks are present, because this could produce toxic gas and dangerous if in contact with flames or heat-sources.
  • Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked, to ensure the grounding.
  • Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury and death .

When wiring

Page 3 of the Orion TRUE user manual — TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS
Page 3 · click to enlarge
Page 3
  • Installation site selection - Indoor unit AVOID
  • Direct sunlight.
  • Nearby heat sources that may affect unit performance.
  • Areas where leakage of flammable gas may be expected.
  • Locations where large amounts of oil mist may occur (such as in kitchen or near factory equipment) because oil contamination can cause operation problems and may deform plastic surfaces and parts of the unit.
  • Unsteady locations that will cause noise or possible water leakage.
  • Locations where the remote control unit will be splashed with water or affected by dampness or humidity.
  • To make holes in areas where electrical wiring or conduits are located. DO
  • Select an appropriate position from which every corner of the room can be uniformily cooled.
  • Select a sufficiently strong location to support the weight of the unit.
  • Select a location where tubing and drain hose have the shortest run to the outside.
  • Allow access for operation and maintenance as well as unrestricted air flow around the unit.
  • Installation site selection - Outdoor unit AVOID
  • Heat sources, exhaust fans.
  • Direct sunlight.
  • Damp, humid or uneven locations.
  • To make holes in areas where electrical wiring or conduits are located. DO
  • Choose places as cool as possible and well ventilated.
  • use lug bolts or equal to bolt down the unit, reducing vibration and noise.

EG

ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)

G Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with foamed polyethylene

(min. thickness 8mm).

MODELNARROW TUBELARGE TUBE OUTER DIAMETERMIN. THICKNESSOUTER DIAMETERMIN. THICKNESS UR9X - UR12X6,35 mm0,8 mm9,52 mm0,8 mm UR18X6,35 mm0,8 mm12,7 mm0,8 mm UR22X6,35 mm0,8 mm15,88 mm1 mm

G PVC pipe for condensate drain pipe (ø int.18mm) in lenght suitable to let the condensate flow into the outside drainage.

G Anti-freeze oil for flare connections (about 30g.).

G Electric wire: use insulated copper wires of size and length as shown in the table “ELECTRICAL DATA” and at paragraph “SYSTEM WIRING

DIAGRAMS”.

ELECTRICAL DATA

LENGTH, WIRE SIZE AND DELAYED FUSE

MODELPower supply wiring length (A) m2 mmPower line length (B) m2 mmControl line length (C) m2 mmDelayed fuse CR9X8028021600,7510 A 1403,51403,5 CR12X5025021600,7510 A 903,5903,5 CR/CLR18X222,5302,5302,520 A CR22X162,5302,5302,520 A

TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS

MODELMAX. ALLOWABLE TUBING LENGTH AT SHIPMENT (m)LIMIT OF TUBING LENGTH (m)LIMIT OF ELEVATION DIFFERENCE H (m)REQUIRED AMOUNT OF ADDITIOONAL REFRIGERANT (g / m)* UR9X7,515715 UR12X7,520725 UR18X - 22X7,530725

* For every meter of tube more than standard lenght at shipment, add refrigerant as shown in the table. No additional charge of compressor oil is necessary.

(go on page 4)

Page 4 of the Orion TRUE user manual — ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
Page 4 · click to enlarge
Page 4
Page 4 of the Orion TRUE user manual — ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)

Ask about the Orion TRUE

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Orion TRUE

Be the first to ask — other owners or our team will answer.

Original document

Orion TRUE manual PDF

52 pages·2.8 MB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…