EN
OPTI-UPS logo
Official user manual

OPTI-UPS UPS (CS530B)

1 pages·202 KB·Power Supply·PDF·ENDEFRITNLJA
OPTI-UPS UPS (CS530B)
Table of Contents 20 sections Series Standby UPS · Series · For stylish home and office · CS385 / CS530B / CS730B / CS500B · … ShowHide
Page 1 of the OPTI-UPS UPS (CS530B) user manual — Bypass
Page 1 · click to enlarge
Page 1

Series Standby UPS

OPTI-UPS UPS (CS530B) — Series Standby UPS diagram (page 1)
Fig. 1 · Series Standby UPS

Series

For stylish home and office

CS385 / CS530B / CS730B / CS500B

Line Interactive

CS385

CS530B

UPS Series On Line UPS

CS730B

* CS385B / CS530B / CS730B

CS385B / CS530B / CS730B

* Fully digitized microprocessor control * Energy saving (UPS sleep mode ) * 50/60Hz frequency auto sensing * Buzzer can be muted by pressing “ON/OFF” button * Single PCB with reliable design * Clear LED alarms * Cold start (DC power on)

* Short circuit and overload protection * Advanced battery management (ABM) * Automatic diagnostics & battery check * Surge protection of all outlets * EMI/RFI noise filter

Series AVR Series Networking

NEMA 5-15 Only

Rear Panel

Model NameCS 385BCS 530BCS 730B OUTPUT 385VA530VA

CS385B

OPTI-UPS UPS (CS530B) — CS385B diagram (page 1)
Fig. 2

NEMA 5-15R UPS x 2, Bypass x 2

Breaker

Voltage (on battery*) Frequency (on battery) Transfer Time INPUT Voltage (single phase) Frequency PROTECTION Unit Input Overload Protection

Simulated sine wave at 100V / 115V / 220V / 240V < +/- 5% AVR controlled by PWM

Battery Backup

50 or 60Hz +/- 0.3 Hz < 10 milliseconds, including detection time

Series Inverter Series Surge Series Green Power

100V +/- 20%, 110V +/- 25% 220V / 230V / 240V, 170V~280 at line input 50 or 60 Hz +/- 10% (auto sensing)

Bypass

Circuit breaker for overload & short circuit protection UPS Automatic shutdown if overload exceeds 105% of nominal at 20 seconds, 120% at 10 seconds, 130% at 3 seconds

Short Circuit Spike Protection BATTERY Type

UPS output cut off immediately

CS530B / CS730B

Sealed, maintenance-free lead acid batteries with 3-5 years

OPTI-UPS UPS (CS530B) — CS530B / CS730B diagram (page 1)
Fig. 3

Breaker

Typical Recharge Time (to 90% of full capacity) Back-up Time

PC with 15” LCD

15. 18 minutes 8 - 12 minutes

Automatic self- test, Over discharge protection, short circuit

Bypass

Battery Backup

PHYSICAL 1.6 (3.52)2.6 (5.72) 95 x 95 x 158 mm INTERFACE

Sends battery low & power failure signals, and receives shutdown signal from computer Detects power failure battery low, Schedules UPS ON / OFF, displays AC input / output power status

Short beeping sound every 4 seconds (Buzzer can be muted by pressing main switch button)

Battery Low UPS Works at Full Load Overload ENVIRONMENT Ambient Operation

Rapid beeping sound every seconds

Long continuous beeping sound every 4 second

3,500 meters max elevation, 0-95% humidity (No-condensing water),0-40 deg C

* See VS1000C on page 6

Show 8 more labels / short text on this page
Thailand, · 460 joules, 2ms · typical life time · 6 hours · Protection · protection by fuse · Continuous beeping sound · Audible Noise

Ask about the OPTI-UPS UPS (CS530B)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.