Operation Manual


Revised August 1993

OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual.
The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to head precautions can result in injury to people or dam- age to the product.
All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product.
The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense.
The abbreviation “PC” means Programmable Controller and is not used as an abbreviation for any- thing else. Visual Aids
The following headings appear in the left column of the manual to help you locate different types of information.
Indicates information of particular interest for efficient and convenient opera- tion of the product.
1, 2, 3...
Indicates lists of one sort or another, such as procedures, precautions, etc.
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permis- sion of OMRON.
No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the informa- tion contained in this publication.


This manual describes the installation and operation of the Support Tool and includes the sections described below. The Support Tool is a software package for creating and managing displays for the NT20M and NT600M Programmable Terminals (PTs).
Please read this manual completely and be sure you understand the information provided before at- tempting to install and operation the Support Tool.
Section 1 provides an overview of Support Tool operation and its operating environment. Basic oper- ating and input methods common to most Support Tool features are covered. The last section, Tool Settings, describes how to set Support Tool operating parameters, which affect overall operation.
Section 2 describes the specific operations used to create displays for Programmable Terminals. Special features include numeral displays, character string displays, lamps, and bar graphs, all of which can be used to display on-screen data transferred to the PT from the PT’s host, and numeral editing and touch switches, both of which can be used to input data on-screen for transfer to the host from the PT.
Section 3 describes how to manage screens as whole units.
Section 4 describes how to manage files.
Section 5 describes how to print screen images.
Section 6 describes the setup and methods for transferring data between the Support Tool and the PT. This section also includes remote operations for deleting screens from the PT.
Section 7 describes the setup and methods for transferring data between the Support Tool and a PROM writer.
The Appendix provides a table of English character codes.

This section outlines the operations of the Support Tool. It includes general operating procedures and installation proce- dures, as well as miscellaneous information, such as the functional limitations when creating screens for older PT mod- els. Refer to the other sections in this manual for details on specific operations. Reference pages are given in this section for many operations.
1-1 Terminology and NT-series Manuals 2 1-2 Using Older Models 2 1-3 System Configuration 3 1-3-1 NT20M and NT600M Support Tool Operations 3 1-3-2 Menu Configuration 3 1-3-3 Support Tool System 4 1-4 Creating a Work Disk 4 1-5 Starting and Exiting 5 1-6 Main Menu 5 1-7 File Selection 6 1-8 Screen Selection 7 1-9 Inputting Screen Comments, File Names, and Titles 10 1-9-1 Screen Comments 10 1-9-2 File Names and Titles 10 1-10 Editing Screens 11 1-11 Inputting Character Strings and Numbers 12 1-12 Basic Operation 13 1-12-1 Cursors 13 1-12-2 Screen Buttons 14 1-12-3 Mouse 14 1-12-4 Positioning Operations 14 1-13 Tool Settings 15 1-14 Environment Settings 16 1-15 Direct Connection 17 1-15-1 Specifying PC Addresses for Direct Connection 18 1-15-2 Direct Connection Information 19

1-1 Terminology and NT-series Manuals
Names of items in this manual related to the NT Series of Programmable Ter- minals and SYSMAC C-series Programmable Controllers are defined next.
Abbreviations The following abbreviations are used in the text.
Reference Manuals The NT20M/NT2000M Series and NT600M Series are covered in the six manuals described below. Actual manual numbers also include suffixes indi- cating the version of the manual.
The NT Series of Programmable Terminals is constantly being improved to better serve the needs of our customers. This manual describes features available for the newest PTs. Not all of these features are available with pre- vious versions of the Host Interface Units and System ROM, as shown in the following table. Refer to your PT’s operation manuals for details on limitations when using older models.
SYSMAC Terminology

The NT20M/NT600M Support Tool is a software package for creating and maintaining display Screens, memory tables, and custom characters (called marks) for the NT20M and NT600M Programmable Terminals. The Support Tool uses a complete system of menus to facilitate operation.
The Support Tool can be used to create and modify screens, memory tables, and marks, and save resulting data as files. Data created on the Support Tool can be transmitted to the NT20M or NT600M Programmable Terminal. In ad- dition, the Support Tool can receive data from a Programmable Terminal, or data created on the Support Tool can be transmitted to a PROM writer. Also, the Support Tool can receive data from PROM writers. The Support Tool can read history records stored in a Programmable Terminal, and save them in files.
File Selection Screen Selection
Copy Delete Print Title Change ROM History Transmit Receive Initial Screen Change Capacity Change Title Tool Settings
Copy Delete Print Attributes Reading from other Files Table Edit Transmit Receive Continuous/Overlapping Screens Check Marks Change Comment Direct Connection Settings
Input String Numeral Display String Display Lamps Touch Switches Bar Graphs Table Editing Numeral Editing Graphics Marks Edit Extended Functions Environment Settings
See page 15 for specific settings.

1-3-3 Support Tool System
It is recommended that you backup the Support Tool either onto floppy disks or onto your hard disk, store the originals (the floppy disks, hereafter referred to as the “master disks”) and use the backup disks (hereafter referred to as the “work disks”) for routine work. The method for backing up onto a hard disk is explained below. If there are any points pertaining to MS-DOS which are unclear, please refer to your MS-DOS manual.
1, 2, 3... 1. Turn on the power to your computer, and start up MS-DOS.
or From the A: drive, it is possible to designate the C: drive directory.
C >CD \NT

This completes the backup. When starting up the next time, change directo- ries to the NT directory and then input “NTM” to start the Support Tool.
1-5 Starting and Exiting
Startup Procedure If working from a floppy, insert the start-up disk into disk drive A and a data disk into disk drive B, then turn on the power. When using a hard disk, first start up MS-DOS from the hard disk, then input NTMreturn from the NT di- rectory. When the Support Tool has started, the following display will appear.

disks from the floppy disk drive or an operation error will result.
Exiting While the Main Menu is displayed, use the Up Key or the Down Key to move the bar cursor to Exit, and then press the Enter Key. The MS-DOS prompt will be displayed. At this point, eject the floppy disks and turn off the power to the computer. Always be sure to follow this procedure when exiting the Sup- port Tool.
When you start up the Support Tool, the Main Menu will displayed and the following items will be available.
Main Menu · Main Menu Items

1-7 File Selection
When you select Edit Screen from the Main Menu, the File Selection Display is displayed. Move the bar cursor to the desired file name and press the En- ter Key, or click the desired file name once to move the bar cursor and then again to open the file.
Each file contains screen data, memory table data (for numeral and charac- ter string tables), and mark data for a maximum of 250 screens for the NT20M or 1,000 screens for the NT600M. When you want to create a new file, select NEW_FILE. The Screen Selection Display will then appear to se- lect from and a file name and title are input when returning to the File Selec- tion Display. Refer to page 10 for name and title input procedures. If you want to modify a file that has already been created, select the file that you want to modify.
The help message area will display the direct connection setting and file size for the file indicated by the bar cursor.
the direct connection setting turned OFF are read when the Tool Settings is set to ON, the screens will be converted to direct connection data. It is not possible to convert from direct connection data to data without direct connec- tion.

The EV4 version of the software can read and edit data created by the EV1. However, once the data is read by the EV4, it no longer can be read or edited by the EV1, even if the file name has not been changed. This occurs because the EV4 expands the data previously saved with the EV1. Before using any EV1 data with the EV4, it is recommended that a backup copy of the EV1 be made.
File Selection Menu

File Operations You can perform file operations by using the function keys while the File Se- lection Display is being displayed.
254. Any files beyond this number cannot be accessed. If this situation occurs, use another data directory. 2. The only items displayed on the File Selection Display are the models and memory capacity that have been set with Tool Settings. For example, if the NT20M is set as the model and 32 KB is set as the memory, then NT600M files and 64 KB or 128KB NT20M files will not be displayed. Use the Memory Capacity Function Key to alter the memory capacity data set in the file.
When you select either NEW_FILE or an existing file from the File Selection Display, the Screen Selection Display is displayed. If you select an existing file, the Screen Listing for that file is displayed. Move the bar cursor to the desired screen and press the Enter Key, or click the desired screen once to move the bar cursor and then again to edit the screen.
Screen numbers may be from 1 to 250 for the NT20M and from 1 to 1,000 for the NT600M. Only screen numbers 1 to 16 are displayed on the first display. Press the Pg Dn Key to see the next display, and the Pg Up Key to see pre- vious display. When creating a new screen, select a screen number for which nothing is displayed under Status in the Screen Listing.
Screen comments can be input for new screens or for changed screens when returning from the Edit Display to the Screen Selection Display. Refer to page 10 for input procedures.


Screen Status Symbols displayed in the status column (A to E, !) express screen attribute settings for the each screen. Symbols displayed in the status column are ex- plained in more detail in the Screen Status box, which is in the lower right-hand corner of the screen.
Symbol Screen status Meaning
(Blank) No data Indicates a screen for which no data has been created.
! Data exists Indicates a screen for which data has been created.
A A: Cont Indicates a parent screen for continuous screens.
A: Ovlp Indicates a parent screen for overlapping screens.
B B: Buzz Continuous sound is set as the buzzer attribute.
B: Beep Intermittent sound is set as the buzzer attribute.
C C: Err History attribute is set.
D D: Bit Bit input attribute is set.
E E: Alrm Alarm attribute is set.
F F:Keypad Indicates a keypad has been set for numeral editing.
G G:Extend Indicates that the backlight has been set to red or that the backlight has been set to flash for the NT20-DT131/DN131.
Screen Selection Display

You can perform screen operations by using the function keys while the File Selection Display is displayed.
Function key Name Function Page
F1 Copy Copies previously created screen data to another screen number. 90
F2 Delete Deletes designated screen data. Can also be used to delete multiple screens, or to delete screens from the Programmable Terminal one screen at a time.
F3 Print Prints designated screen data. Can also be used to print multiple screens.
F4 Attribute Change (ATTRIB)
Sets buzzer attributes, bit inputs, history records, and alarms. 78
F5 Read Loads screen data from other files. The data can include screens, marks, the numeral table, the character string table, I/O comments, and direct connection information.
F6 Transmit (TMX.) Transmits data from the Support Tool to a Programmable Terminal. The data to be transmitted can be a single screen, multiple screens, or a memory table.
F7 Receive (RCV.) Receives data sent from a Programmable Terminal to the Support Tool. The data to be received can be a single screen, multiple screens, or a memory table.
F8 Continuous or Overlapping Screen Creation (Co/Ovl)
Creates Continuous or Overlapping Screens. 75
F9 Marks (MARK) Creates and modifies marks. 82
F10 Next Item (NEXT) Use to change the functions allocated to the function keys. ---
NEXT, F1 Comment Change (CMNT)
Changes screen comments that have previously been set. 92
NEXT, F2 Table Edit (TABLE) Edits memory tables 59
NEXT, F3 Check (CHECK) Checks whether there are any errors in continuous or overlapping screens, and displays or prints the results.
NEXT, F4 Direct Connection (DIRECT)
Sets data area allocations, comments, and other information for use with direct connection operation. This function key appears only if direct connection has been turned ON in the Tool Settings.
NEXT, F10 Previous Item (PREV) Use to change the functions allocated to the function keys. ---
Tags can be used to handle multiple screens simultaneously. For example, several screens can be deleted at the same time by tagging them and then executing Delete from the Screen Selection Display.
Use the following keys to attach or remove tags.

Space Reverses the tag of the screen with the bar cursor.
Tags are indicated by asterisks. By using tags effectively, you can handle multiple screens as a single group.
Screen Selection Operations · 91, 114 · Handling Multiple Screens

1-9 Inputting Screen Comments, File Names, and Titles
Screen comments, file names, and file titles can be input whenever new screens are created or when existing screens are modified. The methods for inputting these are described in this section.
Screen comments can be input or changed when shifting from the Edit Dis- play to the Screen Selection Display. Use the following procedure.
1, 2, 3... 1. Press the Escape Key from the Edit Display after creating a new screen or editing an existing one. A message will appear asking you to confirm returning to the Screen Selection Display.
File names and titles can be input when shifting from the Screen Selection Display to the File Selection Display. Use the following procedure.
1, 2, 3... 1. Press the Escape Key from the Screen Selection Display after creating new screens and/or editing existing ones. A message will appear asking if the new data should be saved.
Data will be saved to the specified file when the Enter Key is pressed for the title input step. The display, however, will not change until the operation is completed, at which time the File Selection Display will appear.

1-10 Editing Screens
If you select a screen number from the Screen Selection Display, the Initial Edit Display will be displayed. If the NT20M has been selected with Tool Set- tings, then the NT20M screen image display area will be shown in the rectan- gular box at the top of the display. If the NT600M has been selected, then the entire display becomes a display area and this box will not appear.

Screen Edit Operations The following operations can be performed on the Edit Display.
Input string (STR IN)
Inputs character strings to be displayed on the screen and sets their display positions and the manner in which they are to be displayed. Character strings input in this way are treated as fixed displays, and their displays cannot be changed while the Programmable Terminal is operating.
Numeral display (NUM DISP)
Sets numeric displays for the screen by designating the numeral table entry to be referenced at the time of display, the display position, and the method of display.
String display (STR DISP)
Sets character string displays for the screen by designating the string table entry to be referenced at the time of display, the display position, and the method of display.
Lamps (LAMP) Sets lamps for the screen by designating the size/shape of lamp areas, numbers, and labels. 40
Touch switches (TOUCH SW)
Sets touch switches for the screen by designating the size of touch switch areas, numbers, and labels.
Bar graphs (BAR GRPH)
Sets bar graphs for the screen by designating the numeral table entry to use, the display positions/directions, and the method of display. The display of percentage calculations is also set.
Table editing (TBL EDIT)
Edits numeral table and character string table contents, and is the same as the table editing operation entered from the Screen Selection Display.
Numeral editing (NUM EDIT)
Creates screens for numeric input via function keys, touch switches, or Expansion I/O Units (32/16 Terminals or Function Key Units (12 keys)) and designates the numeral table to which the input will be written.
Polylines (a broken line made up of one or more line segments) and circles can be created on screen.
Marks (MARK) Creates and modifies marks. 82
Edit (EDIT) Copies, moves, or deletes text or graphics on the screen. 87
Initial Edit Display · Item Function Page · Graphic input (GRAPHIC)


Enables usage of stand-alone operation. In stand-alone operation, screens can be changed from PT touch switches/function keys or from Expansion I/O Units.
Sets data area allocations, comments, and other information for use with direct connection operation. This function key appears only if direct connection has been turned ON in the Tool Settings.
Accesses a modified version of the Tool Settings to enable changing certain Support Tool operating parameters during operation.
While creating data for the NT600M, there may be times when the screen data and the menu box overlap, making it difficult to see what you are doing. In such cases, you cam move or delete the menu box. The grid display can also be turned ON and OFF for either the NT600M or NT20M by pressing the Delete Key as long as grid display has been enabled in the tool settings (See page 15). The display position of the menu box and will change each time you press the Home Key as shown in the following tables.
NT600M with Grid Enabled

NT600M with Grid Disabled
Delete Key inputs Initial 1 2 3
Menu Bottom Top None Bottom
Grid OFF
Delete Key inputs Initial 1 2
Menu Bottom Bottom Bottom
Grid ON OFF ON
Inputting Character Strings You can use the Left, Right, Backspace, Delete, Insert, and Escape Keys when inputting character strings. Their functions are described below.
Moves the cursor to the left.
Moves the cursor to the right.
BS Deletes one character to the left of the cursor.
DEL Deletes one character at the cursor position.
INS Switches between insert mode and overwrite mode.
ESC Cancels character input string and returns to previous operation.
In insert mode, the cursor becomes a flashing rectangle and character strings are inserted at the cursor position. When text is inserted in this way, character strings to the right of the cursor position move to the right.

In overwrite mode, the cursor becomes a reversed rectangle and character strings delete previously input characters at the cursor position.
Inputting Numbers Inputting numbers is basically the same as inputting character strings, except that you cannot change between insert mode and overwrite mode with the Insert Key. The overwrite mode is always used.
The Home Key can be used to change to 0 any numbers previously input, and the Minus (–) Key can be used to change between positive and negative numbers.
Control Key Combinations The Control Key can be used in combination with other keys to move the cur- sor, delete characters, and achieve other operations. These combinations are shown in the following table.
CTRL + S Left Cursor Key
CTRL + D Right Cursor Key
CTRL + E Up Cursor Key
CTRL + X Down Cursor Key
CTRL + R Page Up Key
CTRL + C Page Down Key
CTRL + H Backspace Key
CTRL + G Delete Key
CTRL + I Tab Key
CTRL + M Enter Key
CTRL + [ Escape Key
Several different cursors will appear depending on Support Tool operation. Special cursors are described in the following table.
The arrow cursor is used in combination with the cursor to specify menu items and icons. Refer to page 14 for details on the mouse.
A cup will appear when the Support Tool is accessing data on the disk. When accessing has finished, the arrow cursor will return.
A question mark will appear when the Support Tool is waiting for a Yes/No response from the user. Press the Enter Key or the left mouse button to answer Yes (confirm) or press the Escape Key or right mouse button to answer No (cancel).
A hand and keyboard will appear at the end of processing to request user acknowledgement. Press any key or either mouse button to continue operation.
Keys Same as · Cursor Meaning

1-12-2 Screen Buttons
There are many buttons in the shape of keys that can appear during Support Tool operation. These buttons can be clicked with the mouse to achieve the same operation as the equivalent keyboard keys. Included are the Enter Key (carriage return arrow), Escape Key, cursor keys, PgUp Key, PgDn Key, Space Bar, Shift+Home (clear) Key (one button combining two keys), the Home (clear) Key, and function keys.
A mouse can be connected to the Support Tool and used to input coordinates to specify display positions for text strings or numerals and to create poly- lines, circles, and other graphics.
To use a mouse, connect a two-button mouse to the computer’s mouse con- nector and prepare a level, smooth surface, such as a mouse pad, to operate it on. The mouse can then be used to move labels, the + cursor, and other objects on the screen (see below).
Procedures in this manual are generally written for operation from the key- board. There are, however, often three means to execute an operation, i.e., from the keyboard, using on-screen buttons, and using the mouse and cursor directly. It is generally a matter of preference on which method is used; the results will be the same.
Left Button The left mouse button can be used in place of the Enter Key to achieve the following.
Right Button The right mouse button can be clicked in place of pressing the Escape Key to move backward through processing steps or to cancel an operation.
some operations have been restricted to only keyboard operation for safety. If the software does not respond when a mouse button is pressed, use the key- board instead.
Grid display can be set via the Tool Settings, and grid display and snap-to- grid operation can be set via the Set Environment settings. The grid can be used either to visually align objects on the display or it can be combined with snap-to-grid operation to force objects to be positioned exactly on the grid. Refer to pages 15 and 16 for details.

1-13 Tool Settings
If you start up the Support Tool and select Tool Settings from the Main Menu, the Tool Settings Display will appear.

Contents of Tool Settings
NT Model Sets the model of Programmable Terminal being used.
Memory Size Sets the memory capacity of the Programmable Terminal.
Direct Setting Turns ON and OFF the direct connection operation. Refer to page 17 for details.
Printer Sets the printer model to be used.
Sheet Feeder Sets a sheet feeder for the printer.
Auto Refresh Sets whether or not the screen will be automatically refreshed when you make screen data additions, deletions, or modifications.
Display Grid Controls the grid display. If “TouchSW” is specified, each grid unit will be the size of a touch switch.
Specify the port on the computer to be used to communicate with the PT. If possible, do not specify the same port as the one used for the mouse.
Sets the file name for the work file that is temporarily used by the Support Tool.
Data Directory Sets directory names for saving screen data which is created.
Press the Enter Key when you want to save the contents of the Tool Settings. Then either press the Enter Key again to return to the Main Menu, or press the Escape Key to return to the Tool Settings Display to correct settings.
If you press the Space Key, the tool settings will be changed without being saved to a file, and you will be returned to the Main Menu.
Press the Escape Key to cancel changing tool settings.
Auto Refresh When screen data is added, deleted, or modified with the Support Tool, the screen display may be temporarily disordered. If Auto Refresh is set to “Yes,” then the screen display will be automatically rewritten when you return to the Initial Edit Screen. When creating large amounts of screen data, however, some time may be required for screen refreshing. Auto Refresh can be set to
Name Content · Communication Port · Temporary Directory

“No” to save time. You can manually rewrite the screen by pressing the Tab Key during operation.
Temporary Directory The Support Tool will create a temporary work file when creating screens or transferring data to or from ROM. Most write operations are performed on this temporary file. To increase overall operating speed, this file should be created on your hard disk or in RAM.
Tool Settings File File settings are saved in the root directory for the Support Tool, i.e., the di- rectory from which the Support Tool is started. The file name is NTMSET.ENV. If this file exists in the root directory when the Support Tool is started, the setting in the file will be read and the Support Tool will operate according to them. Tool settings files can be used to eliminate the need to reset tool setting each time the Support Tool is started.
Display Grid A grid can be displayed to aid in positioning objects when creating screens. The Tool Settings can be used to disable the grid or to set its size to 8, 16, or 32 dots. The grid size can also be set to the same size as a touch switch by specifying “TouchSW.” The grid, once enabled, can be turned ON or OFF as desired during operation. Refer to page 12 for details.
A modified version of the Tool Settings can be accessed from the Initial Edit Display. The following display will appear when SET ENV is specified.

Set the PT operating environment as described in the following table.

Display grid No Display grid is not displayed. y g
Display grid is displayed at the specified width. Screen objects can be snapped to the grid if one of these settings is made and the snap ON function is turned ON (see below).
Display grid is displayed at the minimum width for touch switches. This setting is useful to draw lamps to the same size as touch switches. It functions the same way as the other grids.
Off Allows graphics to be drawn and screen objects to be positioned without interference from the grid, i.e., the grid, if displayed, is used only as a visual guide.
On Allows graphics to be drawn and screen object to be positioned only to the intersection points of the grid.
Lamp/touch switch number di l
No Lamp/touch switch numbers or bit addresses are not displayed. display 1/16 1/4 Indicates lamp/touch switch specifications and the allocated lamp/touch switch number or the allocated PC bit on the display at the specified character size.
For example, “LH001015” would be displayed for a lamp display allocated to HR 1015 using direction connection, “TA001012”would be displayed for a touch switch display allocated to AR 1012 using direction connection, L000 would be displayed for lamp #0 when not using direction connection, and T010 would be displayed for touch switch #10.
No Memory table entry numbers are not displayed. y entry number display 1/16 1/4 Indicates the allocated memory table number on the display at the specified character size for numeral displays, character string displays, bar graphs, and numeral editing areas. “N” is also displayed for numeral table entry numbers and “S” is displayed for character string table entry numbers.
The PT can be set for direct connection to an OMRON PC to allow numeral displays, character displays, numeral editing, lamps, touch switches, and bar graphs to be directly connected to specific bits and words in PC memory. Bits can also be set that will change the displayed screen. This is possible only when the NT600M-DT121/DT211 or NT20M-DT121-V1/DT131 PTs and only when a NT600M-LK201 SYSMAC WAY Host Interface Unit is used. Also, either an NT600M-SMR31 or NT20M-SMR31 System ROM must be used in the PT.
The direct connection setting in the Tool Settings greatly affects the operation of the screen functions that read or write PC memory. Although using direc- tion connection will greatly reduce programming burden for the PC, careful preparation is required to coordinate PC memory and programming with the PT settings for direct connection. The general procedure for this is as follows:
1, 2, 3... 1. Design the required PT screens. 2. Allocate PC memory to the function elements of the screens, i.e., those elements that will directly read or write PC memory. Be sure to list spe- cific PC memory addresses, including areas, and to consider numeral table and character string table capacities. 3. Turn ON direct connection operation in the Tool Settings.

Conversion Screen files that were created with direct connection turned OFF can be loaded with direct connection turned ON to convert the screens for use with direct connection. Once files are created for or converted to direct connec- tion, they cannot be loaded with direct connection turned OFF in the Tool Settings and cannot be converted back for use without direct connection.
Indication on Displays Displays on the File Selection Display and the Screen Selection display will indicate whether or not direct connection has been set. If direct connection has been set, “-O” (for OMRON) will be added after the PT model name fol- lowing the “File List” title on the File Selection Display. The help message area on the Screen Selection Display will also indicate whether or not direct connection has been used together with the file size.
The function keys are allocated as shown in the following table when specify- ing bit and word addresses in PC memory. The values in parentheses indi- cate the maximum word address possible for the largest PC memory. Actual memory sizes vary, however, with the model of PC. Refer to your PC’s opera- tion manual for specific limits.
F2 HR (99)
F3 LR (63)
F4 DM (9999)
F5 CNT (1023)
F6 TIM (1023)
F7 CIO, IR, SR (2555) (displayed as I/S)
The areas that can be designated for direct connection are as shown in the following table.
Item Memory unit Designation
Lamps Bit IR, SR (CIO), AR, or LR bit addresses.
DM word address can also be designated with bit specifications Touch switches
bit specifications.
Timers and counters cannot be designated. (See note.)
Numeral display Word IR, SR (CIO), AR, LR, or DM word addresses.
Timer and counter numbers can also be specified to designate PVs Numeral editing specified to designate PVs.
IR, SR (CIO), AR, LR, or DM word addresses.
Timer and counter numbers cannot be specified.
switch will control the status of the specified bit and all other bits in the speci- fied word will be turned OFF (0).

1-15-2 Direct Connection Information
Settings for the direct connection information are made from the extended functions display. Direct connection information settings will not appear on the extended function display unless direct connection is turned ON in the Tool Settings.
Use the following procedure to set the direct connection information settings.
1, 2, 3... 1. Specify EXTEND from the Initial Edit Display. The following display will appear at the bottom of the screen


PT control area Set the address of the first word in the PC to be used to control PT status. This setting must be made. A user comment may also be input if desired.
PT notify area Set the address of the first word in the PC to be used to store PT status. This setting must be made. A user comment may also be input if desired.
Numeral mem. table The contents of the numeral table used in the file can be seen in list form. Data can be input or changed.
String mem. table The contents of the character string table used in the file can be seen in list form. Data can be input or changed.
F-key input/output notify Function keys cannot be set for PTs with touch panels. These settings are not required and will be ignored if input.
Item Setting

This section describes the procedures used to create and check screens and to input screen attributes. The procedures for creating special display characters, called marks, and for controlling screens during stand-alone operation are also pro- vided here.
2-1 Inputting Character Strings 22 2-1-1 New Character Strings 22 2-1-2 Deleting Character Strings 25 2-1-3 Modifying Character Strings 26 2-2 Numeral Displays 28 2-2-1 Normal Numeral Displays 28 2-2-2 Direct Connection Numeral Displays 31 2-3 Character String Displays 34 2-3-1 Normal Character String Displays 35 2-3-2 Direct Connection Character String Displays 37 2-4 Lamps 40 2-4-1 Normal Lamps 40 2-4-2 Direct Connection Lamps 43 2-5 Touch Switches 46 2-5-1 Normal Touch Switches 46 2-5-2 Direct Connection Touch Switches 48 2-6 Bar Graphs 51 2-6-1 Creating Normal Bar Graphs 52 2-6-2 Direct Connection Bar Graphs 55 2-7 Editing Memory Tables 59 2-7-1 Normal Operation 59 2-7-2 Direction Connection Operation 61 2-8 Numeral Editing 62 2-8-1 Normal Numeral Editing 63 2-8-2 Direct Connection Numeral Editing 68 2-8-3 Precautions for Numeral Editing 70 2-9 Polylines 71 2-9-1 Creating New Polylines 71 2-9-2 Deleting Polylines 72 2-9-3 Modifying Polylines 72 2-10 Circles 73 2-10-1 Creating New Circles 73 2-10-2 Deleting Circles 74 2-10-3 Modifying Circles 74 2-11 Continuous and Overlapping Screens 75 2-12 Screen Attributes 78 2-13 Screen Check 80 2-14 Marks 82 2-15 Stand-alone Operation 85 2-16 Edit 87

2-1 Inputting Character Strings
With the Character Input Display, you set characters to be displayed on the PT. You set character sizes, character scaling factors, manner of display, and display positions.
If you select STR IN from the Initial Edit Display, the Initial Character Input Display will appear.
Initial Character Input Display

The following pages explain how to use this display, taking the creation of NT20M screen data as an example.
Inputting Strings This example shows how to input the roman letters “abcde.”
You can display up to 32 characters per line on a NT20M screen, and up to 80 per line on a NT600M screen. 1, 2, 3... 1. Specify CREATE. 2. Input the characters, e.g., “abcde.” The following display will appear.


Special Characters Characters not on the keyboard can be input via character codes. A list of character codes is provided at the end of the manual. To input a character code, press the ALT Key followed by the decimal code.
Marks You can input marks while inputting characters.
1, 2, 3... 1. Press F1 (Mark) while inputting a string. The Mark List will appear.



String Attributes Here you set the size, scale, and attributes for character strings that have been input.

1, 2, 3... 1. Set the size to be used for each 1-byte character. 2. Set the scale factor for the characters. NT600M strings can be set to 64X in addition to the ones shown in the above display. 3. Set display attributes. “Spot” is for flashing characters in reverse video. Display attributes will be displayed on the computer screen as shown below. (Although the contrast of most displays in this manual is re- versed, the contrast of these examples is the same of that on the screen.
Inverse Spot (Inverse Blinking)

A display for designating string position will appear next.
Designate the display position for the string.
1, 2, 3... 1. A rectangular guide box showing the size of the input character string will be displayed. The guide box is displayed according to the number of characters input to that point, and the scale which has been set. Set the display position on the screen with the direction keys. By operating the direction keys while pressing the Shift Key, you can move the guide box 16 dots at a time. The X and Y coordinates of the display position (the X and Y coordinates of the lower left-hand corner of the guide box) are
Normal Flashing · Designating Display Position

displayed. You cannot set a display position that allows the guide box to extend off the screen.


You can delete strings that have already been set by using the procedure given below. When you delete a string, a portion of the display may be left empty. If this happens, press the TAB Key to rewrite the display.
Guide box · Cross-shaped cursor

1, 2, 3... 1. Specify DELETE. The cross-shaped cursor will be displayed.


The basic delete operation for other data on the Edit Display, e.g., numeral displays, is the same.
rescan the display.
You can modify strings that have already been set.

1, 2, 3... 1. Press MODIFY. The cross-shaped cursor will be displayed.


3. Use the Up and Down Keys to select the item to modified, and then press the Enter Key. You can return to step 2 by pressing the Escape Key. For items selected for change, data input methods are the same as when the string was created. 4. To end the modification, press the Escape Key. A message will appear asking whether you want to save the modified contents. 5. Press the Enter Key to save any changes made, or if you do not wish to save the modified contents, press the Space Key to cancel all modifica- tions and restore the previous data. 6. To return to step 3, press the Escape Key.
The procedure for modifying data with the Edit Display is the same as that for other functions such as numeral and character displays.

2-2 Numeral Displays
Values from numeral tables can be displayed on a screen. The numeral table entry to be referenced, the display position, and the manner of display are set. You can set a maximum of 50 numeral displays per screen.
For the NT20M, numeral table entries are numbered from 0 to 127, for a total of 128. For the NT600M, numeral table entries are numbered from 0 to 255, for a total of 256.
The procedure for setting number displays depends on whether or not direct connection is ON or OFF in the Tool Settings. Both procedures are given be- low.
Select NUM DISP from the Initial Edit Display, the Initial Display for Numeral Display will appear.
Initial Display for Numeral Display

Designating Numeral Table References
Only table number entries 0 to 13 are displayed first. To display the next en- tries, press the Pg Dn Key; to return to previous entires, press the Pg Up Key.
Select the numeral table entry that you want to reference and then press the Enter Key.
Inputting Initial Values The initial value for the selected memory table reference is input next. Refer to page 12 for details on input methods. You can input numbers from –99999999 to 99999999. Numeral displays can display decimal numbers, but you enter them here without the decimal point. For example, if you want to

input –123.456, then just input –123456. The distinction between the integer portion and the decimal portion is specified in the next step.

Input the number, and then press the Enter Key.

Set the way in which the display will appear on the screen. Refer to the ex- amples on page 30.
Numeral Display Settings

Reference table entry (Reference Table)
Set the number of the item to be referenced in the numeral table.
Number of integer digits (Integer)
Set the number of digits for the integer portion of the number.
Number of decimal digits (Decimal)
Set the number of digits for the decimal portion of the number.
Zero suppress (Zero Sup)
Set whether or not leading zeros are to be displayed on the screen.
Display sign (Disp Sign)
Set whether or not negative signs are to be displayed on the screen. The positive sign is not displayed.
Character size (Char Size)
Set the size of characters to be displayed on the screen.
Scale Set the scale factor for the display. The NT600M can be set to 64X in addition to those shown above.
Attributes Sets display attributes for the screen. Refer to page 24 for examples of how attributes are displayed on screen.
Press the Enter Key after checking all of these settings.

Numeral Display Examples

A guide box corresponding to the size of the numeral display will appear. Designate the display position on the screen with the cross-shaped cursor and press the Enter Key. You cannot make a setting that will cause the guide box to extend from the screen.

You can delete or modify previously input numeral displays. The procedures for these operations are the same as those for deleting and modifying char- acter strings. Refer to appropriate subsections of 2-1 Inputting Character Strings for details.
Creating Use the following procedure to create a direct connection numeral display.
1, 2, 3... 1. Select NUM DISP from the Initial Edit Display, a list of the numeral dis- plays already existing in the current screen will be displayed.

Designating Display Positions · Deleting and Modifying


No. Numeral table entry number
IN initialize at startup) Indicates whether or not the table value is to be initialized when the PT is turned ON.
# (quantity) Number of PC words used
Word Address of the first PC word
Comment User comment area
Heading Meaning · Contents Initial value

Refer to page 61 for details.

Initialize (Init) Set YES to initialize the contents in the numeral table when PT power is turned ON. Set to NO to maintain the previous value when PT power is turned ON.
Set words (St Word) Set the number of PC words to be used.
Word Set the address of the first PC word to be used.
Comment Input any desired user comment area
The numeral display settings will appear when the above display is left.

Heading Meaning

Number of integer digits (Integer)
Set the number of digits for the integer portion of the number.
Number of decimal digits (Decimal)
Set the number of digits for the decimal portion of the number.
Zero suppress (Zero Sup)
Set whether or not leading zeros are to be displayed on the screen.
Display sign (Disp Sign)
Set whether or not negative signs are to be displayed on the screen. The positive sign is not displayed.
Character size (Char Size)
Set the size of characters to be displayed on the screen.
Scale Set the scale factor for the display. The NT600M can be set to 64X in addition to those shown above.
Attributes Sets display attributes for the screen. Refer to page 24 for examples of how attributes are displayed on screen.
Display type (Disp Type)
Specify either decimal or hexadecimal display.
Press the Enter Key after completing all of these settings. 8. Set the display position. When the display position has been set, you can return to set another numeral display or you can continue pressing the Escape Key to return to the Initial Edit Display.
Deleting and Modifying Direct connection numeral displays are deleted or modified from the display shown in step 1. above. Select the number of the numeral table and then specify DELETE or MODIFY. The modification procedure is basically the same as the creation procedure given above.
The contents of character string tables can be displayed on the screen. The string table entry to be referenced, the display position, and manner of dis- play must be set.
You can set a maximum of 8 string displays per screen for the NT20M and 50 for the NT600M.For the NT20M, string table entries are numbered from 0 to 31, for a total of 32. For the NT600M, string table entries are numbered from 0 to 255, for a total of 256.
The procedure for setting number displays depends on whether or not direct connection is ON or OFF in the Tool Settings. Both procedures are given be- low.

2-3-1 Normal Character String Displays
If you select STR DISP from the Initial Edit Display, the Initial Screen for Character String Display will appear.
Initial Display for Character String Display
Designating String Tables to be Referenced
Table entires 0 to 13 are displayed first on the screen. To display the next entires, press the Pg Dn Key; to return to previously entries, press the Pg Up Key.
Select the string table entry that you want to reference and then press the Enter Key.
Inputting Initial Value Set the initial value for the selected table entry.
Input the initial value according to the instructions for inputting the initial val- ues for numeral tables. For the NT20M, the maximum number of characters that can be registered is 32 characters. For the NT600M, the maximum num- ber of characters that can be registered is 40 characters.

Input the characters, and then press the Enter Key.


Set the way in which the display will appear on the screen.
Number of character digits (Char; See Note)
Set the number of character digits to be displayed on the screen.
Character size (Size) Set the character size to be used for each 1-byte characters.
Scale Set the scale for characters to be displayed on the screen. The NT600M can be set to 64X in addition to those shown above.
Display attributes (Attr.)
Set display attributes for the screen. Refer to page 24 for examples of how attributes are displayed on screen.
have been set will be displayed. Each normal character requires one digit and each mark requires 2 digits.
Press the Enter Key after checking all of the settings.
A guide box corresponding to the size of the set contents will be displayed. Designate the display position on the screen with the cross-shaped cursor Designating Display Position
Setting Display Attributes

and press the Enter Key. You cannot make a setting that will cause the guide box to extend from the screen.

Deleting and Modifying You can delete or modify previously input character string displays. The pro- cedures for these operations are the same as those for deleting and modify- ing character strings. Refer to appropriate subsections of 2-1 Inputting Char- acter Strings for details.
Creating Use the following procedure to create a direct connection character string display.
1, 2, 3... 1. Select STR DISP from the Initial Edit Display, a list of the character string displays already existing in the current screen will be displayed.



No. Character string table entry number
IN (initialize at startup) Indicates whether or not the table value is to be initialized when the PT is turned ON.
# (quantity) Number of PC words used
Word Address of the first PC word
Comment User comment area
Heading Meaning · Contents Initial value

value field is left, the following display will appear to input the remaining settings.

Initialize (Init) Set YES to initialize the contents in the character string table when PT power is turned ON. Set to NO to maintain the previous value when PT power is turned ON.
Set words (St Word) Set the number of PC words to be used.
Word Set the address of the first PC word to be used.
Comment Input any desired user comment area
The character string display settings will appear when the above display is left.

Heading Meaning

Number of character digits (Char; See Note)
Set the number of character digits to be displayed on the screen.
Character size (Size) Set the character size to be used for each 1-byte characters.
Scale Set the scale for characters to be displayed on the screen.
Display attributes (Attr.)
Set display attributes for the screen. Refer to page 24 for examples of how attributes are displayed on screen.
have been set will be displayed. Each normal character requires one digit and each mark requires 2 digits.
Deleting and Modifying Direct connection character string displays are deleted or modified from the display shown in step 1. above. Select the number of the character string table and then specify DELETE or MODIFY. The modification procedure is basically the same as the creation procedure given above.
An indicator lamp can be created by setting the lamp size, display position, and a label. You can set a maximum of 64 lamps per screen for the NT20M and 128 for the NT600M.
The procedure for creating lamps depends on whether or not direct connec- tion is ON or OFF in the Tool Settings. Both procedures are given below.
If you select LAMP from the Initial Edit Display, the Initial Lamp Display will appear.

Lamp Shape Either square or circular must be specified for the lamp shape.
Initial Lamp Display

Designating Area The size and display position of the lamp must be specified. The lamp area is set by designating diagonal corners (the starting and ending points) of a rect- angle for square lamps and the center and radius of circular lamps.
1, 2, 3... 1. Designate the starting point or center. 2. Designate the ending point or radius
The lamp settings are input after the lamp area has been designated.
overlapping sections may not be inverse properly. Frames on lamps and touch switches and labels may also prevent proper display for overlapping lamps/touch switches.

Lamp number The number of the lamp being set. (The numbers, 0 to 255, are used in common with touch switches. The same number cannot be used more than once.)
Frame Whether or not lamp frames are to be displayed when lamps are displayed. If “No” is designated, lamps will be indicated by dotted lines on the Support Tool display.
Attributes Set whether the lamp will light or flash when controlled by bit signals from the host.
This attribute is effective only when controlling the lamp via bit signals from the Host Interface Units that support bit designation. This setting is ignored when controlling lamps via commands, which can be used to control the same attribute.
Label Whether or not a label is to be attached to the lamp.
Press the Enter Key after checking all of these settings. The label is input next if label input has been designated.

Inputting the Label If you set label to “Yes,” the following screen will be displayed. If you set label to “No,” you will be returned to the Initial Lamp Display.

Input the label and press the Enter Key. You can also press the F3 Function Key to input from a list of marks that have been created. Refer to page 22 for details on the mark input procedure.
are required. 2. “@” will be input as the default label if the label setting is changed from NO to YES.
Set the size and scale of the label display.

Position the label on the screen.
Deleting and Modifying You can delete or modify previously input lamp data on the screen. The pro- cedures for these operations are the same as those for deleting and modify- ing character strings. Refer to appropriate subsections of 2-1 Inputting Char- acter Strings for details.

2-4-2 Direct Connection Lamps
Creating Use the following procedure to create a direct connection lamp.
1, 2, 3... 1. Select LAMP from the Initial Edit Display, a list of the lamps already ex- isting in the current screen will be displayed.



nate the center and one point on the circumference of the circle. A dis- play will appear to specify the bit that is to control the lamp.


Frame Whether or not lamp frames are to be displayed when lamps are displayed. If “No” is designated, lamps will be indicated by dotted lines on the Support Tool display.
Attributes Set whether the lamp will light or flash when controlled by bit signals from the host.
This attribute is effective only when controlling the lamp via bit signals from the Host Interface Units that support bit designation. This setting is ignored when controlling lamps via commands, which can be used to control the same attribute.
Label Whether or not a label is to be attached to the lamp.

Press the Enter Key after completing all of these settings. 8. If you set label to “Yes,” the following screen will be displayed. If you set label to “No,” you will be returned to the Initial Lamp Display.

Input the label and press the Enter Key. You can also press the F3 Function Key to input from a list of marks that have been created. Refer to page 22 for details on the mark input procedure. Note 1. Labels can be only one line long. Input character strings if longer labels
are required. 2. “@” will be input as the default label if the label setting is changed from NO to YES. Set the size and scale of the label display.

Position the label on the screen.
When lamp settings have been completed, you can return to set another lamp or you can continue pressing the Escape Key to return to the Initial Edit Display.
Deleting and Modifying Direct connection lamps are deleted or modified from the display shown in step 1. above. Select the number of the numeral table and then specify DE-

LETE or MODIFY. The modification procedure is basically the same as the creation procedure given above.
A touch switch can be set by designating the size, display position, and a label. You can set a maximum of 64 touch switches per screen for the NT20M and 128 for the NT600M.
The procedure for creating touch switches depends on whether or not direct connection is ON or OFF in the Tool Settings. Both procedures are given be- low.
If you select TOUCH SW from the Initial Edit Display, the Initial Touch Switch Display will appear.
Initial Touch Switch Display

Designating Area The size and display position of the touch switch must be specified. The touch switch area is set by designating diagonal corners (the starting and ending points) of a rectangle on a grid.
1, 2, 3... 1. Designate the starting point. 2. Designate the ending point.
The touch switch settings are input after the area has been designated.
switches inverse displays may not be displayed properly.
Starting point · Ending point


The number of the switch being set. (The numbers, 0 to 255, are used in common with lamps. The same number cannot be used more than once.)
Frame Whether or not switch frames are to be displayed when switch are displayed. If “No” is designated, the switches will be indicated by dotted lines on the Support Tool display. Either or normal or solid frame can also be designated.
Inverse Whether an inverse display will appear when the touch switch is input.
Label Whether or not a label is to be attached to the switch.
Press the Enter Key after checking all of these settings. The label is input next if label input has been designated.
Inputting the Label If you set label to “Yes,” the following display will appear. If you set label to “No,” you will be returned to the Initial Touch Switch Display.

Input the label and press the Enter Key. You can also press the F3 Function Key to input from a list of marks that have been created. Refer to page 22 for details on the mark input procedure.
Touch Switch Settings · Switch number

are required. 2. “@” will be input as the default label if the label setting is changed from NO to YES. Set the size and scale of the label display.

Position the label on the screen.
Deleting and Modifying You can delete or modify previously input touch switch data on the screen. The procedures for these operations are the same as those for deleting and modifying character strings. Refer to appropriate subsections of 2-1 Inputting Character Strings for details.
default.
Creating Use the following procedure to create a direct connection touch switch.
1, 2, 3... 1. Select TOUCH SW from the Initial Edit Display, a list of the touch switches already existing in the current screen will be displayed.



4. Input the address of the PC bit that is to control the touch switch. Timer/ counter numbers cannot be specified. DM word address can also be specified, followed by the bit number within the word. 5. Input a comment if desired. The comment is for user use only. 6. Specify the function of the touch switch. The display that appears next will depend on the setting made here. The three possible settings are as follows: Notify : Sends a signal to the PC when the switch is pressed, i.e., turns the specified bit ON while the switch is pressed. SwScreen: Switches to a specified screen when the switch is pressed.
This setting is used for stand-alone operation. Keypad: Creates a key for numeral editing. 7. Notify: Specify the address of the PC bit to be controlled by the touch switch. Timer/counter numbers cannot be specified. A DM word address can be specified followed by the bit number. A user comment can also be input if desired. SwScreen: Specify the number of the screen to be switched to when the touch switch is pressed. The screen number set here will be set in the PT status notify area in the direct connection information. Keypad: Specify the touch switch number to be used for numeral edit- ing.
touch switch status, the status of the specified bit will vary with the status of the touch switch, but all other bits in the specified word will be turned OFF. Timing must be precisely controlled if more than one bit in the same DM word is used for notification to ensure accuracy in reading the status.

The touch switch settings will appear when the above setting has been made.

Frame Whether or not a switch frame is to be displayed when the switch is displayed. If “No” is designated, the switch will be indicated by dotted lines on the Support Tool display. Either or normal or solid frame can also be designated.
Inverse Whether an inverse display will appear when the touch switch is input.
Attributes Specify whether the switch is to light of flash while pressed.
Label Whether or not a label is to be attached to the switch.
Press the Enter Key after completing all of these settings. 9. If you set label to “Yes,” the following screen will be displayed. If you set label to “No,” you will be returned to the Initial Touch Switch Display.

Input the label and press the Enter Key. You can also press the F3 Function Key to input from a list of marks that have been created. Refer to page 22 for details on the mark input procedure.

are required.
Set the size and scale of the label display.

Position the label on the screen.
When touch switch settings have been completed, you can return to set another touch switch or you can continue pressing the Escape Key to return to the Initial Edit Display.
Deleting and Modifying Direct connection touch switches are deleted or modified from the display shown in step 1. above. Select the number of the numeral table and then specify DELETE or MODIFY. The modification procedure is basically the same as the creation procedure given above.
Values from numeral tables can be used to create bar graphs by setting the numeral table entries to be referenced, the display positions, the display style, and the display direction. Bars can also be displayed in the negative direction and the display direction can be reversed.
You can set a maximum of 8 bars per screen for the NT20M and 50 for the NT600M.
The procedure for setting bar graphs depends on whether or not direct con- nection is ON or OFF in the Tool Settings. Both procedures are given below.

2-6-1 Creating Normal Bar Graphs
If you select BAR GRPH from the Initial Edit Display, the Initial Bar Graph Display will appear.
Initial Bar Graph Display

A bar graph is set by designating both ends (the starting and ending points) of a diagonal line across the bar graph. It makes no difference whether the display position of a bar graph is designated from the right or left, or from the top or bottom. The ending point designates only the length (along the X axis) of the bar graph. Whether the bar is vertical or horizontal is designated next in the display settings.
2 bits or 255 dots (set with display setting) BAR GRAPH
1, 2, 3... 1. Designate the starting point. 2. Designate the ending point.
Designating Display Position · Starting point · Ending point

Setting the Numeral Table Reference
Specify the entry number of the numeral table to be referenced for the bar graph.

Inputting Initial Value Set the initial value and then press the Enter Key.


Display Settings Set all the bar graph display attributes and press the Enter Key.

Direction Whether the bar is to be displayed in the normal direction or the reverse direction. (See note 1.)
Width The width of the bar graph. The width must be 3 dots or greater to set a frame. The width must be 8 dots or greater when displaying horizontal bars from the top of the screen or when displaying vertical bars from the right of the screen.
Graph Frame Whether or not a graph frame showing 100% is to be displayed.
Disp sign Whether or not a negative (–) sign is to be displayed. If a negative sign is used, the bar graph can be displayed in the reverse direction for negative values. (See note 2.)
100% value The value of the denominator for percentage calculations. You cannot set numerals of 0 or less as the 100% value.
Display % Whether or not the result of percentage calculations is to be displayed as numerals.
Size of % Set the character size of numerals for when percentages are displayed.
Scale Set the scale factor for the percentage display. The NT600M can be set to 64X in addition to those shown above.
bar graphs can be displayed top to bottom or bottom to top. 2. If a display sign (negative value) is specified, the center of the bar will be set as 0% and the right or top of the bar will be set as 100% (for normal displays). (The center will be one dot up or to the left of center for odd- sized bars.) Examples are shown below.

(Number of display dots) = (Maximum length of graph) x
If the results for a bar graph display is over 100%, a 1-dot blank will be displayed past the size set with the Support Tool and an 8-dot bar will be display beyond the blank to indicate a value over 100% (see below).
1 dot 8 dots
Setting % Display Position If the % Display is set to “Yes,” then the display position is designated. If it is set to “No,” then this screen is not displayed.
Designate the display position of the percentage value.
Deleting and Modifying You can delete or modify previously input bar graph data on the screen. The procedures for these operations are the same as those for deleting and mo- difying character strings. Refer to appropriate subsections of 2-1 Inputting Character Strings for details.
Creating Use the following procedure to create a direct connection bar graph.
1, 2, 3... 1. Select BAR GRPH from the Initial Edit Display, a list of the bar graphs already existing in the current screen will be displayed.

The headings in this list are as follows: No.: The number of the bar graph in the current display.

This is not the numeral table entry number. M Tbl: The numeral table entry number being used. Rf: The access method for the numeral table (direct or indirect) Dr: The direction of the bar. %: Whether or not the percentage display is being used. 2. Specify the number to be used in the table. This is not the numeral table and the numbers do not correspond to item numbers in the numeral table. When the number is specified, a cursor will appear to designate the starting and ending points of the bar. 3. Designate the starting and ending points of a diagonal line across the bar graph. It makes no difference whether the display position of a bar graph is designated from the right or left, or from the top or bottom. The ending point designates only the length (along the X axis) of the bar graph. Whether the bar is vertical or horizontal is designated later in the display settings. When the length is designated, a display to set direct or indirect referencing will appear. 4. Specify “Direct.” Indirect referencing is not currently supported. The nu- meral table will be displayed.
No. Numeral table entry number
IN (initialize at startup) Indicates whether or not the table value is to be initialized when the PT is turned ON.
# (quantity) Number of PC words used
Word Address of the first PC word
Comment User comment area
Heading Meaning · Contents Initial value

Refer to page 61 for details.
Initialize (Init) Set YES to initialize the contents in the numeral table when PT power is turned ON. Set to NO to maintain the previous value when PT power is turned ON.
Set words (St Word) Set the number of PC words to be used.
Word Set the address of the first PC word to be used.
Comment Input any desired user comment area
The bar graph display settings will appear when the above display is left.

Heading Meaning

Direction Whether the bar is to be displayed in the normal direction or the reverse direction. (See note 1.)
Width The width of the bar graph. The width must be 3 dots or greater to set a frame. The width must be 8 dots or greater when displaying horizontal bars from the top of the screen or when displaying vertical bars from the right of the screen.
Graph Frame Whether or not a graph frame showing 100% is to be displayed.
Disp sign Whether or not a negative (–) sign is to be displayed. If a negative sign is used, the bar graph can be displayed in the reverse direction for negative values. (See note 2.)
100% value The value of the denominator for percentage calculations. You cannot set numerals of 0 or less as the 100% value.
Display % Whether or not the result of percentage calculations is to be displayed as numerals.
Size of % Set the character size of numerals for when percentages are displayed.
Scale Set the scale factor for the percentage display. The NT600M can be set to 64X in addition to those shown above.
bar graphs can be displayed top to bottom or bottom to top. 2. If a display sign (negative value) is specified, the center of the bar will be set as 0% and the right or top of the bar will be set as 100% (for normal displays). (The center will be one dot up or to the left of center for odd- sized bars.) Examples are shown below.
(Number of display dots) = (Maximum length of graph) x
If the results for a bar graph display is over 100%, a 1-dot blank will be displayed past the size set with the Support Tool and an 8-dot bar will be display beyond the blank to indicate a value over 100% (see below).
1 dot 8 dots
Press the Enter Key after completing all of these settings.
When the display position has been set, you can return to set another bar graph or you can continue pressing the Escape Key to return to the Initial Edit Display.

Deleting and Modifying Direct connection bar graphs are deleted or modified from the display shown in step 1. above. Select the number of the numeral table and then specify DELETE or MODIFY. The modification procedure is basically the same as the creation procedure given above.
Memory tables can be displayed for editing or to create lists of screen num- bers referencing a specified table entry. This function is the same when NEXT, F2 (TBL EDIT) is executed from the Screen Selection Display.
The procedure for editing memory tables depends on whether or not direct connection is ON or OFF in the Tool Settings. Both procedures are given be- low.
If you select TBL EDIT on the Initial Edit Display, the Initial Table Editing Dis- play will appear.
Initial Table Edit Display

Selecting the Memory Table Select either numeral table or string table for editing.
Editing the numeral table and string table is explained separately below.
Editing Numeral Tables If you select the numeral table to edit, the following display will appear. For the NT20M, numeral table entries are numbered from 0 to 127, for a total of 128. For the NT600M, numeral table entries are numbered from 0 to 255, for a total of 256. At first, only the contents of table entries 0 to 63 are displayed

on the screen. To display entries 64 and up, press the Pg Dn Key; and to re- turn to previously displayed entries, press the Pg Up Key.

table entry indicated by the cursor will appear. 1, 2, 3... 1. With the cursor, select the numeral table entry that you want to edit, and press the Enter Key. 2. Input the new value and press the Enter Key. 3. When you are finished editing, press the Escape Key. When the Escape Key is pressed, you will be returned to the Memory Table Selection Display.
Editing String Tables If you select character strings to edit, the following display will appear. For the NT20M, string table entries are numbered from 0 to 31, for a total of 32. For the NT600M, string table entries are numbered from 0 to 255, for a total of 256. Only 32 entries are displayed on each page. Use the Pg Up and Pd Dn Keys to scroll to other pages.

table entry indicated by the cursor will appear.

1, 2, 3... 1. With the cursor, select the string table entry that you want to edit, and press the Enter Key. 2. Input the character string and press the Enter Key. 3. When you are finished editing, press the Escape Key.
List of Referencing Screens You can display a list of screens referencing designated number or string table entries by pressing F1 when the numeral or string table is displayed.
With the cursor, select the memory table entry that you want to list references for, and press F1 (Reference). The table below is an example of a memory table reference display. The displayed numbers indicate the screens that ref- erence the designated table entry.

If you select TBL EDIT on the Initial Edit Display, the Initial Table Editing Dis- play will appear.
Selecting the Memory Table Select either numeral table or string table for editing.
Editing the numeral table and string table is explained separately below.
Editing Numeral Tables If the numeral table is specified, the numeral table will appear in the same form as used for numeral editing or bar graphs.
1, 2, 3... 1. Specify the numeral table entry that you want to edit. 2. Input the initial value as desired and continue making or changing set- tings in the same fashion as originally done when creating numeral edit- ing areas or bar graphs. 3. You can continue inputting or changing setting for other numeral table entires when finished with the first one. 4. When you are finished editing, press the Escape Key. When the Escape Key is pressed, you will be returned to the Memory Table Selection Display.
Editing String Tables If the string table is specified, the string table will appear in the same form as used for character string display.
1, 2, 3... 1. Specify the string table entry that you want to edit. 2. Input the initial value as desired and continue making or changing set- tings in the same fashion as originally done when creating string dis- plays.

Words and Numeric Data When setting word addresses for numeral or string tables, the number of PC words to be used and the address of the first word are input. For example, for numeral table entires, one word can be specified to use from 1 to 4 digits and two words can be specified to used from 5 to 8 digits. If two words are speci- fied and DM 0100 is specified as the first word, the following PC data will be used.
0 0 1 2 3 4 5 6
Specified word Next higher word
Set the leftmost digit to F to specify negative values. The example on the left in the following diagram shows the setting for –12345; the example on the right, for –123.
DM 0100
F 0 0 1 2 3 4 5
F 1 2 3
Specified word Next higher word
storage format for PC memory when direct connection is being used. This format, however, differs form that used when direct connection is not being used.
Screens can be create that allow numeric inputs from the PT to the host. These screens are called numeral editing screens. Input values are desig- nated on-screen via function keys or touch switches or from Expansion I/O Units (32/64 Terminals or 12-key Function Key Units). The number of digits that can be input and the number of digits transmitted to the host can be set. Also, the Keypad setting in the screen attributes can be set to “user” to en- able flexible layout of input keys
A maximum of 50 numeral edit settings can be made per screen.
The procedure for creating numeral editing areas depends on whether or not direct connection is ON or OFF in the Tool Settings. Both procedures are giv- en below.
screens. 2. Numeral editing cannot be used if bit input is enabled in the display attrib- utes for PT with function keys or without touch switches.

If you select NUM EDIT from the Initial Edit Display, the following display will appear.
Initial Numeral Editing Display

The headings have the following meanings:
No.: The order that has been set for numeral editing. M Tbl: The number of the numeral table entry which is used. Snd: Number of transmission digits. Inp: Number of input digits. Dsp: Numeral display (Yes/No)
The blank right-hand column is used when reordering number editing areas.
Select the numeral table entry that will be input on-screen.
Inputting Initial Value Input the initial value (contents) for the selected numeral table entry.

Numeral Table Entry

When the initial value is designated, the number of digits input and the num- ber of digits transmitted to the host are set.
Input and Transmission Digits

Input digits (Input Col)
Set the number of digits that can be input via touch switches or function keys. You can set from 1 to 8 digits.
Set the number of digits that are transmitted to the host. You can select either 4 or 8 digits.
Numeral Display (Num Disp)
Select whether or not numeral display is to be set at the same time as numeral editing.
Press the Enter Key after making all the settings.
If Numeral Display is set to “Yes,” the Numeral Display Settings Display will be displayed automatically. Set the numeral display as required.

If Numeral Display is set to “No,” you will be returned to the selection of the memory table for writing.
Transmission Digits (Sending)

Deleting Numeral Editing You can delete numeral edit settings that have already been made.
1, 2, 3... 1. To delete a numeral editing setting, move the bar cursor to the setting you want to delete on the Initial Display for Numeral Editing and then press the Enter Key.

those settings will be shown in a guide box. 2. The switch display at the bottom of the screen will disappear if all numeral editing settings are deleted.
You can modify a numeral edit settings that has already been made.
1, 2, 3... 1. Move the bar cursor to the numeral edit setting you want to modify, and press the Enter Key. The contents of the numeral editing setting that you select will be displayed on the screen.
settings will be shown in a guide box.
Modifying Numeral Editing

Changing the Order of Numeral Editing
You can change the order of numeral edit settings that have already been made.
1, 2, 3... 1. Press F2 (Change Order). A list of numeral edit settings will be dis- played on the screen.

settings will be shown in a guide box.
Input Key Layout Numeral input keys can be placed as desired on the PT screen if the Keypad setting in the screen attributes is set to “user.” The layout operation is per- formed starting from the Screen Selection Display.
ridden by those of the parent screen, i.e., parent screen attributes take prior- ity.
Use the following procedure to create and layout keys for numeral input.
1, 2, 3... 1. Set the “Keypad” screen attribute to “User.” Refer to page 78 for the set- ting procedure. The default attribute is “System,” and will have to be changed. If this attribute is set to “System” the input keys for numeral editing will appear in their normal fixed positions when the F4 Key is pressed in the next step. 2. Create and place the input keys as desired using either the touch switch function described on page 46 or press the F4 Key from the Numeral Editing Display and use the edit function described on page 87.
Key allocations depend on the model of PT being used. Included are the al- locations for function keys.

Touch Panel PTs (DT___)

through F cannot be used for the keypad even if they are set.
Function Key PTs (DF___)

F1 (1) 0 F5 (5) 4 F9 (9) 8
F2 (2) 1 F6 (6) 5 F10 (0) 9
F3 (3) 2 F7 (7) 6 F11 (CLR) 10
F4 (4) 3 F8 (8) 7 F12 (+/–) 11
PTs without Touch Panels (DN___)

F1 (1) 0 F10 (5) 9 F23 (.) 22
F2 (2) 1 F11 (5) 10 F24 (HOME) 23
F3 (3) 2 F12 (6) 11 F25 () 24
F4 (4) 3 F17 (7) 16 F26 () 25
F5 (5) 4 F18 (7) 17 F27 () 26
F6 (6) 5 F19 (8) 18 F28 () 27
F7 (7) 6 F20 (6) 19 F29 (ENTER) 28
12-key Function Key Units

F1 (1) 0 F5 (5) 4 F9 (9) 8
F2 (2) 1 F6 (6) 5 F10 (0) 9
F3 (3) 2 F7 (7) 6 F11 (CLR) 10
F4 (4) 3 F8 (8) 7 F12 (+/–) 11
32/16 Terminals

Numeral editing is not possible for PTs without Touch Panels is Expansion I/O Units with 10/02 Terminals are used.
Creating Use the following procedure to create a direct connection numeral editing area.
1, 2, 3... 1. Select NUM EDIT from the Initial Edit Display, a list of the numeral edit- ing already existing in the current screen will be displayed.


No. Numeral table entry number
IN (initialize at startup) Indicates whether or not the table value is to be initialized when the PT is turned ON.
# (quantity) Number of PC words used
Word Address of the first PC word
Comment User comment area
Refer to page 61 for details.
Initialize (Init) Set YES to initialize the contents in the numeral table when PT power is turned ON. Set to NO to maintain the previous value when PT power is turned ON.
Set words (St Word) Set the number of PC words to be used.
Word Set the address of the first PC word to be used.
Comment Input any desired user comment area
Heading Meaning · Contents Initial value · Heading Meaning

The numeral editing settings will appear when the above display is left.

Number of integer digits (Integer)
Set the number of digits for the integer portion of the number.
Number of decimal digits (Decimal)
Set the number of digits for the decimal portion of the number.
Zero suppress (Zero Sup)
Set whether or not leading zeros are to be displayed on the screen.
Display sign (Disp Sign)
Set whether or not negative signs are to be displayed on the screen. The positive sign is not displayed.
Character size (Char Size)
Set the size of characters to be displayed on the screen.
Scale Set the scale factor for the display. The NT600M can be set to 64X in addition to those shown above.
Attributes Sets display attributes for the screen. Refer to page 24 for examples of how attributes are displayed on screen.
Press the Enter Key after completing all of these settings. 7. Set the display position. When the display position has been set, you can return to set another numeral editing area or you can continue pressing the Escape Key to return to the Initial Edit Display.
Deleting and Modifying Direct connection numeral editing is deleted or modified from the display shown in step 1. above. Select the number of the numeral table and then specify DELETE or MODIFY. The modification procedure is basically the same as the creation procedure given above.
Input Key Layout If the Keypad setting in the screen attributes is set to “user,” input keys can be created and positioned the same as they can for normal numeral editing. Refer to page 66 for details.
The following limitation exist when creating numeral editing screens depend- ing on the model of the PT.

PT Bit input disabled Bit input enabled
DF___ or DN___ with 12-key Function Key Unit
F1 through F12 can be used. Numeral editing is not possible.
DN___ with 32/16 Terminal F1 through F12 and F17 through F29 can be used. F13 through F16 are used as system keys.
Numeral editing is not possible. F13 through F16 are used as system keys.
DT___ Touch switches 231 through 255 can be used for numeral editing input keys.
Touch switches 231 through 255 can be used for numeral editing input keys or for normal touch switches.
Polylines (a broken line made up of one or more line segments) can be created on the screen. You can make a polyline by connecting a maximum of 255 line segments. The amount of polyline data for a screen depends only on the amount of memory remaining. Select GRAPHIC from the Initial Edit Dis- play to access the Graphic Input Display and then select POLYLINE. The Initial Polyline Display will appear.

1, 2, 3... 1. Specify CREATE. 2. Designate the starting point of the polyline by positioning the cursor and pressing the Enter Key. 3. Designate the mid-points (the points between the starting point and the ending point) for the polyline in the same fashion. To return to the previously designated point, press the Escape Key. To stop the process and return to the Initial Edit Display, press the Es- cape Key.
Initial Polyline Display

You can delete polylines set on the screen.
1, 2, 3... 1. Specify DELETE. The starting points for all of the polylines on the screen will be indicated by small squares.
You can modify polylines set on the screen.
1, 2, 3... 1. Select MODIFY. The starting points for all of the polylines on the screen will be indicated by small squares.

Circles can be created on the screen. The amount of circle data for a screen depends only on the amount of memory remaining. Select GRAPHIC from the Initial Edit Display to access the Graphic Input Display and then select CIRCLE. The Initial Circle Display will appear.

1, 2, 3... 1. Specify CREATE. 2. Designate the center of the circle. The center of the circle will be indi- cated by an x.
Initial Circle Display

2-10-2 Deleting Circles
You can delete circles set on the screen.
1, 2, 3... 1. Specify DELETE. The center points for all of the circles on the screen will be indicated by small squares.
1, 2, 3... 1. Specify MODIFY. The center points for all of the circles on the screen are indicated by small squares.

You can combine previously created multiple screens into a continuous screens by linking them or into one screen by stacking them into overlapping screens. To make continuous screens, first one screen is designated as the parent screen, and then child screens and the screen scrolling unit are set for the parent screen. To make overlapping screens, first one screen is desig- nated as the parent screen, and then child screens are designated for the parent screen.
Setting the Parent Screen On the Screen Selection Display, move the bar cursor to a screen number for which no data is entered, and press F8 (continuous/overlapping screens).

If you designate a screen for which data is already registered, a message will appear asking whether you want to delete that data. If you do want to delete it, then press the Enter Key.
To return to the Screen Selection Display, press the Escape Key.
If the designated screen is already a parent screen, its contents (the child screens) can be edited.
Selecting Continuous or Overlapping
Specify whether the designated parent screen is to be used for continuous or overlapping screens.
Continuous and overlapping screens are explained separately below.
screen data could not be created. If that happens, press any key and then again select the child screens again.

Continuous Screens The screen numbers of the child screens you want to display continuously are registered next. Register the child screen numbers in the order that you want them displayed. You can register a maximum of 8 child screens.

1, 2, 3... 1. Select all the screen numbers of the child screens you want with the cursor and Space Bar. The screen numbers that you select will be marked with asterisks. 2. When all of the child screens you want have been marked, press the Enter Key. 3. Select scrolling by screen or by line, and then press the Enter Key to select a screen. Asterisks will appear by selected as child screens. For line scrolling, scrolling is done in increments of 8 dots. The NT600M does not have the line scrolling function, so the screen shown below will not be displayed. Also, line scrolling cannot be used with the direct con- nection function.



Overlapping Screens Register the screen numbers of the child screens you want to display over- lapped. There is no particular order of registration. You can register a maxi- mum of 8 child screens.

1, 2, 3... 1. Select all the screen numbers of the child screens you want with the cursor and Space Bar. Selected screens will be indicated with asterisks. 2. After all of the child screens have been designated, press the Enter Key. 3. Input the screen comment, and press the Enter Key or press the Escape Key to return to step 2. Comments can be up to 24 characters.

displays, lamps, touch switches, or bar graphs, be sure that these various display elements do not overlap. 2. Only screen attributes set for the parent screen will be used. Parent screen attributes will not change unless they are changed directly (i.e., changing child screen attributes will not affect parent screen attributes).
You can set attributes for one screen at a time, or for multiple screens togeth- er. The following attributes can be set: buzzer, history record, bit input, and alarm output.
1, 2, 3... 1. Go to the Screen Selection Display. 2. If you are setting only one screen move the bar cursor to the number of the screen you want to set, and press F4 (Attributes). If you are setting multiple screens at one time, tag the desired screens with the Space Key and then press F4 (Attributes).
tion time will be lengthened. In such cases, returning to the File Selection Display and then enter the Screen Selection Display before performing the operation.

Screen attributes are described in the following table. Set each attribute and then press the Enter Key. The history title is input next.
Screen Designation · Setting Attributes

Buzzer Whether or not the buzzer is to sound when the screen is displayed. If the buzzer is set to sound, you can select either continuous or intermittent operation.
History Whether or not the history of the screen is to be recorded. If you set “Yes,” then, when the Programmable Terminal (PT) is operating, all screens have been displayed will be recorded in the PT. You can check the contents of these records by selecting History Records from the Maintenance Menu of the PT. You can also transmit the contents to the Support Tool.
Bit Input (Bit In)
Whether or not the host is to be notified, in the form of a bit input, of the push-down status of touch switches or function keys while the screen is displayed. This setting is not used for RS-232C and RS-422 communications. To enable notification, set either touch switches or function keys to specify the input device of the PT to be used.
Alarm Whether or not the PT alarm output will turn ON when the screen is displayed.
Keypad Set “System” to use the default key layout or “User” to specify a custom key layout.
Backlight Color (Back Col)
Specify white or red as the backlight color if the NT20M-DT131/DN131 is to be used.
Specify “Light” or “Flash” for the screen backlight if the NT20M-DT131/DN131 is to be used.
History Title If the screen history is enabled, the following display will appear requesting a title for the history. If screen attributes are being simultaneously input for more than one screen, the same title will be used for all of the screens. The following display is for multiple screens.

Input the history title, and press the Enter Key to return to the Screen Selec- tion Display. The title can be up to 24 characters.
Attributes Function · Backlight operation (Backlight)

Screen Attribute Displays After the settings have been made, their contents will be displayed in the sta- tus column on the screen listing as letters of the alphabet.

G Extended functions (Backlight color or backlight operation): Displayed for the NT20M-DT131/DN131
When continuous or overlapping screens are received from the PT as a single screen, there is a chance that screen errors may occur in these files. Check to see whether such errors have occurred. You can print out the con- tents of this check.
Screen Errors If a screen that has been designated as a child screen for continuous or overlapping screens is subsequently designated as a parent screen for

another continuous or overlapping screen, it results in a screen error. A check can be performed as shown below from the Screen Selection Display

1, 2, 3... 1. Press NEXT, F3 (Check). A message will appear asking whether or not you want the results of the screen check to be printed out. 2. Select “Yes” or “No” and then press the Enter Key. Regardless of wheth- er you select Yes or No, the results will be displayed on the screen. The contents will be displayed as shown below. The results of the check are printed out in the same form.

No. Shows the numbers of all screens designated as parent screens for continuous or overlapping screens.
Error Indicates whether or not there is an error for the child settings.
Contents Shows the numbers of all screens designated as child screens. If any of these child screens has an error, its number will be underlined.
Item Contents

played. 2. The paper size for printing is A4 (portrait). Other settings can result in printing errors.
Marks can be created for display on the PT. If you press F9 on the Screen Selection Display or specify MARK from the Initial Edit Display, the Mark Cre- ation Display will appear. This display is split in half, with a creation display on the right and a reference display on the left. The reference display can be used to display previously created marks for copying all or part of them to the creation display.

Keys Usable on Mark Creation Display
The dots used to create marks can be manipulated using the mouse and/or the keyboard.
The left mouse button can be clicked to turn ON specific dots or the right mouse button can be clicked to turn OFF specific dots. Either button can be held down to continuously manipulate dots by moving the mouse.
The Up, Down, Left, and Right Keys are used to position the cursor, and the Shift Key is used to set or clear dots one at a time. A continuous series of dots can be cleared or set by using the Shift Key together with the direction keys. The direction keys can also be combined with the Alt Key to move the Creation Display.
to prevent problems with the Caps Key locking.
The Alt Key is used simultaneously with any of the direction keys to move the Creation Display in the designated direction. In addition, you can rotate the Creation Display 90% by simultaneously pressing the Alt Key, the Shift Key, and the Left Key for counterclockwise rotation or Right Key for clockwise ro- tation.
The Escape Key is used to end mark creation and return to the Screen Se- lection Display. When the Support Tool asks for confirmation, press the Re- turn Key to end mark creation or the Escape Key to continue. Be sure to saved required mark data before ending mark creation.
Mark Creation Display

The function keys are used as described in the following table.
F1 Mark Reference (Mk Ref)
Displays designated marks on the reference display.
F2 Copy (Copy) Copies a designated rectangular area on the creation display to another position.
F3 Reference Copy (RCopy)
Copies a designated rectangular area on the reference display to a designated position on the creation display.
F4 Area Set (Set) Sets all of the dots for a designated rectangular area on the Creation Display.
F5 Area Clear (Clr)
Clears all of the dots for a designated rectangular area on the creation display.
F6 Inverse (Inv) Reverses the status of all of the dots on the creation display.
F7 Save (Save) Registers, as a mark, data which is displayed on the creation display.
Setting and Clearing Dots To set or clear dots, move the cursor with the direction keys, and then press the Shift Key. Pressing the Shift Key will clear dots at the cursor position which are set, and set dots at the cursor position which are cleared. By oper- ating the direction keys while continuing to hold down the Shift Key, you can set or clear a continuous series of dots. The results of setting or clearing dots are always displayed inside of brackets at the top of the creation display.
Dots can also be set and clear using the mouse. Use the left mouse button to set dots and the right mouse button to clear them. Dots will be continuously set or cleared if the mouse button is held down while moving the mouse.
Mark Reference F1 is used to display designated marks on the Reference Display. You can copy the contents of the reference display to the creation display with F3 (Reference Copy). (See page 84.)
1, 2, 3... 1. Press F1 (Mark Reference), to display the Mark List Display.

Function Keys · Key Key Function

Copy F2 is used to copy a designated rectangular area on the creation display to another position. This operation can be canceled at any point by pressing the Escape Key.
starting point, ending point, etc. If you are not sure of the position of the cur- sor, move it with direction keys. 1, 2, 3... 1. If you press F2 (Copy), the following screen will be displayed.


Reference Copy F3 is used to copy a designated rectangular area on the reference display to a designated position on the creation display.

Operation is basically the same as for copying with F1 except that the copy is designated on the reference display and created on the creation display.
Area Set F4 is used to fill in a designated area on the creation display.
Area designation is basically the same as for copying with F1.
Area Clear F5 is used to clear all of the dots for a designated rectangular area on the creation display. After being cleared, they are represented by small dots.
Area designation is basically the same as for copying with F1.
Inverse F6 is used to reverse all of the dots on the creation display.
Area designation is basically the same as for copying with F1.
Save F7 is used to register data in the creation display as a mark.
1, 2, 3... 1. Enter F7 (Save), the mark list will be displayed. 2. Specify the position in which to save the mark. If you specify a position that already contains a mark, the existing mark will be overwritten by the new one. 3. Press the Enter Key. Saving can be canceled by pressing the Escape Key.
You can confirm that the mark has been saved by pressing F1.
Ending Mark Creation Press the Escape Key when finished creating mark to end mark creation and return to the Screen Selection display. A confirmation display will appear. Press the Enter Key to confirm or press the Escape Key to continue mark creation.
creation is canceled at the confirmation display, however, any unsaved data will be maintained.
Stand-alone operation allows the PT touch switches, function keys, and Ex- pansion I/O Units to be used to switch screens without receiving instructions from a host. The Support Tool must be used to set up stand-alone operation.
Precautions When screens are changed during stand-alone operation, a screen number request response is sent from the PT to the host.
If the same key number is allocated in multiple child screens, the key will be effective only in the child screen with the smallest screen number.
The following screen numbers can be set.
The following touch switches and function keys can be allocated.
Touch switches: 000 to 031 Function keys DF___: F1 to F12 Other: 01 to 31
Numeral editing will take priority if both numeral editing and stand-alone op- eration are specified for the same screen. Although both numeral editing and stand-alone operation use function keys and touch switch, the following li- mitation apply to stand-alone operation if numeral editing is also being used.

PT with Touch Panels (DT___) Touch switches 231 to 255 cannot be used.
PT with Function Keys (DF___) Stand-alone operation is not supported.
PT without Function Keys (DN___) 12-key Function Key Units Stand-alone operation is not supported.
32/16 Terminals F1 to F12 and F17 to F29
10/02 Terminals Numeral editing not supported. F1 to F10 can be used for stand-alone operation.
Operation Select EXTEND from the Initial Edit Display to access the Extended Features Display shown below. This display will appear only if direct connection is set to No in the Tool Settings.

Use the following procedure to allocate screens to switches/function keys.
1, 2, 3... 1. Press the Enter Key to access the Stand-alone Setting Display.

PT Limitations · Extended Features Display

Restrictions The following touch switches/function keys can be used depending on the model of the PT. Refer to the Precautions section, above, for restrictions when using numeral editing with stand-alone operation.
PT Applicable touch switches/function keys
PT with Touch Panels (DT___) 0 to 255
PT with Function Keys (DF___) F1 through F12
PT without Function Keys (DN___) 12-key Function Key Units Stand-alone operation is not supported.
32/16 Terminals F1 to F32
10/02 Terminals F1 to F10
The cut and paste operations under EDIT on the Initial Edit Display can be used to copy, move, or delete previously created elements such as character strings and graphics. The Edit Display will appear.

Key followed by the Space Bar from the Edit Display.
Copy Use the following procedure to copy existing elements on the screen.
1, 2, 3... 1. Specify COPY from the Cut and Paste Display 2. Move the cursor to designate the starting point of the copy area and press the Enter Key. 3. Move the cursor to designate the end point of the copy area and press the Enter Key. The specified copy area will be indicated by a dotted box.
Edit Display

4. Move the cursor to designate the area in which to paste the copy and press the Enter Key. The area to which the copy will be made will be designated by a dotted box when the cursor is moved. 5. Press the Enter Key again when the confirmation message appears to paste the copy or press the Escape Key to cancel the paste and return to step 6. Return to step 2. to make further copies or press the Escape Key to end the copy operation.
Move Use the following procedure to move existing elements on the screen.
1, 2, 3... 1. Specify MOVE from the Cut and Paste Display 2. Move the cursor to designate the starting point of the move area and press the Enter Key. 3. Move the cursor to designate the end point of the move area and press the Enter Key. The specified move area will be indicated by a dotted box. 4. Move the cursor to designate the area to move to and press the Enter Key. The area to which the move will be made will be designated by a dotted box when the cursor is moved. 5. Press the Enter Key again when the confirmation message appears to execute the move or press the Escape Key to cancel the move and re- turn to step 4. 6. Return to step 2. to move other elements or press the Escape Key to end the move operation.
Delete Use the following procedure to delete existing elements on the screen.
1, 2, 3... 1. Specify DELETE from the Cut and Paste Display 2. Move the cursor to designate the starting point of the delete area and press the Enter Key. 3. Move the cursor to designate the end point of the delete area and press the Enter Key. The specified delete area will be indicated by a dotted box. 4. Press the Enter Key again when the confirmation message appears to execute the move or press the Escape Key to cancel the move and re- turn to step 1. 5. Return to step 2. to delete other elements or press the Escape Key to end the delete operation.

This section describes how to copy and delete previously created screens, to change screen comments, and to read screen in from other files.
3-1 Copying Screens 90 3-2 Deleting Screens 91 3-3 Changing Screen Comments 92 3-4 Reading Data from Other Files 93

3-1 Copying Screens
You can copy designated screens to different screens. To copy a screen, first designate the source screen number and then designate the target screen number as described below.
1, 2, 3... 1. Go to the Screen Selection Display.

message will appear indicating that data already exists and asking you if you wish to overwrite it. If it is overwritten, any data stored up to that point will be cleared. If you choose to overwrite the existing data, press the Enter Key. If

you wish to cancel, return to the Screen Selection Display by pressing a key other than the Enter Key.
You can delete one or more screens that has previously been set. Screen data can also be deleted from the PT.
1, 2, 3... 1. Go to the Screen Selection Display.



You can change designated screen comments.
1, 2, 3... 1. Go to the Screen Selection Display.


Screens contained in other files can be read into the current file from the Screen Selection Display. Although entire files can be copied from the File Selection Display, copying from the Screen Selection display enables copy- ing one screen at a time into the current file. The files being copied from can be either in the current data directory set in the Tool Settings or in a different drive/directory.
Use the following procedure to read a screen from any accessible file.
1, 2, 3... 1. Change to the Screen Selection Display.

Screen Selection Display



6. To read data from the displayed data directory, continue to step 8. To change the directory, press F1. 7. Specify the drive and directory of the file to be read from. A list of files in the specified directory will be displayed. 8. Specify the file from which a screen is to be read. A list of the screens in the specified file will appear. 9. Specify the screen to read. A confirmation message will appear. 10. Confirm the read or cancel the operation by pressing any key but the Enter Key. If the read is confirmed, the screen data will be inserted into the specified screen or the screen that is read will overwrite the speci- fied screen, as specified in step 4.

This section describes how to manage file data, including copying and deleting files, as well as settings such as PT histo- ries and initial screens that are set for the entire file.
4-1 Copying Files 96 4-2 Deleting Files 97 4-3 Changing File Titles 98 4-4 Saving PT Histories in Files 98 4-5 Setting Initial Screens 99
memory capacities, this feature is no longer required. Memory capacities are now automatically changed when files are updated and all files are displayed on file lists regardless of capacity.

4-1 Copying Files
You can copy all the contents of a designated file (i.e., screen data, memory table data, and mark data) to another file. The file can be in any accessible directory.
1, 2, 3... 1. Go to the File Selection Display.


3. To copy a file from the displayed list, go to step 5. To copy a file in a dif- ferent directory, press F1. An input field for the drive and directory names will appear. 4. Specify the drive and directory from which a file is to be copied. A list of files in the specified directory will be displayed. 5. Specify the file to be copied or press the Escape Key to cancel. 6. Input a name of up to 8 normal characters for the file to which the data is to be copied, and then press the Enter Key. 7. Input a title of up to 28 characters, and then press the Enter Key or press the Escape Key to cancel.

pear indicating that the file name already exists, and asking you if you wish to overwrite the existing file. If it is overwritten, any data stored up to that point will be cleared. If you wish to overwrite the existing file, press the Enter Key. If you wish to cancel, return to step 6. by pressing a key other than the Enter Key. Then input another name for the new file.
You can delete all the contents of a designated file (i.e., screen data, memory table data, and mark data).
1, 2, 3... 1. Go to the File Selection Display.

4-3 Changing File Titles
You can change file titles that are already set.
1, 2, 3... 1. Go to the File Selection Display.
History information recorded in the PT can be received through the tool inter- face and saved in a file. The file that you save is a text file, so you can check its contents with the MS–DOS “TYPE” command. History files can also be printed. Refer to Section 5 Printing for details.
1, 2, 3... 1. Go to the File Selection Display.



indicating that the file name already exists, and asking you if you wish to overwrite the existing file. If it is overwritten, any data stored up to that point will be cleared. If you wish to overwrite the existing file, press the Enter Key. If you wish to cancel, press a key other than the Enter Key and then input another name for the file.
Saving Files A file name extension is attached to the file name that is input, and the file name is stored in the Tool Settings data directory. For example, if the data directory is set as B: \DATA, and LOGFILE is input as the file name, then the data received will be saved to B: \DATA\LOGFILE.LOG.
The history records are stored in the file first by order of occurrence and then by order of frequency.
The Programmable Terminal will display a previously designated initial screen when the PT is turned on or reset.
1, 2, 3... 1. Go to the File Selection Display.


not be effective unless a file is sent to the PT after the setting has been made. To send the file, press F6 (Transmit) from the File Selection Display. If you do not set a initial screen number, the default setting will be 1 unless the screen is initialized at the PT, in which case the default setting will be 0.

Printing
This sections describes the procedures for printing screen images and other information from the Screen Selection and File Selection Displays.
5-1 Printing Features 102 5-2 Printing from the File Selection Display 102 5-3 Printing from the Screen Selection Display 103

5-1 Printing Features
The F3 Function Key can be used from the File Selection Display or the Screen Selection Display to print out actual screens or to print out data re- lated to screens.
File Selection Display The following can be printed from the File Selection Display.
Screen Selection Display The following can be printed from the Screen Selection Display.
screens and other information are printed on one or more page each. 2. Set the printer up before attempting to print. 3. A printing error may occur f the printer’s SEL switch is ON when printing is started. If this happen, press any key, return to the Screen Selection Display and repeat the printing process from the beginning. 4. The paper size for printing is A4 (portrait). Other settings can result in printing errors. 5. Nothing will be printed if no data exists for a specified item. 6. Detailed information will not be printed for polylines and circles. 7. Only 62 lines will be printed per page before pagination. 8. The maximum length printed for character data is 32 characters. 9. Only child screens will be printed for continuous or overlapping screen unless a screen image is specified. If a screen image is specified for con- tinuous screens, only the first child screen and the screen numbers of the child screens will be printed. If a screen image is specified for overlapping screens, the overlapping screen and the screen numbers of the child screens will be printed.
1, 2, 3... 1. Go to the File Selection Display 2. Specify the file from which to print. 3. Specify F3. The following display will appear.



in character strings printed in detailed information.
1, 2, 3... 1. Go the the Screen Selection Display. 2. If you are printing only one screen, move the bar cursor to the number of the screen you want to print, and press F3 (Print). If you are printing multiple screens at one time, tag the screen numbers that you want to print and then press F3 (Print). The following display will appear.



This section describes the procedures to transfer screen and memory table data between the PT and the Support Software. The procedure to delete screens directly from the PT is also provided.
6-1 Connecting to the PT 106 6-2 Transmitting Data 106 6-3 Receiving Data 110 6-4 Deleting PT Screens 114

6-1 Connecting to the PT
Before beginning transfer operations, connect the computer to the Program- mable Terminal according to the system configuration shown below.


5.25” floppy disk
3.5” floppy disk

100 to 240 VAC 50 Hz/ 60 Hz
grammable Terminal operation manual.
Data created with the Support Tool (i.e., screen data, memory table data, and mark data) can be transmitted either by file or by screen (i.e., single screens, multiple screens, or memory tables).
24-VDC power supply

Transmitting Files When you transmit a file, screen data, memory table data, and mark data registered in the PT is completely overwritten unless the resume operation is set to ON. If the resume operation is ON, memory table data will not be changed.
advance from the maintenance menu to transfer data to the PT’s image data memory.
1, 2, 3... 1. Go to the File Selection Display. 2. Move the bar cursor to the file you want to transmit, and then press F6 (Transmit). A message will appear asking whether you actually want to transmit the file. 3. If you do want to transmit it, press the Enter Key. To return to the File Selection Display, press any key other than the En- ter Key.



Transmitting Screens You can transmit single or multiple screens.
so check these screens carefully before sending them. 2. This operation is not possible if EEPROM is used in the PT. Transfer files only. 1, 2, 3... 1. Go the the Screen Selection Display. 2. If you are transmitting only one screen, move the bar cursor to the num- ber of the screen you want to transmit, and press F6 (Transmit). If you are transmitting multiple screens at one time, tag the screen num- bers that you want to transmit and then press F6 (Transmit).



A message will be displayed asking whether you actually want to trans- mit the data. The following example shows a case where the tag func- tion is used to designate multiple screens for transmission.

5. To confirm, press the Enter Key. To return to step 1, press any key other than the Enter Key. 6. When the transmission is complete, a message will be displayed. Press any key to return to the Screen Selection Display. 7. If you choose to have the data confirmed, then after the data has been transmitted the PT will read the data and check it. This makes possible a more reliable transmission, but it takes more time than if the data is not confirmed. Transmitting Memory Tables
the resume operation to OFF before transferring memory tables. 1, 2, 3... 1. Go to the Screen Selection Display. 2. Press F6 (Transmit). The position of the bar cursor is irrelevant.

A message will be displayed asking whether you actually want to trans- mit the data.

Data registered in the PT (i.e., screen data, memory table data, and mark data) can be received either by file or by screen (i.e., single screens or memory tables). Screen comments, however, are not transferred to PT memory and can thus not be received.
Receiving Files All screen data, memory table data, and mark data together can be received in one file.
1, 2, 3... 1. Go to the File Selection Display. 2. Press F7 (Receive). The position of the bar cursor is irrelevant.



indicating that the file name already exists, and asking you if you wish to overwrite the existing file. If it is overwritten, any data stored up to that point will be cleared. If you wish to overwrite the existing file, press the Enter Key. If you wish to cancel, return to step 1 by pressing a key other than the Enter Key and then input another name for the file.
1, 2, 3... 1. Go to the Screen Selection Display. 2. Press F7 (Receive). The position of the bar cursor is irrelevant.
Receiving Screens






sage will appear indicating that data already exists at the designated number and asking you if you wish to overwrite that data. If it is overwrit- ten, any data stored up to that point will be cleared. If you wish to over- write the existing file, press the Enter Key. If you wish to cancel, return to step 1 by pressing a key other than the Enter Key. 2. Before receiving continuous or overlapping screens, check carefully to ensure that the Support Tool has no errors in screen data.
data set via the Support Tool.
Receiving Memory Tables

1, 2, 3... 1. Go to the Screen Selection Display. 2. Press F7 (Receive). The position of the bar cursor is irrelevant.

You can delete designated screens from the PT.
1, 2, 3... 1. Go to the Screen Selection Display. 2. Press F2 (Delete). The position of the bar cursor is irrelevant.






This section describes the procedure for transferring screen file data between a PROM writer and the Support Tool.
7-1 Connecting to a PROM Writer 118 7-2 Transmitting Data to a PROM Writer 118 7-3 Transmitting Data with Verification to a PROM Writer 119 7-4 Receiving Data from a PROM Writer 120

7-1 Connecting to a PROM Writer
Before performing operations, connect an IBM PC/AT and a PROM writer. Use RS-232C interface for data communications with the PROM writer. Set the transmission conditions as shown in the following table.
Baud rate 9,600 bps
Data length 8 bits
Transfer format Intel HEX format
IBM PC/AT PROM writer

be written. 2. Data will not be transferred correctly if the capacity of the RAM buffer in the PROM Writer is less than that of the PT’s ROM.
Data created by the Support Tool can be transmitted to a PROM writer by file.
1, 2, 3... 1. Go to the File Selection Display. 2. Move the bar cursor to the file you want to transmit, and press F4 (ROM).

Parity None · Stop bits 1


In this case, data created by the Support Tool is sent to a PROM writer by file. After transmission is complete, the data is received back from the PROM writer and checked to see whether it was transmitted correctly. 1, 2, 3... 1. Go to the File Selection Display. 2. Move the bar cursor to the file you want to transmit with verification, and then press F4 (ROM).


6. After verifying that that PROM writer can receive the data, press the En- ter Key. To cancel and return to step 3, press the Escape Key. 7. When the transmission is complete, the following message will be dis- played and the Support Tool will wait for the data to be sent back from the PROM writer. Transmit the data from the PROM writer. 8. If all of the data received matches the data that was transmitted, a mes- sage will be displayed. To return to step 1, press any key.
Data can be received from the PROM writer by file.
1, 2, 3... 1. Go to the File Selection Display. 2. Press F4 (ROM). The position of the bar cursor is irrelevant.



be able to save a work file used for receiving the data and a storage file for saving the data received. Be sure, therefore, to reserve at least 256 K for the NT20M and 512 K for the NT600M. 2. If the memory capacity setting for the file in which the data received is stored differs from memory capacity setting in Tool Settings, then the file will not be displayed even if you return to the File Selection Display. If that happens, change the setting in Tool Settings. 3. If you designate a new file with the same name as an existing file, a mes- sage will appear indicating that the file name already exists, and asking you if you wish to overwrite the existing file. If it is overwritten, any data

stored up to that point will be cleared.If you wish to overwrite the existing file, press the Enter Key. If you wish to cancel, return to step 1 by pressing a key other than the Enter Key. Then input another name for the new file.

English Character Codes
Pin 3 of SW1 must be ON to enable English language messages to use the following codes.
Example: Hex code is represented by 30, decimal code by 48, and character by 0.
Code 20 and 32 in the table represents a space, as indicated by “SP”.
Hex Digits 1st 2nd
-0 20 SP 30 0 40 @ 50 P 60 ‘ 70 p 80 Ç 90 É
32 48 64 80 96 112 128 144
-1 21 ! 31 1 41 A 51 Q 61 a 71 q 81 ü 91 æ
33 49 65 81 97 113 129 145
-2 22 ” 32 2 42 B 52 R 62 b 72 r 82 é 92 Æ
34 50 66 82 98 114 130 146
-3 23 # 33 3 43 C 53 S 63 c 73 s 83 â 93 ô
35 51 67 83 99 115 131 147
-4 24 $ 34 4 44 D 54 T 64 d 74 t 84 ä 94 ö
36 52 68 84 100 116 132 148
-5 25 % 35 5 45 E 55 U 65 e 75 u 85 à 95 ò
37 53 69 85 101 117 133 149
-6 26 & 36 6 46 F 56 V 66 f 76 v 86 å 96 û
38 54 70 86 102 118 134 150
-7 27 ’ 37 7 47 G 57 W 67 g 77 w 87 ç 97 ù
39 55 71 87 103 119 135 151
-8 28 ( 38 8 48 H 58 X 68 h 78 x 88 ê 98 ÿ
40 56 72 88 104 120 136 152
-9 29 ) 39 9 49 I 59 Y 69 i 79 y 89 ë 99 Ö
41 57 73 89 105 121 137 153
42 58 74 90 106 122 138 154
-B 2B + 3B ; 4B K 5B [ 6B k 7B { 8B ï 9B ¢
43 59 75 91 107 123 139 155
-C 2C , 3C < 4C L 5C \ 6C l 7C | 8C î 9C £
44 60 76 92 108 124 140 156
-D 2D - 3D = 4D M 5D ] 6D m 7D } 8D ì 9D ¥
45 61 77 93 109 125 141 157
-E 2E . 3E > 4E N 5E ^ 6E n 7E ~ 8E Ä 9E Pt
46 62 78 94 110 126 142 158
-F 2F / 3F ? 4F O 5F _ 6F o 7F 8F Å 9F ƒ
47 63 79 95 111 127 143 159


-0 A0 á B0 C0 D0 E0 α F0 ≡
-1 A1 í B1 C1 D1 E1 β F1 +
-2 A2 ó B2 C2 D2 E2 Γ F2 ≥
-3 A3 ú B3 C3 D3 E3 π F3 ≤
-4 A4 ñ B4 C4 D4 E4 Σ F4 ⌠
-5 A5 Ñ B5 C5 D5 E5 σ F5 ⌡
-6 A6 a B6 C6 D6 E6 m F6 ÷
-7 A7 o B7 C7 D7 E7 τ F7 ≈
-8 A8 ¿ B8 C8 D8 E8 Φ F8 %
-9 A9 B9 C9 D9 E9 Θ F9 .
-A AA BA CA DA EA W FA •
-B AB 1/2 BB CB DB EB δ FB √
-C AC 1/4 BC CC DC EC ∞ FC n
-D AD ¡ BD CD DD ED f FD 2
-E AE « BE CE DE EE ε FE
-F AF » BF CF DF EF ∩ FF

A manual revision code appears as a suffix to the catalog number on the front cover of the manual.
Cat. No. V004-E1-2
The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version.
Revision code Date Revised content
1 September 1991 Original production
2 August 1993 Major revisions for new version of software.
Revision code