EN
Omron logo
Official user manual

Omron Programmable Terminal (NT20M)

131 pages·1.3 MB·Satellite TV System·PDF·ENDEFRITNLJA
Omron Programmable Terminal (NT20M)
Table of Contents 13 sections Front Page · Table of Contents · About this Manual · Introduction · … ShowHide
Page 1 of the Omron Programmable Terminal (NT20M) user manual — NT-series NT20M/NT600M Support Tool
Page 1 · click to enlarge
Page 1

NT-series NT20M/NT600M Support Tool

Operation Manual

Omron Programmable Terminal (NT20M) — NT-series NT20M/NT600M Support Tool diagram (page 1)
Fig. 1 · NT-series NT20M/NT600M Support Tool
Omron Programmable Terminal (NT20M) — NT-series NT20M/NT600M Support Tool diagram (page 1)
Fig. 2 · NT-series NT20M/NT600M Support Tool

Revised August 1993

Page 2 of the Omron Programmable Terminal (NT20M) user manual — OMRON, 1991
Page 2 · click to enlarge
Page 2

Notice:

OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual.

The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to head precautions can result in injury to people or dam- age to the product.

OMRON Product References

All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product.

The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “word” and is abbreviated “Wd” in documentation in this sense.

The abbreviation “PC” means Programmable Controller and is not used as an abbreviation for any- thing else. Visual Aids

The following headings appear in the left column of the manual to help you locate different types of information.

Indicates information of particular interest for efficient and convenient opera- tion of the product.

1, 2, 3...

Indicates lists of one sort or another, such as procedures, precautions, etc.

OMRON, 1991

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permis- sion of OMRON.

No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the informa- tion contained in this publication.

Page 5 of the Omron Programmable Terminal (NT20M) user manual — About this Manual:
Page 5 · click to enlarge
Page 5

About this Manual:

This manual describes the installation and operation of the Support Tool and includes the sections described below. The Support Tool is a software package for creating and managing displays for the NT20M and NT600M Programmable Terminals (PTs).

Please read this manual completely and be sure you understand the information provided before at- tempting to install and operation the Support Tool.

Section 1 provides an overview of Support Tool operation and its operating environment. Basic oper- ating and input methods common to most Support Tool features are covered. The last section, Tool Settings, describes how to set Support Tool operating parameters, which affect overall operation.

Section 2 describes the specific operations used to create displays for Programmable Terminals. Special features include numeral displays, character string displays, lamps, and bar graphs, all of which can be used to display on-screen data transferred to the PT from the PT’s host, and numeral editing and touch switches, both of which can be used to input data on-screen for transfer to the host from the PT.

Section 3 describes how to manage screens as whole units.

Section 4 describes how to manage files.

Section 5 describes how to print screen images.

Section 6 describes the setup and methods for transferring data between the Support Tool and the PT. This section also includes remote operations for deleting screens from the PT.

Section 7 describes the setup and methods for transferring data between the Support Tool and a PROM writer.

The Appendix provides a table of English character codes.

Page 6 of the Omron Programmable Terminal (NT20M) user manual — SECTION 1 Introduction
Page 6 · click to enlarge
Page 6

SECTION 1 Introduction

This section outlines the operations of the Support Tool. It includes general operating procedures and installation proce- dures, as well as miscellaneous information, such as the functional limitations when creating screens for older PT mod- els. Refer to the other sections in this manual for details on specific operations. Reference pages are given in this section for many operations.

1-1 Terminology and NT-series Manuals 2 1-2 Using Older Models 2 1-3 System Configuration 3 1-3-1 NT20M and NT600M Support Tool Operations 3 1-3-2 Menu Configuration 3 1-3-3 Support Tool System 4 1-4 Creating a Work Disk 4 1-5 Starting and Exiting 5 1-6 Main Menu 5 1-7 File Selection 6 1-8 Screen Selection 7 1-9 Inputting Screen Comments, File Names, and Titles 10 1-9-1 Screen Comments 10 1-9-2 File Names and Titles 10 1-10 Editing Screens 11 1-11 Inputting Character Strings and Numbers 12 1-12 Basic Operation 13 1-12-1 Cursors 13 1-12-2 Screen Buttons 14 1-12-3 Mouse 14 1-12-4 Positioning Operations 14 1-13 Tool Settings 15 1-14 Environment Settings 16 1-15 Direct Connection 17 1-15-1 Specifying PC Addresses for Direct Connection 18 1-15-2 Direct Connection Information 19

Page 7 of the Omron Programmable Terminal (NT20M) user manual — 1-2 Using Older Models
Page 7 · click to enlarge
Page 7

Using Older Models Section 1-2

1-1 Terminology and NT-series Manuals

Names of items in this manual related to the NT Series of Programmable Ter- minals and SYSMAC C-series Programmable Controllers are defined next.

Abbreviations The following abbreviations are used in the text.

AbbreviationTermMeaning PTProgrammable TerminalRefers to an OMRON NT-series Programmable Terminal. PCProgrammable ControllerRefers to an OMRON SYSMAC C-series or CV-series Programmable Controller, or programmable controllers manufactured by other companies. I/FinterfaceA communications device that connects the Programmable Terminal with peripheral devices. I/Oinput/outputRefers to PT and PC inputs and outputs.
TerminologyExplanation SYSMACA generic name for OMRON’s Programmable Controllers. Host Link System (SYSMAC WAY)A system employing SYSMAC C-series Host Link Units used to create a communications bus between PCs, between PCs and PTs, etc. SYSMAC BUSA remote I/O network created between SYSMAC C-series PCs and input/output devices.

Reference Manuals The NT20M/NT2000M Series and NT600M Series are covered in the six manuals described below. Actual manual numbers also include suffixes indi- cating the version of the manual.

Name of ManualContentsManual No. NT20M/NT2000M Operation ManualThis manual provides specifications, functions, and operating instructions for the NT20M and NT2000M Programmable Terminals.V001 NT600M Operation ManualThis manual provides specifications, functions, and operating instructions for NT600M Programmable Terminals.V002 NT-series Host Interface Unit Operation ManualThis manual covers the commands, controls, and communications specifications for operating the NT20M and the NT600M. Refer to this manual when programming host computer communications.V003 NT20M/NT600M Support Tool Operation ManualThis manual covers methods for creating screens, including screen data preparation, switches, lights, and alarms.V004 NT-series Host Interface Unit Direct Operation ManualThis manual covers the Direct Connection feature which has been added to the Host Interface Unit.V015 NT-series RS-232C/RS-422 Interface Unit Operation ManualThis manual covers the commands, controls, and communications specifications for operating the NT20M and the NT600M with the RS-232C/RS-422 Interface Unit. Refer to this manual when programming host computer communications.V016

1-2 Using Older Models

The NT Series of Programmable Terminals is constantly being improved to better serve the needs of our customers. This manual describes features available for the newest PTs. Not all of these features are available with pre- vious versions of the Host Interface Units and System ROM, as shown in the following table. Refer to your PT’s operation manuals for details on limitations when using older models.

SYSMAC Terminology

Page 8 of the Omron Programmable Terminal (NT20M) user manual — 1-3-2 Menu Configuration
Page 8 · click to enlarge
Page 8

System Configuration Section 1-3

Host Interface Unit and/or System ROMUnsupported features Host Interface Units NT20M-LK201-EV1 NT20M-LK202-EV1 NT20M-LK203-EV1 NT20M-RT121-EV1 System ROM NT600M-SMR01-ELamps and touch switchesLamp flashing for bit input designations Round lamp displays 3D frame displays for touch switch Reverse video display for touch switch inputs Mark input for labels Bar graphsVertical displays Enlarged display widths (2 to 255 dots) +/– displays Enlarged percentage displays Numeral displaysEnlarged displays Increased display quantity (50) Numeral tablesKeypad layout designations Increased quantity (50) Stand-alone operation Backlight red/white color changes and light/flash designations

1-3 System Configuration

The NT20M/NT600M Support Tool is a software package for creating and maintaining display Screens, memory tables, and custom characters (called marks) for the NT20M and NT600M Programmable Terminals. The Support Tool uses a complete system of menus to facilitate operation.

1-3-1 NT20M and NT600M Support Tool Operations

The Support Tool can be used to create and modify screens, memory tables, and marks, and save resulting data as files. Data created on the Support Tool can be transmitted to the NT20M or NT600M Programmable Terminal. In ad- dition, the Support Tool can receive data from a Programmable Terminal, or data created on the Support Tool can be transmitted to a PROM writer. Also, the Support Tool can receive data from PROM writers. The Support Tool can read history records stored in a Programmable Terminal, and save them in files.

1-3-2 Menu Configuration

File Selection Screen Selection

Copy Delete Print Title Change ROM History Transmit Receive Initial Screen Change Capacity Change Title Tool Settings

Copy Delete Print Attributes Reading from other Files Table Edit Transmit Receive Continuous/Overlapping Screens Check Marks Change Comment Direct Connection Settings

Input String Numeral Display String Display Lamps Touch Switches Bar Graphs Table Editing Numeral Editing Graphics Marks Edit Extended Functions Environment Settings

See page 15 for specific settings.

Show 5 more labels / short text on this page
Edit Screen · Editing · Main Menu · Tool Settings · Exit
Page 9 of the Omron Programmable Terminal (NT20M) user manual — A > C:
Page 9 · click to enlarge
Page 9

Creating a Work Disk Section 1-4

1-3-3 Support Tool System

ModelNT20M-ZA5AT-EV4 System disk3.5-inch (2DD) and 5-inch (2HD) disks Applicable computersIBM PC/AT or IBM PC/AT compatible (note 1) Floppy disk drives necessaryOne min. (note 2) Graphic monitorVGA PrinterEpson dot matrix or HP laser printer PROM writerCommercially available PROM writer (note 3) MouseSerial mouse (note 4) MS-DOSVersion 3.3 or later
2. The Support Tool can also use built-in RAM or a hard disk. 3. The following communications settings must be supported. The Intel HEX file format can be used. Baud rate: 9,600 bps Stop bits: 1 bit Data length: 8 bits Parity: None 4. The mouse.com file must be installed before using the Support Tool with a mouse.

1-4 Creating a Work Disk

It is recommended that you backup the Support Tool either onto floppy disks or onto your hard disk, store the originals (the floppy disks, hereafter referred to as the “master disks”) and use the backup disks (hereafter referred to as the “work disks”) for routine work. The method for backing up onto a hard disk is explained below. If there are any points pertaining to MS-DOS which are unclear, please refer to your MS-DOS manual.

1, 2, 3... 1. Turn on the power to your computer, and start up MS-DOS.

C >

2. Insert the master disk into the floppy disk drive and switch to drive A. (Input the underlined part from the keyboard.)

C > A:

3. Type NTINSTALspaceC:return to designate the drive onto which the Support Tool is to be installed, i.e., the work disk.

A >NTINSTAL C:

or From the A: drive, it is possible to designate the C: drive directory.

A >NTINSTAL C:\NT\

4. If the installation program is successfully completed, then the Support Tool will be installed in the NT directory on the work disk. Switch from the A: drive to the C: drive. In the C: drive, switch to the NT directory.

A > C:

C >CD \NT

Page 10 of the Omron Programmable Terminal (NT20M) user manual — 1-6 Main Menu
Page 10 · click to enlarge
Page 10

Main Menu Section 1-6

5. Input NTMreturn to start and use the Support Tool.

C > NTM

This completes the backup. When starting up the next time, change directo- ries to the NT directory and then input “NTM” to start the Support Tool.

C > NTM C >CD \NT

1-5 Starting and Exiting

Startup Procedure If working from a floppy, insert the start-up disk into disk drive A and a data disk into disk drive B, then turn on the power. When using a hard disk, first start up MS-DOS from the hard disk, then input NTMreturn from the NT di- rectory. When the Support Tool has started, the following display will appear.

Omron Programmable Terminal (NT20M) — C > NTM C >CD \NT diagram (page 10)
Fig. 3

disks from the floppy disk drive or an operation error will result.

Exiting While the Main Menu is displayed, use the Up Key or the Down Key to move the bar cursor to Exit, and then press the Enter Key. The MS-DOS prompt will be displayed. At this point, eject the floppy disks and turn off the power to the computer. Always be sure to follow this procedure when exiting the Sup- port Tool.

1-6 Main Menu

When you start up the Support Tool, the Main Menu will displayed and the following items will be available.

ItemFunctionPage Edit ScreenWhen you select Edit Screen from the Main Menu, you can manage files and manipulate and edit screens.15 Tool SettingsWith this item you select the Programmable Terminal, set the memory capacity, specify the printer to be used, and make other settings. Perform this operation first. The values that you set here are saved, so there is no need to reset them unless you want to make a change.11 ExitSelect Exit from the Main Menu when you want to exit the Support Tool. Be sure to exit in this way when Support Tool operations are finished.5

Main Menu · Main Menu Items

Page 11 of the Omron Programmable Terminal (NT20M) user manual — File Selection Section 1-7
Page 11 · click to enlarge
Page 11

File Selection Section 1-7

1-7 File Selection

When you select Edit Screen from the Main Menu, the File Selection Display is displayed. Move the bar cursor to the desired file name and press the En- ter Key, or click the desired file name once to move the bar cursor and then again to open the file.

Each file contains screen data, memory table data (for numeral and charac- ter string tables), and mark data for a maximum of 250 screens for the NT20M or 1,000 screens for the NT600M. When you want to create a new file, select NEW_FILE. The Screen Selection Display will then appear to se- lect from and a file name and title are input when returning to the File Selec- tion Display. Refer to page 10 for name and title input procedures. If you want to modify a file that has already been created, select the file that you want to modify.

The help message area will display the direct connection setting and file size for the file indicated by the bar cursor.

the direct connection setting turned OFF are read when the Tool Settings is set to ON, the screens will be converted to direct connection data. It is not possible to convert from direct connection data to data without direct connec- tion.

Omron Programmable Terminal (NT20M) — File Selection Section 1-7 diagram (page 11)
Fig. 4 · File Selection Section 1-7

The EV4 version of the software can read and edit data created by the EV1. However, once the data is read by the EV4, it no longer can be read or edited by the EV1, even if the file name has not been changed. This occurs because the EV4 expands the data previously saved with the EV1. Before using any EV1 data with the EV4, it is recommended that a backup copy of the EV1 be made.

File Selection Menu

Page 12 of the Omron Programmable Terminal (NT20M) user manual — 1-8 Screen Selection
Page 12 · click to enlarge
Page 12

Screen Selection Section 1-8

File Operations You can perform file operations by using the function keys while the File Se- lection Display is being displayed.

Function keyNameFunctionPage F1CopyCopies the contents of one file to another file.96 F2DeleteCompletely deletes the contents of a file.97 F3PrintPrints screen images or data, and cross references of character string and numeral table usage.101 F4ROMTransmits data from the Support Tool to a PROM writer and receives data sent from a PROM writer to the Support Tool.117 F5History (HIST.)Receives history records from a Programmable Terminal and saves them in a file.98 F6Transmit (TMX.)Transmits screen data from the Support Tool to a Programmable Terminal. The data can be sent as file units.106 F7Receive (RCV.)Receives screen data sent from a Programmable Terminal to the Support Tool. The data can be received as file units.110 F8Initial Screen (In. Scr)Sets the screen number of the first screen to be displayed (the initial screen) when the Programmable Terminal is powered up or reset.99 F9Title Change (TITLE)Changes a file title that has previously been set.98 F10Next Functions (NEXT)Use to change the functions allocated to the function keys.--- NEXT, F1Tool Settings (TOOLS)Accesses the Tool Settings menu.15 NEXT, F10Previous Functions (PREV)Use to change the functions allocated to the function keys.---

254. Any files beyond this number cannot be accessed. If this situation occurs, use another data directory. 2. The only items displayed on the File Selection Display are the models and memory capacity that have been set with Tool Settings. For example, if the NT20M is set as the model and 32 KB is set as the memory, then NT600M files and 64 KB or 128KB NT20M files will not be displayed. Use the Memory Capacity Function Key to alter the memory capacity data set in the file.

1-8 Screen Selection

When you select either NEW_FILE or an existing file from the File Selection Display, the Screen Selection Display is displayed. If you select an existing file, the Screen Listing for that file is displayed. Move the bar cursor to the desired screen and press the Enter Key, or click the desired screen once to move the bar cursor and then again to edit the screen.

Screen numbers may be from 1 to 250 for the NT20M and from 1 to 1,000 for the NT600M. Only screen numbers 1 to 16 are displayed on the first display. Press the Pg Dn Key to see the next display, and the Pg Up Key to see pre- vious display. When creating a new screen, select a screen number for which nothing is displayed under Status in the Screen Listing.

Screen comments can be input for new screens or for changed screens when returning from the Edit Display to the Screen Selection Display. Refer to page 10 for input procedures.

Page 13 of the Omron Programmable Terminal (NT20M) user manual — Screen Selection Section 1-8
Page 13 · click to enlarge
Page 13

Screen Selection Section 1-8

Omron Programmable Terminal (NT20M) — Screen Selection Section 1-8 diagram (page 13)
Fig. 5 · Screen Selection Section 1-8

Screen Status Symbols displayed in the status column (A to E, !) express screen attribute settings for the each screen. Symbols displayed in the status column are ex- plained in more detail in the Screen Status box, which is in the lower right-hand corner of the screen.

Symbol Screen status Meaning

(Blank) No data Indicates a screen for which no data has been created.

! Data exists Indicates a screen for which data has been created.

A A: Cont Indicates a parent screen for continuous screens.

A: Ovlp Indicates a parent screen for overlapping screens.

B B: Buzz Continuous sound is set as the buzzer attribute.

B: Beep Intermittent sound is set as the buzzer attribute.

C C: Err History attribute is set.

D D: Bit Bit input attribute is set.

E E: Alrm Alarm attribute is set.

F F:Keypad Indicates a keypad has been set for numeral editing.

G G:Extend Indicates that the backlight has been set to red or that the backlight has been set to flash for the NT20-DT131/DN131.

Screen Selection Display

Page 14 of the Omron Programmable Terminal (NT20M) user manual — Screen Selection Section 1-8
Page 14 · click to enlarge
Page 14

Screen Selection Section 1-8

You can perform screen operations by using the function keys while the File Selection Display is displayed.

Function key Name Function Page

F1 Copy Copies previously created screen data to another screen number. 90

F2 Delete Deletes designated screen data. Can also be used to delete multiple screens, or to delete screens from the Programmable Terminal one screen at a time.

F3 Print Prints designated screen data. Can also be used to print multiple screens.

F4 Attribute Change (ATTRIB)

Sets buzzer attributes, bit inputs, history records, and alarms. 78

F5 Read Loads screen data from other files. The data can include screens, marks, the numeral table, the character string table, I/O comments, and direct connection information.

F6 Transmit (TMX.) Transmits data from the Support Tool to a Programmable Terminal. The data to be transmitted can be a single screen, multiple screens, or a memory table.

F7 Receive (RCV.) Receives data sent from a Programmable Terminal to the Support Tool. The data to be received can be a single screen, multiple screens, or a memory table.

F8 Continuous or Overlapping Screen Creation (Co/Ovl)

Creates Continuous or Overlapping Screens. 75

F9 Marks (MARK) Creates and modifies marks. 82

F10 Next Item (NEXT) Use to change the functions allocated to the function keys. ---

NEXT, F1 Comment Change (CMNT)

Changes screen comments that have previously been set. 92

NEXT, F2 Table Edit (TABLE) Edits memory tables 59

NEXT, F3 Check (CHECK) Checks whether there are any errors in continuous or overlapping screens, and displays or prints the results.

NEXT, F4 Direct Connection (DIRECT)

Sets data area allocations, comments, and other information for use with direct connection operation. This function key appears only if direct connection has been turned ON in the Tool Settings.

NEXT, F10 Previous Item (PREV) Use to change the functions allocated to the function keys. ---

Tags can be used to handle multiple screens simultaneously. For example, several screens can be deleted at the same time by tagging them and then executing Delete from the Screen Selection Display.

Use the following keys to attach or remove tags.

Omron Programmable Terminal (NT20M) — Screen Selection Section 1-8 diagram (page 14)
Fig. 6 · Screen Selection Section 1-8

Space Reverses the tag of the screen with the bar cursor.

Tags are indicated by asterisks. By using tags effectively, you can handle multiple screens as a single group.

Screen Selection Operations · 91, 114 · Handling Multiple Screens

Page 15 of the Omron Programmable Terminal (NT20M) user manual — 1-9-2 File Names and Titles
Page 15 · click to enlarge
Page 15

Inputting Screen Comments, File Names, and Titles Section 1-9

1-9 Inputting Screen Comments, File Names, and Titles

Screen comments, file names, and file titles can be input whenever new screens are created or when existing screens are modified. The methods for inputting these are described in this section.

1-9-1 Screen Comments

Screen comments can be input or changed when shifting from the Edit Dis- play to the Screen Selection Display. Use the following procedure.

1, 2, 3... 1. Press the Escape Key from the Edit Display after creating a new screen or editing an existing one. A message will appear asking you to confirm returning to the Screen Selection Display.

2. To confirm and to save the new screen data, press the Enter Key. To return to the Screen Selection Display without saving the new data, press the Space Key. To cancel returning to the Screen Selection display and continue editing screen data, press the Escape Key.
3. If the Enter Key is pressed to return to the Screen Selection Display, an input area will appear for the screen comment. If you have modified an existing screen, any comment previously input for it will appear. Input or change the comment as desired (24 characters) and press the Enter Key. Press the Escape Key to return to step 2.

1-9-2 File Names and Titles

File names and titles can be input when shifting from the Screen Selection Display to the File Selection Display. Use the following procedure.

1, 2, 3... 1. Press the Escape Key from the Screen Selection Display after creating new screens and/or editing existing ones. A message will appear asking if the new data should be saved.

2. To confirm and to save the new screen data, press the Enter Key. To return to the File Selection Display without saving the new data, press the Space Key. To cancel returning to the File Selection Display and return to the Screen Selection Display, press the Escape Key.
3. If the Enter Key is pressed to return to the File Selection Display, an input area will appear for the file name. Input the file name (8 characters) and press the Enter Key. Press the Escape Key to return to step 1.
4. If you specify an existing file name, you will be asked to confirm overwriting the file. Press the Enter Key to confirm overwriting or press any other key to return to step 3.
5. After the file name is input, and input area for the title will appear. Input the title as desired (28 characters) and press the Enter Key. Press the Escape Key to return to step 1.

Data will be saved to the specified file when the Enter Key is pressed for the title input step. The display, however, will not change until the operation is completed, at which time the File Selection Display will appear.

Page 16 of the Omron Programmable Terminal (NT20M) user manual — Editing Screens Section 1-10
Page 16 · click to enlarge
Page 16

Editing Screens Section 1-10

1-10 Editing Screens

If you select a screen number from the Screen Selection Display, the Initial Edit Display will be displayed. If the NT20M has been selected with Tool Set- tings, then the NT20M screen image display area will be shown in the rectan- gular box at the top of the display. If the NT600M has been selected, then the entire display becomes a display area and this box will not appear.

Omron Programmable Terminal (NT20M) — Editing Screens Section 1-10 diagram (page 16)
Fig. 7 · Editing Screens Section 1-10

Screen Edit Operations The following operations can be performed on the Edit Display.

Input string (STR IN)

Inputs character strings to be displayed on the screen and sets their display positions and the manner in which they are to be displayed. Character strings input in this way are treated as fixed displays, and their displays cannot be changed while the Programmable Terminal is operating.

Numeral display (NUM DISP)

Sets numeric displays for the screen by designating the numeral table entry to be referenced at the time of display, the display position, and the method of display.

String display (STR DISP)

Sets character string displays for the screen by designating the string table entry to be referenced at the time of display, the display position, and the method of display.

Lamps (LAMP) Sets lamps for the screen by designating the size/shape of lamp areas, numbers, and labels. 40

Touch switches (TOUCH SW)

Sets touch switches for the screen by designating the size of touch switch areas, numbers, and labels.

Bar graphs (BAR GRPH)

Sets bar graphs for the screen by designating the numeral table entry to use, the display positions/directions, and the method of display. The display of percentage calculations is also set.

Table editing (TBL EDIT)

Edits numeral table and character string table contents, and is the same as the table editing operation entered from the Screen Selection Display.

Numeral editing (NUM EDIT)

Creates screens for numeric input via function keys, touch switches, or Expansion I/O Units (32/16 Terminals or Function Key Units (12 keys)) and designates the numeral table to which the input will be written.

Polylines (a broken line made up of one or more line segments) and circles can be created on screen.

Marks (MARK) Creates and modifies marks. 82

Edit (EDIT) Copies, moves, or deletes text or graphics on the screen. 87

Initial Edit Display · Item Function Page · Graphic input (GRAPHIC)

Page 17 of the Omron Programmable Terminal (NT20M) user manual — 1-11 Inputting Character Strings and Numbers
Page 17 · click to enlarge
Page 17

Inputting Character Strings and Numbers Section 1-11

Omron Programmable Terminal (NT20M) — Inputting Character Strings and Numbers Section 1-11 diagram (page 17)
Fig. 8 · Inputting Character Strings and Numbers Section 1-11

Enables usage of stand-alone operation. In stand-alone operation, screens can be changed from PT touch switches/function keys or from Expansion I/O Units.

Sets data area allocations, comments, and other information for use with direct connection operation. This function key appears only if direct connection has been turned ON in the Tool Settings.

Accesses a modified version of the Tool Settings to enable changing certain Support Tool operating parameters during operation.

Changing Menu Position and Grid Display

While creating data for the NT600M, there may be times when the screen data and the menu box overlap, making it difficult to see what you are doing. In such cases, you cam move or delete the menu box. The grid display can also be turned ON and OFF for either the NT600M or NT20M by pressing the Delete Key as long as grid display has been enabled in the tool settings (See page 15). The display position of the menu box and will change each time you press the Home Key as shown in the following tables.

NT600M with Grid Enabled

Omron Programmable Terminal (NT20M) — Changing Menu Position and Grid Display diagram (page 17)
Fig. 9 · Changing Menu Position and Grid Display

NT600M with Grid Disabled

Delete Key inputs Initial 1 2 3

Menu Bottom Top None Bottom

Grid OFF

NT20M

Delete Key inputs Initial 1 2

Menu Bottom Bottom Bottom

Grid ON OFF ON

2. Screen data cannot be created and you cannot switch to the Screen Selection Display unless the menu is displayed.

1-11 Inputting Character Strings and Numbers

Inputting Character Strings You can use the Left, Right, Backspace, Delete, Insert, and Escape Keys when inputting character strings. Their functions are described below.

Moves the cursor to the left.

Moves the cursor to the right.

BS Deletes one character to the left of the cursor.

DEL Deletes one character at the cursor position.

INS Switches between insert mode and overwrite mode.

ESC Cancels character input string and returns to previous operation.

In insert mode, the cursor becomes a flashing rectangle and character strings are inserted at the cursor position. When text is inserted in this way, character strings to the right of the cursor position move to the right.

Page 18 of the Omron Programmable Terminal (NT20M) user manual — 1-12-1 Cursors
Page 18 · click to enlarge
Page 18

Basic Operation Section 1-12

In overwrite mode, the cursor becomes a reversed rectangle and character strings delete previously input characters at the cursor position.

Inputting Numbers Inputting numbers is basically the same as inputting character strings, except that you cannot change between insert mode and overwrite mode with the Insert Key. The overwrite mode is always used.

The Home Key can be used to change to 0 any numbers previously input, and the Minus (–) Key can be used to change between positive and negative numbers.

Control Key Combinations The Control Key can be used in combination with other keys to move the cur- sor, delete characters, and achieve other operations. These combinations are shown in the following table.

CTRL + S Left Cursor Key

CTRL + D Right Cursor Key

CTRL + E Up Cursor Key

CTRL + X Down Cursor Key

CTRL + R Page Up Key

CTRL + C Page Down Key

CTRL + H Backspace Key

CTRL + G Delete Key

CTRL + I Tab Key

CTRL + M Enter Key

CTRL + [ Escape Key

1-12 Basic Operation

1-12-1 Cursors

Several different cursors will appear depending on Support Tool operation. Special cursors are described in the following table.

The arrow cursor is used in combination with the cursor to specify menu items and icons. Refer to page 14 for details on the mouse.

A cup will appear when the Support Tool is accessing data on the disk. When accessing has finished, the arrow cursor will return.

A question mark will appear when the Support Tool is waiting for a Yes/No response from the user. Press the Enter Key or the left mouse button to answer Yes (confirm) or press the Escape Key or right mouse button to answer No (cancel).

A hand and keyboard will appear at the end of processing to request user acknowledgement. Press any key or either mouse button to continue operation.

Keys Same as · Cursor Meaning

Page 19 of the Omron Programmable Terminal (NT20M) user manual — 1-12-4 Positioning Operations
Page 19 · click to enlarge
Page 19

Basic Operation Section 1-12

1-12-2 Screen Buttons

There are many buttons in the shape of keys that can appear during Support Tool operation. These buttons can be clicked with the mouse to achieve the same operation as the equivalent keyboard keys. Included are the Enter Key (carriage return arrow), Escape Key, cursor keys, PgUp Key, PgDn Key, Space Bar, Shift+Home (clear) Key (one button combining two keys), the Home (clear) Key, and function keys.

1-12-3 Mouse

A mouse can be connected to the Support Tool and used to input coordinates to specify display positions for text strings or numerals and to create poly- lines, circles, and other graphics.

To use a mouse, connect a two-button mouse to the computer’s mouse con- nector and prepare a level, smooth surface, such as a mouse pad, to operate it on. The mouse can then be used to move labels, the + cursor, and other objects on the screen (see below).

Procedures in this manual are generally written for operation from the key- board. There are, however, often three means to execute an operation, i.e., from the keyboard, using on-screen buttons, and using the mouse and cursor directly. It is generally a matter of preference on which method is used; the results will be the same.

Left Button The left mouse button can be used in place of the Enter Key to achieve the following.

  • To specify items on menus. Click the mouse once to move the cursor and then again to execute.
  • To click on-screen buttons to replace keyboard key inputs. See page 14 for details.
  • Double-clicking to end polyline input (instead of Shift + Enter).
  • Dragging to move objects on screen or draw lines.
  • To designate display positions for text or numerals
  • To designate display positions for touch switches, lamps, and bar graphs
  • To designate center, start, and end points for graphics

Right Button The right mouse button can be clicked in place of pressing the Escape Key to move backward through processing steps or to cancel an operation.

some operations have been restricted to only keyboard operation for safety. If the software does not respond when a mouse button is pressed, use the key- board instead.

1-12-4 Positioning Operations

Grid display can be set via the Tool Settings, and grid display and snap-to- grid operation can be set via the Set Environment settings. The grid can be used either to visually align objects on the display or it can be combined with snap-to-grid operation to force objects to be positioned exactly on the grid. Refer to pages 15 and 16 for details.

Page 20 of the Omron Programmable Terminal (NT20M) user manual — Tool Settings Section 1-13
Page 20 · click to enlarge
Page 20

Tool Settings Section 1-13

1-13 Tool Settings

If you start up the Support Tool and select Tool Settings from the Main Menu, the Tool Settings Display will appear.

Omron Programmable Terminal (NT20M) — Tool Settings Section 1-13 diagram (page 20)
Fig. 10 · Tool Settings Section 1-13

Contents of Tool Settings

NT Model Sets the model of Programmable Terminal being used.

Memory Size Sets the memory capacity of the Programmable Terminal.

Direct Setting Turns ON and OFF the direct connection operation. Refer to page 17 for details.

Printer Sets the printer model to be used.

Sheet Feeder Sets a sheet feeder for the printer.

Auto Refresh Sets whether or not the screen will be automatically refreshed when you make screen data additions, deletions, or modifications.

Display Grid Controls the grid display. If “TouchSW” is specified, each grid unit will be the size of a touch switch.

Specify the port on the computer to be used to communicate with the PT. If possible, do not specify the same port as the one used for the mouse.

Sets the file name for the work file that is temporarily used by the Support Tool.

Data Directory Sets directory names for saving screen data which is created.

Press the Enter Key when you want to save the contents of the Tool Settings. Then either press the Enter Key again to return to the Main Menu, or press the Escape Key to return to the Tool Settings Display to correct settings.

If you press the Space Key, the tool settings will be changed without being saved to a file, and you will be returned to the Main Menu.

Press the Escape Key to cancel changing tool settings.

Auto Refresh When screen data is added, deleted, or modified with the Support Tool, the screen display may be temporarily disordered. If Auto Refresh is set to “Yes,” then the screen display will be automatically rewritten when you return to the Initial Edit Screen. When creating large amounts of screen data, however, some time may be required for screen refreshing. Auto Refresh can be set to

Name Content · Communication Port · Temporary Directory

Page 21 of the Omron Programmable Terminal (NT20M) user manual — 1-14 Environment Settings
Page 21 · click to enlarge
Page 21

Environment Settings Section 1-14

“No” to save time. You can manually rewrite the screen by pressing the Tab Key during operation.

Temporary Directory The Support Tool will create a temporary work file when creating screens or transferring data to or from ROM. Most write operations are performed on this temporary file. To increase overall operating speed, this file should be created on your hard disk or in RAM.

Tool Settings File File settings are saved in the root directory for the Support Tool, i.e., the di- rectory from which the Support Tool is started. The file name is NTMSET.ENV. If this file exists in the root directory when the Support Tool is started, the setting in the file will be read and the Support Tool will operate according to them. Tool settings files can be used to eliminate the need to reset tool setting each time the Support Tool is started.

Display Grid A grid can be displayed to aid in positioning objects when creating screens. The Tool Settings can be used to disable the grid or to set its size to 8, 16, or 32 dots. The grid size can also be set to the same size as a touch switch by specifying “TouchSW.” The grid, once enabled, can be turned ON or OFF as desired during operation. Refer to page 12 for details.

1-14 Environment Settings

A modified version of the Tool Settings can be accessed from the Initial Edit Display. The following display will appear when SET ENV is specified.

Omron Programmable Terminal (NT20M) — 1-14 Environment Settings diagram (page 21)
Fig. 11 · 1-14 Environment Settings

Set the PT operating environment as described in the following table.

Page 22 of the Omron Programmable Terminal (NT20M) user manual — 1-15 Direct Connection
Page 22 · click to enlarge
Page 22

Direct Connection Section 1-15

Display grid No Display grid is not displayed. y g

Display grid is displayed at the specified width. Screen objects can be snapped to the grid if one of these settings is made and the snap ON function is turned ON (see below).

Display grid is displayed at the minimum width for touch switches. This setting is useful to draw lamps to the same size as touch switches. It functions the same way as the other grids.

Off Allows graphics to be drawn and screen objects to be positioned without interference from the grid, i.e., the grid, if displayed, is used only as a visual guide.

On Allows graphics to be drawn and screen object to be positioned only to the intersection points of the grid.

Lamp/touch switch number di l

No Lamp/touch switch numbers or bit addresses are not displayed. display 1/16 1/4 Indicates lamp/touch switch specifications and the allocated lamp/touch switch number or the allocated PC bit on the display at the specified character size.

For example, “LH001015” would be displayed for a lamp display allocated to HR 1015 using direction connection, “TA001012”would be displayed for a touch switch display allocated to AR 1012 using direction connection, L000 would be displayed for lamp #0 when not using direction connection, and T010 would be displayed for touch switch #10.

No Memory table entry numbers are not displayed. y entry number display 1/16 1/4 Indicates the allocated memory table number on the display at the specified character size for numeral displays, character string displays, bar graphs, and numeral editing areas. “N” is also displayed for numeral table entry numbers and “S” is displayed for character string table entry numbers.

1-15 Direct Connection

The PT can be set for direct connection to an OMRON PC to allow numeral displays, character displays, numeral editing, lamps, touch switches, and bar graphs to be directly connected to specific bits and words in PC memory. Bits can also be set that will change the displayed screen. This is possible only when the NT600M-DT121/DT211 or NT20M-DT121-V1/DT131 PTs and only when a NT600M-LK201 SYSMAC WAY Host Interface Unit is used. Also, either an NT600M-SMR31 or NT20M-SMR31 System ROM must be used in the PT.

The direct connection setting in the Tool Settings greatly affects the operation of the screen functions that read or write PC memory. Although using direc- tion connection will greatly reduce programming burden for the PC, careful preparation is required to coordinate PC memory and programming with the PT settings for direct connection. The general procedure for this is as follows:

1, 2, 3... 1. Design the required PT screens. 2. Allocate PC memory to the function elements of the screens, i.e., those elements that will directly read or write PC memory. Be sure to list spe- cific PC memory addresses, including areas, and to consider numeral table and character string table capacities. 3. Turn ON direct connection operation in the Tool Settings.

Show 6 more labels / short text on this page
Item Settings Setting · 8-dot 16-dot 32-dot · Touch switch · Snap ON function · Memory table · t b
Page 23 of the Omron Programmable Terminal (NT20M) user manual — F1 AR (511)
Page 23 · click to enlarge
Page 23

Direct Connection Section 1-15

4. Create the required screens, making all settings required for direct connection. 5. Save the screens. 6. Transfer the screens to the PT or write them to ROM.

Conversion Screen files that were created with direct connection turned OFF can be loaded with direct connection turned ON to convert the screens for use with direct connection. Once files are created for or converted to direct connec- tion, they cannot be loaded with direct connection turned OFF in the Tool Settings and cannot be converted back for use without direct connection.

Indication on Displays Displays on the File Selection Display and the Screen Selection display will indicate whether or not direct connection has been set. If direct connection has been set, “-O” (for OMRON) will be added after the PT model name fol- lowing the “File List” title on the File Selection Display. The help message area on the Screen Selection Display will also indicate whether or not direct connection has been used together with the file size.

1-15-1 Specifying PC Addresses for Direct Connection

The function keys are allocated as shown in the following table when specify- ing bit and word addresses in PC memory. The values in parentheses indi- cate the maximum word address possible for the largest PC memory. Actual memory sizes vary, however, with the model of PC. Refer to your PC’s opera- tion manual for specific limits.

F1 AR (511)

F2 HR (99)

F3 LR (63)

F4 DM (9999)

F5 CNT (1023)

F6 TIM (1023)

F7 CIO, IR, SR (2555) (displayed as I/S)

The areas that can be designated for direct connection are as shown in the following table.

Item Memory unit Designation

Lamps Bit IR, SR (CIO), AR, or LR bit addresses.

DM word address can also be designated with bit specifications Touch switches

bit specifications.

Timers and counters cannot be designated. (See note.)

Numeral display Word IR, SR (CIO), AR, LR, or DM word addresses.

Timer and counter numbers can also be specified to designate PVs Numeral editing specified to designate PVs.

IR, SR (CIO), AR, LR, or DM word addresses.

Timer and counter numbers cannot be specified.

switch will control the status of the specified bit and all other bits in the speci- fied word will be turned OFF (0).

Show 5 more labels / short text on this page
Key Area · Home None · ( ) · Bar graphs · Character string display
Page 24 of the Omron Programmable Terminal (NT20M) user manual — Direct Connection Section 1-15
Page 24 · click to enlarge
Page 24

Direct Connection Section 1-15

1-15-2 Direct Connection Information

Settings for the direct connection information are made from the extended functions display. Direct connection information settings will not appear on the extended function display unless direct connection is turned ON in the Tool Settings.

Use the following procedure to set the direct connection information settings.

1, 2, 3... 1. Specify EXTEND from the Initial Edit Display. The following display will appear at the bottom of the screen

Omron Programmable Terminal (NT20M) — Direct Connection Section 1-15 diagram (page 24)
Fig. 12 · Direct Connection Section 1-15
2. Specify direct connection. (F-key is not supported by PTs with touch panels and cannot be specified.) The following display will appear.
Omron Programmable Terminal (NT20M) — Direct Connection Section 1-15 diagram (page 24)
Fig. 13 · Direct Connection Section 1-15
3. Set the direct connection information as described in the following table.

PT control area Set the address of the first word in the PC to be used to control PT status. This setting must be made. A user comment may also be input if desired.

PT notify area Set the address of the first word in the PC to be used to store PT status. This setting must be made. A user comment may also be input if desired.

Numeral mem. table The contents of the numeral table used in the file can be seen in list form. Data can be input or changed.

String mem. table The contents of the character string table used in the file can be seen in list form. Data can be input or changed.

F-key input/output notify Function keys cannot be set for PTs with touch panels. These settings are not required and will be ignored if input.

4. When the settings have been completed, press the Escape Key once to return to the beginning of the operation and twice to end.

Item Setting

Page 25 of the Omron Programmable Terminal (NT20M) user manual — SECTION 2 Creating Screens
Page 25 · click to enlarge
Page 25

SECTION 2 Creating Screens

This section describes the procedures used to create and check screens and to input screen attributes. The procedures for creating special display characters, called marks, and for controlling screens during stand-alone operation are also pro- vided here.

2-1 Inputting Character Strings 22 2-1-1 New Character Strings 22 2-1-2 Deleting Character Strings 25 2-1-3 Modifying Character Strings 26 2-2 Numeral Displays 28 2-2-1 Normal Numeral Displays 28 2-2-2 Direct Connection Numeral Displays 31 2-3 Character String Displays 34 2-3-1 Normal Character String Displays 35 2-3-2 Direct Connection Character String Displays 37 2-4 Lamps 40 2-4-1 Normal Lamps 40 2-4-2 Direct Connection Lamps 43 2-5 Touch Switches 46 2-5-1 Normal Touch Switches 46 2-5-2 Direct Connection Touch Switches 48 2-6 Bar Graphs 51 2-6-1 Creating Normal Bar Graphs 52 2-6-2 Direct Connection Bar Graphs 55 2-7 Editing Memory Tables 59 2-7-1 Normal Operation 59 2-7-2 Direction Connection Operation 61 2-8 Numeral Editing 62 2-8-1 Normal Numeral Editing 63 2-8-2 Direct Connection Numeral Editing 68 2-8-3 Precautions for Numeral Editing 70 2-9 Polylines 71 2-9-1 Creating New Polylines 71 2-9-2 Deleting Polylines 72 2-9-3 Modifying Polylines 72 2-10 Circles 73 2-10-1 Creating New Circles 73 2-10-2 Deleting Circles 74 2-10-3 Modifying Circles 74 2-11 Continuous and Overlapping Screens 75 2-12 Screen Attributes 78 2-13 Screen Check 80 2-14 Marks 82 2-15 Stand-alone Operation 85 2-16 Edit 87

Page 26 of the Omron Programmable Terminal (NT20M) user manual — 2-1-1 New Character Strings
Page 26 · click to enlarge
Page 26

Inputting Character Strings Section 2-1

2-1 Inputting Character Strings

With the Character Input Display, you set characters to be displayed on the PT. You set character sizes, character scaling factors, manner of display, and display positions.

If you select STR IN from the Initial Edit Display, the Initial Character Input Display will appear.

Initial Character Input Display

Omron Programmable Terminal (NT20M) — Inputting Character Strings Section 2-1 diagram (page 26)
Fig. 14 · Inputting Character Strings Section 2-1

The following pages explain how to use this display, taking the creation of NT20M screen data as an example.

2-1-1 New Character Strings

Inputting Strings This example shows how to input the roman letters “abcde.”

You can display up to 32 characters per line on a NT20M screen, and up to 80 per line on a NT600M screen. 1, 2, 3... 1. Specify CREATE. 2. Input the characters, e.g., “abcde.” The following display will appear.

Omron Programmable Terminal (NT20M) — 2-1-1 New Character Strings diagram (page 26)
Fig. 15 · 2-1-1 New Character Strings
Page 27 of the Omron Programmable Terminal (NT20M) user manual — Inputting Character Strings Section 2-1
Page 27 · click to enlarge
Page 27

Inputting Character Strings Section 2-1

3. If the input is correct, press the Enter Key to enter the characters and go to the String Attributes section on page 24. Special characters or Marks can also be input as display characters as described below.

Special Characters Characters not on the keyboard can be input via character codes. A list of character codes is provided at the end of the manual. To input a character code, press the ALT Key followed by the decimal code.

Marks You can input marks while inputting characters.

1, 2, 3... 1. Press F1 (Mark) while inputting a string. The Mark List will appear.

Omron Programmable Terminal (NT20M) — Inputting Character Strings Section 2-1 diagram (page 27)
Fig. 16 · Inputting Character Strings Section 2-1
2. Use the direction keys to select the mark you want to input, and then press the Enter Key to enter them, or press the Escape Key to cancel mark input and return to character input.
Omron Programmable Terminal (NT20M) — Inputting Character Strings Section 2-1 diagram (page 27)
Fig. 17 · Inputting Character Strings Section 2-1
Page 28 of the Omron Programmable Terminal (NT20M) user manual — Inputting Character Strings Section 2-1
Page 28 · click to enlarge
Page 28

Inputting Character Strings Section 2-1

String Attributes Here you set the size, scale, and attributes for character strings that have been input.

Omron Programmable Terminal (NT20M) — Inputting Character Strings Section 2-1 diagram (page 28)
Fig. 18 · Inputting Character Strings Section 2-1

1, 2, 3... 1. Set the size to be used for each 1-byte character. 2. Set the scale factor for the characters. NT600M strings can be set to 64X in addition to the ones shown in the above display. 3. Set display attributes. “Spot” is for flashing characters in reverse video. Display attributes will be displayed on the computer screen as shown below. (Although the contrast of most displays in this manual is re- versed, the contrast of these examples is the same of that on the screen.

Inverse Spot (Inverse Blinking)

Omron Programmable Terminal (NT20M) — Inputting Character Strings Section 2-1 diagram (page 28)
Fig. 19 · Inputting Character Strings Section 2-1
4. Press the Enter Key after checking the settings.

A display for designating string position will appear next.

Designate the display position for the string.

1, 2, 3... 1. A rectangular guide box showing the size of the input character string will be displayed. The guide box is displayed according to the number of characters input to that point, and the scale which has been set. Set the display position on the screen with the direction keys. By operating the direction keys while pressing the Shift Key, you can move the guide box 16 dots at a time. The X and Y coordinates of the display position (the X and Y coordinates of the lower left-hand corner of the guide box) are

Normal Flashing · Designating Display Position

Page 29 of the Omron Programmable Terminal (NT20M) user manual — 2-1-2 Deleting Character Strings
Page 29 · click to enlarge
Page 29

Inputting Character Strings Section 2-1

displayed. You cannot set a display position that allows the guide box to extend off the screen.

Omron Programmable Terminal (NT20M) — Inputting Character Strings Section 2-1 diagram (page 29)
Fig. 20 · Inputting Character Strings Section 2-1
2. When you have set the display position, press the Enter Key.
Omron Programmable Terminal (NT20M) — Inputting Character Strings Section 2-1 diagram (page 29)
Fig. 21 · Inputting Character Strings Section 2-1
3. You will be returned to the Initial Text Input Display, and the contents set up to this point are displayed. At this time, a message again appears in the command box instructing you to enter text. If you are inputting text to different places on the same screen, repeat the operations described above. When you have finished inputting text, press the Escape Key. You will be returned to the Initial Edit Display.

2-1-2 Deleting Character Strings

You can delete strings that have already been set by using the procedure given below. When you delete a string, a portion of the display may be left empty. If this happens, press the TAB Key to rewrite the display.

Guide box · Cross-shaped cursor

Page 30 of the Omron Programmable Terminal (NT20M) user manual — 2-1-3 Modifying Character Strings
Page 30 · click to enlarge
Page 30

Inputting Character Strings Section 2-1

1, 2, 3... 1. Specify DELETE. The cross-shaped cursor will be displayed.

Omron Programmable Terminal (NT20M) — Inputting Character Strings Section 2-1 diagram (page 30)
Fig. 22 · Inputting Character Strings Section 2-1
2. Line up the center of the cross-shaped cursor with the string you want to delete, and press the Enter Key. The string which you have selected will be outlined by a guide box. A message will appear in a comment box to verify whether you actually want to delete that string. If a number of characters have been input at one time, then it makes no difference which character you place the cross-shaped cursor on.
Omron Programmable Terminal (NT20M) — Inputting Character Strings Section 2-1 diagram (page 30)
Fig. 23 · Inputting Character Strings Section 2-1
3. To delete the string, press the Enter Key, or to cancel, press any key other than the Enter Key.

The basic delete operation for other data on the Edit Display, e.g., numeral displays, is the same.

rescan the display.

2-1-3 Modifying Character Strings

You can modify strings that have already been set.

Page 31 of the Omron Programmable Terminal (NT20M) user manual — Inputting Character Strings Section 2-1
Page 31 · click to enlarge
Page 31

Inputting Character Strings Section 2-1

1, 2, 3... 1. Press MODIFY. The cross-shaped cursor will be displayed.

Omron Programmable Terminal (NT20M) — Inputting Character Strings Section 2-1 diagram (page 31)
Fig. 24 · Inputting Character Strings Section 2-1
2. Line up the center of the cross-shaped cursor with the string you want to change, and press the Enter Key. The character which you have selected will be outlined by a guide box, and at the right of the screen a box will be displayed for you to select the items to be modified.
Omron Programmable Terminal (NT20M) — Inputting Character Strings Section 2-1 diagram (page 31)
Fig. 25 · Inputting Character Strings Section 2-1

3. Use the Up and Down Keys to select the item to modified, and then press the Enter Key. You can return to step 2 by pressing the Escape Key. For items selected for change, data input methods are the same as when the string was created. 4. To end the modification, press the Escape Key. A message will appear asking whether you want to save the modified contents. 5. Press the Enter Key to save any changes made, or if you do not wish to save the modified contents, press the Space Key to cancel all modifica- tions and restore the previous data. 6. To return to step 3, press the Escape Key.

The procedure for modifying data with the Edit Display is the same as that for other functions such as numeral and character displays.

Page 32 of the Omron Programmable Terminal (NT20M) user manual — 2-2-1 Normal Numeral Displays
Page 32 · click to enlarge
Page 32

Numeral Displays Section 2-2

2-2 Numeral Displays

Values from numeral tables can be displayed on a screen. The numeral table entry to be referenced, the display position, and the manner of display are set. You can set a maximum of 50 numeral displays per screen.

For the NT20M, numeral table entries are numbered from 0 to 127, for a total of 128. For the NT600M, numeral table entries are numbered from 0 to 255, for a total of 256.

The procedure for setting number displays depends on whether or not direct connection is ON or OFF in the Tool Settings. Both procedures are given be- low.

2-2-1 Normal Numeral Displays

Select NUM DISP from the Initial Edit Display, the Initial Display for Numeral Display will appear.

Initial Display for Numeral Display

Omron Programmable Terminal (NT20M) — 2-2-1 Normal Numeral Displays diagram (page 32)
Fig. 26 · 2-2-1 Normal Numeral Displays

Designating Numeral Table References

Only table number entries 0 to 13 are displayed first. To display the next en- tries, press the Pg Dn Key; to return to previous entires, press the Pg Up Key.

Select the numeral table entry that you want to reference and then press the Enter Key.

Inputting Initial Values The initial value for the selected memory table reference is input next. Refer to page 12 for details on input methods. You can input numbers from –99999999 to 99999999. Numeral displays can display decimal numbers, but you enter them here without the decimal point. For example, if you want to

Page 33 of the Omron Programmable Terminal (NT20M) user manual — Numeral Displays Section 2-2
Page 33 · click to enlarge
Page 33

Numeral Displays Section 2-2

input –123.456, then just input –123456. The distinction between the integer portion and the decimal portion is specified in the next step.

Omron Programmable Terminal (NT20M) — Numeral Displays Section 2-2 diagram (page 33)
Fig. 27 · Numeral Displays Section 2-2

Input the number, and then press the Enter Key.

Omron Programmable Terminal (NT20M) — Numeral Displays Section 2-2 diagram (page 33)
Fig. 28 · Numeral Displays Section 2-2

Set the way in which the display will appear on the screen. Refer to the ex- amples on page 30.

Numeral Display Settings

Page 34 of the Omron Programmable Terminal (NT20M) user manual — Numeral Displays Section 2-2
Page 34 · click to enlarge
Page 34

Numeral Displays Section 2-2

Reference table entry (Reference Table)

Set the number of the item to be referenced in the numeral table.

Number of integer digits (Integer)

Set the number of digits for the integer portion of the number.

Number of decimal digits (Decimal)

Set the number of digits for the decimal portion of the number.

Zero suppress (Zero Sup)

Set whether or not leading zeros are to be displayed on the screen.

Display sign (Disp Sign)

Set whether or not negative signs are to be displayed on the screen. The positive sign is not displayed.

Character size (Char Size)

Set the size of characters to be displayed on the screen.

Scale Set the scale factor for the display. The NT600M can be set to 64X in addition to those shown above.

Attributes Sets display attributes for the screen. Refer to page 24 for examples of how attributes are displayed on screen.

Press the Enter Key after checking all of these settings.

Omron Programmable Terminal (NT20M) — Numeral Displays Section 2-2 diagram (page 34)
Fig. 29 · Numeral Displays Section 2-2

Numeral Display Examples

Page 35 of the Omron Programmable Terminal (NT20M) user manual — 2-2-2 Direct Connection Numeral Displays
Page 35 · click to enlarge
Page 35

Numeral Displays Section 2-2

A guide box corresponding to the size of the numeral display will appear. Designate the display position on the screen with the cross-shaped cursor and press the Enter Key. You cannot make a setting that will cause the guide box to extend from the screen.

Omron Programmable Terminal (NT20M) — Numeral Displays Section 2-2 diagram (page 35)
Fig. 30 · Numeral Displays Section 2-2

You can delete or modify previously input numeral displays. The procedures for these operations are the same as those for deleting and modifying char- acter strings. Refer to appropriate subsections of 2-1 Inputting Character Strings for details.

2-2-2 Direct Connection Numeral Displays

Creating Use the following procedure to create a direct connection numeral display.

1, 2, 3... 1. Select NUM DISP from the Initial Edit Display, a list of the numeral dis- plays already existing in the current screen will be displayed.

Omron Programmable Terminal (NT20M) — 2-2-2 Direct Connection Numeral Displays diagram (page 35)
Fig. 31 · 2-2-2 Direct Connection Numeral Displays
2. Specify the number to be used in the table. This is not the numeral table and the numbers do not correspond to item numbers in the numeral table. When a number is specified, a display to set direct or indirect referencing will appear.

Designating Display Positions · Deleting and Modifying

Page 36 of the Omron Programmable Terminal (NT20M) user manual — Numeral Displays Section 2-2
Page 36 · click to enlarge
Page 36

Numeral Displays Section 2-2

3. Specify “Direct.” Indirect referencing is not currently supported. The numeral table will be displayed.
Omron Programmable Terminal (NT20M) — Numeral Displays Section 2-2 diagram (page 36)
Fig. 32 · Numeral Displays Section 2-2
4. Specify the desired table entry number. The initial value input field (contents) will be entered. The headings in the table are described in the following table.

No. Numeral table entry number

IN initialize at startup) Indicates whether or not the table value is to be initialized when the PT is turned ON.

# (quantity) Number of PC words used

Word Address of the first PC word

Comment User comment area

5. Input the desired initial value. This value can be omitted here if desired and input later using the table edit operation. The initial value can be up to 8 digits long. When the initial value field is left, the following display will appear to input the remaining settings.

Heading Meaning · Contents Initial value

Page 37 of the Omron Programmable Terminal (NT20M) user manual — Numeral Displays Section 2-2
Page 37 · click to enlarge
Page 37

Numeral Displays Section 2-2

Refer to page 61 for details.

Omron Programmable Terminal (NT20M) — Numeral Displays Section 2-2 diagram (page 37)
Fig. 33 · Numeral Displays Section 2-2
6. Make the four settings as described in the following table. The comment is optional and all four settings can be omitted here if desired and input later using the table edit operation.

Initialize (Init) Set YES to initialize the contents in the numeral table when PT power is turned ON. Set to NO to maintain the previous value when PT power is turned ON.

Set words (St Word) Set the number of PC words to be used.

Word Set the address of the first PC word to be used.

Comment Input any desired user comment area

The numeral display settings will appear when the above display is left.

Omron Programmable Terminal (NT20M) — Numeral Displays Section 2-2 diagram (page 37)
Fig. 34 · Numeral Displays Section 2-2
7. Set the way in which the display will appear on the screen. Refer to the examples on page 30.

Heading Meaning

Page 38 of the Omron Programmable Terminal (NT20M) user manual — 2-3 Character String Displays
Page 38 · click to enlarge
Page 38

Character String Displays Section 2-3

Number of integer digits (Integer)

Set the number of digits for the integer portion of the number.

Number of decimal digits (Decimal)

Set the number of digits for the decimal portion of the number.

Zero suppress (Zero Sup)

Set whether or not leading zeros are to be displayed on the screen.

Display sign (Disp Sign)

Set whether or not negative signs are to be displayed on the screen. The positive sign is not displayed.

Character size (Char Size)

Set the size of characters to be displayed on the screen.

Scale Set the scale factor for the display. The NT600M can be set to 64X in addition to those shown above.

Attributes Sets display attributes for the screen. Refer to page 24 for examples of how attributes are displayed on screen.

Display type (Disp Type)

Specify either decimal or hexadecimal display.

Press the Enter Key after completing all of these settings. 8. Set the display position. When the display position has been set, you can return to set another numeral display or you can continue pressing the Escape Key to return to the Initial Edit Display.

Deleting and Modifying Direct connection numeral displays are deleted or modified from the display shown in step 1. above. Select the number of the numeral table and then specify DELETE or MODIFY. The modification procedure is basically the same as the creation procedure given above.

2-3 Character String Displays

The contents of character string tables can be displayed on the screen. The string table entry to be referenced, the display position, and manner of dis- play must be set.

You can set a maximum of 8 string displays per screen for the NT20M and 50 for the NT600M.For the NT20M, string table entries are numbered from 0 to 31, for a total of 32. For the NT600M, string table entries are numbered from 0 to 255, for a total of 256.

The procedure for setting number displays depends on whether or not direct connection is ON or OFF in the Tool Settings. Both procedures are given be- low.

Page 39 of the Omron Programmable Terminal (NT20M) user manual — Character String Displays Section 2-3
Page 39 · click to enlarge
Page 39

Character String Displays Section 2-3

2-3-1 Normal Character String Displays

If you select STR DISP from the Initial Edit Display, the Initial Screen for Character String Display will appear.

Initial Display for Character String Display

Designating String Tables to be Referenced

Table entires 0 to 13 are displayed first on the screen. To display the next entires, press the Pg Dn Key; to return to previously entries, press the Pg Up Key.

Select the string table entry that you want to reference and then press the Enter Key.

Inputting Initial Value Set the initial value for the selected table entry.

Input the initial value according to the instructions for inputting the initial val- ues for numeral tables. For the NT20M, the maximum number of characters that can be registered is 32 characters. For the NT600M, the maximum num- ber of characters that can be registered is 40 characters.

Omron Programmable Terminal (NT20M) — Character String Displays Section 2-3 diagram (page 39)
Fig. 35 · Character String Displays Section 2-3

Input the characters, and then press the Enter Key.

Page 40 of the Omron Programmable Terminal (NT20M) user manual — Character String Displays Section 2-3
Page 40 · click to enlarge
Page 40

Character String Displays Section 2-3

Omron Programmable Terminal (NT20M) — Character String Displays Section 2-3 diagram (page 40)
Fig. 36 · Character String Displays Section 2-3

Set the way in which the display will appear on the screen.

Number of character digits (Char; See Note)

Set the number of character digits to be displayed on the screen.

Character size (Size) Set the character size to be used for each 1-byte characters.

Scale Set the scale for characters to be displayed on the screen. The NT600M can be set to 64X in addition to those shown above.

Display attributes (Attr.)

Set display attributes for the screen. Refer to page 24 for examples of how attributes are displayed on screen.

have been set will be displayed. Each normal character requires one digit and each mark requires 2 digits.

Press the Enter Key after checking all of the settings.

A guide box corresponding to the size of the set contents will be displayed. Designate the display position on the screen with the cross-shaped cursor Designating Display Position

Setting Display Attributes

Page 41 of the Omron Programmable Terminal (NT20M) user manual — 2-3-2 Direct Connection Character String Displays
Page 41 · click to enlarge
Page 41

Character String Displays Section 2-3

and press the Enter Key. You cannot make a setting that will cause the guide box to extend from the screen.

Omron Programmable Terminal (NT20M) — Character String Displays Section 2-3 diagram (page 41)
Fig. 37 · Character String Displays Section 2-3

Deleting and Modifying You can delete or modify previously input character string displays. The pro- cedures for these operations are the same as those for deleting and modify- ing character strings. Refer to appropriate subsections of 2-1 Inputting Char- acter Strings for details.

2-3-2 Direct Connection Character String Displays

Creating Use the following procedure to create a direct connection character string display.

1, 2, 3... 1. Select STR DISP from the Initial Edit Display, a list of the character string displays already existing in the current screen will be displayed.

Omron Programmable Terminal (NT20M) — 2-3-2 Direct Connection Character String Displays diagram (page 41)
Fig. 38 · 2-3-2 Direct Connection Character String Displays
2. Specify the number to be used in the table. This is not the character string table and the numbers do not correspond to item numbers in the character string table. When a number is specified, a display to set direct or indirect referencing will appear.
Page 42 of the Omron Programmable Terminal (NT20M) user manual — Character String Displays Section 2-3
Page 42 · click to enlarge
Page 42

Character String Displays Section 2-3

3. Specify “Direct.” Indirect referencing is not currently supported. The character string table will be displayed.
Omron Programmable Terminal (NT20M) — Character String Displays Section 2-3 diagram (page 42)
Fig. 39 · Character String Displays Section 2-3
4. Specify the desired table entry number. The initial value input field (contents) will be entered. The headings in the table are described in the following table.

No. Character string table entry number

IN (initialize at startup) Indicates whether or not the table value is to be initialized when the PT is turned ON.

# (quantity) Number of PC words used

Word Address of the first PC word

Comment User comment area

5. Input the desired initial string. The initial string can be omitted here if desired and input later using the table edit operation. When the initial

Heading Meaning · Contents Initial value

Page 43 of the Omron Programmable Terminal (NT20M) user manual — Character String Displays Section 2-3
Page 43 · click to enlarge
Page 43

Character String Displays Section 2-3

value field is left, the following display will appear to input the remaining settings.

Omron Programmable Terminal (NT20M) — Character String Displays Section 2-3 diagram (page 43)
Fig. 40 · Character String Displays Section 2-3
6. Make the four settings as described in the following table. The comment is optional and all four settings can be omitted here if desired and input later using the table edit operation.

Initialize (Init) Set YES to initialize the contents in the character string table when PT power is turned ON. Set to NO to maintain the previous value when PT power is turned ON.

Set words (St Word) Set the number of PC words to be used.

Word Set the address of the first PC word to be used.

Comment Input any desired user comment area

The character string display settings will appear when the above display is left.

Omron Programmable Terminal (NT20M) — Character String Displays Section 2-3 diagram (page 43)
Fig. 41 · Character String Displays Section 2-3
7. Set the way in which the display will appear on the screen. Press the Enter Key after completing all of these settings.

Heading Meaning

Page 44 of the Omron Programmable Terminal (NT20M) user manual — 2-4-1 Normal Lamps
Page 44 · click to enlarge
Page 44

Lamps Section 2-4

Number of character digits (Char; See Note)

Set the number of character digits to be displayed on the screen.

Character size (Size) Set the character size to be used for each 1-byte characters.

Scale Set the scale for characters to be displayed on the screen.

Display attributes (Attr.)

Set display attributes for the screen. Refer to page 24 for examples of how attributes are displayed on screen.

have been set will be displayed. Each normal character requires one digit and each mark requires 2 digits.

8. Set the display position. When the display position has been set, you can return to set another character string display or you can continue pressing the Escape Key to return to the Initial Edit Display.

Deleting and Modifying Direct connection character string displays are deleted or modified from the display shown in step 1. above. Select the number of the character string table and then specify DELETE or MODIFY. The modification procedure is basically the same as the creation procedure given above.

2-4 Lamps

An indicator lamp can be created by setting the lamp size, display position, and a label. You can set a maximum of 64 lamps per screen for the NT20M and 128 for the NT600M.

The procedure for creating lamps depends on whether or not direct connec- tion is ON or OFF in the Tool Settings. Both procedures are given below.

2-4-1 Normal Lamps

If you select LAMP from the Initial Edit Display, the Initial Lamp Display will appear.

Omron Programmable Terminal (NT20M) — 2-4-1 Normal Lamps diagram (page 44)
Fig. 42 · 2-4-1 Normal Lamps

Lamp Shape Either square or circular must be specified for the lamp shape.

Initial Lamp Display

Page 45 of the Omron Programmable Terminal (NT20M) user manual — Lamps Section 2-4
Page 45 · click to enlarge
Page 45

Lamps Section 2-4

Designating Area The size and display position of the lamp must be specified. The lamp area is set by designating diagonal corners (the starting and ending points) of a rect- angle for square lamps and the center and radius of circular lamps.

1, 2, 3... 1. Designate the starting point or center. 2. Designate the ending point or radius

The lamp settings are input after the lamp area has been designated.

overlapping sections may not be inverse properly. Frames on lamps and touch switches and labels may also prevent proper display for overlapping lamps/touch switches.

Omron Programmable Terminal (NT20M) — Lamps Section 2-4 diagram (page 45)
Fig. 43 · Lamps Section 2-4

Lamp number The number of the lamp being set. (The numbers, 0 to 255, are used in common with touch switches. The same number cannot be used more than once.)

Frame Whether or not lamp frames are to be displayed when lamps are displayed. If “No” is designated, lamps will be indicated by dotted lines on the Support Tool display.

Attributes Set whether the lamp will light or flash when controlled by bit signals from the host.

This attribute is effective only when controlling the lamp via bit signals from the Host Interface Units that support bit designation. This setting is ignored when controlling lamps via commands, which can be used to control the same attribute.

Label Whether or not a label is to be attached to the lamp.

Press the Enter Key after checking all of these settings. The label is input next if label input has been designated.

Show 5 more labels / short text on this page
Starting point · Radius · Center · Ending point · Lamp Settings
Page 46 of the Omron Programmable Terminal (NT20M) user manual — Lamps Section 2-4
Page 46 · click to enlarge
Page 46

Lamps Section 2-4

Inputting the Label If you set label to “Yes,” the following screen will be displayed. If you set label to “No,” you will be returned to the Initial Lamp Display.

Omron Programmable Terminal (NT20M) — Lamps Section 2-4 diagram (page 46)
Fig. 44 · Lamps Section 2-4

Input the label and press the Enter Key. You can also press the F3 Function Key to input from a list of marks that have been created. Refer to page 22 for details on the mark input procedure.

are required. 2. “@” will be input as the default label if the label setting is changed from NO to YES.

Set the size and scale of the label display.

Omron Programmable Terminal (NT20M) — Lamps Section 2-4 diagram (page 46)
Fig. 45 · Lamps Section 2-4

Position the label on the screen.

Deleting and Modifying You can delete or modify previously input lamp data on the screen. The pro- cedures for these operations are the same as those for deleting and modify- ing character strings. Refer to appropriate subsections of 2-1 Inputting Char- acter Strings for details.

Page 47 of the Omron Programmable Terminal (NT20M) user manual — Lamps Section 2-4
Page 47 · click to enlarge
Page 47

Lamps Section 2-4

2-4-2 Direct Connection Lamps

Creating Use the following procedure to create a direct connection lamp.

1, 2, 3... 1. Select LAMP from the Initial Edit Display, a list of the lamps already ex- isting in the current screen will be displayed.

Omron Programmable Terminal (NT20M) — Lamps Section 2-4 diagram (page 47)
Fig. 46 · Lamps Section 2-4
2. Specify the number to be used in the table. The numbers in this table are not the lamp numbers. When a number is specified, a display to specify either a rectangular or round lamp will appear.
Omron Programmable Terminal (NT20M) — Lamps Section 2-4 diagram (page 47)
Fig. 47 · Lamps Section 2-4
3. Specify the lamp shape. A display will appear to draw the lamp. 4. If a rectangle was specified, specify the starting and ending points (diagonally opposed corners) of the rectangle. If a circle was specify, desig-
Page 48 of the Omron Programmable Terminal (NT20M) user manual — Lamps Section 2-4
Page 48 · click to enlarge
Page 48

Lamps Section 2-4

nate the center and one point on the circumference of the circle. A dis- play will appear to specify the bit that is to control the lamp.

Omron Programmable Terminal (NT20M) — Lamps Section 2-4 diagram (page 48)
Fig. 48 · Lamps Section 2-4
5. Input the address of the PC bit that is to control the lamp. Timer/counter numbers cannot be specified. DM word address can also be specified, followed by the bit number within the word. 6. Input a comment if desired. The comment is for user use only. The lamp settings will appear when the above display is left.
Omron Programmable Terminal (NT20M) — Lamps Section 2-4 diagram (page 48)
Fig. 49 · Lamps Section 2-4
7. Set the way in which the display will appear on the screen.

Frame Whether or not lamp frames are to be displayed when lamps are displayed. If “No” is designated, lamps will be indicated by dotted lines on the Support Tool display.

Attributes Set whether the lamp will light or flash when controlled by bit signals from the host.

This attribute is effective only when controlling the lamp via bit signals from the Host Interface Units that support bit designation. This setting is ignored when controlling lamps via commands, which can be used to control the same attribute.

Label Whether or not a label is to be attached to the lamp.

Page 49 of the Omron Programmable Terminal (NT20M) user manual — Lamps Section 2-4
Page 49 · click to enlarge
Page 49

Lamps Section 2-4

Press the Enter Key after completing all of these settings. 8. If you set label to “Yes,” the following screen will be displayed. If you set label to “No,” you will be returned to the Initial Lamp Display.

Omron Programmable Terminal (NT20M) — Lamps Section 2-4 diagram (page 49)
Fig. 50 · Lamps Section 2-4

Input the label and press the Enter Key. You can also press the F3 Function Key to input from a list of marks that have been created. Refer to page 22 for details on the mark input procedure. Note 1. Labels can be only one line long. Input character strings if longer labels

are required. 2. “@” will be input as the default label if the label setting is changed from NO to YES. Set the size and scale of the label display.

Omron Programmable Terminal (NT20M) — Lamps Section 2-4 diagram (page 49)
Fig. 51 · Lamps Section 2-4

Position the label on the screen.

When lamp settings have been completed, you can return to set another lamp or you can continue pressing the Escape Key to return to the Initial Edit Display.

Deleting and Modifying Direct connection lamps are deleted or modified from the display shown in step 1. above. Select the number of the numeral table and then specify DE-

Page 50 of the Omron Programmable Terminal (NT20M) user manual — 2-5-1 Normal Touch Switches
Page 50 · click to enlarge
Page 50

Touch Switches Section 2-5

LETE or MODIFY. The modification procedure is basically the same as the creation procedure given above.

2-5 Touch Switches

A touch switch can be set by designating the size, display position, and a label. You can set a maximum of 64 touch switches per screen for the NT20M and 128 for the NT600M.

The procedure for creating touch switches depends on whether or not direct connection is ON or OFF in the Tool Settings. Both procedures are given be- low.

2-5-1 Normal Touch Switches

If you select TOUCH SW from the Initial Edit Display, the Initial Touch Switch Display will appear.

Initial Touch Switch Display

Omron Programmable Terminal (NT20M) — 2-5-1 Normal Touch Switches diagram (page 50)
Fig. 52 · 2-5-1 Normal Touch Switches

Designating Area The size and display position of the touch switch must be specified. The touch switch area is set by designating diagonal corners (the starting and ending points) of a rectangle on a grid.

1, 2, 3... 1. Designate the starting point. 2. Designate the ending point.

The touch switch settings are input after the area has been designated.

switches inverse displays may not be displayed properly.

Starting point · Ending point

Page 51 of the Omron Programmable Terminal (NT20M) user manual — Touch Switches Section 2-5
Page 51 · click to enlarge
Page 51

Touch Switches Section 2-5

Omron Programmable Terminal (NT20M) — Touch Switches Section 2-5 diagram (page 51)
Fig. 53 · Touch Switches Section 2-5

The number of the switch being set. (The numbers, 0 to 255, are used in common with lamps. The same number cannot be used more than once.)

Frame Whether or not switch frames are to be displayed when switch are displayed. If “No” is designated, the switches will be indicated by dotted lines on the Support Tool display. Either or normal or solid frame can also be designated.

Inverse Whether an inverse display will appear when the touch switch is input.

Label Whether or not a label is to be attached to the switch.

Press the Enter Key after checking all of these settings. The label is input next if label input has been designated.

Inputting the Label If you set label to “Yes,” the following display will appear. If you set label to “No,” you will be returned to the Initial Touch Switch Display.

Omron Programmable Terminal (NT20M) — Touch Switches Section 2-5 diagram (page 51)
Fig. 54 · Touch Switches Section 2-5

Input the label and press the Enter Key. You can also press the F3 Function Key to input from a list of marks that have been created. Refer to page 22 for details on the mark input procedure.

Touch Switch Settings · Switch number

Page 52 of the Omron Programmable Terminal (NT20M) user manual — 2-5-2 Direct Connection Touch Switches
Page 52 · click to enlarge
Page 52

Touch Switches Section 2-5

are required. 2. “@” will be input as the default label if the label setting is changed from NO to YES. Set the size and scale of the label display.

Omron Programmable Terminal (NT20M) — Touch Switches Section 2-5 diagram (page 52)
Fig. 55 · Touch Switches Section 2-5

Position the label on the screen.

Deleting and Modifying You can delete or modify previously input touch switch data on the screen. The procedures for these operations are the same as those for deleting and modifying character strings. Refer to appropriate subsections of 2-1 Inputting Character Strings for details.

default.

2-5-2 Direct Connection Touch Switches

Creating Use the following procedure to create a direct connection touch switch.

1, 2, 3... 1. Select TOUCH SW from the Initial Edit Display, a list of the touch switches already existing in the current screen will be displayed.

Omron Programmable Terminal (NT20M) — 2-5-2 Direct Connection Touch Switches diagram (page 52)
Fig. 56 · 2-5-2 Direct Connection Touch Switches
Page 53 of the Omron Programmable Terminal (NT20M) user manual — Touch Switches Section 2-5
Page 53 · click to enlarge
Page 53

Touch Switches Section 2-5

2. Specify the number to be used in the table. The numbers in this table are not the touch switch numbers. A display will appear to draw the touch switch. 3. Specify the starting and ending points (diagonally opposed corners) of the rectangle. A display will appear to specify the bit that is to control the touch switch.
Omron Programmable Terminal (NT20M) — Touch Switches Section 2-5 diagram (page 53)
Fig. 57 · Touch Switches Section 2-5

4. Input the address of the PC bit that is to control the touch switch. Timer/ counter numbers cannot be specified. DM word address can also be specified, followed by the bit number within the word. 5. Input a comment if desired. The comment is for user use only. 6. Specify the function of the touch switch. The display that appears next will depend on the setting made here. The three possible settings are as follows: Notify : Sends a signal to the PC when the switch is pressed, i.e., turns the specified bit ON while the switch is pressed. SwScreen: Switches to a specified screen when the switch is pressed.

This setting is used for stand-alone operation. Keypad: Creates a key for numeral editing. 7. Notify: Specify the address of the PC bit to be controlled by the touch switch. Timer/counter numbers cannot be specified. A DM word address can be specified followed by the bit number. A user comment can also be input if desired. SwScreen: Specify the number of the screen to be switched to when the touch switch is pressed. The screen number set here will be set in the PT status notify area in the direct connection information. Keypad: Specify the touch switch number to be used for numeral edit- ing.

touch switch status, the status of the specified bit will vary with the status of the touch switch, but all other bits in the specified word will be turned OFF. Timing must be precisely controlled if more than one bit in the same DM word is used for notification to ensure accuracy in reading the status.

Page 54 of the Omron Programmable Terminal (NT20M) user manual — Touch Switches Section 2-5
Page 54 · click to enlarge
Page 54

Touch Switches Section 2-5

The touch switch settings will appear when the above setting has been made.

Omron Programmable Terminal (NT20M) — Touch Switches Section 2-5 diagram (page 54)
Fig. 58 · Touch Switches Section 2-5
8. Set the way in which the display will appear on the screen.

Frame Whether or not a switch frame is to be displayed when the switch is displayed. If “No” is designated, the switch will be indicated by dotted lines on the Support Tool display. Either or normal or solid frame can also be designated.

Inverse Whether an inverse display will appear when the touch switch is input.

Attributes Specify whether the switch is to light of flash while pressed.

Label Whether or not a label is to be attached to the switch.

Press the Enter Key after completing all of these settings. 9. If you set label to “Yes,” the following screen will be displayed. If you set label to “No,” you will be returned to the Initial Touch Switch Display.

Omron Programmable Terminal (NT20M) — Touch Switches Section 2-5 diagram (page 54)
Fig. 59 · Touch Switches Section 2-5

Input the label and press the Enter Key. You can also press the F3 Function Key to input from a list of marks that have been created. Refer to page 22 for details on the mark input procedure.

Page 55 of the Omron Programmable Terminal (NT20M) user manual — 2-6 Bar Graphs
Page 55 · click to enlarge
Page 55

Bar Graphs Section 2-6

are required.

2. “@” will be input as the default label if the label setting is changed from NO to YES.

Set the size and scale of the label display.

Omron Programmable Terminal (NT20M) — Bar Graphs Section 2-6 diagram (page 55)
Fig. 60 · Bar Graphs Section 2-6

Position the label on the screen.

When touch switch settings have been completed, you can return to set another touch switch or you can continue pressing the Escape Key to return to the Initial Edit Display.

Deleting and Modifying Direct connection touch switches are deleted or modified from the display shown in step 1. above. Select the number of the numeral table and then specify DELETE or MODIFY. The modification procedure is basically the same as the creation procedure given above.

2-6 Bar Graphs

Values from numeral tables can be used to create bar graphs by setting the numeral table entries to be referenced, the display positions, the display style, and the display direction. Bars can also be displayed in the negative direction and the display direction can be reversed.

You can set a maximum of 8 bars per screen for the NT20M and 50 for the NT600M.

The procedure for setting bar graphs depends on whether or not direct con- nection is ON or OFF in the Tool Settings. Both procedures are given below.

Page 56 of the Omron Programmable Terminal (NT20M) user manual — Bar Graphs Section 2-6
Page 56 · click to enlarge
Page 56

Bar Graphs Section 2-6

2-6-1 Creating Normal Bar Graphs

If you select BAR GRPH from the Initial Edit Display, the Initial Bar Graph Display will appear.

Initial Bar Graph Display

Omron Programmable Terminal (NT20M) — Bar Graphs Section 2-6 diagram (page 56)
Fig. 61 · Bar Graphs Section 2-6

A bar graph is set by designating both ends (the starting and ending points) of a diagonal line across the bar graph. It makes no difference whether the display position of a bar graph is designated from the right or left, or from the top or bottom. The ending point designates only the length (along the X axis) of the bar graph. Whether the bar is vertical or horizontal is designated next in the display settings.

2 bits or 255 dots (set with display setting) BAR GRAPH

1, 2, 3... 1. Designate the starting point. 2. Designate the ending point.

Designating Display Position · Starting point · Ending point

Page 57 of the Omron Programmable Terminal (NT20M) user manual — Bar Graphs Section 2-6
Page 57 · click to enlarge
Page 57

Bar Graphs Section 2-6

Setting the Numeral Table Reference

Specify the entry number of the numeral table to be referenced for the bar graph.

Omron Programmable Terminal (NT20M) — Bar Graphs Section 2-6 diagram (page 57)
Fig. 62 · Bar Graphs Section 2-6

Inputting Initial Value Set the initial value and then press the Enter Key.

Omron Programmable Terminal (NT20M) — Bar Graphs Section 2-6 diagram (page 57)
Fig. 63 · Bar Graphs Section 2-6
Page 58 of the Omron Programmable Terminal (NT20M) user manual — Bar Graphs Section 2-6
Page 58 · click to enlarge
Page 58

Bar Graphs Section 2-6

Display Settings Set all the bar graph display attributes and press the Enter Key.

Omron Programmable Terminal (NT20M) — Bar Graphs Section 2-6 diagram (page 58)
Fig. 64 · Bar Graphs Section 2-6

Direction Whether the bar is to be displayed in the normal direction or the reverse direction. (See note 1.)

Width The width of the bar graph. The width must be 3 dots or greater to set a frame. The width must be 8 dots or greater when displaying horizontal bars from the top of the screen or when displaying vertical bars from the right of the screen.

Graph Frame Whether or not a graph frame showing 100% is to be displayed.

Disp sign Whether or not a negative (–) sign is to be displayed. If a negative sign is used, the bar graph can be displayed in the reverse direction for negative values. (See note 2.)

100% value The value of the denominator for percentage calculations. You cannot set numerals of 0 or less as the 100% value.

Display % Whether or not the result of percentage calculations is to be displayed as numerals.

Size of % Set the character size of numerals for when percentages are displayed.

Scale Set the scale factor for the percentage display. The NT600M can be set to 64X in addition to those shown above.

bar graphs can be displayed top to bottom or bottom to top. 2. If a display sign (negative value) is specified, the center of the bar will be set as 0% and the right or top of the bar will be set as 100% (for normal displays). (The center will be one dot up or to the left of center for odd- sized bars.) Examples are shown below.

Show 5 more labels / short text on this page
Displaying 60% · Without sign · 60% · With sign · 60%
Page 59 of the Omron Programmable Terminal (NT20M) user manual — 2-6-2 Direct Connection Bar Graphs
Page 59 · click to enlarge
Page 59

Bar Graphs Section 2-6

3. The following relationship exists between the number of display dots on the screen, the content of the numeral table reference, and the 100% value.

(Number of display dots) = (Maximum length of graph) x

If the results for a bar graph display is over 100%, a 1-dot blank will be displayed past the size set with the Support Tool and an 8-dot bar will be display beyond the blank to indicate a value over 100% (see below).

1 dot 8 dots

Setting % Display Position If the % Display is set to “Yes,” then the display position is designated. If it is set to “No,” then this screen is not displayed.

Designate the display position of the percentage value.

Deleting and Modifying You can delete or modify previously input bar graph data on the screen. The procedures for these operations are the same as those for deleting and mo- difying character strings. Refer to appropriate subsections of 2-1 Inputting Character Strings for details.

2-6-2 Direct Connection Bar Graphs

Creating Use the following procedure to create a direct connection bar graph.

1, 2, 3... 1. Select BAR GRPH from the Initial Edit Display, a list of the bar graphs already existing in the current screen will be displayed.

Omron Programmable Terminal (NT20M) — 2-6-2 Direct Connection Bar Graphs diagram (page 59)
Fig. 65 · 2-6-2 Direct Connection Bar Graphs

The headings in this list are as follows: No.: The number of the bar graph in the current display.

Show 7 more labels / short text on this page
Displaying –60% · Without sign · 0% · With sign · –60% · (Referenced numeral table) · (100% data value)
Page 60 of the Omron Programmable Terminal (NT20M) user manual — Bar Graphs Section 2-6
Page 60 · click to enlarge
Page 60

Bar Graphs Section 2-6

This is not the numeral table entry number. M Tbl: The numeral table entry number being used. Rf: The access method for the numeral table (direct or indirect) Dr: The direction of the bar. %: Whether or not the percentage display is being used. 2. Specify the number to be used in the table. This is not the numeral table and the numbers do not correspond to item numbers in the numeral table. When the number is specified, a cursor will appear to designate the starting and ending points of the bar. 3. Designate the starting and ending points of a diagonal line across the bar graph. It makes no difference whether the display position of a bar graph is designated from the right or left, or from the top or bottom. The ending point designates only the length (along the X axis) of the bar graph. Whether the bar is vertical or horizontal is designated later in the display settings. When the length is designated, a display to set direct or indirect referencing will appear. 4. Specify “Direct.” Indirect referencing is not currently supported. The nu- meral table will be displayed.

5. Specify the desired table entry number. The initial value input field (contents) will be entered. The headings in the table are described in the following table.

No. Numeral table entry number

IN (initialize at startup) Indicates whether or not the table value is to be initialized when the PT is turned ON.

# (quantity) Number of PC words used

Word Address of the first PC word

Comment User comment area

6. Input the desired initial value. This value can be omitted here if desired and input later using the table edit operation. The initial value can be up to 8 digits long. When the initial value field is left, the following display will appear to input the remaining settings.

Heading Meaning · Contents Initial value

Page 61 of the Omron Programmable Terminal (NT20M) user manual — Bar Graphs Section 2-6
Page 61 · click to enlarge
Page 61

Bar Graphs Section 2-6

Refer to page 61 for details.

7. Make the four settings as described in the following table. The comment is optional and all four settings can be omitted here if desired and input later using the table edit operation.

Initialize (Init) Set YES to initialize the contents in the numeral table when PT power is turned ON. Set to NO to maintain the previous value when PT power is turned ON.

Set words (St Word) Set the number of PC words to be used.

Word Set the address of the first PC word to be used.

Comment Input any desired user comment area

The bar graph display settings will appear when the above display is left.

Omron Programmable Terminal (NT20M) — Bar Graphs Section 2-6 diagram (page 61)
Fig. 66 · Bar Graphs Section 2-6
8. Set the way in which the display will appear on the screen.

Heading Meaning

Page 62 of the Omron Programmable Terminal (NT20M) user manual — Bar Graphs Section 2-6
Page 62 · click to enlarge
Page 62

Bar Graphs Section 2-6

Direction Whether the bar is to be displayed in the normal direction or the reverse direction. (See note 1.)

Width The width of the bar graph. The width must be 3 dots or greater to set a frame. The width must be 8 dots or greater when displaying horizontal bars from the top of the screen or when displaying vertical bars from the right of the screen.

Graph Frame Whether or not a graph frame showing 100% is to be displayed.

Disp sign Whether or not a negative (–) sign is to be displayed. If a negative sign is used, the bar graph can be displayed in the reverse direction for negative values. (See note 2.)

100% value The value of the denominator for percentage calculations. You cannot set numerals of 0 or less as the 100% value.

Display % Whether or not the result of percentage calculations is to be displayed as numerals.

Size of % Set the character size of numerals for when percentages are displayed.

Scale Set the scale factor for the percentage display. The NT600M can be set to 64X in addition to those shown above.

bar graphs can be displayed top to bottom or bottom to top. 2. If a display sign (negative value) is specified, the center of the bar will be set as 0% and the right or top of the bar will be set as 100% (for normal displays). (The center will be one dot up or to the left of center for odd- sized bars.) Examples are shown below.

3. The following relationship exists between the number of display dots on the screen, the content of the numeral table reference, and the 100% value.

(Number of display dots) = (Maximum length of graph) x

If the results for a bar graph display is over 100%, a 1-dot blank will be displayed past the size set with the Support Tool and an 8-dot bar will be display beyond the blank to indicate a value over 100% (see below).

1 dot 8 dots

Press the Enter Key after completing all of these settings.

When the display position has been set, you can return to set another bar graph or you can continue pressing the Escape Key to return to the Initial Edit Display.

Show 12 more labels / short text on this page
Displaying 60% · Without sign · 60% · With sign · 60% · Displaying –60% · Without sign · 0% · With sign · –60% · (Referenced numeral table) · (100% data value)
Page 63 of the Omron Programmable Terminal (NT20M) user manual — 2-7-1 Normal Operation
Page 63 · click to enlarge
Page 63

Editing Memory Tables Section 2-7

Deleting and Modifying Direct connection bar graphs are deleted or modified from the display shown in step 1. above. Select the number of the numeral table and then specify DELETE or MODIFY. The modification procedure is basically the same as the creation procedure given above.

2-7 Editing Memory Tables

Memory tables can be displayed for editing or to create lists of screen num- bers referencing a specified table entry. This function is the same when NEXT, F2 (TBL EDIT) is executed from the Screen Selection Display.

The procedure for editing memory tables depends on whether or not direct connection is ON or OFF in the Tool Settings. Both procedures are given be- low.

2-7-1 Normal Operation

If you select TBL EDIT on the Initial Edit Display, the Initial Table Editing Dis- play will appear.

Initial Table Edit Display

Omron Programmable Terminal (NT20M) — 2-7-1 Normal Operation diagram (page 63)
Fig. 67 · 2-7-1 Normal Operation

Selecting the Memory Table Select either numeral table or string table for editing.

Editing the numeral table and string table is explained separately below.

Editing Numeral Tables If you select the numeral table to edit, the following display will appear. For the NT20M, numeral table entries are numbered from 0 to 127, for a total of 128. For the NT600M, numeral table entries are numbered from 0 to 255, for a total of 256. At first, only the contents of table entries 0 to 63 are displayed

Page 64 of the Omron Programmable Terminal (NT20M) user manual — Editing Memory Tables Section 2-7
Page 64 · click to enlarge
Page 64

Editing Memory Tables Section 2-7

on the screen. To display entries 64 and up, press the Pg Dn Key; and to re- turn to previously displayed entries, press the Pg Up Key.

Omron Programmable Terminal (NT20M) — Editing Memory Tables Section 2-7 diagram (page 64)
Fig. 68 · Editing Memory Tables Section 2-7

table entry indicated by the cursor will appear. 1, 2, 3... 1. With the cursor, select the numeral table entry that you want to edit, and press the Enter Key. 2. Input the new value and press the Enter Key. 3. When you are finished editing, press the Escape Key. When the Escape Key is pressed, you will be returned to the Memory Table Selection Display.

Editing String Tables If you select character strings to edit, the following display will appear. For the NT20M, string table entries are numbered from 0 to 31, for a total of 32. For the NT600M, string table entries are numbered from 0 to 255, for a total of 256. Only 32 entries are displayed on each page. Use the Pg Up and Pd Dn Keys to scroll to other pages.

Omron Programmable Terminal (NT20M) — Editing Memory Tables Section 2-7 diagram (page 64)
Fig. 69 · Editing Memory Tables Section 2-7

table entry indicated by the cursor will appear.

Page 65 of the Omron Programmable Terminal (NT20M) user manual — 2-7-2 Direct Connection Operation
Page 65 · click to enlarge
Page 65

Editing Memory Tables Section 2-7

1, 2, 3... 1. With the cursor, select the string table entry that you want to edit, and press the Enter Key. 2. Input the character string and press the Enter Key. 3. When you are finished editing, press the Escape Key.

List of Referencing Screens You can display a list of screens referencing designated number or string table entries by pressing F1 when the numeral or string table is displayed.

With the cursor, select the memory table entry that you want to list references for, and press F1 (Reference). The table below is an example of a memory table reference display. The displayed numbers indicate the screens that ref- erence the designated table entry.

Omron Programmable Terminal (NT20M) — Editing Memory Tables Section 2-7 diagram (page 65)
Fig. 70 · Editing Memory Tables Section 2-7

2-7-2 Direct Connection Operation

If you select TBL EDIT on the Initial Edit Display, the Initial Table Editing Dis- play will appear.

Selecting the Memory Table Select either numeral table or string table for editing.

Editing the numeral table and string table is explained separately below.

Editing Numeral Tables If the numeral table is specified, the numeral table will appear in the same form as used for numeral editing or bar graphs.

1, 2, 3... 1. Specify the numeral table entry that you want to edit. 2. Input the initial value as desired and continue making or changing set- tings in the same fashion as originally done when creating numeral edit- ing areas or bar graphs. 3. You can continue inputting or changing setting for other numeral table entires when finished with the first one. 4. When you are finished editing, press the Escape Key. When the Escape Key is pressed, you will be returned to the Memory Table Selection Display.

Editing String Tables If the string table is specified, the string table will appear in the same form as used for character string display.

1, 2, 3... 1. Specify the string table entry that you want to edit. 2. Input the initial value as desired and continue making or changing set- tings in the same fashion as originally done when creating string dis- plays.

Page 66 of the Omron Programmable Terminal (NT20M) user manual — 2-8 Numeral Editing
Page 66 · click to enlarge
Page 66

Numeral Editing Section 2-8

3. You can continue inputting or changing setting for other string table entires when finished with the first one. 4. When you are finished editing, press the Escape Key.

Words and Numeric Data When setting word addresses for numeral or string tables, the number of PC words to be used and the address of the first word are input. For example, for numeral table entires, one word can be specified to use from 1 to 4 digits and two words can be specified to used from 5 to 8 digits. If two words are speci- fied and DM 0100 is specified as the first word, the following PC data will be used.

DM 0101 DM 0100

0 0 1 2 3 4 5 6

Specified word Next higher word

Set the leftmost digit to F to specify negative values. The example on the left in the following diagram shows the setting for –12345; the example on the right, for –123.

DM 0101 DM 0100

DM 0100

F 0 0 1 2 3 4 5

F 1 2 3

Specified word Next higher word

storage format for PC memory when direct connection is being used. This format, however, differs form that used when direct connection is not being used.

2-8 Numeral Editing

Screens can be create that allow numeric inputs from the PT to the host. These screens are called numeral editing screens. Input values are desig- nated on-screen via function keys or touch switches or from Expansion I/O Units (32/64 Terminals or 12-key Function Key Units). The number of digits that can be input and the number of digits transmitted to the host can be set. Also, the Keypad setting in the screen attributes can be set to “user” to en- able flexible layout of input keys

A maximum of 50 numeral edit settings can be made per screen.

The procedure for creating numeral editing areas depends on whether or not direct connection is ON or OFF in the Tool Settings. Both procedures are giv- en below.

screens. 2. Numeral editing cannot be used if bit input is enabled in the display attrib- utes for PT with function keys or without touch switches.

Show 4 more labels / short text on this page
Registered words · Specified word · Registered words · Registered word
Page 67 of the Omron Programmable Terminal (NT20M) user manual — Numeral Editing Section 2-8
Page 67 · click to enlarge
Page 67

Numeral Editing Section 2-8

3. The Numeral Editing function uses the lower portion of the display. When numeral editing is set on a screen where characters and numerals are displayed, the characters and/or numerals may be hidden. 2-8-1 Normal Numeral Editing

If you select NUM EDIT from the Initial Edit Display, the following display will appear.

Initial Numeral Editing Display

Omron Programmable Terminal (NT20M) — Numeral Editing Section 2-8 diagram (page 67)
Fig. 71 · Numeral Editing Section 2-8

The headings have the following meanings:

No.: The order that has been set for numeral editing. M Tbl: The number of the numeral table entry which is used. Snd: Number of transmission digits. Inp: Number of input digits. Dsp: Numeral display (Yes/No)

The blank right-hand column is used when reordering number editing areas.

Select the numeral table entry that will be input on-screen.

Inputting Initial Value Input the initial value (contents) for the selected numeral table entry.

Omron Programmable Terminal (NT20M) — Numeral Editing Section 2-8 diagram (page 67)
Fig. 72 · Numeral Editing Section 2-8

Numeral Table Entry

Page 68 of the Omron Programmable Terminal (NT20M) user manual — Numeral Editing Section 2-8
Page 68 · click to enlarge
Page 68

Numeral Editing Section 2-8

When the initial value is designated, the number of digits input and the num- ber of digits transmitted to the host are set.

Input and Transmission Digits

Omron Programmable Terminal (NT20M) — Numeral Editing Section 2-8 diagram (page 68)
Fig. 73 · Numeral Editing Section 2-8

Input digits (Input Col)

Set the number of digits that can be input via touch switches or function keys. You can set from 1 to 8 digits.

Set the number of digits that are transmitted to the host. You can select either 4 or 8 digits.

Numeral Display (Num Disp)

Select whether or not numeral display is to be set at the same time as numeral editing.

Press the Enter Key after making all the settings.

If Numeral Display is set to “Yes,” the Numeral Display Settings Display will be displayed automatically. Set the numeral display as required.

Omron Programmable Terminal (NT20M) — Numeral Editing Section 2-8 diagram (page 68)
Fig. 74 · Numeral Editing Section 2-8

If Numeral Display is set to “No,” you will be returned to the selection of the memory table for writing.

Transmission Digits (Sending)

Page 69 of the Omron Programmable Terminal (NT20M) user manual — Numeral Editing Section 2-8
Page 69 · click to enlarge
Page 69

Numeral Editing Section 2-8

Deleting Numeral Editing You can delete numeral edit settings that have already been made.

1, 2, 3... 1. To delete a numeral editing setting, move the bar cursor to the setting you want to delete on the Initial Display for Numeral Editing and then press the Enter Key.

Omron Programmable Terminal (NT20M) — Numeral Editing Section 2-8 diagram (page 69)
Fig. 75 · Numeral Editing Section 2-8
2. Press F1 (Delete). A confirmation prompt will be displayed on the screen. Note 1. If a numeral display is set for the selected numeral edit settings, then

those settings will be shown in a guide box. 2. The switch display at the bottom of the screen will disappear if all numeral editing settings are deleted.

You can modify a numeral edit settings that has already been made.

1, 2, 3... 1. Move the bar cursor to the numeral edit setting you want to modify, and press the Enter Key. The contents of the numeral editing setting that you select will be displayed on the screen.

2. Modify the numeral edit settings as desired and press the Enter Key.

settings will be shown in a guide box.

Modifying Numeral Editing

Page 70 of the Omron Programmable Terminal (NT20M) user manual — Numeral Editing Section 2-8
Page 70 · click to enlarge
Page 70

Numeral Editing Section 2-8

Changing the Order of Numeral Editing

You can change the order of numeral edit settings that have already been made.

1, 2, 3... 1. Press F2 (Change Order). A list of numeral edit settings will be dis- played on the screen.

Omron Programmable Terminal (NT20M) — Numeral Editing Section 2-8 diagram (page 70)
Fig. 76 · Numeral Editing Section 2-8
2. Move the bar cursor to the numeral edit setting for which you want to change the order, and press the Space Key. The new order will be displayed in the order column. 3. To change the set order, press the Enter Key, or to cancel the operation without changing the order, press the Escape Key.

settings will be shown in a guide box.

Input Key Layout Numeral input keys can be placed as desired on the PT screen if the Keypad setting in the screen attributes is set to “user.” The layout operation is per- formed starting from the Screen Selection Display.

ridden by those of the parent screen, i.e., parent screen attributes take prior- ity.

Use the following procedure to create and layout keys for numeral input.

1, 2, 3... 1. Set the “Keypad” screen attribute to “User.” Refer to page 78 for the set- ting procedure. The default attribute is “System,” and will have to be changed. If this attribute is set to “System” the input keys for numeral editing will appear in their normal fixed positions when the F4 Key is pressed in the next step. 2. Create and place the input keys as desired using either the touch switch function described on page 46 or press the F4 Key from the Numeral Editing Display and use the edit function described on page 87.

Key allocations depend on the model of PT being used. Included are the al- locations for function keys.

Page 71 of the Omron Programmable Terminal (NT20M) user manual — Numeral Editing Section 2-8
Page 71 · click to enlarge
Page 71

Numeral Editing Section 2-8

Touch Panel PTs (DT___)

Omron Programmable Terminal (NT20M) — Numeral Editing Section 2-8 diagram (page 71)
Fig. 77 · Numeral Editing Section 2-8

through F cannot be used for the keypad even if they are set.

Function Key PTs (DF___)

Omron Programmable Terminal (NT20M) — Numeral Editing Section 2-8 diagram (page 71)
Fig. 78 · Numeral Editing Section 2-8

F1 (1) 0 F5 (5) 4 F9 (9) 8

F2 (2) 1 F6 (6) 5 F10 (0) 9

F3 (3) 2 F7 (7) 6 F11 (CLR) 10

F4 (4) 3 F8 (8) 7 F12 (+/–) 11

PTs without Touch Panels (DN___)

Omron Programmable Terminal (NT20M) — Numeral Editing Section 2-8 diagram (page 71)
Fig. 79 · Numeral Editing Section 2-8

F1 (1) 0 F10 (5) 9 F23 (.) 22

F2 (2) 1 F11 (5) 10 F24 (HOME) 23

F3 (3) 2 F12 (6) 11 F25 () 24

F4 (4) 3 F17 (7) 16 F26 () 25

F5 (5) 4 F18 (7) 17 F27 () 26

F6 (6) 5 F19 (8) 18 F28 () 27

F7 (7) 6 F20 (6) 19 F29 (ENTER) 28

12-key Function Key Units

Omron Programmable Terminal (NT20M) — Numeral Editing Section 2-8 diagram (page 71)
Fig. 80 · Numeral Editing Section 2-8

F1 (1) 0 F5 (5) 4 F9 (9) 8

F2 (2) 1 F6 (6) 5 F10 (0) 9

F3 (3) 2 F7 (7) 6 F11 (CLR) 10

F4 (4) 3 F8 (8) 7 F12 (+/–) 11

32/16 Terminals

Page 72 of the Omron Programmable Terminal (NT20M) user manual — 2-8-2 Direct Connection Numeral Editing
Page 72 · click to enlarge
Page 72

Numeral Editing Section 2-8

Numeral editing is not possible for PTs without Touch Panels is Expansion I/O Units with 10/02 Terminals are used.

2-8-2 Direct Connection Numeral Editing

Creating Use the following procedure to create a direct connection numeral editing area.

1, 2, 3... 1. Select NUM EDIT from the Initial Edit Display, a list of the numeral edit- ing already existing in the current screen will be displayed.

Omron Programmable Terminal (NT20M) — 2-8-2 Direct Connection Numeral Editing diagram (page 72)
Fig. 81 · 2-8-2 Direct Connection Numeral Editing
2. Specify the number to be used in the table. This is not the numeral table and the numbers do not correspond to item numbers in the numeral table. When a number is specified, the numeral table will be displayed.
3. Specify the desired table entry number. The initial value input field (contents) will be entered. The headings in the table are described in the following table.
Page 73 of the Omron Programmable Terminal (NT20M) user manual — Numeral Editing Section 2-8
Page 73 · click to enlarge
Page 73

Numeral Editing Section 2-8

No. Numeral table entry number

IN (initialize at startup) Indicates whether or not the table value is to be initialized when the PT is turned ON.

# (quantity) Number of PC words used

Word Address of the first PC word

Comment User comment area

4. Input the desired initial value. This value can be omitted here if desired and input later using the table edit operation. The initial value can be up to 8 digits long. When the initial value field is left, the following display will appear to input the remaining settings.

Refer to page 61 for details.

5. Make the four settings as described in the following table. The comment is optional and all four settings can be omitted here if desired and input later using the table edit operation.

Initialize (Init) Set YES to initialize the contents in the numeral table when PT power is turned ON. Set to NO to maintain the previous value when PT power is turned ON.

Set words (St Word) Set the number of PC words to be used.

Word Set the address of the first PC word to be used.

Comment Input any desired user comment area

Heading Meaning · Contents Initial value · Heading Meaning

Page 74 of the Omron Programmable Terminal (NT20M) user manual — 2-8-3 Precautions for Numeral Editing
Page 74 · click to enlarge
Page 74

Numeral Editing Section 2-8

The numeral editing settings will appear when the above display is left.

Omron Programmable Terminal (NT20M) — Numeral Editing Section 2-8 diagram (page 74)
Fig. 82 · Numeral Editing Section 2-8
6. Set the way in which the display will appear on the screen. Refer to the examples on page 30.

Number of integer digits (Integer)

Set the number of digits for the integer portion of the number.

Number of decimal digits (Decimal)

Set the number of digits for the decimal portion of the number.

Zero suppress (Zero Sup)

Set whether or not leading zeros are to be displayed on the screen.

Display sign (Disp Sign)

Set whether or not negative signs are to be displayed on the screen. The positive sign is not displayed.

Character size (Char Size)

Set the size of characters to be displayed on the screen.

Scale Set the scale factor for the display. The NT600M can be set to 64X in addition to those shown above.

Attributes Sets display attributes for the screen. Refer to page 24 for examples of how attributes are displayed on screen.

Press the Enter Key after completing all of these settings. 7. Set the display position. When the display position has been set, you can return to set another numeral editing area or you can continue pressing the Escape Key to return to the Initial Edit Display.

Deleting and Modifying Direct connection numeral editing is deleted or modified from the display shown in step 1. above. Select the number of the numeral table and then specify DELETE or MODIFY. The modification procedure is basically the same as the creation procedure given above.

Input Key Layout If the Keypad setting in the screen attributes is set to “user,” input keys can be created and positioned the same as they can for normal numeral editing. Refer to page 66 for details.

2-8-3 Precautions for Numeral Editing

The following limitation exist when creating numeral editing screens depend- ing on the model of the PT.

Page 75 of the Omron Programmable Terminal (NT20M) user manual — 2-9-1 Creating New Polylines
Page 75 · click to enlarge
Page 75

Polylines Section 2-9

PT Bit input disabled Bit input enabled

DF___ or DN___ with 12-key Function Key Unit

F1 through F12 can be used. Numeral editing is not possible.

DN___ with 32/16 Terminal F1 through F12 and F17 through F29 can be used. F13 through F16 are used as system keys.

Numeral editing is not possible. F13 through F16 are used as system keys.

DT___ Touch switches 231 through 255 can be used for numeral editing input keys.

Touch switches 231 through 255 can be used for numeral editing input keys or for normal touch switches.

2-9 Polylines

Polylines (a broken line made up of one or more line segments) can be created on the screen. You can make a polyline by connecting a maximum of 255 line segments. The amount of polyline data for a screen depends only on the amount of memory remaining. Select GRAPHIC from the Initial Edit Dis- play to access the Graphic Input Display and then select POLYLINE. The Initial Polyline Display will appear.

Omron Programmable Terminal (NT20M) — 2-9 Polylines diagram (page 75)
Fig. 83 · 2-9 Polylines

2-9-1 Creating New Polylines

1, 2, 3... 1. Specify CREATE. 2. Designate the starting point of the polyline by positioning the cursor and pressing the Enter Key. 3. Designate the mid-points (the points between the starting point and the ending point) for the polyline in the same fashion. To return to the previously designated point, press the Escape Key. To stop the process and return to the Initial Edit Display, press the Es- cape Key.

Initial Polyline Display

Page 76 of the Omron Programmable Terminal (NT20M) user manual — 2-9-3 Modifying Polylines
Page 76 · click to enlarge
Page 76

Polylines Section 2-9

4. Designate the ending point for the polyline. 5. Press the Shift and Enter Keys or double-click the left mouse button to indicate that the ending point has been entered.

2-9-2 Deleting Polylines

You can delete polylines set on the screen.

1, 2, 3... 1. Specify DELETE. The starting points for all of the polylines on the screen will be indicated by small squares.

2. To delete a polyline, specify the starting point for that line. The starting point, ending point, and all of the mid-points for the designated polyline will be indicated by small squares, and a message will be displayed asking whether you actually want to delete the line. If points overlap, some squares may not be displayed.
3. If you do want to delete the polyline, then press the Enter Key, or to cancel and return to step 1, press the Escape Key.

2-9-3 Modifying Polylines

You can modify polylines set on the screen.

1, 2, 3... 1. Select MODIFY. The starting points for all of the polylines on the screen will be indicated by small squares.

2. To modify a polyline, specify the starting point for that line.
Page 77 of the Omron Programmable Terminal (NT20M) user manual — 2-10-1 Creating New Circles
Page 77 · click to enlarge
Page 77

Circles Section 2-10

3. You can move the cross-shaped cursor to the starting point of the designated polyline and then make additions or modifications in the same way as when creating new polylines.

2-10 Circles

Circles can be created on the screen. The amount of circle data for a screen depends only on the amount of memory remaining. Select GRAPHIC from the Initial Edit Display to access the Graphic Input Display and then select CIRCLE. The Initial Circle Display will appear.

Omron Programmable Terminal (NT20M) — 2-10 Circles diagram (page 77)
Fig. 84 · 2-10 Circles

2-10-1 Creating New Circles

1, 2, 3... 1. Specify CREATE. 2. Designate the center of the circle. The center of the circle will be indi- cated by an x.

3. Designate the radius and press the Enter Key. The entire circle must be contained within the display area both when creating it and when displaying it on the PT screen. To return to step 1, press the Escape Key.

Initial Circle Display

Page 78 of the Omron Programmable Terminal (NT20M) user manual — 2-10-3 Modifying Circles
Page 78 · click to enlarge
Page 78

Circles Section 2-10

2-10-2 Deleting Circles

You can delete circles set on the screen.

1, 2, 3... 1. Specify DELETE. The center points for all of the circles on the screen will be indicated by small squares.

2. Specify the circle you want to delete. The designated circle will be enclosed by a square frame and a message will be displayed asking whether you actually want to delete the circle.
3. To delete the circle, press the Enter Key, or to cancel the deletion and return to step 1, press the Escape Key.

2-10-3 Modifying Circles

1, 2, 3... 1. Specify MODIFY. The center points for all of the circles on the screen are indicated by small squares.

2. Specify the center of the circle you want to modify.
Page 79 of the Omron Programmable Terminal (NT20M) user manual — 2-11 Continuous and Overlapping Screens
Page 79 · click to enlarge
Page 79

Continuous and Overlapping Screens Section 2-11

3. You can move the cross-shaped cursor to the perimeter of the designated circle and then modify the radius and center point in the same way as when creating new circles.

2-11 Continuous and Overlapping Screens

You can combine previously created multiple screens into a continuous screens by linking them or into one screen by stacking them into overlapping screens. To make continuous screens, first one screen is designated as the parent screen, and then child screens and the screen scrolling unit are set for the parent screen. To make overlapping screens, first one screen is desig- nated as the parent screen, and then child screens are designated for the parent screen.

Setting the Parent Screen On the Screen Selection Display, move the bar cursor to a screen number for which no data is entered, and press F8 (continuous/overlapping screens).

Omron Programmable Terminal (NT20M) — 2-11 Continuous and Overlapping Screens diagram (page 79)
Fig. 85 · 2-11 Continuous and Overlapping Screens

If you designate a screen for which data is already registered, a message will appear asking whether you want to delete that data. If you do want to delete it, then press the Enter Key.

To return to the Screen Selection Display, press the Escape Key.

If the designated screen is already a parent screen, its contents (the child screens) can be edited.

Selecting Continuous or Overlapping

Specify whether the designated parent screen is to be used for continuous or overlapping screens.

Continuous and overlapping screens are explained separately below.

screen data could not be created. If that happens, press any key and then again select the child screens again.

Page 80 of the Omron Programmable Terminal (NT20M) user manual — Continuous and Overlapping Screens Section 2-11
Page 80 · click to enlarge
Page 80

Continuous and Overlapping Screens Section 2-11

  • The child screen has been designated for another parent screen.
  • No more than one child screen has been designated.

Continuous Screens The screen numbers of the child screens you want to display continuously are registered next. Register the child screen numbers in the order that you want them displayed. You can register a maximum of 8 child screens.

Omron Programmable Terminal (NT20M) — Continuous and Overlapping Screens Section 2-11 diagram (page 80)
Fig. 86 · Continuous and Overlapping Screens Section 2-11

1, 2, 3... 1. Select all the screen numbers of the child screens you want with the cursor and Space Bar. The screen numbers that you select will be marked with asterisks. 2. When all of the child screens you want have been marked, press the Enter Key. 3. Select scrolling by screen or by line, and then press the Enter Key to select a screen. Asterisks will appear by selected as child screens. For line scrolling, scrolling is done in increments of 8 dots. The NT600M does not have the line scrolling function, so the screen shown below will not be displayed. Also, line scrolling cannot be used with the direct con- nection function.

Omron Programmable Terminal (NT20M) — Continuous and Overlapping Screens Section 2-11 diagram (page 80)
Fig. 87 · Continuous and Overlapping Screens Section 2-11
Page 81 of the Omron Programmable Terminal (NT20M) user manual — Continuous and Overlapping Screens Section 2-11
Page 81 · click to enlarge
Page 81

Continuous and Overlapping Screens Section 2-11

4. Set whether or not you want page numbers displayed at the host and then press the Enter Key.
Omron Programmable Terminal (NT20M) — Continuous and Overlapping Screens Section 2-11 diagram (page 81)
Fig. 88 · Continuous and Overlapping Screens Section 2-11
5. Input the screen comment and press the Enter Key or press the Escape Key to return to step 4. Comments can be up to 24 characters. Note 1. A screen with a numeral edit settings cannot be set as a child screen.
2. When designating screens with numeral displays, character string displays, lamps, touch switches, or bar graphs as child screens, do not set line scrolls. 3. The NT600M has no line scroll function.

Overlapping Screens Register the screen numbers of the child screens you want to display over- lapped. There is no particular order of registration. You can register a maxi- mum of 8 child screens.

Omron Programmable Terminal (NT20M) — Continuous and Overlapping Screens Section 2-11 diagram (page 81)
Fig. 89 · Continuous and Overlapping Screens Section 2-11

1, 2, 3... 1. Select all the screen numbers of the child screens you want with the cursor and Space Bar. Selected screens will be indicated with asterisks. 2. After all of the child screens have been designated, press the Enter Key. 3. Input the screen comment, and press the Enter Key or press the Escape Key to return to step 2. Comments can be up to 24 characters.

Page 82 of the Omron Programmable Terminal (NT20M) user manual — 2-12 Screen Attributes
Page 82 · click to enlarge
Page 82

Screen Attributes Section 2-12

displays, lamps, touch switches, or bar graphs, be sure that these various display elements do not overlap. 2. Only screen attributes set for the parent screen will be used. Parent screen attributes will not change unless they are changed directly (i.e., changing child screen attributes will not affect parent screen attributes).

2-12 Screen Attributes

You can set attributes for one screen at a time, or for multiple screens togeth- er. The following attributes can be set: buzzer, history record, bit input, and alarm output.

1, 2, 3... 1. Go to the Screen Selection Display. 2. If you are setting only one screen move the bar cursor to the number of the screen you want to set, and press F4 (Attributes). If you are setting multiple screens at one time, tag the desired screens with the Space Key and then press F4 (Attributes).

tion time will be lengthened. In such cases, returning to the File Selection Display and then enter the Screen Selection Display before performing the operation.

Omron Programmable Terminal (NT20M) — 2-12 Screen Attributes diagram (page 82)
Fig. 90 · 2-12 Screen Attributes

Screen attributes are described in the following table. Set each attribute and then press the Enter Key. The history title is input next.

Screen Designation · Setting Attributes

Page 83 of the Omron Programmable Terminal (NT20M) user manual — Screen Attributes Section 2-12
Page 83 · click to enlarge
Page 83

Screen Attributes Section 2-12

Buzzer Whether or not the buzzer is to sound when the screen is displayed. If the buzzer is set to sound, you can select either continuous or intermittent operation.

History Whether or not the history of the screen is to be recorded. If you set “Yes,” then, when the Programmable Terminal (PT) is operating, all screens have been displayed will be recorded in the PT. You can check the contents of these records by selecting History Records from the Maintenance Menu of the PT. You can also transmit the contents to the Support Tool.

Bit Input (Bit In)

Whether or not the host is to be notified, in the form of a bit input, of the push-down status of touch switches or function keys while the screen is displayed. This setting is not used for RS-232C and RS-422 communications. To enable notification, set either touch switches or function keys to specify the input device of the PT to be used.

Alarm Whether or not the PT alarm output will turn ON when the screen is displayed.

Keypad Set “System” to use the default key layout or “User” to specify a custom key layout.

Backlight Color (Back Col)

Specify white or red as the backlight color if the NT20M-DT131/DN131 is to be used.

Specify “Light” or “Flash” for the screen backlight if the NT20M-DT131/DN131 is to be used.

History Title If the screen history is enabled, the following display will appear requesting a title for the history. If screen attributes are being simultaneously input for more than one screen, the same title will be used for all of the screens. The following display is for multiple screens.

Omron Programmable Terminal (NT20M) — Screen Attributes Section 2-12 diagram (page 83)
Fig. 91 · Screen Attributes Section 2-12

Input the history title, and press the Enter Key to return to the Screen Selec- tion Display. The title can be up to 24 characters.

Attributes Function · Backlight operation (Backlight)

Page 84 of the Omron Programmable Terminal (NT20M) user manual — 2-13 Screen Check
Page 84 · click to enlarge
Page 84

Screen Check Section 2-13

Screen Attribute Displays After the settings have been made, their contents will be displayed in the sta- tus column on the screen listing as letters of the alphabet.

Omron Programmable Terminal (NT20M) — Screen Check Section 2-13 diagram (page 84)
Fig. 92 · Screen Check Section 2-13
B BuzzerBuzz or Beep
C HistoryYes
D Bit InputOn
E AlarmOn
F KeypadUser

G Extended functions (Backlight color or backlight operation): Displayed for the NT20M-DT131/DN131

2-13 Screen Check

When continuous or overlapping screens are received from the PT as a single screen, there is a chance that screen errors may occur in these files. Check to see whether such errors have occurred. You can print out the con- tents of this check.

Screen Errors If a screen that has been designated as a child screen for continuous or overlapping screens is subsequently designated as a parent screen for

Page 85 of the Omron Programmable Terminal (NT20M) user manual — Screen Check Section 2-13
Page 85 · click to enlarge
Page 85

Screen Check Section 2-13

another continuous or overlapping screen, it results in a screen error. A check can be performed as shown below from the Screen Selection Display

Omron Programmable Terminal (NT20M) — Screen Check Section 2-13 diagram (page 85)
Fig. 93 · Screen Check Section 2-13

1, 2, 3... 1. Press NEXT, F3 (Check). A message will appear asking whether or not you want the results of the screen check to be printed out. 2. Select “Yes” or “No” and then press the Enter Key. Regardless of wheth- er you select Yes or No, the results will be displayed on the screen. The contents will be displayed as shown below. The results of the check are printed out in the same form.

Omron Programmable Terminal (NT20M) — Screen Check Section 2-13 diagram (page 85)
Fig. 94 · Screen Check Section 2-13

No. Shows the numbers of all screens designated as parent screens for continuous or overlapping screens.

Error Indicates whether or not there is an error for the child settings.

Contents Shows the numbers of all screens designated as child screens. If any of these child screens has an error, its number will be underlined.

3. For any child screen with an error, redo the continuous or overlapping screens.

Item Contents

Page 86 of the Omron Programmable Terminal (NT20M) user manual — 2-14 Marks
Page 86 · click to enlarge
Page 86

Marks Section 2-14

played. 2. The paper size for printing is A4 (portrait). Other settings can result in printing errors.

2-14 Marks

Marks can be created for display on the PT. If you press F9 on the Screen Selection Display or specify MARK from the Initial Edit Display, the Mark Cre- ation Display will appear. This display is split in half, with a creation display on the right and a reference display on the left. The reference display can be used to display previously created marks for copying all or part of them to the creation display.

Omron Programmable Terminal (NT20M) — 2-14 Marks diagram (page 86)
Fig. 95 · 2-14 Marks

Keys Usable on Mark Creation Display

The dots used to create marks can be manipulated using the mouse and/or the keyboard.

The left mouse button can be clicked to turn ON specific dots or the right mouse button can be clicked to turn OFF specific dots. Either button can be held down to continuously manipulate dots by moving the mouse.

The Up, Down, Left, and Right Keys are used to position the cursor, and the Shift Key is used to set or clear dots one at a time. A continuous series of dots can be cleared or set by using the Shift Key together with the direction keys. The direction keys can also be combined with the Alt Key to move the Creation Display.

to prevent problems with the Caps Key locking.

The Alt Key is used simultaneously with any of the direction keys to move the Creation Display in the designated direction. In addition, you can rotate the Creation Display 90% by simultaneously pressing the Alt Key, the Shift Key, and the Left Key for counterclockwise rotation or Right Key for clockwise ro- tation.

The Escape Key is used to end mark creation and return to the Screen Se- lection Display. When the Support Tool asks for confirmation, press the Re- turn Key to end mark creation or the Escape Key to continue. Be sure to saved required mark data before ending mark creation.

Mark Creation Display

Page 87 of the Omron Programmable Terminal (NT20M) user manual — Marks Section 2-14
Page 87 · click to enlarge
Page 87

Marks Section 2-14

The function keys are used as described in the following table.

F1 Mark Reference (Mk Ref)

Displays designated marks on the reference display.

F2 Copy (Copy) Copies a designated rectangular area on the creation display to another position.

F3 Reference Copy (RCopy)

Copies a designated rectangular area on the reference display to a designated position on the creation display.

F4 Area Set (Set) Sets all of the dots for a designated rectangular area on the Creation Display.

F5 Area Clear (Clr)

Clears all of the dots for a designated rectangular area on the creation display.

F6 Inverse (Inv) Reverses the status of all of the dots on the creation display.

F7 Save (Save) Registers, as a mark, data which is displayed on the creation display.

Setting and Clearing Dots To set or clear dots, move the cursor with the direction keys, and then press the Shift Key. Pressing the Shift Key will clear dots at the cursor position which are set, and set dots at the cursor position which are cleared. By oper- ating the direction keys while continuing to hold down the Shift Key, you can set or clear a continuous series of dots. The results of setting or clearing dots are always displayed inside of brackets at the top of the creation display.

Dots can also be set and clear using the mouse. Use the left mouse button to set dots and the right mouse button to clear them. Dots will be continuously set or cleared if the mouse button is held down while moving the mouse.

Mark Reference F1 is used to display designated marks on the Reference Display. You can copy the contents of the reference display to the creation display with F3 (Reference Copy). (See page 84.)

1, 2, 3... 1. Press F1 (Mark Reference), to display the Mark List Display.

Omron Programmable Terminal (NT20M) — Marks Section 2-14 diagram (page 87)
Fig. 96 · Marks Section 2-14
2. The mark you have input will be displayed on the Reference Display.

Function Keys · Key Key Function

Page 88 of the Omron Programmable Terminal (NT20M) user manual — Marks Section 2-14
Page 88 · click to enlarge
Page 88

Marks Section 2-14

3. Press the Escape Key to return to the Creation Display.

Copy F2 is used to copy a designated rectangular area on the creation display to another position. This operation can be canceled at any point by pressing the Escape Key.

starting point, ending point, etc. If you are not sure of the position of the cur- sor, move it with direction keys. 1, 2, 3... 1. If you press F2 (Copy), the following screen will be displayed.

Omron Programmable Terminal (NT20M) — Marks Section 2-14 diagram (page 88)
Fig. 97 · Marks Section 2-14
2. Move the cursor with the direction keys, and then enter the starting point with the Enter Key. The starting point you have entered will be displayed in reverse video. 3. Designate the ending point for the area to be copied. The ending point you have entered will be displayed in reverse video.
Omron Programmable Terminal (NT20M) — Marks Section 2-14 diagram (page 88)
Fig. 98 · Marks Section 2-14
4. Use the direction keys to move the cursor, and then press the Enter Key to copy the designated data to the cursor position.

Reference Copy F3 is used to copy a designated rectangular area on the reference display to a designated position on the creation display.

Page 89 of the Omron Programmable Terminal (NT20M) user manual — 2-15 Stand-alone Operation
Page 89 · click to enlarge
Page 89

Stand-alone Operation Section 2-15

Operation is basically the same as for copying with F1 except that the copy is designated on the reference display and created on the creation display.

Area Set F4 is used to fill in a designated area on the creation display.

Area designation is basically the same as for copying with F1.

Area Clear F5 is used to clear all of the dots for a designated rectangular area on the creation display. After being cleared, they are represented by small dots.

Area designation is basically the same as for copying with F1.

Inverse F6 is used to reverse all of the dots on the creation display.

Area designation is basically the same as for copying with F1.

Save F7 is used to register data in the creation display as a mark.

1, 2, 3... 1. Enter F7 (Save), the mark list will be displayed. 2. Specify the position in which to save the mark. If you specify a position that already contains a mark, the existing mark will be overwritten by the new one. 3. Press the Enter Key. Saving can be canceled by pressing the Escape Key.

You can confirm that the mark has been saved by pressing F1.

Ending Mark Creation Press the Escape Key when finished creating mark to end mark creation and return to the Screen Selection display. A confirmation display will appear. Press the Enter Key to confirm or press the Escape Key to continue mark creation.

creation is canceled at the confirmation display, however, any unsaved data will be maintained.

2-15 Stand-alone Operation

Stand-alone operation allows the PT touch switches, function keys, and Ex- pansion I/O Units to be used to switch screens without receiving instructions from a host. The Support Tool must be used to set up stand-alone operation.

Precautions When screens are changed during stand-alone operation, a screen number request response is sent from the PT to the host.

If the same key number is allocated in multiple child screens, the key will be effective only in the child screen with the smallest screen number.

The following screen numbers can be set.

NT20M1 to 250 NT600M: 1 to 1,000

The following touch switches and function keys can be allocated.

Touch switches: 000 to 031 Function keys DF___: F1 to F12 Other: 01 to 31

Numeral editing will take priority if both numeral editing and stand-alone op- eration are specified for the same screen. Although both numeral editing and stand-alone operation use function keys and touch switch, the following li- mitation apply to stand-alone operation if numeral editing is also being used.

Page 90 of the Omron Programmable Terminal (NT20M) user manual — Stand-alone Operation Section 2-15
Page 90 · click to enlarge
Page 90

Stand-alone Operation Section 2-15

PT with Touch Panels (DT___) Touch switches 231 to 255 cannot be used.

PT with Function Keys (DF___) Stand-alone operation is not supported.

PT without Function Keys (DN___) 12-key Function Key Units Stand-alone operation is not supported.

32/16 Terminals F1 to F12 and F17 to F29

10/02 Terminals Numeral editing not supported. F1 to F10 can be used for stand-alone operation.

Operation Select EXTEND from the Initial Edit Display to access the Extended Features Display shown below. This display will appear only if direct connection is set to No in the Tool Settings.

Omron Programmable Terminal (NT20M) — Stand-alone Operation Section 2-15 diagram (page 90)
Fig. 99 · Stand-alone Operation Section 2-15

Use the following procedure to allocate screens to switches/function keys.

1, 2, 3... 1. Press the Enter Key to access the Stand-alone Setting Display.

Omron Programmable Terminal (NT20M) — Stand-alone Operation Section 2-15 diagram (page 90)
Fig. 100 · Stand-alone Operation Section 2-15

PT Limitations · Extended Features Display

Page 91 of the Omron Programmable Terminal (NT20M) user manual — 2-16 Edit
Page 91 · click to enlarge
Page 91

Edit Section 2-16

2. Move the cursor to the touch switch/function key to which a screen is to be allocated. F1 will correspond to 000; F2, to 001; etc. 3. Input the screen number to be allocated to the touch switch/function key and press the Enter Key. 4. Repeat steps 2. and 3. until all desired screen have been set. 5. Press the Escape Key to return to the Extended Features Display.

Restrictions The following touch switches/function keys can be used depending on the model of the PT. Refer to the Precautions section, above, for restrictions when using numeral editing with stand-alone operation.

PT Applicable touch switches/function keys

PT with Touch Panels (DT___) 0 to 255

PT with Function Keys (DF___) F1 through F12

PT without Function Keys (DN___) 12-key Function Key Units Stand-alone operation is not supported.

32/16 Terminals F1 to F32

10/02 Terminals F1 to F10

2-16 Edit

The cut and paste operations under EDIT on the Initial Edit Display can be used to copy, move, or delete previously created elements such as character strings and graphics. The Edit Display will appear.

Omron Programmable Terminal (NT20M) — 2-16 Edit diagram (page 91)
Fig. 101 · 2-16 Edit

Key followed by the Space Bar from the Edit Display.

Copy Use the following procedure to copy existing elements on the screen.

1, 2, 3... 1. Specify COPY from the Cut and Paste Display 2. Move the cursor to designate the starting point of the copy area and press the Enter Key. 3. Move the cursor to designate the end point of the copy area and press the Enter Key. The specified copy area will be indicated by a dotted box.

Edit Display

Page 92 of the Omron Programmable Terminal (NT20M) user manual — Edit Section 2-16
Page 92 · click to enlarge
Page 92

Edit Section 2-16

4. Move the cursor to designate the area in which to paste the copy and press the Enter Key. The area to which the copy will be made will be designated by a dotted box when the cursor is moved. 5. Press the Enter Key again when the confirmation message appears to paste the copy or press the Escape Key to cancel the paste and return to step 6. Return to step 2. to make further copies or press the Escape Key to end the copy operation.

Move Use the following procedure to move existing elements on the screen.

1, 2, 3... 1. Specify MOVE from the Cut and Paste Display 2. Move the cursor to designate the starting point of the move area and press the Enter Key. 3. Move the cursor to designate the end point of the move area and press the Enter Key. The specified move area will be indicated by a dotted box. 4. Move the cursor to designate the area to move to and press the Enter Key. The area to which the move will be made will be designated by a dotted box when the cursor is moved. 5. Press the Enter Key again when the confirmation message appears to execute the move or press the Escape Key to cancel the move and re- turn to step 4. 6. Return to step 2. to move other elements or press the Escape Key to end the move operation.

Delete Use the following procedure to delete existing elements on the screen.

1, 2, 3... 1. Specify DELETE from the Cut and Paste Display 2. Move the cursor to designate the starting point of the delete area and press the Enter Key. 3. Move the cursor to designate the end point of the delete area and press the Enter Key. The specified delete area will be indicated by a dotted box. 4. Press the Enter Key again when the confirmation message appears to execute the move or press the Escape Key to cancel the move and re- turn to step 1. 5. Return to step 2. to delete other elements or press the Escape Key to end the delete operation.

Page 93 of the Omron Programmable Terminal (NT20M) user manual — SECTION 3 Managing Screen Data
Page 93 · click to enlarge
Page 93

SECTION 3 Managing Screen Data

This section describes how to copy and delete previously created screens, to change screen comments, and to read screen in from other files.

3-1 Copying Screens 90 3-2 Deleting Screens 91 3-3 Changing Screen Comments 92 3-4 Reading Data from Other Files 93

Page 94 of the Omron Programmable Terminal (NT20M) user manual — Copying Screens Section 3-1
Page 94 · click to enlarge
Page 94

Copying Screens Section 3-1

3-1 Copying Screens

You can copy designated screens to different screens. To copy a screen, first designate the source screen number and then designate the target screen number as described below.

1, 2, 3... 1. Go to the Screen Selection Display.

Omron Programmable Terminal (NT20M) — Copying Screens Section 3-1 diagram (page 94)
Fig. 102 · Copying Screens Section 3-1
2. Move the bar cursor to the number of the screen from which data is to be copied, and then press F1 (Copy).
3. Input the number of the screen to which the data is to be copied, and then press the Enter Key. (For the NT20M, you can input a screen number from 1 to 250; for the NT600M, from 1 to 1,000.) 4. Input a comment of up to 24 characters, and press the Enter Key. 5. When copying is complete, a message will be displayed. Press any key to return to the Screen Selection Display.

message will appear indicating that data already exists and asking you if you wish to overwrite it. If it is overwritten, any data stored up to that point will be cleared. If you choose to overwrite the existing data, press the Enter Key. If

Page 95 of the Omron Programmable Terminal (NT20M) user manual — 3-2 Deleting Screens
Page 95 · click to enlarge
Page 95

Deleting Screens Section 3-2

you wish to cancel, return to the Screen Selection Display by pressing a key other than the Enter Key.

3-2 Deleting Screens

You can delete one or more screens that has previously been set. Screen data can also be deleted from the PT.

1, 2, 3... 1. Go to the Screen Selection Display.

2. If you are only deleting one screen move the bar cursor to the number of the screen you want to delete, and then press F2 (Delete). 3. If you are deleting multiple screens, tag the screen numbers that you want to delete, and then press F2 (Delete).
Omron Programmable Terminal (NT20M) — 3-2 Deleting Screens diagram (page 95)
Fig. 103 · 3-2 Deleting Screens
4. As the default, “Tool” will be displayed in reverse video. To delete a screen from the Support Tool, just press the Enter Key. To delete a screen from the PC, select “NT Host.” A message will appear, asking whether you actually want to delete the data. The following display shows a case where the tag function is used to designate multiple screens for deletion.
Page 96 of the Omron Programmable Terminal (NT20M) user manual — 3-3 Changing Screen Comments
Page 96 · click to enlarge
Page 96

Changing Screen Comments Section 3-3

Omron Programmable Terminal (NT20M) — Changing Screen Comments Section 3-3 diagram (page 96)
Fig. 104 · Changing Screen Comments Section 3-3
5. To confirm deletion, press the Enter Key, or to return to step 1, press any key other than the Enter Key. 6. When the deletion is complete, a message will be displayed. Press any key to return to the Screen Selection Display.

3-3 Changing Screen Comments

You can change designated screen comments.

1, 2, 3... 1. Go to the Screen Selection Display.

2. Move the bar cursor the number of the screen for which you want to change the comment, and press the NEXT, F1 (Change Comments). 3. The comments for the screen you have selected will be displayed in the guide box.
Page 97 of the Omron Programmable Terminal (NT20M) user manual — 3-4 Reading Data from Other Files
Page 97 · click to enlarge
Page 97

Reading Data from Other Files Section 3-4

Omron Programmable Terminal (NT20M) — Reading Data from Other Files Section 3-4 diagram (page 97)
Fig. 105 · Reading Data from Other Files Section 3-4
4. Input the new comment, and then press the Enter Key.

3-4 Reading Data from Other Files

Screens contained in other files can be read into the current file from the Screen Selection Display. Although entire files can be copied from the File Selection Display, copying from the Screen Selection display enables copy- ing one screen at a time into the current file. The files being copied from can be either in the current data directory set in the Tool Settings or in a different drive/directory.

Use the following procedure to read a screen from any accessible file.

1, 2, 3... 1. Change to the Screen Selection Display.

Omron Programmable Terminal (NT20M) — 3-4 Reading Data from Other Files diagram (page 97)
Fig. 106 · 3-4 Reading Data from Other Files
2. Specify the screen to which data is to be read. 3. Press F5 (Read). The following screen will appear.

Screen Selection Display

Page 98 of the Omron Programmable Terminal (NT20M) user manual — Reading Data from Other Files Section 3-4
Page 98 · click to enlarge
Page 98

Reading Data from Other Files Section 3-4

Omron Programmable Terminal (NT20M) — Reading Data from Other Files Section 3-4 diagram (page 98)
Fig. 107 · Reading Data from Other Files Section 3-4
4. Specify insertion or overwriting and press the Enter Key.
5. Specify the data to be copied. You can select from screen data, mark data, number table data, character table data, direct connection information, and I/O comments. A list of the files in the data directory specified in the Tool Settings will be displayed when these settings are confirmed.
Omron Programmable Terminal (NT20M) — Reading Data from Other Files Section 3-4 diagram (page 98)
Fig. 108 · Reading Data from Other Files Section 3-4

6. To read data from the displayed data directory, continue to step 8. To change the directory, press F1. 7. Specify the drive and directory of the file to be read from. A list of files in the specified directory will be displayed. 8. Specify the file from which a screen is to be read. A list of the screens in the specified file will appear. 9. Specify the screen to read. A confirmation message will appear. 10. Confirm the read or cancel the operation by pressing any key but the Enter Key. If the read is confirmed, the screen data will be inserted into the specified screen or the screen that is read will overwrite the speci- fied screen, as specified in step 4.

Page 99 of the Omron Programmable Terminal (NT20M) user manual — SECTION 4 Managing File Data
Page 99 · click to enlarge
Page 99

SECTION 4 Managing File Data

This section describes how to manage file data, including copying and deleting files, as well as settings such as PT histo- ries and initial screens that are set for the entire file.

4-1 Copying Files 96 4-2 Deleting Files 97 4-3 Changing File Titles 98 4-4 Saving PT Histories in Files 98 4-5 Setting Initial Screens 99

memory capacities, this feature is no longer required. Memory capacities are now automatically changed when files are updated and all files are displayed on file lists regardless of capacity.

Page 100 of the Omron Programmable Terminal (NT20M) user manual — Copying Files Section 4-1
Page 100 · click to enlarge
Page 100

Copying Files Section 4-1

4-1 Copying Files

You can copy all the contents of a designated file (i.e., screen data, memory table data, and mark data) to another file. The file can be in any accessible directory.

1, 2, 3... 1. Go to the File Selection Display.

Omron Programmable Terminal (NT20M) — Copying Files Section 4-1 diagram (page 100)
Fig. 109 · Copying Files Section 4-1
2. Press F1 (Copy). A list of files in the data directory specified in the Tool Settings will be displayed.
Omron Programmable Terminal (NT20M) — Copying Files Section 4-1 diagram (page 100)
Fig. 110 · Copying Files Section 4-1

3. To copy a file from the displayed list, go to step 5. To copy a file in a dif- ferent directory, press F1. An input field for the drive and directory names will appear. 4. Specify the drive and directory from which a file is to be copied. A list of files in the specified directory will be displayed. 5. Specify the file to be copied or press the Escape Key to cancel. 6. Input a name of up to 8 normal characters for the file to which the data is to be copied, and then press the Enter Key. 7. Input a title of up to 28 characters, and then press the Enter Key or press the Escape Key to cancel.

Page 101 of the Omron Programmable Terminal (NT20M) user manual — 4-2 Deleting Files
Page 101 · click to enlarge
Page 101

Deleting Files Section 4-2

8. When copying is complete, a message will be displayed. Press any key to return to the File Selection Display.

pear indicating that the file name already exists, and asking you if you wish to overwrite the existing file. If it is overwritten, any data stored up to that point will be cleared. If you wish to overwrite the existing file, press the Enter Key. If you wish to cancel, return to step 6. by pressing a key other than the Enter Key. Then input another name for the new file.

4-2 Deleting Files

You can delete all the contents of a designated file (i.e., screen data, memory table data, and mark data).

1, 2, 3... 1. Go to the File Selection Display.

2. Move the bar cursor to the file which is to be deleted, and press F2 (Delete). A message will appear asking whether you actually want to delete the file. 3. To confirm, press the Enter Key. Press any other key to return to the File Selection Display. 4. When the deletion is complete, a message will be displayed. Press any key to return to the File Selection Display.
Page 102 of the Omron Programmable Terminal (NT20M) user manual — 4-4 Saving PT Histories in Files
Page 102 · click to enlarge
Page 102

Saving PT Histories in Files Section 4-4

4-3 Changing File Titles

You can change file titles that are already set.

1, 2, 3... 1. Go to the File Selection Display.

2. Move the bar cursor to the file for which the title is to be changed, and press F9 (Change Title). An input field will appear for the new title. 3. Input the new title, and then press the Enter Key.

4-4 Saving PT Histories in Files

History information recorded in the PT can be received through the tool inter- face and saved in a file. The file that you save is a text file, so you can check its contents with the MS–DOS “TYPE” command. History files can also be printed. Refer to Section 5 Printing for details.

1, 2, 3... 1. Go to the File Selection Display.

2. Press F5 (History). It does not matter where the cursor is. An input field will appear for the history file name.
Page 103 of the Omron Programmable Terminal (NT20M) user manual — 4-5 Setting Initial Screens
Page 103 · click to enlarge
Page 103

Setting Initial Screens Section 4-5

Omron Programmable Terminal (NT20M) — Setting Initial Screens Section 4-5 diagram (page 103)
Fig. 111 · Setting Initial Screens Section 4-5
Omron Programmable Terminal (NT20M) — Setting Initial Screens Section 4-5 diagram (page 103)
Fig. 112 · Setting Initial Screens Section 4-5
3. Input a file name of up to 8 characters, and then press the Enter Key. While the data is being received from the PT, a message will be displayed indicating that history data is being received. 4. When the data has all been received, a message will be displayed. Press any key to return to the File Selection Display.

indicating that the file name already exists, and asking you if you wish to overwrite the existing file. If it is overwritten, any data stored up to that point will be cleared. If you wish to overwrite the existing file, press the Enter Key. If you wish to cancel, press a key other than the Enter Key and then input another name for the file.

Saving Files A file name extension is attached to the file name that is input, and the file name is stored in the Tool Settings data directory. For example, if the data directory is set as B: \DATA, and LOGFILE is input as the file name, then the data received will be saved to B: \DATA\LOGFILE.LOG.

The history records are stored in the file first by order of occurrence and then by order of frequency.

4-5 Setting Initial Screens

The Programmable Terminal will display a previously designated initial screen when the PT is turned on or reset.

1, 2, 3... 1. Go to the File Selection Display.

Page 104 of the Omron Programmable Terminal (NT20M) user manual — Setting Initial Screens Section 4-5
Page 104 · click to enlarge
Page 104

Setting Initial Screens Section 4-5

2. Move the bar cursor to the file for which you want to set the initial screen, and then press F8 (Initial Screen).
Omron Programmable Terminal (NT20M) — Setting Initial Screens Section 4-5 diagram (page 104)
Fig. 113 · Setting Initial Screens Section 4-5
3. Input the screen number of the initial screen, and then press the Enter Key. (For the NT20M, you can input a screen number from 1 to 250; for the NT600M, from 1 to 1,000.)
4. When the setting has been completed, a message will be displayed. Press any key to return to the File Selection Display.

not be effective unless a file is sent to the PT after the setting has been made. To send the file, press F6 (Transmit) from the File Selection Display. If you do not set a initial screen number, the default setting will be 1 unless the screen is initialized at the PT, in which case the default setting will be 0.

Page 105 of the Omron Programmable Terminal (NT20M) user manual — SECTION 5
Page 105 · click to enlarge
Page 105

SECTION 5

Printing

This sections describes the procedures for printing screen images and other information from the Screen Selection and File Selection Displays.

5-1 Printing Features 102 5-2 Printing from the File Selection Display 102 5-3 Printing from the Screen Selection Display 103

Page 106 of the Omron Programmable Terminal (NT20M) user manual — 5-2 Printing from the File Selection Display
Page 106 · click to enlarge
Page 106

Printing from the File Selection Display Section 5-2

5-1 Printing Features

The F3 Function Key can be used from the File Selection Display or the Screen Selection Display to print out actual screens or to print out data re- lated to screens.

File Selection Display The following can be printed from the File Selection Display.

  • File lists: Include file names, memory settings, memory usage, etc.
  • Screen lists: Includes the screen numbers, comments, and attributes for all screens in a specified file.
  • Screen images: Includes all screens in a specified file. When printing screen images, the items selectable for printing from the Screen Selection Display can also be designated here (see below).
  • Cross references: Includes cross references of the usage of character tables and numeral tables.
  • Screen histories
  • Mark lists
  • Direct connection information

Screen Selection Display The following can be printed from the Screen Selection Display.

  • One or more screen images
  • Screen information
  • Lamp numbers
  • Touch switch numbers
  • Memory table numbers Note 1. NT20M screens are printed up to four screens per page. NT600M

screens and other information are printed on one or more page each. 2. Set the printer up before attempting to print. 3. A printing error may occur f the printer’s SEL switch is ON when printing is started. If this happen, press any key, return to the Screen Selection Display and repeat the printing process from the beginning. 4. The paper size for printing is A4 (portrait). Other settings can result in printing errors. 5. Nothing will be printed if no data exists for a specified item. 6. Detailed information will not be printed for polylines and circles. 7. Only 62 lines will be printed per page before pagination. 8. The maximum length printed for character data is 32 characters. 9. Only child screens will be printed for continuous or overlapping screen unless a screen image is specified. If a screen image is specified for con- tinuous screens, only the first child screen and the screen numbers of the child screens will be printed. If a screen image is specified for overlapping screens, the overlapping screen and the screen numbers of the child screens will be printed.

5-2 Printing from the File Selection Display

1, 2, 3... 1. Go to the File Selection Display 2. Specify the file from which to print. 3. Specify F3. The following display will appear.

Page 107 of the Omron Programmable Terminal (NT20M) user manual — 5-3 Printing from the Screen Selection Display
Page 107 · click to enlarge
Page 107

Printing from the Screen Selection Display Section 5-3

Omron Programmable Terminal (NT20M) — Printing from the Screen Selection Display Section 5-3 diagram (page 107)
Fig. 114 · Printing from the Screen Selection Display Section 5…
4. Specify the item to be printed or press the Escape Key to cancel. Printing will start after user confirmation for all items except for screens, in which case the following display will appear.
Omron Programmable Terminal (NT20M) — Printing from the Screen Selection Display Section 5-3 diagram (page 107)
Fig. 115 · Printing from the Screen Selection Display Section 5…
5. Specify the items to be printed. Printing will start after user confirmation. A message will be displayed during printing and another will appear when printing finishes. The actual image being printed will be displayed when detailed information and screen image are specified.

in character strings printed in detailed information.

5-3 Printing from the Screen Selection Display

1, 2, 3... 1. Go the the Screen Selection Display. 2. If you are printing only one screen, move the bar cursor to the number of the screen you want to print, and press F3 (Print). If you are printing multiple screens at one time, tag the screen numbers that you want to print and then press F3 (Print). The following display will appear.

Page 108 of the Omron Programmable Terminal (NT20M) user manual — Printing from the Screen Selection Display Section 5-3
Page 108 · click to enlarge
Page 108

Printing from the Screen Selection Display Section 5-3

Omron Programmable Terminal (NT20M) — Printing from the Screen Selection Display Section 5-3 diagram (page 108)
Fig. 116 · Printing from the Screen Selection Display Section 5…
3. Specify the items to be printed. Printing will start after user confirmation. The confirmation screen will show the settings. A message will be displayed during printing and another will appear when printing finishes. The actual image being printed will be displayed when detailed information and screen image are specified.
Page 109 of the Omron Programmable Terminal (NT20M) user manual — SECTION 6 Transmitting Data
Page 109 · click to enlarge
Page 109

SECTION 6 Transmitting Data

This section describes the procedures to transfer screen and memory table data between the PT and the Support Software. The procedure to delete screens directly from the PT is also provided.

6-1 Connecting to the PT 106 6-2 Transmitting Data 106 6-3 Receiving Data 110 6-4 Deleting PT Screens 114

Page 110 of the Omron Programmable Terminal (NT20M) user manual — 6-2 Transmitting Data
Page 110 · click to enlarge
Page 110

Transmitting Data Section 6-2

6-1 Connecting to the PT

Before beginning transfer operations, connect the computer to the Program- mable Terminal according to the system configuration shown below.

Omron Programmable Terminal (NT20M) — Transmitting Data Section 6-2 diagram (page 110)
Fig. 117 · Transmitting Data Section 6-2

IBM PC/AT

Omron Programmable Terminal (NT20M) — IBM PC/AT diagram (page 110)
Fig. 118

RS-232C

5.25” floppy disk

3.5” floppy disk

Omron Programmable Terminal (NT20M) — RS-232C diagram (page 110)
Fig. 119

100 to 240 VAC 50 Hz/ 60 Hz

grammable Terminal operation manual.

6-2 Transmitting Data

Data created with the Support Tool (i.e., screen data, memory table data, and mark data) can be transmitted either by file or by screen (i.e., single screens, multiple screens, or memory tables).

24-VDC power supply

Page 111 of the Omron Programmable Terminal (NT20M) user manual — Transmitting Data Section 6-2
Page 111 · click to enlarge
Page 111

Transmitting Data Section 6-2

Transmitting Files When you transmit a file, screen data, memory table data, and mark data registered in the PT is completely overwritten unless the resume operation is set to ON. If the resume operation is ON, memory table data will not be changed.

advance from the maintenance menu to transfer data to the PT’s image data memory.

1, 2, 3... 1. Go to the File Selection Display. 2. Move the bar cursor to the file you want to transmit, and then press F6 (Transmit). A message will appear asking whether you actually want to transmit the file. 3. If you do want to transmit it, press the Enter Key. To return to the File Selection Display, press any key other than the En- ter Key.

Omron Programmable Terminal (NT20M) — Transmitting Data Section 6-2 diagram (page 111)
Fig. 120 · Transmitting Data Section 6-2
4. Select whether or not you want to confirm transmission. Select “Yes” or “No,” and then press the Enter Key. Transfer will begin.
Omron Programmable Terminal (NT20M) — Transmitting Data Section 6-2 diagram (page 111)
Fig. 121 · Transmitting Data Section 6-2
5. To return to the File Selection Display, press the Escape Key.
Page 112 of the Omron Programmable Terminal (NT20M) user manual — Transmitting Data Section 6-2
Page 112 · click to enlarge
Page 112

Transmitting Data Section 6-2

6. When the transmission is complete, a message will be displayed. Press any key to return to the File Selection Display.

Transmitting Screens You can transmit single or multiple screens.

so check these screens carefully before sending them. 2. This operation is not possible if EEPROM is used in the PT. Transfer files only. 1, 2, 3... 1. Go the the Screen Selection Display. 2. If you are transmitting only one screen, move the bar cursor to the num- ber of the screen you want to transmit, and press F6 (Transmit). If you are transmitting multiple screens at one time, tag the screen num- bers that you want to transmit and then press F6 (Transmit).

Omron Programmable Terminal (NT20M) — Transmitting Data Section 6-2 diagram (page 112)
Fig. 122 · Transmitting Data Section 6-2
3. Select screen data. As the default, “Screen Data” will be displayed in reverse video. To select screen data, just press the Enter Key. 4. Select whether or not you want to confirm the transmission, and then press the Enter Key.
Omron Programmable Terminal (NT20M) — Transmitting Data Section 6-2 diagram (page 112)
Fig. 123 · Transmitting Data Section 6-2
Page 113 of the Omron Programmable Terminal (NT20M) user manual — Transmitting Data Section 6-2
Page 113 · click to enlarge
Page 113

Transmitting Data Section 6-2

A message will be displayed asking whether you actually want to trans- mit the data. The following example shows a case where the tag func- tion is used to designate multiple screens for transmission.

Omron Programmable Terminal (NT20M) — Transmitting Data Section 6-2 diagram (page 113)
Fig. 124 · Transmitting Data Section 6-2

5. To confirm, press the Enter Key. To return to step 1, press any key other than the Enter Key. 6. When the transmission is complete, a message will be displayed. Press any key to return to the Screen Selection Display. 7. If you choose to have the data confirmed, then after the data has been transmitted the PT will read the data and check it. This makes possible a more reliable transmission, but it takes more time than if the data is not confirmed. Transmitting Memory Tables

the resume operation to OFF before transferring memory tables. 1, 2, 3... 1. Go to the Screen Selection Display. 2. Press F6 (Transmit). The position of the bar cursor is irrelevant.

3. Select memory tables and then press the Enter Key. 4. Select whether or not you want to confirm the transmission, and then press the Enter Key.
Page 114 of the Omron Programmable Terminal (NT20M) user manual — 6-3 Receiving Data
Page 114 · click to enlarge
Page 114

Receiving Data Section 6-3

A message will be displayed asking whether you actually want to trans- mit the data.

Omron Programmable Terminal (NT20M) — Receiving Data Section 6-3 diagram (page 114)
Fig. 125 · Receiving Data Section 6-3
5. To confirm, press the Enter Key. To return to step 1, press any key other than the Enter Key. 6. When the transmission is complete, a message will be displayed. Press any key to return to the Screen Selection Display.

6-3 Receiving Data

Data registered in the PT (i.e., screen data, memory table data, and mark data) can be received either by file or by screen (i.e., single screens or memory tables). Screen comments, however, are not transferred to PT memory and can thus not be received.

Receiving Files All screen data, memory table data, and mark data together can be received in one file.

1, 2, 3... 1. Go to the File Selection Display. 2. Press F7 (Receive). The position of the bar cursor is irrelevant.

Page 115 of the Omron Programmable Terminal (NT20M) user manual — Receiving Data Section 6-3
Page 115 · click to enlarge
Page 115

Receiving Data Section 6-3

Omron Programmable Terminal (NT20M) — Receiving Data Section 6-3 diagram (page 115)
Fig. 126 · Receiving Data Section 6-3
3. To confirm, press the Enter Key. Press any other key to return to the File Selection Display.
Omron Programmable Terminal (NT20M) — Receiving Data Section 6-3 diagram (page 115)
Fig. 127 · Receiving Data Section 6-3
4. Input the name, using up to 8 characters, of the file in which the transmitted data is to be stored, and then press the Enter Key. 5. Input a title of up to 28 characters, and press the Enter Key. 6. When transmission is complete, a message will be displayed. Press any key to return to the File Selection Display.

indicating that the file name already exists, and asking you if you wish to overwrite the existing file. If it is overwritten, any data stored up to that point will be cleared. If you wish to overwrite the existing file, press the Enter Key. If you wish to cancel, return to step 1 by pressing a key other than the Enter Key and then input another name for the file.

1, 2, 3... 1. Go to the Screen Selection Display. 2. Press F7 (Receive). The position of the bar cursor is irrelevant.

Receiving Screens

Page 116 of the Omron Programmable Terminal (NT20M) user manual — Receiving Data Section 6-3
Page 116 · click to enlarge
Page 116

Receiving Data Section 6-3

Omron Programmable Terminal (NT20M) — Receiving Data Section 6-3 diagram (page 116)
Fig. 128 · Receiving Data Section 6-3
3. Select screen data. As the default, “Screen Data” will be displayed in reverse video. To select screen data, just press the Enter Key.
Omron Programmable Terminal (NT20M) — Receiving Data Section 6-3 diagram (page 116)
Fig. 129 · Receiving Data Section 6-3
4. Input the number of the screen in the PT that you want the Support Tool to receive, and then press the Enter Key.
Page 117 of the Omron Programmable Terminal (NT20M) user manual — Receiving Data Section 6-3
Page 117 · click to enlarge
Page 117

Receiving Data Section 6-3

Omron Programmable Terminal (NT20M) — Receiving Data Section 6-3 diagram (page 117)
Fig. 130 · Receiving Data Section 6-3
5. Input the number of the screen where you want the received data to be stored, and then press the Enter Key. A message will be displayed asking whether you actually want to receive the data.
Omron Programmable Terminal (NT20M) — Receiving Data Section 6-3 diagram (page 117)
Fig. 131 · Receiving Data Section 6-3
6. To confirm, press the Enter Key. To return to step 1, press any key other than the Enter Key. 7. When the reception is complete, a message will be displayed. Press any key to return to the Screen Selection Display. Note 1. If screen data already exists at the screen designated for storage, a mes-

sage will appear indicating that data already exists at the designated number and asking you if you wish to overwrite that data. If it is overwrit- ten, any data stored up to that point will be cleared. If you wish to over- write the existing file, press the Enter Key. If you wish to cancel, return to step 1 by pressing a key other than the Enter Key. 2. Before receiving continuous or overlapping screens, check carefully to ensure that the Support Tool has no errors in screen data.

data set via the Support Tool.

Receiving Memory Tables

Page 118 of the Omron Programmable Terminal (NT20M) user manual — 6-4 Deleting PT Screens
Page 118 · click to enlarge
Page 118

Deleting PT Screens Section 6-4

1, 2, 3... 1. Go to the Screen Selection Display. 2. Press F7 (Receive). The position of the bar cursor is irrelevant.

3. Select memory tables and press the Enter Key. A message will be displayed asking whether you actually want to receive the data.
Omron Programmable Terminal (NT20M) — Deleting PT Screens Section 6-4 diagram (page 118)
Fig. 132 · Deleting PT Screens Section 6-4
4. To confirm, press the Enter Key. To return to step 1, press any key other than the Enter Key. 5. When the reception is complete, a message will be displayed. Press any key to return to the Screen Selection Display.

6-4 Deleting PT Screens

You can delete designated screens from the PT.

1, 2, 3... 1. Go to the Screen Selection Display. 2. Press F2 (Delete). The position of the bar cursor is irrelevant.

Page 119 of the Omron Programmable Terminal (NT20M) user manual — Deleting PT Screens Section 6-4
Page 119 · click to enlarge
Page 119

Deleting PT Screens Section 6-4

Omron Programmable Terminal (NT20M) — Deleting PT Screens Section 6-4 diagram (page 119)
Fig. 133 · Deleting PT Screens Section 6-4
3. Select NT host and, and then press the Enter Key.
Omron Programmable Terminal (NT20M) — Deleting PT Screens Section 6-4 diagram (page 119)
Fig. 134 · Deleting PT Screens Section 6-4
4. Input the number of the PT screen to be deleted, and then press the Enter Key. A message will be displayed asking whether you actually want to delete the screen.
Page 120 of the Omron Programmable Terminal (NT20M) user manual — Deleting PT Screens Section 6-4
Page 120 · click to enlarge
Page 120

Deleting PT Screens Section 6-4

Omron Programmable Terminal (NT20M) — Deleting PT Screens Section 6-4 diagram (page 120)
Fig. 135 · Deleting PT Screens Section 6-4
5. To confirm, press the Enter Key. To abort and return to step 4, press a key other than the Enter Key. 6. When the deletion is complete, a message will be displayed. Press any key to return to the Screen Selection Display.
Page 121 of the Omron Programmable Terminal (NT20M) user manual — SECTION 7 PROM Writer Operations
Page 121 · click to enlarge
Page 121

SECTION 7 PROM Writer Operations

This section describes the procedure for transferring screen file data between a PROM writer and the Support Tool.

7-1 Connecting to a PROM Writer 118 7-2 Transmitting Data to a PROM Writer 118 7-3 Transmitting Data with Verification to a PROM Writer 119 7-4 Receiving Data from a PROM Writer 120

Page 122 of the Omron Programmable Terminal (NT20M) user manual — 7-2 Transmitting Data to a PROM Writer
Page 122 · click to enlarge
Page 122

Transmitting Data to a PROM Writer Section 7-2

7-1 Connecting to a PROM Writer

Before performing operations, connect an IBM PC/AT and a PROM writer. Use RS-232C interface for data communications with the PROM writer. Set the transmission conditions as shown in the following table.

Baud rate 9,600 bps

Data length 8 bits

Transfer format Intel HEX format

IBM PC/AT PROM writer

Omron Programmable Terminal (NT20M) — Transmitting Data to a PROM Writer Section 7-2 diagram (page 122)
Fig. 136 · Transmitting Data to a PROM Writer Section 7-2

be written. 2. Data will not be transferred correctly if the capacity of the RAM buffer in the PROM Writer is less than that of the PT’s ROM.

7-2 Transmitting Data to a PROM Writer

Data created by the Support Tool can be transmitted to a PROM writer by file.

1, 2, 3... 1. Go to the File Selection Display. 2. Move the bar cursor to the file you want to transmit, and press F4 (ROM).

Omron Programmable Terminal (NT20M) — 7-2 Transmitting Data to a PROM Writer diagram (page 122)
Fig. 137 · 7-2 Transmitting Data to a PROM Writer
3. Select Data Sending, and then press the Enter Key. A message will be displayed to verify that the designated file is correct. 4. After verifying the file name, press the Enter Key. A message will be displayed asking whether you actually want to transmit the data.

Parity None · Stop bits 1

Page 123 of the Omron Programmable Terminal (NT20M) user manual — 7-3 Transmitting Data with Verification to a PROM Writer
Page 123 · click to enlarge
Page 123

Transmitting Data with Verification to a PROM Writer Section 7-3

5. The settings for transfer to the PROM writer will be displayed. Check these settings before transferring the data.
Omron Programmable Terminal (NT20M) — Transmitting Data with Verification to a PROM Writer Section 7-3 diagram (page 123)
Fig. 138 · Transmitting Data with Verification to a PROM Writer…
6. After verifying that the PROM writer can receive the data, press the Enter Key. To cancel and return to step 1, press the Escape Key. 7. When the transmission is complete, a message will be displayed. Press any key to return to the Screen Selection Display.

7-3 Transmitting Data with Verification to a PROM Writer

In this case, data created by the Support Tool is sent to a PROM writer by file. After transmission is complete, the data is received back from the PROM writer and checked to see whether it was transmitted correctly. 1, 2, 3... 1. Go to the File Selection Display. 2. Move the bar cursor to the file you want to transmit with verification, and then press F4 (ROM).

3. Select “Verify,” and then press the Enter Key. A message will be displayed to verify that the designated file is correct. 4. After verifying the file name, press the Enter Key. A message will be displayed asking whether you actually want to transmit the data.
Page 124 of the Omron Programmable Terminal (NT20M) user manual — 7-4 Receiving Data from a PROM Writer
Page 124 · click to enlarge
Page 124

Receiving Data from a PROM Writer Section 7-4

5. The settings for transfer to the PROM writer will be displayed. Check these settings before transferring the data.
Omron Programmable Terminal (NT20M) — Receiving Data from a PROM Writer Section 7-4 diagram (page 124)
Fig. 139 · Receiving Data from a PROM Writer Section 7-4

6. After verifying that that PROM writer can receive the data, press the En- ter Key. To cancel and return to step 3, press the Escape Key. 7. When the transmission is complete, the following message will be dis- played and the Support Tool will wait for the data to be sent back from the PROM writer. Transmit the data from the PROM writer. 8. If all of the data received matches the data that was transmitted, a mes- sage will be displayed. To return to step 1, press any key.

7-4 Receiving Data from a PROM Writer

Data can be received from the PROM writer by file.

1, 2, 3... 1. Go to the File Selection Display. 2. Press F4 (ROM). The position of the bar cursor is irrelevant.

3. Select “Receive Data” and then press the Enter Key.
Page 125 of the Omron Programmable Terminal (NT20M) user manual — Receiving Data from a PROM Writer Section 7-4
Page 125 · click to enlarge
Page 125

Receiving Data from a PROM Writer Section 7-4

Omron Programmable Terminal (NT20M) — Receiving Data from a PROM Writer Section 7-4 diagram (page 125)
Fig. 140 · Receiving Data from a PROM Writer Section 7-4
4. Input the name, using up to 8 normal characters, of the file in which the data received is to be stored, and then press the Enter Key. 5. Input a title of up to 28 characters, and press the Enter Key. The following message will be displayed and the Support Tool will wait for the data to be sent from the PROM writer.
Omron Programmable Terminal (NT20M) — Receiving Data from a PROM Writer Section 7-4 diagram (page 125)
Fig. 141 · Receiving Data from a PROM Writer Section 7-4
6. Transmit the data from the PROM writer. 7. When the data has been received, a message will be displayed. To return to step 1, press any key. Note 1. When receiving data from a PROM writer, you need enough disk space to

be able to save a work file used for receiving the data and a storage file for saving the data received. Be sure, therefore, to reserve at least 256 K for the NT20M and 512 K for the NT600M. 2. If the memory capacity setting for the file in which the data received is stored differs from memory capacity setting in Tool Settings, then the file will not be displayed even if you return to the File Selection Display. If that happens, change the setting in Tool Settings. 3. If you designate a new file with the same name as an existing file, a mes- sage will appear indicating that the file name already exists, and asking you if you wish to overwrite the existing file. If it is overwritten, any data

Page 126 of the Omron Programmable Terminal (NT20M) user manual — Receiving Data from a PROM Writer Section 7-4
Page 126 · click to enlarge
Page 126

Receiving Data from a PROM Writer Section 7-4

stored up to that point will be cleared.If you wish to overwrite the existing file, press the Enter Key. If you wish to cancel, return to step 1 by pressing a key other than the Enter Key. Then input another name for the new file.

Page 127 of the Omron Programmable Terminal (NT20M) user manual — Appendix Special Characters
Page 127 · click to enlarge
Page 127

Appendix Special Characters

English Character Codes

Pin 3 of SW1 must be ON to enable English language messages to use the following codes.

Example: Hex code is represented by 30, decimal code by 48, and character by 0.

Code 20 and 32 in the table represents a space, as indicated by “SP”.

Hex Digits 1st 2nd

23. 45- 67- 89-

-0 20 SP 30 0 40 @ 50 P 60 ‘ 70 p 80 Ç 90 É

32 48 64 80 96 112 128 144

-1 21 ! 31 1 41 A 51 Q 61 a 71 q 81 ü 91 æ

33 49 65 81 97 113 129 145

-2 22 ” 32 2 42 B 52 R 62 b 72 r 82 é 92 Æ

34 50 66 82 98 114 130 146

-3 23 # 33 3 43 C 53 S 63 c 73 s 83 â 93 ô

35 51 67 83 99 115 131 147

-4 24 $ 34 4 44 D 54 T 64 d 74 t 84 ä 94 ö

36 52 68 84 100 116 132 148

-5 25 % 35 5 45 E 55 U 65 e 75 u 85 à 95 ò

37 53 69 85 101 117 133 149

-6 26 & 36 6 46 F 56 V 66 f 76 v 86 å 96 û

38 54 70 86 102 118 134 150

-7 27 ’ 37 7 47 G 57 W 67 g 77 w 87 ç 97 ù

39 55 71 87 103 119 135 151

-8 28 ( 38 8 48 H 58 X 68 h 78 x 88 ê 98 ÿ

40 56 72 88 104 120 136 152

-9 29 ) 39 9 49 I 59 Y 69 i 79 y 89 ë 99 Ö

41 57 73 89 105 121 137 153

-A 2A * 3A4A J 5A Z 6A j 7A z 8A è 9A Ü

42 58 74 90 106 122 138 154

-B 2B + 3B ; 4B K 5B [ 6B k 7B { 8B ï 9B ¢

43 59 75 91 107 123 139 155

-C 2C , 3C < 4C L 5C \ 6C l 7C | 8C î 9C £

44 60 76 92 108 124 140 156

-D 2D - 3D = 4D M 5D ] 6D m 7D } 8D ì 9D ¥

45 61 77 93 109 125 141 157

-E 2E . 3E > 4E N 5E ^ 6E n 7E ~ 8E Ä 9E Pt

46 62 78 94 110 126 142 158

-F 2F / 3F ? 4F O 5F _ 6F o 7F 8F Å 9F ƒ

47 63 79 95 111 127 143 159

Page 128 of the Omron Programmable Terminal (NT20M) user manual — Appendix Special Characters
Page 128 · click to enlarge
Page 128

Appendix Special Characters

Omron Programmable Terminal (NT20M) — Appendix Special Characters diagram (page 128)
Fig. 142 · Appendix Special Characters

-0 A0 á B0 C0 D0 E0 α F0 ≡

-1 A1 í B1 C1 D1 E1 β F1 +

-2 A2 ó B2 C2 D2 E2 Γ F2 ≥

-3 A3 ú B3 C3 D3 E3 π F3 ≤

-4 A4 ñ B4 C4 D4 E4 Σ F4 ⌠

-5 A5 Ñ B5 C5 D5 E5 σ F5 ⌡

-6 A6 a B6 C6 D6 E6 m F6 ÷

-7 A7 o B7 C7 D7 E7 τ F7 ≈

-8 A8 ¿ B8 C8 D8 E8 Φ F8 %

-9 A9 B9 C9 D9 E9 Θ F9 .

-A AA BA CA DA EA W FA •

-B AB 1/2 BB CB DB EB δ FB √

-C AC 1/4 BC CC DC EC ∞ FC n

-D AD ¡ BD CD DD ED f FD 2

-E AE « BE CE DE EE ε FE

-F AF » BF CF DF EF ∩ FF

Page 131 of the Omron Programmable Terminal (NT20M) user manual — Revision History
Page 131 · click to enlarge
Page 131

Revision History

A manual revision code appears as a suffix to the catalog number on the front cover of the manual.

Cat. No. V004-E1-2

The following table outlines the changes made to the manual during each revision. Page numbers refer to the previous version.

Revision code Date Revised content

1 September 1991 Original production

2 August 1993 Major revisions for new version of software.

Revision code

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Omron Programmable Terminal (NT20M)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Omron Programmable Terminal (NT20M)

Be the first to ask — other owners or our team will answer.

Original document

Omron Programmable Terminal (NT20M) manual PDF

131 pages·1.3 MB·Satellite TV System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…