Thank you for purchasing the OMRON Comp Air Pro. This product was developed in conjunction with respiratory therapists for the successful treatment of asthma, chronic bronchitis, allergies and other respiratory disorders. The compressor forces air to the nebuliser. When the air enters the nebuliser, it converts the prescribed medication into an aerosol of microscopic droplets that can easily be inhaled. The Comp Air Pro is a medical device. Operate this device only as instructed by your doctor and/or respiratory therapist.
Medical Purpose This product is intended to be used for inhaling medication for respiratory disorders.
Intended Patients This product should not be used by patients, who are unconscious or are not breathing spontaneously.
Environment This product is intended for use in a medical facility, such as Hospital, clinic and doctor’s office, and in a room of general household.
Durable period Durable periods are as follows, provided the product is used to nebulise saline 10 times a day for 10 minutes each time at room temperature (23°C). Durable period may vary depending on usage environment. Main unit 3 years Nebuliser Kit (Cap, Inhalation Air Inlet, Baffle, Medication Cup) 100 days Mouthpiece 100 days Air Tube 100 days Air Filter 60 days Child Mask 100 days Adapter for Child Mask 100 days
Precautions for use Warnings and cautions described in the instruction manual
should be observed.

Read all the information in the instruction manual and any other literature included in the box before using the device. When using an electrical product, especially when children are present, basic safety precautions should always be followed including the following:


Save these instructions for future reference.


A1.Power Switch A2.Air Connector A3.Filter Cover (* Air filter inside.) A4.Nebuliser Kit Holder A5.Ventilation Slots A6.Storage Compartment Cover A7.Power Cord A8.Power Plug B. Air Tube (PVC, 207cm)
D1.Mouthpiece D2.Adult Mask (PVC) D3.Child Mask (PVC) D4.Nosepiece E. Nebuliser Kit
E1.Cap E2.Inhalation Air Inlet E3.Inhalation Top E4.Vaporiser Head E5.Medication Tank E6.Nozzle E7.Air Tube Connector


F. Spare Air Filters x 5 G. Instruction Manual
H. Warranty Card
Nebuliser Kit, Mouthpiece, Nosepiece, Adapter for Child Mask (SEBS): Polypropylene
Adult Mask (PVC), Child Mask (PVC): PVC Adult Mask (SEBS), Child Mask (SEBS): SEBS Air Tube: PVC and Polypropylene Air Filter: Polyester Air Filter Cover: ABS


attachments before using the device for the first time, or if it has not been used for more than one week.

The compressed air from the compressor is forced through the nozzle, as it does so, it is mixed with the medication in the vaporiser head and forced upwards. The medication is then turned into a fine aerosol and directed upwards by the baffle, where it is broken down into many smaller aerosol particles.

Warning: Clean and disinfect the nebuliser kit, mouthpiece and optional nosepiece or masks before using them for the first time after purchase, if the device has not been used for a long period of time, or if more than one person uses the same device. For directions on cleaning and disinfecting the parts of the device refer to Section 5 in this instruction manual.
the air filter”.)

Check that the power switch is in the position.
Operating instructions


reference only. The scale on the outside of the tank is with vaporiser head in place. The scale on the inside is with no vaporiser head. Please use the scale on your syringe or vial for accurate measurement of medication.


Attaching the mouthpiece Make sure you also attach the cap, when using the mouthpiece. 1) Attach the cap to the inhalation air inlet. 2) Attach the mouthpiece to the inhalation top.

Attaching the adult mask (PVC) Attach the mask to the inhalation top.
attach the cap.
Attaching the child mask (PVC) Attach the mask to the inhalation top. 1) Attach the cap to the inhalation air inlet. 2) Attach the child mask to the inhalation top.
Attaching the nosepiece Attach the cap when using the nosepiece. 1) Attach the cap to the inhalation air inlet. 2) Attach the nosepiece to the inhalation top.






Press the power switch to the off ( ) position.
result in the compressor overheating or malfunctioning.
To stop nebulisation


Prepare your mouthpiece according to Section 3.9. Insert the mouthpiece into your mouth and inhale the medication breathing normally. Exhale as normal through the mouthpiece.
Prepare your nosepiece according to Section 3.9. Inhale the medication through the nosepiece, as shown and exhale through the mouth.
Using the adult mask (PVC) Attach the mask so that it covers your nose and mouth and inhale the medication. Exhale through the mask.
attach the cap.
Using the child mask (PVC)
Prepare your child mask according to Section 3.9. Attach the mask so that it covers your nose and mouth and inhale the medication. Exhale through the mask.
Using the mouthpiece · Using the nosepiece



5.1 Cleaning
Following the cleaning instructions after each use will prevent any remaining medication in the tank from drying, resulting in the device not nebulising effectively and also for preventing infections.

For instructions on how to disinfect the parts, see the following section.

Care and maintenance


storage compartment if they are still wet. Store the unit in a clean and dry location.
Always clean before disinfection. (See Section 5.1) Always disinfect the medication tank, mouthpiece and other nebulising parts after the last treatment of the day. To disinfect the parts, use one of the methods described below: A.Use a commercially available disinfectant. Follow the instructions provided by
the disinfectant manufacturer.
B.Parts may be boiled between 15 to 20 minutes (except for PVC mask). After boiling, carefully remove the parts, shake off excess water and allow to air dry in a clean environment.

The vaporiser head is an important part that is used to vaporise medication. Be sure to observe the following precautions when handling it.
Baffle · Vaporiser head

To keep your device in the best condition and protect the device from damage follow these directions:
Benzene · Thinner

On average, the air filter should be changed every 60 days or so, or when the filter has changed colour from white.

Remove the old air filter with a sharp object, such as a toothpick, and insert the new air filter.

Check the following if your unit should fail during operation. You can also refer to the pages of this manual for complete instructions.
Check that the plug is inserted in an electrical outlet. Unplug then reinsert the plug if necessary.
Nothing happens when the power switch is pressed.
Is the power plug plugged into an electrical outlet?
Is there medication in the medication tank? Fill the medication tank.
Is there too much/little medication in the medication tank?
Add the correct amount of medication to the medication tank.
Is the vaporiser head missing and not assembled correctly?
Attach the vaporiser head correctly.
Is the nebuliser kit assembled correctly?
Assemble the nebuliser kit correctly.
Is the nozzle blocked? Make sure that the nozzle is free of blockages.
No nebulisation or low nebulisation rate, when the power is on.
Make sure that the nebuliser kit is not tilted at an angle of more than 45 degrees.
Is the nebuliser kit tilted at a sharp angle?
Make sure that the air tube is correctly connected to the compressor and nebuliser.
Is the air tube connected correctly?
Is the air tube folded or damaged?
Make sure that the air tube does not contain kinks.
Is the air tube blocked? Make sure that the air tube is free of blockages.
Is the air filter dirty? Replace the air filter with a new one.
The device is abnormally loud.
Is the air filter cover attached correctly?
Attach the air filter cover correctly.
The device is very hot. Are the ventilation slots blocked?
Do not block the ventilation slots.
Symptom Cause Remedy

Name: Comp Air Pro Model: OMRON NE-C29-E Type: Non-heating compressor nebuliser Electrical: 220 - 240V, 50/60 Hz Power Consumption: 192VA Operating Temperature/ Humidity:
+10°C to +40°C 30% to 85% RH
Storage Temperature/ Humidity/Air Pressure:
-20°C to +60°C 10% to 95% RH 700 - 1060 hPa
Weight: Approx. 2.3kg (compressor only) Dimensions: Approx. 186 (W) × 180 (H) × 216 (D) mm Contents: Compressor, Nebuliser Kit, Air Tube (PVC, 207cm), 5 pcs Replacement Filters, Mouthpiece, Adult Mask (PVC), Child Mask (PVC), Nosepiece, Instruction Manual.

Technical data for the OMRON Comp Air Pro compressor with the OMRON V.V.T. (Virtual Valve Technology) Nebuliser kit:
Sound: Noise level (at 1 m distance) 60 db Nebulisation Rate: 0.4 ml/min (by weight loss) Aerosol Output: **0.4 ml (2ml, 1%NaF) Aerosol Output Rate: **0.06 ml/min (2ml, 1%NaF)
Result of cascade impactor **measurements for particle size with OMRON Comp Air Pro (NE-C29-E) and OMRON V.V.T. Nebuliser kit

Cumulative % particle mass of sodium fluoride under size 100
*MMAD = Mass Median Aerodynamic Diameter **Independently measured at SolAero Ltd., Canada, Dr. John Dennis, according to EN 13544-1

= Type B = Type B
= Class ll = Read the instruction manual carefully
In order to regulate the requirements for EMC (Electro Magnetic Compatibility) with the aim to prevent unsafe product situations, the EN60601-1-2 standard has been implemented. This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices.
This medical device manufactured by OMRON Healthcare conforms to this EN60601-1-2:2007 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: • Do not use mobile (cellular) telephones and other devices, which generate strong electrical or electromagnetic fields, near the medical device. This may result in incorrect operation of the unit and create a potentially unsafe situa- tion. Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case the distance is shorter.
Further documentation in accordance with EN60601-1-2:2007 is available at OMRON Healthcare Europe at the address mentioned in this instruction manual. Documentation is also available at www.omron-healthcare.com

Correct Disposal of This Product (Waste Electrical & Electronic Equipment)
This marking shown on the product or its literature, indicates that it should not be disposed of, with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.
This product does not contain any hazardous substances.




Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002 JAPAN
EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp THE NETHERLANDS www.omron-healthcare.com
OMRON HEALTHCARE UK LTD. Opal Drive Fox Milne, Milton Keynes, MK15 0DG, U.K.
OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH John-Deere-Str. 81a, 68163 Mannheim, GERMANY www.omron-medizintechnik.de
OMRON SANTÉ FRANCE SAS 14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, FRANCE
Made in China



Modèle NE-C29-E

DE
IT
ES
NL
RU
AR
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Nothing happens when the power switch is pressed. | Is the power plug plugged into an electrical outlet? | Check that the plug is inserted in an electrical outlet. Unplug then reinsert the plug if necessary. | p.22 |
| No nebulisation or low nebulisation rate, when the power is on. | Is there medication in the medication tank? | Fill the medication tank. | p.22 |
| No nebulisation or low nebulisation rate, when the power is on. | Is there too much/little medication in the medication tank? | Add the correct amount of medication to the medication tank. | p.22 |
| No nebulisation or low nebulisation rate, when the power is on. | Is the vaporiser head missing and not assembled correctly? | Attach the vaporiser head correctly. | p.22 |
| No nebulisation or low nebulisation rate, when the power is on. | Is the nebuliser kit assembled correctly? | Assemble the nebuliser kit correctly. | p.22 |
| No nebulisation or low nebulisation rate, when the power is on. | Is the nozzle blocked? | Make sure that the nozzle is free of blockages. | p.22 |
| No nebulisation or low nebulisation rate, when the power is on. | Is the nebuliser kit tilted at a sharp angle? | Make sure that the nebuliser kit is not tilted at an angle of more than 45 degrees. | p.22 |
| No nebulisation or low nebulisation rate, when the power is on. | Is the air tube connected correctly? | Make sure that the air tube is correctly connected to the compressor and nebuliser. | p.22 |
| No nebulisation or low nebulisation rate, when the power is on. | Is the air tube folded or damaged? | Make sure that the air tube does not contain kinks. | p.22 |
| No nebulisation or low nebulisation rate, when the power is on. | Is the air tube blocked? | Make sure that the air tube is free of blockages. | p.22 |
| No nebulisation or low nebulisation rate, when the power is on. | Is the air filter dirty? | Replace the air filter with a new one. | p.22 |
| The device is abnormally loud. | Is the air filter cover attached correctly? | Attach the air filter cover correctly. | p.22 |
| The device is very hot. | Are the ventilation slots blocked? | Do not block the ventilation slots. | p.22 |