Page 1 of the Omron Safety Door Switch (D4BL) user manual — 1. Operation Key Type
Page 1 · click to enlarge
Page 1

Guard Lock Safety-door Switch D4BL

Release Protective Cover Locks Using Controller Signals or Pushbutton Switches after the Cutting Tool Stops Moving Due to Inertia

Omron Safety Door Switch (D4BL) — Guard Lock Safety-door Switch D4BL diagram (page 1)
Fig. 1 · Guard Lock Safety-door Switch D4BL
  • A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety is achieved using a mechanism where the lock is only released when voltage is applied to the solenoid.
  • Conforms to EN (TÜV) standards corresponding to the CE marking.
  • Approved by UL, CSA, BIA, SUVA and CCC standards.
  • The Switch contact is opened by a direct opening mechanism (NC contacts only) when the protective cover is opened. Direct opening mechanism that is EN-approved is indicated by on the Switch.
  • Auxiliary release key ensures easy maintenance and unlocks the door in the case of a power failure.
  • Tough aluminum die-cast body incorporating a switch box with degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.
  • Equipped with a horizontal and vertical conduit opening.
  • Models incorporating easy-to-see indicators for monitoring and those using an adjustable Operation Key for a double door are available.
  • The mounting direction of the head can be changed to allow the Operation Key to be inserted from four directions.

“Precautions for All Safety Door Switches” on page A-2.

Model Number Structure

  • Model Number Legend

Switch

1 2 3 4 5

1. Conduit Size (2-conduit)

4. Door Lock and Release (Auxiliary Release Key is Incorporated by All Models)

1: PG13.5 2: G1/2 3: 1/2-14NPT

A: Mechanical lock/24-VDC solenoid release B: Mechanical lock/110-VAC solenoid release G: 24-VDC Solenoid lock/Mechanical release

2. Built-in Switch (with Safety Switch and Lock Monitor Switch Contacts)

5. Indicator

C: 1NC/1NO (slow-action) + 1NC (slow-action) D: 2NC (slow-action) + 1NC (slow-action)

Blank: Without indicator A: 10 to 115 VAC or VDC driving (with orange and green LED indicator unit)

3. Head Mounting Direction

R: Four mounting directions possible (right-side mounting at shipping)

Operation Key (Order Separately)

D4BL - K

1. Operation Key Type

1. Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal)
Page 2 of the Omron Safety Door Switch (D4BL) user manual — Specifications
Page 2 · click to enlarge
Page 2

Ordering Information

  • List of Models

Switches

Lock methodConduit sizeVoltage for solenoidWithout indicator 1NC/1NO+ 1NC (Slow-action)With LED indicator 1NC/1NO+ 1NC (Slow-action)Without indicator 2NC+ 1NC (Slow-action)With LED indicator 2NC+ 1NC (Slow-action) Mechanical lockPG13.524 VDCD4BL-1CRAD4BL-1CRA-AD4BL-1DRAD4BL-1DRA-A 110 VACD4BL-1CRBD4BL-1CRB-AD4BL-1DRBD4BL-1DRB-A G1/224 VDCD4BL-2CRAD4BL-2CRA-AD4BL-2DRAD4BL-2DRA-A 110 VACD4BL-2CRBD4BL-2CRB-AD4BL-2DRBD4BL-2DRB-A 1/214NPT24 VDCD4BL-3CRAD4BL-3CRA-AD4BL-3DRAD4BL-3DRA-A 110 VACD4BL-3CRBD4BL-3CRB-AD4BL-3DRBD4BL-3DRB-A Solenoid lockPg 13.524 VDCD4BL-1CRGD4BL-1CRG-AD4BL-1DRGD4BL-1DRG-A G1/224 VDCD4BL-2CRGD4BL-2CRG-AD4BL-2DRGD4BL-2DRG-A 1/214NPT24 VDCD4BL-3CRGD4BL-3CRG-AD4BL-3DRGD4BL-3DRG-A

Operation Keys (Order Separately)

Mounting typeModel Horizontal mountingD4BL-K1 Vertical mountingD4BL-K2 Adjustable mounting (Horizontal)D4BL-K3

Specifications

  • Standards and EC Directives
  • Approved Standards
  • Conforms to the following EC Directives: Machinery Directive Low Voltage Directive EN1088
AgencyStandardFile No. TÜV RheinlandEN60947-5-1R9451050 (Direct opening: approved) BIAGS-ET-19Mechanical lock: 9402293 Solenoid lock: 1998 20462-01 SUVASUVAE6186/2.d ULUL508E76675 CSACSA C22.2, No.14LR45746 CQC (CCC)GB14048.52003010305073836

models.

Page 3 of the Omron Safety Door Switch (D4BL) user manual — UL/CSA (UL508, CSA C22.2 No. 14)
Page 3 · click to enlarge
Page 3
  • Approved Standard Ratings

TÜV (EN60947-5-1), CCC (GB14048.5)

ItemStandard modelIndicator model Utilization categoryAC-15AC-15 Rated operating current (I) e3 A6 A Rated operating voltage (U ) e250 V115 V

Use a 10-A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.

UL/CSA (UL508, CSA C22.2 No. 14)

A300

Rated voltageCarry currentCurrentVolt-amperes MakeBreakMakeBreak 120 VAC10 A60 A6 A7,200 VA720 VA 240 VAC30 A3 A
  • Characteristics
Degree of protection (See note 2.)IP67 (EN60947-5-1) (This applies for the Switch only. The degree of protection for the key hole is IP00.) Durability (See note 3.)Mechanical: 1,000,000 operations min. Electrical: 500,000 operations min. (10-A resistive load at 250 VAC) Operating speed0.05 to 0.5 m/s Operating frequency30 operations/min max. Rated frequency50/60 Hz Contact gap2 x 2 mm min. Operating characteristicsDirect opening force: 19.61 N min. (EN60947-5-1) (See note 4.) Direct opening travel: 20 mm min. (EN60947-5-1) (See note 4.) All stroke: 23 mm min. Lock holding strength700 N min. (GS-ET-19) Insulation resistance100 MΩ min. (at 500 VDC) Rated insulation voltage (U) i300 V (EN60947-5-1) Conventional enclosed thermal current (I ) the10 A (EN60947-5-1) Dielectric strength (U ) impImpulse dielectric strength (U ) 4 kV (EN60947-5-1) between terminals of different polarity, between imp each terminal and ground, and between each terminal and non-current-carrying metal part; 2.5 kV between solenoid and ground (EN60947-5-1) Conditional short-circuit current100 A (EN60947-5-1) Pollution degree (operating environment)3 (EN60947-5-1) Protection against electric shockClass I (with ground terminal) Switching overvoltage1,500 V max. (EN60947-5-1) Contact resistance50 mΩ max. (initial value) Vibration resistanceMalfunction: 10 to 55 Hz, 0.35-mm single amplitude Shock resistanceDestruction: 1,000 m/s2 min. (IEC68-2-27) Malfunction: 300 m/s2 min. (IEC68-2-27) Ambient temperatureOperating: –10°C to 55°C (with no icing) Ambient humidityOperating: 95% max. WeightApprox. 800 g

2. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust, oil or water penetration, do not use the D4BL in places where dust, oil, water, or chemicals may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. 3. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40% to 70%. 4. These figures are minimum requirements for safe operation.

Page 4 of the Omron Safety Door Switch (D4BL) user manual — R LED
Page 4 · click to enlarge
Page 4

Solenoid Coil Characteristics

Item24-VDC mechanical lock models110-VAC mechanical lock models24-VDC solenoid lock models Rated operating voltage24 VDC +10% (100% ED) −15%110 VAC ±10% (50/60 Hz)24 VDC +10% (100% ED) −15% Current consumptionApprox. 300 mAApprox. 98 mAApprox. 300 mA InsulationClass F (130°C or less)

Indicator Characteristics

ItemLED Rated voltage10 to 115 VAC/VDC Current leakageApprox. 1 mA Color (LED)Orange, green

Connections

  • Contact Form (Diagrams Show State with Key Inserted and Lock

Engaged)

ModelContactOperating patternRemarks D4BL-@C@@-@1NC/1NO+1NCZb 31 32 11 12 24 23Lock position a ON a o Stroke Operation Key Extraction T insertion complecompletion a tion position position uOnly NC contacts 11-12 nd 31-32 have an pproved direct pening mechanism. he terminals 11-12 nd 23-24 can be sed as unlike poles. D4BL-@D@@-@2NC+1NCZb 31 32 11 12 22 21Lock position 2 ON h d Stroke Operation Key Extraction insertion complecompletion T tion position position a uNC contacts 11-12, 1-22, and 31-32 ave an approved irect opening mechanism. he terminals 11-12 nd 21-22 can be sed as unlike poles.
Omron Safety Door Switch (D4BL) — Engaged) diagram (page 4)
Fig. 2 · Engaged)
Omron Safety Door Switch (D4BL) — Engaged) diagram (page 4)
Fig. 3 · Engaged)
  • Indicator Unit

Dimensions Internal Circuit

Two, 7 dia. Four terminal plates

10 to 115 VAC/DC

R

Omron Safety Door Switch (D4BL) — R diagram (page 4)
Fig. 4

Z D

26.8 53.2 57.2

R LED

0.3 5.6

2 10.6 (12.6)

(35) 26.2 (61.2)

Show 7 more labels / short text on this page
(Safety circuit side) · (Monitor circuit side) · (7) · Two LED indicators · (16) · (16) · Constant-current diode
Page 5 of the Omron Safety Door Switch (D4BL) user manual — Connections
Page 5 · click to enlarge
Page 5
  • Circuit Connection Example
  • Terminals 11 and 32 are connected internally and so connect terminals 12 and 31 for safety-circuit input. (GS-ET-19).
  • When using indicators, connect them to the auxiliary circuit side (monitor circuit) or the solenoid input terminals as shown below.
  • The indicators can be used to confirm the open/closed status of the door, the ON/OFF status of the power supply, and the ON/OFF status of the solenoid.
  • Do not connect the indicators in parallel with the direct opening contact. If the indicators are broken, a short-circuit current may flow, causing equipment to malfunction.
  • The 24-VDC solenoid terminals have polarity. Confirm the polarity before wiring.
  • Be sure to use a special pushbutton switch to stop and start machinery and release locks.
1. Orange: Lights when the solenoid turns ON. Green: Lights when the door opens.
Omron Safety Door Switch (D4BL) — Connections diagram (page 5)
Fig. 5 · Connections
2. Orange: Lights when the solenoid turns ON. Green: Lights when power turns ON.
E1 11 12 31 32 Solenoid 23 24 LED (orange) E2 LED (green)(+) (−) circuit circuit) Safetycircuit (Ground side)
E1 (+ 11 12 31 32 Solenoid 23 24 LED (orange) E2 (− LED (green)) ) circuit circuit) Safetycircuit (Ground side)
3. Orange: Lights when the solenoid turns ON. Green: Lights when door closes.
4. Orange: Lights when the solenoid turns ON. Green: Lights when power turns ON.
E1 11 12 31 32 Solenoid 21 22 LED (orange) E2 LED (green)(+) (−) circuit circuit) Safetycircuit (Ground side)
E1 ( 11 12 31 32 Solenoid 21 22 LED (orange) E2 ( LED (green)+) −) y circuit r circuit) Safetycircuit (Ground side)
Page 6 of the Omron Safety Door Switch (D4BL) user manual — Connections
Page 6 · click to enlarge
Page 6
  • Connection Example with OMRON’s G9SA Safety Relay Unit

G9SA-321-T@ (24 VAC/VDC) + D4BL-@A-@, @B-@ (Mechanical Lock Type) Circuit Diagram (Manual Reset)

Omron Safety Door Switch (D4BL) — Connections diagram (page 6)
Fig. 6 · Connections

S1: Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) S2: Guard Lock Safety-door Switch S3: Reset switch S4: Lock release switch KM1 and KM2: Magnetic Contactor M: 3-phase motor

A1 A2 T11 T12 T31 T32 13 23 33 43 53 61

PE T21 T23 T22 A B 14 24 34

Reset switch S3 K1 and K2 (NC) K1 and K2 (NO)

K3 and K4 (NC) K3 and K4 (NO) KM1 and KM2 (NC) KM1 and KM2 (NO)

Page 7 of the Omron Safety Door Switch (D4BL) user manual — Connections
Page 7 · click to enlarge
Page 7

G9SA-301 (24 VAC/VDC) + D4BL-@G-@ (Solenoid Lock Type) Circuit Diagram (Auto-reset)

Omron Safety Door Switch (D4BL) — Connections diagram (page 7)
Fig. 7 · Connections
2. The lock can be released at any time. Therefore, do not use a model with a solenoid lock in applications where the operator may be exposed to danger when the guard opens. Use a model with a mechanical lock.

S1: Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) S2: Guard Lock Safety-door Switch KM1 and KM2: Magnetic Contactor M: 3-phase motor

Page 8 of the Omron Safety Door Switch (D4BL) user manual — D4BL- @ C @@ - @ D4BL- @ D @@ - @
Page 8 · click to enlarge
Page 8

Nomenclature

D4BL- @ C @@ - @ D4BL- @ D @@ - @

Omron Safety Door Switch (D4BL) — D4BL- @ C @@ - @ D4BL- @ D @@ - @ diagram (page 8)
Fig. 8
Omron Safety Door Switch (D4BL) — D4BL- @ C @@ - @ D4BL- @ D @@ - @ diagram (page 8)
Fig. 9

Operation Key Lock plate

Operation Key Lock plate

Seal ring (NBR) Auxiliary plunger Seal packing (NBR) Rotating lever

Seal ring (NBR) Auxiliary plunger Seal packing (NBR)

Conduit opening (Pull out horizontally)

Conduit opening (Pull out vertically)

Conduit opening (Pull out horizontally)

Connection terminal M3.5

Conduit opening (Pull out vertically)

Connection terminal M3.5

Ground terminal M3.5

Ground terminal M3.5

Omron Safety Door Switch (D4BL) — D4BL- @ C @@ - @ D4BL- @ D @@ - @ diagram (page 8)
Fig. 10

The head can be changed to any of four directions.

Show 15 more labels / short text on this page
Auxiliary release key · Auxiliary release key · Rotating drum · Rotating drum · Lock monitor switch · Lock monitor switch · Operation plunger · Solenoid · Operation plunger · Solenoid · Rotating lever · Safety switch · Safety switch · Seal packing (NBR) · Seal packing (NBR)
Page 9 of the Omron Safety Door Switch (D4BL) user manual — Dimensions
Page 9 · click to enlarge
Page 9

Dimensions

2. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions. 3. There are fluctuations in the contact ON/OFF timing for 2NC contacts. Confirm performance before application.
  • Switches
Omron Safety Door Switch (D4BL) — Dimensions diagram (page 9)
Fig. 11 · Dimensions

Four, 5.3 dia. mounting holes Four, M4 cover clamping screws

Operating CharacteristicsD4BL-@@@@ Key insertion force Key extraction force19.61 N max. 19.61 N max. Movement before being locked15 mm max.
Operating CharacteristicsD4BL-2GRD-AT Key insertion force Key extraction force19.61 N max. 19.61 N max. Movement before being locked15 mm max.
Page 10 of the Omron Safety Door Switch (D4BL) user manual — Adjustable Mounting (Horizontal)
Page 10 · click to enlarge
Page 10
  • Operation Keys

Horizontal Mounting

Vertical Mounting

D4BL-K1

D4BL-K2

Omron Safety Door Switch (D4BL) — Horizontal Mounting diagram (page 10)
Fig. 12 · Horizontal Mounting
Omron Safety Door Switch (D4BL) — Horizontal Mounting diagram (page 10)
Fig. 13 · Horizontal Mounting
Omron Safety Door Switch (D4BL) — Horizontal Mounting diagram (page 10)
Fig. 14 · Horizontal Mounting

53.7 13

78.7 20±0.15 12 40.7

5.3 x 7.3 long mounting hole

25.8 15.6 7.3 15

40±0.15 52.4 15.6 25.8

Two, 2.65R

5.3 5.3 36

2.6 7.5

5.3 11.9 7.5

4 dia. 4 dia.

Adjustable Mounting (Horizontal)

D4BL-K3

Omron Safety Door Switch (D4BL) — Adjustable Mounting (Horizontal) diagram (page 10)
Fig. 15 · Adjustable Mounting (Horizontal)

25.8 15.6

(80.7)

(37.8) 19.5

4 dia.

5.3 dia.

17.5 34.6 M4 Allen-head bolt

Show 6 more labels / short text on this page
Red · Red · Long mounting hole · 12 20 40 · Red · Red
Page 11 of the Omron Safety Door Switch (D4BL) user manual — Dimensions
Page 11 · click to enlarge
Page 11
  • With Operation Key Inserted
Omron Safety Door Switch (D4BL) — Dimensions diagram (page 11)
Fig. 16 · Dimensions

Horizontal direction Operation Key insertion radius R ≥ 1200

Vertical direction Operation Key insertion radius R ≥ 1000

Vertical direction Operation Key insertion radius R ≥ 1000

Red Horizontal direction Operation Key insertion radius R ≥ 1200

Vertical direction Operation Key insertion radius R ≥ 1000

Horizontal direction Operation Key insertion radius R ≥ 250

2. In the above diagrams, the Operation Key is inserted from the front.
Page 12 of the Omron Safety Door Switch (D4BL) user manual — LOCK
Page 12 · click to enlarge
Page 12

Safety Precautions

Refer to the “Precautions for All Switches” on page I-2 and “Precautions for All Safety Door Switches” on page A-2.

  • Precautions for Correct Use

! CAUTION

Do not insert the Operation Key when the door is open. The machine may operate, possibly resulting in injury. Before using the machine, be sure to remove the shock- absorbing damper, which is provided before shipping.

Tightening Torque

Loose screws may result in malfunction. Tighten the screws to the specified torques.

TypeTorque 1M3.5 terminal screw (including terminal screw)0.59 to 0.78 N·m 2Cover mounting screw1.18 to 1.37 N·m 3Head mounting screw0.78 to 0.98 N·m 4M5 body mounting screw (See note.)4.90 to 5.88 N·m 5Operation Key mounting screw2.35 to 2.75 N·m 6Connector1.77 to 2.16 N·m 7Cap screw1.27 to 1.67 N·m
Omron Safety Door Switch (D4BL) — Tightening Torque diagram (page 12)
Fig. 17 · Tightening Torque
  • Precautions for Safe Use
  • Do not use the Switch submersed in oil or water or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering the Switch. (The IP67 degree of protection of the Switch specifies the amount of water penetration after the Switch is submerged in water for a certain period of time.)
  • Although the Switch body is protected from the ingress of dust or water, avoid the ingress of foreign substance through the key hole on the head. Otherwise, accelerated wear or breaking may result.
  • Always attach the cover after completing wiring and before using the Switch. Electric shock may occur if the Switch is used without the cover attached.

head bolt. For a pan head screw, apply a torque of 2.35 to 2.75 N·m

Omron Safety Door Switch (D4BL) — Tightening Torque diagram (page 12)
Fig. 18 · Tightening Torque

Connect a fuse in series with the D4BL in series to protect it from short-circuit damage. The value of the breaking current of the fuse must be calculated by multiplying the rated current by 150% to 200%.

To prevent the D4BL from burning due to overvoltage, insert a protection fuse into the solenoid circuit.

Stopper Installation

Do not use a Switch as a stopper. Be sure to install a stopper as shown in the following illustration when mounting the Switch so that the Operation Key is within 0.5 to 5 mm of the set zone.

Omron Safety Door Switch (D4BL) — Stopper Installation diagram (page 12)
Fig. 19 · Stopper Installation
Omron Safety Door Switch (D4BL) — Stopper Installation diagram (page 12)
Fig. 20 · Stopper Installation

Auxiliary Release Key

The auxiliary release key is used to unlock the D4BL in case of emergency or in case the power supply to the D4BL fails.

Use the enclosed Release Key to change the lock from LOCK to UNLOCK so that the lock will be released and the door can be opened. (Applies only to mechanical locks.)

Omron Safety Door Switch (D4BL) — Auxiliary Release Key diagram (page 12)
Fig. 21 · Auxiliary Release Key

LOCK

UNLOCK

The auxiliary release key applied to the door of a machine room ensures the safety of people adjusting the equipment in the machine room. If the auxiliary release key is set to UNLOCK, the door will not be locked when the door is closed and no power will be supplied to the equipment.

Whenever the lock has been changed to UNLOCK, always return it to LOCK before using the Switch.

Do not use the auxiliary release key to start or stop machines.

To prevent the auxiliary release key from being handled carelessly by unauthorized people, seal the auxiliary release key with sealing wax and the provided seal cap to ensure IP67.

Make sure that the auxiliary release key is kept with the person in charge.

Before attaching the cover to the D4BL, make sure that the auxiliary release key position is set to LOCK.

Gap · Set zone · Auxiliary release key

Page 13 of the Omron Safety Door Switch (D4BL) user manual — (A) (B)
Page 13 · click to enlarge
Page 13

Solenoid Lock Models

Operation Key

The solenoid lock locks the door only when power is supplied to the solenoid. Therefore, the door will be unlocked if the power supply to the solenoid stops. Therefore, do not use solenoid lock models for machines that may be operating and dangerous even after the machine stops operating.

The D4BL is provided with a shock-absorbing damper to protect the D4BL from damage that may result from dropping the D4BL during transportation. Be sure to remove the damper after mounting the D4BL.

The mounting tolerance of the Operation Key is ±0.3 mm vertically or horizontally. Be sure to mount the D4BL correctly without leaning, otherwise the D4BL may soon break or wear out.

Switch and Operation Key Mounting

Mount the D4BL and Operation Key with four M5 screws with washers and tighten each screw to the specified torque.

Observe the specified insertion radius for the Operation Key and insert it in a direction perpendicular to the key hole.

Incorrect

Omron Safety Door Switch (D4BL) — Incorrect diagram (page 13)
Fig. 22 · Incorrect

Greater than ±0.3

Mounting Dimensions

Switch Mounting Dimensions

Incorrect

74±0.1

Greater than ±0.3

100±0.1

The Operation Key for the D4BL is different from the one for the D4BS.

Operation Key Mounting Holes

  • Horizontal Mounting D4BL-K1

Head Direction

The head can be mounted in four directions. To remove the head, turn the head by 45° as shown in figures (A) and (B) below.

20±0.1

To change the direction of the head, make sure that the protruding part of the rotating lever engages with the groove of the plunger. Then turn the head clockwise or counterclockwise to the desired direction. At that time, make sure that the groove of the plunger is located under the rotating lever. If the direction of the head is not set when the plunger is rotated by 45°, the groove of the plunger presses the rotating lever. The head, plunger, or the built-in switch may be damaged as a result.

  • Vertical Mounting D4BL-K2

40±0.1

  • Adjustable Mounting (Horizontal) D4BL-K3

Head Direction Changes

Omron Safety Door Switch (D4BL) — Head Direction Changes diagram (page 13)
Fig. 23 · Head Direction Changes

30±0.1

(A) (B)

Head Bottom View Switch Top View

Omron Safety Door Switch (D4BL) — (A) (B) diagram (page 13)
Fig. 24

Operation plunger and groove mechanism

Rotation lever and protruding part

Show 10 more labels / short text on this page
Four, M5 · Two, M5 · Two, M5 · Two, M5 · Left · Front · (45°) · (45°) · Back · Right
Page 14 of the Omron Safety Door Switch (D4BL) user manual — Others
Page 14 · click to enlarge
Page 14

Mounting the Cover

Normal Positions of Rotating Lever and Plunger

When tightening the cover, first check the specified torque, and then tighten each screw to the that torque. Also, make sure that no foreign material has entered the Switch.

Omron Safety Door Switch (D4BL) — Normal Positions of Rotating Lever and Plunger diagram (page 14)
Fig. 25 · Normal Positions of Rotating Lever and Plunger

When mounting the cover, make sure that the cover and switch box are properly aligned.

Rotating lever (with protruding part)

Be sure to check the mechanical lock and solenoid release functions when mounting the D4BL.

If the head direction is changed, recheck the tightening torque of each of screw. Make sure that no foreign materials will enter through the key hole on the head.

  • Processing and Connecting Cable/Conduit

The following procedures are recommended for mounting and wiring the indicator unit securely.

Cable Connection Example

1. Connect the wires to the terminals in the order shown below for wiring efficiency.

To ensure IP67, use OMRON’s SC-@M and Nippon Flex’s ABS- 08Pg13.5 and ABS-12 Pg13.5 Connectors.

Recommended cable: UL2464-type cable that is AWG20 to AWG18 (0.5 to 1.0 mm2) in size and has seven conductors

Omron Safety Door Switch (D4BL) — Cable Connection Example diagram (page 14)
Fig. 26 · Cable Connection Example

If the 1/2-14NPT is used, cover the cable and conduit end with sealing tape to ensure IP67. Tighten the connector to a torque of 1.77 to 2.16 N·m.

Connect the indicator unit after connecting the seven-conductor cable.

Omron Safety Door Switch (D4BL) — Cable Connection Example diagram (page 14)
Fig. 27 · Cable Connection Example

Tighten each wired terminal clockwise to a torque of 0.59 to 0.78 N·m.

Twist the wire two or three times and make sure that no bare wire exists outside the terminal when tightening the terminal.

Terminal no. Lp (mm) Lv (mm) a (mm)

2. The insulation sheath of the seven-conductor cable must come into contact with the wall of the conduit mouth, side A or side B.

E1 30±2 80±2 8±1

E 2 35 ± 2 75 ± 2

31 45±2 60±2

12 55±2 50±2

23 (21) 65±2 45±2

24 (22) 70±2 35±2

90±2 50±2

Others

Properly attach and securely tighten the provided conduit cap to the unused conduit opening when wiring the D4BL.

Do not touch the solenoid because the solenoid radiates heat while power is being supplied.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. C100-E1-05

In the interest of product improvement, specifications are subject to change without notice.

Show 4 more labels / short text on this page
Switch body · Plunger (with groove) · Built-in switch · Insulation sheath edge
Page 15 of the Omron Safety Door Switch (D4BL) user manual — Certain Precautions on Specifications and Use
Page 15 · click to enlarge
Page 15

Terms and Conditions of Sale

1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron objects to any terms or conditions proposed in Buyer’s purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change with- out notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron’s payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $200 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the impor- tation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importa- tion, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liabil- ity and in addition to other remedies) cancel any unshipped portion of Prod- ucts sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship

ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or oth- erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli- gation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsi- ble for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were prop- erly handled, stored, installed and maintained and not subject to contamina- tion, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Compa- nies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environ- ments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://oeweb.omron.com or contact your Omron representative for pub- lished information. 14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. 15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, inves- tigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or set- tle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. 16. Property; Confidentiality. Any intellectual property in the Products is the exclu- sive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 17. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to “forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. 18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law princi- ples). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provi- sion hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, “including” means “including without limitation”; and “Omron Compa- nies” (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof.

except in “break down” situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall

constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless oth-

erwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security inter- est in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against nor-

mal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original trans- portation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-

Certain Precautions on Specifications and Use

1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Prod- uct in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equip- ment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or prop- erty. Please know and observe all prohibitions of use applicable to this Prod- uct. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO

ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP- ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 2. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. 3. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitabil- ity and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application require- ments. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. 4. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our prac- tice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifica- tions of the Product may be changed without any notice. When in doubt, spe- cial part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. 5. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.

Page 16 of the Omron Safety Door Switch (D4BL) user manual — Contact Information
Page 16 · click to enlarge
Page 16

- . / 0 12 111# # 3 H / - 2 . 2" / 4 #

! 56 # # ! % 11,:,5 # ! % 11,25

( -# % ! 7' 415, $) $* )+,, 6 < 3 = ,, ((& &)&&

! " # 992 ; # ! ;* 2F9 $%& '& &$&(

$ % " =GG < " =GG G ( " =GG

Cat. No. GC SAFETY-3 07/05 Specifications subject to change without notice Printed in USA

Ask about the Omron Safety Door Switch (D4BL)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Omron Safety Door Switch (D4BL)

Be the first to ask — other owners or our team will answer.

Original document

Omron Safety Door Switch (D4BL) manual PDF

16 pages·2.7 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…