Instruction/ maintenance manual of the product 9063366-4A Omron
Go to page of 24
English Français Deutsch Italiano Español Nederlands Türkçe IM-MC-521-E-01-03/2013 9063366-4A Digital Ear Thermometer Model Gentle T emp ® 521 Instruction Manual.
1 EN Import ant Safety Information T o assu re the cor rec t use of the pr odu ct basic s afe ty measu re s should alway s be followed in clud ing the pr ecaution s liste d bel ow . Wa r n i n g: • Ind ic ates a pot enti al ly ha zar dous si tuat io n whi ch, i f no t avo ide d, coul d r esu lt in dea th or s eri ous i njur y .
2 Impo rt ant Sa fety In for matio n • D o no t to uch the infr ared s enso r wit h a finger or breath e o n it. • D o no t at tempt m ea sureme nts whe n the u nit is wet as in accurat e r eadings ma y result.
3 EN 1. Overview Main unit: Display: Infrared sensor Buzzer Battery icon Memory icon Probe cover icon Ear temperature Surface temperature Room temperature T emperature mode Probe Probe cap Probe cover.
4 2. Prep aration 2 .1 Removing the Insu lating T a pe Pull the insulating t a pe out from the battery comp artme nt by catching the outer p art for the first ti me . The un it is tu rn ed on and after 1 m inu te the r oo m tem per ature will app ear o n th e display .
2. Prep ar at ion 5 EN 2 .3 Setting the Buzzer The bu zzer is onl y av ailab le in the Ear Measur em ent Mo de . The buzzer is se t on as def ault . 1. Press the ON/MEM button to tur n on the unit. 2. Press and hold t he ON/MEM button for 3 s econds .
2. Prep ar at ion 6 2 .4 Att aching a Probe Cover Alwa ys us e a ne w an d unda maged OM RON MC -EP2 p robe cove r . 1. Gently twist of f the probe cap. No te : Do n ot forcibly r emove the probe cap . 2. Place a new probe c over on the connection ring.
7 EN 3. Using the Unit 3 .1 T aking a Reading No te s: • Make su re the pr obe cover is attach ed correct ly . • It is reco mm ended tha t yo u mea sure 3 time s with the sam e e ar . If t he 3 m easu reme nts are differe nt, selec t th e highest tem pe rature .
3. Usi ng the Un it 8 Measur ing the temperature of an infant Measu ri ng on a lyi ng bab y . Meas urin g on a sittin g baby . Ligh tly s upp ort the c hild’s body . Lightl y su pport th e chil d’ s bo dy and sli ghtly pu ll the ea r towa rds the bac k.
3. Usi ng the Un it 9 EN 3. Press the ST ART button. The measu re ment is c omp lete in 1 sec ond with a long bee p. The display will lig ht up a nd the “ ” symb ol will flash for 5 se con ds. No te : Y o u can take an othe r mea sur ement after the disp lay ligh t tu rns off with 2 be eps.
3. Usi ng the Un it 10 Surfa ce Mode The unit is se t in t he Ea r M eas ureme nt M ode a s defaul t . The S urfa ce M easure me nt mod e is n ot inten ded for th e body te mper atur e mea sur emen t. The surfac e m ode shows th e a ctual an d u nad justed s urfa ce tem per ature which is differe nt fro m th e bod y tem per ature.
3. Usi ng the Un it 11 EN 3 .2 Using the Memory Function This unit autom atica lly stor es the res ults up to 25 se ts after e ach me asu remen t. No te : If t he memor y is fu ll, the u nit will delet e th e oldes t re adin g. 1. Press the ON/MEM button to tur n on the unit.
12 4. T ro ubleshootin g an d Main tenance 4 .1 T he Icons and Err or Messa ges Error Display Cause Remed y Device stab ilization in p rocess. W a it until stops fla shin g. Pro ve cover is n ot attache d corre ctly . Attach the pr ob e cover again u ntil stops fl ashing.
4. Tro ubl esh oot in g an d M ain ten anc e 13 EN The am bien t tempe ra ture i s n ot w ithin the ran ge betw een 1 0°C and 40 °C ( 50°F - 1 04° F). All ow the t her mo meter to re st in a ro om fo r at l east 30 m inu tes a t room te mpera tur e: 10°C and 40 °C (5 0° F - 1 04° F) .
4. Tro ubl esh oot in g an d M ain ten anc e 14 4 .2 M aintenance • Please check th e d evice if d amage d a fter it is dro pp ed. If unsu re, please c ontact the OM RON r et a il ou tlet or distribut or for having t he dev ice ch ecke d. • The p robe i s the mo st d elicate part of the uni t .
4. Tro ubl esh oot in g an d M ain ten anc e 15 EN 4 .3 Replacing the Batte ry Ba ttery: CR2 03 2 Lithium Butt on Batte ry No te : T o pro tect the en viron ment, disca rd the use d b atteries in a ccordan ce w ith th e local r egu lations r ega rding waste d isposa l pr ocedur e.
16 5. T ec hnica l Dat a Product Descri ption: Digi tal E ar Thermo meter Model: G entle T emp 521 (MC-521- E) Sen sing Unit: Thermopil e T e mperatur e Display: 4- digit, °F display in 0.1 degre e incremen ts 3-digit , °C display in 0.1 degre e increme nts Measu rement Ac curacy: Ear Measure ment Mode ± 0.
5. T echnical Da ta 17 EN Notes: • T he speci ficat ion may be change d wi thout pr ior notic e. • T his O MRON pr oduct is pro duc ed und er the stric t qu ality s ystem of OM RON HEAL T HCARE Co.
5. T echnical Da ta 18 OMRON Digi tal Ear Thermomet e r Model: Gentle T em p 521 (MC-521-E) Information for accompanying documents in the s cope o f IEC60601-1-2:2007 Important i n formation regarding.
19 EN 6. Some Useful Information 6 .1 T emperature mea suremen t s t aken within the ear The Ge ntle T em p 521 Digital E ar Th erm omete r d etects the infr ared h eat give n off by the ea rdrum an d s urrou nding tiss ues, an d it c onverts this hea t into a n e quivalen t ea r temp era ture.
6. Some Us eful In form atio n 20 As a mbi ent temp er ature, sw eat, or sa liva ea sily affects body temper atu re mea sure d unde r th e arm o r th e ton gue , re adin gs ma y be l owe r than the cor e temp era tur e.
6. Some Us eful In form atio n 21 EN 6 .3 Ear temp erature c omp ared to other types of b ody temperatu re The no rmal te mp eratur e va ries acco rd ing to d ifferent loca tions on the body . 6 .4 Questions and ans wers How many tim es can I measur e conse cutivel y? Y ou can me asu re con secu tively up t o th ree tim es.
6. Some Us eful In form atio n 22 Is the te mperature m easured in th e right ea r different from tha t measu red in the lef t ear? Am ong he alth y people , th ere sho uld be no sig nifica nt differenc e in t he m easur em ent resu lts.
Manufacturer EU-representative OMRON HEAL THCARE Co., Ltd. 53, Kunotsubo, T erado-cho, Muko, Kyoto, 617-0002 JAP AN OMRON HEAL THCARE EUROPE B.V . Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www .omron-healthcare.com OMRON HEAL THCARE UK L TD. Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, U.
An important point after buying a device Omron 9063366-4A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Omron 9063366-4A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Omron 9063366-4A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Omron 9063366-4A you will learn all the available features of the product, as well as information on its operation. The information that you get Omron 9063366-4A will certainly help you make a decision on the purchase.
If you already are a holder of Omron 9063366-4A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Omron 9063366-4A.
However, one of the most important roles played by the user manual is to help in solving problems with Omron 9063366-4A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Omron 9063366-4A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center