EN
Omnitron Systems Technology logo
Official user manual

Omnitron Systems Technology Headset Microphone (HM-1000)

21 pages·338 KB·Media Converter·PDF·ENITNLJA
Omnitron Systems Technology Headset Microphone (HM-1000)
Table of Contents 10 sections 1. INTRODUCTION · 1.1 Features · 2. SAFETY INSTRUCTIONS · 3. OPERATING DETERMINATIONS · … ShowHide
Page 1 of the Omnitron Systems Technology Headset Microphone (HM-1000) user manual — 1.1 Features
Page 1 · click to enlarge
Page 1

OPERATING INSTRUCTIONS

Omnitron Systems Technology Headset Microphone (HM-1000) — OPERATING INSTRUCTIONS diagram (page 1)
Fig. 1

HM-1000 Hand-held microphone

For your own safety, please read this user manual carefully

before you initial start-up.

Every person involved with the installation, operation and maintenance of this device has to - be qualilfied - follow the instructions of this manual - consider this manual to be part of the total product - keep this manual for the entire service life of the product - pass this manual on to every further owner or user of the product - include every supplementay update with the original manual

1. INTRODUCTION

Thank you for having chosen an OMNITRONIC HM-1000. If you follow the instructions given in this manual, we can assure you that you will enjoy this device for many years.

Unpack your OMNITRONIC HM-1000.

Please make sure that there are no obvious transport damages. Should you notice any damage, do not take the device into operation and immediately consult your local dealer.

1.1 Features

  • Rugged hand-held microphone Provides high-quality vocal and voice pickup for stages, discotheques, public speaking, theater etc.
  • Operation in the low-interference UHF-band (790-814 MHz)
  • Up to 16 mics with 16 receivers can be operated simultaneously
  • Frequency and sensitivity switchable via mini-switches
  • 193 carrier frequencies switchable in 125 kHz steps
  • Sensitivity switchable in 4 steps
  • Automatic frequency scan possible
  • LCDdisplay with battery capacity and frequency
  • Battery capacity transmission to receiver
  • Lock-function to avoid undesired changes by the user
  • Latest transmission technology in a rugged metal housing
  • Mutefunction for interference free transmission: receiver goes in mute-mode when signal is absent or too weak
  • For 2 x 1.5 V Mignon batteries (type AA)
  • Operation range 100 meters
  • Delivery includes 8 colour caps for the individual mics on stage
Page 2 of the Omnitron Systems Technology Headset Microphone (HM-1000) user manual — 3. OPERATING DETERMINATIONS
Page 2 · click to enlarge
Page 2

2. SAFETY INSTRUCTIONS

This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual.

Keep away from heaters and other heating sources!

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.

Please note that damages caused by manual modifications on the device or unauthorized operation by unqualified persons are not subject to warranty.

Keep away children and amateurs from the device and the batteries!

3. OPERATING DETERMINATIONS

This device is a hand-held microphone for high-quality vocal and voice pickup. This product is only allowed to be operated with 2 x 1.5 V Mignon batteries, AA and was designed for indoor use only.

Batteries are hazardous waste which need to be disposed of appropriately. If the device is to be disposed, the batteries have to be removed first.

Make sure that the poles are correct when inserting the batteries.

Never let batteries lying around openly as there is the danger that these can be swallowed by children or domestic animals. Immediately consult a doctor when batteries are swallowed!

Leaking or damaged batteries can cause irritations when getting into contact with the skin. In this case use appropriate protective gloves.

Make sure that the batteries cannot be short-circuited, thrown into the fire and be charged. There is a danger of explosion.

Never spill any liquids on the device. Should any liquid enter the device nevertheless, remove the batteries immediately. Please let the device be checked by a qualified service technician before you operate it again. Any damages caused by liquids having entered the device are not subject to warranty!

Do not shake the device. Avoid brute force when operating the device.

Do not operate the device in extremely hot (more than 30° C) or extremely cold (less than 5° C) surroundings. Keep away from direct insulation (particularly in cars) and heaters.

Do not permit operation by persons not qualified for operating the device. Most damages are the result of unprofessional operation!

Never use solvents or aggressive detergents in order to clean the device! Rather use a soft and damp cloth.

Please use the original packaging if the device is to be transported.

Please consider that unauthorized modifications on the device are forbidden due to safety reasons! If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void.

Page 3 of the Omnitron Systems Technology Headset Microphone (HM-1000) user manual — 3.1 Approval
Page 3 · click to enlarge
Page 3

3.1 Approval This wireless microphone system was tested in accordance with the European standards EN 300422-2, EN 301489-09 and EN 60065. Consequently, this product adheres to the R&TTE-Directive of the European Union and does not need an individual EC type examination of every member state. In some countries, the operation of this wireless microphone system needs to be approved by your telecoms regulatory authority. Please refer to your authority as listed below:

Telecoms & Postal Regulatory Authorities in Europe Austria Rundfunk und Telekom Regulierungs-GmbH www.rtr.at Belgium Belgian Institute of postal services and telecommunications (BIPT) www.bipt.be Czech Republic Czech Telecommunication Office www.ctu.cz Denmark National Telecom Agency www.tst.dk Finnland Finnish Communications Regulatory Authority (FICORA) www.ficora.fi France Autorité de Régulation des Télécommunications (ART) www.art-telecom.fr Greece National Telecommunications Commission (EET) www.eett.gr Hungary Communication Authority (HIF) www.hif.hu Iceland Post and Telecom Administration (PTA) www.pta.is Ireland Commission for Communications Regulation (ComReg) www.comreg.ie Italy Italian Communications Authority (AGC) www.agcom.it Latvia Telecommunication State Inspection www.vei.lv Liechtenstein Office for Communications (AK) www.ak.li Lithuania Radio Administration www.rrt.lt Luxembourg Institut Luxembourgeois des Télécommunications (ILT) www.etat.lu/ILT Netherlands Onafhankelijke Post en Telecommunicatie Autoriteit (OPTA) www.opta.nl Agentschap Telecom www.agentschap-telecom.nl Ministry of Economic Affairs www.ez.nl Norway Norwegian Post and Telecommunications Authority (NPT) www.npt.no Poland Urzad Regulacji Telekomunikacji (URT) www.urt.gov.pl Portugal Autoridad Nacional De Comunicaçòes (ICP-Anacom) www.anacom.pt Slovenia Agencija za telekomunikacije, radiodifuzijo in pošto www.atrp.si Spain Comisión del Mercado de las Telecomunicaçiones (CMT) www.cmt.es Sweden National Post and Telecom Agency (PTS) www.pts.se Switzerland Federal Office for Communications www.bakom.ch UK Office of Telecommunications (Oftel) www.oftel.gov.uk Postal Services Commission (Postcomm) www.postcomm.gov.uk/

Page 4 of the Omnitron Systems Technology Headset Microphone (HM-1000) user manual — 4. DESCRIPTION OF THE DEVICE
Page 4 · click to enlarge
Page 4

Radiocommunications Agency www.open.gov.uk/radiocom

Telecoms & Postal Regulatory Authorities in the Rest of the World Argentina Comisión Nacional de Comunicaciones (CNC) www.cnc.gov.ar Australia Department of Communications, Information Technology and the Arts www.dca.gov.au Brazil Anatel www.anatel.gov.br Canada Canadian Radio-television and Telecommunications Commission (CRTC) www.crtc.gc.ca Colombia Ministerio de Comunicaciones www.mincomunicaciones.gov.co Hong Kong Office of the Telecommunications Authority (OFTA) www.ofta.gov.hk Japan Ministry of Public Management, Home Affairs, Posts and Telecommunications www.soumu.go.jp Korea Ministry of Information and Communication (MIC) www.mic.go.kr Mexico Secretaría de Comunicaçiones y Transportes (SCT) www.sct.gob.mx Taiwan Ministry of Transportation and Communications (MOTC) www.motc.gov.tw/welcome.htm Thailand Post and Telegraph Department (PTD) www.ptd.go.th USA Federal Communications Commission (FCC) www.fcc.gov Postal Rate Commission (PRC) www.prc.gov

4. DESCRIPTION OF THE DEVICE

Omnitron Systems Technology Headset Microphone (HM-1000) — 4. DESCRIPTION OF THE DEVICE diagram (page 4)
Fig. 2
Show 8 more labels / short text on this page
(1) Housing · (4) Set-button · (7) LCD-display · (2) Battery compartment · (5) Down-button · (8) ON/OFF-switch · (3) Microphone grille · (6) Up-button
Page 5 of the Omnitron Systems Technology Headset Microphone (HM-1000) user manual — 5. PREPARATIONS
Page 5 · click to enlarge
Page 5

5. PREPARATIONS

Please refer to the explanations under Operating Determinations.

Switch the ON/OFF-button into the OFF-position.

Unscrew the microphone grille from the housing.

Open the battery cover by pressing the two clamps simultaneously.

If replacing the batteries, remove the old batteries from the battery compartment. Only replace complete battery-sets.

Remove empty batteries in accordance with the instructions of the manufacturer.

Insert the batteries (2 x 1.5 V Mignon batteries, AA) and make sure that the poles are correct.

Close the battery cover.

With the ON/OFF-switch, you can switch the device on and off. The battery symbol in the LCD-display indicates if the power supply is sufficient.

When the batteries are getting weaker, the battery symbol is getting smaller. In this case, the batteries have to be replaced.

Omnitron Systems Technology Headset Microphone (HM-1000) — 5. PREPARATIONS diagram (page 5)
Fig. 3

If the display does not show anything when switching on, there are either no batteries inserted or the poles are wrong.

If the microphone is not used, switch it off via the slide switch. If the device will not be used for a longer period of time, remove the batteries in order to avoid battery leakage.

In order to have a long battery life, you should only use alcaline batteries.

Pull the colour cap from the rear part of the housing.

Select the desired frequency via the mini switches: press and hold the Set-button for 3 seconds, the display shows "Freque". Press the Up or Down-button in order to select the desired frequency. Press the Set-button in order to store the settings.

If the signal-input at the receiver is too high, you can attenuate the signal output level via the Sensitivity-selection: press and hold the Set-button for 3 seconds, the display shows "Freque". Press the Set-button again and the display shows "Sensit". Press the Up or Down-button in order to select the desired sensitivity (0, - 10, -20, -30 dB). Press the Set-button in order to store the settings.

Press and hold the Up-button for 3 seconds in order to lock the microphone (LocOn). In this mode, the user cannot carry out undesired changes. In order to unlock the microphone, once more press and hold the Up- button for 3 seconds (LocOn)

Replace the desired colour cap to the rear part of the housing.

Page 6 of the Omnitron Systems Technology Headset Microphone (HM-1000) user manual — 7. TECHNICAL SPECIFICATIONS
Page 6 · click to enlarge
Page 6

6. CLEANING AND MAINTENANCE

Omnitron Systems Technology Headset Microphone (HM-1000) — 6. CLEANING AND MAINTENANCE diagram (page 6)
Fig. 4

We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use alcohol or solvents!

There are no servicable parts inside the device except for the batteries. Maintenance and service operations are only to be carried out by authorized dealers.

In order to replace the battery please refer to "Inserting/exchanging the batteries".

Should you need any spare parts, please use genuine parts.

Should you have further questions, please contact your dealer.

7. TECHNICAL SPECIFICATIONS

Type: Hand-held dynamic microphone Directivity pattern: Cardioid directivity pattern (uni-directional) Antenna: Built-in Sensitivity: 0, -10, -20, -30 dB Carrier frequency: UHF 790 - 814 MHz Modulation: FM Frequency stability: +/- 0,005 % T.H.D.: < 1 % at 1 KHz Tone signal: 32.768 KHz Frequency response: 50 - 18,000 Hz S/N-ratio: 60 dB Maximum deviation: +/- 48,000 Hz Sensitivity-selection: 0, -10, -20, -30 dB RF power output: 10 mW max. Coverage: 100 m (with line-of-sight) Power supply: 2 x 1.5 V Mignon batteries (type AA) Current consumption: approx. 100 mA Battery life: approx. 8 hours Dimensions: 40 x 260 mm Weight: 400 g

Please noteEvery information is subject to change without prior notice. 13.01.2005 ©
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Omnitron Systems Technology Headset Microphone (HM-1000)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Omnitron Systems Technology Headset Microphone (HM-1000)

Be the first to ask — other owners or our team will answer.

Original document

Omnitron Systems Technology Headset Microphone (HM-1000) manual PDF

21 pages·338 KB·Media Converter·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…