1.0 OVERVIEW This document describes the installation and configuration of the iConverter 10/100M standalone Network Interface Device and plug-in modules. The difference between the module types are indicated using the following legend throughout this User Manual:
1.1 GENERAL DESCRIPTION The Omnitron iConverter®10/100M is a carrier-class media converter and a Network Interface Device (NID) that provides 10BASE-T or 100BASE-TX (10/100) to 100BASE-FX Fiber media conversion with integrated management. The 10/100M conforms to Ethernet in the First Mile (EFM) fiber standards to support Fiber-to-the-X (FTTX) Metropolitan access and Enterprise LAN networks. 10/100M media converters are used to provide managed copper demarcation points at the customer premises and network edge, offering service provisioning functions, such as, Quality of Service and Bandwidth Control (rate-limiting) capabilities. The IP-based remote management of the 10/100M can be accessed by Omnitron’s NetOutlook® SNMP Network Management Software, third-party SNMP clients and Telnet. The management IP address is configured manually or as a DHCP client in the configuration menu. IP-less remote management is supported via 802.3ah OAM or Secure OAM protocol. A menu-driven CLI is accessible via Telnet, serial console port, or a modem connection to the serial console port.
This manual provides information on the installation and configuration of the module using the command line interface (serial console). For ongoing network management, Omnitron Systems recommends NetOutlook, an SNMP-based Network Management Software. NetOutlook provides an efficient, user-friendly way to configure, monitor and manage devices installed on a single network or on a series of networks by providing an intuitive graphical display with real-time status and alarm (trap) information. The user can easily manage iConverter equipment on a large Enterprise network or Metropolitan Area network (MAN) from a single location without the need of additional resources.
The firmware of the Network Management Module (NMM) and NetOutlook must be the same or greater than the firmware on the 10/100M for the module to be managed.

2.1 OVERVIEW The front panel of the 10/100M provides access to the management (serial console), UTP and fiber ports. The fiber port will vary depending on the connector type; ST, SC, MT-RJ, LC or SFP supporting 100BASE-FX transceivers. The plug-in module features two additional Ethernet ports for connectivity via the chassis backplane.

The 10/100M features a Serial RS-232 Console Port (aka Craft Interface) which can be connected to a computer for initial setup and configuration. The Serial Console Port is accessed through the mini DIN-6 female DCE interface. Connect the interface to a computer’s DB-9 serial port using the mini DIN-6 male to DB-9 female cable adapter (Part # 8082-0), which is included with the 10/100M. An optional DB-9 male to female straight-through serial cable is available for extension (Part # 8081-3).
The UTP Ethernet port supports 10BASE-T and 100BASE-TX protocols, auto-negotiation and manual forced modes for half and full duplex. The UTP port can be enabled or disabled via network management. A port disabled with the Port Access Control feature will still connect and allow 802.3ah OAM or IP-less (secure) OAM communication, but blocks normal data traffic. The fiber interface supports the 100BASE-FX protocol. The fiber interface always operates in manual mode and supports half or full duplex operation. The fiber port can be enabled or disabled via network management. A port disabled with the Port Access Control feature will still connect and allow 802.3ah OAM or IP-less (secure) OAM communication, but blocks normal data traffic.
The plug-in module supports two additional 10/100Mbps Ethernet Backplane Ports. The Backplane Ports A and B allow Ethernet data connectivity between adjacent modules in an iConverter chassis. The two backplane ports can be disabled or enabled via a DIP-switch or network management. The iConverter 19-Module, 5-Module, 2-Module and 1-Module Redundant Chassis backplanes provide ethernet data connectivity between adjacent slots or ports. The A and B backplane ports connect the slots as illustrated.





3.0 INSTALLATION PROCEDURE

The 10/100M plug-in module has two board-mounted DIP-switches. The standalone unit has one bank of DIP-switches. The locations of the DIP-switches are illustrated below.


3.2.1 Board-Mounted Bank 1 Settings
DIP-switch Bank 1 is available on both the plug-in and standalone modules. The table indicates the position of the switch; Left/Down or Right/Up. As indicated in the DIP-switch location diagram, Left and Right refers to the plug-in module and Down and Up refers to the standalone module.
3.2.1.1 SW1 - Pause Disable/Enable “Off/On” When a port is operating in auto-negotiation, its Pause operation mode is determined by the Pause capability advertised during auto-negotiation between itself and the link partner. The port advertises its Pause capability during auto-negotiation based on the Pause Disable/Enable DIP-switch setting. Setting the Pause DIP-switch to
(Left/Right) · (Up/Down)

the “Off” position (factory default) forces the port to negotiate to No Pause mode with its link partner. Setting the Pause DIP-switch to the “On” position allows the port to negotiate to Symmetrical Pause, or No Pause mode with its link partner. When a port is operating in Manual mode, its Pause operation mode is based on the Pause Disable/Enable DIP-switch setting. Setting the Pause DIP-switch to the “Off” position (factory default) forces the port to operate in No Pause mode. Setting the Pause DIP-switch to the “On” position allows the port to operate in Symmetrical Pause mode.
3.2.1.2 SW2 - Fiber Full/Half-Duplex “FDX/HDX” When the DIP-switch is in the Full Duplex “FDX” position (factory default), the fiber port will facilitate a connection that supports Full-Duplex operation. Setting this DIP-switch to Half-Duplex “HDX” facilitates a connection that supports only Half-Duplex.
3.2.1.3 SW3 - UTP Auto/Manual Negotiate “AN/Man” When the DIP-switch is in the UTP auto-negotiate “AN” position (factory default), the UTP port automatically determines the speed and duplex mode of the connecting UTP device. If the connecting UTP device cannot provide the proper signal to indicate its own mode of operation, this DIP-switch should be set to the UTP Manual mode “Man” position. Manual mode requires manually configuring the UTP port to match the speed and the duplex mode of the connecting UTP device using the “10/100” and UTP “FDX/HDX” DIP-switches. Refer to the table below for a detailed explanation.
3.2.1.4 SW4 - UTP 10/100Mbps “10/100” When the UTP “AN/Man” DIP-switch (described above) is in the manual “Man” position, the “10/100" DIP-switch determines the speed of operation for the UTP port. Setting the “10/100” DIP-switch to UTP

100Mbps “100” position (factory default) forces the UTP port to operate at 100Mbps. Setting this DIP-switch to UTP 10Mbps “10” position forces the UTP port to operate at 10Mbps. Adjust the “10/100” DIP-switch to match the speed of the connecting UTP device. When the UTP “AN/Man” DIP-switch is in the auto-negotiate “AN” position and the UTP 10/100 DIP-switch is in the “100” position, the UTP port auto-negotiates to 100Mbps or 10Mbps. When in the “10” position, the UTP port only operates at 10Mbps. Refer to the table above for a detailed explanation.
3.2.1.5 SW5 - UTP Full/Half Duplex “FDX/HDX” When the UTP “AN/Man” DIP-switch is in the manual “Man” position, the UTP Full/Half-Duplex “FDX/HDX” DIP-switch determines the duplex operation mode of the UTP port. Setting the UTP Full/Half-Duplex DIP-switch to UTP Full-Duplex “FDX” position (factory default) forces the UTP port to operate in Full-Duplex. Setting this DIP-switch to UTP Half-Duplex “HDX” forces the UTP port to operate in Half-Duplex. Adjust the UTP Half/Full-Duplex DIP-switch to match the duplex mode of the connecting UTP device. When the UTP “AN/Man” DIP-switch is in the auto-negotiate “AN” position, and the UTP Full/Half-Duplex DIP-switch is in the Full-Duplex “FDX” position, the UTP port auto-negotiates to Full or Half-Duplex. When in the Half-Duplex “HDX” position, the UTP port functions only in Half-Duplex for the speed selected. Refer to the table on the previous page for a detailed explanation.
3.2.1.6 SW6, SW7, SW8 - Link Modes These three DIP-switches configure the link mode settings. The following table details possible Link Mode DIP-switch configurations.

DIP-switch Bank 2 is only available on the plug-in module.
3.2.2.1 SW1 - Backplane Port A Enabled “A-DS/A-EN” When the DIP-switch is in the Left “A-DS” position (factory default), Backplane Port A of the 10/100M is isolated from the chassis Backplane. When the DIP-switch is in the Right “A-EN” position, Backplane Port A of the 10/100M is enabled. This port allows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Port A. See the backplane illustrations in Section 2.1.3.
3.2.2.2 SW2 - Backplane Port B Enabled “B-DS/B-EN” When the DIP-switch is in the Left “B-DS” position (factory default), Backplane Port B is isolated from the chassis Backplane. When the DIP-switch is in the Right “B-EN” position, Backplane Port B is enabled. This port allows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Port B. See the backplane illustrations in Section 2.1.3.
3.2.2.3 SW4 - Master/Slave Auto-Select and Slave-Only “M/SL / SL When multiple management modules such as the NMM and the 10/100M (or multiple self-managed modules such as the 10/100M) are installed in the same chassis, only one management module can act as the chassis master. The master management module has the ability to make changes to the settings of the other modules in the chassis, while the slave management modules cannot make the changes. If an NMM is installed in the chassis, the NMM will always be the master, otherwise the lowest slot number with a management module installed will become chassis master. When this DIP-switch is in the Left “M/SL” position (factory default), the assignment of mastership is automatically negotiated by the installed management modules. To designate a specific management module as the master when no NMM is installed in the chassis, set the DIP-switch on the master module to the Left “M/SL” position, and set the other installed management modules’ DIP-switches to the Right “SL” position to enable Slave-Only mode. Only the chassis master can change configuration settings of other modules.
3.2.2.4 SW3, SW5, SW6, SW7, SW8 - Reserved These DIP-switches are for factory use only.

a. Carefully slide the module into an open slot in the chassis. Align the module with the installation guides and ensure that the module is firmly seated against the backplane. Secure the module by fastening the front panel thumbscrew (push in and turn clockwise to tighten) to the chassis front. Verify the “Pwr” LED is ON (indicating the chassis is powered).
a. The 10/100M standalone Network Interface Device (NID) is available in tabletop and wall-mounting models. For wall-mounting, attach the NID to a wall, backboard or other flat surfaces. For tabletop installations, place the unit on a flat level surface. Attach the rubber feet to the bottom of the NID to prevent the unit from sliding. Make sure the unit is placed in a safe, dry and secure location. To power the unit using the AC/DC adapter, connect the AC/DC adapter to the AC outlet. Then connect the barrel plug at the end of the wire on the AC/DC adapter to the 2.5mm DC barrel connector (center-positive) on the unit. Confirm that the unit has powered up properly by checking the power status LED located on the front of the unit. To power the unit using a DC power source, prepare a power cable using a two-conductor insulated wire (not supplied) with a 14 AWG gauge minimum. Cut the power cable to the length required. Strip approximately 3/8 of an inch of insulation from the power cable wires. Connect the power cables to the 10/100M standalone unit by fastening the stripped ends to the DC power connector. Connect the power wires to the DC power source. The Power LED should indicate the presence of power.
b. When using a 10/100M SFP model, insert the SFP Fiber transceiver into the Port 1 SFP receptacle on the 10/100M.
NOTE: The release latch of the SFP Fiber transceiver must be in the closed (up) position before insertion. c. Connect the UTP port via a Category 5 or better cable to a 10BASE-T or 100BASE-TX Ethernet device. d. Connect the appropriate multimode or single-mode fiber cable to the fiber port of the installed module. It is important to ensure that the transmit (Tx) is attached to the receive side of the device at the other end and the receive (Rx) is attached to the transmit side. Single-fiber (SF) media converter models operate in pairs. The Tx wavelength must match the Rx wavelength at the other end and the Rx wavelength must match the Tx wavelength at the other end.

To configure, attach the 10/100M to a DB-9 serial (RS-232) equipped computer with terminal emulation software such as HyperTerminal. The 10/100M Serial Console Port (DCE) is a mini DIN-6 female connector which can be changed to a DB-9 connector with the included adapter (Part #8082-0). Attach the ends of a serial cable to the serial port of the PC and the Serial Console Port of the 10/100M. This is a standard asynchronous serial interface. The pin-outs are illustrated below.

Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window. Set the PC’s serial port to the following: Bits Per Second: 57,600 Stop Bits: 1 Data Bits: 8 Parity: NONE Hardware Flow Control: NONE
Power the chassis containing the 10/100M module and press to bring up a command line prompt on the attached PC.
The module is configured with the following defaults: IP IP Address: 192.168.1.220 IP Subnet Mask: 255.255.255.0 Passwords Serial: No password assigned FTP: No password assigned Telnet: public
SNMPv3 Parameters User 1 name (read only): guest User 2 name (read/write): admin User 1 Privacy pwd: publicguest User 1 Authen pwd: publicguest User 2 Privacy pwd: privateadmin User 2 Authen pwd: privateadmin

The Management Options screen will be displayed.
Management Options iConverter, Serial Agent
Management Module Preferences 3: IP and Control Preferences 4: SNMP Preferences 5: Abandon Preference Changes 6: Save Preference Changes 7: Restore to Factory Defaults 8: Restart Management Module 9: Other Networking Features
IP Address = 192.168.1.220 Chassis Number = 1
Enter Choice, (H)elp, E(x)it >
A new 10/100M module does not have a password, and will skip the Password Entry screen and go straight to the Management Options screen. If a password has been set, the Password Entry screen will be displayed. Type the password and press , the 10/100M will respond with the Management Options screen.
Omnitron Systems Technology, Inc. iConverter, Serial Agent Copyright 2001-2007 OST, Inc. Password Entry
Omnitron Systems Technology Technical Support: (949) 250-6510 140 Technology #500 Sales/Products: (800) 675-8410 Irvine, CA 92618 On the web at: www.omnitron-systems.com
IP Address 192.168.1.220 MAC 00:00:00:00:00:00
[xxxxxxxx] Please enter the password >

3.4.1 Setting IP and Control Preferences An IP address is required for the SNMP manager to address the 10/100M. The factory default setting is 192.168.1.220. The IP address can be configured manually or automatically as a DHCP client.
3.4.1.1 Setting IP Parameters Manually To manually configure the IP address and control parameters, select 3 from the Management Options screen. The IP and Control Preferences screen will appear.
IP and Control Preferences Screen iConverter, Serial Agent
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To configure the IP address of the 10/100M, select 1 at the IP and Control Preferences screen, and press . Backspace over the existing value, type the new value (in x.x.x.x format), and press . To configure the subnet mask of the 10/100M, select 2 at the IP and Control Preferences screen, and press . Backspace over the existing value, type the new value (in x.x.x.x format), and press . To configure the gateway of the 10/100M, select 3 at the IP and Control Preferences screen, and press . Backspace over the existing value, type the new value (in x.x.x.x format), and press . To save the new values, select 0 and press to return to the Management Options screen, then select 6 and press to Save Preference Changes.
3.4.1.2 Setting IP Parameters as DHCP Client To configure the IP automatically as a DHCP client, select 9 from the Management Options screen. The Other Networking Features screen will appear.

Management Options iConverter, Serial Agent
Management Module Preferences 3: IP and Control Preferences 4: SNMP Preferences 5: Abandon Preference Changes 6: Save Preference Changes 7: Restore to Factory Defaults 8: Restart Management Module 9: Other Networking Features
IP Address = 192.168.1.220 Chassis Number = 1
Enter Choice, (H)elp, E(x)it > 9
Other Networking Features Screen iConverter, Serial Agent
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To enable DHCP client, select 1 at the Other Networking Features screen and follow the screen prompts to enable DHCP. To save the new values, select 0 and press to return to the Management Options screen, then select 6 and press to Save Preference Changes.
3.4.1.3 Setting the Chassis Number and Name A Chassis Name, or sysName, can be assigned for identification of the 10/100M in the SNMP client. The name can be any 1-32 character alphanumeric string. The Chassis Number can remain as 1 (factory default) when the 10/100M is installed without an iConverter NMM in the same chassis. When the 10/100M is installed in the same chassis as an NMM, then the 10/100M must be set to the Chassis Number of the NMM. To set the Chassis Number, select 4 at the IP and Control Preferences screen, press <ENTER> and follow the instructions to enter the chassis number. To set the Chassis Name, select 5 at the IP and Control Preferences screen, press <ENTER> and follow the instructions to enter the chassis name.

IP and Control Preferences Screen iConverter, Serial Agent
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.
3.4.1.4 Setting 10/100M Passwords The 10/100M is shipped from the factory without password protection on the Serial Console Port. It is highly recommended that the network administrator set a password in order to prevent unauthorized access to the unit. The password can be any 1-32 character alphanumeric string. The 10/100M is shipped from the factory with Telnet enabled and FTP disabled. From the IP and Control Preferences screen, select 6 to enable or disable Telnet, and select 7 to enable or disable FTP. To set the password for Telnet access, select 9 at the IP and Control Preferences screen, press and then follow the screen prompts to enter and verify the password. The default password for Telnet access is “public”. To set the password for FTP access, select 10 at the IP and Control Preferences screen, press and then follow the screen prompts to enter and verify the password. To set the password for serial access, select 11 at the IP and Control Preferences screen, press and then follow the screen prompts to enter and verify the password.

IP and Control Preferences Screen iConverter, Serial Agent
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To save the new values, select 0 and press to return to the Management Options screen, then select 6 and press to Save Preference Changes.
3.4.2 Setting SNMP Preferences To set the SNMP Preferences for the 10/100M module, select 4 from the Management Options screen, press to enter the SNMP Preferences screen.
Management Options iConverter, Serial Agent
Management Module Preferences 3: IP and Control Preferences 4: SNMP Preferences 5: Abandon Preference Changes 6: Save Preference Changes 7: Restore to Factory Defaults 8: Restart Management Module 9: Other Networking Features
IP Address = 192.168.1.220 Chassis Number = 1
Enter Choice, (H)elp, E(x)it > 4

SNMP Preferences Screen iConverter, Serial Agent
Chassis Number = 1 SNMP Engine ID 80001CAE03000687003B19
SNMP v1/v2c 4: Read Community ***** 5: Write Community ***** 6: Agent Enabled
SNMP V3 7: Agent Enabled 8: User 1 name (read only) guest 9: User 2 name (read/write) admin 10: User 1 Security noAuthNoPriv 13: User 2 Security noAuthNoPriv 11: User 1 Privacy pwd ***** 14: User 2 Privacy pwd ***** 12: User 1 Authen. pwd ***** 15: User 2 Authen. pwd *****
Traps Hosts 16: Address 1 255.255.255.255 20: Address 5 255.255.255.255 17: Address 2 255.255.255.255 21: Address 6 255.255.255.255 18: Address 3 255.255.255.255 22: Address 7 255.255.255.255 19: Address 4 255.255.255.255 23: Address 8 255.255.255.255
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
3.4.2.1 Setting SNMPv1/v2c Read and Write Community Names The 10/100M is shipped from the factory with the SNMP agent enabled with the default SNMP Read and Write Community name as “public”. See Section 3.4 for all factory default settings. The SNMP Read Community Name is necessary for reading data from the 10/100M. The name can be any 1-32 character alphanumeric string. To set the SNMP Read Community Name, select 4 at the SNMP Preferences screen, press and then follow the screen prompts. The SNMP Write Community Name is necessary for writing data to the 10/100M. The name can be any 1-32 character alphanumeric string. To set the SNMP Write Community Name, select 5 at the SNMP Preferences screen, press and then follow the screen prompts. To save the new values, select 0 and press to return to the Management Options screen, then select 6 and press to Save Preference Changes.
3.4.2.2 Setting SNMPv3 Parameters SNMPv3 implements a security model that provides for message integrity, authentication, and encryption. Authentication for SNMPv3 is provided through a unique User Name and Authentication Password for each access level. Two access levels or accounts are available; Read-Only Level (User 1) and Read and Write Level (User 2). User 1 is allowed to request information from the module. User 2 is allowed to request information from and set configuration to the module. To set the User 1 name, select 8 at the SNMP Preferences screen, press and then follow the screen prompts. To set the User 2 name, select 9 at the SNMP Preferences screen, press and then follow the screen prompts. The 10/100M is shipped with default values pre-assigned. See Section 3.4 for all factory default settings. The module supports the three levels of Authentication and Encryption (Security Levels) for User 1 and User 2; noAuthNoPriv, authNoPriv and authPriv. noAuthNoPriv uses username for authentication,

authNoPriv provides authentication based on the HMAC-MD5 algorithm and authPriv provides DES 56-bit encryption based on the HMAC-MD5 algorithm. To set User 1 security, select 10 at the SNMP Preferences screen, press and then follow the screen prompts. To set the User 2 security, select 13 at the SNMP Preferences screen, press and then follow the screen prompts. To set User 1 privacy password, select 11 at the SNMP Preferences screen, press and then follow the screen prompts. To set the User 2 privacy password, select 14 at the SNMP Preferences screen, press and then follow the screen prompts. To set User 1 authentication password, select 12 at the SNMP Preferences screen, press and then follow the screen prompts. To set the User 2 authentication password, select 15 at the SNMP Preferences screen, press and then follow the screen prompts. To save the new values, select 0 and press to return to the Management Options screen, then select 6 and press to Save Preference Changes. Community name and User name can be any 1-32 character alphanumeric string Authentication Password and Privacy Password can be any 1-16 character alphanumeric string.
3.4.2.3 Setting the SNMP Trap IP Host Addresses SNMP traps are used to report events that occur during the operation of a network, and may require the attention of the network administrator. The 10/100M is capable of sending SNMP traps to up to eight different SNMP Traphosts. To enter the IP address of the first Traphost Address, select 4 at the Management Options screen to access the SNMP Preferences screen. Select 16 at the SNMP Preferences screen and press . Then backspace over the existing value, type the new value (in x.x.x.x format), and press . To enter the IP addresses of additional trap-receiving Traphost Addresses, repeat this process for Traphost Addresses 2-8 (menu options 17-23). To save the new values, select 0 and press to return to the Management Options screen, then select 6 and press to Save Preference Changes.
3.4.2.4 Enabling/Disabling SNMPv1/v2c Agent To disable/enable SNMPv1/v2c agent, select 4 at the Management Options screen to access the SNMP Preferences screen. Select option 6 to disable/enable SNMPv1/v2c agent. When disabled, the module will not respond to any requests via the SNMPv1/v2c protocol.
3.4.2.5 Enabling/Disabling SNMPv3 Agent To disable/enable SNMPv3 agent, select 4 at the Management Options screen to access the SNMP Preferences screen. Select option 7 to disable/enable SNMPv3 agent. When disabled, the module will not respond to any requests via the SNMPv3 protocol.

3.4.3 Management Processor VLAN Support The 10/100M Management Processor can independently transmit and receive Management Data with an IEEE 802.1Q tag. To enable and configure this feature, type 9 from the Management Options screen to access the Other Networking Features screen.
Management Options iConverter, Serial Agent
Management Module Preferences 3: IP and Control Preferences 4: SNMP Preferences 5: Abandon Preference Changes 6: Save Preference Changes 7: Restore to Factory Defaults 8: Restart Management Module 9: Other Networking Features
IP Address = 192.168.1.220 Chassis Number = 1
Enter Choice, (H)elp, E(x)it > 9
Other Networking Features Screen iConverter, Serial Agent
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To configure the VLAN management ID, select option 7. To configure the priority setting for the VLAN management channel, select option 8. To enable or disable VLAN management support, select option 6. Once VLAN support is enabled, IP management support will only be accessible using the configured VLAN ID. To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.
3.4.4 Enabling/Disabling Soft-switch Reload The Soft-switch Reload function controls the configurations of the 10/100M and other iConverter modules managed by the 10/100M following a power up. When the Soft-switch Reload is disabled, the configurations of the 10/100M and the other managed modules

(non-management modules) are determined by their hardware DIP-switch settings following a return of power. When the Soft-switch Reload is enabled, the configurations of the 10/100M and the other managed modules are determined by the previous software settings stored in the FLASH memory of the 10/100M following a return of power. Each of the hardware DIP-switch settings on the module are ignored until a change is made to the DIP-switch, then the hardware settings will take effect. To set the Soft-switch Reload function, select 8 at the IP and Control Preferences screen, press and then follow the screen prompts to change the setting.
IP and Control Preferences Screen iConverter, Serial Agent
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes.

3.4.5 Access the 10/100M Remotely Remote access to the 10/100M is provided via SNMP, Telnet, FTP or an external serial modem connected to the Serial Console Port.
3.4.5.1 Accessing the 10/100M via NetOutlook (SNMP) The 10/100M module can be remotely accessed by SNMP-client software such as NetOutlook or third- party SNMP management software. See Setting SNMP Preferences Section 3.4.2, on how to configure the required parameters.

3.4.5.2 Accessing the 10/100M via Telnet The 10/100M is shipped from the factory with Telnet enabled. The default Telnet password is “public”. It is highly recommended that the network administrator set a new Telnet password in order to prevent unauthorized access to the unit. Telnet configuration parameters are available from the IP and Control Preferences screen, option 6.

IP and Control Preferences Screen iConverter, Serial Agent
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >6 Disable TELNET (Y/N)?>
To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then select 6 and press <ENTER> to Save Preference Changes. The 10/100M may be accessed and configured via Telnet using any standard Telnet client. Only one Telnet session can be active at a time. An inactive Telnet session terminates automatically after 5 minutes.
3.4.5.3 Updating the 10/100M Firmware via the Serial Console Port To update the 10/100M firmware from the Serial Console Port, select 10 at the Management Options screen, press . The 10/100M will display the following:
Management Options iConverter, Serial Agent
Management Module Preferences 3: IP and Control Preferences 4: SNMP Preferences 5: Abandon Preference Changes 6: Save Preference Changes 7: Restore to Factory Defaults 8: Restart Management Module 9: Other Networking Features
IP Address = 192.168.1.220 Chassis Number = 1
Enter Choice, (H)elp, E(x)it > 10 UPDATE: Are you sure? (Y/N) > Y Please Xmodem file now:
From the terminal program, use the Xmodem protocol to send the new 10100M-xxx.bin firmware file to the 10/100M module (where xxx represents the release level of the software). Once the file transfer begins, the data uploads to the 10/100M. The process takes about five minutes over a serial connection.

When the upload is complete, the 10/100M displays the update status and then automatically restarts with the newly loaded firmware.
3.4.5.4 Updating the 10/100M Firmware via FTP Using an FTP application, upload the new firmware into the FTP root directory of the 10/100M. When the file transfer is complete, the 10/100M verifies the file and then automatically restarts with the newly loaded firmware. For detailed instructions on updating the management modules and other modules in the same chassis via FTP, download the application note “iConverter Management: Updating Modules via FTP” available on Omnitron’s web page: http://www.omnitron-systems.com/downloads.php See Setting 10/100M Passwords Section 3.4.1.4, on how to configure FTP.
Once the module has been installed and configured, per Sections 3.2 - 3.4, verify the module is operational by viewing the status of the LED indicators. The table below provides a description for each LED indicator. The Power LED indicates the module is receiving power from the chassis or power cord. The plug-in modules has an LED indicator for each available power supply in the chassis (the 19-Module Chassis has three, the 5-Module Chassis has two). The Fiber Optic “FO” LED indicates the fiber optic connection between the modules has been established. A blinking LED indicates the presence of data. The UTP “10/100” LED indicates the module has established a connection across its UTP port. A blinking LED indicates the presence of data. Refer to Section 6.0, Troubleshooting Guide, for help in determining possible fault conditions.
"Legend" Color Off State On / Blinking State On / Blinking State
Power "Pwr" Amber No power On: Module has power On: Module has power
Power Supply Status #X Amber Chassis Power
Not available on standalone
from installed Power Supply #X
100Mbps Fiber Optics "FO" Green No Fiber Link On: Fiber link is active Blinking: Fiber Data Activity
Chassis Management Master/Slave "BP"
Green Chassis Slave Mode
Not available on standalone
UTP port 10Mbps "10" Green 10Mbps not active On: 10Mbps UTP link is active Blinking: UTP Data Activity
UTP port 100Mbps "100" Green 100Mbps not active On: 100Mbps UTP link is active Blinking: UTP Data Activity
Half-Duplex when any UTP link is active
UTP port Full- Duplex "FDX" Green
Full-Duplex when any UTP link is active
Full-Duplex when any UTP link is active
LED Function · Supply not installed

4.1 OVERVIEW The 10/100M has module parameters that require configuration depending on the application. The Module configuration screen is accessible by selecting the module slot number from the Chassis View screen. To access the Module configuration menu, select 1 at the Management Options screen, press . The Chassis Selection screen will be displayed. From the Chassis Selection screen, select the chassis number where the 10/100M module is installed. NOTE: Module configuration is also available using NetOutlook.
Chassis Selection iConverter, Serial Agent
Number Chassis Name 1 NMM 2 Not Available 3 Not Available 4 Not Available 5 Not Available 6 Not Available 7 Not Available 8 Not Available 9 Not Available 10 Not Available 11 Not Available 12 Not Available 13 Not Available 14 Not Available 15 Not Available 16 Not Available 17 Not Available 18 Not Available 19 Not Available Connected to Chassis Number 1
Chassis Number(1-19), Management Options(0), (H)elp, E(x)it > 1
By selecting Chassis Number 1, from the Chassis Selection screen, the Chassis View screen will be displayed.

Chassis View 19 Slot iConverter, Serial Agent
Chassis Number = 1
Slot Model Type | Slot Model Type 1 8000-0 NMM | 16 N/A 2 8903-1 10/100M | 17 N/A 3 8911-1 10/100M | 18 N/A 4 N/A | 19 N/A 5 8919-0 10/100M | 20 N/A 6 N/A | 21 8200-9 Power Supply 7 N/A | 22 N/A 8 N/A | 9 N/A | 10 N/A | 11 N/A | 12 N/A | 13 N/A | 14 N/A | 15 N/A |
Module to View(1-22), Chassis Selection(0), (R)eset, (H)elp, E(x)it > 5
Chassis View 1 Slot iConverter, Serial Agent
Chassis Number = 1
Slot Model Type Module Identifier 1 8919-0 10/100M
Module to View(1), Management Options(0), (R)eset, (H)elp, E(x)it >1
From the Chassis View menu, select the desired module (select 1 or 5), press . The Module configuration screen will be displayed.

Module - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Switch ON Condition OFF Condition H/W Actual Slot Number = 1 1: Pause Enabled Pause Disabled Off Off Model Number = 8919-0 2: Fiber HDX Fiber FDX Off Off 3: UTP Manual UTP Auto-Neg Off Off Serial Number = xxxxxxxx 4: UTP 10 Mbps UTP 100 Mbps Off Off Manufacturing Date = xxxxxxxx 5: UTP HDX UTP FDX Off Off Product Revision = x 6: Link Propagate Link Segment Off Off Software Revision = xx 7: Remote Fault Normal Off Off 8: Symm Fault Det Normal Off Off LED 9: BP A Enabled BP A Disabled On On 1: Power = On 10: BP B Enabled BP B Disabled On On 2: Power Supply 1 = Off 11: Not Available 3: Power Supply 2 = Off 12: Slave Only Master/Slave Off Off 4: Power Supply 3 = Off 13: Not Available 5: Fiber Link = Off 14: Not Available 6: BP Master = On 15: Not Available 7: UTP 10 Link = Off 16: Not Available 8: UTP 100 Link = Off OAM settings: 9: UTP FDX = Off 17: IP Protocol State On 18: Management Mode Secure OAM Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl >
The Module configuration screen provides general information concerning the configuration and status of the module. The screen displays the model and serial numbers, hardware and software revisions, as well as the condition of the LEDs and DIP-switches. The DIP-switches can be re-configured (options 1 - 10, 12) without removing the module from the chassis. Select the appropriate option to change the DIP-switch setting. Selecting DIP-switch options 1 - 10 and 12, will cause the selection to change states under the ‘Actual’ heading.

4.2 MODULE MANAGEMENT MODE From the Module configuration screen, the management mode can be changed. Select option 18 to change the mode. The management mode options will be displayed.
Module - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Switch ON Condition OFF Condition H/W Actual Slot Number = 1 1: Pause Enabled Pause Disabled Off Off Model Number = 8919-0 2: Fiber HDX Fiber FDX Off Off 3: UTP Manual UTP Auto-Neg Off Off Serial Number = xxxxxxxx 4: UTP 10 Mbps UTP 100 Mbps Off Off Manufacturing Date = xxxxxxxx 5: UTP HDX UTP FDX Off Off Product Revision = x 6: Link Propagate Link Segment Off Off Software Revision = xx 7: Remote Fault Normal Off Off 8: Symm Fault Det Normal Off Off LED 9: BP A Enabled BP A Disabled On On 1: Power = On 10: BP B Enabled BP B Disabled On On 2: Power Supply 1 = Off 11: Not Available 3: Power Supply 2 = Off 12: Slave Only Master/Slave Off Off 4: Power Supply 3 = Off 13: Not Available 5: Fiber Link = Off 14: Not Available 6: BP Master = On 15: Not Available 7: UTP 10 Link = Off 16: Not Available 8: UTP 100 Link = Off OAM settings: 9: UTP FDX = Off 17: IP Protocol State On 18: Management Mode Secure OAM Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl > Mode (1=OAM Off, 2=Auto Secure OAM, 3=Auto ah OAM, 4=Secure OAM, 5=ah OAM): 3
The 10/100M module supports several management options. Option 18 configures how the module will communicate to its remote partner. ‘Auto Secure OAM’ (option 2) and ‘Secure OAM’ (option 4) uses Omnitron’s proprietary secure encrypted management channel. ‘Auto Secure OAM’ will force the remote partner to communicate using the Secure OAM protocol while ‘Secure OAM’ will only attempt to communicate with the remote partner over the secure protocol. The management channel can support IP or IP-less connectivity based on the configuration of the ‘IP Protocol State’, option 17. ‘Auto ah OAM’ (option 3) and ‘ah OAM’ (option 5)’ conforms to the IEEE 802.3ah specification. ‘Auto ah OAM’ will force the remote partner to communicate using the ah OAM protocol while ‘ah OAM’ will only attempt to communicate with the remote partner over the ah protocol. This option provides an industry standard method of fault detection and monitoring. The management channel supports both IP and IP-less connectivity based on the configuration, option 17 and 18.

4.3 PORT CONFIGURATION The Port configuration screen provides access to the port level configuration parameters, such as, Port Access, Bandwidth Control, SFP information, 802.3ah, Port VLANs, Tagged VLANs and cNode Loopback. To access the Port configuration screen, select C from the Module configuration screen and press . The Port configuration screen will appear.
Module - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Port VLAN Path Setup Slot Number = 11 Model Number = 8919-0 11: Fiber to UTP Enable On 12: Fiber to BP A Enable On Port Access Control Setup 13: Fiber to BP B Enable On 14: UTP to BP A Enable On 1: Fiber Enable On 15: UTP to BP B Enable On 2: UTP Enable On 16: BP A to BP B Enable On 17: Fiber to Mngmnt Enable On Enhanced Features 18: UTP to Mngmnt Enable On 19: BP A to Mngmnt Enable On 3: 802.1Q Processing Enable Off 20: BP B to Mngmnt Enable On 4: Configure Tag VLAN Control 5: Configure VLAN Membership Bandwidth Control 6: Save TAG VLAN parameters 7: Configure 802.3ah parameters 21: Ingress rate Fiber No Limit 8: Configure 802.3ah events 22: Egress rate Fiber No Limit 9: SFP Information 23: Ingress rate UTP No Limit 10: cNode Loopback 24: Egress rate UTP No Limit
Enter Choice, Previous Screen(0), (H)elp, E(x)it >
Module - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Port VLAN Path Setup Slot Number = 11 Model Number = 8919-0 11: Port1 to Port2 Enable On 12: Port1 to Mngmnt Enable On Port Access Control Setup 13: Port2 to Mngmnt Enable On 1: Fiber Enable On Bandwidth Control 2: UTP Enable On 14: Ingress rate Fiber No Limit Enhanced Features 15: Egress rate Fiber No Limit 16: Ingress rate UTP No Limit 3: 802.1Q Processing Enable Off 17: Egress rate UTP No Limit 4: Configure Tag VLAN Control 5: Configure VLAN Membership 6: Save TAG VLAN parameters 7: Configure 802.3ah parameters 8: Configure 802.3ah events 9: SFP Information 10: cNode Loopback
Enter Choice, Previous Screen(0), (H)elp, E(x)it >

4.3.1 Port Access The Port Access option allows the ports to be disabled/enabled while maintaining the port configuration and network link To configure Port Access, select option 1 for the Fiber port and option 2 for the UTP port from the Port configuration screen.
4.3.2 Bandwidth Control The 10/100M Bandwidth Control is accessed by selecting options 21 - 24 or 14 - 17 depending on the module type; plug-in or standalone. The 10/100M provides separate ingress and egress rate control on each port. Ingress values will be displayed when the option is selected. Values of 128Kbps, 256Kbps, 512Kbps, 1Mbps, 2Mbps, 4Mbps, 8Mbps and Full bandwidth are available. Egress values will be displayed when the option is selected. Values of 128Kbps, 256Kbps, 512Kbps, 1Mbps, 2Mbps, 4Mbps, 8Mbps and Full bandwidth are available.
Module - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Port VLAN Path Setup Slot Number = 11 Model Number = 8919-0 11: Fiber to UTP Enable On 12: Fiber to BP A Enable On Port Access Control Setup 13: Fiber to BP B Enable On 14: UTP to BP A Enable On 1: Fiber Enable On 15: UTP to BP B Enable On 2: UTP Enable On 16: BP A to BP B Enable On 17: Fiber to Mngmnt Enable On Enhanced Features 18: UTP to Mngmnt Enable On 19: BP A to Mngmnt Enable On 3: 802.1Q Processing Enable Off 20: BP B to Mngmnt Enable On 4: Configure Tag VLAN Control 5: Configure VLAN Membership Bandwidth Control 6: Save TAG VLAN parameters 7: Configure 802.3ah parameters 21: Ingress rate Fiber No Limit 8: Configure 802.3ah events 22: Egress rate Fiber No Limit 9: SFP Information 23: Ingress rate UTP No Limit 10: cNode Loopback 24: Egress rate UTP No Limit
Enter Choice, Previous Screen(0), (H)elp, E(x)it >21 New Rate (0= No Limit, 1=128Kbps, 2=256Kbps, 3=512Kbps, 4=1Mbps, 5=2Mbps, 6=4Mbps, 7=8Mbps) > 0

4.3.3 SFP Information The 10/100M module installed with an SFP will provide general and specific information on the SFP. This information is best viewed with SNMP management software. The following is the information available:

SFP information can be obtained by selecting option 9 from the Port configuration screen.
SFP Information - iConverter 10/100M iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8919-0 Port = 1
Address A0 Page Contents =================================================== 00: 03 04 07 00 10 02 00 01 03 00 14 C8 10: 37 37 00 00 43 4F 52 45 54 45 4B 20 77..xxxxxxx 20: 20 00 43 54 2D 30 31 35 35 53 xxxxxxxx 30: 53 50 2D 4D 42 35 4C 44 30 05 1E 00 84 xxxxxxxxxxxx 40: 00 1A 00 00 41 31 36 37 45 43 35 30 A167EC500000 50: 36 20 20 20 30 35 31 32 30 37 20 20 68 90 01 A4 6 051207 h... 60: FF 70: FF 80: FF 90: FF A0: FF B0: FF C0: FF D0: FF E0: FF F0: FF
Enter Previous Screen(0), (n)ext page, (H)elp, E(x)it > n
SFP Information - iConverter 10/100M iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8919-0 Port = 1
Address A2 Page Contents =================================================== 00: 64 00 F6 00 5A 00 FB 00 8C A0 75 30 88 B8 79 18 d...Z u0..y. 10: 9C 40 03 E8 88 B8 07 D0 09 D0 00 FB 07 CB 01 3C .@ < 20: 18 A6 00 05 13 94 00 06 00 30: 00 40: 00 3F 80 00 01 00 00 00 ? 50: 01 00 00 00 01 00 00 00 01 00 AE 60: 24 A8 80 78 17 14 03 F0 00 02 F8 $..x 70: 00 40 00 00 00 40 00 .@...@ 80: FF 90: FF A0: FF B0: FF C0: FF D0: FF E0: FF F0: FF
Enter Previous Screen(0), (b) previous page, (H)elp, E(x)it >

4.3.4.2 Remote Status Section The Remote Status section displays the status of the ports of the 802.3ah enabled remote partner. These remote ports are connected to the Fiber and UTP ports of the local device. The remote partner is managed by the local device via the 802.3ah OAM channel. • Discovery State - Indicates the Discovery state (“Complete”, “In Process” or “Incomplete”) of the remote ports. If “Complete” is displayed, Discovery has been completed. If “In Process”, Discovery has been initiated but no response from the local device has yet been received by the remote partner. If “Incomplete”, Discovery is in process, but is not yet completed.

802.3ah Control - iConverter 10/100M iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8919-0 Port # = 1
Discovery State Incomplete Critical Event No Link Fault No Multiplexer State Unknown Parser Action Unknown Mode Unknown Supports Unknown OUI: Unknown
Enter, Previous Screen (0), (n)ext page, (H)elp, E(x)it >
To configure the 802.3ah parameters for the UTP port, type an n and press .
Remote Status

4.3.5 802.3ah Events 802.3ah events can be accessed by selecting options 8 from the Port configuration screen.
802.3ah Event - iConverter 10/100M iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8919-0
Port 1 1: Symbol Period Window 0 second < 0 symbols> 2: Symbol Period Threshold 0 symbols 3: Frame Window 0 seconds 4: Frame Threshold 0 frames 5: Frame Period Window 0 second < 0 frames> 6: Frame Period Threshold 0 frames 7: Frame Seconds Summary Window 0 seconds 8: Frame Seconds Summary Threshold 0 seconds UTP 9: Symbol Period Window 0 second < 0 symbols> 10: Symbol Period Threshold 0 symbols 11: Frame Window 0 seconds 12: Frame Threshold 0 frames 13: Frame Period Window 0 second < 0 frames> 14: Frame Period Threshold 0 frames 15: Frame Seconds Summary Window 0 seconds 16: Frame Seconds Summary Threshold 0 seconds
Enter Choice, Previous Screen(0), (H)elp, E(x)it >

4.3.6 Port VLAN The flow of data on the module is controlled by configuring the Port VLAN settings. The block diagram illustrates the flow of both the management traffic and the data traffic for a plug-in module (standalone modules do not have backplane access). The data traffic is controlled by a switch matrix which provides complete control of the data traffic. The management traffic is simply enabled or disabled at each port. By default traffic flows between all ports on the module. Using the Port VLAN settings, data will only be forwarded across the enabled path, unless blocked by one of the other features (Port Access or Tag VLAN). Secure OAM and ah OAM Management data will pass to and from the Management port even if the path has been “disabled”. This allows OAM maintenance functions to always be enabled. Port VLAN control is inactive when Tag VLAN processing is turned on.


Port VLAN is access by selecting options 11 - 20 or 11 - 13 depending on the module type; plug-in or standalone.
Module - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Port VLAN Path Setup Slot Number = 11 Model Number = 8919-0 11: Fiber to UTP Enable On 12: Fiber to BP A Enable On Port Access Control Setup 13: Fiber to BP B Enable On 14: UTP to BP A Enable On 1: Fiber Enable On 15: UTP to BP B Enable On 2: UTP Enable On 16: BP A to BP B Enable On 17: Fiber to Mngmnt Enable On Enhanced Features 18: UTP to Mngmnt Enable On 19: BP A to Mngmnt Enable On 3: 802.1Q Processing Enable Off 20: BP B to Mngmnt Enable On 4: Configure Tag VLAN Control 5: Configure VLAN Membership Bandwidth Control 6: Save TAG VLAN parameters 7: Configure 802.3ah parameters 21: Ingress rate Fiber No Limit 8: Configure 802.3ah events 22: Egress rate Fiber No Limit 9: SFP Information 23: Ingress rate UTP No Limit 10: cNode Loopback 24: Egress rate UTP No Limit
Enter Choice, Previous Screen(0), (H)elp, E(x)it >
Module - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Port VLAN Path Setup Slot Number = 11 Model Number = 8919-0 11: Port1 to Port2 Enable On 12: Port1 to Mngmnt Enable On Port Access Control Setup 13: Port2 to Mngmnt Enable On 1: Fiber Enable On Bandwidth Control 2: UTP Enable On 14: Ingress rate Fiber No Limit Enhanced Features 15: Egress rate Fiber No Limit 16: Ingress rate UTP No Limit 3: 802.1Q Processing Enable Off 17: Egress rate UTP No Limit 4: Configure Tag VLAN Control 5: Configure VLAN Membership 6: Save TAG VLAN parameters 7: Configure 802.3ah parameters 8: Configure 802.3ah events 9: SFP Information 10: cNode Loopback
Enter Choice, Previous Screen(0), (H)elp, E(x)it >

4.3.7 Tagged VLAN The 10/100M supports the IEEE 802.1Q tag VLAN packet tagging and un-tagging and the 802.1p Quality of Service priority standards. The following parameters are configured for each port:
4.3.7.1 Port Priority (PRI) This (IEEE 802.1p based) user-specified value of 0 through 7 can be assigned as a QoS priority level (0 being lowest and 7 being highest) to packets ingressing (entering) a port. If no value is specified by the user, a default priority value of “0” is assigned. The PRI value is always assigned to all untagged packets. Tagged packets are assigned the PRI value when the “PVID” option is selected in the “Tagged Packet Use” section.
4.3.7.2 Port VLAN ID (PVID) This (IEEE 802.1Q based) user-specified value of 0 through 4094 can be assigned as a Port VLAN ID (PVID) to packets ingressing a port. If no value is specified by the user a default PVID value of “2” is assigned. The PVID value is always assigned to untagged packets. Tagged packets are assigned the PVID value when the “PVID” option is selected in the “Tagged Packet Use” section.
4.3.7.3 Tagged Packet Use This section defines how tagged packets ingressing a port are processed. Selecting the “PVID” option causes the PRI and PVID user-specified values to be used as the packet’s VLAN ID (VID) for processing of the packet. Selecting the “TVID” (Tagged VLAN ID) option causes the packet’s original Tag VLAN ID (TVID) and priority level to be used as the packet’s VLAN ID (VID) for processing of the packet. NOTE:Untagged packets are always assigned the port’s PRI and PVID values as their VID.
4.3.7.4 Ingress Security This section selects the ingress security level of a port. Selecting the “Low” option allows any packet to ingress a port. Selecting the “High” option allows only packets that are assigned a VLAN ID (VID) value of which this port is a member (according to the Membership Table) to ingress a port.
4.3.7.5 Egress Policy This section defines the egress policy. Selecting the “untag” option defines how a tagged or untagged packet is processed. A tagged packet will have the top tag removed and an untagged packet will be passed unmodified. Selecting the “tag” option will tag an untagged packet with the PVID and PRI of the ingress port or add a tag to an already tagged packet with the PVID and PRI of the ingress port. Selecting the “pass” option, a packet tagged or untagged will be passed unchanged as it egresses out of the port.

Tagged VLAN is accessed by selecting option 4 from the Port configuration screen. The Tag VLAN Control screen will be displayed.
Tag VLAN Control - iConverter 10/100M iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8919-0
Fiber1: Port Priority (PRI) 0 BP B 16: Port Priority (PRI) 0 2: PVID (Port VLAN ID 2 17: PVID (Port VLAN ID) 2 3: Tagged Packets Use PVID 18: Tagged Packets Use PVID 4: Ingress Security Low 19: Ingress Security Low 5: Egress Policy Pass 20: Egress Policy Pass
UTP 6: Port Priority (PRI) 0 Mngmnt 21: Port Priority (PRI) 0 7: PVID (Port VLAN ID) 2 22: PVID (Port VLAN ID) 2 8: Tagged Packets Use PVID 23: Tagged Packets Use PVID 9: Ingress Security Low 24: Ingress Security Low 10: Egress Policy Pass 25: Egress Policy Pass
BP A 11: Port Priority (PRI) 0 12: PVID (Port VLAN ID) 2 13: Tagged Packets Use PVID 14: Ingress Security Low 15: Egress Policy Pass
Enter Choice, Previous Screen(0), (H)elp, E(x)it >
Tag VLAN Control - iConverter 10/100M iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8919-0
Fiber 1: Port Priority (PRI) 0 2: PVID (Port VLAN ID) 2 3: Tagged Packets Use PVID 4: Ingress Security Low 5: Egress Policy Pass
UTP 6: Port Priority (PRI) 0 7: PVID (Port VLAN ID) 2 8: Tagged Packets Use PVID 9: Ingress Security Low 10: Egress Policy Pass
Mngmnt 11: Port Priority (PRI) 0 12: PVID (Port VLAN ID) 2 13: Tagged Packets Use PVID 14: Ingress Security Low 15: Egress Policy Pass
Enter Choice, Previous Screen(0), (H)elp, E(x)it >

4.3.8 VLAN Membership Table The VLAN Membership Table lists the permitted VLAN ID (VID) for each egress port on the module. Only packets that are assigned a VID value that matches one of the egress port’s VID memberships are allowed to egress through the port. When the Ingress Security is set to High for a specific port, the membership table is used to list the VIDs of the packets that are allowed to ingress that port. VLAN Membership is accessed by selecting option 5 from the Port configuration screen. The VLAN Membership screen will be displayed.
VLAN Membership - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Slot Number = 1 Model Number = 8919-0
VLAN ID (VID) Fiber UTP BP A BP B Mngmnt
Add new entry (a), Delete entry (d), Edit entry (e), Clear table (c)
Enter Choice, Previous Screen(0), (H)elp, E(x)it >
VLAN Membership - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Slot Number = 1 Model Number = 8919-0
VLAN ID (VID) Fiber UTP Mngmnt
Add new entry (a), Delete entry (d), Edit entry (e), Clear table (c)
Enter Choice, Previous Screen(0), (H)elp, E(x)it >

Initially the table is empty. To configure the ports with VLAN IDs, select option (a) from the VLAN Membership configuration screen.
Membership Entry - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Slot Number = 1 Model Number = 8919-0
VLAN Table Membership Entry 1
Enter Choice, Previous Screen(0), (H)elp, E(x)it >
Membership Entry - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Slot Number = 1 Model Number = 8919-0
VLAN Table Membership Entry 1
Enter Choice, Previous Screen(0), (H)elp, E(x)it >

To add a VLAN ID to the membership table, select option 1 and enter the ID #. To associate the VLAN ID to a port, select the appropriate port option (2 - 6 or 2 - 4) depending on the module type; plug-in or standalone.
Membership Entry - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Slot Number = 1 Model Number = 8919-0
VLAN Table Membership Entry 1
+1: VLAN ID 100 +2: Fiber Port Membership Yes 3: UTP Port Membership No 4: BP A Port Membership No 5: BP B Port Membership No 6: Mngmnt Port Membership No
Enter Choice, Previous Screen(0), (H)elp, E(x)it >
Membership Entry - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Slot Number = 1 Model Number = 8919-0
VLAN Table Membership Entry 1
+1: VLAN ID 100 +2: Fiber Port Membership Yes 3: UTP Port Membership No 4: Mngmnt Port Membership No
Enter Choice, Previous Screen(0), (H)elp, E(x)it >

Once all the VLAN IDs have been assigned, select option 7 or 5 to save the entries.
VLAN Membership - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Slot Number = 1 Model Number = 8919-0
VLAN ID (VID) Fiber UTP BP A BP B Mngmnt
Add new entry (a), Delete entry (d), Edit entry (e), Clear table (c)
Enter Choice, Previous Screen(0), (H)elp, E(x)it >
The VLAN membership entries are saved from the Port configuration screen, option 4.
4.3.9 cNode Loopback The 10/100M has implemented Iometrix cNode Level 1 agent for testing performance metrics. The agent recognizes measurement packets and loops them back to the sending cNode device. Iometrix cNode equipment is required to obtain performance metrics. cNode configuration is accessed by selecting option 10 from the Port configuration screen.
cNode Control -iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Slot Number = 2 Model Number = 8919-0
Enter Choice, Previous Screen(0), (H)elp, E(x)it >
From the menu, loopback can be enabled or disabled and the rate limit can be selected.

4.3.10 Port Statistics The 10/100M module provides port statistics on both the fiber and UTP port. The Port Statistics can be viewed by selecting option P from the Module configuration screen.
Module - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Switch ON Condition OFF Condition H/W Actual Slot Number = 1 1: Pause Enabled Pause Disabled Off Off Model Number = 8919-0 2: Fiber HDX Fiber FDX Off Off 3: UTP Manual UTP Auto-Neg Off Off Serial Number = xxxxxxxx 4: UTP 10 Mbps UTP 100 Mbps Off Off Manufacturing Date = xxxxxxxx 5: UTP HDX UTP FDX Off Off Product Revision = x 6: Link Propagate Link Segment Off Off Software Revision = xx 7: Remote Fault Normal Off Off 8: Symm Fault Det Normal Off Off LED 9: BP A Enabled BP A Disabled On On 1: Power = On 10: BP B Enabled BP B Disabled On On 2: Power Supply 1 = Off 11: Not Available 3: Power Supply 2 = Off 12: Slave Only Master/Slave Off Off 4: Power Supply 3 = Off 13: Not Available 5: Fiber Link = Off 14: Not Available 6: BP Master = On 15: Not Available 7: UTP 10 Link = Off 16: Not Available 8: UTP 100 Link = Off OAM settings: 9: UTP FDX = Off 17: IP Protocol State On 18: Management Mode Secure OAM Toggle Switch(1-16), (I)dentifier, (R)eset, (H)elp, (P)ortStat, Port(C)tl > P
Port Statistic Module - iConverter 10/100M iConverter, Serial Agent Identifier -
Chassis Number = 1 Slot Number = 1 Model Number = 8919-0
Fiber UTP Rx Bytes 0 0 Rx Packets 0 0 Rx Total Packets 0 0 Tx Bytes 0 0 Tx Packets 0 0
Enter Choice, Previous Screen(0), (H)elp, E(x)it >
To refresh the Port Statistic screen, press .
Port Statistics

Plug-in Module Standalone Tabletop Standalone Wall-Mount
Description 10/100BASE-TX UTP to 100BASE-FX Fiber Media Converter with integrated management
Protocols 10BASE-T, 100BASE-TX,100BASE-FX with 1536 bytes max. frame size
UTP EIA/TIA 568A/B, Category 5 and higher
Serial RS-232, 22 to 24 AWG, 12 to 50 pF/ft.
SC
Serial Mini DIN-6 female, mini DIN-6 male to DB-9 female adapter included
Controls DIP-Switches and LEDs
802.1p Priority Levels and VID Priority Level Groups
4 Levels (PRI 0-1, 2-3, 4-5, 6-7)
DC Power 1.0A @ 3.3VDC Nominal: 0.6A @ 9VDC Voltage Range: 8 - 15VDC
DC Power Connector Power supplied by backplane 2.5mm Barrel Connector or Terminal Connector
AC Power Adapter [US] N/A 100-120VAC/60Hz 0.07A @ 120VAC
AC Power Adapter [Universal]
N/A 100-240VAC/50-60Hz 0.07A @ 120VAC
Dimensions W: 2.8" x D: 4.5 "x H: 0.85" W: 3.1" x D: 4.8" x H :1.0" W: 3.8" x D: 4.8" x H: 1.0"
without power adapter 8 oz. 1 lb.
with power adapter N/A 1.5 lb.
Compliance UL, CE, FCC Class A
IP-Based Management Telnet; SNMPv1, SNMPv2c, SNMPv3
Operational - Commercial 0 to +50oC
Operational - Wide Range -40 to +60oC
Operational - Extended -40 to +75oC
Storage -40 to +80oC
Humidity (non-condensing) 5 to 95%
Altitude (Operational) -100m to 4,000m
without power adapter 600,000
with power adapter [US] N/A 250,000
with power adapter [Unv] N/A 100,000

6.1 OVERVIEW The 10/100M module has several LED indicators available to assist in the determination of problems. Refer to Section 3.5, Verify Operation, for LED definitions.
Problem: The Power LED does not illuminate after installation is complete or no LED indicators are ON
Possible Causes: A. For standalone modules, confirm that the power supply is connected to both the module and the AC or DC power source. If Power LED is still not illuminated, use a voltmeter and check the voltage of the power source (AC/DC converter used with the standalone unit should measure between 8 -15 VDC no load at the barrel connector). B. For plug-in module, confirm that the chassis is connected to an AC or DC power source. If the Power LED is still not illuminated, remove the module and verify the operation of other modules in the chassis. If power is present and the module will not turn ON, replace the module. C. The plug-in module requires ~ 3.3 watts (3.3VDC @ 1.0 amps) for normal operation. The AC Power Supply in a 19-Module Chassis can supply ~ 60 watts (3.3VDC @ 18amp). A fully loaded 19-Module chassis of 10/100M modules will require two power supplies for standard operation. This condition will cause the power LED not to illuminate.
Problem: The Fiber Optic link LED does not illuminate after installation is complete.
Possible Causes: A. Verify the Link Mode selection is set to Link Segment (LS). Until a stable link is established, leave the Link Mode configured for LS. After a Link presence is established, the Link Mode selection can be modified. B. Confirm that the fiber optic cable is properly connected to the iConverter 10/100M and the remote fiber optic device. Connecting the fiber between the Tx of the far end to the Rx on the near end will cause the P1 LED on the near end to illuminate (only when the link mode is configured for Link Segment). Completing the connection will cause the far end P1 LED to illuminate. C. Confirm that the fiber cable type matches the fiber transceiver type (multimode, single-mode) on the iConverter 10/100M. D. If using a dual-fiber model, confirm that the transmitter (Tx) is attached to the receiver side of its link partner, and that the receiver (Rx) is attached to the transmitter. A optical power meter will assist in determining which cable should be connected to the Tx and Rx of the module. To insure proper operation, a minimum of -30dBm must be present at the fiber optic receiver. E. If using a single-fiber model, confirm that the Tx wavelength on the iConverter 10/100M matches the Rx of the connected fiber optic device. Single-fiber units transmit and receive at different wavelengths (1510nm/1310nm). Verify the model numbers to insure proper compatibility.
Problem: The UTP link LED does not illuminate after installation is complete.

Possible Causes: A. Confirm that the UTP cable is connected properly to the iConverter 10/100M and the attached UTP device. Once a connection has been established between the iConverter and its link partner (switch or workstation), the UTP “10/100” LED should illuminate. If the LED does not illuminate, check the Link Mode configuration. A link mode other than Link Segment may cause the UTP “10/100” LED not to turn ON. B. Verify the iConverter 10/100M UTP port is configured with the proper settings based on the attached device (AN or MAN, 10 or 100, HD or FD). C. Verify the distance between the iConverter and the link partner is within 100 meters. D. Confirm that the UTP cable pin-out is correct (EIA/TIA-568-A). The module has auto-crossover capability, so it will accept either a straight-through or crossover cable.

7.0 WARRANTY This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment. TO REGISTER, COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM TO THE INDICATED ADDRESS. Or you may register your product on the Internet at http://www.omnitron- systems.com. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective. For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated US address using Omnitron’s standard shipping method.
Limitation of Warranty The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer-supplied interfacing, unauthorized modifications or tampering with equipment (including removal of equipment cover by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance. No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose.
Exclusive Remedies The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory.
949-250-6510 tel 949-250-6514 fax
email: [email protected] web: www.omnitron-systems.com
041-08900-001 D 7/08
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.