LV850 LEVEL SENSOR 1 Description Level Sensor LV850 is suitable for liquids with low relative dielectric constant ε r (e.g. oil). Units come with Minimum and Maximum selector switch. It operates on the principle of electrical capacitance changes arising when an electrode surrounded by air is immersed in the medium.
LV850 LEVEL SENSOR 2 Technical Data Temperature range -20°C to +130 °C (-4°F to +266°F) short-time to +150°C (+302°F) Ambient temperature -20°C to +85°C (-4°F to +185°F) Pressure resistance max. 25 bar (367.5 PSI) Response delay approx. 0.1 s Degree of protection IP 65 Input voltage DC 9 .
LV850 LEVEL SENSOR 3 Level Sensor Installation The Level Sensor may be installed in any attitude. 1. Ensure sufficient clearance space (see Fig. 1) in the container wall. • Ensure a type 3/4" NPT or G3/4A thread in the container wall has been provided.
LV850 LEVEL SENSOR 4 Connection Check that the supply voltage corresponds with the voltage rating shown on the system. 1. Loosen the gland (PG7)(see Fig. 1). 2. Unscrew the cover of the housing (C). 3. Feed the supply cable through the gland (PG7) and the cover (C), or through the metal coupling supplied as option (see Fig.
LV850 LEVEL SENSOR 7. Increase the level until the Level Sensor is immersed in the medium. 8. Minimum Sensor: • Turn the potentiometer screw (E) to (-) until the LED (green) extinguishes. Then slowly turn to (+) until the LED indicates. Adjust the screw a further full turn to (+) to compensate for any tolerance.
LV850 LEVEL SENSOR NOTES: 6.
WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
Where Do I Find Ever ything I Need for Process Measurement and Contr ol? OM EGA…Of Course! Shop online at www .omega.com TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Pa.
An important point after buying a device Omega Vehicle Security LV850 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Omega Vehicle Security LV850 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Omega Vehicle Security LV850 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Omega Vehicle Security LV850 you will learn all the available features of the product, as well as information on its operation. The information that you get Omega Vehicle Security LV850 will certainly help you make a decision on the purchase.
If you already are a holder of Omega Vehicle Security LV850, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Omega Vehicle Security LV850.
However, one of the most important roles played by the user manual is to help in solving problems with Omega Vehicle Security LV850. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Omega Vehicle Security LV850 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center